1 Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications

2 IBM, pseries, AIX, xseries, AS/400, OS/400, and RS/6000 are registered trademarks and iseries, OpenPower, and i5/os are trademarks of International Business Machines Corp. Powerware and LanSafe are registered trademarks and X-Slot and ConnectUPS are trademarks of Eaton Power Quality Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation. Linux is a registered trademark of Linus Torvalds. Burndy is a registered trademark of Framatone Connectors International. ECopyright Eaton Corporation, Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced in any way without the express written approval of Eaton Corporation.

3 Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF ELECTRIC SHOCK - Indicates that a risk of electric shock is present and the associated warning should be observed. CAUTION: REFER TO OPERATOR S MANUAL - Refer to your operator s manual for additional information, such as important operating and maintenance instructions. This symbol indicates that you should not discard the UPS or the UPS batteries in the trash. This product contains sealed, lead-acid batteries and must be disposed of properly. For more information, contact your local recycling/reuse or hazardous waste center. This symbol indicates that you should not discard waste electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center.

4 This page intentionally left blank.

5 Table of Contents 1 Installation... 1 Parts List... 1 UPS Internal Battery Connection... 3 Setup and Installation... 4 Tools Required... 4 Rack-Mount Setup... 5 EBM Installation... 6 UPS Installation... 7 Remote Emergency Power-off Installation... 8 Power Connections and Startup... 9 Load Segments Operation Turning the UPS On Starting the UPS on Battery Turning the UPS Off Operating Modes Normal Mode Battery Mode Bypass Mode Standby Mode Configuration Mode Communication Single-Port Card Communication Options i5 Interface Overview iseries or AS/400 Interface Overview i5, iseries, or AS/400 and Serial Server Interface Overview Serial (TTY) Interface Overview p5 or pseries with Logical Partitions Interface Overview Service and Support EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C i

6 TABLE OF CONTENTS This page intentionally left blank. ii EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

7 Chapter 1 Installation Parts List Table 1. P33 Base Configuration Quantity IBM MN IBM FC IBM PN Eaton PN Description 1 P33 21P P33 UPS 3000 VA, 2700W 1 21P P33 Accessory Kit Table 2. P33 Application Matrix IBM MN IBM FC IBM PN Eaton PN Description 53P Left Rail (2U device) Quantity for p5/pseries Rack Worldwide Quantity for i5/iseriest Rack Worldwide P Right Rail (2U device) 1 each per P33 UPS 53P Rail Hardware Kit P Relay Interface Card and Cable (7.6m/25 ft) Kit J and/or 9188 PDU to UPS Power Cord (1.2m/4 ft) 1 1 per P33 UPS Varies Varies Varies Varies UPS Input Power Cord 1 per P33 UPS 1 Maximum: One FC 2934, 2936, or 2939 per P33 UPS. 2 For use with 7188 or 9188 PDU. EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 1

8 INSTALLATION Table 3. P33 Options Matrix IBM MN IBM FC IBM PN Eaton PN Description Quantity for p5/pseries Rack Worldwide Quantity for i5/iseries Rack Worldwide P ConnectUPSt-X Web/SNMP Min: 0, Max: 1 Card 2 Kit J Relay-Serial Card and Cable Kit Min: 0, Max: P Powerware Environmental Monitoring Probe (EMP) and CAT5Cable(1.8m/6ft)Kit P Extended Battery Module (EBM) Min: 0, Max: 1 Co-requisite: FC 2934 Min: 0, Max: 4 53P EBM Accessory Kit 1 per FC P Left Rail (2U Device) P RightRail (2U Device) 1 each per FC P Rail Hardware Kit N V Convenience PDU 3 (for modems, etc.) Min: 0, Max: 1 1 Maximum: One FC 2934, 2936, or 2939 per P33 UPS. 2 ConnectUPS-X Web/SNMP Card required if implementing Logical Partitions (LPARs) on p5 or pseries. 3 Powered from rack PDU receptacle (10A type). Table 4. P33 Accessory Kit (21P7229) Quantity Eaton PN Description Powerware 5125 Two-in-One UPS ( VA) User s Guide Powerware 5125 (9910-P33) Installation Guide for IBM Applications IEC 320-C13 to C14, 10A Equipment Power Cords (1.8m/6 ft) 1Bag Cord Retention Clips Software Suite CD UPS to Server Communication Cable (DB-9 to DB-9, 1.8m/6 ft) 2 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

9 INSTALLATION Table 5. EBM Accessory Kit (53P0865) Quantity Eaton PN Description Powerware 5125 (9910-P33) EBM Installation Guide for IBM Applications EBM Cable UPS Internal Battery Connection NOTE Check the battery recharge date on the shipping carton label. If the date has expired and the batteries were never recharged, do not use the UPS. Contact your service representative. To ensure proper battery operation before installing the UPS: 1. Verify that the UPS is off and unplugged. 2. Remove the packing material (see Figure 1). Figure 1. Removing Packing Material 3. Connect the internal battery connector (see Figure 2). NOTE A small amount of arcing may occur when connecting the batteries. This is normal and does not damage the unit or present any safety concern. EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 3

10 INSTALLATION Figure 2. Connecting the Internal Battery Connector 4. Install the UPS front cover (see Figure 3). Figure 3. Installing the Front Cover Setup and Installation The P33 UPS can be purchased separately or factory-installed in an IBM iseries or pseries rack. NOTE If the UPS is pre-installed in an IBM pseries (RS/6000) system, continue to EBM Installation on page 6 or UPS Installation on page 7. Tools Required To assemble the components, the following tools may be needed: S Medium flat-bladed screwdriver S #2 Phillips screwdriver 4 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

11 INSTALLATION Rack-Mount Setup The UPS can be installed in 19-inch racks and needs only 2U of valuable rack space. CAUTION The UPS and EBM are heavy. A minimum of two people are required to lift the cabinets into the rack. NOTE Fixed mounting rails are required for each UPS and EBM cabinet. If fixed rails are not already installed in your rack, contact your local IBM representative to order a rail kit(s). If you are installing the UPS in a non-ibm rack, contact your Powerware representative. To install the UPS in a rack: 1. Place the UPS on a flat, stable surface with the front of the UPS facing toward you. 2. Attach the supplied mounting handles to the mounting brackets and secure with the supplied screws (see Figure 4). 3. If installing optional EBMs, repeat Steps 1 and 2 for each cabinet. Mounting Handle Figure 4. Installing the Mounting Handles Mounting Bracket NOTE The UPS and EBMs MUST be installed at the bottom of the rack. If placed in a rack with existing equipment, the rack must be reconfigured to allow the UPS installation at the bottom of the rack. NOTE The EBMs must be installed below the UPS as shown in Figure Slide the UPS and any optional EBMs into the rack. 5. Secure the units to the rack according to the rail kit instructions. EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 5

12 INSTALLATION UPS Optional EBMs Figure 5. Rack-Mount UPS with EBMs EBM Installation NOTE Up to four EBMs may be connected to the UPS. If there are two UPSs in a rack, up to two EBMs may be connected to each UPS. To install an optional EBM(s): 1. Verify that all battery circuit breakers are in the OFF (O) position (see Figure 6). 2. Plug the EBM cable(s) into the battery connectors as shown in Figure 6. Up to four EBMs may be connected to the UPS. 3. Continue to the following section, UPS Installation. Communication Port Input Connector Power Cord Circuit Breakers UPS Battery Connector REPO Port Output Receptacles EBM Battery Connectors EBM Cable ON OFF Battery Circuit Breaker 6 Figure 6. Typical EBM Installation EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

13 INSTALLATION UPS Installation NOTE Do not make unauthorized changes to the UPS; otherwise, damage may occur to your equipment and void your warranty. To install the UPS: 1. If you are installing power management software, connect your computer to the UPS communication port or optional X-Slott card (see Table 10 on page 26). For the communication port, use only the serial cable supplied in the P33 accessory kit. 2. If your rack has conductors for grounding or bonding of ungrounded metal parts, connect the ground cable (not included) to the ground bonding screw. Communication Port 16A, IEC 320-C20 Input Connector IEC 320-C13 Receptacles X-Slot Communication Bay Ground Bonding Screw Circuit Breakers REPO Port Battery Connector IEC 320-C19 Receptacle Figure 7. UPS Rear View 3. If an emergency power-off (disconnect) switch is required by local codes, see the following section, Remote Emergency Power-off Installation to install the REPO switch before powering on the UPS. 4. Continue to Power Connections and Startup on page 9. EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 7

14 INSTALLATION Remote Emergency Power-off Installation The P33 includes a REPO port that allows power to be switched off at the UPS output receptacles from a customer-supplied switch in a remote location. The REPO feature shuts down the protected equipment immediately and does not follow the orderly shutdown procedure initiated by any power management software. Any devices that are operating on battery power are also shut down immediately. When the REPO switch is reset, the equipment will not return to battery power until the UPS is manually restarted. If the Off button is pressed after the REPO is activated, the UPS remains in Standby mode when restarted until the On button is pressed. WARNING The REPO circuit is an IEC safety extra low voltage (SELV) circuit. This circuit must be separated from any hazardous voltage circuits by reinforced insulation. CAUTION To ensure the UPS stops supplying power to the load during any mode of operation, the input power must be disconnected from the UPS when the emergency power-off function is activated. NOTE The REPO function activates when the REPO contacts close. NOTE If the REPO function is not needed, the REPO connector must remain installed in the REPO port on the UPS rear panel. NOTE For Europe, the emergency switch requirements are detailed in Harmonized document HD S1, Electrical Installation of the Buildings, Part 4: Protection for Safety, Chapter 46: Isolation and Switching. To install the REPO switch: 1. Verify that the UPS is off and unplugged. 2. Remove the REPO connector from the REPO port on the UPS rear panel. 8 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

15 INSTALLATION 3. Connect isolated, normally-open, dry contacts (rated to handle 60 Vdc maximum, 30 Vac RMS maximum, and 20 ma maximum) acrosstherepodevicetopin1andpin2(seefigure8). Use stranded, non-shielded wiring, size 0.75 mm mm 2 (18 20 AWG). NOTE A separate contact must simultaneously cause UPS input AC power to be removed. 4. Reconnect the REPO connector to the REPO port. Pin 1 Pin 2 Figure 8. REPO Connector 5. Verify that the externally-connected REPO switch is not activated to enable power to the UPS output receptacles. 6. Plug in the UPS and start the UPS by pressing the On button. 7. Activate the external REPO switch to test the REPO function. 8. De-activate the external REPO switch and restart the UPS. Power Connections and Startup The device power cord connection(s) determines if the setup can provide dual-redundant power to the protected device(s). See Figure 9 for a non-redundant powered device; Figure 10 shows a dual-redundant powered device. Legend (Figure 9 and Figure 10) 1 UPS to utility (mains) power cord 2 PDU to UPS power cord 3 PDU to utility (mains) power cord EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 9

16 INSTALLATION PDU UPS Mains 1 2 Figure 9. Connecting One PDU (Non-Redundant) to UPS PDU PDU UPS TVSS Protected or Second UPS Mains Mains Figure 10. Connecting Two PDUs (Dual-Redundant) to UPS 1. If you are installing a UPS and non-redundant power to the device(s) is desired, plug the PDU power cord into the UPS output receptacle (see Figure 9) using the supplied power cord. If you are installing a UPS and dual-redundant power to the device(s) is desired, two PDUs are required. Plug the first PDU power cord into the UPS output receptacle (see Figure 10) using the supplied power cord. Then plug the second (redundant) PDU power cord into a non-ups protected output receptacle (mains) or into a second UPS. NOTE The redundant power source must be protected with Transient Voltage Surge Suppression (TVSS). 2. Insert the supplied cord retention clips by each output receptacle that will be used (see Figure 11). 10 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

17 INSTALLATION Figure 11. Attaching the Cord Retention Clips 3. Plug the equipment to be protected into the appropriate UPS output receptacles (see page 15 for more information on load segments). Table 6. Plug Types Supported IBM Plug Type Description Quantity Supported IEC 320-C14 9 IEC 320-C20 1 NOTE DO NOT protect laser printers with the UPS because of the exceptionally high power requirements of the heating elements. NOTE To prevent an overload alarm, verify that the total equipment ratings do not exceed the UPS capacity. 4. Bend and twist the cord retention clips around the equipment power cords to secure the cord connections (see Figure 11). 5. If you installed an optional EBM(s), remove the breaker tie from all battery circuit breakers. Switch all battery circuit breakers to the ON ( ) position. 6. Plug the detachable UPS power cord into the input connector on the UPS rear panel. EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 11

18 INSTALLATION 7. Plug the UPS power cord into a power outlet. All front panel indicators flash briefly and then only the indicator flashes, indicating the UPS is in Standby mode with the equipment offline. If the alarm beeps or a UPS alarm indicator stays on, refer to Troubleshooting in the Powerware 5125 Two-in-One UPS ( VA) User s Guide. 8. Press and hold the On button until you hear the UPS beep (approximately one second). The indicator illuminates solid and the load level indicators display the percentage of load being applied to the UPS. The UPS is now in Normal mode and supplying power to your equipment. NOTE The batteries charge to 90% capacity in approximately 3 hours. However, it is recommended that the batteries charge for 24 hours after installation or long-term storage. NOTE If you installed power management software and optional EBMs, ensure maximum battery runtime by using the ERM configuration tool on the Software Suite CD. NOTE If more than two EBMs are installed, an external battery charger is recommended for faster recharge times. If you have questions about implementing non- or dual-redundant power, the following options are available: S or S Submit your question to Ask the Expert at S Submit your question to our FAQ database at S Contact the IBM office or Business Partner servicing your account 12 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

19 INSTALLATION Table 7. Typical Power Connections Item Description 1 IEC 320-C19 2 IEC 320-C20 3 Burndy UTG Receptacle 4 Burndy UTG Plug 5 Country-Specific UPS power (mains) cord Amperage IBM FC IBM PN Plug Type Supplier Description 30A J Eaton IEC 320-C19 to NEMA L6-30P, 2.4m/8 ft with input breaker 32A J Eaton IEC 320-C19 to IEC-309 (P+N+G) 32A, 4.3m/14 ft with input breaker 20A F IBM IEC 320-C19 to NEMA L6-20P, 4.3m/14 ft 20A H IBM IEC 320-C19 to NEMA L6-20P, 4.3m/14 ft 16A F IBM IEC 320-C19 to CEE 7 VII, 4.3m/14 ft 16A F IBM IEC 320-C19 to SABS 164 BS 546, 4.3m/14 ft 16A F IBM IEC 320-C19 to CEI 23-16, 4.3m/14 ft 16A F IBM IEC 320-C19 to IEC-309 (P+N+G) 16A, 4.3m/14 ft 16A F IBM IEC 320-C19 to SII , 4.3m/14 ft 16A F IBM IEC 320-C19 to SAA-AS 3112, 4.3m/14 ft 16A L IBM IEC 320-C19 to IEC A5, 4.3m/14 ft 6 PDU to UPS power cord IBM FC IBM PN Plug Type Supplier Description J2590 Eaton Burndy UTG to IEC 320-C20 PDU Power Cord, 1.8m/6 ft 7 PDU to utility (mains) power cord* IBM FC IBM PN Plug Type Supplier Description R IBM Burndy to NEMA L6-30P, 4.3m/14 ft R IBM Burndy to RS 3750, 4.3m/14 ft R IBM Burndy to IEC-309 (P+N+G) 32A, 4.3m/14 ft R2558 PDL IBM Burndy to PDL, 4.3m/14 ft R2559 KP IBM Burndy to KP, 4.3m/14 ft 8 IEC 320-C13 * Other power cords are supported by the PDU. Power cords shown are similar in voltage and amperage to the UPS. EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 13

20 INSTALLATION NOTE P33 supports: PDU types 5160, 7176, or 9176 with FC 9851; PDU types 5161, 7177, or 9177 with FC NOTE P33 does not support iseries PDU 5162, IEC-309 (3P+N+G) 16A. NOTE P33 has a maximum output capacity of 2700 watts even though IBM PDU 7188 or 9188 can support higher power output. Plan accordingly. Device 4 PDU IBM iseries or pseries 7188 or Eaton (6) Varies (5) P W UPS 8 8 Mains Varies Figure 12. P33 with Non-Redundant Power Device 4 PDU IBM iseries or pseries 7188 or Eaton (6) Varies (5) 4 3 IBM (7) PDU IBM iseries or pseries 7188 or P W UPS 8 8 Mains Varies Mains Varies Figure 13. P33 with Dual-Redundant Power 14 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

21 INSTALLATION Load Segments Load segments are sets of receptacles that can be controlled by power management software, providing an orderly shutdown and startup of your equipment. For example, during a power outage, you can keep key pieces of equipment running while you turn off other equipment. This feature allows you to save battery power. See your power management software manual for details. NOTE If power management software is not used, the individual load segments cannot be controlled. Each UPS has three load segments as shown in Figure 14. Load Segment 2 Load Segment 1 Load Segment 3 Figure 14. UPS Load Segments EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 15

22 INSTALLATION This page intentionally left blank. 16 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

23 Chapter 2 Operation This section describes: S Turning the UPS on and off S Starting the UPS on battery S Operating modes Turning the UPS On Starting the UPS on Battery After the UPS is connected to a power outlet, it enters Standby mode. To turn on the UPS, press and hold the On button until you hear the UPS beep (approximately one second). The indicator illuminates solid and the load level indicators display the percentage of load being appliedtotheups. NOTE Before using this feature, the UPS must have been powered by utility power at least once. To turn on the UPS without using utility power, press and hold the On button for at least four seconds. The UPS supplies power to your equipment and goes into Battery mode. Turning the UPS Off To turn off the UPS: 1. Prepare your equipment for shutdown. 2. Press and hold the Off button until the long beep ceases (approximately five seconds). The indicator begins to flash and the UPS switches to Standby mode (if utility power is available) and removes power from your equipment. 3. Unplug the UPS. If you do not unplug the UPS, it remains in Standby mode. EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 17

24 OPERATION Operating Modes P33 s front panel indicates the UPS status through the UPS indicators. Figure 15 shows the UPS front panel indicators and controls. Normal Mode Indicator (Solid Green) Standby Mode Indicator (Flashing Green) Bypass Mode Indicator (Solid Red) Indicator Legend Unlit Green Red Flashing On Button Off Button Alarm Reset Button Battery Mode Indicator Load Level Indicators Figure 15. UPS Front Panel Normal Mode During Normal mode, the indicator illuminates and the front panel displays the percentage of UPS load capacity being used by the protected equipment (see Figure 16). The UPS monitors and charges the batteries as needed and provides power protection to your equipment. >100% % 51 75% 26 50% 0 25% Figure 16. Load Level Indicators When all of the load level indicators and the indicator are illuminated, power requirements exceed UPS capacity; refer to Troubleshooting in the Powerware 5125 Two-in-One UPS ( VA) User s Guide for more information. 18 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

25 OPERATION Battery Mode When the UPS is operating during a power outage, the alarm beeps once every five seconds and the indicator illuminates. When the utility power returns, the UPS switches to Normal mode operation while the battery recharges. If battery capacity becomes low while in Battery mode, the indicator starts flashing and the alarm becomes continuous. Immediately complete and save your work to prevent data loss and similar difficulties. When utility power is restored after the UPS shuts down, the UPS automatically restarts. The indicator flashes until the battery has recharged to an acceptable level. Bypass Mode In the event of a UPS overload or internal failure, the UPS transfers your equipment to utility power. Battery mode is not available; however, the utility power continues to be passively filtered by the UPS. The alarm sounds and the indicator illuminates red. The UPS switches to Bypass mode when: S The UPS has an overtemperature condition. S The UPS has an overload condition of 103 to 110% for 30 seconds. S The UPS detects a fault in the battery or UPS electronics. Standby Mode When the UPS is turned off and remains plugged into a power outlet, the UPS is in Standby mode. The indicator flashes and the load level indicators are off, indicating that power is not available to your equipment. The battery recharges when necessary. NOTE For V models, the output receptacles may remain electrically live (up to V). Unplug the UPS to ensure power is not available to the output receptacles. EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 19

26 OPERATION Configuration Mode When the UPS is in Configuration mode, the front panel indicators represent the configuration options. Use the control buttons (On button, Off button, and button) to modify the UPS configuration. Figure 17 shows the indicators and Table 8 explains the corresponding options. 1. Press and hold the On button and the button simultaneously for one beep (approximately five seconds). The UPS switches to Configuration mode. The indicators flash briefly and then display the enabled options. 2. Press the On button to scroll through the options. Each time you press the button, the UPS beeps. The indicator for the selected option indicates the current setting; flashing represents disabled options (see Figure 17 and Table 8). Scrolling past the last indicator returns to the first configuration option. If you press the On button and nothing happens, the UPS is still in Operation mode. Repeat Step 1 for one beep ONLY to enter Configuration mode, and then perform Step Press the Off button button ONCE to select the Voltage option or to toggle the Site Wiring Fault Alarm on or off. NOTE The UPS exits Configuration mode automatically after two minutes. 4. Press the button to confirm the selection and exit Configuration mode. If you do not press the button, the UPS defaults to the original settings. 20 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

27 OPERATION 1 2 Press and hold the On and Alarm Reset Press the On button to buttons simultaneously to enter scroll to the next option. Configuration mode. On Button Off Button Alarm Reset Button Configuration Mode Indicators 3 Press the Off button ONCE to select the option. Figure 17. Using Configuration Mode 4 Press the Alarm Reset button to save the setting and exit Configuration mode. EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 21

28 OPERATION Table 8. Configuration Mode Indicators and Options Configuration Mode Indicators Option Indicator Status Explanation 100/ V Nominal Input Voltage On Selecting this option changes the nominal input voltage on low voltage models to 100V and to V for high voltage models. Flashing 100/ V is disabled; one of the other input voltage options is selected. 110/220V Nominal Input Voltage On Selecting this option changes the nominal input voltage on low voltage models to 110V and to 220V for high voltage models. Flashing 110/220V is disabled; one of the other input voltage options is selected. 120/230V Nominal Input Voltage On Selecting this option changes the nominal input voltage on low voltage models to 120V and to 230V for high voltage models. Flashing 120/230V is disabled; one of the other input voltage options is selected. 127/240V Nominal Input Voltage On* Selecting this option changes the nominal input voltage on low voltage models to 127V and to 240V for high voltage models. *Default for P33. Flashing 127/240V is disabled; one of the other input voltage options is selected. Site Wiring Fault Alarm On Alarm sounds when the polarity of the outlet is reversed or the ground connection is missing; have a qualified electrician repair the outlet wiring. Flashing* Alarm DOES NOT sound when the polarity of the outlet is reversed or the ground connection is missing. *Site Wiring Fault is not available for 100, 200, or 208V models. 22 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

29 Chapter 3 Communication This section includes S Single-Port Card information S Communication options Single-Port Card The P33 is factory-installed with a Single-Port Card, enabling connection to a PC for power management control. To establish communication between the UPS and a computer, connect your computer to the UPS communication port using the supplied communication cable. When the communication cable is installed, power management software can exchange data with the UPS. The software polls the UPS for detailed information on the status of the power environment. If a power emergency occurs, the software initiates the saving of all data and an orderly shutdown of the equipment. The cable pins are identified in Figure 18 and the pin functions are described in Table Figure 18. Communication Port EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 23

30 COMMUNICATION Table 9. Communication Port Pin Assignment Pin Number SignalName Function Direction from the UPS 1 Low Batt Low Battery relay contact Out 2 TxD Transmit to external device Out 3 RxD Receive from external device In 4 DTR PnP (Plug and Play) from external device (tied to Pin 6) In 5 GND Signal common (tied to chassis) 6 DSR To external device (tied to Pin 4) Out 7 RTS PnP from external device (default) or On Bypass relay contact (jumper-selectable) In / Out 8 AC Fail AC Fail relay contact Out 9 Power Source +V (8 to 24 volts DC power) Out The On-Bypass Relay Contact. You can enable the On-Bypass relay using the jumper on the Single-Port Card. The jumper default is disabled. To enable the On-Bypass relay: 1. Remove the Single-Port Card on the UPS rear panel. Retain the screws (see Figure 19). Figure 19. Removing the Single-Port Card 2. Move the J3 jumper to the AS/400 position to enable the On-Bypass relay as shown in Figure EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

31 COMMUNICATION On-Bypass Disabled On-Bypass Enabled NORM AS/400 On-Bypass Relay Jumper (J3) Figure 20. On-Bypass Relay Jumper 3. To prevent electrostatic discharge (ESD), place one hand on a metal surface such as the UPS rear panel. Align the Single-Port Card with the slot guides and slide the card into the slot until it is firmly seated. 4. Secure the Single-Port Card with the screws removed in Step 1. EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 25

32 COMMUNICATION Communication Options Table 10. Communication Options If you want the UPS to communicate with your computer, use Table 10 to determine which communication option is correct for your application. Application Software Suite CD and Serial Cable ConnectUPS-X Web/SNMP Card Kit (FC 2934) Relay Interface Card and Cable Kit (FC 2936) Relay-Serial Card and Cable Kit (FC 2939) IBM i5/iseries Server X IBM i5/iseries Server and Serial Server (Microsoft Windows, Linux,AIX,or other operating systems) IBM p5/pseries Server, OpenPowert,orxSeries Server with Single Serial (TTY) Connection IBM p5/pseries Server, OpenPower, or xseries Server with LPARs and/or Network (WebServer) Connection (UPS as a node) X X X Follow the installation instructions with the Software Suite CD or the applicable card kit. This section shows the communication option overviews. For additional information and a current listing of supported operating systems, go to 26 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

33 COMMUNICATION i5 Interface Overview To connect the UPS to an i5 you need: S An Eaton-supplied Relay Interface Card and AS/400 interface cable (labeled ), located in the FC 2936 carton labeled Cable Kit for IBM iseries S An IBM-supplied UPS interface cable (labeled 1827), included with the server Follow the instructions included with the Relay Interface Card and Cable Kit to install the card and set UPS monitoring functions in i5/ost. Installation may include removal of an existing X-Slot card from the UPS. Connect the cables as shown in Figure 21. IBM i5 Server P1-T1 UPS Port UPS Interface Cable (labeled 1827) AS/400 Interface Cable (labeled ) Relay Interface Card Communication Port UPS Figure 21. i5 Interface EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 27

34 COMMUNICATION iseries or AS/400 Interface Overview To connect the UPS to an iseries or AS/400 you need: S An Eaton-supplied Relay Interface Card and AS/400 interface cable (labeled ), located in the FC 2936 carton labeled Cable Kit for IBM iseries Follow the instructions included with the Relay Interface Card and Cable Kit to install the card and set UPS monitoring functions in OS/400. Installation may include removal of an existing X-Slot card from the UPS. Connect the cable as shown in Figure 22. IBM iseries Server J14 UPS Port (location may vary by model) AS/400 Interface Cable (labeled ) Communication Port UPS Relay Interface Card Figure 22. iseries or AS/400 Interface 28 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

35 COMMUNICATION i5, iseries, or AS/400 and Serial Server Interface Overview To connect the UPS to an i5, iseries, or AS/400 and a serial server you need: S An Eaton-supplied Relay-Serial Card, an AS/400 interface cable (labeled ), and a serial interface cable (labeled ), located in the FC 2939 carton labeled Cable Kit for IBM iseries and Windows or AIX/Linux Servers S For the i5 only: An IBM-supplied UPS interface cable (labeled 1827), included with the server S For the serial server only: Powerware LanSafe Power Management Software from the Software Suite CD, located in the P33 accessory kit Follow the instructions included with the Relay-Serial Card and Cable Kit to install the card and set UPS monitoring functions in i5/os and serial (TTY) server. Installation may include removal of an existing X-Slot card from the UPS. Follow the software installation instructions contained on the Software Suite CD to install the Powerware LanSafe software. If you have an i5, connect the cables as shown in Figure 23. Otherwise, see Figure 24 to connect the cables. Serial (TTY) Server IBM i5 Server P1-T1 UPS Port UPS Interface Cable (labeled 1827) Serial Interface Cable (labeled ) AS/400 Interface Cable (labeled ) Relay-Serial Card Communication Port UPS Figure 23. i5 and Serial Server Interface EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 29

36 COMMUNICATION Serial (TTY) Server Serial Interface Cable (labeled ) IBM iseries Server J14 UPS Port (location may vary by model) Communication Port UPS AS/400 Interface Cable (labeled ) Relay-Serial Card Figure 24. iseries or AS/400 and Serial Server Interface 30 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

37 COMMUNICATION Serial (TTY) Interface Overview To serially (TTY) connect the UPS to a p5, pseries, RS/6000, OpenPower or other system you need: S An Eaton-supplied serial interface cable (labeled ), located in the P33 accessory kit S Powerware LanSafe Power Management Software from the Software Suite CD, located in the P33 accessory kit For p5 installations, you also need: S An IBM-supplied 2-port Asynchronous EIA adapter (FC 5723) installed on a p5 server (the pseries does not require an EIA adapter) S An IBM-supplied maintenance package for AIX 5.2L V5.2 (APAR IY66260); or the maintenance package for AIX 5.3L V5.3 (APAR IY62267) Follow the software installation instructions contained on the Software Suite CD to install the Powerware LanSafe software. Connect the serial cable as shown in Figure 25. IBM p5 Server Serial Interface Cable (labeled or ) 2-Port Asynchronous EIA Adapter (FC 5723) Communication Port UPS Figure 25. Serial (TTY) Interface EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 31

38 COMMUNICATION p5 or pseries with Logical Partitions Interface Overview To connect the UPS to a p5 or pseries with LPARs you need: S An Eaton-supplied ConnectUPS-X Web/SNMP Card, located in the FC 2934 carton labeled ConnectUPS-X Web/SNMP Card Kit S NetWatch software from the Software Suite CD, located in the P33 accessory kit S A customer-supplied Ethernet cable S An available Ethernet port on the server Follow the instructions included with the ConnectUPS-X Web/SNMP Card Kit to install the card and set UPS monitoring functions. Installation may include removal of an existing X-Slot card from the UPS. Follow the software installation instructions contained on the Software Suite CD to install the NetWatch software onto each LPAR. Connect the Ethernet cable as shown in Figure 26. IBM p5 Server Ethernet Cable (customer-supplied) The server must have an available Ethernet port. ConnectUPS-X Web/SNMP Card Ethernet Connectors UPS Figure 26. p5 or pseries with LPARs Interface 32 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

39 Chapter 4 Service and Support In the United States and Canada, call IBMSERV ( ). In Europe, the Middle East, and Africa (EMEA); Latin America; or Asia-Pacific, call the IBM office that services your account. Please have your serial, model, and part number ready when you call (see Figure 27). For additional information, see the appropriate user s guide for the UPS or Extended Battery Module (EBM). (S/N Bar Code 39) Front Panel Label S991010L3AAA Serial Number Model Number Part Number Serial Number Rear Panel Label IBM/UPS Type-Model/Feature: 9910-P33 (P) IBM P/N: 21P7219 (IBM Part Number Bar Code 39) (Data: P21P7219) (S) Serial Number: L3AAA (Serial Number Bar Code 39) (Data: S991010L3AAA) (2P) EC: xxxxxx (EC Number Bar Code 39) (Data: xxxxxxxx) Assembled in Mexico Date of MFG: YYYYMMDD Figure 27. Example of IBM Serial Number Labels Comments We welcome your comments about this manual. Please send your questions or suggestions for improvements to ibm.ups@powerware.com. EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C 33

40 SERVICE AND SUPPORT This page intentionally left blank. 34 EATON Powerware 5125 (9910-P33) UPS Installation Guide for IBM Applications S Rev C

41 Requesting a Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonized standards and EU directives: S Harmonized Standards: EN and EN ; IEC Third Edition S EU Directives: 73/23/EEC, Council Directive on equipment designed for use within certain voltage limits 93/68/EEC, Amending Directive 73/23/EEC 89/336/EEC, Council Directive relating to electromagnetic compatibility 92/31/EEC, Amending Directive 89/336/EEC relating to EMC The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC Declaration of Conformity, contact: Eaton Power Quality Oy Koskelontie 13 FIN Espoo Finland Phone: Fax: FCC Part 15 Class A EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. ICES-003 This Class A Interference Causing Equipment meets all requirements of the Canadian Interference Causing Equipment Regulations ICES-003. Cet appareil numérique de la classe A respecte toutes les exigences du Reglement sur le matériel brouilleur du Canada. EN Some configurations are classified under EN as Class-A UPS for Unrestricted Sales Distribution. For these configurations, the following applies: WARNING This is a Class A-UPS Product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take additional measures. VCCI Notice

Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications

Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF

More information

Powerware 9125 (9910-E64) UPS Installation Guide for IBM Applications

Powerware 9125 (9910-E64) UPS Installation Guide for IBM Applications Powerware 9125 (9910-E64) UPS Installation Guide for IBM Applications Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF

More information

Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications

Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF

More information

Powerware 5115 (9910-P13 and P14) Communication Options for IBM Applications

Powerware 5115 (9910-P13 and P14) Communication Options for IBM Applications Powerware 5115 (9910-P13 and P14) Communication Options for IBM Applications Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information:

More information

powerware 5105 User s Guide VA

powerware 5105 User s Guide VA powerware 5105 User s Guide 450-1500 VA www.powerware.com Requesting a Declaration of Conformity The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the

More information

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide For use with 9PX 5000/6000/8000/11000 VA UPS Models FCC Part 15 Class A EMC Statements

More information

Powerware 3105 UPS User s manual

Powerware 3105 UPS User s manual Powerware 3105 UPS 2005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care

More information

Powerware 3105 UPS User s manual

Powerware 3105 UPS User s manual Powerware 3105 UPS 2005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care

More information

3M Wrist Strap and Ground Monitor 773. User s Guide

3M Wrist Strap and Ground Monitor 773. User s Guide 3M Wrist Strap and Ground Monitor 773 User s Guide Table of Contents Section Page Safety Information... 2 1 Description... 4 Overview... 4 Performance... 4 2 Installation... 5 Supplied Parts... 5 Wire

More information

EATON 9130 UPS VA User's guide

EATON 9130 UPS VA User's guide ENGLISH EATON 9130 UPS 5000-6000 VA User's guide Copyright 2010 EATON All rights reserved. Service and support: Call your local service representative Class A EMC Statements Directives references This

More information

9910-UPS Rack Chart Updated Oct 05

9910-UPS Rack Chart Updated Oct 05 All devices and UPS in One rack? es One to Two* or Two or Four** 9188-7188 PDUs? es es If LPAR s or Web/SNMP connectivity (interface) required, select FC 934 If no LPAR s ensure p5 has #573 for serial

More information

Multi-Server Module. User s Guide.

Multi-Server Module. User s Guide. Multi-Server Module User s Guide www.powerware.com Requesting a Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonized standards and EU directives: : Harmonized

More information

Configuration Questions:

Configuration Questions: Configuration Questions: 1 What equipment will be protected? Calculate using Table 1 What do I want the UPS to do? Shutdown server(s) interface? Provide extended battery (autonomy) runtime? 3 Where do

More information

Powerware 9910-P11 and 9910-P16

Powerware 9910-P11 and 9910-P16 Powerware 9910-P11 and 9910-P16 High Performance High Reliability & Availability Flexible & Configurable Advanced Communications 2002 Eaton Corporation. All rights reserved. P11 and P16 Features Fourth-Generation

More information

Powerware P64

Powerware P64 Powerware 91259 9910 - P64 High Performance High Reliability & Availability Flexible & Configurable Advanced Communications p64pres.ppt rev 4.16.04 1 P64 Features Double-conversion online High-power density

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

UPS USER S GUIDE kva, 50 and 60 Hz.

UPS USER S GUIDE kva, 50 and 60 Hz. 9170 + 3 18 kva, 50 and 60 Hz UPS USER S GUIDE www.powerware.com Requesting a Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonized standards and EU directives:

More information

HP UPS R5500 User Guide

HP UPS R5500 User Guide HP UPS R5500 User Guide Part Number 351643-004A September 2007 (Fourth Edition) Copyright 2003, 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without

More information

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement First Edition: December 2005 Last Revision: December 2005 Document # 103518-00 Legal Notices Disclaimer Information

More information

AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide

AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide AT-PWR01 AT-PWR02 AT-FAN01 Removable Power Supply and Fan Removable Power Supply and Fan Installation Guide for AT-8900,

More information

hp uninterruptible power system r12000 xr models installation instructions

hp uninterruptible power system r12000 xr models installation instructions hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer

More information

UPS R3000 XR Maintenance and Service Guide

UPS R3000 XR Maintenance and Service Guide UPS R3000 XR Maintenance and Service Guide First Edition (September 2000) Part Number 221891-001 Spare Part Number 223932-001 Compaq Computer Corporation Notice 2000 Compaq Computer Corporation COMPAQ,

More information

4170 POS System Installation Guide

4170 POS System Installation Guide 4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document

More information

Configuration Questions:

Configuration Questions: Configuration Questions: 1 What equipment will be protected? Calculate using Table 1 What do I want the UPS to do? Shutdown server(s) interface? Provide extended battery (autonomy) runtime? 3 Where do

More information

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems IBM United States Announcement 108-068, dated January 29, 2008 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Key prerequisites...2 Description...2 Publications...

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

2 Mesa Ethernet Dock User s Manual

2 Mesa Ethernet Dock User s Manual owner s manual Mesa Ethernet Dock The Mesa Ethernet Dock is an optional accessory that provides an ethernet port for networking, power input jack, USB client port, and a mounting station for the Mesa Rugged

More information

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see

More information

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A Installation Guide Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit Issue: 052209 PN: 883884-11L Rev. A ii Copyright Notice 2009, Wyse Technology Inc. All rights reserved. This manual and the software

More information

Powerware Software Connectivity Service. > Powerware Software Suite ensures data integrity; free updates on

Powerware Software Connectivity Service. > Powerware Software Suite ensures data integrity; free updates on Powerware 9120 Features True double conversion online technology give you protection from all nine power problems Simple installation and operation Intuitive LCD screen provides realtime updates of UPS

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis The Transition Networks CPSMC0200-2x0 series dual-slot PointSystem chassis is designed for installation of one or two selectable Transition Networks

More information

9910-UPS Rack Chart (IEC309 16A) power cord

9910-UPS Rack Chart (IEC309 16A) power cord All devices and UPS in One rack? Zero to Two* or Two or Four** 7188 PDUs? Yes No No One 5161 PDU? (Figure 2) 9910-UPS Chart No Go to Tower UPS Charts or Contact Eaton (Powerware) +44 add number here i5

More information

CSM200 Expansion Tray

CSM200 Expansion Tray CSM200 Expansion Tray Initial Setup Guide for SANtricity users or VTL environments EC1718-1-E3, Third Edition Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

Perle MCR200 Installation Guide

Perle MCR200 Installation Guide Perle MCR200 Installation Guide P/N 5500322-10 Introduction The Perle MCR200 Chassis is a 2 slot chassis able to accommodate up to 2 Perle Media Converter modules or 1 Media Converter Module and an MCR-MGT

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

SySTIUM TM TECHNOLOGIES Model 215

SySTIUM TM TECHNOLOGIES Model 215 SySTIUM TM TECHNOLOGIES Model 215 MotherBoard Ready SM System ASSEMBLY GUIDE SySTIUM TM TECHNOLOGIES MOTHERBOARD READ Y SM SYSTEM MODEL 215 Radio Frequency Interference Notice (USA) This equipment has

More information

User Manual Back-UPS BE650MC

User Manual Back-UPS BE650MC User Manual Back-UPS BE650MC Inventory Back-UPS ES 650 bu075b This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive

More information

EATON 5S 850/1200/1600

EATON 5S 850/1200/1600 www.eaton.com EATON 5S 850/1200/1600 Installation and user manual Packaging EATON 5S 1 2 3 5 Caution! l Before installing the Eaton 5S, read the booklet 3 containing the safety instructions to be respected.

More information

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus Powerware 9120 Uninterruptible Power System Product Focus Product Snapshot Power Rating: 700-3000VA Voltage: 120 and 230 Vac Frequency: 50/60 Hz (auto-sensing) Configuration: tower Features True double-conversion

More information

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. AREA CODE CHANGE Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. For any Paradyne telephone number that appears in this manual with an 813 area code,

More information

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i Assembly Guide Model 133i Radio Frequency Interference Notice (USA) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules,

More information

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems IBM Latin America Hardware Announcement LG10-0100, dated May 18, 2010 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Table of contents 1 Overview 2 Product

More information

Powerware 9120 UPS. Product Snapshot. Features

Powerware 9120 UPS. Product Snapshot. Features Powerware 9120 UPS Features True double conversion online technology give you protection from all nine power problems Simple installation and operation Intuitive LCD screen provides realtime updates of

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

IFS MCR-R15 Media Converter Rack User Manual

IFS MCR-R15 Media Converter Rack User Manual IFS MCR-R15 Media Converter Rack User Manual P/N 1076518 REV A ISS 08FEB12 Copyright Trademarks and patents Manufacturer Version Certification FCC compliance ACMA compliance European Union directives 2012

More information

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems IBM United States Hardware Announcement 110-077, dated May 18, 2010 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Table of contents 1 Overview 2 Product number

More information

HP R/T3000 G2 UPS User Guide

HP R/T3000 G2 UPS User Guide HP R/T3000 G2 UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP R/T3000 G2 UPS. This document is for the person who installs and maintains

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

IFS NS3550-8T-2S Quick Installation Guide

IFS NS3550-8T-2S Quick Installation Guide IFS NS3550-8T-2S Quick Installation Guide P/N 1072772 REV A ISS 24JUN14 Copyright Trademarks and patents Intended use Manufacturer Certification FCC compliance ACMA compliance Canada European Union directives

More information

Auto-Transfer Rack Power Distribution Unit

Auto-Transfer Rack Power Distribution Unit Auto-Transfer Rack Power Distribution Unit geistglobal.com 2 Auto-Transfer Rack Power Distribution Unit Table of Contents Part I Specifications 3 1 Overview... 3 2 Environmental... 3 Tem perature... 3

More information

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference. INSTRUCTION MANUAL DISTRIBUTION UNIT Please read this manual thoroughly before use, and keep it handy for future reference. ISSUE 1 May 2006 LIMITATION OF LIABILITY THE INFORMATION IN THIS PUBLICATION

More information

EZ-LP Quick Start Guide

EZ-LP Quick Start Guide EZ-LP Quick Start Guide Keep Your Code. Choose Your Printer. POWER READY CognitiveTPG Headquarters 25 Tri-State International, Suite 200, Lincolnshire, IL 60069 Toll Free: 800-732-8950 Phone: 847-383-7900

More information

eserver Integration

eserver Integration 9125 - eserver TOPICS Preparation Startup Optional Features Help/Resources 9125Install - iseries Dec, 2000 Page 1 Step 1 - Remove UPS equipment from Cartons UPS must be placed near the installation site

More information

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments Powerware 9140 Uninterruptible Power System Product Focus Superior de-centralized power protection for medium- and high-density rack environments Product Snapshot Features Protects mission-critical rackmount

More information

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments Powerware 9140 Uninterruptible Power System Product Focus Superior de-centralized power protection for medium- and high-density rack environments Product Snapshot Power Rating: Nominal Input Voltage: Nominal

More information

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions

More information

EATON Transformer Module

EATON Transformer Module www.eaton.com EATON Module Quick Start Standard Features When used with standard system, EATON Module provides isolated and Step-down 0/08/0 V AC outputs. Multiple Output receptacles: 0/08/0 V AC. 86-86000-0

More information

IFS NS3552-8P-2S and NS3550-2T-8S Quick Installation Guide

IFS NS3552-8P-2S and NS3550-2T-8S Quick Installation Guide IFS NS3552-8P-2S and NS3550-2T-8S Quick Installation Guide P/N 1072679 REV A ISS 19DEC13 Copyright Trademarks and patents Manufacturer 2013 United Technologies Corporation Interlogix is part of UTC Climate

More information

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP INTRODUCTION The Adaptec SCSI Card 29320LP enables you to connect up to 15 SCSI devices such as very large arrays of high-performance hard disk drives, external

More information

IBM 9910 UPSs for IBM iseries and pseries safeguard your equipment and data from power problems

IBM 9910 UPSs for IBM iseries and pseries safeguard your equipment and data from power problems Hardware Announcement April 20, 2004 IBM 9910 UPSs for IBM iseries and pseries safeguard your equipment and data from power problems Overview To meet the changing power protection needs of IBM servers,

More information

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Instruction Manual Basic Rack PDU VP7541 and VP9571A Instruction Manual Basic Rack PDU VP7541 and VP9571A VertivCo.com/geist Table of Contents Specifications... 3 Overview... 3 Environmental... 3 Temperature... 3 Humidity... 3 Elevation... 3 Electrical...

More information

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Back-UPS RS APC Back-UPS RS 800VA 120V Black Back-UPS RS APC Back-UPS RS 800VA 120V Black APC Back-UPS RS, 540 Watts / 800 VA,Input 120V / Output 120V Includes: CD with software, Cord management straps, Free trial of anti-virus : firewall : email

More information

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before

More information

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A Stacking Module AT-MCF2000S Installation Guide PN 613-000708 Rev A Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission

More information

Manual Version: V1.00. Video Decoder Quick Guide

Manual Version: V1.00. Video Decoder Quick Guide Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

1.0 Description. 2.0 Unpacking. 3.0 Installation

1.0 Description. 2.0 Unpacking. 3.0 Installation ES-H, ES-HA Series Precision Balance Thank you for purchasing the Model ES-H and ES-HA precision balance. Please read all operating instructions carefully before using and note the following items to ensure

More information

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during installation

More information

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview Overview Crowded data centers and racks filled to capacity with storage devices, monitors, servers communications devices, and other equipment are driving the need for uninterruptible power with increased

More information

PortServer II. Hardware Installation Guide C

PortServer II. Hardware Installation Guide C PortServer II Hardware Installation Guide 90000073C The Digi logo and PortServer II are trademarks of Digi International. All other brand and product names are trademarks of their respective holders. Digi

More information

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications AC Power For Business-Critical Continuity Liebert GXT3, 5kVA-10kVA UPS Systems: Big Protection, Small Package Today

More information

Infosystem Remote Touchscreen Installation Instructions

Infosystem Remote Touchscreen Installation Instructions Infosystem Remote Touchscreen Installation Instructions DOC. #569102100 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements

More information

Instruction Manual. Rack PDU XP Series. geistglobal.com

Instruction Manual. Rack PDU XP Series. geistglobal.com Instruction Manual Rack PDU XP Series geistglobal.com Table Of Contents 3 Table of Contents Specifications 4 Overview... 4 Environmental... 4 Tem perature... 4 Hum idity... 4 Elevation... 4 Electrical...

More information

Powerware P60/61

Powerware P60/61 ware 51405 9910 P60/61 Runtime and Rack Connections P60 & P61 Runtime and Rack Connections v5.ppt Battery Runtime Matrix Battery Runtime (in minutes)* Standard (Std) Watts Internal Batteries 1 EBM 2 EBMs

More information

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage.

More information

PowerNet RM SERIES 1500VA & 2200VA Line-interactive UPS USER MANUAL

PowerNet RM SERIES 1500VA & 2200VA Line-interactive UPS USER MANUAL PowerNet RM SERIES 1500VA & 2200VA Line-interactive UPS USER MANUAL Maruson Technology Corporation P.O. Box 1986, Walnut, CA 91788 USA Toll Free: 1-888-MARUSON Website: www.marusonusa.com E-Mail: Info@MarusonUSA.com

More information

SANnet II Family Safety, Regulatory, and Compliance Manual

SANnet II Family Safety, Regulatory, and Compliance Manual SANnet II Family Safety, Regulatory, and Compliance Manual March 2005 83-00002666, Revision F Copyright Copyright 2001-2005 Dot Hill Systems Corp. All rights reserved. No part of this publication may be

More information

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series www.eaton.com _ Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series 34008235EN/AC - Page 2 Introduction Thank you for selecting an EATON

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide Perle SMI Media Converter Installation Guide P/N 5500316-14 Overview This guide contains instructions necessary for the installation and operation of the Perle SMI Media Converter. This media converter

More information

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input. LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power

More information

Sync Control. Installation/Operation Manual Rev. E

Sync Control. Installation/Operation Manual Rev. E 9 315 Sync Control Installation/Operation Manual 164201140 Rev. E ------------------------------------------------------------------------ ------------------------------------------------------------------------

More information

9910 P18. Advanced power protection for mission-critical System p, System x, Storage and Networking rack products and applications. P18.

9910 P18. Advanced power protection for mission-critical System p, System x, Storage and Networking rack products and applications. P18. 9910 P18 Advanced power protection for mission-critical System p, System x, Storage and Networking rack products and applications 2002 Eaton Corporation. All rights reserved. P18.ppt P18 snapshot High

More information

NCH-1000 (Multiple Breaker Types) Installation Instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions 20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance

More information

RMB Peripheral Units Installation Guide

RMB Peripheral Units Installation Guide RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication

More information

Product Snapshot. the Powerware Uninterruptible Power System. Double-conversion, online design offers superior reliability and protection

Product Snapshot. the Powerware Uninterruptible Power System. Double-conversion, online design offers superior reliability and protection Powerware 9125 Uninterruptible Power System Product Focus 700-6000 VA Powerware 9125 6000 VA Features Protects mission-critical applications from downtime, data loss and corruption, and process interruption

More information

Safety and Radio-Frequency Interference

Safety and Radio-Frequency Interference FieldPoint Read Me First Safety and Radio-Frequency Interference This document contains safety instructions and information about the radio-frequency interference characteristics of the FieldPoint hardware.

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

Nevco Indoor LED Scoreboard Installation Manual

Nevco Indoor LED Scoreboard Installation Manual Nevco Indoor LED Scoreboard Installation Manual Retain this manual in your permanent file. Rev. 8/6/09 135-014 Installation Instructions Installation consists of three steps, Unpacking the Equipment, Scoreboard

More information

Dell Online Rack UPS 5600W. User's Guide. Dell 5600R OL HV-US, Dell 5600R OL HV K812N. w w w. d e l l. c o m s u p p o r t. d e l l.

Dell Online Rack UPS 5600W. User's Guide. Dell 5600R OL HV-US, Dell 5600R OL HV K812N. w w w. d e l l. c o m s u p p o r t. d e l l. Dell Online Rack UPS 5600W User's Guide Dell 5600R OL HV-US, Dell 5600R OL HV K812N w w w. d e l l. c o m s u p p o r t. d e l l. c o m Notes and Warnings NOTE: A NOTE indicates important information that

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. Pro Series DC Power Supply INSTRUCTION MANUAL 855-343-001 Models: ICT690-12S/ICT690-12SB ICT690-24S/ICT690-24SB ICT690-48S/ICT690-48SB ICT1190-12S/ICT1190-12SB ICT1190-24S/ICT1190-24SB

More information

3M RFID Tracking Pad Model 770

3M RFID Tracking Pad Model 770 3M RFID Tracking Pad Model 770 Owners Manual 3M Information and Materials Security 3M Center, Building 225-4N-14 St. Paul, Minnesota 55144-1000 xx-xxxx-xxxx-x Rev 1 Copyright 2003 3M IPC. All rights reserved.

More information

Neets Switching Relay - 2. Installation manual

Neets Switching Relay - 2. Installation manual Neets Switching Relay - 2 Installation manual Foreword The purpose of this document is to describe how to install and configure Neets Switching Relay 2 with build-in power supply. COPYRIGHT - All information

More information

Metro-Optical Transport Access Nodes

Metro-Optical Transport Access Nodes OnSite 1052 & 1063 Series Metro-Optical Transport Access Nodes Quick Start Guide Important This is a Class A device and isnot intended for use in a residential environment. Part Number: 07MOS10xx-QS, Rev.

More information

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative VFI RTG PDU 6-10K Installation and user manual Service and support: Call your local service representative SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. This manual contains important instructions that

More information

Zebra RW 420 Mobile Battery Eliminator Kits

Zebra RW 420 Mobile Battery Eliminator Kits Zebra Technologies Corporation 475 Half Day Road, Suite 500 Lincolnshire, IL 60069 USA Zebra RW 420 Mobile Battery Eliminator Kits Installation Instructions December, 2009 RW 420 Mobile Battery Eliminator

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information