TM-Series. Technical Description TM-301 chassis Rev Q,
|
|
- Annice Randall
- 5 years ago
- Views:
Transcription
1 TM-Series Technical Description TM-301 chassis Rev Q,
2 Transmode TD-TM301 Q 2 (26) 1 GENERAL The specifications and information within this manual are subject to change without further notice. All statements, information and recommendations are believed to be accurate but are presented without warranty of any kind. Users must take full responsibility for their application of any products. In no event shall be liable for any indirect, special, consequential or incidental damages, including, without limitation, lost profits or loss or damage to data arising from the use or inability to use this manual, even if Transmode or its suppliers have been advised of the possibility of such damages. 1.1 In commercial confidence The manual is provided in commercial confidence and shall be treated as such. 1.2 Document Revision History Revision Date Description of changes A First released version B Added information on max power consumption in card cage Added mechanical drawings, noise level values C Restriction: A CU is always required for configurations with 3 Traffic Units. D Transition to new Transmode format. No content change. E Clarifications and minor updates of figures F Updated with ordering numbers for different slot configurations G Added information on labels Added information on air filter H Cosmetically updates I Removal of configurations without CU J Updated with new article codes. Text changes to reflect introduction of CU-SFP K Change of logotype L Addition of 23 mounting. Enhancements. M Addition of chapter Addition of chapter Addition of Appendix with configuration examples N Updated tables in section to reflect release 13.0 content O Addition of max inrush current in Table 6 P Introduction of new AC/DC module and configuration without any half-sized slots Q MDU-8 units incorrectly stated not to be supported. Corrected Table
3 Transmode TD-TM301 Q 3 (26) Table of content 1 General In commercial confidence Document Revision History Functional Description Introduction Basic configurations TM-301 chassis Fan units Air filter Primary power alternatives External interfaces Card Cage Plug-in unit data & chassis compatibility Chassis Identity Labels Product identifiers Technical data Revision data Ordering data Spare parts Mechanical drawings APPENDIX TM-301 Configurations Line amplifier configuration G Terminal node Large Terminal node
4 Transmode TD-TM301 Q 4 (26) 2 FUNCTIONAL DESCRIPTION 2.1 Introduction The TM-301 chassis is the medium-sized chassis alternative in the TM-Series. The TM-301 is perfect for smaller collector nodes or to house an intermediate amplifier site. A Control Unit (CU) is always placed in the first slot. The CU gives an aggregated management view of the chassis. In the standard configuration, two full-sized units can be mounted together with up to four half-sized units. The TM-301 is provided in AC or DC primary powering options and different mounting options. For details on installation procedure, see TM-301 Installation Guide within the Installation & Commissioning volume of the TM-Series System manual. 2.2 Basic configurations A Basic TM-301 NE Equipment include Control Unit (CU-SFP) Dummy panels Dual Fan units Dual DC/DC converters with DC cables Ethernet cable, DSUB/RJ45 converter, ESD wrist wrap The mounting option adds on Mounting brackets 19, ETSI or 23 with screws and nuts The AC power option adds on Separate AC/DC converters For configurations where OSC channels are needed, the required amount of SFP s must be added separately. See Dimensioning Guidelines within System Manual for more details. Figure 1: Basic Equipment TM-301 with CU-SFP 2009
5 Transmode TD-TM301 Q 5 (26) 2.3 TM-301 chassis The TM-301 chassis can be divided into four parts: Fan area Card cage Power and external interfaces Fiber management area Figure 2: The main parts of a TM-301 NE Platform The Fan and Power and external interface modules are screwed to the mechanics but still easy to extract via handles. Different mounting brackets are used when mounting the TM-301 into an ETSI, 19 or a 23 building practice. Fiber slack can be handled via the fiber management area. A separate fiber management shelf is recommended for configurations with plug-in units having multiple client ports. 2009
6 Transmode TD-TM301 Q 6 (26) Fan units On the left a fan unit module is placed. It can easily be extracted and replaced by pulling the module outwards using the handle. Figure 3: Cooling of TM-301 The fan module contains two fan units. If one fan unit fails the red LED on the cover panel will ignite and an alarm will be generated to the Control Unit. The other FAN unit has the capacity to cool the system alone. A hot-swap of the failed unit can be done. On the far right side a mechanical air filter is placed. It can be extracted for replacement. The airflow is shown in Figure Air filter An air filter is placed on the far right hand side of the card cage. This filter should be extracted and cleaned every second year under normal conditions. See System Manual Operation & Maintenance, Spare Part & Maintenance Guide for more details. 2009
7 Transmode TD-TM301 Q 7 (26) Primary power alternatives On the right side, two slots are available for primary power configurations. AC-power An AC powered configuration is shown in Figure 4. The AC/DC conversion is done in an external unit and connected to one of the DC inlet modules. Two DC input modules are provided to allow for A & B power configurations. The AC voltage accepted is either 115 or 230V. Figure 4: AC power configuration A green LED indicator (PWR) is placed on the front of the module to indicate a functioning unit. Upon failure, the LED will be turned off and an alarm will be generated to the management system. A hot-swap replacement of the failed module can be done. The red LED (POL ERR) indicates polarity error, i.e. the 48 voltage has been wrongly connected. This is only a visual indication and will not generate any alarm to the management system. The AC/DC unit has a green LED indicator to indicate correct function. 2009
8 Transmode TD-TM301 Q 8 (26) DC-power External -48V DC power is here connected directly to the DC power inlet modules. The two modules are used to enable A & B power configurations. Both 2-wire and 3-wire configurations are possible. Figure 5: DC power configuration A green LED indicator (PWR) is placed on the front of the module to indicate a functioning unit. Upon failure, the LED will be turned off and an alarm will be generated to the management system. A hot-swap replacement of the failed module can be done. The red LED (POL ERR) indicates polarity error, i.e. the 48 voltage has been wrongly connected. This is only a visual indication and will not generate any alarm to the management system. Note! The same product (TM-301-DDC/19, /ETSI with R-state R1B) is used for both AC and DC powering. In the AC configuration external AC/DC units are added and connected to the DC inlet connectors. In the DC-configuration, the DC voltage is connected directly. The previous R-state R1A had a special DC-inlet module. Fuse 3,15A 2009
9 Transmode TD-TM301 Q 9 (26) External interfaces To the far right a LAN module is situated for electrical connections. Figure 6: LAN module Three RJ-45 connector types are available for the following applications: DCN 1 Management interface to the Network Element. A LAN-connection via Ethernet interface (10Mb/s or 100Mb/s) that can be connected directly to a Transmode Network Manager (TNM) platform or via a DCN network. ICN 3 & ICN 4 Internal Communication Network, used when connecting multiple TM- 301 platforms to create a larger NE. See Installation & Commissioning manual for further details. The electrical Ethernet interfaces can be connected to its interfacing equipment with an Ethernet cable and is suitable for connection to intra-building wiring only. The maximum allowed physical length of the cable is 100 m, provided that a Cat 5e class shielded cable is used and the shield is grounded at both ends. Unshielded cable usage is not warranted by Transmode and such usage is discouraged. 2009
10 Transmode TD-TM301 Q 10 (26) Card Cage Figure 7: TM-301 card cage area The card cage has one dedicated slot (slot 1) for a Control Unit (CU). The two following slots (2 & 3) are for full-height Traffic Units. Slots 4 to 7 are in the standard configuration used for four half-sized units, i.e. typically passive units. The wall between slots 4-5 and 6-7 can be reduced to provide one or two additional fullsized slots. This is reconfiguration that has to be done in production and consequently these configurations are ordered via separate ordering numbers (see chapter 4.2). Figure 8: Slot usage in standard configuration TM301xxyy/2 In the standard configuration TM301xxyy/2 the TM-301 can be equipped with up to two active units (Transponders, Muxponders, Optical Amplifiers) and four half-height units. 2009
11 Transmode TD-TM301 Q 11 (26) Figure 9: Slot usage in special configuration TM301xxyy/1 In the special configuration TM301xxyy/1 the TM-301 can be equipped with up to three active units (Transponders, Muxponders, Optical Amplifiers) and two half-height units. Figure 10: Slot usage in special configuration TM301xxyy/0 In the special configuration TM301xxyy/0 the TM-301 can be equipped with up to three active units (Transponders, Muxponders, Optical Amplifiers) and one passive full-height unit. Note! In the TM301xxyy/0 configuration the bottom slot 5 must only be equipped with passive units since the air flow from the fan unit is not sufficient for an active unit. In the TM301xxyy/0 configuration the slot 5 can be used for e.g. a MDU8EE unit. Note: In the special configurations TM301xxyy/1 and TM301xxyy/0 where three Traffic Units can be inserted, there are power dissipation restrictions that may prohibit some combinations of high-power units. Always verify that the power consumption is within the limits. In DC-powering the max power dissipation within the card cage is 120W. In AC-powering the max power dissipation is dependent on used AC/DC converter: - PS1A-120/DS3 restricts the power within the card cage to 101W. - PS1A-180/DS3 provides same power within the card cage as for DC, i.e. 120W. PS1A-180/DS3 was introduced in Dec 2009 and shipment of TM-301 in AC configuration is done with PS1A-180/DS3 from that point in time. A CU-SFP with OSC transceivers will consume 20W of the above values. A CU-SFP without OSC transceivers will consume 18W of the above values. 2009
12 Transmode TD-TM301 Q 12 (26) Plug-in unit data & chassis compatibility The below tables lists all plug-in units available at release For each plug-in unit a Type parameters is defined; Type has four parameters; A = Active unit, i.e. must be inserted in an active slot P = Passive unit, i.e. must be inserted in an active slot FH = Full-height unit, i.e. occupies a full-height slot HH = Half-height unit, i.e. occupies a half-height slot Every unit is a combination of Active/Passive and Full-height/Half-height. As an example: The TPQMR has the type A/FH meaning that the unit shall be inserted in an active, full-height slot. Table 1: Plug-in unit data and chassis compatibility (Release 14.0 content) Category Item Name Item ID Type Slot TM- TM- TM- TMwidth MultiRate 2500 DWDM Transponder V2 TPMR25-V2/xxxxx A/FH 1 Y Y Y Y Transponders Quad MultiRate xwdm Transponder TPQMR A/FH 1 Y Y Y Y Muxponders Double DGbE xwdm, Basic Unit TPDDGBE A/FH 1 Y Y Y 2.5G line rate 10-port GFP xwdm Muxponder GXP10/2500-SFP A/FH 1 Y Y Y Y 8-port SDH xwdm Muxponder MXP8 A/FH 1 Y Y Y MultiService Muxponder MS-MXP A/FH 1 Y Y Y Y 4G line rate Quad MultiService Transponder TPQMS A/FH 1 Y Y Y Y Double 10Gb/s Lite Basic Unit TPD10G-L-BU A/FH 1 Y Y Y Y 10Gb/s Transponder, Client-XFP, BU TP10GCLX/xxxxx A/FH 1 Y Y Y Y 10Gb/s C-band Tunable Transp TP10GCLX/TC A/FH 1 Y Y Y Y 10Gb/s C-band Tunable Ext Reach TP10G/TC-ER A/FH 1 Y Y Y 10G line rate Layer-2 10G C-band Tunable OTN Transponder TP10GOTN/TC A/FH 1 Y Y Y Y 9xGbE/10Gb Muxponder, BU GBE9-MXP10G A/FH 1 Y Y Y Y 9xGbE/10G FEC Muxponder GBE9/MXP10GFEC A/FH 1 Y Y Y Y Double 10Gb/s FEC Basic Unit TPD10GBE-BU A/FH 1 Y Y N Y 4xSTM-16/STM-64 Muxponder 4x2G5-MXP10G A/FH 1 Y Y Y Y MultiService MuxPonder 10G MS-MXP/10G A/FH 1 Y Y Y Y MultiService MXP Tunable 10G ER MS-MXP10G/TC-ER A/FH 1 Y Y N N 6-port GbE Ethernet Demarcation Unit EDU/6PGBE A/FH 1 Y Y Y Y 10xGbE/10GbE Ethernet Muxponder GBE10-EMXP10 A/FH 1 Y Y Y Y 22xGbE/10GbE Ethernet Muxponder GBE22-EMXP10 A/FH 2 Y Y N N 12-port GbE Ethernet Demarcation Unit EDU/12PGBE A/FH 1 Y Y Y Y Type A = Active unit, i.e. must be inserted in an active slot Type P = Passive unit, i.e. must be inserted in an active slot Type FH = Full-height unit, i.e. occupies a full-height slot Type HH = Half-height unit, i.e. occupies a half-height slot 2009
13 Transmode TD-TM301 Q 13 (26) Table 2: Plug-in unit data and chassis compatibility (Release 14.0 content), cont. Category Item Name Item ID Type DWDM Optical Add/drop DWDM Optical Mux/DeMux Misc DWDM Slot width TM ch DWDM Add-Drop Unit, AB-version AD1AB/xxxxx 1ch DWDM Add-Drop Unit, BA-version AD1BA/xxxxx P/HH 1 Y Y Y Y 2ch DWDM Add-Drop Unit, AB-version AD2AB/xxxxx 2ch DWDM Add-Drop Unit, BA-version AD2BA/xxxxx P/HH 1 Y Y Y Y 4ch DWDM Add-Drop Unit, AB-version AD4AB/xxxxx 4ch DWDM Add-Drop Unit, BA-version AD4BA/xxxxx P/HH 1 Y Y Y Y 2ch OA DWDM Add-Drop Unit AB AD2OAAB/xxxxx 2ch OA DWDM Add-Drop Unit BA AD2OABA/xxxxx P/HH 1 Y Y Y Y 1ch/2F A/D DWDM Add-Drop AD1-2F/xxxxx P/HH 1 Y Y Y Y 4ch/2-fiber DWDM Add-Drop AD4-2F/xxxxx P/HH 1 Y Y Y Y 1x4 ROADM 100GHz 1x4ROADM/100G A/FH 2 Y N N N 8ch Mux/DeMux, Extendable MDU8-E P/FH 1 Y Y N N 8ch Mux/DeMux, Terminal MDU8-T P/FH 1 Y Y N N 8ch Even Mux/DeMux, Extendable MDU8-E/EVEN-C P/FH 1 Y Y N N 8ch Even Mux/DeMux, Terminal MDU8-T/EVEN-C P/FH 1 Y Y N N 40ch MDU, even 50GHz DWDM MDU40/50G-EVEN A/FH 3 Y N N N 40ch MDU, odd 50GHz DWDM MDU40/50G-ODD A/FH 3 Y N N N MDU-E 8ch Even 50GHz DWDM MDU8EE P/FH 1 Y Y N N MDU-E 8ch Even 50GHz DWDM MDU8EE P/FH 1 Y Y N N MDU-E 8ch Even 50GHz DWDM MDU8EE P/FH 1 Y Y N N MDU-E 8ch Even 50GHz DWDM MDU8EE P/FH 1 Y Y N N MDU-E 8ch Even 50GHz DWDM MDU8EE P/FH 1 Y Y N N MDU-E 8ch Odd 50GHz DWDM MDU8EO P/FH 1 Y Y N N MDU-E 8ch Odd 50GHz DWDM MDU8EO P/FH 1 Y Y N N MDU-E 8ch Odd 50GHz DWDM MDU8EO P/FH 1 Y Y N N MDU-E 8ch Odd 50GHz DWDM MDU8EO P/FH 1 Y Y N N MDU-E 8ch Odd 50GHz DWDM MDU8EO P/FH 1 Y Y N N Optical Interleaver Unit 100/200GHz OIU-C-100/200 P/HH 1 Y Y Y Y Optical Interleaver Unit 50/100GHz OIU-C-50/100 P/HH 1 Y Y Y Y 8ch Variable Optical Attenuator unit VOA-8CH P/FH 1 Y Y N N 2-port OCM OCM/2p A/FH 1 Y Y N N 8ch Variable Optical Attenuator II VOA-8CH/II A/FH 1 Y Y N N 2ch Variable Optical Attenuator VOA-2CH A/HH 1 Y Y Y Y TM- 301 TM- 101 TM- 102 Table 3: Plug in unit data and chassis compatibility (Release 14.0 content), cont. Category Item Name Item ID Type Slot TM- TM- TM- TMwidth Optical Line Amplifier 17dBm C-band OA17C A/FH 1 Y Y Y Y Dual Optical Line Amplifier 17/17dBm C- band OA2-17/17CC A/FH 1 Y Y Y Y Optical Line Amplifier 20dBm C-band OA20C A/FH 1 Y Y Y Y Optical Dual Optical Line Amplifier 20/20dBm C- Amplifiers OA2-20/20CC A/FH 1 Y Y Y Y band Opt Low Gain Amp C-Band 20dBm OA20C/LG A/FH 1 Y Y Y Y Dual Opt Low Gain Amp C-Band 20dBm OA2-20/20/CC/LG A/FH 1 Y Y Y Y Opt Flat Gain Amp C-Band 10 dbm OA10C/FG A/FH 1 Y Y Y Y Type A = Active unit, i.e. must be inserted in an active slot Type P = Passive unit, i.e. must be inserted in an active slot Type FH = Full-height unit, i.e. occupies a full-height slot Type HH = Half-height unit, i.e. occupies a half-height slot 2009
14 Transmode TD-TM301 Q 14 (26) Table 4:Plug-in unit data and chassis compatibility (Release 14.0 content), cont. Slot TM- TM- TM- TM- Category Item Name Item ID Type width Optical Band Unit OBU1300/1550 P/HH 1 Y Y Y Y Misc passive 2xOptical Coupler Unit OCU2 P/HH 1 Y Y Y Y units 4xOptical Coupler Unit OCU4 P/HH 1 Y Y Y Y Active unit Protection Control Unit PCU/2P A/HH 1 Y N N N Table 5: Plug-in unit data and chassis compatibility (Release 14.0 content), cont. Category Item Name Item ID Type Slot TM- TM- TM- TMwidth ch Add/drop CWDM 1) (singlefiber) ADCWDM/yyyy P/HH 1 Y Y Y Y CWDM 1ch CWDM Add/drop (single-fiber) AD1C/yyyy P/HH 1 Y Y Y Y AD-filters 2x1ch Add/Drop CWDM (singlefiber) AD2X1C/yyyy P/HH 1 Y Y Y Y 1ch/2-fiber CWDM Add-Drop 2) AD1C-2F/yyyy P/HH 1 Y Y Y Y 4ch MDU CWDM, single fiber, TA MDUC4-TA/1470 4ch MDU CWDM, single fiber, TB MDUC4-TB/1470 P/HH 1 Y Y Y Y 4ch MDU CWDM, single fiber, EA MDUC4-EA/1270 P/HH 1 Y Y Y Y 4ch MDU CWDM, single fiber, EB MDUC4-EB/1270 CWDM 8ch CWDM Mux, fiber-pair MU-2F/1470 Optical P/HH 1 Y Y Y Y 8ch CWDM DeMux, fiber-pair DU-2F/1470 Mux/DeMux 4ch CWDM MDU fiber-pair MDU4-E-2F P/HH 1 Y Y Y Y Extendable 4ch CWDM MDU fiber-pair Terminal MDU4-T-2F P/HH 1 Y Y Y Y Type A = Active unit, i.e. must be inserted in an active slot Type P = Passive unit, i.e. must be inserted in an active slot Type FH = Full-height unit, i.e. occupies a full-height slot Type HH = Half-height unit, i.e. occupies a half-height slot 2009
15 Transmode TD-TM301 Q 15 (26) Chassis Identity Each chassis within a NE must have a unique ID number. The chassis identity is set by a DIP-switch that is located on the LAN module (see chapter 2.3.4). By extracting the module, the DIP-switch will be located on the to side of the board. See Figure 11. Figure 11: DIP switch for Chassis ID Up to 16 TM-301 chassis can be connected into one NE. However, normally only one TM- 301 would be used as a NE and stacking multiple TM-301 chassis should be rare. The procedure is described in the Installation & Commissioning Volume of the System Manual. 2009
16 Transmode TD-TM301 Q 16 (26) 3 LABELS The TM-301 chassis is marked with a Product Label and a System Label. Both are placed on the top of the chassis, on the left, front side. The Product label contains: Transmode logotype 2. Product number 3. Product revision 4. Barcode 128 containing: product number space revision 5. Production date: yearwweeknumber 6. Serial number 7. Barcode 128 containing: serial number 8. Barcode 128 containing: product number, revision, production date, serial number 9. Approval markings 2009
17 Transmode TD-TM301 Q 17 (26) The System Label contains: 1. Transmode logotype 2. System type 3. Production date: yearwweeknumber 4. Ratings 5. Laser class, 6. Compliance info, 7. Approval markings 2009
18 Transmode TD-TM301 Q 18 (26) 3.1 Product identifiers Figure 12: Product labels All exchangeable modules on the Basic NE Equipment are labeled. The figure shows labeling of Fan unit LAN module DC-inlet module TM-301 Chassis The label contains the following information: Product number R-state Serial number Bar code with the above information The above information on these specific modules is not accessible via the inventory function in the management system. Inventory data on CU s and Traffic Units are available via the inventory functionality. 2009
19 Transmode TD-TM301 Q 19 (26) 4 TECHNICAL DATA Table 6: Mechanical & electrical data TM-301 Height 3U / 133mm Depth 280mm / 11 Width (excl. mounting brackets) 445mm/17.5 Primary Power DC-inlets. Redundant, Hot-swap Cooling Redundant fans. Hot-swap Mounting ETSI, 19, 23 Fiber management Yes LAN/Mgmt connections RJ45 Primary power range, AC: External AC/DC-converter VAC, 50/60Hz, 2.5A Class I. PS1A-120/DS3 excl connectors. Size AC/DC converter Length: 180mm Width: 95mm Height: 50mm Primary power range DC: 48VDC ( VDC), 5A Class III Max power at AC powering 160 W Max power at DC powering 150 W ~120W in DC powering Max power consumption in card ~101W in AC powering using PS1A-120/DS3 cage (incl CU-SFP) ~120W in AC powering using PS1A-180/DS3 Max Inrush -48VDC 4,0A / 4ms 7,5 kg Weight DC-powering: (mechanics + fan unit + 2x DC TM-301(DC) + LAN module 1,5mm 2 DC cable size (connector limit) Standard 1,0mm 2 Table 7: Capacity TM-301 Number of full-sized slots 1) Up to 3 Number of half-sized slots 2) Up to 4 No of λ in largest possible 8 CWDM or configuration 3) 3 DWDM No of λ in smallest possible configuration 4) 1 CWDM or DWDM wavelength (via 1ch add/drop) 1) Slots for Traffic units (Transponders/MuxPonders) 2) Slots for passive units (Add/drop filters, MDU s) 3) Includes both Traffic units and passive unit within same chassis, i.e. a fully configured NE 4) Using Transponder and optical unit with lowest granularity Note: The TM-301 chassis can mechanically be configured for 2x full-slots + 4x half-slots or 3x full-slots + 2x half-slots 2009
20 Transmode TD-TM301 Q 20 (26) 4.1 Revision data A TM-301 chassis has an order level that includes mechanics, cables, Control Unit etc as listed in chapter 4.2. The table shows revision data on M301/ENC which is the basic card cage mechanics. Changes in this basic mechanics is reflected on the M301/ENC level Table 8: Revision data Product number Rev Introduced Release M301/ENC R1A A2.2 1 st released version R1B A Ordering data Table 9: Configuration alternatives Basic NE-Equipment TM-301 Configuration Ordering code Comments TM-301, DC, 19 Shelf=2 TM301DC19/2 Standard config. TM-301, AC, 19, Shelf=2 TM301AC19/2 Standard config. TM-301, DC, ETSI Shelf=2 TM301DCET/2 Standard config. TM-301, AC, ETSI, Shelf=2 TM301ACET/2 Standard config. TM-301, DC, 23 Shelf=2 TM301DC23/2 Standard config. TM-301, AC, 23, Shelf=2 TM301AC23/2 Standard config. TM-301, DC, 19 Shelf=1 TM301DC19/1 Special config. TM-301, AC, 19, Shelf=1 TM301AC19/1 Special config. TM-301, DC, ETSI Shelf=1 TM301DCET/1 Special config. TM-301, AC, ETSI, Shelf=1 TM301ACET/1 Special config. TM-301, DC, 23 Shelf=1 TM301DC23/1 Special config. TM-301, AC, 23, Shelf=1 TM301AC23/1 Special config. TM-301, DC, 19 Shelf=0 TM301DC19/0 Special config. TM-301, AC, 19, Shelf=0 TM301AC19/0 Special config. TM-301, DC, ETSI Shelf=0 TM301DCET/0 Special config. TM-301, AC, ETSI, Shelf=0 TM301ACET/0 Special config. TM-301, DC, 23 Shelf=0 TM301DC23/0 Special config. TM-301, AC, 23, Shelf=0 TM301AC23/0 Special config. When OSC channels are required, SFP s must be added to the above ordering numbers. See Dimensioning Guidelines within the System Manual for more details. 2009
21 Transmode TD-TM301 Q 21 (26) The above ordering numbers include the following items: TM-301 card cage Control Unit CU-SFP (1 per chassis) DC/DC filter module (2 items per chassis) External AC/DC converter 115/230V 120W (2 per chassis, only for AC configuration) LAN module / RJ 45 card (1 per chassis) Dummy panels, full-sized (2 items) Dummy panels, half-sized (4 items) DC cable, 4m (2 items) Ethernet cable, 2m (1 item) DSUB adapter RJ45/DB9 (1 item) ESD wrist wrap with strap (1 item) Mounting material in rack; nuts, plastic plates, screws (4 sets) Mounting brackets 19 (mounted, 2 per chassis) Mounting brackets ETSI (2 per chassis, only in ETSI version) Mounting brackets 23 (2 per chassis, only in 23 version) Spare parts The TM-301 chassis has the following spare part items: Table 10: Spare parts Item name Item code Comment Fan unit TM-301 M301-FAN One module used per chassis DC power plugin module -48V M301-DC Two modules used per chassis LAN module TM-301 M301-RJ45 One per chassis AC/DC converter (external) PS1A-120/DS3 Two per chassis (replaced by PS1A-180/DS3) M301 ACDC Unit (180W) PS1A-180/DS3 Two per chassis Dummy panel 6HE inkl ovl o EMC-list M3-DU/6HE Full-height slot cover panel Dummy panel 3HE inkl ovl o EMC-list M3-DU/3HE Half-height slot cover panel M301 airfilter M9-M301/AIR One per chassis 2009
22 Transmode TD-TM301 Q 22 (26) 4.3 Mechanical drawings ETSI reference plane 2009
23 Transmode TD-TM301 Q 23 (26) ETSI reference plane 2009
24 Transmode TD-TM301 Q 24 (26) 5 APPENDIX 5.1 TM-301 Configurations Line amplifier configuration Figure 13: Line amplifier NE with OSC channels CU-SFP (with SFP's for OSC channels) 20 W Double OA20 27 W Not used OSC AD-filter OSC AD-filter Not used Not used 47 W total Figure 14: Board placement and power consumption 2009
25 Transmode TD-TM301 Q 25 (26) G Terminal node Figure 15: 4x10G Terminal NE using TPD10G-BU CU-SFP (w/o SFP's for OSC channels) 18 W TPD10GBE-BU 43 W TPD10GBE-BU 43 W 4ch MDU-E 2F Not used Not used Not used 104 W total Figure 16: Board placement and power consumption 2009
26 Transmode TD-TM301 Q 26 (26) Large Terminal node Figure 17: 4x10G Terminal NE using mix of units This configuration uses the special TM-301 configuration enabling three full-sized slots and two half-sized slots. CU-SFP (w/o SFP's for OSC channels) 18 W GBE9/MXP10GFEC 32 W MS-MXP 20 W TPDDGBE 25 W MDUC4-TA/1470 MDUC4-TB/ W total Figure 18: Board placement and power consumption 2009
BRINGING PACKET-OPTICAL NETWORKING TO THE NEXT LEVEL THE TRANSMODE TM-SERIES
BRINGING PACKET-OPTICAL NETWORKING TO THE NEXT LEVEL THE TRANSMODE TM-SERIES THE CHALLENGE OF INCREASING REVENUE, NOT COSTS It is common knowledge that the explosive growth in high bandwidth services for
More informationINNOVATIVE PACKET-OPTICAL NETWORKS FROM ACCESS TO CORE THE TRANSMODE TM-SERIES
INNOVATIVE PACKET-OPTICAL NETWORKS FROM ACCESS TO CORE THE TRANSMODE TM-SERIES AN INNOVATIVE PACKET-OPTICAL METRO NETWORK INDUSTRY-LEADING PERFORMANCE FROM THE CUSTOMER PREMISES TO 100G CORE COST OPTIMIZED
More information5U CWDM Managed Platform SML-5000
CWDM Managed Platform 5U CWDM Managed Platform 5000 The SigmaLinks5000 is a flexible, cost-effective optical transport system, designed to multiplex, de-multiplex and switch high-speed data for storage,
More informationPrisma II Platform. Optoelectronics
Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the
More informationMX Ring. WDM - MUX/DeMUX. MUX/DeMUX. Features Full native mode performance Optical connectors Passive model requires no power.
WDM - MUX/DeMUX MX20-3155 Dual Channel WDM MUX/DeMUX 5 MX20-3155 is a dual channel, passive, protocol transparent, WDM multiplexer/demultiplexer which utilizes two popular WDM lambda channels of 1310nm
More informationTelecom Engineering DWDM/CWDM Lite Manual
Telecom Engineering DWDM/CWDM Lite Manual Features: 4-80 channel DWDMs or 4-16 channel CWDMs Easy to install, requires no configuration Environmentally friendly product, completely passive, no power and
More informationWaveReady Eight-Port Any Service OTN Muxponder WRM-8008T000B
WaveReady Eight-Port Any Service OTN Muxponder WRM-8008T000B www.lumentum.com Data Sheet A flexible WDM transport solution The WRM-8008 is a next-generation OTN muxponder that can transparently aggregate
More informationDATASHEET Scalable & Flexible FMT 9600E Hyperscale DWDM Connect
Data Center & Cloud Computing DATASHEET Scalable & Flexible FMT 9600E Hyperscale DWDM Connect FS.COM Optical Transport for Metro Networks OTN Solutions for Metro/Regional and Long Haul REV.1.1 2018 FMT
More information800xA Networks. NE801 User Manual. Power and productivity for a better worldtm
800xA Networks NE801 User Manual Power and productivity for a better worldtm 800xA Networks NE801 User Manual NOTICE This document contains information about one or more ABB products and may include a
More informationGmux Modular TDMoIP Gateway FEATURES
FEATURES Carrier-class modular TDMoIP gateway, extending high capacity TDM traffic over packet-switched networks (PSNs) Operates opposite other members of RAD s TDMoIP family of products, offering a complete
More informationCONVERGE EXTEND SWITCH AGGREGATE CONNECT CONNECT SWITCH CONVERGE EXTEND AGGREGATE. BTI 7000 Series BTI Product Brochure. the network you need.
SWITCH SWITCH BTI 7000 Series Product Brochure BTI 7000 the network you need. the network you need. the simplicity you want The optical network edge where services connect users must scale rapidly to address
More information- 128 x Gigabit Ethernet connections - 32 x 4G Fibre Channel connections - 8 x 8G Fibre Channel connections - down to 2 Mbps
Active WDM Company Introduction SmartOptics designs and markets all types of fibre optical transmission products. Headquarted in Oslo, Norway, we serve Storage, Data and Telecom Networks worldwide with
More informationQuick Start Guide. C-100 Series Switches
Quick Start Guide C-100 Series Switches C-100 SERIES QUICK START GUIDE Warnings and Cautionary Messages!! Warning: This product does not contain any serviceable user parts. Warning: Installation and removal
More informationData Center & Cloud Computing DATASHEET. FS.COM WDM Transport Networks Data Center & Cloud Computing Infrastruture Solutions
Data Center & Cloud Computing DATASHEET FS.COM WDM Transport Networks Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018 01 Overview About the Features Efficient Usage Supports up 18 to
More informationNew Terminal Amplifier. Whitebox
New Terminal Amplifier Whitebox www.lumentum.com Preliminary Datasheet The Terminal Amplifier Whitebox and its associated Mux/Demux form the endpoint of a transport system link. The Terminal Amplifier
More informationJunos WebApp Secure 5.0 Hardware Guide
Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a
More informationOptical Networking Solutions
Optical Networking Solutions Optelian designs, manufactures and supplies optical networking equipment and solutions for network operators and communication service providers, and provides all services
More informationCisco Prisma II Platform
Cisco Prisma II Platform In optical transmission systems, the network platform forms the foundation of the product family. The Cisco Prisma II platform provides network operators with the unique features
More informationExpanding your network horizons
Datacenter Interconnect Lösungen von 1G bis 100G - Brocade- und Cisco-zertifizierte FibreChannel-Lösungen bis 32G - SAN und IP-Interconnect - Längenrestriktionen bei der Übertragung - 100G ist das neue
More informationINSTALLATION INSTRUCTIONS FOR THE BV10-100/1000
INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000 This document describes the basic steps for installing your BV10-100 or BV10-1000. For detailed information about the BV10-100/1000, see the Ethernet Performance
More informationSeparate Video from Audio and Peripheral Data
VelocityKVM Thinklogical s VelocityKVM systems offer best-in-class fiber optic performance with advanced video, audio and peripheral capabilities. VelocityKVM extenders offer 6.25Gbps bandwidth, to achieve
More informationGeneral. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink
Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T with PoE+, 1x 10/100/1000Base-T or 100/1000Base-X Combo Port, 1x 100/1000Base X SFP Slot General The IP protocol has already left the
More informationCPS3200U Upstream System Telephone Power for Video 48 Vdc Input, ±190 Vdc Output Converter/Limiter System
48 Vdc Input, ±190 Vdc Output Converter/Limiter System The CPS3200 Power System is designed for powering telecom equipment over twisted pairs (RFT-V). The system consists of sixteen converter/limiter cards
More informationMONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1584-25 Splitter December 2009 Rev B MITOR 1 MITOR 2 A B MODEL 1584 DIVIDER CROSS TECHNOLOGIES C. Data, drawings, and other material contained herein are proprietary to Cross Technologies,
More informationQuick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport
PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick
More informationOptical Metro 5040/5080 platforms
Optical Metro 5040/5080 platforms The Optical Metro (OM) 5040 and 5080 are highly-flexible CWDM/ DWDM access units that offer the broadest range of broadband services on a compact 1U platform. They extend
More informationPL INSTALLATION AND CONFIGURATION MANUAL
PL-1000 3.2 INSTALLATION AND CONFIGURATION MANUAL PL-1000 3.2 Installation and Configuration Manual The information and content contained in this document is proprietary and copyrighted to 2012 PacketLight
More informationCooling System. Cooling System Overview. 16-Slot Line Card Chassis Airflow
This chapter describes the components that make up the cooling system of the Cisco CRS Series Carrier Routing System 16-Slot Line Card Chassis. It contains the following sections: 16-Slot Line Card Chassis
More informationCyan Z22 Platform. Edge-Optimized P-OTP. Introduction. Benefits
Cyan Z22 Platform Edge-Optimized P-OTP Introduction The Z22 is Cyan s compact, environmentally hardened packet-optical transport platform (P-OTP) optimized for deployments at the network edge. Cyan Z-Series
More informationDevice Server for the conversion of serial interfaces (RS-232/422/485) to IP.
Manual Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T, 1x SFP Ports MICROSENS General The IP protocol has already left the in-house environment and is going to take all remaining communication
More informationWaveReady WRT-882. Dual 10 G Tunable Transponder
Dual 10 G Tunable Transponder Data Sheet DWDM Reach Extension and Regeneration The WaveReady is a dual bidirectional transponder that converts short-reach 10 G optical signals to long-reach optical interfaces.
More information9. NTP-C11 Remove and Replace an Ethernet Card, page 1-13 As needed, complete this procedure to remove and replace an ONS CL Ethernet card.
CHAPTER 1 This chapter provides procedures for installing the Cisco ONS 15310-CL shelf, cards, and fiber-optic cable. To view a summary of the tools and equipment required for installation, see the Required
More informationERicsson pau 140o family photonic attachment unit
ERicsson pau 140o family photonic attachment unit ERicsson pau The Ericsson Photonic Attachment Unit (PAU) family provides a variety of DWDM networking functions for building the photonic network layer
More informationPHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X
SFP Patching Hub PHB-200M PHB-200 20x 100/1000Base-T to 20x 100/1000Base-X SFP Patching Hub PHB-200M is a 20-channel Managed SFP patching hub that converts copper 100/1000Base-TX to SFPs working at 100Mbps
More informationFRM220 Solution Portfolio
FRM220 Solution Portfolio CTC Union Technologie s FRM220 series chassis solution is a multi-service chassis platform, which provides an economic and reliable solution in high density media converter installations
More informationInstall the Cisco ONS CL
1 CHAPTER This chapter provides procedures for installing the Cisco ONS 15310-CL shelf, cards, and fiber-optic cable. To view a summary of the tools and equipment required for installation, see the Required
More informationSeparate Video from Audio and Peripheral Data
VelocityDVI Thinklogical s VelocityDVI systems offer best-in-class fiber optic performance with advanced video, audio and peripheral capabilities. VelocityDVI extenders offer 6.25Gbps bandwidth, to achieve
More informationMPP1700 User s Manual
2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.
More informationDatasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.
Multi-Service Access Platform OPCOM3500E-12 OPCOM3500E-12 Feature Overview OPCOM3500E MSAP is carrier-class Multi-Service Access Platform, and designed to enable establishment of service-integrated for
More informationInstalling the Cisco MDS 9020 Fabric Switch
CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet
More informationDWDM Cards. 6.1 DWDM Card Overview CHAPTER
CHAPTER 6 This chapter describes Cisco ONS 15454 dense wavelength-division multiplexing (DWDM) card features and functions. For installation and card turn-up procedures, refer to the Cisco ONS 15454 Procedure
More informationTechnical Specifications
This appendix lists specifications for the Cisco ASR 9000 Series Aggregation Services Routers. Cisco ASR 9000 Series Routers Physical s, on page 1 Cisco ASR 9000 Series Routers Environmental Specifications,
More informationSupported Hardware Components
This chapter contains information about the supported hardware components on the Cisco ASR 1001-HX Router and Cisco ASR 1002-HX Router, and contains the following sections: Supported EPAs, page 1 Supported
More informationThe 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.
The 12.5kW power shelf accepts 3-phase input power and provides stable DC output power (1000A at 12.5VDC). The OCP 21-inch power shelf includes a total of 5+5 high-power, hot-swappable PSUs in redundant
More informationProduct Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER
2 7 CHAPTER This chapter describes the Cisco ME 00 series Ethernet switches and contains these sections: Cisco ME 2 Ethernet Switch (ME-C2GS-8S), page - Cisco ME 2 Ethernet Switch (ME-C2GT-8S), page -7
More informationHardware Guide. EPIC Next Generation Firewall. USG6000 Unified Security Gateway V100R001. Give us a call:
EPIC Next Generation Firewall USG6000 Unified Security Gateway V100R001 15333 Avenue of Science, Suite 100 San Diego, CA 92128 Give us a call: 1-855-881-2004 Send us an email: info@edgewave.com For more
More informationS Optical Networks Course Lecture 7: Optical Network Design
S-72.3340 Optical Networks Course Lecture 7: Optical Network Design Edward Mutafungwa Communications Laboratory, Helsinki University of Technology, P. O. Box 2300, FIN-02015 TKK, Finland Tel: +358 9 451
More information1U Device Expansion Unit Configuration Guide
1U Device Expansion Unit Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper
More informationGigaVUE-2404 // Data Sheet
Mgmt Console M/S Rdy 10/100/1000 PORTS (SFP) G1 G2 G3 G4 G1 G2 G3 G4 1 1 2 2 3 3 4 5 4 5 6 6 7 7 8 8 SLOT 2 PORTS 9 16 SLOT 1 PORTS G1-G4 PORTS 1-8 SLOT 3 PORTS 17 24 PS ALARM CUTOFF UP WHEN INSTALLED
More informationCYAN Z-Series. Engineering and Planning Guide
CYAN Z-Series Engineering and Planning Guide Release 5.0 Cyan, Inc. 2013 Copyright and Trademark Copyright 2009 2013 Cyan, Inc. All Rights Reserved. All text, images, graphics, animation, videos, music
More informationBrocade ICX 6610 Switch
6 May 2015 Brocade ICX 6610 Switch Technical Specifications 2015, Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, HyperEdge,
More informationSTATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,
More informationPTC-101 Quick Installation Guide
PTC-101 Quick Installation Guide Moxa Industrial Media Converter Edition 5.1, November 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More informationInstallation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules
Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules
More informationTABLE OF CONTENTS 1. OVERVIEW... 1
TABLE OF CONTENTS 1. OVERVIEW... 1 1.1. SPECIFICATIONS... 1 1.1.1. Electrical... 1 1.1.2. Compliance... 2 1.1.3. Physical... 2 1.2. COOLING... 2 1.2.1. Fan Exhaust... 2 1.3. MOUNTING... 3 1.4. POWER...
More informationInstallation Job Aid for VSP 4450GTX-HT- PWR+
Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationPHB-200M/PHB x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub
SFP Patching Hub PHB-200M/PHB-200 20x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub PHB-200M is a 20-channel Managed SFP patching hub that converts copper 100/1000Base-TX to SFPs working at 100Mbps
More informationOptimux-4T1 Four-Channel T1 Multiplexer
Data Sheet Optimux-4T1 Any Traffic Over Fiber Multiplexes four T1 channels over a fiber optics link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber
More informationInstalling the IPS 4345 and IPS 4360
CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product
More information16-Port Chassis Media Converter System Manual
16-Port Chassis Media Converter System Manual 17732-B 16-Port Media Converter (ST Connectors, Shown) INTRODUCTION This system manual describes the ADC 16-Port Media Converter with SC and ST connectors,
More informationPHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X FE/GbE Media Converter Concentrator
Media Converter Concentrator PHB-200M PHB-200 20x 100/1000Base-T to 20x 100/1000Base-X FE/GbE Media Converter Concentrator PHB-200M is a 20-channel Managed Media Converter that converts copper 100/1000Base-TX
More informationiconverter 2-Module Power Chassis
iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by
More informationBTI7800 Series Hardware Overview and Installation Guide
BTI7800 Series Hardware Overview and Installation Guide Juniper Networks, Inc. 1133 Innovation Way Sunnyvale, CA 94089 USA tel: 408-745-2000 www.juniper.net BT8A78PD0021 03 September 2016 STANDARD product
More informationInstallation Job Aid for Ethernet Routing Switch 5900 Series
Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationiaccess Multi-Service Platform-DM In Band Managed Multi-Service Platform-FRM220 Series
iaccess TM Multi-Service Platform-DM In Band Managed Multi-Service Platform-FRM220 Series Mobile Fronthaul & Backhaul for 4G LTE 10G Ethernet for Data Center Solution Carrier Ethernet (NID & EDD) CWDM
More informationInstallation Job Aid for Avaya Virtual Services Platform 8400
Installation Job Aid for Avaya Virtual Services Platform 8400 Support Release 4.2 NN47227-305 Issue 01.06 June 2015 Go to the Avaya Support website at http://support.avaya.com for the most up-to-date documentation,
More informationAT-9900s Series Switch Expansion Module Installation Guide
AT-9900s Series Switch Expansion Module Installation Guide AT-A60 AT-A61 AT-A62 AT-9900s Series Switch Expansion Module Installation Guide AT-A60 AT-A61 AT-A62 Download the complete document set from www.alliedtelesis.com/support/software
More informationPSA200 User s Manual
2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.
More informationSpecifications Connectors. Chassis backplane consists of passive components. Single or optional redundant power supplies
2U Managed Platform - FRM220 In-band Managed Multi-service Platform FRM220 The FRM220 is a 2U high 19" Rack, 20 slot modular media converter rack. It provides an economic solution in high density fiber
More informationDESCRIPTION. Features
Multi-Ser vice Access Network Features Combined SONET - SDH ADM and E1/T1- PDH multiservice DACS 6U height, full front access (ETSI) shelf TM, ADM and DCS at DS0, VC12, VC3, VC4 Dual STM-1/4 - OC-3/12
More information500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System
Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2
More informationLambda Driver Passive (LDP) 300
Lambda Driver Passive (LDP) 300 Installation Guide Standards Compliance UL 1950; CSA 22.2 No 950; FCC Part 15 Class A; CE-89/336/EEC, 73/23/EEC FCC Notice WARNING: This equipment has been tested and found
More informationPHB-200M PHB x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub
SFP Patching Hub PHB-200M PHB-200 20x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub PHB-200M is a 20-channel Managed SFP patching hub that converts copper 100/1000Base-TX to SFPs working at 100Mbps
More information10 Gigabit Ethernet Copper-to-Fiber Media Converter - Open SFP+ - Managed
10 Gigabit Ethernet Copper-to-Fiber Media Converter - Open SFP+ - Managed Product ID: ET10GSFP This 10GbE fiber media converter lets you scale your network using the 10Gb SFP+ transceiver that best suits
More informationDWDM Topologies CHAPTER. This chapter explains Cisco ONS dense wavelength division multiplexing (DWDM) topologies.
CHAPTER 12 This chapter explains Cisco ONS 15454 dense wavelength division multiplexing (DWDM) topologies. Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature.
More informationChassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.
This chapter provides an overview of the Cisco NCS 4016 chassis and components. About the Cisco NCS 4016 Chassis, page 1 Chassis Components, page 6 Chassis Cable Management, page 11 Safety Guidelines,
More informationEKINOPS 360. Dynamic Optical Transport for Metro, Regional and Long Haul SMALL FORM FACTOR LOW-POWER CONSUMPTION LEADING EDGE TECHNOLOGY
D ETAILED P RODUCT B ROCHURE SMALL FORM FACTOR LOW-POWER CONSUMPTION LEADING EDGE TECHNOLOGY Dynamic Optical Transport for Metro, Regional and Long Haul Economical 40G and 100G in the Near Term Lowering
More informationNext Generation Firewall
Next Generation Firewall Hardware Guide Models 110, 115 Revision A Contents Introduction on page 2 Find product documentation on page 2 Model N110 features on page 3 Model N115 features on page 5 Precautions
More informationMC 11 EB-2 Power supply cabinet with external bus, AC version
MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures
More informationTECHNICAL SPECIFICATION. Brocade 6510 Switch Technical Specifications
TECHNICAL SPECIFICATION Brocade 6510 Switch Technical Specifications 53-1003428-08 29 December 2017 Copyright 2017 Brocade Communications Systems LLC. All Rights Reserved. Brocade and the stylized B logo
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More information3+1 U CPCI Serial System
3+ U CPCI Serial System User s Manual Product Number: 4579-46/47/48/49/40/4/4/43/44 Doc-No: 6397-349_R.0 January 06 R.0 January 06 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt,
More informationTHE BEST LOW-COST CAPACITY BOOST FOR ACCESS NETWORKS IS ALSO THE GREENEST
THE BEST LOW-COST CAPACITY BOOST FOR ACCESS NETWORKS IS ALSO THE GREENEST Infinera TG-Series 1 Need to Increase Your Access Network Capacity? The requirement for greater capacity is forcing network operators,
More informationSpecifications and Part Numbers
This appendix provides information on the part numbers of the router variants, SFP modules, product, power, and environmental specifications of the Cisco ASR 901S Series Aggregation Services Router components.
More informationORION TELECOM NETWORKS INC.
RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100,
More informationPIX 515/515E. PIX 515/515E Product Overview CHAPTER
CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses
More informationOver 70% of servers within a data center are not connected to Fibre Channel SANs for any of the following reasons:
Overview The provides modular multi-protocol SAN designs with increased scalability, stability and ROI on storage infrastructure. Over 70% of servers within a data center are not connected to Fibre Channel
More informationInstallation Job Aid for VSP 4850GTS
Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe
More informationINDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide
INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced
More informationUpdated in Free Product Guide for Your Network. WDM & FTTx. Catalog
Updated in 2017 Free Product Guide for Your Network WDM & FTTx Catalog FS.COM WDM & FTTx This catalog is a guide of FS.COM WDM & FTTH solutions. FS.COM self-develops a series of OTN (optical transport
More informationCisco ONS CL Shelf Assembly Hardware
CHAPTER 1 This chapter provides a description of Cisco ONS 15310-CL shelf hardware. Instructions for installing equipment are provided in the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.
More informationEMC1600 Series Media Converter and Ethernet Extender Chassis
EMC1600 Series Media Converter and Ethernet Extender Chassis User s Manual Preface This manual describes how to install and use the 16-Bay Media Converter and Ethernet Extender Chassis. This chassis is
More informationFiber Optic Components Dedicated to supplying industry standard fiber optic components!
Fiber Optic Components Dedicated to supplying industry standard fiber optic components! Authorized distribution provided in alliance with Sensible Micro Corporation 13520 Prestige Place Tampa, FL 33635
More informationCPCI System Subrack 1 U
User s Manual Product No.: Doc-No: 63972-165_R1.0 January 14, 2008 Rev. Date updated Change R1.0 January 14, 2008 Initial Release Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this
More informationDatasheet. 10G 16-Port Managed Aggregation Switch. Model: US-16-XG. Non-Blocking Throughput Switching. Maximum Performance and Low Latency
10G 16-Port Managed Aggregation Switch Model: US-16-XG Non-Blocking Throughput Switching Maximum Performance and Low Latency 10G Ethernet SFP+ and RJ45 Ports Deployment Example 10G Aggregation Switch for
More informationA.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications.
APPENDIX A Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring
More informationF8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO
F8008 Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet + optional V.35/QFXS/QFXO Description F8008 is a fiber optical multiplexer of new generation different from the traditional PDH, multiplexing 1 full
More informationSFP GIGABIT MANAGED SWITCH ECO
QUICK INSTALLATI GUIDE LGB5124A-R2, LGB5128A-R2 SFP GIGABIT MANAGED SWITCH ECO 24/7 AT OR VISIT BLACKBOX.COM + + RTN + -48V RST PWR AC PWR DC SYS ALM CSOLE 28-PORT GbE MANAGED SWITCH AC INPUT: 100-240
More informationSML40-CH04 Chassis CWDM Passive 4 Slot Rack
SML40-CH04 Chassis CWDM Passive 4 Slot Rack The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. CTC Union Technologies assumes
More informationConfiguring Optical Devices by Using the Chassis View
Configuring Optical Devices by Using the Chassis View Cisco EPN Manager 2.1.3 Job Aid Copyright Page THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT
More information