HYGROMETER/THERMO HYGROMETER OF SHEATH HRG40 HRG40/T HRG40L HRG40/A HRG40, /T, L CONFIGURATION HANDBOOK HRG40/A

Size: px
Start display at page:

Download "HYGROMETER/THERMO HYGROMETER OF SHEATH HRG40 HRG40/T HRG40L HRG40/A HRG40, /T, L CONFIGURATION HANDBOOK HRG40/A"

Transcription

1 HYGROMETER/THERMO HYGROMETER OF SHEATH HRG40 HRG40/T HRG40L HRG40/A HRG40, /T, L CONFIGURATION HANDBOOK HRG40/A LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P METZ CEDEX 3 Phone Fax Contact us: Commercial@Loreme.fr - Technique@Loreme.fr Date : 20/08/04 Rev 0.0a

2 TABLE OF CONTENTS DIALOGUE - TERMINAL MODE... 1) PSION Workabout... 2) PC with WINDOWS... 3) Visualization... DEVICE PRESENTATION... CONFIGURATION... 1) Method ) Menu selection ) Parameter selection ) Value acquisition... 2) Language... 3) Temperature scale... 4) Analog outputs... OFFSET MEASURE... EMC CONSIDERATION... 1) Introduction... 2) Recommendations ) Generality ) Power supply ) Inputs / Outputs... WIRING DIAGRAM... page 2 page 2 page 3 page 3 page 3 page 6 page 7 DIALOGUE - TERMINAL MODE The whole of configuration parameters can be visualized and modified by the intermediary of any system emulating a terminal and equipped with RS232 link. The dialogue and configuration parts being resident in device memory, no software or specific interface is necessary for their configuration. Two systems of terminal emulation are presented, the PSION and the PC. Different procedures are enumerated below. The link, detailed on page 6, is freely supplied on simple request. 1) PSION Workabout: To start up the PSION push the "ON" key. At the presentation, push the "MENU" key, select "SYSTEM SCREEN" mode and validate by "ENTER". Icons display: DATA CALC SHEET PROGRAM COMMS Select icon "COMMS" and validate by "ENTER", we obtain an empty screen with a flashing cursor. The PSION is in terminal mode, just link it to the device with RS232 link. The measure is displayed on screen and, to configurate, press "C" on keyboard. To quit terminal mode and switch off the PSION, push the "OFF" key. When you restart the PSION in terminal mode, it will be configured automatically and directely in terminal mode without configuring it again. 2) PC with WINDOWS: To start up terminal program: 1 - Click on "START" button, 2 - Tick off "PROGRAMS", "ACCESSORIES", and "HYPER TERMINAL", 3 - Click twice on "Hypertrm.exe" 2

3 The hereunder window is displayed. Name the connection and validate. The hereunder window appears. Choose the communication port and validate. 3) Visualization: When switching on, the device is automatically put in measure mode. The user will be able to visualize the measures on this form: 33.3 % HR/25.3 DC Humidity measure / Temperature measure 9.3 ma Humidity output value or 9.3 ma/10.3 ma Humidity output value / Temperature (HRG40 /T only). To access configuration, press "C" on keyboard and follow the configuration procedure. DEVICE PRESENTATION When quitting HyperTerminal, the following window will be diplayed. To dialog with all LOREME devices without restart all the method, click on "YES" The opposite window appears. Configure the communication parameters, 9600 bauds, no parity, 8 data bits, 1 stop, no flow control, and validate. The PC is in terminal mode, connect it to device with the RS232 link. The measure is now displayed and, to configurate, press "C" on keyboard. The purpose of this configuration handbook is to allow to become familiar with the functions supplied by the device. The HRG40 is a sheath thermo hygrometer in 2 wires technic, supplied by the current loop (the humidity information is transmitted by the device current consumption). The HRG40/T has a 2nd output insulated of the main loop for the temperature measure. The HRG40A is supplied with a 4 digits LCD display. The HRG40L is different of the standard version by a sensor with a lower accuracy. So, the session or by its short cut, it will be possible to communicate with all LOREME devices. Note: after modifying parameters of terminal mode whereas this one is in function, it is necessary to close the terminal mode and to open it again so that the new settings are effective. 3

4 CONFIGURATION The handbook explains in detail differents possibilities of configuration: Languages, temperature scales, output 1, output 2 if present. To enter in configuration mode, press the key "C" on terminal. 1) Method: At the configuration, different types of questions are asked. For each one, several answers are possible. Here is their description: 1.1) Menu selection: Example: TEMP. SCALE (Y-N) The choice is done by pressing on "Y" or "N" keys. This choice allows access to different configuration menus. 1.2) Parameter selection: Previous choice = YES: - press on "Y" => validation, choice = YES, - press on "Enter" => validation, choice = YES, - press on "N" => change, choice = NO. Previous choice = NO: - press on "N" => validation, choice = NO, - press on "Enter" => validation, choice = NO, - press on "Y" => change, choice = YES. Choices are made by pressing on "Y" or "N" keys, and validation by pressing on key corresponding to the displayed answer ("Y" for YES and "N" for NO) or by "Enter". A press on the "Enter" key without modification allows to validate previous answer. message without taking notice of the mistake. - In configuration mode, if there is no action during 2 minutes, device goes back in operating mode without taking notice of the modifications made before. - In configuration mode, if you want go back to measure mode without taking notice of modifications made before, just press "ESC" (PC) or "SHIFT + DEL" (PSION). 2) Language: The possibilities of language are: - french - english 3) Temperature scale: -Celcius or Fahrenheit degrees scale selection. -Low or high temperature scale selection. 5) Analog outputs: The device is equipped in standard with only one analog output. It can, by the /T option, receive a second output. The outputs, insulated between themselves, are independently configurable one of the other. The analog outputs configuration is composed by 2 parts: The response time allows to smooth the analog output of which the measure will be disturbed, parasitized or fluctuating. The value of this time must be includes between 0 and 60 seconds. The limitation clamp the output signal drift at 4-20mA scale for all input signal values. Only the security value goes beyond this function. 1.3) Value acquisition: Example: LOW SCALE -20 DC Two possibilities: - The validation without modification by pressing on "Enter" key, - The modification with simultaneous display followed by validation with "Enter" key. Remarks on value acquisition: - It is possible, when a mistake is made during a value acquisition, before validating it, to go back by pressing on "DEL" key. This displays again the 4

5 OFFSET MEASURE Sometimes, it may be interesting to modify measure by a simple terminal keyboard intervention. It can be used in many situations: - sensor aging, - adjustment of the measure to be adapted to the process To shift the measure, it is necessary: - to be in measure mode, - type on "+" or "-". The message "OFFSET HR" is send on the RS232 link : 42.8 % HR corrected measure value. OFFSET HR 2 indicate the actual offset value. - use keys "+" and "-" to adjust offset, - type on "Enter" to memorized the humidity offset and to go to the adjustment of temperature offset. The message "OFFSET TEMP." is send on the RS232 link : 22.8 DC corrected measure value. OFFSET TEMP. 0 indicate the actual offset value. - use the "+" and "-" keys to adjust offset, - press the "Enter" key to memorized the temperature offset. When device is not supplied or in configuration mode, offset stay active. To reset offset, it is necessary to start "OFFSET" function, put this value to zero by keys "+" and "-", then validate by "ENTER". In offset control mode, when there is no action on keys "+", "-" or "ENTER" during 2 mn, device exits of this mode without to keep adjusted offset. EMC CONSIDERATION 1) Introduction In order to insure its policy concerning EMC, based on the European directive 89/336/CE, LOREME takes into account all the standards relative to this directive as soon as the design of each device starts. All the tests made on our devices, designed to work in industrial plants, have been made regarding the EN and EN standards in order to edit a conformity certificate. It is difficult to guarantee all the results concerning EMC because tests are made in a standard and typical configuration. Results may vary when a change of configuration occurs. In order to be sure to use all the capabilities of the device, it will be necessary to respect a few rules concerning its installation. 2) Installation and utilization rules 2.1) General remarks - Installation should be made with respect to the informations given in technical documents (installation, spacing between each device...). - Utilization conditions should be in accordance with specifications of the transmitter (temperature range, protection level) specified in technical datasheet. Dust, excessive humidity, corrosives atmospheres or important heat sources should be prohibited in order to insure an optimum utilization. - Noisy environment or elements creating perturbations should be avoided. If it is possible, it will be better to install instrumentation devices separately from hi-power or commutation devices. Do not install measurement devices close to hi-power relays, thyristor groups, contactors or all electromagnetic noise generators. Do not use a portable transmitter (walkie-talkie) at less than 50 cm of the device. A 5 W transmitter may generate a field which intensity may be more than 10 V/ m at a distance near of 50 cm. 2.2) Power supply - At first, it's important to install the equipment with respect to the technical specifications given in the device's datasheet (supply voltage, frequency, tolerance of values, stability, variations...). - The power supply of the device should be issued from a supply system using section switches and fuses made for instrumentation devices, and the supply line should be as direct as possible from section switch. Don't use this power supply for relays, contactors or valves command. 5

6 - An isolating transformer, with its screen shorted to ground may be necessary if the supply circuit is made noisy with commutation of thyristors, relays, motors, speed variators... - It's important that the installation hast to be connected to ground. The voltage between neutral and earth must be less than 1 V and the resistance must be less than 6 Ohms. - If the equipment has been installed near hi-frequency generators or arc welding installations, it may be useful to install adequat filters on the mains supply. TERMINAL - DEVICE LINK 2.3 ) Inputs / Outputs - In a noisy environment, it will be better to use shielded and twisted wires. The ground connection will be made at a single end of the wire. - I/O lines should be well separated from supply wires in order to avoid coupling between these wires. - Data wires length should be as short as possible. 6

7 WIRING DIAGRAM DIMENSIONS 117 mm 53 mm Tête DAAD-C Plexiglass LOAD 4 / 20 ma PE 16 Pe 16 TEMPERATURE MEASURE LOOP POWER SUPPLY (OPTION HRG40/T) / 20 ma + - LOAD HUMIDITY MEASURE LOOP POWER SUPPLY H24 1/2" Gaz cylindrique 87 mm Ø mm 1/2" Gaz cylindrique Ø13,5 mm 100 mm 2.3 mm G1/8" Elément Interchangeable 25 mm Filtre Legris 0674 SILENCIEUX PLASTIQUE MALE BSP CYL G1/8" Male 3 pins connector RS232 7

PROGRAMMABLE NUMERIC CONVERTER CNL 23 CONFIGURATION HANDBOOK

PROGRAMMABLE NUMERIC CONVERTER CNL 23 CONFIGURATION HANDBOOK PROGRAMMABLE NUMERIC CONVERTER CNL 23 CONFIGURATION HANDBOOK LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Telephone 03.87.76.32.51 - Fax 03.87.76.32.52 Contact: Commercial@Loreme.fr

More information

PROGRAMMABLE NUMERIC CONVERTER CNL 45 CNL 45L CONFIGURATION AND UTILISATION HANDBOOK

PROGRAMMABLE NUMERIC CONVERTER CNL 45 CNL 45L CONFIGURATION AND UTILISATION HANDBOOK PROGRAMMABLE NUMERIC CONVERTER CNL 45 CNL 45L ------------------------- CONFIGURATION AND UTILISATION HANDBOOK LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Telephone

More information

PROGRAMMABLE NUMERIC CONVERTER CPL 23 CONFIGURATION HANDBOOK

PROGRAMMABLE NUMERIC CONVERTER CPL 23 CONFIGURATION HANDBOOK PROGRAMMALE NUMERIC CONVERTER CPL 23 CONFIGURATION HANDOOK LOREME 12, rue des Potiers d'etain Actipole ORNY.P. 35014 57071 METZ CEDEX 3 Telephone 03.87.76.32.51 Fax 03.87.76.32.52 Contact: Commercial@Loreme.fr

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK Multi-channels temperature converter with LCD display CONFIGURATION HANDBOOK TEMAX105LCD LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 Contact :

More information

PROGRAMMABLE INDICATOR

PROGRAMMABLE INDICATOR PROGRAMMABLE INDICATOR CONFIGURATION AND UTILIZATION INL50L, L/S, L/I, L5 95000L, L/S, L/I, L5 INL50LI8 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 phone 03.87.76.32.51

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK PROTECTION RELAY / THRESHOLD RELAY CONFIGURATION HANDBOOK DSL35L LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 - Telefax 03.87.76.32.52 Contact

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK PROGRAMMABLE DC OVER CURRENT PROTECTION RELAY CONFIGURATION HANDBOOK RPS23 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 - Telefax 03.87.76.32.52

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK THRESHOLD RELAY FOR RESISTIVE LEVEL SENSOR CONFIGURATION HANDBOOK RNL35L LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 Contact : Commercial@Loreme.fr

More information

CONFIGURATION HANDBOOK BGL144

CONFIGURATION HANDBOOK BGL144 PROGRAMMABLE BARGRAPH CONFIGURATION HANDBOOK BGL144 BGL172 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 - Telefax 03.87.76.32.52 Contact : Commercial@Loreme.fr

More information

HARDENED ROOM SENSOR USER MANUAL SAD120 CPO55 E 1

HARDENED ROOM SENSOR USER MANUAL SAD120 CPO55 E 1 HARDENED ROOM SENSOR USER MANUAL SAD120 CPO55 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 Contact : Commercial@Loreme.fr - Technique@Loreme.fr

More information

Ethernet / RS485 Gateway

Ethernet / RS485 Gateway Ethernet / RS485 Gateway CONFIGURATION HANDBOOK ICL70 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 Contact : Commercial@Loreme.fr - Technique@Loreme.fr

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK MINIATURE DIGITAL INDICATOR / CHASSIS THERMOSTAT CONFIGURATION HANDBOOK 94000 94000L LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 Contact : Commercial@Loreme.fr

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK CONVERTER FOR ABSOLUTE SSI ENCODER CONFIGURATION HANDBOOK CNL35 SSI LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 - Telefax 03.87.76.32.52 Contact

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK Binary Gray BCD to 4-20mA or 0-10V converter for parallel outputs encoders CONFIGURATION HANDBOOK CNA105 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK 125 khz RFID reader with Ethernet MODBUS-TCP link CONFIGURATION HANDBOOK RFID90 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 - Telefax 03.87.76.32.52

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK Threshold relay for direct or alternative current. Current monitoring relay. CONFIGURATION HANDBOOK DSL35LCC LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK Analog to digital converter 4-20 ma to BCD - GRAY - BINARY CONFIGURATION HANDBOOK CAN105 CAN105BCD LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK AC & DC TRMS current and voltage transducer Wattmeter, Voltmeter, Ammeter,... CONFIGURATION HANDBOOK CPL35 CPL35L LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone

More information

RPL23 RPL23uC RPL23peak RPL23Ho

RPL23 RPL23uC RPL23peak RPL23Ho PROTECTION MONITORING RELAY FOR AC & DC CURRENT PHASE CONTROL RELAY CONFIGURATION HANDBOOK RPL23 RPL23uC RPL23peak RPL23Ho LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK PROGRAMMABLE MEASURE CONVERTER CONFIGURATION HANDBOOK CNL35L LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 Contact : Commercial@Loreme.fr - Technique@Loreme.fr

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK LED BARGRAPH WITH CIRCULAR STRIP LIGHT CONFIGURATION HANDBOOK BGCL96 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 - Telefax 03.87.76.32.52 Contact

More information

Commissioning and safety manual SIL2

Commissioning and safety manual SIL2 Commissioning and safety manual CAL23MA/S2 SIL2 SIL3 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Téléphone 03.87.76.32.51 - Télécopie 03.87.76.32.52 Nous contacter:

More information

UTILIZATION AND CONFIGURATION

UTILIZATION AND CONFIGURATION Measurement unit for distribution panel (DPM) Wattmeter, Energy meter for multi electrical feeders UTILIZATION AND CONFIGURATION CPL165 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071

More information

CONFIGURATION HANDBOOK IPL36 IPL36L

CONFIGURATION HANDBOOK IPL36 IPL36L AC & DC true RMS panel Wattmeter, Voltmeter, Ammeter, Frequency meter CONFIGURATION HANDBOOK IPL36 IPL36L LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

Thermocouple Input Module Product Specifications and Installation Data

Thermocouple Input Module Product Specifications and Installation Data Thermocouple Input Module Product Specifications and Installation Data 1 DESCRIPTION The Horner APG Thermocouple Input Modules allow thermocouple temperature sensors to be directly connected to the PLC

More information

Operation Manual Series W-500

Operation Manual Series W-500 Operation Manual Series W-500 Table of Content 1 Safety information... 2 1.1 Place of application of the unit... 2 1.2 Instructions for installation... 3 2 Start-up and adjustment of controller 4 3 General

More information

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2. Section 1.0 Introduction 1.1 Important user information... 2 1.2 General... 2 1.3 Manual description...2 Contents Section 2.0 Specification 2.1 General technical data...3 2.2 Dimensions...3 Section 3.0

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

HI-POT TESTER. User s Manual

HI-POT TESTER. User s Manual HI-POT TESTER 7620 User s Manual Contents 1. Before Use... 1.1Electric Shock Avoidance... 4 1.2 Grounding... 4 1.3 AC Power Supply... 4 1.4 Connecting Test Leads... 4 1.5 Warm Up... 4 1.6 External Control...

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

Precision thermometer Model CTR5000

Precision thermometer Model CTR5000 Calibration technology Precision thermometer Model CTR5000 WIKA data sheet CT 60.20 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

HZS Internal Controller Expansion

HZS Internal Controller Expansion HZS 532-2 Internal Controller Expansion Date of creation: 19.05.2016 Version date: 19.05.2016 Article number: 05-895-532-2E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax:

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

1450 First Ave. Page 1 of 11 Chippewa Falls, WI (800) or (715) Fax: (715)

1450 First Ave. Page 1 of 11 Chippewa Falls, WI (800) or (715) Fax: (715) 1450 First Ave. Page 1 of 11 Model DHM200 User Manual 1450 First Ave. Page 2 of 11 Warranty This product is fully warranted against defective materials and/or workmanship for a period of one year after

More information

CHAPTER 1. Introduction Introduction 3

CHAPTER 1. Introduction Introduction 3 Technical & User Manual Weight Indicator: SMIT-3015 Manufactured By: Samyak Instrumentation Pvt.Ltd. F-4, Memnagar Complex, Opp.Petrol Pump, Memnagar Village, Ahmedabad, India-380052. Phone: +91-79-27495500/5600,

More information

COUNTIS Ci Notice d utilisation GB Operating instructions Bedienungsanleitung NL Gebruiksaanwijzing

COUNTIS Ci Notice d utilisation GB Operating instructions Bedienungsanleitung NL Gebruiksaanwijzing COUNTIS Ci I F Notice d utilisation GB Operating instructions D Bedienungsanleitung NL Gebruiksaanwijzing Istruzioni per l uso SP Instrucciones de servicio P Manual de instruções PRELIMINARY OPERATIONS

More information

SIMOREG 6RA70 DC MASTER SIMOREG CM

SIMOREG 6RA70 DC MASTER SIMOREG CM SIMOREG RA70 DC MASTER /2 Application /2 Design /3 Technical Data /3 Standards /4 Block diagram / Options Siemens DA 21.1 200 /1 SIMOREG RA70 DC MASTER Application An important application for the converter

More information

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E Table of contents 1. INTRODUCTION...1 2. HARDWARE DESCRIPTION...2 3. INSTALLATION...6 4. CONNECTION...8 5. USER SAFETY AND PROTECTION OF THE EQUIPMENT...11

More information

Internal Buffer/Boiler Module HZS 534

Internal Buffer/Boiler Module HZS 534 INTERNAL BUFFER/BOILER MODULE HZS 534 Internal Buffer/Boiler Module HZS 534 30.11.2015 Page 1 INTERNAL BUFFER-/BOILERMODUL HZS 534 Configuration HZS 534 internal buffer/boiler module for the heating controller

More information

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast

More information

COUNTIS ATv2/ATiv2 GB

COUNTIS ATv2/ATiv2 GB COUNTIS ATv/ATiv GB Operating instructions Industrial Switching & Protection Systems SOCOMEC - Ref. : D ENGLISH GB Contents PRELIMINARY OPERATIONS GENERAL INFORMATION PRESENTATION INSTALLATION CONFIGURATION

More information

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display UC102 Communicative heating controller Summary UC102 is a communicative room heating controller with two inputs and one PWM output for control of a radiator or electrical heater. It can work autonomously,

More information

Communication module to connect M-bus devices to POL6xx.xxx controllers.

Communication module to connect M-bus devices to POL6xx.xxx controllers. s 3 936 Climatix TM Climatix communication M-Bus module POL907.00/xxx Communication module to connect M-bus devices to POL6xx.xxx controllers. The POL907.00/xxx communication module offers the following

More information

Contents. Temperature & Process Measurement Indicators Setup Guide

Contents. Temperature & Process Measurement Indicators Setup Guide Contents Introduction... 2 Installation... 3 Connections... 5 Connecting the Sensor... 6 Powering the Instrument... 7 Operator Functions... 8 The Setup Menus... 9 Configuration Menu Map... 12 Menu Options...

More information

User s manual. Programmable panel meter IPD

User s manual. Programmable panel meter IPD User s manual Programmable panel meter IPD Assembly Wall assembly: +0,5 +0,2 Window of 46 x 91 mm (2.5" x 3.5" ) Made with ABS (UL94-HB) -0-0 General cares in the installation The equipments must not be

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is

More information

SCXI -1313A Terminal Block

SCXI -1313A Terminal Block INSTALLATION GUIDE SCXI -1313A Terminal Block Conventions This guide describes how to install and use the SCXI-1313A terminal block with an SCXI-1125 module. The SCXI-1313A terminal block is shielded and

More information

NMEA Multiplexer Owner s Handbook. Document Number: Date: February 2005

NMEA Multiplexer Owner s Handbook. Document Number: Date: February 2005 NMEA Multiplexer Owner s Handbook Document Number: 81250-1 Date: February 2005 Copyright Raymarine (UK) Ltd 2005 i Preface Congratulations on having bought a Raymarine NMEA Multiplexer. This enables you

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

MCX06C Programmable controller

MCX06C Programmable controller Data sheet MCX06C Programmable controller MCX06C is an electronic controller that holds all the typical functionalities of MCX controllers in the 32x74 mm standard size: programmability connection to the

More information

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation: DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated

More information

Electronic pressure switch with display Model PSD-4

Electronic pressure switch with display Model PSD-4 Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine

More information

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,

More information

KOBOLD PDA Series Digital Pressure Transmitter

KOBOLD PDA Series Digital Pressure Transmitter KOBOLD PDA Series Digital Pressure Transmitter PDA-153 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com

More information

Flow measurement with sensors BZS25 at working temperatures up to +500 C optional with integrated and configurable transducer UFA

Flow measurement with sensors BZS25 at working temperatures up to +500 C optional with integrated and configurable transducer UFA Flow measurement with sensors BZS25 at working temperatures up to +500 C optional with integrated and configurable transducer UFA Drawing 4 Measurable variable standard flow velocity v [m/s] in air/gases

More information

Zenith DS9000 Dispensing System

Zenith DS9000 Dispensing System Page Date: 04/2009 Zenith DS9000 Dispensing System Installation & Operation Manual Page 2 Table of Content Introduction... 3 Control Specification... 4 Wiring Diagram... 5 Wiring Instructions... 6 Field

More information

LDCL DIGITAL CONTROLLER OPERATING MANUAL

LDCL DIGITAL CONTROLLER OPERATING MANUAL This manual contains important safety informations about installation and use of this equipment. Ignoring this informations could result in injuries or damages. It is strictly forbidden to use this equipment

More information

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions. Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64

More information

ASTAT XB/XBm Remote Operator

ASTAT XB/XBm Remote Operator ASTAT XB/XBm Remote Operator User Manual 1 Introduction 1.1 Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery

More information

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement TP32MTT.03 [ GB ] Probes for soil thermal profile measurement [ GB ] [ GB ] Description Temperature measurement at 7 levels (TP32MTT.03) or 6 levels () In accordance with the requirements of the World

More information

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O DATASHEET NI REM-11115 Analog Output Module for Remote I/O Four voltage output ranges to choose from (0 V to 10V, ±10V, 0 V to 5 V, and ±5V) Two current output ranges to choose from (0 ma to 20mA, 4 ma

More information

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4. CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. 4. Relays Power supply 2. Relays 8. Universal Inputs/ Process Bus (KNX) RS485 (Modbus) Tool (USB) Ethernet Tool (USB)/

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097 Tele fax : +91-44-24581758,Mobil

More information

InCos-P Pressure sensor 20 Pa Pa

InCos-P Pressure sensor 20 Pa Pa InCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue Compact. Easy installation. Universal. Cost effective. Safe.

More information

Resistance measuring module

Resistance measuring module s 8 176 8176P01 TX-I/O Resistance measuring module TXM1.8P 8 inputs with LED signal / fault display. 8 resistance measuring inputs with individual configuration of resistance or temperature measurement.

More information

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual The Flomatic FDHC-100 is a high performance Digital positioner intended to control AC actuators, providing 450 points of resolution with quarter turn actuators ranging from 2 sec to 120 sec and rated for

More information

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers OEM CLIMATIX TM Room unit QAA822 with2- wire interface For use with Climatix controllers Remote control of air conditioning unit Mandík Measurement of the room temperature Buttons for starting, setting

More information

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER. 3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, 16000 Data logger no., RS232 THERMOMETER Model : YK-2005TM TABLE OF CONTENTS 1. FEATURES...1 2. SPECIFICATIONS... 2 2-1 General

More information

Switched Mode Power Supply Operating manual PAP800

Switched Mode Power Supply Operating manual PAP800 Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced

More information

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137 MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137 Revision History Page 1 of 11 Date ECN Rev Description By 09/01/10 EC34869 A Initial Release D. Stahl 07/14/11 EC39745 B Updated

More information

1. Introduction. 2. Installation MODBUS INTERFACE

1. Introduction. 2. Installation MODBUS INTERFACE 5551.C 8473.C MODBUS INTERFACE PIM-MB-1 Modbus Interface 1. Introduction AuCom soft starters can be controlled and monitored across an RS485 serial communication network using the Modbus RTU and AP ASCII

More information

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual LOGGER S0541 Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual Instruction Manual for use of S0541 logger Instrument is designed for measurement and record of temperature

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission

More information

E-Key16. Manual. English MA

E-Key16. Manual. English MA MA00644 2002-11 E-Key16 Manual English Foreword Manual for E-Key16 Foreword This manual describes installation and functions of the extended function keyboard E-Key16. All configuration of the extended

More information

KOBOLD TDA Series Digital Temperature Transmitter

KOBOLD TDA Series Digital Temperature Transmitter KOBOLD TDA Series Digital Temperature Transmitter TDA-15 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com

More information

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications 3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for

More information

F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide

F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide MODBUS FLOW AND ENERGY MEASUREMENT F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 0725-2

More information

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY USER MANUAL Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct

More information

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400

More information

02/11/2015

02/11/2015 DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function MXIO Compact I/O module Summary The MXIO multiple I/O compact module is a microprocessor-controlled, communicative module with the I/O mix optimized for larger HVAC control applications. The module uses

More information

Compact data logger offering best-in-class noise resistance and communication function

Compact data logger offering best-in-class noise resistance and communication function T M Portable Data Station XL100 Series Compact data logger offering best-in-class noise resistance and communication function A world s first in measuring instruments! To obtain IPv6 Ready Logo Phase-1

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS

955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS Series ebrik INSTALLATION MANUAL LINEAR DISPLACEMENT TRANSDUCERS ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS Introduction The is an accurate programmable, auto-tuning, noncontact, linear

More information

MC1000 Multi-Function Calibrator

MC1000 Multi-Function Calibrator MC1000 Multi-Function Calibrator Table of Contents 1. Introduction 1.1 Customer Service................1 1.2 Standard Equipment..............1 1.3 Safety Information................2 2. Quick Start Instructions

More information

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual FG-7000T Digital Torque Gauge Operation Manual SHIMPO INSTRUMENTS Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020 USER MANUAL MULTI COLOR MODEL : ARC2020 ACCSYS ELECTRONICS 140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD, GERUGAMBAKKAM, CHENNAI - 600122 Tel: 044 60505599 / 60505511 E-mail : sales@accsyselectronics.com

More information

Trend-1 Vibration Data Logger. User Manual

Trend-1 Vibration Data Logger. User Manual Trend-1 Vibration Data Logger User Manual Copyright College of Engineering-University of Basrah 2013 1 1. General Specifications 1.1 Features Thank you for being interested in purchasing Trend-1 Vibration

More information

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

VIBRATION METER Model : VB-8213

VIBRATION METER Model : VB-8213 Acceleration/Velocity/Displacement RMS/Peak/Max. Hold, Metric & Imperial unit VIBRATION METER Model : VB-8213 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision

More information

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no. METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no. 20 751 979 Distributor: Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit Product data sheet 94.040 EY-RU 341...346: Room operating unit, ecounit341...346 How energy efficiency is improved Individual setting of occupancy and absence as well as a room setpoint correction and

More information