Limit switches Instrument sensors
|
|
- Annice Potter
- 5 years ago
- Views:
Transcription
1 Limit switches Instrument sensors Construction GEMÜ 12 Limit switch with built-in bistable reed contact (change-over) GEMÜ Limit switches with built-in bistable reed contact (NO) GEMÜ Instrument sensors with built-in chain of reed contacts which have a voltage output signal via a voltage divider (0-10 KΩ). GEMÜ Instrument sensors with built-in chain of reed contacts and integrated 2-wire measuring transducer which produces a current output signal. Features Function independent of operating pressure, conductivity, concentration or density of the medium Can also be used with opaque medium Simple mounting by clamping to flowmeter ATEX version optional Function The limit switches and instrument sensors are clamped to the dovetail sections moulded onto the flowmeter series GEMÜ 800 and GEMÜ 8 (see data sheets 800/8). The float in the flowmeter is equipped with a permanent magnet for this application which triggers the reed contact / chain of reed contacts. GEMÜ Reading of the level of the float at the switching points Position of the float in relation to the contact: above contact below contact Max. contact (GEMÜ 1251/1256) closed open Min. contact (GEMÜ 1252/1257) open closed GEMÜ Continuous reading of the level of the float Side views
2 Technical data GEMÜ General information Protection class IP 65 Housing material PBTP Approvals ATEX AT1 II2G IIB T6 X Note on index X (ATEX): Operation in potentially explosive areas only in conjunction with an isolator amplifier complying with ATEX which is designed for operating electro-mechanical switching contacts and for which separate operating instructions apply. Electrical data GEMÜ 12 Switching voltage DC or Peak AC 175 V Switching current DC or Peak AC 0,5 A Switch rating 10 W GEMÜ Switching voltage DC or Peak AC 2 V Switching current DC or Peak AC 1,0 A Switch rating 100 W Switching contacts Contact Bistable reed contact (change-over) (GEMÜ 12) Bistable reed contact (NO) (GEMÜ ) Contact function Change-over contact (GEMÜ 12) Max. contact (GEMÜ 1251, 1256) Min. contact (GEMÜ 1252, 1257) Connection Connector plug Plug design B, Industrial standard (supplied with the unit as standard) Electrical connection GEMÜ 12 GEMÜ internal external internal external Order data GEMÜ Type Limit switch, change-over contact for GEMÜ 811,815,816,817,830,831,832,835; DN and GEMÜ 861,865,867,880,881,885; DN Limit switch, max. contact for GEMÜ 811,815,816,817,830,831,832,835; DN and GEMÜ 861,865,867,880,881,885; DN Limit switch, min. contact for GEMÜ 811,815,816,817,830,831,832,835; DN and GEMÜ 861,865,867,880,881,885; DN Limit switch, max. contact DN Limit switch, min. contact DN Nominal size Without 000 Option Without 00 ATEX zone No ATEX evaluation 000 one 1 ( IIGD IIC T6 X) AT1 Order example Type (code) 12 Nominal size (code) 000 (code) Option (code) 00 ATEX zone (code) 000 2
3 Dimensions [mm] GEMÜ 12, 1251, , GEMÜ 1256, ,8 3
4 Technical data GEMÜ General information Protection class IP 65 Housing material ABS Approvals ATEX AT1 II2G IIB T6 X (only 1270 / 1271) AT2 II3G EEx na II T6 Note on index X (ATEX AT1) Operation in potentially explosive areas only in conjunction with a safety barrier complying with ATEX which is designed for operating passive resistor elements or potentiometers and for which separate installation, operating and maintenance instructions apply. Electrical data Power supply Uv (1270 / 1271) max. 24V DC Umin (1272 / 1273) 11V DC A x load resistor (Ohm) (For values see diagram) Umax (1272 / 1273) 40V DC (For values see diagram) Max. power consumption V x 20 ma Current output 4 20 ma Detection of measured values Detection of measured values Series of reed contacts connected to a chain of resistors, 0-10 kω Connection Connector plug Plug design B, Industrial standard, (supplied with the unit as standard) Supply voltage GEMÜ 1272, 1273 Voltage [V] Load resistor [Ω] Current [ma] max. permissible voltage 40V Load resistor max Ω Load resistor Device type For flowmeter type Measuring transducer Metering length Number of switch points Distance of reed contacts GEMÜ without 230 mm mm GEMÜ without 230 mm mm GEMÜ , 8 (DN10-20) without 118 mm mm GEMÜ (DN25) without 147 mm mm GEMÜ mm mm GEMÜ mm mm GEMÜ , 8 (DN10-20) 118 mm mm GEMÜ (DN25) 125 mm mm Electrical connection GEMÜ 1270, 1271 GEMÜ 1272, wire connection U J internal external internal external 4
5 Order data GEMÜ Type Instrument sensor with voltage divider for GEMÜ 811,815,816,817,830,831,832,835; DN Instrument sensor with voltage divider DN Instrument sensor with 2-wire measuring transducer for GEMÜ 811,815,816,817,830,831,832,835; DN Instrument sensor with 2-wire measuring transducer DN Series GEMÜ 840,841,845,846, 861,865,867,880,881,885; DN GEMÜ 861,865,867,880,881,885; DN 25 GEMÜ 811,815,816,817,830,831,832,835; DN Resolution 35 contacts 1271 / 1273 series contacts 1271 / 1273 series contact 1270 / contacts 1270 / Nominal size Without 000 ATEX zone No ATEX evaluation 000 one 1 II2G IIB T6 X (only type 1270, 1271) one 2 II3G EEx na II T6 (only type 1270, 1271) AT1 AT2 Order example Type (code) 1270 Nominal size (code) 000 (code) Series (code) 10 Resolution (code) 01 ATEX zone (code) 000 5
6 Dimensions [mm] GEMÜ 1270, 1272 GEMÜ 1271, DN DN 25 4, ,5 23,2 32, , , ,4 4, , 5 23,2 32, Technical data sheet GEMÜ flowmeters Should there be any doubts or misunderstandings, the German version of this data sheet is the authoritative document! GEMÜ 800 GEMÜ 840 GEMÜ 8 For further accessories and other products, please see our Product Range catalogue and Price List. Contact GEMÜ. Subject to alteration 03/ VALVES, MEASUREMENT AND CONTROL SYSTEMS GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG Fritz-Müller-Str. 6-8 D Ingelfingen-Criesbach Tel. +49(0) 7940/123-0 Telefax +49(0) 7940/ info@gemue.de
Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75
Level Transmitter Construction The GEMÜ level transmitter has an immersion tube with reed contacts and a chain of resistors which are triggered by a float with an integrated permanent magnet. A threaded
More informationGEMÜ 4232 Travel sensor for linear actuators
Travel sensor for linear actuators Features ATEX version available as an option Easy fitting to GEMÜ linear actuators Compact, stable housing Durable Can be retrofitted to GEMÜ valves or third-party actuators
More informationAS-Interface I/O Module
AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard
More informationElectrical Position Indicator
Distributed by: Tel: 90.77.9000 Toll Free:.800.8.78 www.tricanada.com Electrical Position Indicator with microswitches Construction The GEMÜ 0 electrical position indicator has one or two mechanical microswitches.
More informationMotorized quarter turn actuator
Motorized quarter turn actuator Construction The GEMÜ 98 motorized quarter turn actuator is a compact design. The motor and gear are combined as one unit in a plastic housing. The quarter turn actuator
More information410, 417, 423. Butterfly valve, Plastic
Butterfly valve, Plastic Construction GEMÜ 410, 417 and 423 are centric butterfly valves in nominal sizes N 15-100. The valve body is made of PVC-U, the butterfly disc is made of PVF or PP. The available
More informationBall valve Metal. Sectional view. * see information on working medium on page PED/97/23/EC Category III Module H TA-LUFT
all valve Metal Construction GEMÜ is a 2/2-way stainless steel ball valve with top flange EN ISO 5211 in sizes DN 15 to 100. It has a low maintenance electric actuator with a powerful DC motor. The reduction
More informationMagnetically Inductive Flowmeter
Magnetically Inductive Flowmeter Construction The GEMÜ mflow flowmeter operates according to the magnetically inductive measurement principle. It is suitable for electrically conductive media and enables
More informationGEMÜ 9468 Motorized quarter turn actuator
Motorized quarter turn actuator Features Increased torque in the end positions with consistent motor load/rotational speed through threaded spindle kinematics (closing curve matched to valves) Low weight
More information711, 728, 751. Ball Valve, Stainless steel Multi-port
Ball Valve, Stainless steel Multi-port Construction GEMÜ 711, 728 and 751 are 2/2-way stainless steel ball valves with top flange EN ISO 5211 in sizes 1/4 to 2 (DN 8 to DN 50). The top flange enables both
More informationLS series. Electrical Position Indicators for Quarter Turn Actuators
0 Electrical Position ndicators for Quarter Turn Actuators Construction The GEMÜ electrical position indicators are used to indicate and monitor the position of quarter turn valves. Depending on the version,
More informationGEMÜ 1235 Electrical position indicator
Electrical position indicator Features Communication and programming interface IO-Link Adjustable switch point tolerances Speed-AP function for fast mounting and initialisation High visibility position
More informationLevel sensor Stainless steel version Model RLT-1000, for industrial applications
Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring
More informationGEMÜ 723 Motorized ball valve
Motorized ball valve Features High flow rates Low weight Choice of various body materials and connection types Available as shut off or control valve / and /-way versions available The / and/or /-way ball
More informationNew! CleanStar SonicLine High Purity PFA Ultrasonic Flowmeters. Extended low flow measuring range ⅜" unit: l/min.
CleanStar SonicLine High Purity PFA Ultrasonic Flowmeters Product overview and technical data New! Extended low flow measuring range ⅜" unit: 0.03-6 l/min. VALVES, MEASUREMENT AN CONTROL SYSTEMS Synergy
More informationSafety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.
Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers
More informationADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.
EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier
More informationDMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationRSK. Wafer Type Check Valve. Construction. Features. Advantages
Wafer Type Check Valve Construction The GEMÜ wafer type check valve is available in plastic or metal and the body, disc and seal can be chosen from various materials. The valve is clamped between two flanges
More informationTRICOR Series TCM Coriolis Mass Flow Meters
TRICOR Series TCM Coriolis Mass Flow Meters Technical Datasheet TCM_E68_D_EN_150122_E002 TRICOR - Coriolis Mass Flow Meters Description The TRICOR Mass Flow Meters measure simultaneously mass flow, volume
More informationVariable Area Flowmeter DATASHEET
Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength
More informationThis explosion proof Pulse Generator is equipped with an inductive sensor for use in
Quick reference 50 pulses per revolution of measuring drum For use with TG05 to TG50 and BG4 to BG100 Uni-directional Applicable for ex-proof areas (1) Application The Pulse Generator for RITTER Drum-type
More informationIntrinsically Safe Barriers
Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper
More informationInstallation Manual Series PQ-L. Electronic Module. Bulletin /UK
Bulletin 5715-571 /UK Installation Manual Electronic Module Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+) 2131-513-0 Fax: (+) 2131-513-230 www.parker.com Copyright Ó 2000, Note This document and other
More informationPI-EX-ME-2NAM/COC-24VDC
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC
More informationLevel sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H
Level measurement Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H KSR data sheet FFG-P, FFG-T, FFG-TP, FLM-H Applications High-accuracy level measurement
More informationARI-PREMIO Plus 2G Electric thrust actuator with fail-safe function
ARI-PREMIO Plus 2G Electric thrust actuator with fail-safe function Electric thrust actuator with fail-safe function ARI-PREMIO Plus 2G Electric thrust actuator with fail-safe function ARI-PREMIO Plus
More informationFloat Switches with Permanent Magnet For Horizontal Installation Model HIF
Level Measurement Float Switches with Permanent Magnet For Horizontal Installation Model HIF WIKA Data Sheet LM 30.02 Applications Level measurement for almost all liquid media Pump/level control Chemical
More informationPHOENIX CONTACT - 12/2007
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel
More informationPI-EX-ME-2NAM/COC-120VAC
PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description
More informationPneumatic Control Unit for the integrated mounting on process valves
Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator
More informationMagnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting
More informationSignal processor MS96 for flow sensors MS96-11EX0-R/230VAC
MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment
More informationInductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationSignal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information
Signal conditioning instruments for level switches Conductive VEGATOR C VEGATOR VEGATOR Product Information Content Content Product description..........................................................................
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationMINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description
Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,
More informationApplication The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.
DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationSideControl Positioner
SideControl Positioner Electropneumatic positioner for pneumatically actuated process valves II (1) 2 G EEx ia IIC T6 approval can be combined with... Type 2712 Globe valve Globe valve acc. to NAMUR/IEC
More informationLevel measurement. Applications. Special features. Description
Level measurement Optoelectronic level switch Model OLS-S, for the process industry (with Ex i approval: KSR-OPTO.21*06XX) Model OSA-S, switching amplifier (with Ex i approval: KSR-OPTO.2502.XX) KSR data
More informationLMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.
LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:
More informationIndicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED
Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure
More informationSeparating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information
Separating and protective instruments Separating and protective instruments VEGATRENN 149AEx Separator type KFDO Barrier type 9001 Product Information Content Content 1 Product description..........................................................................
More informationInductive sensor BI1.5-EG08-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)
More informationMINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description
Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.
More informationInstruction Manual, Alfa Laval Rotacheck Sensor and Relay
Instruction Manual Alfa Laval Rotacheck Sensor and Relay Covering Standard Instruments Instruments delivered with ATEX Certification in accordance with Directive 94/9/EC IM-TE91A663-EN9 ESE01763EN Date
More informationDigital Positioner 8049
Compact digital positioner for pneumatic control valves. Positioner can be integrated into valve actuator (no external moving parts for stroke feedback) Wide range of strokes - 8 mm No steady-state air
More informationReed sensor For bypass level indicators Model BLR
Level measurement Reed sensor For bypass level indicators Model BLR WIKA data sheet LM 10.04 for further approvals see page 3 Applications Sensor for the continuous level measurement of liquids in bypass
More informationSeries 3730 Electropneumatic Positioner Type
Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm
More informationC-Flow Coriolis Mass Flow Meter
Coriolis Mass Flow Meter Application and Features For fluids (e.g. PU components, paints) and gases of high density Suitable for aggressive and contaminated media Measurement of mass flow, density, temperature
More informationSIMATIC Distributed I/O Product information for the ET 200iSP Operating Instructions (A5E ) 01/2010
SIMATIC Distributed I/O Product information for the ET 200iSP Operating Instructions (A5E00247483-04) 01/2010 Product Information Order number Type Order number 4 DO DC23.1V/20mA SHUT DOWN "H" 6ES7132-7RD01-0AB0
More information4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F
4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to
More informationLevel sensor for monitoring the level of liquid media
Level sensor MG Level sensor for monitoring the level of liquid media Characteristics Level sensor output 4 20mA or Resistance output in three-wire potentiometer circuit Temperature range: -30 C to 150
More information4 â RIA251. Technical Information. Process display Digital loop powered display for ma current loops
Technical Information RIA251 Process display Digital loop powered display for 4...20 ma current loops Application Plant and machine construction Control panels Laboratory fittings Process display, monitoring
More informationFloat Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65
Float Flow Meter Flow measurement for translucent liquids and gases DN10 to DN65 mm If a medium sufficient flow rate flows from bottom to top through a vertically inserted measuring tube, then the floated
More informationMagnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationMagnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationMINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description
Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationPHOENIX CONTACT - 05/2007
Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007
More informationOperating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505
Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating
More informationDigital Output Module 8-Channel Version for Zone 1 Series 9475/
www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationGround Monitoring Device Series 8485
www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with
More information97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT
70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination
More informationMagnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationHydrostatic filling level sensor HFB C4 / R / MD
Hydrostatic filling level sensor HFB C4 / R / MD Pressure measuring range 0-0.5 bar Voltage supply 18 30 V DC Features Filling level detection through measuring the hydrostatic medium pressure by means
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationML7421A,B Electric Linear Valve Actuators
ML7421A,B Electric Linear alve Actuators FEATURES Quick and easy installation No separate linkage required No adjustments Force-limiting end switches Manual operator Synchronous motor Corrosion-resistant
More informationInductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationOnline data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES
Online data sheet A B C D E F H I J K L M N O P Q R S T Ordering information Type Part no. On request The exact device specifications and performance data of the product may deviate from the information
More informationDigital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.
Digital Frequency Divider INSTRUCTION MANUAL CONTENTS 1. Working Principle 2 2. Installation 2 3. Setting Up 3 4. Technical Data 4 Code: 189/1a 1 WORKING PRINCIPLE The DFD has been designed to generate
More informationMINI MCR-SL-PT100-UI-200
Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is
More informationInductive sensor with analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection
More informationSUBCON-PLUS-PROFIB...
Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12
More information97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free
More informationDMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML
DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML 11.20 DMA 40 P 230/02 3 L DMA 30 P 230/03 0 L DMA 30 Q 230/ 0 L DMA 30 A 230/ 0 L Printed in Germany Edition 02. Nr. 229
More informationPTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions
Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Example / Beispiel / Exemple Type 6106 Operating Instructions Bedienungsanleitung Manuel d utilisation
More informationCapacitance level switches LS 210 LS 220
KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,
More information97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >
More informationPHOENIX CONTACT - 01/2008
Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex
More informationTrendmaster* Galvanic Isolator
162459-01 Trendmaster* Galvanic Isolator Product Datasheet Bently Nevada* Asset Condition Monitoring Description The Trendmaster Galvanic Isolator enables the Trendmaster system to connect to intrinsically
More informationLMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.
LMP 08i Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mh O up to 0... 00 mh O Output signals wire:... 0 ma wire:
More informationSensyflow FMT200-ECO2 Thermal Mass Flowmeter
Contents Data Sheet Rev. B Sensyflow FMT200-ECO2 Thermal Mass Flowmeter Direct mass flow measurement of air No additional pressure and temperature compensation required Mass flow or standard volume flow
More informationFlow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI
Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic
More informationPHOENIX CONTACT - 02/2008
Ex-i solenoid driver for Group IIC gases, loop-powered, pluggable INTERFACE Data Sheet 103211_00_en PHOENIX CONTACT - 02/2008 1 Description The solenoid driver PI-EX-SD-21-25 links a signaling device installed
More informationInductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi
ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring
More informationViscosity-Compensated Flow Meters and Switches
Viscosity-Compensated Meters and Switches for Viscous Liquids measuring monitoring analysing Range: Oil 0.01-0.07 to 8-80 L/min Basic accuracy: ±4% f. s. pmax 350 bar, tmax 100 C Viscosity range: 1...540
More informationT EN TROVIS Electropneumatic Positioner
T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.
More informationSYSTEM COMPONENTS SYSTEM COMPONENTS MODULES
SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES O U R P R O F E S S I O N MULTIFUNCTIONAL CURRENT CONTROLLED SWITCH MODULES MAIN FEATURES 4 20 ma input Relay output Rail mountable Intrinsically safe Associated
More informationOperating pressure (bar) kv factor (m 3 /h) *3)
/ way poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar
More informationInductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI
ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detecting angular positions of 0 to 360 P1-Ri-DSU35 positioning element included in delivery
More informationVALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified
More information