FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK FK Protection. Trip Unit. Rated Current (A) FK800 FK1250 FK1600

Size: px
Start display at page:

Download "FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK FK Protection. Trip Unit. Rated Current (A) FK800 FK1250 FK1600"

Transcription

1 K rame reaking capacities Icu 400/45V in k eff. Type V K K2 K600 N H L Protection Trip Unit K K2 K600 Rated urrent () LTM Mag reak TM SMRe () SMRs () SMRg () LTM Line thermal magnetic protection SMRe Selective electronic protection. SMRs Selective electronic protection with enhanced functionality SMRg Selective electronic protection with enhanced functionality and ground fault Mag reak TM Magnetic only breaker for motor protection Y Non utomatic or switch (not mentioned in tables) Number of poles / protected poles (trips) 4 pole trips 4 pole 4 trips() () Switchable, 0%, % or 00% neutral protection ccessories (main types) O O2 O O4 O5 O6 maximum of one ell larm contact N aux. contacts (all of O type) Shunt or Undervoltage release Operators Rotary handle OR lectrical operator raw out system onnectors for auxiliary wiring R with separate sensor.4

2 K omplete circuit breaker Selective lectronic Trip Unit type SMRe 4 pole () N selectable 000% KV KV6NPP 44 KV46NPP 442 6NPP NPP NPP NPP k KL KL6NPP 4590 KL46NPP nhanced Selective lectronic Trip Unit type SMRs 4 pole () N selectable 000% 6NSPP NSPP NSPP NSPP 4575 K frame nhanced Selective lectronic Trip Unit type SMRg (= s + ground fault) 4 pole () N selectable 000% 6NPP NPP NPP 4 46NPP 4557 Line Thermal magnetic trip unit LTM (adjustable settings) 4 pole trips (2) KV KV6NTP 405 KV46NTP NT60P 6NTP NT60P 46NTP NT60P 6NTP NT60P 46NTP k KL 60 KL46NT60P KL46NTP 46NMP Motor Protection (Mag reak TM ) Magnetic Only reaker 4 pole trips (2) 6NMP NMP 4554 KL6NT60P KL6NTP 6NMP k KL KL6NMP 4559 KL46NMP 4554 () Switchable 0%, % or 00% neutral protection, neutral on left. (2) Neutral on left.5

3 K2 omplete circuit breaker Selective lectronic Trip Unit type SMRe 4 pole () N selectable 000% KV KV6N00SQ KV6N25SS KV46N00SQ KV46N25SS One code covers: standard fixed front connection breaker ssembled trip unit fixation hardware (lectrical Operator not possible) N00SQ 6N25SS N00SQ 46N25SS N00SQ 6N25SS N00SQ 46N25SS k KL KL6N00SQ KL6N25SS KL46N00SQ KL46N25SS nhanced Selective lectronic Trip Unit type SMRs NS00SQ 6NS25SS pole () N selectable 000% 46NS00SQ 46NS25SS KV 00k KL NS00SQ 46NS25SS 46N00SQ 46N25SS 46N00SQ 46N25SS KV6NT00S KV6NT25S KV46NT00S KV46NT25S One code covers: standard fixed front connection breaker ssembled trip unit fixation hardware (lectrical Operator not possible) NT00S 46NT25S 46NT00S 46NT25S KL6NT00S KL6NT25S KL46NT00S KL46NT25S NS00SQ 6NS25SS 6N00SQ 6N25SS 6N00SQ 6N25SS 6NT00S 6NT25S 6NT00S 6NT25S 6NM25S NM25S nhanced Selective lectronic Trip Unit type SMRg (= s + ground fault) pole () N selectable 000% Line Thermal magnetic trip unit LTM (adjustable settings) 4 pole trips (2) Motor Protection (Mag reak TM ) Magnetic Only reaker 4 pole trips (2) NM25S NM25S k KL 2 KL6NM25S 4556 KL46NM25S 4557 One code covers: standard fixed front connection breaker + ssembled dummy trip unit + Toggle elongator +.6 () Switchable 0%, % or 00% neutral protection, neutral on left. (2) Neutral on left

4 K600 omplete circuit breaker Selective lectronic Trip Unit type SMRe 4 pole () N selectable 000% KV 600 KV6N60TT 42 KV46N60TT 492 One code covers: standard fixed front connection breaker ssembled trip unit fixation hardware (lectrical Operator not possible) 600 6N60TT N60TT N60TT N60TT 45 nhanced Selective lectronic Trip Unit type SMRs NS60TT 6NS60TT pole () N selectable 000% 46NS60TT 46NS60TT K frame nhanced Selective lectronic Trip Unit type SMRg (= s + ground fault) 600 6N60TT pole () N selectable 000% 46N60TT N60TT N60TT 455 KY Nonutomatic circuit breaker (Switch) KY pole KY06NP KY06N00S KY06N25S KY06N60T pole (2) KY406NP KY406N00S KY406N25S KY406N60T One code covers: standard fixed front connection breaker + ssembled dummy trip unit + Toggle elongator + () Switchable 0%, % or 00% neutral protection, neutral on left. (2) Neutral on left

5 K Internal accessories ontacts hangeover ux. switch right mounted O ell alarm contact right mounted O NSR NR Releases lectrical operators 24V / 24 V 24 V 48 V / 48V / 0/0V / 20V 220/240V 220/24V 400V 80/440V / 20V K Operators 24V / 48V / 0V / 20V / NSHT NSHT NSHTJ NSHTN NSHT8 NM NM NMJ NMN Shunt NUVR NUVR NUVR NUVR6 NUVR8 Undervoltage elayed undervoltage NUV Keylock for electr. operator Ronis () Keylock for electr. operator Profalux () NR NP Rotary handles irect on device Rotary handle through door or cover plate (2) Panel or door mounted rey Red rey + arly closing aux. switches 2xNO () Red + arly closing aux. switches 2xNO () NNR/5 NNRV/ NNR/5 NNRV/5 NNRY/5 NNRYV/ rey Red rey + arly closing aux. switches 2xNO () Red + arly closing aux. switches 2xNO () NNR/5 NNRV/5 NNRZ/5 NNRZV/ ccessories xtension shaft kit (max. 600 mm) NNR 4578 Only for use with panel or door mounted type (c) (d) (e) lex operator adaptor push to trip daptor for drawout (c) Ronis keylock 04 nr. 027 () (d) Ronis keylock 04 nr. 05 () (d) Ronis keylock 04 nr. 292 () (d) Ronis keylock 04 nr. 29 () (d) Ronis keylock 04 nr. 296 () (d) Ronis keylock 04 nr () (d) Ronis lock with random key () (d) Profalux lock with random key () (e) NT NNRW R R2 R R4 R5 R6 RH PH Only for use with panel or door mounted type () Key included (2) dd door flange H for door lock options () On request xno/xn is available..8

6 K Residual current devices Relay I n Operating voltage Settable delay Nr. of modules Pack. R V 220V 80V 0 s 0 s 0 s R5 0 R5 220 R R V 220V 80V s s Splittable s R R6 220losed70477 R R V 220/20V 80/400V 0 s 0 s 0 s R 0 R 220 R Sensor Round Internal diameter Ø 5mm Round Internal diameter Ø 60mm Round Internal diameter Ø 80mm Round Internal diameter Ø 0mm Round Internal diameter Ø 60mm Round Internal diameter Ø 20mm Round Internal diameter Ø 22mm in Rail type Round; splittable Internal diameter Ø 0mm Round; splittable Internal diameter Ø 20mm Rectangular opening70 x 75mm Rectangular opening5 x 05mm Rectangular opening0 x mm TT 5 TT 60 TT 80 TT0 TT60 TT 20 TT 22 TTO 0 TTO 20 TR 75 TR 05 TR K frame Main system K rawout system Model with front connection omplete set for K omplete set for K2 & K600 Model with rear connection omplete set for K omplete set for K2 & K600 NWSWP NWSWT NWSP NWST pole NWS4WP NWS4WT NWS4P NWS4T 4 pole One code covers the fixed and withdrawable part of the drawout system, with plugin base, mounting accessories and fixation hardware. uxiliary disconnects (Secondary wiring) omplete set 6 pole NPM ccessories Keylock in chasis pos. Ronis 04 () Keylock in chasis pos. 2 Ronis 04 () NRW NRW Position indication contact O NSL oorflange specific for drawout type Keylock in doorflange pos. Ronis 04 () Keylock in doorflange pos. 2 Ronis 04 () NW NRY NRY Terminal extenders (2) K onnections: optional lat K K2 lat K2 K 600 NSP NSR pcs NS4P NS4R 4 pcs Terminal spreader flat (2) lat K K2 lat K2 K 600 NSSP NSSR NSS4P NSS4R Rear connections (2) Set pole (2 short, long) Set 4 pole (2 short, 2 long) NR 442 NR Set pole ( short) Set 4 pole (4 short) NRS 4426 NRS Internal box clamps (2) ox lamp u/l, for x sq.mm. ox lamp u/l, for 4 x sq.mm. NT27 NT NT427 NT () Key included (2) Set for equipping the line OR load side of breaker..9

7 K Installation ccessories Terminal shields (with finishing covers) pole 4 pole Long, set of 2 pcs. NJL 4576 NJL Specific to connection area Phase separators, set of 2 pcs NJP Padlocking devices for toggle operator () ircuit indication / coding Padlocking removable Set of 20 blank labels NPR oor flanges ront face toggle area Rotary handle (through cover plate model) Motor operator Rotary handle through cover model on drawout breaker NT NH N NHW Spare parts inishing covers (set of 2 pieces) Spare toggle (set of 5 pieces) NU NUT NU K ccessories electronic trip units attery test device NT Sensor for round fault device Sensor 000 for round fault device Sensor 2 for round fault device Sensor 600 for round fault device NS0 NS000 NS2 NS () Padlocks not included.40

FG Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FG400 FG630. Protection. Rated Current (A) Trip Unit FG400 FG630

FG Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FG400 FG630. Protection. Rated Current (A) Trip Unit FG400 FG630 rame reaking capacities Icu /415V in k eff. Type N 50 50 H 80 80 L 150 150 Protection Order codes Trip Unit Rated urrent () SMR1 Mag reak TM LTM (1) Line thermal magnetic protection SMR1 Selective electronic

More information

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction Thermal-Magnetic / Magnetic Only Molded ase ircuit reakers Introduction Table 8: reakdown of Typical atalog Number L 3 6 050 V 2100 reaker amily Y - mpere rame - 100 mpere rame K - 250 mpere rame L - 400

More information

Moulded Case Circuit Breakers Selection Information

Moulded Case Circuit Breakers Selection Information Moulded ase ircuit reakers Selection Information Industrial Thermal-Magnetic ircuit reakers lectronic Trip ircuit reakers IRUIT RKRS 3 S/UL ertified Interrupting Rating - atalogue Number Prefix ont. RMS

More information

Performance. Standards. Technical data

Performance. Standards. Technical data ilos Loadbreak disconnectors for wall mounting ilos H up to ilos up to 5 ilos 4 0 up to Order codes pplications pprovals / Marking ilos H4 ilos H ddon devices Performance Wall mounting Main disconnector,

More information

NW08 to NW63 fixed circuit breakers Circuit breakers

NW08 to NW63 fixed circuit breakers Circuit breakers fixed circuit breakers Circuit breakers DB404362.eps DB404363.eps A Masterpact fixed circuit breaker is described by 4 catalogue numbers corresponding to: b the basic circuit breaker b a control unit b

More information

Record Plus. Trip Units. Intro. Thermal Magnetic Trip Units. FD frame B.2

Record Plus. Trip Units. Intro. Thermal Magnetic Trip Units. FD frame B.2 Thermal Magnetic frame Record Plus circuit breakers are designed to isolate and switch low voltage distribution circuits and to protect the conductors, equipment and devices included in these circuits.

More information

Manual source-changeover systems Possible combinations

Manual source-changeover systems Possible combinations Manual source-changeoer systems Possile cominations A manual source-changeoer system can e installed on two or three manually-operated and mechanically interlocked circuit reakers or switch-disconnectors.

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

Series C Moulded Case Circuit Breakers Motor Circuit Protectors MCP-1. Product Description

Series C Moulded Case Circuit Breakers Motor Circuit Protectors MCP-1. Product Description July 200 Series Moulded ase ircuit reakers Motor ircuit Protectors MP-1 Motor ircuit Protectors MP/MP/MP/MPS 3- Product escription esignated as aton s utler-ammer Types MP, MP, the instantaneous-only motor

More information

Motor protection circuit breakers

Motor protection circuit breakers R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell Automation Inc. 101 South nd Street Milwaukee, WI 0 U.S.A. EU Declaration of onformity IE 0A Frame ircuit Breakers and Accessories Name and address

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

QUICK REFERENCE PRICE GUIDE JUNE 2016

QUICK REFERENCE PRICE GUIDE JUNE 2016 QUICK REFERENCE PRICE GUIDE JUNE 2016 OUR CUSTOMER CARE COMMITMENTS Quality is Guaranteed All products supplied from this Quick Price Guide carry a guarantee against defects in materials and workmanship

More information

Communication COM option in Masterpact

Communication COM option in Masterpact CT CCM modbus CD CE Functions and characteristics Communication COM option in 056431 056401 The COM option is required for integration of the circuit breaker or switch-disconnector in a supervision system.

More information

Instruction Bulletin I-Line Smart Cell Installation

Instruction Bulletin I-Line Smart Cell Installation Instruction ulletin I-Line Smart ell Installation lass 2110 Retain for future use. N999570 11/2015 NLIS Kit ontents / Necessary Tools lossary of Terms #2 Phillips screwdriver Long-shanked flat head screwdriver

More information

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 MKING MODERN LIVING POSSIBLE Technical brochure CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit- and overload protection of motor applications

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

Interpact Switch-disconnectors INS/INV40 to 2500 A. INS/INV Standard version with black handle - Fixed /FC

Interpact Switch-disconnectors INS/INV40 to 2500 A. INS/INV Standard version with black handle - Fixed /FC 28901 2890 28905 28909 28911 2891 116 1167 1169 1171 117 1175 171 159 161 16 165 167 169 111 115 11 117 119 1151 115 1155 Load s Interpact Switch-disconnectors INS/INV0 to 2500 A The Interpact INS/INV

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

MOUNTING BASE AQB-A402 PLAN VIEW OF MOUNTING BLOCK & CIRCUIT BREAKER AQB-A802 CIRCUIT BREAKER MOUNTING BLOCK 2.50 MOTOR OPERATOR 25.

MOUNTING BASE AQB-A402 PLAN VIEW OF MOUNTING BLOCK & CIRCUIT BREAKER AQB-A802 CIRCUIT BREAKER MOUNTING BLOCK 2.50 MOTOR OPERATOR 25. Weights & Dimensions 4 1/8 4 5/16 4 1/8 4 5/16 Weights & Dimensions 5 1/16 6 1/2 15 1/2 17 15/16 A C A C 6 3/16 MOUNTING ASE MOUNTING ASE 5 1/16 6 3/16 MOUNTING ASE DIMENSIONS DESCRIPTION A C SINGLE ASE,

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

LV power circuit breaker and switch-disconnectors. Masterpact NW Direct current 1000 to 4000 A. Catalogue

LV power circuit breaker and switch-disconnectors. Masterpact NW Direct current 1000 to 4000 A. Catalogue LV power circuit breaker and switch-disconnectors Masterpact NW Direct current 1000 to 4000 A Catalogue 2002 Get more with the world s Power & Control specialist Masterpact NW General contents Presentation

More information

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-... Circuit Breakers, 09/054 Moeller Electric Corporation Auxiliary Contacts for Type Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic N.O. N.C. Standard auxiliary

More information

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure MKING MODERN LIVING POSSIBLE CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M - 100 Technical brochure 2 IC.PD.C00.5.02-520B3595 Danfoss /S (R-MC/mr) 08-2009 Contents Page Circuit Breakers/

More information

Record Plus. Trip Units. Intro. Thermal Magnetic Trip Units. FE frame B.6

Record Plus. Trip Units. Intro. Thermal Magnetic Trip Units. FE frame B.6 Thermal Magnetic The breakers are availble as a complete entity or in kit form where a reaker rame and an interchangaeble trip unit are the basic components. The interchangeability feature covers the electromechanical

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches

More information

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA for ic60, iid, idpn Vigi, isw-na, RCA and ARA b The electrical auxiliaries are combined with ic60 circuit breakers, iid residual current circuit breakers, remote tripping switch disconnector isw-na, RCA

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

IEC Power Control Contactors and Contactor Assemblies

IEC Power Control Contactors and Contactor Assemblies IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,

More information

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3 Wiring diagrams Content Information for reading and graphic symbols... 5/2 Wiring diagrams of the circuit-breakers... 5/3 Electrical accessories... 5/4 5/1 Information for reading and graphic symbols State

More information

Description. Installation. Power supply

Description. Installation. Power supply Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide

More information

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka) MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and

More information

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching 7000 SERIES Power Switching Solutions Fig. 2: Four pole, Closed Transition Switch rated 1000 Amperes in Type 1 enclosure. Closed Transition Switching Closed Transition Switches feature main contacts that

More information

Air Circuit Breakers. 1/2 Introduction

Air Circuit Breakers. 1/2 Introduction /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers /5 Introduction Up to 6300 A (AC), IEC /6 Introduction /9 General data /6 3-pole, fixed-mounted versions /23 3-pole, withdrawable

More information

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-... Circuit Breakers, Disconnect Switches, Molded Case Switches 09/064 Moeller Electric Corporation Auxiliary Contacts for. Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

Powerpact 4 panelboards Panelboards and incoming devices Panelboards

Powerpact 4 panelboards Panelboards and incoming devices Panelboards Panelboards and incoming devices Panelboards Panelboards MG25C2 250A 13 way powerboard 506.76 MG25C4 250A 17 way powerboard 534.00 MG2C5 250A 5 way panelboard 620.33 MG2C7 250A 7 way panelboard 650.83

More information

GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES. March 2012 PRICE LIST

GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES. March 2012 PRICE LIST GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES March 2012 PRICE LIST Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 380 415 440 460 480 550 600 NEMA-ABI 240 (HIC) 480

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

EFACEC Aparelhagem. Customer ENA. FLUOFIX GCT (with Time Fuse Links) Project. Country. Cables colors: Cables section:

EFACEC Aparelhagem. Customer ENA. FLUOFIX GCT (with Time Fuse Links) Project. Country. Cables colors: Cables section: parelhagem partado 0 9 S. Mamede Infesta Portugal Tel (+) 900 ax (+) 99 ustomer N ables colors Green / Yellow Protection ground White Other cables Project ountry LUOIX GT (with Time use Links) UK ables

More information

Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units

Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units GE Energy Industrial Solutions GEH-704 Installation Instructions Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units

More information

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-... Circuit Breakers, 09/074 Moeller Electric Corporation Auxiliary Contacts for Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic device N.O. N.C. Standard auxiliary

More information

70 SERIES. Line monitoring relay

70 SERIES. Line monitoring relay 70 SRIS 70 SRIS lectronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window Mode, Phase

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

Motor Control Products Selection Guide

Motor Control Products Selection Guide MKING MODERN LIVING POSSIBLE Motor Control Products Selection Guide Contactors, Relays, and Circuit Breakers www.danfoss.com/ia c o n t e n t s Minicontactors CI 5 Thermal Overload Relays TI 9C for Minicontactors

More information

Motor protection circuit breakers

Motor protection circuit breakers Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability

More information

GE Consumer & Industrial Power Protection. M-PACT Plus ED.02. Air Circuit Breakers A. GE imagination at work

GE Consumer & Industrial Power Protection. M-PACT Plus ED.02. Air Circuit Breakers A. GE imagination at work GE onsumer & Industrial Power Protection ED.0 ir ircuit reakers 00 600 GE imagination at work echnical overview Order codes Wiring diagrams / Dimensional drawings Numerical index ust rel . Introduction..6.8

More information

Male header, 100% protected against mismating, (1 x 1) mm straight solder pins Pin spacing 3.5 mm 3.81 mm. light gray <_ 8,5_> 3,5 1x1 <_ 9,3_>

Male header, 100% protected against mismating, (1 x 1) mm straight solder pins Pin spacing 3.5 mm 3.81 mm. light gray <_ 8,5_> 3,5 1x1 <_ 9,3_> 96 Male Headers with Solder Pins; Double-Deck Male Headers with Solder Pins, Pin Spacing 3.5 mm and 3.81 mm 160 V/.5 kv/ 300 V, 10 A U 10 A 300 V, 10 A 160 V/.5 kv/ 300 V, 10 A U 10 A 300 V, 10 A 160 V/.5

More information

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:

More information

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches NEW P. 4 RX3 MCBs 63 A 4500 & 6000 prong type busbar MCBs, RCDs, add-on modules & accessories P. 9 DX3 RCBOs 63 A 6000 / 10 ka AC, A & Hpi type prong & fork type busbar P. 16 DX3 MCBs 63 A 50 ka mcbs,

More information

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection... .3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual

More information

Bulletin 1494H Heavy Duty Safety Switches

Bulletin 1494H Heavy Duty Safety Switches ulletin H Heavy uty Safety isconnect Switches Product Overview/Product Selection Fusible and Non-Fusible Type ulletin H Heavy uty Safety Switches switch ratings Type, R, or enclosures V: -phase, -phase,

More information

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A Fuse protection The solution for > Motor load break. > Protection of industrial cabinet. > Electrical distribution. ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications.

More information

FUSERBLOC from 30 to 800 A

FUSERBLOC from 30 to 800 A from 30 to 800 Product presentation FB30DT FB30SO Ferraz Shawmut FUSERBLO disconnect switches are extremely durable, manually operated, fusible disconnect switches. The switches employ double break contacts

More information

SACE Emax 2 Specification guide

SACE Emax 2 Specification guide SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or

More information

SENTRON Switching and Protection Devices Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers SENTRON Switching and Protection Devices ir Circuit Breakers /2 Introduction 3WL ir Circuit Breakers 3WL ir Circuit Breakers/ Non-utomatic ir Circuit Breakers up to 6300 (C) /6 - Design /2 - Function /9

More information

SENTRON 3VL Molded Case Circuit Breakers

SENTRON 3VL Molded Case Circuit Breakers Siemens AG SENTRON VL Molded Case Circuit Breakers Switching, Protection, Measuring and Monitoring Devices For the operating range from A to 00 A, the molded case circuit breaker ensures the optimum overload

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

Metal Backshell. Materials and Finishes Material: Brass Finish: 50 in. Gold over Copper

Metal Backshell. Materials and Finishes Material: Brass Finish: 50 in. Gold over Copper Subminiature Space/High Reliability Metal ackshell Metal ackshells provide strain relief. Various profiles available for different cable routing requirements. Product eatures Qualified to MIL-Spec M85049

More information

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB Motors Automation Energy Transmission & Distribution Coatings DWB Molded Case Circuit Breakers DWB Molded Case Circuit Breakers Molded Case Circuit Breakers DWB Summary Presentation 0 General Characteristics

More information

Unelec Industrial Breakers. New. Spectronic SPN. Air Circuit Breaker

Unelec Industrial Breakers. New. Spectronic SPN. Air Circuit Breaker Unelec Industrial reakers New Spectronic SPN ir Circuit reaker ir Circuit reakers Electronic Trip Units rder Codes 1 New SPN ir Circuit reakers - Easy replacement with old SP series - Designed for simplicity

More information

RATINGS AND SPECIFICATIONS

RATINGS AND SPECIFICATIONS RATINGS AND SPECIFICATIONS MCCB ELECTRICAL CHARACTERISTICS TO IEC 609472, EN 609472, JIS C 121 ANN.1, AS/NZS 39472, NEMA AB1 Frame Quantity Unit Condition 125 Model E125 S125 Number of Poles 1 Type NJ

More information

Proof 4 October 19, :49 AM

Proof 4 October 19, :49 AM Proof October, 0 : AM Time urrent urves T0N ffective eptember 0 eries R-Frame 00-00A, 0-0V ontents escription Page atalog Number election igitrip + lectronic Trip Unit types R, R ong elay Response and

More information

RW-E. Overloads. Solid-State Overload Relays. Standard Features

RW-E. Overloads. Solid-State Overload Relays. Standard Features RW-E The new RW_E Solid State Overload relays are developed with cutting edge technology according to the most demanding standards worldwide. With its wide current/mp setting; the RW_E OL Relay can be

More information

References. References. Rating (A) Référence

References. References. Rating (A) Référence DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle

More information

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation. Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation

More information

ECOFIT. Masterpact M to Masterpact NW upgrade solutions. Make the most of your energy

ECOFIT. Masterpact M to Masterpact NW upgrade solutions. Make the most of your energy Low oltage Electrical Distribution - Switchboard modernisation Catalog I 2014 ECOFIT Masterpact M to Masterpact NW upgrade solutions Make the most of your energy Masterpact M ECOFIT Contents Masterpact

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

MODEL: MAT3. [2] ALARM OUTPUT A: With Y: Without. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MAT3. [2] ALARM OUTPUT A: With Y: Without. Lightning Surge Protectors for Electronics Equipment M-RESTER MODEL: MAT Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTI SURE PROTETOR FOR THREE-PHASE POWER SUPPLY Functions & Features onnected in parallel between the power and earth lines regardless

More information

Basic principles PL. Sending units

Basic principles PL. Sending units asic principles P P technology P (Plusink) is a system for controlling light. The system is based on a conventional electrical installation. ommands are sent via P, and there is no need for either software

More information

194E FA 32 E P11 P11 6

194E FA 32 E P11 P11 6 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure

More information

Fix-o-Rail. Distribution boards. Insulated enclosures Surface mounting. Fix-o-Rail 150. Features. Approvals / Marking. Standards.

Fix-o-Rail. Distribution boards. Insulated enclosures Surface mounting. Fix-o-Rail 150. Features. Approvals / Marking. Standards. Insulated enclosures Surface mounting ix-o-rail 50 With screwless earth bar IP40 Total safety istribution boards pprovals / Marking Standards N 60439-3 pplications ix-o-rail 50 is the best choice for power

More information

Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time

Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time Catalogue G System Pack, wall mount and floor standing enclosures Prisma Plus LV Switchboards Devised to save time General contents Index 2 General presentation 8 Pack 10 17 General presentation Installation

More information

Supplemental Protectors

Supplemental Protectors compact S200 Series Miniature circuit breakers S200, S200P, S200U, S200UP Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The S2 devices are

More information

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices Siemens AG 201 SENTRON 3LD Main Control and EMERGENCY-STOP Switches Catalog Extract LV 10 Edition 10/201 siemens.com/switching-devices Siemens AG 201 Related catalogs Low-Voltage Power Distribution and

More information

WMS SUPPLEMENTARY PROTECTORS

WMS SUPPLEMENTARY PROTECTORS WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

RoHS. High shaft load capacity. Shock / vibration resistant

RoHS. High shaft load capacity. Shock / vibration resistant Due to their sturdy bearing construction in Safety-Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

Discover TeSys U motor starters open version Starter-controller Non-reversing power bases

Discover TeSys U motor starters open version Starter-controller Non-reversing power bases Discover TeSys U motor starters open version Starter-controller Non-reversing power bases DB0 DB0 LUB, LUB LUB 0, LUB 0 Two types of bases are available, each in two versions: b LUB, LUB Standard power

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Automatic Transfer Switch OTM_C_20D. Installation and Operation Instructions

Automatic Transfer Switch OTM_C_20D. Installation and Operation Instructions Automatic Transfer Switch OTM_C_20D Installation and Operation Instructions Contents 1 SYMBOLS & TERMS... 1 1.1 USE OF SYMBOLS... 1 1.2 EXPLANATIONS OF ABBREVIATIONS AND TERMS... 1 2 PRODUCT OVERVIEW...

More information

Program B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320

Program B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Push Buttons Index Page Program B3 318 Ø 22,5mm Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Rotary Knobs and Swing Knobs 321 Illuminated Rotary Knobs and Swing Knobs 321

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics SI Overcurrent and Earth Fault Protection Relay for Secondary Distribution Dual & Self Powered Main characteristics The SI is a overcurrent protection relay with self powered and dual powered (self auxiliary)