IRT Eurocard Type. DVA Mb/s ASI/SDI 8 O/P Reclocking Distribution Amplifier

Size: px
Start display at page:

Download "IRT Eurocard Type. DVA Mb/s ASI/SDI 8 O/P Reclocking Distribution Amplifier"

Transcription

1 I R T Electronics Pty Ltd A.B.N Hotham Parade, ARTARMON N.S.W. 064 AUSTRALIA National: Phone: (0) Fax: (0) International: sales@irtelectronics.com Web: IRT Eurocard Type DVA Mb/s ASI/SDI 8 O/P Reclocking Distribution Amplifier Designed and manufactured in Australia IRT can be found on the Internet at: dva.ib.doc Page of 9 6/0/00

2 DVA Mb/s ASI/SDI 8 O/P Reclocking Distribution Amplifier Instruction Manual Table of Contents Section Page Operational safety Description Specifications 4 Technical Description 5 Installation 5 Front & rear panel connector diagrams 7 Maintenance & storage 8 Warranty and service 8 Equipment return 8 Drawing index 9 This instruction manual applies to DVA-007 later than S/N Operational Safety: WARNING Operation of electronic equipment involves the use of voltages and currents that may be dangerous to human life. Note that under certain conditions dangerous potentials may exist in some circuits when power controls are in the OFF position. Maintenance personnel should observe all safety regulations. Do not make any adjustments inside equipment with power ON unless proper precautions are observed. All internal adjustments should only be made by suitably qualified personnel. All operational adjustments are available externally without the need for removing covers or use of extender cards. 007-dva.ib.doc Page of 9 6/0/00

3 Description BLOCK DIAGRAM DVA-007 SIGNAL PATH (Optional ZDA-006RL Bypass Rear Assembly) (Number of outputs reduced to 6) O/P O/P O/P O/P 4 INPUT EQUALISER RECLOCKING SIGNAL FAIL DETECTION O/P 5 O/P 6 O/P 7 O/P 8 MON O/P LINK Relay RL = Output Alarm RL RL ALARM O/P The DVA Mb/s serial digital video distribution amplifier provides the user with a single standard module to cover a wide range of distribution and monitoring functions for SDI or ASI signals. Due to the fact that standard loop through techniques used in the analogue domain are unsuitable to the digital domain most digital equipment comes with no facility to route the input signal to other locations. As a result a VDA is required at almost every point in the digital chain. Serial digital signals also suffer severe deterioration over relatively short cable distances. The DVA-007 provides a means of extending the working distances that can be achieved by equalising, reclocking and re-transmitting the data mid route. Where a large number of reclocked outputs are required the DVA-007 may be used to provide reclocking and its outputs fed to one or more DVA-006 non reclocking DA s to provide the number of outputs required. This provides a more economic solution than using multiple reclocking DA s and minimises jitter increase due to unnecessary re-clocking. An optional rear assembly, ZVA-006RL (sold separately), provides a bypass relay to switch the Input (SK) to Output (SK) in the event of a power failure. When this bypass rear assembly is used, the number of outputs is reduced to 6. The DVA-007 may be mounted in IRT s RU or RU frames with other analogue or digital modules. Features: For use as buffer or distribution amplifier. 8 x in-phase 70 Mb/s ASI or SDI reclocked outputs. Automatic input equalisation to 50 metres. Automatic output muting on no input. May be used in conjunction with non-reclocking DA s to provide multiple reclocked outputs. Front panel indicators provide monitoring of presence of input signal at 70 Mb/s. 007-dva.ib.doc Page of 9 6/0/00

4 Technical Specifications DVA-007 Video input: Number. Impedance 75 Ω. Return loss >0 db 5 MHz to 70 MHz. (>5 db with optional ZVA-006RL bypass rear assembly) Equalisation Automatic, better than 50 metres at 70 Mb/s for Belden 88 or equivalent cable. (reduces to 00m when LK is closed). Video outputs: Number 8 ASI or SDI plus one front panel monitoring output. Type Reclocked. Level 800 mv ±0% into 75 Ω. Impedance 75 Ω. Return loss >0 db 5 MHz to 70 MHz. DC offset Performance: Reclocking Rise time Residual jitter Connectors: (>5 db with optional ZVA-006RL bypass rear assembly) Nil. Factory set for 70 Mb/s operation. <.0 ns, (700 ps typically). <0. UI (measured with up to 00m of Belden 88 or equivalent cable). BNC 75 Ohms. Indicators: Power LED (green) for +5 V. Signal present LED (green) when valid ASI/SDI signal present. Alarm: Signal loss Power requirement: Voltage Consumption Contact closure. Link selectable NO/NC. 8 Vac CT (4-0-4) or ±6 Vdc.5 VA (including ZVA-006RL optional rear assembly). Other: Temperature range 0-50 C ambient. Mechanical Suitable for mounting in IRT 9" rack chassis with input, output and power connections on the rear panel. Finish: Front panel Grey background, black lettering & red IRT logo. Rear assembly Detachable silk-screened PCB with direct mount connectors to Eurocard and external signals. Dimensions 6 HP x U x 0 mm IRT Eurocard. Standard accessories Rear connector assembly with matching connector for alarm output. Optional accessories ZVA-006RL relay bypass rear assembly (6 O/P). Due to our policy of continuing development, these specifications are subject to change without notice. 007-dva.ib.doc Page 4 of 9 6/0/00

5 Technical Description The input circuit of the DVA-007 consists of an adaptive cable equaliser IC, which automatically adapts to equalise any cable length from zero metres to lengths that attenuate the signal by 40 db at 00 MHz. This corresponds to 00 metres of Belden 88 cable. When link LK is closed equalisation is reduced to 00m for use in noisy environments or when a short cable is used. A carrier detect and output mute circuit is used to mute the output when no signal is present. The DVA-007 is insensitive to the pathological patterns that can be present in the serial digital video signal. The DVA-007 also features an OUTPUT MONITOR point on the front panel. The output monitor is an isolated copy of the signal present at the rear panel outputs. The output of the input stage is coupled to reclocking circuit, which then feeds cable driver circuits to provide the eight isolated in phase outputs from the DVA-007. The input cable equaliser circuit U and reclocking circuit U incorporate carrier detection circuits to mute the output when no signal is applied to the unit. The carrier detect signal and lock signal of U are used to energise relay, RL via a transistor, Q, when locked carrier is present. The relay contacts are connected to SK0 on the rear panel to give a failure alarm in the form of a make (or break) to ground on failure as set by a link LK, on the circuit board. The dual AC inputs are rectified and then regulated by a switch mode regulator circuit to provide the operating voltage for the unit. dc is fed to pin a of the rear Euro-connector via a polyfuse, JP. The is to provide power for a signal bypass relay on the optional ZVA-006RL bypass rear assembly, should one be used. The polyfuse protects the power rail by going high impedance should pin a be shorted to ground. This protects against the accidental insertion of the DVA-007 in anything other than its standard rear assembly or the optional ZVA-006RL rear assembly. Handling: Installation The DVA-007 contains static sensitive devices and proper static free handling precautions should be observed. When individual modules are stored, they should be placed in antistatic bags and proper antistatic procedures should be followed when inserting and removing cards from these bags. Power: Ensure that the voltage selection of the IRT mounting frame used to house the DVA-007 and the local AC mains supply voltage match and that the correct rating fuse is installed in the mounting frame power supply. Earthing: Chassis earth connection of the equipment mounting frame is via the earth connection on the three pin (IEC) AC mains supply inlet. This is a safety earth and must be connected. Installation in frame or chassis: See details in separate manual for selected frame type. LK is factory set for a contact make to ground on signal failure at SK0 pin on the rear panel, move LK from the normally closed (N/C) to the normally open (N/O) position for a break to ground on signal or power loss. Link LK closed reduces the input equalisation to 00m for use in noisy environments or when a short input cable is used. The presence of 70 Mb/s locked signal is indicated by the SIGNAL PRESENT front panel LED (green). The presence of the internal +5 Vdc supply is indicated by the front panel LED (green). 007-dva.ib.doc Page 5 of 9 6/0/00

6 It is recommended that unused outputs on the rear panel be terminated with 75-ohm termination plugs. 007-dva.ib.doc Page 6 of 9 6/0/00

7 Front & rear panel connector diagrams The following front panel and rear assembly drawings are not to scale and are intended to show relative positions of connectors, indicators and controls only. Optional bypass relay rear assembly DVA O/P ASI/SDI D.A. ZVA-006RL 6 O/P ASI/SDI D.A POWER OFF BYPASS SK-SK. SK9 SK7 SIGNAL PRESENT SK7 SK8 SK5 SK6 SK6 SK4 SK5 SK SK4 SK OUTPUT MON DC SK SK SK INPUT SK0 SK0 = Alarm SK0 = Gnd RLR SK INPUT SK0 SK0 = Alarm SK0 = Gnd N40 Note that the ZVA-006RL is an optional relay bypass rear assembly (sold separately), which bypasses the input direct to output in the event of a power failure. This optional rear assembly is only compatible with both the DVA-006 and DVA-007 ASI distribution amplifiers and not the previous ASI/SDI distribution amplifiers, DVA-00 to DVA dva.ib.doc Page 7 of 9 6/0/00

8 Maintenance & storage Maintenance: No regular maintenance is required. Care however should be taken to ensure that all connectors are kept clean and free from contamination of any kind. This is especially important in fibre optic equipment where cleanliness of optical connections is critical to performance. Storage: If the equipment is not to be used for an extended period, it is recommended the whole unit be placed in a sealed plastic bag to prevent dust contamination. In areas of high humidity a suitably sized bag of silica gel should be included to deter corrosion. Where individual circuit cards are stored, they should be placed in antistatic bags. Proper antistatic procedures should be followed when inserting or removing cards from these bags. Warranty & service Equipment is covered by a limited warranty period of three years from date of first delivery unless contrary conditions apply under a particular contract of supply. For situations when No Fault Found for repairs, a minimum charge of $A00.00 will apply, whether the equipment is within the warranty period or not. Equipment warranty is limited to faults attributable to defects in original design or manufacture. Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier. Equipment return: Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment. If possible, confirm this by substitution. Before returning equipment contact should be made with IRT or your local agent to determine whether the equipment can be serviced in the field or should be returned for repair. The equipment should be properly packed for return observing antistatic procedures. The following information should accompany the unit to be returned:. A fault report should be included indicating the nature of the fault. The operating conditions under which the fault initially occurred.. Any additional information which may be of assistance in fault location and remedy. 4. A contact name and telephone and fax numbers. 5. Details of payment method for items not covered by warranty. 6. Full return address. 7. For situations when No Fault Found for repairs, a minimum charge of $A00.00 will apply, whether the equipment is within the warranty period or not. Please note that all freight charges are the responsibility of the customer. The equipment should be returned to the agent who originally supplied the equipment or, where this is not possible, to IRT direct as follows. Equipment Service IRT Electronics Pty Ltd 6 Hotham Parade ARTARMON N.S.W. 064 AUSTRALIA Phone: Fax: service@irtelectronics.com 007-dva.ib.doc Page 8 of 9 6/0/00

9 Drawing Index Note: Components marked n/c on the diagrams are optional and are not included on standard production units. They are shown to assist with interpretation of additional or optional functions, which may be included or are necessary for factory set-up procedures. Drawing # Sheet # Description DVA-007 Circuit Schematic ZVA-006RL Bypass Relay Rear Assembly (optional). 007-dva.ib.doc Page 9 of 9 6/0/00

10 P SK9 L9R R9R SK8 L8R COPYRIGHT DVA-007 SDI/ASI Reclocking Distribution Amplifier Title SIZE A DO NOT COPY NOR DISCLOSE TO ANY THIRD PARTY WITHOUT WRITTEN CONSENT SCALE Sheet Drawing No N.T.S. of IRT Electronics Pty. Ltd. ARTARMON NSW AUSTRALIA 064 DRAWN K.N. CHECKED ENG. APP. Revision: Date: 6-Feb ECR ECR4 Input, Reclocking and Output Circuit Output 8 R8R GND Output 7 SK7 Output 6 L7R Monitor O/P Output 5 Output 4 Signal Detect Output R7R Output Input Output 80456s.sch Power Supply Circuit AC AC AC CT GND AC AC 4 SK s.sch L6R LK R6R 'DC' R40 680R LD HLMP-50 SK5 'grn' L5R n.c. R5R n.o. A B A B A B 4A 4B SK4 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B L4R P J optional power in (used when fitted to FRU-00 frame) DIN64RA PCB R8 0K C6 00nF 'SIGNAL' MON. O/P SK 'grn' LD HLMP-50 R9 680R ALARM CIRCUIT CONTACT CLOSURE (OR BREAK) TO GROUND ON ALARM, AS SET BY LK Q BSS C7 4u7 RLB RLA 5 V06 0 D BAS6 C46 0nF LR-L9R = 5nH RR-R9R = 68R JP RXE00 POLYFUSE 8 C45 0nF J DIN64 A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B R4R SK LR RR SK LR RR JP 0R0 P JP4 0R JP5 0R0 J JP6 0R0 LR SK INPUT RR SK ECR44

11 LR-L7R = 8nH SIZE Title A COPYRIGHT ZVA-006RL SDI/ASI D.A. Rear Panel SCALE Sheet Drawing No N.T.S. of IRT Electronics Pty. Ltd. ARTARMON NSW AUSTRALIA 064 DO NOT COPY NOR DISCLOSE TO ANY THIRD PARTY WITHOUT WRITTEN CONSENT ECR45 PCB J DIN64 A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B L7R DRAWN K.N. CHECKED ENG. APP. Revision: Date: 4-Nov-00 R7R SK7 L6R R6R SK6 L5R R5R SK5 75R L4R R4R SK4 75R LR RR-R7R = 0R RR LR J optional power in (used when fitted to FRU-00 frame) LR 8nH SK INPUT SK RR JP 0R0 JP 0R0 JP4 0R0 JP5 0R0 SK0 J RLR G5Y-54P RR 56R SK P MTMM-0 R8R R9R P MTMM-05 DR BAS6

I R T Electronics Pty Ltd A.B.N. 5 000 8 575 6 Hotham Parade, ARTARMON N.S.W. 064 AUSTRALIA National: Phone: (0) 949 744 Fax: (0) 949 749 International: +6 949 744 +6 949 749 Email: sales@irtelectronics.com

More information

AMS x1 Video + Audio Passive Switcher. User Manual. I.R.T. Communications Pty Ltd Page 1 of 10 Revision 03

AMS x1 Video + Audio Passive Switcher. User Manual. I.R.T. Communications Pty Ltd   Page 1 of 10 Revision 03 10x1 Video + Audio Passive Switcher User Manual Page 1 of 10 Revision 03 10x1 VIDEO + AUDIO PASSIVE SWITCHER Revision History: Revision Date By Change Description Applicable to: 00 17/09/2001 SH Original

More information

User Manual DDA-4320 & ZDA-4320RH. ASI / SDI / STM-1 Path Protection & Distribution Amplifier. Page 1 of 17 Revision 08

User Manual DDA-4320 & ZDA-4320RH. ASI / SDI / STM-1 Path Protection & Distribution Amplifier. Page 1 of 17 Revision 08 ASI / SDI / STM-1 Path Protection & Distribution Amplifier User Manual Page 1 of 17 Revision 08 ASI / SDI / STM-1 PATH PROTECTION & DISTRIBUTION AMPLIFIER Revision History: Revision Date By Change Description

More information

I R T Electronics Pty Ltd A.B.N. 35 000 83 575 6 Hotham Parade, ARTARMON N.S.W. 064 AUSTRALIA National: Phone: (0) 9439 3744 Fax: (0) 9439 7439 International: +6 9439 3744 +6 9439 7439 Email: sales@irtelectronics.com

More information

I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 9439 7439 Email:

More information

FRU RU Frame with built in AC PSU. User Manual. I.R.T. Communications Pty Ltd Revision 03

FRU RU Frame with built in AC PSU. User Manual. I.R.T. Communications Pty Ltd   Revision 03 1RU Frame with built in AC PSU User Manual Revision 03 1RU FRAME WITH BUILT IN AC PSU Revision History: Revision Date By Change Description Applicable to: 00 23/04/2008 AL Original Issue. S/N: 0801001

More information

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM Document No. 101052 Rev. 01 PAGE 2 INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF

More information

UTAH-100/XHDA SERIES

UTAH-100/XHDA SERIES Utah Sandar AS User Manual & Installation Guide UTAH-100/XHDA SERIES SD & HD3G Digital Distribution 1:4 & 1:8 CONTENTS CONTENTS... 2 INTRODUCTION... 3 WARRANTY... 3 DOCUMENT REVISION HISTORY... 3 SAFETY

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

AMU1-CHD+MK2 AUDIO MONITORING UNIT

AMU1-CHD+MK2 AUDIO MONITORING UNIT AMU1-CHD+MK2 AUDIO MONITORING UNIT Handbook TSL Products Units 1-2, First Avenue, Globe Park, Marlow, Bucks, SL7 1YA Telephone +44 (0)1628 564610 This Page is Blank SAFETY Installation. Unless otherwise

More information

ViaLite RF Splitter / Combiner

ViaLite RF Splitter / Combiner RF Splitter / Combiner User Manual LRD-HB-3 CR2721 20/11/09 Pulse Power & Measurement Ltd, 65 Shrivenham Hundred Business Park, Watchfield, Swindon, Wiltshire SN68TY, UK Tel +44 (0)1793 784389 Fax +44

More information

SPECTRA ENGINEERING PTY LTD

SPECTRA ENGINEERING PTY LTD Serial Splitter Unit SPECTRA ENGINEERING PTY LTD MXSSU MXSSU Spectra Engineering Pty Ltd ABN 0 Trade Road Malaga Western Australia 00 Tel: +-- Fax: +-- Email: info@spectraeng.com.au Web: www.spectraeng.com.au

More information

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE Document No. 10102303 PAGE 1 INDEX 1 1 TECHNICAL SUMMARY... 3 1.1 BRIEF DESCRIPTION...3 1.1.1 OVERVIEW...

More information

8 Channel Contact Closure DIN Fiber Link System

8 Channel Contact Closure DIN Fiber Link System USER GUIDE The leader in rugged fiber optic technology. U-028 2017B-0420 8 Channel Contact Closure DIN Fiber Link System SYSTEM INSTALLATI INFORMATI Description The RLH 8 Channel Contact Closure DIN Fiber

More information

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.

More information

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02 1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE Document No. 10100902 PAGE 1 INDEX 1 1 TECHNICAL SUMMARY... 3 1.1 BRIEF DESCRIPTION...3 1.1.1 OVERVIEW...

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide ADS 3120 Plus 120W ac/dc Mixer Amplifier PLEASE NOTE: THIS MANUAL AND THE NOTES CONTAINED HEREIN ARE COPYRIGHT AND MAY NOT BE REPRODUCED EITHER WHOLLY OR IN PART, IN ANY

More information

Operating Manual AMIS60, 60w Mixer Amplifier & AMIS120, 120w Mixer Amplifier

Operating Manual AMIS60, 60w Mixer Amplifier & AMIS120, 120w Mixer Amplifier Clever Features, Contactor Friendly Operating Manual AMIS60, 60w Mixer Amplifier & AMIS120, 120w Mixer Amplifier Product Description The AMIS60 and AMIS120 mixer amplifiers are designed for commercial

More information

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE OPERATOR MANUAL OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER WITH PoE SOURCE INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4

More information

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5 Artistic Licence Rail-Switch II User Guide Version 5-5 Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be

More information

OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM

OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM INDEX 1 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

4 Channel Contact Closure DIN Fiber Link System

4 Channel Contact Closure DIN Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-027 2017A-0420 4 Channel Contact Closure DIN Fiber Link System SYSTEM INSTALLATI INFORMATI Description The 4 Channel Contact

More information

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR

More information

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-10M Protection Switch January 2009 Rev O ALARMS MENU OUTPUT = CH1 AUTO POWER 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 CH2 REMOTE EXECUTE Data, drawings, and other

More information

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General

More information

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-022 2017A-0330 4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System SYSTEM INSTALLATION INFORMATION Description The 4 Channel

More information

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL GENERAL DETAIL The AVC2 will control a stereo channel to a preset maximum output level allowing the maximum sound level of a system to be controlled. The AVC2

More information

OPERATOR MANUAL OSD420 SERIES VIDEO, AUDIO AND DATA FIBER OPTIC TRANSMISSION SYSTEM

OPERATOR MANUAL OSD420 SERIES VIDEO, AUDIO AND DATA FIBER OPTIC TRANSMISSION SYSTEM OPERATOR MANUAL OSD420 SERIES VIDEO, AUDIO AND DATA FIBER OPTIC TRANSMISSION SYSTEM INDEX 1 1 TECHNICAL SUMMARY... 2 1.1 BRIEF DESCRIPTION...2 1.1.1 APPLICATIONS... 2 1.1.2 FEATURES AND BENEFITS... 2

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

National Semiconductor EVK User Manual

National Semiconductor EVK User Manual SD356EVK Evaluation Kit Board for LMH0356 SDI Reclocker User Manual National Semiconductor EVK User Manual Introduction The LMH0356 Serial Digital Interface (SDI) reclocker is designed to recover a clean

More information

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM Page 2 of 16 INDEX 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...

More information

General Operating, Maintenance and Installation Manual

General Operating, Maintenance and Installation Manual General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

Chassis Power Supplies

Chassis Power Supplies PDC24 / PAC Chassis Power Supplies (PDC24 / PAC) Issue 3 October 2005 INTRODUCTION PURPOSE Two Power Supply Units (PSUs) provide a dual-redundant source of 5.4Vand 12Vdc onto the backplane for the modules

More information

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT ISSUE 6 VIP-804 QUAD ENHANCED NETWORK AUDIO PORT INTRODUCTION The VIP-804 Quad Enhanced Network Audio Port enables voice access to four zones of one-way paging over an IP network, allowing page zones to

More information

MADI-PC MADI RECORDING SYSTEM

MADI-PC MADI RECORDING SYSTEM MADI-PC MADI RECORDING SYSTEM USER MANUAL V1.0 1 P a g e Table of Contents INTRODUCTION... 3 IMPORTANT SAFETLY PRECAUTIONS... 4 General Safety... 4 Caution... 4 Power Safety... 5 Installation Notes...

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

6 Port HD/SD-SDI Splitter with Reclocking

6 Port HD/SD-SDI Splitter with Reclocking 6 Port HD/SD-SDI Splitter with Reclocking User s Guide Models SPLIT-HDSDI-6-RS 2008 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview Inc. ( Avenview

More information

TH2683 Insulation Resistance Meter. User s Mannual

TH2683 Insulation Resistance Meter. User s Mannual TH2683 Insulation Resistance Meter User s Mannual 1 CONTENTS Chapter 1 Genernal Information... 3 1.1 Feature Overview... 3 1.2 Operating Environment... 3 1.3 Dimensions and Weight... 3 1.4 Unpacking Inspection...

More information

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-7B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

LCI User Manual mantracourt.com

LCI User Manual mantracourt.com LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence

More information

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1584-25 Splitter December 2009 Rev B MITOR 1 MITOR 2 A B MODEL 1584 DIVIDER CROSS TECHNOLOGIES C. Data, drawings, and other material contained herein are proprietary to Cross Technologies,

More information

1073N. Channel Amplifier. User Manual Issue 1.3

1073N. Channel Amplifier. User Manual Issue 1.3 1073N Channel Amplifier User Manual 527-404 Health & Safety Notice For your own safety and for the protection of others, please observe the following safety precautions: Read these instructions. Keep these

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

MODEL 805 USER MANUAL

MODEL 805 USER MANUAL MODEL 805 USER MANUAL All Rights Reserved Page 1 of 12 UNPACKING & INSPECTION Save all packing materials they are required for returns and warranty service. Inspect the 805 and packing materials for any

More information

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual PMDX-108-Output 8-Channel Isolated Output Board for PC parallel port pins 2-9 User s Manual Date: 25 February 2010 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton,

More information

Advanced Visual Solutions Ltd

Advanced Visual Solutions Ltd Advanced Visual Solutions Ltd Unit 2, Eastman Way Hemel Hempstead, Hertfordshire HP2 7DU Telephone : ( 01442 ) 252280 Fax : ( 01442 ) 244578 Email : visionservices@btclick.com : Website : www.avsl.com

More information

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Contents. HP E1586A Rack Mount Terminal Panel User s Manual Contents HP E1586A Rack Mount Terminal Panel User s Manual Description... 5 Connecting to VXIbus Instruments... 5 Interconnect Cables... 5 Terminal Block Connections... 6 Using the Terminal Panel for Reference

More information

Intrinsically safe batch controller Batching Master 110i

Intrinsically safe batch controller Batching Master 110i Intrinsically safe batch controller Batching Master 110i Installation Guide BVS 04 AT E 172 Revision 12.2 IBS BatchControl GmbH Im Sträßchen 2-4 Tel.: ++49 2441 9199 801 53925 Kall Fax.: ++49 2441 9199

More information

Masibus Automation And Instrumentation Pvt. Ltd.

Masibus Automation And Instrumentation Pvt. Ltd. User Manual 16 CHANNEL DIGITAL INPUT MODULE MASDI DI16 16D Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector25, Gandhinagar382044, Gujarat, India Phone No : 91 79 23287275

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS VERSION 1.7 npi 2015 npi electronic GmbH, Bauhofring 16, D-71732 Tamm, Germany Phone +49 (0)7141-9730230;

More information

SoundwebTM. Installation Guide

SoundwebTM. Installation Guide 105 SoundwebTM Soundweb TM 9000 Installation Guide Soundweb TM Regulatory Information An example of this equipment has been tested and found to comply with the following European and international Standards

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

16-Channel Digital Input Termination Card 24Vdc

16-Channel Digital Input Termination Card 24Vdc TDI16BIA 16-Channel Digital Input Termination Card 24Vdc (TDI16BIA) Issue 3 October 2005 INTRODUCTION PURPOSE The TDI16BIA16-channel digital input termination card acts as an interface between the digital

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

Blue LED Pulsed Light Source LS-475. Installation and Operation Manual Document Number

Blue LED Pulsed Light Source LS-475. Installation and Operation Manual Document Number Blue LED Pulsed Light Source LS-475 Installation and Operation Manual Document Number 000-10000-100-02-1209 Offices: Ocean Optics, Inc. 830 Douglas Ave., Dunedin, FL, USA 34698 Phone 727.733.2447 Fax 727.733.3962

More information

ViaLite Digital GPS Fibre Optic Link

ViaLite Digital GPS Fibre Optic Link ViaLite Digital GPS Fibre Optic Link User Manual LSx-HB-8 CR2874 14/04/11 Pulse Power & Measurement Ltd, 65 Shrivenham Hundred Business Park, Watchfield, Swindon, Wiltshire SN68TY, UK Tel +44 (0)1793 784389

More information

PS8 - II. Professional Power Sequencer. User s Manual

PS8 - II. Professional Power Sequencer. User s Manual PS8 - II Professional Power Sequencer User s Manual IMPORTANT SAFETY INSTRUCTIONS READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure.

More information

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-6B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

ABB Drives. User s Manual I/O Module Adapter AIMA-01

ABB Drives. User s Manual I/O Module Adapter AIMA-01 ABB Drives User s Manual I/O Module Adapter AIMA-01 I/O Module Adapter AIMA-01 User s Manual 3AFE 64661442 REV A EN EFFECTIVE: 1.12.2003 2003 ABB Oy. All Rights Reserved. 5 Safety instructions Overview

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000-006, Rev. A, May 17, 2013 All technical data and specifications in this publication are subject to change without prior

More information

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: + 31

More information

High Voltage Power Supply (MMPS) - Troubleshooting Guide

High Voltage Power Supply (MMPS) - Troubleshooting Guide High Voltage Power Supply (MMPS) - Troubleshooting Guide LAST UPDATED: 09/19/2018 High Voltage Power Supply (MMPS) - Troubleshooting Guide Overview The High Voltage Power Supply (MMPS - MINIMILL Power

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47 OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 2012 SAFETY NOTICE Universal Interface Device 47 (UID46) connects

More information

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review... TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...

More information

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS OPERATING INSTRUCTIONS BASIC PA AMPLIFIER A-1031 A-1061 A-1121 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy

More information

16-Channel Digital Input Termination Card 24Vdc

16-Channel Digital Input Termination Card 24Vdc TDI16AIA 16-Channel Digital Input Termination Card 24Vdc (TDI16AIA) Issue 3 October 2005 INTRODUCTION PURPOSE The TDI16AIA 16-channel digital input termination card acts as an interface between the digital

More information

Instruction Manual. BMS CARD Model: DP-OPT-CARD-OP. Supplied by: - Retrofit to (or supplied with) DIGICHEM Plus + Controllers

Instruction Manual. BMS CARD Model: DP-OPT-CARD-OP. Supplied by: - Retrofit to (or supplied with) DIGICHEM Plus + Controllers Instruction Manual BMS CARD Model: DP-OPT-CARD-OP - Retrofit to (or supplied with) DIGICHEM Plus + Controllers - 4-20mA Outputs - NPN Open Collector Status Outputs for Power Failure, Flow, Alarm & Individual

More information

The TSL Tally and UMD Configuring Program. Power Supply PSU-22 this section is intended to be read in conjunction with the Introduction

The TSL Tally and UMD Configuring Program. Power Supply PSU-22 this section is intended to be read in conjunction with the Introduction The TSL Tally and UMD Configuring Program Power Supply PSU-22 this section is intended to be read in conjunction with the Introduction Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01 ABB Drives User s Manual Analogue I/O Extension Module RAIO-01 Analogue I/O Extension Module RAIO-01 User s Manual 3AFE 64484567 REV A EN EFFECTIVE: 1.2.2002 2002 ABB Oy. All Rights Reserved. Safety

More information

S-Band Redundant LNA Systems

S-Band Redundant LNA Systems S-Band Redundant LNA Systems LRS-1000 Series Introduction Redundant LNA systems minimize system downtime due to LNA failure by providing a spare LNA and an automatic means of switching to the spare upon

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

CTI CALL INFORMATION INTERFACE

CTI CALL INFORMATION INTERFACE CTI CALL INFORMATION INTERFACE MODEL CN-4750 SERIAL/ITEM 533/nnn OPERATOR MANUAL Issue 3, FEB, 2002 AUTHOR: PETER ZEUG PATENTS PENDING DESIGNED AND MANUFACTURED IN AUSTRALIA DESIGN TWO THOUSAND PTY LTD

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER / OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER PAGE 2 OF 17 INDEX 1 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

EOS-6000 Series Optical A/B Switch User Manual DC Version

EOS-6000 Series Optical A/B Switch User Manual DC Version EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2

More information

Instruction Sheet Board Style Low Water Cutoff

Instruction Sheet Board Style Low Water Cutoff Instruction Sheet Board Style Low Water Cutoff 102-305 SUPERSEDES: REVISION E DATED December 12, 2007 #5401173-REV F PLANT ID 001-3902 US Patents 6,904,800, 7,243,540, and 7,317,993 Other Patents Pending

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide ADS 5240 240W ac/dc Mixer Amplifier PLEASE NOTE: THIS MANUAL AND THE NOTES CONTAINED HEREIN ARE COPYRIGHT AND MAY NOT BE REPRODUCED EITHER WHOLLY OR IN PART, IN ANY WAY WHATSOEVER,

More information

ACM w Mixer Amplifier. Operating Manual

ACM w Mixer Amplifier. Operating Manual ACM250 250w Mixer Amplifier Operating Manual ACM250, 250 Watt Mixer Amplifier Product Description The ACM250 mixer amplifier is designed for commercial installations. It operates on 230/240 VAC, 50Hz (or

More information

MASELEC MTC-6 master transfer and monitor system

MASELEC MTC-6 master transfer and monitor system MASELEC MTC-6 master transfer and monitor system http://www.maselec.com/ Mases Electronics Ltd. Bishopswood, Cannon Hill Close, Bray, Berks SL6 2DH, England. Tel/Fax: +44 (0) 1628-770 104. E-mail: leif@maselec.com

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47 OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 202 SAFETY NOTICE Universal Interface Device 47 (UID47) connects two

More information

250 Mbps Transceiver in LC FB2M5LVR

250 Mbps Transceiver in LC FB2M5LVR 250 Mbps Transceiver in LC FB2M5LVR DATA SHEET 650 nm 250 Mbps Fiber Optic Transceiver with LC Termination LVDS I/O IEC 61754-20 Compliant FEATURES LC click lock mechanism for confident connections Compatible

More information

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

CEM M-RS485 INSTRUCTION MANUAL (M014B A) Communications interface CEM M-RS485 INSTRUCTION MANUAL (M014B01-03-14A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could

More information

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION

More information

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-5B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

Model DPDT Switch Module

Model DPDT Switch Module Model 3000 4356 20 DPDT Switch Module 90401290 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part

More information