EU Declaration of Conformity
|
|
- Jade Allison
- 5 years ago
- Views:
Transcription
1 Product: Name and address of the manufacturer: Rockwell Automation Inc. 101 South nd Street Milwaukee, WI 0 U.S.A. EU Declaration of onformity IE 0A Frame ircuit Breakers and Accessories Name and address of the authorised representative: Rockwell Automation B.V. Rivium Promenade LM apelle aan den Ijssel The Netherlands This declaration of conformity is issued under the sole responsibility of the manufacturer. Object of the declaration: Allen-Bradley 10U-D Series and Accessories (reference the attached list of catalogue numbers) The object of the declaration described above is in conformity with the relevant Union harmonisation legislation: 01//EU Low Voltage Directive (LVD) 011//EU RoHS Directive (RoHS) References to the relevant harmonised standards used or references to the other technical specifications in relation to which conformity is declared: EN 097-:00+A1:009+A:01 EN :00+A1:009 EN 081:01 Low-voltage switchgear and controlgear Part : ircuit-breakers Low-voltage switchgear and controlgear Part -1: ontrol circuit devices and switching elements Electromechanical control circuit devices Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Signed for and on behalf of the above named manufacturer: Place and date of issue: Aarau, Switzerland 08-May-017 Name, function: Signature: Daniel Baumann, Manager Product ertification Engineering Document ontrol Number: P-08-F-EN (10U-T001B-EN-E) 1 /
2 atalogue number Series 1 Description Directive LVD RoHS 10U IE 0 A Frame ircuit Breakers per Nomenclature Yes Yes Accessories 10M Auxiliary ontact Blocks per Nomenclature Yes Yes 10M Trip ontact Blocks per Nomenclature Yes Yes 10M Left Side Mounting Trip Function per Nomenclature Yes Yes 10U D WTE Feeder Terminal, for compact busbars Yes Yes 10U D W Three Phase ompact Busbar (mm, connections) 10U D W Three Phase ompact Busbar (mm, connections) 10U D W Three Phase ompact Busbar (mm, connections) N/R Yes 10U D W Three Phase ompact Busbar (mm, connections) 10U D PE EO onnecting Module, for combination 10U D ircuit N/R Yes Breaker to ontactor 10U D PF Flexible Wire Module, for combination 10U D ircuit N/R Yes Breaker to ontactor 10M KN1 Lockable Twist Knob (black) N/R Yes 10M KRY1 Lockable Twist Knob (red/yellow) N/R Yes 10M M Locking Attachment N/R Yes 198 SHB Lockable Handle (black) N/R Yes 198 SHRY Lockable Handle (red/yellow) N/R Yes 10M DN Door oupling Handle (black) N/R Yes 10M DRY Door oupling Handle (red/yellow) N/R Yes 10M SB Rotary Disconnect Handle (black) N/R Yes 10M SY Rotary Disconnect Handle (red/yellow) N/R Yes 10M DS Extension Shaft for Door oupling Handle N/R Yes 10M DSL Extension Shaft for Door oupling Handle N/R Yes 10M S1 Extension Shaft for Rotary Disconnect Handle N/R Yes 10M S Extension Shaft for Rotary Disconnect Handle N/R Yes 10M N Mounting Adapter N/R Yes 10M SHS Shaft Support N/R Yes 1) If no series number is given, then all series are covered. ) Yes = Product is certified to this directive. N/R = This directive is not required for this product. Document ontrol Number: P-08-F-EN (10U-T001B-EN-E) /
3 MODEL NOMENLATURE: IE 0 A Frame ircuit Breakers atalogue Number Explanation 10U U Base atalogue Number of IE 0 A Frame ircuit Breaker Frame / urrent Rating D 0 A frame Breaking apacity Type High breaking capacity Protection Type D Fixed thermal / fixed magnetic Number of Poles poles poles 7 A0 B10 B0 B0 B0 B0 B0 B No suffix MT M urrent Rating 0.A 1A A A A A A 8A 10A 1A 1A 0A A 0A Options (may be combined with ' ') No option Standard Bus Bar mount (top feed) ompact Bus Bar mount (top feed) Document ontrol Number: P-08-F-EN (10U-T001B-EN-E) /
4 A.) Auxiliary ontact Blocks Accessories atalogue Number Explanation 10M M Base atalogue Number of Auxiliary ontact Block No suffix letter R Screw Terminals Spring Force Terminals For ircuit Breaker Type AFA ASA Two digits 10M, 10M D, 10M F, 10U D Mounting Position Front mounted Right side mounted (with Screw Terminals only) ontact onfiguration of Auxiliary ontacts Second digit indicates number of N.. contacts B.) Trip ontact Blocks 10M M Base atalogue Number of Trip ontact Block No suffix letter R Screw Terminals Spring Force Terminals For ircuit Breaker Type AFA ASA No suffix Letter R, followed by two digits Letter A or M, followed by two digits 10M, 10M D, 10M F, 10U D Mounting Position Front mounted Right Side mounted (with Screw Terminals only) ontact onfiguration of Auxiliary ontacts No Auxiliary ontact is provided Second digit indicates number of N.. contacts ontact onfiguration of Auxiliary ontacts Second digit indicates number of N.. contacts Document ontrol Number: P-08-F-EN (10U-T001B-EN-E) /
5 Accessories atalogue Number Explanation (continued).) Left Side Mounting Trip Function 10M M Base atalogue Number of Left Side Mounting Trip Function No suffix letter Screw Terminals For ircuit Breaker Type 10M, 10M D, 10M F, 10U D Trip Function U UX SN Undervoltage Undervoltage (Series B and later) Shunt (Series B and later) ontrol Voltage ode (indicates voltage and frequency) One or two letters A voltages (in the range of 00V0Hz or 1V0Hz/80V0Hz) D voltages (in the range of 9 80VD). Two letter code starting with Z Document ontrol Number: P-08-F-EN (10U-T001B-EN-E) /
EU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation Inc. 101 South nd Street Milwaukee, WI 5304 U.S.A. EU Declaration of Conformity IEC Contactors, Reversing Contactors and Accessories Name
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation Inc. 0 South nd Street Milwaukee, WI 504 U.S.A. EU Declaration of Conformity IEC Contactors, Safety Contactors, Reversing Contactors,
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell utomation, Inc. 0 South nd Street Milwaukee, WI 04 U.S.. U Declaration of Conformity IC Switches and Switch-Disconnectors, 40 and ccessories Name
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell utomation Inc. 101 South nd Street Milwaukee, WI 504 U.S.. EU Declaration of Conformity IEC Control Relays, Safety Control Relays and ccessories
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell utomation Inc. 0 South nd Street Milwaukee, WI 50 U.S.. U Declaration of Conformity IC Switch-Disconnectors, 00 and ccessories Name and address of
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell utomation Inc. 101 South nd Street Milwaukee, WI 504 U.S.. EU Declaration of Conformity IEC Contactors, Safety Contactors, Reversing Contactors,
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Sprecher + Schuh 15910 International Plaza Drive Houston, TX 770 U.S.A. EU Declaration of Conformity IEC Contactors, Safety Contactors, Reversing Contactors,
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell utomation G Industriestrasse 0 CH-5000 arau Switzerland U Declaration of Conformity IC Switch-Disconnectors, 00 and ccessories Name and address of
More information140M C 2 E A63 KN CC GJ
Motor Protection Circuit Breakers Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection;
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: This is to certify that representative samples of SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY MOTOR CONTROLLERS, MANUAL (See following page for additional information.)
More information140M C 2 N A63 KN CC GJ
Motor Circuit Protectors Product Overview/Catalog Number Explanation Product Line Overview C-Frame D-Frame F-Frame H-Frame J-Frame L-Frame N-Frame Max. Current I e A A A 00 A 0 A 00 A 00 A Current Rating
More informationEU Declaration of Conformity
EU Declaration of Conformity Document No. Product: Miniature circuit breakers, Residual current circuit breakers and Isolating switches, DIN series Manufacturer: MITSUBISHI ELECTRIC INDIA PRIVATE LIMITED
More informationEC Declaration of Conformity
The undersigned, representing the manufacturer Rockwell Automation uchserstr. 7 CH-5000 Aarau, Switzerland herewith declare that the Products Product identification (brand and catalogue number/part number):
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationProcess Sealed Rotaries
New Product N-0 NR0 Series Process Sealed Rotaries Subminiature Rotaries with Positive, Distinctive Detent 07-07-7 Series NR0 Subminiature Process Sealed Rotaries General Specifications Electrical apacity
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More informationGo to:
System PKZ 0 ectors 08/019 Clip plate Standard version Short version C-PKZ0 072900 C-PKZ0-K 206740 One of the clip plates is always necessary when combining a PKZM0 manual motor prr and a S(E)00 magnetic
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ Catalog Number ➍➏➑➒ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More information3RV1 Circuit-Breakers
SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a
More informationMolded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...
Circuit Breakers, 09/054 Moeller Electric Corporation Auxiliary Contacts for Type Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic N.O. N.C. Standard auxiliary
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationMolded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-...
Circuit Breakers, Disconnect Switches, Molded Case Switches 09/064 Moeller Electric Corporation Auxiliary Contacts for. Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationMotor protection circuit breakers
Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability
More informationWiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3
Wiring diagrams Content Information for reading and graphic symbols... 5/2 Wiring diagrams of the circuit-breakers... 5/3 Electrical accessories... 5/4 5/1 Information for reading and graphic symbols State
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~
More informationMolded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-...
Circuit Breakers, 09/074 Moeller Electric Corporation Auxiliary Contacts for Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic device N.O. N.C. Standard auxiliary
More informationOperating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...
Safety sensor BNS 0 Disassembly and disposal. Disassembly..... Disposal... 7 EU Declaration of conformity Operating instructions.............pages to Original x.000 / 09.08 / v.a. - 08- / Q / 08-09- /
More informationOperating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...
6 Disassembly and disposal 6.1 Disassembly....6 6.2 Disposal...6 7 EU Declaration of conformity Operating instructions.............pages 1 to 8 Original x.000 / 09.2017 / v.a. - 101178533- / I / 2017-08-31
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationSiemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY
Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0
More informationOperating instructions Hinge safety switch TV.S 335 TV.S About this document. Content
1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationJtec 10kA Miniature Circuit Breaker
Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide
More informationSeries. C Series Quick Start Guide. English. One Printer for your Entire Enterprise.
C Series Quick Start Guide Series Compact Industrial Printers English One Printer for your Entire Enterprise. CognitiveTPG, LLC 950 Danby Road, Suite 200, Ithaca, NY 14850 Toll Free: 800-732-8950 Phone:
More informationPowerFlex 700L Liquid-to-Liquid Heat Exchanger Control Board Replacement
Installation Instructions PowerFlex 700L Liquid-to-Liquid Heat Exchanger Replacement ATTENTION: To avoid an electric shock hazard and prevent thermal damage, ensure that all power to the drive power module
More informationOperating instructions Safety sensor BNS About this document. Content
Safety sensor BNS 0. About this document Operating instructions.............pages to 6 Original. Function This operating instructions manual provides all the information you need for the mounting, set-up
More informationComplete UL/CSA Disconnect Switch Kits
Product Selection Complete UL/CSA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA handle, auxiliary contacts, and padlock attachment.
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationOperating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...
8 Appendix 8.1 Wiring examples...3 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126006- / H / 2017-11-17 / AE-Nr. 8410 Content 1 About
More informationPowerFlex 40 Configured AC Drives
Installation Instructions PowerFlex 0 onfigured A Drives atalog Numbers B Important User Information Read this document and the documents listed in the additional resources section about installation,
More informationMotor Control Products Selection Guide
MKING MODERN LIVING POSSIBLE Motor Control Products Selection Guide Contactors, Relays, and Circuit Breakers www.danfoss.com/ia c o n t e n t s Minicontactors CI 5 Thermal Overload Relays TI 9C for Minicontactors
More informationOperating instructions Safe AS-i input module ASIM-C-M About this document. Content
7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10
More informationOperating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...
7 ppendix 7.1 Wiring example...5 8 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / Januar 2017 / v.. - 101196069- / F / 2017-01-12 / E-Nr. 5813 Content 1 bout
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationOperating instructions Safety-monitoring module AES 1235 AES About this document. Content
8 Appendix 8.1 Wiring examples...3 8.2 Integral System Diagnostics (ISD)....4 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101172890-
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A
Fuse protection The solution for > Motor load break. > Protection of industrial cabinet. > Electrical distribution. ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More information3RP, 7PV Timing Relays
3RP, PV Timing Relays Overview Standards The timing relays comply with: EN 6021-3-3 "Environmental conditions" EN 61812-1/DIN VDE 0435 Part 2021 "Solid-state relays, timing relays" EN 61000-6-2 and EN
More informationMEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety
MEDIUM VOLTAGE PRODUCTS UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety 2 UNISEC AIR-INSULATED MEDIUM VOLTAGE SECONDARY DISTRIBUTION SWITCHGEAR Operator
More information(Cat. No P4 and 1777-P4)
(Cat. No. 1772-P4 and 1777-P4) Product Data The 1772-P4 and 1777-P4 power supplies provide DC power for the logic circuits in PLC-2 family programmable controllers. These power supplies can accept a power
More informationGuardmaster 440G-LZ Guard Locking Switch User Manual
Guardmaster 440G-LZ Guard Locking Switch User Manual Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines
More informationCERTIFICATE OF COMPLIANCE
Issued to: SIEMENS AG LOW VOLTAGE SIEMENSSTRASSE 10 93055 REGENSBURG GERMANY This is to certify that representative samples of CIRCUIT BREAKERS, MOLDED CASE AND CIRCUIT- BREAKER ENCLOSURES See Addendum
More information4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...
.3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual
More informationOverload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview
Overload Relays Siemens AG 2009 Overview 1 2 2 (1)Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters, these connecting
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationThermal-Magnetic Circuit Breaker 2216-S
Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional
More informationESS20 Electronic Circuit Breaker
ESS20 Electronic Circuit Breaker How does (selective) protection of loads work with DC 24 V power distribution systems? E-T-A's latest product. The 24V power supply Transformer or switch-mode? The well-proven
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationOperating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...
7 ppendix 7.1 Wiring example...5 8 Declaration of conformity 8.1 EC Declaration of conformity...6 Operating instructions.............pages 1 to 6 Translation of the original operating instructions x.000
More informationReferences. References. Rating (A) Référence
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle
More informationDescription. Installation. Power supply
Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of
More informationSENTRON 3VL Molded Case Circuit Breakers
Siemens AG SENTRON VL Molded Case Circuit Breakers Switching, Protection, Measuring and Monitoring Devices For the operating range from A to 00 A, the molded case circuit breaker ensures the optimum overload
More informationThermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction
Thermal-Magnetic / Magnetic Only Molded ase ircuit reakers Introduction Table 8: reakdown of Typical atalog Number L 3 6 050 V 2100 reaker amily Y - mpere rame - 100 mpere rame K - 250 mpere rame L - 400
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationMAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure
MKING MODERN LIVING POSSIBLE CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M - 100 Technical brochure 2 IC.PD.C00.5.02-520B3595 Danfoss /S (R-MC/mr) 08-2009 Contents Page Circuit Breakers/
More informationThe right solution for every home
Domae Household switchboards The right solution for every home Household guide 2002 Building a New Electric World. Household switchboards Domae The right solution for every home Household guide 2002 Building
More informationRelays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection
Q Series Q Series PB elays Switches & Pilot Lights Display Lights IDE Q relays are low-profile, PB relays that provide quality within a compact package. Size equals value. Q relays are small, yet maintain
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options
More informationROMEO. Joystick. OptiOns. FEatuREs. CERtiFiCatiOns
Joystick ROMEO Sturdy and reliable joystick for harsh environments and situations. Materials, technical solutions and sizing of critical components studied to guarantee mechanical resistance and long life,
More informationFUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC
Fuse protection The solution for > Live maintenance of speed drives supplied by a common DC bus > Live maintenance of PV inverters connected in parallel on a same circuit fuser-lm_2_a Strong points > Compact
More informationTruPortal Output Expansion Board Quick Reference
TruPortal Output Expansion Board Quick Reference en-us Packing List Introduction A TruPortal system can be expanded by adding an Input/Output Expansion module (TP-ADD-IO-BRD) that consists of: One TruPortal
More informationsirius Switching. Protecting. Starting. SIRIUS Product Overview
sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar
More informationTruPortal Dual Door Interface Module Quick Reference
TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers
More information(Cat. No P1) Installation Data
(Cat. No. 1771-P1) Installation Data Use this publication to install a 1771-P1 system power supply. You perform these tasks: prepare to install the power supply - install batteries into the battery pack
More informationCircuit Breakers, Type CTI 25M, CTI 45MB, CTI 100
MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit
More informationTechnical Guide. Safety Applications. For Immediate Delivery call KMParts.com at (866) Building Automation. Industrial Automation
tra Combinations Building Automation Industrial Automation Systems Technical Guide Safety Applications Ulrich Trapp Bildgrösse 0 x 118,5 mm 2 Logo 17 x 17 mm Think future. Switch to green. Risk assessment
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.4 Contents Description Page Product Description............................. 677 Standards and Certifications...................... 677 Product Selection..............................
More informationCI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100
MKING MODERN LIVING POSSIBLE Technical brochure CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit- and overload protection of motor applications
More informationOperating instructions Position switches EX-Z/T G/D. 1. About this document. Content
6 Disassembly and disposal 6.1 Disassembly....5 6.2 Disposal...5 7 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 08.2018 / v.a. - 101185191- / N / 2018-08-15
More informationBlock I/O Cat. No IOBA and -IOBB Series B User Manual
User Manual Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary
More informationProtect Circuit Protection
Circuit Protection Product Catalogue 2018 Protect Circuit Protection Deta s new range of domestic Circuit Protection provides a high quality and cost effective solution, perfect for both new build and
More informationDriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.
DriveGuard Safe-Off Option for PowerFlex 70 AC Drives User Manual www.abpowerflex.com Important User Information Solid state equipment has operational characteristics differing from those of electromechanical
More informationFK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK FK Protection. Trip Unit. Rated Current (A) FK800 FK1250 FK1600
K rame reaking capacities Icu 400/45V in k eff. Type V K K2 K600 N H 80 80 80 L 00 00 Protection Trip Unit K K2 K600 Rated urrent () 60 000 2 600 LTM Mag reak TM SMRe () SMRs () SMRg () LTM Line thermal
More informationBlock I/O Cat. No IOBA and -IOBB User Manual
User Manual Because of the variety of uses for this product and because of the differences between solid state products and electromechanical products, those responsible for applying and using this product
More informationMINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)
MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and
More informationinstallation quick guide integrated access control & environmental monitoring
installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical
More information////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)
////// SUBSTATIONS DC Switchgear Range Type MBS (IEEE/ANSI standards) GENERAL INFORMATION With a complete range of equipment and a leading expertise in DC traction power substations, Sécheron SA is a world
More informationEssential Components Catalog
Essential Components Catalog Get the right components, at the right price, right when you need them. Operator Power Logic Connectivity Safety Sensors Interface Why Choose Rockwell Automation? Get the right
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationAX200. Installation Guide
Axxess Identification Ltd 27-28 Shrivenham Hundred Business Park, Watchfield, Swindon, Wiltshire SN6 8TZ United Kingdom Tel: +44 (0)1793 784002 Fax: +44 (0)1793 784005 Email: info@axxessid.com May 2008
More information