E R A I GATE AUTOMATION DIVISION

Size: px
Start display at page:

Download "E R A I GATE AUTOMATION DIVISION"

Transcription

1 S E R A I GATE AUTOMATI DIVISI INSTALLATI MANUAL KIT/30 F - SR F - KIT WITH 2 MOTORS FOR SWING GATES UP TO METERS AND 300 kg PER LEAF Vac KIT/39 F - SR F - KIT WITH 2 MOTORS FOR SWING GATES UP TO METERS AND 200 kg PER LEAF Vac Thank you for choosing a SERAI ELETTRICA product, which we are confident will perform to your requirements. Please be advised that you are about to fit a system classified as a power-operated drive designed to move automatic gates and doors in commercial or residential buildings accessed by vehicles and persons, and as such, the system must be considered potentially hazardous. By law, you are responsible for rendering this equipment as safe as is reasonably possible. Installation and maintenance of equipment of this kind must therefore be carried out by skilled, qualified and trained personnel, working in a professional manner, as provided for by law n. 37/08 and any subsequent amendments and supplements. The law in question prohibits the construction of these types of systems by non-qualified personnel. SERAI manufacturing complies with the following legislation: Applicable directives for the CE marking : Machines: Low Voltage: Electromagnetic Compatibility: General applicable standards: Electrical Safety: Electromagnetic Compatibility - Emissions: Electromagnetic Compatibility - Immunity: 2006/2/EC 2006/95/EEC 200/108/EEC IEC EN IEC EN CEI EN CEI EN Apart from the legislation mentioned above, you are also reminded to comply with the following standards during the installation phase. General applicable standards: Safety of electrical systems in non-specialised environments: CEI 6-8 V2 Specific product standards applicable: Safety in the use of power-operated doors - requirements: UNI EN1253 Safety in the use of power-operated doors - testing methods: UNI EN125 SERAI products enable users to build systems which comply with these standards. This is extremely important as THE INSTALLER IS LIABLE FOR THE SYSTEM AND FOR ENSURING ITS OPERATI COMPLIES WITH LEGAL PROVISIS. This handbook must be read in full before proceeding with the installation of the various parts of the system. The installation of the mechanical end stops for gate opening and closure is necessary for system safety purposes and therefore this operation must be performed before proceeding with the installation of the control unit. Page 1/18

2 Attenzione Limite di corsa. Non superare Caution Limit of stroke. Do not exceed Attenzione Limite di corsa. Non superare Caution Limit of stroke. Do not exceed Motors MT/30/2 = KIT/30F MT/38/1 = KIT/39F COMPENTS OF KIT KIT/30F KIT/39F 2 2 CR/1 OG/62 Electronic control unit with built-in receiver 2-channel minitransmitter with marsupium support M/10 Electric key 1 1 P/10 Pair of impact-resistant photocells 1 1 RZ/20 F Flashing light with builtin antenna, without internal circuit for flashing 1 1 RZ/99 L-shaped holder 1 1 N. BRACKETS SET+ N. 2 CAPACITORS x 2 x 1 1 UNLOCKING KEY 1 1 OVERALL DIMENSIS OF GEARMOTOR LATERAL VIEW 115 mm 80 mm 860 mm (MT/30/2) 660 mm (MT/38/1) VIEW FROM BELOW 280 mm 60 mm 60 mm 950 mm (MT/30/2) Pag. 2/ mm (MT/38/1) DAL 1965

3 SYSTEM TYPE 6 RG58 2 X 1, x 0,5 2 x 0, x 1,5 3 x 1,5 230V 3 x 1,5 x 0,5 2 x 0,5 x 0,5 1 MT/30/2, MT/38/1 gearmotor 2 CR/1 electronic control unit with built-in receiver 3 OG/62 2-channel minitransmitter M/10 electric key 5 Pair of P/10 photocells 6 RZ/20 F Flashing light with antenna Advice for wiring up in non-specialised environments. 1. Fit an omnipolar switch upstream of the system, choosing one with a gap of at least 3mm between the contacts. Or, alternatively, use a 10A thermal magnetic circuit breaker. 2. Always make connections, of any type, with the system disconnected from the power supply, i.e. with the main switch set to OFF (symbol 0 ). The control unit, in particular, must never be connected to the power supply either during the wiring up, or when fitting any expansion boards. 3. The following cables must be used for installation of the system: for the control unit, motor and electric lock power supplies: 1.5mm section for lengths of up to 19m, 2.5mm section for lengths of up to 31m, for the flashing light: 0.75mm section for lengths of up to 3m, 1.5mm section for lengths of up to 19m, - for the low voltage and current lines, (e.g. for the photocells, control buttons, electromechanical key, sensitive 2 2 edges and other safety devices: 0.5mm section for lengths of up to 50m, 0.75mm section for lengths of up to 100m.. Wire up the earth connection in compliance with legal provisions. GEARMOTOR TECHNICAL SPECIFICATIS MT/30/2 MT/38/1 Power supply 230 V~ ±10% 50/60 Hz 230V~ ±10% - 50/60 Hz Max. leaf length 3,00 m 2,00 m Max. leaf weight 300 kg 200 kg Max. opening angle Max. absorption 1,6 A 1,6 A Power 150 W 150 W Max. torque 180 Nm 120 Nm Max. thrust 1200 N 1200 N Angular speed 0,09 rad/s 0,11 rad/s Opening time for s 17 s Motor force adjusted: via power supply voltage control Capacitor 12,5µF 12,5µF Motor thermal protection Protection rating IP55 IP55 Operating temperature -20 C +60 C -20 C +60 C Dimensions 950 x 115 x 80 mm 750 x 115 x 80 mm Weight 9 kg 7,5 kg The technical data refer to an ambient temperature of 25 C with intermediate force setting. Lower operating temperatures or higher stress levels could require increased force settings. The opposite applies for higher temperatures or lower stress levels. DAL 1965 Pag. 3/18

4 Attenzione Limite di corsa. Non superare Caution Limit of stroke. Do not exceed Attenzione Limite di corsa. Non superare Caution Limit of stroke. Do not exceed BEFORE INSTALLING THE MOTORS 1- Ensure perfect right angles of the gate hinges to enable totally smooth and balanced swing gate movement. Otherwise the motor may be damaged when subject to much higher levels of resistance with respect to those specified for intended use. 2- In the maximum gate opening and closing positions, check that two sturdy travel stops are anchored to the ground to block the gate leafs at the end of travel Fig Otherwise install as necessary. 3- Ensure that the distance between the gate hinge and post surface, marked A in fig. 2, is: - less than 130 mm for an opening angle of 90 - less than 110 mm for an opening angle of less than 80 mm for an opening angle of The motor is supplied with the mobile pin (PM) - Fig. 3 - in the correct position for installation. However, ensure that the distance of the mobile pin from the rear connection point is: mm for motors MT/30/ mm for motors MT/38/1. Any distance greater than the specified value may cause shutdown of the motor shortly before the gate reaches the closing end stop; shorter distances will cause a smaller opening angle than that required. Fig. 1 PILLAR A GATE HINGE OPENING AND CLOSING END STOP Fig. 2 LATERAL VIEW 115 mm 80 mm 860 mm (MT/30/2) 660 mm (MT/38/1) VIEW FROM BELOW 280 mm 60 mm 60 mm 950 mm (MT/30/2) 750 mm (MT/38/1) WARNING: NEVER EXCEED THE PIN STROKE LIMITS AS INDICATED THE MOTOR Attenzione Limite di corsa. Non superare Caution Limit of stroke. Do not exceed Pag. /18 Fig. 3 DAL 1965

5 5) Choose the opening angle and calculate distances B and C, -Fig. Fig. 5 and table for bracket positioning. The values in the grey band are recommended. The brackets can be resized (shortened or lengthened) according to assembly requirements, and observing distances B and C. N.B. In the case of outward opening, the overall working area of the gate is reduced due to the dimensions of the motors. In this case installation of the motors on the upper section of the gate is recommended. IMPORTANT : Failure to observe distances B and C specified in the table will mean that the gate starts movement suddenly with excessive oscillations which could lead to damage to the brackets and motor. BRACKET POSITIING FOR INWARD OPENING BRACKET POSITIING FOR OUTWARD OPENING C PM B 860 mm (MT/30/2) 660mm (MT/38/1) 90 mm OUTWARD OPENING INWARD OPENING PM C B Fig. Fig mm (MT/30/2) 380mm (MT/38/1) 90 mm OPENING ANGLE 90 OPENING ANGLE 100 OPENING ANGLE 110 B C B C B C Warning: to ensure correct gate movement, use values in the shaded band. The gate opening (or closing) time varies according to the selected values B and C. PROVISIAL MOTOR INSTALLATI 6- Close the gate completely. Provisionally fix the rear bracket - Fig. 6 onto the gate post by welding or by means of screws + plugs, observing distances B and C. Provisionally fix the motor to the rear bracket, As shown in Fig Move the motor up against the closed leaf to determine the front bracket welding point. Move the motor away from the leaf. Provisionally fix the front bracket to the gate, observing the distance and travel limits of the mobile pin. Insert the mobile pin in the front bracket fig. 7 then secure by means of the nut. Fig. 6 PM DAL 1965 Fig. 7 Pag. 5/18

6 8- Level the motor and tighten all screws and bolts fully down. Fig With the aid of a 17 mm wrench, turn the half-nut on the mobile pin through half a turn to release the motors. Fig. 9. Check that movement is smooth. Return the half nut of the mobile pin to the original position. Close the gate: the motor blocks when the gate reaches the closing end stop. Fig. 8 Fig. 9 FINAL INSTALLATI 10- Remove the motor from the brackets. Weld the front bracket in its final position. Fix the rear bracket in its final position. Fig Refit the motor. 12- Mount the lever release mechanism, as shown in fig. 11. Remove the blank-out disk on the right (marked internally with D) for the right leaf, and remove the blank-out disk on the left (marked internally with S) for the left leaf. In the hole, insert the key block with protection cover. Secure the hook-shaped pawl by means of the relative nut onto the square pin of the key block. Close the half nut of the mobile pin between the two half-housings and secure by means of the relative screws. Fig. 10 MOTOR INSTALLATI LEFT GATE WING MOTOR INSTALLATI RIGHT GATE WING Fig. 11 MOVING THE GATE MANUALLY IN THE EVENT OF A POWER FAILURE - Use the key and release lever as shown in fig Keeping the mobile pin released by means of the release lever, open manually - Fig To restore the gate block, simply return the release lever and gate to the positions prior to release, pushing the gate until it engages - Fig Return the key to the initial position to remove - Fig. 15. Fig. 12 Fig. 13 Pag. 6/18 Fig. 1 Fig. 15 DAL 1965

7 CR/1 CTROL UNIT INSTALLATI CTROL UNIT POSITIING Position the equipment in the vicinity of the gate, to minimise the length of cables for connection to the rest of the system. For further protection against atmospheric agents, position the control unit under a canopy or for improved protection in an enclosure also fitted with two lateral walls. The equipment should also be installed at a height of at least 1.5 meters, to keep it out of the reach of children. The control unit leaves the factory with the cover positioned for opening from the left-hand side. To invert the cover opening side, proceed as follows: SETTING THE COVER FOR OPENING TO RIGHT WARNING: This operation must be performed before fixing the enclosure to the wall. Insert a slotted screwdriver in the hinge fixture slot at the rear of the base and lever the hinge connection tooth while pulling the cover up to remove. (see Fig. 1) Fig.1 Insert a slotted screwdriver in the hinge fixture slot on the front of the cover and lever off the hinge connection tooth while pulling up the hinge. (see Fig. 2) Fig.2 Refit the hinges on the right side of the base, inserting them in the relative seats with the connection teeth facing the interior of the enclosure, until they click into place (see Fig. 3). Fig.3 Page 7/18

8 WALL-MOUNTING THE CTROL UNIT Position the equipment in the vicinity of the gate, so that the length of the cables for connection to the rest of the system are as short as possible. Secure the control unit with the cable routing holes facing downwards. Ø 6 8 mm NO NO YES CABLE INLET For cable routing, the lower section of the enclosure is equipped with seats for cable clamps PG11 and PG 13.5 to be punched out when required. Cable routing CAUTI: Close all inlets securely to prevent the penetration of insects which may damage the control unit. Advice for wiring up in non-specialised environments. 1. Fit an omnipolar switch upstream of the system, choosing one with a gap of at least 3mm between the contacts. Or, alternatively, use a 10A thermal magnetic circuit breaker switch. 2. Make all types of connection with the system disconnected from the power, i.e. with the main switch set to OFF (symbol 0 ). The control unit, in particular, must never be connected to the power supply either during the wiring up, or when fitting any expansion cards. 3. The following cables must be used for installation of the system: 2 - for the control unit, motor and electric lock power supplies: 1.5mm section for lengths 2 of up to 19m, 2.5mm section for lengths of up to 31m, for the flashing light: 0.75mm section for lengths of up to 3m, 1.5mm section for lengths of up to 19m, - for the low voltage and current lines, (e.g. for the photocells, control buttons, 2 electromechanical key, sensitive edges and other safety devices: 0.5mm section for 2 lengths of up to 50m, 0.75mm section for lengths of up to 100m.. Wire up the earth connection in compliance with legal provisions. OPENING AND CLOSING THE BOX When opening the box, ensure that the hinges protrude sufficiently from the guide on the base to ensure that the cover remains open without obstructing control unit wiring operations. Always accompany the cover when closing until it returns completely inside the hinges, taking care that the seal is inserted correctly. Close the cover with the relative screws. Page 8/18

9 WIRING DIAGRAM DISCNECT THE POWER SUPPLY BEFORE WORKING THE WIRING SOG/ SW1 F SW2 Com +2 spia DL10 DL9 DL8 * ELECTRIC LOCK NOISE REDUCTI To reduce the noise of the electric lock it is possible to add an ordinary bridge rectifier 50V A connected as per below indicated diagram A B C SET BREAK WORK - POWER + PED START STOP FOTO FOTO AP FINE CH FINE AP F2 SUPPLEMENTARY RELAY 12Vac 230Vac TRANSFORMER 230/12Vac -SERAI TR/01- F N 230Vac 12Vac 12Vac ELECTRIC LOCK TYPE SERAI M/83/1 TRANSMITTER PEDESTRIAN START STOP 12Vac 2 Vac NA CLOSING PHOTOCELL NA NC RECEIVER NC NC NC COMM OPEN CLOSE COMM M1 PED OPEN CLOSE M2 OP. DELAY F N 230Vac ±10% 50/60Hz ~ BRIDGE RECTIFIER + - ELECTRIC LOCK TYPE SERAI M/83/1 12Vdc TRANSMITTER OPENING PHOTOCELL (or SENSITIVE EDGE) NC RECEIVER FLASHING LIGHT 230V~ COURTESY LIGHT 230V~ TERMINALS CNECTIS DESCRIPTI INPUT COMM PEDESTRIAN CTROL START CTROL STOP BUTT CLOSING PHOTOCELL OPENING PHOTOCELL / SENSITIVE EDGE DO NOT USE FLASHING LIGHT COURTESY LIGHT MOTOR M1 MOTOR M2 20 DO NOT USE POWER SUPPLY BUILT-IN 23-2 RECEIVER ANTENNA ELECTRIC LOCK COMMAND PHOTOCELL POWER SUPPLY GATE OPEN INDICATOR LIGHT Input common terminals. Pedestrian control input (NO contact). With DIP1 SW1 set to OFF only the leaf connected to M1 opens. With DIP1 SW1 set to the single leaf opens for 7s. Start command input (NO contact) controls opening and closing in step-step mode. Stop command input (NC contact); when pressed, blocks motor operation; if pressed during gate open pause time cancels automatic re-closure. Input for photocell active during closure only (NC contact). if obscured during closure, the gate stops and then opens again. With DIP SW2 set to OFF: input for photocell active during both closure and opening (NC contact). If obscured during opening, the gate stops, and resumes opening as soon as the photocell is free. If obscured during closing, the gate stops, and re-opens as soon as the photocell is free. With DIP SW2 : Sensitive edge input (NC contact); inverts movement by 10 cm. Short circuit on common with jumpers. Flashing light power output (230Vac-max 50W) to use with flashing light without internal electronics -type SERAI RZ/20 F-. Courtesy light output (230Vac-max 100W): active for 90 seconds after STOP M1 motor power output (1=Common, 15=Opening, 16=Closing) for single leaf or pedestrian access (connected to electric lock) M2 motor power output (17=Common, 18=Opening, 19=Closing) for motor delayed on opening (2-leaf gates) Card power supply input 230V~ ±10% 50/60 Hz Input for antenna connection for built-in receiver. (23=SHEATH, 2=ANTENNA) 12Vac 15VA max output for the direct command electric lock SERAI M/83/1. To reduce the noise it is possible to add a bridge rectifier as per diagram * 2Vac power output (max 500mA) for accessories such as photocells 2Vdc output (28 +, 29 -) max 50mA for gate open indicator connection. WARNING: to connect indicator lights with consumption of more than 50mA use a suitable supplementary external relay SW1= Microswitches for control unit setting - see microswitch settings - SW2= Microswitches for control unit setting - see microswitch settings - A= Button to enter programming mode (SET) B= Button for time programming (BREAK) C= Button for time programming (WORK) POWER= Trimmer for motor force adjustment FUSES: F1 = T1,6A 250V~ -slow acting- -ACCESSORIES 2V- F2 = 5A 250V~ -istant- -POWER SUPPLY 230V- SUPPLEMENTARY RELAY 2Vdc - max 50mA INDICATOR LIGHT INDICATOR LIGHT POWER SUPPLY Page 9/18

10 MOTOR FORCE ADJUSTMENT The motor force is adjusted by varying the power supply voltage via the Power potentiometer on the SERAI CR/1 control unit. In any event, installation must be in full observance with current standards governing power-operated gates; remember that the installer is responsible for the system and operation in compliance with standards. WARNING: the considerable differences in temperature between summer and winter can cause differing rates of expansion in all materials, including those used in the building of our motors. That is why we recommend you check the impact force setting at the start of winter and summer SOG/ SW1 A B C SW2 SET BREAK WORK F POWER + PED START STOP FOTO FOTO AP FINE CH FINE AP +2 Com spia DL10 DL9 DL8 F ELECTRIC CNECTIS OF MOTOR Connect the motors to the electronic control unit by means of cables 2 with a section of 1.5 mm. Observe terminal connections as follows: SKY BLUE : Common BLACK : Open/Close - Capacitor BROWN : Open/Close - Capacitor YELLOW/GREEN : Earth Observe the following: - Connect the motor earth (yellow-green cable) to an efficient earthing system. - Fit an omnipolar switch upstream of the system, choosing one with a gap of at least 3mm between the contacts. EARTH CNECTI BETWEEN MOTOR AND HOME SYSTEM NO SI 12,5 µf 50V YELLOW/GREEN = GROUND SKY BLUE = COMM BLACK = OPEN/CLOSE BROWN = OPEN/CLOSE MOTOR YELLOW-GREEN CABLES CNECTI TERMINAL HOME SYSTEM YELLOW-GREEN CABLE MOTOR 2 CABLE MOTOR 1 CABLE 230V POWER SUPPLY CABLE ATTENTI THE MOTORS MT/30/2 AND MT/38/1 ARRIVING AGAINST THE STOP BLOCK WHILE SLOWING DOWN ARE SUBJECTED TO VIBRATIS NOT DAMAGING BUT THAT MIGHT CAUSE SOME NOISE. IN ORDER TO AVOID THE NOISE: DEACTIVATE THE SLOWING DOWN FUNCTI DIP2 SW2 IN, PAGE 11-, IN THIS CASE THE LEAF ARRIVES AGAINST THE STOP BLOCK AT NORMAL SPEED Page 10/18

11 OPERATI MICROSWITCH SETTINGS SW1 SW2 SETTINGS OF EACH MICROSWITCH WARNING: Microswitches must only be adjusted when the control unit is disconnected from the power supply; any new microswitch settings are applied on subsequent start-up. After making new settings on microswitches, we recommend repeating the work time programming procedure (see control unit programming). DESCRIPTI OF OPERATI - Single leaf logic: only the output indicated with M1 is activated GATE CFIGURATI - Two-leaf logic: both outputs M1 and M2 are activated (M2 leaf delayed on opening) - High deceleration speed DECELERATI SPEED SETTING - Low deceleration speed WARNING: During deceleration, the force is reduced and therefore the speed depends on the characteristics of the motor and gate. AN EXCESSIVELY LOW DECELERATI SPEED COULD PREVENT SMOOTH LEAF MOVEMENT IF NECESSARY, DISABLE BY MEANS OF DIP2 OF SW2. FINAL CLOSURE STROKE - Final closure stroke active: at the end of the closing cycle, full power is applied for 2s to the motors to improve electric lock closure. - Final closure stroke not active. ELECTRIC LOCK RELEASE STROKE - Release stroke activated: the electric lock is activated during a brief phase of closure against the stops, and is deactivated shortly after start-up of M1. - Release stroke deactivated: the electric lock is activated shortly before start-up of M1, and is deactivated shortly after start-up of M1 START-UP TORQUE - Start-up torque activated: on start-up motors are powered up at the maximum voltage for 2s. RECOMMENDED ABOVE ALL IN WINTER - Start-up torque deactivated: on start-up motors are powered up at the voltage set by means of the potentiometer. WARNING: in this case there may be difficulties with startup above all if a low force level is set - Deceleration deactivated. DECELERATI SETTINGS - Deceleration activated. ATTENTI: The motors MT/30/2 and MT/38/1 arriving against the stop block while slowing down are subjected to vibrations not damaging but that might cause some noise. In order to avoid the noise: deactivate the slowing down function dip2 SW2 in -, in this case the leaf arrives against the stop block at normal speed Page 11/18

12 OPERATI MICROSWITCH SETTINGS SW 1 SW 2 DURING OPENING DESCRIPTI OF OPERATI - A start command sent during opening is ignored, while during the gate open pause causes closure. start COMMAND SENT DURING GATE MOVEMENT STEP-STEP FUNCTI DISABLED DURING CLOSURE DURING OPENING - A start command sent during closing causes the gate to stop for 2 and subsequent automation re-opening. start start 2 s - A start command sent during opening causes the gate to stop. - A subsequent start command closes the gate. start STEP-STEP FUNCTI ENABLED DURING CLOSURE - A start command sent during closing causes the gate to stop for 2 and subsequent automation re-opening. 2 s start INPUT OF OPENING PHOTOCELL OR SENSITIVE EDGE - Sensitive edge function activated: the input on terminal 6 both on opening and closing inverts movement by 10cm. - Opening photocell function activated: connect the photocells to terminal 6; if obscured during opening, the gate stops, and resumes opening as soon as the photocell is free. If obscured during closing, the gate stops, and re-opens as soon as the photocell is free. LED SIGNALS LED FUNCTI PED PEDESTRIAN button Pedestrian button pressed OFF Pedestrian button in normal status START Open/Close button Open/Close button pressed Open/Close button in normal status STOP FOTO FOTO AP Page 12/18 STOP button External photocell Internal photocell Stop button in normal status Closing photocell free of obstacles Opening photocell free of obstacles FINE CH Connection between terminals 8-10 OK FINE AP Connection between terminals 9-10 OK DL8 M2 motor control Brightness varies depending on the M2 motor control voltage DL9 M1 motor control Brightness varies depending on the M1 motor control voltage DL10 Programming Indicates the various programming phases Stop button pressed Closing photocell obscured (presence of obstacle) Opening photocell obscured (presence of obstacle) No jumper between terminals 8-10 No jumper between terminals 9-10 M2 Motor not powered M1 Motor not powered

13 CTROL UNIT PROGRAMMING Before proceeding with the programming, check that the system is equipped with all the electrical and safety devices (buttons, photocells, flashing lights, etc.), and that these are all connected. Ensure they all operate correctly: All the indicator LEDs for the NC inputs (stop, photocells, etc.) are lit. All the indicator LEDs for the NO inputs (start, pedestrian) are off. In the event of faults, ascertain and remove the cause. WARNING: Any unused normally closed (NC) inputs must be jumpered. It is important to follow the programming step by step; in the event of errors during this stage, a new programming session must be performed, in which case the new data will replace the previous data. To quit an incorrect programming session, switch the control unit off then on again. WORK AND DECELERATI TIME PROGRAMMING FOR TWO-LEAF GATES (DIP1 SW1 OFF) With the control unit powered and the gate closed, press the A (SET) key once to enter the programming mode. The DL10 LED starts flashing to indicate that the control unit is in the programming mode. Press the key C (WORK) once to start the opening phase of motor M1 (M2 remains stationary). Wait for a time interval equal to the offset to be applied to motor M2 in the opening phase (max. 15s), then press the key B (BREAK) once to start the opening phase of motor M2 (start up automatically after 15s). While both leafs are opening, set the motor power by means of the POWER potentiometer. WARNING: - If the POWER potentiometer is set too low, the gate may not open. We recommend setting POWER starting from the MAXIMUM value and gradually moving down to the minimum value. - The considerable differences in temperature between summer and winter can cause differing rates of expansion in all materials, including those used in the building of our motors. That is why we recommend you check the impact force setting at the start of winter and summer. When the leaf connected to M1 reaches the opening stop, let a few seconds pass (max. 3-s) and then press key C (WORK) once. Motor M1 is shut down. When the leaf connected to M2 reaches the opening stop, let a few seconds pass (max. 3-s) and then press key B (BREAK) once. Motor M2 is shut down. When the leafs are completely open and the motors are not powered, press the key B (BREAK) once to start the closure phase of motor M2 (M1 remains stationary). Wait for a time interval equal to the offset to be applied to motor M1 in the closing phase (max. 15s), then press the key C (WORK) once to start the closing phase of motor M1 (start up automatically after 15s). At the point in which motor M2 should start deceleration (at least 50cm before the stop is recommended) press the key B (BREAK). The motor M2 slows down. WARNING: skip this point if deceleration is disabled (DIP2 SW2 ) At the point in which motor M1 should start deceleration (at least 50cm before the stop is recommended) press the key C (WORK). The motor M1 slows down. WARNING: skip this point if deceleration is disabled (DIP2 SW2 ) When the leaf connected to M2 reaches the closing stop, let at least 5 seconds pass and then press key B (BREAK) once. Motor M2 is shut down. When the leaf connected to M1 reaches the closing stop, let at least 5 seconds pass and then press key C (WORK) once. Motor M1 is shut down and the control unit automatically exits the programming phase and is ready for normal operation. WARNING: - If one or more parameters are altered, programming must be repeated from the beginning. - In the programming procedure, deceleration has only been set in the closing phase, but is implemented also during the opening phase. Page13/18

14 WORK AND DECELERATI TIME PROGRAMMING FOR SINGLE LEAF GATES (DIP1 SW1 ) With the control unit powered and the gate closed, press the A (SET) key once to enter the programming mode. The DL10 LED starts flashing to indicate that the control unit is in the programming mode. Press the key C (WORK) once to start the opening phase of motor M1. While the leaf is opening, set the motor power by means of the potentiometer POWER. WARNING: - If the POWER potentiometer is set too low, the gate may not open. We recommend setting POWER starting from the MAXIMUM value and gradually moving down to the minimum value. - The considerable differences in temperature between summer and winter can cause differing rates of expansion in all materials, including those used in the building of our motors. That is why we recommend you check the impact force setting at the start of winter and summer. When the leaf reaches the opening stop, let a few seconds pass (max. 3-s ) and then press key C (WORK) once. Motor M1 is shut down. With the leaf completely open and motor not powered, press the key C (WORK) once to start the closing phase. At the point in which motor M1 should start deceleration (at least 50cm before the stop is recommended) press the key C (WORK). Motor M1 slows down. WARNING: skip this point if deceleration is disabled (DIP2 SW2 ) When the leaf reaches the closing stop, let at least 5 seconds pass and then press key C (WORK) once. Motor M1 is shut down and the control unit automatically exits the programming phase and is ready for normal operation. WARNING: - If one or more parameters are altered, programming must be repeated from the beginning. - In the programming procedure, deceleration has only been set in the closing phase, but is implemented also during the opening phase. GATE OPEN PAUSE TIME PROGRAMMING (AUTOMATIC RECLOSURE) ACTIVATING AUTOMATIC RECLOSURE (max time settable: 120s) With the control unit powered and the gate closed, press the A (SET) key once to enter the programming mode. The DL10 LED will start flashing, indicating that the control unit has entered the programming stage. Press the key B (BREAK) once, keeping it pressed until the flashing light comes on; the control unit will start the gate open pause count, which is indicated by the light flashing intermittently. Once the desired time has lapsed, press the key B (BREAK) again; the control unit will automatically store the amount of time between the two times the key B (BREAK) was pressed. It then quits the programming phase and switches to standard operation mode. If the key B (BREAK) is not pressed a second time within 120s, the control unit quits the programming, memorising the maximum time as 120s. DEACTIVATING AUTOMATIC RECLOSURE With the control unit powered and the gate closed, press the A (SET) key once to enter the programming mode. The DL10 LED will start flashing, indicating that the control unit has entered the programming stage. Press the key B (BREAK) and keep it pressed until the DL10 LED switches off. The control unit quits the programming phase and switches to standard operation mode. This operation deactivates the automatic reclosure function. Page 1/18

15 RADIO CTROL CODE LEARNING The electronic board incorporates a MHz 2-channel radio receiver which allows remote gate control via either the OG/02 and OG/0 series microswitch-operated radio controls, or the self-learning radio controls from the following series: OG/62, OG/6, OG/28, OG/8, OG/52, OG/5, OG/82/1 and OG/8. Both channels are used solely for gate control; more specifically, channel 1 of the radio receiver serves for the start function, while channel 2 is used for the pedestrian function. WARNING: - a mini transmitter must be programmed before it is used. - the maximum number of codes that can be stored is 32 for the open/close control + 32 for the pedestrian control (no other combinations, e.g. 0 open/close + 2 pedestrian etc, are possible). Let's have a look at two examples of storable codes: - example A: 32 self-learning mini transmitters from the following series: OG/62, OG/6, OG/28, OG/8, OG/52, OG/5, OG/82/1 and OG/8 as the start control (e.g. left-hand button) + 32 self-learning mini transmitters from the following series: OG/62, OG/6, OG/28, OG/8, OG/52, OG/5, OG/82/1 and OG/8 as the pedestrian control (e.g. right-hand button) - example B: 31 self-learning mini transmitters from the following series: OG/62, OG/6, OG/28, OG/8, OG/52, OG/5, OG/82/1 and OG/8 as the start control (e.g. left-hand button) + 1 OG/02 or OG/0 series microswitchoperated mini transmitter as the start control (there is no need to store the other OG/02 and OG/0 transmitters, simply set the microswitches in the same sequence as the one already stored) + 31 self-learning mini transmitters from the following series: OG/62, OG/6, OG/28, OG/8, OG/52, OG/5, OG/82/1 and OG/8 as the pedestrian control (e.g. the right-hand button) + 1 OG/02 or OG/0 microswitch-operated mini transmitter as pedestrian control (there is no need to store the other OG/02 and OG/0 transmitters, simply set the microswitches in the same sequence as the one already stored) WARNING: before proceeding with the mini transmitter programming or erasure phase, disconnect the antenna to prevent the receiver acquiring other signals during these phases which could impair automation operation. Reconnect the antenna once the procedures are complete. MICROSWITCH CFIGURATI (FOR OG/02 AND OG/0 MINI TRANSMITTERS LY) These instructions only apply if the OG/02 and OG/0 series microswitch-operated mini transmitters are fitted. Before performing the code learning procedure on the receiver, the factory configuration of the microswitches must be modified to prevent unwanted commands MODIFYING THE FACTORY SETTING TO PREVENT UNWANTED COMMANDS START CODE LEARNING - With the control unit powered and the gate closed, press the A (SET) key once to enter the programming mode. The DL10 LED starts flashing to indicate that the control unit is in the programming mode. - Press the button on the mini transmitter (e.g. the left-hand one) to serve as the start control, and keep it pressed until the DL10 LED switches off. The control unit stores the radio code received and automatically quits the programming phase, switching to the standard operation mode. PEDESTRIAN CODE LEARNING - With the control unit powered and the gate closed, press and hold down the A (SET) key to enter the programming mode. The DL10 LED starts flashing to indicate that the control unit is in the programming mode. - Keeping A (SET) pressed, press the button on the mini transmitter (e.g. the right-hand one) to serve as the pedestrian control, and keep the two buttons pressed until the DL10 LED switches off. The control unit stores the radio code received and automatically quits the programming phase, switching to the standard operation mode. - Repeat the procedure if several mini transmitters have to be stored. ERASURE OF STORED CODES All the radio codes stored in the memory can be erased by pressing the A (SET) key, and keeping it pressed until the DL10 LED switches off (approx. 10s) without sending any radio codes during this time. Page 15/18

16 EXPANDING THE NUMBER OF MINI TRANSMITTERS If the 32 mini transmitters storable in the built-in receiver are not sufficient, they can be increased by fitting the SOG/A receiver (which takes the number of mini transmitters up to 0), with the optional addition of the SOG/2A expansion board (which takes the number of mini transmitters up to 79). After fitting the SOG/A receiver, all the codes stored in the built-in receiver must be erased and all the mini transmitters on the new SOG/A receiver reprogrammed (see specific instructions). The antenna must be moved from the terminal on the control unit to the terminal on the SOG/A. DISCNECT THE POWER SUPPLY BEFORE WORKING THE WIRING SOG/ FIT THE SOG/A RECEIVER nd 2 CHANNEL OUTPUT: AUXILIARY CTROL NC NO NO C NC Channel 2 output (relay contact) Max. applicable voltage = 2Vac/dc Max. applicable current = 1A SW1 F SW2 - POWER + +2 Com spia DL10 DL9 DL8 st 1 CHANNEL OUTPUT: CTROL UNIT START CTROL PEDESTRIAN CTROL CR/1 -TERMINALS 1-2- OTHER A B C SET BREAK WORK PED START STOP FOTO FOTO AP FINE CH FINE AP F2 LIGHTS ANTENNA OTHER AUTOMATIS ELECTRIC LOCKS CR/1 CTROL UNIT TECHNICAL SPECIFICATIS Power supply: 230Vac ±10% 50/60Hz Motor power supply: 2 single-phase motor, 230Vac, 200W+200W Power supply for accessories: 2Vac, 500mA Flashing light power supply: 230Vac, max 50W Courtesy light power supply: 230Vac, max 100W Electric lock power supply: 12Vac 15VA Motor work time setting: from 0 to 120s Pause time setting: from to 120s Offset level on opening and closing: from 0 to 15s Operating temperature: -20 C +70 C Protection rating: IP5 Dimensions (H x L x D) and weight: Page 16/18 270x212x118mm, 1.7Kg

17 DIMENSIS POSITI P/10 PHOTOCELLS ALIGNMENT NO OK 90 mm 70 mm 0 mm LED INSTALLATI Ø 6mm CNECTIS THE CTACT POSITI REFERS TO WHEN THE RECEIVER IS ENERGIZED RECEIVER TRANSMITTER Ø 3.5mm The cable routing hole must be sized exactly for the cable to be passed through and no more POWER SUPPLY RELAY OUTPUT TX POWER SUPPLY PHOTOCELL TECHNICAL SPECIFICATIS Operating range - outdoor m - indoor m Power supply... 2 V~ ±10% TX absorption ma a 2 V-; 67 ma a 2 V~ absorption ma a 2 V-; 25 ma a 2 V~ Relay output... 1A 2 V~ Temperature C Dimensions...70 x 0 x 90 mm Weight g TX TX TX h MIN= 0 cm h MIN h MIN l = 10 m MAX l MAX NO TX OK TX SPHERICAL ORANGE LAMP WITH BUILT-IN MHz ANTENNA V~ RZ/20 F WHEN REPLACING LIGHT BULBS, ALWAYS USE 230 V MIN. 25W PEAR BULBS CNECTIS 230Vca NO 230Vca RG58 ANTENNA 2 x 0.75 mm² POWER SUPPLY CS/07 SR12.07 OPTIAL CABLE RZ/99 SR L-SHAPED HOLDER WARNING: WE RECOMMEND YOU POSITI THE POWER SUPPLY CABLE INSIDE A CDUIT WHICH IS NOT ACCESSIBLE BY THE USER. HOWEVER, IF SOME PARTS REMAIN ACCESSIBLE, THESE MUST HAVE DOUBLE INSULATI TOWARDS THE USER. CABLE CLAMPS MUST ALSO BE USED TO AVOID TEARING OF THE CABLE. Page 17/18

18 TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTI The gearmotor is not working No power supply to motors No power supply to control unit Check voltage presence on motor power supply input terminals Ensure that the power cable is not detached and is intact (cable replacement must be carried out by an authorised technician) Check the control unit fuses Check the mains fuse and presence of mains power voltage Motor thermal protection activated Incorrect motor force setting Leave the motor stationary for at least minutes and then check operation again Repeat programming, increasing the motor force by means of the potentiometer Power The gate does not complete its travel Gate blocked Unsuitable bracket position Ensure that there are no obstacles by moving the gate manually. Remove any obstacles if present. The brackets are not positioned according to values A, B, and C Incorrect work times Repeat the work time programming Incorrect deceleration settings Ensure that the set deceleration speed is sufficient to move the gate; if necessary disable deceleration (dip2 SW2 set to ) The gate is slow and start-up is problematic Capacitor failure Measure the capacitor capacity and replace if necessary Start-up torque deactivated Check the relative microswitch on the board The remote control range is reduced Unsuitable antenna connection External antenna required SOG/A receiver in use or at the Authorised Service Centres. Carriage costs shall be borne by the Customer. MADE IN ITALY VIA ENRICO FERMI, LEGNARO - PADOVA ELETTRICA PADOVA I I T A L I A Check that the antenna is connected correctly to terminals 23 and 2 To permit maximum reception distance, replace the internal antenna on the flashing light with an external one (SERAI OG/50 -SR 25.50) Replace the built-in receiver with the SOG/A card WEEE DIRECTIVE 2002/96/EC This appliance was manufactured after 13/08/2005. To protect the environment: when the equipment is no longer needed, take it to a special WEEE (Waste Electric and Electronic Equipment) collection centre. Do not dispose of it with normal household waste. CE CFORMITY DECLARATI SERAI spa declares that the product KIT/30F, KIT/39F has been desifned and manufactured according to the above mentioned directives and standards TERMS OF GUARANTEE The company reserves the right to make modifications to the equipment without prior notice thereof. SERAI products are covered by a standard guarantee with a term of 2 months. Coverage starts on the date on which the tax document constituting proof of purchase is issued and guarantee services shall be provided on the company's premises at Legnaro - PD - PHE FAX export@serai.com WEB AVf/r - IS KIT30F-IS-E

E R A I GATE AUTOMATION DIVISION

E R A I GATE AUTOMATION DIVISION S E R A I GATE AUTOMATI DIVISI INSTALLATI MANUAL MERCURIO 302CF SR 29.76 F KIT WITH ENCODER AND TOOTH RACK FOR SLIDING GATES (UP TO 300 kg -230Vac) CAUTI: - THE CTROL UNIT MUST BE PROGRAMMED PRIOR TO GATE

More information

E R A I INSTALLATION MANUAL. Gate Opener Department

E R A I INSTALLATION MANUAL. Gate Opener Department S E R A I Gate Opener Department INSTALLATI MANUAL MERCURIO 524A F SR 24.85/24A F KIT WITH ENCODER FOR SLIDING GATES UP TO 500 kg -24Vdc MERCURIO 524A H SR 24.84/24A MOTOR WITH CTROL UNIT FOR SLIDING GATES

More information

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual Q45 230V ac Control panel for electric rolling shutters 230Vac Built-in radio receiver 433Mhz Adjustable pause time for automatic closing function

More information

Control board for electromechanical gearmotors HERMES

Control board for electromechanical gearmotors HERMES Control board for electromechanical gearmotors HERMES 1 Attention! The present user manual is designed for personnel skilled in installation, not for the final user; the electrician is then due to inform

More information

MOOV-B400-24V ATTUATORE ELETTROMECCANICO IRREVERSIBILE 24V PER CANCELLI A BATTENTE. ISTRUZIONI D'USO E INSTALLAZIONE

MOOV-B400-24V ATTUATORE ELETTROMECCANICO IRREVERSIBILE 24V PER CANCELLI A BATTENTE. ISTRUZIONI D'USO E INSTALLAZIONE IL n. 390 EDIZ. 02/07/2013 ITALIANO MOOV-B400-24V I GB F E P ATTUATORE ELETTROMECCANICO IRREVERSIBILE 24V PER CANCELLI A BATTENTE. ISTRUZIONI D'USO E INSTALLAZIONE 24V IRREVERSIBLE ELECTROMECHANICAL ACTUATOR

More information

Tel Fax: Toll free:

Tel Fax: Toll free: ELECTRONIC CONTROL UNIT (cod. 2302B Series) for swing gates automation (Mini Tank Series) C5 Accessories power supply: 24V dc Max 200 ma T1 Trimmer regulation: Operating times Open pause time Leaf delay

More information

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 1 / SEAV LRS 2102 R ++ SET

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 1 / SEAV LRS 2102 R ++ SET CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 1 / SEAV LRS 2102 R ++ SET 230 Volt Single Phase logic control panel for single motor only sliding gate, roller garage door, single leaf swing gate Integral

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

CENTRALE DI COMANDO ANALOGICA

CENTRALE DI COMANDO ANALOGICA V2 S.p.A. Corso Principi di Piemonte, 65/67 12035 RACCONIGI (CN) ITALY tel. +39.0172.812411 - fax +39.0172.84050 info@gatestore.co.uk www.remotecontrolgates.co.uk Easy3-4 IL n. 207 EDIZ. 20/10/2010 I GB

More information

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide EnviroNET 2100 Series Ethernet Extender Quick Start Guide Important This is a Class A device and is intended for use in an industrial environment. It is not intended nor approved for use in a residential

More information

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK TARGHA 200 A/200N AGATA C200 UK Installation Manual AGATAKIT C 200 UK 24806770/28-05-2013 AGK200C03UK HPC/1 AGATA C200 UK AG2K200C03UK HPC/2 HA/200 HBP AG3K200C03UK HPC/3 A/200N AGK200C03HNA HPC/1+HNA

More information

SAFETY INFORMATION. Precautions to be observed for the choice and installation of the device

SAFETY INFORMATION. Precautions to be observed for the choice and installation of the device SG-BWS-T4-MT SERIES Safety control unit with double muting SAFETY INFORMATI QUICK GUIDE The following points must be observed for a correct and safe use of the safety light curtains of the SG-BWS-T4-MT

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky

More information

Robus 600/1000. Programmable functions using the Oview programmer. STF ROBUS Rev00 Firmware: RF02

Robus 600/1000. Programmable functions using the Oview programmer. STF ROBUS Rev00 Firmware: RF02 Robus 600/1000 Programmable functions using the Oview programmer STF ROBUS 600-1000 Rev00 Firmware: RF02 COMMON FUNCTIONS name This parameter enables the user to assign the automation with a name other

More information

Control panel installation manual for QIK80EH barrier. Safety switch 24V= ENC BIXMR2 COM PRG POWER. Automatic closing. Closing.

Control panel installation manual for QIK80EH barrier. Safety switch 24V= ENC BIXMR2 COM PRG POWER. Automatic closing. Closing. FUSE Ditec EL34 Control panel installation manual for QIK80EH barrier (Original instructions) IP2152EN Transformer Motor 24V= Safety switch TRF 24V~ EL34 12 11 0 ENC + M - BIXMR2 COM AUX AUX PRG GOL4 VA

More information

User Guide Automatic Transfer Switch (ATS)

User Guide Automatic Transfer Switch (ATS) User Guide Automatic Transfer Switch (ATS) V.1.0 Table of Contents 1. Introduction... 2 2. Product Overview... 2 3. Important Safety Warnings... 3 4. Operation Indicators & Status... 3 5. Installation...

More information

CB17 CONTROL SYSTEM USER MANUAL

CB17 CONTROL SYSTEM USER MANUAL CB1 CTROL SYSTEM USER MANUAL INDEX 1. CTROL BOX 2. CB1 CTORL PANEL LAYOUT AND WIRE CNECTI INDICATI 3. SYSTEM SET UP PROCEDURE 3.1 TRANSMITTER MEMORIZINGAND ERASING PROCESS 3.2 SYSTEM LEARNING PROCESS 3.3

More information

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811 95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing

More information

Please keep these instructions for further reference.

Please keep these instructions for further reference. C 4 / C 5 GB Instructions for Initial Operation and Wiring Scheme Manual Door Operator for Industrial Use Please keep these instructions for further reference. . Contents Chapter Page. Contents. Meaning

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

Q80A. 230V ac. CONTROL PANEL FOR DOUBLE/SINGLE SWING GATES Instructions Manual. Multi-function control panel for double/single swing gate - 230Vac

Q80A. 230V ac. CONTROL PANEL FOR DOUBLE/SINGLE SWING GATES Instructions Manual. Multi-function control panel for double/single swing gate - 230Vac CONTROL PANEL FOR DOUBLE/SINGLE SWING GATES Instructions Manual Q80A 230V ac Multi-function control panel for double/single swing gate - 230Vac Programming display Electronic adjustment of each motor s

More information

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815 95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-MON UNIVERSAL SAFETY PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales

More information

STYLO STYLO ME - STYLO RME English EN

STYLO STYLO ME - STYLO RME English EN 119DV11EN EXTERNAL OPERATOR FOR SWING GATES Installation manual STYLO STYLO ME - STYLO RME English EN EN CAUTION! important personal safety instructions: READ CAREFULLY! Foreword This product should only

More information

Installation Instructions

Installation Instructions LUCCI Slim Line Fan Remote Control SKU# 210012 Rated Voltage 220-240V~ 50Hz Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions

More information

DC Outdoor Power Supply/Chargers

DC Outdoor Power Supply/Chargers DC Outdoor Power Supply/Chargers Installation Guide Models Include: WayPoint3 WayPoint7-2.5A @ 12VDC or 24VDC. - 6A @ 12VDC or 24VDC. - 115/230VAC input. - 115VAC input. WayPoint5 WayPoint7V - 4A @ 12VDC

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky

More information

TB-1230 QW. User Manual Please read the instruc on carefully before use

TB-1230 QW. User Manual Please read the instruc on carefully before use TB-1230 QW User Manual Please read the instruc on carefully before use CONTENTS 1. Safety Instructions... 2 2. Technical Specifications... 3 3. How To Set The Unit... 4 3.1 Control panel... 4 3.2 Main

More information

Voltage Dip-Proofing Inverter

Voltage Dip-Proofing Inverter Voltage Dip-Proofing Inverter DPI54S / 54L Series Models 120V & 208/230 50/60Hz Contents: Introduction...3 Theory of operation...3 Specifications...5 Up-time considerations...6 Installation Guide...7 Test

More information

Ditec ION Automation for sliding gates up to 600 kg

Ditec ION Automation for sliding gates up to 600 kg INTELLIGENT SAFE VERSATILE SETTING Ditec ION Automation for sliding gates up to 600 kg EN www.doormatics.co.nz Ditec ION Ditec ION is the new range of electromechanical actuators for sliding gates designed

More information

Technology Security Low consumption

Technology Security Low consumption Control units Technology Security Low consumption TECHNOLOGICAL SOLUTIONS FOR SECURE OPERATION All the latest generation V2 control units can be configured via smartphone and tablet, with V2AppTool. The

More information

UEMC 41 Motor Operating Device

UEMC 41 Motor Operating Device Installation and operating instructions UEMC Motor Operating Device Your safety first always! All legally recognized standards, the connection conditions of the local electrical utility and the applicable

More information

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions BlueGuard FE Bluetooth Enabled Access Control MODEL BG-FE Operating Instructions CAUTION AND SAFETY INFORMATION IMPORTANT: If the equipment is used in a manner not specified in this manual, the protection

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

425D. Control Panel. Instructions. (800)

425D. Control Panel. Instructions. (800) 425D Control Panel Instructions Figure 13. Wiring detail of the 412 operator to the 425D Connecting the Operator(s) If your gate system has one operator, connect the black and white wires from your operator

More information

Thalia L QRG (See also specific motor QRG)

Thalia L QRG (See also specific motor QRG) Thalia L QRG (See also specific motor QRG) Quick reference guides are not a replacement for the supplied instructions, they are supplementary Read and understand the installer warnings in the main instruction

More information

Neptis AUTOMATIC SWING DOORS FOR PEDESTRIANS SLT-B LET-B SMT-B SLT LET SMT. English Translation of the ORIGINAL INSTRUCTIONS.

Neptis AUTOMATIC SWING DOORS FOR PEDESTRIANS SLT-B LET-B SMT-B SLT LET SMT. English Translation of the ORIGINAL INSTRUCTIONS. USER MANUAL AUTOMATIC SWING DOORS FOR PEDESTRIANS GB Neptis SLT-B LET-B SMT-B SLT LET SMT Made in Italy by English Translation of the ORIGINAL INSTRUCTIONS USER MANUAL - NEPTIS-16005_GB_Rel.1.0_04/2013

More information

E600 VX01 Installation guide

E600 VX01 Installation guide E600 VX01 Installation guide illuminfx Dimensions 2007 Viso Systems ApS, Denmark All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS LRC0 8X0A Relay Control Panel BACnet MS/TP Enabled INSTALLATI INSTRUCTIS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS!

More information

&%=579 OPERATING INSTRUCTIONS

&%=579 OPERATING INSTRUCTIONS &%=579 OPERATING INSTRUCTIONS INDEX INDEX...1 INTRODUCTION...2 Packing contents... 2 Contents of this Instruction Manual... 2 Addressee of the Instruction Manual... 2 What to read... 2 Typographic conventions...

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology Building Wash User Guide Advanced LED Technology TABLE OF CONTENTS 1. Safety Instruction 2. Technical Specification 3. Change Beam Angle 4. Main Function 5. How To Control The Unit 6. Troubleshooting 7.

More information

Number of optical axis

Number of optical axis Ultra-flat multi-beam sensor for elevators F3E Ultra-flat 9 mm shape for easy design-in in elevator constructions Highest ambient light immunity (200,000 lux) for installations with direct sunlight exposition

More information

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216

More information

PC170 Control Box USER MANUAL 24V DC GEAR MOTOR FOR RESIDENTIAL

PC170 Control Box USER MANUAL 24V DC GEAR MOTOR FOR RESIDENTIAL PC170 Control Box 24V DC GEAR MOTOR FOR RESIDENTIAL USER MANUAL INDEX 1. CONTROL BOX 2. SETTING 2.1 SW1 DIP SWITCH SETTING 2.1.1 SLOWDOWN ADJUSTMENT (DIP 1. SLOW) 2.1.2 OVER-CURRENT ADJUSTMENT (DIP 2.OVER

More information

InView Marquee Message Display

InView Marquee Message Display Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Product manual plug, sockets and coupler 16 A.- Z0251

Product manual plug, sockets and coupler 16 A.- Z0251 Product manual plug, sockets and coupler 16 A.- Z0251 INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL Operating Instructions KEYPAD Compatible WIRELESS ACCESS CONTROL Contents Technical specifications page 1 Approvals page 1 Changing the Master code page 2 Adding a User code page 3 Deleting a User code

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

EXAMPLE SYSTEM MOTORS FOR BARRIERS

EXAMPLE SYSTEM MOTORS FOR BARRIERS EXAMPLE SYSTEM 98 101 F 1 4 2 E B A 5 G C D 3 COMPONENTS ADDITIONAL ACCESSORIES 1 2 3 4 5 Motor Boom Transmitter Receiving module End support post A B C D E F G Key switch Flashing light Photocells Pillar

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

Daily use. indicating that the loud speakers

Daily use. indicating that the loud speakers BeoLab 8002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equipment to dripping or splashing and ensure that no objects

More information

909 Control Panel Instruction For Swing Gates 230VAC ONLY WITH HYDRAULIC MOTORS

909 Control Panel Instruction For Swing Gates 230VAC ONLY WITH HYDRAULIC MOTORS 909 Control Panel Instruction For Swing Gates 230VAC ONLY WITH HYDRAULIC MOTORS General safety rules WARNING: Unskilled personnel should never be allowed to assemble, repair or adjust the devices and all

More information

Capacitive Proximity Sensor E2K-X

Capacitive Proximity Sensor E2K-X Sensing Supply voltage Output 90 to 0 VAC, 0/60 z to 30 VDC 00 ma, 8, 1 mm 00 ma NPN or PNP Capacitive Proximity Sensor Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact

More information

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21- Innovation, Quality, Performance 21- imove 50SR User Guide Professional Entertainment Technology EC Declaration of Conformity We declare that our products (lighting equipments) comply with the following

More information

Universal digital indicator 4½-digit

Universal digital indicator 4½-digit SENSORS FOR FOOD AND BIOPHARMA. Product Informati PEM-UC CONTROLS Universal digital indicator ½-digit Applicati/specified usage Machine and switch cabinet cstructi Indicating and transforming of process

More information

T4HD: Installation Supplement R8.1.13

T4HD: Installation Supplement R8.1.13 THD: Installation Supplement R8.. Smartscan Incorporated 08 Eight Mile Road Livonia MI 8 Tel: (8)77-900 Fax: (8) 77-7 Web: www.smartscaninc.com Smartscan Incorporated Livonia, Michigan THD The use of this

More information

Power supply module, bus connection module

Power supply module, bus connection module s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can

More information

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual The Flomatic FDHC-100 is a high performance Digital positioner intended to control AC actuators, providing 450 points of resolution with quarter turn actuators ranging from 2 sec to 120 sec and rated for

More information

MC61BR USER/INSTALLER MANUAL. v1.0 REV. 05/2018 LAMP MOT LOCK

MC61BR USER/INSTALLER MANUAL. v1.0 REV. 05/2018 LAMP MOT LOCK MC61BR USER/INSTALLER MANUAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 LAMP MOT LOCK V+ FAP FCH PUL BL DS v1.0 REV. 05/2018 00. CONTT INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. CONNECTIONS

More information

ASI Systems ML5740A Series

ASI Systems ML5740A Series ML5740A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5740A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

LC2300 Level Controller Installation and Maintenance Instructions

LC2300 Level Controller Installation and Maintenance Instructions 4025350/5 IM-P402-72 AB Issue 5 LC2300 Level Controller Installation and Maintenance Instructions 1 General safety information LC2300 2 General product information 3 Installation >50% >100%

More information

8000 Series: Installation Supplement R2-1-12

8000 Series: Installation Supplement R2-1-12 8000 Series: Installation Supplement R2-1-12 Smartscan Incorporated, 33083 Eight Mile Road, Livonia MI 48152 Tel: (248) 477-2900 Fax: (248) 477-7453 Web: www.smartscaninc.com SMARTSCAN INCORPORATED Livonia,

More information

Nice RB600/600P RB1000/1000P RB500HS RB500HS/V1

Nice RB600/600P RB1000/1000P RB500HS RB500HS/V1 Nice RB600/600P RB1000/1000P RB500HS RB500HS/V1 For sliding gates EN - Instructions and warnings for installation and use CONTENTS GENERAL WARNINGS: SAFETY - INSTALLATION - USE 2 1 - PRODUCT DESCRIPTION

More information

ELECTRONIC CONTROL PANEL ONE THREE-PHASE MOTOR QK-CE220RLINV

ELECTRONIC CONTROL PANEL ONE THREE-PHASE MOTOR QK-CE220RLINV INSTALLER TECHNICAL MANUAL ELECTRONIC CONTROL PANEL ONE THREE-PHASE MOTOR QK-CE220RLINV Attention!! Read this manual carefully before starting the installation. N.B. - QUIKO does not accept any responsibility

More information

ELECTRONIC CONTROL PANEL FOR TWO 230VAC MOTORS TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES

ELECTRONIC CONTROL PANEL FOR TWO 230VAC MOTORS TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES ELECTRONIC CONTROL PANEL FOR TWO 230VAC MOTORS UNIK2E230 _ V2 (COMPLETE) UNIK2E230SK _ V2 (WITHOUT BOX AND TRANSFORMER) BOX IP 54 TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES WARNING! Before installing,

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

ColourChaser Touch. Installation Guide

ColourChaser Touch. Installation Guide ColourChaser Touch Installation Guide Dimensions C I S 110 29 72 Ø 4.5 56 85 I 2 3 4 100 77 ColourChaser Touch - Dimensions in mm Bracket - Dimensions in mm 2 Philips ColourChaser Touch Manual Content

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000 1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.

More information

Voltage Dip-Proofing Inverter

Voltage Dip-Proofing Inverter Voltage Dip-Proofing Inverter DPI53S / 54L Series Models 120V & 208/230 50/60Hz LEADERS IN VOLTAGE DIP-PROOFING Contents: Introduction...3 Theory of operation...3 Specifications...5 Up-time considerations...6

More information

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884

More information

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner GS400 Electronic Auto-Ranging DIN Panel Mounted Positioner Features * AC (115/230V) and DC (24V) versions available. * Accepts either current or voltage command signal and either current, voltage, or three

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

Manual Control Unit GFC 16

Manual Control Unit GFC 16 Manual Control Unit 1400003_EN/04.2017 Index 1. Main features 3 2. Tekniske data 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 5 7. Remote 7 8. Shut down

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS WARNING To reduce the risk of death, injury or property damage from fire,

More information

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA

More information

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space Edition: 2 from 05.04.2018 Supercedes the edition: 1 from 04.09.2017 EN** Features: Switch 10 ports 8 PoE ports

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

JULIET-PK. Joystick station

JULIET-PK. Joystick station Joystick station JULIET-PK Handy and compact joystick station. Juliet PK is a user-friendly, ergonomic product, whose size and shape are the result of careful analysis of the aspects linked to daily use

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. PRODUCT PRODUCT PROFILE TECHNICAL PARAMETERS 03. INSTALLATION PRODUCT

More information

ORIGINAL INSTRUCTIONS

ORIGINAL INSTRUCTIONS USER MANUAL SMP GB AUTOMATIC SWING DOORS FOR PEDESTRIANS English Translation of the ORIGINAL INSTRUCTIONS NEPTIS-SMP-16005_GB_Rel.1.0_07/2014 - CD0420GB RECOMMENDATIONS THIS INSTRUCTION MANUAL IS INTENDED

More information

Ellard Product Instructions

Ellard Product Instructions Ellard Product Instructions Motor Controller - V3D Maxi Stock Code Description Roundthorne Ind Est Floats Road Wythenshawe Manchester M23 9WB Tel: +44 (0) 161 945 4561 Fax: +44 (0) 161 945 4566 Iss: 1

More information

Series 28 Universal Sensors

Series 28 Universal Sensors Series 8 Universal Sensors Diffuse Mode with Background Suppression See pages 548-553 Features: Sharp sensing range cut-off Choice of infrared, visible red and laser light sources Sensing Range: 400 mm,

More information