Operation and Installation Manual

Size: px
Start display at page:

Download "Operation and Installation Manual"

Transcription

1 Operation and Installation Manual SmartLINK M 13 x

2 Content 1 Document Content Function Target group: Authorised personnel Symbols and abbreviations used Proper use General notes on safety Warning of misuse Disclaimer Product Description Type code Terms and conditions and use Technical data Assembly General notes on assembly General notes on electrical connection Commissioning and Maintenance Commissioning and function test Maintenance Disassembly and Disposal Disassembly Disposal Scope of Supply Attachment Declaration of Conformity Declaration of ECconformity...15

3 1 Document Content 1.1 Function This operating instructions manual provides necessary information on installation, commissioning, safe operation, disassembly and disposal. 1.2 Target group: Authorised personnel All operations described in this operating instructions manual may only be performed by trained professional staff authorised by the operator. Only install and commission the SmartLINK if you have read and understood the operating instructions manual and are familiar with the applicable regulations. 1.3 Symbols and abbreviations used 1.4 Proper Use The products described here have been developed in order to ensure functions as part of an overall system. It is the responsibility of the installer to ensure the correct overall functioning. It may be used only in accordance with the following versions or for applications approved by the installer. Detailed information on the application range can be found in the chapter Product description. 1.5 General notes on safety The safety notes of the operating instructions manual and the countryspecific installation, safety and accident prevention regulations are to be followed. Residual risks are not known when observing the notes on safety and the instructions relating to the installation, commissioning, operation and maintenance. 1 i! Information, tip, note: This symbol highlights helpful additional information Caution: Failure to comply with this warning can lead to disorders & malfunctions. 1.6 Warning of misuse In case of inappropriate or improper use or tampering, malfunctions as well as risks, e.g. due to missing signal transmission, can arise for people due to the use of the SmartLINK cable transfer. Please follow the applicable standards / guidelines (DIN EN, VdS) in this respect. 2! Warning: Failure to comply with this warning can damage the SmartLINK. Power supply Supply channel Extension/additional modules Input Output White Yellow Brown Red Blue Green Switchon time PWR CHL EXT IN OUT WH YE BN RD BL GN ED 1.7 Disclaimer For damages or malfunctions caused by incorrect installation or failure to comply with this instruction manual, no liability is assumed. For damages resulting from the use of spare parts or accessories not approved by the manufacturer, any further liability of the manufacturer is excluded. Any unauthorised repairs, modifications and additions are not permitted for reasons of safety and exclude any liability of the manufacturer for damages resulting from this.

4 2 Product Description 2.1 Type code This operating instructions manual is valid for the following types: M Guard/ lock plate for tube frame* M Guard/ lock plate for wood* M Lock plate / mounting box for tube frame* M Lock plate / mounting box for wood* * hereinafter referred to in the operating instructions manual as SmartLINK Figure 2.3 Current [A] Current / Time CHL 2.2 Terms and conditions and use The SmartLINK is intended for installation in all standard timber, PVC and aluminium profile doors. It is used to secure the transmission of signals and voltages of the connected components. The SmartLINK enables domestic and commercial doors to be simply Duration [s] 3 and economically connected to power sources and signal sources, such as fingerprint, engine locks, etc. Due to the ease of installation and its construction, the domestic and commercial doors can be completely manufactured in the workshop, tested as an assembly and 4 accepted in the object immediately after installation. 2.3 Technical data Dimensions 8,5 20 Power supply 1 (PWR): V DC, 3 A DC, 2 pole screw plugin terminal, black, RM 3.5 mm, max. core crosssection: 1.0 mm² Power supply 2 (CHL): 0 48 V DC, 5 A DC (2 sec. ED, see Fig. 2.3), 2 pole screw plugin terminal, black, RM 3.5 mm, max. core crosssection: 1.0 mm² Inputs (IN 1 IN 4): galvanically isolated, max. 48 V DC / 5 ma DC, 2 pole screw plugin terminal, black, RM 3.5 mm, max. core crosssection: 1.0 mm² Outputs (OUT 1 OUT 4): galvanically isolated, max. 48 V DC / 500 ma DC, 8 pole screw plugin terminal, black, RM 3.5 mm, max. core crosssection: 1.0 mm² Operating temperature range: 20 C to 70 C Line connection (KÜ): LiF9Y11Y 6 x 0.34 mm², halogenfree Housing: Plastic (ABS), protection type IP 42 Weight: 600 g ,5 300

5 3 Assembly M Flügel Leaf Rahmen Frame 3.1 General notes on assembly Due to the plurality of profiles and fittings available on the market, no general information for mounting can be given since these systems differ in several dimensions. Please check the place of installation and the space available in the rabbet and profile area before the beginning of assembly. R4 R4 Place of assembly: Door rabbet Minimum installation depth M / 86 : 28 mm Minimum installation depth M / 26 : 50 mm The place of installation should be chosen in such a way that the coil is not crushed when the door is closed The SmartLINK must be installed in a Ushape (see Fig.) In addition to the generally valid state of the art, the following technical codes are to be particularly observed: DIN VDE 0100, VdS M / M max. 90mm M Installation in tubular frame doors Processing of frame / leaf Mill long slot width 20 mm and length mm, corner radius max. 4 mm (28 mm deep) Predrill for forend screw 2x Cables are run through the profile max. 90mm max. 180

6 M A 20 Flügel Leaf Frame Rahmen B M / M max. 80mm A B 8 max. 180 max. 80mm 7 8 M Installation in wooden doors Processing of frame / leaf Mill recess for lock plates radius 10 mm (3 mm deep) Mill recess of mm width and mm length (28 mm deep) Drill holes for cable exit Ø16 mm M Flügel Leaf R4 Rahmen Frame R4

7 M Installation in tubular frame doors Processing of frame / leaf Mill long slot width 20 mm and length mm, corner radius max. 4 mm (28 mm deep for lock plate, 50 mm deep for builtin box) Predrill for forend screw 2x Cables are run through the profile M Installation in wooden doors Processing Frame: Mill recess for lock plates radius 10 mm (3 mm deep) Mill recess of mm width and mm length (28 mm deep) Drill holes for cable exit Ø16 mm Leaf: Mill recess for mounting box of 20 mm width and mm length, radius max. 6 mm (50 mm deep) Drill holes for cable exit Ø16 mm 9 M Flügel Leaf A 20 R6 Frame Rahmen B General notes on electrical connection The electrical connection may only be done in deenergised state and by authorised personnel For connection examples, see attachment A B

8 4 Commissioning and Maintenance 5 Disassembly and Disposal 4.1 Commissioning and function test The SmartLINK is activated by turning on the supply voltage (PWR). The master begins a scanning process for connected slave stations (master: Status LED flashes green). Upon successful completion (master and slave 1: Status LED is green), the SmartLINK is ready for operation. If an error is detected in the scanning process (Master: Status LED flashes red) or the communication is faulty (Master: Status LED lights up red), all connections are to be checked and the scanning is to be repeated upon restarting. 5.1 Disassembly The SmartLINK is to be dismantled only in deenergised state. The dismantling of the screw plugin terminals must be done in accordance with Fig. 5.1 with a screwdriver.! Should a permanent disruption of communication occur during operation (master: Status LED is red), all outputs are turned off and the SmartLINK is to be restarted. Shortterm faults in the communication (master or slave 1: status LED flashes red) lead to a shutoff of all outputs for the duration of the fault. If there is no further disruption of communication (master and slave 1: status LED is green) the operation automatically resumes. Fig Maintenance When properly installed and used properly, the electronics do not require servicing. 5.2 Disposal The SmartLINK is to be disposed of professionally in accordance with the national regulations and laws. 12 We recommend a regular visual and functional test is undertaken with the following steps: Check SmartLINK for tightness Check lead, spring and housing for damage 6 Scope of Delivery It is recommended to clean exposed parts at least once per year with a soft, dry cloth. Never use oil or siliconecontaining lubricant or cleaning agent. Damaged or defective equipment are to be replaced. 1 pc. Cable transition SmartLINK M 13 x 1 pc. Installation manual SmartLINK M 13 x 1 accessories kit for electronics in the PEbag 2 pcs. Screw plugin terminal RM 3.50 pluggable, 8pole, no pcs. Screw plugin terminal RM 3.50 pluggable, 8pole no pcs. Screw plugin terminal RM 3.50 pluggable, 2pole 2 pcs. Cable ties 2.5 x 100 mm 1 accessories kit for attachment in the PEbag 4 pcs. Tapping screw countersunk, Pozi DIN 7982 PZ C 3.5 x 50, A2 4 pcs. Tapping screw countersunk, Pozi DIN 7982 PZ C 3.5 x 25, A2 4 pcs. Countersunk screw, Pozi DIN 965 PZ M4 x 8, A2, 70461M

9 7 Attachment Connection example: Input switching (valid for the inputs IN18) Connection example: Schematic diagramm Master: PWR IN 12V 24V Signal transmitter Input switching 1: Loop through the voltage PWR Voltage Voltage Slave 1: CHL IN 12V 48V Signal transmitter Input switching 2: Loop through the voltage CHL Control signals Control signals Control signals Control signals IN Optional 12V 48V Extern Input switching 3: Applying an external voltage Note: The correct polarity of the inputs must be ensured! The input switching can be freely selected for each input (IN 18) Connection example: Power supply Connection example: Output switching (valid for outputs OUT18) Master: PWR CHL V 24V 12V 48V Master: PWR OUT 12V 24V Load Output switching 1: Loop through the voltage PWR Slave 1: PWR CHL 1 2 Optional Load Load Slave 1: CHL OUT Optional 12V 48V Load Output switching 2: Loop through the voltage CHL Optional Note: The correct polarity of the voltage PWR is to be ensured! The CHL connection is optional and can be freely assigned. OUT 12V 48V Extern Output switching 3: Loop through an external voltage Note: The correct polarity of the outputs is to be ensured! The output switching can be freely selected for each output (IN 18).

10 8 Declaration of Conformity 8.1. EC Declaration of Conformity 15 16

11 Specifications subject to change without notice. MA Stand: 4416 LINK GmbH D Butzbach Telephon: 49 (0) Fax: 49 (0) info@linkgmbh.com Internet:

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Operating instructions Optical distance sensor. O5D15x / / 2014

Operating instructions Optical distance sensor. O5D15x / / 2014 Operating instructions Optical distance sensor O5D15x 706307 / 01 08 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

HST -TZ1 Guard-locking mechanism (Translation of Original Manual) Installation and Operating Manual for Components HST -TZ1 Guard-locking mechanism (Translation of Original Manual) HST-TZ1 Ident.-No.: 10234 HST-TZ1 Ident.-No.: 10236 HST-TZ1 Ident.-No.: 10235 HST-TZ1

More information

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content 7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018 Operating manual Diagnostic adapter VAS 611 009 CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 1 of 11 Imprint Title: Operating manual of diagnostic adapter VAS 611 009 Manufacturer: CAR-connect

More information

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH Instruction Manual LJU Automatisierungstechnik GmbH TF Infrared Manual Remote Control LJU Automatisierungstechnik GmbH Am Schlahn 1 14476 Potsdam Germany Tel.: +49 (0) 33201 / 414-0 Fax: +49 (0) 33201

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Assembly and Operating Instructions. NFC module for BDC-i440 control units

Assembly and Operating Instructions. NFC module for BDC-i440 control units NFC module en Assembly and Operating Instructions NFC module for BDC-i440 control units Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be

More information

Roto E-Tec. Electronic drive and control systems for windows and doors. Installation instructions for detachable miniature cable junctions

Roto E-Tec. Electronic drive and control systems for windows and doors. Installation instructions for detachable miniature cable junctions Roto E-Tec Electronic drive and control systems for windows and doors Installation instructions for detachable miniature cable junctions Liability exclusion All specifications in this brochure were diligently

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

P5/20M - P13/9M R7/17M - L120/11M

P5/20M - P13/9M R7/17M - L120/11M P5/20M - P13/9M R7/17M - L120/11M en Assembly and Operating Instructions Roller Shutter and Awning Drives with mechanic limit switching Important information for: Fitters Electricians Users Please forward

More information

Installation instructions Inclination sensor EC2019 EC / / 2013

Installation instructions Inclination sensor EC2019 EC / / 2013 Installation instructions Inclination sensor UK EC219 EC245 739215 / 3 1 / 213 Inhalt 1 Safety instructions 3 2 Mounting 4 3 Electrical connection 4 4 Dimensions 4 5 Technical Data 5 6 Characteristics

More information

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29 Linienkoppler S KNX Line coupler S KNX Line coupler S KNX 9070880 Status: March 16 (Subject to change) Page 1 of 29 KNX Contents Contents Page 1 General... 3 1.1 Using the product manual... 3 1.1.1 Structure

More information

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

Assembly and Operating Instructions. M2 module for BDC-i440 control units

Assembly and Operating Instructions. M2 module for BDC-i440 control units BDC-i440 M2 en Assembly and Operating Instructions M2 module for BDC-i440 control units Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be

More information

Operating instructions Optical distance sensor. OID25x / / 2014

Operating instructions Optical distance sensor. OID25x / / 2014 Operating instructions Optical distance sensor OID5x 70608 / 01 08 / 01 Contents 1 Preliminary note... 1.1 Symbols used... Safety instructions... Functions and features....1 Applications... Installation...5.1

More information

B63/ NS MS. EtherNet/IP LINK

B63/ NS MS. EtherNet/IP LINK 3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............

More information

HST -TS1 Guard-locking mechanism (Translation of Original Manual)

HST -TS1 Guard-locking mechanism (Translation of Original Manual) Installation and Operating Manual for Components HST -TS1 Guard-locking mechanism (Translation of Original Manual) HST-TS1 Ident.-No.: 10250 HST-TS1 Ident.-No.: 10252 HST-TS1 Ident.-No.: 10251 HST-TS1

More information

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions Optical distance sensor. OID25x / / 2015 Operating instructions Optical distance sensor OID25x 80228366 / 00 03 / 2015 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content 6 Disassembly and disposal 6.1 Disassembly....4 6.2 Disposal...4 Operating instructions.............pages 1 to 6 Original 7 Appendix 7.1 EU Declaration of conformity...5 7.2 Mounting and inspection protocol...6

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Operating Instructions

Operating Instructions Key Adapter CKS-K-AS2A-U-C20-PC (Unicode) EN Contents 1. About this document... 3 1.1. Scope...3 1.2. Target group...3 1.3. Key to symbols...3 1.4. Supplementary documents...3 2. Correct use... 4 3. Description

More information

HST -S1 Switching element (Translation of Original Manual)

HST -S1 Switching element (Translation of Original Manual) Installation and Operating Manual for Components HST -S1 Switching element (Translation of Original Manual) HST-S1 Ident.-No.: 10222 HST-S1 Ident.-No.: 10228 HST-S1 Ident.-No.: 10223 HST-S1 Ident.-No.:

More information

Flow Sensor SONOFLOW CO.55

Flow Sensor SONOFLOW CO.55 Flow Sensor SONOFLOW CO.55 Operating Manual Device: Model: Type: Flow Sensor SONOFLOW CO.55 Manufacturer: SONOTEC Ultraschallsensorik Halle GmbH Nauendorfer Str. 2 06112 Halle (Saale), Germany Phone: +49

More information

Dialock DT Lite. Operating instructions...2. Operating instructions

Dialock DT Lite. Operating instructions...2. Operating instructions Operating instructions Dialock DT Lite Operating instructions... Operating instructions. Notes on these operating instructions. Contents and target group of the instructions It is essential to pay attention

More information

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm 2 2.1 Air Quality Sensor LGS/A 1.1 The ABB i-bus KNX Air Quality Sensor 1.1 is a combined sensor for CO 2, temperature and humidity measurement (relative humidity). Three independent thresholds can be

More information

Operating Manual FPGA-based High-Speed Micro-PLC

Operating Manual FPGA-based High-Speed Micro-PLC ZX20T Operating Manual FPGA-based High-Speed Micro-PLC Zander GmbH & Co. KG Am Gut Wolf 15 52070 Aachen, Deutschland info@zander-aachen.de www.zander-aachen.de Part No.: E61-335-10 Edition: H03 This document

More information

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content Operating instructions.............pages 1 to 8 Original 6 Diagnostic 6.1 LED indications...5 6.2 Error....5 6.3 Locking of the solenoid interlock blocked...5 6.4 Diagnostic information...5 6.5 Diagnostic

More information

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Example / Beispiel / Exemple Type 6106 Operating Instructions Bedienungsanleitung Manuel d utilisation

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... 6 Disassembly and disposal 6.1 Disassembly....6 6.2 Disposal...6 7 EU Declaration of conformity Operating instructions.............pages 1 to 8 Original x.000 / 09.2017 / v.a. - 101178533- / I / 2017-08-31

More information

Operating manual. Series 450. Compact thermometer. BA01235O/09/en/

Operating manual. Series 450. Compact thermometer. BA01235O/09/en/ Operating manual Series 450 Compact thermometer BA01235O/09/en/01.13 71220279 2 Table of contents 1 Safety instructions... 3 2 Installation... 4 3 Wiring overview... 7 4 Commissioning... 7 5 Operation...

More information

Display Panel BAT 100 LSN. en Operation Guide

Display Panel BAT 100 LSN. en Operation Guide Display Panel BAT 100 LSN en Operation Guide Display Panel Table of Contents en 3 Table of contents 1 Safety 4 2 Short information 4 3 System overview 5 4 Installation 6 5 Connection 11 6 Maintenance

More information

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date: Documentation Fan cartridge for EtherCAT and Bus Terminals Version: Date: 1.5 2017-08-07 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...

More information

Installation and Maintenance

Installation and Maintenance Installation and Maintenance TT1000 TT3000 TT4000 Version 1.3 e-data GmbH 01.2009 Version 1.3 1-1 1 Usage 1-3 1.1 Protection Class and Protection Type... 1-3 1.2 Safety Measures... 1-3 1.3 Before Commissioning...

More information

DuoFern Multiple Wall Controller

DuoFern Multiple Wall Controller DuoFern Multiple Wall Controller 9494-1 Instruction manual for the electrical connection and for commissioning Item no. 3250 19 74 / Type: 9494-1 (surface-mounted with battery) VBD 663-2 (12.16) Dear Customer,

More information

Operating instructions Optical distance sensor. OID20x / / 2015

Operating instructions Optical distance sensor. OID20x / / 2015 Operating instructions Optical distance sensor OID20x 80228367 / 00 03 / 2015 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

Installation Manual BAK02

Installation Manual BAK02 Installation Manual BAK02 XXXXXXXX/10-02-2014 Attention. Before installing the equipment, carefully read the SAFETY WARNINGS contained in the package as they provide important instructions regarding the

More information

Operating instructions Safety sensor BNS About this document. Content

Operating instructions Safety sensor BNS About this document. Content Safety sensor BNS 0. About this document Operating instructions.............pages to 6 Original. Function This operating instructions manual provides all the information you need for the mounting, set-up

More information

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

HST -M2 Switching element with locking mechanism (Translation of Original Manual) Installation and Operating Manual for Components HST -M2 Switching element with locking mechanism (Translation of Original Manual) HST-M2 Ident.-No.: 10214 HST-M2 Ident.-No.: 10626 HST-M2 Ident.-No.: 10218

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

HST -M1 Switching element with locking mechanism (Translation of Original Manual)

HST -M1 Switching element with locking mechanism (Translation of Original Manual) Installation and Operating Manual for Components HST -M1 Switching element with locking mechanism (Translation of Original Manual) HST-M1 Ident. No.: 10213 HST-M1 Ident. No.: 10219 HST-M1, pictured Ident.

More information

Operating instructions Safety mats SMS 4 SMS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety mats SMS 4 SMS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... 6 Disassembly and disposal 6. Disassembly....6 6. Disposal...6 7 Appendix 7. Wiring example...7 Operating instructions.............pages to 8 Original 8 EU Declaration of conformity x.000 / 07.07 / v.a.

More information

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01 PNOZ m ES RS232 Configurable Control System PNOZmulti Operating Manual-1002701-EN-01 This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies

More information

Operating instructions Safety sensor BNS About this document. Content

Operating instructions Safety sensor BNS About this document. Content afety sensor B 120 1. About this document E Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting,

More information

LED-Illumination with Control Unit Ident.-No

LED-Illumination with Control Unit Ident.-No A HAAG-STREIT COMPANY MÖLLER-WEDEL OPTICAL GmbH, Rosengarten 10, D-22880 Wedel with Control Unit Ident.-No. 773 190 01 Valid from Hardware / Software Rev. / SN 1.0 IDENT.-NO. 217 321 09 Document Version

More information

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content 8 Appendix 8.1 Wiring examples...3 8.2 Integral System Diagnostics (ISD)....4 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101172890-

More information

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content 1. About this document DE Betriebsanleitung...............Seiten 1 bis 6 Übersetzung der Originalbetriebsanleitung 1.1 Function This operating instructions manual provides all the information you need

More information

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2 VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2 1 of 18 PREFACE Important Installation Information It is the purchasers responsibility to determine the suitability

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -... E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... Safety sensor BNS 0 Disassembly and disposal. Disassembly..... Disposal... 7 EU Declaration of conformity Operating instructions.............pages to Original x.000 / 09.08 / v.a. - 08- / Q / 08-09- /

More information

/ 2CKA001473B Technical Reference Manual Compact combination 1/1gang with T13 SSA-F-1.1.

/ 2CKA001473B Technical Reference Manual Compact combination 1/1gang with T13 SSA-F-1.1. 1473-1-8873 / 2CKA001473B8873 18.04.2016 Technical Reference Manual ABB-free@home Compact combination 1/1gang with T13 SSA-F-1.1.2-508 Table of contents Table of contents 1 Information on the manual...

More information

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010 Installation instructions RF-identification system with integrated AS-i slave UK DTSLF 704153 / 07 04 / 2010 Inhalt 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 2.1 General...4

More information

Vibration Sensor Type 640

Vibration Sensor Type 640 Vibration Sensor Type 640 Standard Zone-1-21 Zone-2-22 Instruction Manual English Instruction Manual Vibration Sensor Type 640 Standard Zone-1-21 Zone-2-22 Edition: 12.04.10 Attention! Before Start-Up

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230 USER MANUAL VIBRATION CONTROL Version 2.2 1 IMPORTANT NOTES Electrical danger within the meaning of this documentation or the warning labels on the product itself respectively means that death, serious

More information

Sliding shutter control Aluminium shutters

Sliding shutter control Aluminium shutters Sliding shutter control Aluminium shutters Operating and maintenance instructions FOR THE USER Valid from 09.2011 E 916.3 Notes These operating instructions describe how to operate the EHRET sliding shutter

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date: Documentation Sixteen Channel Digital Output Module with D-Sub Connector Version: Date: 2.0 2016-08-03 Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Safety

More information

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions , Equipment protection fuse with Ex mb II C Gb approval Geräteschutzsicherung mit Zulassung Ex mb II C Gb Fusible de protection d appareil avec homologation Ex mb II C Gb Example / Beispiel / Exemple:

More information

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016 Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6

More information

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06 PKP Prozessmesstechnik GmbH Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating manual PSA06 Electronical pressure switch Content Page 19-34 1. Foreword 19

More information

Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve

Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve FKE003 Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve Features Operation of electronic expansion valves pulsed via integrated electronic

More information

Technical Manual Room temperature controller

Technical Manual Room temperature controller 1473-1-8563 03.07.2014 Technical Manual Room temperature controller RTC-F-1 ABB-free@home Content 1 Notes on the instruction manual 3 2 Safety 4 2.1 Used symbols 4 2.2 Intended use 5 2.3 Improper use 5

More information

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions (PS) Fully Configurable Galvanic Isolator Operating Instructions Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized

More information

Installation manual plugs and connectors with screw connection (16/32 A)

Installation manual plugs and connectors with screw connection (16/32 A) EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

Operating instructions Optical distance sensor. OID20x / / 2014

Operating instructions Optical distance sensor. OID20x / / 2014 Operating instructions Optical distance sensor OID0x 800005 / 00 08 / 01 Contents 1 Preliminary note... 1.1 Symbols used... 1. Warning signs used... Safety instructions... Functions and features...5.1

More information

Operating instructions Safety switch with interlocking function AZM 200D. 1. About this document. Content

Operating instructions Safety switch with interlocking function AZM 200D. 1. About this document. Content 8 Appendix 8.1 Wiring example...6 8.2 Wiring configuration and connector accessories...7 9 EU Declaration of conformity Operating instructions.............pages 1 to 8 Original x.000 / 11.2017 / v.a. -

More information

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

Tina 1A Blanking plug

Tina 1A Blanking plug Original instructions Tina 1A Blanking plug ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating manual. GTL - Configuration tool. Please keep the manual for future use. Operating manual GTL - Configuration tool Please keep the manual for future use. V1.00-01 GREISINGER Electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax +49(0)9402-9383-33

More information

Assembly and Operating Instructions Tubular drives for sunshades

Assembly and Operating Instructions Tubular drives for sunshades R8/17C PS - L120/11C en Assembly and Operating Instructions Tubular drives for sunshades New: With pluggable Becker connecting cable Important information for: Fitters Electricians Users Please forward

More information

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002 S-5EC english Potentiometer 5-step Operating Instructions Keep for reference! Content 1 General notes............................................ 3 1.1 Structure of the operating instructions....................

More information

MDM 011-Z1 Regen Resistor

MDM 011-Z1 Regen Resistor MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18

More information

Assembly and Operating Instructions Door Control

Assembly and Operating Instructions Door Control S10 GB Assembly and Operating Instructions Door Control Important information for: Fitters Electricians Users Please forward accordingly! These instructions must be kept for future reference. Assembly

More information

Operating instructions

Operating instructions www.lehmann-locks.com GB L033-A01 L033-A02 M300 L033-A01 / -A02 Operating instructions Contents Page General description / Technical data / Safety instructions... 2 Care and maintenance / Factory settings

More information

Demonstration Case BENNING DB 1

Demonstration Case BENNING DB 1 Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...

More information

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document. 1. About this document Operating instructions.............pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Documentation. AL225x Connector-Box. Accessory for servo drives of the series AX5000 and AX2000. Version: Date:

Documentation. AL225x Connector-Box. Accessory for servo drives of the series AX5000 and AX2000. Version: Date: Documentation Accessory for servo drives of the series AX5000 and AX2000 Version: Date: 1.8 2018-01-16 Contents Contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Documentation Issue Status...

More information

Operating Instructions Wall saw WSE1217 USA

Operating Instructions Wall saw WSE1217 USA Operating Instructions Index 000 Original operating instructions 10992859 en / 25.04.2012 Congratulations! With a Hydrostress unit from TYROLIT, you have chosen a tried and tested piece of equipment which

More information

Operation Manual Locator Wöhler L 200

Operation Manual Locator Wöhler L 200 Operation Manual Locator Wöhler L 200 Best.-Nr. 22849 2014-12-18. Contents Contents 1 General Information... 3 1.1 Operation Manual Information... 3 1.2 Notes in this manual... 3 1.3 Proper use... 3 1.4

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Electronic Rotational Speed Monitoring Device Type EDO Device Identification No.: 93.045 508.001 /.005 /.007 /.012 OPERATING INSTRUCTIONS 2 CE-Sign an Conformity The device meets the requirements of the

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Operating instructions Position switches EX-Z/T G/D. 1. About this document. Content

Operating instructions Position switches EX-Z/T G/D. 1. About this document. Content 6 Disassembly and disposal 6.1 Disassembly....5 6.2 Disposal...5 7 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 08.2018 / v.a. - 101185191- / N / 2018-08-15

More information

Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS Product information Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS PI_GB_PES_PDS_Art0015689_1v0.doc 2 10/2005 In Table of contents Scope of delivery...3 Safety notices...3

More information

Operating instructions Hinge safety switch TESZ. 1. About this document. Content

Operating instructions Hinge safety switch TESZ. 1. About this document. Content 1. bout this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

MSI-RM2 Safety Relays

MSI-RM2 Safety Relays MSI-RM2 Safety Relays EN 2010/11-603021 We reserve the right to make technical changes SAFE IMPLEMENTATION AND OPERATION Original operating instructions Relay module for Optoelectronic Protective Devices

More information

Operating Instructions Drill rigs DRU400 DRA400

Operating Instructions Drill rigs DRU400 DRA400 Operating Instructions Drill rigs DRU400 DRA400 Index 001 Original operating instructions 10988838 en / 12.05.2017 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested

More information

Interface and Supply module. IPC 3x0i / PSC 3x0i

Interface and Supply module. IPC 3x0i / PSC 3x0i Interface and Supply module IPC 3x0i / PSC 3x0i Installation Guide Version 10 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.: +49 2241 9199801 53925 Kall Fax.: +49 2241 9199871 Germany www.ibs-batchcontrol.com

More information

Push button UP 287, 4 - fold

Push button UP 287, 4 - fold Product DELTA profil DELTA style Push button 1-fold pearl grey 5WG1 241-2AB01 titanium white 5WG1 285-2AB11 titanium white 5WG1 241-2AB11 basalt black 5WG1 285-2AB21 anthracite 5WG1 241-2AB21 titanium

More information

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating Manual -ENGLISH- Page 1 KWG-ISO Page 1 KWG-ISO Operating manual English- Status May 2013 Page 2 Manufacturer address KW-Generator GmbH & Co.KG Bänglesäcker 24 73527 Schwäbisch-Gmünd / Lindach Phone: +49 (0) 7171 104 17 0 Fax: +49 (0)

More information

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date: Documentation Sixteen channel digital output module with D-Sub Connector Version: Date: 2.0.0 2017-11-20 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

Operating instructions Safety switch with interlocking function MZM 100 B. 1. About this document. Content

Operating instructions Safety switch with interlocking function MZM 100 B. 1. About this document. Content 1. About this document Operating instructions............pages 1 to 10 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you

More information

Operating instructions Solenoid interlock AZM 200 T. 1. About this document. Content

Operating instructions Solenoid interlock AZM 200 T. 1. About this document. Content 7 Set-up and maintenance 7.1 Functional testing...7 7.2 Maintenance...7 Operating instructions............pages 1 to 10 Translation of the original operating instructions 8 Disassembly and disposal 8.1

More information

Weatherproof IR Color Day/Night Cameras

Weatherproof IR Color Day/Night Cameras Weatherproof IR Color Day/Night Cameras Products: CFC6042IR, CFC6042IR2, CFC6042IR3, CFC6043IR, CFC6043IR2, CFC6043IR3 Please read this manual before installing and using this camera and always follow

More information