About this Manual. Description
|
|
- Kellie Wells
- 5 years ago
- Views:
Transcription
1 About this Manual This manual is a comprehensive guide that contains all of the information necessary to install and operate the Balluff BDD-100 Position Display. Please read this manual completely. For technical assistance, please contact: Balluff, Inc Holton Drive Florence, KY Description The Balluff BDD-100 is a 6-digit digital display, used in conjunction with the Balluff P1 RS-422 START/STOP linear transducer. The BDD-100 and the Balluff P1 linear transducer form a low-cost, easy to use system for displaying linear position. Easy to understand prompts make programming from the front panel fast and easy. Programming can also be done via the RS-232 port. Features Six-digit, 0.57 high, seven-segment LED display resolution Fixed 5 ms update rate Programmable decimal point, Units, and Gradient Remote Zero RS-232 serial interface for programming and data transfer Removable Phoenix-type connectors Front panel lock-out 24 Vdc input power 1
2 BDD-100 Position Display User s Guide Specifications Dimensions 1/8 DIN Display Six character, 7-segment LED Operating temperature 0 o C to 60 o C Humidity 95% Non-condensing Power requirements 24 Vdc +/- 150 ma maximum Resolution Update rate 5 ms Transducer type Balluff P1 START/STOP, trailing edge active Programming Via front panel or RS-232 interface Set-up and Operation Installation The BDD-100 should be installed in a sealed enclosure. Mounting is accomplished using the snap-clips provided (see Fig. 1 for mounting dimensions). BDD in (47.8mm) 3.76in (95.5mm) Fig. 1 Mounting dimensions 2
3 Wiring Wire the BDD-100 per the tables below: J1 8-pin Phoenix-type connector PIN FUNCTION WIRE COLOR* Vdc Brown 2 GROUND Blue 3 Interrogate + Yellow 4 Interrogate - Pink 5 Start/Stop+ Grey 6 Start/Stop- Green 7 Front Panel Disable n/a 8 Remote Zero n/a *Wire color applies to Balluff-supplied cable assemblies. J2 Communications Connector 3-pin Phoenix type PIN FUNCTION 1 RS232 Transmit 2 RS232 Receive 3 Ground +24 VDC Power Supply J1 +24 Vdc GND Interrogate + Interrogate - Start/Stop+ Start/Stop- Front panel disable Remote Zero RS-232 Tx RS=232 Rx GND J2 Fig. 2 Wiring diagram 3
4 BDD-100 Position Display User s Guide Front Panel Controls and Indicators BDD-100 Increment Enter/Zero Decrement Fig. 3 Mounting dimensions used during programming to step to the next parameter or to increment the displayed value used during programming to decrement the displayed value used during programming to accept the currently displayed value. Also used in RUN mode to zero the display. Setting Parameters The following parameters can be set via the front panel: ITEM DESCRIPTION DEFAULT Units Selects either INCHES (English) or English MILLIMETERS(SI) as unit of measure Resolution Expressed as number of digits after the 2 decimal point Count direction Expressed as POSITU or NEGATU. POSITU POSITU means that the count increases as the magnet moves away from the connector end of the transducer Gradient This is the calibration factor unique to µsec/inch each transducer. This number is printed on the transducer label. Depending on the unit of measure, this value is expressed in either microseconds per inch or meters per second. Offset Expressed in units Zero Set Enable Enables and disables the front-panel ENAB zero capability Save Saves the current settings to EEPROM n/a Factory Restores factory defaults n/a End Returns to the RUN mode n/a 4
5 Step-by-Step Programming Step1: Connect transducer and power supply per figure 2. Upon power-up, the display should show firmware version for approximately 2 seconds and then go into RUN mode with the current position being displayed. Step 2: Press and hold the and buttons simultaneously for approximately 1.5 seconds. The display should indicate Step 3: With displayed, press. Press the button to toggle between (inches) and (millimeters). Press to accept the desired setting. Step 4: Press the button once. The display should indicate. Press. The current display resolution is displayed. Use the or button until the desired resolution is displayed. Press to accept the value. Step 5: Press the button once. The display should indicate. Press. The display indicates either or. Use the or buttons to select the desired count direction. Press to accept. Step 6: Press the button once. The display should indicate. Press. The display will indicate the current gradient with the first digit flashing. Use the button to change the value of the flashing digit. Use the button to move the flashing digit one place to the right. Repeat this procedure until the desired value is displayed. Press the button to accept the value. If the unit of measure selected in step 3 is, this value will be displayed in microseconds per inch. If unit of measure is, this value will be displayed in meters per second. Note: The gradient factor printed on the transducer lavel is in microseconds per inch. Step 7: Press the button once. The display should indicate. Press. The current offset will be displayed with the first digit flashing. Use the button to change the value of the flashing digit. Use the button to move the flashing digit one place to the right. Repeat this procedure until the desired value is displayed. Press the button to accept the value. Step 8: Press the button once. The display should indicate. Press. Use the button to toggle between and. If is selected, pressing and holding the for approximately 1.5 seconds while in RUN mode will cause the display to read This feature can be disabled by selecting. Step 9: Press the button once. The display should indicate. Pressing will save the current values to non-volatile memory. These settings will be retained even after power-down. Note: If this step is not performed, the above settings will remain in effect only as power is applied to the BDD-100. Step 10: Note: Only perform this step if all factory default settings need to be restored, otherwise, skip to Step 11. Press the button once. The display should indicate. Pressing will restore the BDD-100 to factory default settings. Step 11: Press the button once. The display should indicate. Press to return to RUN mode. The display should now be showing the current position, using the settings just programmed. 5
6 Special Functions Remote Zero Pin 8 on connector J1 can be used to perform a remote zero. Momentarily connecting pin 8 to GROUND (pin 2) will cause the display to read This function cannot be locked out with the ENAB 0 parameter. Front Panel Lockout Pin 7 on connector J1 can be used to lock-out the front panel. Connecting pin 7 to GROUND (pin 2) will disable the keypad. This feature could be used with a key-switch to prevent unauthorized or accidental changing of stored parameters. Error Indications The BDD-100 has two possible error indications: This indicates no response fromthe transducer. Possible causes are: No transducer connected Faulty or incorrectly wired interconnecting cable between the BDD-100 and the transducer Faulty transducer This indicates that the transducer is responding, but there is either no magnet or the magnet is outside the active sensing range of the transducer. 6
7 Serial Communications The BDD-100 incorporates an RS232 port for serial communications. The RS232 port can be used for programming any or all of the set-up parameters. The port can also be used to retrieve data fromthe BDD-100. Wire the BDD-100 serial communications port (J2) per the table below. PIN Function 1 RS-232 Tx 2 RS-232 Rx 3 GND Protocol Baud Rate 9600 Data Bits 8 Parity N Stop Bits 1 Connection diagram J1 +24 Vdc GND Interrogate + Interrogate - Start/Stop+ Start/Stop- Front panel disable Remote Zero J2 RS-232 Tx RS=232 Rx GND Fig. 4 Serial Interface 7
8 Commands All messages sent to the display must begin with the $ character and end with a carriage return. All responses from the display end with a carriage return. The following command messages are recognized. Input Command Function Reponse (followed by CR) $RD Read the Direction POS or NEG $RG Read the Gradient $RO Read the Offset $RP Read the Position (decimal places determined by resolution) $RR Read the Resolution 3 $RU Read the Units ENG or SI $RZ Read the Zero Set Enable ENAB or DISAB Status $RS Read the Error Status NORMAL Normal operation NOMAGT No magnet on transducer or magnet outside active stroke NOTRNS No transducer connected or transducer not responding Output Command Function Parameter Response $WDxxx Write the Direction POS or NEG * $WF Write Factory Defaults None * $WGnnnnn Write the Gradient Gradient in units * WOnnnnn Write the Offset Offset in units * $WRn Write the Resolution Number of digits * $Wuxxx Write the Units ENG or SI * $WZxxxxx Write the Zero Set Enable ENAB or DISAB * Status Special Commands Command Function Parameter Response $! Allows the Write to EEPROM None None ($WE) command to immediately follow $WE Write to EEPROM (requires $! None * To immediately precede it) 8
Installation & Operation
LED Readout Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon
More informationProduct Specification for Transducer Display Model TDD2
TDD2 Manual January 26, 2007 Product Specification for Transducer Display Model TDD2 The TDD2 displays position information derived from a magnetostrictive transducer with Synchronous Serial Interface
More information-C5RS-LC RS232 EXTENDER
XTENDEX Series ST-C5RS-LC RS232 EXTENDER Installation and Operation Manual ST-C5RS-LC RS232 Extender Man249 Rev. 10/30/17 TRADEMARK XTENDEX is a registered trademark of Network Technologies Inc in the
More informationProduct Specification and User Manual for Transducer Display Model TDD2
TDD2 Manual November 13, 2009 Product Specification User Manual for Transducer Display Model TDD2 The TDD2 displays position information derived from a magnetostrictive transducer with Synchronous Serial
More informationProduct Specification for SAB-S-MODBUS
SAB-S-MODBUS May 9, 2011 Product Specification for SAB-S-MODBUS The SAB-S-MODBUS is a two-channel module that measures single or multiple magnet transducer position and returns this information to a host
More information2-Axis Counter BDD 622
2-Axis Counter BDD 622 Technical Description, User's Guide english No. 622-221 D/E. Edition 0701; Subject to modification. www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany
More informationProgrammable Meter for Analog Sensors/Transducers
Programmable Meter for Analog Sensors/Transducers Supply Voltage: 24 V ± 20 % Temperature Range: 0 to 70 C Interface: 0 to 10 V or 4 to 20 ma with over-voltage protection Resolution: 16-bit analog to digital
More informationDCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL
DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL 1 TABLE OF CONTENTS 1. MOUNTING INSTRUCTIONS 1.1 Standard DIN Rail mounting 1.2 Screw Mounting 2. FUSE REPLACEMENT 3. ASSEMBLING THE UNIT
More informationProduct Specification and User Manual for Transducer Display Model TDD2
TDD2 Manual November 13, 2014 Product Specification User Manual for Transducer Display Model TDD2 The TDD2 displays position information derived from a magnetostrictive transducer with Synchronous Serial
More information7561-PSD Manual Portable Battery Powered Indicator
7561-PSD Manual Portable Battery Powered Indicator Lebow Products Inc. 1728 Maplelawn Drive P.O. Box 1089 Troy, Michigan 48084-1089 (800) 803-1164 Phone: (248) 643-0220 FAX: (248) 643-0259 Visit our web
More informationProduct Specification and User Manual for Transducer Display Model TDD2
TDD2 Manual January 27, 2017 Product Specification User Manual for Transducer Display Model TDD2 The TDD2 displays position information derived from a magnetostrictive transducer with Synchronous Serial
More informationLCM SYSTEMS. TR150 Portable Battery Powered Indicator. Instruction Manual. Software version V2.XX
TR50 Portable Battery Powered Indicator Instruction Manual Software version V2.XX CONTENTS What is TEDS? Basic concept How it works Advantages Introduction User operation Electrical connection information
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationProScale LCD Readout Quick Start Guide
ProScale LCD Readout Quick Start Guide This Guide includes basic operation instructions for 950, General Purpose, Basic & In-Panel LCD Readouts For the Complete OPERATION Manual go to www.proscale.com/manuals.htm
More informationThe IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More informationSI3300. user and installation manual. 4-20mA/DC-Digital Display
SI3300 4-20mA/DC-Digital Display The SI3300 is a member of the SI3000 Readout Family. All members of the family are marked SI3000 on the front panel. This manual is specifically for the SI3300 Model with
More informationEtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X
EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...
More information5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.
5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 UM-600 6-Channel Monitor Version 2 Installation and Operation Manual Rev. G P/N145F-12990 PCO 00007462 (c)
More information955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS
Series ebrik INSTALLATION MANUAL LINEAR DISPLACEMENT TRANSDUCERS ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS Introduction The is an accurate programmable, auto-tuning, noncontact, linear
More informationInstallation Instructions for: Channel Thermocouple Amplifier
Installation Instructions for: 30-2204 4 Channel Thermocouple Amplifier The Advanced Engine Management (AEM) 4 channel thermocouple amplifier revolutionizes temperature measurements by providing laboratory
More informationSingle-Axis Counter BDD 611
Single-Axis Counter BDD 611 Technical Description, User's Guide english No. 611-150 D/E. Edition 0705; Subject to modification. Replaces edition 0701. www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765
More information955S BRIK. Series 955S Brik. Smart BRIK LDT ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS. Linear Displacement Transducer
Series 955S Brik Linear Displacement Transducer Installation Manual 955S BRIK Smart BRIK LDT ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS Introduction The 955S Smart Brik is an accurate programmable,
More informationIntech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to
More informationI/O SIGNAL CONDITIONER
Technical Data Sheet No. TD9809M Rev. F Date of Issue: December 9, 2009 OPERATING MANUAL I/O SIGNAL CONDITIONER CAUTION: THIS PRODUCT DOES NOT PROVIDE GALVANIC ISOLATION. DO NOT ATTEMPT USE OF THIS PRODUCT
More informationUser Manual. cmt-svr Startup Guide
User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet
More informationReference Guide METTLER TOLEDO WMH Weighing Platforms
Reference Guide METTLER TOLEDO Weighing Platforms Mettler-Toledo GmbH 2005 Doc.No. KA021, 42908713C Weighing Platforms Reference Guide Contents 1 Initial Setup... 4 1.1 Installation... 4 1.2 Electrical
More informationUSER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX
USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE
More informationuser and installation manual
SI3500 SI3500 ORBIT Digital Display The SI3500 is a member of the SI3000 Readout Family. All members of the family are marked SI3000 on the front panel. This manual is specifically for the SI3500 Model
More informationRK CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT OR START/STOP)
RK CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT OR START/STOP) Main characteristics Absolute transducer Strokes from 50 to 4000 (RK-_- -N/S) Digital output RS422 Start/Stop (RK-_-
More informationSC2SSi - analog to digital SSi interpolator for absolute position Electric Encoders
Sc2SSi Data Sheet, V 1.0a,May 2012 - analog to digital SSi interpolator for absolute position Electric Encoders The Analog to SSI Interpolator - provides (SSi) conversion of the native analog signals to
More informationAB300-Series Automated Filter Wheels
AB300-Series Automated Filter Wheels User Manual 1049478 August 2006 1. Introduction 1.1 Mission Statement Our mission is to provide our customers with reliable products, on time, and at a fair price.
More informationRK-4 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH THREADED HEAD
RK-4 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH THREADED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-4- -N/E/S) Digital output
More informationINDICATOR FOR PROCESS CONTROL. Love Controls. LCI108J-0x INSTRUCTION MANUAL. EDITION: January Valid for models with software version P-1
Love Controls INDICATOR FOR PROCESS CONTROL LCI108-0x LCI108J-0x INSTRUCTION MANUAL EDITION: January 2001 Valid for models with software version P-1 INTRODUCTION TO THE LOVE CONTROLS LCI108 SERIES This
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More information6-Channel Monitor. Installation and Operation Manual
3211 Fruitland Ave Los Angeles, CA 90058 Catalyst Monitor 6-Channel Monitor Version 2 Installation and Operation Manual Rev. H P/N145F-12964 PCO - 00009743 (c) Copyright 2015, Barksdale, Inc. All Rights
More informationIntech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RO4 Installation Guide. The 2300 series stations are designed to
More informationDIGITAL PANEL THERMOMETER
Love Controls DIGITAL PANEL THERMOMETER LCI108-2x LCI108J-2x INSTRUCTIONS MANUAL EDITION: February 2001 INTRODUCTION TO THE LOVE CONTROLS LCI108 SERIES This manual does not constitute a formal agreement.
More informationManual 601: : USB/RS232. Specifications. Contents. Options
Page 1 ATE-601 601: : USB/RS232 I/O Controller - 8 Inputs, 4/8 Relays The ATE-500/600 series is a range of modular I/O controllers. It uses small standardized boards which allows you to configure the system
More informationIntelligent Devices IDI 6005 Speed Sign Controller Technical Manual
Intelligent Devices IDI 6005 Speed Sign Controller 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights
More informationTransmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD
Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P10-485-LCD TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTIONS MANUAL V1.0x D 1 INTRODUCTION The RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P10-485-LCD transmitters
More informationicex-cmtm General specs and Installation guide
icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB
More informationTR150 Digital Readout Unit SL755. Impact Test Equipment Ltd & User Guide. User Guide
TR150 Digital Readout Unit SL755 Impact Test Equipment Ltd www.impact-test.co.uk & www.impact-test.com User Guide User Guide Impact Test Equipment Ltd. Building 21 Stevenston Ind. Est. Stevenston Ayrshire
More informationModel 305e OEM CO 2 concentration sensor
Model 305e OEM CO 2 concentration sensor preliminary Reference manual DIGITAL CONTROL SYSTEMS 7401 SW Capitol Hwy. Portland, OR 97219 USA 503/246-8110 503/246-6747 (fax) www.dcs-inc.net Scope...3 Introduction...3
More informationKnowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers
Knowledge Base Article Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Copyright 2009-2013 ISONAS Security Systems All rights reserved Table of Contents 1: INTRODUCTION...
More informationIntech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RTD6 Installation Guide. The 2300 series stations are designed to
More informationDual Interface LCD Display Controller
Dual Interface LCD Display & Keypad Controller Product specification Nov 2013 V0.a ByVac Page 1 of 11 Contents 1. Introduction... 3 2. Features... 3 3. BV4618, Comparison... 3 3.1.1. BV4618... 3 3.1.2....
More informationMetaphase DDC-3. Technologies USER MANUAL. Version 7.X August metaphase-tech.com. pg. 1
USER MANUAL Version 7.X August 2014 pg. 1 Overview Digital Dimming Controller () provides 0-10V voltage dimming control of three independent LED loads in increments of 0.1V. The may be remotely controlled
More informationMODEL DSI-1000 INCLINOMETER READOUT JEWELL INSTRUMENTS, LLC. 850 Perimeter Road Manchester, NH 03103
MODEL DSI-1000 INCLINOMETER READOUT JEWELL INSTRUMENTS, LLC 850 Perimeter Road Manchester, NH 03103 PHONE: (800) 227-5955 E-MAIL: sales@jewellinstruments.com TABLE OF CONTENTS Description Page 3 Specifications
More informationProduct Specification for CANbus to DeviceNet Transducer Gateway
XG CANbus to DeviceNet Transducer Gateway April, 00 Product Specification for CANbus to DeviceNet Transducer Gateway The XG CANbus to DeviceNet Temposonics Gateway gathers position information from as
More informationF6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode
-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add
More informationPOSICHRON PCQA Mounting Sets
PCQA Mounting Sets Mounting set PCQA-BFS1 with mounting clamps Isolation sleeve 46 Isolation strip Mounting clamp P 58 Option -BFW Mounting brackets for PCQA22 and PCQA24 Note: The option -BFW can only
More informationDPS Telecom Your Partners in Telecom Management Networks
DPS Telecom Your Partners in Telecom Management Networks Operation Guide LR24 Relay Card Table of Contents Overview...1 Table of Contents...1 Typical Relay Applications...2 Shipping List....2 Installation...2
More informationUser Manual. cmt-svr Startup Guide
User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet
More informationIn-Sight 7010C/7200C/7400C
The following sections list general specifications for the In-Sight vision system. Vision System Specifications Table 3-1: Vision System Specifications Specifications Minimum Firmware Requirement Job/Program
More informationMetaphase DDC-3. Technologies USER MANUAL. Version 7.X August metaphase-tech.com. pg. 1
USER MANUAL Version 7.X August 2014 pg. 1 Overview Digital Dimming Controller () provides 0-10V voltage dimming control of three independent LED loads in increments of 0.1V. The may be remotely controlled
More informationMobileView Junction Box
Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard
More informationDIGITAL PANEL THERMOMETER
Love Controls DIGITAL PANEL THERMOMETER LCI108-1x LCI108J-1x INSTRUCTION MANUAL EDITION: January 2001 INTRODUCTION TO THE LOVE CONTROLS LCI108 SERIES This manual does not constitute a formal agreement.
More informationRK-A CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER
RK-A CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH REMOTE ELECTRONICS (ANALOG OUTPUT) Main characteristics Absolute transducer with remote electronics structure Sensor available in three
More informationPOWERWISE INDAC SETUP MANUAL
POWERWISE INDAC SETUP MANUAL REVISION: 2.2 INDAC & EMONITOR GATEWAY An installation guide for the PowerWise indac. 2013 PowerWise, Inc. This manual may contain proprietary information about the product
More informationESCO OrchIdea PAS PUMP ACCESS SYSTEM CONTROLLER INSTALLATION GUIDE Version 1.7.7
ESCO OrchIdea PAS-6001 PUMP ACCESS SYSTEM CONTROLLER INSTALLATION GUIDE Version 1.7.7 OrchIdea PAS-6001 Table of Contents OrchIdea Quick Installation Guide System Architecture OrchIdea Interconnection
More informationUNIVERSAL CURRENT CONVERTER
UNIVERSAL CURRENT / VOLTAGE CONVERTER AC/DC Current / Voltage Analyzer The is the first CURRENT / VOLTAGE CONVERTER & ANALYZER ALL IN ONE - of the market. It allow you to connect all isolated current sensors.
More informationDL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017
DL-10 User Manual RS-485 Remote Temperature and Humidity English Ver. 1.0, Jul. 2017 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of one year from
More informationMSOC Communication Commonality with DPU/TPU/GPU 2000R Protective Relays
ABB Application Note MSOC AN-64A-00 Substation Automation and Protection Division MSOC Communication Commonality with DPU/TPU/GPU 2000R Protective Relays Introduction There seems to be some confusion with
More informationIndustrial Serial Device Server
1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device
More informationELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL
ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL. 60101 www.electronicdisplays.com ED206/406-115 4D N1 - KY DESCRIPTION: 2.25 in. or 4.0 in. high, red 7 segment display; Programmable up/downtimer
More informationBTL6-A_10-M -A1-S115. Data Sheet. english
BT6-A_10-M -A1-S11 english Data Sheet Balluff GmbH Schurwaldstrasse 9 76 Neuhausen a.d.f. Germany Phone +49 (0) 71 8/1-0 Fax +49 (0) 71 8/0 10 Servicehotline +49 (0) 71 8/1-70 E-Mail: balluff@balluff.de
More informationAS Keypad User Manual
AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output
More informationBV4542. I2C or Serial 16x2 with Keypad interface
BV4543 I2C or Serial 16x2 with Keypad interface Date Firmware Revision February 2018 Preliminary 11 Feb. 2018 1.1.1 Updated how serial works 16 Feb. 2018 1.1.3 Sleep updated Introduction This is an I2C
More informationVorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual
Vorne Industries 2000S Series Serial Input Alphanumeric Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 Telephone (630) 875-3600 Telefax (630) 875-3609 2000S Series Serial Input Alphanumeric
More informationMounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.
Section Mounting Dimensions / Viewing 2 Mounting Options 3 Section 2 Wiring Configuration 4 Section 3 Quick Set up Procedure 5 Section 4 Changing Intensity 6 Section 5 Option Summary 7 Section 6 Option
More informationThe INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided
Industrial 2-port Gigabit High Power PoE Injector, 24V~50V Input Support Features Supports 2x10/100/1000Base-T(X) for power and data Output Fully compliant with IEEE802.3at/802.3af standard Auto protection
More information3 Input Multiplexer Operation Manual
ProMUX-3 3 Input Multiplexer Operation Manual WARRANTY Accurate Technology, Inc. warrants the ProMUX-3 against defective parts and workmanship for 1 year commencing from the date of original purchase.
More informationOperating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!
Operating Bulletin Model BB3-232 and BB3-I-232 USB Multi-Drop Box The Fastest Flow Controller Company in the World! 1 10/16/2017 Rev.1 DOC-BB3232MAN 2 Introduction Alicat BB3-232 Multi-Drop Box Operating
More informationRK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD
RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output
More informationBOARD LEVEL PRODUCTS GPIB<->RS-422/RS-485 INTERFACE BOARD
BOARD LEVEL PRODUCTS RS-422/ INTERFACE BOARD DESCRIPTION The Model Serial Interface is a small, low cost interface board that interfaces serial devices with RS-422 or signals to the bus. The provides
More informationWiring Guide EP.NMINI. Version 1.02 Last Updated:
Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass
More informationProgrammable Meter for Analog Sensors/Transducers
Programmable Meter for Analog Sensors/Transducers Supply Voltage: 11-28 VDC (nominal 24 VDC) * If using a TDRO10A2 in current analog output mode 11.5-28 VDC Temperature Range: 0 to 70 C Interface: 0 to
More informationTELEDYNE HASTINGS INSTRUMENTS
TELEDYNE HASTINGS INSTRUMENTS INSTRUCTION MANUAL MASS FLOWMETER CONTROLLER READOUT POWERPOD-100 Manual Print History The print history shown below lists the printing dates of all revisions and addenda
More informationBV4531U. I2C or Serial 6 Way Relay
BV4533 Date February 2018 11 Feb. 2018 Firmware Revision 1.0.4 Preliminary 1.1.0 Serial Updated I2C or Serial 6 Way Relay 3 Sep. 2018 1.1.0 I2C corrections, trigger is not used Introduction This is an
More informationOperation / Installation Manual
Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com ATC II TM AUTOMATIC TORCH CONTROL Operation / Installation
More informationPRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet
Digital Process Meters Digital Process Meter for analog Sensors Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part
More informationThe information in this chapter will enable you to:
C H A P T E R ➆ Chapter Objectives Environmental The information in this chapter will enable you to: Electrical Specifications RP240 Connector Power Hardware Reference Use this chapter as a quick-reference
More informationSAB-QS Quick Start November 9, SAB-QS Quick Start SAB-QS TRANSDUCERS 1 X4. Figure 1: SAB-QS Connector and Jumper Placement
SAB-QS Quick Start November, 000 SAB-QS Quick Start This document aims to provide a systematic setup procedure to enable you to setup and use your SAB-QS as easily as possible. This guide will concentrate
More informationUser Manual. Mounting the TriSonica Mini
User Manual Overview This is the user s manual for the TriSonica Mini (TSM) family of products from Anemoment. It provides the information that users need to mount, orient, connect, receive data, and configure
More informationModel 3005 Analog Board. User s Guide
Siemens Energy, Inc. Oil & Gas Solutions 10730 Telge Road Houston, Texas 77095 USA Document No. SEI-OG-DLS-005 Page 1 of 6 Siemens AG 2011 Table of Contents 1 DESCRIPTION:... 3 2 CONFIGURATION... 3 3 OPERATION...
More informationICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter
ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus
More informationCA111x-series Arming Station
GE Security CA111x-series Arming Station Installation and Programming Guide Contents Page Product Overview...1 Removing the Covers...2 Mounting the RAS...3 Tamper Switch...3 DIP Switch Settings...3 Connections...4
More informationA Issue A Original. Instruction Manual. nxds Serial Comms Interface
Instruction Manual A735-01-860 Issue A Original nxds Serial Comms Interface Description nxds6i nxds10i nxds15i nxds20i Item Number A735-01-983 A736-01-983 A737-01-983 A738-01-983 nxds6ic nxds10ic nxds15ic
More information180 Series Keypad. Handbook. Revision 2.1
180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique
More informationINTMOD485-LH Protocol Converter
For Use with L-GAGE LH Series Sensors Features Converts an LH Network to the 485-RTU protocol Supports baud rates up to 230,400 baud Supports LH Networks with up to 32 sensors Model Protocol Conversion
More informationLiquid Volume Dispenser
Liquid Volume Dispenser Table of Contents 1. Introduction 3 2. Installation 3 3. Volume Accuracy 3 4. Operator Controls 4 5. Operating States 4 5.1 Ready 4 5.2 Dispensing 5 5.3 Manual Dispensing 5 5.4
More informationECS ecompass Series. ECS ecompass Series. Strap down Electronic Compass. General Description. Features. Making Sense out of Motion
ECS ecompass Series Strap down Electronic Compass General Description Features High Accuracy Heading within 0.5 or better Tilt within 0.2 or better Wide Operating Range ±42 Pitch and Roll ±80 Dip angle
More informationINSTALLATION INSTRUCTIONS 921P EntryCheck TM
80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount
More informationLM058 Bluetooth Serial Adapter
LM058 Bluetooth Serial Adapter with external antenna The LM058 Bluetooth Serial Adapter eliminates your conventional RS232 serial cables, providing an easy-to-use, invisible connection with freedom of
More informationSpecification. Current Consumption Range 8m * Rotational Angle +/- 50 degrees * Shear Angle +/- 40 degrees *
HX11TR Ultrasonic Positioning Device The HX11TR can be set up to operate as a ultrasonic signal receiver, ultrasonic transmitter, ultrasonic caller and ultrasonic transponder. It is small size and economical.
More informationMODEL 715AN QUADRATURE DEGREES COUNTER
MODEL 715AN QUADRATURE DEGREES COUNTER DESIGN CONCEPTS INC 707 N. Lindenwood Olathe, Kansas 66062 PHONE: (913) 782-5672 FAX: (913) 782-5766 E-MAIL : info@dcimeters.com 0411 TABLE OF CONTENTS 2. Features
More informationTEL: (203) FAX: (203) WEB:
TEL: (203)-634-3900 FAX: (203)-238-2425 EMAIL: HIGHPOWER@HIGHPOWERSECURITY.COM WEB: WWW.HIGHPOWERSECURITY.COM MODEL 3500 ONLINE DOOR CONTROLLER WITH DOOR STATUS FOR OEM & DEVELOPER APPLICATIONS HARDWARE
More informationControlLogix 7252 LDT Interface Manual Revision 1.1
Module Overview The 7252 module is a two-channel LDT interface module that resides in a Rockwell Automation ControlLogix rack. This module is capable of connecting up to two independent LDT sensors with
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationVirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual
VirtualSCADA USB to RS422/485 Isolated Converter User Manual Revision 1.01.00 Page 1 (15) Table of contents Warranty and support... 3 Product return... 3 1 About the VirtualSCADA USB to RS422/485 Converter...
More information