1 Hardware Announcement April 20, 2004 IBM 9910 UPSs for IBM iseries and pseries safeguard your equipment and data from power problems Overview To meet the changing power protection needs of IBM servers, IBM Global Services has selected new Uninterruptible Power Systems (UPSs) from Powerware. The new IBM 9910 UPS solution, compatible with the power requirements for RS/6000, IBM pseries, AS/400, and iseries servers, has passed IBM s rigorous testing procedures and is intended to provide a convenient, single source for purchase and protection of IBM servers. All 9910 UPSs include a premium warranty package that is designed to enhance the potential for a return on investment over other UPSs available on the market today. In addition, the IBM warranty: Extends coverage of the UPS (refer to the specific product warranty period) Provides remote problem determination and next-day exchange (if available) by the UPS manufacturer (when necessary) Offers a single point of contact through the IBM Call Center IBM offers the following Powerware products for iseries and pseries servers: PW (P93) (three-phase model) incorporates a high level of service, design, and performance to help keep iseries and pseries servers working virtually without interruption. PW (P95) (three-phase model) provides advanced, feature-rich power management for iseries and pseries servers. P93 includes a one-year ProActive Service Plan. With the ProActive Service Plan, you receive service above the standard warranty. Extended Battery Module (EBM) (#6635) provides extended runtime (autonomy) for P93. EBM (#6636) provides extended runtime (autonomy) for P95. True online double-conversion three-phase power protection. ConnectUPS X-Slot Web/simple network management protocol (SNMP)/xHub option provides realtime monitoring of power conditions with Secure Socket Layer (SSL). Powerware kva (P30) and 6 kva (P64) provide true online, double-conversion UPSs with a versatile design that allows the UPS to be rack-mounted or installed as a tower. Key prerequisites The key prerequisites consist of the operating system and the selected applications that are required for your business. Planned availability dates April 20, 2004: Models P93, P95, and P64 July 20, 2004: Model P30 At a glance The IBM 9910 UPSs offer you: Models that are tested and approved by IBM An extended warranty supported by IBM A premium service package (including battery) Enhanced conditioning of utility power and battery backup Installation and startup by Powerware for Models P93 and P95 For ordering, contact: Your IBM representative, an IBM Business Partner, or the Americas Call Centers at 800-IBM-CALL Reference: YE001 This announcement is provided for your information only. For additional information, contact your IBM representative, call 800-IBM-4YOU, or visit the IBM home page at: IBM United States IBM is a registered trademark of International Business Machines Corporation

2 Description Powerware Uninterruptible Power Systems The Powerware 9330 Model 20 (P93) integrates advanced technology, software, and service capabilities into a single module capable of supporting critical servers, ISPs, telecommunications, or process control equipment. By incorporating DC Expert Plus Built-in Battery Monitoring and advanced communications, the P93 offers one of the highest levels of reliability for critical systems and one of the lowest overall cost of ownership for a double-conversion online UPS in the 20 kva range. The P93 includes a one-year ProActive Service Plan. With the ProActive Service Plan, you receive service above the standard warranty. Additional years of ProActive Service Plan can be ordered using feature numbers 7001 or To ensure all aspects of installation planning are taken into consideration, optional feature number 7005 can be ordered, which provides a site survey by an IBM installation planning representative. The Powerware 9305 Model 30 (P95) is designed to provide optimum protection with its double conversion online design, advanced communications capabilities, Advance Management (ABM) technology for doubled battery service life, and high reliability with Hot Sync parallel redundancy system. Specifically designed for use in server rooms or server farms for centralized power protection, the P95 offers the flexibility and some of the highest levels of power protection to critical IT equipment. The P95 includes a one-year ProActive Service Plan. With the ProActive Service Plan, you receive service above the standard warranty. The 9910-P30 (Powerware VA V ac single phase) UPS protects up to 2100 watts and the 9910-P64 (Powerware VA V ac single phase) UPS protects equipment up to 4200 watts. These true online, double-conversion UPSs feature ABM technology which doubles battery service life, load segments for schedule shutdowns (not available on P64) and extended runtimes, and a versatile design that allows the UPS to be mounted as a rack or a tower. Optional Extended Battery Modules (EBMs) extends battery runtimes, and the ConnectUPS Web/SNMP/xHub card adapter expands control and monitoring of UPS and network devices. To accommodate increased requests for rack UPS solutions for iseries models, the 9910 Model P33, previously announced in Hardware announcement , dated August 14, 2001, will be made available for iseries clients. Powerware offers the AS/400 Bundled X-Slot Relay Card (#2936) and a 25-foot (7.6 meters) AS/400 interface cable to provide a comprehensive solution for iseries rack clients. Accessibility by people with disabilities For hardware offerings, the following features support use by people with disabilities: Controls and latches are operable with one hand and minimal dexterity. Keys are discernible by touch without activating them. Ports and connectors support connection of industry-standard devices. Additional information All offers are subject to availability. IBM reserves the right to alter product offerings and specifications at any time without notice. IBM is not responsible for photographic or typographic errors. IBM makes no representation or warranty regarding third-party products or services. Trademarks iseries is a trademark of International Business Machines Corporation in the United States or other countries or both. RS/6000, AS/400, the e-business logo, and pseries are registered trademarks of International Business Machines Corporation in the United States or other countries or both. Other company, product, and service names may be trademarks or service marks of others

3 IBM US Announcement Supplemental Information April 20, 2004 Publications Product-specific publications are shipped with the products. Additional copies are available from the associated UPS supplier. Services Integrated technology services (IBM Global Services) IBM services range from business consulting, outsourcing, hosting services, applications, and other technology management. IBM technology services help you learn about, plan, install, manage, or optimize your IT infrastructure for e-business. We can help you integrate your high-speed networks, storage systems, application servers, wireless protocols, and an array of platforms, middleware, and communications software for IBM and many non-ibm offerings. IBM is your one-stop shop for IT support needs. Visit the appropriate link below for details on services available dependant on the brand the product belongs to. IBM pseries IBM iseries /inteapps.html For details on education offerings related to the products listed, visit /index.html Select your country; then select the product as the category. For more details on IBM Global Services capabilities, contact your IBM representative, or visit Your IBM representative can help you determine availability of standard and customized services. Technical information Specified operating environment Physical specifications: Physical specifications are subject to change. More detailed specifications can be obtained from your IBM representative or at the following Web site /Products/9910solutions/9910solutions.asp Model P30 (3000 VA, 2100 Watts) Depth: cm (23.9 in) Height: 8.89 cm (3.5 in), 2U Weight: kg (81.5 lb) Feature 6640 (Extended Battery Module for P30) Depth: cm (24.75 in) Height: 8.89 cm (3.5 in), 2U Weight: kg (93 lb) Feature 6570 (PowerPass Distribution Module for P30) Depth: 62.87cm (24.75 in) Height: 8.89 cm (3.5 in), 2U Weight: kg (50 lb) Model P64 (6000 VA, 4200 Watts) Depth: cm (24.94 in) Height: cm (8.63 in), 5U Weight: kg (206 lb) Feature 6641 (Extended Battery Module for P64) Depth: cm (24.75 in) Height: cm (5.25 in), 3U Weight: kg (169 lb) Feature 6571 (PowerPass Distribution Module for P64) Depth: cm (24.75 in) Height: cm (5.25 in), 3U Weight: kg (106 lb) Feature 6572 (PowerPass Distribution Module for P64) Depth: 62.87cm (24.75 in) Height: cm (5.25 in), 3U Weight: kg (106 lb) Feature 2936 (ConnectUPS Relay Card and Interface for P30, P33, P64, and P93) Width: inserts into X-Slot Depth: inserts into X-Slot Height: inserts into X-Slot Weight: 1 lb Feature 2938 (Environmental Monitoring Probe for Feature Numbers 2934 and 2935) Width: 3.76 cm (1.48 in) Depth: 5.76 cm (2.26 in) Height: 2.93 cm (1.15 in) Weight: 34 g (1.19 oz) This announcement is provided for your information only. For additional information, contact your IBM representative, call 800-IBM-4YOU, or visit the IBM home page at: IBM United States IBM is a registered trademark of International Business Machines Corporation

4 UPS Model P93 (20 kva) consists of two cabinets UPS (Power, electronics, and integral battery) cabinet Width: 56 cm (22 in) Depth: 79 cm (31 in) Height: 114 cm (45 in) Weight: kg (965 lb) Options (External maintenance bypass, output circuit breakers, and power distribution) cabinet Width: 56 cm (22 in) Depth: 97 cm (38 in) Height: 114 cm (45 in) Weight: 90 kg (200 lb) Feature 6635 (Extended battery cabinet for P93) Width: 52 cm (17 in) Depth: 79 cm (31 in) Height: 114 cm (45 in) Weight: 272 kg (600 lb) To verify the ability to be installed and serviced in non-ibm industry-standard racks, review the installation planning information for any product-specific installation requirements. Input/Output (I/O) configuration Input Plug/ Model Output Receptacles Connector P30 (4 ea) IEC-320-C13 10A, IEC-320-C20 16A (1 ea) IEC-320-C19 16A P64 (1 ea) L6-30R L6-30AR 6570 (2 ea) 5-15,(4 ea) 6-20 IEC-320-C20 16A (2 ea) L (2 ea) 5-15,(4 ea) 6-20 L6-30AR (2 ea) L6-15, L (8 ea) IEC-320 C13 10A, L6-30AR (4 ea) IEC-320 C19 16A, (1 ea) IEC309 P+N+G 32A 3 pin P93 (2 ea) 60A IEC309 Wired to Electric 460R9W Service Panel Operating environment Model P30 Operating temperature: 0 C to 40 C (32 F to 104 C) Storage temperature: 0 C to 25 C (32 F to 77 C) Relative humidity: 0% to 90%, non-condensing Audible noise at one meter: Less than 45 dba (on utility); less than 50 dba (on battery) Input voltage: Autosensing to nominal voltage of 208, 220, 230, or 240 V single phase Input voltage range: V single phase (without using batteries) Output voltage: 120/208 (with 6570 PPDM), 208, 220, 230, or 240 V single phase Model P64 Operating temperature: 0 C to 40 C (32 F to 104 C) Storage temperature: 0 C to 25 C (32 F to 77 C) Relative humidity: 5% to 90%, non-condensing Audible noise at one meter: Less than 45 dba (on utility); less than 50 dba (on battery) Input voltage: Autosensing to nominal voltage of 208, 220, 230, or 240 V single phase Input voltage range: V single phase (without using batteries) Output voltage: 120/208 (with 6571 PPDM), 208, 220, 230, or 240 V single phase Model P93 Operating temperature: 0 C to +40 C (32 F to 104 C) Storage temperature: -20 to +70 C (-4 F to 140 F) Relative humidity: 95% maximum, non-condensing Audible noise at one meter: Less than 60 dba Operation elevation: 1500 m (5000 ft) at 40 C without derating Input voltage: 120/208 V ac, 60 Hz, 3-phase + GND (rectifier); 208Y/120 V ac, 60 Hz, 3-phase + N + GND (Bypass) Output voltage: 208Y/120, 60 Hz Input voltage range: -15%, +10% Software requirements: The 9910 UPS solutions come with the Powerware Software Suite CD-ROM containing FREE LanSafe and NetWatch software. Powerware Extensions for IBM Director are FREE and downloadable from the Web. With comprehensive Network Power Management and 9910 UPS solutions from Powerware, you can realize key benefits of: Realtime information on network-wide power quality and events which affect system availability Control of power connected to individual or network devices Continuous clean power to each device Automatic and graceful shutdown of individual or network devices during extended power outages Monitoring to analyze and diagnose network problems Software to application matrix Powerware software Powerware LanSafe Extension for Application V5 NetWatch IBM Director single pseries X (serial/tty) non-lpar single pseries X 1 X 1 (network) non-lpar single pseries X 1 (LPAR) multiple pseries X X 1 (non-lpar) multiple pseries X 1 (LPAR) IBM Director X 1 network device Note: UPS for iseries applications utilize OS/400 UPS monitoring functions

5 1 Corequisite feature numbers 2934 or 2935 ConnectUPS Web/SNMP network card. Application comparison matrix Software Monitoring Shutdown GUI LanSafe Y Y Y Y NetWatch Y N/N ConnectUPS Web/SNMP Y 2 Y 3 Y Y/Y Card UPS SSL/SSH Ambient Application Security Temp/Humidity LanSafe N/N N/N NetWatch N/N N/N ConnectUPS Web/SNMP Card Y/Y Y 4 /Y 4 2 Via Web Browser, LanSafe or Network Management System 3 In conjunction with NetWatch software 4 With optional FN 2938 EMP (Environmental Monitoring Probe) device attached. The following LanSafe V5 operating systems are supported: Linux Redhat V7.1, 7.2, 7.3, 8.0, 9.0 Linux SuSE V7.2 AIX V4.1, 4.3.2, 4.3.3, 5.1, 5.2 The following NetWatch operating systems are supported: IBM AIX V4.x, 5.x (PowerPC ) Linux kernel V2.0 and higher (Intel ) Additional supported operating systems and information about Powerware UPS, network, enterprise-wide monitoring and control software can be found at the following Web site Planning information Customer responsibilities: The 9910 UPS Models P30 and P64 are designated as customer set-up, which includes installation of two battery trays for the P64, each weighing 59 pounds (27 kg). If Models P30, P64, and features 6640 and 6641 are not ordered with the iseries and pseries rack, the client will be responsible for the installation of external cables, UPS module, and battery module. Clients who request IBM service personnel to perform these activities are subject to a charge. Client responsibilities for the P30 and P64 include: Adequate site and system planning, and preparation Receipt, unpacking, and placement of the system unit Ordering, installing, and maintaining cables with associated parts for attaching to the pseries model Using and following the problem determination procedures in the operators guide Installing UPS management software and setting UPS run-time parameters The 9910 UPS Models P93 and P95 are designated as a combination Powerware installation and customer set-up. If feature number 6635 and/or 6636 is not ordered with the UPS (P93, P95), the client will be responsible for installation of these features. Clients who request IBM service personnel to perform these activities are subject to a charge. Client responsibilities for Models P93 and P95 include: Adequate site and system planning and preparation with support from IBM and Powerware personnel Receipt, positioning of the system unit at ground level to installation area Ordering, installing, and maintaining cables with associated parts for attaching to the pseries model Using and following the problem determination procedures in the operators guide Installing UPS management software and setting UPS run-time parameters Cable orders 9910 Model P93 Power (electrical) cables The input (mains) power to the 9910-P93 is hardwired by a Powerware installation contractor into a client-provided power distribution panel. Refer to the Machine installation section for installation service description. Two types of output power distribution connection outlets (receptacles) are available, feature numbers 9880 and The base P93 includes one feature number 9880 which contains two 60A, 3-phase, 4-wire IEC R9W connectors with appropriate circuit breakers and connectors. Each connector shall be on a maximum 50-foot cord. This feature number supports dual-redundant power cords of the base processor frame or CPU. The maximum quantity of feature number 9880 is one. Optional output power distribution connections are available with feature number Each feature number 9881 contains three 15 A to 30 A NEMA non or locking receptacle with appropriate circuit breakers and connectors (power cord). Each connector shall be on maximum 50-foot cord and wired into the Options Cabinet output distribution panel. The description of the Options Cabinet is as follows: Option Cabinet 20 kva capacity, single feed, 208/208, maintenance bypass, and 42-pole panel with output connection housing. Valid receptacle types are: NEMA; 5-15R2, 5-20R2, L5-15R, L5-20R, 30R, L5-30R, 6-15R, L6-15R, 6-20R, L6-20R; and, L6-30R. Note: 15 A and 20 A non-locking, low voltage (5-15R2 and 5-20R2) are duplex (two receptacles). The minimum quantity of feature number 9881 is zero. The maximum quantity of feature number 9881 is six. Feature numbers 9880 and 9881 will be installed to the P93 configuration at time of UPS installation. The IEC and NEMA plug types used in feature numbers 9880 and 9881 correspond to IBM plug types

6 Refer to the following: IEC/NEMA Type IEC R9W NA L L L L L L NA = Not applicable IBM Plug Type If the plug type selected for the equipment to be protected by the 9910-P93 is not contained in this table, change the plug type on the equipment to match plug types available with feature numbers 9880 or Feature 6635 (External Battery Module) The input power to the 6635 is DC and is provided by the P93. If installation of 6635 is concurrent to P93, installation of the DC cable is hardwired by a Powerware installation contractor at installation. Feature number 6635 is a line-up-and-match cabinet connected to P93 cabinet. If installation of 6635 is non-concurrent or a Miscellaneous Equipment Specification (MES), installation is the responsibility of the client. Communications cables One iseries (AS/400 ) to UPS interface cable (25 ft/7.6 m length) and one server to UPS serial TTY interface cable DB9 to DB9 (6 ft/1.8 m length) are included with the P93 for iseries and pseries orders. To use the Remote Notify capability of the P93, the provided serial port will be connected to a provided modem. The modem will require a client-supplied dedicated (analog) telephone line. There are two unused communications ports available for optional communications cards (#2933, #2934, or #2936). The optional feature number 2933 (ConnectUPS MultiServer Card) includes three server to UPS serial TTY interface cables DB9 to DB9 (6 ft/1.8 m length). Note: This feature number is used to serially communicate with two or three servers. The optional feature number 2934 (ConnectUPS Web/SNMP/xHub Card) includes one UPS to Web Card configuration cable RJ45 to DB9M (6 ft/1.8 m length). Note: This feature number is required if using LPAR on pseries. The optional feature number 2936 (ConnectUPS Relay Card and Interface Cable) includes iseries (AS/400) to UPS interface cable (25 ft/7.6 m length). The optional feature number 2938 (ConnectUPS EMP) includes one CAT5 cable (6 ft/1.8 m length). Corequisite is feature number Min: 0, Max: 1 feature number 2938 per feature number Model P95 Power (electrical) cables The input (mains) power to the 9910-P95 is hardwired by a Powerware installation contractor into a client-provided mains distribution panel. Refer to the Machine installation section for installation service description. Three output power distribution connection outlets (receptacles) are available, feature numbers 9883, 9884, and Cabling Option A (#9884) includes one 32A 3-phase commando 5-hole (TPN&E) 415 V socket (floor mountable, angled as per RS ) attached to 4 mm two 5-core steel wire armoured (SWA), low smoke and fume (LSF)-type mains cable, 12 meters long; and one unconnected 32A 3-phase commando 5-hole (TPN&E) 415 V plug (straight free plug as per RS ). Presentation: Cable to be pre-terminated to socket. Plug to be married to socket connector. Cabling Option B (#9885) includes three 32A 1-phase commando 3-hole (SPN&E) 240 V socket (floor mountable, angled as per RS ) each attached to 4 mm two 3-core SWA, LSF-type mains cable, 12 meters long; and three unconnected 32A 1-phase commando 3-hole (SPN&E) 240 V plugs (straight free plug as per RS ). Presentation: Cable to be pre-terminated to socket. Plug to be married to socket connector. Cabling Option C (#9883) includes three 16A 1-phase commando 3-hole (SPN&E) 240 V socket (floor mountable, angled as per RS ) each attached to 4 mm two 3-core SWA, LSF-type mains cable, 12 meters long; and three unconnected 16A 1-phase commando 3-hole (SPN&E) 240 V plugs (straight free plug as per RS ). Presentation: Cable to be pre-terminated to socket. Feature numbers 9883, 9884, and 9885 will be installed to the P95 configuration at time of UPS installation. Feature 6636 (External Battery Module) The input power to the 6636 is DC and is provided by the P95. If installation of 6636 is concurrent to P95, installation of the DC cable is hardwired by a Powerware installation contractor at INSTALLATION. Feature number 6636 is a line-up-and-match cabinet connected to P95 cabinet. If installation of 6636 is non-concurrent or a MES, installation is the responsibility of the client. Communications cables One iseries (AS/400) to UPS interface cable (15 ft/5 m length) and one server to UPS serial TTY interface cable DB9 to DB9 (6 ft/2 m length) are included with the P95 for iseries and pseries orders. The optional feature number 2935 (ConnectUPS E (external) Web/SNMP adapter) includes one UPS to ConnectUPS Adapter configuration cable 9PinM (P95) to 25PinF (ConnectUPS) (6 ft/1.8 m length). Note: This feature number is required if using LPAR pseries. The optional feature number 2938 (ConnectUPS Environmental Monitoring Probe (EMP)) includes one CAT5 cable (6 ft/1.8 m length). Corequisite is feature number Min: 0, Max: 1 feature number 2938 per feature number Model P30 Power (electrical) cables The input (mains) power connection to the 9910-P30 is an IEC-320-C20 (16A) connector. The input (mains) power cord from the UPS to the utility (mains) is determined based upon country or locality. Refer to the following 9910-P30 input power cord table:

7 Feature Plug number type Plug description Length NEMA L ft/4.4 m NEMA L ft/1.8 m CEE7 VII 14 ft/4.4 m SABS ft/4.4 m CEI ft/4.4 m IEC309 (P+N+G) 16A 14 ft/4.4 m SII ft/4.4 m SAA -AS ft/4.4 m IEC A5 14 ft/4.4 m When the 9910-P30 is employed in a rack installation (iseries or pseries) or in a tower configuration for world trade countries, the P30 output (receptacle) configuration is four IEC-320-C13 (10A) and one IEC-320-C19 (16A). The 9910-P30 also includes five (5) output power cable consisting of four IEC-320-C13 to C14 (6 ft/1.8 m length) and one IEC-320-C19 to C20 (14 ft/4.4 m length). These power cables are located in the Power Cord Kit carton, IBM feature number A maximum of one feature number 9830 is supported. When the 9910-P30 is employed in a tower configuration in NEMA-type countries, the P30 will include one NEMA-type PowerPass Distribution Module (PPDM) IBM feature number 6570, which contains the following output (receptacle) connections. IBM plug types supported are referenced. Feature 6570 output connection table IBM plug Qty types NEMA type provided supported 5-15/ / /29 L If the plug type selected for the equipment to be protected by the 9910-P30 is not contained in this table, change the plug type on the equipment to match plug types available with feature number Power electrical cable installation diagrams are at the following Web sites: NEMA countries /nemadiagm.pdf IEC countries /iecdiagm.pdf Feature 6640 (External Battery Module) The input power to the 6640 is DC and is provided by the P30. Connection of the 6640 DC cable (Anderson-type DC connector) is the responsibility of the client and is performed at installation. Feature number 6640 is a line-up-and-match cabinet connected to P30 cabinet. Communications cables One server to UPS serial TTY interface cable DB9M to DB9F (6 ft/1.8 m length) is included with the P30 (contained in the P30 Accessory Kit carton) for all (iseries and pseries) orders. The P30 includes a single serial port (DB9) contained on a removable ConnectUPS X-Slot interface card. Optional communications features (#2933, #2934, and #2936) will replace this single port serial card. A maximum of one feature number 2933, or 2934, or 2936 is supported. The optional feature number 2933 (ConnectUPS MultiServer Card) includes three server UPS serial TTY interface cables DB9 to DB9 (6 ft/1.8 m length). Min: 0, Max: 1 per P30. Note: This feature number is used to serially communicate with two or three servers. The optional feature number 2934 (ConnectUPS Web/SNMP/xHub Card) includes one UPS to Web Card configuration cable RJ45 to DB9M (6 ft/1.8 m length). Note: This is required if using LPAR on pseries. Min: 0, Max: 1 per P30. The optional feature number 2936 (ConnectUPS Relay Card) includes one iseries (AS/400) to UPS interface cable (25 ft/7.6 m length). This feature number is included with iseries orders. Min: 0, Max: 1 per P30. The optional feature number 2938 (ConnectUPS Environmental Monitoring Probe (EMP)) includes one CAT5 cable (6 ft/1.8 m length). Corequisite is feature number Min: 0, Max: 1 feature number 2938 per feature number Model P64 Power (electrical) cables The input (mains) power connection to the 9910-P64 is a NEMA L6-30AR (30A) connector. The input (mains) power cord from the UPS to the utility (mains) is determined based upon country or locality. Refer to the following 9910-P64 input power cord table: Feature Plug number type Plug description Length NEMA L ft/4.4 m NEMA L ft/1.8 m RS ft/1.8 m RS ft/4.4 m IEC309 (P+N+G) 32A 14 ft/4.4 m 1425 KP KP 14 ft/4.4 m 1426 PDL PDL 14 ft/4.4 m 1427 PDL PDL-NZ 14 ft/4.4 m When the P64 is used as a RACK model and the PDU is feature number 5160, 7176, or 9176 (NEMA type), none of the above power cables are needed. The power cord shipped for the PDU is used from the P64 to the wall (mains). Feature number 2970 is used to the NEMA PDU to the output receptacle of the P64. Feature number 2970 is one power NEMA L6-30P to NEMA L6-30R (6 ft./1.8 m length). When the P64 is used as a RACK model and the PDU is feature number 5161, 7177, or 8177 (IEC type), the above cables are needed. Feature number 2971 is used to connect the IEC PDU to the output receptacle of the P64. Feature number 2971 is one power cord, NEMA L6-30P to IEC309 (P+N+G) 32A receptacle (6 ft/1.8 m length). Output PDU to UPS power cord table Feature Plug Receptacle number type type Length 2970 for PDU NEMA NEMA L ft/1.8 m 5160, 7176 L6-30 or for PDU NEMA IEC309 6 ft/1.8 m 5161, 7177 L6-30 (P+N+G) or A

8 When the 9910-P64 is employed in a tower configuration in NEMA-type countries, the P64 will include one NEMA-type PowerPass Distribution Module (PPDM) IBM feature number 6571, which contains output (receptacle) connections described in the feature number 6571 output connection table. IBM plug types supported are referenced. Feature number 6571 output connection table IBM plug Qty types NEMA type provided supported 5-15/ / /29 L L If the plug type selected for the equipment to be protected by the 9910-P4 is not contained in this table, change the plug type on the equipment to match plug types available with feature number When the 9910-P64 is employed in a tower configuration in world trade countries, the P64 will include one IEC-type PPDM IBM feature number 6572, which contains output (receptacle) connections described in the feature number 6572 output connection table. IBM plug types supported are referenced. This 9910-P64 configuration includes two sets of five output power cables consisting of: four (4) IEC-320-C13 to C14 (6 ft/1.8 m length) and one IEC-320-C19 to C20 (14 ft/4.4 m length). These power cables are located in the Power Cord Kit cartons, IBM feature number A maximum of two feature number 9830s are supported. In addition to the two feature number 9830s, feature number 6572 contains two IEC-320-C19 to C20 (14 ft/4.4 m length) power cords and are located in the 6572 carton. Feature 6572 output (receptacle) connection table IBM plug Qty types IEC type provided supported IEC-320-C13 8 (10A) IEC-320-C19 4 (16A) IEC309 (P+N+G) 1 46 (32A) If the plug type selected for the equipment to be protected by the 9910-P64 is not contained in this table, use the output power cables contained in feature number A summary of output power cords included with the 9910-P64 and feature number 6572 configuration is contained in the following table: 9910-P64 with feature 6572 and two feature 9830 output power cord table Receptacle Plug type type Length Quantity IEC-320-C14 IEC-320-C13 6 ft/1.8m 8 IEC-320-C20 IEC-320-C19 14 ft/4.4m 4 Power electrical cable installation diagrams are located at the following Web sites: NEMA countries /nemadiagm.pdf IEC countries /iecdiagm.pdf Feature 6641 (External Battery Module) The input power to the 6641 is DC and is provided by the P64. Connection of the 6641 DC cable (Anderson-type DC connector) is the responsibility of the client and is performed at installation. Feature number 6641 is a line-up-and-match cabinet connected to P64 cabinet. Communications cables One server to UPS serial TTY interface cable DB9M to DB9F (6 ft/1.8 m length) is included with the P64 (contained in the P64 Accessory Kit carton (IBM part number 38P9309)) for all (iseries and pseries) orders. The P64 includes a single serial port (DB9) and a USB port, both are contained on the backplane of the device. An empty ConnectUPS X-Slot interface port is available for optional communications features (#2933, #2934, and #2936). Communications is employed in an or configuration: serial or USB or ConnectUPS card. A maximum of one feature number 2933, or 2934, or 2936 is supported. The optional feature number 2933 (ConnectUPS MultiServer Card) includes three server to UPS serial TTY interface cables DB9 to DB9 (6 ft/1.8 m length). Min: 0, Max: 1 per P64. Note: This feature number is used to serially communicate with two or three servers. The optional feature number 2934 (ConnectUPS Web/SNMP/xHub Card) includes one UPS to Web Card configuration cable RJ45 to DB9M (6 ft/1.8 m length). Note: This is required if using LPAR on pseries. Min: 0, Max: 1 per P64. The optional feature number 2936 (ConnectUPS Relay Card) includes one iseries (AS/400) to UPS interface cable (25 ft/7.6 m length). This feature number is included with iseries orders. Min: 0, Max: 1 per P64. The optional feature number 2938 (ConnectUPS EMP) includes one CAT5 cable (6 ft/1.8 m length). Corequisite is feature number Min: 0, Max: 1 feature number 2938 per feature number Security, auditability, and control The customer is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities. Terms and conditions This product is available for purchase under the terms of the IBM Customer Agreement. Each IBM Machine is manufactured from parts that may be new or used. In some cases, a Machine may not be new and may have been previously installed

9 Regardless, IBM s appropriate warranty terms apply. IBM Global Financing: No Warranty period: This product is available for purchase under the terms of the IBM Customer Agreement. IBM hardware products are manufactured from new parts, or new and used parts. In some cases, the hardware product may have been previously installed. Regardless, IBM warranty terms apply. Models P30 and P64 have a five-year Advanced Element Exchange Warranty (including battery) provided by Powerware with IBM as point of contact. Model P93 has a five-year, on-site, Next-Business-Day (NBD) Warranty provided by Powerware with IBM as point of contact. When a type of service involves the exchange of a machine part, the replacement may not be new, but will be considered equivalent to new. Warranty Service IBM 9910 UPS Models P30 and P64 provide a premium Element Exchange Warranty. In case of problems with the UPS, contact IBM Service Support. IBM will coordinate remote diagnostics and manage the Element Exchange Warranty, if necessary. If a replacement element is required, the UPS manufacturer will process and ship the request the same day if the request is received before noon (12:00 p.m.) local time. After noon, the replacement element will be shipped the following business day. The replacement element will be next-day air service (same type of carrier used in the U.S., for example, Federal Express, Airborne Express). The shipping costs to and from the client location are the responsibility of the UPS manufacture. Advanced Element Exchange Warranties DO NOT include on-site service unless specifically noted in writing at the time of equipment sale. IBM 9910 Models P93 and P95 provide on-site, NBD service. In case of problems with the UPS, contact IBM Service Support. IBM will coordinate having a Powerware Service representative on site to perform diagnostics and repair action if necessary. A Powerware Service Representative will arrive the next business day (P95 most countries) when the service request is placed before noon local time. If the service request is received after noon local time, the Powerware representative will be on site the second business day after the service request was placed. In addition, Powerware offers optional ProActive Warranty Service Plans feature number 7001 concurrent (one additional year) or feature number 7002 non-concurrent (one additional year). The ProActive service plan includes: 24x7 corrective maintenance coverage. 24x7 annual performance check. Annual power protection audit. 24x7 remote monitoring advance response service 5. Monthly UPS performance report 5. Web access to account information and site service activity. Feature number 7001: One additional year of ProActive Warranty Service Plan. Concurrent to purchase of P93. Min: 0, Max: 4. Must be purchased at the same time the P93 is ordered. Feature number 7002: One additional year of ProActive Warranty Service Plan. Non-concurrent to purchase of P93. Min: 0, Max: 4. 5 Requires use of P93 modem and client-provided dedicated analog (outside) phone line. Note: One year of ProActive Warranty Service is included in the purchase price of the P93. Client responsibility For 9910 Models P30 and P64, the clients responsibilities for element exchange are: Receipt, unpacking, and exchange of the defective element. Packaging of the defective element in the container received with the replacement element. Following the instructions provided for return of the defective element. Returning the defective element so that it is received at Powerware UPS Systems depot center within the established time from the arrival of the replacement. For 9910 Models P93 and P95, the client will be contacted to coordinate the on-site service provided by Powerware. Powerware maintains a 24-hour hotline for technical support at in the U.S. and Canada, or Contact the local Powerware agent for all other countries. Technical information can also be accessed at the following Web site /9910solutions/9910solutions.asp Warranty service is available from IBM Field Support Services Center at 800-IBM-SERV ( ). Usage plan machine: No IBM hourly service rate classification: Two These machines are not under the IBM Maintenance Agreement. Contact your local IBM Services Branch office for Post Warranty Options. When a type of service involves the exchange of a machine part, the replacement may not be new, but will be in good working order. Field-installable features: Yes Model conversions: No Machine installation: Customer Setup, customers are responsible for installation according to the instructions IBM provides with the Machine. Graduated charges: No. These products do not contain Licensed Internal Code or Licensed Machine Code. Educational allowance: A reduced charge is available to qualified education customers. The educational allowance may not be added to any other discount or allowance

10 Educational Allowance A reduced charge is available to qualified education clients. The educational allowance may not be added to any other discount or allowance. The educational allowance is 15% for the products in this announcement. Product charges UPS Prices Machine Feature Description type Model number Price CSU Powerware kva tower or 9910 P30 $ 3,082 Yes rack-mount Powerware kva Battery 9910 P Yes Module Powerware kva tower PPDM 9910 P Yes (NEMA dist. module) Powerware kva tower or 9910 P64 4,411 Yes rack-mount Powerware kva Battery 9910 P Yes Module Powerware Rail Kit A 9910 P Yes Powerware kva tower PPDM 9910 P Yes (NEMA dist. module) Powerware kva tower PPDM 9910 P Yes (IEC dist. module) Powerware X-Slot Relay Card/Cable 9910 P30/P Yes P33 Powerware jumper cord kit 9910 P30/P Yes (IEC plugs) for iseries Rack P33 P30 tower w/o PPDM P64 tower with IEC PPDM (2 sets) Powerware Environmental Probe 9910 All Yes for 2934 and 2935 Power Cord L6-30 to L ft 9910 P Yes PDU to UPS Power Cord/Redundant Power Source 9910 P30/P Yes IBM Plug Type ft Power Cord/Redundant Power Source 9910 P30/P Yes IBM Plug Type ft Power Cord/Redundant Power Source 9910 P30/P Yes IBM Plug Type ft Power Cord/Redundant Power Source 9910 P30/P Yes IBM Plug Type 11 6 ft Power Cord L6-30 to L ft 9910 P Yes Power Cord L6-30 to L ft 9910 P Yes Power Cord L6-30 to Russellstoll 9910 P Yes 6 ft Power Cord L6-30 to Russellstoll 9910 P Yes 14 ft Power Cord L6-30 to Korea 30A 9910 P Yes Power Cord L6-30 to Australia 30A 9910 P Yes (PDL) Power Cord L6-30 to New Zealand 9910 P Yes 30A (PDL) Factory Installation of MT 9910 in 9910 P30/P NC NA iseries rack P33 Field Installation of MT 9910 in 9910 P30/P NC NA iseries rack Tower Form Factor 9910 P30/P NC NA Rack Cont. Specify: 9910/P30-2EIA 7014 T00/T NC NA (UPS, 6 C13 Outlets) Rack Cont. Specify: 9910/6640-2EIA 7014 T00/T NC NA (9910-P30 Battery Module) Rack Cont. Specify: 9910/P64-5EIA 7014 T00/T NC NA (UPS, 6 C13 Outlets)

11 Machine Feature Description type Model number Price CSU Rack Cont. Specify: 9910/6641-3EIA 7014 T00/T NC NA (9910-P64 Battery Module) Powerware kva 9910 P93 $38,345 No Powerware Extended Battery Module 9910 P ,311 No (EBM) for P93 IBM IPR Site Survey 9910 P No ProActive Warranty Service Plan 9910 P ,596 No Concurrent (One additional year) ProActive Warranty Service Plan 9910 P ,272 No Non-Concurrent (One additional year) Output Connections, two IEC 60A 9910 P ,617 No Output Connections, three NEMA 15A 9910 P ,084 No to 30A NC = No Charge NA = Not Applicable CSU = Customer Set-Up Field Plant MES MES install install MES removal add only only removal charge charge N N N NC NC Order now To order, contact the Americas Call Centers, your local IBM representative, or your IBM Business Partner. To identify your local IBM representative or IBM Business Partner, call 800-IBM-4YOU ( ). Phone: 800-IBM-CALL ( ) Fax: 800-2IBM-FAX ( ) Internet: ibm direct@vnet.ibm.com Mail: IBM Americas Call Centers Dept: IBM CALL, 6th Floor 105 Moatfield Drive North York, Ontario Canada M3B 3R1 Reference: YE001 The Americas Call Centers, our national direct marketing organization, can add your name to the mailing list for catalogs of IBM products. Note: Shipments will begin after the planned availability date. Trademarks iseries is a trademark of International Business Machines Corporation in the United States or other countries or both. pseries, the e-business logo, OS/400, AIX, PowerPC, AS/400, and SAA are registered trademarks of International Business Machines Corporation in the United States or other countries or both. Intel is a trademark of Intel Corporation. Other company, product, and service names may be trademarks or service marks of others

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems IBM United States Hardware Announcement 110-077, dated May 18, 2010 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Table of contents 1 Overview 2 Product number

More information

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems IBM Latin America Hardware Announcement LG10-0100, dated May 18, 2010 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Table of contents 1 Overview 2 Product

More information

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems IBM United States Announcement 108-068, dated January 29, 2008 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Key prerequisites...2 Description...2 Publications...

More information

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems IBM United States Hardware Announcement 111-139, dated July 26, 2011 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Table of contents 1 Overview 3 Publications

More information

Powerware P95

Powerware P95 Powerware 93059 9910 - P95 Reliable power with proven double conversion online technology p95pres.ppt Rev 15.04.04 1 P95 Features Double-conversion, online technology protects against the 9 power problems

More information

Powerware P64

Powerware P64 Powerware 91259 9910 - P64 High Performance High Reliability & Availability Flexible & Configurable Advanced Communications p64pres.ppt rev 4.16.04 1 P64 Features Double-conversion online High-power density

More information

Powerware 9910-P11 and 9910-P16

Powerware 9910-P11 and 9910-P16 Powerware 9910-P11 and 9910-P16 High Performance High Reliability & Availability Flexible & Configurable Advanced Communications 2002 Eaton Corporation. All rights reserved. P11 and P16 Features Fourth-Generation

More information

IBM TotalStorage FAStT Storage Servers provides support for IBM systems running the Linux for Power operating system

IBM TotalStorage FAStT Storage Servers provides support for IBM systems running the Linux for Power operating system Hardware Announcement April 27, 2004 IBM TotalStorage FAStT Storage Servers provides support for IBM systems running the Linux for Power operating system Overview IBM TotalStorage FAStT Storage Servers

More information

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Hardware Announcement ZG09-0284, dated July 28, 2009 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Table of contents 1 At a glance 3 Publications 1 Overview

More information

Cisco MDS 9000 Port Analyzer Adapter, Enhanced: New version improves performance monitoring

Cisco MDS 9000 Port Analyzer Adapter, Enhanced: New version improves performance monitoring Hardware Announcement April 27, 2004 Cisco MDS 9000 Port Analyzer Adapter, Enhanced: New version improves performance monitoring Overview The Cisco MDS 9000 family is designed to offer investment protection,

More information

9910-UPS Rack Chart Updated Oct 05

9910-UPS Rack Chart Updated Oct 05 All devices and UPS in One rack? es One to Two* or Two or Four** 9188-7188 PDUs? es es If LPAR s or Web/SNMP connectivity (interface) required, select FC 934 If no LPAR s ensure p5 has #573 for serial

More information

IBM 7212 Model 102 adds Half-High LTO Tape Drive for IBM pseries and iseries

IBM 7212 Model 102 adds Half-High LTO Tape Drive for IBM pseries and iseries Hardware Announcement October 4, 2005 IBM 7212 Model 102 adds Half-High LTO Tape Drive for IBM pseries and iseries Overview The IBM 7212 Model 102 TotalStorage Storage Device Enclosure adds the 200/400

More information

Configuration Questions:

Configuration Questions: Configuration Questions: 1 What equipment will be protected? Calculate using Table 1 What do I want the UPS to do? Shutdown server(s) interface? Provide extended battery (autonomy) runtime? 3 Where do

More information

IBM 3996 Optical Library offers expansive optical storage for data retention

IBM 3996 Optical Library offers expansive optical storage for data retention Hardware Announcement May 9, 2006 IBM 3996 Optical Library offers expansive optical storage for data retention Overview The IBM 3996 Optical Library is a large-scale, externally attached device that uses

More information

Family Uninterruptible Power System (UPS) for RS/6000/pSeries IBM U.S. Sales Manual Revised: October 10, 2005.

Family Uninterruptible Power System (UPS) for RS/6000/pSeries IBM U.S. Sales Manual Revised: October 10, 2005. Page 1 of 39 Family 9910+01 Uninterruptible Power System (UPS) for RS/6000/pSeries IBM U.S. Sales Manual Revised: October 10, 2005. Table of contents Document options IBM U.S. Product Life Cycle Dates

More information

IBM 3996 Optical Library offers expansive optical storage for data retention

IBM 3996 Optical Library offers expansive optical storage for data retention Hardware Announcement October 11, 2005 IBM 3996 Optical Library offers expansive optical storage for data retention Overview The IBM 3996 Optical Library is designed for excellent reliability and performance.

More information

Configuration Questions:

Configuration Questions: Configuration Questions: 1 What equipment will be protected? Calculate using Table 1 What do I want the UPS to do? Shutdown server(s) interface? Provide extended battery (autonomy) runtime? 3 Where do

More information

IBM System p5 570 POWER5+ processor and memory features offer new options

IBM System p5 570 POWER5+ processor and memory features offer new options Hardware Announcement February 14, 2006 IBM System p5 570 POWER5+ processor and memory features offer new options Overview The System p5 570 offers new POWER5+ processor options with 64-bit 1.9 GHz and

More information

IBM System p5 505 and System p5 505Q offer four new processor options

IBM System p5 505 and System p5 505Q offer four new processor options Hardware Announcement July 25, 2006 IBM System p5 505 and System p5 505Q offer four new processor options Overview The System p5 505 offers new POWER5+ processor options with the 1-core, 1.9 GHz processor

More information

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus Powerware 9120 Uninterruptible Power System Product Focus Product Snapshot Power Rating: 700-3000VA Voltage: 120 and 230 Vac Frequency: 50/60 Hz (auto-sensing) Configuration: tower Features True double-conversion

More information

New IBM 10 Gigabit Ethernet-SR PCI-X adapter

New IBM 10 Gigabit Ethernet-SR PCI-X adapter Hardware Announcement July 13, 2004 New IBM 10 Gigabit Ethernet-SR PCI-X adapter now available for IBM pseries systems Overview The following 10 Gigabit Ethernet-SR adapter is now available for pseries

More information

IBM TotalStorage 2104 Expandable Storage Plus 320 offers new high-performance disk drive capacity

IBM TotalStorage 2104 Expandable Storage Plus 320 offers new high-performance disk drive capacity Hardware Announcement April 19, 2005 IBM TotalStorage 2104 Expandable Storage Plus 320 offers new high-performance disk drive capacity Overview The IBM TotalStorage Exp Plus 320 now offers the option of

More information

IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions

IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions Hardware Announcement February 17, 2003 IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions Overview The IBM TotalStorage FAStT900 Storage Server expands the family

More information

IBM TotalStorage SAN portfolio expands with IBM TotalStorage SAN04M-R router

IBM TotalStorage SAN portfolio expands with IBM TotalStorage SAN04M-R router Hardware Announcement July 26, 2005 IBM TotalStorage SAN portfolio expands with IBM TotalStorage SAN04M-R router Overview The IBM TotalStorage SAN m-type family of products expands with the introduction

More information

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments Powerware 9140 Uninterruptible Power System Product Focus Superior de-centralized power protection for medium- and high-density rack environments Product Snapshot Features Protects mission-critical rackmount

More information

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide The IBM 1U Switched and Monitored Power Distribution Units (PDUs) make it quick and simple to deploy, protect, and

More information

IBM p5 520 and way and 2-way 1.5 GHz processors offer new processor speed options

IBM p5 520 and way and 2-way 1.5 GHz processors offer new processor speed options Hardware Announcement October 5, 2004 IBM p5 520 and 550 1-way and 2-way 1.5 GHz processors offer new processor speed options Overview IBM p5 520 and 550 offer new POWER5 processor options with the optional

More information

Powerware 9120 UPS. Product Snapshot. Features

Powerware 9120 UPS. Product Snapshot. Features Powerware 9120 UPS Features True double conversion online technology give you protection from all nine power problems Simple installation and operation Intuitive LCD screen provides realtime updates of

More information

9155 UPS mdspower.com

9155 UPS mdspower.com Eaton Product Introduction Product Snapshot Technology: Split-phase double-conversion online Power Rating: 8 kva, 10 kva, 12 kva and 15 kva at 0.9 power factor Input Voltage: 200 240 Vac with Neutral or

More information

IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide

IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide The IBM UPS5000 HV is a 5 KVA rack-mountable uninterruptible power supply (UPS) that utilizes advanced backup power technology

More information

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview Overview Crowded data centers and racks filled to capacity with storage devices, monitors, servers communications devices, and other equipment are driving the need for uninterruptible power with increased

More information

IBM 7206 External Tape Drive Model VX3 delivers increased storage capacity

IBM 7206 External Tape Drive Model VX3 delivers increased storage capacity Hardware Announcement April 11, 2006 IBM 7206 External Tape Drive Model VX3 delivers increased storage capacity Overview The IBM 7206 Model VX3 External Tape Drive is a stand-alone, SCSI, VXA-320 streaming

More information

Cisco MDS 9000 Enhancements Fabric Manager Server Package Bundle, Mainframe Package Bundle, and 4 Port IP Storage Services Module

Cisco MDS 9000 Enhancements Fabric Manager Server Package Bundle, Mainframe Package Bundle, and 4 Port IP Storage Services Module Hardware Announcement April 27, 2004 Cisco MDS 9000 Enhancements Fabric Manager Server Package Bundle, Mainframe Package Bundle, and 4 Port IP Storage Services Module Overview The Cisco MDS 9000 family

More information

Powerware P60/61

Powerware P60/61 ware 51405 9910 P60/61 Runtime and Rack Connections P60 & P61 Runtime and Rack Connections v5.ppt Battery Runtime Matrix Battery Runtime (in minutes)* Standard (Std) Watts Internal Batteries 1 EBM 2 EBMs

More information

Powerware Software Connectivity Service. > Powerware Software Suite ensures data integrity; free updates on

Powerware Software Connectivity Service. > Powerware Software Suite ensures data integrity; free updates on Powerware 9120 Features True double conversion online technology give you protection from all nine power problems Simple installation and operation Intuitive LCD screen provides realtime updates of UPS

More information

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch SmartOnline 200-240V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch MODEL NUMBER: SU6000RT4UHVG Highlights 6kVA / 6000VA / 5400W on-line

More information

QuickSpecs. HP Tower UPS T750 G2, T1000 G3, T1500 G3 Overview

QuickSpecs. HP Tower UPS T750 G2, T1000 G3, T1500 G3 Overview Overview HP Tower Uninterruptible Power Systems (UPS) provide advanced power protection and secure your computer equipment and your critical data against damage due to inconsistent and fluctuating power.

More information

Expanded IBM System i5 Capacity BackUp (CBU) Editions Now more flexible for your system backup needs

Expanded IBM System i5 Capacity BackUp (CBU) Editions Now more flexible for your system backup needs Hardware Announcement August 8, 2006 Expanded IBM System i5 Capacity BackUp (CBU) Editions Now more flexible for your system backup needs Overview IBM expands the range of CBU Editions for System i5 servers.

More information

T1000 G2 and T1500 G2 1. Battery Compartment 1. Battery Compartment 2. LED display 2. LED display HP T1500 UPS INTL HP T1500 UPS JPN/TWN

T1000 G2 and T1500 G2 1. Battery Compartment 1. Battery Compartment 2. LED display 2. LED display HP T1500 UPS INTL HP T1500 UPS JPN/TWN Overview The Tower UPS "G2" models are the next generation HP tower UPSs with USB support. The new models are the UPS T1000 G2, T1500 G2 and R/T2200 G2 respectively. These new UPSs are designed to provide

More information

eserver Integration

eserver Integration 9125 - eserver TOPICS Installation Startup Optional Features Help/Resources 9125 Prep - eserver rev April 01 Page 1 Obtain a copy of Powerware 9125 9910 Installation Guide for IBM Applications and Powerware

More information

IBM xseries tower UPS offers more power, better features, and IBM service and support at a better price

IBM xseries tower UPS offers more power, better features, and IBM service and support at a better price Hardware Announcement September 9, 2003 IBM xseries tower UPS offers more power, better features, and IBM service and support at a better price Overview w you can protect and substantially extend the backup

More information

IBM 7329 Model 308 SLR100 Tape Autoloader Enhances Data Storage

IBM 7329 Model 308 SLR100 Tape Autoloader Enhances Data Storage Hardware Announcement April 23, 2001 IBM 7329 Model 308 SLR100 Tape Autoloader Enhances Data Storage Overview Does your iseries or AS/400 system use QIC Tape Media? Are your save/restore needs expanding?

More information

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting. UPS operation and display panel can rotate 90 degrees, which provides upright viewing for users. Liebert GXT3 UPS Includes These Outstanding Features: Flexibility: Rack/tower configuration. The versatile

More information

IBM Thin Console for System i offers an inexpensive alternative to a twinax-attached system console

IBM Thin Console for System i offers an inexpensive alternative to a twinax-attached system console Hardware Announcement July 11, 2006 IBM Thin Console for System i offers an inexpensive alternative to a twinax-attached system console Overview The 9944 Model 100 IBM Thin Console for System i is a low-cost,

More information

IBM Cluster 1600 and RS/6000 SP Switch2 Features and Adapters Expand IBM s Cluster Technology

IBM Cluster 1600 and RS/6000 SP Switch2 Features and Adapters Expand IBM s Cluster Technology Hardware Announcement November 13, 2001 IBM Cluster 1600 and RS/6000 SP Switch2 Features and Adapters Expand IBM s Cluster Technology Overview The IBM Cluster 1600 extends and enhances IBM s innovative

More information

IBM 42U and 47U 1200mm Deep Static and 42U 1200mm Deep Dynamic Racks for System x

IBM 42U and 47U 1200mm Deep Static and 42U 1200mm Deep Dynamic Racks for System x Announcement ZG10-0303, dated September 7, 2010 IBM 42U and 47U 1200mm Deep Static and 42U 1200mm Deep Dynamic Racks for System x Table of contents 1 Overview 4 Product number 2 Key prerequisites 4 Publications

More information

Eaton UPS. Product Snapshot. Powerware series

Eaton UPS. Product Snapshot. Powerware series Powerware series Eaton 9170+ UPS Features N+X redundancy for both power and logic eliminates systemlevel single point-of-failure Easily scalable to adapt to changing IT environments by simply adding power

More information

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications AC Power For Business-Critical Continuity Liebert GXT3, 5kVA-10kVA UPS Systems: Big Protection, Small Package Today

More information

IBM TotalStorage 3953 Library Manager Model L05 and Tape Frame Model F05

IBM TotalStorage 3953 Library Manager Model L05 and Tape Frame Model F05 Hardware Announcement May 10, 2005 IBM TotalStorage 3953 Library Manager Model L05 and Tape Frame Model F05 Overview The IBM TotalStorage 3953 Library Manager Model L05 and Tape Frame Model F05 allow attachment

More information

R/T2000 G2 HP R/T 2200 UPS INTL HP R/T 2200 UPS JPN/TWN

R/T2000 G2 HP R/T 2200 UPS INTL HP R/T 2200 UPS JPN/TWN Overview The R/T 2200 G2 UPS is the next generation HP rack/tower UPS with USB support. This new UPS is designed to provide advanced power protection (or increased uptime and data corruption avoidance)

More information

Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications

Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications Powerware 9125 (9910-E30) UPS Installation Guide for IBM Applications Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF

More information

New IBM SurePOS 700 controller model provides high performance and convertible style

New IBM SurePOS 700 controller model provides high performance and convertible style IBM United States Hardware Announcement 112-098, dated July 31, 2012 New IBM SurePOS 700 controller model provides high performance and convertible style Table of contents 1 Overview 5 Publications 2 Key

More information

9910-UPS Rack Chart Updated March 08

9910-UPS Rack Chart Updated March 08 All devices and UPS in One rack? 7188 or 5889 PDUs? Qty: Zero to Ten es es E30 (No PDU, Fig 6) 2,100W 2U 9910-0243 rack specify code 9910-9860/61 (L6-20) or: 9910-2975 (L6-30) E30 Options: 9910-6644 2U

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems S5K Modular Series Uninterruptible Power Systems (UPS) This easily upgraded and flexible UPS provides the protection you want, when you need it. The 5K Modular is scalable from 4 to 20 kva, offering many

More information

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments Powerware 9140 Uninterruptible Power System Product Focus Superior de-centralized power protection for medium- and high-density rack environments Product Snapshot Power Rating: Nominal Input Voltage: Nominal

More information

SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch

SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch MODEL NUMBER: SU20KRT-1TF Highlights 20kVA / 20,000VA / 18,000W on-line double-conversion

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems S5K Modular Series On-Line Uninterruptible Power s (UPS) This easily upgraded and flexible UPS provides the protection you want, when you need it. The 5K Modular is scalable from 4 to 20 kva, offering

More information

Selected IBM System p servers offer new optional cryptographic coprocessor and other new functions

Selected IBM System p servers offer new optional cryptographic coprocessor and other new functions Hardware Announcement July 25, 2006 Selected IBM System p servers offer new optional cryptographic coprocessor and other new functions Overview The PCI-X Cryptographic (#4764) for selected System p servers

More information

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Back-UPS RS APC Back-UPS RS 800VA 120V Black Back-UPS RS APC Back-UPS RS 800VA 120V Black APC Back-UPS RS, 540 Watts / 800 VA,Input 120V / Output 120V Includes: CD with software, Cord management straps, Free trial of anti-virus : firewall : email

More information

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU16000RT4U Description Tripp Lite 16kVA SmartOnline

More information

IBM TotalStorage 3581 Tape Autoloader new options for HVEC support Ultrium 3 Tape Drives

IBM TotalStorage 3581 Tape Autoloader new options for HVEC support Ultrium 3 Tape Drives Hardware Announcement April 19, 2005 IBM TotalStorage 3581 Tape Autoloader new options for HVEC support Ultrium 3 Tape Drives Overview New options are being announced in HVEC for the IBM TotalStorage 3581

More information

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview Overview HP Basic PDUs are designed to provide reliable and cost effective power distribution for your HP and non-hp IT racks. Offering simple 0U and 1U installation options, HP Basic PDUs are available

More information

5125 Family Uninterruptible Power System

5125 Family Uninterruptible Power System Powerware series 5125 Family Uninterruptible Power System 5125 rackmount 5000 to 6000 VA Features Protects connected from common power anomalies including surges, sags, brownouts, and over-voltage Provides

More information

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT30KX Highlights On-line double-conversion topology, VFI operation

More information

CTO Configuration Guide

CTO Configuration Guide CTO Configuration Guide FER5GDE October 208 Table of Contents Eaton Ferrups Ferrups 60Hz RM Series Ferrups CTO Worksheet..2 Ferrups 60Hz Rackmount Series Quick Reference Sheet.. 3 Ferrups CTO Details FES.4kVA...4k-

More information

Uninterruptible Power Systems

Uninterruptible Power Systems Uninterruptible Power s 2 S5K Modular Series On-Line Uninterruptible Power s (UPS) The 5K Modular is scalable from 4 to 20 kva, offering many flexible options by adding a few standard modules. Designed

More information

Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection

Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection Liebert GXT4 UPS, 5kVA-10kVA Systems: Best Protection for Critical Network Applications Today s converged networks require increased availability

More information

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR MODEL NUMBER: SU3000RTXL2U Highlights Zero transfer time between AC power and battery

More information

IBM System p5 560Q boosts performance with new Quad-Core Module with 1.8 GHz POWER5+ processor

IBM System p5 560Q boosts performance with new Quad-Core Module with 1.8 GHz POWER5+ processor IBM United States Announcement 107-099, dated February 14, 2007 IBM System p5 560Q boosts performance with new Quad-Core Module with 1.8 GHz POWER5+ processor Description...2 Publications... 4 Services...4

More information

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR700U Highlights 700VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to

More information

ECO Series 120V 850VA 425W Energy-Saving Standby UPS with USB, LCD Display and 12 Outlets

ECO Series 120V 850VA 425W Energy-Saving Standby UPS with USB, LCD Display and 12 Outlets ECO Series 120V 850VA 425W Energy-Saving Standby UPS with USB, LCD Display and 12 Outlets MODEL NUMBER: ECO850LCD Highlights 850VA ultra-compact 120V standby UPS, LCD status and control display Maintains

More information

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets MODEL NUMBER: SMART1500LCD Highlights Supports a half-load (450W) up to 11.8 min. during power outage

More information

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out SmartOnline 200-240V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA)

More information

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR750U Highlights 750VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to

More information

Eaton BladeUPS 12 60kW

Eaton BladeUPS 12 60kW Power Quality Solution for Data Centres Eaton BladeUPS 12 60kW The power quality solution that simply grows with your needs Delivering power reducing costs Two key trends have emerged in the data centre:

More information

New Cisco MDS 9020 Fabric Switch offers 4, 2 and 1 Gbps Fibre Channel switch connectivity

New Cisco MDS 9020 Fabric Switch offers 4, 2 and 1 Gbps Fibre Channel switch connectivity Hardware Announcement October 25, 2005 New Cisco MDS 9020 Fabric Switch offers 4, 2 and 1 Gbps Fibre Channel switch connectivity Overview The Cisco MDS 9000 family, resold by IBM, introduces the Cisco

More information

SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets

SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets MODEL NUMBER: SU20KRT-1TF Description Tripp Lite SU20KRT-1TF 20,000VA / 20kVA / 18,000 watt

More information

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial MODEL NUMBER: SU3000RTXL3UHV Highlights 3000VA / 3kVA / 2400 watt on-line double-conversion

More information

SmartOnline V 12kVA 10.8kW Double-Conversion UPS, N+1, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire

SmartOnline V 12kVA 10.8kW Double-Conversion UPS, N+1, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire SmartOnline 200-240V 12kVA 10.8kW Double-Conversion UPS, N+1, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire MODEL NUMBER: SU12KRT4UHW Highlights 12kVA / 12,000VA / 10,800 watt on-line

More information

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models. Overview. Retired

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models. Overview. Retired Overview The Tower UPS "G2" models are the next generation HP tower UPSs with USB support. These new UPSs are designed to provide advanced power protection (or increased uptime and data corruption avoidance)

More information

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output APC Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232,

More information

IBM Enterprise Rack and Expansion Rack support IBM BladeCenter and IBM System x servers

IBM Enterprise Rack and Expansion Rack support IBM BladeCenter and IBM System x servers , dated July 22, 2008 IBM Enterprise Rack and Expansion Rack support IBM BladeCenter and IBM System x servers Table of contents 1 Key prerequisites 3 Publications 2 Planned availability date 4 Technical

More information

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output APC Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232,

More information

IBM United States Hardware Announcement , dated December 18, 2012

IBM United States Hardware Announcement , dated December 18, 2012 IBM United States Hardware Announcement 112-227, dated December 18, 2012 IBM Half-High LTO Generation 6 SAS Tape Drive offers a reliable, economical, and versatile tape backup subsystem with removable

More information

Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications

Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF

More information

TAA-Compliant OmniVS 120V 1000VA 500W Line-Interactive UPS, Tower, USB port

TAA-Compliant OmniVS 120V 1000VA 500W Line-Interactive UPS, Tower, USB port TAA-Compliant OmniVS 120V 1000VA 500W Line-Interactive UPS, Tower, USB port MODEL NUMBER: OMNIVS1000TAA Highlights Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases 1000VA / 1kVA

More information

TAA-Compliant AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

TAA-Compliant AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port TAA-Compliant AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR750UTAA Description Tripp Lite's AVR750UTAA Ultra-Compact Line Interactive UPS offers complete

More information

TAA SmartPro 208/120V 5kVA 4kW Line- Interactive Sine Wave UPS, 6U, Extended Run, Network Card Options, USB, DB9

TAA SmartPro 208/120V 5kVA 4kW Line- Interactive Sine Wave UPS, 6U, Extended Run, Network Card Options, USB, DB9 TAA SmartPro 208/120V 5kVA 4kW Line- Interactive Sine Wave UPS, 6U, Extended Run, Network Card Options, USB, DB9 MODEL NUMBER: SM5000RT3UTAA Highlights Federal Trade Agreements Act / TAA Compliant for

More information

IBM AIXlink/X.25 V2.1 offers enhancements for migration from X.25 specific adapters that allow APIs to remain the same

IBM AIXlink/X.25 V2.1 offers enhancements for migration from X.25 specific adapters that allow APIs to remain the same Software Announcement July 13, 2004 IBM AIXlink/X.25 V2.1 offers enhancements for migration from X.25 specific adapters that allow APIs to remain the same Overview The AIXlink/X.25 V2.1 program is enhanced

More information

9910-UPS Rack Chart (IEC309 16A) power cord

9910-UPS Rack Chart (IEC309 16A) power cord All devices and UPS in One rack? Zero to Two* or Two or Four** 7188 PDUs? Yes No No One 5161 PDU? (Figure 2) 9910-UPS Chart No Go to Tower UPS Charts or Contact Eaton (Powerware) +44 add number here i5

More information

Powerware 9125 (9910-E64) UPS Installation Guide for IBM Applications

Powerware 9125 (9910-E64) UPS Installation Guide for IBM Applications Powerware 9125 (9910-E64) UPS Installation Guide for IBM Applications Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF

More information

BC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets

BC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets BC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets MODEL NUMBER: BCPRO1400 Highlights 1400VA / 1.4kVA tower 120V standby UPS Maintains AC output during power failures USB port, Front panel

More information

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA) SmartOnline 6U rack/tower UPS 3 phase, 4-Wire + Ground,

More information

Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB

Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB MODEL NUMBER: INTERNET550U Highlights 550VA ultra-compact 120V standby UPS Maintains AC output during power failures 4 UPS battery

More information

IBM expands multiprotocol storage offerings with new products from Cisco Systems

IBM expands multiprotocol storage offerings with new products from Cisco Systems Hardware Announcement July 15, 2003 IBM expands multiprotocol storage offerings with new products from Cisco Systems Overview The Cisco MDS 9000 family is designed for investment protection, flexibility,

More information

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch MODEL NUMBER: SU8000RT4U Description Tripp Lite 8kVA SmartOnline

More information

QuickSpecs HP T750 UPS. Overview

QuickSpecs HP T750 UPS. Overview Overview Rated at 750 VA/500 Watts, the features a unique design and easy-to-configure front panel display. Ideal for desktop, workstation, or entry-level server environments, this Uninterruptible Power

More information

Eaton 5125 UPS family

Eaton 5125 UPS family Powerware series Eaton 5125 UPS family 5125 tower model 1000 to 2200 VA 5125 rackmount 5000 to 6000 VA Features Protects connected equipment from common power anomalies including surges, sags, brownouts,

More information

Model #: SU5000RT4UHV

Model #: SU5000RT4UHV Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SU5000RT4UHV SmartOnline E-series UPS System - High efficiency, On-line, double-conversion

More information

IBM 7014 racks help organize smaller rack-mount systems and expansion drawers

IBM 7014 racks help organize smaller rack-mount systems and expansion drawers Hardware Announcement October 4, 2005 IBM 7014 racks help organize smaller rack-mount systems and expansion drawers Overview Manufactured to meet the EIA 310-D standard, the IBM 7014 Model S11 Rack and

More information