Surge protection for information technology

Size: px
Start display at page:

Download "Surge protection for information technology"

Transcription

1 PHOENIX CONTACT

2 Surge protection for information technology Main range Features Selection guide 8 Low signal levels with high frequencies require special protective circuits in data processing and telecommunications. The arresters must guarantee short response times to quickly limit surge voltages to safe values, without impairing signal quality. In addition, TRABTECH protective devices support system-specific connections, such as RJ or D-SUB connectors, and all types of network topologies. Data systems Ethernet, token ring 0 V./RS- V./RS- TTY RS-8 TERBUS 8 PROFIBUS 0 Telecommunications ISDN S 0 interfaces ISDN U k0 interfaces Analog interfaces Applications 0 PHOENIX CONTACT

3 Main range DATATRAB DT Transmission speeds of up to 0 Gbps DT-UFB-8/BS DT-TELE-RJ RJ connection for various interfaces Snap-on foot for D rail Protection for various interfaces Ethernet (including PoE) Token ring ISDN DSL Analog telephone RS-8 : Ground connection when used as an adapter PHOENIX CONTACT

4 DATATRAB DT - The all-round solution for protecting data interfaces Surge protection for information technology and telecommunications Main range DATATRAB DT reliably protects highspeed networks against damage caused by surge voltages. DT-LAN-CAT.+ supports various data protocols at very high transmission speeds, such as Ethernet, Power over Ethernet (PoE), ISDN, token ring, and DS, in a single device. Other versions are available in this product range for the RS-8 bus interface as well as for analog and digital telecommunications interfaces including DSL. The different versions comply with the relevant system and have the appropriate connection method. The housing has a ground connection snap-on foot into which the ground connection cover with equipotential bonding line is inserted. This means that DATATRAB can be used as an adapter or a D rail module after removing the ground connection cover. Use One protective device suitable for various applications (Ethernet, token ring, CDDI, ISDN, DS, analog telecommunications, ISDN, DSL, RS-8, V., V., etc.). Both versions of Power over Ethernet (PoE) (midspan and endspan) are also supported. Speed Used in EDP systems with transmission speeds of up to 0 Gbps (CAT./ CLASS Ea) and in telecommunication networks with Mbps (ADSL+). Versatility Flexible installation using RJ female connectors instead of fixed cables. The cable length required at the installation location can be determined by selecting standard patch cables. Easy installation Integration of a variable connection and installation option for discharging surge voltages. This device can be connected to a solution for discharging surge voltages (e.g., a cable) and also snapped onto a D rail with surge-current-resistant contact. PHOENIX CONTACT

5 Features DATATRAB D-LAN... Protective device in 9" housing Connection for equipotential bonding line EMC housing System-compliant connection for Ethernet, token ring, FDDI/CDDI... Multifunctional protective circuit all 8 signal wires are protected COMBITRAB/MATRAB Operating indicator Recessed ON/OFF switch.8 m connecting cable Optional integrated signal interface protection, such as TV-SAT, ISDN, etc. Country-specific versions Operating indicator Increased touch-proof protection PHOENIX CONTACT

6 Features PLUGTRAB PT... Plug-in surge protection Uninterruptible and impedance-neutral insertion and removal Labeling option Barcode for CHECKMASTER Mechanical protection against polarity reversal PLUGTRAB base element PT-BE Signal ground to ground potential Keying for circuit type and voltage level Surge-current-resistant contact with D rail PLUGTRAB base element PT+F-BE Signal ground via spark gap to ground potential Labeling possible on input and output side.8 mm of space required per signal. mm design width COMTRAB modular CTM... CTM magazine with grounded rail for accommodating up to 0 CTM connectors Protective connector can be tested with CHECKMASTER Protection that can be individually assembled in one magazine TERMIBLOCK terminal base for D rails Suitable for TERMIBLOCK and LSA-PLUS disconnect and control strips Contacting of the reference potential PHOENIX CONTACT

7 Selection guide The interface matrix indicates which surge protective device is suitable for a specific interface. Technology Interface AS-Interface CAN bus ControlNet Data Highway (Plus), DH+ DeviceNet Fast Ethernet (00BaseT) Gigabit Ethernet Foundation Fieldbus Ex(i) TERBUS Inline remote bus Data systems TERBUS Inline I/O TERBUS field multiplexer PROFIBUS DP (FMS) PROFIBUS PA PROFET RS-A, V., X., RS-A RS-8 RS--C/V. SEC L DP (~ PROFIBUS DP) Token ring TTY, 0() - 0 ma ADSL, T-DSL, HDSL Note Products bearing this stamp (connector elements) can be tested with the CHECKMASTER. Telecommunications ATM ISDN (S 0 & S M bus) ISDN (U k0 & U k interface) Analog telephone 8 PHOENIX CONTACT

8 Selection guide Adapter D rail module Outlet box LSA-PLUS technology Socket strip Arrester Page PT +-S-8DC-ST & PT -BE/FM (yellow cable) PT -PE/S-AC & PT-BE/FM (black cable) PT -HF-DC-ST & PT x-be (bus) PT -PE/S-AC & PT-BE/FM (power supply) C-UFB-DC/E PT--HF-DC-ST & PT x+f-be PT -HF-DC-ST & PT x-be (bus) PT -PE/S-AC & PT-BE/FM (power supply) DT-LAN-CAT.+ or D-LAN-9" CBT-M-RJ/ 0 DT-LAN-CAT.+ PT XEX(I)-DC-ST & PT xex(i)-be (bus) 99 PT -PE/S-AC-ST & PT-BE/FM (power supply) PT -HF-DC-ST & PT x+f-be 00 DT-UFB-IB-RBI 8 DT-UFB-IB-RBO 9 PT x-ac-st & PT x-be 9 PT x-ac-st & PT x-be 9 CTM x-dc & CTM 0-MAG PT -PB-ST & PT x+f-be 0 PT -PB-ST & PT x-be 0 PT -HF-DC-ST & PT x-be 00 D-UFB-PB PT xex(i)-dc-st & PT xex(i)-be 99 PT -EX(I)-DC-ST & PT -EX(I)-BE 99 DT-LAN-CAT.+ PT -HF-DC-ST & PT x+f-be PT -HF-DC-ST & PT x+f-be DT-UFB-8/BS PT -HF-DC-ST & PT x+f-be DT-UFB-V/... PT -PB-ST & PT x-be 0 PT -HF-DC-ST & PT x-be 00 D-UFB-PB DT-LAN-CAT.+ or D-LAN-9" PT--HF-DC-ST & PT x-be 00 PT x-dc-st & PT x-be CTM x-dc & CT 0-MAG PT -TELE CTM x-0ac & CTM 0-MAG 9 MNT-TAE D MNT-TELE DT-LAN-CAT.+ D-LAN-9" CTM ISDN 8 WT-RJ-...ISDN CBT-ISDN DT-LAN-CAT.+ PT -TELE MNT-TAE D MNT-TELE CTM x-0ac & CTM 0-MAG 9 TAE-TRAB FM... / WT-RJ -S/FM A/K AP DT-TELE-RJ 9 PT -TELE PHOENIX CONTACT 9

9 Ethernet, FDDI/CDDI, Token Ring Surge protection for Ethernet/PROFET networks with twisted pair cabling CBT-M-RJ/ Easy operation Combination of ground contact sockets and RJ female connector For Ethernet and token ring networks Corresponds to category (up to 00 Mbps) Notes: Dimensional drawings starting on page 0 Approvals starting on page Attenuation curves, from page DT-LAN-CAT.+ Suitable for category high-speed data networks Reliable transmission speeds up to 0 Gbps Protective adapter for eight signal paths via RJ connector Can be installed in a control cabinet by removing a ground connection adapter D-LAN-9" 9" rack for installation in storey distributors Up to ports with RJ connection Protection of all eight signal wires of the data cable Indirect grounding via a gas-filled surge arrester in the housing Direct grounding via a connection on the housing DATA-PLUGTRAB PT -HF Protection for up to five signal wires For high transmission speeds High discharge capacity Connectors can be checked with CHECKMASTER * Note: Various grounding options for the base elements: PT.x.-BE connections 9/0 (GND) directly connected to the mounting foot. PT.x.+F-BE connections 9/0 (GND) connected to the mounting foot via a gasfilled surge arrester. Total width mm Electrical data Mains protection Data protection IEC category / EN type III / T C / C Maximum continuous operating voltage U C 0 V AC. V DC Nominal current I N A (0 C). A ( C) Nominal discharge surge current I n (8/0) μs Core-Core / Core-Ground. ka /. ka 0 A /. ka Combined surge U OC kv - Protection level U P Core-Core / Core-Ground. kv /. V V /. kv Total surge current (8/0) s -. ka Output voltage limitation at kv/μs Core-Core / Core-Ground - / - V /. kv Cut-off frequency fg ( db) In a 00 system Core-Core / Core-Ground - > 00 MHz / - General data Temperature range -0 C C Degree of protection according to IEC 09/EN 09 IP0 Inflammability class according to UL 9 V0 Connection method RJ Test standards IEC - / EN - IEC - Can be used as typical for Description the country COMBITRAB, combination of two ground contact sockets and RJ connection for LAN interfaces For network and LAN interface, with. m connecting cable and RJ connection N N 0V! L L D, A, I, NL, E, P CBT-M-RJ/ 90 DATATRAB adapter, protective adapter for inserting in the data line DATATRAB, for use in Ethernet, token ring, FDDI/CDDI, according to Class D/CATe of EN 0 (00BaseT) ports 0 ports ports ports 8 ports ports Surge protection PCB, as a replacement or for retrofitting in D-LAN-9"... products, incl. RJ female connector ports Patch cable, CAT, pre-assembled m long FL CAT PATCH, PLUGTRAB connector, with protective circuit for inserting in PT base element Male connector Base element 0 PHOENIX CONTACT

10 Ethernet, FDDI/CDDI, Token Ring For LAN interfaces (Class Ea/CAT) including PoE and ISDN S0 protection For data interfaces, with RJ connection Class D/CATe Plug-in arrester with screw connection, for five conductors, with common reference potential Total width mm Total width 8 mm Total width. mm 8 8 J J * 0 B / C / C C / C / C C / C / C. V DC (±0 V DC / PoE) V DC. V DC. A ( C). A ( C) 0 ma ( C) 00 A / ka (per signal pair) 0 A / 0 A 0 ka / 0 ka V (B ( kv/ A) ) / 00 V (C ( kv/ ka)) 0 V (C, 00 V/0 A) / 0 V (C, 00 V/0 A (J ON)) - / - 0 ka 0 ka 0 ka 9 V / 00 V 0 V / 0 V (J plugged) V / V > 00 MHz / - > 00 MHz / - Typ. 0 MHz / - -0 C... 0 C -0 C C -0 C... 8 C IP0 IP0 IP0 - - V0 RJ RJ Screw connection (in connection with the base element) IEC - / EN 0- / ISO/IEC 80-Am. IEC - / D EN 0- IEC - DT-LAN-CAT D-LAN-9"- 889 D-LAN-9" D-LAN-9"- 880 D-LAN-9" D-LAN-9" D-LAN-9"- 880 D-LAN-9"-D-P 8809 FL CAT PATCH, PT -HF- DC-ST 88 0 PT X-BE For additional information, visit PHOENIX CONTACT

11 V./RS- Protection for V. (RS-) interfaces DT-UFB-V/S Connection: 9-pos. D-SUB and -pos. D-SUB For data and handshake cables Notes: Dimensional drawings starting on page 0 Approvals starting on page Attenuation curves, from page PLUGTRAB PT -HF-DC Connection: Screw terminal blocks For high transmission speeds High discharge capacity Connectors can be checked with CHECKMASTER Pin assignment DT-UFB-V/S-9-SB,,,,,,8,9 Data lines Signal ground (ground) Pin assignment DT-UFB-V/S-SB-SET,,,,,8,0, data lines Signal ground (ground) Pin assignment PT -HF-DC. Data lines 9 Signal ground (ground) Ground * Note: Various grounding options for the base elements: PT.x.-BE connections 9/0 (GND) directly connected to the mounting foot. PT.x.+F-BE connections 9/0 (GND) connected to the mounting foot via a gasfilled surge arrester. Total width mm Electrical data IEC category / EN type B / C / C / C Maximum continuous operating voltage U C V DC / 0 V AC Nominal current I N A ( C) Nominal discharge surge current I n (8/0) μs Core-Ground / Core-GND 0 A / 0 A Total surge current (8/0) s ka Output voltage limitation at kv/μs Core-Core / Core-GND 0 V / 0 V Cut-off frequency fg ( db) In a 00 system Symmetrical / Asymmetrical Typ.. MHz / Typ.. MHz General data Temperature range -0 C... 8 C Degree of protection according to IEC 09/EN 09 IP0 Inflammability class according to UL 9 - Connection method D-SUB-9 Protective adapter with 9-pos. D-SUB Connection data solid / stranded / AWG - Test standards IEC - Description DATATRAB adapter, protective adapter for inserting in the data line to protect the V./RS- interface with 9-pos. D-SUB connector DATATRAB adapter, protective adapter for inserting in the data line to protect the V./RS- interface with -pos. D-SUB connector PLUGTRAB connector, with protective circuit for inserting in PT base element Protection for V. (RS-) interfaces PLUGTRAB base element, for mounting on NS With gas-filled surge arrester between connections / ( ) and 9/0 DT-UFB-V/S-9-SB 8009 Accessories Assembled D-SUB cable, shielded, stranded (-wire), male connector to female connector D-SUB 09 VS-09-DSUB-0-LI-,0 Labeling material PHOENIX CONTACT

12 V./RS- Protective adapter with 9-pos. D-SUB and adapter cable with -pos. D-SUB Plug-in arrester with screw connection, for three conductors, with common reference potential Total width mm Total width. mm * 8 0 B / C / C / C C / C / C / D V DC / 0 V AC V DC / 9.8 V AC A ( C) 0 ma ( C) 0 A / 0 A 0 ka / 0 ka ka 0 ka 0 V / 0 V V / - Typ.. MHz / Typ.. MHz Typ. 0 MHz / - -0 C... 8 C -0 C... 8 C IP0 IP0 - V0 D-SUB- Screw connection (in connection with the base element) - 0. mm² - mm² / 0. mm² -. mm² / - IEC - IEC - DT-UFB-V/S-SB-SET 800 PT -HF-DC-ST PT X+F-BE 8 0 Accessories Accessories ZBF..., see page For additional information, visit PHOENIX CONTACT

13 V./RS- Surge protection for V./RS- interfaces For floating signal circuits or signal cables For high data transmission rates Connectors can be checked with CHECKMASTER Pin assignment PT -HF-DC:, Data line pair : T(A), T(B), Data line pair : R(A), R(B) 9 Signal ground (ground) Grounding * Note:PT.x.+F-BE connections 9/0 (GND) are linked to the mounting foot via a gas-filled surge arrester. Notes: Dimensional drawings starting on page 0 Approvals starting on page Attenuation curves, from page Plug-in arrester with screw connection, for five conductors, with common reference potential Total width. mm 8 9 * 0 Electrical data IEC category / EN type C / C / C / D Maximum continuous operating voltage U C V DC / 9.8 V AC Nominal current I N 0 ma ( C) Nominal discharge surge current I n (8/0) μs Core-Core / Core-Ground 0 ka / 0 ka Total surge current (8/0) s 0 ka Output voltage limitation at kv/μs Core-Core / Core-Ground V / V Cut-off frequency fg ( db) In a 00 system Symmetrical Typ. 0 MHz General data Temperature range -0 C... 8 C Degree of protection according to IEC 09/EN 09 IP0 Inflammability class according to UL 9 V0 Connection method Screw connection (in connection with the base element) Connection data solid / stranded / AWG 0. mm² - mm² / 0. mm² -. mm² / - Test standards IEC - Description PLUGTRAB connector, with protective circuit for inserting in PT base element V DC PT -HF- DC-ST 88 0 PLUGTRAB base element, for mounting on NS Gas-filled surge arrester between / ( ) and 9/0 PT X+F-BE 89 0 Labeling material ZBF..., see page Accessories PHOENIX CONTACT

14 Surge protection for TTY interfaces For floating signal circuits or signal cables Low voltage limitation Fast response High discharge capacity Connectors can be checked with CHECKMASTER Pin assignment PT x-dc...: / Data line pair A / Data line pair B * Note: Various grounding options for the base elements: PT.x.-BE connections 9/0 (GND) directly connected to the mounting foot. PT.x.+F-BE connections 9/0 (GND) connected to the mounting foot via a gasfilled surge arrester. Surge protection for information technology and telecommunications Notes: Dimensional drawings starting on page 0 Approvals starting on page Attenuation curves, from page Total width. mm Two double wires (loops), floating, for 0 ma current loops 9 * 0 TTY 8 Electrical data IEC category / EN type C / C / C / D Maximum continuous operating voltage U C 8 V DC / 0 V AC Nominal current I N 0 ma ( C) Nominal discharge surge current I n (8/0) μs Core-Core / Core-Ground 0 ka / 0 ka Total surge current (8/0) s 0 ka Output voltage limitation at kv/μs Core-Core / Core-Ground 0 V / 0 V Cut-off frequency fg ( db) In a 0 system Symmetrical Typ. MHz General data Temperature range -0 C... 8 C Degree of protection according to IEC 09/EN 09 IP0 Inflammability class according to UL 9 V0 Connection method Screw connection (in connection with the base element) Connection data solid / stranded / AWG 0. mm² - mm² / 0. mm² -. mm² / - Test standards IEC - / D EN - / UL 9B Description PLUGTRAB connector, with protective circuit for inserting in PT base element PT X-DC-ST PLUGTRAB base element, for mounting on NS Bridge between / ( ) and 9/0 PT X-BE Gas-filled surge arrester between / ( ) and 9/0 PT X+F-BE 89 0 Accessories Shield fast connection For Ø - mm SSA For Ø - 0 mm SSA Labeling material ZBF..., see page For additional information, visit PHOENIX CONTACT

15 RS-8 Surge protection for RS-8 interfaces PLUGTRAB PT -HF For floating signal circuits or signal cables Fast response time High transmission speed High discharge capacity Connectors can be checked with CHECKMASTER Pin assignment PT -HF...:, Data line pair T(A)/T(B), Data line pair R(A)/R(B) 9 Signal ground (ground) Notes: Dimensional drawings starting on page 0 Approvals starting on page Attenuation curves, from page Plug-in arrester with screw connection, for five conductors, with common reference potential DATATRAB DT-UFB-8 Adapter type 9-pos. D-SUB connection D rail mounting possible by removing the cap Pin assignment DT-UFB-8:,8 Data line pair T(A)/T(B),9 Data line pair R(A)/R(B), Signal ground (ground) BOXTRAB BXT-M/... In splash-proof surface-mounted housing Combined protection of the data interface and power supply Data interface already integrated in basic versions PRT-S- /FM plug-in power supply device protection can be retrofitted as an option For the technical data of PRT-S..., see page * Note: Various grounding options for the base elements: PT.x.-BE connections 9/0 (GND) directly connected to the mounting foot. PT.x.+F-BE connections 9/0 (GND) connected to the mounting foot via a gasfilled surge arrester. Total width. mm Electrical data... DC... DC IEC category / EN type C / C / C / D C / C / C / D Maximum continuous operating voltage U C. V DC /. V AC V DC / 9.8 V AC Nominal current I N 0 ma ( C) 0 ma ( C) Nominal discharge surge current I n (8/0) μs Core-Core / Core-Ground 0 ka / 0 ka 0 ka / 0 ka Total surge current (8/0) s 0 ka 0 ka Output voltage limitation at kv/μs Core-Core / Core-Ground V / V V / V Cut-off frequency fg ( db) In a 00 system Symmetrical / Asymmetrical Typ. 0 MHz / - Typ. 0 MHz / - General data Temperature range -0 C... 8 C Degree of protection according to IEC 09/EN 09 IP0 Inflammability class according to UL 9 V0 Connection method Screw connection (in connection with the base element) Connection data solid / stranded / AWG 0. mm² - mm² / 0. mm² -. mm² / - Test standards IEC - Description PLUGTRAB connector, with protective circuit for inserting in PT base element V DC PT -HF- DC-ST 88 0 V DC PT -HF- DC-ST 88 0 PLUGTRAB base element, for mounting on NS Bridge between / ( ) and 9/0 PT X-BE Gas-filled surge arrester between / ( ) and 9/0 PT X+F-BE 89 0 DATATRAB adapter, protective adapter for inserting in the data line to protect the RS-8 interfaces 9 * 8 0 BOXTRAB, protection for RS-8 and optional protection of the power supply unit with the PRT-S... protective connector Without PRT-S device protection connector With PRT-S device protection connector MAS-PRTRAB, device protection connector with temperature monitoring and visual fault warning, plus remote indication contact Accessories Labeling material ZBF..., see page PHOENIX CONTACT

16 RS-8 Protective adapter with 9-pos. D-SUB IP data protection ( V) IP data protection ( V) Total width mm Total width 00 mm Total width 00 mm 8, 8, T(A) T(B) R(A) R(B) T(A) L T(B) R(A) PE R(B) N T(A) T(B) R(A) R(B) T(A) L T(B) R(A) PE R(B) N GND GND FM GND GND FM 9 9 BXT-M/PLI- BXT-M/PLI- B / C / C / C / D B / C / C / C / D B / C / C / C / D B / C / C / C / D V DC / -. V DC / - V DC / - V DC / - 80 ma ( C). A ( C). A ( C). A ( C) ka / ka 0 A / ka 8 A / ka 8 A / ka 0 ka ka ka ka V / 00 V V / 0 V 0 V / 0 V 0 V / 0 V Typ. 0 MHz / - Typ. 00 MHz / - Typ. 00 MHz / - Typ. 00 MHz / - -0 C... 8 C -0 C... C -0 C... C IP0 IP IP D-SUB-9 Screw terminal blocks Screw terminal blocks 0. mm² -. mm² / 0. mm² - mm² / - 0. mm² -. mm² / 0. mm² - mm² / - D EN - D EN - / D EN -/A / IEC - / D EN - D EN - / D EN -/A / IEC - / D EN - DT-UFB-8/BS 90 BXT-M/RS8-TTL 998 BXT-M/PLI- 80 BXT-M/PLI- 889 Accessories Accessories Accessories PRT-S-0/FM PRT-S-0/FM PRT-S-0/FM 98 0 PRT-S-0/FM 98 0 For additional information, visit PHOENIX CONTACT

17 TERBUS Surge protection for the TERBUS remote bus DATATRABDT-UFB-IB-RBI/ -RBO Adapter type 9-pos. D-SUB connection For remote bus modules D rail mounting possible by removing the cap D-SUB cable included Notes: Dimensional drawings starting on page 0 Approvals starting on page Attenuation curves, from page PLUGTRAB PT -HF Fast response time High transmission speed High discharge capacity Connectors can be checked with CHECKMASTER Protective adapters for -wire remote bus input Total width mm * Note:PT.x.+F-BE connections 9/0 (GND) are linked to the mounting foot via a gas-filled surge arrester. I I I I Electrical data IEC category / EN type B / C / C / C / D Maximum continuous operating voltage U C.8 V DC / - Nominal current I N 80 ma ( C) Nominal discharge surge current I n (8/0) μs Core-Core / Core-Ground ka / ka Total surge current (8/0) s 0 ka Output voltage limitation at kv/μs Core-Core / Core-Ground V / 00 V Cut-off frequency fg ( db) In a 00 system Symmetrical 00 MHz In a 0 system Symmetrical 00 MHz General data Temperature range -0 C... 8 C Degree of protection according to IEC 09/EN 09 IP0 Inflammability class according to UL 9 - Connection method D-SUB-9 Connection data solid / stranded / AWG - Test standards D EN - / IEC - Description DATATRAB adapter, protective adapter for inserting in the data line PLUGTRAB connector, with protective circuit for inserting in PT base element V DC PLUGTRAB base element, for mounting on NS Gas-filled surge arrester between / ( ) and 9/0 TERMITRAB, modular terminal block with integrated surge protection, for mounting on NS DT-UFB-IB-RBI 8000 Labeling material Accessories 8 PHOENIX CONTACT

18 TERBUS Protective adapters for -wire remote bus output Plug-in arrester with screw connection, for five conductors, with common reference potential Total width mm Total width. mm I I I 8 I 9 * 0 B / C / C / C / D C / C / C / D.8 V DC / -. V DC /. V AC 80 ma ( C) 0 ma ( C) ka / ka 0 ka / 0 ka 0 ka 0 ka V / 00 V V / V 00 MHz Typ. 0 MHz 00 MHz - -0 C... 8 C -0 C... 8 C IP0 IP0 - V0 D-SUB-9 Screw connection (in connection with the base element) - 0. mm² - mm² / 0. mm² -. mm² / - D EN - / IEC - IEC - DT-UFB-IB-RB PT -HF- DC-ST 88 0 PT X+F-BE 89 0 Accessories TT-SLKK-F/0AC 0 0 ZBF..., see page Accessories For additional information, visit PHOENIX CONTACT 9

19 PROFIBUS Surge protection for PROFIBUS PT -PB Protection for two signal wires with common reference potential Data transmission rate up to Mbps For TERBUS/PROFIBUS systems For field multiplexers Connectors can be checked with CHECKMASTER Pin assignment PT -PB:, Data line pair 9 Signal ground (ground) Notes: Dimensional drawings starting on page 0 Approvals starting on page Attenuation curves, from page Plug-in arrester with screw connection, for five conductors, with common reference potential D-UFB-PB Direct use at the interface Data transmission rate up to Mbps Integrated termination resistor Total width. mm 8 * Note:PT.x.-BE connections 9/0 (GND) are linked directly to the mounting foot. 9 * 0 Electrical data IEC category / EN type C / C / C / D Maximum continuous operating voltage U C. V DC /. V AC Nominal current I N 0 ma ( C) Nominal discharge surge current I n (8/0) μs Core-Core / Core-Ground 0 ka / 0 ka Total surge current (8/0) s 0 ka Output voltage limitation at kv/μs Core-Core / Core-Ground V / V Cut-off frequency fg ( db) In a 00 system Symmetrical Typ. 0 MHz General data Temperature range -0 C... 8 C Degree of protection according to IEC 09/EN 09 IP0 Inflammability class according to UL 9 V0 Connection method Screw connection (in connection with the base element) Connection data solid / stranded / AWG 0. mm² - mm² / 0. mm² -. mm² / - Test standards IEC - Description PLUGTRAB connector, with protective circuit for inserting in PT base element PT -PB-ST PLUGTRAB base element, for mounting on NS Bridge between / ( ) and 9/0 PT X-BE 8 0 DATATRAB, protective device for PROFIBUS DP applications with up to Mbps Accessories Shield fast connection For Ø - mm SSA For Ø - 0 mm SSA Labeling material ZBF..., see page 0 PHOENIX CONTACT

20 PROFIBUS Fine protection with 9-pos. D-SUB Total width. mm B VP A GND B D(P) A 8 D(N) C / C / B. V DC / - 0 ma ( C) 0 A / 0 A 0 A V / V Typ. 0 MHz -0 C... C IP0 - Screw connection and D-SUB-9 0. mm² -. mm² / 0. mm² -. mm² / - IEC - D-UFB-PB 880 Accessories For additional information, visit PHOENIX CONTACT

21 ISDN S0 interface For power supply and telecommunications interface CBT-ISDN / MNT-ISDN Compact protection for termination devices Easy operation Combined power supply and ISDN protection Connection to telecommunications socket using separate cable Thermal monitoring of the protective circuit Green LED - operating indicator for the power supply On/off button in the socket strip DT-LAN-CAT.+ Protective adapter for eight signal paths via RJ connector Can be installed in a control cabinet by removing a ground connection adapter Notes: Dimensional drawings starting on page 0 Approvals starting on page Attenuation curves, from page For network and ISDN protection, with. m connecting cable and RJ connection Total width 8 mm b a b a PE N L WT-RJ -S/ISDN /K AP Surface-mounted socket With RJ female connector as IAE Optimum in-house protection for sensitive interfaces Electrical data Mains protection Data protection IEC category / EN type III / T C / C / D Nominal voltage U N 0 V AC - Maximum continuous operating voltage U C 0 V AC V DC Nominal current I N A (0 C). A ( C) Nominal discharge surge current I n (8/0) μs Core-Core / Core-Ground. ka /. ka 0 A /. ka Combined surge U OC kv - Protection level U P Core-Core / Core-Ground. kv /. kv V / 0 V Total surge current (8/0) s - - Output voltage limitation at kv/μs Core-Core / Core-Ground - / - 0 V / 0 V Cut-off frequency fg ( db) In a 00 system Core-Core - Typ. 80 khz General data Temperature range -0 C... C Degree of protection according to IEC 09/EN 09 IP0 Inflammability class according to UL 9 V0 Connection method RJ Test standards IEC - / EN -/A IEC - Description Can be used as typical for the country COMBITRAB, combination of five ground contact sockets and ISDN protection Black D, I, NL, E, P CBT-ISDN 8 MATRAB, surge protection attachment plug for inserting in a socket for equipment and data interface protection, incl.. m coaxial cable Black D, A, NL White D, A, NL Black B, F, CZ, SVK, PL White S, F, N DATATRAB adapter, protective adapter for inserting in the data line Patch cable, CAT, pre-assembled WESTERNTRAB, RJ outlet box, surface-type with surge protection for ISDN S o bus interface PHOENIX CONTACT

22 ISDN S0 interface For network and ISDN/RDSI systems/termination devices, with RJ connection For LAN interfaces (Class Ea/CAT) including PoE and ISDN S0 protection Surface-mounted flush-type socket with RJ connection Total width mm Total width mm Total width mm PE N L 8 8 PE Mains protection Data protection III / T C / C / D B / C / C C / C / D 0 V AC V DC (S 0 phantom power supply) 0 V AC (L/N-PE) V DC. V DC (±0 V DC / PoE). V DC A (0 C). A ( C). A ( C). A ( C) ka / ka 0 A /. ka 00 A / ka (per signal pair) 0 A / ka kv kv /. kv V (C ( kv/00 A)) / 9 V (B ( kv/ A) ) / 00 V (C ( kv/ ka)) 0 V / 0 V 900 V (C ( kv/ ka)) - 0 ka 0 ka 0 ka - / - 0 V / 900 V 9 V / 00 V V / 0 V - Typ. 00 khz > 00 MHz Typ. 80 MHz - C... C -0 C... 0 C -0 C... 0 C IP0 (child-proof) IP0 IP0 V0/HB - - RJ RJ Screw connection and RJ IEC - / VDE 00- / EN -/A IEC - IEC - / EN 0- / ISO/IEC 80-Am. IEC - MNT-ISDN D 88 MNT-ISDN D/WH 889 MNT-ISDN B/F 88 MNT-ISDN S/WH DT-LAN-CAT FL CAT PATCH, WT-RJ -S/ISDN/K AP For additional information, visit PHOENIX CONTACT

23 ISDN S 0 interface COMTRAB modular Plug-in module Can be used in LSA-PLUS disconnect and control strips or CT-TERMIBLOCK High transmission bandwidth Use of two CTM ISDN for one ISDN connection Connectors can be checked with CHECKMASTER Notes: Dimensional drawings starting on page 0 Approvals starting on page Attenuation curves, from page For a double wire Total width 9. mm ' ' Electrical data IEC category / EN type B / C / C / D / C Maximum continuous operating voltage U C ± V DC / - Nominal current I N. A (/ C) Nominal discharge surge current I n (8/0) μs Core-Core / Core-Ground 0 A / ka Total surge current (8/0) s 0 ka Output voltage limitation at kv/μs Core-Core / Core-Ground V / 00 V Cut-off frequency fg ( db) In a 00 system Symmetrical 00 MHz General data Temperature range - C... C Degree of protection according to IEC 09/EN 09 IP0 Inflammability class according to UL 9 V0 Connection method Can be inserted in COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and control strips Test standards IEC - Description COMTRAB modular, surge protection for the ISDN S 0 interface Magazine, with grounded rail for accommodating up to 0 LSA-PLUS protective connectors (CTM...), for insertion in CT-TERMIBLOCK or LSA-PLUS disconnect strip Screw terminal block, with disconnect contacts for accommodating the CT and CTM protective connectors, design: 0 double wires CTM ISDN 88 0 Accessories CTM 0-MAG 880 CT-TERMIBLOCK 0 DA 0 0 PHOENIX CONTACT

24 ISDN-U k0 interface Surge protection for ISDN U k0 interfaces and T/DS systems PT -TELE For ISDN U k0 and DSL applications Broadband protection for telecommunications lines D-DS-A/RJ-BB For applications with T (DS) or E data transmission protocol Connection via a keyed RJ (RJ8) female connector High transmission bandwidth Notes: Dimensional drawings starting on page 0 Approvals starting on page Attenuation curves, from page.000 Plug-in arrester with screw connection, for three conductors, with common reference potential Total width. mm 8 RJ attachment plug for two double wires Total width. mm 9 0 Electrical data IEC category / EN type C / C / C / D / B C / C / D Maximum continuous operating voltage U C 8 V DC / 0 V AC V DC / - Nominal current I N 0 ma ( C). A ( C) Nominal discharge surge current I n (8/0) μs Core-Core / Core-Ground 0 ka / 0 ka 0 A /. ka Total surge current (8/0) s 0 ka 0 ka Output voltage limitation at kv/μs Core-Core / Core-Ground 00 V / 00 V 0 V / 0 V Cut-off frequency fg ( db) In a 00 system Symmetrical Typ. 0 MHz > 00 MHz General data Temperature range -0 C... 8 C -0 C C Degree of protection according to IEC 09/EN 09 IP0 IP0 Inflammability class according to UL 9 V0 - Connection method Screw connection RJ Connection data solid / stranded / AWG 0. mm² - mm² / 0. mm² -. mm² / - - Test standards IEC - / D EN - IEC - Description DATA-PLUGTRAB, comprising male connector and base element DATATRAB, attachment plug with surge protection for T/E systems Replacement connector Patch cable, CAT, pre-assembled Labeling material ZBF..., see page PT -TELE Accessories PT -TELE-ST 88 0 D-DS-A/RJ-BB 8800 Accessories FL CAT PATCH, For additional information, visit PHOENIX CONTACT

25 Analog + DSL interface For analog and DSL telecommunications systems MNT... Compact protection for termination devices Easy operation Thermal monitoring of the protective circuit Green LED - operating indicator for the power supply MNT-TAE, with TAE connection for DSL (ADSL+) and in the ISDN network before the NTBA MNT-TELE, with RJ/RJ sockets, for telephone, modem and answering machine with a max. operating voltage of 8 V Notes: Dimensional drawings starting on page 0 Approvals starting on page Attenuation curves, from page.000 For telecommunications systems with TAE connection Total width mm / / PE N L TAE-TRAB FM-NFN For surface mounting Three TAE slots For two N-encoded and one F-encoded termination device Suitable for DSL (ADSL+) Main areas of application: Phone terminals, answering machines, modems, and fax machines WT-RJ Surface-mounted socket With -pos. RJ Western female connector Also accommodates RJ male connector Angled RJ take-up Electrical data Mains protection Data protection IEC category / EN type III / T C / C / C Nominal voltage U N 0 V AC - Maximum continuous operating voltage U C 0 V AC (L/N-PE) 00 V DC Nominal current I N A (0 C). A ( C) Nominal discharge surge current I n (8/0) μs Core-Core / Core-Ground ka / ka ka /. ka Combined surge U OC kv - Protection level U P Core-Core / Core-Ground. kv /. kv 0 V (C - ka) / 900 V (C - ka) Total surge current (8/0) s - ka Output voltage limitation at kv/μs Core-Core / Core-Ground - / - 0 V / - Cut-off frequency fg ( db) In a 00 system Core-Core - - General data Temperature range - C... C Degree of protection according to IEC 09/EN 09 IP0 (child-proof) Inflammability class according to UL 9 V0/HB Connection method RJ/TAE Test standards IEC - / IEC - EN -/A / VDE 00- Description Can be used as typical for the country MATRAB, combined surge protection adapter for inserting in a socket, for device and TAE protection Black D MNT-TAE D 888 White D MNT-TAE D/WH 889 TAE outlet box (NFN) with surge protection for analog telecommunications interfaces Surface-mounted socket D MATRAB, combined surge protection adapter for inserting in a socket, for device and TEL/TELE protection Black B, F, CZ, SVK, PL Black E, P, I, NL, LUX White S, F White N WESTERNTRAB, RJ connection socket with surge protection for analog telecommunications interfaces Surface-mounted socket, socket PHOENIX CONTACT

26 Analog + DSL interface TAE outlet box (NFN) For telecommunications systems with RJ/RJ connection Surface-mounted socket with RJ connection Total width mm Total width mm Total width mm a b E W L b N F PE N L a a L a Lb b L a N b Mains protection Data protection C / B / C III / T C / C / C C / C / C 0 V DC 0 V AC V DC 0 V AC (L/N-PE) 00 V DC 8 V DC 0 ma (0 C) A (0 C). A ( C) 0 ma ( C) ka / ka ka / ka ka /. ka. ka /. ka - kv V (C - 0 kv / ka) / 00 V (C - 0 kv / ka). kv /. kv 0 V (C - ka) / - / V (C - ka) 0 ka - 0 ka 0 ka 0 V / 0 V - / - 0 V / - 0 V / 00 V Typ. MHz - - Typ.. MHz -0 C C - C... C -0 C C IP0 IP0 (child-proof) IP0 - V0/HB - Screw connection and TAE RJ Screw connection and RJ IEC - IEC - / IEC - IEC - EN -/A / VDE 00- TAE-TRAB FM-NFN-AP 98 MNT-TEL B/F 880 MNT-TELE E 88 MNT-TELE S/WH MNT-TELE N/WH 88 WT-RJ -S/FM A/K AP 8098 For additional information, visit PHOENIX CONTACT

27 Analog + DSL interface Surge protection for analog and DSL telecommunications systems PT -TELE For analog telecommunications Two-piece, plug-in Universal use High discharge capacity Connectors can be checked with CHECKMASTER Notes: Dimensional drawings starting on page 0 Approvals starting on page Attenuation curves, from page.000 DT-TELE-RJ For analog and digital (DSL) telecommunications interface Connection: RJ female connector and/or plug-in screw terminal blocks The adapter included enables conversion from RJ to RJ and RJ (for contacting, see circuit diagram) International use thanks to multiple assignment D rail mounting possible by removing the cap Total width. mm Plug-in arrester with screw connection, for three conductors, with common reference potential 8 CTM For analog telecommunications Plug-in module Can be used in LSA-PLUS disconnect/control strips or CT-TERMIBLOCK Connectors can be checked with CHECKMASTER Electrical data IEC category / EN type C / C / C / D / B Maximum continuous operating voltage U C 8 V DC / 0 V AC Nominal current I N 0 ma ( C) Nominal discharge surge current I n (8/0) μs Core-Core / Core-Ground 0 ka / 0 ka Total surge current (8/0) s 0 ka Output voltage limitation at kv/μs Core-Core / Core-Ground 00 V / 00 V Cut-off frequency fg ( db) In a 00 system Symmetrical / Asymmetrical Typ. 0 MHz / - General data Temperature range -0 C... 8 C Degree of protection according to IEC 09/EN 09 IP0 Inflammability class according to UL 9 V0 Connection method Screw connection Connection data solid / stranded / AWG 0. mm² - mm² / 0. mm² -. mm² / - Test standards IEC - / D EN Description DATA-PLUGTRAB, comprising male connector and base element DATATRAB, surge protection for two signal pairs of the analog and digital (DSL) telecommunications interface PT -TELE COMTRAB modular Accessories Replacement connector Magazine, with grounded rail for accommodating up to 0 LSA-PLUS protective connectors (CTM...), for insertion in CT-TERMIBLOCK or LSA-PLUS disconnect strip PT -TELE-ST 88 0 Screw terminal block, with disconnect contacts for accommodating the CT and CTM protective connectors, design: 0 double wires Labeling material ZBF..., see page 8 PHOENIX CONTACT

28 Analog + DSL interface RJ attachment plug for two double wires -wire coarse protection, with failsafe contact Double wire (loop), floating Total width mm Total width 9. mm Total width 9. mm Plug RJ RJ RJ a RJ RJ RJ Plug a ' ' b a b a b b ' ' B / C / C / C / D A / B / B / B / C / C / C / D / D B / C / C / C / D 8 V DC / 0 V AC ±80 V DC / - ±80 V DC / - 80 ma ( C). A ( C) 80 ma ( C) ka / ka - / ka ka / ka 0 ka 0 ka 0 ka 0 V / 0 V - / 800 V 0 V / 800 V Typ. 0 MHz / - - / > 00 MHz 0 MHz / - -0 C... 8 C -0 C... 8 C - C... C IP0 IP0 IP0 - V0 V0 RJ/COMBICON Can be inserted in COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and control strips Can be inserted in COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and control strips IEC - IEC - IEC - DT-TELE-RJ 889 CTM X-80DC-GS 88 0 CTM X-0AC Accessories Accessories Accessories CTM 0-MAG 880 CTM 0-MAG 880 CT-TERMIBLOCK 0 DA 0 0 CT-TERMIBLOCK 0 DA 0 0 For additional information, visit PHOENIX CONTACT 9

29 Applications Description Application Protection of PROFIBUS DP or SEC L for systems with a low-resistance equipotential bonding system. This figure illustrates a protective circuit in which the cable shielding is grounded directly. XXX XXX XX XXX x x x x x x x Single-phase power supply unit Material: x PT -PB-ST (connector) x PT x-be (base element) x PT -PE/S-0AC SIEMENS S PLUGTRAB PLUGTRAB PT -PB-ST U C :, VDC I n : 0 ka PT -PE/S- 0AC-ST U C : 0 VAC I max :, ka a) RxD/TxD-P b) RxD/TxD-N c) Shield Profibus a) c) b) Profibus Protection of PROFIBUS DP or SEC L with indirect grounding of the cable shielding. If it is not possible to ground the cable shielding directly, a protective circuit must be used with the PT -HF. The shield is grounded indirectly via a diode. XXX XXX XX XXX x x x x x x x Single-phase power supply unit Note: Ground potential differences above V can cause protection to be destroyed. SIEMENS S Material: x PT -HFDC-ST (connector) x PT x-be (base element) x PT -PE/S-0AC 8 0 PLUGTRAB PT -HF- DC-ST U C : V DC I n : 0 ma 8 0 PLUGTRAB PT -PE/S- 0AC-ST U C : 0 VAC I max :, ka a) RxD/TxD-P b) RxD/TxD-N c) Shield Profibus c) a) b) Profibus 0 PHOENIX CONTACT

30 8 0 PT -HF- DC-ST 8 0 PT -HF- DC-ST 8 0 PT -HF- DC-ST Surge protection for information technology and telecommunications Applications Description Application Protection of an RS-8 interface Material: x PT -HF-DC-ST (connector) x PT x+f-be (base element) 9 9 PLUGTRAB 0 8 / T(A) / T(B) /8 R(A) / R(B) 9/0 GND / Shielding Protection of a V./RS- interface Material: x PT -HF-DC-ST (connector) x PT x+f-be (base element) 9 PAS 9 PLUGTRAB 0 8 / T(A) / T(B) /8 R(A) / R(B) 9/0 GND / Shielding Protection of a V./RS- interface Material: x PT -HF-DC-ST (connector) x PT x+f-be (base element) 9 PAS 9 PLUGTRAB 0 8 /8 TxD / RxD 9/0 GND / Shielding PAS MNT-TAE MNT-TELE MNT-ISDN PHOENIX CONTACT

Surge protection for transceiver systems

Surge protection for transceiver systems 162 PHOENIX CONTACT Surge protection for transceiver systems Main range 164 Features 166 Selection guide 168 Exposed antenna systems and outdoor cables that extend beyond a building are particularly at

More information

160 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local

160 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local 160 PHOENIX CONTACT Main range 162 Feature 164 Selection guide 166 Exposed antenna systems and outdoor cables that extend beyond a building are considered especially at risk, since they are directly exposed

More information

Surge protection for MCR technology

Surge protection for MCR technology PHOENIX CONTACT Main range Features 6 Selection guide D rail modules MCR-PLUGTRAB 90 LETRAB 0 Interfaces in MCR applications are far more sensitive to surge voltages than power supply systems. Arresters

More information

PT 3-PB-ST. Extract from the online catalog. Order No.:

PT 3-PB-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode

More information

76 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local

76 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local 6 PHOENIX CONTACT Surge protection for MCR technology Main range Feature 0 Selection guide D rail modules MCR-PLUGTRAB LETRAB 96 Interfaces in the MCR area are far more sensitive to surge voltages than

More information

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

PT 2X2-24DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 2X2-24DC-ST Order No.: 2838228 The illustration shows version PT 2x2-5DC-ST Protective plug PT with protective circuit for two 2-core floating signal circuits. Nominal

More information

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 2X2-HF-24 DC-ST Order No.: 2839729 The illustration shows the version PT 2x2-HF-12 DC-ST Protective plug PT with HF protective circuit for two 2-core floating signal

More information

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 5-HF- 5 DC-ST Order No.: 2838762 The illustration shows variant PT 5-HF-12 DC-ST Protective plug PT with HF protective circuit for 4 signal wires. Nominal voltage: 5

More information

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

TT-2-PE- 24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-2-PE- 24DC Order No.: 2838186 Modular terminal block with three-stage surge protection for a floating double conductor, separate ground connection, nominal voltage: 24

More information

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

TT-2-PE-M-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-2-PE-M-24DC Order No.: 2920641 Modular terminal block with two-stage surge protection for one operated floating double conductor, disconnect knife on both signal paths,

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

8 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

8 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 8 PHOEIX COTACT Surge protection for the power supply unit Building and industrial installations in different parts of the world have different requirements for lightning and surge protection in the power

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2013 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge arresters, type

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type

More information

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation SOCKET OUTLET (RJ5) Surge Arrester LAN fine protection for fixed installation Protection for all lines Shielded socket outlet, Category 5 Data socket outlet (Category 5) with integrated surge protection.

More information

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage

More information

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.:

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-SLKK5/ 24DC Order No.: 2794903 The illustration shows version TT-SLKK5/ 12 DC Modular terminal block with varistor as surge voltage protection between clamping connector

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 201 /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 + type 2 /7 5SD7 combination surge arresters, type 1 / type 2 /9 5SD7 surge arresters, type

More information

TT-UK5/ 24DC. Extract from the online catalog. Order No.:

TT-UK5/ 24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-UK5/ 24DC Order No.: 2794699 Modular terminal block with surge voltage fine protection between clamping connector and DIN rail, nominal voltage: 24 V DC, for mounting

More information

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 2-PE/S- 24AC-ST Order No.: 2839318 The illustration shows version PT 2-PE/S-230 AC-ST Protective plug PT with surge voltage equipment protection for power supply units,

More information

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1. PSI-MODEM-/PB Broadband PROFIBUS extender, PROFIBUS leased line modem Data sheet 104396_en_03 1 Description PHOENIX CONTACT 2013-08-21 1.1 Features The PROFIBUS extender can be used to easily network PROFIBUS

More information

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female Extract from the online catalog CN-UB-70DC-6-SB Order No.: 2803153 Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female Commercial data EAN 4046356293204

More information

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch

More information

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards Extract from the online catalog SFP 1-5/120AC Order No.: 2920667 Device surge protection filter to limit powerful surge voltages, mounting on NS 35. Commercial data EAN 4046356158558 Pack 1 pcs. Customs

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

Surge Protection for Surveillance Systems

Surge Protection for Surveillance Systems Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:

More information

BLITZDUCTOR XTU Universal lightning current / surge arrester

BLITZDUCTOR XTU Universal lightning current / surge arrester Pluggable DIN Rail Mounted SPDs Combined lightning current and surge arrester Max. discharge capacity for balanced data interfaces Capable of carrying lightning currents up to 10 ka (10/50 μs) For installation

More information

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters Lightning current and surge arresters Application-specific SPD designs SPD for use in satellite and cable TV systems with measuring output Combined lightning current and surge arrester for high discharge

More information

PSI-MODEM-SHDSL/SERIAL

PSI-MODEM-SHDSL/SERIAL PSI-MODEM-/SERIAL -SERIAL permanent line modem Data sheet 104460_en_02 PHOENIX CONTACT 2011-12-06 1 Description The industrial SERIAL permanent line modem enables broadband networking of serial devices

More information

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE

More information

S400 Series HIGH EFFICIENCY SURGE PROTECTIONS. For power supply For measurement and control devices For LAN / ICT Networks

S400 Series HIGH EFFICIENCY SURGE PROTECTIONS. For power supply For measurement and control devices For LAN / ICT Networks S400 Series HIGH EFFICIENCY SURGE PROTECTIONS For power supply For measurement and control devices For LAN / ICT Networks S400 Series High Efficiency Surge Protections High Efficiency Surge Protections

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

VAL-CP-1S-175. Extract from the online catalog. Order No.:

VAL-CP-1S-175. Extract from the online catalog. Order No.: Extract from the online catalog VAL-CP-1S-175 Order No.: 2859479 Pluggable type 2 arrester (surge arrester) for 1-phase current supply networks with separate N and PE (3-conductor system: L1, N, PE), with

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

Electrical Connection Technology. New Items: Autumn 2007

Electrical Connection Technology. New Items: Autumn 2007 Electrical Connection Technology New s: Autumn 2007 Contents Rail-Mounted Terminal Block Systems Volume 1 02 57 PCB Terminal Blocks and Connectors Volume 2 58 91 WINSTA WINSTA 93 97 Index of Nos. 98 102

More information

Surge Protection and Power Supply Units 2013 / 2014

Surge Protection and Power Supply Units 2013 / 2014 Surge Protection and Power Supply Units 2013 / 2014 6 PCB connection technology and electronics housing PCB terminal blocks and plug-in connectors Electronics housing Connection technology for field devices

More information

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage

More information

Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation. Building Connections

Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation. Building Connections Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation Building Connections Application Camera systems are used to monitor rooms, buildings and outdoor

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is

More information

PHOENIX CONTACT

PHOENIX CONTACT Fast connection connector for PROFIBUS systems Data sheet 101610_en_07 PHOENIX CTACT 2011-11-17 1 Description The D-SUB series SUBC-PLUS-PROFIB is specially designed for use in PROFIBUS systems up to 12

More information

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials Options, cables and accessories scancontrol 2x0/29x0 Options*: /SI Integrated sensor ON/OFF /PT Pigtail cable Hardware ON/OFF of the laser line 0.2m long cable directly out of the sensor /3B Class 3B /BL

More information

VAL-CP-3S-350. Extract from the online catalog. Order No.:

VAL-CP-3S-350. Extract from the online catalog. Order No.: Extract from the online catalog VAL-CP-3S-350 Order No.: 2859521 Commercial data EAN 4017918977610 Pack 1 Pcs. Customs tariff 85363030 Weight/Piece 388.83 g Product key J020 Catalog page information Page

More information

NTS-protect. Description of GPS antenna and NTS time server connection via system lightning protector system /NTS-3000, NTS-4000, NTS-5000/

NTS-protect. Description of GPS antenna and NTS time server connection via system lightning protector system /NTS-3000, NTS-4000, NTS-5000/ NTS-protect Description of GPS antenna and NTS time server connection via system lightning protector system /NTS-3000, NTS-4000, NTS-5000/ SAFETY INSTRUCTIONS! This are the important Safety Instructions

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14 Leutron Lightningand Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices Seite 0 von14 Novelties 2003 Combi Surge Protectors Leutron GmbH, 70771 Leinfelden-Echterdingen, Deutschland

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

VersaMax IP Input Module

VersaMax IP Input Module Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm

More information

CONTA-ELECTRONICS. Interface modules

CONTA-ELECTRONICS. Interface modules CONTA-ELECTRONICS allow for a passive mechanical-electrical implementation of standard connectors onto screw or tension-spring PCB terminals. The individual signals of the multi-pole or high-pole connectors

More information

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system

More information

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 454 PHOENIX CONTACT and feed-through terminal blocks The more varied the tasks in electrical engineering, the more varied the components for the solution have to be. The industrial connection technology

More information

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.

More information

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A. A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and

More information

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Easy Analog RNB130. Technical Information. Primary switched-mode power supply Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power

More information

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description Multifunctional housing for complex electronics Data sheet 105504_en_01 PHOENIX CONTACT 2013-04-08 1 Description The housings of the ME PLC 40... product group consist of a 40-mm wide housing base with

More information

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR RJ CONNECTION. DEHNlink Surge arrester

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR RJ CONNECTION. DEHNlink Surge arrester SPD X 2 No. 929 02 Line 7, V 2, ka Surge arrester Surface-mountable surge protective device for telecommunication systems Quick installation due to plug-in terminals Different types specified for interfaces

More information

2U Congestion Alert Rack Insert for UK

2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK The 2U congestion alert rack insert comes fully assembled, wired and ready to be installed in a rack. The rack provides communications,

More information

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL

More information

NEW. Phone: Fax: Web: -

NEW. Phone: Fax: Web:  - NEW 8-port unmanaged switch in IP67 Just 54 mm wide One LED per port for link / speed / data Fault relay: 1 x M12 A-coded, 5-pole (24 V DC / 1 A) 8 x M12 D-coded, 4-pole Redundant voltage supply 2 x M12

More information

DEK-OV- 5DC/ 24DC/ 3. Extract from the online catalog. Order No.:

DEK-OV- 5DC/ 24DC/ 3. Extract from the online catalog. Order No.: Extract from the online catalog DEK-OV- 5DC/ 24DC/ 3 Order No.: 2941361 The illustration shows the version DEK-OV- 24DC/24DC/3 Power optocoupler terminal block, input: 5 V DC, output: 3-30 V DC/3 A, terminal

More information

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing AUTOMATION Data Sheet 2642_en_H 1 Description PHOENIX CONT 2011-07-10 2 Features and Benefits The FL SWITCH SFNB Factoryline switches

More information

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded. Better all-round. X coded D coded 10 GBE PoE+ DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications STX M12x1 IP67 connector series With the STX M12x1 IP67 connector

More information

Data sheet C6 A modul 90 jack

Data sheet C6 A modul 90 jack Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: module, 90 cable feed solid,

More information

Surge Protective Device

Surge Protective Device Surge Protective Device LED Light / Machine protection SPD Class 2 LT-C34G801W General Information LT-C and LT-HC series Surge Protective Devices are for protection of indirect lightning. They are designed

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

B&R X67_IO_System_V3.14_E. X67 - System

B&R X67_IO_System_V3.14_E. X67 - System B&R X67_IO_System_V3.14_E X67 - System X67 I/O System - Benefits to the User Why I/Os in the IP67? Potential of the remote machine concept Cost reduction with remote I/O concept Reduced wiring Minimization

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1 Power Supply, Primary Switch Mode, arrow Design -PS-100-240AC/24/1 POWER provides: Extra narrow widths of 22.5, 45, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide range input A high

More information

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm Fieldbus System (Output device for driving port solenoid valves) Compact 8mm (Actual size) Space-saving Installation Daisy-chain wiring communication New IP67 For units with D-sub connector, and when connected

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

PLC-OPT- 24DC/230AC/1

PLC-OPT- 24DC/230AC/1 Extract from the online catalog PLC-OPT- 24DC/230AC/1 Order No.: 2900369 PLC-INTERFACE, consisting of PLC-BPT basic terminal block with Push-in connection and plug-in miniature solid-state relay, for mounting

More information

INFORMATION TECHNOLOGY SYSTEMS

INFORMATION TECHNOLOGY SYSTEMS Surge protection for INFORMATION TECHNOLOGY SYSTEMS SPDs for installations and equipment 131 Cross-reference Discontinued Products Alternatives Part No. Type Part No. Type Pluggable SPDs for DIN rail mounting

More information

Click Desktop Kit. Click Desktop Kit

Click Desktop Kit. Click Desktop Kit Click Desktop Kit Click Desktop Kit The Click Desktop Kit is a desktop-mounted set that gives you the building blocks necessary to work with your Click modules at your computer, whether you re testing

More information

Lightning and Surge Arresters

Lightning and Surge Arresters Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement

More information

Surge protection for telecommunication connections

Surge protection for telecommunication connections Surge protection for telecommunication connections White Paper Contents Lightning and surge protection for an analogue connection with ADSL Lightning and surge protection for an ISDN connection with ADSL

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

Module no: LabelId: Operator:Phoenix 14:20:45, Mittwoch, 1. März 2000

Module no: LabelId: Operator:Phoenix 14:20:45, Mittwoch, 1. März 2000 PLC-O M 8 "...6" Equipped with pluggable miniature optical coupler Terminal width 6.2 VDE, UL, CSA applied for (IEC) [mm 2 ] Connection data rigid solid 0.14-2.5 flexible stranded 0.14-2.5 AWG 26-14 I

More information

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.: Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration

More information

Project information sheet

Project information sheet Customer data: Company: Name: Phone: E-mail: Project und Anschrift des zu planenden Objektes: (unbedingt angeben) Project name: Lightning protection system / LPL installed external lightning protection

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

PAS 300, PROFIBUS Slave Interface Module

PAS 300, PROFIBUS Slave Interface Module Catalog 08 PROFIBUS-Components 27 PAS 300, PROFIBUS Slave Interface Module PROFIBUS PROFIBUS slave interfaces PROFIBUS slave module The PROFIBUS slave interface module PAS 300 from the Systeme Helmholz

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray Features: Connects 75 ohm coaxial and 120 ohm twisted pair cabling systems Supports all G.703 data rates up to 34 Mbps Snap-in modules are easy to install and maintain Field expandable and upgradable Various

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

M12x1 Circular Connectors

M12x1 Circular Connectors M12x1 Circular Connectors Agenda 1. Introduction M12x1 Circular Connectors 2. M12x1 X-coded 3. M12x1 D-coded 4. Accessories and Nomenclature 3 / 2015 Product Presentation M12x1 Page 2 M12x1 Circular Connectors

More information

VersaMax IP I/O Module

VersaMax IP I/O Module Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)

More information

New Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications

New Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications New Product Bulletin PB 327 Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications These 16 digital I/O channels with universal input/output functionality for direct connections

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

ECL Comfort 296 / 310 controllers Modbus networking guide

ECL Comfort 296 / 310 controllers Modbus networking guide Service Guide ECL Comfort 296 / 310 controllers Modbus networking guide 1.0 Contents 1.0 Contents......1 2.0 Introduction...2 3.0 Conclusion...2 4.0 Modbus network definitions...3 4.1 Multipoint serial

More information

Manual Fiber Optic Interfaces

Manual Fiber Optic Interfaces Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it

More information

MGate 4101-MB-PBS Series

MGate 4101-MB-PBS Series MGate 4101-MB-PBS Series 1-port Modbus RTU/ASCII-to-PROFIBUS slave gateways Features and Benefits Protocol conversion between Modbus and PROFIBUS Supports PROFIBUS DP V0 slave Supports Modbus RTU/ASCII

More information