Lift Control System. Used in conjunction with the LMS-Platinum software & the LMS-Access Control System
|
|
- Sara Brown
- 5 years ago
- Views:
Transcription
1 Lift Control System Used in conjunction with the LMS-Platinum software & the LMS-Access Control System This is primarily designed to operate with standard physical push button lift Components: - Lift Control System Dimensions - Measurements - Electrical wiring diagram Revision Date: 15 January 2018 Copyrights Information in this document is subject to change without further notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the expressed written permission of KAS.
2 Page 2 1 KAS-Lift Control System (LCS) components The following diagram shows the components of the Lift Control System, which incorporates the Access Control Reader (ACR) and the Lift Control Module (LCM). KAS will have already setup the mode switch according to the client s specifications; please do not change these mode switch settings. The Lift Control Module (LCM) can be powered from 240V AC (as it has an internal transformer converting to 5V DC), or it can be powered directly from a separate 5V DC power source if preferred. 240V AC transformer will be supplied with each LCM. 240AV / 5V DC transformer 3 contact terminals for each Lift Button Access Control Reader (ACR) connecter bar Mode switch (as set by KAS) 3 contact terminals for each Lift Button
3 Page 3 2 Control dimensions Lift Control Module Model SN-910A Installation tip: The Lift Control Module (LCM) is generally installed on top of the roof of the lift cart, in close proximity to the rest of the lift system s electrical hardware. The LCM can also be installed inside the internal control panel inside each lift. This facilitates easy access to wire each control lift button. 3 Access Control Reader (ACR) dimensions The following diagram shows the dimensions of the Access Control Reader (ACR):
4 Page 4 4 Requirements for multiple LCM s Connect Controller (A) to Controller (B) Notes Using controller (A) only, you can have up to 16 floors. For more than 16 floors, a second lift controller (B) will be attached, doubling your level capacity to 32 floors. Recommended maximum distance between LCM and Reader: 60 metres
5 Page 5 5 Wiring diagram for LCM and ACR ACCESS CONTROL READER LEDGER ACCESS CONTROL READER
6 Page 6 6 Installation tips for LCS and ACR Lift button contact terminal There are 3 'contact terminals' for each Lift Button: 1) Join the "DOT" contact to one side of the original Lift Button 2) Remove the other wire from the Lift Button and join to one of the "+" contacts. 3) Run a new wire from the other "+" contact back to the second side of each Lift Button. Note: The symbols for the button contact terminals are on the outside stainless steel cover Summary of contact terminal setup for each lift button: + First terminal connected from the original Lift Button wire + Second terminal contact with a new replaced wire to Lift Button Terminal is to be joined with the other existing wire on the Lift Button See image on previous page for wiring diagram The output from the LCM is designed to connect to the standard switching wires/circuit for each of the push buttons in each lift, by allowing the associated push buttons in the lift to be selected according the permissions of the presented guest card. If a guest is not allowed to a certain
7 Page 7 floor, pushing the button on the lift to those non-permission floors will have no effect, thus not allowing that guest access to those floors. Our system is not designed to be used with the later model touch screen lifts, but rather the traditional (and more common) lifts that have a physical push button for each floor. Note: KAS strongly recommends wiring the Lift Control System with an isolation master switch, preferably controlled from reception, or at least the control room, whereby the LAC system can be isolated from a normal functioning lift where you could still push any button to get to any floor (ie Fail Safe). In this way, should there be any malfunction, the LAC can be isolated allowing continued access to all floors by any person, until the issue is resolved.
Bluetooth Lock System
Bluetooth Lock System Revision Date: 14 Mar 2018 COPYRIGHT: Information in this document is subject to change without further notice. No part of this document can be reproduced or transmitted in any form
More informationRevision Date: 1 Nov LMS-Platinum
Revision Date: 1 Nov 2017 LMS-Platinum LMS-Platinum Electronic Hotel Lock The LMS-Platinum represents the latest development in keyless electronic lock systems, offering accommodation providers a versatile,
More informationElectronic Lock System
Electronic Lock System COPYRIGHT: Information in this document is subject to change without further notice. No part of this document can be reproduced or transmitted in any form or by any means, electronic
More informationKAS Electronic Lock System. Product Catalogue
KAS Electronic Lock System Product Catalogue Revision date: 1 Nov 2017 LMS-Platinum Electronic Hotel Lock The KAS Platinum electronic lock is produced from high-quality stainless steel and uses the latest
More informationLMS - Platinum Reference Manual
LMS - Platinum Reference Manual Used in conjunction with the LMS-Platinum software Copyrights Information in this document is subject to change without further notice. No part of this document may not
More informationGuangdong Be-tech Security Systems Limited. Elevator Control Manual Instruction. Version 2013 Page1 total 22
Elevator Control Manual Instruction Version 2013 Page1 total 22 Content Guangdong Be-tech Security Systems Limited 1. Unit Dimensions... 3 1.1. Card reader board... 3 1.2. Relay board... 3 1.3. Relay box
More informationObservatory Automation Project
Observatory Automation Project Detail Design Review Control of Electric Dome Drive System Grant Matsushige/Steven Bauman Version 1.0 17 May 2010 1. Overview After the preliminary design review, it s been
More informationS1 Access Control Gateway Datasheet
S1 Access Control Gateway Datasheet Table of contents Information... 2 Technical Specifications... 2 Images... 2 Wiring and Cabling... 3 Option 1: LAN PoE (Preferred Option)... 3 Option 2: WIFI + GPO -
More informationNote - Head mechanism fail state will be the same as power failure choice.
RotaSec FOS 91 RotaSec FOS 91 Manual security Turnstile Technical Specifications Drive: Orientation: Hand operated Pass Left or Pass right Materials: Casework: 304 Grade grained stainless steel.. Rotor
More informationASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES
ASSEMBLY, INSTALLATION, AND REMOVAL OF S AND MODULES FOR 40 GHz COAXIAL S AND MODULES Table of Contents SECTION 1 INSTALLATION AND REMOVAL SECTION 2 MODULE INSTALLATION AND REMOVAL SECTION 3 CROSS REFERENCE
More informationWith INTRATONE, you can easily secure all kinds of access points. You choose the management mode
With INTRATONE, you can easily secure all kinds of access points (Car parks, isolated doors, pedestrian gates, etc.) You choose the management mode REAL-TIME and REMOTE USING GSM READ/WRITE MODE How does
More informationACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features
Audio Door Entry with Access Control ACTentry A5 Kit Audio Door Entry & Access Control Kit Each kit comprises a door entry panel intercom power supply unit ACTEntryA5ICOM-K ACTentry A5 Entry Panel Audio
More informationSPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120
DESIGN GUIDELINES PRESTO INSTALLATION & CONNECTIVITY PAGE 1 of 4 ELECTRICAL CONNECTIVITY AND WIRING Communications Conduits Conduits designated for Presto equipment data wiring shall be clearly identified
More informationRevision Date: 02 Mar 2018
KAS Bluetooth Locks HOMES AIRBNB OFFICES SHARED SPACE Revision Date: 02 Mar 2018 COPYRIGHT: Information in this document is subject to change without further notice. No part of this document can be reproduced
More informationBlackboard Transact Product Feature Summary
Blackboard Transact Product Feature Summary Blackboard Video Surveillance Release 4.3.0.28 Introduction...1 What is in the Product Feature Summary?...1 Implementation Impact and Actions...1 Production
More informationDesigning a new IEC substation architecture
Designing a new IEC 61850 substation architecture Gerrit Dogger Senior Product and Application Specialist Cooper Power Systems gerrit.dogger@cybectec.com Garry Tennese Station Integration Specialist Manitoba
More informationInstallation Considerations: Included: Not Included:
Installation Considerations: See the Setup Guide for any details related to the steps in this guide; such as power requirements, rack mounting considerations, and other more in-depth instructions. The
More informationGEARMOTORS AF MOTORS FOR INVERTER C-1
C-1 C-2 C-3 C-4 R R C-5 C-6 C-7 1.47 14.7 584Hz 438Hz 318Hz 270Hz 234Hz 206Hz 167Hz 140Hz 121Hz 100Hz 81.4Hz 68.6Hz 59.4Hz 49.2Hz 40.2Hz 33.7Hz 28.9Hz 24.5Hz 21.2Hz 17.9Hz 15.2Hz 12.8Hz 3.11 4.15 5.70
More informationINTRODUCTION CT87E FEATURES AND CONTROLS
INTRODUCTION The CT87E is a precision instrument used to monitor and record the presence or absence of voltage, light, or sound level such as what would be produced by an operating electric motor or compressor.
More informationAnalog Door Phone Model LUADS
Analog Door Phone Model LUADS Installation and Use Manual Telephone line powered Two-way, hands-free communication Vandal-resistant brushed stainless steel faceplate with mounting gasket and heavy-duty
More informationKAS LOCK-S V11 SOFTWARE OPERATION MANUAL
KAS LOCK-S V11 SOFTWARE OPERATION MANUAL Index 1 INTRODUCTION... 4 2 COMPUTER REQUIREMENTS... 5 2.1 Hardware Requirements... 5 2.2 Software Requirements... 5 3 SOFTWARE INSTALLATION... 5 4 INITIAL SOFTWARE
More informationUSB 2.0 DIGI-USB2 1-Port USB m Category 5e/6/6a/7 Extender Set with Flexible Power. User Manual. Revision
USB 2.0 DIGI-USB2 1-Port USB 2.0 100m Category 5e/6/6a/7 Extender Set with Flexible Power User Manual Revision 171213 Thank you for purchasing the USB 2.0 DIGI-USB2. Please read this guide thoroughly.
More informationACTsmart2 Product Range Operating and Installation Instructions
ACTsmart2 Product Range Operating and Installation Instructions 18-00045 Contents ORDERING INFORMATION......4 INSTALLATION NOTES......5 IMPORTANT......5 PRODUCT SPECIFICATION......5 30 SECOND PROGRAMMING
More informationsmar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.
smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp PS302P - Fieldbus Power
More informationInstallation & User Manual V1.0
Other products from GSD standalone products GSD also offers fully functional standalone door controls for less complex door management. This attractive design, with modern aesthestics, will complement
More informationSetting Up The Hikvision IP Intercom For The First Time
Setting Up The Hikvision IP Intercom For The First Time Introduction 01/03/2018 This tech note will step you though the steps to setting up the HikVision IP Intercom for the first time as a hardwired system.
More informationRevision date: 27/08/2017
Energy Saving Device with Data Identification Revision date: 27/08/2017 COPYRIGHT: Information in this document is subject to change without further notice. o part of this document may be reproduced or
More informationKey Switch. Document version: 1.5 (Updated 02 May 2017)
Key Switch Document version: 1.5 (Updated 02 May 2017) Contents ii Contents 1 Key Switch R10S.3... 4 2 Quick Guides...4 2.1 Controlling an Electric Lock...5 2.2 Controlling an Alarm System... 5 2.3 Controlling
More informationInstallation Considerations: Included: Not Included:
Installation Considerations: See the Setup Guide for any details related to the steps in this guide; such as power requirements, rack mounting considerations, and other more in-depth instructions. The
More informationBSX (Bell System Exchange) and DAX Digital Isolating Door Entry Systems
58 BSX (Bell System Exchange) and DAX Digital Isolating Door Entry Systems The BSX and DAX door entry systems are designed to overcome a common problem experienced in local authority and public housing
More informationTL-PA4026 KIT. Highlights
AV500 2-port Powerline Starter Kit Highlights HD Streaming Up to 500Mbps powerline speed ensures smooth HD stream transmission Energy Saving Mode Automatic Energy Saving mode reduces power consumption
More informationpanels S4-MIO2 SP02 panels buttons S4-PB05 16x16 dot digital floor indicator Speech processor with SD Micro card
2014 S4-MIO2 16x16 dot digital floor indicator SP02 Speech processor with SD Micro card panels Custommade panels in a variety of materials panels buttons Buttons in a variety of materials depending on
More informationUsing the ClockAudio CS 2S-RF with the Converge Pro
TECH NOTE PRODUCTS AFFECTED: All Converge Pro Products except the TH20 and VH20 CLEARONE DOCUMENT 801-000-000-00 (REVISION 1.0) May 2012 Using the ClockAudio CS 2S-RF with the Converge Pro OVERVIEW This
More informationNTS-protect. Description of GPS antenna and NTS time server connection via system lightning protector system /NTS-3000, NTS-4000, NTS-5000/
NTS-protect Description of GPS antenna and NTS time server connection via system lightning protector system /NTS-3000, NTS-4000, NTS-5000/ SAFETY INSTRUCTIONS! This are the important Safety Instructions
More informationMeter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)
Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M9813380120-A) 1.- BASIC INSTRUCTIONS 1.1.- Checks on receipt. This manual assists in the installation and handling of
More informationThe L-1 Series Emergency Phone
Product Manual Product Number: L1 SERIES Line Powered ADA Emergency s The L-1 Series Emergency Line Powered ADA Emergency s A17.1 2013 & ADA Compliant Solutions Emergency ADA for Elevators, Area of Rescue,
More informationNEW! Aiphone IX System
NEW! Aiphone IX System Combining video entry security, internal communication, emergency stations and multicast paging. VIDEO DOOR ENTRY SYSTEMS 2018 Catalogue New for 2018 Aiphone s IX integrated IP intercom
More informationTYMIN INDUSTRIES LIMITE Dan Chou Tel: (00) ProUSB Card Lock Management Software
ProUSB Card Lock Management Software Main feature: 1. Overview about the lock/system Work with stable hotel lock system unlock by card and mechanical keys Unique hidden mechanical key hole design American
More informationCatalog. IP video door intercom system for smartphones and tablets (ios, Android)
Catalog IP video door intercom system for smartphones and tablets (ios, Android) myintercom in action... 1. Surf the Internet in the garden 2. The driveway entrance bell rings* 3. "I'll open for you."
More informationSensacell Troubleshooting Guide
A ONLY SOME MODULES LIGHT UP B PANEL DOES NOT LIGHT UP Only some modules light up Panel does not light up Check jumpers and power wiring AC Power present at Power Supply input terminals? Check AC Line
More informationTelephone Switch Module. Model# TSM-1. User Guide. Santa Clara, CA (800) (972)
Telephone Switch Module Model# TSM-1 User Guide Santa Clara, CA 95050 1(800) 879-8585 1(972)578-1699 DESCRIPTION The Telephone Switch Module (TSM-1) allows any touch-tone phone to control lights. The TSM
More information2504 Controller. user s manual. Part# Martin Professional A/S
2504 Controller user s manual 1996 Martin Professional A/S Part# 510150 1996 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means,
More informationFile E Project 12SC February 9, 2013 REPORT. Component - Protectors, Low-voltage Solid-state Overcurrent
File E211395 Project 12SC04547 February 9, 2013 REPORT On Component - Protectors, Low-voltage Solid-state Overcurrent Copyright 2013 UL LLC MAXIM INTEGRATED PRODUCTS AUSTIN, TX 78729 UL LLC authorizes
More informationINSTRUCTION MANUAL A141 High Level Audible Warning System
24V DC (18V to 30V DC range) 115 or 230VAC (90V to 264V AC range) Operating Temp: -20 to +55 C IP Rating: IP65 Marking: 3) Installation Requirements 1) Introduction The A141 high level audible warning
More informationBHD-8000 Access Control Keypad and Card Reader. Wiring Diagram
BHD-8000 Access Control Keypad and Card Reader Wiring Diagram Frontal View Main Technical Specifications Item Operating Voltage Unlock Relay Operating Temperature Value 12VDC+12%/1.2A 12VDC/2A Normal Operation:
More informationBS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0
BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY
More informationFitting Ah-ha to a machine using Gecko Stepper drives
Fitting Ah-ha to a machine using Gecko Stepper drives Please note these instructions are for guidance. If you have any doubt on any particular point please check with us. If you have any difficulties in
More informationiloq S10 Online Configuration Guide
iloq S10 Online Configuration Guide Document version: 1.5 (Updated 02 May 2017) Contents 1 S10 Online System... 3 1.1 Printable Documentation... 4 1.2 Licenses...4 1.3 Net Bridge N100...4 1.3.1 Net Bridge
More informationSection A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment
April 2015 PRICE SCHEDULE A 2.0 Section A5 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. Prices and specifications subject to change without
More informationPower Supply, 17-inch
apple imac G5 Power Supply, 17-inch Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note:
More informationLC18. Specification: Product Overview. Touch Screen
LC18 Product Overview LC18 Specification: Material: Aluminum front panel, 1.5mm aluminum body Color: Black & Silver Motherboard: ATX, Micro ATX Drive Bay: External - 5.25" x 2 External - 3.5" x 1 Internal
More informationRapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS
Rapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS RAPIER GX Gas Enclosed Switch Our new RAPIER GX, pole-mounted
More informationEVLA Vertex Room (and other mechanical considerations)
Racks, Bins & Modules PDR Paul Harden 17 June 2002 EVLA Vertex Room (and other mechanical considerations) This file has been modified from the original presentation. It has been changed from the standard
More informationExpressCard Instant Issuance Card Personalization System Ethernet Jack Replacement Procedure. September 22, 2014
ExpressCard 2000 Instant Issuance Card Personalization System Ethernet Jack Replacement Procedure September 22, 2014 Manual Part Number: 99875721-1.01 REGISTERED TO ISO 9001:2008 MagTek I 1710 Apollo Court
More informationBasic Electricity 10 Hour - Part 1 Student Workbook Issue: US140/10/2a-IQ-0402A. Written by: LJ Technical Dept
Basic Electricity 10 Hour - Part 1 Issue: US140/10/2a-IQ-0402A Copyright 2004,. No part of this Publication may be adapted or reproduced in any material form, without the prior written permission of. Written
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationHard Drive, 20-inch. Replacement Instructions
apple imac G5 Hard Drive, 20-inch Replacement Instructions Follow the instructions in this document carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note:
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informationThe HAUSSMANN RIRI keypad
The HAUSSMANN RIRI keypad YOUR HAUSSMANN RIRI KEYPAD IS EVOLVING Until now, you could only use the keypad itself, but now it is possible to connect other equipment to it enabling you to control keypad
More informationSMART Board Interactive Display Model 8070i
PLEASE THINK BEFORE YOU PRINT SMART Board Interactive Display Model 8070i Installation Guide Trademark Notice SMART Board, DViT, SMART Notebook, SMART Meeting Pro Premium, smarttech and the SMART logo
More informationSecurefast SPECIFICATION MANUAL. Entra Access Control. Part of the Securefast Group SECUREFAST DEEDLOCK PINSON TATE COLSON. securefast.co.uk.
CI/SfB (68.5) Securefast Entra Access Control securefast.co.uk SPECIFICATION MANUAL SECUREFAST Part of the Securefast Group DEEDLOCK PINSON TATE COLSON 2 Entra access control - Controllers Introduction
More informationPower Cable. Low-Voltage Cable
Troubleshooting Guide Power Cable Low-Voltage Cable Wire Manager Power Supply Driveshaft Driveshaft Cover Master Motor (can be on either side) Controller Controller Cable Lifting Column Foot Stretcher
More informationHUMAN/MACHINE INTERFACES & MONITORS
Challenger PC Terminals are an optimum solution for demanding tasks in on-site operation and visualization in Zone 1 / 2 / 22 hazardous areas. In the SAFE area the Challenger transmission unit picks up
More informationWaterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)
Touch & No Touch Exit Buttons s Infra-Red No Touch Exit Buttons ADB-11-CO (No Touch)/ ADB-13-CO (Hand icon) - 86x86x39mm - Sensing distance: 0.1-15cm - Installation: use with 86*86 back box ADB-12-CO (No
More informationNetwork Camera. Installation Manual Before operating the unit, please read this manual thoroughly and retain it for future reference.
C-357-100-11 (1) Network Camera Installation Manual Before operating the unit, please read this manual thoroughly and retain it for future reference. SNC-VB770 2016 Sony Corporation Table of Contents About
More informationSchematic Diagrams In this session, the schematic diagrams and control panel layout are covered. The control panel is 21 wide by 27 tall, and
s In this session, the schematic diagrams and control panel layout are covered. The control panel is 21 wide by 27 tall, and typically it would be housed in a 24 wide by 30 tall enclosure. For our demonstration
More informationLIFT CONTROL WITH FLOOR BUTTON FEEDBACK (V3 OR LATER)
Applications Programming Guide - LIFT CONTROL WITH BUTTON FEEDBACK. Rev 4.51 Page 1 LIFT CONTROL WITH FLOOR BUTTON FEEDBACK (V3 OR LATER) Lift control logic can be used to control Floor security for a
More informationBluetooth Shielding Instructions
Mac mini 2012 Bluetooth Shielding Instructions 1 INTRODUCTION 1.1 STATIC PRECAUTIONS 1.2 TOOLS REQUIRED 2 DISASSEMBLY 3 SHIELDING 4 FAQ 4.1 FAQ 5 CUSTOMER SERVICE 5.1 Before Contacting Customer Service
More informationDSC POWERSERIES NEO INTEGRATION. This application note will explain how to setup the DSC PowerSeries NEO integration on a KT-400 or a KT-1-M
DN NUMBER HERE DSC POWERSERIES NEO INTEGRATION This application note will explain how to setup the DSC PowerSeries NEO integration on a KT-400 or a KT-1-M Minimum Requirements: EntraPass Special, Corporate,
More informationInstallation Guide UD70 MD29. Second Processor Options for Unidrive and Mentor II. Part Number: Issue Number: 3.
EF Installation Guide UD70 MD29 Second Processor Options for Unidrive and Mentor II Part Number: 0460-0098 Safety Information The option card and its associated drive are intended as components for professional
More informationT8800 series BACnet MS/TP Networked Thermostat Controller
T8800 series BACnet MS/TP Networked Thermostat Controller Technical Bulletin Contents Revision... 2 1. Introduction... 3 2 Configuring MS/TP... 3 2.1 Wiring the network... 3 2.2 End-of-Line termination...
More informationQUICK START GUIDE. Microsoft Windows 10 / 8.1 / 8 / 7 / Vista / Home Server 2011
QUICK START GUIDE Microsoft Windows 10 / 8.1 / 8 / 7 / Vista / Home Server 2011 ESET Smart Security Premium is all-in-one Internet security software. It keeps you safe online and offline - and includes
More information= 1.0 meter. 50 = 5.0 meter. 90 = 9.0 meter. 95 = 9.5 in. NOTE: Highlighted lengths are stocked for shorter lead times
DP1007 Series Intrinsically Safe, PRO 11 mm, 1/2 20 Case Thread, Eddy Current/s with Jacketed Cable PRO DP1007 series proximity probes measure shaft vibration and displacement on Class I Zone 0 A Ga 11
More informationAV1200 TL-PA8010 KIT. Gigabit Powerline Starter Kit. Highlights
AV1200 Gigabit Powerline Starter Kit Highlights AV1200 HomePlug AV2 standard compliant, high-speed data transfer rates of up to 1200Mbps, supports all your online needs MIMO Technology Line-Neutral/Line-Ground
More informationReaders and Keypads 1
Readers and Keypads 1 Paxton readers Due to the wide range of site requirements, Paxton offers an extensive range of readers and keypads for use with our Switch2 and Net2 systems. This booklet gives an
More informationPOWERWISE INDAC SETUP MANUAL
POWERWISE INDAC SETUP MANUAL REVISION: 2.2 INDAC & EMONITOR GATEWAY An installation guide for the PowerWise indac. 2013 PowerWise, Inc. This manual may contain proprietary information about the product
More informationDECA PRINTER INTERFACE ACCESS CONTROL SYSTEMS INSTALLATION AND PROGRAMMING INSTRUCTIONS SYSTEM DESIGN
DECA ACCESS CONTROL SYSTEMS PRINTER INTERFACE INSTALLATION AND PROGRAMMING INSTRUCTIONS ISSUE : 001/UK REF : PRINT.PPP DECA PRINTER INTERFACE - FRONT PANEL MAIN FEATURES PARALLEL PRINTER 25 PIN (D TYPE)
More informationUSER MANUAL. Longo programmable controller LPC-2.CA1M Card Reader module. Version 2
USER MANUAL Longo programmable controller LPC-2.CA1M Card Reader module Version 2 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0)5 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si
More informationPush button sensor 3 design. 1 Introduction
1 Introduction Introduction: The push button sensor 3 is the operating unit on site in the wall, which makes it the operating unit which is always available to the user. It can be assigned different variants
More informationUSER MANUAL. Longo programmable controller LPC-2.CH1M Card Holder module. Version 3
USER MANUAL Longo programmable controller LPC-2.CH1M Card Holder module Version 3 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0)5 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si
More informationAV500 TL-WPA4530 KIT. Powerline ac Wi-Fi Kit. Highlights
AV500 Powerline ac Wi-Fi Kit Highlights HomePlug AV Provides up to 500Mbps high speed data transmission over a home s existing electrical wiring, ideal for lag-free HD or 3D video streaming and online
More informationIntegration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution.
Technical Datasheet Tier Power Systems, Inc. iq Series UL 1558 Switchgear Tier Power Systems iq Series is a leader in switchgear technology. iq Series provides advanced power distribution technology and
More informationiloq R10S.3.X KEY SWITCH (RELAY CARD + KEY READER)
1 iloq R10S.3.X KEY SWITCH (RELAY CARD + KEY READER) General The iloq R10S.3 Key Switch has been developed for easy control of peripheral systems by the iloq K10S key. The same iloq Key used for opening
More informationCF 1-1 Portable Copier CF121
CF 1-1 Portable Copier CF121 User Manual V1.0 Index Product Disclaimer... 3 Warranty... 3 Piracy Statement... 3 Important Notice... 4 Notice Symbols... 4 Product Overview... 5 Hardware Overview... 6 Function
More informationPRODUCT DETAILS. PRODUCT SPECIFICATIONS 316 Stainless Steel Up/Down Wall Pillar Lights
316 Stainless Steel Material: 316 Stainless Steel Colour: Stainless Steel HV1005C 6000K 2 x 500lm 60 2 x 10w GU10 LED HV1005W 3000K 2 x 460lm 60 2 x 10w GU10 LED HV1006 HV1007GU10C 6000K 2 x 300lm 120
More informationPreparing for the NBN. Fixed Wireless Connections
Preparing for the NBN Fixed Wireless Connections Preparing for the NBN Congratulations on choosing to join the National Broadband Network Your new fixed wireless connection will give you access to world-class
More informationDecorative Flat Plate Electrical Accessories in Various Plate Finishes Issue 5
Decorative Flat Plate Electrical Accessories in Various Plate Finishes Issue 5 Switches Sockets Connection Units Fan Isolation Switches Blank Plates Cooker Control Panels Telephone and Data Outlets Coaxial
More informationNEW. Bticino modular entrance panels. Sfera. CHOOSE YOUR FINISH Replace the dots in the Cat. No. with either 1, 2, or 3 to select the desired finish
Bticino modular entrance panels Sfera NEW Dimensions p. 33 FINISHES INSTALLATION TYPE FLUSH MOUNTING BOXES RAINSHIELDS (OPTIONAL) 1, 2 FRAMES / PLATES (2) CHOOSE YOUR FINISH Replace the dots in the Cat.
More informationAironet and WLAN Controller Product Power Options
Aironet and WLAN Controller Product Power Options Document ID: 21480 Contents Introduction Prerequisites Requirements Components Used Conventions Cisco Discovery Protocol Power Options Aironet 350 Series
More informationUser Guide. IP-COM WiFi App for AC1200 Enterprise Mesh WiFi System
User Guide IP-COM WiFi App for AC1200 Enterprise Mesh WiFi System I Copyright Statement 2018 IP-COM Networks Co., Ltd. All rights reserved. is the registered trademark of IP-COM Networks Co., Ltd. Other
More informationC e l l C O M. G S M I n t e r c o m
C e l l C O M G S M I n t e r c o m Call fixed line phone GSM SIGNAL Call mobile cell phone Accepts any GSM SIM card. Quad band modem. 850 / 900 / 1800 / 1900 MHz Calls up to 3 numbers in sequence GSM
More informationTRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights
HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated
More informationWiring Inside the card reader you will see a circuit board. The connections are as follows:
Power Adaptor (12VDC, Max. Current: 1A) If you purchased the Cardlock Series power supply cut the head of the adaptor and strip the insulation. If your locking mechanism, electric strike or magnetic lock
More informationpro ACTpro IOM INPUT/OUTPUT MODULE Installation and Configuration Instructions for the ACTpro IOM Input/Output Module ACT Product Code: ACTPRO IOM
pro ACTpro IOM INPUT/OUTPUT MODULE Installation and Configuration Instructions for the ACTpro IOM Input/Output Module ACT Product Code: ACTPRO IOM pro CONTENTS Technical Specification... 4 Product Overview...
More informationUSER MANUAL. Longo programmable controller LPC-2.SM6 Multisensor. Version 4
USER MANUAL Longo programmable controller LPC-2.SM6 Multisensor Version 4 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si Written
More informationInstallation Instructions
Installation Instructions For WiFi-Predator 1 P a g e Index Section Pages Android Configuration 3-6 iphone Configuration 7-10 Range and range testing 11-12 Installation 13 Power Supply 13 Wiring 14 Relay
More informationAllen-Bradley Drives
Installation Data This document provides information on: important pre installation considerations power supply requirements installing the module installing and connecting the wiring using the module
More informationPhone Installation. Phone Installation Overview. Cisco Unified IP Phone Cable Installation
Overview, page 1 Cisco Unified IP Phone Cable Installation, page 1 Wired and Wireless Headsets, page 4 Overview Your system administrator will likely connect your new Cisco Unified IP Phone to the corporate
More informationMasterpact NW Restricted Earth Fault Protection
Masterpact NW Restricted Earth Fault Protection Date: November 2011 Page 1 of 12 Contents Introduction 3 Principle of Operation 4 Equipment Required 5 Installation of the Neutral CT 5 Connection of the
More information