E R A I GATE AUTOMATION DIVISION

Size: px
Start display at page:

Download "E R A I GATE AUTOMATION DIVISION"

Transcription

1 S E R A I GATE AUTOMATI DIVISI INSTALLATI MANUAL MERCURIO 302CF SR F KIT WITH ENCODER AND TOOTH RACK FOR SLIDING GATES (UP TO 300 kg -230Vac) CAUTI: - THE CTROL UNIT MUST BE PROGRAMMED PRIOR TO GATE OPERATI, OTHERWISE THE UNIT WILL NOT OPERATE CORRECTLY - see Page READ THIS MANUAL CAREFULLY BEFORE MAKING ANY CNECTIS, AND KEEP FOR FUTURE REFERENCE DAL 1965 Pag. 1/16

2 Thank you for choosing a SERAI ELETTRICA product, which we are confident will perform to your requirements. Please be advised that you are about to fit a system classified as a power-operated drive designed to move automatic gates and doors in commercial or residential buildings accessed by vehicles and persons, and, as such, the system must be considered potentially hazardous. By law, you are responsible for rendering this equipment as safe as is reasonably possible. Installation and maintenance of equipment of this kind must therefore be carried out by skilled, qualified and trained personnel, working in a professional manner, as provided for by DM 37/08 and subsequent amendments and supplements thereto. The law in question prohibits the construction of these types of systems by non-qualified personnel. SERAI manufacturing complies with the following legislation: Applicable directives for the CE marking: Machines: Low voltage: Electromagnetic compatibility: 2006/42/EEC 73/23/EEC + 93/68/EEC 2004/108/EEC General applicable standards: Electrical safety: Electromagnetic compatibility - emissions: Electromagnetic compatibility - immunity: IEC EN IEC EN IEC EN IEC EN Apart from the legislation mentioned above, you are also reminded to comply with the following standards during the installation phase. General applicable standards: Safety of electrical systems in non-specialised environments: Specific product standards applicable: Safety in the use of power-operated doors requirements: Safety in the use of power-operated doors testing methods: CEI 64-8 V2 UNI EN12453 UNI EN12445! SERAI products enable users to build systems which comply with these standards. This is extremely important as THE INSTALLER IS LIABLE FOR THE SYSTEM AND FOR ENSURING ITS OPERATI COMPLIES WITH LEGAL PROVISIS. This handbook must be read in full, at least once, before proceeding with the installation of the various parts of the system. The installation of the mechanical end stops for gate opening and closure is necessary for system safety purposes and therefore this operation must be performed before proceeding with the installation of the control unit. Page 2/16

3 1.1 KIT CTENTS 1. a- Motor models: MT/302 b- Encoder system c- CR/42A electronic control unit d- Release keys e- M8 grub screws for motor levelling 2. a- Base plate b- Bolts c- Nuts d- Washers 3. a- End stop sliding plates b- M6 grub screws for fastening sliding plates CHAPTER 1: GENERAL INFORMATI 4. M/16 tooth rack 5. M/10 electric key 6. Pair of P/10 photocells with plugs 7. OG/64 mini transmitter 8. Flashing light with built-in antenna RZ/20 F 9. RZ/99 L-shaped holder c b c a d b d a a e b WIRING EXAMPLE FOR KIT CTENTS CABLE FOR RX 4 x 0,5 mm² CABLE FOR LIGHT + ANTENNA 2 x 0,75 mm² + RG58 CABLE FOR TX 2 x 0,5 mm² KEY CABLE 3 x 0,5 mm² POWER SUPPLY CABLE 3 x 1,5 mm² 230 V~ Advice for wiring up in non-specialised environments. 1. Fit an omnipolar switch upstream of the system, choosing one with a gap of at least 3 mm between the contacts. Or, alternatively, use a 10A magnetothermic switch. 2. When making the connections (using any type of connector), ensure the system is disconnected from the power supply, i.e. that the main switch is in the open position ( 0 symbol). The control unit, in particular, must never be connected to the power supply either during the wiring up, or when fitting any expansion cards. 3. The following cables must be used for installation of the system: for the control unit and motor power supplies: 1.5 mm section for lengths of up to 19m, 2.5 mm section for lengths of up to 31 m, for the flashing light: 0.75 mm section for lengths of up to 3 m, 1.5 mm section for lengths of up to 19 m. - for the low voltage and current lines (e.g. For the photocells, control buttons, electromechanical key, sensitive 2 2 edges and other safety devices): 0.5 mm section for lengths of up to 50 m, 0.75 mm section for lengths of up to 100 m. 4. Wire up the earth connection in compliance with legal provisions. Page 3/16

4 2.1 BEFORE STARTING CHAPTER 2: MOTOR INSTALLATI SUPPORT RAILS MECHANICAL END STOP (CLOSURE) GROUND-ANCHORED RAIL (REINFORCED CCRETE GROUND) MECHANICAL END STOP (OPENING) Check that the gate is equipped with sturdy support rails Check that the rail is anchored securely to the ground Fit two sturdy mechanical stops at the two ends of the rail Check that the gate runs smoothly along the rail The installation of the mechanical end stops for gate opening and closure is necessary for system safety purposes and therefore this operation must be performed before proceeding with the installation of the control unit. 2.2 INSTALLING THE BASE PLATE 75 mm 35 mm 95 mm 2.2A Screw the two nuts onto the bolts, until they are positioned 35 mm from the end of the thread Fit the J bolts through the holes in the base plate Screw the other two nuts onto the J bolts without tightening 2.2B Dig a hole and place the base plate (fastened to the bolts) inside it, along with the cable carrier hose Position the base plate at the heights specified, fastening it so that it stays flat 2.2C Cast concrete to secure the unit to the ground, ensuring all the base plate parts are kept clean and the two nuts are out of the concrete completely. Wait for the concrete to harden, then remove the two nuts Page 4/16 CAUTI: If the motor is located in an area prone to flooding, the base plate must be positioned high enough to stop the water reaching the motor

5 2.3 OPENING THE MOTOR UNIT Remove the fastening screws on the side of the unit Remove the motor cover Remove the plastic casing from the motor unit 2.4 MOTOR POSITIING GRUB SCREWS NUTS WASHER 2.4 A Screw the 4 grub screws into the relevant housing Position the motor on the base plate, inserting the threaded part of the J bolts through the slots in the base Level the motor by adjusting the grub screws Fit the washers onto the bolts and screw on the 2 nuts without tightening them completely. These bolts must not be secured until the tooth rack is in its final position 2.4 B Cut small holes in the rubber seals, so that they grip each of the cables properly. If this operation is not carried out and insects get inside the unit, a short circuit may occur, causing irreparable damage to the ECU. 2.5 RELEASING THE MOTOR Fit the release key into the lock on the front panel of the motor unit and turn it anticlockwise by a half turn Push the release flap hard downwards until the release mechanism is triggered 1/2 Page 5/16

6 2.6 TOOTH RACK INSTALLATI 2.6 A CAUTI: check that the pinion engages with the tooth rack along the entire width of the tooth PINI NO TOOTH RACK PINI YES TOOTH RACK INSTALLATI OF RACK M/16 (RECOMMENDED FOR ITS QUIETNESS) IN NYL PA66 LOADED WITH GLASS FIBRE. THE GLASS FIBRE IS USED AS REINFORCEMENT AND INCREASES STRENGTH APPROX. CLEARANCE 2 mm 2.6 B Fix the 340 mm long rack bars between them until the full "gate + motor + slides" path is covered. Fix using M6 selftapping screws -not supplied- Upon completion of operation, vertically adjust, through the slot holes on the rack, the distance between the pinion and the same rack so that, by manually sliding the gate, a constant clearance of 2 mm is maintained. Page 6/16

7 2.7 INSTALLATI OF THE END STOP SLIDING PLATES 2.7A POSITIING 5 cm MECHANICAL END STOP (CLOSURE) CLICK! MAX 35 mm MIN 25 mm MECHANICAL END STOP (OPENING) CAUTI: For safety reasons, an end stop must be fitted for both the closure and opening movements MOTOR Slide the gate manually until it is approximately 5 cm away from the mechanical end stop Position the sliding plate so that it controls the microswitch actuator spring; you should hear a click as the microswitch flips when the sliding plate passes it CAUTI: - To guarantee correct limit switch operation, ensure there is a distance of 30 mm (tolerance: ± 5 mm) between the side of the motor and the sliding plate. A gap of over 35 mm may cause the gate to jam open or closed. A gap of under 25 mm may cause breakage of the limit switch control spring. - The end stop sliding plates must be set (taking into account inertia and changes in temperature) so that the gate never ends up resting on the mechanical end stops during opening and closure. If this occurs, the FLAP COULD GET BROKEN during the release operation. Because of seasonal temperature differences, we recommend you check this in both summer and winter. 2.7B FASTENING CUT BEND TOOTH RACK Once the correct position has been found, fasten the sliding plate to the tooth rack using the two M6 grub screws supplied If need be, it is possible to shorten the slide plates cutting and blending the front side Repeat the operation during opening 2.8 DEFINITIVE MOTOR FASTENING TIGHTEN FULLY 2.8 A Tighten the nuts on the J bolts fully Place the lower plastic casing and the motor cover back in position, fastening the latter with the two side screws 2.8 C Open or close the gate a few cm by hand until the stop pinion locks 2.8 B Lock the motor manually by closing the release flap and removing the key from the lock cylinder Page 7/16

8 CHAPTER 3: CR/42A ELECTRIC CTROL UNIT 3.1 CR/42A WIRING DIAGRAM TRANSMITTER PHOTOCELL (FOR CLOSURE OR OPENING) RECEIVER C1 NC OPEN/CLOSE -START- NO PEDESTRIAN NO STOP NC OPENING LIMIT SWITCH COMM OPEN CLOSE NC CLOSURE LIMIT SWITCH SENSITIVE EDGE NC NC INDICATOR LIGHTS nd 2 C START PED STOP FOTO FCA FCC COSTA + REG - PAUSE WORK DL10 PROG ENCODER DL11 SW1 SW DL12 SOG/4A F2 DISCNECT THE POWER SUPPLY BEFORE WORKING THE WIRING COURTESY LIGHT 230V~ FLASHING LIGHT 230V~ V~ ±10% F 2 50/60Hz N 1 F1 GND C1 Starting capacitor for models MT/302 ANTENNA TERMINALS Page 8/16 CNECTIS POWER SUPPLY FLASHING LIGHT COURTESY LIGHT MOTOR POWER SUPPLY PHOTOCELLS INPUT COMM SENSITIVE EDGE LIMIT SWITCH (CLOSURE) LIMIT SWITCH (OPENING) PHOTOCELL (FOR CLOSURE OR OPENING) STOP CTROL PEDESTRIAN CTROL OPEN/CLOSE CTROL -START- BUILT-IN RECEIVER ANTENNA DESCRIPTI Card power supply input 230V~ ±10% 50/60 Hz Flashing light power supply output -max 50W- SERAI RZ/2 Courtesy light output -max 100W- active for 90 seconds from STOP Motor power supply output (8 = Common 6 = Opening/Closure) 7 = Opening/Closure) Power supply output 24Vdc (9=+, 10=-) max 500mA for photocells CAUTI: always respect the polarity Input common terminals Sensitive edge input (NC contact): inverts movement by 10cm. Closure limit switch (NC contact when gate is in an intermediate position) Opening limit switch (NC contact when gate is in an intermediate position) With dip1 SW2 OFF: input for photocell active during closure only (NC contact). With dip1 SW2 : input for photocell active during both closure and opening (NC contact). Stop control input (NC contact). When pressed, this control locks out motor operation; if pressed during the gate open pause time, it overrides the automatic reclosure Pedestrian control input (NO contact). When pressed, this control opens the gate by approx. 1 metre N.B. This function can be modified as described in "modify controls". Open/close control input (NO contact) - this controls gate opening and closure in the step-step mode N.B. This function can be modified as described in "modify controls". Input for antenna connection for built-in receiver (21=ANTENNA, 22=GND/braid) nd 2 C INDICATOR LIGHT Connector for wiring for MR/08 relay module for gate open indicator light nd and 2 capacitor SOG/4A Connector for any SOG/4A receiver cards ENCODER Connector for encoder wiring (If featured) Sw1 Microswitches for control unit setting Sw2 Microswitches for control unit setting PROG Button to enter programming mode WORK Work programming button PAUSE Button for gate open pause Programming REG Trimmer for motor force adjustment FUSES: F1 = 5A 250V~ power supply protection 230V F2 = T1,6A 250V~ low voltage protection

9 3.2 EARTH CNECTI POWER SUPPLY CABLE 230 V~ YELLOW/GREEN CABLE MOTOR CNECTI TERMINAL 3.3 MOTOR CNECTIS The connections differ depending on whether the motor (viewed from inside the gate) is positioned on the right (factory setup) or on the left. MOTOR THE RIGHT (FACTORY SETUP) MOTOR THE LEFT CLOSE OPEN COMM CR/42A BROWN BLACK BLUE To connect the motor on the left-hand side of the gate, swap the following connections: 6 with 7 13 with LED SIGNALS LED FUNCTI OFF START Open/Close button Open/Close button pressed Open/Close button in normal status PED PEDESTRIAN button Pedestrian button pressed Pedestrian button in normal status STOP STOP button Stop button in normal status Stop button pressed FOTO FCA FCC Photocell Opening limit switch Closure limit switch Photocell clear Gate moving or in intermediate position (NC contact) Gate moving or in intermediate position (NC contact) Photocell obscured (obstacle present) Gate completely open (NO contact) Gate completely closed (NO contact) COSTA Sensitive edge Sensitive edge in normal status Sensitive edge pressed DL10 Programming/Test - Flashing light to show programming mode has been accessed - High frequency flashing light to indicate faults encountered during the motor control test DL11 Motor control Brightness varies depending on the motor control voltage DL12 Encoder During gate movement, indicates encoder pulse reception Page 9/16

10 3.5 SETTINGS OF EACH MICROSWITCH CAUTI: If the microswitch programming is modified, the new settings are rendered Active by switching the control unit off then on again. OPERATI SETTING DESCRIPTI OF OPERATI PHOTOCELL OPERATI MODE SW2 SW2 Input for photocell active during closure only: if obscured during closure, the gate stops and then opens again. If obscured during opening, the photocell does not respond. Input for photocell active during both closure and opening: if the photocell is obscured during opening, the gate stops moving, but starts again as soon as the photocell is clear; if the photocell is obscured during closure, the gate will stop moving, and then start opening again. ENABLE/DISABLE IMMEDIATE CLOSURE FUNCTI IN THE EVENT OF PASSAGE ACROSS THE PHOTOCELL SW2 SW2 Immediate closure function disabled Immediate closure function enabled IMPACT WITH OBSTACLE SW1 SW1 Force limitation activated: in the event of an impact with an obstacle, whether during opening or closure, an encoder system detects the impact, stops the gate and then reverses it by 10cm see Page 11. Force limitation deactivated: impact with an obstacle is not detected and the motor goes on driving the gate. CAUTI: with the force limitation feature deactivated, other safety devices must be adopted (e.g. sensitive edge), which must be compliant with regulations in force. ENABLE/DISABLE FLASHING LIGHT PRE-FLASHING SW1 Pre-flashing disabled: the flashing light switches on at the same time as the gate starts opening SW1 Pre-flashing enabled: the flashing light switches on 3 seconds prior to the gate opening. ENABLE/DISABLE STEP-STEP OPERATI MODE SW1 SW1 Step-step function enabled During opening: if an open/close command is sent, gate motion stops; if the command is sent again, gate closure is activated. During closure: if an open/close command is sent, gate motion stops; if the command is sent again, gate opening is activated. During open gate pause: an open/close command overrides the pause times, making the gate close immediately. Step-step function disabled During opening: if an OPEN/CLOSE command is sent, it is ignored and the gate goes on opening. During closure: if an OPEN/CLOSE command is sent, gate motion stops for a few seconds and then the gate starts opening again. During open gate pause: overrides the pause time, making the gate close immediately. DO NOT USE SW1 Leave on OFF position Page 10/16

11 ND 3.6 GATE OPEN INDICATOR LIGHT AND 2 STARTING RELAY (RELAY MODULE MR/08) ND The INDICATOR LIGHT 2 C connector located between the two terminal boards serves to connect relay module MR/08 SR 24.08, which allows: 1- an optical signalling device to be located inside the building. In more detail, the NO/C terminals (clean relay contact 3A 250Vac) can be used to provide the following signals: Light lit permanently: Light flashing slowly: Light flashing fast: gate is open and stationary gate opening manoeuvre gate closure manoeuvre 2- a second starting capacitor to be connected, which remains active for approx. 2 s every time the motor starts. F2 F1 VOLTAGE FREE RELAY CTACT -NO 3A 250Vac- FOR OPTICAL SIGNALLING VOLTAGE FREE RELAY CTACT -NO- ND FOR 2 STARTING CAPACITOR SPIA 2 CD MR/08 MODULE 3.7 OBSTACLE IMPACT CTROL - MOTOR FORCE ADJUSTMENT - SENSITIVE EDGE With the SW1 microswitch 1 in the OFF status, obstacle impact is detected (during both the opening and closure manoeuvres) by the encoder system which stops the gate moving and then reverses it by approx. 10 cm. This control is switched off with the SW1 microswitch 1 in the status; in this case, other safety systems compliant with regulations in force (e.g. sensitive edges) must be adopted. The impact force is adjusted using the REG potentiometer during the programming phase and adjustments must be performed in compliance with the regulations in force. F2 CAUTI: The considerable differences in temperature between summer and winter can cause differing rates of expansion in all materials, including those used for manufacturing our motors. That is why we recommend you check the impact force setting at the start of winter and summer. F1 The sensitive edge can be fitted both on the fixed parts as well as on the gate itself (in front and back of the gate) and can be connected to the input 12 or in series to the stop or in series to the photocells, according to the protection requirements deriving from the laws in force. THE INSTALLER IS LIABLE FOR THE SYSTEM AND FOR ENSURING ITS OPERATI COMPLIES WITH LEGAL PROVISIS. 3.8 CR/42A CTROL UNIT TECHNICAL SPECIFICATIS Power supply : 230Vac ±10% 50/60Hz Motor power supply : 1 single-phase motor, 230Vac, 400W Accessories power supply : 24Vdc, 500mA Flashing light power supply : 230Vac, max 50W Courtesy light power supply : 230Vac, max 100W Courtesy light : 90 s permanently lit from when the gate stops Starting time : 2 s permanently lit Motor work time maximum safe level- : 300s Pause time setting : from 0 to 120s Operating temperature : -20 C + 60 C Dimensions and weight : 112x151x50mm, 555g Page 11/16

12 3.9 CR/42A CTROL UNIT PROGRAMMING Before proceeding with the programming, check that the system is equipped with all the electrical and safety devices (buttons, photocells, flashing lights, etc.) and that they are all connected. Ensure they all operate correctly, i.e.: All the indicator LEDs for the NC inputs (stop, photocell, limit switch, sensitive edge) are lit; All the indicator LEDs for the NO inputs (open/close, pedestrian) are off. In the event of faults, ascertain and remove the cause. CAUTI: ANY UNUSED NORMALLY CLOSED (NC) INPUTS MUST BE JUMPERED. The next section deals with the CR/42A control unit programming. It is important to follow the programming step by step; in the event of errors during this stage, a new programming session must be performed, in which case the new data will replace the previous data. To quit an incorrect programming session, switch the control unit off then on again PROGRAMMING THE WORK TIMES AND IMPACT FORCE SETTING MANUALLY The deceleration point is set by the installer and can be cut out With the control unit powered, release the gate, open it approx. 2 metres, then relock it. Press the PROG, button once; the DL10 LED will start flashing, indicating that the control unit has entered the programming phase. Press the WORK button once to start the closure manoeuvre. The sliding gate will begin the closure manoeuvre with a starting thrust and will then decelerate and continue at a slow pace. During slowing down, adjust the REG trimmer to set the force that will be applied during deceleration (in the event of impact with an obstacle). Once the closure manoeuvre is complete and the FCC (closure limit switch) LED is off, set the REG trimmer back at half stroke. Press the LAVORO (Operation) button once: the gate will start opening. During the opening manoeuvre, adjust the REG trimmer again to set the force that will be applied during deceleration (in the event of impact with an obstacle). Before the gate completes the opening manoeuvre, press the LAVORO (Operation) button (we recommend doing this when it is 50 cm away from the end stop). This sets the desired deceleration start point, and the gate will start the deceleration phase. N.B. If you wish to deactivate deceleration during normal operation cycles, skip this step. As soon as the gate has completed the opening manoeuvre, the work cycle is acquired, as is the deceleration point, if set. After a few seconds, the closure manoeuvre starts, and the programmed deceleration is applied. When the gate reaches the closure limit switches (FCC LED off), the control unit automatically quits the programming phase and switches to standard operation mode. Page 12/16 CAUTI: If one or more parameters are altered, programming must be repeated from the beginning GATE OPEN PAUSE TIME PROGRAMMING ACTIVATING AUTOMATIC RECLOSURE (max time settable: 120 s) With the control unit powered and the gate closed (closure limit switch FCC - LED off), press the PROG, button once; the DL10 LED will start flashing, indicating that the card has entered the Programming phase. Press the PAUSA (Pause) button once, keeping it pressed until the flashing light comes on; the control unit will start the gate open pause count, which is indicated by the light flashing intermittently. Once the desired time has lapsed, press the PAUSA (Pause) button again; the control unit will automatically store the amount of time between the two times the PAUSA (Pause) button was pressed. It then quits the programming phase and switches to standard operation mode. If the PAUSA (Pause) button is not pressed a second time within 120 s, the control unit quits the programming, memorising the maximum time as 120 s. DEACTIVATING AUTOMATIC RECLOSURE With the control unit powered and the gate closed (closure limit switch FCC - LED off), press the PROG button once; the DL10 LED will start flashing, indicating that the card has entered the programming phase. Press the PAUSA (Pause) button and keep it pressed until the DL10 LED switches off. The control unit quits the programming phase and switches to standard operation mode. This operation deactivates the automatic reclosure function. CTROLS MODIFICATI It is possible to modify the functioning of the 18 and 19 inputs in this way: - Input 19 functions as "START": with control unit off, press and hold keys "PROGR" and "WORK" simultaneously and apply power supply. - Input 19 functions as "CLOSE only": with control unit off, press and hold keys "PROGR" and "PAUSE" simultaneously and apply power supply. - Input 18 functions as "PEDESTRIAN": with control unit off, press and hold keys "WORK" and "PAUSE" simultaneously and apply power supply. - Input 18 functions as "OPEN only": with control unit off, press and hold keys "PAUSE" and "WORK" and "PROGR" simultaneously and apply power supply.

13 CHAPTER 4: MINI TRANSMITTER CODE LEARNING The electronic card incorporates a MHz 2-channel radio receiver which allows remote gate control via either the OG/02 and OG/04 series microswitch-operated mini transmitters or the self-learning mini transmitters from the following series: OG/62, OG/64, OG/28, OG/48, OG/52, OG/54, OG/82/1 and OG/84. Both channels are used solely for gate control; more specifically, channel 1 of the radio receiver serves for the open/close function, while channel 2 is used for the pedestrian function.!! CAUTI: - a mini transmitter must be programmed before it is used. - the maximum number of codes that can be stored is 32 for the open/close control + 32 for the pedestrian control (no other combinations, e.g. 40 open/close + 24 pedestrian etc, are possible). Let's have a look at two examples of storable codes: - example A: 32 self-learning mini transmitters from the following series: OG/62, OG/64, OG/28, OG/48, OG/52, OG/54, OG/82/1 and OG/84 as the open/close control (e.g. left-hand button) + 32 self-learning mini transmitters from the following series: OG/62, OG/64, OG/28, OG/48, OG/52, OG/54, OG/82/1 and OG/84 as the pedestrian control (e.g. right-hand button) - example B: 31 self-learning mini transmitters from the following series: OG/62, OG/64, OG/28, OG/48, OG/52, OG/54, OG/82/1 and OG/84 as the open/close control (e.g. left-hand button) + 1 OG/02 or OG/04 series microswitch-operated mini transmitter as the open/close control (there is no need to store the other OG/02 and OG/04 transmitters, simply set the microswitches in the same sequence as the one already stored) + 31 selflearning mini transmitters from the following series: OG/62, OG/64, OG/28, OG/48, OG/52, OG/54, OG/82/1 and OG/84 as the pedestrian control (e.g. the right-hand button) + 1 OG/02 or OG/04 microswitch-operated mini transmitter as pedestrian control (there is no need to store the other OG/02 and OG/04 transmitters, simply set the microswitches in the same sequence as the one already stored) CAUTI: before proceeding with the mini transmitter programming or clearing phase, disconnect the antenna to prevent the receiver from acquiring other signals during these phases which could impair automation operation. Reconnect the antenna once the procedures are complete. MICROSWITCH CFIGURATI (FOR OG/02 AND OG/04 MINI TRANSMITTERS LY) These instructions only apply if the OG/02 and OG/04 series microswitchoperated mini transmitters are fitted. Before performing the code learning procedure on the receiver, the factory-set configuration of the microswitches must be modified to prevent unwanted commands ! MODIFYING THE FACTORY-SET CFIGURATI TO PREVENT UNWANTED COMMANDS 4.1 MINI TRANSMITTER PROGRAMMING PROCEDURE OPEN/CLOSE CODE LEARNING - With the control unit powered and the gate closed, press the PROG key once to enter the programming phase. The DL10 LED starts flashing to indicate that the control unit is in the programming mode. - Press the button on the mini transmitter (the left-hand one, for example) which you wish to serve as the open/close control, and keep it pressed until the DL10 LED switches off. The control unit stores the radio code received and automatically quits the programming phase, switching to the standard operation mode. - Repeat the procedure if several mini transmitters need to be stored. PEDESTRIAN CODE LEARNING - With the control unit powered and the gate closed, press and hold down the PROG key to enter the programming phase. The DL10 LED starts flashing to indicate that the control unit is in the programming mode. - Keeping PROG pressed, push the button on the mini transmitter (the right-hand one, for example) which you wish to serve as the pedestrian control, and keep the two buttons pressed until the DL10 LED switches off. The control unit stores the radio code received and automatically quits the programming phase, switching to the standard operation mode. - Repeat the procedure if several mini transmitters have to be stored. 4.2 CLEARING OF STORED CODES All the radio codes stored in the memory can be cleared by pressing the PROG and PAUSA keys AT THE SAME TIME, and keeping them pressed until the DL10 LED switches off (approx. 10 s) without sending any radio codes during this time. This operation clears all the codes associated to both the open/close and the pedestrian control. Page 13/16

14 EXPANDING THE NUMBER OF MINI TRANSMITTERS If the 32 mini transmitters storable in the built-in receiver are not sufficient, they can be increased by fitting the SOG/4A receiver (which increases the number of mini transmitters up to 40), possibly with the addition of the SOG/2A expansion card (which increases the number of mini transmitters up to 834). After fitting the SOG/4A receiver, all the codes stored in the built-in receiver must be cleared and all the mini transmitters on the new SOG/4A receiver reprogrammed (see specific instructions). The antenna must be moved from the terminals on the control unit to the terminals on the SOG/4A DISCNECT THE POWER SUPPLY BEFORE WORKING THE WIRING FIT THE SOG/4A RECEIVER ND 2 CHANNEL OUTPUT: AUXILIARY CTROL NC NO NO C NC Channel 2 output (relay contact) Max. applicable voltage = 24Vac/dc Corrente Max applicabile= 1A F2 ST 1 CHANNEL OUTPUT: CTROL UNIT START CTROL PEDESTRIAN CTROL TERMINALS OTHER F1 5.1 TECHNICAL SPECIFICATIS 5.2 INSTALLATI POSITI 90 mm 70 mm 40 mm ANTENNA OTHER AUTOMATIS CHAPTER 5: P/10 PHOTOCELLS TX RX ELECTRIC LOCKS LIGHTS Power supply V~ ±10% Relay output A 24 V~ Range m outdoors - 20 m indoors - TX absorption ma a 24 V-; 67 ma a 24 V-; RX absorption ma a 24 V-; 25 ma a 24 V-; Temperature C Dimensions and weight x 40 x 90 mm 120 g RECEIVER NO h MIN h l MIN= 40 cm MAX = 10 m l MAX h MIN 5.2 A The receiver must not be exposed to direct sunlight; recommended height from ground = 50 cm 5.2 C If two pairs of photocells are installed, position the transmitters on opposite sides 5.3 INSTALLATI TRANSMITTER RX RX RECEIVER + - NO TX TX TX RX NO OK RX TX OK Page 14/16 CABLE ROUTING HOLE POWER SUPPLY LED RELAY OUTPUT: THE CTACT POSITI REFERS TO WHEN THE RECEIVER IS ENERGIZED RECEIVER TRANSMITTER 5.3 A Open the photocell by unscrewing the front screw completely and pulling the tab underneath the appliance 5.3 B Open up the cable routing hole on the base of the housing by either boring it or forcing it CAUTI To prevent tiny insects getting inside, the cable routing hole must be exactly the right size for the cable, and no bigger. 5.3 C Using the drilling template supplied, make the holes required in the fastening surface. Hole sizes: - Ø 6 mm for wall mounting, in which case use the masonry plugs supplied - Ø 3.5 mm for mounting on a metal support, in which case use the self-threading screws supplied Fasten the base of the photocells to the surface 5.3 D Wire up and seal the photocell CAUTI always respect the polarity for the receiver power supply connection 5.4 E Check photocell alignment using the red LED on the receiver: - LED on: photocell not aligned or obstructed - LED off: photocell aligned

15 ! WHEN REPLACING LIGHT BULBS, ALWAYS USE BULBS WITH MIN. SPECIFICATIS: 240 V~ MIN, 25W, E14 CHAPTER 6: RZ/20 F FLASHING LIGHT CNECTIS OK NO Rg58 ANTENNA 230 Vac! 2 x 0,75 mm² POWER SUPPLY CS/07 SR12.07 OPTIAL CABLE RZ/99 SR L-SHAPED HOLDER CAUTI: WE RECOMMEND THAT THE POWER SUPPLY CABLE BE POSITIED INSIDE A CDUIT WHICH IS NOT ACCESSIBLE BY THE USER. IF, THE OTHER HAND, THERE ARE ANY ACCESSIBLE PARTS, THESE MUST BE DOUBLY INSULATED FOR THE USER'S PROTECTI; A CABLE CLAMP MUST ALSO BE USED TO PREVENT THE SAID CABLE FROM BEING TUGGED OR RIPPED. CHAPTER 7: GEARMOTOR SPECIFICATIS MT/302 Motor type Max gate weight Power supply Absorbed current Absorbed power Traction and thrust force Motor power adjustment Gate speed Motor thermal protection Gear ratio Protection class Operating temperature Dimensions and weight Irreversible 300 Kg 230 V~ 10% 50/60 Hz 1,5 A 140 W 530 N Adjusted via the power supply voltage 10 m/min C 1:28 IP44-20 C +60 C 216 X 272 X 248 mm - 9,6Kg 216 mm 248 mm 82 mm 272 mm CHAPTER 8 POWER CUT - manual gate release - In the event of a power cut, the gate can be moved manually by releasing the motor as shown above. CAUTI: if the gate is in an intermediate position (one of the limit switches has not been pressed) when power is restored, the next time the open command is sent, the manoeuvre will be performed in deceleration mode for a maximum time of 300 s. If, during that time, the limit switch is still not reached, the subsequent closure manoeuvre will be performed normally. To prevent this, the gate must be moved during the power cut to either the fully open or the fully closed position (so that one of the limit switches is pressed). 8.1 A Fit the release key into the lock on the front panel of the motor unit and turn it anticlockwise by a half turn. Push the release flap hard downwards until the release mechanism is triggered. The gate can now be moved by hand 1/2 CAUTI: The gate must not be resting on the mechanical end stops, otherwise the force required to perform the release manoeuvre would break the flap 8.1 B To relock the gate, lift the release flap and remove the key from the lock cylinder. Open or close the gate a few cm by hand until the stop pinion locks, ensuring the limit switch has been pressed. Page 15/16

16 PROBLEM CAUSE SOLUTI The gearmotor is not working The gate does not complete its travel The gate does not move or the motor slips The gate has difficulty starting The gate is jammed against the mechanical end stop The remote control range is reduced No power Fuse fault Motor thermal protection cutting in Obstacle impact control cutting in Unsuitable limit switch setting Unsuitable gearmotor position Power cut during operation Motor force setting not optimal Capacitors worn out Unsuitable limit switch sliding plate setting Unsuitable antenna connection External antenna required SOG/4A receiver in use CHAPTER 9: TROUBLESHOOTING GUIDE Check the motor power supply input terminals to see if they are live. Check that the power supply cable is not cut or broken (cable replacement must be carried out by an authorised technician). Replace the fuse. or at the Authorised Service Centres. Carriage costs shall be borne by the Customer. MADE IN ITALY VIA ENRICO FERMI, LEGNARO - PADOVA ELETTRICA PADOVA I I T A L I A Leave the motor stationary for at least 5 minutes and then check operation again. Release the gate manually and check that there are no obstacles. If obstacles are found, remove them. Repeat the work times and impact force setting programming procedure, setting a greater force. N.B. The impact control can be switched off by positioning the SW1 microswitch 1 to ; in this case, other safety systems compliant with regulations in force (e.g. sensitive edges) must be adopted. This is extremely important as THE INSTALLER IS LIABLE FOR THE SYSTEM AND FOR ENSURING ITS OPERATI COMPLIES WITH LEGAL PROVISIS. Check and adjust the position of the end stop sliding plates and that they activate the control spring. Check that the distance between the end stop sliding plate and the front, outgoing trim of the spring is between 25 and 35 mm. The first opening manoeuvre takes place during deceleration (if the gate is in an intermediate position) and can take up to 300 s; if it does not occur within this time, the gate must be moved to the fully open or fully closed position by hand (see chapter 8). Repeat the work times and impact force setting programming. Measure the capacitances of the capacitors and if necessary, replace them. Remove the lower casing from the motor. Unscrew the nuts fastening the base plate bolts. Remove the motor from its position by releasing the pinion from the tooth rack. By hand, move the gate right away from the mechanical end stop. Release the motor manually. Reposition the motor on the base plate. Set the end stop sliding plates properly. Replace the lower casing and secure the motor. If necessary, repeat the work times and impact force setting programming. Check that the antenna is connected correctly to terminals 21 and 22. To permit maximum reception distance, replace the internal antenna on the flashing light with an external one (SERAI OG/50 -SR 25.50). Replace the built-in receiver with the SOG/4A card. WEEE DIRECTIVE 2002/96/EC This appliance was manufactured after 13/08/2005. To protect the environment: when the equipment is no longer needed, take it to a special WEEE (Waste Electric and Electronic Equipment) collection centre. Do not dispose of it with normal household waste. CE CFORMITY DECLARATI SERAI spa declares that the product MERCURIO/302CF has been desifned and manufactured according to the above mentioned directives and standards TERMS OF GUARANTEE The company reserves the right to make modifications to the equipment without prior notice thereof. SERAI products are covered by a standard guarantee with a term of 24 months. Coverage starts on the date on which the tax document constituting proof of purchase is issued and guarantee services shall be provided on the company's premises at Legnaro - PD - PHE FAX export@serai.com WEB MERCURIO/302CF I E A4Vf/r -IS MERC302CF-E

E R A I INSTALLATION MANUAL. Gate Opener Department

E R A I INSTALLATION MANUAL. Gate Opener Department S E R A I Gate Opener Department INSTALLATI MANUAL MERCURIO 524A F SR 24.85/24A F KIT WITH ENCODER FOR SLIDING GATES UP TO 500 kg -24Vdc MERCURIO 524A H SR 24.84/24A MOTOR WITH CTROL UNIT FOR SLIDING GATES

More information

E R A I GATE AUTOMATION DIVISION

E R A I GATE AUTOMATION DIVISION S E R A I GATE AUTOMATI DIVISI INSTALLATI MANUAL KIT/30 F - SR 03.32 F - KIT WITH 2 MOTORS FOR SWING GATES UP TO 3.0 + 3.0 METERS AND 300 kg PER LEAF - 230 Vac KIT/39 F - SR 02.39 F - KIT WITH 2 MOTORS

More information

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual Q45 230V ac Control panel for electric rolling shutters 230Vac Built-in radio receiver 433Mhz Adjustable pause time for automatic closing function

More information

STYLO STYLO ME - STYLO RME English EN

STYLO STYLO ME - STYLO RME English EN 119DV11EN EXTERNAL OPERATOR FOR SWING GATES Installation manual STYLO STYLO ME - STYLO RME English EN EN CAUTION! important personal safety instructions: READ CAREFULLY! Foreword This product should only

More information

Ditec ION Automation for sliding gates up to 600 kg

Ditec ION Automation for sliding gates up to 600 kg INTELLIGENT SAFE VERSATILE SETTING Ditec ION Automation for sliding gates up to 600 kg EN www.doormatics.co.nz Ditec ION Ditec ION is the new range of electromechanical actuators for sliding gates designed

More information

Control board for electromechanical gearmotors HERMES

Control board for electromechanical gearmotors HERMES Control board for electromechanical gearmotors HERMES 1 Attention! The present user manual is designed for personnel skilled in installation, not for the final user; the electrician is then due to inform

More information

SAFETY INFORMATION. Precautions to be observed for the choice and installation of the device

SAFETY INFORMATION. Precautions to be observed for the choice and installation of the device SG-BWS-T4-MT SERIES Safety control unit with double muting SAFETY INFORMATI QUICK GUIDE The following points must be observed for a correct and safe use of the safety light curtains of the SG-BWS-T4-MT

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL Operating Instructions KEYPAD Compatible WIRELESS ACCESS CONTROL Contents Technical specifications page 1 Approvals page 1 Changing the Master code page 2 Adding a User code page 3 Deleting a User code

More information

8000 Sports Scoreboards

8000 Sports Scoreboards 8000 Sports Scoreboards Installation manual www.bodet-sport.com Bodet Sport 1 rue du Général de Gaulle 49340 Trémentines I FRANCE Tel: +33 (0) 2 41 71 72 00 Fax: +33 (0) 2 41 71 72 01 Ref: 608080 F Ensure

More information

CB17 CONTROL SYSTEM USER MANUAL

CB17 CONTROL SYSTEM USER MANUAL CB1 CTROL SYSTEM USER MANUAL INDEX 1. CTROL BOX 2. CB1 CTORL PANEL LAYOUT AND WIRE CNECTI INDICATI 3. SYSTEM SET UP PROCEDURE 3.1 TRANSMITTER MEMORIZINGAND ERASING PROCESS 3.2 SYSTEM LEARNING PROCESS 3.3

More information

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK TARGHA 200 A/200N AGATA C200 UK Installation Manual AGATAKIT C 200 UK 24806770/28-05-2013 AGK200C03UK HPC/1 AGATA C200 UK AG2K200C03UK HPC/2 HA/200 HBP AG3K200C03UK HPC/3 A/200N AGK200C03HNA HPC/1+HNA

More information

CENTRALE DI COMANDO ANALOGICA

CENTRALE DI COMANDO ANALOGICA V2 S.p.A. Corso Principi di Piemonte, 65/67 12035 RACCONIGI (CN) ITALY tel. +39.0172.812411 - fax +39.0172.84050 info@gatestore.co.uk www.remotecontrolgates.co.uk Easy3-4 IL n. 207 EDIZ. 20/10/2010 I GB

More information

TCNM-ACBB1 Installation Manual

TCNM-ACBB1 Installation Manual The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is

More information

Q80A. 230V ac. CONTROL PANEL FOR DOUBLE/SINGLE SWING GATES Instructions Manual. Multi-function control panel for double/single swing gate - 230Vac

Q80A. 230V ac. CONTROL PANEL FOR DOUBLE/SINGLE SWING GATES Instructions Manual. Multi-function control panel for double/single swing gate - 230Vac CONTROL PANEL FOR DOUBLE/SINGLE SWING GATES Instructions Manual Q80A 230V ac Multi-function control panel for double/single swing gate - 230Vac Programming display Electronic adjustment of each motor s

More information

MOOV-B400-24V ATTUATORE ELETTROMECCANICO IRREVERSIBILE 24V PER CANCELLI A BATTENTE. ISTRUZIONI D'USO E INSTALLAZIONE

MOOV-B400-24V ATTUATORE ELETTROMECCANICO IRREVERSIBILE 24V PER CANCELLI A BATTENTE. ISTRUZIONI D'USO E INSTALLAZIONE IL n. 390 EDIZ. 02/07/2013 ITALIANO MOOV-B400-24V I GB F E P ATTUATORE ELETTROMECCANICO IRREVERSIBILE 24V PER CANCELLI A BATTENTE. ISTRUZIONI D'USO E INSTALLAZIONE 24V IRREVERSIBLE ELECTROMECHANICAL ACTUATOR

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check

More information

ASI Systems ML5740A Series

ASI Systems ML5740A Series ML5740A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5740A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

AUTOMATION FOR SWING GATES ATI SERIES INSTALLATION MANUAL A 3024 N A 5024 N

AUTOMATION FOR SWING GATES ATI SERIES INSTALLATION MANUAL A 3024 N A 5024 N AUTOMATION FOR SWING GATES ATI SERIES INSTALLATION MANUAL A 3024 N A 5024 N IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION

More information

EWCH 485 Electronic Pulse Counter

EWCH 485 Electronic Pulse Counter Electronic Pulse Counter Technical Data Sheet INSTRUMENT DESCRIPTION GENERAL DESCRIPTION is a programmable microprocessor based counter with 1or 2 outputs. The instrument offers the possibility to program:

More information

MC61BR USER/INSTALLER MANUAL. v1.0 REV. 05/2018 LAMP MOT LOCK

MC61BR USER/INSTALLER MANUAL. v1.0 REV. 05/2018 LAMP MOT LOCK MC61BR USER/INSTALLER MANUAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 LAMP MOT LOCK V+ FAP FCH PUL BL DS v1.0 REV. 05/2018 00. CONTT INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. CONNECTIONS

More information

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-MON UNIVERSAL SAFETY PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

Control Box Setup - PRSalpha

Control Box Setup - PRSalpha 888-680-4466 ShopBotTools.com Control Box Setup - PRSalpha Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Parts List: Hooking Up a PRSalpha Gantry Tool Powering the

More information

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions DIN RAIL ELECTRONIC FAN SPEED Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

ASI Systems ML5720A Series

ASI Systems ML5720A Series ML5720A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5720A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

EXAMPLE SYSTEM MOTORS FOR BARRIERS

EXAMPLE SYSTEM MOTORS FOR BARRIERS EXAMPLE SYSTEM 98 101 F 1 4 2 E B A 5 G C D 3 COMPONENTS ADDITIONAL ACCESSORIES 1 2 3 4 5 Motor Boom Transmitter Receiving module End support post A B C D E F G Key switch Flashing light Photocells Pillar

More information

Wireless 7 Day Programmable Room Thermostat

Wireless 7 Day Programmable Room Thermostat Wireless 7 Day Programmable Room Thermostat Model: TRT037N Installation & Operating Instructions 1. General Information These instructions should be read carefully and retained for further reference and

More information

INSTALLATION MANUAL. Gateway option box EKLONPG EKBNPG

INSTALLATION MANUAL. Gateway option box EKLONPG EKBNPG INSTALLATI MANUAL CTENTS Page FUNCTI Accessories... Function... Name and function of parts... Selecting the installation site... Mechanical installation... Electric wiring work... Precautions... Connecting

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

Keypad Lock. Operation and Service Manual. Order parts online

Keypad Lock. Operation and Service Manual. Order parts online Keypad Lock Order parts online www.follettice.com Operation and Service Manual 801 Church Lane Easton, PA 18040, USA Toll free (800) 523-9361 (610) 252-7301 Fax (610) 250-0696 www.follettice.com 00163345R00

More information

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 1 / SEAV LRS 2102 R ++ SET

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 1 / SEAV LRS 2102 R ++ SET CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 1 / SEAV LRS 2102 R ++ SET 230 Volt Single Phase logic control panel for single motor only sliding gate, roller garage door, single leaf swing gate Integral

More information

InView Marquee Message Display

InView Marquee Message Display Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.

More information

Sarix Professional IMP Series 3.75 Indoor Dome. Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16)

Sarix Professional IMP Series 3.75 Indoor Dome. Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16) Sarix Professional IMP Series 3.75 Indoor Dome Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16) Sarix Professional IJP Series 2 Micro Indoor Dome Quick Start Guide IJP121-1IS

More information

Control panel installation manual for QIK80EH barrier. Safety switch 24V= ENC BIXMR2 COM PRG POWER. Automatic closing. Closing.

Control panel installation manual for QIK80EH barrier. Safety switch 24V= ENC BIXMR2 COM PRG POWER. Automatic closing. Closing. FUSE Ditec EL34 Control panel installation manual for QIK80EH barrier (Original instructions) IP2152EN Transformer Motor 24V= Safety switch TRF 24V~ EL34 12 11 0 ENC + M - BIXMR2 COM AUX AUX PRG GOL4 VA

More information

Installation Manual BAK02

Installation Manual BAK02 Installation Manual BAK02 XXXXXXXX/10-02-2014 Attention. Before installing the equipment, carefully read the SAFETY WARNINGS contained in the package as they provide important instructions regarding the

More information

Daily use. indicating that the loud speakers

Daily use. indicating that the loud speakers BeoLab 8002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equipment to dripping or splashing and ensure that no objects

More information

PC170 Control Box USER MANUAL 24V DC GEAR MOTOR FOR RESIDENTIAL

PC170 Control Box USER MANUAL 24V DC GEAR MOTOR FOR RESIDENTIAL PC170 Control Box 24V DC GEAR MOTOR FOR RESIDENTIAL USER MANUAL INDEX 1. CONTROL BOX 2. SETTING 2.1 SW1 DIP SWITCH SETTING 2.1.1 SLOWDOWN ADJUSTMENT (DIP 1. SLOW) 2.1.2 OVER-CURRENT ADJUSTMENT (DIP 2.OVER

More information

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide EnviroNET 2100 Series Ethernet Extender Quick Start Guide Important This is a Class A device and is intended for use in an industrial environment. It is not intended nor approved for use in a residential

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

&%=579 OPERATING INSTRUCTIONS

&%=579 OPERATING INSTRUCTIONS &%=579 OPERATING INSTRUCTIONS INDEX INDEX...1 INTRODUCTION...2 Packing contents... 2 Contents of this Instruction Manual... 2 Addressee of the Instruction Manual... 2 What to read... 2 Typographic conventions...

More information

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216

More information

LC2300 Level Controller Installation and Maintenance Instructions

LC2300 Level Controller Installation and Maintenance Instructions 4025350/5 IM-P402-72 AB Issue 5 LC2300 Level Controller Installation and Maintenance Instructions 1 General safety information LC2300 2 General product information 3 Installation >50% >100%

More information

Capacitive Proximity Sensor E2K-X

Capacitive Proximity Sensor E2K-X Sensing Supply voltage Output 90 to 0 VAC, 0/60 z to 30 VDC 00 ma, 8, 1 mm 00 ma NPN or PNP Capacitive Proximity Sensor Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact

More information

7 Day Programmable Room Thermostat

7 Day Programmable Room Thermostat 7 Day Programmable Room Thermostat Model: TRT035N Installation & Operating Instructions 1. General Information These instructions should be read carefully and retained for further reference and maintenance.

More information

Power supply module, bus connection module

Power supply module, bus connection module s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can

More information

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03 Outdoor PTZ Mounting on the Ceiling Using Pendant Mount For Models: I93, I94, I95, I96, KCM-8211 2013/12/03 Table of Contents Mounting Solutions... 3 Straight Tube Installation Procedures... 4 Step 1:

More information

Technology Security Low consumption

Technology Security Low consumption Control units Technology Security Low consumption TECHNOLOGICAL SOLUTIONS FOR SECURE OPERATION All the latest generation V2 control units can be configured via smartphone and tablet, with V2AppTool. The

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers Type volume flow controllers series volume flow controllers General information Correct use Safety notes Area of application Operating modes Product description Installation 4 Commissioning and wiring

More information

Dome Camera. Hardware Manual Z81, Z /01/08

Dome Camera. Hardware Manual Z81, Z /01/08 Dome Camera Hardware Manual Z81, Z82 2018/01/08 Table of Contents Precautions 3 Regulatory Compliance... 4 Safety and Compliance Information... 5 Introduction 7 List of Models... 7 Package Contents...

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

Operating and Maintenance Instructions

Operating and Maintenance Instructions Part No Description Dual EC Fan Controller Issue Date Bug no Comments 1 10 July 2012 1205 Signed CE front sheet & instructions clarified 2 28 Jan 2013 1205 Instructions clarified, identify Live & SELV

More information

MC61PL USER/INSTALLER MANUAL MC61-PL-3.6

MC61PL USER/INSTALLER MANUAL MC61-PL-3.6 MC61PL USER/INSTALLER MANUAL MC61-PL-3.6 00. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW ATTTION: This product is certified in accordance with European Community (EC) safety standards. This product complies

More information

Nice RB600/600P RB1000/1000P RB500HS RB500HS/V1

Nice RB600/600P RB1000/1000P RB500HS RB500HS/V1 Nice RB600/600P RB1000/1000P RB500HS RB500HS/V1 For sliding gates EN - Instructions and warnings for installation and use CONTENTS GENERAL WARNINGS: SAFETY - INSTALLATION - USE 2 1 - PRODUCT DESCRIPTION

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TS1000C TS700C INSTALLATION INSTRUCTIONS CONTENT: 1. Important safety instructions. 2. Specifications and main dimensions. 3. Parts included. 4. Installation. 5. RF remote system. 6. Feature functions

More information

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443 Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443 IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY. PARTS LIST: 2 Metal Plate Stands 5 Greenery

More information

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000 1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.

More information

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions BlueGuard FE Bluetooth Enabled Access Control MODEL BG-FE Operating Instructions CAUTION AND SAFETY INFORMATION IMPORTANT: If the equipment is used in a manner not specified in this manual, the protection

More information

COMMERCIAL. VAM24-90-(A) Series Installation Instructions

COMMERCIAL. VAM24-90-(A) Series Installation Instructions MERCIAL VAM24-90-(A) Series Installation Instructions Bray Controls Commercial Division 13788 West Road, Suite 200A Houston, Texas 77041 BCDSales@Bray.com Phone: 1-888-412-2729 Fax: 1-888-412-2720 www.braycommercialdivision.com

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Safety Interlock Switches TL8012-S TL8012 For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Versatile Safety Interlock

More information

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual Zartek CDP-808 Two Button Wireless Intercom Installers Manual ZA-614 Two Button Gate station including power supply, relay board and external antenna ZA-613 Handsets with charger ZA-613-E Handsets with

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

LED W RGBA User Manual

LED W RGBA User Manual LED- 245-1W RGBA User Manual Please read the instructions carefully before use CONTENTS 1. Safety Instructions...2 2. Technical Specifications...3 3. How To Set The Unit...4 3.1 Control Panel...4 3.2 Main

More information

Mounting and Operating Instructions EB EN. Electric Actuators with LON Interface. Type 5824 without Type 5825 with fail-safe action

Mounting and Operating Instructions EB EN. Electric Actuators with LON Interface. Type 5824 without Type 5825 with fail-safe action Electric Actuators with LON Interface Type 5824 without Type 5825 with fail-safe action Fig. 1 Type 5824 Actuator Mounting and Operating Instructions EB 5824-9 EN Edition June 2003 Contents Contents Page

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

smartentry Wireless Video Doorphone User Manual

smartentry Wireless Video Doorphone User Manual smartentry Wireless Video Doorphone User Manual Designed & Engineered Version 1.2 in the United Kingdom Contents Precautions... 3 1. Product Overview... 4 1.1. Product Features... 4 1.2. Contents... 4

More information

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions Push-button sensor module Ref.-no.: 4008 TSM Safety instructions Caution! Electrical devices may only be installed and fitted by electrically skilled persons. Non-compliance with the installation information

More information

OPERATING INSTRUCTIONS WCU17

OPERATING INSTRUCTIONS WCU17 OPERATING INSTRUCTIONS Index 000 Translation of the original instructions 10999826 en / 05.10.2018 Congratulations! You have decided to purchase a tried-and-tested TYROLIT Hydrostress unit and have thus

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket

More information

Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F035-20/E Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32 1 MODEL CODE AGMZO Proportional pressure relief valve

More information

JULIET-PK. Joystick station

JULIET-PK. Joystick station Joystick station JULIET-PK Handy and compact joystick station. Juliet PK is a user-friendly, ergonomic product, whose size and shape are the result of careful analysis of the aspects linked to daily use

More information

SLIMBAT2 wireless photocell MANUAL

SLIMBAT2 wireless photocell MANUAL v.1.1 1. of the device The wireless photocell is a safety element in gate automation. Between the transmitter and the receiver, the infrared beam is created, forming invisible to the human eye barrier.

More information

MOTOREDUCER FOR SLIDING GATES AG WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

MOTOREDUCER FOR SLIDING GATES AG WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack MOTOREDUCER FOR SLIDING GATES AG 2000 WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack Our products if installed by qualified personnel capable to evaluate

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

icore Kiosk system Installation Guide

icore Kiosk system Installation Guide icore Kiosk system Installation Guide The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights,

More information

Ditec NeoS Automation system for sliding gates up to 1000 Kg

Ditec NeoS Automation system for sliding gates up to 1000 Kg INTELLIGENT SAFE 24 V VIRTUAL ENCODER VERSATILE SETTING Ditec NeoS Automation system for sliding gates up to 1000 Kg EN www.entrematic.com Sturdy and Reliable Ditec NeoS is a sliding-gate operating device

More information

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

KEY POINTS TO PAY ATTENTION TO

KEY POINTS TO PAY ATTENTION TO USING THE BOOM GATE - GENERAL DESCRIPTION - The ASA600012V boom gate is suitable for managing passageways with average levels of transit. - The movement of the boom is regular with gradual decelerations

More information

Neptis AUTOMATIC SWING DOORS FOR PEDESTRIANS SLT-B LET-B SMT-B SLT LET SMT. English Translation of the ORIGINAL INSTRUCTIONS.

Neptis AUTOMATIC SWING DOORS FOR PEDESTRIANS SLT-B LET-B SMT-B SLT LET SMT. English Translation of the ORIGINAL INSTRUCTIONS. USER MANUAL AUTOMATIC SWING DOORS FOR PEDESTRIANS GB Neptis SLT-B LET-B SMT-B SLT LET SMT Made in Italy by English Translation of the ORIGINAL INSTRUCTIONS USER MANUAL - NEPTIS-16005_GB_Rel.1.0_04/2013

More information

SMVector Additional I/O Module Installation and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in

More information

Please keep these instructions for further reference.

Please keep these instructions for further reference. C 4 / C 5 GB Instructions for Initial Operation and Wiring Scheme Manual Door Operator for Industrial Use Please keep these instructions for further reference. . Contents Chapter Page. Contents. Meaning

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

Full HD Speed Dome IP Camera

Full HD Speed Dome IP Camera Full HD Speed Dome IP Camera Installation Guide Indoor / Outdoor Ver. 1.6 Preface The information given in this manual was current when published. The company reserves the right to revise and improve its

More information

Universal Safety Photo Eye UL MONITORED DEVICE

Universal Safety Photo Eye UL MONITORED DEVICE IRB-MON Universal Safety Photo Eye UL325-2016 MONITORED DEVICE Operating Instructions CAUTIONS AND WARNINGS This product is an accessory or part of a system. Always read and follow the manufacturer s instructions

More information

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL325-2016 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com Technical Support:

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

ACCESSORIES FOR SAFETY DEVICES

ACCESSORIES FOR SAFETY DEVICES ACCESSORIES FOR SAFETY DEVICES - SE-DM: series: deviating mirrors - SE-LP: series: laser pointer - SE-S: series: floor stand - SE-SR2 series: safety relay - SE-SRT series: connection box INSTALLATION SE-DM

More information

Universal digital indicator 4½-digit

Universal digital indicator 4½-digit SENSORS FOR FOOD AND BIOPHARMA. Product Informati PEM-UC CONTROLS Universal digital indicator ½-digit Applicati/specified usage Machine and switch cabinet cstructi Indicating and transforming of process

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Rotary Position Technology Incremental Encoders

Rotary Position Technology Incremental Encoders -40 to 85 C IP Safety-Lock High rotational speed Temperature High IP High shaft load capacity Shock/vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection Optical sensor

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

INSTALLATION SUPPLY DOES NOT INCLUDE THE BRACKETS SUPPORTING THE WINDING TUBE AND ELECTRICAL COMPONENTS.

INSTALLATION SUPPLY DOES NOT INCLUDE THE BRACKETS SUPPORTING THE WINDING TUBE AND ELECTRICAL COMPONENTS. INSTALLATION 2 3 4 5 6 7 9 8 10 LEGEND: 1. Movement chain 2. Electrical motor 3. Winding tube 4. Strap fastening 5. Central winding roller 6. Side winding roller 7. Terminal chain 8. Winding tube plug

More information

DE EN. TeLephOne ReMOTe COnTROL FOR Eberspächer parking heaters A WORLD OF COMFORT

DE EN. TeLephOne ReMOTe COnTROL FOR Eberspächer parking heaters A WORLD OF COMFORT Vehicle heaters Technical Documentation DE EN Installation instructions Calltronic TeLephOne ReMOTe COnTROL FOR Eberspächer parking heaters A WORLD OF COMFORT 2 Vehicle Heaters Technical Documentation

More information

User Guide Automatic Transfer Switch (ATS)

User Guide Automatic Transfer Switch (ATS) User Guide Automatic Transfer Switch (ATS) V.1.0 Table of Contents 1. Introduction... 2 2. Product Overview... 2 3. Important Safety Warnings... 3 4. Operation Indicators & Status... 3 5. Installation...

More information

Assembly and Operating Instructions Door Control

Assembly and Operating Instructions Door Control S10 GB Assembly and Operating Instructions Door Control Important information for: Fitters Electricians Users Please forward accordingly! These instructions must be kept for future reference. Assembly

More information