FUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC

Size: px
Start display at page:

Download "FUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC"

Transcription

1 Fuse protection The solution for > Live maintenance of speed drives supplied by a common DC bus > Live maintenance of PV inverters connected in parallel on a same circuit fuser-lm_2_a Strong points > Compact > Automatic pre-load > Integrated fuse protection Function FUSERBLOCs LMDC are designed to perform the maintenance of DC/AC speed drives or PV inverters without stopping the entire installation. This multifunctional device for performing maintenance work on a branch of the electrical system while leaving the rest of the equipment energised. FUSERBLOCs LMDC ensure a safe charge of capacitive loads by limiting high inrush current during power-up of the branch and thus reducing stress to components. Conformity to standards > IEC Advantages Compact Isolation, protection and precharge of capacitive loads within a single device. Automatic pre-load After maintenance operations, the pre-load of inverters capacitors will be managed automatically through a coil. Integrated fuse protection Semiconductors protection is integrated to the switch (no additional space is required). Characteristics 25 to 6 A DC2 2 General Catalogue 26-27

2 References External / direct operation 25 to 6 A Rating (A) No. of main poles 25 A 2 6 A 2 25 A 2 4 A 2 6 A 2 Fuse size of main poles DIN 462 DIN 462 DIN DIN 462 DIN A 2 KN/ A 4 (2 //) DIN A 4 (2 //) KN/ Pre-charge poles (DIN 462) 2 x 6 A 2 x 6 A 2 x 6 A 2 x 6 A 2 x 6 A 2 x 6 A 2 x 6 A 2 x 6 A Reference External front handle Direct front handle Shaft for external front handle Auxiliary contacts Terminal shrouds 8DR 22 ()(2) S type (4) 8DR 26 ()(2) Black IP65 Black (4) 8DR 225 ()(2) Red/Yellow IP65 44 () Coil must be ordered separately. (2) Include standard fuse protection cover. If fuse microswitch is used please use specific fuse protection cover. () Max 8 contacts (4 already provided with the switch). (4) IP2 kit, please consult us. 2 mm 4 22 U type 8DR 24 ()(2) contact NC 2 mm () DR 26 ()(2) S4 type contact NO Black IP65 5 mm Black () 8DR 29 ()(2) DR 4 ()(2) Red/Yellow IP65 8DR 46 ()(2) Characteristics according to IEC Products 25 A 6 A 25 A 4 A 6 A 9 A A 6 A size 2 No. of main poles (2 //) 4 (2 //) Fuse size of main poles / / 2 2 / K / K / Thermal current I th at 4 C (A) Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Load duty category DC-2 DC-2 DC-2 DC-2 DC-2 DC-2 DC-2 DC-2 Fuse protected short-circuit withstand Current peak value: withstand and making (peak ka) Prospective short-circuit current (ka rms) () Heat dissipation Maximum fuse dissipation per pole (W) Maximum switch dissipation per pole (W) Fuse size of pre-charge poles (DIN 462) Number of pre-charge poles Thermal current I th at 4 C (A) Rated insulation voltage U i (V) (operation circuit) Rated impulse withstand voltage U imp (kv) (operation circuit) Fuse protected short-circuit withstand Current peak value: withstand and making (peak ka) Prospective short-circuit current (ka rms) () Heat dissipation Maximum fuse dissipation per pole (W) Maximum switch dissipation per pole (W) Mechanical characteristics Endurance (number of operating cycles) (2) () Ue 4 VAC with gg fuses (AC value for information only). (2) max./hour. General Catalogue 26-27

3 Accessories Coils kit Use Accessory required for the good functioning of the product. Voltage Reference 24 VDC 8DR C24 2 VAC 8DR A2 acces_8_a_2_cat Specific protective covers for fitted fuse blown microswitch Product NFC/DIN fuse size No. of poles Reference 25 A A A A A A 2 standard A 4 (2 //) A 4 (2 //) standard acces_22_a_2_cat Solid links Product NFC/DIN fuse size No. of poles Reference 25 A A A A A A 2 consult us A 4 (2 //) A 4 (2 //) consult us fusib_24_a cat 4 General Catalogue 26-27

4 Operating diagram Pre-load auxiliary contact Auxiliary contact MANUAL - Step Coill & auxiliary contact Additional auxiliary contact 24 Vdc / 2 Vac L L2 P P fuser-lm_8_a gb_cat MANUAL - Step 2 Coill & auxiliary contact Additional auxiliary contact 24 Vdc / 2 Vac L L2 P P ! PRE-LOAD POSITION DO NOT OPERATE TO fuser-lm_9_a gb_cat POSITION OFF AUTO - Step Coill & auxiliary contact Additional auxiliary contact 24 Vdc / 2 Vac L L2 P P fuser-lm a gb_cat General Catalogue

5 Operating diagram (continued) and auxiliary contacts OFF PRE-LOAD ON OFF L / L2 P / P2 COIL AUX 6-64 fuser-lm_7_c gb_cat AUX 5-54 Dimensions DC switches 25 to 25 A A K K2 Terminal shroud J J B K H 22 K A L 45 C fuser-lm a gb_cat.eps Rating (A) Unit A A B C H J J K K K2 K L 25 in mm in mm in mm General Catalogue 26-27

6 DC switches 4 to 6 A 4 to 9 A A Connection terminals K K2 K 4 to 6 A 9 A J J B K 45 2 Ø fuser-lm_2_a.eps fuser-lm_2_a.eps to 6 A K K2 K J A J Terminal shroud L A B K H 22 A L 45 C fuser-lm_4_a gb_cat.eps Rating (A) Unit A A B C H J J K K K2 K L 4 6 in mm in mm in mm in mm General Catalogue

FUSERBLOC and high speed fuses (ur) Fuse combination switches protection of power semi-conductors up to 1250 A

FUSERBLOC and high speed fuses (ur) Fuse combination switches protection of power semi-conductors up to 1250 A fuser_47_a_1_cat The solution for > Protection of inverters and variable speed drives FUSERBLOC 60 to 150 A Strong points > Limitation of short-circuit current Extended range fuser_49_a_1_cat FUSERBLOC

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A Fuse protection The solution for > Motor load break. > Protection of industrial cabinet. > Electrical distribution. ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches

More information

SIRCO Load break switches for power distribution from 125 to 5000 A

SIRCO Load break switches for power distribution from 125 to 5000 A The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches

More information

Industrial fuses NFC-DIN industrial fuselinks gg and am curves from 0.16 to 1250 A

Industrial fuses NFC-DIN industrial fuselinks gg and am curves from 0.16 to 1250 A from 0. to 0 A Fuse protection The solution for > Motor protection > Cable and device protection fusib a cat fusib_0_c cat fusib b cat Strong points gg fuse from 0. to A > High level performances > High

More information

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:

More information

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb_cat Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle Direct handle acces_147_a_2_cat

More information

Non-Fusible Disconnect Switches

Non-Fusible Disconnect Switches UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

References. References. Rating (A) Référence

References. References. Rating (A) Référence DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle

More information

the Santon FCS-type switch Disconnect Superior Switch Solutions

the Santon FCS-type switch Disconnect Superior Switch Solutions the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

Non-Fusible Disconnect Switches

Non-Fusible Disconnect Switches UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

NH fuse-links gg VAC with striker size 0, 1, 2, 3, 4

NH fuse-links gg VAC with striker size 0, 1, 2, 3, 4 NH fuse-links gg - 690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS gg: General purpose

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

RW-E. Overloads. Solid-State Overload Relays. Standard Features

RW-E. Overloads. Solid-State Overload Relays. Standard Features RW-E The new RW_E Solid State Overload relays are developed with cutting edge technology according to the most demanding standards worldwide. With its wide current/mp setting; the RW_E OL Relay can be

More information

Protistor size 22x58 ar 690VAC (IEC) / 700VAC (UL)

Protistor size 22x58 ar 690VAC (IEC) / 700VAC (UL) 690VAC (IEC) / VAC (UL) Protistor size 22x58 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor

More information

Description. Installation. Power supply

Description. Installation. Power supply Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

Product Guide. UL 1077 DIN Rail Supplementary Protectors

Product Guide. UL 1077 DIN Rail Supplementary Protectors Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications Protection and Connection Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications DC switch-disconnectors

More information

CS8 Industrial Control Relays

CS8 Industrial Control Relays CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

Allen-Bradley 1492-RCDA4A40

Allen-Bradley 1492-RCDA4A40 Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps

More information

Disconnect Switches. Safe Switching and Disconnecting

Disconnect Switches. Safe Switching and Disconnecting IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as

More information

Ferrule fuse-links 14x51 am 500 to 690VAC

Ferrule fuse-links 14x51 am 500 to 690VAC Ferrule fuse-links 4x am 0 to 690VAC Ferrule fuse-links 4x am 0 to 690VAC LOW VOLTAGE IEC FUSES IEC CYLINDRICAL FUSE-LINKS FEATURES & BENEFITS Reduced size Striker version available for remote indication

More information

Ferrule fuse-links 22x58 am 500 to 690VAC

Ferrule fuse-links 22x58 am 500 to 690VAC Ferrule fuse-links 22x8 am 0 to 690VAC Ferrule fuse-links 22x8 am 0 to 690VAC LOW VOLTAGE IEC FUSES IEC CYLINDRICAL FUSE-LINKS FEATURES & BENEFITS Reduced size Striker version available for remote indication

More information

UL 98 Fusible Disconnect Switches

UL 98 Fusible Disconnect Switches UL 98 Fusible Mersen s fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices capable of fully rated load-break and load-make.

More information

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options otor Controllers AC Semiconductor otor Controller Type RSHR 3-Phase Soft starting and stopping of 3-phase squirrel cage motors Control of all 3 phases In Line or In Delta motor connection Low inrush and

More information

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers .2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

K1D004ACH cam switch - 4-pole A - for Ø 22 mm Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam

More information

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a otor Controllers AC Semiconductor otor Controller Type RSHR 3-Phase Soft starting and stopping of 3-phase squirrel cage motors Control of all 3 phases In Line or In Delta motor connection Low inrush and

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

Multifunction

Multifunction A = 0 047 40 0 047 41 0 047 42 0 047 00 0 047 43 0 047 45 0 047 44 Dimensions see e-catalogue For controlling the switching ON or OFF of a circuit (lighting, ventilation, automation, signalling) in operation

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor

More information

Application Note. Common Bussing AC Drives. For 584SV and 620 series drives APP-AC-02

Application Note. Common Bussing AC Drives. For 584SV and 620 series drives APP-AC-02 Application Common Bussing AC Drives APP-AC-02 For 584SV and 620 series drives APP-AC-02 2004 SSD Drives inc. 9225 Forsyth Park Drive, Charlotte, NC 28273 Page of 6 Introduction On occasion, one or more

More information

WEG Contactors - CWM and CWME Series

WEG Contactors - CWM and CWME Series Inside (877) 789 Fax () 87 WEG Contactors CWM and CWME Series International () 07 The CWM generalpurpose contactor line has been designed taking into consideration industrial duty and reliability in mind.

More information

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

MOTOR & CIRCUIT PROTECTION

MOTOR & CIRCUIT PROTECTION 2 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers p2-1 Motor Protection Relays p2-13 Thermistor Protection Relay p2-18 Fuse Holders p2-20 Miniature Circuit Breakers p2-23 Residual Current

More information

CI-tronic Reversing contactor Type RCI

CI-tronic Reversing contactor Type RCI Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast

More information

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

UL 489 Cable-In / Cable-Out Branch Circuit Breaker Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal

More information

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un): Safety module CS AR-91, according to EN 81 Safety modules for the lift automatic floor levelling operation according to EN 81 Main functions For safety applications up to SIL 3 / PL e Choice between automatic

More information

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm Characteristics body for BCD encoded output switch - 1 pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Sub-assembly

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN

More information

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm Characteristics body for BCD encoded output switch - 1 pole - 30-12 A - for Ø 22 mm Complementary Main Number of decimal 11 Switching angle 30 Range of product Product or component type Component name

More information

Ferrule fuse-links 10x38 gg 400 to 690VAC

Ferrule fuse-links 10x38 gg 400 to 690VAC Ferrule fuse-links x8 gg 400 to 690VAC Ferrule fuse-links x8 gg 400 to 690VAC LOW VOLTAGE IEC FUSES IEC CYLINDRICAL FUSE-LINKS FEATURES & BENEFITS Reduced size Full range protection Visual indication of

More information

ict contactors EN 61095, IEC 1095 Interference

ict contactors EN 61095, IEC 1095 Interference ict contactors DB23399 DB669 DB06604 Country approval pictograms EN 6095, IEC 095 ict contactors are available in two versions: b Contactors without manually-operated b Contactors with manually-operated.

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal

More information

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type Product datasheet Characteristics ABR1S102B Complementary Control circuit voltage limits Maximum switching voltage Housing colour Connections - terminals Drop-out voltage Holding current Power dissipation

More information

K1B004TLH cam switch - 1 pole A - screw mounting

K1B004TLH cam switch - 1 pole A - screw mounting Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam

More information

Protistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)

Protistor size 14x51 gr 690VAC (IEC) / 700VAC (UL) 690VAC (IEC) / 0VAC (UL) Protistor size 4x gr 690VAC (IEC) / 0VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS IEC standard 60269-4 compliant

More information

K1F006ALH cam switch - 6-pole A - screw mounting

K1F006ALH cam switch - 6-pole A - screw mounting Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting

More information

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A

More information

References. For SIRCO MV. References

References. For SIRCO MV. References 16 to 160 A Functions Dimensions sircm_071_b_1_x_cat Direct handle M00 handle sircm_041_a_1_x_cat M01 handle Handle colour Handle 16 80 100 125 Blue Blue M00-type M01-type 2299 5012 2299 5032 Handle colour

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush

More information

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu) DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables

More information

Product Guide. UL 489 DIN rail miniature circuit breakers

Product Guide. UL 489 DIN rail miniature circuit breakers Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview................................................ 2 Product Selection WMZT 10 kaic at

More information

The safest way to switch power on and off in your industrial control panels.

The safest way to switch power on and off in your industrial control panels. The safest way to switch power on and off in your industrial control panels. Your problem: You need a range of disconnect switches for your industrial control requirements ranging from Service Entrance

More information

K1D012ULH cam changeover switch - 2-pole A - screw mounting

K1D012ULH cam changeover switch - 2-pole A - screw mounting Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information

Surge Protection Devices and Surge Protection Kit

Surge Protection Devices and Surge Protection Kit Surge and Surge Kit SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors 3. Main protection - class 3 To cut-down

More information

Series 230 Automatic Transfer Switch

Series 230 Automatic Transfer Switch Series 230 Automatic Transfer Switch The Recognized Leader in Power Transfer Switch Technology Offers the Most Advanced Transfer Switches in the World. Product Overview The Series 230 automatic transfer

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush

More information

1.5 Solid State Relays

1.5 Solid State Relays Relays.. Solid State Relays Application s Pins Contacts AC ratings DC ratings Socket CSS Series AC Solid state, Instantaneous switching CSS-I A / 0 V S0 AC Solid state synch. to zero crossing CSS-Z A /

More information

Modular switch disconnectors and modular change-over switches

Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches The new generation of modular switch disconnectors is guarantee of reliability

More information

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green 22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

140M C 2 E A63 KN CC GJ

140M C 2 E A63 KN CC GJ Motor Protection Circuit Breakers Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection;

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

140M C 2 N A63 KN CC GJ

140M C 2 N A63 KN CC GJ Motor Circuit Protectors Product Overview/Catalog Number Explanation Product Line Overview C-Frame D-Frame F-Frame H-Frame J-Frame L-Frame N-Frame Max. Current I e A A A 00 A 0 A 00 A 00 A Current Rating

More information

Series 230 Automatic Transfer Switch

Series 230 Automatic Transfer Switch Series 230 Automatic Transfer Switch The Recognized Leader in Power Transfer Switch Technology Offers the Most Advanced Transfer Switches in the World. Application Product Overview The Series 230 automatic

More information

Protistor size 2x72 and 2x73 ar 550 to 1250VAC (IEC)

Protistor size 2x72 and 2x73 ar 550 to 1250VAC (IEC) Protistor size 2x72 and 2x73 ar SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination ar Class according

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary

More information