Stratos Pro A4... MSCOND

Size: px
Start display at page:

Download "Stratos Pro A4... MSCOND"

Transcription

1 Stratos Pro A4... MSCOND Instruction Manual Latest Product Information:

2 Warranty Warranty Defects occurring within 3 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender). Sensors, fittings, and accessories: 1 year. Subject to change without notice. Return of Products Under Warranty Please contact our Service Team before returning a defective device. Ship the cleaned device to the address you have been given. If the device has been in contact with process fluids, it must be decontaminated/disinfected before shipment. In that case, please attach a corresponding certificate, for the health and safety of our service personnel. Disposal Please observe the applicable local or national regulations concerning the disposal of waste electrical and electronic equipment. 2

3 Documents Supplied CD-ROM Complete documentation: Instruction manuals Safety instructions Short instructions Stratos Pro Series Safety Instructions Safety Information In official EU languages and others. ATEX / IECEX / FM / CSA EC Declarations of Conformity Stratos Pro A211 / A411 Short Instructions...3 Kurzübersicht QuickStart Быстрый старт Inicio rápido Início rápido Guida rapida Snabbstart QuickStart Other languages: Short Instructions In German, English, French, Russian, Spanish, Portuguese, Swedish, and Dutch. More languages on CD-ROM and on our website: Installation and commissioning Operation Menu structure Calibration Error messages and recommended actions Specific Test Report 3

4 Contents Documents Supplied... 3 Introduction... 7 Intended Use... 7 Safety Information... 8 Safety Precautions for Installation... 9 Overview of Stratos Pro A4... MSCOND...10 Assembly...11 Package Contents...11 Mounting Plan, Dimensions...12 Pipe Mounting, Protective Hood...13 Panel Mounting...14 Installation...15 Installation Instructions...15 Rating Plates / Terminal Assignments...16 Power Supply, Signal Lines...17 Connection of Memosens Sensor...19 Protective Wiring of Relay Contacts...20 User Interface, Keypad...22 Display...23 Signal Colors (Display Backlighting)...23 Measuring Mode...24 Selecting the Mode / Entering Values...25 Operating Modes...26 Menu Structure of Modes and Functions...27 HOLD Mode...28 Alarm...29 Configuration...30 Menu Structure of Configuration...30 Parameter Set A/B

5 Contents Configuration (Original for Copy)...38 Sensor...42 Current Output Current Output Temperature Compensation...56 Alarm Settings...60 Limit Function...62 Pulse Length / Pulse Frequency Controller...71 Controller...72 WASH Contact...76 Time and Date...78 Tag Number...78 Digital Sensors...80 Operation...80 Connecting a Digital Sensor...81 Sensor Replacement...82 Calibration...85 Selecting a Calibration Mode...85 Calibration with Calibration Solution...86 Calibration by Entry of Cell Constant...88 Product Calibration...89 Temp Probe Adjustment...91 Measurement...92 Diagnostics...95 Service USP Function Operating States Product Line and Accessories Specifications Calibration Solutions

6 Contents Concentration Curves Error Handling Error Messages Sensoface FDA 21 CFR Part Electronic Signature Passcodes Audit Trail Index Trademarks Passcodes

7 Introduction Intended Use Stratos Pro A4... MSCOND is used for measurement of electrical conductivity and temperature in liquids. Fields of application are: biotechnology, chemical industry, environment, food processing, water/waste-water treatment. The sturdy molded enclosure can be fixed into a control panel or mounted on a wall or at a post. The protective hood, which is available as accessory, provides additional protection against direct weather exposure and mechanical damage. The device has been designed for Memosens sensors. Plain-text messages in a large, backlit display allow intuitive operation. The colored display backlighting signals alarm messages (red) or HOLD mode (orange). The Sensocheck automatic monitoring of sensor and cables and the Sensoface function for clear indication of the sensor condition provide excellent diagnostics. The internal logbook (TAN SW-A002) can handle up to 100 entries up to 200 with AuditTrail (TAN SW-A003). The device provides two parameter sets which can be switched manually or via a control input for different process adaptations or different process conditions (e.g. beer and CIP). Password protection for granting access rights during operation can be configured. Two floating, digital control inputs ( Hold and Control ) are available for external control. The internal PID process controller can be configured as pulse length or pulse frequency controller. The device provides two current outputs (for transmission of measured value and temperature, for example) and four floating relay contacts. A time-controlled cleaning function can be configured. Current is provided through a universal power supply V AC/ DC, AC: Hz. Approvals for Measurement in Hazardous Locations: Stratos Pro A4...B MSCOND: acc. to FM and CSA in Class I Div 2 / Zone 2 7

8 Safety Information Safety information Be sure to read and observe the following instructions! The device has been manufactured using state of the art technology and it complies with applicable safety regulations. When operating the device, certain conditions may nevertheless lead to danger for the operator or damage to the device. See also separate document: Safety Instructions. (EC Declaration of Conformity, FM, CSA Certificates) CAUTION! Commissioning must only be performed by trained personnel authorized by the operating company! Whenever it is likely that protection has been impaired, the device shall be made inoperative and secured against unintended operation. The protection is likely to be impaired if, for example: the device shows visible damage the device fails to perform the intended measurements after prolonged storage at temperatures above 70 C after severe transport stresses Before recommissioning the device, a professional routine test must be performed. This test must be carried out at the manufacturer's factory. Please note: Before commissioning it must be proved that the device may be connected with other equipment. 8

9 Safety Information Safety Precautions for Installation The electrical installation shall conform to the national regulations for electrical installations and/or other applicable national or local codes or regulations. The power supply shall be disconnectable from the device by a two-poled circuit breaker. Switch and circuit breaker shall be located in close proximity to the equipment and be easily accessible by the OPERATOR. They shall be marked as disconnect switch for the device. Be sure to disconnect the mains supply and any relay contacts which are connected to separate current sources before starting maintenance operations. Approvals for application in hazardous locations Stratos Pro A4...B MSCOND: acc. to FM and CSA in Class I Div 2 / Zone 2 (pending). See also separate Safety Instructions document. Terminals: Screw terminal, suitable for single wires / flexible leads up to 2.5 mm 2 (AWG 14). Recommended torque for the terminal screws: Nm. Important Notice: The operator must indicate the type of protection! When the device provides different types of protection, the operator must specify the applied type of protection during installation. To do so, use the checkboxes on the rating plate: Additional rating plate at outside bottom of front with checkboxes for marking the respective application after installation 9

10 Overview Overview of Stratos Pro A4... MSCOND Supply 1 RS 485 Output Output 1/HART RS 485 A 2 10 Output 1 / HART RS 485 B 3 Output Output 2 GND/Shield 4 8 Output 2 R1 14 REL 1 15 REL 1/2 R2 16 REL 2 Input + 5 Current Alarm 17 Alarm Input 6 input R3 18 Alarm Wash 19 Wash HOLD HOLD / CONTROL CONTROL HOLD input Control input R4 Power Wash Power Power 10

11 Assembly Package Contents Check the shipment for transport damage and completeness! The package should contain: Front unit, rear unit, bag containing small parts Specific test report Documentation (cf Pg 3) CD-ROM Fig.: Assembling the enclosure 1) Jumper (3 x) 2) Washer (1 x), for conduit mounting: Place washer between enclosure and nut 3) Cable tie (3 x) 4) Hinge pin (1 x), insertable from either side 5) Enclosure screw (4 x) 6) Sealing insert (1 x) 7) Rubber reducer (1 x) 8) Cable gland (3 x) 9) Filler plug (3 x) 10) Hexagon nut (5 x) 11) Sealing plug (2 x), for sealing in case of wall mounting 11

12 Assembly Mounting Plan, Dimensions ) Cable gland (3 x) 2) Knockouts for cable gland or ½" conduit, 21.5 mm dia. (2 knockouts) Conduits not included! 3) Knockout for pipe mounting (4 x) 4) Knockout for wall mounting (2 x) Fig.: Mounting plan (All dimensions in mm!) 12

13 Pipe Mounting, Protective Hood Assembly ø40...ø ) Hose clamp with worm gear drive to DIN 3017 (2 x) 2) Pipe-mount plate (1 x) 3) For vertical or horizontal posts or pipes 4) Self-tapping screw (4 x) 4 Fig.: ZU 0274 pipe-mount kit (All dimensions in mm!) Fig.: ZU 0737 protective hood for wall and pipe mounting (All dimensions in mm!) 13

14 Assembly Panel Mounting < ) Circumferential sealing (1 x) 2) Screw (4 x) 3) Position of control panel 4) Span piece (4 x) 5) Threaded sleeve (4 x) Cutout 138 x 138 mm (DIN 43700) Fig.: ZU 0738 panel-mount kit (All dimensions in mm!) 14

15 Installation Installation Instructions Installation of the device must be carried out by trained experts in accordance with this instruction manual and as per applicable local and national codes. Be sure to observe the technical specifications and input ratings during installation! Be sure not to notch the conductor when stripping the insulation! Before connecting the device to the power supply, make sure that its voltage lies within the range 20.5 to 253 V AC/DC! The supplied current must be galvanically isolated. If not, connect an isolator module. All parameters must be set by a system administrator prior to commissioning! Terminals: suitable for single wires / flexible leads up to 2.5 mm 2 (AWG 14) Additional safety precautions have to be taken for operation in h azardous locations FM, CSA Cl. I Div 2 / Zone 2! (See separate Safety Instructions document.) 15

16 Installation Rating Plates / Terminal Assignments Fig.: Terminal assignments of Stratos Pro A4... Fig.: Stratos Pro A401N-MSCOND rating plate at bottom of front Fig.: Stratos Pro A411N-MSCOND rating plate at bottom of front Fig.: Example of additional approval plate (ccsaus, FM) The specifications refer to the respective device. Important Notice: The operator must indicate the type of protection! When the device provides different types of protection, the operator must specify the applied type of protection during installation. 16

17 Power Supply, Signal Lines Connect the power supply for Stratos Pro A401/A411 COND to terminals 21 and 22 ( V AC, Hz / V DC) 1 Areas for placing the screwdriver to pull out the terminals 22 Terminal assignments 1supply 2 RS 485 A 3 RS 485 B 4 GND/shield 5 + input 6 input 7 + out 2 8 out out 1/HART 10 out 1/HART 11 hold 12 hold/control 13 control 14 REL 1 15 REL 1/2 16 REL 2 17 alarm 18 alarm 19 wash 20 wash 21 power 22 power Fig.: Terminals, device opened, back of front unit 17

18 Wiring Example Measuring task: Conductivity, temperature Sensor:Memosens Caution! Connection to RS-485 interface! The measuring module slot must be empty*! Sensor Brown Green Yellow White Shield Cable Device The Memosens sensor is connected to the RS-485 interface of the device. When the sensor is selected in the Configuration menu, the default values are taken as calibration data. They can then be modified by calibration. *)Stratos Pro A2... MSCOND is intended for connecting a Memosens sensor via RS-485 interface. It does not provide a measuring module. 18

19 Connection of Memosens Sensor Areas for placing the screwdriver to pull out the terminals HART Memosens connection: Wire color 1 Supply Brown 2 RS 485 A Green 3 RS 485 B Yellow 4 GND/shield White, transparent shield 19

20 Protective Wiring of Relay Contacts Protective Wiring of Relay Contacts Relay contacts are subject to electrical erosion. Especially with inductive and capacitive loads, the service life of the contacts will be reduced. For suppression of sparks and arcing, components such as RC combinations, nonlinear resistors, series resistors, and diodes should be used Typical AC applications with inductive load 1 Load 2 RC combination, e.g. RIFA PMR 209 Typical RC combinations for 230 V AC: capacitor 0.1 µf / 630 V, resistor 100 Ω / 1 W 3 Contact 20

21 Protective Wiring of Relay Contacts Typical Protective Wiring Measures A: DC application with inductive load B: AC/DC applications with capacitive load C: Connection of incandescent lamps A1 A2 A3 B1 B2 B3 C1 C3 Inductive load Free-wheeling diode, e.g. 1N4007 (Observe polarity) Contact Capacitive load Resistor, e.g. 8 Ω / 1 W at 24 V / 0.3 A Contact Incandescent lamp, max 60 W / 230 V, 30 W / 115 V Contact WARNING! Make sure that the maximum ratings of the relay contacts are not exceeded even during switching! 21

22 User Interface, Keypad IrDA transmitter/receiver 2 Display 3 Keypad 4 Rating plate (bottom) 4 Key meas info Arrow keys up / down Arrow keys left / right Function Return to last menu level Directly to measuring mode (press > 2 s) Retrieve information Show error messages Configuration: Confirm entries, next configuration step Calibration: Continue program flow Measuring mode: Display output current Measuring mode: Call menu Menu: Increase/decrease a numeral Menu: Select Measuring mode: Call menu Menu: Previous/next menu group Number entry: Move between digits 22

23 Display Temperature 2 Sensocheck 3 Interval/response time 4 Sensor data 5 Not used 6 Limit values 7 Alarm 8 Service 9 Parameter sets A/B 10 Calibration 11 Digital sensor 12 Waiting time running Info available 14 HOLD mode active 15 Main display 16 Secondary display 17 Proceed with 18 Not used 19 Diagnostics 20 Configuration mode 21 Calibration mode 22 Measuring mode 23 Sensoface 24 Measurement symbol Signal Colors ( Display Backlighting) Red Orange Turquoise Green Purple Alarm HOLD mode (Calibration, Configuration, Service) Diagnostics Info Sensoface message 23

24 Measuring Mode After the operating voltage has been connected and the sensor identified, the device automatically goes to Measuring mode. To call the measuring mode from another operating mode (e.g. Diagnostics, Service): Hold meas key depressed (> 2 s). Sensoface indicator (sensor status) Active parameter set Time Mode indicator (measuring) Hold meas key depressed to call the measuring mode (pressing once more switches the display) Process variable Temperature key In measuring mode the display indicates: Measured value and time (24/12 h AM/PM) as well as temperature in C or F (formats selected during configuration) By pressing the meas key in measuring mode you can view the following displays (for approx. 60 sec): Measured value and selection of parameter set A/B (if set to Manual ) Measured value and tag (point of measurement designation ed during configuration) Time and date Controller (if configured), upper display: controller output Y, lower display: Setpoint Pressing the key shows the output currents. They are displayed as long as is held depressed, then the measured-value display will return after 3 sec. The device must be configured for the respective measurement task! 24

25 Selecting the Mode / Entering Values To select the operating mode: 1) Hold meas key depressed (> 2 s) (directly to measuring mode) 2) Press any arrow key: the selection menu appears 3) Select operating mode using left / right arrow key 4) Press to confirm the selected mode Selection menu Selected mode (blinks) To a value: 5) Select numeral: left / right arrow key 6) Change numeral: up / down arrow key 7) Confirm entry by pressing

26 Operating Modes Diagnostics Display of calibration data, display of sensor data, performing a device self-test, viewing the logbook entries, display of hardware/software versions of the individual components. The logbook can store 100 events ( ). They can be displayed directly on the device. The logbook can be extended to 200 entries using a TAN (Option). HOLD Manual activation of HOLD mode, e.g. for servicing. The signal outputs adopt a defined state. Calibration Every sensor has typical characteristic values. Calibration is required to supply a correct measured value. The device checks which value the sensor delivers when measuring in a known solution. When there is a deviation, the device can be adjusted. In that case, the device displays the actual value and internally corrects the measurement error of the sensor. During calibration the device is in HOLD mode. During calibration the analyzer remains in the HOLD mode until it is stopped by the operator. Configuration The analyzer must be configured for the respective measurement task. In the Configuration mode you select the connected sensor, the measuring range to be transmitted, and the conditions for warning and alarm messages. During configuration the device is in HOLD mode. Configuration mode is automatically exited 20 minutes after the last keystroke. The device returns to measuring mode. Service Maintenance functions (current source, relay test, controller test), IrDA operation, passcode assignment, reset to factory settings, enabling of options (TAN). 26

27 Menu Structure of Modes and Functions Measuring mode meas meas TAG display after 60 s meas Display controller CLK display parameters after 60 s (if configured) meas Pressing any arrow key opens the selection menu. Select the menu group using the left/right arrow keys. Press to open a menu. Press meas to return. Display of calibration data Display of sensor data Self test: RAM, ROM, EEPROM, module Logbook: 100 events with date and time Display of direct, uncorrected sensor signals Display of software version, model designation, serial number Manual activation of HOLD mode, e.g. for sensor replacement. The signal outputs behave as configured (e.g. last measured value, 21 ma) Calibration with calibration solution Calibration by entry of cell constant Product calibration Adjustment of temperature probe Configuring parameter set A (Access via code, factory setting: 5555) Configuring parameter set B Display of measured values for validation (simulators) Current source, output 1 Current source, output 2 Relay test Controller: manual specification of controller output Activating the IrDA interface Specifying access codes for operating modes Reset to factory setting Enabling an option via TAN 27

28 HOLD Mode The HOLD mode is a safety state during configuration and calibration. Output current is frozen (Last) or set to a fixed value (Fix). Alarm and limit contacts are disabled. The HOLD mode is indicated by orange display backlighting. HOLD mode, display icon: Output Signal Response Last: The output current is frozen at its last value. Recommended for short configuration procedures. The process should not change decisively during configuration. Changes are not noticed with this setting! Fix: The output current is set to a value that is noticeably different from the process value to signal the control system that the device is being worked at. Output Signal During HOLD: Output current [ma] 21 Output signal for HOLD FIX setting = 21.0 ma Output signal for HOLD LAST setting 4 HOLD active HOLD active Terminating the HOLD Mode The HOLD mode is ended by switching to measuring mode (hold meas key depressed). The display reads Good Bye, after that, the HOLD mode is exited. When the calibration mode is exited, a confirmation prompt ensures that the installation is ready for operation (e.g.: sensor reinstalled, located in process). 28

29 Alarm External Activation of HOLD The HOLD mode can be activated from outside by sending a signal to the Hold input (e.g. from the process control system). HOLD Power supply V AC/DC 10 input Stratos Pro A4... HOLD inactive HOLD active V AC/DC V AC/DC Process control system (PCS) Manual Activation of HOLD The HOLD can be activated manually from the HOLD menu. This allows checking or replacing a sensor, for example, without provoking unintended reactions of outputs or contacts. Press meas key to return to selection menu. Alarm When an error has occurred, Err xx is displayed immediately. Only after expiry of a user-defined delay time will the alarm be registered and ed in the logbook. During an alarm the display blinks, the display backlighting turns red. Error messages can also be signaled by a 22 ma output current (see Configuration). The alarm contact is activated by alarm and power failure, see also Configuration / Alarm Settings. 2 sec after the failure event is corrected, the alarm status will be deleted. 29

30 Configuration Menu Structure of Configuration The device provides 2 parameter sets A and B. By switching between the parameter sets you can adapt the device to different measurement situations, for example. Parameter set B only permits setting of process-related parameters. The configuration steps are assigned to different menu groups. Using and you can jump between the individual menu groups. Each menu group contains menu items for setting the parameters. Pressing opens a menu item. The values are edited using and. Pressing confirms/stores the settings. Return to measurement: Press meas. Select menu group Menu group Code Display Select menu item Sensor selection Current output 1 Current output 2 Compensation Alarm mode SNS: Menu item 1... Menu item... OT1: OT2: COR: ALA: Relay outputs REL: Cleaning WSH: Setting the clock CLK: Tag number TAG: 30

31 Parameter Set A/B: Configurable Menu Groups Configuration (Some parameters are identical in A and B. They are configured in parameter set A only.) Menu group Parameter set A Parameter set B SENSOR Sensor selection --- OUT1 Current output 1 Current output 1 OUT2 Current output 2 Current output 2 CORRECTION Compensation Compensation ALARM Alarm mode Alarm mode REL 1/REL 2 Relay outputs Relay outputs WASH Cleaning --- PARSET Parameter set --- selection CLOCK Setting the clock --- TAG Tag number --- External Switchover of Parameter Sets A/B You can switch between parameter sets A and B by applying a signal to the CONTROL input. For parameter setting, see Pg 37. Max. 30 V AC/DC Control input e.g. process control system Stratos Pro A4... Parameter set A active Parameter set B active V AC/DC V AC/DC 31

32 Configuration Parameter Set A/B Manual Selection. Signaling via WASH Contact. Display Action Remark To switch between Manual selection of parameter sets: parameter sets must have been preset in CONFIG Press meas mode. Default setting is a fixed parameter set A. Wrong settings change the measurement properties! PARSET blinks in the lower line. Select parameter set using and keys Select PARSET A / PARSET B Press to confirm. Cancel by pressing meas Wash 19 Wash The active parameter set can be displayed using the WASH contact: R4 20 Wash If configured correspondingly, the WASH contact signals: Parameter set A (open contact) Parameter set B (closed contact) 32

33 Configuration Configuration Choices Default SENSOR SNS: MEMOSENS MEMOSENS 2-ELECTRODE 4-ELECTRODE 2-EL / 4-EL* CELLFACTOR 1) c c *) These sensors appear in the menu selection but can only be used with a measuring module installed. Stratos Pro A4... MSCOND is intended for connecting a Memosens sensor via RS-485 interface. It does not provide a measuring module. For information on retrofitting and the respective costs, please contact the manufacturer (see back of this manual). MEAS MODE Cond COND Conc % Sal USP μs/cm Cond MEAS RANGE 2) x.xxx μs/cm xxx.x ms/cm xx.xx μs/cm xxx.x μs/cm xxxx μs/cm x.xxx ms/cm xx.xx ms/cm xxx.x ms/cm x.xxx S/m xx.xx S/m xx.xx MΩ Conc Solution -01- (NaCl) -01- (NaCl) -02- (HCl) -03- (NaOH) -04- (H 2 SO 4 ) -05- (HNO 3 ) TEMP UNIT C / F C 1) With Memosens, the cell constant is automatically loaded from the sensor. When switching from Memosens to 2-/4-electrode sensor, the cell constant is set to the default value c and then must be ed manually. 2) The range selection allows selecting the maximum resolution. If the upper limit of this range is exceeded, the device automatically switches to the next higher range. 33

34 Configuration Configuration Choices Default SENSOR SNS TEMPERATURE AUTO MAN EXT (only if enabled via TAN) AUTO RTD TYPE 100 PT 1000 PT 8.55 NTC 30 NTC Output 1 (OUT1) OT1: RANGE 0 20 ma 4 20 ma 34 MAN TEMPERATURE C ( F) 4-20 ma CHANNEL COND/TMP COND OUTPUT (with Cond only) LIN / LOG LIN LIN LOG BEGIN 4mA (0 ma) xxxx ms/cm END 20 ma xxxx ms/cm BEGIN 4mA (0 ma) Decades AUTO 100 PT C (077.0 F) CIP COUNT ON/OFF OFF SIP COUNT ON/OFF OFF END 20 ma Decades TMP BEGIN 4mA C C (0 ma) END 20 ma C TMP BEGIN 4mA F F (0 ma) END 20 ma F FILTERTIME SEC 0000 SEC 22mA-FAIL ON/OFF OFF HOLD MODE LAST/FIX LAST FIX HOLD-FIX (0) ma ma

35 Configuration Configuration Choices Default Output 2 (OUT2) OT2: RANGE 0 20 ma 4 20 ma 4-20 ma CHANNEL COND/TMP TMP... other steps like output 1 Temperature compensation (CORRECTION) COR: TC SELECT OFF LIN NLF NaCl HCL NH3 OFF LIN TC LIQUID %/K 00.00%/K TEMP EXT ON/OFF OFF ON I-INPUT ma/ ma ma C BEGIN 4 ma C C END 20 ma C C F BEGIN 4 ma F END 20 ma F Alarm (ALARM) ALA: DELAYTIME SEC 0010 SEC SENSOCHECK ON/OFF OFF 35

36 Configuration Configuration Choices Default Relay outputs (Rel1/Rel2) REL: Selected in text line LIMITS CONTROLLER USP LIMITS RL1 CHANNEL COND/TMP COND FUNCTION Lo LEVL Lo LEVL Hi LEVL CONTACT N/O, N/C N/O LEVEL Within meas. range HYSTERESIS % full scale DELAYTIME SEC 0010 SEC RL2 CHANNEL COND/TMP COND FUNCTION Lo LEVL Hi LEVL Hi LEVL CONTACT N/O, N/C N/O LEVEL Within meas. range HYSTERESIS % full scale DELAYTIME SEC 0010 SEC CTR CHANNEL COND/TMP COND TYPE PLC / PFC PLC PULSE SEC 0010 SEC LENGTH PFC PULSE FREQ P/M 0060 P/M SETPOINT Within meas. range DEAD BAND % full scale P-GAIN % 0100% I-TIME SEC 0000SEC D-TIME SEC 0000SEC HOLD MODE Y LAST/Y OFF Y LAST 36

37 Configuration Configuration Choices Default Relay outputs (Rel1/Rel2) USP: USP FACTOR % % CONTACT REL1 N/O, N/C N/O DELAYTIME 0000 SEC CONTACT REL2 N/O, N/C N/O DELAYTIME 0000 SEC Cleaning contact (WASH) WSH: Selected in text line WASH PARSET A/B WASH WASH WASH CYCLE H h WASH TIME SEC 0060 SEC CONTACT N/O, N/C N/O Parameter set (PARSET) PAR: Select fixed parameter set (A) or switch between A/B via control input or manually in measuring mode PARSET FIX / CNTR INPUT / MANUAL PARSET FIX (fixed parameter set A) Real-time clock (CLOCK) CLK: FORMAT 24 h / 12 h 24 h TIME hh/mm : h TIME hh/mm : AM/PM: DAY/MONTH / YEAR Tag number (TAG) TAG: (Input in text line) 37

38 Configuration (Original for Copy) Default Settings of Parameter Sets Two complete parameter sets are stored in the EEPROM. As delivered, the two sets are identical but can be edited. Please note: Fill in your configuration data on the following pages or use them as original for copy. 38

39 Parameter Parameter set A Parameter set B SNS: Sensor type --- *) SNS: Cell constant --- SNS: Measuring mode --- SNS: Measuring range --- SNS: Concentration determination SNS: Temperature unit --- SNS: Temp detection --- SNS: Manual temp --- SNS: RTD type --- SNS: CIP counter --- SNS: SIP counter --- OT1: Current range OT1: Process variable OT1: LIN/LOG output OT1: Current start OT1: Current end OT1: Filter time OT1: 22 ma error current OT1: HOLD mode OT1: HOLD-FIX current Configuration (Original for Copy) --- *) These parameters cannot be adjusted in parameter set B, the values are the same as in parameter set A. 39

40 (Original for Copy) Configuration Parameter Parameter set A Parameter set B OT2: Current range OT2: Process variable OT2: LIN/LOG output OT2: Current start OT2: Current end OT2: Filter time OT2: 22 ma error current OT2: HOLD mode OT2: HOLD-FIX current COR: TC SELECT COR: Temp coefficient COR: Ext. temp input COR: Current range COR: Current start COR: Current end ALA: Delay ALA: Sensocheck on/off REL: Usage RL1: Process variable RL1: Function RL1: Contact response RL1: Setpoint RL1: Hysteresis RL1: Delay RL2: Process variable RL2: Function RL2: Contact response 40

41 Configuration (Original for Copy) Parameter Parameter set A Parameter set B RL2: Setpoint RL2: Hysteresis RL2: Delay CTR: Process variable CTR: Controller type CTR: Pulse length CTR: Pulse frequency CTR: Setpoint CTR: Neutral zone CTR: P gain CTR: I time CTR: D time CTR: HOLD mode REL: USP factor REL: RL1 contact REL: Delay REL: RL2 contact REL: Delay WSH: Contact function --- *) WSH Wash cycle --- *) WSH: Wash duration --- *) WSH: Contact response --- *) CLK: Time & Date --- *) TAG: Tag number --- *) *) These parameters cannot be adjusted in parameter set B, the values are the same as in parameter set A. 41

42 Configuration Sensor Selecting the parameters Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, press. 4 Select SENSOR menu using keys, press. 5 All items of this menu group are indicated by the SNS: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 Select sensor type Enter cell constant Select measuring mode Select range Concentration determination Temperature unit Temperature detection Select type of temp probe Cleaning cycles Sterilization cycles 5 6 meas 42

43 5 Menu item Action Choices Select sensor type Select sensor type using keys. Press to confirm. Configuration MEMOSENS 2-ELECTRODE 4-ELECTRODE Enter cell constant (not for Memosens) Modify digit using keys, select next digit using keys c ( c) Press to confirm. Select measuring mode Select desired measuring mode using keys. Press to confirm. Cond Conc % Sal USP μs/cm Select range Concentration determination For cond measurement only Select desired range using keys. Press to confirm. For conc measurement only Select desired concentration solution using keys. Press to confirm. x.xxx μs/cm, xx.xx μs/cm xxx.x μs/cm, xxxx μs/cm x.xxx ms/cm, xx.xx ms/cm xxx.x ms/cm, x.xxx S/m xx.xx S/m, xx.xx MΩ -01- (NaCl) -02- (HCl) -03- (NaOH) -04- (H2SO4) -05- (HNO3) 43

44 Configuration Sensor Select: Temperature unit, temperature detection, type of temp probe Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, press. 4 Select SENSOR menu using keys, press. 5 All items of this menu group are indicated by the SNS: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 Select sensor type Enter cell constant Select measuring mode Select range Concentration determination Temperature unit Temperature detection Select type of temp probe Cleaning cycles Sterilization cycles 5 meas 6 44

45 5 Menu item Action Choices Temperature unit C / F Select C or F using keys. Configuration Temperature detection (Manual temperature) Press to confirm. Select mode using : AUTO: Measured by sensor MAN: Direct input of temperature, no measurement (see next step) EXT: Temperature specified via current input (only if TAN E enabled) Press to confirm. Modify digit using keys, select next digit using keys. Press to confirm. AUTO MAN EXT C ( F) Select type of temp probe (not for Memosens) Select type of temperature probe using keys. 100 PT 1000 PT 30 NTC 8.55 NTC Press to confirm. 45

46 Configuration Sensor Adjust: Cleaning cycles, sterilization cycles Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, press. 4 Select SENSOR menu using keys, press. 5 All items of this menu group are indicated by the SNS: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 Select sensor type Enter cell constant Select measuring mode Select range Concentration determination Temperature unit Temperature detection Select type of temp probe Cleaning cycles Sterilization cycles 5 meas 6 46

47 5 Menu item Action Choices CIP / SIP Cleaning cycles On / Off Select ON or OFF using keys. Activates/deactivates logging in extended logbook Press to confirm. Configuration ON/OFF Sterilization cycles On / Off Select ON or OFF using keys. Activates/deactivates logging in extended logbook Press to confirm. ON/OFF Please note: A CIP or SIP cycle is only ed into the logbook 2 hours after the start to ensure that the cycle is complete. The cleaning and sterilization cycles are counted to measure the load on the sensor. Suitable for biochemical applications (process temp approx C, CIP temperature > 55 C, SIP temperature > 115 C). 47

48 Configuration Current Output 1 Output current range, process variable 1 1 Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, 2 press. 4 Select OUT1 menu using keys, press. 5 All items of this menu group are indicated by the OT1: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 3 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 Current range Process variable LIN/LOG output* Current start Current end Time averaging filter Output current during error message Output current during HOLD Output current for HOLD FIX 5 6 meas *) Selectable decades with logarithmic setting (LOG): S/cm: 1.0 µs/cm, 10.0 µs/cm, µs/cm, 1.0 ms/cm, 10.0 ms/cm, ms/cm, 1000 ms/cm S/M: S/m, 0.01 S/m, 0.1 S/m, 1.0 S/m, 10.0 S/m, 100 S/m 48

49 5 Menu item Action Choices Current range Select 4-20 ma or 0-20 ma range using keys. Configuration 4-20 ma / 0-20 ma Press to confirm. Process variable Select using keys: Cond: Conductivity TMP: Temperature Press to confirm. Then select characteristic (LIN/LOG). Cond/TMP Current start Current end Modify digit using keys, select next digit using keys. Press to confirm. Enter value using keys. Press to confirm. As selected for process variable/range If the adjusted range is exceeded, the device automatically switches to the next higher range (Autorange) As selected for process variable/range If the adjusted range is exceeded, the device automatically switches to the next higher range (Autorange) Assignment of measured values: Current start and current end Example 1: Range ms/cm Example 2: Range ms/cm [ms/cm] Advantage: Higher resolution in range [ms/cm] of interest Output current 20 [ma] Output current 20 [ma] 49

50 Configuration Current Output 1 Adjust time interval of output filter 1 1 Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, 2 press. 4 Select OUT1 menu using keys, press. 5 All items of this menu group are indicated by the OT1: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 3 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 meas 6 Current range Process variable LIN/LOG output Current start Current end Time averaging filter Output current during error message Output current during HOLD Output current for HOLD FIX 5 50

51 5 Menu item Action Choices Time averaging Enter value using SEC filter keys. (0000 SEC) Configuration Press to confirm. Time averaging filter (attenuation) To smoothen the current output, a low-pass filter with adjustable filter time constant can be switched on. When there is a jump at the input (100 %), the output level is at 63 % after the time interval has been reached. The time interval can be set from 0 to 120 sec. If the time interval is set to 0 sec, the current output directly follows the input. Please note: The filter only acts on the current output, not on the display, the limit values, or the controller! Cond Time interval s 51

52 Configuration Current Output 1 Output current during Error and HOLD 1 1 Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, 2 press. 4 Select OUT1 menu using keys, press. 5 All items of this menu group are indicated by the OT1: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 3 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 meas 6 Current range Process variable LIN/LOG output Current start Current end Time averaging filter Output current during error message Output current during HOLD Output current for HOLD FIX 5 52

53 5 Menu item Action Choices Output current during error message Select ON or OFF using keys. Press to confirm. ON/OFF Configuration Output current during HOLD Output current for HOLD FIX LAST: During HOLD the last measured value is maintained at the output. FIX: During HOLD a value (to be ed) is maintained at the output. Select using Press to confirm. Only with FIX selected: Enter current which is to flow at the output during HOLD Enter value using keys. LAST/FIX ma (21.00 ma) Press to confirm. Output Signal During HOLD: Output current [ma] Output signal for HOLD FIX setting = 21.0 ma Output signal for HOLD LAST setting 21 4 HOLD active HOLD active 53

54 Configuration Current Output 2 Output current range, process variable 1 1 Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, 2 press. 4 Select OUT2 menu using keys, press. 5 All items of this menu group are indicated by the OT2: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 3 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 meas 6 Current range Process variable LIN/LOG output Current start Current end Time averaging filter Output current during error message Output current during HOLD Output current for HOLD FIX 5 54

55 5 Menu item Action Choices Current range Select 4-20 ma or 0-20 ma range using keys. Configuration 4-20 ma / 0-20 ma Press to confirm. Process variable Select using keys: Cond: Conductivity TMP: Temperature Press to confirm. Cond/TMP Begin: 0 C End: 100 C... All the following adjustments are made as for current output 1 (see there)! 55

56 Configuration Temperature Compensation Selecting the compensation method 1 1 Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, 2 press. 4 Select CORRECTION menu using keys, press. 5 All items of this menu group are indicated by the COR: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 3 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 Temperature compensation Current input for external temperature measurement Current start Current end 5 6 meas 56

57 5 Menu item Action Choices Temperature Select desired compensation compensation using keys: Configuration OFF: Temperature compensation switched off LIN: Linear temperature compensation with entry of temperature coefficient nlf: Temperature compensation for natural waters to EN NaCl: Temperature compensation for ultrapure water with NaCl traces HCl: Temperature compensation for ultrapure water with HCl traces NH3: Temperature compensation for ultrapure water with NH 3 traces Press to confirm. 57

58 Configuration Temperature Compensation TC process medium, current input for temp measurement 1 1 Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, 2 press. 4 Select CORRECTION menu using keys, press. 5 All items of this menu group are indicated by the COR: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 3 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 Temperature compensation Current input for external temperature measurement Current start Current end 5 6 meas 58

59 5 Configuration Menu item Action Choices Temp compensation, process medium With linear compensation only: Enter temperature compensation of the process medium. Enter value using keys. Press to confirm %/K Current range Select desired range using keys ma / 0-20 ma Press to confirm. Current start Current end Modify digit using keys, select next digit using keys. Press to confirm. Enter value using keys. Input range: C / F Input range: C / F Press to confirm. 59

60 Configuration Alarm Settings Delay, Sensocheck 1 1 Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, 2 press. 4 Select ALARM menu using keys, press. 5 All items of this menu group are indicated by the ALA: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 3 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 Delay Sensocheck 5 6 meas 60

61 5 Menu item Action Choices Delay Sensocheck Enter value using keys. Press to confirm. Select Sensocheck (continuous monitoring of sensor). Select ON or OFF using keys. Press to confirm (At the same time, Sensoface is activated. With OFF, Sensoface is also switched off.) Configuration SEC (010 SEC) ON/OFF Alarm R Alarm Contact The alarm contact is closed during normal operation (N/C). It opens in the case of alarm or power outage. As a result, a failure message is provided even in the case of line breakage (fail-safe behavior). For contact ratings, see Specifications. Error messages can also be signaled by a 22 ma output current (see Error messages and Configuration Output 1/Output 2). Operating behavior of the alarm contact: see Operating States table. The alarm delay time delays the color change of the display backlighting to red, the 22 ma signal (if configured), and the alarm contact switching. 61

62 Configuration Limit Function Relay Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, 2 press. 4 Select REL1/REL2 menu using keys, press. 5 All items of this menu group are indicated by the RL1: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 3 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 meas 6 Use of relays Select process variable Limit 1 switching characteristics (function) Limit 1 contact type Limit 1 setpoint Limit 1 hysteresis Limit 1 delay 5 62

63 5 Menu item Action Choices Use of relays Select in the text line Select process variable using keys: Limit function (LIMITS) Controller (CONTROLLER) USP function (USP FUNCT.) Press to confirm. Select desired process variable using keys. Configuration LIMITS / CONTROLLER (not with Mohm as process variable!) / USP FUNCT (only with USP selected!) Please note: Selecting CONTROLLER leads to Controller menu group (CTR), selecting USP FUNCT to USP function menu group. Cond/TMP Press to confirm. Limit 1 function Limit 1 contact response Select desired function using arrow keys. LoLevel: active if value falls below / HiLevel: active if value exceeds setpoint Press to confirm. N/O: normally open contact N/C: normally closed contact Select using keys. Press to confirm. Lo LEVL / Hi LEVL N/O / N/C Limit 1 setpoint Enter setpoint using keys. Within meas. range Press to confirm. 63

64 Configuration Limit Function Relay Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, 2 press. 4 Select REL1/REL2 menu using keys, press. 5 All items of this menu group are indicated by the RL1: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 3 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 meas 6 Use of relays Select process variable Limit 1 switching characteristics (function) Limit 1 contact type Limit 1 setpoint Limit 1 hysteresis Limit 1 delay 5 64

65 5 Menu item Action Choices Limit 1 hysteresis Limit 1 delay Select hysteresis using keys. Press to confirm. The contact is activated with delay (deactivated without delay) Adjust delay using keys. Press to confirm. Configuration % full scale If the adjusted range is exceeded, the device automatically switches to the next higher range (Autorange) SEC (0010 SEC) Limit Lo Limit Hi Hysteresis + Setpoint Signal Setpoint Hysteresis - Signal Contact 1 0 Contact

66 Configuration Limit Function Relay Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, 2 press. 4 Select REL1/REL2 menu using keys, press. 5 All items of this menu group are indicated by the RL2: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 3 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 Select process variable Limit 2 switching characteristics (function) Limit 2 contact type Limit 2 setpoint Limit 2 hysteresis Limit 2 delay 5 meas 6 66

67 Menu item Action Choices Select process variable (CHANNEL) Select desired process variable using keys. Press to confirm. Cond/TMP Limit 2 function (FUNCTION) Limit 2 contact type (CONTACT) Limit 2 setpoint (LEVEL) Limit 2 hysteresis (HYSTERESIS) Limit 2 delay (DELAYTIME) Select desired function using arrow keys. Press to confirm. N/O: normally open contact N/C: normally closed contact Select using keys. Press to confirm. Enter setpoint using keys. Press to confirm. Select hysteresis using keys. Press to confirm. The contact is activated with delay (deactivated without delay) Adjust delay using keys. Press to confirm. Configuration Lo LEVL / Hi LEVL N/O / N/C Within meas. range If the adjusted range is exceeded, the device automatically switches to the next higher range (Autorange) % full scale (Autorange see above) SEC (0010 SEC) Limit Lo Limit Hi Hysteresis + Setpoint Signal Setpoint Hysteresis - Signal Contact 1 0 Contact

68 68

69 Controller Functions Typical Applications P Controller Application for integrating control systems (e.g. closed tank, batch processes). PI Controller Application for non-integrating control systems (e.g. drains). PID Controller The additional derivative action compensates for measurement peaks. Controller Characteristic Relay % Controller output Yp [%] Neutral zone Yp=0 Deviation Xw [ms/cm] Setpoint -100 % Relay 2 69

70 Controller Functions Controller Equations 1 Controller output Y = Y P + Y T P dt + T D R dy P dt P action I action D action Proportional action Y P Y Setpoint - Meas. value P = Measuring range * K C with: Y P Proportional action T R Reset time [s] T D Rate time [s] K C Controller gain [%] Neutral zone (Y=0) Tolerated deviation from desired value. With the setting 1 ms/cm, for example, a deviation of ± 0.5 ms/cm from the desired value does not activate the controller. Proportional action (Gradient K C [%]) 100 % Controller output Y 50 % K C = 500 % K C = 200 % K C = 100 % K C = 50 % X w Deviation MR*0.2 MR*0.4 MR*0.6 MR*0.8 MR Process variables: Cond, Conc, SAL 70

71 Controller Functions Pulse Length / Pulse Frequency Controller Pulse Length Controller ( PLC) The pulse length controller is used to operate a valve as an actuator. It switches the contact on for a time that depends on the controller output. The period is constant. A minimum ON time of 0.5 sec is maintained even if the controller output takes corresponding values. Output signal (relay contact) of pulse length controller ON time (Y = 20 %) ON time (Y = 80 %) Pulse length Pulse Frequency Controller ( PFC) The pulse frequency controller is used to operate a frequencycontrolled actuator (metering pump). It varies the frequency with which the contacts are switched on. The maximum pulse frequency [pulses/min] can be defined. It depends on the actuator. The contact ON time is constant. It is automatically calculated from the user-defined maximum pulse frequency: Output signal (relay contact) of pulse frequency controller ON time Pulse frequency (Y = 20%) Pulse frequency (Y = 80%) 71

72 Configuration Controller (For description, see Controller Functions) Process variable, controller type, setpoint 1 1 Press any arrow key. 2 Select CONF using keys, press. 3 Select parameter set using keys, 2 press. 4 Select REL1/REL2 menu using keys, press. 5 All items of this menu group are indicated by the CTR: code. Press to select menu, edit with arrow keys (see next page). Confirm (and proceed) with. 3 6 End: Press meas key until the [meas] mode indicator is displayed. 4 5 meas 6 Select process variable Controller type Pulse length Pulse frequency Setpoint Neutral zone Controller: P action Controller: I action Controller: D action Behavior during HOLD 5 72

73 Menu item Action Choices Select process Select desired process Cond/TMP variable variable using keys. Configuration Press to confirm. Controller type Pulse length Pulse length controller (PLC) or pulse frequency controller (PFC) Select using keys. Press to confirm. Only with PLC: Pulse length Adjust using keys. PLC / PFC SEC (0010 SEC) Pulse frequency Press to confirm. Only with PFC: Pulse frequency Adjust using keys P/M (0060 P/M) (pulses per minute) Setpoint Press to confirm. Adjust setpoint using keys. Press to confirm. Within meas. range If the adjusted range is exceeded, the device automatically switches to the next higher range (Autorange) 73

M420 Cond Ind. Instruction Manual.

M420 Cond Ind. Instruction Manual. M420 Cond Ind Instruction Manual www.mt.com/pro Warranty Warranty Defects occurring within 1 year from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender).

More information

Stratos Pro A2... MSPH

Stratos Pro A2... MSPH Stratos Pro A2... MSPH Instruction Manual Latest Product Information: www.knick.de Warranty Warranty Defects occurring within 3 years from delivery date shall be remedied free of charge at our plant (carriage

More information

Stratos Pro A4... PH Instruction Manual

Stratos Pro A4... PH Instruction Manual Stratos Pro A4... PH Instruction Manual Latest Product Information: www.knick.de Warranty Warranty Defects occurring within 3 years from delivery date shall be remedied free of charge at our plant (carriage

More information

The Art of Measuring. Stratos MS A405. User Manual English. Conductivity Measurement. Latest Product Information:

The Art of Measuring. Stratos MS A405. User Manual English. Conductivity Measurement. Latest Product Information: The Art of Measuring. User Manual English Stratos MS A405 Conductivity Measurement Latest Product Information: www.knick.de Table of Contents 3 About This Manual...5 Documents Supplied...6 Introduction...

More information

Stratos Pro A2.. CC Dual Conductivity Measurement

Stratos Pro A2.. CC Dual Conductivity Measurement The Art of Measuring. User Manual English Stratos Pro A2.. CC Dual Conductivity Measurement Latest Product Information: www.knick.de Return of Products, Disposal Return of products Please contact our Service

More information

Stratos Pro A2... PH. Instruction Manual. Latest Product Information:

Stratos Pro A2... PH. Instruction Manual.   Latest Product Information: Stratos Pro A2... PH Instruction Manual Latest Product Information: www.knick.de Warranty Warranty Defects occurring within 3 years from delivery date shall be remedied free of charge at our plant (carriage

More information

Stratos Pro A2... PH. Betriebsanleitung. Stratos Pro A2.. MSPH. ph Measurement. Produktinformation: User Manual.

Stratos Pro A2... PH. Betriebsanleitung. Stratos Pro A2.. MSPH. ph Measurement. Produktinformation:  User Manual. II 1G Ex ia IIC T3/T4/T6 14163 Berlin 14163 Berlin SE 706X/1-NMSN SE 706X/2-NMS 14163 Berlin BVS 10 ATEXXE0 BVS 10 ATEX E089 II 1G ia IIC T II 1GSE Ex 706X/1-NM ia IIC Ex T3/T4/T6 The Art of Measuring.

More information

The Art of Measuring. Stratos Evo A402. User Manual English. Conductivity Measurement. Latest Product Information:

The Art of Measuring. Stratos Evo A402. User Manual English. Conductivity Measurement. Latest Product Information: The Art of Measuring. User Manual English Stratos Evo A402 Conductivity Measurement Latest Product Information: www.knick.de Table of Contents 3 Basics...5 Documents Supplied...6 Introduction... 7 Overview

More information

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection Process Analysis Systems Chem Energy Pharm Food Water Stratos Pro A4 MSPH/MSPH Connection Connection of Memosens interface of 4-wire device with 2 Memosens sensors Model used: Stratos Pro A401N MSPH/MSPH

More information

Stratos Pro A2... OXY

Stratos Pro A2... OXY Stratos Pro A2... OXY Instruction Manual Latest Product Information: www.knick.de Warranty Warranty Defects occurring within 3 years from delivery date shall be remedied free of charge at our plant (carriage

More information

Stratos Pro A4 PH. Connection

Stratos Pro A4 PH. Connection For up-to-date information, please visit www.m4knick.com Stratos Pro A4 PH Connection Connection of PH module with any desired analog sensor or with ISM or ISFET sensors. Operation of Memosens sensors

More information

Process Analysis Systems. Stratos Pro A2 CONDI. Chem Energy Pharm Food Water. Connection

Process Analysis Systems. Stratos Pro A2 CONDI. Chem Energy Pharm Food Water. Connection Process Analysis Systems hem Energy Pharm Food Water Stratos Pro A2 ONDI onnection onnection of ONDI module with electrodeless sensors Model used: Stratos Pro A201N ONDI 1 ONDI module ontrol room Module

More information

Instruction Manual DULCOMETER 2201 X Cond

Instruction Manual DULCOMETER 2201 X Cond Instruction Manual DULCOMETER 2201 X Cond ProMinent Dosiertechnik GmbH D-69123 Heidelberg Germany ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5 11 D-69123 Heidelberg Postfach 10 17 60 D-69007 Heidelberg

More information

Connection of OXY module with oxygen sensor (SE 706, Mettler Toledo InPro 6800, Hamilton Oxyferm) Model used: Stratos Pro A401N OXY/ V AC/DC

Connection of OXY module with oxygen sensor (SE 706, Mettler Toledo InPro 6800, Hamilton Oxyferm) Model used: Stratos Pro A401N OXY/ V AC/DC Process Analysis Systems Chem Energy Pharm Food Water Stratos Pro A4 OXY Connection Connection of OXY module with oxygen sensor (SE 706, Mettler Toledo InPro 6800, Hamilton Oxyferm) Model used: Stratos

More information

Stratos Pro A2.. CONDI Conductivity Measurement with Toroidal Sensors

Stratos Pro A2.. CONDI Conductivity Measurement with Toroidal Sensors The Art of Measuring. User Manual English Stratos Pro A2.. CONDI Conductivity Measurement with Toroidal Sensors Latest Product Information: www.knick.de About This Manual Return of products Please contact

More information

Transmitter Your Consultant: 02/

Transmitter Your Consultant: 02/ Transmitter 7500 Your Consultant: 02/99 52 120 435 Mettler-Toledo GmbH, Process, Postfach, 8902 Urdorf, Switzerland Phone +41 (01) 736 22 11, Fax +41 (01) 736 26 36 Transmitter 7500 Warranty Defects occurring

More information

Instruction manual. O 2 Transmitter 4100 e/2(x)h

Instruction manual. O 2 Transmitter 4100 e/2(x)h Instruction manual O 2 Transmitter 4100 e/2(x)h Warranty Defects occurring within 1 year from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender). Subject

More information

Instruction Manual DULCOMETER 2201 X ph

Instruction Manual DULCOMETER 2201 X ph Instruction Manual DULCOMETER 2201 X ph ProMinent Dosiertechnik GmbH D-69123 Heidelberg Germany ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5 11 D-69123 Heidelberg Postfach 10 17 60 D-69007 Heidelberg

More information

Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells

Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells Features M LED-Display 14.2 mm red M Indicating range 2000(0) Digit M Measuring ranges programmable from 0... 2.000

More information

Stratos Eco 2405 ph. User Manual. Latest Product Information:

Stratos Eco 2405 ph. User Manual. Latest Product Information: Stratos Eco 2405 ph User Manual Latest Product Information: www.knick.de 093783 Subject to change without notice. Return of Products Under Warranty Please contact our Service Team before returning a defective

More information

Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual

Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430 Operation Manual INDEX 1 Specifications 2 Assembly and installation 2.1 Precautions for installation 2.2 Installation of controller

More information

Instruction manual. ph Transmitter 2100 e/2(x)h

Instruction manual. ph Transmitter 2100 e/2(x)h Instruction manual ph Transmitter 2100 e/2(x)h 70090 Warranty Defects occurring within 1 year from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender). Subject

More information

Please enter the identity code of your device here!

Please enter the identity code of your device here! Operating Instructions DULCOMETER D2C Part 2: Adjustment and Operation, Measured Variables ph/ ProMinent D2C2-001-pH/-GB ph/cl 2 7.00 ph 0.45 ppm DULCOMETER STOP START ph/cl 2 7.00 ph 0.45 ppm DULCOMETER

More information

The Art of Measuring. User Manual English. Portavo 904(X) COND. Latest Product Information:

The Art of Measuring. User Manual English. Portavo 904(X) COND. Latest Product Information: The Art of Measuring. User Manual English Portavo 904(X) COND Latest Product Information: www.knick.de Basics 3 Return of products under warranty Please contact our Service Team before returning a defective

More information

Measuring Module M 700 Cond Ind 7700(X)

Measuring Module M 700 Cond Ind 7700(X) Measuring Module M 700 Cond Ind 7700(X) For Conductivity Measurement with Electrodeless Sensors 52121224 Warranty Defects occurring within 1 year from delivery date shall be remedied free of charge at

More information

Stratos Pro A2... PH. Betriebsanleitung. Produktinformation: English. Betriebsanleitung deutsch. Ex 706X/1-NM SE 706X/2-NM

Stratos Pro A2... PH. Betriebsanleitung. Produktinformation:  English. Betriebsanleitung deutsch. Ex 706X/1-NM SE 706X/2-NM II 1G Ex ia IIC T3/T4/T6 14163 Berlin 14163 Berlin SE 706X/1-NMSN SE 706X/2-NMS 14163 Berlin BVS 10 ATEXXE0 BVS 10 ATEX E089 II 1G ia IIC T II 1GSE Ex 706X/1-NM ia IIC Ex T3/T4/T6 The Art of Measuring.

More information

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator Hazardous-Area 830 X R Loop-Powered 16 830 X S1 Loop-Powered 16 830 X S2 Loop-Powered 16 15 Loop-Powered Digital 830 X Loop-Powered 830 X R 830 X S1 830 X S2 The 830 X loop-powered digital indicators are

More information

Portavo 904 X Multi. Multiparameter Ex

Portavo 904 X Multi. Multiparameter Ex Multiparameter Ex Portavo 904 X Multi The world's only portable device for liquid analysis with ATEX approval for measurements up to zone 0/1. Ideal for applications in the process industry. For the first

More information

+GF+ SIGNET Conductivity/Resistivity Transmitter Instructions

+GF+ SIGNET Conductivity/Resistivity Transmitter Instructions GF SIGNET 8850 Conductivity/Resistivity Transmitter Instructions ENGLISH 8850.090 A9/99 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to

More information

Stratos PROFIBUS 2221 X Cond. Instruction Manual

Stratos PROFIBUS 2221 X Cond. Instruction Manual Stratos PROFIBUS 2221 X Cond Instruction Manual Warranty Defects occurring within 3 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender). Accessories:

More information

ph 2700i(X) module Instruction manual Order number:

ph 2700i(X) module Instruction manual Order number: ph 2700i(X) module Instruction manual Order number: 52 121 276 Warranty Defects occurring within 1 year from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by

More information

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL This manual contains important safety information about installation and use of this equipment. Ignoring this information could result in injuries or damages. It is strictly forbidden to use this equipment

More information

OPT2011. High-performance distance sensor. Operating Instructions

OPT2011. High-performance distance sensor. Operating Instructions OPT2011 High-performance distance sensor Operating Instructions Status: 15/07/2013 2 Table of Contents 1. Use for Intended Purpose 4 2. Safety Precautions 4 2.1. Safety Precautions 4 2.2. Laser/LED warning

More information

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

English. Operating Manual. Conductive point level switch MLR120.  Retain for later reference. Companies / brands of GHM English Operating Manual Conductive point level switch MLR120 Companies / brands of GHM www.ghm-group.de Retain for later reference Table of contents Page 1. Proper use (application areas)... 3 Safety

More information

O i(X) module. Instruction manual. Order number:

O i(X) module. Instruction manual. Order number: O 2 4700i(X) module Instruction manual Order number: 52 121 275 Warranty Defects occurring within 1 year from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

Please enter the identity code of your device here!

Please enter the identity code of your device here! Operating Instructions DULCOMETER D2C Part 2: Adjustment and Operation, Measured Variables ph/orp ProMinent D2C2-001-pH/ORP-GB ph/orp 7.20 ph 750 mv DULCOMETER STOP START ph/orp 7.20 ph 750 mv DULCOMETER

More information

User Manual. Portamess 913 Cond and Portamess 913 X Cond

User Manual. Portamess 913 Cond and Portamess 913 X Cond User Manual Portamess 913 Cond and Portamess 913 X Cond Warranty Defects occurring within 3 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender).

More information

703 Laboratory Conductivity Meter

703 Laboratory Conductivity Meter 703 Laboratory Conductivity Meter Sensoface Sensoface monitors the sensor and measuring equipment and provides information on sensor selection and handling. It reports clock memory loss and requests regular

More information

Standard-Signal Isolation Amplifiers. VariTrans A 21000

Standard-Signal Isolation Amplifiers. VariTrans A 21000 Standard-Signal Isolation Amplifiers The first standard-signal isolation amplifier with protective separation and broad-range power supply in the 6-mm class. The Task Isolation and conversion of 0... 20

More information

Analog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)

Analog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action) Page 1/10 JUMO AQUIS 500 ph Transmitter/Controller for ph, ORP, NH 3 (ammonia) concentration and temperature Brief description The instrument is used for measuring/controlling the ph, ORP or NH 3 (ammonia)

More information

+GF+ SIGNET ph/orp Transmitter Instructions

+GF+ SIGNET ph/orp Transmitter Instructions GF SIGNET 8750 ph/orp Transmitter Instructions ENGLISH 8750.090 A9/99 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

More information

Protos 3400(X) Process Analysis System

Protos 3400(X) Process Analysis System The Art of Measuring. Protos 3400(X) Process Analysis System User Manual English Measuring Module Protos COND 3400(X)-041 For Conductivity Measurement with 2- or 4-Electrode Sensors Latest Product Information:

More information

Bargraph for quick range overview The digital indicators provide a bargraph in addition to the digital display. This gives you all information

Bargraph for quick range overview The digital indicators provide a bargraph in addition to the digital display. This gives you all information Loop-Powered Digital Indicators 830 Loop-Powered Process Indicator The 830 loop-powered digital indicators are universally applicable. The range (either 0 to 20 ma or 4 to 20 ma) is simply selected via

More information

Versatile Transmitter Series For Intelligent Measurement Solutions. INGOLD Leading Process Analytics

Versatile Transmitter Series For Intelligent Measurement Solutions. INGOLD Leading Process Analytics INGOLD Leading Process Analytics Transmitter Series M400 / M420 / M300 Transmitters Extended ISM functions Easy handling Intuitive user interface Multi-parameter Versatile Transmitter Series For Intelligent

More information

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,

More information

Extremely robust process analyzers with unique color-coded user interface, for all common analog and digital sensors

Extremely robust process analyzers with unique color-coded user interface, for all common analog and digital sensors Process Analysis Systems Chem Energy Pharm Food Water Stratos Pro Extremely robust process analyzers with unique color-coded user interface, for all common analog and digital sensors Process analytics

More information

Intrinsically safe batch controller Batching Master 110i

Intrinsically safe batch controller Batching Master 110i Intrinsically safe batch controller Batching Master 110i Installation Guide BVS 04 AT E 172 Revision 12.2 IBS BatchControl GmbH Im Sträßchen 2-4 Tel.: ++49 2441 9199 801 53925 Kall Fax.: ++49 2441 9199

More information

CX3100 Intelligent Conductivity Transmitter

CX3100 Intelligent Conductivity Transmitter CX3100 Intelligent Conductivity Transmitter Operation Manual CX3100 CONTENTS Precautions for Installation Brief Instruction 1 1. Specifications 4 2. Assembly and Installation 2.1 Transmitter Installation

More information

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291 TI01198C/07/EN/02.15 71288268 Products Solutions Services Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291 Portable multiparameter device for Memosens ph, conductivity and oxygen

More information

Analog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)

Analog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action) Data Sheet 202560 Page 1/12 JUMO AQUIS 500 ph Transmitter/Controller for ph, ORP, NH 3 (ammonia) concentration and temperature Brief description The device is used for measuring/controlling the ph, ORP

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

NN1 PH1 CC1 DM1 DB1. TABLE V - Options. Mounting Hardware. Instruction Books NN2 PH2 CC2 DM2 DB2. Certificates. PID Control NN C3.

NN1 PH1 CC1 DM1 DB1. TABLE V - Options. Mounting Hardware. Instruction Books NN2 PH2 CC2 DM2 DB2. Certificates. PID Control NN C3. 0---0 January 00 Quick Start Guide for UDA Universal Dual Analyzer For detailed instructions see UDA Universal Dual Analyzer Product Manual 0---. Step. Model Number Interpretation Write your analyzer model

More information

The Model 703 offers a wide range of practical features to meet the numerous requirements of everyday measuring tasks.

The Model 703 offers a wide range of practical features to meet the numerous requirements of everyday measuring tasks. Laboratory Meters The requirements for lab measurements become stricter every day. Quality assurance and measurement documentation in accordance with GLP are a must in many areas. 703 Laboratory Conductivity

More information

Modular analysis transmitter for ph/orp, conductivity measurement

Modular analysis transmitter for ph/orp, conductivity measurement Modular analysis transmitter for ph/orp, conductivity measurement Type 8285 can be combined with... High flexibility provided by modular concept for several measuring parameters Outstanding features for

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

OFP401P0189. Color Sensor. Operating Instructions

OFP401P0189. Color Sensor. Operating Instructions OFP401P0189 Color Sensor Operating Instructions Last update: 23 May 2013 2 Table of contents 1. Proper Use 4 2. Safety Precautions 4 3. EC Declaration of Conformity 4 4. Technical Data 5 4.1. Connection

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications. Modular Housings for Hazardous Areas For transmission of 0(4)... 20-mA signals from hazardous areas or supply of intrinsically safe 2-wire transmitters. The Task The power supply/isolator is used to supply

More information

Transmitter Cond 7100 e /2 (X)H

Transmitter Cond 7100 e /2 (X)H Transmitter Cond 7100 e/2(x)h Command Specification Page: 1 of 16 Transmitter Cond 7100 e /2(X)H Transmitter Specific Command Specification using the HART Communications Protocol Revision 1.1 Initial Release:

More information

Scanner 2000 Steam Mass Flow Transmitter

Scanner 2000 Steam Mass Flow Transmitter 3352051/2 IM-P335-24 MI Issue 2 Scanner 2000 Steam Mass Flow Transmitter Installation and Maintenance Instructions 1. Safety information 2. Mechanical installation 3. Configuring software 4. Wiring procedures

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

CombiLyz AFI4 / AFI5 Inductive conductivity transmitter

CombiLyz AFI4 / AFI5 Inductive conductivity transmitter Main features Range from 500 µs/cm to 1000 ms/cm ll hygienic design Built in graphical display CombiView DFON Very fast temperature compensation Easy and full programmable with FlexProgrammer 9701 FI5

More information

FLOW MONITOR & TRANSMITTER

FLOW MONITOR & TRANSMITTER FLS M9.02 FLOW MONITOR & TRANSMITTER SAFETY INSTRUCTIONS General Statements Do not install and service the product without following the Instruction Manual. This item is designed to be connected to other

More information

LDCL DIGITAL CONTROLLER OPERATING MANUAL

LDCL DIGITAL CONTROLLER OPERATING MANUAL This manual contains important safety informations about installation and use of this equipment. Ignoring this informations could result in injuries or damages. It is strictly forbidden to use this equipment

More information

Communication Module M 700 EC 700(X)

Communication Module M 700 EC 700(X) Communication Module M 700 EC 700(X) For Actuating Probe Controllers (EC 400) - Automatic ph Measurement - Warranty Defects occurring within 1 year from delivery date shall be remedied free of charge at

More information

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction User's Guide 1/16 th DIN ph Controller Model 48PH2 Introduction Thank you for selecting the Extech Model 48PH2 controller. This 1/16 th DIN-size controller offers dual display, high resolution measurements,

More information

Signal Doublers. VariTrans A 20300

Signal Doublers. VariTrans A 20300 ProLine Interface Technology Signal Doublers Signal doublers with two switchable calibrated outputs in a 6 mm housing, also for applications with high output loads. The Task Isolation and transmission

More information

Conductivity Measuring System

Conductivity Measuring System Brief Operating Instructions Smartec S CLD134 Conductivity Measuring System These instructions are Brief Operating Instructions. For detailed information, please read the Operating Instructions. The complete

More information

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply. Universal Isolation Amplifiers The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply. The Housing At a width of just 12.5 mm, the modular housing with pluggable

More information

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing. Standard-Signal Isolation Amplifiers The world s first 3-port standard signal isolator in a 6-mm modular housing. The Task Isolation and, if required, conversion of 0... 20 ma, 4... 20 ma, and 0... 10

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

SensoTrans DMS P 32200

SensoTrans DMS P 32200 ProLine Interface Technology Strain Gauge Transmitters The transmitters for strain gauge full bridges in a 6 mm housing with infrared interface and SIL approval. The Task In many different industrial applications

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

VariTrans P The Problem The variety of tasks results in a large number of different devices.

VariTrans P The Problem The variety of tasks results in a large number of different devices. Universal Isolation Amplifiers The Multimeter among the isolation amplifiers. With 480 switchable calibrated ranges and broad-range power supply. The broad-range power supply for all common supply voltages

More information

JUMO dtrans AS 02. Transmitter/controller for standard signals and temperature

JUMO dtrans AS 02. Transmitter/controller for standard signals and temperature sales@jumo.co.uk info.us@jumo.net Page 1/1 JUMO dtrans AS 0 Transmitter/controller for standard signals and temperature Brief description The JUMO dtrans AS 0 is a compact, modular instrument. It is highly

More information

Protos 3400(X) Process Analysis System

Protos 3400(X) Process Analysis System The Art of Measuring. Protos 3400(X) Process Analysis System User Manual English Measuring Module Protos PH 3400(X)-033 For Simultaneous Measurement of ph Value and Temperature with Pfauder Differential

More information

Microprocessor ph/orp Controller

Microprocessor ph/orp Controller PC3030A/PC-3050 Microprocessor ph/orp Controller Operating Manual CONTENTS 1 Specifications... 2 Assembly and installation... 2.1 Precautions for installation.. 2.2 Install the controller on the wall mount

More information

+GF+ SIGNET 5800CR Conductivity/Resistivity Monitor Instructions

+GF+ SIGNET 5800CR Conductivity/Resistivity Monitor Instructions GF SIGNET 5800CR Conductivity/Resistivity Monitor Instructions ENGLISH 35800CR.0901 D1/98 CAUTION! Refer to instruction manual for more details. Remove power to unit before wiring input and output connections.

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O s 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

Temperature Switches

Temperature Switches ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,

More information

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10 4070.83/4--10 PumpDrive DPM Installation and Operating Instructions Dual Pump Module (DPM) These installation and operating instructions are not valid on their own. They must always be applied in conjunction

More information

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz GRUNDFOS ALLDOS DATA BOOKLET Measuring amplifiers and controllers for conductivity measurement 50/60 Hz TM042232 if Contents Product features Conex DIS 3 3 Identification Type key,, controller 4 Type key,,

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

Intelligent SUNTEX EC4110(RS) Conductivity Transmitter

Intelligent SUNTEX EC4110(RS) Conductivity Transmitter Cond.. Res. C Intelligent SUNTEX EC4110(RS) Conductivity Transmitter Principle Conductivity, which is highly dependent on the amount of dissolved salts, is a measurement of the level of ion concentration

More information

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR LC1 MANUAL 062114 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features Dimensions WIRING

More information

InBin-P Pressure switches from 5 Pa Pa

InBin-P Pressure switches from 5 Pa Pa InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact

More information

JUMO AQUIS 500 AS. Indicator/Controller for Standard Signals Type B Operating Instructions /

JUMO AQUIS 500 AS. Indicator/Controller for Standard Signals Type B Operating Instructions / JUMO AQUIS 500 AS Indicat/Controller f Standard Signals Type 202568 B 20.2568.0 Operating Instructions 2010-06-09/00528531 WARNING: A sudden malfunction of the instrument, one of the senss connected to

More information

JUMO Quantum PID100/PID200/PID300

JUMO Quantum PID100/PID200/PID300 Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and

More information

The Art of Measuring. Multiparameter analyzers with Fieldbus technology. For analog, digital and Memosens sensors. Stratos

The Art of Measuring. Multiparameter analyzers with Fieldbus technology. For analog, digital and Memosens sensors. Stratos The Art of Measuring. Multiparameter analyzers with Fieldbus technology. For analog, digital and Memosens sensors Multi-Talents with Bus Communication With their exceptional functionality, reliability

More information

Mettler-Toledo Smart Communications Protocol Revison 1.0: June 9, 2004 Cond Ind 7100/2(X)H Command Specification Page: 1 of 16

Mettler-Toledo Smart Communications Protocol Revison 1.0: June 9, 2004 Cond Ind 7100/2(X)H Command Specification Page: 1 of 16 Cond Ind 7100/2(X)H Command Specification Page: 1 of 16 Cond Ind 7100/2(X)H Transmitter Specific Command Specification using the HART Communications Protocol Revision 1.1 Initial Release: February 13,

More information

Signet 5900 Salinity Monitor

Signet 5900 Salinity Monitor Signet 5900 Salinity Monitor *35900.0901* 35900.0901 Rev. E 3/06 English Contents 1. Power Connections 2. Compatible Sensor Wiring 3. 4 20 ma Current Output Connections 4. Relay Connections 5. Relay Operation

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Quick Start Guide MC-III TM Flow Analyzer

Quick Start Guide MC-III TM Flow Analyzer Quick Start Guide MC-III TM Flow Analyzer A Quick Reference on Mounting, Wiring, & Configuring the MC-III EXP or WP Flow Analyzer For complete instructions, see MC-III EXP User Manual, Part No. 9A-50165003

More information

Modular analysis transmitter for ph/orp, conductivity measurement

Modular analysis transmitter for ph/orp, conductivity measurement Modular analysis transmitter for ph/orp, conductivity measurement Type 8285 can be combined with... High flexibility provided by modular concept for several measuring parameters Outstanding features for

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

CombiLyz AFI4 / AFI5 Inductive conductivity transmitter

CombiLyz AFI4 / AFI5 Inductive conductivity transmitter Main features Range from 500 µs/cm to 1000 S/cm ll hygienic design Built in graphical display CombiView DFON Very fast temperature compensation Easy and full programmable with FlexProgrammer 9701 FI5 split

More information