Switching Devices 7/1. 7/4 Product overview. 7/5 5TT5 remote control switches. 7/8 5TT3 0 switching relays. 7/9 5TT5 7 Insta contactors

Size: px
Start display at page:

Download "Switching Devices 7/1. 7/4 Product overview. 7/5 5TT5 remote control switches. 7/8 5TT3 0 switching relays. 7/9 5TT5 7 Insta contactors"

Transcription

1 7/4 Product overview 7/5 5TT5 remote control switches 7/8 5TT3 0 switching relays 7/9 5TT5 7 Insta contactors 7/10 5TT3 4 Soft-starting devices 7/11 5TT5 2 EMERGENCY-STOP modules /1

2 When things start hotting up: Electrical switching takes place every time a control system assumes control or automatic functions. Remote control switches for pulse control or Insta contactors switch the loads. The range of different demands ask for a broad spectrum of different contacts and rated currents. 6/2 7/2

3 Everything runs automatically. 7 BETA Electrical Switching 7/3

4 Product overview Overview Devices Application Standards Usage Non-res. buildings Res. buildings Industry Remote-control switches without central switching Switching of lighting by pushbutton DIN EN (VDE 0637) with central switching DIN EN (VDE 0632) with central and group switching Blind and series remote-control switch Electronic series remote-control switch Flush-mounting remote-control switches System remote-control switches without central switching with central switching with central and group switching Relays for PLCs Switching of small loads or application DIN EN (VDE 0435) in controllers for capacitive loads Specially suited for the switching of luminaires such as fluorescent lamps or high-pressure and metal-halide lamps, with capacitive properties Insta contactors Switching of motors, heating or lighting, such as fluorescent lamps or filament lamps, and resistive and inductive loads EN , EN , EN Soft-starting devices 5TT3 441, 230 V AC 5TT3 440, 400 V AC Protection of machines with transmission, belt or chain drives, conveyor (VDE 0660 Part 117) DIN EN , belts, fans, pumps, compressors, packing machines, door operating mechanisms Definitions I e = Rated operational current U e = Rated operational voltage I c = Rated control supply current U c = Rated control supply voltage P s = Rated operational capacity 1 MW = 18 mm modular width N-type EMERGENCY-STOP modules 5TT5 200, 10 A Electrical switching Uniform mounting depth Fitted with a transparent cap, these devices have the same uniform mounting depth valid for all products. EMERGENCY-STOP switching of machines in industrial, commercial and private economic applications acc. to the EC directive for machines 98/37/EG, DIN EN There are a number of general operational demands, particularly with regard to the switching of lighting, that need to be taken into consideration during planning. The technical background represented here is for illustration and clarification purposes and is intended to help you avoid planning errors and prevent the time and hassle caused by premature failures. 7/4 Siemens ET B1 2005

5 1 Overview 5TT5 remote-control switches 2 Remote-control switches 5TT5 5 5TT5 15 Blind and series remote control switches Electronic series remote control switches Flush-mounting remote control switches System remotecontrol switches 5TT5 16 5TT TT TT5 60 5TT5 61 5TT5 62 Manual operation Switch position indication Fuse protected against continuous voltage For different phases between magnet Yes, 5TT5 15 No no no no yes coil and terminals for central and group input Operating noises Standard quiet very quiet quiet very quiet Short-circuit strength up to 800 A Siemens ET B /5

6 5TT5 remote-control switches Selection and ordering data Version U e I e U c MW Order No. Price PG Weight PS*/ 1 item 1 item P. unit V AC A AC V AC V DC kg Items Remote-control switches with transparent cap Contact gap 3 mm, short-circuit strength up to 800 A 1 NO contacts TT / TT / TT / TT / TT / TT /12 5TT NO contacts TT / TT / TT / TT / TT / TT /12 1 CO contact TT / TT / TT / TT / TT /12 5TT5 150 with central switching, contact gap 3 mm, short-circuit strength up to 800 A 1 CO contact TT /12 2 NO contacts TT /12 3 NO contacts TT /6 with central and group switching, µ-contact, very quiet operation 1 NO contacts TT TT NO contacts TT TT Remote-control switches without transparent cap Contact gap 3 mm, short-circuit strength up to 800 A 3 NO contacts TT / TT / TT / TT /6 5TT5 503 Blind remote-control switch with transparent cap Contact sequence , contact gap 3 mm 2 NO contacts TT TT5 163 Series remote-control switches with transparent cap Contact sequence , contact gap 3 mm 2 NO contacts TT TT TT TT /6 Siemens ET B * You can order this quantity or a multiple thereof.

7 Selection and ordering data 5TT TT TT TT TG TG TG TT5 remote-control switches Version U e I e U c MW Order No. Price PG Weight PS*/ 1 item P. unit V AC A AC V AC V DC 1 item kg Items Electronic series remote-control switch with transparent cap Contact sequence , µ-contacts 2 NO contacts TT Remote-control system switches with transparent cap µ-contact, very quiet operation 1 NO contact TT TT TT with 2 switching systems 1 NO contact per switching system with central switching TT TT TT NO contact TT with central switching, with 2 switching systems 1 NO contact per switching system TT with central switching, with 3 switching systems 1 NO contact per switching system TT with central switching, with 3 switching systems 1 NO contact per switching system TT with central and group switching with transparent cap 1 NO contact TT with central and group switching, with 3 switching systems 1 NO contact per switching system Compensator, mounting depth 55 mm TT PTC resistor combination for increasing glow lamp loads Transparent caps TG Spare part for devices with an overall width of 1 MW 5TT5 5. Only for devices with an overall width of 1 MW. 1 set (1 set = 5 items) 1 5TG set Spare part for devices with an overall width of 1 MW 5TT3 0., 5TT3 1, 5TT3 4., 5TT5 1. and 5TT5 6. For devices with an overall width of 2 MW 5TT5 1. you need 2 transparent caps. 1 set (1 set = 5 items) 1 5TG set Spare part for devices with an overall width of 2 MW 5TT3 4., 5TT5 6. and 5TT set (1 set = 5 items) 2 5TG set * You can order this quantity or a multiple thereof. Siemens ET B /7

8 5TT3 0 switching relays Selection and ordering data 5TT TT3 061 Version U e I e U c MW Order No. Price PG Weight 1item PS*/ P. unit V AC A AC V AC V DC 1 item kg Items Switching relay with transparent cap 1) 1 NO contact TT TT TT TT TT NO contacts TT TT TT TT TT CO contact TT TT TT TT TT CO contacts TT TT TT for control with direct voltage 110 5TT TT CO contacts TT TT for switching capacitive loads; of lighting 30 5TT TT NO contact TT for control of PLCs Contact: 15 to 60 V, 2 to 30 ma according to EN , type 1 1 NO contact TT Sealable enable relay, mounting depth 55 mm Used for boiler/storage relays. In the case of continuous duty, a distance of 1 MW must be maintained between the devices. 1 CO contact TT TT ) For spare transparent caps see page 7/7. 7/8 Siemens ET B * You can order this quantity or a multiple thereof.

9 Selection and ordering data 5TT TT TT TT TT5 7 Insta contactors Version U e I e U c MW Order No. Price PG Weight 1item Insta contactor PS*/ P. unit V AC A AC V AC V DC 1 item kg Items for alternating current continuous operation, with switch position indication, with alternating current magnet system 2 NO contacts TT TT NO contact, 1 NC contact TT TT NC contacts TT TT for AC or DC continuous operation, with switch position indication, with DC magnet system 4 NO contacts TT TT TT NO contacts, TT NC contact TT NO contacts, TT NC contacts TT NC contacts TT TT NO contacts TT TT NO contacts, ) TT NC contact TT NO contacts, ) TT NC contacts TT NO contacts TT TT NO contacts, ) TT NC contact TT NO contacts, ) TT NC contacts TT Auxiliary switch for left-sided mounting on the 24-A, 40-A and 63-A Insta contactor; max. one auxiliary switch per Insta contactor. Minimum contact load 24 V AC; 5 ma 2 NO contacts 230, AC TT NO contact, 1 NC contact 230, AC TT Spacer for heat conduction between the Insta contactors. We recommend placing a spacer between each second Insta contactor. Can be mounted reciprocally, so that two spacers enable greater cable penetration 0.5 5TG TG TT ) For NC contacts 30 A. Sealable terminal covers 1 set for Insta contactor 24 A, (1 set = 2 items) 2 5TT set 1 set for Insta contactors 40 A and 63 A, (1 set = 2 items) 3 5TT set * You can order this quantity or a multiple thereof. Siemens ET B /9

10 5TT3 4 soft-starting devices Overview 1-phase 1.5 kw 3-phase 5.5 kw Increases the service life of one-phase asynchronous motors and mechanical drive equipment Can also be retrofitted in existing systems Separate setting of acceleration time and starting torque With LED display for startup or continuous operation The power semiconductors are bridged after completion of startup. Selection and ordering data Version U e P c MW Order No. Price PG Weight 1item PS*/ P. unit V AC W 1 item kg Items Soft-starting device with transparent cap 1) 1-phase TT L1 N AI2_ TT3 441 t acc M st T1 T2 t acc : Acceleration time M st : Starting torque Soft-starting device, mounting depth 55 mm 3-phase, 2-phase motor actuation TT L3 L2 L1 AI2_ TT3 440 t acc M st T3 T2 T1 t acc : Acceleration time M st : Starting torque 1) For spare transparent caps see page 7/7. 7/10 Siemens ET B * You can order this quantity or a multiple thereof.

11 Overview Scope The scope of the EC Directive Machines is no longer restricted to industrial machinery, but now covers virtually all machines for use in all areas of commercial and private trade and industry and applies to all Stationary Movable, Hand-held, Mobile Machine tools and processing machines Prime movers and production machines Risk analysis and selection of a suitable category Engineers and operators assume responsibility for the correct risk assessment. It is difficult to make a quantitative assessment of the risk, so that when selecting the category, the reasonable risk can be determined within a broad band width. Risk parameter S: seriousness of injury minor injury serious and irreversible injury of one or several persons or death of a person Benefits Acc. to the 98/37/EC EC directive for machines Safety category 4 acc. to DIN EN Acc. to the 98/37/EC EC directive for machines Selection and ordering data Risk parameter F: Risk parameter P: frequency and possibility of duration avoiding injuries rarely to frequently frequently to constantly possible under certain circumstances hardly possible possible under certain circumstances hardly possible 5TT5 2 EMERGENCY-STOP modules Compressors Operating and packaging machines Machines in underground mining Earthmoving machines and harvesters Hoisting equipment Floor conveyors Machines for lifting persons Plants Interchangeable equipment, such as snow ploughs and mountable sweeping devices This becomes clear if you select "F2 - frequently to continuous" instead of "F1 - rarely to frequently", for the risk parameters "F - Frequency and duration" when drawing up a risk graph (see image). The whole band width of safety categories may lie between the assessment of "often" and "frequently". Categories B Safety category 4 acc. to DIN EN Electrical isolation between electric circuit and control LED display for operation and circuit state I2_08404a preferred categories for reference points possible category which requires additional measures with regard to the risk overdimensioned measures with regard to the risk Version U e I e U c MW Order No. Price PG Weight 1item PS*/ P. unit V AC A V AC 1 item kg Items EMERGENCY-STOP module, mounting depth 55 mm TT TT5 200 * You can order this quantity or a multiple thereof. Siemens ET B /11

12 Notes 7/12 Siemens ET B1 2005

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

SENTRON SIVACON ALPHA

SENTRON SIVACON ALPHA SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 10/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution

More information

Miniature Circuit Breakers for Railway Applications

Miniature Circuit Breakers for Railway Applications Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent

More information

PLC. Module 3: Hardware and Terminology. IAT Curriculum Unit PREPARED BY. Jan 2010

PLC. Module 3: Hardware and Terminology. IAT Curriculum Unit PREPARED BY. Jan 2010 PLC Module 3: Hardware and Terminology PREPARED BY IAT Curriculum Unit Jan 2010 Institute of Applied Technology, 2010 ATE321 PLC Module 3: Hardware and Terminology Module Objectives Upon successful completion

More information

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in prom design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase Characteristics variable speed drive ATV310-3 kw - 4 hp - 380...460 V - 3 phase Complementary Product destination Main Range of product Altivar Easy 310 Product or component type Product specific application

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

ALPHA SIMBOX Small Distribution Boards

ALPHA SIMBOX Small Distribution Boards ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

QUICK START GUIDE. vau4/3. Frequency converter.   operating instructions /12 operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

PLC Fundamentals. Module 2: Hardware and Terminology. Academic Services Unit PREPARED BY. August 2011

PLC Fundamentals. Module 2: Hardware and Terminology. Academic Services Unit PREPARED BY. August 2011 PLC Fundamentals Module 2: Hardware and Terminology PREPARED BY Academic Services Unit August 2011 Applied Technology High Schools, 2011 ATE1212 PLC Fundamentals Module 2: Hardware and Terminology Module

More information

Safety Systems Safety Integrated

Safety Systems Safety Integrated 3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

VARIABLE SPEED DRIVES

VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES 0.4...30kW THREE-PHASE COMPACT, VERSATILE HIGH PERFORMANCE Automatic car washing equipment APPLICA TION AREAS Packaging Automatic and semi-automatic packaging

More information

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0

More information

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - on base plate Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011 Technical data 2CDC508136D0202 ABB i-bus KNX Product description The device is a modular installation device (MDRC) in Pro M design. It is intended for installation in distribution boards on 35 mm mounting

More information

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12H018M2 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 200..240V - 1ph Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

VARIABLE SPEED DRIVES

VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES 0.4...110kW THREE-PHASE COMPACT, VERSATILE HIGH PERFORMANCE Automatic car washing equipment APPLICA TION AREAS Packaging Automatic and semi-automatic packaging

More information

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW) Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product

More information

5SL Miniature Circuit Breakers

5SL Miniature Circuit Breakers 5SL Miniature Circuit Breakers BETA Low-Voltage Circuit Protection The new 5SL miniature circuit breaker is intended for use up to ka. The devices have the system features characteristic of all Siemens

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

Extension module for lighting control

Extension module for lighting control s 3 842 DESIGO RXC Extension module for lighting control Extension to the RXC30 / RXC31 / RXC38 room controller RXC40.1 RXC40.5 The RXC40 extension module is used in conjunction with an RXC30, RXC31 or

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW) Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

ABB ABB 143 2CDC110004C0205. Safety relays. C57x and C67xx range. Content

ABB ABB 143 2CDC110004C0205. Safety relays. C57x and C67xx range. Content ABB Safety relays C7x and C67xx range Content Selection table... 44 Approvals and marks... 44 Safety for man and machine... 46 General information... 46 Safety category acc. to EN 94-... 47 Standards,

More information

Welcome to the features training module for ACS industrial drive modules.

Welcome to the features training module for ACS industrial drive modules. Welcome to the features training module for ACS880-04 industrial drive modules. 1 ACS880-04 single drive modules are optimized for easy and cost-efficient cabinet assembly. This power intensive drive module

More information

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems SR 2ZH A 23 3 3 X S2 S A. K K2 PROTECT SR 2ZH Dimensions Two-hand module to DIN EN 574 (997) type III C Plug-in terminals 2 safety enabling outputs feedback output with NC function (floating contact) Electronic

More information

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual Fan Coil Actuators FCA/S Product Manual Contents 1 General... 5 1.1 Using the product manual...5 1.1.1 Notes...6 1.2 Product and functional overview...7 1.2.1 Product overview...7 1.2.2 Functional overview...8

More information

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink Product datasheet Characteristics ATV12H075M3 variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - with heat sink Complementary Main Range of product Altivar 12 Product or component type Product

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161 Technical Data 9AKK107045A4913 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual Fan Coil Actuators FCA/S Product Manual Contents 1 General... 5 1.1 Using the product manual...5 1.1.1 Notes...6 1.2 Product and functional overview...7 1.2.1 Product overview...7 1.2.2 Functional overview...8

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW) Product data sheet Characteristics ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW) Complementary Assembly style Function available Power supply voltage limits Main Range of

More information

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology   Page 1/10 General Description Room Control Unit RCU Series are designed as an all in one product for different room layouts such as apartments, hotel rooms, hospitals and residences. Available versions of EAE RCU

More information

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009 Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens

More information

PSR UC/ESAM4/3X1/1X2/B

PSR UC/ESAM4/3X1/1X2/B Safety relay for emergency stop and safety door monitoring Data sheet 105318_en_02 PHOENIX CONTACT 2014-06-13 1 Description The safety relay can be used in safety circuits according to EN 60240-1 and IEC

More information

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011 , 2CDG 110 15x R0011 SA/S 12.6.1.1 2CDC 071 033 S0012 The 6 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are suitable for

More information

VARIABLE SPEED DRIVES

VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES 0.4...75kW THREE-PHASE COMPACT, VERSATILE HIGH PERFORMANCE Automatic car washing equipment APPLICA TION AREAS Packaging Automatic and semi-automatic packaging

More information

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011 Technical Data 2CDC505054D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.6.2.1, 10 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0) SIMATIC ET 200S distributed I/O SIMATIC Preface ET 200S distributed I/O Digital electronic module 2DO AC24..230V (6ES7132-4FB01-0AB0) Properties 1 Parameters 2 Diagnostics 3 Manual 04/2007 A5E01077264-01

More information

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors

More information

Control Transformers Control transformers

Control Transformers Control transformers Control Transformers It is often desirable to operate the control circuit at a lower voltage than the power circuit. Control transformers are used to step a voltage down to a lower level. Siemens Class

More information

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22C17Q Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact Characteristics variable speed drive ATV320-0.37kW - 380...500V - 3 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

High-performance switching actuators

High-performance switching actuators High-performance switching actuators Wide-ranging applications efficient installation and set-up operation for many years The worldwide standard for home and building control siemens.com/gamma Switching

More information

Rev Operating Instructions Busch-Dimmer. Potentiometer U-101

Rev Operating Instructions Busch-Dimmer. Potentiometer U-101 1473-1-7906 Rev. 01 17.12.2012 Operating Instructions Busch-Dimmer Potentiometer 2112-101 2112 U-101 Busch-Dimmer 1 Safety... 3 2 Intended use... 3 3 Environment... 3 4 Technical data... 4 5 Setup and

More information

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n Safety module CS AT 0 Module for emergency stops, end position monitoring for movable guards with delayed contacts at the opening of the input channels, semiconductor outputs (e.g. light barriers and magnetic

More information

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00 Monitoring functions Evaluation of brush length monitoring, digital, non-floating Evaluation of brush length monitoring, digital, floating A00 A06 Non-floating brush length monitoring with use of KM01

More information

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1 Product datasheet Characteristics ATV630U15N4 variable speed drive ATV630-1.5kW/2HP - 380...480V - IP21/UL type 1 Main Range of product Product or component type Product specific application Device short

More information

SIGUARD Safety Systems Safety Integrated

SIGUARD Safety Systems Safety Integrated SE 10 / SE. 00 / SE. 4 / SE. 5 Molded plastic / metal enclosure with separate actuator Application Safety interlock switches (limit switches) with separate actuator are used where the position of doors,

More information

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories / SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in

More information

Large Frame IEC Contactors

Large Frame IEC Contactors Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge arresters, type

More information

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW) Characteristics soft starter-ats22-control 220V-power 230V(15kW)/400...440V(30kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

SIMOREG 6RA70 DC MASTER SIMOREG CM

SIMOREG 6RA70 DC MASTER SIMOREG CM SIMOREG RA70 DC MASTER /2 Application /2 Design /3 Technical Data /3 Standards /4 Block diagram / Options Siemens DA 21.1 200 /1 SIMOREG RA70 DC MASTER Application An important application for the converter

More information

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

Safety relays C57x and C67xx range

Safety relays C57x and C67xx range C7x and C67xx range Content Selection tables... 112 Safety for man and machine, General information... 114 Safety for man and machine, Safety category acc. to EN 94-1... 11 Safety for man and machine,

More information

Labeling accessories Art.-No. suitable. Wiring accessories Art.-No. suitable. Color: blue 10-pole spacing 6.2 mm MIRO 6.2

Labeling accessories Art.-No. suitable. Wiring accessories Art.-No. suitable. Color: blue 10-pole spacing 6.2 mm MIRO 6.2 Labeling accessories suitable ACS label plate KM 5 7000-99001-0000000 Relays, solid state relays, opto-coupler, intelligent interface technology, passive interface technology, eurocard holder, modules

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B

More information

Product Family: Electro Mechanical Relays Number: AN-LC-008

Product Family: Electro Mechanical Relays Number: AN-LC-008 APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type

More information

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W Characteristics Preventa safety module - 24 V DC - standard format - < 5 W Main Range of product Product or component type Complementary [Us] rated supply voltage Supply voltage limits Activation threshold

More information

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data

More information

Solid-State Switching Devices

Solid-State Switching Devices Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data

More information

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS Safety Controller Suitable for use with Coded-Magnet Sensor Part Numbers below BNS250... BNS33... BNS303...

More information

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical

More information

Crane Control Contactors and Relays

Crane Control Contactors and Relays October 8 DC Relays Type KC Heavy-Duty Mill 75 Contact Conversion The fully visible contacts have NEMA ICS--5 heavy-duty interrupting ratings and are easily converted in the field using just a screwdriver

More information

Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor

Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor Features M Safety-category 4 acc. to DIN EN954-1 M Stop-category 0 M Crossfault monitoring M Monitored start (On-switch) or automatic start

More information

Latching, Sequence and Impulse Relays Application Data

Latching, Sequence and Impulse Relays Application Data Latching, Sequence and Impulse Relays Application Data Energy Conservation Relays In many applications it is important for the customer to conserve electrical energy. One approach to energy conservation

More information

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate Characteristics variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - on base plate Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Complementary Assembly style Function available Power supply voltage limits Main Commercial Status Commercialised

More information

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart

More information

Switching module for AC V and up to three load stages, with manual switching

Switching module for AC V and up to three load stages, with manual switching 8 149 PTM13-M3 DESIGO I/O modules Switching module for AC 24 250 V and up to three load stages, with manual switching PTM13-M3 Signal converter for connection to P-bus, with three interlocked on/off control

More information

3RP, 7PV Timing Relays

3RP, 7PV Timing Relays 3RP, PV Timing Relays Overview Standards The timing relays comply with: EN 6021-3-3 "Environmental conditions" EN 61812-1/DIN VDE 0435 Part 2021 "Solid-state relays, timing relays" EN 61000-6-2 and EN

More information

Lightning and Surge Arresters

Lightning and Surge Arresters Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement

More information

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink Characteristics variable speed drive ATV12-2.2kW - 3hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

New Solutions. for AC Motor Starters

New Solutions. for AC Motor Starters ADAPTABILITY RELIABILITY CREATIVITY New Solutions for AC Motor Starters Featuring : Electronic Centrifugal Switches for Capacitor Start (Capacitor Run) Motors / Digital Motor Starters for Three Phase Bidirectional

More information

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book Characteristics variable speed drive ATV320-15kW - 380...500V - 3 phase - book Main Range of product Product or component type Product specific application Device short name Format of the control block

More information

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book Characteristics variable speed drive ATV320-15kW - 380...500V - 3 phase - book Main range of product product or component type product specific application device short name format of the drive product

More information

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book Characteristics variable speed drive ATV320-11kW - 380...500V - 3 phase - book Main range of product product or component type product specific application device short name format of the drive product

More information

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW Characteristics soft starter for asynchronous motor - ATSU01-9 A - 200..480V - 1.5..4 KW Complementary Assembly style Function available Power supply voltage limits Main Range of product Product or component

More information

Motor protection circuit breakers

Motor protection circuit breakers R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,

More information

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives Building Technologies SED2 Variable Frequency Drives More standard features Means better control of HVAC applications The global leader in Heating, Ventilation and Air Conditioning (HVAC) products and

More information

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2. 66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety Drive Technology \ Drive Automation \ System Integration \ Services Manual Control Cabinet Inverter MOVITRAC B Functional Safety Edition 05/2009 16811216 / EN SEW-EURODRIVE Driving the world Content Content

More information

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

SAFETY RELAY YRB-4EML-31S MAIN FEATURES SAFETY RELAY TYPE 4 SAFETY PROTECTION DEVICE FOR SAFETY LIGHT CURTAINS/BARRIERS MAIN FEATURES For safety light curtains and access control barriers, emergency stop, door switch Safety Integrity Level (SIL)

More information

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor

More information

Active Front End Drives: Lower Harmonics, Higher Energy Savings

Active Front End Drives: Lower Harmonics, Higher Energy Savings Active Front End Drives: Lower Harmonics, Higher Energy Savings 2 Active Front End Drives: Harmonics Performance Overview 1.0 Evolution of VFDs When variable-frequency drives (VFDs) arrived on the industrial

More information