1 bar N L Switch B Switch A Dry Contact - Installation Guide This installation guide is for dry contact switches and their connectivity with home automation, building management systems and stand alone automation applications. This example shows a single group of 4 actuators which are not controlled individually. The control panel has 4 RQ units and a 20A power supply. We recommend the following wiring method which allows for less wiring and a minimal chance of installation error. This layout requires 1 PSIB for communication with a Building Management System and a separate PSIB for communication with a momentary SPDT (Single Pull Double Throw) switch. BMS DRY CONTACT 5 Amp fuses -32V DC +V +V -V -V 110 VAC POWER SUPPLY PSIB BUS AUX ACC ACC ground Source 1 Externally Supplied 110 VAC Use Copper Conductors Only Rated 60 C (140 F) CP-4RQ- 20A.DC-UL A1 L1 B1 SWITCH B SWITCH A ACC ACC AUX BUS PSIB For reference only - not project specific. SW5657 SWITCH C PLEASE NOTE 1. All connections to the control panel should be made prior to powering up. 2. Polarity matters! Polarity between the actuators and the control panel to your BMS/FMS is essential in order for everything to work properly. 3. If you have any questions, please call FFI at or sales@fenestration.net Copyright 2014 FFI Page 1 of 7
2 Dry Contact - Installation Guide This example shows 3 actuators which are controlled individually. The control panel has 3 RQ units and a 20A power supply. We recommend the following wiring method which allows for less wiring and a minimal chance of installation error. This layout includes communication between a Building Management System and the automation control panel. BMS open common close F - Signal w/ F-Signal w/ F-Signal w/ F-Signal 5 Amp fuses -32V DC +V +V -V -V 110 VAC POWER SUPPLY N L ground bar Source 1 Externally Supplied 110 VAC Use Copper Conductors Only Rated 60 C (140 F) CP-3RQ- 20A.DC-UL DRY CONTACT NOTE: CABLE THAT IS REQUIRED FOR CONNECTIONS IS TO BE PROVIDED BY OTHERS. For reference only - not project specific. Copyright 2014 FFI Page 2 of 7
3 FFI control panel containing a power supply and controller Do not add non-essential components or disconnect internal wires or components! System Example: Three DC actuators with FFI control panel with power supply and 3 RQ units, IR or RF receiver and transmitter, PSIB and momentary contact switch. For reference only - not project specific. PSIB accessory can be used in many instances, it is used more often when there are 2 or more RQ s. Diagram elements are not to scale. Copyright 2014 FFI Page 3 of 7
4 RQ ler Connections The white label on top of the RQ controller card indicates where all of the connections are located on the RC controller. The white label shows where to find the connections for the following: The QAUX and QEYE ports The dry contacts for OPEN, COMMON, and CLOSE The actuator connections (MOT) and power connections (NEG and POS) Note: Do not tamper with these, as they are pre-wired for every control panel Important: The label may be in any of four orientations as you look at it. The orientation can change depending on the design of the control panel containing the RQ controllers. Please pay close attention to each RQ controller to be certain you are connecting to the correct contacts. The QAUX and QEYE ports are particularly important to connect correctly, as it can be easy to confuse the two. Below are examples to illustrate this. The white label may have different orientations as you look at different RQ controllers, as shown below. The white label indicates the location of the connections on the particular RQ controller, as shown below. Connect only at orange arrow points; do not tamper with other wiring or components. Copyright 2014 FFI Page 4 of 7
5 Dry Contact Switch, Maintained: Double Pole Double Throw (DPDT) SW5686-2W Maintained Switch Dry Contact Switch, Maintained: Single Pole Single Throw (SPST) Maintained contact switch with key SW.CK-KEY-02 Optional Accessories PSIB - Programmable Switch Interface in a Box Can be used to connect a group of FFI actuators to a local switch and bypass a central BUS command. Allows fewer wire runs, with decentralized control. Copyright 2014 FFI Page 5 of 7
6 Installing switches Dry Contact Switch, Momentary: Single Pole Double Throw (SPDT) Warning! Do not apply voltage to the dry contact s. SPDT switch connection to a controller SW5657-2W Momentary Switch KL Momentary Switch with Key 1257-L Momentary Switch with Key Copyright 2014 FFI Page 6 of 7
7 Troubleshooting Questions? Troubleshooting? Call FFI at PLEASE NOTE! 1. All connections should be made prior to powering up. 2. Polarity matters! Polarity between the actuators and the control panel to your BMS/FMS is essential in order for everything to work properly. 3. If you have any questions, please call FFI at or (1) Always test your data cables Use a cable tester to check all cables connected to the card and control panel. For more details, see FFI Cables Data Sheet. (2) Test for power Check that the controller card is getting power. The controller card has a green LED that lights up briefly when it receives a command. Each RQ unit will flash a Red, Red, Green sequence to indicate power and connectivity. LED Indicator (3) Test for continuity with a multi-meter Use a multi-meter to check the continuity between the power supply and the terminal block(s). As shown on diagram 9c, touch the multi-meter to the screw-heads on the power supply and each terminal block in the control panel as indicated by the arrows. Test for continuity between the negative connections, then test for continuity between the positive connections. If you find a continuity problem, next test the fuse by probing at each end of the fuse. Fuse Power Supply Block (4) Do not add non-essential components or disconnect internal wires or components! (5) The FFI Field Power Switch is available for use with FFI DC actuators, for testing and installation. FFI Field Power Switch Part # SW.FPS.01 (6) Contact FFI for assistance. Recommendations for FFI Actuators & s: FFI only recommends UL compliant systems. FFI is a UL Registered firm. Read FFI data sheets & installation guides before specifying project details. Project-specific needs vary depending on the number of actuators, electrical layouts, building management systems, distance between power supplies & actuators, and other details. Project specifications to comply with electric & building codes for wire gauge, wire connections and run distance, conduits, junction boxes must be arranged by the project electrical contractors. Distribute this guide to all project parties, including electric contractors, architects and building management personnel! Copyright 2014 FFI Page 7 of 7
Stand Alone Actuator Systems
Stand Alone Actuator Systems Installation Guide for FFI Actuator Projects This installation guide is for FFI actuators and power supplies that are not connected to building management or home automation
More informationHome Automation Systems Installation Guide for FFI Actuator & Control Projects
Home Automation Systems Installation Guide for FFI Actuator & Control Projects This installation guide is for home automation systems such as Crestron, Lutron and others which communicate with FFI controllers
More informationRB24 Relay Box Installation Guide For use in low voltage motorized window and skylight systems
RB24 Relay Box for 24 VDC motors part # 40995J Wire access ports Applications A Relay Box acts as an interface between FFI actuators and Direct Digital Control (DDC) systems such as Building Automation
More informationCRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)
CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Applications CRM includes a control relay box and a power supply; additional
More informationQUASAR Installation & Maintenance Guide motorized actuator for windows and skylights
Functional Fenestration Inc (FFI) Quasar Actuator Application Options On Wall or Frame Awning Skylight Hopper Concealed in Frame or Curtain Wall CAD files available on request from FFI. Optional brackets
More informationDTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A
DTS 310 DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter Page 1 1 PRODUCT OVERVIEW... 3 1.1 SUPPLIED ITEMS... 3 1.2 DOCUMENT CONVENTIONS... 4 1.3 PRODUCT SPECIFICATION... 4 1.3.1 Current
More informationCatalog Number Identification with Elements Explained V V V V X 347 V Hz
Owner s Manual 917 & 918 Remote Control Switches TABLE OF CONTENTS page Ratings & Installation... 1 2 Optional Accessories... 3 4 Troubleshooting & Parts Kits... 5 Wiring & Outline Diagrams... back of
More informationUser's Guide. Model W 3-in-1 Switching DC Power Supply
User's Guide Model 382260 80W 3-in-1 Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 80W 3-in-1 Switching DC Power Supply. The Model 382260 has three output ranges
More informationOccupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE
Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE 2 Part Number: WIR-3110 WARNING! SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODES
More informationD6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D
D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General
More informationPO Box 409 Hanover, MD TEL (410)
ME-50 Expansion Amplifier 1 ME-50 Expansion Amplifier Introduction: The ME-50 is a 2 channel audio amplifier capable of delivering up to 25W RMS per channel. It s compact, waterproof design allows for
More informationA0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Document Number: 9100-127-2301-99 Release Date: 2/2/15 A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS DO NOT let any supply cords touch hot surfaces higher
More informationControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet
General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.
More informationPV Rapid Shutdown device
PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.
More informationIf I wanted to connect an LED and little light bulb and have them switch on and off with one switch, my schematic would look like the one below.
Relays Relays are great tools for turning on and off entire circuits, either with a small control switch, or with a microcontroller like the Arduino. To understand how relays are useful and how to control
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More information9212i INSTALLATION. Stand-Alone Keypad. Instructions
INSTALLATION 9212i Stand-Alone Keypad Instructions Features: 4 Independent Outputs 4 Independent Timers All Outputs Assignable by Code On board 5 Amp Form C Relay 120 Users Remote Triggering Input Keypad
More informationIntegrated Battery Control System LBCS Step-by-Step Setup Guide
Integrated Battery Control System LBCS Step-by-Step Setup Guide 1. Components of the System 2. Components of the System 3. LBCS Overview 4. Battery Connections 5. Sense Board Installation 6. Sense Board
More informationMODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS
MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It
More informationKeypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual
secure open Keypad CT Art. No.:, (black) Art. No.:, (white) Installation Manual CT_installation_ENGmay Conlan ApS Speditorvej A DK- Aalborg Tel: + Fax: + www.conlan.eu info@conlan.eu Table of contents.
More informationOverview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.
LX Breaker Control Panels Installation and Setup Procedure Hubbell Building Automation, Inc. 9601 Dessau Road Building One Suite 100 Austin, Texas 78754 512-450-1100 512-450-1215 Fax www.hubbell-automation.com
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationIQ-SBS LCU Series Installation Instructions
Installation Instructions LCU-1 The IQ-SBS LCU-1 is a self-contained device for integrating control of facility lighting with IQ-SBS. The LCU-1 controls lighting zones, accepts input from override switches
More informationINSTALLATION INSTRUCTIONS
TT-568 /a INSTALLATION INSTRUCTIONS Original Issue Date: 2/ Model: 4/20RES and 4/20RESL Generator Sets Market: Residential/Commercial Subject: RDC and DC Controller Replacement Kits GM79884 and GM79885
More informationLXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual
LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic
More informationMAXIMA+ Series Rotary Level Indicator
MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE
More informationInstallation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2
Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3
More informationInstruction Manual. M Pump Motor Controller. For file reference, please record the following data:
Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationLiteKeeper 8. Stand Alone Lighting Control Panel Technical Specifications PART 1. GENERAL 1.01 INTRODUCTION 1.02 DESCRIPTION OF WORK
LiteKeeper 8 Stand Alone Lighting Control Panel Technical Specifications PART 1. GENERAL 1.01 INTRODUCTION The work covered in this section is subject to all of the requirements in the General Conditions
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A
More informationPower Supply Installation
Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial
More informationP M C L O G I C. 10 Inputs High-side or Low-side /110 PMC 10 Channel Input Module. PMC Input Module 110
10 Inputs High-side or Low-side 00-00622-100/110 PMC 10 Channel Input Module PMC Input Modules 100 and 110 are members of Intellitec's Programmable Multiplex Control family. They work in combination with
More informationINSTALLATION WIRE DIAGRAMS UR2A/4A UNIVERSAL ACCESS HARDWARE CONTROLLER. Features. All Twelve (12) Inputs of the UR4A are Optically Isolated.
Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION WIRE DIAGRAMS UR2A/4A UNIVERSAL
More informationExpandable Power Systems
Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.
More informationEvolution Variable Output. With Override Pot. Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL 35033
Evolution Variable Output With Override Pot, Inc. 1733 Co Rd 68 PO Box 99 Bremen, AL 3033 Part No. 4801318 Rev 703 Owners Manual Evolution Variable Output Table of Contents Section Title Page 1. Warranty...3
More informationModel# CKM18 Model# CKM36 Model# CKM48 WARNING
Installation Instructions Model# CKM18 Model# CKM36 Model# CKM48 WARNING HAZARDOUS VOLTAGES. DISCONNECT FROM SUPPLY BEFORE REMOVING COVERS. NO USER SERVICEABLE PARTS INSIDE. SERVICE BY QUALIFIED PERSONNEL
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationInstallation Quick Reference Guide. BACnet Alarm v1.0
Installation Quick Reference Guide BACnet Alarm v1.0 Contents User Responsibility 4 Introduction 5 Features 5 Description of BACnet Alarm 5 Shipment Details 5 The BACnet Alarm Back Box 5 The Frame Assembly
More informationDual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02
Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 User Manual 1.1 Overview Telect s 80A, -48 Vdc Low-Voltage Disconnect (LVD) panel is a rack-mounted component with coil-operated contactors. These
More informationLearning to Use a Voltage Probe
Learning to Use a Voltage Probe Computer 40 A Voltage Probe can measure the voltage of a battery. This is one way of checking whether a battery is good. In this activity, you will learn about the Voltage
More informationUniversal Safety Photo Eye UL MONITORED DEVICE
IRB-MON Universal Safety Photo Eye UL325-2016 MONITORED DEVICE Operating Instructions CAUTIONS AND WARNINGS This product is an accessory or part of a system. Always read and follow the manufacturer s instructions
More informationStarzone 4000 Master Control Panel Figure 2.1 Master Control Panel
Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel The heart of the Starzone 4000 system is the Starzone Master controller (SZM-4000). Each AHU that is to be zoned will have its own SZM-4000
More informationBLU- CIF Interface Board
BLU- CIF Interface Board The BLU-CIF Interface Board simplifies the wiring of all of the BLU products to the BSS Audio London Series Digital Signal Processors. It allows for Cat5e wiring termination, as
More informationVG-305A AC Traffic Light Controller Kit
Galak Electronics Electronic kits and components Website: GalakElectronics.com Email: sales@galakelectronics.com Phone: (302) 832-1978 VG-305A AC Traffic Light Controller Kit Thank you for your purchase
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS WARNING To reduce the risk of death, injury or property damage from fire,
More informationInstallation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE
IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL
More informationOPERATING INSTRUCTIONS AND SERVICE MANUAL BASKETBALL SHOTCLOCK MODEL MP-5299
OPERATING INSTRUCTIONS AND SERVICE MANUAL BASKETBALL SHOTCLOCK MODEL MP-5299 EFFECTIVE S.N. 17,000, December, 2000 TABLE OF CONTENTS 1. General Information 1.1 Description 1.2 Identification 1.3 Damage
More informationUNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN
1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,
More informationINSTALLATION INSTRUCTIONS Model 930 EntryCheck
SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck
More informationDraper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
More informationVCM Systems Vehicle Control Module Systems
VCM Systems Vehicle Control Module Systems Technical Manual VCMS-SC (Standard Configuration) Switch Panel System The Model VCMS-SC Switch Panel System is a standard configuration of the VCMS product family
More informationPQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES
CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual Q45 230V ac Control panel for electric rolling shutters 230Vac Built-in radio receiver 433Mhz Adjustable pause time for automatic closing function
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS
LRC0 8X0A Relay Control Panel BACnet MS/TP Enabled INSTALLATI INSTRUCTIS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS!
More informationAirTest Model CN9000 Series Sensor Controller
AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay
More informationLine Voltage Switching Hardwired (Direct Wiring)
Line Voltage Switching Hardwired (Direct Wiring) Motorola Cellular Subscriber Facility, IL Globetrotter s Engineering Architects MechoShade possesses a variety of Line Voltage Switches for basic control
More informationLiteKeeper 4. Stand Alone Lighting Control Panel Technical Specifications PART 1. GENERAL 1.01 INTRODUCTION 1.02 DESCRIPTION OF WORK
LiteKeeper 4 Stand Alone Lighting Control Panel Technical Specifications PART 1. GENERAL 1.01 INTRODUCTION The work covered in this section is subject to all of the requirements in the General Conditions
More information1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882
1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature
More informationWARNING 25.2 POWER L.V X1 X2 Y0 C1 Y1 C2 Y2 C3 Y3 ELC-EX NN. 3. Extension unit clip 4. Input/output terminal
POWER L.V 006--7 506000-E ELC-ENNDR/T ELC-E6NNDR/T ELC-ENNDN ELC-ENNAN ELC-ENNNR/T ELC-E6NNNI Instruction Sheet Digital Input Digital Output Module WARNING This Instruction Sheet provides descriptions
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)
ga GE Digital Energy Power Quality INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs) 2020005003 (12/09) Page 1 of 18
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 TABLE OF
More informationEnergy Meter and. Current Transducer. Assembly Manual
Energy Meter and Current Transducer Assembly Manual 2017 1 The energy meter assembly is made of two separate boxes and associated accessories, as follows: Energy Meter (EM) Box, with two cables feeding
More informationNext Gen Sarix Enhanced IBE Series Bullet Cameras
Next Gen Sarix Enhanced IBE Series Bullet Cameras Installation Manual C1334M 12/16 1 Contents Important Notices... 3 Regulatory Notices... 3 Radio and Television Interference... 3 Korean Class A EMC...
More informationAMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES
Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Two cards providing 8 channels of temperature and process monitoring for VM 600 systems 8 channels of software selectable
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS WARNING To reduce the risk of death, injury or property damage from fire,
More informationIXIAN. Reads. Range / Accuracy. Calibration. 1, 2, 3 point remotely through PLC or directly on board.
V 3.0 Revised 12/13/17 ph IXIAN Transmitter Reads ph Range.001 14.000 Accuracy Calibration Supported probes Temp probe +/ 0.002 1, 2, 3 point remotely through PLC or directly on board Any type & brand
More informationRSTI-EP Slice I/O Digital Input Modules EP-1214, EP-1218, EP-1318, EP-125F, EP-1804 Digital Input Module with Time Stamp EP-12F4
GFK-2975C August 2016 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Digital Input Module RSTI-EP Slice I/O Digital Input Modules EP-1214, EP-1218, EP-1318, EP-125F, EP-1804
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationSECTION DISCONNECT SWITCHES
SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationpoly-planar Marine Audio System
ME-52 Expansion Amplifier 1 ME-52 Expansion Amplifier Introduction: The ME-52 is a 2 channel audio amplifier capable of delivering up to 25W RMS per channel. It s compact, water resistant design allows
More informationModular Room Control (MRC) Series Expansion Board
Installation Instructions Issue Date December 13, 2002 Modular Room Control (MRC) Series Expansion Board Application The Modular Room Control (MRC) system has the ability to expand its input/output capabilities
More informationSoundwebTM. Installation Guide
111 SoundwebTM Soundweb TM 9010 Installation Guide Soundweb TM Regulatory Information v1.0 PW/JMK 21st March 1999 An example of this equipment has been tested and found to comply with the following European
More informationE-Series General Specifications
-Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire
More informationInstallation, Operation and Maintenance Manual
Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationS-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter
S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter
More informationProduct description Rev. 3 11/06/14
EZ863-2G - GNSS Product description Rev. 3 11/06/14 1 Table of Contents 1. Overview... 4 2. General Description... 4 2.1 Dimensions... 4 2.2 Weight... 4 2.2 Installation... 5 2.3 Casing material... 6 2.4
More informationMCU-9201MT22 venetian blind controller
MCU-9201MT22 venetian blind controller It is strongly recommended to read and follow the instructions in this manual carefully, before you start installing or programming a system. Installation, configuration
More informationICP-SDI Installation Instructions. SDI Splitter
ICP-SDI-9114 EN Installation Instructions SDI Splitter ICP-SDI-9114 Installation Instructions Listings and Approvals Listings and Approvals UL UL 65 Police Station Burglar Alarm Units and Systems UL 609
More informationK10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual
K0 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual Pneumatic Connection Single Acting Actuator (Spring Return): For single acting actuators Outlet Port 2 is to be plugged. Outlet Port
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationWiring and Configuration Instruction
Wiring and Configuration Instruction This ENVIROMUX Sensor is intended for connection to an NTI ENVIROMUX-MINI-LXO /-16D / -5D/-2D for use in detecting changes in the environment. When properly connected,
More informationOPERATING INSTRUCTIONS AND SERVICE MANUAL 4000 SCOREBOARD CONVERSION. TO PLAY WITH 5000 SCOREBOARD and CONTROL
OPERATING INSTRUCTIONS AND SERVICE MANUAL 4000 SCOREBOARD CONVERSION TO PLAY WITH 5000 SCOREBOARD and CONTROL EFFECTIVE S.N. 17,500, November 28, 2001 TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1 DESCRIPTION
More informationAlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s)
AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s) APPLICATION The AlphaStatus system allows one or more RSS402, RSS403,
More informationWatchman Entry System
Watchman Entry System Installation Guide Portal User Name Password The Watchman Entry System is the newest product from CellGate. Watchman is meant to be an easily installed self-contained gate or door
More informationInk-Dot Series II Driver
Instruction Sheet P/N 766B Ink-Dot Series II Driver Introduction See Figure. Ink-Dot Series II controllers can have from one to three driver modules. Any existing controller can easily be retrofit with
More informationIRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE
O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884
More informationWIRING INSTRUCTIONS FOR HENRY SIGNS CONCERNING THE JOHN HANCOCK SIGN
WIRING INSTRUCTIONS FOR HENRY SIGNS CONCERNING THE JOHN HANCOCK SIGN Enclosed are the steps to a successful install of this project ALDOR Electronic Services 2961 Industrial Rd. Ste. #212 Las Vegas, NV
More informationPart No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A
Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.
More informationBLU- CIF Interface Board
BLU- CIF Interface Board The BLU-CIF Interface Board simplifies the wiring of all of the BLU products to the BSS Audio London Series Digital Signal Processors. It allows for Cat5e wiring termination, as
More informationExercise 2. Switches EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Introduction to switches. Switch types
Exercise 2 Switches EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the operation of switches. You will be introduced to the various types of switches and to the various
More informationQuick Start Installation Guide
RM-DCM-2 Quick Start Installation Guide Version G0 Document Part Number UM-215 May 2010 OVERVIEW The RM-DCM-2 is a UL294 Listed and UL1076 Listed door control module that includes the RM-4E Reader Module
More informationInstallation Instructions 4291 and 4292 Keypads
Installation Instructions 4291 and 4292 Keypads A6851J 02/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the
More informationOutput Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W
Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the
More informationSureTest Model ST 1D Instructions
#61-152 #61-153 SureTest Model ST 1D Instructions Introduction The SureTest family of circuit analyzers identify problems common to electrical circuits quickly, easily and accurately. They have a patented
More informationOPERATING INSTRUCTIONS AND SERVICE MANUAL. MODEL MP-3804 BLACK FLAG DISPLAY WITH MP-2002 Control
OPERATING INSTRUCTIONS AND SERVICE MANUAL MODEL MP-3804 BLACK FLAG DISPLAY WITH MP-2002 Control EFFECTIVE S.N. 18,959 May 2, 2003 TABLE OF CONTENTS 1. General Information 1.1 Description 1.2 Identification
More informationSERIES CMT CARBON MONOXIDE GAS TRANSMITTER
SERIES CMT CARBON MONOXIDE GAS TRANSMITTER INSTALLATION OPERATION AND MAINTENANCE MANUAL DWYER INTRUMENTS, INC. PO BOX 373, MICHIGAN CITY, IN. 46360 USA PHONE: 800-872-9141 FAX: 219-872-9057 Web: www.dwyer-inst.com
More informationAD-7830 Servo Amplifier
Instruction Manual IM-0606 AD-7830 Servo Amplifier Table of Contents General Information... 2 Introduction... 2 Receiving/Inspection... 2 Storage... 2 Equipment Return... 2 Abbreviations Used in This Manual...
More information12 MODULE BAR ASSEMBLY INSTRUCTIONS EL3H12AØØ(x)
ASSEMBLY INSTRUCTIONS MOUNTING INSTRUCTIONS Before starting the installation make certain you have the correct bracket for your application. A universal Deck/Dash mount bracket is supplied. For other mounting
More information