Digital Viewer With Multiple Pass Memory Part # 1025

Size: px
Start display at page:

Download "Digital Viewer With Multiple Pass Memory Part # 1025"

Transcription

1 2036 Fillmore Street Davenport, Ia Digital Viewer With Multiple Pass Memory Part # 1025 WARRANTY AND DISCLAIMER DIGITAL DELAY INC. WARRANTS THE PRODUCTS IT MANUFACTURES AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD LIMITED TO 1 YEAR FROM THE DATE OF SHIPMENT, PROVIDED THE PRODUCTS HAVE BEEN STORED, HANDLED, INSTALLED, AND USED UNDER PROPER CONDITIONS. The company s liability under this limited warranty shall extend only to the repair or replacement of a defective product, at the company s option. DIGITAL DELAY INC. disclaims all liability for any affirmation, promise, or representation with respect to the products. The customer agrees to hold DIGITAL DELAY INCORPORATED harmless from, defend, and indemnify DIGITAL DELAY INC. against damages, claims, and expenses arising out of subsequent sales of or use of DIGITAL DELAY INC. products, or products containing components manufactured by DIGITAL DELAY INC. and based upon personal injuries, deaths, property damage, lost profits, and other matters which BUYER, its employees, or sub-contractors are or may be to any extent liable, including without limitation, penalties imposed by the Consumer Product Safety Act (P.L ) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty Act (P.L ), as now in effect or as amended hereafter. No warranties expressed or implied, are created with respect to the company s products except those expressly contained herein. The customer acknowledges the disclaimers and limitations contained and relies on no other warranties or affirmations. 1

2 2036 Fillmore Street Davenport, Ia Digital Viewer with Multiple Pass Memory Instructions. The Digital Viewer, part number 1025-DV, comes standard with the ability to store up to 10 passes at one time. With an optional upgrade this number is raised to 40 passes. While the Digital Viewer can be a useful piece of equipment alone, utilizing the printing features of the unit can be a great asset. For example, if a pass recorded by a Digital Delay Mega 400 is printed out in graph form, the top of the printed page will contain several lines of information relating to the settings of the Mega 400. If this page is then stapled to the time slip from the track, a complete record of the pass will be created. A sample print-out from a pass recorded by a Mega 400 is shown on page 6. Contents: Warranty and Disclaimer... Page 1 The Display... Page 3 The Keypad... Page 3 Down-Loading a Pass... Page 4 Viewing a Pass... Page 5 Printing a Pass... Page 5 Erasing Passes... Page 5 Auto Power Off... Page 5 Glossary... Page 6 2

3 The Displays When the Digital Viewer is first turned on, the top display will show the maximum number of passes that can be stored in the unit (10 or 40). The bottom display will show 4 dashes indicating the unit is on and ready to be used. If the displays do not turn on check the battery. The time is always shown on the top display while the corresponding RPM is shown on the bottom display. The displays are also used with the keypad to control all of the functions of the unit. The following is a list of abbreviations and their meanings. 1. LP Load pass 2. PP Print pass 3. -P View pass 4. PL Print length 5. HI Print high resolution graph 6. LI Print numerical list 7. HL Print graph and list 8. HELP There is a problem executing the last instruction 9. EP Erase a pass or all passes The Keypad The keypad is made up of three types of keys, numerical, control, and function. Each key is listed below with an explanation of its function. The Numerical Keys Ten numerical keys 0-9 are used to enter pass numbers after a control key has been pressed. The numerical keys are also used to enter Go To times. The Control Keys The control keys are the three keys at the bottom of the keypad. The left one is Load Pass, this key is used to both store passes in memory, and when used in conjunction with the Go To key, a single pass or all the passes can be erased from memory. The center control key is Print Pass, this key is used when a print-out of a pass is desired. The right control key is View Pass, this key is used to view either a pass stored in memory in the Digital Viewer, or a pass stored in an separate unit that is connected to the Digital Viewer via the Digital Data Port. The Function Keys The rest of the keys are all considered function keys. The following will list each function key along with a description of what it does. If a function key has more than one function, the main function will be listed first with its description followed by the second function and its description. Print Mode The print mode key is only enabled when printing a pass and is used to select one of the three printing modes. This is done by repeatedly pressing the print mode key which will switch to the next mode each time the print mode key is pressed. The default mode is HL which means that a high resolution graph followed by a numerical list will be printed. The other two modes are, HI meaning that only a high resolution graph will be printed and LI meaning that only a numerical list will be printed. Up arrow and Yes The Up Arrow key is used when viewing a pass to either increase the time by a hundredth of a second or to scroll up through the time. This is done by either pressing and releasing the up arrow key which will increase the time by only a hundredth of a second, or by pressing and holding the up arrow key which will start the time to scroll. The scrolling rate will be slow at first, and increase if the up arrow key is continually held down. To go back to the slow scrolling speed, release the up arrow and depress it again. The second function of up arrow is Yes. When either printing or loading a pass the Digital Viewer will always wait until the Yes key is pressed to execute the instruction or the No key to cancel the instruction. 3

4 Down Arrow and No The Down Arrow key is used when viewing a pass to either decrease the time by a hundredth of a second or to scroll down through the time. This is done by either pressing and releasing the down arrow key which will decrease the time by only a hundredth of a second, or by pressing and holding the down arrow key which will start the time to scroll. The scrolling rate will be slow at first, and increase if the down arrow key is continually held down. To go back to the slow scrolling speed, release the down arrow and depress it again. The second function of down arrow is No. When either printing or loading a pass the Digital Viewer will always wait until the Yes key is pressed to execute the instruction or the No key to cancel the instruction. Go To Time and Print Length The Go To Time key is used to jump to a specific time when viewing a pass. This is done by first pressing the Go To Time key while viewing a pass, which will cause the top display to go blank while the number of the pass being viewed is shown on the bottom display. Next use the numerical keys to enter the four digit number representing the desired time. As the numbers are pressed they will be displayed on the top display going from left to right. All leading zeros for the desired time must be entered. If the number entered exceeds fifteen seconds, the Digital Viewer will automatically set the time to fifteen seconds. After the last digit is entered the bottom display will show the RPM corresponding to the time entered. The second function of Go To Time is Print Length. When printing a pass the Print Length Time setting will control how many seconds of information will be printed. The Print Length can be set from one to fifteen seconds, in one second intervals. This is done by repeatedly pressing the Print Length key, each time the key is pressed the print length will increase by one. Once the Print Length has been set it will not change, even if the battery is removed, until a new amount is entered using the Print Length key. Shift Point and Grid The Shift Point key is used to display each shift point, up to a maximum of five, that was recorded during the pass. When viewing a pass that has at least one shift, pressing the Shift Point key will cause the Digital Viewer to display the time that the shift occurred. If the Shift Point key is then pressed again the next shift will be displayed and so on for up to five shifts. Once the last shift is being displayed, the next time the Shift Point key is pressed the first shift time will be redisplayed starting the sequence over again. If no shifts were recorded, pressing the Shift Point key will have no affect. The second function of the Shift Point key is, when printing a pass it controls whether the grid is on or off. When printing a graph with the grid turned on, horizontal lines will be printed for each of RPM listed on the side of the graph. When printing the graph with the grid turned off the horizontal lines will not be printed. This feature works the same when printing a list. Once the grid has been set it will not change, even if the battery is removed, until a new setting on or off is entered using the Grid key. Down-Loading a Pass To down-load a pass, the Digital Viewer must first be connected to another unit via the Digital Data Port. Then press the Load Pass key, the letters LP will be shown on the top display while the bottom display will show the last pass number that was loaded. This can be a helpful reminder. Using the numeric keys enter the desired location to store the pass ( ) or, ( ) for units that have expanded memory. As the numbers are entered they will be shown on the top display. If the two digit number was incorrectly entered press the NO key, this will cancel the down-load. If the two digit number entered is the desired pass number press the YES key. The bottom display will go blank and then as the pass is down-loaded, the bottom screen will show a - for every 25% of information down-loaded. When the down-loading is complete the Digital Viewer will automatically display the beginning of the pass just stored. If HELP is displayed it means the Digital Viewer is having trouble communicating with the other unit. 4

5 Viewing a Pass To view a pass that was previously stored press the View Pass key, the top display will show -P and the bottom display will show the pass number for the last pass stored. This can be helpful reminder. Next using the numeric keys enter the desired pass number, ( ) or ( ) for units that have expanded memory. Once the second digit has been entered the Digital Viewer will display the beginning of the pass. If HELP is displayed when attempting to view a pass it means that there is not any information stored at that location to view. To view a pass without down-loading, connect the Digital Viewer to another unit via the Digital Data Port. Next press the View Pass key then enter 00 for a pass number, this will tell the Digital Viewer to retrieve the information from the other unit. If HELP is displayed when attempting to view a pass from another unit it means either there is no information stored in the other unit or the two units are having trouble communicating with each other. After entering a valid pass number, the time will be shown on the top screen and the starting line RPM will be shown on the bottom screen. At this point the Arrow keys can be used to scroll through the time, the Go To Time key can be used to jump to a specific time, or the Shift Point key can be used to jump to the time that the shifts occurred. Printing a Pass To print a pass the Digital Viewer must be connected to an IBM compatible dot matrix printer via the Digital Printer Port. Then press the Print Pass key, the top display will show the letters PP for print pass and the bottom display will show the last pass number recorded. Next use the numerical keys to enter the number of the pass to be printed. As the numbers are entered they will be shown on the top display. If the two digit number was incorrectly entered press the NO key, this will cancel the printing. Once both numbers have been entered the information on the screens will change. The top display will show the pass to be printed on the left side and the print mode on the right side of the screen. The bottom display shows the print length time and whether the grid line will be printed. The print mode controls in what form the information will be printed. There are three print modes, HL high resolution graph and list, HI high resolution graph only, and LI list only. To change the print mode repeatedly press the Print Mode key until the display shows the desired print mode. The print length controls how many seconds of the pass will be printed. Any number from 1 to 15 can be used. To change the print length repeatedly press the P.L. key until the desired print length time is shown on the bottom display. The print length will affect both the graph and the list length. The grid line can be turned on and off by repeatedly pressing the Grid key. If the grid lines are on the bottom display will show an arrow. Erasing Passes It is not necessary to erase a pass before down-loading a new one to the same location. However from time to time it may be desirable to get rid of old data. This can be done in individually or all at one time. To erase only one pass first press the Load Pass key, then use the numerical keys to enter the pass number to be erased. Next press the Go To Time key, the top display will show EP on the left and the number of the pass to be erased on the right. Press the Yes key to start the erase or press the No key to cancel the erase. To erase all of the passes in memory at once, first press the Load Pass key. Then enter 00 as the pass number followed by pressing the Go To Time key. The top display will show the letters EP and the bottom display will show 1-10 or 1-40 for units with expanded memory. Press the Yes key to start the erase or press the No key to cancel the erase. Auto Power Off The auto power off feature is to conserve battery power when the unit is not being used. If after 2 minutes a key has not been pressed while viewing a pass, the unit will turn itself off. To get the unit to turn back on, turn the power switch off and then back on. 5

6 Glossary Digital Data Cable: A cable that connects the Digital Data Port of the Digital Viewer to the Digital Data port of another unit. Digital Data Port: This is the small connector on the right side of the Digital Viewer that is used when down-loading a pass. Digital Printer Cable: The cable that connects the Digital Printer Port to a printer. Digital Printer Port: This is the large connector on the left side of the Digital Viewer that is used when printing a pass. Expanded Memory: This is an optional up-grade that increases the number of passes the Digital Viewer can hold from 10 to 40. Load Pass: ( Down-Loading ) The act of moving information from one unit to another. Pass Number: A reference number, selected by the user, for the memory slot that pass information is to be stored in. 6

MEGA DIAL PANEL Instructions

MEGA DIAL PANEL Instructions 2036 Fillmore Street Davenport, Ia. 52804 563-324-1046 www.racedigitaldelay.com MEGA DIAL PANEL Instructions WARRANTY AND DISCLAIMER DIGITAL DELAY ELECTRONICS INC. WARRANTS THE PRODUCTS IT MANUFACTURES

More information

MODEL AAMA - UNIVERSAL SIGNAL CONDITIONING MODULE

MODEL AAMA - UNIVERSAL SIGNAL CONDITIONING MODULE Bulletin No. AAMA-G Drawing No. LP0368 Released 05/13 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL AAMA - UNIVERSAL SIGNAL CONDITIONING MODULE 3-WAY ISOLATION OF ANALOG SIGNALS UNIVERSAL

More information

Autotech Controls M7350 Programmable Resolver Decoder Function Modules. Instruction & Operation Manual

Autotech Controls M7350 Programmable Resolver Decoder Function Modules. Instruction & Operation Manual Autotech Controls M7350 Programmable Resolver Decoder Function Modules (ASY-M7350-010 and ASY-M7350-030 Single-Turn and ASY-M7350-020 Multi-Turn) Instruction & Operation Manual Sales and Marketing 343

More information

UNLEASH THE POWER. See More at: bullydog.com WITH BULLY DOG PERFORMANCE PRODUCTS. Doc.# BD43569 v1.0.1

UNLEASH THE POWER. See More at: bullydog.com WITH BULLY DOG PERFORMANCE PRODUCTS. Doc.# BD43569 v1.0.1 Bully Dog Technologies, LLC is a team built on integrity that is dedicated to leading the vehicle performance industry with an uncompromising code of ethics demonstrated in the soundness of its employees,

More information

MODEL BFD - BIG FLEXIBLE DISPLAY

MODEL BFD - BIG FLEXIBLE DISPLAY Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net Bulletin No. BFD-A Drawing No. LP0591 Released 6/05 MODEL BFD - BIG FLEXIBLE DISPLAY LARGE 38.5" (977.9 mm) X 19" (482.6 mm) RED LED DISPLAY

More information

MODEL ICM8 COMMUNICATION GATEWAY

MODEL ICM8 COMMUNICATION GATEWAY Bulletin No. ICM8-A Drawing No. LP0642 Released 1/07 MODEL ICM8 COMMUNICATION GATEWAY COMMUNICATION GATEWAY FOR RED LION PRODUCTS PROTOCOLS AVAILABLE: RS232, RS485 AND ETHERNET PROGRAMMABLE VIA CRIMSON

More information

BuckEye Cam ORION CellBase

BuckEye Cam ORION CellBase BuckEye Cam ORION CellBase Cellular Base for BuckEye Cam ORION Wireless Camera Systems Addendum to Owner's Manual WARRANTY REGISTRATION ATSI warrants Products (BuckEye CamTM ORION CellBase) sold by it

More information

6.0L FORD Power Stroke

6.0L FORD Power Stroke 6.0L FORD Power Stroke Exhaust Outlook Monitor Intake Modules OPERATING Instructions Thank You & Enjoy! For Free Technical Support Call (208) 397-3200 1 10 REMEMBER THIS IS A PERFORMANCE PRODUCT USE AT

More information

R52 Top Commander. Installation and Configuration Guide. 325 Sharon Park Dr. #652. Menlo Park, CA USA (650)

R52 Top Commander. Installation and Configuration Guide. 325 Sharon Park Dr. #652. Menlo Park, CA USA (650) R52 Top Commander Installation and Configuration Guide 325 Sharon Park Dr. #652 Menlo Park, CA 94025 USA (650) 241-1161 www.fes-auto.com R52 Top Commander Installation Guide Page 2 Table of Contents Chapter

More information

BM32 Button Module User Guide

BM32 Button Module User Guide BM3 Button Module User Guide 16-601450 Issue 1 April 007 007 Avaya Inc. All Rights Reserved. Notice While reasonable efforts were made to ensure that the information in this document was complete and accurate

More information

Installing Your Microsoft Access Database (Manual Installation Instructions)

Installing Your Microsoft Access Database (Manual Installation Instructions) Installing Your Microsoft Access Database (Manual Installation Instructions) Installation and Setup Instructions... 1 Single User Setup... 1 Multiple User Setup... 2 Adjusting Microsoft Access 2003 Macro

More information

CR87B TEMPERATURE RECORDER

CR87B TEMPERATURE RECORDER CR87B TEMPERATURE RECORDER Sealed Unit Parts Co., inc. PO Box 21, 2230 Landmark Place, Allenwood, NJ 08720 USA Phone: 732-223-6644 Fax: 732-223-1617 www.supco.com info@supco.com 19204 INTRODUCTION The

More information

INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH

INSTALLATION INSTRUCTIONS 5 SINGLE CHANNEL ULTIMATE TACH Instr. No. 2650-887C INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH MODEL 6871, 6872, 6873, 6874, 6875, 6877 IMPORTANT WEAR SAFETY GLASSES 5 4 6 COPYRIGHT PATENT PENDING 3 7 8 PLAYBACK 9 2 0

More information

Autotech Controls M8000-D360T Resolver Decoder Input Module Instruction & Operation Manual

Autotech Controls M8000-D360T Resolver Decoder Input Module Instruction & Operation Manual Autotech Controls M8000-D360T Resolver Decoder Input Module Instruction & Operation Manual AVG Automation Autotech Controls 343 St. Paul Boulevard Carol Stream, IL 60188 Telephone: 630-668-3900 800-TEC-ENGR

More information

Superchips 1705 MAX MicroTuner Ford Powerstroke 7.3L Turbo Diesel Vehicles Vehicle Programming Instructions

Superchips 1705 MAX MicroTuner Ford Powerstroke 7.3L Turbo Diesel Vehicles Vehicle Programming Instructions Page 1 of 12 Form 0126K 10/26/2004 Superchips Inc. Superchips 1705 MAX MicroTuner Ford Powerstroke 7.3L Turbo Diesel Vehicles Vehicle Programming Instructions PLEASE READ THIS ENTIRE INSTRUCTION SHEET

More information

GX-6000 Data Logger Management Program Operator s Manual

GX-6000 Data Logger Management Program Operator s Manual GX-6000 Data Logger Management Program Operator s Manual Part Number: 71-0383 Revision: B Released: 7/27/17 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us

More information

PixController, Inc. Wireless Magnetic Switch Sensor For Doors, Windows, and Gates

PixController, Inc. Wireless Magnetic Switch Sensor For Doors, Windows, and Gates PixController, Inc. Wireless Magnetic Switch Sensor For Doors, Windows, and Gates Model: SEN-420 User s Manual Version 1.00 WARRANTY REGISTRATION PixController, Inc. warrants products sold by it and guarantees

More information

The Check-in Call How-to Guide

The Check-in Call How-to Guide The Check-in Call How-to Guide Welcome to The Check-in Call. Thank you for choosing GreatCall s Check-in Call service. We ve designed this service so that you and your loved ones can enjoy the peace of

More information

Hardware Documentation

Hardware Documentation Hardware Documentation for JTAG Debug Adapter Version 1.0 2014-12-02 F&S Elektronik Systeme GmbH Untere Waldplätze 23 D-70569 Stuttgart Fon: +49(0)711-123722-0 Fax: +49(0)711 123722-99 History Date V Platform

More information

PixController, Inc. Wireless Switch Sensor For Normally Open (NO) and Normally Closed (NC) Sensors

PixController, Inc. Wireless Switch Sensor For Normally Open (NO) and Normally Closed (NC) Sensors PixController, Inc. Wireless Switch Sensor For Normally Open (NO) and Normally Closed (NC) Sensors Model: SEN-410 User s Manual Version 1.00 WARRANTY REGISTRATION PixController, Inc. warrants products

More information

Redirector User Guide

Redirector User Guide Redirector User Guide Revision B November 04, 2005 Part Number GC-800-235 Copyright and Trademark Copyright 2004, Grid Connect, Inc. All rights reserved. No part of this manual may be reproduced or transmitted

More information

XS/SC26-2 Safety Controller. Quick Start Guide

XS/SC26-2 Safety Controller. Quick Start Guide XS/SC26-2 Safety Controller Quick Start Guide Original Instructions 174869 Rev. C 16 January 2015 1 THIS PAGE IS INTENTIONALLY LEFT BLANK ABOUT THIS GUIDE This guide is designed to help you create a sample

More information

Automator (Standard)

Automator (Standard) Automator (Standard) DLL Users Guide Available exclusively from PC Control Ltd. www.pc-control.co.uk 2017 Copyright PC Control Ltd. Revision 1.2 Contents 1. Introduction 2. DLL Reference 3. Using the DLL

More information

16xx/96xx Amplified Speech Handset Installation and Use

16xx/96xx Amplified Speech Handset Installation and Use 16xx/96xx Amplified Speech Handset Installation and Use 16-602703 Issue 1 July 2008 2008 Avaya Inc. All Rights Reserved. Notice While reasonable efforts were made to ensure that the information in this

More information

GOCO.IO, INC TERMS OF SERVICE

GOCO.IO, INC TERMS OF SERVICE GOCO.IO, INC TERMS OF SERVICE GoCo.io, Inc. ("GoCo", the "Site", "https://www.goco.io") welcomes you! GoCo provides services to you subject of the following terms of service (the "Agreement"). The Agreement

More information

CONTENTS CONTENTS AWS-4050 Guide

CONTENTS CONTENTS AWS-4050 Guide CONTENTS 1 CONTENTS CONTENTS...1 INTRODUCTION...2 Description...2 System Specifications...2 OPERATION...3 Display Operation...3 nction...4 Back Panel Inputs...4 Transducer Input (12-pin connector)...4

More information

Model A7BS

Model A7BS Thumbwheel Switch ABS/ABL CSM_ABS/ABL_DS_E Wide Range of Locking-type s Available Character height of.8 or. mm makes for easy-toview display. Installation is easy with snap-in mounting. The series includes

More information

KEYPAD MODEL USER MANUAL

KEYPAD MODEL USER MANUAL KEYPAD MODEL USER MANUAL Contents SecureDrive Overview 3 Safety Information 3 SecureDrive Features 4 PINs and Procedures 5 User Mode 5 User PINs 5 Unlocking the Drive in User Mode 6 Changing the User PIN

More information

Multiple-User Mode Operating Guide for Lock Models 2006 and 2007

Multiple-User Mode Operating Guide for Lock Models 2006 and 2007 Page 1 of 1 Multiple-User Mode Operating Guide for Lock Models 2006 and 2007 Change from Multiple-User to Dual-User This non-reversible function change must be done before the factory Master Code is changed

More information

DATE ( / 7. / 1. / / 3. / / 5. / 6. / TIME

DATE ( / 7. / 1. / / 3. / / 5. / 6. / TIME ELIMINATOR 2000 INSTRUCTIONS Table of Contents 1. PRACTICE A. TREE Key 1. Change Full to Pro Tree 2. Change Tree Speed ( 4 tenths or 5 tenths) 3. Change Rollout Out Separate Full and Pro Tree 4. Change

More information

ETConcept Systems Engineering. User s Guide

ETConcept Systems Engineering. User s Guide Wiegand to RS485 Converter User s Guide Nov-08 Copyright 2008. All rights reserved including the right of reproduction in whole or in part in any form. Contents List of Accessories Included... 1 List

More information

Font Tool User Guide. Abstract. Document Date: 1 July 2009 Document Revision: 01

Font Tool User Guide. Abstract. Document Date: 1 July 2009 Document Revision: 01 Document Date: 1 July 2009 Document Revision: 01 Abstract This User guide explains Font Tool software in detail. Font Tool will assist the user in converting Windows fonts (including true type) into the

More information

SC-01 Data Logger Management Program Operator s Manual

SC-01 Data Logger Management Program Operator s Manual SC-01 Data Logger Management Program Operator s Manual Part Number: 71-0138RK Revision: P1 Released: 9/12/07 www.rkiinstruments.com Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by

More information

REMOTE FRONT PANEL EMULATION

REMOTE FRONT PANEL EMULATION REMOTE FRONT PANEL EMULATION USER REFERENCE GUIDE 2500 Application Software Series Part Number: 3-9003-170 Revision 1.0 MARCH 1991 EMULATOR GUIDE DANIEL INDUSTRIES, INC. REMOTE FRONT PANEL EMULATION USER

More information

AWS-3000 Torque Display

AWS-3000 Torque Display AWS-3000 Torque Display USER'S GUIDE February, 2008 AWS-5000 Shown with External Input Connector ADVANCED WITNESS SERIES, INC. 910 BERN COURT #100 SAN JOSE, CA 95112 (408) 453-5070 www.awitness.com CONTENTS

More information

use. Best of all, the is affordable and will keep you in touch with those important to you.

use. Best of all, the is affordable and will keep you in touch with those important to you. Congratulations on your purchase of our Pager. By incorporating some of the most advanced electronic paging technologies, the is reliable and easy to use. Best of all, the is affordable and will keep you

More information

USB-A to Serial Cable

USB-A to Serial Cable 26-949 User s Guide 6-Foot (1.82m) USB-A to Serial Cable Please read this user s guide before using your new cable. 2/2 Package contents USB-A to Serial Cable User s Guide Driver CD Quick Start Features

More information

Quick Start Installation Guide

Quick Start Installation Guide Quick Start Installation Guide Table of Contents 1. Introduction... 3 2. System Installation... 3 3. System Programming... 5 3.1. Keys Menu Navigation... 5 3.2. Enter Engineer Programming mode... 5 3.3.

More information

APPLICATION NOTE. Application Note: 4D-AN-P4004. ViSi-Genie Advanced Buttons. Document Date: November 15 th, Document Revision: 1.

APPLICATION NOTE. Application Note: 4D-AN-P4004. ViSi-Genie Advanced Buttons. Document Date: November 15 th, Document Revision: 1. APPLICATION NOTE Application Note: ViSi-Genie Advanced Buttons Document Date: November 15 th, 2012 Document Revision: 1.0 Description This Application Note explores the possibilities provided by ViSi-Genie

More information

GX-2009 Data Logger Management Program Operator s Manual

GX-2009 Data Logger Management Program Operator s Manual GX-2009 Data Logger Management Program Operator s Manual Part Number: 71-0163RK Revision: E Released: 4/14/17 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by

More information

SafePace 600 Variable Messaging Sign

SafePace 600 Variable Messaging Sign SafePace 600 Variable Messaging Sign The new Traffic Logix SafePace 600 variable messaging sign is a versatile and full featured radar speed solution. Whether you want to simply alert drivers of their

More information

BACNet Gateway Option

BACNet Gateway Option INSTRUCTION MANUAL MultiGard 5000 System Integration BACNet Gateway Option 1-800-MSA-INST or FAX (724) 776-8783 MSA International (412) 967-3354 or FAX (412) 967-3451 In Canada 1-800-267-0672 or FAX (416)

More information

PIC32 SK I/O Breakout Board. User Manual

PIC32 SK I/O Breakout Board. User Manual PIC32 SK I/O Breakout Board The PIC32 SK I/O Breakout board is a practical and useful board to let you develop your PIC32 Starter Kit application without the design of additional PCBs, thanks to the breakout

More information

Internet Service Provider Agreement

Internet Service Provider Agreement Internet Service Provider Agreement 1. Introduction By using this Internet service ( Service ) you agree to be bound by this Agreement and to use the Service in compliance with this Agreement, our Acceptable

More information

Workshop 4 Installation INSTALL GUIDE. Document Date: February 4 th, Document Revision: 1.1

Workshop 4 Installation INSTALL GUIDE. Document Date: February 4 th, Document Revision: 1.1 INSTALL GUIDE Workshop 4 Installation Document Date: February 4 th, 2013 Document Revision: 1.1 Description This document describes how to install and configure Workshop 4, and how to install the driver

More information

INTELLITAPE USERS MANUAL. Intellitape USERS MANUAL Chief Automotive Technologies, Inc.

INTELLITAPE USERS MANUAL. Intellitape USERS MANUAL Chief Automotive Technologies, Inc. Intellitape 0 2008 Chief Automotive Technologies, Inc. Table of Contents Intellitape Limited Warranty Agreement... 2 Hardware... 3 Button Configuration... 3 Operation... 3 As a stand alone device:... 3

More information

Avaya Groupware Edition for IBM Lotus Help

Avaya Groupware Edition for IBM Lotus Help Avaya Groupware Edition for IBM Lotus Help Table of Contents Welcome to Groupware Edition for IBM Lotus Help...4 Overview...5 What is Groupware Edition for IBM Lotus?...5 Where is Groupware Edition located

More information

LCD62. Keypad. User Manual

LCD62. Keypad. User Manual LCD62 Keypad User Manual Disclaimer: While every effort has been made to ensure that the information in this manual is accurate and complete, no liability can be accepted for any errors or omissions The

More information

Model GX-2001 Data Logging Software. User s Guide

Model GX-2001 Data Logging Software. User s Guide Model GX-2001 Data Logging Software User s Guide Part Number: 71-0056RK Edition: First Released: 6/29/2001 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects

More information

ARROW 3. TRACK A. 4. DISPLAY

ARROW 3. TRACK A. 4. DISPLAY ELIMINATOR 2000 INSTRUCTIONS Table of Contents 1. PRACTICE A. TREE Key 1. Change Full to Pro Tree 2. Change Tree Speed (4 tenths or 5 tenths) 3. Change Top Bulb Lock (Cross Talk) On / Off 4. Change Rollout

More information

Single Cell Battery Power Solution

Single Cell Battery Power Solution Single Cell Battery Power Solution Input 5V DC Output 2.80.. 4.28V (dependent on charge state of battery) Current limited to 500mA max. Devices TPS2113A Autoswitching Power MUX TPD4S012 4-Channel USB ESD

More information

Terms & Conditions governing Samsung Smartphone Bundle Offer ( Offer ):

Terms & Conditions governing Samsung Smartphone Bundle Offer ( Offer ): Terms & Conditions governing Samsung Smartphone Bundle Offer ( Offer ): THIS DOCUMENT IS AN ELECTRONIC RECORD IN TERMS OF THE INFORMATION TECHNOLOGY ACT, 2000 AND RULES THERE UNDER AS APPLICABLE. THIS

More information

FLUENDO GENERIC EULA

FLUENDO GENERIC EULA FLUENDO GENERIC EULA FLUENDO S.A. Avenida Diagonal 579, 8th floor 08014 Barcelona Spain 1 END USER LICENSE AGREEMENT (EULA) FLUENDO LICENSE AGREEMENT BY FLUENDO, S.A. ( FLUENDO ) IMPORTANT - READ CAREFULLY

More information

DPOS SQL Stocktake Guide ADVANPOS Till Stocktake Scanners BHT300B

DPOS SQL Stocktake Guide ADVANPOS Till Stocktake Scanners BHT300B Retail & Sports Systems Limited Sales Tel: 0845 258 1088 / 0115 871 9451 Support Tel: 0845 258 1889 / 0115 871 9450 www.retailsportssystems.co.uk Registered Office: 32 Turney Street, Nottingham NG2 2LG

More information

MODEL ITMA - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUT

MODEL ITMA - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUT Bulletin No. ITMA-D Drawing No. LP082 Released 1/07 Tel +1 (717) 767-6511 Fax +1 (717) 764-089 www.redlion.net MODEL ITMA - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUT USER PROGRAMMABLE INPUT (Thermocouple

More information

Certifications (regional):

Certifications (regional): Certifications (regional): Z-Wave and Z-Wave Plus are registered trademarks of Sigma Designs and its subsidiaries in the United States and other countries Version:501008800001-AB www.aeotec.com View the

More information

Williamsburg Multiple Listing Service, Inc. SENTRILOCK SERVICE AGREEMENT

Williamsburg Multiple Listing Service, Inc. SENTRILOCK SERVICE AGREEMENT FORM 118 Williamsburg Multiple Listing Service, Inc. SENTRILOCK SERVICE AGREEMENT THIS SENTRILOCK SERVICE AGREEMENT (the Agreement ) is entered into as of the day of, 20, by and between the Williamsburg

More information

WEBSITE DESIGN CONTRACT RECITALS AGREEMENT

WEBSITE DESIGN CONTRACT RECITALS AGREEMENT WEBSITE DESIGN CONTRACT We are delighted that you have selected Wards Enterprise Web Design, Inc. for your website design needs! We look forward to working with you on this exciting project. In order to

More information

Bluetooth USB User Guide. Revision A July 12, 2006 Part Number GC

Bluetooth USB User Guide. Revision A July 12, 2006 Part Number GC Bluetooth USB User Guide Revision A July 12, 2006 Part Number GC-800-316 Copyright and Trademark Copyright 2005, Grid Connect, Inc. All rights reserved. No part of this manual may be reproduced or transmitted

More information

Remote Refrigeration Control

Remote Refrigeration Control Remote Refrigeration Control Installation & Operation Bulletin No. H-IM-RRC June 2018 Part Number 25092901 Replaces H-IM-RRC (01/17) Remote Refrigeration Control Installation Start Up Troubleshooting Operation

More information

Durant Eclipse Series Digital Panel Meters Durant Durant Visit our Web Site at

Durant Eclipse Series Digital Panel Meters Durant Durant Visit our Web Site at Eclipse Series Digital Panel Meters Installation and Operation Manual Number 57700-900-05 Models: 5770X-40X - DC Volts 5770X-4X - AC Volts 5770X-42X - DC Amps 5770X-43X - AC Amps 5770X-44X - 5A AC 5770X-45X

More information

REQUESTING EMERGENCY SERVICES. MDS AMIBA TERMS OF SERVICE Welcome to MDS AMIBA Broadband Phone Service. THESE TERMS AND CONDITIONS STATE IMPORTANT

REQUESTING EMERGENCY SERVICES. MDS AMIBA TERMS OF SERVICE Welcome to MDS AMIBA Broadband Phone Service. THESE TERMS AND CONDITIONS STATE IMPORTANT REQUESTING EMERGENCY SERVICES. MDS AMIBA TERMS OF SERVICE Welcome to MDS AMIBA Broadband Phone Service. THESE TERMS AND CONDITIONS STATE IMPORTANT REQUIREMENTS REGARDING YOUR USE OF MDS AMIBA BROADBAND

More information

M.2 Carrier Card. Installation Guide. Revision 1.0

M.2 Carrier Card. Installation Guide. Revision 1.0 BPN-ADP-2M2-1UB M.2 Carrier Card Installation Guide Revision 1.0 The information in this User s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for

More information

SLUG DATA-LOGGER MANUAL. YieldPoint Inc. JULY 2009

SLUG DATA-LOGGER MANUAL. YieldPoint Inc. JULY 2009 SLUG DATA-LOGGER MANUAL YieldPoint Inc. JULY 2009 Copyright 2009 by YieldPoint Inc. The Information contained herein is the exclusive property of YieldPoint Inc., except as otherwise indicated and shall

More information

2005: 0.5 PQ-MDS-PCIEXP

2005: 0.5 PQ-MDS-PCIEXP HW Getting Started Guide PQ-MDS-PCIEXP Adaptor December 2005: Rev 0.5 PQ-MDS-PCIEXP Adaptor HW Getting Started Guide Step 1:Check HW kit contents 1.PQ-MDS-PCIEXP Adaptor 2.PIB (Platform I/O Board) to PCIEXP

More information

SkyNanny 1.0 Quick Start Guide Version 1.01

SkyNanny 1.0 Quick Start Guide Version 1.01 SkyNanny 1.0 Quick Start Guide Version 1.01 Copyright (c) 2014 Neit Enterprises Inc. Page 1 1 First Time Use - Charge the battery Prior to first-time use, please charge the battery 8 to 12 hours in the

More information

XS/SC26-2 Safety Controller Quick Start Guide

XS/SC26-2 Safety Controller Quick Start Guide XS/SC26-2 Safety Controller Quick Start Guide About this Guide This guide is designed to help you create a sample configuration for the XS/SC26-2 Safety Controller using the XS26-2 Expandable Safety Controller

More information

RATIO CONTROLLER HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION NOTE DESCRIPTION SPECIFICATION

RATIO CONTROLLER HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION NOTE DESCRIPTION SPECIFICATION RATIO CONTROLLER TECHNICAL DATA MODEL SIZE MAX. SERVICE PRESSURE FACTORY HYDRO TEST PRESSURE MOUNTING APPROVAL FINISH ORDERING INFORMATION DESCRIPTION Bronze Construction:- RCW-B, RCW-BM RCF-B, RCF-BM

More information

03 Series Data Logger Management Program Operator s Manual

03 Series Data Logger Management Program Operator s Manual 03 Series Data Logger Management Program Operator s Manual Part Number: 71-0323 Revision: P2 Released: 11/25/14 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by

More information

Business Rebates TRADE ALLY TRAINING MANUAL

Business Rebates TRADE ALLY TRAINING MANUAL Business Rebates TRADE ALLY TRAINING MANUAL Table of Contents Account Access...3 How to Claim Your Account... 3 Prescriptive Program Overview...6 Log-In... 6 Application Pre-Approval Process... 7 Project

More information

APPLICATION NOTE. Application Note: 4D-AN-P4007. ViSi-Genie Play Video. Document Date: November 15 th, Document Revision: 1.

APPLICATION NOTE. Application Note: 4D-AN-P4007. ViSi-Genie Play Video. Document Date: November 15 th, Document Revision: 1. APPLICATION NOTE Application Note: ViSi-Genie Play Video Document Date: November 15 th, 2012 Document Revision: 1.0 Description This Application Note explores the possibilities provided by ViSi-Genie for

More information

The merisuite CG Application

The merisuite CG Application The merisuite CG Application Copyright 2017 Meriam Content The merisuite CG Application...1 Content... 2 General information...3 Notification Statements... 3 Disclaimer... 3 Glossary... 4 Features...5

More information

4. Save as expressly set out herein no license is granted in respect of any intellectual property rights vested in F1000 or other third parties.

4. Save as expressly set out herein no license is granted in respect of any intellectual property rights vested in F1000 or other third parties. Legal information The website F1000.com is operated by Faculty of 1000 Limited, a company registered in England and Wales with Company Number 3739756, with registered offices at Middlesex House, 34-42

More information

OPERATION MANUAL BO BLASTER S OHMMETER

OPERATION MANUAL BO BLASTER S OHMMETER OPERATION MANUAL for the BO1999-10 BLASTER S OHMMETER SEE PAGE 6 FOR USER INFORMATION AND LIMITED WARRANTY RESEARCH ENERGY OF OHIO, INC. 200 East Bluegrass Drive Norwalk, OH 44857 Phone: 419-660-8832 Fax:

More information

You may use the Service to either access, establish or change the following:

You may use the Service to either access, establish or change the following: Online Access Agreement June 18, 2015 (Revision date) I. Introduction This Online Access Agreement (this "Agreement") contains the terms that govern your use of the Participants' Private Area of the www.afmsagaftrafund.org

More information

Micro Tuner Model RaceME Pro Common Rail Dodge Ram 6.7L, 24 Valve, Cummins Diesel Engine. Instruction Manual

Micro Tuner Model RaceME Pro Common Rail Dodge Ram 6.7L, 24 Valve, Cummins Diesel Engine. Instruction Manual Micro Tuner Model RaceME Pro Common Rail Dodge Ram 6.7L, 24 Valve, Cummins Diesel Engine Instruction Manual PLEASE READ THIS ENTIRE INSTRUCTION MANUAL BEFORE PROCEEDING www.racemecanada.com Rev. 1.00A

More information

Application Guide. M 2174B Moloney Replacement Adapter Panel

Application Guide. M 2174B Moloney Replacement Adapter Panel Application Guide M 174B Moloney Replacement Adapter Panel CONTROLS Replacement Panel M 174B Adapts M 001 Series Digital Tapchanger Control to Replace Moloney/Tempo LTC Control Panel Connects easily to

More information

Introduction. Contents

Introduction. Contents Introduction TrekView is a cost-effective temperature recorder that indicates if your product has been exposed to unacceptable temperatures that could negatively affect product quality or safety. TrekView

More information

User Manual TLS HDMI Switch Splitter 3/2

User Manual TLS HDMI Switch Splitter 3/2 875224 User Manual TLS HDMI Switch Splitter 3/2 IR SW B A 3 2 1 HDMI IN HDMI OUT DC 5V 1 2 3 A B 8 875224 HDMI Switch Splitter 3/2 Thank you for purchasing this product. For optimum performance and safety,

More information

Terms and Conditions For Online-Payments

Terms and Conditions For Online-Payments Terms and Conditions For Online-Payments The Terms and Conditions contained herein shall apply to any person ( User ) using the services of Ghaziabad Nagar Nigam for making Tax payments through an online

More information

Intel Cache Acceleration Software for Windows* Workstation

Intel Cache Acceleration Software for Windows* Workstation Intel Cache Acceleration Software for Windows* Workstation Release 3.1 Release Notes July 8, 2016 Revision 1.3 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS

More information

STAINLESS STEEL CAST FITTINGS 150lb 304 & 316 Stainless Steel Cast Fittings Specifications

STAINLESS STEEL CAST FITTINGS 150lb 304 & 316 Stainless Steel Cast Fittings Specifications STAINLESS STEEL CAST FITTINGS 150lb 304 & 316 Stainless Steel Cast Fittings Specifications Manufactured in ISO9000:2000 Facility Items Conform to AISI 304 / 316 Investment Cast SP114 Stainless Fittings

More information

Mobile Wallet Service Terms and Conditions

Mobile Wallet Service Terms and Conditions Mobile Wallet Service Terms and Conditions These Terms and Conditions govern your use of eligible debit or credit cards issued by Publix Employees Federal Credit Union (each, a "Payment Card") when you

More information

QUICK START GUIDE.

QUICK START GUIDE. QUICK START GUIDE www.speedcheetah.com Thank you for purchasing the Cheetah C550. You made a smart choice! The Cheetah C550 is a GPS driver safety system to help protect you and your family, as well as

More information

AARDVARK. EEPROM Socket Board. DIP/SOIC/TSSOP EEPROM Socket Board. Datasheet v1.10 February 1, 2010 I 2 C/SPI. Features

AARDVARK. EEPROM Socket Board. DIP/SOIC/TSSOP EEPROM Socket Board. Datasheet v1.10 February 1, 2010 I 2 C/SPI. Features EEPROM Socket Board Features Programming of stand-alone I 2 C- and SPI-based EEPROM memory chips DIP-8 socket SOIC-8 socket TSSOP-8 socket Multiple voltage options Multiple SPI Slave Select options AARDVARK

More information

DATASHEET 4D SYSTEMS. 4D Raspberry Pi Serial Adaptor TURNING TECHNOLOGY INTO ART. 4D-Serial-Pi-Adaptor

DATASHEET 4D SYSTEMS. 4D Raspberry Pi Serial Adaptor TURNING TECHNOLOGY INTO ART. 4D-Serial-Pi-Adaptor TURNING TECHNOLOGY INTO ART DATASHEET 4D-Serial-Pi-Adaptor Document Date: 20 th November 2012 Document Revision: 1.0 Uncontrolled Copy when printed or downloaded. Please refer to the 4D Systems website

More information

FTC-200 X-ray Tube Controller Users Manual

FTC-200 X-ray Tube Controller Users Manual Tubes FTC-200 X-ray Tube Controller TUB-MAN-2101 Rev. A 09/09/2009TTUB Table of Contents List of Tables...3 List of Figures...3 Introduction...3 Manual Set...3 About this Manual...4 X-Ray Safety Information...4

More information

DATASHEET 4D SYSTEMS. 4D Arduino Adaptor Shield TURNING TECHNOLOGY INTO ART. 4Display-Adaptor-Shield

DATASHEET 4D SYSTEMS. 4D Arduino Adaptor Shield TURNING TECHNOLOGY INTO ART. 4Display-Adaptor-Shield TURNING TECHNOLOGY INTO ART DATASHEET 4Display-Adaptor-Shield Document Date: 20 th November 2012 Document Revision: 1.0 Uncontrolled Copy when printed or downloaded. Please refer to the 4D Systems website

More information

YOUR REPRESENTATIVE IS:

YOUR REPRESENTATIVE IS: INTRODUCTION Welcome to Wycom Welcome to the Wycom family of automated check signing equipment. We have made a great effort to create a product that efficiently and effectively meets your automated check

More information

GEMINI DIGIT PRESETTABLE BATCH COUNTER

GEMINI DIGIT PRESETTABLE BATCH COUNTER Bulletin No. GEM33-C Drawing No. LP0339 Released 1/05 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net GEMINI 3300-6-DIGIT PRESETTABLE BATCH COUNTER! ACCEPTS INPUT COUNT RATES UP TO 10 KHz!

More information

TB-100 ControLynx Terminal Block

TB-100 ControLynx Terminal Block TB-100 ControLynx Terminal Block TECHNICAL MANUAL Version 1.3 September 2006 Copyright This technical manual and the equipment, firmware and software described herein are copyrighted by INTENT DIGITAL

More information

DATASHEET 4D SYSTEMS. 4D Raspberry Pi Serial Adaptor TURNING TECHNOLOGY INTO ART. 4D-Serial-Pi-Adaptor

DATASHEET 4D SYSTEMS. 4D Raspberry Pi Serial Adaptor TURNING TECHNOLOGY INTO ART. 4D-Serial-Pi-Adaptor DATASHEET TURNING TECHNOLOGY INTO ART 4D Raspberry Pi Serial Adaptor 4D-Serial-Pi-Adaptor Document Date: 4 th September 2013 Document Revision: 1.1 Uncontrolled Copy when printed or downloaded. Please

More information

ADW Series Torque Wrench Users Guide for Basic Model with Memory

ADW Series Torque Wrench Users Guide for Basic Model with Memory ADW Series Torque Wrench Users Guide for Basic Model with Memory PO Box 16460, Portland, OR 97292-0460 503-254-6600 Fax 503-255-2615 www.aimco-global.com CONTENTS 2 CONTENTS... 2 INTRODUCTION... 3 Description...

More information

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2 Thumbwheel Switch ABS/ABL CSM_ABS_ABL_DS_E Wide Range of Locking-type s Available Character height of. or. mm makes for easy-toview display. Installation is easy with snap-in mounting. The series includes

More information

Macon Plastics, Inc. Solvent Weld SCH 40/80 DWV

Macon Plastics, Inc. Solvent Weld SCH 40/80 DWV Catalog #210SDWV MP Macon Plastics, Inc. & DWV Fittings P R I C E L I S T Solvent Weld /80 DWV Effective Date: 02/02/15 Catalog : 210SDWV Revision: D Supercedes: 209SDWV Not sure if you have a current

More information

Zikodrive ZD10LCD Stepper Motor Controller (Pump Mode) Quick Start Guide and User Manual

Zikodrive ZD10LCD Stepper Motor Controller (Pump Mode) Quick Start Guide and User Manual 1 Zikodrive ZD10LCD Stepper Motor Controller (Pump Mode) Quick Start Guide and User Manual 2 Contents IMPORTANT NOTE.3 Introduction... 4 Overview... 4 Specifications... 5 Components... 6 Top View... 6

More information

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detection Relay And Probe Revision 8.1 Change Log: Rev 8.1 Apr 24 2012 JNesbitt@GPS-US.co GPS updates

More information

Alamo Ag Customer Service Interface Guide

Alamo Ag Customer Service Interface Guide Alamo Ag Customer Service Interface Guide - Rev 12/2014 2 Contents Logging On...4 Request Access 5 Opening Screen.6 What s New Screen.8 Edit Profile.10 E-Parts Look-up.12 Navigation Tree.14 Product Line/Printable

More information

Avaya Meeting Exchange for IBM Lotus Notes and Sametime Release User Guide

Avaya Meeting Exchange for IBM Lotus Notes and Sametime Release User Guide Avaya Meeting Exchange for IBM Lotus Notes and Sametime Release 1.0.5 User Guide Document No. 17-300735 Release 1.0.5 February 2007 Issue 2 2007 Avaya Inc. All Rights Reserved. This document contains information

More information

AWS-QC Torque Tester

AWS-QC Torque Tester AWS-QC Torque Tester USER'S GUIDE March, 2009 ADVANCED WITNESS SERIES, INC. 910 BERN COURT #100 SAN JOSE, CA 95112 (408) 453-5070 www.awitness.com CONTENTS 1 CONTENTS CONTENTS... 1 INTRODUCTION... 2 Description...

More information