Switching Devices 7/1. 7/4 Product overview. 7/5 5TT5 remote control switches. 7/8 5TT3 0 switching relays. 7/9 5TT5 7 Insta contactors
|
|
- Dominic Watts
- 5 years ago
- Views:
Transcription
1 7/4 Product overview 7/5 5TT5 remote control switches 7/8 5TT3 0 switching relays 7/9 5TT5 7 Insta contactors 7/10 5TT3 4 Soft-starting devices 7/11 5TT5 2 EMERGENCY-STOP modules /1
2 When things start hotting up: Electrical switching takes place every time a control system assumes control or automatic functions. Remote control switches for pulse control or Insta contactors switch the loads. The range of different demands ask for a broad spectrum of different contacts and rated currents. 6/2 7/2
3 Everything runs automatically. 7 BETA Electrical Switching 7/3
4 Product overview Overview Devices Application Standards Usage Non-res. buildings Res. buildings Industry Remote-control switches without central switching Switching of lighting by pushbutton DIN EN (VDE 0637) with central switching DIN EN (VDE 0632) with central and group switching Blind and series remote-control switch Electronic series remote-control switch Flush-mounting remote-control switches System remote-control switches without central switching with central switching with central and group switching Relays for PLCs Switching of small loads or application DIN EN (VDE 0435) in controllers for capacitive loads Specially suited for the switching of luminaires such as fluorescent lamps or high-pressure and metal-halide lamps, with capacitive properties Insta contactors Switching of motors, heating or lighting, such as fluorescent lamps or filament lamps, and resistive and inductive loads EN , EN , EN Soft-starting devices 5TT3 441, 230 V AC 5TT3 440, 400 V AC Protection of machines with transmission, belt or chain drives, conveyor (VDE 0660 Part 117) DIN EN , belts, fans, pumps, compressors, packing machines, door operating mechanisms Definitions I e = Rated operational current U e = Rated operational voltage I c = Rated control supply current U c = Rated control supply voltage P s = Rated operational capacity 1 MW = 18 mm modular width N-type EMERGENCY-STOP modules 5TT5 200, 10 A Electrical switching Uniform mounting depth Fitted with a transparent cap, these devices have the same uniform mounting depth valid for all products. EMERGENCY-STOP switching of machines in industrial, commercial and private economic applications acc. to the EC directive for machines 98/37/EG, DIN EN There are a number of general operational demands, particularly with regard to the switching of lighting, that need to be taken into consideration during planning. The technical background represented here is for illustration and clarification purposes and is intended to help you avoid planning errors and prevent the time and hassle caused by premature failures. 7/4 Siemens ET B1 2005
5 1 Overview 5TT5 remote-control switches 2 Remote-control switches 5TT5 5 5TT5 15 Blind and series remote control switches Electronic series remote control switches Flush-mounting remote control switches System remotecontrol switches 5TT5 16 5TT TT TT5 60 5TT5 61 5TT5 62 Manual operation Switch position indication Fuse protected against continuous voltage For different phases between magnet Yes, 5TT5 15 No no no no yes coil and terminals for central and group input Operating noises Standard quiet very quiet quiet very quiet Short-circuit strength up to 800 A Siemens ET B /5
6 5TT5 remote-control switches Selection and ordering data Version U e I e U c MW Order No. Price PG Weight PS*/ 1 item 1 item P. unit V AC A AC V AC V DC kg Items Remote-control switches with transparent cap Contact gap 3 mm, short-circuit strength up to 800 A 1 NO contacts TT / TT / TT / TT / TT / TT /12 5TT NO contacts TT / TT / TT / TT / TT / TT /12 1 CO contact TT / TT / TT / TT / TT /12 5TT5 150 with central switching, contact gap 3 mm, short-circuit strength up to 800 A 1 CO contact TT /12 2 NO contacts TT /12 3 NO contacts TT /6 with central and group switching, µ-contact, very quiet operation 1 NO contacts TT TT NO contacts TT TT Remote-control switches without transparent cap Contact gap 3 mm, short-circuit strength up to 800 A 3 NO contacts TT / TT / TT / TT /6 5TT5 503 Blind remote-control switch with transparent cap Contact sequence , contact gap 3 mm 2 NO contacts TT TT5 163 Series remote-control switches with transparent cap Contact sequence , contact gap 3 mm 2 NO contacts TT TT TT TT /6 Siemens ET B * You can order this quantity or a multiple thereof.
7 Selection and ordering data 5TT TT TT TT TG TG TG TT5 remote-control switches Version U e I e U c MW Order No. Price PG Weight PS*/ 1 item P. unit V AC A AC V AC V DC 1 item kg Items Electronic series remote-control switch with transparent cap Contact sequence , µ-contacts 2 NO contacts TT Remote-control system switches with transparent cap µ-contact, very quiet operation 1 NO contact TT TT TT with 2 switching systems 1 NO contact per switching system with central switching TT TT TT NO contact TT with central switching, with 2 switching systems 1 NO contact per switching system TT with central switching, with 3 switching systems 1 NO contact per switching system TT with central switching, with 3 switching systems 1 NO contact per switching system TT with central and group switching with transparent cap 1 NO contact TT with central and group switching, with 3 switching systems 1 NO contact per switching system Compensator, mounting depth 55 mm TT PTC resistor combination for increasing glow lamp loads Transparent caps TG Spare part for devices with an overall width of 1 MW 5TT5 5. Only for devices with an overall width of 1 MW. 1 set (1 set = 5 items) 1 5TG set Spare part for devices with an overall width of 1 MW 5TT3 0., 5TT3 1, 5TT3 4., 5TT5 1. and 5TT5 6. For devices with an overall width of 2 MW 5TT5 1. you need 2 transparent caps. 1 set (1 set = 5 items) 1 5TG set Spare part for devices with an overall width of 2 MW 5TT3 4., 5TT5 6. and 5TT set (1 set = 5 items) 2 5TG set * You can order this quantity or a multiple thereof. Siemens ET B /7
8 5TT3 0 switching relays Selection and ordering data 5TT TT3 061 Version U e I e U c MW Order No. Price PG Weight 1item PS*/ P. unit V AC A AC V AC V DC 1 item kg Items Switching relay with transparent cap 1) 1 NO contact TT TT TT TT TT NO contacts TT TT TT TT TT CO contact TT TT TT TT TT CO contacts TT TT TT for control with direct voltage 110 5TT TT CO contacts TT TT for switching capacitive loads; of lighting 30 5TT TT NO contact TT for control of PLCs Contact: 15 to 60 V, 2 to 30 ma according to EN , type 1 1 NO contact TT Sealable enable relay, mounting depth 55 mm Used for boiler/storage relays. In the case of continuous duty, a distance of 1 MW must be maintained between the devices. 1 CO contact TT TT ) For spare transparent caps see page 7/7. 7/8 Siemens ET B * You can order this quantity or a multiple thereof.
9 Selection and ordering data 5TT TT TT TT TT5 7 Insta contactors Version U e I e U c MW Order No. Price PG Weight 1item Insta contactor PS*/ P. unit V AC A AC V AC V DC 1 item kg Items for alternating current continuous operation, with switch position indication, with alternating current magnet system 2 NO contacts TT TT NO contact, 1 NC contact TT TT NC contacts TT TT for AC or DC continuous operation, with switch position indication, with DC magnet system 4 NO contacts TT TT TT NO contacts, TT NC contact TT NO contacts, TT NC contacts TT NC contacts TT TT NO contacts TT TT NO contacts, ) TT NC contact TT NO contacts, ) TT NC contacts TT NO contacts TT TT NO contacts, ) TT NC contact TT NO contacts, ) TT NC contacts TT Auxiliary switch for left-sided mounting on the 24-A, 40-A and 63-A Insta contactor; max. one auxiliary switch per Insta contactor. Minimum contact load 24 V AC; 5 ma 2 NO contacts 230, AC TT NO contact, 1 NC contact 230, AC TT Spacer for heat conduction between the Insta contactors. We recommend placing a spacer between each second Insta contactor. Can be mounted reciprocally, so that two spacers enable greater cable penetration 0.5 5TG TG TT ) For NC contacts 30 A. Sealable terminal covers 1 set for Insta contactor 24 A, (1 set = 2 items) 2 5TT set 1 set for Insta contactors 40 A and 63 A, (1 set = 2 items) 3 5TT set * You can order this quantity or a multiple thereof. Siemens ET B /9
10 5TT3 4 soft-starting devices Overview 1-phase 1.5 kw 3-phase 5.5 kw Increases the service life of one-phase asynchronous motors and mechanical drive equipment Can also be retrofitted in existing systems Separate setting of acceleration time and starting torque With LED display for startup or continuous operation The power semiconductors are bridged after completion of startup. Selection and ordering data Version U e P c MW Order No. Price PG Weight 1item PS*/ P. unit V AC W 1 item kg Items Soft-starting device with transparent cap 1) 1-phase TT L1 N AI2_ TT3 441 t acc M st T1 T2 t acc : Acceleration time M st : Starting torque Soft-starting device, mounting depth 55 mm 3-phase, 2-phase motor actuation TT L3 L2 L1 AI2_ TT3 440 t acc M st T3 T2 T1 t acc : Acceleration time M st : Starting torque 1) For spare transparent caps see page 7/7. 7/10 Siemens ET B * You can order this quantity or a multiple thereof.
11 Overview Scope The scope of the EC Directive Machines is no longer restricted to industrial machinery, but now covers virtually all machines for use in all areas of commercial and private trade and industry and applies to all Stationary Movable, Hand-held, Mobile Machine tools and processing machines Prime movers and production machines Risk analysis and selection of a suitable category Engineers and operators assume responsibility for the correct risk assessment. It is difficult to make a quantitative assessment of the risk, so that when selecting the category, the reasonable risk can be determined within a broad band width. Risk parameter S: seriousness of injury minor injury serious and irreversible injury of one or several persons or death of a person Benefits Acc. to the 98/37/EC EC directive for machines Safety category 4 acc. to DIN EN Acc. to the 98/37/EC EC directive for machines Selection and ordering data Risk parameter F: Risk parameter P: frequency and possibility of duration avoiding injuries rarely to frequently frequently to constantly possible under certain circumstances hardly possible possible under certain circumstances hardly possible 5TT5 2 EMERGENCY-STOP modules Compressors Operating and packaging machines Machines in underground mining Earthmoving machines and harvesters Hoisting equipment Floor conveyors Machines for lifting persons Plants Interchangeable equipment, such as snow ploughs and mountable sweeping devices This becomes clear if you select "F2 - frequently to continuous" instead of "F1 - rarely to frequently", for the risk parameters "F - Frequency and duration" when drawing up a risk graph (see image). The whole band width of safety categories may lie between the assessment of "often" and "frequently". Categories B Safety category 4 acc. to DIN EN Electrical isolation between electric circuit and control LED display for operation and circuit state I2_08404a preferred categories for reference points possible category which requires additional measures with regard to the risk overdimensioned measures with regard to the risk Version U e I e U c MW Order No. Price PG Weight 1item PS*/ P. unit V AC A V AC 1 item kg Items EMERGENCY-STOP module, mounting depth 55 mm TT TT5 200 * You can order this quantity or a multiple thereof. Siemens ET B /11
12 Notes 7/12 Siemens ET B1 2005
Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationSENTRON SIVACON ALPHA
SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 10/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution
More informationMiniature Circuit Breakers for Railway Applications
Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent
More informationPLC. Module 3: Hardware and Terminology. IAT Curriculum Unit PREPARED BY. Jan 2010
PLC Module 3: Hardware and Terminology PREPARED BY IAT Curriculum Unit Jan 2010 Institute of Applied Technology, 2010 ATE321 PLC Module 3: Hardware and Terminology Module Objectives Upon successful completion
More informationFan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in prom design. It is intended for installation in the distribution board on 35 mm mounting rails.
More informationOvervoltage Protection Devices
Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12
More informationATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase
Characteristics variable speed drive ATV310-3 kw - 4 hp - 380...460 V - 3 phase Complementary Product destination Main Range of product Altivar Easy 310 Product or component type Product specific application
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationALPHA SIMBOX Small Distribution Boards
ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional
More informationSolid-State Contactors
Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing
More informationQUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12
operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even
More informationContact protection relay
Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts
More informationPLC Fundamentals. Module 2: Hardware and Terminology. Academic Services Unit PREPARED BY. August 2011
PLC Fundamentals Module 2: Hardware and Terminology PREPARED BY Academic Services Unit August 2011 Applied Technology High Schools, 2011 ATE1212 PLC Fundamentals Module 2: Hardware and Terminology Module
More informationSafety Systems Safety Integrated
3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored
More information3RA13, 3RA14 Contactor Assemblies
RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock
More informationVARIABLE SPEED DRIVES
VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES 0.4...30kW THREE-PHASE COMPACT, VERSATILE HIGH PERFORMANCE Automatic car washing equipment APPLICA TION AREAS Packaging Automatic and semi-automatic packaging
More informationSafety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E
EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0
More informationATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate
Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - on base plate Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011
Technical data 2CDC508136D0202 ABB i-bus KNX Product description The device is a modular installation device (MDRC) in Pro M design. It is intended for installation in distribution boards on 35 mm mounting
More informationATV12H018M2 variable speed drive ATV kW hp V - 1ph
Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 200..240V - 1ph Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationVARIABLE SPEED DRIVES
VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES 0.4...110kW THREE-PHASE COMPACT, VERSATILE HIGH PERFORMANCE Automatic car washing equipment APPLICA TION AREAS Packaging Automatic and semi-automatic packaging
More informationATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)
Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product
More information5SL Miniature Circuit Breakers
5SL Miniature Circuit Breakers BETA Low-Voltage Circuit Protection The new 5SL miniature circuit breaker is intended for use up to ka. The devices have the system features characteristic of all Siemens
More informationdv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2
dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical
More informationExtension module for lighting control
s 3 842 DESIGO RXC Extension module for lighting control Extension to the RXC30 / RXC31 / RXC38 room controller RXC40.1 RXC40.5 The RXC40 extension module is used in conjunction with an RXC30, RXC31 or
More informationATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)
Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product
More informationABB ABB 143 2CDC110004C0205. Safety relays. C57x and C67xx range. Content
ABB Safety relays C7x and C67xx range Content Selection table... 44 Approvals and marks... 44 Safety for man and machine... 46 General information... 46 Safety category acc. to EN 94-... 47 Standards,
More informationWelcome to the features training module for ACS industrial drive modules.
Welcome to the features training module for ACS880-04 industrial drive modules. 1 ACS880-04 single drive modules are optimized for easy and cost-efficient cabinet assembly. This power intensive drive module
More informationTwo-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems
SR 2ZH A 23 3 3 X S2 S A. K K2 PROTECT SR 2ZH Dimensions Two-hand module to DIN EN 574 (997) type III C Plug-in terminals 2 safety enabling outputs feedback output with NC function (floating contact) Electronic
More informationABB i-bus KNX Fan Coil Actuators FCA/S Product Manual
Fan Coil Actuators FCA/S Product Manual Contents 1 General... 5 1.1 Using the product manual...5 1.1.1 Notes...6 1.2 Product and functional overview...7 1.2.1 Product overview...7 1.2.2 Functional overview...8
More informationATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink
Product datasheet Characteristics ATV12H075M3 variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - with heat sink Complementary Main Range of product Altivar 12 Product or component type Product
More informationABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161
Technical Data 9AKK107045A4913 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
More informationABB i-bus KNX Fan Coil Actuators FCA/S Product Manual
Fan Coil Actuators FCA/S Product Manual Contents 1 General... 5 1.1 Using the product manual...5 1.1.1 Notes...6 1.2 Product and functional overview...7 1.2.1 Product overview...7 1.2.2 Functional overview...8
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)
Product data sheet Characteristics ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW) Complementary Assembly style Function available Power supply voltage limits Main Range of
More informationDatasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10
General Description Room Control Unit RCU Series are designed as an all in one product for different room layouts such as apartments, hotel rooms, hospitals and residences. Available versions of EAE RCU
More information5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009
Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens
More informationPSR UC/ESAM4/3X1/1X2/B
Safety relay for emergency stop and safety door monitoring Data sheet 105318_en_02 PHOENIX CONTACT 2014-06-13 1 Description The safety relay can be used in safety circuits according to EN 60240-1 and IEC
More informationABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011
, 2CDG 110 15x R0011 SA/S 12.6.1.1 2CDC 071 033 S0012 The 6 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are suitable for
More informationVARIABLE SPEED DRIVES
VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES 0.4...75kW THREE-PHASE COMPACT, VERSATILE HIGH PERFORMANCE Automatic car washing equipment APPLICA TION AREAS Packaging Automatic and semi-automatic packaging
More informationABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011
Technical Data 2CDC505054D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.6.2.1, 10 A are modular installation devices in ProM design for installation in the distribution board. They are
More informationET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)
SIMATIC ET 200S distributed I/O SIMATIC Preface ET 200S distributed I/O Digital electronic module 2DO AC24..230V (6ES7132-4FB01-0AB0) Properties 1 Parameters 2 Diagnostics 3 Manual 04/2007 A5E01077264-01
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More informationControl Transformers Control transformers
Control Transformers It is often desirable to operate the control circuit at a lower voltage than the power circuit. Control transformers are used to step a voltage down to a lower level. Siemens Class
More informationATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection
Product datasheet Characteristics ATS22C17Q Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product
More informationATV320U04N4C variable speed drive ATV kW V - 3 phase - compact
Characteristics variable speed drive ATV320-0.37kW - 380...500V - 3 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product
More informationHigh-performance switching actuators
High-performance switching actuators Wide-ranging applications efficient installation and set-up operation for many years The worldwide standard for home and building control siemens.com/gamma Switching
More informationRev Operating Instructions Busch-Dimmer. Potentiometer U-101
1473-1-7906 Rev. 01 17.12.2012 Operating Instructions Busch-Dimmer Potentiometer 2112-101 2112 U-101 Busch-Dimmer 1 Safety... 3 2 Intended use... 3 3 Environment... 3 4 Technical data... 4 5 Setup and
More informationTechnical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n
Safety module CS AT 0 Module for emergency stops, end position monitoring for movable guards with delayed contacts at the opening of the input channels, semiconductor outputs (e.g. light barriers and magnetic
More informationDescription. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00
Monitoring functions Evaluation of brush length monitoring, digital, non-floating Evaluation of brush length monitoring, digital, floating A00 A06 Non-floating brush length monitoring with use of KM01
More informationATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase
Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short
More informationQUINT-BUFFER/24DC/24DC/40
Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1
Product datasheet Characteristics ATV630U15N4 variable speed drive ATV630-1.5kW/2HP - 380...480V - IP21/UL type 1 Main Range of product Product or component type Product specific application Device short
More informationSIGUARD Safety Systems Safety Integrated
SE 10 / SE. 00 / SE. 4 / SE. 5 Molded plastic / metal enclosure with separate actuator Application Safety interlock switches (limit switches) with separate actuator are used where the position of doors,
More informationSR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories
/ SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in
More informationLarge Frame IEC Contactors
Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting
More informationOvervoltage Protection Devices
Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge arresters, type
More informationATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)
Characteristics soft starter-ats22-control 220V-power 230V(15kW)/400...440V(30kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component
More informationSIMOREG 6RA70 DC MASTER SIMOREG CM
SIMOREG RA70 DC MASTER /2 Application /2 Design /3 Technical Data /3 Standards /4 Block diagram / Options Siemens DA 21.1 200 /1 SIMOREG RA70 DC MASTER Application An important application for the converter
More informationATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection
Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product
More informationSafety relays C57x and C67xx range
C7x and C67xx range Content Selection tables... 112 Safety for man and machine, General information... 114 Safety for man and machine, Safety category acc. to EN 94-1... 11 Safety for man and machine,
More informationLabeling accessories Art.-No. suitable. Wiring accessories Art.-No. suitable. Color: blue 10-pole spacing 6.2 mm MIRO 6.2
Labeling accessories suitable ACS label plate KM 5 7000-99001-0000000 Relays, solid state relays, opto-coupler, intelligent interface technology, passive interface technology, eurocard holder, modules
More informationLine reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation
Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal
More informationPSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B
PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B
More informationProduct Family: Electro Mechanical Relays Number: AN-LC-008
APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data
More informationATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)
Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component
More informationOvervoltage Protection Devices
Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type
More informationTSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W
Characteristics Preventa safety module - 24 V DC - standard format - < 5 W Main Range of product Product or component type Complementary [Us] rated supply voltage Supply voltage limits Activation threshold
More informationElectronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data
More informationSolid-State Switching Devices
Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data
More informationBNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS
BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS Safety Controller Suitable for use with Coded-Magnet Sensor Part Numbers below BNS250... BNS33... BNS303...
More informationSINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4
Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical
More informationCrane Control Contactors and Relays
October 8 DC Relays Type KC Heavy-Duty Mill 75 Contact Conversion The fully visible contacts have NEMA ICS--5 heavy-duty interrupting ratings and are easily converted in the field using just a screwdriver
More informationSafety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor
Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor Features M Safety-category 4 acc. to DIN EN954-1 M Stop-category 0 M Crossfault monitoring M Monitored start (On-switch) or automatic start
More informationLatching, Sequence and Impulse Relays Application Data
Latching, Sequence and Impulse Relays Application Data Energy Conservation Relays In many applications it is important for the customer to conserve electrical energy. One approach to energy conservation
More informationATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate
Characteristics variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - on base plate Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW
Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Complementary Assembly style Function available Power supply voltage limits Main Commercial Status Commercialised
More informationATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h
Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart
More informationSwitching module for AC V and up to three load stages, with manual switching
8 149 PTM13-M3 DESIGO I/O modules Switching module for AC 24 250 V and up to three load stages, with manual switching PTM13-M3 Signal converter for connection to P-bus, with three interlocked on/off control
More information3RP, 7PV Timing Relays
3RP, PV Timing Relays Overview Standards The timing relays comply with: EN 6021-3-3 "Environmental conditions" EN 61812-1/DIN VDE 0435 Part 2021 "Solid-state relays, timing relays" EN 61000-6-2 and EN
More informationLightning and Surge Arresters
Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement
More informationATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink
Characteristics variable speed drive ATV12-2.2kW - 3hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationNew Solutions. for AC Motor Starters
ADAPTABILITY RELIABILITY CREATIVITY New Solutions for AC Motor Starters Featuring : Electronic Centrifugal Switches for Capacitor Start (Capacitor Run) Motors / Digital Motor Starters for Three Phase Bidirectional
More informationATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book
Characteristics variable speed drive ATV320-15kW - 380...500V - 3 phase - book Main Range of product Product or component type Product specific application Device short name Format of the control block
More informationATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book
Characteristics variable speed drive ATV320-15kW - 380...500V - 3 phase - book Main range of product product or component type product specific application device short name format of the drive product
More informationATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book
Characteristics variable speed drive ATV320-11kW - 380...500V - 3 phase - book Main range of product product or component type product specific application device short name format of the drive product
More informationATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW
Characteristics soft starter for asynchronous motor - ATSU01-9 A - 200..480V - 1.5..4 KW Complementary Assembly style Function available Power supply voltage limits Main Range of product Product or component
More informationMotor protection circuit breakers
R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,
More informationSED2 Variable Frequency Drives
Building Technologies SED2 Variable Frequency Drives More standard features Means better control of HVAC applications The global leader in Heating, Ventilation and Air Conditioning (HVAC) products and
More information26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.
66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual
More informationDrive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety
Drive Technology \ Drive Automation \ System Integration \ Services Manual Control Cabinet Inverter MOVITRAC B Functional Safety Edition 05/2009 16811216 / EN SEW-EURODRIVE Driving the world Content Content
More informationSAFETY RELAY YRB-4EML-31S MAIN FEATURES
SAFETY RELAY TYPE 4 SAFETY PROTECTION DEVICE FOR SAFETY LIGHT CURTAINS/BARRIERS MAIN FEATURES For safety light curtains and access control barriers, emergency stop, door switch Safety Integrity Level (SIL)
More informationPSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description
SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used
More informationSiemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.
KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More informationActive Front End Drives: Lower Harmonics, Higher Energy Savings
Active Front End Drives: Lower Harmonics, Higher Energy Savings 2 Active Front End Drives: Harmonics Performance Overview 1.0 Evolution of VFDs When variable-frequency drives (VFDs) arrived on the industrial
More information