Manual PCE-A 344W Microwave Consistency Sensor

Size: px
Start display at page:

Download "Manual PCE-A 344W Microwave Consistency Sensor"

Transcription

1 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561) info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign way Hampshire / Southampton United Kingdom, SO31 4RF From outside UK: +44 Tel: (0) Fax: (0) info@pce-instruments.com Manual PCE-A 344W Microwave Consistency Sensor Version 1.1 Date of creation: Date of last change:

2 Safety precautions Before making any electrical connections, ensure that the supply voltage and frequency, as well as any other voltage is applied to meet the specifications given on the label of devices and in this manual. Incorrect connection may cause damage to the device. When installing, always observe the relevant safety regulations. Before carrying out any welding work near the appliance, make sure that the appliance is disconnected from the power supply and is not energized. Do not use the device with a damaged connecting cable insulation. In the case of damage to the cable, disconnect the device from the power supply and contact the manufacturer or seller service for replacing of the cable. In case of a fault device do not attempt to disassemble and to repair the device. In this case please contact the manufacturer or the customer service dealer for repair. During the installation, maintenance and operation of the device, remember that line of concentration measurement by the device (pipe) could be with hot water - be careful! The device must be installed in such a way as to provide easy access to control belay devices.

3 1 Application The microwave consistency sensor PCE-A 344W determines the bulk concentration of all substances entering into the composition of the suspension. It is insensitive to the type of fibers, their length, composition, grinding degree, color, and flow speed. The sensor is adapted to all types of a fibrous semi-finished product. The principle of operation is based on the precise measurement of permittivity of pulp (aqueous suspension) in the microwave range of electromagnetic waves. Sensor allows accurately measure the concentration of the pulp independently of its speed, lengths of fibers, freeness brightness, color and the type of pulp and requires minimal maintenance work after the installation. The appearance of sensor is on the Pic.1. Pic.1. The microwave consistency sensor PCE-A 344W with display unit. Constructively PCE-A 344W consists of a measuring unit is installed on the pipeline, and the display unit. The measuring unit comprises a transmitter and receiver of microwave radiation, temperature and conductivity pulp sensors and microprocessor electronics module for measuring the permittivity of the pulp taking into account its temperature and conductivity, concentration calculation and transmission of the measured data to the display unit. The display unit is used for receiving data from the measuring unit, the current value of the concentration, temperature, conductivity, forming the trend of measured values and current output signals, as well as adjusting coefficients for input. A compound of the measuring unit and the display unit provided cable comprising four twisted pairs.

4 2 Technical specifications Measurement range of consistency 0-8% Repeatability 0.02% Process temperature C Ambient temperature C Pipeline diameter 150 mm Pipeline pressure kpa Current output 4-20 ma Communication RS-232, RS-485 Pressure min. 1,5 bar Pressure max 10.0 bar Medium conductivity max mcm/cm the IP Code (International Protection IP 65 Rating) of the control panel and power supply unit Supply voltage of the control panel and VAC power supply unit max input current of the control panel 0.7A and power supply unit frequency range of the control panel 50-60Hz and power supply unit overvoltage category II the IP Code (International Protection IP 54 Rating) of the sensor supply voltage of the sensor unit 24VDC input current of the sensor unit 0.1A Attention! Specifications of consistency sensor is provided if the air content in mass not more than 1 % and the pressure in the measuring region setting unit is not less than 150 kpa. 3 Installation Measuring unit of consistency sensor is installed on a vertical or near-vertical pipe with DN 150 mm. The installation of the measuring unit on a horizontal pipeline is allowed after consultation with specialists of the company that manufactures consistency sensor. The measuring unit is installed in a pipeline as a part of pipeline and fastened thereto by tightening studs between standard flanges with rubber gaskets (Pic.2).

5 Pic. 2. Installation of measuring unit. Before installing the measuring unit is necessary to make the insertion into the pipeline. Appearance insert and method of attachment is on the Pic.3 Рic. 3. Method of attachment Appendix 1 shows drawings for manufacture of the insert. Particular attention when welding pipe flanges should be paid to the alignment of fixing holes in the top and bottom flanges (tightening rods must be parallel to the tube stock lines as shown in Pic.3). Before and after the installation place there must be a straight pipe with DN 150 mm and length not less than 200 mm. After the straight pipe with consistency sensor the additional manual valve must be installed to create a pressure in the pressure sensor at least 150 kpa at maximum machine performance. To control the pressure in the sensor area is necessary to install a manometer with a separation membrane.

6 In case of installation of the sensor with another DN of pipeline it is necessary to make reducers not less than 200 mm. The display unit is set in a convenient location for observation at a distance of 200 m from the measuring unit. Connection diagram in Appendix 2. The indication block is connected to the power supply VAC 50/60 Hz by the isolated cable of 3*0,75 size. Cable is put into the distribution cabinet, where is connected to the power supply through a circuit breaker (2A) and the power switch. 4 Controls After powering up and automatically download of the work program panel, the screen displays the current values of consistency, temperature and conductivity of the pulp. To view the trends of each measured values on the screen need to press the button "Consistency", "Temperature" or "Conductivity". To view the trend of the concentration need to press button on the panel "Consistency " and trend for the last 20 minutes of the sensor s work appears on the screen. To view the trend for other time intervals, you can use the arrows located below the graph. By clicking on the trend can obtain a digital value of the concentration at this time, which is displayed in the window on the left below the graph. It is possible to change scale of the trend. To change the maximum values must click on the maximum figure in the upper left corner of the graph, on the appeared numeric keypad enter a new maximum. The operation is completed by pressing the «ENT» on the numeric keypad. Similarly, you can change the minimum value of the trend by clicking on the minimum figure in the lower left corner of the graph. To view the trends of temperature and conductivity is possible in the same way as on the concentration. Button "Parameters" displays information about the work of sensor and has an auxiliary character. Button Settings is for correction of reading and scaling of the current output. 5 Input mode of corrections on concentration In this mode, the user is able to specify the calibration coefficients of the measuring sensor unit, if the characteristics of the pulp on this production do not correspond to the standard used for calibration of the sensor by the manufacturer. Possible difference between the readings and laboratory data may be due to the fact that the microwave sensor in its physical principle measures the volume concentration, and laboratory measurements give the weight concentration. Due to the free-air weight in the pulp results of volume concentration increase without affecting the weight, which leads to an overestimation of readings relative to

7 the laboratory data. On the other hand, when the paper manufacturing with a large percentage of mineral fillers, the proportion of which is 2-3 times higher than that of pulp can be observed under-readings compared with the results of laboratory analysis. For corrections two parameters used gain and offset. Typical values of these parameters after calibration by the manufacturer are: gain , offset After installation of sensor in pipeline performed laboratory measurements of concentration are Clab and at the time of sampling sensor readings recorded Csens. The gain is determined by the formula gain=сlab/сsens and input to the device in the Settings. The offset correction is carried out at constant (additive) difference readings from laboratory data. Increasing of offset leads to increasing of readings and conversely. The correction is carried out as follows: press button Settings, after pressing figure gain the numeric keypad appears used for enter new value of gain. To finish the operation press ENT on numeric keypad and Save on panel. Correct the offset analogously. 6 Setting current output The lower and upper limits of the current output on the concentration may be set programmatically. To install the current output limits must act by analogy with the input of correction coefficients described in Section 5. 7 Service Sensor does not require special maintenance. Periodically, at least 1 time per year, measuring unit should be removed from the pipeline and inspected inside. Upon detection of gummy deposits in the internal cavity of the measuring unit must carefully wash their by cloth moistened with an organic solvent. 8 Storage and transportation Consistency sensors should be stored on shelves in closed storage rooms at a temperature of -10 º C to +40 º C and relative humidity up to 80%. Consistency sensors transported packed in shipping containers, in closed vehicles under the following conditions: - ambient temperature from 25ºС to +50ºС;

8 - ambient relative humidity up to (95± 3)% at temperature 35ºС 9 Lifting and carrying Before lifting and carrying of device be sure it s disconnected from the power supply. The sensor and indication block (hereinafter components) carried separately manually. The connection cable between them must be disconnected. While transport device (its components) use procedure provided for lifting. Take it by lower edge of the side of the device. Do not use the connecting cable for device lifting. For carrying or transporting a special truck with a load capacity and dimensions according to these characteristics of the device described in this manual can be used. 10 Warranty The manufacturer guarantees compliance sensor passport characteristics if the consumer observes transport, storage, installation and operation rules. Warranty is 12 month from beginning of operation. The manufacturer is not responsible for warranty in the following cases: - malfunction due to improper transportation, installation, operation, and repair or modify by persons not authorized by the manufacturer to carry out such work; - mechanical damage in violation of the completeness and replacing parts without the permission of the manufacturer; Warranty questions and service: PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561) PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign way Hampshire / Southampton United Kingdom, SO31 4RF From outside UK: +44 Tel: (0) Fax: (0)

Manual PCE-A-315 Microwave Moisture Measurement Sensor

Manual PCE-A-315 Microwave Moisture Measurement Sensor PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Manual Differential pressure meter PCE-910 / PCE-917

Manual Differential pressure meter PCE-910 / PCE-917 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Manual Sound level indicator PCE-353

Manual Sound level indicator PCE-353 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Manual Anemometer PCE-423

Manual Anemometer PCE-423 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Manual Vibration Meter PCE-VT2700

Manual Vibration Meter PCE-VT2700 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Manual Light Meter PCE -174

Manual Light Meter PCE -174 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Manual Digital Thermometer PCE-T 390

Manual Digital Thermometer PCE-T 390 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Operating Manual Leakage detector PCE-LDC 10

Operating Manual Leakage detector PCE-LDC 10 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Manual Handheld Rotation Meter PCE-155

Manual Handheld Rotation Meter PCE-155 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From Outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com www.pce-instruments.com/us PCE Instruments UK Ltd. Units

More information

Manual Colour Meter PCE-CSM 5

Manual Colour Meter PCE-CSM 5 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

www.industrial-needs.com PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units

More information

Manual ph Meter PCE-228

Manual ph Meter PCE-228 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Manual Vibration Analyser PCE-VT 1000

Manual Vibration Analyser PCE-VT 1000 PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign way Southampton Hampshire United Kingdom, SO31 4RF Tel: 02380 98703 0 Fax: 02380 98703 9 info@industrial-needs.com www.industrial-needs.com

More information

LABOR-ASTER ZPM CURRENT SOURCE MODULE INSTRUCTION MANUAL

LABOR-ASTER ZPM CURRENT SOURCE MODULE INSTRUCTION MANUAL LABORASTER ZPM CURRENT SOURCE MODULE INSTRUCTION MANUAL Table of contents: 1. Introduction. 2. Scope of supply. Warranty. 3. Application. 4. Technical data. 5. Technical description. 6. Installation. Operating

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

PCE Americas Inc. PCE Instruments UK Ltd. 711 Commerce Way Units 12/13, Southpoint Business Park Suite 8 Ensign Way Jupiter, FL 33458 Hampshire / Southampton USA United Kingdom, SO31 4RF Phone: 561-320-9162

More information

Manual Infrared camera PCE-TC 30

Manual Infrared camera PCE-TC 30 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA Tel: 410-387-7703 Fax: 410-387-7714 info@pce-americas.com www.pce-instruments.com/us www.industrial-needs.com PCE Instruments UK Ltd. Units

More information

T2214. Instruction Manual

T2214. Instruction Manual Programmable atmospheric pressure transmitter T2214 with 0 to 10 V output Instruction Manual Instruction manual for use of T2214 device Device is designed for measurement of atmospheric pressure at hpa,

More information

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL

More information

ENGLISH. User manual.

ENGLISH. User manual. ENGLISH User manual Copyright HT ITALIA 2012 Release EN 2.00-18/12/2012 Table of contents: 1. PRECAUTIONS AND SAFETY MEASURES... 2 1.1. Preliminary instructions... 2 1.2. During use... 3 1.3. After use...

More information

OPERATING MANUAL. Quality control system on the production complies with requirements ISO 9001:2008

OPERATING MANUAL. Quality control system on the production complies with requirements ISO 9001:2008 Ltd Intelligent industrial electronics Astronomical time relay REV 225 OPERATING MANUAL Quality control system on the production complies with requirements ISO 9001:2008 Dear customer, Company LTD. thanks

More information

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes s 1 598 Flow sensor for liquids in DN10 25 pipes QVE3000.0xx QVE3100.0xx Vortex flow sensor made from robust red brass Output signal: DC 0 10 V or 4 20 ma Flow range: 1.8 150 l/min Used for temperature

More information

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke s 4 501 ACVATIX Electromotive actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal SAX61.. Operating voltage AC/DC 24 V, control signal DC 0 10 V,

More information

Densitometer DEN-1. Operating instructions. For version V.1GW

Densitometer DEN-1. Operating instructions. For version V.1GW Densitometer For version V.1GW Contents 1 Safety...3 2 General Information...4 3 Getting started...5 4 Operation of...7 5 Maintenance...9 6 Specifications...10 7 Guarantee and service...11 Page 3 1. Safety

More information

Scanner 2000 Steam Mass Flow Transmitter

Scanner 2000 Steam Mass Flow Transmitter 3352051/2 IM-P335-24 MI Issue 2 Scanner 2000 Steam Mass Flow Transmitter Installation and Maintenance Instructions 1. Safety information 2. Mechanical installation 3. Configuring software 4. Wiring procedures

More information

Model 332 Differential Pressure Transmitter

Model 332 Differential Pressure Transmitter Model Differential Pressure Transmitter USERS GUIDE Please read carefully before using. Manufactured by: FURNESS CONTROLS LIMITED Beeching Road, Bexhill, East Sussex, TN9 LJ, England. Telephone (044) 706

More information

Instruction Manual. T3110 T3110L T3110Ex

Instruction Manual. T3110 T3110L T3110Ex www.cometsystem.cz Instruction Manual T3110 T3110L T3110Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with 4-20 ma outputs Copyright: COMET System,

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual T0210 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual Instruction manual for use of T0210 transmitter

More information

Technical Note Series

Technical Note Series Technical Note Series pir SENSOR (T2600) S TN0012-0 0 p I R S e n s o r Page 2 IMPORTANT OPERATION INFORMATION Type BF Equipment Internally powered equipment Continuous operation WARNING Explosion Hazard;

More information

CONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL

CONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL CONVERTER OF RS-232/ INTERFACES PD51 TYPE USER S MANUAL 1 2 CONVERTER OF RS-232/ INTERFACES PD51 TYPE USER S MANUAL CONTENTS 1. APPLICATION... 5 2. CONVERTER SET... 5 3. INSTALLATION OF PD51-A TYPE...

More information

External level devices for conductive point level switch

External level devices for conductive point level switch SENSORS FOR FOOD AND BIOPHARMA. Product Information VNV-2, ZNV-2 CONTROLS External level devices for conductive point level switch Application/Specified usage Point level detection of aqueous, conductive

More information

NIR Moisture Analyzer KB-30

NIR Moisture Analyzer KB-30 NIR Moisture Analyzer KB-30 Operation Manual Safety Precautions FPL950701 Improper use of the NIR moisture analyzer in violation of the following safety notes may result in death, injury or damage to property

More information

Rocker PMR-30. Operating instructions. For version V.2GW

Rocker PMR-30. Operating instructions. For version V.2GW Rocker PMR-30 For version V.2GW Page 2 Contents 1 Safety...4 2 General Information...5 3 Getting Started...6 4 Operation of PMR-30...7 5 Specifications...9 6 Guarantee and service...10 Page 3 1. Safety

More information

Manual Ultrasonic Hardness Tester PCE-5000

Manual Ultrasonic Hardness Tester PCE-5000 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

7032 Digital-Analog Multimeter

7032 Digital-Analog Multimeter 7032 Digital-Analog Multimeter OPERATOR S MANUAL CONTENTS: 1. Safety precautions and procedures 1 1.1. Preliminary 1 1.2. During Use 2 1.3. After Use.. 2 2. General Description. 3 3. Preparation for Use..

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

Instruction book IQAN-LST. Publ no HY /UK Edition 0301 Instruction book IQAN-LST Publ no HY17-8364/UK Edition 0301 Contents 1 Introduction......................................................2 2 Precautions.......................................................3

More information

OPERATOR S MANUAL 9000U ISOLATOR

OPERATOR S MANUAL 9000U ISOLATOR OPERATOR S MANUAL 9000U ISOLATOR Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Ph: 91 79 23287275-79 Fax: 91 79 23287281,

More information

KROHNE 12/ GR Installation and Operating Instructions BM 500

KROHNE 12/ GR Installation and Operating Instructions BM 500 KROHNE 12/2003 7.02273.21.00 GR Installation and Operating Instructions BM 500 Subject to change without notice. Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic

More information

TOXALERT MODEL AIR 2000

TOXALERT MODEL AIR 2000 TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.

More information

USER MANUAL. WBI412F41 AC current transducer

USER MANUAL. WBI412F41 AC current transducer Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 989 USER MANUAL WBI2F AC current transducer www.wb-my.com wblch@wbdz.cn Technical Service:

More information

PCE-VD 3 VIBRATION DATALOGGER Instruction Manual

PCE-VD 3 VIBRATION DATALOGGER Instruction Manual PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign Way, Southampton United Kingdom, SO31 4RF Phone: +44 (0) 2380 98703 0 Fax: +44 (0) 2380 98703 9 email: info@industrial-needs.com Web:

More information

IRC 1100 Kalibrierstrahler / Calibration Source

IRC 1100 Kalibrierstrahler / Calibration Source IRC 1100 Kalibrierstrahler / Calibration Source Betriebsanleitung User Manual IMPAC - Spezialist für berührungslose Temperaturmessung IMPAC - Specialist in non-contact thermometry Content 1 General...10

More information

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor.   Operating Instructions: EN. EN/2017-04-03 Design and specifications subject to change without notice English page 1 8 Field of application CombiTemp TFRx is a temperature sensor, based on RTD technology, which is designed and produced

More information

PCE Instruments UK Ltd Units 12/13 Southpoint Business Park Ensign Way, Southhampton Hampshire United Kingdom, SO31 4RF Phone +44(0) 2380 98703 0 Fax +44(0) 2380 98703 9 info@industrial-needs.com Thermometer

More information

-bio. Densitometer DEN-1B Operating instructions

-bio. Densitometer DEN-1B Operating instructions -bio Densitometer Contents 1 Safety...4 2 General Information...6 3 Getting started...8 4 Operation of...10 5 Maintenance...12 6 Specifications...13 7 Guarantee and service...14 Version 1.01 - May 2012

More information

Total Consistency Measurement. Valmet Microwave Consistency Transmitter

Total Consistency Measurement. Valmet Microwave Consistency Transmitter Total Consistency Measurement Valmet Microwave Consistency Transmitter Experience is the key Valmet MCA is a third generation microwave consistency transmitter. All latest electronics and redesigned mechanical

More information

Electromotoric actuator

Electromotoric actuator Acvatix Electromotoric actuator SUA21/3 For zone valves AC 230 V operating voltage, 2-position control signal Positioning force 170 N Direct mounting with M30 x 1.5 union nut (no tools required) 3-wire

More information

CDD4 Duct Carbon Dioxide Transmitter

CDD4 Duct Carbon Dioxide Transmitter Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean

More information

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase

More information

-bio. Rocker PMR-30. Operating instructions

-bio. Rocker PMR-30. Operating instructions -bio Rocker PMR-30 Page 2 Contents 1 Safety...4 2 General Information...5 3 Getting Started...6 4 Operation of PMR-30...7 5 Specifications...9 6 Guarantee and service...10 Page 3 1. Safety The following

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

PIEZO FEEDER CONTROLLER

PIEZO FEEDER CONTROLLER PIEZO FEEDER CONTROLLER Instruction Manual Single-Function Type P212 P312 This Instruction Manual is applicable to Piezo Feeder Controller version 1 and later. Confirm the version information displayed

More information

Analog Resistive Touchscreen QST Series Product Specifications

Analog Resistive Touchscreen QST Series Product Specifications Analog Resistive Touchscreen QST Series Product Specifications Table of Contents 1. Product Specifications... 3 1-1. Product Applicable... 3 1-2. Structure... 3 1-3. Feature... 3 1-4. Environmental Specifications...

More information

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

EX- Documentation VA 450 / VA 452. thermal mass flow sensor EX- Documentation VA 450 / VA 452 thermal mass flow sensor This document contains important information for the installation and operation of the flow sensor in explosive environments. Please read the

More information

USER MANUAL. WBI414F21 AC current transducer

USER MANUAL. WBI414F21 AC current transducer 1 Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 1989 USER MANUAL WBI1F21 AC current transducer www.wb-my.com wblch@wbdz.cn Technical

More information

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE

More information

CMSA-100 Manual. Cinema Media Server Automation

CMSA-100 Manual. Cinema Media Server Automation CMSA-100 Manual Cinema Media Server Automation 181 Bonetti Drive San Luis Obispo, CA 93401-7397 USA Phone: +1 805 549 0161 Fax: +1 805 549 0163 www.uslinc.com Table of Contents 1. Safety Notice... 3 2.

More information

DEN-1 Densitometer Suspension turbidity detector

DEN-1 Densitometer Suspension turbidity detector Medical Biological Research & Technologies DEN-1 Densitometer Suspension turbidity detector Operating Manual Certificate for version V.1AW Contents 1. Safety Precautions 2. General Information 3. Getting

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5 EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

Led Illuminator and Light Stimulator. Model # LSD-1. Ver Led Illuminator and Light Stimulator Model # LSD-1 Ver. 2.0.0 5.16 ALA Scientific Instruments Inc. 60 Marine Street, Farmingdale, NY 11735 Voice: +1 631.393.6401 fax: +1 631.393.6407 www.alascience.com

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

SOLARIMMERSION IV Advanced Installation Manual v1.9

SOLARIMMERSION IV Advanced Installation Manual v1.9 SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

MDM 011-Z1 Regen Resistor

MDM 011-Z1 Regen Resistor MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18

More information

Orbital Shaker OS-10. Operating Manual Specifications Certificate

Orbital Shaker OS-10. Operating Manual Specifications Certificate Orbital Shaker OS-10 Operating Manual Specifications Certificate Contents 1. Safety P recautions 2. General Information 3. Getting Started 4. Operation of the Shaker 5. Specifications 6. Technical Maintenance

More information

USER MANUAL. WBV412U01 AC voltage transducer

USER MANUAL. WBV412U01 AC voltage transducer Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 1989 USER MANUAL WBV412U01 AC voltage transducer www.wb-my.com wblch@wbdz.cn Technical

More information

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately) Solid-state Timer Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301 Instruction book IQAN-LSL Publ no HY17-8367/UK Edition 0301 Contents 1 Introduction......................................................2 2 Precautions.......................................................3

More information

Family of Water Cut Analyzers

Family of Water Cut Analyzers Phase Dynamics Technology for Precision Measurements Phase Dynamics, Inc. 1251 Columbia Drive Richardson, TX 75081 USA E-Mail sales@phasedynamics.com Tel: 972-680-1550 Fax: 972-680-3262 Family of Water

More information

Mini-Rotator with timer for test tubes PTR-25

Mini-Rotator with timer for test tubes PTR-25 Mini-Rotator with timer for test tubes PTR-25 For version V.1GW Contents 1 Safety...3 2 General Information...5 3 Getting started...6 4 Operation...7 5 Specifications...9 6 Guarantee and service...10 7

More information

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X R Calibration Technology High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X WIKA Data Sheet CT 28.01 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL

More information

TEK-THERMAL 1700B Thermal Mass Flowmeter

TEK-THERMAL 1700B Thermal Mass Flowmeter TEK-THERMAL 1700B Thermal Mass Flowmeter Instruction Manual Document Number: IM-1700B NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance,

More information

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230 P/N 0-027289 (Rev. A 04/4) NT PRESSURE TRANSDUCER MODELS 400, 420, 430, 4230 User Guide Table of Contents Safety Alert Symbol... 2 Introduction... 3 Installation... 3 Mechanical Installation... 3 Electrical

More information

Operating Instructions Differential Pressure Transducer PS27

Operating Instructions Differential Pressure Transducer PS27 Operating Instructions Differential Pressure Transducer PS27 halstrup-walcher GmbH Stegener Straße 10 79199 Kirchzarten/Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-mail: info@halstrup-walcher.com

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue August 2016 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for

More information

GS 8 B Calibrated Flow Simulator for Electromagnetic Flowmeters

GS 8 B Calibrated Flow Simulator for Electromagnetic Flowmeters AK REV 1.3 KROHNE 7/2006 Technical Data and Operating Instructions GS 8 B Calibrated Flow Simulator for Electromagnetic Flowmeters General Operational Safety Advice Incorrect connection of the GS 8 B or

More information

Instruction Manual P82R Differential Pressure Transducer with Root- Extracted Characteristic Curve

Instruction Manual P82R Differential Pressure Transducer with Root- Extracted Characteristic Curve Instruction Manual P82R Differential Pressure Transducer with Root- Extracted Characteristic Curve halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Germany Phone: +49 (0) 76 61/39 63 0 Fax:

More information

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06 PRODUCT MANUAL Rotork YTC Limited VERSION 1.06 Contents 1 Introduction... 3 1.1 General Information for the users... 3 1.2 Manufacturer Warranty... 3 1.3 Explosion Proof Warning... 4 2 Product Description...

More information

Environdata FA ma Converter Guide

Environdata FA ma Converter Guide FA12 4 20 ma Converter Guide REV 14 th July 2015 Material in this Handbook is copyright. All rights reserved by the publishers. Weather Stations Pty. Ltd., 42-44 Percy Street, Warwick, Queensland, AUSTRALIA,

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL Contents 1. APPLICATION... 5 2. CONVERTER SET... 5 3. CONVERTER INSTALLATION... 6 3.1. Converter installation and safety requirements... 6 3.2. Description

More information

DI572 Digital Input Module

DI572 Digital Input Module Ordering Data DATA SHEET DI572 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 230 500 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE 968

More information

1. Safety Precautions (Read these precautions before use.)

1. Safety Precautions (Read these precautions before use.) R P5102S/N/N1 HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions

More information

OPERATION MANUAL MODEL TT-LP

OPERATION MANUAL MODEL TT-LP TURTLE TOUGH OPERATION MANUAL MODEL TT-LP 2-Wire Isolated ph/orp Transmitter turtletough.com.au CONTENT INITIAL INSPECTION 3 INTRODUCTION 3 ASSEMBLY 4 PREPARATION 5 Connection Diagram of Turtle Tough Sensors

More information

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply. Universal Isolation Amplifiers The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply. The Housing At a width of just 12.5 mm, the modular housing with pluggable

More information

Electromotive actuators for combi valves

Electromotive actuators for combi valves s 4 833 ACVATIX Electromotive actuators for combi valves For combi valves VPF43.. and VPF53.. SQV..P.. SQV91.. Operating voltage AC/DC 24 V, Positioning signal 3-position, DC 0-10 V, DC 4-20 ma Position

More information

MTU5. Warranty. Factory Test Certificate. Ultrasonic level transmitter. Technical Data. MTU5... Production and check date:...

MTU5. Warranty. Factory Test Certificate. Ultrasonic level transmitter. Technical Data. MTU5... Production and check date:... Ultrasonic level transmitter 825B136A Technical Data Housing material: PC / PP wetted part Mechanical installation: DN150 PP flange or bracket Protection degree: IP67 / IP68 (sensor) Electrical connection:

More information

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Description Features Application The Powermite 599 MT Series SAS Electronic Valve Actuator requires a 24 Vac

More information

Position sensor PO1 series 20

Position sensor PO1 series 20 Position sensor PO1 series 20 RE 95160 Edition: 09.2013 Replaces: 03.2012 Inductive sensor for position measurement Features Axially moving button with spring preload Inductive element according to the

More information