1 MOBILE LABORATORY FOR ENVIRONMENTAL ANALYSIS EcoLAB AMBIENT AIR QUALITY MONITORING SYSTEMS AMBIENT AIR POLLUTANT ANALYZERS 1 AF22M UV Fluorescent Sulfur Dioxide Analyzer (H2S - SO2 Analyzer) SO2/H2S Ambient air monitoring Sulfur dioxide Indoor air monitoring Air quality and stack monitoring of petrochemical, pulp & paper plants, water treatment plants Continuous emissions monitoring (CEM) by dilution extraction Ranges: 0-0.1/ 0.2 / 0.5 /1 / 2 / 5 / 10 ppm or user selectable ranges Lower detectable limit (2s): 1 ppb Response time: automatic and programmable (minimum 10 sec) Zero drift: less than 0.5 ppb / 24 h less than 1 ppb / 7 days Span drift: less than 0.5 % / 24 h less than 1 % / 7 days Linearity: +_ 1 % of F.S. Graphic Liquid Crystal Display (LCD) Interactive menu driven software with enhanced speed display Real-time synoptic flow diagram display User programmable ranges and average times Auto-ranging Temperature and pressure compensation Automatic response time Real time calibration graph Built-in storage of two month average data (up to 12 months with the optional memory extension) Built-in double serial interface (RS232/RS422) for remote control and maintenance
2 2 AC32M-CNH3 Ammonia and nitrogen oxides analyzer (NO, NOx, NO2/NH3) Low level ammonia (NH3) monitoring in ambient air Odour continuous monitoring (wastewater plants, chemical industries) Workplace monitoring Ranges: / 0.25 / 0.50 / 1 ppm Lower detectable limit: ppm Span drift: < 1% / week (with zero cycle on) Response time: 180 seconds Span drift: < 1% / week Linearity: +/- 1% of full scale Graphic Liquid Crystal Display (LCD) Interactive menu driven software with enhanced speed display Real-time synoptic flow diagram display User programmable ranges and average times Auto-ranging Temperature and pressure compensation Automatic response time Real time calibration graph Built-in storage of one month average data (up to 6 months with the optional memory extension) Built-in double serial interface (RS232/RS422) for remote control and maintenance 3 CO12M Gas Filter Correlation Carbon Monoxide Analyzer (CO) Ambient air monitoring Mobile laboratory Continuous emissions monitoring (CEM) by dilution extraction Ranges: 0-10/ 25 / 50 /100 / 200 ppm or user selectable ranges Lower detectable limit (2s): 50 ppb Response time: automatic and programmable (minimum 30 sec) Zero drift: less than 0.1 ppm / 24 h less than 0.1 ppm / 7 days Span drift: less than 1% / 24 h less than 1% / 7 days
3 Graphic Liquid Crystal Display (LCD) Interactive menu driven software with enhanced speed display Real-time synoptic flow diagram display User programmable ranges and average times Auto-ranging Temperature and pressure compensation Automatic response time Real time calibration graph Built-in storage of two month average data (up to 12 months with the optional memory extension) Built-in double serial interface (RS232/RS422) for remote control and maintenance 4 O342M UV Absorption Ozone Analyzer Ozone Ambient air monitoring Indoor air monitoring Mobile laboratory Laboratory and field studies on the effects of ozone Ranges : 0-0.1/ 0.2 / 0.5 /1 / 2 / 5 / 10 ppm or user selectable ranges Lower detectable limit : 0.4 ppb Response time : automatic and programmable (minimum 20 sec) Zero drift : less than 0.5 ppb / 24 h less than 1 ppb / 7 days Span drift : less than 0.5 % / 24 h less than 1 % Graphic Liquid Crystal Display (LCD) Interactive menu driven software with enhanced speed display Real-time synoptic flow diagram display User programmable ranges and average times Autoranging Automatic response time Real time calibration graph Built-in storage of two months average data (up to 1 year with the optional memory extension) Built-in double serial interface (RS 232/RS 422) for remote maintenance 5 HC51M Total VOC FID Hydrocarbon (CH4, HCnm, HCT) Analyzer Ambient air monitoring Monitoring around industrial sources emitting VOCs
4 Continuous emissions monitoring (CEM) by dilution extraction Measurement of impurities in industrial gases Programmable measurement ranges: 0-10 / 50 / 100 / 500 / 1,000 ppm, or user selectable Lower detectable limit: 0.05 ppm Response time: automatic or programmable Zero drift: 0.1 ppm / 7 days Span drift: < 1 % / 7 days Linearity: ± 1 % full scale High sensitivity, stable, linear FID detector Temperature controlled pneumatics Graphic Liquid Crystal Display (LCD) Interactive menu driven software Synoptic flow diagram display Remote troubleshooting diagnostics Auto-ranging Automatic response time Real time calibration graph Built-in serial interface (RS232/RS422) Built-in storage of the last 1500 average data 6 VOC72M Gas Chromatography Volatil Organic Compounds (BTEX) Analyzer Ambient air monitoring Monitoring of industrial sources emitting VOCs Photochemical pollution studies (stationary and mobile laboratories) Measured compounds: Benzene, Toluene, Ethylbenzene, m+p-xylene, o-xylene (other compounds on request) Measuring ranges: maximum 1000μg/m3 (programmable) Units: ppb or μg/m3 (programmable) Cycle duration: 10, 12, 15, 20, 30 minutes (programmable). Specifications are based on 15 min cycle. Measuring noise (s): 0.025μg/m3 at 0.5μg/m3 benzene Lower detectable limit (2s): 0.05μg/m3 benzene Carry-over (memory effect): 0.5% on the first zero Long-term span drift: 4% on 15 days
5 Lack of fit; largest residual: 4% of the measured value Repeatability standard deviation: 0.05μg/m3 at 5μg/m3 benzene (<1% of the annual limit) Sample flow: 50ml/minute Flow control: integrated vacuum pump + heated micro capillary tube Trap adsorbent: Carbopack Sampling temperature: 35 C Desorption temperature / heating rate: 380 C (programmable) / > 160 C/second Injection valve: 6-port (heated) GC column: stainless steel 15m x 0.25mm x 1μm apolar Carrier gas control: electronic pressure control Temperature control: C ± 0.1 C. 5 ramps up to 30 C/minute. Cooling: liquid heat exchanger and thermo-electric cooler GC detector: Photo-ionisation (PID) 10,6eV with nitrogen curtain Detector's temperature: 140 C (programmable) Gas supply: Nitrogen 6.0 ( %) 3.2 ± 0.2 bar 15 ml/minute Display: LCD 240 x 128 text and graphic mode Serial link: RS232 or RS422 Ethernet port: RJ45 socket, UDP protocol USB port: USB socket format 1.0 Dimensions: (LxWxH): 601 mm x 483 mm x 133 mm Weight: 12.5 kg Electrical consumption: average: 130VA, peak 200VA, stand-by 50VA Power supply: V + ground ; 50 60Hz Operating temperature: + 5 C to + 35 C Robust and low maintenance instrument, (no PID lamp cleaning) Ready to use in less than 30 minutes Performs all the functions, such as: sampling, analysis and data management, in a simple and completely autonomous mode Quick check of the chromatogram peaks possible directly on-screen, without the use of a computer Memory effect (up to 10 times lower than required by the standard EN ) allowing the automatic calibration of the analyser on a single cycle without an external PC GC column equipped with an innovative liquid-cooler; retention times are stable even with a fluctuating temperature Ultrafast trap heater (heating rate >160 C/second) Remote diagnosis, made possible without opening the hood Replacement of the trap in less than 2 minutes. No adjustment required Use of a single gas source (nitrogen) 3 levels of built-in security Equipped with LCD screen
6 High sensitivity, stable and linear response PID detector Long-life capillary column Self-contained and completely automated Synoptic flow diagram display TUV Compliant following EN MP101M Particulate Analyzer and automatic sampler Ambient air quality monitoring Indoor dust monitoring Working places Industrial areas Measurement ranges: / / / / / / µg/m3. Cycle time: 1/ 4, 1/ 2, 1, 2, 3, 6, 12, 24 h selectable Source: sealed Carbon 14, half lifetime: 5000 years, low activity: < 3.33 MBq (90 µci) True particulate concentration measurement, not influenced by the physico-chemical nature, color or shape of particulates Exclusive temperature-regulated sampling tube to avoid artefacts on the filter (evaporative losses of semi-volatile particulate matter during sampling...) Built-in reference gauge for calibration Selectable enhanced TSP, PM10, PM2.5, PM1 sampling inlets Low activity 14C sealed flat source usable in most Flow regulation by high precision differential pressure measurement Graphic Liquid Crystal Display (LCD) Interactive menu-driven software, with enhanced speed display Enhanced time resolution for daily floating average and continuous dust temporal trend evaluation Ethernet and USB connectivity for data retrieval and software upgrade by direct Flash EPROM application
7 8 SONIMIX 3080 Hydrogen and Zero Air Generators 9 Double 36U rack cabinet The SONIMIX 3080 is an instrument composed of an Hydrogen generator as well as a self regenerable Zero Air generator. The two modules are complementary and make this instrument an indispensable tool for the alimentation in Air and Hydrogen of all FID, BTEX, VOC and gas chromatographs. The utilisation of the SONIMIX 3080 avoid the use of two cumbersome and expensive gas cylinders. The instrument internal program and processor assure the control of both generators and allow to check on line various functioning s parameters such as: water level, pressure outlet (H2 and AIR), electrolyses current, CH4 oven temperature (if option 11 installed). The display and keyboard allow a simple and intuitive use of the instrument. The functioning parameters and the alarm can be monitored through the RS 232 remote command as well as through one dry relay. 10 AIR AMBIENT SAMPLING HEAD The quality of analysis is always depending of the representativity of the sampling. These sampling heads are in conformity with US EPA and European specifications. Telescopic head SMT Forced aspiration (residence time < 5s). Body stainless steel with internal PFA tube. Sampling manifold for 6 analyzers. Anti-precipitation and anti-insects net in PTFE (Teflon). 220V/50Hz / 110V/50/60Hz. Life of pump > h.
8 DATA ACQUISITION & CENTRALIZATION SYSTEM 11 SAM-WI Data acquisition system Ambient air Acquisition of instantaneous measurements at a programmable frequency ranging from 5 seconds up to 24 hours Management of the metrological context: analysers' parameters and internal defects, technical measurements, external signals (door open, flow, etc.) Controls of lower and higher validity limits, sensitivity threshold, immobility, slope and follow-up of peak episodes Management of power-up and analysers maintenance mode (pre-heating parameter setting, automatic calibration) Variable aggregation period Variable aggregation period Data aggregation kinds: arithmetic mean, vector average, sum, linearization, unit conversion Association of a quality code to each value Evaluation of quality indicators for each data: min, max, standard deviation, the number of over-thresholds, data representativity Calculations of the number of consecutive over-thresholds for values or of moving average to detect alarms (6 thresholds) Manages the acquisition of data originating from various measuring devices Pilots the instruments and ensures they are operating correctly Sets a Quality Code to each produced measurement Records all events Detects the dysfunctions of the instrumentation Supervises the measured levels Signals any over threshold 12 XR PREMIUM SOFTWARE Ambient air networks Up to 999 active stations Distributed with communications capacities over analogical and digital telephone lines, GSM, GPRS, leased line or direct connection Management of telephone lines sets
9 Complete parameters setting and remote control of the acquisition system Programmable periodic calls or on request calls to acquisition systems Reading of the incorporated data, the log book, the calibration history, the configuration and the acquisition system status Reception and decoding of the spontaneous calls from the acquisition Systems on advent of, for example, defects or over-thresholds Automatic warning by mail, fax, SMS, voice, etc Graphic follow-up in real time of acquisition data and of all the internal parameters of the acquisition system and of the measuring devices Automatic archiving of data in the data base Aggregation of data hourly, daily, monthly, etc Cartographic representation with animation capability Data display in table or graphic form Data control and validation Data processing and report printing System administration and security centralizes all data delivered by measuring devices integrates the data in an information processing system in order to display it in a way facilitating their consultation and processing configures and drives sets of measuring devices (acquisition systems, analysers, communication systems) allows the technical follow-up of all installations ensures the traceability of data, events and technical information controls data quality and guarantees its integrity detects and signals any event (dysfunctions, pollution episodes, etc.) possess a set of tools for data storage, treatment, presentation and diffusion 13 Chassis The basic types of chassis used are: Mercedes Sprinter, Iveco Daily, Fiat Ducato, Volkswagen Crafter etc. VEHICLE
10 Contact information: Tel.: ; Fax: , Mob.: , For letter: P.O.Box 41016, Larnaca 6308, Cyprus Factory: Larnaka, Cyprus
MICRO GC FUSION Micro GC Fusion 3/17/2014 1
MICRO GC FUSION 1 Micro GC Fusion The Next Generation Micro GC 2 Builds on an Innovative Tradition 3000 Micro GC Micro GC Fusion MTI Micro GC 3 Micro GC Fusion Feature Highlight New Chassis Design Aesthetic,
More informationCO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O
Product Data Sheet CODEL Continuous Emission Monitoring GCEM4000 Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O In-situ, low maintenance devices for continuous process and emissions
More informationAn Improved Compact GC For Field Testing
An Improved Compact GC For Field Testing NovaTest P300 Integrated Compact Gas Chromatograph Nanova Environmental, Inc. 1 VOCS ARE EVERYWHERE Do you think volatile organic compounds (VOCs) only exist in
More informationCO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. In-situ low cost, low maintenance devices for continuous process and emissions monitoring.
Product Data Sheet Continuous Emission Monitoring GCEM 40 Series Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O In-situ low cost, low maintenance devices for continuous process and emissions
More informationABB Analytical ABB Process Analytics. VistaII. Model 2000 Process Gas Chromatograph
ABB Analytical ABB Process Analytics VistaII Model 2000 Process Gas Chromatograph A better gas chromatograph...built on a foundation of leadership ABB Process Analytics manufactured and sold the first
More informationContinuous Ambient Air Quality Monitoring Systems Challenges & Recent Advances
Continuous Ambient Air Quality Monitoring Systems Challenges & Recent Advances Managing Industrial Air Emissions 21 st February 2018 1 Challenge to select the correct Continuous Ambient Air Quality Monitoring
More informationContinuous Flow Monitoring
Product Data Sheet CODEL Continuous Flow Monitoring VCEM5000/5100 Flue Gas Flow Monitor In-situ, low maintenance devices for continuous measurement of hot gas flow Non-contact infra-red sensing Continuous
More informationOperating Manual. Gas chromatograph GC 5000 BTX
Operating Manual Gas chromatograph GC 5000 BTX Address of manufacturer: AMA Instruments GmbH Soeflinger Straße 100 89077 Ulm, Germany Tel +49 731 933-2100 Fax +49 731 933-2110 Imprint: Operating Manual
More informationSoprane II Documentation
Soprane II Documentation p. 1 / 198 Table of contents 1. INTRODUCTION 6 2. INSTALLATION 6 3. ANALYZER CONFIGURATION 8 3.1. Creation 9 3.1.1. Analyzer creation with network connection 11 3.1.2. Analyzer
More informationMODEL 42C High Level
MODEL 42C High Level CHEMILUMINESCENCE NO-NO 2 -NO x ANALYZER INSTRUCTION MANUAL P/N 100175-00 THERMO ELECTRON CORPORATION ENVIRONMENTAL INSTRUMENTS 27 FORGE PARKWAY FRANKLIN MASSACHUSETTS 02038 (866)
More informationG460 Multi-gas Detector
CH 3 SH, C 2 H 4 O, Cl 2, ClO 2, CO, CO 2, COCl 2, Combustible (Catalytic), Combustible (Infrared),, HCl, HCN, HF, S, NH 3, NO, NO 2, O 2, O 3, PH 3, PID (VOC), SiH 4, SO 2, THT The G460 is a rugged, compact
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the T200, T204 & 200E Chemiluminescent NOx Analyser manufactured by: Teledyne API 9480 Carroll Park Drive San Diego California 92121-5201 USA has
More informationMCS 100 E. Compact IR Photometer for Stack Gas Monitoring
P R O D U C T I N F O R M A T I O N MCS 100 E Compact IR Photometer for Stack Gas Monitoring Modern Emission Measuring Technology: Compact Stack Gas Monitoring The MCS 100 E is an extremely compact multi-component
More information42iQLS Instruction Manual
42iQLS Instruction Manual Low Source NO-NO 2 -NO x Analyzer 117436-00 15Jan2018 Contents Chapter 1 Chapter 2 Chapter 3 Introduction... 1-1 iq Series Instrument Platform... 1-1 Principle of Operation...
More informationAPPLICATIONS. Boiler / Burners Turbines Engines Incinerators Process Control Landfills Cogeneration plants
The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications The IMR 5000 is a stand-alone analyzer that works automatically.
More informationLaboratory-precise analysis, anywhere. PORTABLE GAS ANALYZER PG-350 E
PORTABLE GAS ANALYZER Laboratory-precise analysis, anywhere. PORTABLE GAS ANALYZER NOX - SO2 - CO - CO2 - O2 According to: DIN EN 5267-3, DIN EN 48 Approved as Standard Reference Method (SRM) for: CO (DIN
More informationSepacore X10 / X50 system Technical data sheet
Sepacore X10 / X50 system Technical data sheet Sepacore X10 and X50 flash chromatography systems address most requirements for the purification of organic compounds. Whether a crude synthesis mixture or
More informationImplementation of a PC-based data-logger software for air pollution monitoring networks
Air Pollution XIII 455 Implementation of a PC-based data-logger software for air pollution monitoring networks G. Latini 1, L. Magnaterra 1, S. Tascini 1 & G. Cencioni 2 1 Dipartimento di Energetica Università
More informationIndustrial pressure controller Model CPC4000
Calibration technology Industrial pressure controller Model CPC4000 WIKA data sheet CT 27.40 Applications Oil and gas industry Industry (laboratory, workshop and production) Transmitter and pressure gauge
More informationOperation of the Toxic Organic Chemical Air Monitor (TOCAM ) with the Ellvin Chromatography Software
Operation of the Toxic Organic Chemical Air Monitor (TOCAM ) with the Ellvin Chromatography Software April 13, 2015 Defiant Technologies, Inc. TOCAM(R) 1 Basic Parts of the Toxic Organic Chemical Air Monitor
More informationPrimary Reference Materials
Primary Reference Materials 2016 Gas standards VSL provides the following types of gas standards Primary reference materials Certified reference materials Calibrated gas mixtures All gas standards are
More informationSensor for car parks and tunnels
Page 1 Sep. 2017 system with exchangeable sensor element including digital value processing, temperature compensation and selfmonitoring algorithm for the continuous sensing and control of the ambient
More informationProduct Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102
Product Catalog 2018 senseware.co 571.766.6443 1775 Tysons Boulevard Floor 5 Tysons VA, 22102 TABLE OF CONTENTS Senseware Base Hardware..................................... 2 Environmental Sensors......................................
More informationStandard Operating Procedure
1 of 7 Prepared by: Reviewed by: Approved by: Date: Date: Date: The colored ink stamp indicates this is a controlled document. Absence of color indicates this copy is not controlled and will not receive
More informationContinuous Dew Measurement in Explosive Area for flammable and non-flammable gases. VASTHI ENGINEERS
Sheet No. 1 of 5 Continuous Dew Measurement in Explosive Area for flammable and non-flammable gases. Sheet No. 2 of 5 Vasthi Engineers Moisture Analyzer Model VMA 888 is heavy duty, industrial hygrometer
More informationCTC Low Temperature Process Chillers
INNOVATE DESIGN APPLY CTC Low Temperature Process Chillers 5-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough When it comes to process cooling, every application is unique in
More informationMODEL 43C INSTRUCTION MANUAL P/N THERMO ELECTRON CORPORATION ENVIRONMENTAL INSTRUMENTS 27 FORGE PARKWAY FRANKLIN MASSACHUSETTS 02038
MODEL 43C PULSED FLUORESCENCE SO 2 ANALYZER INSTRUCTION MANUAL P/N 100100-00 THERMO ELECTRON CORPORATION ENVIRONMENTAL INSTRUMENTS 27 FORGE PARKWAY FRANKLIN MASSACHUSETTS 02038 (866) 282-0430 Toll Free
More informationEnvironmental Equipment, Inc.
Environmental Equipment, Inc. 3634 Central Ave., St. Petersburg, FL 33711 USA Phone: 1-800-746-4467 / 727-328-2818 www.imrusa.com Email: info@imrusa.com IMR 2800P Portable combustion gas analyzer Simultaneous
More informationEAG SYSTEM SIGNAL ACQUISITION SYSTEMS
EAG SYSTEM SYNTECH is an Original Equipment Manufacturer dedicated to the design and production of instruments for electrophysiological and behavioural research, particularly for the study of insect chemoreception
More informationSS3000e DUAL CHANNEL H2O GAS ANALYZER KEY FEATURES NEW FEATURES. FOR NATURAL GAS Product Code 10805
SS3000e DUAL CHANNEL H2O GAS ANALYZER FOR NATURAL GAS Product Code 10805 KEY FEATURES Virtually maintenance free No interference from glycol, methanol or amine contaminants (vapor phase) Accurate, real-time
More informationSWISS MADE. Series 320 XT PREMIUM. Analytical. Precision
SWISS MADE PREMIUM Series Analytical Precision PREMIUM Series The Precisa 320 high performance series combines precision and quality, and offers the highest metrological performance and advanced integrated
More informationHeat Value Gas Chromatograph ISO standard version
No. SS2-HGC303-0100 Heat Value Gas Chromatograph ISO standard version OVERVIEW The model HGC303 is the world smallest gas chromatograph, which is capable of analyzing 11 different components of natural
More informationMulti-channel measurement technology to measure CO, NO & Visibility in one compact sensor
Product Data Sheet CODEL TunnelCraft 3 - Air Quality Monitor CO, NO & Visibility Low-cost Precision Tunnel Sensors Multi-channel measurement technology to measure CO, NO & Visibility in one compact sensor
More informationDGS-NO August 2017
Digital Gas Sensor Nitrogen Dioxide DGS-NO2 968-043 NITROGEN DIOXIDE APPLICATIONS Air Purification Control Air Quality Monitoring Industrial Safety Sensing BENEFITS Low Power 100 μw in standby mode Calibrated
More informationProcess Gas Chromatograph
Product Data Sheet RAI-PDS-GC-500 Model 500 Process Gas Chromatograph The Model 500 Process Gas Chromatograph is an advanced combination of technology and rugged instrumentation that helps make the most
More informationPneumatic precision pressure controller Model CPC6000
Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers
More informationSimplified Digital Connectivity using MODBUS TCP/IP for iseries Instruments. MODBUS Master Device (PLC, PC, Data logger, etc)
Simplified Digital Connectivity using MODBUS TCP/IP for iseries Instruments August 20, 2009 The Thermo Scientific line of iseries instruments has advanced communication features that can be utilized with
More informationD-R300 / D-R320 / D-R 800 DATASHEET
D-R300 / D-R320 / D-R 800 DATASHEET JUNHO 2013 Measuring principle The D-R 300 / D-R 300-40 meters operate according to the scattered light method. The modulated light from a Halogen lamp illuminates the
More informationModel VDL 115 Vacuum drying chambers for flammable solvents
Model VDL 115 Vacuum drying chambers for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber
More informationProcess Gas Chromatograph PGC1000
Data Sheet Process Gas Chromatograph PGC1000 Analyzer Products Field Mounted GC DESCRIPTION The PGC1000 is a field mounted GC using two analytical trains per analyzer that enable measurements of C1 thru
More informationMoisture Analyzers EM 120-HR
SWISS MADE Moisture Analyzers EM 120-HR EXECUTIVE PRO Series 330 XM High Resolution Precision EXECUTIVE PRO Series 330 XM With model EM 120-HR, Precisa is setting new standards in the demanding area of
More informationNIR Moisture Analyzer KB-30
NIR Moisture Analyzer KB-30 Operation Manual Safety Precautions FPL950701 Improper use of the NIR moisture analyzer in violation of the following safety notes may result in death, injury or damage to property
More informationMOVING FROM PIPELINE TO PROCESS APPLICATIONS
MOVING FROM PIPELINE TO PROCESS APPLICATIONS HIGHER RELIABILITY LOWER MAINTENANCE OUT-OF-BOX STARTUP CERTIFICATE QSR-16 9720 OLD KATY ROAD HOUSTON, TEXAS 77055 USA 19203 HEMPSTEAD HOUSTON, TEXAS 77065
More informationPneumatic precision pressure controller Model CPC6000
Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers
More informationProcess Gas Chromatograph
Product Data Sheet PDS 103-700.A01 October 2005 Model 700 Process Gas Chromatograph The Model 700 Process Gas Chromatograph is an advanced combination of technology and rugged instrumentation that helps
More information42iQD Instruction Manual
42iQD Instruction Manual NO x Analyzer 119013-00 27Sep2018 Contents Chapter 1 Chapter 2 Chapter 3 Introduction... 1-1 iq Series Instrument Platform... 1-1 Principle of Operation... 1-3 Specifications...
More informationtesto 350 Flue gas analyzer Short manual
testo 350 Flue gas analyzer Short manual 2 1 Contents 1 Contents 1 Contents...3 1.1. Technical data...4 1.1.1. Measurement ranges and resolution...4 1.1.2. Other instrument data...5 2 Product description...6
More informationUSER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020
USER MANUAL MULTI COLOR MODEL : ARC2020 ACCSYS ELECTRONICS 140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD, GERUGAMBAKKAM, CHENNAI - 600122 Tel: 044 60505599 / 60505511 E-mail : sales@accsyselectronics.com
More informationRefrigerated incubators with forced convection
KB series (E3.1) Incubators Refrigerated incubators with forced convection The most versatile incubator for microorganisms: The BINDER KB series controls a temperature range of -5 C to 100 C. With its
More informationPneumatic precision pressure controller Model CPC6000
Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers
More informationPneumatic Precision Pressure Controller Model CPC6000
Calibration Technology Pneumatic Precision Pressure Controller Model CPC6000 R WIKA Data Sheet CT 27.61 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture Calibration
More informationPneumatic High-Speed Pressure Controller Model CPC3000
Calibration Technology Pneumatic High-Speed Pressure Controller Model CPC3000 WIKA Data Sheet CT 27.55 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture Calibration
More informationST-601 Inline ClO2 Concentration Monitoring Probe Instruction Manual
Pyxis Lab, Inc. ST-601 Inline ClO2 Concentration Monitoring Probe Instruction Manual Version 1.1 Pyxis Lab, Inc. 120 Jeffrey Ave Holliston, MA 01746 USA www.pyxis-lab.com service@pyxis-lab.com 1. Introduction
More informationDISSOLVED OXYGEN MEASUREMENT
DISSOLVED OXYGEN MEASUREMENT ACTEON 2030 TRANSMITTER Potentiometric measurement technology Robust, watertight, easy to install, Widescreen graphic display: instant measurements, trend line, relay state,
More informationSWISS MADE EXECUTIVE. Series 360 ES
SWISS MADE EXECUTIVE Series 360 ES Semi-micro Analytical Precision EXECUTIVE Precisa 360 ES With the 360 series, Precisa is setting new standards in the demanding area of high-end laboratory balances:
More informationDGS-NO August 2017
Digital Gas Sensor Nitrogen Dioxide DGS-NO2 968-043 NITROGEN DIOXIDE APPLICATIONS Air Purification Control Air Quality Monitoring Industrial Safety Sensing BENEFITS Low Power 1 mw @ 1 minute sampling Calibrated
More informationUser Manual SERVOPRO FID PROCESS ANALYSERS. Trace Total Hydrocarbons in Argon, Oxygen, Nitrogen, Air Helium or Carbon Dioxide
PROCESS ANALYSERS SERVOPRO FID Trace Total Hydrocarbons in Argon, Oxygen, Nitrogen, Air Helium or Carbon Dioxide User Manual Part Number: 01000001A Revision: 4 Language: UK English This page intentionally
More informationIRIDIUM INTELLIGENT MODULAR FLEXIBLE SERIES FLOW CONTROL C1 Configuration Liquid Applications
IRIDIUM SERIES FLOW CONTROL 6010-01-C1 Configuration Liquid Applications INTELLIGENT MODULAR FLEXIBLE WHAT IS IRIDIUM FLOW CONTROL? Iridium is a platform for configurable flow control. Its modular design
More informationSWISS MADE EXECUTIVE. Precisa 360 ES
SWISS MADE EXECUTIVE Precisa 360 ES Semi-micro Analytical Precision EXECUTIVE Precisa 360 ES With the 360 series, Precisa is setting new standards in the demanding area of high-end laboratory balances:
More informationSepacoreControl Software data sheet
SepacoreControl Software data sheet The software is able to control the Sepacore flash X and X5 chromatography system. Designed and developed with and for laboratories, the software is intuitive, easy
More informationMODEL 320 HEATED NON-METHANE HYDROCARBON CUTTER OPERATING MANUAL
MODEL 320 HEATED NON-METHANE HYDROCARBON CUTTER OPERATING MANUAL The Signal Instrument Company Limited 12 Doman Road, Camberley Surrey, GU15 3DF England Tel: +44 (0) 1276 682841 Fax: +44 (0) 1276 691302
More informationCompressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture
Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture Residual oil content measurement OIL-Check 400 For permanent and highly precise measurement of the vaporous
More informationModel KB 400 Cooling incubators with compressor technology
Model KB 400 Cooling incubators with compressor technology BENEFITS Safe and reproducible incubation conditions even at high environmental conditions Disinfection routine at 100 C MAIN FEATURES Model 400
More informationStandard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser.
The UltiMate Solvent Organizer 3.9 Specifications 3.9.1 Solvent Organizer Reservoirs Solvent Degassing Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter.
More informationProduct Specification. CO 2 Engine ICB. Sensor module for bio applications
Product Specification CO 2 Engine ICB Sensor module for bio applications General CO 2 Engine ICB is targeted on bio applications with required measurement range 0 to up to 30% vol CO 2. This document contains
More information49iQPS Instruction Manual. Ozone Primary Standard
49iQPS Instruction Manual Ozone Primary Standard 117434-00 27Sep2018 Contents Chapter 1 Chapter 2 Chapter 3 Introduction... 1-1 iq Series Instrument Platform... 1-1 Principle of Operation... 1-3 Specifications...
More informationSAFE work sense. white paper The solution to manage safety, energy saving and working hours in manufacturing and industry.
SAFE work sense The solution to manage safety, energy saving and working hours in manufacturing and industry. white paper 2014 Auroras S.r.l. - via Paolo Gorini - 26845 Codogno (LO) Italy tel. e fax 0377
More informationHigh-speed peumatic pressure controller Model CPC3000
Calibration technology High-speed peumatic pressure controller Model CPC3000 WIKA data sheet CT 27.55 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers
More informationModel 43i. Instruction Manual Pulsed Fluorescence SO2 Analyzer Part number Oct2005
Model 43i Instruction Manual Pulsed Fluorescence SO2 Analyzer Part number 101589-00 17Oct2005 2005 Thermo Electron Corporation. All rights reserved. Analyze. Detect. Measure. Control is a trademark of
More informationKRAL Electronics BEM 300 and BEM 500.
KRAL Electronics BEM 300 and BEM 500. KRAL Electronics BEM 300 and BEM 500 Electronic units that are coordinated to KRAL flowmeters and their diverse applications. Coordinated to the flowmeters and their
More informationIsotemp. Bath Circulators. Improve the productivity. of your lab with solutions. from Fisher Scientific
Isotemp Bath Circulators Improve the productivity of your lab with solutions from Fisher Scientific I s o t e m p B a t h Isotemp Refrigerated and Heating Bath Circulators Three Controller Choices: Programmable,
More informationHGC Data Manager. Model HDM303 OVERVIEW FEATURES. No. SS2-HDM (Rev.3)
HGC Data Manager Model HDM303 OVERVIEW HGC Data Manager (HDM) is a powerful HGC family component, which adds valuable data management function to the analyzer. Model HDM303 is Fieldbus device and is completed
More informationPneumatic precision pressure controller Model CPC6000
Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers
More informationUSER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series
USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097 Tele fax : +91-44-24581758,Mobil
More informationWASTEWATER DISINFECTION FILTERED IN-PIPE TREATMENT
WASTEWATER DISINFECTION FILTERED IN-PIPE TREATMENT Proven TrojanUV Closed-Vessel Chambers for Reuse Disinfection. Validated, chemical-free disinfection from the industry leader Around the globe, wastewater
More informationGas Analyzers Components for Gas Analysis
2.2 2 Contents Modular Gas Analyzer DX6100 Series.......................................23 Advantages...........................................................23 Design Features.........................................................24
More informationOver. Year of Service. 2017/2018 Product Catalog. Chromatography. Research Supplies
Over 25 Year of Service 2017/2018 Product Catalog Chromatography Research Supplies Since 1991, Chromatography Research Supplies, Inc. (CRS) has become known worldwide as a leading manufacturer and innovator
More informationSWISS MADE EXECUTIVE PRO. Precisa 360 EP
SWISS MADE EXECUTIVE PRO Precisa 360 EP Semi-micro Analytical Precision RZ_Precisa_360EP_041108.indd 3 4.11.2008 17:09:49 Uhr EXECUTIVE PRO Precisa 360 EP With the 360 EP series, Precisa is setting new
More informationDMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9
Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration service companies and service industry Research and development laboratories National
More informationtesto 350 Combustion & Emission Analyzer Short manual
testo 350 Combustion & Emission Analyzer Short manual 2 1 Contents 1 Contents...3 1.1. Technical data...4 1.1.1. Measurement ranges and resolution...4 1.1.2. Other instrument data...5 2 Product description...6
More informationAgilent 1260 Infinity Diode Array Detector
Agilent 126 Infinity Diode Array Detector Features, Technical Details, Specifications and Ordering Details 1 x higher sensitivity for HPLC and RRLC The Agilent 126 Infinity Diode Array Detector (DAD) features
More informationfor Advanced Environmental Measurements
Harnessing the Power of Mobile Computers for Advanced Environmental Measurements 6 DIRECT SENSE IAQ Indoor Air Quality Monitor DIRECTSENSE TM IAQ INDOOR AIR QUALITY MONITOR GrayWolf is changing the way
More informationHigh-end pressure controller Model CPC8000
Calibration technology High-end pressure controller Model CPC8000 WIKA data sheet CT 28.01 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration
More informationAutomated High Pressure Calibrator Model CPC 8000
Calibration Technology Automated High Pressure Calibrator Model CPC 8000 Mensor Data Sheet CPC 8000 02/2012 Applications Calibration of industrial pressure instruments Pressure transmitter manufacturers
More informationDatasheet.
Industrial Test & Mixing Equipment Bringing Test Innovation to you Datasheet This product datasheet has been provided by John Godrich & SJ Electronics in Partnership with BINDER www.johngodrich.co.uk www.sjelectronics.co.uk
More information3000HM HEATED TOTAL HYDROCARBON ANALYSER OPERATING MANUAL
3000HM HEATED TOTAL HYDROCARBON ANALYSER OPERATING MANUAL The Signal Instrument Company Limited 12 Doman Road, Camberley Surrey, GU15 3DF England Tel: +44 (0) 1276 682841 Fax: +44 (0) 1276 691302 Part
More informationHITACHI LACHROM ELITE
HITACHI LACHROM ELITE Clarity Control Module ENG Code/Rev.: M133/60D Date: 7/16/2018 Phone: +420 251 013 400 DataApex Ltd. Fax: +420 251 013 401 Petrzilkova 2583/13 clarity@dataapex.com 158 00 Prague 5
More informationHigh-Precision Pneumatic Pressure Controller Series CPC8000-L/-X
R Calibration Technology High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X WIKA Data Sheet CT 28.01 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture
More informationSoftware Manual. MLT Analyzer. MLT Analyzer Module
Rosemount Analytical NGA 2000 Software Manual MLT Analyzer MLT Analyzer Module (combined with NGA 2000 platform / MLT analyzer / TFID analyzer or customer-developed control unit) Software Version 3.3.X
More informationAir Monitoring Directive CHAPTER 6: AMBIENT DATA QUALITY for verification and validation of continuous ambient air quality data
Air Monitoring Directive CHAPTER 6: AMBIENT DATA QUALITY for verification and validation of continuous ambient air quality data (referred to as the Data Quality Chapter of the Air Monitoring Directive)
More informationDetailed procedures, operation instructions, maintenance, and emergency contact information list is attached.
GC/FID Standard Operating Procedure Environmental health and Safety (EH&S) 2809 Daley Drive Ames, IA 50011-3660 Phone: (515)-294-5359 Fax: (515)-294-9357 www.ehs.iastate.edu Procedure: Department: Bioeconomy
More informationDissolution Automation: Off line Systems
Dissolution Automation: Off line Systems Designed specifically for Tablet Dissolution testing, this unique versatile system allows samples to be collected over very short Time Intervals with additional
More informationDanalyzer Model 2350A. Gas Chromatograph Controller
Danalyzer Model 2350A Gas Chromatograph Controller For more than 75 years, Daniel Measurement and Control has brought acclaimed gas and liquid fiscal flow measurement products, services, and systems to
More informationMercury Tracker-3000 XS
Member of the envea Group Mercury Tracker-3000 XS Portable Instrument for Measuring Mercury in Air and Other Gases The new Mercury Tracker-3000 XS lighter - smaller - more comfortable We updated the well-proven
More informationAir Monitoring Directive Chapter 6: Ambient Data Quality
Air Monitoring Directive Chapter 6: Ambient Data Quality Version Dec 16, 2016 Amends the original Air Monitoring Directive published June, 1989 Title: Air Monitoring Directive Chapter 6: Ambient Data Quality
More information8241 Silica Monitor. Cost-effective automated monitoring of silica in a wide range of applications
Data sheet DS/8241 EN Rev. K 8241 Silica Monitor Cost-effective automated monitoring of silica in a wide range of applications Continuous sample reaction ensures optimum speed of response Fully dynamic
More informationPrecision pressure indicator 1- or 2-channel version Model CPG2500
Calibration technology Precision pressure indicator 1- or 2-channel version Model CPG2500 WIKA data sheet CT 25.02 Applications Factory calibration laboratories Calibration service companies and service
More informationSWISS MADE EXECUTIVE PRO. Precisa 360 EP
SWISS MADE EXECUTIVE PRO Precisa 360 EP Semi-micro Analytical Precision EXECUTIVE PRO Precisa 360 EP With the 360 EP series, Precisa is setting new standards in the demanding area of high-end laboratory
More informationPROVIDE SOLUTIONS END TO END
DENSE AUTOMATION (INDIA) PRIVATE LIMITED KALBURGI We Dense Automation Team has started to create milestones, and marked our presence in the beginning of 2018 and operate in the manufacturing of weather
More informationCI-150 Series. Airborne Particle Counters
CI-150 Series The CLiMET CI-150 series of full-featured airborne particle counters are the smallest, lightest and fastest counters with unsurpassed ease of use. It is the smallest and lightest 1.0 CFM
More information