Modern Switching Installations Efficiently Fitted, and Wired Securely

Size: px
Start display at page:

Download "Modern Switching Installations Efficiently Fitted, and Wired Securely"

Transcription

1 Modern Switching Installations Efficiently Fitted, and Wired Securely The complete range of contac tors, efficient motorstarters and variable speed drives for the motor circuit. New simple to install solutions based on clever communication. Technical Essay Dipl.-Ing. Wolfgang Esser Contactors DIL Motor-protective circuit-breakers PKZ Motor-starters MSC Softstarters DS/DM Frequency inverters DF/DV Rapid Link

2 Overview of Contents and Preface Page Contents and preface Overview 2 xstart modern switching installations 2 efficently fitted, and wired securely Excerpt from the system 3 Summary for readers in a hurry Brief description 4 Differentiation between switching installations Switching installation types 5 Volume applications in the lower rating range Distribution of motor ratings 6 xstart the 45 mm engineering dimension continues to advance Width standardisation expanded 6 xstart a contribution towards interface optimisation Compatibility with electronics 8 xstart connection made to measure Termination technology 8 Rationalisation potential in power distribution Evolutionary stages of 8 for relatively large groups of operating media power distribution Busbar systems efficient power distribution Busbar systems 9 with added value in centralised switching installations busbar adapters Changes in systems building brought about by Advantages of decentralisation 10 the trend towards decentralisation Three-phase commoning links and mounting rail adapters efficient Three-phase commoning links, 10 power distribution for relatively small groups of switching devices mounting rail adapters Rapid Link the decentralised switching installation System Rapid Link 12 Systematic connection = tool-less plug connection Tool-less plug connection 13 Ready-for-connection starter combinations Reversing and star-delta starters 15 Switching and protecting motors using UL 508 Type F motor-starters Self-Protected 16 to North American directives for worldwide application Combination Motor Controllers The smallest switching installation motor-protective circuit-breaker PKZM motor-protective 19 in a surface mounting enclosure circuit-breakers Handy motor-starter selection aid The selection slide 20 Validity Status of development 21 and of the Standards The type-tested system of switching installations specifically for the panel builder 22 Literature Further information 23 Modern Switching Installations Efficiently Fitted, and Wired Securely At the Hannover Fair 2004, and also at the Light & Building exhibition in Frankfurt, Moeller presented its new motorstarter system, xstart (Figure 1), for rated currents up to 170A [1]. At both these venues, the company also introduced the new switching cabinet system, xenergy [2, 3]. The two systems optimally complement one another. Switching and protective devices are means to an end. In the final analysis, they are intended for the implementation of power distribution or automation applications for machines or systems. Switching devices, in the style that is normal for the application in question, must also always be housed in the proper way. Power distribution systems in switching cabinets provide the essential main current connections to the switchgear. Moeller intends to work even closer together with its system builder partners in the future, in order to hand over to them even more of the implementation tasks. It was logical therefore to make the two product systems compatible and design them in a way that would make their application childs play for existing and new partners alike, by ensuring that all the components could be safely, reliably, quickly and efficiently combined with one another. This article aims to focus particularly on how the xstart switching and protective devices contribute to rational engineering work. 2

3 57 NO 65 NC Excerpt from the System View without PKZM 4 and contactors up to 150A. For the complete range, see the current Main Catalogue. Auxiliary and main current connections up to 12A, either with screw terminals or spring-loaded terminals Contactors Contactor up to 12 A Contactor up to 32 A Suppressor circuit Motorentstörglied Side-mounted auxiliary contact Top-mounted auxiliary contact Electronic Timer Contactor up to 65 A Contactor up to 150 A Side-mounted auxiliary contact Top mounted auxiliary contact Overload Relays Overload relay up to 32 A Overload relay up to 65 A Overload relay up to 150 A For separate mounting Motor-Protective Switches Motor-Protective Switch with rotary actuation Motor-Protective Switch with pushbutton actuation Current limiter module Shunt- and undervoltage releases Trip-indicating auxiliary contact Side-mounted auxiliary contact Front auxiliary contact Early-make auxiliary contact Door-coupling rotary handle and extension shaft Early-make auxiliary contact Insulated flush mounting enclosure Insulated surface mounting enclosure with Emergency-Stop pushbutton Starter Electrical link Mechanical link Combination plug-in connector Motorstarter with combination plug-in technology Clip plate Busbar adapter Top-hat rail adapter SmartWire module Range (s) Time Figure 1: This diagrammatic representation shows the main components of the xstart product system and how they fit together. 3

4 Summary for Readers in a Hurry The article briefly describes various types of switching installation and their specific requirements for switching and protective devices to be fitted. The remainder of the article deals chiefly with the advantages that the new product system, xstart, brings for engineering and device assembly. The components of the xstart system switch and protect operating media up to 170A, in this way covering the current range of equipment for the potentially most numerous applications for power distribution and automation in machine and system building. Beyond this, for the higher current ranges, the fully compatible NZM circuit-breakers and large DIL M contactors are available. These devices were developed in the last three to four years and were equipped with progressive properties that make them suitable for worldmarkets [4 to 6]. In addition to the advantages of the xstart components by reduction in mounting width and in heat dissipation, specific benefits can also be achieved by selecting the optimum power distribution system for the switching installation in question. Depending on the current ratings involved, these can be busbar systems or compact three-phase commoning links. The critical magnitude of the current to be taken into account Figure 2: Example of a totally insulated distribution board (Protection Class II), ideal for installation ajacent to operating media in demanding environments. in this, may also depend on whether centralised or decentralised switching installations are to be created. Moeller is introducing the fully modular system, Rapid Link, as a particularly advantageous concept for decentralised systems. Outstanding operational benefits for system building result from the timesavings and error reduction achieved by applying the new tool-less plug connection technology, by using busbar or mounting rail adapters and by the availability of ready-for-connection switchgear combinations. All the components introduced are suitable for use the world over and have the required approvals. The special requirements and solutions for motorstarters for the North American market are described, and that the motorstarters designed for the North American market are also suitable for use worldwide. The solutions presented meet the expectations of many machine equipment producers for a switching installation concept comprising a minimum of country-specific variants. All the switchgear presented is housed in the new enclosures from the xenergy range, which are normal and optimal for the application in question. As an alternative to the Protection Class I enclosures, for systems with protective earth terminal, Moeller can also supply totally insulated enclosures and distribution boards to Protection Class II (Figure 2). 4

5 Differentiation between switching installations There is a great heterogeneity of demands made on switchgear cabinets and their mounting and wiring systems. There are considerable differences depending on the application purpose of a switching installation, its geometrical size, its current rating and the size of devices to be built in. Roughly, one can distinguish between purely power distribution Figure 3: Example of a typical power distribution installation in sections. they sometimes carry higher operational voltages, higher short-circuit ratings, higher demands of selectivity higher accessibility standards for example by means of withdrawability or using the Arcon arc-fault protection system from Moeller, higher individual ratings of operating media to be supplied, e.g. motor-starters, and for use in the equipment of buildings (Figure 5), with optimisation of modular installation devices (service distribution boards), a less heavy enclosure construction for lower current ratings, optimisation of the design for residential and special purpose buildings, Type tests for type-tested lowvoltage switchgear and controlgear assemblies (TTA), to IEC / EN Verification of short-circuit withstand strength, Verification of overtemperature limit, Verification of protective conductor continuity, Verification of creepage distances and air clearances, Verification of dielectric strength, Verification of mechanical function, Verification of IP degree of protection, and other verifications. Table 1: With the xenergy system, Moeller offers type-tested switching installations that have successfully passed the above type tests, as well as meeting the building instructions (BA) and installation instructions (AWA) for the further equipment by external system builders. Such system builders then rank as responsible manufacturers of switching installations in accordance with IEC/EN [7]. The system builder has to carry out and document routine tests on the completed switching installations. installations (Figure 3) and electrical equipment for machines and systems, i.e. machine and installation control systems including circuit-breakers and protective devices (Figure 4). Among the power distribution systems to DIN EN [7], there are further structural differences between installations for industrial use: Figure 4: Example of a switching installation for the automation of machines and systems, each with a share of the power section and control section. Figure 5: Example of a power distribution installation for supply to the infrastructure and for the automation of building services. as well as more focused national and regional requirements of EVUs 1 and VNBs 2, additional requirements to IEC / EN [8], release for application in locations where laymen have access to the equipment, for switching or for exchange of fuses. Power distribution installations are typically engineered in sections with a relatively high level of standardisation facilitating compliance with TTA 3 or PTTA 4 requirements (Table 1). Often, even in the industrial power distribution boards, there are motorstarter sections and/or smaller panels containing modular rail-mounted devices mixed in. In the motor-starter sections of power distribution installations, one often finds withdrawable modules with one or two drives being supplied from a single module where the packing density is high (MCC 5 distribution boards). In power distribution installations, but also in the electrical equipment for systems in the raw materials industry, one finds ever higher levels of operational voltages (500V, 690V and sometimes 1000V) and an increase in short-circuit ratings to be controlled to up to 150kA. Such trends are also apparent for the small stand-alone power supply on large cargo ships. For such stringent requirements, the xstart system offers motor-protective circuit-breakers that are inherently short-circuit proof 6 up to 150kA, for example. 1 EVU = Electricity supply company 2 VNB = Distribution network operator 3 TTA = Type-Tested Assemblies 4 PTTA = Partially Type-Tested Assemblies 5 MCC = Motor Control Centre 6 Inherently short-circuit proof protective switches have internal resistance (bimetals) of such a magnitude that it protects them from destruction by short-circuit currents (in this case of up to 150kA). 5

6 The efficient NZM circuit-breakers too are designed to withstand such high short-circuits, with a view to future requirements. Increasingly high currents, at present about 2000A to 5000A, must be controlled in wind farms nowadays, and for this application, powerful vacuum contactors with a long electrical service life and open-type IZM circuit-breakers are available. Switching installations involving more control functions (e.g. machine equipment) are normally engineered to individual requirement. There are often specific, safety-related requirements to IEC / EN [9], the directive for the electrical equipment of machines, to be taken into account. With such switching installations, particularly when there are volume orders, additional requirements may arise in terms of the rational handling of components. For series-manufactured machines for stock, for which no specific order exists at the time, components must be as universally applicable as possible to as yet unknown user locations with hard to predict characteristics such as: system type and short-circuit ratings, unknown reliability of power supply, regionally customary fuse systems and problematic logistics for spares, as well as nationally special conditions and approval requirements. Volume applications in the lower rating range Of course, the superlative technical data described are impressive and effective in the market and benefit the image of a manufacturer of switching and protective devices. Moeller covers such spectacular applications very well technically, as well as economically, with its outstanding xstart system, the large DIL contactors, the NZM and IZM circuit-breakers, as well as the high-level switching installations of the MODAN system. The volume business, however, continues to lie in the lower rating range. Figure 6 shows the ratings distribution of three-phase motors produced in Germany, according to production-statistical data issued by the ZVEI 7. Worldwide, the distribution is similar. The statistics on which the data are based covers all motors of 75 kw. 97% of all three-phase motors have a rating of 15 kw. The tool-less plug technology presented in this article, covers the 7.5 kw rating range. Potentially, more than 80% of all motors can be switched and protected using this new technology. xstart the 45 mm engineering dimension continues to advance The application range of the PKZM 0 motor-protective circuit-breakers, only 45 mm in width, has been expanded by 28 % by the xstart system extending the ratings from 25A to 32A. At the same time, the width of the 15kW contactors was reduced by 25 %, from 60mm to 45mm. This means that, at Moeller, all the protective circuit-breakers and contactors for the volume business up to 15kW are now uniformly only 45mm in width. A critical factor for the success of this very effective grid dimension, was the introduction a few years ago, of the one- or two-contact auxiliary contact modules for front mounting to motor-protective circuitbreakers. In this way, six switches with front mounted auxiliary contacts can be fitted into the mounting width of five motor-protective circuit-breakers with side mounted auxiliary contacts. This represents an improvement by 20%. The auxiliary contacts on contactors have been accommodated in a component width of 45mm for some time, but within the xstart system, the rating range of Excerpt from the cumulative distribution of three-phase motor sizes According to ZVEI production statistics 2002 and 2003 Differentiation is frequently made nowadays between centralised and decentralised system concepts. Each makes different demands on the enclosures and the concepts differ in terms of current ratings, as well as the operating media to be provided with power (Table 2). In switching installations for power distribution, as well as those for the electrical equipment of machines, networking tasks occur with increasing frequency these days. However, they differ in their requirement in terms of processing speed and of information data content [10, 11]. Networking is an essential prerequisite for implementation of decentralised system concepts. Cumulative distribution in % IMD-MS / Esser Motor rating in kw Total of all LV three-phase motors < 75 kw = 100 % Figure 6: The distribution, within the total of three-phase motors produced, allows a sufficiently accurate deduction of the ratings-related distribution of the switching and protective devices involved. More accurate analyses of the distribution among motors are possible via production figures of motor-protective devices that give exact current ratings within a range of 0.75kW to 3kW. The ratio between quantitative potential of large motors and small motors is about 1: ZVEI = Trade association for electrical manufacturers in Germany 6

7 Application Options for Power Distribution Systems Depending on size and spatial and functional division of the switching installations System concept Arrangement of power-, switching & protective devices Centralised electrical equipment Decentralised electrical equipment Systems arrangement spatially and functionally all together spatially and / or functionally divided (e.g. load centres) division between loads and operating media Examples: machine equipment equipment for water treatment plant conveyor- or roller based mechanical handling systems Total rating [kw] per mounting location (enclosure) large power requirement, many operating media, individual operating media with particularly high ratings lower power requirement, fewer operating media, possibly dedicated load centres mostly low individual ratings, often many similar operating media Power supply point-to-point feed via cables or busbar systems point-to-point feed via cables or busbar systems line feed via rigid or flexible busbar systems Power distribution system Within individual enclosures busbar systems preferred, sometimes complemented by three-phase commoning links busbar systems preferred, sometimes complemented by three-phase commoning links direct supply to motor-starters, for groups of starters also three-phase commoning links Fitting of motor-starters Up to about 15kW on busbar adapters or mounting rail or mounting rail adapters on busbar adapters or mounting rail or mounting rail adapters on mounting rails or mounting rail adapters Fitting of motor-protective circuit-breakers and circuit-breakers on busbar adapters possible up to 630A, or on mounting or module plates on busbar adapters possible up to 630A, or on mounting or module plates on mounting rails or mounting rail adapters Arrangement of operating, input and indicating devices mounting locations as required for the application mounting locations as required for the application often integrated in the remote enclosure, but frequently additional centralised operating and indicating station Information and signal exchange increasingly via bus systems increasingly via bus systems predominantly via bus systems Special benefits optimum clarity, less expenditure on enclosure optimised expenditure on cabling, greater flexibility for modification high level of standardisation, particularly cost-efficient cabling, great modification flexibility, frequently plug connection technology used for all electrical terminations Table 2: Increasingly, todays debate is about whether to use centralised or decentralised systems. In addition to many system-specific advantages and disadvantages the decision as to which concept to use also influences the application options for the various power distribution systems and mounting systems. 7

8 the 45mm contactors with integrated auxiliary contact in the base unit has been expanded to 15kW as well. This engineering dimension is further supported by the fact that the mechanical interlock between two reversing starters now no longer requires additional mounting width. This means yet another width reduction (by 15%) compared to conventional solutions with reversing starter combinations in this rating range. For the busbar adapters and mounting rail adapters described later, the assertion of this engineering dimension means that the number of necessary variants is reduced to 1 or 2 times 45mm, thereby improving the economic aspect of these systems. The mounting width of contactors with ratings above 38 A was also significantly reduced and matched to the width of protective circuit-breakers. The width saving on contactors up to 72 A is 22%, on contactors up to 170 A it is as much as 25%. The fact that a reduction of heat losses has been achieved at the same time, means that these savings can translate into a higher component packing density. xstart a contribution towards interface optimisation These days, the watchword in automation technology is: functional levels. These are optimally achieved using various electromechanical and electronic switching devices. Figure 7 shows the functional groups and the interfaces that enable communication between them.the new product system, xstart, has particular strengths in the coordination of interfaces between the functional groups. Particularly notable here are the bi-directional optimisation of all the interfaces between electromechanical components and electronic modules [12]: by a remarkable reduction in power consumption and heat losses in the contactor magnet systems, during pick-up as well as sealing operations, by admissible actuating voltage tolerances (compatibility with electronics) far beyond what the Standards specify, Incoming feed Power distribution Input Processing Output Machine System Actuators Process Sensors Man/machine dialogue Power section Figure 7: The electrical equipment of machines and systems can be divided into functional groups whose relative importance depends on the purpose for which the installation is intended. In small objects they can even merge with one another in a small enclosure. In large objects, the enclosures for control section and power section are often separate and frequently also spatially separately located, i.e. either near the operator or near the load. by the now general integration of a suppressor circuit in all DC operated contactors, by excellent fail-safety of the auxiliary contacts. The integration of the suppressor circuits prevents selection and engineering errors and rationalises application. It prevents the destruction of semiconductor outputs by voltage peaks when switching Off inductive loads (e.g. contactor coils). Suppressor circuits are rarely used in AC operated contactors, but plugged in at the front, if necessary. In addition to optimisation of the interfaces between electronic and electromechanical components, the interfaces between the electromechanical components were also improved in terms of easier and less time-consuming fitting, as well as more rational electrical connection. The most important factor in this is the tool-less plug connection technology explained in detail below. In addition to these improvements for assembly work, a further potential for improvement was implemented in the electrical coordination, e.g. for short-circuit behaviour, as well as in the thermal coordination. xstart connection made to measure Anyone working with switchgear looks at the connections first. Our solution avoids wiring errors, prevents unwanted heating of terminals, and of course, saves money by cutting down on wiring time. Figure 8 shows a view of the terminals, in the direction of cable entry. In the box terminal, there is no screw to avoid in the connection space. Box terminals with two separate chambers ensure the necessary connection forces for their whole service life, even if the cables differ by several cross-section sizes. This reliable termination technology is now available throughout on all contactors up to 400A, on PKZM 4 motor-protective circuit-breakers and on all circuit-breakers with terminals. Since the main current wiring with its mostly larger diameters and rigid cables is normally connected first, the front extension of the coil connections (Figure 9) also contributes significantly towards rational wiring and easier testing. Alternatively, for all the control circuit connections and main current connections up to 12A, screwless springloaded terminals are available. These too have separate openings for two cables. Rationalisation potential in power distribution for relatively large groups of operating media This article is mainly concerned with the implementation of the main current supply and the functional group power section. The various functional groups can differ in importance, depending on the purpose of the installation or machinery and, in the simplest case, in a straightforward small switching cabinet, can merge with one another. The type of power distribution to the power outputs, such as the switched motor-starter outgoing circuits in the electrical equipment for a machine, is of paramount importance for the cost 8

9 Contactor relay, Contactor up to 15 A On contactors On contactor relays 1 st conductor 2 nd conductor Figure 8: Superb termination technology. Its value proven for many years on circuit-breakers, large motor-protective circuit-breakers and contactors, it is now also to be found where the ratings are low: the solid box terminal with separate connection spaces for two conductors per connection. This means the same termination technology throughout for contactors up to 400A. structure of the power sections. There is a historical development here, as well as interesting new trends. Both of these are markedly dependent on the magnitude of the currents to be distributed and on the basic topological structure of the electrical equipment. Historically, we are going to leave aside the period of aesthetic flat wiring on marble or Perinax plates, and rather begin with the introduction of the early busbar systems. There were of course, also evolutionary stages in the development of the busbar systems. At Figure 9: Now the coil connections are located at the front of the contactor. Since, therefore, they are no longer obstructed by the often rigid main current cabling, wiring and voltage testing is simpler and takes less time. The second level contains the connections to the integrated auxiliary contact = Main current connections 4 = Auxiliary contact connection 5 = Coil connection = Auxiliary contact connections 5 = Coil connection Contactor up to 38 A first, they were mostly used as junctions for the power distribution to fuse elements that were fixed to mounting plates. The next step was, to mount these fuse elements in rows, like riders, directly on the busbars. Sometime later, came the first fuseless products with instantaneous magnetic trips for system and motor protection. Until then, shortcircuit protection was exclusively handled by fuses. Moeller, with its legendary PKZM motor-protective circuit-breaker, was an important pathfinder of this advantageous fuseless technology. At first, these motor-protective circuitbreakers, and the circuit-breakers for the higher current ratings, as well as the contactors continued to be fixed to a mounting plate in the enclosure. The screw-fixed, or later snap-fastened to mounting rails [13], switching and protective devices, were at first still protected by the busbar-mounted fuses. Improvements to the motor-protective circuit-breakers led to inherently shortcircuit proof protective switches whose internal resistances were able to reduce the short-circuit currents to a level that did not damage the switches. As far as the machine and system building sector was concerned, this developmental step was accompanied by the changeover from large central drives to several individual drives for the main functions of machines and systems (about 1930 brought the introduction of the squirrelcage motor and the first machine tools). Instead of a few powerful switching and 5 4 protective devices, therefore, increasingly, the demand was for a number of smaller units, and more and more inherently short-circuit proof protective switches were used for this. This trend has continued to this day due to the rising tide of automation of many auxiliary drives that mostly have low ratings. Since inherently short-circuit proof protective switches do not need back-up fuses, there was no longer a need for busbar mounted fuses for them. Consequently, the protective switches themselves were mounted via adapters on the busbars. A few years later, the first busbar adapters were modified to accept contactors, and since then, the space for the busbar systems in the switching cabinet could be utilised even more effectively. Busbar systems are used for several functions: power distribution on the one hand, often for several switching cabinets adjacent to one another, and utilisation of the same space as mounting and wiring level for complete fuseless motor-starter combinations on the other hand. What is an additional benefit, the busbars are rendered virtually touchproof by being covered by the busbar adapters. Any uncovered or spare busbars can be protected by push-on insulated profiles that can be cut to length as required. Busbar systems efficient power distribution, with added value in centralised switching installations At Moeller, the bandwidth of busbar rated currents goes up to 6300A. Such high currents are employed in power distribution installations for the power supply to individual distribution sections. Busbar systems for the lower ratings are fitted within the sections. This article describes only busbar systems that are used for example in the electrical equipment of machines and systems, and in addition to their power distribution function, act as carriers of switching devices. It examines the fitting of fuse elements, but here mainly the preferred fuseless busbar equipment with adaptable incoming and outgoing circuit-breakers and with motor-starter combinations.the current ratings of these busbar systems lie mainly between 200A and 630A. Table 3 shows an 9

10 overview of the most frequently used busbar systems in the rating range up to 200 A. The busbar systems described below all belong to the most frequently used group, i.e. the systems with 60mm between busbar centres. The busbar adapters are conveniently equipped in advance, outside the switching cabinet, with protective circuit-breakers and contactors. The adapters, often prewired as motor-starters, are then simply snapped on to the busbar. Nowadays, preparatory to the installation of motorstarters, more busbar systems are fitted into the switchgear cabinet than are needed for purely power distribution purposes. Increasingly also, one finds vertically mounted busbar systems (Figure 10) in switchgear cabinets. The greater length of busbar offers even more economical fitting options. This arrangement is particularly convenient, taking account of the heat rise involved, where many starters with low individual ratings are to be mounted and wired. The great majority of electric motors, as shown in Figure 6, have ratings of below 4kW. The xstart system supports the success of these vertical systems particularly by the width reduction of switching devices, and above all by the simultaneously achieved drastic reduction in the power consumption of the magnet systems. Reduced consumption means lower heat rise and this in turn allows a technically acceptable economical fitting density on these vertical busbars. The new system also allows DC operated contactors to be mounted without space for air circulation between them. The motor incomers in most cases are connected directly or via plug connectors to the contactors, without the need for terminal blocks. The fact that protective conductors and, where necessary, neutral busbars, are in close physical proximity supports this modern termination technology. In addition, the new toolless plug connections and ready-for connection links between protective circuit-breakers and contactors for higher current ratings minimise the fitting and wiring expenditure by offering shortcircuit protected and short-circuit safe connections. Busbar Rated current Busbar adapter Dimension [mm] [A] Figure 10: Motor-starter outgoing section with vertically fitted busbar systems. Examples of non-wired xstart components on 4- and 5-pole busbar systems. Oblong section CU tinned 12 x One version 15 x is suitable 20 x for all busbar 25 x cross-sections 30 x x x x Double T section possible up to 1600 CU tinned or plain Triple T section possible up to 200 CU tinned Table 3: Busbar system characteristics 10

11 Figure 11: The principle of decentralised switching installations: The supply of progressive and complex multi-motor machinery, sometimes involving highly dynamic relationships between the drives, is now carried by a data and a power bus instead of coming from a large central distribution board. The networkable switchgear and controlgear is housed remotely, i.e. local to the motor, in small cabinets. Changes in systems building brought about by the trend towards decentralisation Since the end of the 1990ies, decentralisation of electrical equipment is a clear trend, and is making differing headway depending on the technology and the industry in question. An important aspect in favour of decentralisation is many machine manufacturers wish for machines of modular construction, to have the part of the electrical equipment that belongs to a module spatially combined with it, and ideally for the connections between the modules to be achieved by plug-in links (Figure 11). Another benefit of decentralisation lies in the potential for reduction of cables and conductors compared to those between central switchgear cabinets and the motors. Where frequency inverters are used, long cables can become problematical due to the formation of travelling waves [14]. Decentralisation results in less electrical power being required to supply individual modules. In order to supply the remote modules economically with the reduced currents, there is no longer a need for busbar systems or they can be replaced by the simpler three-phase commoning links described below. Three-phase commoning links and mounting rail adapters efficient power distribution for relatively small groups of switching devices For a small (e.g. remote) switching installation with only a few motorstarters, or where a group of motorstarters is combined using a group current limiter, busbar systems, even with the lowest ratings, are overdimensioned and uneconomical. For such cases, threephase commoning links have been used successfully for many years. Three-phase commoning links are small, mostly fully encapsulated three-phase busbars with current ratings of up to 63A (PKZM 0) or 120A (PKZM 4). These busbars with connection lugs are simply inserted into the incoming terminals of switching devices fitted onto mounting rails, and screwed tight. In other words, with this solution, the switching devices become the carriers of the three-phase commoning links. This type of power distribution was first employed in meter distribution boards in building services installations of which it has now become an unalienable part. At first, these parts were obtained in commercial lengths and cut to requirement using a saw. Three-phase commoning links for motor-protective circuit-breakers and motor-starters are available now as ready-for connection units for two to five 45mm wide switches. These commoning links are also available in a 55mm grid dimension for PKZM 4. Since motor-protective circuit-breakers and miniature circuit-breakers are also used in variants with side mounted auxiliary contact modules, three-phase commoning links are also available to allow for these extra widths (Figure 12). The supply to the commoning links is made via feeder terminal blocks that allow straightforward connection of the cable cross-sections required for 63 A or 128 A. These feeder terminal blocks additionally enable space and device savings in the implementation of special North American directives (Figure 13), as described below. Figure 12: Three-phase commoning links for side-by-side mounted protective switches and their variants. Their phase spacings allow for side mounted accessories such as auxiliary contact and shunt or undervoltage trip modules. Feeder terminal blocks for large cross-sections, as well as touch protection for spare locations are available as accessories. 11

12 Rapid Link the decentralised switching installation Figure 13: A group of PKZM 0 motor-protective circuit-breakers is connected via a three-phase commoning link on the incoming side. The circuit-breakers use a common BK25...-E incoming terminal block that, with increased creepage and clearance distances, meets the requirements of construction to Type E. This solution can also be achieved in the xstart system using PKZM 4 motor-protective circuit-breakers. The three-phase commoning links are touch-protected at the ends, and are available for operational voltages up to 690V with worldwide approval. At first, these busbar elements seem expensive, but they save much preparation and processing time. Their strength lies in the error-free and short-circuit proof connections they produce and in the not inconsiderable contribution they make towards the high-quality appearance of the switching installation. These commoning links are now increasingly being used also in North America. circuit-breaker terminals by moving the lower adapter-mounting rail, or to remove them from the connection. Where only a few mounting rail adapters are required, then they are screwed directly to the mounting plate or several adapters are simply snapped onto a mounting rail. To achieve the necessary rigidity where heavier contactors are involved, the mounting rail adapters are fixed to two mounting rails. An outstanding example of the implementation of all the benefits of decentralised switching installations is the very sucessful Rapid Link system from Moeller. All the switching and protective devices, the relevant part of the switching program, as well as the local signalling and manual switching elements for an individual drive are gathered together in a small insulated enclosure (Figure 15) [15, 16]. In addition to its high degree of protection (IP 65), typical for Rapid Link is the wide range of integrated electronic motor protection that keeps the number of necessary variants to a reasonable level. The system also offers starters for variable speed motors (Speed Control Unit). The metal enclosure base here acts as heat sink. At present, the main applications for starters for motors up to 3kW lie mainly in large-scale mechanical handling systems for warehouse logistics and in baggage handling systems for the most modern airports in the world. However the system promises to conquer other industries too. Rapid Link starters have been accepted into many operating media specifications and into tendering texts of the technology leaders in the mechanical handling industry as the best possible solution.the cabling essentially comprises a power bus for 400V and for 24V, a data bus for the control functions and the feed to the individual motor. The switching devices that are connected using the three-phase commoning links are normally snapped onto mounting rails. Where motor-starters are involved, all the motor-protective circuit-breakers and all the contactors respectively are snapped onto one of two mounting rails arranged one below the other, or mounting rail adapters are used to great advantage (Figure 14). The latter bring the added benefit that components can easily be extracted from a group assembly merely by moving the adapter mounting rail without the complete three-phase commoning link having to be disassembled. It is just as easy to insert the larger contactors with electrical connectors into the motor-protective Figure 14: Mounting rail adapters have two independently movable mounting rails that make insertion and removal of individual components easy without having to disassemble the three-phase commoning link. 12

13 Rapid Link system properties of Rapid Link will certainly achieve the highest possible level of rationalisation of its electrical equipment. Figure 15: The individual enclosures of the decentralised motor-starter system, Rapid Link, are mounted locally to the drives. Electrical power is supplied error-free via a power and a data bus. Connection to the motor in most cases is also via a plug connector. Looped, round-section cables could be used instead of the flat band power cable shown here. The electrical connection technology was designed to allow individual drive modules to be exchanged without interruption of the power and data bus. Flexibility in application, optimised cabling and a particularly high level of accessibility are among the special characteristics of the system. In the ideal case, the cabling is fully pluggable, either using round or flat band cables. The latter can be used with piercing connection elements similar to those used first with the AS-Interface bus. The Disconnect Control Unit is the main and maintenance switch, as well as cable protection in one. In addition, this unit can be used to implement remote Emergency-Stop concepts. The Interface Control Unit represents the interface to the open fieldbus. The Motor Control Unit functions as direct-on line or reversing starter with electronic motor protection from 0.09 to 3kW. The drive specific settings are made simply via AS-Interface or DIP switches. Optionally, there is a Logic Control Unit that can be used as application oriented local small control unit where autonomous preprocessing of the I/O signals is required, for example for actuation of accumulating conveyors. A superordinate control system merely tells the Unit how the goods are to be transported. In addition, the integrated display shows the operating states as plain text messages. xstart components are also integrated into the Rapid Link system. Any application that can be implemented using the described Additional front plug sockets for tool-less plug-in technology Systematic connection = tool-less plug connection Manual work represents a potential weakness in a control system. It is also highly expensive. The time taken is difficult to calculate and often there are bottlenecks regarding suitable personnel. Where manual work is done under time pressure, errors creep in easily. All these are reasons for seeking practical compromise solutions between manual fitting and automation. There are many repetitive actions involved in control system building. This is where the idea of the tool-less plug-in technology comes in: on each motor-starter, the connection must be made between motor-protective circuit-breaker and contactor. On reversing starters, in addition, the reversing wiring to the second contactor for the main and control circuits must be put in place. Where these links are made using wires the regulations covering operating media specify in many cases that both ends of the connection must be labelled, not to mention the ferrules. PKZM 0 motor-protective circuit-breaker with rotary actuation,up to 16 A DIL A contactor relays, DIL M contactors up to 15 A Figure 16: Connections for the tool-less plug-in technology on PKZM 0 motor-protective circuit-breakers with rotary actuation, for currents up to 16 A, as well as on DIL A contactor relays and DIL M contactors up to 15 A 13

14 a visible isolating gap. The user can choose between connection sets for the assembly of standard motor-protective circuit-breakers with standard contactors (PKZM0-XD M12 or PKZM0-XR M12), or, for the most popular control voltages, 230V50HZ / 240V60HZ and 24 VDC, he can have ready assembled and mounted MSC-D- direct-on-line starters or MSC-R- reversing starters supplied ex-factory. Figure 17: Tool-less plug-in connection technology on a direct-on-line starter with the advantages of secure fixing on just one carrier rail and positive and error-free connection between motor-protective circuit-breaker and contactor. The physical volume of the mechanical link is used for ancillary functions of the tool-less plug-in connection technology in a further development stage of the system. This is mindless work, on which expensive, specialised personnel are wasted. Up to 15 A, PKZM 0 motor-protective circuit-breakers with rotary actuation, and contactors in the xstart system generally have additional oblong plug sockets on the front (Figure 16). 15 A at 400V equates roughly to 7.5 kw, a rating that is higher than that of most motors in today s automation technology. On the contactors, even the built-in auxiliary contact modules and coil connections are equipped with the plug connections. Here for example, the reversing interlock in the control circuit is simply plugged in. High-quality springy plug-in lugs ensure reliable electrical connection. The plug connectors reliably cope with the entire current and voltage spectrum, from control circuit connections in the ma range with low control voltages, up to motor currents of 15 A and voltages up to 415 V. The new tool-less plug-in connection technology was developed jointly with the world market leader in electrical plug connectors. motor-protective circuit-breakers and contactors to produce stable assemblies that can be securely snap-fitted on to just one top-hat rail. When the plug connector is pulled out, there remains The contactor apertures for the toolless plug-in connectors, as shown in Figure 16, are also suitable for accepting reversing or star-delta bridges. Furthermore, the apertures of the toolless plug connectors are used for solder pin adapters. Using the solder pin adapter (Figure 18), it is simply possible to plug on circuit boards with direct contact to the main circuit connections and the contactor coil connections, on contactors or reversing contactor combinations. The customer can mount electronic components on these circuit boards for their own applications such as additional functions for delay circuits, pulse circuits or customized networking tasks (keywords: alternative printable contactor combinations). Further modular components that also have plug connections to the contactor Figure 17 shows the tool-less plug-in connection technology by the example of a direct-on-line starter up to 12A. Mechanical plug modules connect Figure 18: The new tool-less plug-in connection technology enables pcb s to be plugged on to switchgear to connect directly with the terminals. The user can design the layout of the printed circuit board and equip it as required. 14

15 Thermistor-protective module based on tool-less plug-in technology coils are fitted onto the contactors (Figure 19) and/or the main circuit connections. In this form motor filters for contactors up to15 A or electronic timing relays simply need to be plugged onto the contactors. In addition, it is possible for feedback to be monitored via auxiliary contact modules, or to build in especially dustproofed, highly fail-safe auxiliary contacts for extra low currents and voltages. The tool-less plug connections thus open up a whole new range of applications for the future. External 24V DC auxiliary voltage Motor with built-in thermistor sensor Figure 19: An enclosure that is plugged onto the contactor and mechanically latched with it, can accommodate standard circuits from the catalogue or customised circuits. These, e.g. an electronic timing relay, are then in direct contact with the coil connections and so enable the switchgear to be monitored if required. The combinations using the tool-less plug-in connection technology are only 45mm or 90mm wide and can be employed to great advantage fitted on busbar adapters. For a sufficient, continuous and defined demand, it will be possible to supply these starters fitted on busbar adapters, ready for connection. Ready-for-connection starter combinations One of the main purposes of lowvoltage switchgear is the switching and protection of motors. In fact, this is the task of motor-starters, and these are available in a wide variety of versions for standard applications. A number of different technical levels offer from manually operated starters via current and voltage limited solutions to the frequency inverters for variable motor speeds. What is common to most solutions is that they combine several components for the necessary switching and protective functions. Selection of the components is made easier by the selection aids described later. Here, the emphasis is on optimisation of error-free fitting and wiring. Standard, universally applicable components are combined in each case. These standard components are produced in large quantities and therefore offer high, constant quality at favourable prices. The main current bridges, DILM12- XSL or DILM12-XRL, for the contactors <15 A, are inserted into the sockets of the tool-less plug connectors (Figure 20) quickly and in a space-saving manner. The new reversing and star-delta main current bridges for contactors above 15 A and <32 A (DILM32-XRL and DILM32- XSL), have been made significantly more compact (Figures 21, 22) and now also fit between contactors and motor-protective relays. The system allows a flexible modularity while offering a dependable fixed mounting dimension using standard contactors and motor-protective circuitbreakers. It reduces the costs for fitting and testing, and it increases the serviceability of installations by the facility for rapid exchange of components. The tool-less plug-in connection technology, what is more, does not limit the ways in which components have always been customarily handled / fitted. The system interfaces on contactors and motor-protective circuit-breakers cost the same. New costs only arise from using the cost-efficient plug connectors. But these costs are more than compensated for by the systematic savings described. Figure 20: Ready-for-connection fitted and wired switchgear assemblies from the xstart system cut the time needed for fitting and testing. 15

16 Figure 21: Reversing contactor combination for current ratings of 17A, 25A or 32A with integrated-ball mechanical interlock that requires no extra space. a) M32XP2 paralleling bridge, b) M32XR reversing bridge a) b) and machine manufacturers. The reason was that in North America additional short-circuit protective elements are mandatory, which are not specified by the electrical Standards in the rest of the world. Additional protective devices require extra space in the switchgear cabinet, as well as added coordination, and must be included in the documentation. Taking into account the different switching installation layouts, they result in the manufacture of an undesirable number of system variants. As far as conformance to the Standard is concerned, there are now helpful new layout solutions for motorstarters that support the European type motor-protective circuit-breakers and now enable a uniform cabinet layout for North America and the IEC world. However, alongside these improvements described below, there are still special requirements to be taken into account by exporters to North America, such as mandatory approval of all components and systems, and wiring using AWG cables. The time saving using these prepared bridges in comparison to individual wires should not be underestimated. The contactors are mechanically linked to form a unit using DILM32-XVB or DILM150-XVB clips. The user can fit and wire all the combinations either by using the mounting and wiring aids offered by Moeller, or by his own preferred method. Particular time-savings can be had by employing combinations already preassembled, ready for connection, as well as functionally tested in Moeller s own workshops. For a sufficient, continuous and defined requirement, customer-specific combinations can also be built. In order to avoid having to deal with quantities of waste from the packaging of individual assemblies for customised solutions that are often needed in large quantities, it makes sense to supply these in volume packaging rather than individually wrapped. Switching and protecting motors using UL 508 Type F motor-starters to North American directives for worldwide application (Self-Protected Combination Motor Controllers) In the past, the export of switching installations to North America often brought nasty surprises for the installation In the USA and Canada a distinction is made, as shown in Table 4, between distribution equipment and devices for the switching of industrial loads, i.e. industrial control equipment. Separate Standards apply to these two types of equipment, also making differing demands on it. Above all, the specifications for creepage and clearance distances in air and for a) c) b) Figure 22: Star-delta combinations for 15kW to 30kW / 400V with new, particularly space-saving main current bridges. a) M32XP2 paralleling bridge, b) M32XR delta bridge = reversing bridge, c) M32XS1 star-point bridge 16

17 switching capacity are more stringent for power distribution equipment. Motor-protective circuit-breakers of any manufacture are classified, developed, tested and approved to UL 508 and CSA-C22.2 No.14 [17]. In North America, the following four basic functions are mandatory for all remotely switched motor circuits: Isolating (main switch) Short-circuit protection Operational switching (contactor) Overload protection The critical difference between this and the international classification is that in America, the motor-protective circuitbreakers marketed in Europe, such as PKZM or comparable devices, can only fulfil the overload protective function as Manual Motor Controllers. Switching devices of this construction are not recognised, in their basic form, as short-circuit protective elements. This classification is not due to any failed tests, but rather to the fact that as a matter of principle, the American Standards have for many years demanded separate upstream shortcircuit protective elements with wider creepage and clearance distances. European motor-starters that combine all the functions/devices for short-circuit protection, overload protection and operational motor switching (e.g. circuitbreaker + contactor + overcurrent relay), are classified as Combination Motor Starters. A supplement within Standards UL 508 and CSA-C22.2 No. 14, has broadened the classification Combination Motor Controller by Construction Type E. The relevant addendum demands a higher short-circuit switching capacity and compliance with the wider creepage and clearance distances in air specified in UL 489 and CSA-C22.2 No [18] on the incoming side of the switch, in order to enable omission of an additional upstream short-circuit protective element (Figure 23). Product Groupings in North America Components for energy distribution (Distribution Equipment) e. g. UL 489, UL 98, UL 248 and CSA-C22.2 No. 4, CSA-C22.2 No. 5-02, CSA-C22.2 No. 248 Molded Case Circuit Breakers (UL 489) Molded Case Switches (UL 489) Safety switches (UL 98) Fusible Disconnect Switches (UL 98) Fuses (UL 248) UL CSA UL 98 CSA-C22.2 No. 4 UL 248 CSA-C22.2 No. 248 Special requirements: These devices need to be particularly robust in their construction and feature larger electrical spacings than standard equipment: (for V: 1 Inch through air, 2 Inches over surface). Lower permissible temperature rise (50 C). Product design more divergent than IEC equivalent. Incoming and outgoing feeder components for energy distribution assemblies (Switchgear, Switchboards, Panelboards) must conform to these standards. Main disconnect and protective switches used in industrial control assemblies must also conform to these standards. Safety testing for these products maintain strict standards and factory production quality is closely monitored by inspectors from each approval authority. Quarterly and extensive re-examination testing as a function of production. UL/CSA Molded Case Circuit Breaker testing standards are amongst the most stringent in the industry worldwide. Components for motor control (Industrial Control Equipment) UL 508, UL and CSA-C22.2 No.14 Magnetic controllers (contactors) Control Relay Overload Relays Manual Motor Controllers (protectors) Rotary Cam Switches Pushbuttons and Pilot Switches Solid State controls and systems Programmable Controllers Special requirements: These components are smaller in size and electrical clearances are not as large as those of energy distribution equipment. Industrial control devices are installed primarily in control panels, in motor branch and associated load circuits, in Motor Control Centers (MCC) and also as components in some energy distribution assemblies. They can be combined in the same circuit as energy distribution equipment in control panels, e.g. with a circuit breaker used as a main disconnect and protective switch in a motor branch circuit. Factory production is also monitored by the approval authorities, but not to the same extent as applies to circuit breakers. Generally speaking, more compatible with conventional IEC-designs. Table 4: Differentiation between device types in North America and alignment to the North American directives, UL 508 and CSA-C22.2 No.14 [17], or UL 489 and CSA-C22.2 No [18]. UL... designates the USA, CSA... the Canadian directives. UL 98 = [19], UL = [20] 17

18 Upstream protective device UL 508 Type E Type E - devices fulfil all four functions (isolating, shortcircuit protection, overload protection, operational switching), therefore the upstream protective device can be omitted. Figure 23: UL 508 Type E devices to UL / CSA directives, due to their enhanced creepage and clearance distances on the incoming side of the motor-protective circuit-breaker and their high switching capacity, provide all four functions of a motor-starter, and the upstream protective device therefore, can be omitted. Type E devices are designated in North America as Self-Protected Motor Starters. The described manual UL 508 Type E protective devices, e.g. PKZM0-.. with BK25-..-E incoming feeder terminal, are merely an interim solution for the export problem. As a rule with machine equipment, motors are to be switched automatically using contactors. This is where the next expansion of the directive helps out. Manual UL 508 Type E starters become UL 508 Type F Combination Starters (Figure 24) by combination with contactors. As shown in Figure 25, Type F Combination Starters also need no series protective device. It must be noted that Type F starters, like Type E starters, must be used only in earthed mains systems (e.g. 480Y/277 V). UL 508 Type F starters are at present available only for the USA, because Canada has not yet adopted the changed directive. The PKZM 0 and PKZM 4 motorprotective circuit-breakers enable interesting implementation possibilities as UL 508 Type E starters within the xstart system. In modular systems, PKZM 0 or PKZM 4 together with the three-phase commoning links described and special BK25...-E or BK50/3-PKZ4-E feeder terminal blocks (Figure 13) can be used. These feeder blocks are decisive for Type E approval. But they must have the enhanced creepage and clearance distances to UL 489. The fact that the three-phase commoning links are permitted, is a welcome additional benefit. Since they allow several motorprotective circuit-breakers to be supplied on the incoming side via three-phase commoning links, these solutions enable economical and space-saving control system layouts as they are customary in the IEC world. It is the new, now slightly bigger feeder terminal block that makes the difference to the previous international solution, and can now be used in all switching installations worldwide. It must be noted that UL 508 Type E starters must be used only in earthed mains systems (e.g. 480Y/277 V). The utilisation of UL 508 Type E starters brings the following benefits: because no such element needs to be built into the system additionally, space saving in terms of device fitting, No wiring between additional components, Lower equipment cost and therefore overall cost of the switching installation, A rapprochement to the control system construction usual in the IEC world. A purely modular system, where the manufacturer or the builder of the switching installation combines approved modules at his own responsibility, does not exist in North America. Only combinations that are named in the Moeller Approvals files are acceptable. In the Approvals files, Moeller has included all the admissible or sensible combinations that produce Type-starters. All the three-phase commoning links already had UL and CSA approvals. Simplified engineering, since there is no need for coordination with an (often unknown) external upstream short-circuit protective element, and Figure 24: Example of UL 508 Type F Combination Starter combined from manually operated UL 508 Type E devices and contactors. The combinations have to be listed in switchgear manufacturer s Approvals files. 18

19 Upstream protective element UL 508 Type F Type F -devices are combinations of Manual Type E devices and additional contactors. Here too, the series element can be omitted. Type F -Geräte 1 = (Manual) Type E device 2 = Contactor 1 = (Manual) Type E -Gerät Figure 25: Type F Combination Starters provide all four functions of a motor-starter to UL 508, the upstream protective device can be omitted here as well therefore. When selecting combinations, it makes sense to consult the current selection lists from manufacturers, since these are constantly developing and at times offer considerable technical and economic benefits. Detailed information regarding the difficult topic of Motor-starters for utilisation in North America is offered in another article [21]. The smallest switching installation motor-protective circuit-breaker in a surface mounting enclosure Among the most versatile switching and protective devices are the motorprotective circuit-breakers.they are in themselves already complete motorstarters and represent the first choice for many applications not involving very frequent or remote switching. Characteristics that make motor-protective circuit-breakers into universal switching and protective devices Basic properties of PKZM 0 and PKZM 4 motor-protective circuit-breakers: Circuit-breakers optimised for motor protection, Operational switching by hand, Clear indication of the switch position, Current-dependent, inherent short-circuit protection possible up to 150kA, At higher rated currents, application oriented short-circuit protection up to 50kA at 400V or group protection for several breakers, Usable up to 690V, Personnel protection through all-pole de-energization and quick tripping, Fixed, simultaneous short-circuit protection for cables and operating media, Adjustable overload protection for cables and operating media, Suitable for rated currents up to 65A, i.e. for 90 % of all three-phase motors, Equally suited to the switching and protection of resistive loads, Their phase-failure sensitivity makes them suitable for the protection of EEx e motors, with approval to ATEX 100a [22], Short recovery time after fault removal, Suitable for world markets, with all the necessary approvals and acceptances, Optional functions of PKZM 0 and PKZM 4 motor-protective circuit-breakers: Mounting and encapsulation with high degree of protection, Occasional remote tripping, Protection by undervoltage trips against automatic restart, Usable as main switch or Emergency-Stop switch in the main circuit, Isolation of the Emergency-Stop circuit by early-make auxiliary contacts, Versatile locking facilities, Multiple, differential status indication, even a networkable solution, Comprehensive system accessories. Table 5: Motor-protective circuit-breakers become universal switching and protective devices due to their design characteristics. 19

20 open, in an insulated surface mounting enclosure with high degree of protection, or fitted on the proven flush mounting plate for mounting in the machine or instrument enclosure (Figure 27). Handy motor-starter selection aid Figure 26: Shown middle and left are motor-protective circuit-breakers PKZM 4 and PKZM 0 with rotary drives, on the right the new PKZM 01 with pushbutton actuation. All the many functions are combined in the smallest of spaces in a single device as shown in Table 5. Motor-protective circuit-breakers are small circuit-breakers developed and tested to the Standard IEC / EN [23] and the motorstarter Directive IEC / EN [24]. The isolating characteristics comply with IEC / EN [25]. The PKZM is synonymous in the market with the term motor-protective circuitbreaker. PKZM motor-protective circuitbreakers in decentralised electrical systems are increasingly used as main or Emergency-Stop switches in the main current circuit. Breakers with rotary drives offer benefits for use inside the switching cabinet (Figure 26, middle and left), with their ratings now expanded up to 65A. The typical door-coupling rotary handles with or without door interlocking are designed for this type of fitting. Extension shafts with centring guides facilitate adaptation to various cabinet depths. (Figure 26, right). In an emergency, the breaker can thus be simply knocked out. Many users want the pushbutton actuation because they do not regard toggle or rocker actuations as equivalent. In addition to the rotary operation, Moeller is therefore bringing back the classical push actuation in the shape of the PKZM 01 for currents up to 16A, complete with mushroom button for Emergency-Stop actuation on simple machines. PKZM can be used either Complementary to the comprehensive selection pages in the Moeller Main Catalogue, Moeller also offers a PC-based electronic selection program for motorstarters. In addition to the different operational voltages, short-circuit ratings and types of coordination [24], it takes into account fuseless as well as fused combinations. Moeller offers this little program free of charge on the Internet ( For the practician, there is also the well-known and popular selection slide card that has been issued for many years now. It guides you to the correct device dimensions with short-circuit coordination to types 1 or 2, via the required operational voltage and the motor rating, without the need for a PC (Figure 28). In addition, it shows standard cable cross-sections and admissible cable lengths to achieve Standard-compliant tripping of the protective elements, and how they can be adapted as required for the installation conditions on site. The selection slide can be provided with several different slide inserts giving the figures for direct-on line and reversing starters, as well as star-delta starters. Within the new xstart product system from Moeller, the popular pushbutton actuation was being reintroduced. When the switch is fitted directly to simple machines, actuation by pushbutton is the most ergonomic and efficient Figure 27: The smallest, complete switching installations: fitted into surface mounting enclosures, with or without mushroom actuator for Emergency-Stop, or PKZM 01 fitted directly into the machine enclosure on a flush mounting plate. 20

21 Validity This article sets out the status of development and of international Standards, as at June Changes cannot be excluded. The most up-todate statements of fact are always to be found in the current catalogues of the Moeller GmbH, Bonn. Here you will also find detailed data regarding motorstarters for various types of coordination and voltages to IEC/EN [24]. Approvals and acceptances had been sought when this article went into print. Figure 28: The selection slide from Moeller is a simple tool that enables various types of motorstarter to be dimensioned taking into account type 1 or 2 short-circuit coordination as required. The free of charge selection slide is available on request from Moeller. In addition, electronic selection, configuration and engineering tools are available, which support the construction of switching installations consisting of xenergy enclosures and mounting systems, as well as their equipment with Moeller switching and protective devices. The xenergy system includes prepared circuit-breaker module sets, for example, including the necessary cross members and front plates. xenergy also uses the 17.5 mm depth dimension familiar from the NZM circuit-breakers, which enables breakers of differing sizes to be installed with a common front. The optimised use of xstart switching devices is also being prepared. 21

22 SmartWire connecting motor starters instead of wiring Up to now motor starters were elaborately connected to the I/O cards of PLCs. SmartWire enables switching devices to be connected to a PLC without any complex control circuit wiring necessary. The control circuit wiring between the PLC and the switching devices is completely replaced by pluggable, pre-assembled connection cables. In this way up to 16 motor starters can be connected to the PLC XI/ON Substitution of control wiring Up to now the motor starter for control and feedback of the switching states had to connected to the PLC in a time consuming process using individual cables. This process is both time and resource consuming. The number of required connections increases the possibility of an error in every phase. The connection of the motor starter with SmartWire on the other hand, offers a very simple and clear solution. In order to make a motor starter SmartWire-compatible, the user simply plugs an additional SmartWire module onto the contactor. This module provides a six-pole plug connector that replaces the control circuit connections. The SmartWire cables are then just simply plugged together. 1 easynet/canopen gateway 2 PROFIBUS DP gateway 3 Modbus gateway 4 XI/ON gateway with SmartWire interface slice 1) 5 SmartWire interface slice for X20 system 2) 6 I/O module Direct-on-line-starter MSC-D up to 32 A 8 Direct-on-line-starter MSC-D up to 15.5 A 9 Power module 10 Connection cable 11 SWIRE-DIL contactor module 12 Star-delta starter MSC-R up to 12 A Der SmartWire Systembaukasten zur Verbindung von Motorstartern und Schützen Eliminating the PLC I/O level The control circuit wiring is eliminated not only on the switching devices but also on the PLC. This also saves the costs for I/O modules which are now no longer required. Wherever compact design is called for, the space saved provides options for effective control cabinet design. The connection of the motor starter to the PLC is implemented via a gateway. Gateways are available for PROFIBUS DP, easynet, CANopen and Modbus. Furthermore, the SmartWire modules can be connected directly to the automation systems from Micro Innovation and B&R. Standard switchgear SmartWire is an addition to the tried and tested Moeller range of switching devices and is designed as an accessory for standard devices. The flexibility of all switching devices is fully retained since even existing system accessories can still be used. The use of standard devices means that inventory costs are not unnecessarily increased and the worldwide availability of spare parts is ensured. Advantages at a glance: Substitution of control wiring Substitution of the PLC I/O level High level of flexibility by the use of standard xstart series devices Reduction of the engineering and documentation costs due to elimination of terminals Reduction of the commissioning costs by avoiding wiring faults Reduction of stock-keeping costs through the use of standard devices 1) Product available from Micro Innovation GmbH. Information available at com 2) Product available from B&R Industrie-Elektronik Ges.m.b.H. Information available at com 22

Solid-State Switching Devices

Solid-State Switching Devices Overview 3RF21 3RF20 3RF22 3RF23 SIRIUS 3RF2 solid-state switching devices Solid-state switching devices for resistive loads Solid-state relays Solid-state contactors Function modules Solid-state switching

More information

The simplicity of it! Tool-less plug connection without tools!

The simplicity of it! Tool-less plug connection without tools! The simplicity of it! Tool-less plug connection without tools! Using the new xstart motor-starter combinations it is possible to create the best solutions from standard products even more easily and efficiently.

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

Solid-State Switching Devices

Solid-State Switching Devices Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

Innovations in the Sirius Modular System for greater efficiency in Industrial Controls and in control cabinet construction

Innovations in the Sirius Modular System for greater efficiency in Industrial Controls and in control cabinet construction Eckard Eberle, Head of the Control Components Business Segment Siemens AG, Nuremberg International Trade Press Conference held on 24 November 2009 in Nuremberg Innovations in the Sirius Modular System

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

Safe Isolation of Main Circuits with Switch-Disconnectors N or with Molded Case Switches NS

Safe Isolation of Main Circuits with Switch-Disconnectors N or with Molded Case Switches NS www.moeller.net Safe Isolation of Main Circuits with Switch-Disconnectors N or with Molded Case Switches NS Reliably and safely controlling, switching and managing power. In industry, in buildings and

More information

System solutions for your energy requirements

System solutions for your energy requirements System solutions for your energy requirements Power distribution from the smallest to the largest The tried-and-tested, highly fl exible power distribution system for individual requirements. From small

More information

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS. 3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA

More information

Go to:

Go to: System PKZ 0 ectors 08/019 Clip plate Standard version Short version C-PKZ0 072900 C-PKZ0-K 206740 One of the clip plates is always necessary when combining a PKZM0 manual motor prr and a S(E)00 magnetic

More information

Miniature circuit breakers for all applications

Miniature circuit breakers for all applications Miniature circuit breakers for all applications BETA Low-Voltage Circuit Protection Answers for infrastructure. BETA Low-Voltage Circuit Protection: Circuits under Control, Wherever, Whenever. Whether

More information

3RT, 3TB, 3TF Contactors for Switching Motors

3RT, 3TB, 3TF Contactors for Switching Motors RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor

More information

CLIPLINE complete. The modular terminal block system for all applications

CLIPLINE complete. The modular terminal block system for all applications CLIPLINE complete The modular terminal block system for all applications CLIPLINE complete All connection technologies, one system With CLIPLINE complete, the unique modular terminal block system from

More information

Reliable Switchgear from One Proven Supplier

Reliable Switchgear from One Proven Supplier Catalogue Industrial Switchgear 2007/2008 Reliable Switchgear from One Proven Supplier Xtra Combinations Xtra Combinations from Moeller offers a range of products and services, enabling the best possible

More information

Load Feeders, Motor Starters and Soft Starters

Load Feeders, Motor Starters and Soft Starters Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

for a perfect electrical installation. The range of rail-mounted terminal blocks

for a perfect electrical installation. The range of rail-mounted terminal blocks The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry. For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.

More information

RiLine Compact The smart power distribution system

RiLine Compact The smart power distribution system RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Series CA7 Contactors

Series CA7 Contactors Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Rotary switches T and switchdisconnectors. reliable switching, disconnection, control and operation

Rotary switches T and switchdisconnectors. reliable switching, disconnection, control and operation Rotary switches T and switchdisconnectors P for safe and reliable switching, disconnection, control and operation The high-performance, robust and compact rotary switches T and switchdisconnectors P are

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

UL 489 DIN rail branch circuit breakers

UL 489 DIN rail branch circuit breakers UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product

More information

pointofsale available at your local trade outlet

pointofsale available at your local trade outlet pointofsale available at your local trade outlet pointofsale products IP65 pushbuttons Ø22.5mm Contact rating @ 240V AC 10A Resistive (AC1), 6A (AC15) PB01C PB02C PB03C PB04C PB05C PB06C PB07C PB08C PB09C

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED SIGUARD Safety Combinations and Safe Load Feeders safety INTEGRATED EMERGENCY Topmost priority protection of man, machine and the environment The topmost priority is to protect man, machine and the environment

More information

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...

More information

SIMOCODE 3UF Motor Management and Control Devices

SIMOCODE 3UF Motor Management and Control Devices Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

Module 18plus. Description. 18plus

Module 18plus. Description. 18plus Module 8plus Description Wiring of load and signal lines in a space-saving manner will become ever more important for designers of electrical plants and systems, because all control cabinets and control

More information

Switch cabinet housings. Distribution housings. Appropriate housings for each application. Our experience. Your safety.

Switch cabinet housings. Distribution housings. Appropriate housings for each application. Our experience. Your safety. Switch cabinet housings Distribution housings Appropriate housings for each application Our experience. Your safety. Overview of the housing ranges Mounting rail bus system In-Rail Bus...6 Switch cabinet

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Mirror Contacts for Highly-Reliable Information Relating to Safety-Related Control Functions

Mirror Contacts for Highly-Reliable Information Relating to Safety-Related Control Functions www.moeller.net Mirror Contacts for Highly-Reliable Information Relating to Safety-Related Control Functions The complete range of contactors, efficient motorstarters and controlled drives for the motor

More information

SUNCLIX Connection technology for photovoltaics

SUNCLIX Connection technology for photovoltaics SUNCLIX Connection technology for photovoltaics Connection technology for photovoltaics Are you looking for innovative and reliable connection technology for your PV modules, inverters or the complete

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

The easy way to connect. Product Information. SmartWire-Darwin. The cost-optimised communication system for switchgear

The easy way to connect. Product Information. SmartWire-Darwin. The cost-optimised communication system for switchgear Darwin Technology www.moeller.net/darwin The easy way to connect. Product Information SmartWire-Darwin The cost-optimised communication system for switchgear SmartWire-Darwin. Cost-optimized communication

More information

EasyConnect SmartWire

EasyConnect SmartWire EasyConnect SmartWire Seite - 1 Darwin Evolution in panel building Seite - 2 Darwin Control Drives easyconnect Motor starter MCCB Command and indication Seite - 3 Less wiring by moving the I/O to the contactor

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

MOTUS ContactronControl. Less is more.

MOTUS ContactronControl. Less is more. MOTUS ContactronControl. Less is more. Content. MOTUS Less is more. Less wear, longer lifespan. Learn more about MOTUS at our website. 3 Our Company. Page 4. For more than 80 years, Wöhner has stood for

More information

Metering module NZM-XMC

Metering module NZM-XMC Metering module NZM-XMC Recording and optimising energy Product Information Metering module NZM-XMC Metering and communication module for energy distribution and motor control centres Recording energy

More information

Motor protection circuit breakers

Motor protection circuit breakers Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability

More information

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview Overload Relays Siemens AG 2009 Overview 1 2 2 (1)Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters, these connecting

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery

More information

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry. For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery

More information

SIRCO Load break switches for power distribution from 125 to 5000 A

SIRCO Load break switches for power distribution from 125 to 5000 A The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of

More information

US Catalog July 2016 SMISSLINE TP

US Catalog July 2016 SMISSLINE TP US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information

More information

IEC & 2 standard. The reference for safe and reliable LV switchboards

IEC & 2 standard. The reference for safe and reliable LV switchboards IEC 61439-1 & 2 standard The reference for safe and reliable LV switchboards IEC61439-1 & 2 The power of a standard adapted to your needs IEC standards are today legal or market references. The new IEC

More information

Switching Devices 7/1. 7/4 Product overview. 7/5 5TT5 remote control switches. 7/8 5TT3 0 switching relays. 7/9 5TT5 7 Insta contactors

Switching Devices 7/1. 7/4 Product overview. 7/5 5TT5 remote control switches. 7/8 5TT3 0 switching relays. 7/9 5TT5 7 Insta contactors 7/4 Product overview 7/5 5TT5 remote control switches 7/8 5TT3 0 switching relays 7/9 5TT5 7 Insta contactors 7/10 5TT3 4 Soft-starting devices 7/11 5TT5 2 EMERGENCY-STOP modules 5 7 8 9 10 12 13 7/1 When

More information

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

UL 489 Cable-In / Cable-Out Branch Circuit Breaker Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up

More information

Revolutionizing control wiring

Revolutionizing control wiring SmartWire-DT Panel Wiring Solutions Revolutionizing control wiring 797-6925 Fax: (215) 221-1201 www.royalelectric.com SmartWire-DT Changing the way panels are wired. Reduce cost throughout the value chain.

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

SIRIUS Motor Management and Control Devices

SIRIUS Motor Management and Control Devices Overview is a flexible, modular motor management system for motors with constant speeds in the low-voltage performance range. It optimizes the connection between the control system and motor starter, increases

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 454 PHOENIX CONTACT and feed-through terminal blocks The more varied the tasks in electrical engineering, the more varied the components for the solution have to be. The industrial connection technology

More information

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety MEDIUM VOLTAGE PRODUCTS UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety 2 UNISEC AIR-INSULATED MEDIUM VOLTAGE SECONDARY DISTRIBUTION SWITCHGEAR Operator

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

New Products Catalogue SmartWire-Darwin. The easy way to connect. The easy way to connect.

New Products Catalogue SmartWire-Darwin. The easy way to connect. The easy way to connect. Darwin Technology www.moeller.net New Products Catalogue 2009 The easy way to connect. The easy way to connect. . Evolution in the control panel. Controlling Manufacturers of machines and systems strive

More information

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators SmartWire-DT In panel and on machine wiring solutions Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators SmartWire-DT Changing the way panels... Reduce cost throughout

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers .2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60 DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North

More information

Application Techniques CENTERLINE 2100 Motor Control Centers

Application Techniques CENTERLINE 2100 Motor Control Centers POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product

More information

Industrial Controls. Protection Devices. Gerätehandbuch. Answers for industry. Edition 09/2014

Industrial Controls. Protection Devices. Gerätehandbuch. Answers for industry. Edition 09/2014 Industrial Controls Protection Devices SIRIUS Innovations - Thermal Overload Relays SIRIUS 3RU2 / Solid-State Overload Relays SIRIUS 3RB3 Gerätehandbuch Manual Edition 09/2014 Answers for industry. SIRIUS

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

Solutions from Lean Connectivity to Lean Automation. The easy way to connect. Cost Optimization Clever Communication

Solutions from Lean Connectivity to Lean Automation. The easy way to connect. Cost Optimization Clever Communication Solutions from Lean Connectivity to Lean Automation The easy way to connect. Cost Optimization Clever Communication SmartWire-DT. From Lean Connectivity to Lean Automation. Controlling Lean Connectivity

More information

Technical Guide. Safety Applications. For Immediate Delivery call KMParts.com at (866) Building Automation. Industrial Automation

Technical Guide. Safety Applications. For Immediate Delivery call KMParts.com at (866) Building Automation. Industrial Automation tra Combinations Building Automation Industrial Automation Systems Technical Guide Safety Applications Ulrich Trapp Bildgrösse 0 x 118,5 mm 2 Logo 17 x 17 mm Think future. Switch to green. Risk assessment

More information

Requirements for machine approval in North America under the new NEC 2017

Requirements for machine approval in North America under the new NEC 2017 Requirements for machine approval in North America under the new NEC 2017 2 Rittal NEC 2017 The NEC 2017 introduces increased requirements for SCCR Rittal has long been prepared Rittal always responds

More information

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

Your requirements for drive controllers and regulators are the driving force behind our connection technology Let s connect.

Your requirements for drive controllers and regulators are the driving force behind our connection technology Let s connect. Your requirements for drive controllers and regulators are the driving force behind our connection technology Let s connect. OMNIMATE Device Connectivity Perfect-fit connectivity solutions for drive controllers

More information

Connection System SmartWire Module

Connection System SmartWire Module Connection System SmartWire Module Hardware and Function Description 11/06 AWB1210+1251-1591GB AWe keep power under control. All brand and product names are trademarks or registered trademarks of the owner

More information

Surface-Mounting Product Ranges

Surface-Mounting Product Ranges Introduction Overview Light signals SCHUKO socket outlets Two-circuit switches Garages, laundry rooms, laboratories and workshops are often exposed to a lot of heavy-duty activity, which includes the odd

More information

Miniature Circuit Breakers for Railway Applications

Miniature Circuit Breakers for Railway Applications Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent

More information

48 Series 4C Series 58 Series Relay Interface Modules 15.8 mm wide Relay Interface Modules 15.8 mm wide

48 Series 4C Series 58 Series Relay Interface Modules 15.8 mm wide Relay Interface Modules 15.8 mm wide The FINDER Relay Interface Module ADVANTAGE Take advantage of a pre-assembled unit and make your job easier One Part Number combines relay, socket, clip and LED/suppression module UL listed devices with

More information

Electrical Connection Technology. New Items: Autumn 2007

Electrical Connection Technology. New Items: Autumn 2007 Electrical Connection Technology New s: Autumn 2007 Contents Rail-Mounted Terminal Block Systems Volume 1 02 57 PCB Terminal Blocks and Connectors Volume 2 58 91 WINSTA WINSTA 93 97 Index of Nos. 98 102

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

Simply on. Simply off. Day and Night. sirius SWITCHING

Simply on. Simply off. Day and Night. sirius SWITCHING Simply on. Simply off. Day and Night. sirius SWITCHING SIRIUS-Funktionen im Überblick Switching Protecting Starting Monitoring and controlling Detecting Commanding and signaling Supplying Engineering SIRIUS

More information