Type IBS IP CBK 1/24-F IBS CCO-R/L IBS CCO-PSM/L IBS CCO-PSF/L IBS IP PROT-CCO. 24 V DC 3.6 V pp V DC ripple included 120 ma
|
|
- Todd Grant
- 5 years ago
- Views:
Transcription
1 Module no: LabelId: Operator:Phoenix 3:2:03, Mittwoch,. März 2000 IBS IP CBK /24-F Installation remote bus terminal, module 24 V DC Design width 75 Description IP-65 bus terminal module Accessories Bus connector set Power supply connectors, Protective cap, for bus and power supply connectors, brass/chrome-plated Technical data Interfaces Power supply Voltage Ripple F male female Allowable range current consumption Module electronics Current consumption Supply of the modules in the installation remote bus Electrical isolation remote bus/remote bus, installation remote bus Max. number of I/O modules Installation remote bus length Polarity reversal protection Connection of a reconfiguration switch Alarm output Housing Dimensions (WxHxD) Degree of protection Mounting Local diagnostics Power supply voltage (Bus logics): U L Type IBS IP CBK /24-F IBS CCO-R/L IBS CCO-PSM/L IBS CCO-PSF/L IBS IP PROT-CCO Order No Pcs. Pkt. Set Remote bus and installation remote bus, IP-65 round connector (CCO) 24 V DC 3.6 V pp V DC ripple included 20 ma max. 4.5 A depending on the current consumption of the modules connected max. 50 m yes M 2 connector Electrically isolated contact 00 V; 0.5 A (75 x 80 x 60) mm IP 65 wall mounting, without opening the device Phoenix Contact Elektronischer Katalog Page / 2
2 Module no: LabelId: Operator:Phoenix 3:2:03, Mittwoch,. März 2000 Power supply voltage (Bus logics): U L Power supply voltage (installation remote bus):u S Remote bus connection OK: RC Remote bus active: BA Installation remote bus faulty: E Installation remote bus disabled: LD Remote bus disabled: RD Programmable diagnostic functions Housing without connectors Dimensional drawing /red LED red LED red LED red installation remote bus disabled, installation remote bus reset, reconfiguration, alarm Phoenix Contact Elektronischer Katalog Page 2 / 2
3 Module no: LabelId: Operator:Phoenix 3:08:37, Mittwoch,. März 2000 IBS IP CDI 3/24-F 8 digital inputs, 24 V DC Design width 75 Description Input/Output module IP 65, Installation remote bus terminal (5-pos. initiator connector) Accessories Bus connector set Protective cap, for bus and power supply connectors, brass/chrome-plated Protective cap, for initiator connectors, plastic Technical data Interfaces Power supply Voltage Ripple Allowable range Current consumption from the installation remote bus Electrical isolation Bus/input or output Bus/supply voltages (U S ) Inputs/Outputs Number Connection type Input current per channel Initiator supply current Short circuit protection Housing Dimensions (WxHxD) Degree of protection Mounting Local diagnostics I/O status / short circuit F Type Order No. IBS IP CDI 3/24-F IBS CCO-R/L IBS IP PROT-CCO IBS IP PROT-I/O installation remote bus 24 V DC 3.6 V pp V DC ripple included 75 ma plus supply current of the sensors 8 4-wire typ. 7 ma max. 0.5 A (from 35 C derating 2%/K ) electronic, per input (75 x 80 x 60) mm IP 65 wall mounting, without opening the device LED yellow/red Pcs. Pkt. Set 5 Power supply voltage Phoenix Contact Elektronischer Katalog Page / 2
4 Module no: LabelId: Operator:Phoenix 3:08:37, Mittwoch,. März 2000 pp y g Bus active Installation remote bus OK: RC Supply, I/O Error messages via the bus Short circuit yes Dimensional drawing g Phoenix Contact Elektronischer Katalog Page 2 / 2
5 Module no: LabelId: Operator:Phoenix 3:08:42, Mittwoch,. März 2000 IBS IP CDO 3/24-F 8 digital outputs, 24 V DC, 500 ma Design width 75 Description Input/Output module IP 65, Installation remote bus terminal (5-pos. initiator connector) Accessories Bus connector set F Power supply connectors, male female Protective cap, for bus and power supply connectors, brass/chrome-plated Protective cap, for initiator connectors, plastic Technical data Interfaces Power supply Voltage Ripple Allowable range Current consumption from the installation remote bus Electrical isolation Bus/input or output Bus/supply voltages (U S ) Inputs/Outputs Number Initiator supply current Output current per channel Short circuit protection Housing Dimensions (WxHxD) Degree of protection Mounting Type Order No. IBS IP CDO 3/24-F IBS CCO-R/L IBS CCO-PSM/L IBS CCO-PSF/L IBS IP PROT-CCO IBS IP PROT-I/O installation remote bus 24 V DC 3.6 V pp V DC ripple included 00 ma 8 3-wire 500 ma (from 35 C derating 2%/K) electronic, per output (75 x 80 x 60) mm IP 65 wall mounting, without opening the device Pcs. Pkt. Set 5 Phoenix Contact Elektronischer Katalog Page / 2
6 Module no: LabelId: Operator:Phoenix 3:08:42, Mittwoch,. März 2000 Local diagnostics I/O status / short circuit Power supply voltage Bus active Installation remote bus OK: RC Supply, I/O Error messages via the bus Failure of actuator voltage Short circuit Dimensional drawing LED yellow/red /red no yes Phoenix Contact Elektronischer Katalog Page 2 / 2
Type IBS EVA BASIC IBS EVA ADDITION 1 IBS EVA ADDITION 2 IBS SIG PART 2 UM IBS SIG PART 2 UM E. length: 50 mm acc. to RS x 9-pin D-SUB
Module no:272387 LabelId:272387 Operator:Phoenix 2:37:58, Mittwoch,. März 2000 IBS EVA BOARD Evaluation board, Basic Addition Addition 2 IBS EVA BASIC Remote bus module Connection SUPI 3 module Protocol
More informationSKBI 64/C 32. Module no: LabelId: Operator:Phoenix 12:20:17, Mittwoch, 1. März Phoenix Contact Elektronischer Katalog Page 1 / 2
Module no:2265034 LabelId:2265034 Operator:Phoenix 2:20:7, Mittwoch,. März 2000 SKBI 64/C 32 (IEC) rigid flexible I U [mm 2 ] solid stranded AWG [V] Connection data 0.2-4 0.2-2.5 24-2 250 2 ) 2 ) Surge
More informationIBS ST (ZF) 24 BK LB-T
. - IBS ST (ZF) 24 BK LB-T Bus Terminal Module With Local Bus Branch Data Sheet 5049B 09/1999 5049B000 ' " # " % 1 6-4 * 7 5 7 4 + * ) * ) - -,, 4, 4 A? BEC K H= JE 7 5 * K I 6 A H E = " 8, + @ K A 1@
More informationIBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description
IBS ST 24 BK-T Data Sheet INTERBUS-S Bus Terminal Module Data Sheet Revision A 08/994 Product Description The IBS ST 24 BK-T bus terminal module is the head station for an INTERBUS ST compact station in
More informationIBS RT 24 BK RB-T. Extract from the online catalog. This item is no longer available. Should you have any questions, please contact our Sales Team.
Extract from the online catalog IBS RT 24 BK RB-T This item is no longer available. Should you have any questions, please contact our Sales Team. Order No.: 2750484 INTERBUS-ST bus terminal module, 24
More informationPHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.
INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More informationFLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet
Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system
More informationOnline data sheet VL18-4P3140 V18 CYLINDRICAL PHOTOELECTRIC SENSORS
Online data sheet VL8-P0 V8 VL8-P0 V8 A B C D E F Illustration may differ Ordering information Type Part no. VL8-P0 605 Other models and accessories www.sick.com/v8 H I J K L M N O P Q R S T Detailed technical
More informationOnline data sheet VS/VE18-4P3140 V18 CYLINDRICAL PHOTOELECTRIC SENSORS
Online data sheet VS/VE8-P0 V8 VS/VE8-P0 V8 A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Sensor/ detection principle Housing design (light emission) Housing
More informationOnline data sheet VTE18-4P4240 V18 CYLINDRICAL PHOTOELECTRIC SENSORS
Online data sheet VTE8-P0 V8 VTE8-P0 V8 A B C D E F Illustration may differ Ordering information Type Part no. VTE8-P0 606 Other models and accessories www.sick.com/v8 H I J K L M N O P Q R S T Detailed
More informationIB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description
INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is
More informationModule no: LabelId: Operator:Phoenix 14:20:45, Mittwoch, 1. März 2000
PLC-O M 8 "...6" Equipped with pluggable miniature optical coupler Terminal width 6.2 VDE, UL, CSA applied for (IEC) [mm 2 ] Connection data rigid solid 0.14-2.5 flexible stranded 0.14-2.5 AWG 26-14 I
More informationVersaMax IP I/O Module
Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)
More informationPLC-OPT- 24DC/230AC/1
Extract from the online catalog PLC-OPT- 24DC/230AC/1 Order No.: 2900369 PLC-INTERFACE, consisting of PLC-BPT basic terminal block with Push-in connection and plug-in miniature solid-state relay, for mounting
More informationData sheet CPU 115 (115-6BL02)
Data sheet CPU 115 (115-6BL02) Technical data Order no. 115-6BL02 Type CPU 115 General information Note - Features 16 (20) inputs 16 (12) outputs from which are 2 PWM 50 khz outputs 16 kb work memory,
More informationILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description
Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS
More informationTemperature module. 4 inputs for thermocouples
2 Bosch Rexroth AG Electric Drives and Controls Documentation 4 inputs, M12 Thermocouples (TC) M12 Technical data S67-AI4-UTH-M12 Local bus interface Designation System bus M12 connector, B-coded, 5-pin,
More informationRemote Process Actuation Control System AirLINE PHOENIX INLINE
Remote Process Actuation Control System AirLINE PHOENIX INLINE Type 8644 can be combined with... Fully compatible with Phoenix Inline System Combination of Fieldbus, pilot valves and I/O modules High flexibility
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationAS-Interface I/O Module
AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard
More informationD6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D
D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General
More informationUNAM 12I9912/S14. Ultrasonic distance measuring sensors. Ultrasonic sensors. Analog. dimension drawing. general data. photo
UNAM 12I9912/S14 dimension drawing SW 17 55 70 LED general data photo scanning range Sd scanning range close limit Sdc scanning range far limit Sde repeat accuracy < 0,5 mm resolution < 0,3 mm response
More information8B0C0320HW General information. 2 Order data. 3 Technical data 8B0C0320HW
1 General information Connections for supplying external 24 V devices Extensive protective measures 2 Order data Model number Short description Figure Wall mounting ACOPOSmulti auxiliary supply module,
More informationPROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP
FBP FieldBusPlug V6 PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP PDP21-FBP PROFIBUS DP FieldBusPlug PROFIBUS DP Fig. 1: PDP21-FBP Fig. 2: PDP21-FBP, plugged to the Universal Motor Controller UMC22-FBP
More informationFeatures. Sensing range 50 mm mm... Type of light. Light source 3) Wave length. Adjustment 2) PL80A.
-3-3 Detailed technical data Features WT18-3 WT18-3 Ex WL18-3 WL18-3 Ex WS/WE18-3 Reliable object detection for demanding applications Sensor principle Photoelectric proximity sensor Through-beam photoelectric
More informationOnline data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS
Online data sheet TBS-1BSGT3506FM TBS A B C D E F Illustration may differ Detailed technical data Features Ordering information Type Part no. TBS-1BSGT3506FM 6053202 Other models and accessories www.sick.com/tbs
More informationIBS IL 24 BK RB-T-2MBD
IBS IL 24 BK RB-T-2MBD INTERBUS Inline Terminal for Connecting a Remote Bus Branch Data Sheet 6766A 01/2003 $! $ * This data sheet is only valid in association with the "Configuring and Installing the
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector
Characteristics expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus type [Ue] rated operational
More informationEnergetic diffuse reflection light scanner. Dimensioned drawing
Energetic diffuse reflection light scanner Dimensioned drawing We reserve the right to make changes 93_c3gb.fm Part No. 51 1168 1-3 V DC 5 17mm 1mm Infrared light Background suppression through appropriate
More informationTM7NCOM16A CANopen interface block - IP67-16 I/O - M12
Characteristics CANopen interface block - IP67-16 I/O - M12 Main Range of product Product or component type Range compatibility Enclosure material Bus type [Ue] rated operational voltage Input/Output number
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More information4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection
4.8 Digital Input/Output Module 07 DC 9 3 configurable digital inputs/outputs, 4 V DC, electrically isolated in groups, outputs can be loaded with 500 ma, CS31 system bus 1 3 4 1 Fig. 4.8-1: Digital input/output
More informationVAL-62. Fieldbus modules FD67 Series Input, output and analog modules with IP67 ingress protection. Valves
Valves Fieldbus modules Reduced cabling and installation costs 256 I/O per node Single channel diagnostics IP67 Ingress protection Fully configurable I/O points Compact, robust construction Fieldbus nodes,
More informationGFK-2415A March Type of sensor connection
VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by
More information4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm
Inductive Sensor Double Sensing Distance Model Number Legend SALIENT FEATURES IP - 7, Brass Housing Short - Circuit protection Reverse Polarity Protection Shielded and Non - Shielded Prewired and Connector
More informationPSI-GPRS/GSM-MODEM/RS232-QB
Extract from the online catalog PSI-GPRS/GSM-MODEM/RS232-QB Order No.: 2313106 Industrial GPRS/GSM modem for assembly on EN DIN rail. GSM and GPRS. 850 + 900 + 1800 + 1900 MHz. Serial RS-232 interface.
More informationRemote Process Actuation Control System AirLINE PHOENIX INLINE
Remote Process Actuation Control System AirLINE PHOENIX INLINE Type 8644 can be combined with... Fully compatible with Phoenix Inline System Combination of Fieldbus, pilot valves and I/O modules High flexibility
More informationData sheet VIPA CPU 115DP (115-6BL22)
Data sheet VIPA CPU 115DP (115-6BL22) Technical data Order no. Type 115-6BL22 VIPA CPU 115DP General information Note - Features Work memory [KB]: 16 Load memory [KB]: 24 Onboard 16x DI / 12x DO / 4x DIO
More informationInstallation and Programming Manual. This Manual describes the IBSS InterBus-S Slave, its uses and set up.
IBSS Manual IBSS Installation and Programming Manual This Manual describes the IBSS InterBus-S Slave, its uses and set up. Effective: 03 June, 1996 Niobrara Research & Development Corporation P.O. Box
More informationBMX DDM Mixed Relay Input/Output module
Modicon M340 Using Unity Pro BMX DDM 16025 35012474 07/2012 BMX DDM 16025 Mixed Relay Input/Output module 22 Subject of this Section This section presents the BMX DDM 16025 module, its characteristics,
More informationIB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B
INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area Data Sheet 5764B 09/2000 # % $ This data sheet is only valid in association with the INTERBUS Inline System Manual IB IL SYS
More informationFieldline. 4 digital inputs, 4 digital inputs/outputs RF-FLM DIO 8/4 M8
4 digital inputs, 4 digital inputs/outputs 2 Bosch Rexroth AG Electric Drives and Controls Documentation Technical data Local bus interface Designation Local bus M8 connector Supply for module electronics
More informationGS202 Encoder Switch
GS202 Encoder Switch 20:2 encoder switch 20 encoder inputs (TTL / RS422 standard) Input signals A, /A, B, /B, Z, /Z on each encoder input 2 x 6 control inputs (HTL / PNP) 2 encoder outputs (TTL / RS422
More informationProduct description. The ability to teach up to four colors can lead to faster changeovers and shorter downtime. The CS8 series offers high
S8 OLOR SENSORS Product description The ability to teach up to four colors can lead to faster changeovers and shorter downtime. The S8 series offers high (85 µsec) enabling higher throughput. And, the
More informationAXL E IOL AO1 U M12 R
Axioline E IO-Link/analog converter for connecting an analog actuator, 0 V... 10 V, rectangular version Data sheet 8588_en_03 PHOENIX CONTACT 2014-09-22 1 Description The IO-Link/analog converter is an
More informationInclination sensors 2-dimensional, measuring range up to ±90
Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R
More information4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus
4.7 Digital Input/Output Module 16 digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 4 V DC, CS31 system bus 1 3 Advant Controller 31 I/O Unit ERR Test 4 1 Fig. 4.7-1: Digital input/output
More informationAXL E PB DIO16 M12 6P
Axioline E PROFIBUS device, plastic housing, 16 freely configurable inputs or outputs, 24 V DC, M12 fast connection technology Data sheet 8437_en_03 PHOENIX CONTACT 2015-09-03 1 Description The Axioline
More informationLED DALI Sequencer - User Manual
LED Sequencer - User Manual Item No.: LC-004-800 1. Product Description The Sequencer is a Control unit for automatic retrieval of sequences and have a memory for 4 sequences. A sequence can combine various
More informationPLC-OPT-230UC/ 24DC/2
Extract from the online catalog PLC-OPT-230UC/ 24DC/2 Order No.: 2900368 PLC-INTERFACE, consisting of PLC-BPT basic terminal block with Push-in connection and plug-in miniature solid-state relay, for mounting
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationIB IL 24 DI 16 IB IL 24 DI 16-PAC
IB IL 24 DI 16 IB IL 24 DI 16-PAC Inline Terminal With 16 Digital Inputs Data Sheet 555302 06/2003 + Features This data sheet is only valid in association with the IB IL SYS PRO UM E User Manual or the
More informationAS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports
/ IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital
More informationAS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input
Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20
More informationILC 200 IB ILC 200 IB-PAC
ILC 200 IB ILC 200 IB-PAC Inline Controller with Programming Capabilities According to IEC 61131-3 Data Sheet 5883C04 07/2010 & & * ILC 200 IB and ILC 200 IB-PAC only differ in the scope of supply (see
More informationCDN220 HIGH DENSITY I/O ADAPTER USER GUIDE
CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE 13022001 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS CDN220 PRODUCT OVERVIEW 1 CDN220 INSTALLATION 2 POWER
More informationOvervoltage Protection
Overvoltage Protection Weidmuller has a complete line of overvoltage protection devices to effectively stop the harmful effects of electrical overvoltage and electrical noise. There is strong potential
More informationDiagnostics (Physical)
DeviceNet Spanner Rugged, Fully Potted Stations IP 67 Protection Communicate Between s Connect Two DeviceNet Networks FDN-DN1 Electrical Operating Current: 125 ma from segment A, 30 ma from segment B Power
More informationTM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box
Product datasheet Characteristics TM7BDM8B Main Range of product Product or component type Range compatibility Enclosure material Bus type System Voltage Input/output number 8 Input/output number of splitter
More informationSmartWire-DT Modules IP67
Manual 05/15 MN120006EN SmartWire-DT Modules IP67 All proprietary names and product designations are brand names or trademarks registered to the relevant title holders. Break-Down Service Please call your
More informationEasy Analog RNB130. Technical Information. Primary switched-mode power supply
Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power
More informationAdvant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System
Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.
More informationAnalog input module. 4 inputs, voltage and current
2 Bosch Rexroth AG Electric Drives and Controls Documentation 4 inputs: M12, 0 to 20 ma, 4 to 20 ma, ±20 ma, 0 to 10 V, ±10 V Technical data S67-AI4-U/I-M12 Local bus interface Designation System bus M12
More informationSAI Active Universal Pro
Universal Pro - Overview Universal Pro Professional versions of the Remote I/O System featuring IP67 protection The modules in the Universal Pro systems provide additional I/O and functional modules for
More informationRugged metal housing provides exceptional performance in demanding applications. Product description
W- Small photoelectric sensors W Rugged metal housing provides exceptional performance in demanding applications Product description The W- family features a complete range of photoelectric sensors that
More informationPLC-RSC- 24DC/21 Order No.:
Typical release time Operating voltage display Name of protection Protective circuit/component 8 ms Yes Polarity protection Polarity protection diode Contact side Contact type Contact material Maximum
More informationDigital I/O modules. 8 inputs/outputs, M8
2 Bosch Rexroth AG Electric Drives and Controls Documentation Digital I/O module 8 inputs/outputs 0.5 A per channel M8 Technical data S67-DIO8-M8 Local bus interface Designation System bus M12 connector,
More informationIBS IL 24 RB-LK-2MBD:
Inline Branch Terminal for an INTERBUS Remote Bus; Connections Using Fiber Optics RC D RD LD RB-LK FO AUTOMATIONWORX X2 X1 OUT Data Sheet PHOENIX CONTACT - 08/2005 Description The branch terminal is designed
More informationSafety. Detection. Control. MAGNUS RFID ENG - REV
03 2017 1 Next generation RFID safety sensor 03 2017 2 03 2017 3 Next generation sensors for machine safety RFID safety sensors PL e, SIL 3 The application of Magnus RFID sensors can be extremely wide
More informationDigital Modules AS-i in IP20, 22,5 mm
Digital Modules AS-i in 22,5 mm Cost efficient solution in IP20 (Figure similar) Figure Type Housing s digital digital voltage (sensor supply) (1) Output voltage (actuator supply) (2) AS-i connection (3)
More informationCommunication modules. Serial interface module
2 Bosch Rexroth AG Electric Drives and Controls Documentation 2 serial channels RS232, RS485/422 4 digital inputs/outputs M12 Technical data S67-RS-UNI-M12 Local bus interface Designation System bus M12
More informationScreenLine Accessories MB model
ScreenLine Accessories MB model ST2121 Control Module 1 group of blinds (PC configuration) control (Potential separated) Individually configurable via Configuration Utility (PC) DIN rail mounting Dim.:
More informationLinear measuring technology
Draw wire encoder C00 Thanks to its roust design and its high IP67 protection level, the draw wire encoder C00 relialy provides accurate length measurement Its simple and optimal integration in the application
More informationVersaPoint I/O Module
Output 24VDC Positive Logic 0.5A 14 Points Module is used to output 24VDC digital signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature 48.8mm
More informationIB IL 24/48 DOR 2/W-XC-PAC
Inline digital output terminal, version for extreme conditions, 2 relay PDTs Data sheet 8463_en_01 PHOENIX CONTACT 2015-08-12 1 Description The terminal is designed for use within an Inline station. It
More informationDI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide
DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) SIMATIC ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Manual Preface Documentation guide 1 Product overview 2 Connecting 3 Parameter
More informationArticle no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC
Safety + standard I/O in one module AS-i Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category
More informationAS-i Safety Output Module, IP20
a AS-i Safety Output Module Safe outputs and standard inputs in one module Protection category IP20 Figure Housing Inputs digital Outputs Safety, SIL3, cat.4 Input voltage (sensor supply) 1 Output voltage
More informationSafety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC
Non-contact safety system CES-FD- Evaluation of signals in the field Connection of CES read heads Connection to the ET200s and ET200pro Familiar EUCHNER AP interface Functional description Field evaluation
More informationTM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector
Characteristics expansion block - TM7 - IP67-16 DI/DO - 24V DC - 0.5 A - M12 connector Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 753.00 USD Main Range of
More informationFL SWITCH SFN 5TX. Extract from the online catalog. Order No.:
Extract from the online catalog FL SWITCH SFN 5TX Order No.: 2891152 Ethernet switch, 5 TP RJ45 ports, automatic detection of data transmission rate of 10 or 100 mbps (RJ45), autocrossing function Commercial
More informationAbsolute Encoders Multiturn
The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow
More informationHardware Manual RM Display 2401
Hardware Manual RM Display 2401 Table of Contents 1 Legal Regulations...3 2 About the Display 2401...4 3 Important information for using RM Display 2401...5 4 Disposal...5 5 Installation...6 5.1 VESA 100
More informationConnecting a Cisco Output Module
CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which
More informationSolid State Remote Power Controller E
Description The E-T-A is a transistorised switching device providing both protection and signalisation. It is suitable for all applications where the capabilities of the existing PLC s are not sufficient
More informationADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing
Dimensioned drawing en 2-214/2 5124879 25 4mm 15 13mm 15-3 V DC We reserve the right to make changes DS_HTU418BX3LT4_en_5124879.fm Largely surface-independent function, ideal for the detection of liquids,
More informationSignal types Coupler Box and PLC Box
Signal types Coupler ox and PLC ox Fieldbus interface (connection depends on the particular fieldbus) Fieldbus status display Hinged inspection window Address selection switch and diagnostic interface
More informationActive Distributors AS-i Safety, Active Distributors AS-i
Active Distributors Safety, Active Distributors x connectors for Periphery connection via, M cable sockets or push in terminals (Figure similar) Figure Type Inputs Safety, SIL, Cat. x 9 mm, -channels Safety
More informationAS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports
/ IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master in one housing Power supply of s (or ) (Figure similar) Figure Type Inputs digital 4 x + 4 x + 4 x Outputs digital M12
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof
More informationComoNeo. Electronics & Software. System for Process Monitoring and Process Optimization in Plastic Injection Molding Applications. Type 5887A...
Electronics & Software ComoNeo System for Process Monitoring and Process Optimization in Plastic Injection Molding Applications Type 5887A... ComoNeo is a process monitoring system made by Kistler that
More information4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module electronics
More informationRotary Measurement Technology Absolute Encoders, Singleturn
-20 to 85 C High rotational speed Temperature Shock/ vibration resistant Short-circuit proof Reverse polarity protection Rugged Highest shock resistance on the market: ( 200 g (2,500 m/s 2 )), 6 ms acc.
More informationXUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN
Characteristics photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN Complementary Enclosure material Lens material Maximum sensing distance Output type Add on input Wire insulation material Status
More informationOperating Instructions Differential Pressure Transducer PS27
Operating Instructions Differential Pressure Transducer PS27 halstrup-walcher GmbH Stegener Straße 10 79199 Kirchzarten/Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-mail: info@halstrup-walcher.com
More information4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module electronics
More informationPhone: Fax: Web: -
In automated systems, sensors and actuators must interact with one another functionally and safely. The necessary coordination is performed by the programmable Safety Controller. The controller monitors
More informationInstallation Guide Serial Interface T942SI
Installation Guide 2003-02-8/ Ver. C Contents.... General... 2 Board Description... 2 3 Installation... 4 3. Mounting... 4 3.2 Opening the Housing... 4 3.3 Mounting together with other Units... 5 3.4 Wiring
More informationOnline data sheet WL9LG-3P2232 W9LG-3 SMALL PHOTOELECTRIC SENSORS
Online data sheet WL9LG-3P3 W9LG-3 A B C D E F Illustration may differ Ordering information Type Part no. WL9LG-3P3 05834 Other models and accessories www.sick.com/w9lg-3 H I J K L M N O P R S T Detailed