International Edition, Rev. C8

Size: px
Start display at page:

Download "International Edition, Rev. C8"

Transcription

1 International Edition, Rev. C8

2 Revision History Rev. No. Released Date Description Rev. A May 6, First Release Rev. A Jun. 8, Add Symbology Reading Control - UPC/EAN Security Level. Modify Operation Control - "Time Delay to Low Power Mode" Rev. A Sep. 6, Add Symbology Reading Control - Supplement Scan Voting and EAN Supplement Control Modify Keyboard Interface Control Keyboard Layout (Language) Setting Remove Operation Control - Power On Indicator and add Good Read Indicator. Add Operation Control - Scan Rate Control and Good Read Indicator Add Operation Control - NG Message Output Rev. A Nov, Modify Serial Interface Control Baud Rate Rev. A4 Mar 4, Modify Serial Interface Control Baud Rate. Rev. A5 Mar, Modify Symbology Reading Control - Code 9 Setting Modify Serial Interface Control Protocol, ACK/NAK Setting Rev. A6 Jul, Rename Symbology Reading Control - UCC/EAN-8 to GS-8 Rename Serial Interface Control ACK/NAK Transmission Indication to ACK Indication Modify Serial Interface Control ACK Indication and Serial response time -out. Rev. A7 Nov 4, Modify Symbology Reading Control - Codabar/ NW-7 Setting Rev.A8 Mar 9, Add Operation Control - "D Barcode Forward-reading Indication, D Barcode Backward-reading Indication, D Barcode Direction Indication Transmission and Lateral Reading.

3 Revision History Rev. No. Released Date Description Rev.A9 Jul 5, Add Host Interface Selection USB HID Legacy Modify Symbology Reading Control - Code 8 Setting Rev. B Aug, Modify Symbology Reading Control - Readable Bar Code Setting Modify Appendix - Symbology ID Table Rev. C Mar. 4 Support D Functions Rev. C Jun, 4 Modify Operation Control - Illumination Control. Modify Operation Control - Reread Delay Rev. C Feb. 6, 5 Modify Symbology Reading Control - MaxiCode Setting Rev. C4 Dec., 5 Update Revision History Rev. C5 Aug. 4, 6 Add Symbology Reading Control - Small DM Code Reading Rev. C6 Oct. 4, 6 Add Operation Control - Buzzer Volume. Rev. C7 Rev. C8 Oct., 6 Mar. 9, 7 Modify Operation Control - Buzzer Tone Adjust Modify Operation Control - Lateral Reading Modify Operation Control - Buzzer Tone Adjust Remove Operation Control - Dollar Sign to Keyboard Interface Control - Dollar Sign Control

4 Copyright Cino Group Copyright PC Worth Int l Co., Ltd Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied, reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written permission of Cino. All product information and specifications shown in this document may be changed without prior notice. Warranty Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino s control, such as, but not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA procedures to return Cino for inspection.

5 Regulatory FCC part 5B EN55, EN554, EN6--, EN6--, CNS48 Industry Canada ICES- Clause, Article 58- of Radio Waves Act. VCCI, TECHNICAL REQUIREMENTS, Class B ITE LED Eye Safety IEC647 Exempt group

6 Table of Contents Getting Started Getting Familiar with Your FuzzyScan Connect to Your Host Install Your FuzzyScan Intelli Button 4 Use Your FuzzyScan 5 Configure Your FuzzyScan Bar Code 8 Programming Procedures 9 Host Interface Selection Symbology Reading Control 4 Keyboard Interface Control 45 Serial Interface Control 5 Operation Control 54 Condensed DataWizard 69 Appendix Symbology ID Table 77 Keyboard Function Code Table 79 ASCII Input Shortcut 8 Host Interface Quick Set 8 Operation Mode Quick Set 8 Option Codes 8 System Commands 84 Indications 85

7 Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Fixed Mount Scanner. Built with FuzzyScan. Imaging Technology, durable ultra-compact design and rich functionality, it provides an ideal barcode scanning solution for both industrial and general purpose applications. This document provides a quick reference for installation and operation. The complete documentation is available at FM48 Series (Front-view Model) FA47 Series (Front-view Model) FM48 Series (Side-view Model) Power Indicator Status Indicator OK/NG Indicator Intelli Button Scan Window M Mounting Hole FA47 Series (Side-view Model)

8 Connect to Your Host Both RS and USB interfaces are available in different models. Each model is equipped with corresponding connector to meet various application demands. USB Models (FM4xx-x) The USB models provide a plug-and-play solution. Both USB HID and USB COM Port Emulation interfaces are available for user s choice. Pin No. Signal Description I/O Type Case FG Frame Ground --- VCC --- I Data - USB Data - I/O Data + USB Data + I/O 4-pin Type A Connector 4 GND RS Models (FM4xx-x) The RS models support the standard RS interface equipped a 9-pin D-sub connector with power jack for external 5Vdc power inlet. Pin No. Signal Description I/O Type Case FG Frame Ground TXD Transmit Data I RXD Receive Data O pin D-sub 5 GND Signal Ground --- Female Connector CTS Clear to Send I 8 RTS Request to Send O 9 VCC 5Vdc Power Supply I Universal Models (FM4xx-98x) The universal models support RS and USB interfaces with OK/NG signal outputs and external trigger input. 5-pin D-sub HD Female Connector Pin No. Signal Description I/O Type VCC 5Vdc Power Supply I TXD Transmit Data O RXD Receive Data I 4 GND Signal Ground RTS Request to Send O 7 OK OK Signal Output (-4Vdc) 8 Data + USB Data + I/O 9 Trigger External Trigger Input I CTS Clear to Send I Data - USB Data - I/O Shield Frame Ground NG NG Signal Output (-4Vdc) 5 Reserved O O

9 Install Your FuzzyScan Adjust Reading Angle The readability may be impacted by the specular reflection caused by the perpendicular reading angle. To get the most optimal reading performance, you are suggested to install the scanner at an approximate 5 angle to the perpendicular line of the target barcode. However, the reading angle and distance may vary depending on the size and printing quality of barcodes. Mount Your FuzzyScan Front-view Side-view There are two M mounting holes on the bottom of the chassis. Please follow below procedures to mount your scanner. Prepare two appropriate M screws (minimal 4mm in depth) and decide your desired mounting location. Then adjust the two screws to accommodate 7mm center width. Optimize the mounting position by adjusting the reading angle and distance. Ensure the illumination envelop is not blocked by any external object. Use the Intelli Button to verify the actual reading rate. If the reading rate is not good enough, please adjust the reading angle and distance to get the optimum readability.

10 Intelli Button For normal operation, the Intelli Button of the scanner acts as a manual Trigger Switch. You can press the Intelli Button to scan the corresponding barcode commands to configure your scanner with ease. Moreover, the useful Intelli Button can help you to identify the best mounting position. Please refer to following descriptions for more details. Optimize Your Installation Once the mounting position for the scanner is determined, you may use the Intelli Button to optimize the mounting position with ease. Please follow below procedures to use the Intelli Button. Press and hold the Intelli Button for more than 5 seconds until the status indicator gives one green blink, then release the button. The scanner will emit short beeps and the power indicator will flash blue blink per second to indicate the force reading process is activated. The scanner will turn on the light source to scan barcodes continuously until the whole process completed. Keep the scanner to read the same barcode. The scanner will count the Good Read numbers, then output the information of reading rate and refresh LED indications every scans. The format of output message is listed below. < Readout data > : < Reading rate ( to ) > Meanwhile, both Status and OK/NG indicators provide the visible reading rate information as well. You may refer to the table listed below for details. Reading rate STATUS Indicator OK/NG Indicator % Steady Green Steady Green 8 to 99% Steady Red Steady Green 5 to 79% Steady Green Steady Red to 49% Steady Orange Steady Orange to 9% Steady Red Steady Red If the reading rate is not good enough, please adjust the reading angle and distance to get the optimum readability. If you would like to exit the force reading process, please press the Intelli Button once again.. If the scanner is unable to read any barcode during preset scan input time-out (default is 9ms), the scanner will count it as a NG reading. During force reading process, the OK/NG output signals will not be Performed. 4

11 Use Your FuzzyScan Both FuzzyScan Barcode commands and Serial commands are available to configure your scanner. The FuzzyScan barcode commands are a series of proprietary barcodes which allow you to easily configure the scanner for most applications. Moreover, the FuzzyScan serial commands are ideal for precise and complicated reading control in machine-controllable environments. Please refer to the relevant documentations for details. External Trigger and Serial Trigger The scanner provides both external trigger and serial trigger to activate the scanning processes. Please note that the external trigger is only available for universal models. The serial trigger is workable for all models including RS serial and USB COM Port Emulation interfaces. User Defined Serial Trigger Command For user s convenience to replace the other existing fixed mount scanner, the useful user defined serial trigger command allows you to trigger the scanner without impacting the existing application programs. Scan Input Time-out The scan input time-out is an adjustable value for the time period that light source turns on. It s available for presentation, alternative and level modes. The scanner keeps the light source on and continues to scan until the defined scan input time-out is up. You can adjust the time-out duration from milliseconds to 99 seconds to meet various demands. OK and NG Outputs The universal models support additional OK and NG outputs for more precise reading control. If the scanner got a good read, a signal will be outputted through the OK pin. However, if the scanner failed to read the barcode during a reading cycle or preset scan input time-out, a signal will be outputted through the NG pin. The OK and NG outputs are designed as NPN signal outputs and preset to active low. You may change the active state of OK and NG outputs to meet your applications Operation Modes The FuzzyScan Fixed Mount Scanner provides five different operation modes, including trigger, alternative, level, presentation and force modes to meet various application demands Both the presentation and force modes support triggerless operation, you don t need to use either external trigger or serial trigger to activate the scanning. But the trigger, alternative and level modes have to work with external trigger or serial trigger to scan barcode 5

12 Operation Mode area-imaging fixed mount scanner The details of each operation mode supported by FA47 area-imaging fixed mount scanner are listed below. Trigger Mode Under trigger mode, the scanner will turn on the light source to read barcode when it receives an external trigger or a serial trigger ON command. Once the external trigger has been released, or the scanner gets a good read or a serial trigger OFF command, the scanner will stop reading and wait for the next trigger to activate scanning again. Alternative Mode When the scanner receives an external trigger or a serial trigger ON command under alternative mode, the scanner will turn on the light source to read barcodes until the preset scan input time-out is up. The scan input time-out will be reset after each good read. Once the light source goes off, the scanner is waiting for the next trigger to activate scanning again. Level Mode When the scanner receives an external trigger or a serial trigger ON command under level mode, the scanner will turn on the light source to read barcodes until a good read is performed or the preset scan input time-out is up. Once the light source goes off, the scanner is waiting for the next trigger to activate scanning again. Presentation Mode When presentation mode is selected, the scanner is preset to turn on the background lighting to detect the bar codes. Once the scanner detects an image similar to a bar code in the scanner field of view, it will turn on the light source to scan until the preset scan input time-out is up. You may adjust the setting of Presentation Sensitivity to increase detection sensitivity. Force Mode Under Force Mode, the scanner continues to read barcodes without using external trigger or serial trigger. Please note that the scanner will not stop reading until you switch to another operation mode. 6

13 Operation Mode linear fixed mount scanner The details of each operation mode supported by FM48 fixed mount scanner are listed below. Trigger Mode Under trigger mode, the scanner will turn on the light source to read barcode when it receives an external trigger or a serial trigger ON command. Once the external trigger has been released, or the scanner gets a good read or a serial trigger OFF command, the scanner will stop reading and wait for the next trigger to activate scanning again. Alternative Mode When the scanner receives an external trigger or a serial trigger ON command under alternative mode, the scanner will turn on the light source to read barcodes until the preset scan input time-out is up. The scan input time-out will be reset after each good read. Once the light source goes off, the scanner is waiting for the next trigger to activate scanning again. Level Mode When the scanner receives an external trigger or a serial trigger ON command under level mode, the scanner will turn on the light source to read barcodes until a good read is performed or the preset scan input time-out is up. Once the light source goes off, the scanner is waiting for the next trigger to activate scanning again. Presentation Mode Under presentation mode, the scanner will automatically detect the object movement in the scanner field of view. Once the scanner detects an image similar to a barcode, it will turn on the light source to scan until the preset scan input time-out is up. For dark environments, you may adjust the setting of Presentation Sensitivity to increase the detection sensitivity. Force Mode Under force mode, the scanner continues to read barcodes without using external trigger or serial trigger. Please note that the scanner will not stop reading until you switch to another operation mode. 7

14 Bar Code Programming Menu The FuzzyScan bar code commands are specially designed Proprietary bar code labels which allow you to set the FuzzyScan internal programming parameters. There are System Command, Family Code and Option Code for programming purpose. Each programmable family and bar code command label is listed on the same page with major system commands. The detailed explanations and special programming flowchart are printed on facing or following pages. You can read the explanation and set the FuzzyScan concurrently. A supplemental bar code command menu incorporates the bar code command labels of System Command and Option Code. As you set the FuzzyScan, open the bar code command menu to find the option code page. You may scan the desired family code and option code to set FuzzyScan. If you want to change the programming family for multiple settings, you need only turn over the programming page to find next desired programming family. operations. User must wait for the completion beeps before scanning another bar code. Family Code The Family Code is scanned to select the user desired programming family. FuzzyScan has already provided more than one hundred programming families to meet any specific requirements. Option Code The Option Codes is a set of bar code commands represented by 9, A F and finishing selection (). For most setting, you must select at least one option code following the family code selection to set the desired parameter for the selected programming family. System Command The System Command is the highest level bar code command which directs FuzzyScan to perform immediate operations, such as entering programming mode (), exiting programming mode (EXIT), listing system information (SYSLIST), recovering to factory preset configurations (M_DEFAULT), and so on. Please note that all system commands will take a few seconds to complete the 8

15 Programming Procedures As you scan the bar code command to select the desired parameters, information about the final selected parameters represented by the bar code commands are stored in the FuzzyScan s internal Flash Memory ASIC or non-volatile memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programming options. You need not re-program the FuzzyScan if you want to keep the existing configurations in the next power on. The programming procedures of FuzzyScan are designed as simple as possible for ease of setting. Most programming families take the Single Scan Selection programming procedure. But several programming families have more complex and flexible programmable options, and you must take Multiple Scans Selection, Cycling Scan Selection or Dual Level Selection to complete their programming procedures. Each kind of programming procedure is listed in the following pages for your reference. Please give careful attention to become familiar with each programming procedure. If the programming family must take multiple scans selection, cycling scan selection, or dual level selection procedures, the family of the programming menu will be marked with the matched representing symbol of Programming Category (P.C.) in bold font listed in the following table. You can easily find the bold mark in the programming menu, and refer to their flowcharts for details. Before setting the FuzzyScan, please also refer to the Beeping Indications listed in Appendix to understand the details of programming beeping indications. It will be very helpful for you to know the existing status while you are programming the FuzzyScan. Conventions of Programming Menu Conventions Descriptions Factory Default Value P.C. Programming Category : Signle scan selection : Multiple scans selection CS : Cycling scan selection DS : Dual level scan selection ( ) Necessary Option Code [ ] Selectable Option Code 9

16 Program & End System List, Group & Master Default Scan Scan SYSLIST FuzzyScan will enter programming mode, and inhibit all non-programming functions. FuzzyScan will list the product information and revision number to host via selected host interface, then issue the completion beeping. Scan END Scan M_DEFAULT FuzzyScan will exit programming mode, and store all parameters in Flash Memory ASIC or non-volatile memory, then issue the completion beeping. FuzzyScan will recover all programmable parameters into factory preset configurations, then issue the completion beeping. Please note that the FuzzyScan will take -4 seconds to store parameters in internal Flash Memory ASIC or non-volatile memory after you scan the END. Please don t turn off the power before the completion beeping. It may destroy all configured parameters.

17 Single scan selection Multiple scans selection Scan Enter programming mode. Scan Enter programming mode. Scan One of Family Codes Select one of desired programming families. Scan One of Family Codes Select one of desired programming families. Scan One of Option Codes Select one option code of desired parameter. Scan One or Several Option Codes. Select one or several option codes to select desired parameters.. If it s necessary, scan Yes Repeat Selection Want to select another programming family? Yes Repeat Selection to terminate option code selection. Want to select another No No programming family? Scan END Exit programming mode. Scan END Exit programming mode.

18 Dual level selection Cycling scan selection S ca n S ca n P R O G R A M E nter program m ing m ode. P R O G R A M E nter program m ing m ode. S ca n O n e o f F a m ily C o d e s S elect one of desired program m ing fam ilies. S ca n O n e o f F a m ily C o d e s S elect one of desired program m ing fam ilies. S ca n O n e o f O p tio n C o d e s S ca n F IN C yclin g select o n e o r several o p tio n co d es o f d esired p aram eters as S in g le o r M u ltip le scan s selectio n. (st) S ca n S e ve ra l O p tio n C o d e s ( n d ) S ca n O n e o r S e ve ra l O p tio n C o d e s S elect several o p tio n co d es o f d esired p aram eters.. S elect o n e o r several o p tio n co d es o f d esired p aram eters.. If it s n ecessary, scan F IN to term in ate F in ish cyclin g selectio n. o p tio n co d e selectio n. Ye s R e p e a t S e le ctio n No S ca n E N D (If necessary) W ant to select another program m ing fam ily? E x it program m ing m ode. Ye s R e p e a t S e le ctio n No S ca n E N D W ant to select another program m ing fam ily? E x it program m ing m ode.

19 Host Interface Selection Host Interface Selection Standard/TTL RS- peer-to-peer serial USB Com Port Emulation USB HID standard mode USB HID turbo mode USB HID Legacy

20 Symbology Reading Control User Defined Symbol ID nd Option Code Symbol ID : character DS Code 8 (default=b) GS-8 (default=c) UPC-A (default=a) EAN- (default=f) Codabar/NW-7 (default=d) Code 9/Code (default=g) Code 9 (default=h) Standard/Industrial of 5 (default=i) Interleaved of 5 (default=j) Matrix of 5 (default=k) China Postal Code (default=l) German Postal Code (default=m) IATA (default=o) Code (default=p) I/Plessey (default=r) UK/Plessey (default=s) Telepen (default=t) GS DataBar (default=x) UPC-E (default=e) EAN-8 (default=n) Trioptic Code 9 (Default=W) UCC Coupon Extended Code (Default=Z) PDF47/Micro PDF47 (default=v) Codablock F (default=y) Code 6K (default=q) Code 49 (default=u) Korea Post Code (default=a) QR & Micro QR Code (default=b) Data Matrix (default=c) Maxi Code (default=d) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) 4

21 Symbology Reading Control User Defined Symbol ID nd Option Code Symbol ID : character DS Aztec Code (default=e) Chinese Sensible (default=f) Australian Post (default=g) British Post (default=h) Intelligent Mail (USPS 4CB/One Code) (default=j) Japan Post (default=k) Netherlands KIX Post (default=l) US Planet (default=m) US Postnet (default=o) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) 5

22 Symbology Reading Control Symbology ID Transmission Symbology ID Transmission Disable symbology ID transmission Enable prefix CINO symbology ID transmission Enable suffix CINO symbology ID transmission Enable both prefix and suffix CINO symbology ID transmission Enable prefix AIM symbology ID transmission Enable suffix AIM symbology ID transmission Enable both prefix and suffix AIM symbology ID transmission

23 Symbology Reading Control Readable Bar Code Setting Readable Symbology Setting Auto CS Code 8 * Remember to scan to terminate this selection. But if you select the CS CS CS CS CS CS CS CS CS CS CS CS CS CS GS-8 * UPC-A * UPC-E * EAN- * EAN-8 * Codabar/NW-7 * Code 9 * Trioptic Code 9 Standard/Industrial of 5 Matrix of 5 Interleaved of 5 * China Postal Code Germany Postal Code Code 9 * Auto, FuzzyScan will terminate this CS Code CS I/Plessey selection automatically. CS CS CS CS CS CS CS CS CS CS CS CS CS CS UK/Plessey Telepen GS DataBar (R-4) * IATA PDF47 * /Micro PDF47 Codablock F Code 6K Code 49 Korea Post Code QR Code */ Micro QR Code * Data Matrix * MaxiCode Aztec Code * Chinese Sensible (Han Xin) Code A A A A A4 7

24 Symbology Reading Control Readable Bar Code Setting Readable Symbology Setting CS Australian Post B CS British Post B CS CS CS CS CS Intelligent Mail barcode Japanese Post KIX Post Planet Code Postnet B B4 B5 B6 B8 If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add the Symbology ID into the transmitted data is also helpful to identify the specific symbology. Above symbologies marketed with * are enabled as default. When you select Auto, the scanner only reads those symbologies marked with *. When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn t include start/stop characters. 8

25 Symbology Reading Control Code 9/Code Setting Code 9 Family Setting Trioptic Code 9 Setting Disable Code 9 Enable Code 9 Select Standard Code 9 as primary format Select Full ASCII Code 9 as primary format Select Code (PARAF, Italian Pharmaceutical) as primary format Disable start/stop symbol transmission Enable start/stop symbol transmission Disable Code leading A transmission Enable Code leading A transmission Disable MOD 4 check digit verification Enable MOD 4 check digit verification Disable check digit transmission Enable check digit transmission Disable Code 9 buffering Enable Code 9 buffering Disable Trioptic Code 9 Enable Trioptic Code A B C D E Code 9 Min. Length Default () -Maximum ( digits) Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 9 Max. Length Default (98) 98-Minimum Trioptic Code 9 and Code 9 Full ASCII cannot be enabled simultaneously. Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) 9

26 Symbology Reading Control Code 9 Setting Code 9 Security Level Level Level Level Level Code 9 Security Level The scanner offers four levels of decode security for Code9 bar codes: Level : If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level, please select level. Level : If you are experiencing misread of poorly-printed or out-of-spec. bar codes in level, please select level. Level : This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding in-spec Code9 bar codes. Level : If you failed to read poorly-printed or out-of-spec. bar codes in level, please select level. This is the most aggressive setting and may increase the misread.

27 Symbology Reading Control Codabar/NW-7 Setting Codabar Setting Disable Codabar Enable Codabar Select Codabar standard format Select Codabar ABC format Select Codabar CLSI format Select Codabar CX format Disable start/stop symbol transmission Enable ABCD/ABCD start/stop symbol transmission Enable abcd/abcd start/stop symbol transmission Enable ABCD/TN*E start/stop symbol transmission Enable abcd/tn*e start/stop symbol transmission Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission A B C D E Codabar Check Digit Settings Modulus 6 Modulus /weight Modulus Modulus /weight 7 check DR Weight Modulus Runes (Modulus /weight ) Codabar Min. Length Default (4) -Maximum ( digits) Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.

28 Symbology Reading Control Codabar/NW-7 Setting Codabar Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits)

29 Symbology Reading Control UPC-A & UPC-E Setting UPC Family Setting Disable UPC-A Enable UPC-A Disable UPC-E Enable UPC-E Disable UPC-E expansion Enable UPC-E expansion Disable UPC standardization Enable UPC standardization Disable UPC numeric system Enable UPC numeric system Disable UPC-A check digit transmission Enable UPC-A check digit transmission Disable UPC-E check digit transmission Enable UPC-E check digit transmission Disable UPC leading portion Enable UPC leading portion When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric system, UPC-A check digit transmission. UPC-E & EAN-8 Expansion : Expand the 8-digit UPC-E and 8-digit ENA-8 to -digit UPC-A and -digit EAN-. UPC-A Standardization : Expand the -digit UPC-A to -digit EAN- with zero insertion. UPC Lead Numeric System : Enable to read UPC leading with the numeric system, you must enable this option A B C D E F WPC Selection (UPC/EAN/CAN) Basic Length Disable Check Digit Disable Numeric System With -digit Addendum With 5-digit Addendum Enable Standardization Enable Expansion UPC-A UPC-E EAN- - NC NC EAN NC NC + 5

30 Symbology Reading Control UPC-A & UPC-E Setting, Supplement Scan Voting UPC Supplement Setting Select UPC without supplement digits Select UPC with only supplement digits Select UPC with only 5 supplement digits Select UPC with /5 supplement digits Disable force supplement digits output Enable force supplement digits output UPC Family Addenda Separator Off UPC Family Addenda Separator On UPC/EAN Security Level Level Level Level Only available for UPC-A & EAN- Supplement Scan Voting None Level Level Level Level 4 Level 5 Level 6 Level 7 Level 8 Level 9 Level Level Level Level UPC/EAN Security Level The scanner offers three levels of decode security for UPC/EAN bar codes: Level : If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters,, 7, and 8 in level, please select level. Selection of this security level may significantly impair the decoding ability of the scanner. Level : This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding in-spec UPC/EAN bar codes. Level : If you are experiencing misread of poorly-printed, soiled or damage bar codes in level, please select level. This is the most aggressive setting and may increase the misread. The Supplement Scan Voting is the number of times the same UPC/EAN with /5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with /5 supplement digits. The default value is Level. When you select higher level, it may impact the reading speed on poorly-printed, low contrast or damage barcode labels A B C D 4

31 Symbology Reading Control EAN Setting, Supplement, Supplement Scan Voting EAN Setting EAN Supplement Setting Disable EAN- Enable EAN- Disable EAN-8 Enable EAN-8 Disable EAN-8 expansion Enable EAN-8 expansion Disable EAN- check digit transmission Enable EAN- check digit transmission Disable EAN-8 check digit transmission Enable EAN-8 check digit transmission Disable ISBN/IN Conversion reading check Enable ISBN/IN Conversion reading check Select EAN without supplement digits Select EAN with only supplement digits Select EAN with only 5 supplement digits Select EAN with /5 supplement digits Disable force supplement digits output Enable force supplement digits output EAN Addenda Separator Off EAN Addenda Separator On A B Supplement Scan Voting None Level Level Level Level 4 Level 5 Level 6 5 Level 7 Level 8 Level 9 Level Level Level Level The Supplement Scan Voting is the number of times the same UPC/EAN with /5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with /5 supplement digits. The default value is Level. When you select higher level, it may impact the reading speed on poorly-printed, low contrast or damage barcode labels A B C D

32 Symbology Reading Control UPC/EAN Security Level Setting, EAN Supplement Control UPC/EAN Security Level Level Level Level Only available for UPC-A & EAN- EAN Supplement Control Disable all specific prefix supplement digital output Enable all specific prefix supplement digital output Enable 49 Supplement Digit Output Enable 978/979 Supplement Digit Output Enable 977 Supplement Digit Output Enable 78/79 Supplement Digit Output Enable 44/49 Supplement Digit Output Enable 44/49 Supplement Digit Output UPC/EAN Security Level The scanner offers three levels of decode security for UPC/EAN bar codes: Level : If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters,, 7, and 8 in level, please select level. Selection of this security level may significantly impair the decoding ability of the scanner. Level : This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding in-spec UPC/EAN bar codes. Level : If you are experiencing misread of poorly-printed, soiled or damage bar codes in level, please select level. This is the most aggressive setting and may increase the misread. EAN Supplement Control If you select EAN with only, or 5 or /5 supplement digits and enable 49 prefix supplement digit output, the scanner will transmit EAN with, or 5 or /5 supplement digits bar codes starting with 49 prefix. The EAN without supplement digit will not be transmitted. If you select EAN with only, or 5 or /5 supplement digits and enable the other except 49 prefix supplement digit output, the scanner will transmit EAN with, or 5, or /5 supplement digits bar codes starting with specific prefix. The EAN without supplement digit will be transmitted. 6

33 Symbology Reading Control UCC Coupon Extended Code Setting UCC Coupon Extended Code Disable UCC Coupon Extended Code Enable UCC Coupon Extended Code UCC Coupon Extended Code When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit 5, EAN- barcodes starting with digit 99 and GS-8 Coupon Codes. UPC-A, EAN- and EAN-8 must be enabled to scan all types of Coupon Codes. 7

34 Symbology Reading Control IATA & Interleaved of 5 Setting IATA Setting Disable IATA Enable IATA Select 5-digit fixed length IATA checking Select variable length IATA Disable check digit verification Enable check digit automatic verification Enable S/N checking digit verification only Enable CPN checking digit verification only Enable CPN, Airline and S/N check digit verification Disable check digit transmission Enable check digit transmission Disable start/stop symbol transmission Enable start/stop symbol transmission A B C Interleaved of 5 Setting Disable Interleaved of 5 Enable Interleaved of 5 Select Interleaved of 5 as primary format Select German Postal Code as primary format No check character Validate U check digit Validate OPCC check digit Disable check digit transmission Enable check digit transmission

35 Symbology Reading Control Code 5 Family Setting Code 5 Setting Code 5 Family Min. Length Disable Standard/Industrial of 5 Enable Standard/Industrial of 5 Disable Matrix of 5 Enable Matrix of 5 Disable China Postal Code Enable China Postal Code Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission Default (4) -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically ( digits) Code 5 Family Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) For Code5 setting, we recommend you to select only one type of Code 5 or set the maximum/minimum bar code length. To decode all types of Code 5 or to variable length of Code 5 will increase the possibility of reading error. 9

36 Symbology Reading Control Code & Code 9 Setting Code Setting Disable Code Enable Code Disable check digit verification Select -check digit verification Select -check digit verification Disable check digit transmission Enable check digit transmission Code Min. Length Default (4) -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) Code Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) Code 9 Setting Disable Code 9 Enable Code 9 Disable check digit transmission Enable check digit transmission Code 9 Min. Length Default () -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) Code 9 Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits)

37 Symbology Reading Control I/Plessey Setting I/Plessey Setting Disable I/Plessy Enable I/Plessy Select MOD check digit Select MOD - check digit Select MOD - check digit Disable check digit transmission Enable check digit transmission I/Plessey Min. Length Default (4) -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) I/Plessey Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits)

38 Symbology Reading Control Code 8 Setting Code 8 Setting Disable Code 8 Enable Code 8 ISBT Concatenation Off ISBT Concatenation On Code 8 Min. Length Default () -Maximum ( digits) Scan digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Code 8 Max. Length Default (98) 98-Minimum ( digits) Scan digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Code 8 Security Level Level Level Code 8 Security Level The scanner offers two levels of decode security for Code8 bar codes: Level : If you are experiencing misread of poor-printed or out-of-spec. bar code in level, please select level. Level : This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding "in-spec." Code8 bar codes.

39 Symbology Reading Control GS-8 Setting GS-8 Setting Disable GS-8 Enable GS-8 GS-8 Min. Length Default () -Maximum ( digits) Scan digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. GS-8 Max. Length Default (98) 98-Minimum ( digits) Scan digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically.

40 Symbology Reading Control UK/Plessey Setting UK/Plessey Setting Disable UK/Plessey Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission UK/Plessey Min. Length Default (4) -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) UK/Plessey Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) 4

41 Symbology Reading Control Telepen Setting Telepen Setting Telepen Min. Length Disable Telepen Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission Default (4) -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 4 5 ( digits) Telepen Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) 5

42 Symbology Reading Control GS DataBar Setting GS DataBar Setting Disable GS DataBar (R-4) Enable GS DataBar (R-4) Disable GS DataBar Limited Enable GS DataBar Limited Disable GS DataBar Expanded Enable GS DataBar Expanded 4 5 GS DataBar Min. Length Default (4) -Maximum ( digits) Only available for GS Databar Expanded. Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. GS DataBar Max. Length Default (74) 74-Minimum ( digits) Only available for GS Databar Expanded. Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 6

43 Symbology Reading Control Composite Codes, PDF47/microPDF47, Codablock F Setting Composite Codes Setting Disable composite codes Enable composite codes UPC Composite Mode: UPC never linked UPC Composite Mode: UPC always linked If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted whether MicroPDF47 symbol is detected or not. If UPC Composite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF47 is detected. PDF47/MicroPDF47 Setting Disable PDF47 Enable PDF47 Disable MicroPDF47 Enable MicroPDF47 Codablock F Setting Disable Enable 7

44 Symbology Reading Control Code 6K & Code 49 Setting Code 6K Setting Disable Code 6K Enable Code 6K Code 6K Min. Length Default () -Maximum ( digits) Scan digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Code 6K Max. Length Default (6) 6-Minimum ( digits) Scan digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Code 49 Setting Disable Code 49 Enable Code 49 Code 49 Min. Length Default () -Maximum ( digits) Scan digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Code 49 Max. Length Default (8) 8-Minimum ( digits) Scan digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. 8

45 Symbology Reading Control QR Code Setting QR Code Setting QR Code Min. Length Disable QR Code Enable QR Code Disable MicroQR Code Enable MicroQR Code Disable QR Code Append Enable QR Code Append Disable QR Code Inverse Reading Enable QR Code Inverse Reading Auto detect QR Code Inverse Reading Default () -Maximum (4 digits) Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. QR Code Max. Length Default (789) 789-Minimum Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. (4 digits) 9

46 Symbology Reading Control Data Matrix Setting Data Matrix Setting Disable Data Matrix Enable Data Matrix Disable Data Matrix Inverse Reading Enable Data Matrix Inverse Reading Auto Detect Data Matrix Inverse Reading Disable Data Matrix Mirror Images Enable Data Matrix Mirror Images Auto Detect Data Matrix Mirror Images Data Matrix Min. Length Default () -Maximum Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. (4 digits) Data Matrix Max. Length Default (6) 6-Minimum (4 digits) Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Small DM Code Reading Standard Level Level Small DM Code Reading: When small DataMatrix code can t be read by D scanner, you can select "Level or Level to improve the scanner's ability to read small DataMatrix code. The scanner s snappiness decreased when you select Level or Level. The higher level will take longer time to read the small DataMatrix barcode. Small DM Code Reading: Available firmware: FA77.. and above;..8 and above. 4

47 Symbology Reading Control MaxiCode Setting MaxiCode Setting Disable MaxiCode Enable MaxiCode MaxiCode Min. Length Default () -Maximum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) MaxiCode Max. Length Default (5) 5-Minimum Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) 4

48 Symbology Reading Control Aztec Code Setting Aztec Code Setting Disable Aztec Code Enable Aztec Code Aztec Code Min. Length Default () -Maximum (4 digits) Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Aztec Code Max. Length Default (8) 8-Minimum (4 digits) Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. 4

49 Symbology Reading Control Australian Post, US Planet, US Postnet, British Post & Japan Post Setting Australian Post Setting Disable Australian Post Enable Australian Post Raw format Output Numeric Encoding Output (N Encoding Table) Alphanumeric Encoding Output (C Encoding Table) Auto-discriminate Output (Combination C & N Encoding Table) 4 5 US Planet Setting Disable US Planet Enable US Planet Disable Check Digit Transmission Enable Check Digit Transmission US Postnet Setting Disable US Postnet Enable US Postnet Disable Check Digit Transmission Enable Check Digit Transmission British Post Setting Disable British Post Enable British Post Disable Check Digit Transmission Enable Check Digit Transmission Japan Post Setting Disable Japan Post Enable Japan Post Australian Post Setting: Auto-discriminate output option increase the risk of misread because the encoded data format does not specify the Encoding Table used for encoding. 4

50 Symbology Reading Control Netherlands KIX Code, Intelligent Mail & Korea Post Code Setting Netherlands KIX Code Setting Disable Netherlands KIX Code Enable Netherlands KIX Code Intelligent Mail Setting (USPS 4CB/One Code) Disable Intelligent Mail Enable Intelligent Mail Korea Post Code Setting Disable Enable Length fixed in 6 characters. 44

51 Keyboard Interface Control Keyboard Layout (Language) Setting Keyboard Layout USA (QWERTY) France (AZERTY) Germany (QWERTZ) United Kingdom - UK (QWERTY) Canadian French (QWERTY) Spain (Spanish, QWERTY) Sweden/Finland (QWERTY) Portugal (QWERTY) Norway (QWERTY) Spain (Latin America, QWERTY) Italy (QWERTY) Netherlands (QWERTY) Denmark (QWERTY) Belgium (AZERTY) Switzerland-Germany (QWERTY) Iceland (QWERTY) Japan (DOS/V) Czech (QWERTY) Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as preamble or postamble. To set preamble or postamble as function key output, you must enable the Function Key Emulation feature as listed in page -5 first. Keyboard Interface Message String : Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble Record Suffix -5 characters -4 digits or characters Variable length or characters -5 characters character

52 Keyboard Interface Control Record Suffix, Preamble, Postamble FNC Transmit & Caps Lock Record Suffix None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character ( character) 4 5, (-7F) Preamble None -5 characters [-7F], [] Maximum 5-character input; scan to terminate this selection. Postamble None -5 characters [-7F], [] Maximum 5-character input; scan to terminate this selection. FNC Symbol Char. Transmit Disable Enable Caps Lock Control Caps Lock Off State Caps Lock On State Auto Detect (PC/AT, PS/, Keyboard Replacement and DOS/V Machines only) Caps Lock Release Control Caps Lock On, Caps Off Caps Lock On, Shift Off 46

53 FNC Symbol Char. Transmit: When this function is enabled and the FNC is contained in scanned data, the scanner transmits the FNC to the host. Chart of thefnc is provided in Appendix- Keyboard Function Code Table. When the scanner interface is set to keyboard, the scan code is converted to corresponding key function before it is transmitted. The function of Caps Lock Control and Key Pad Emulation are only available for IBM PC/AT, PS/VP, PS/ series personal computers and compatible machines. While selecting the other host interfaces, these selections don t perform the above functions for you. Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select Caps Lock Off state, then FuzzyScan will perform normal data transmission. If the Caps Lock state is on, select Caps Lock On state. Select Auto Detect, FuzzyScan will perform special transmission handshaking without changing the status of Caps Lock switch. 47

54 Keyboard Interface Control Delay Setting Intermessage Delay None -99 (x5) msec. Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) Intercharacter Delay None -99 (x5) msec. ( digits) Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Interfunction Delay None -99 (x5) msec. ( digits) Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time. Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : ) the data transmission speed is too fast, characters may be skipped; ) multitasking operation system or host computers in a network may slow down the keyboard handling; ) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters. Interfunction Delay is a time delay between the transmission of each segment of the message string. 48

55 Keyboard Interface Control Emulation Setting & Upper/Lower Case Setting Dollar Sign control Function Key Emulation Enable ASCII - code as keyboard function code output Ctrl-Output Refer to Appendix Keyboard Function Code Table for details. Key Pad Emulation Disable key pad emulation Enable numeric output as key pad (Num Lock On) output Upper/Lower Case Normal case (neglect the upper/lower case control) Inverse case (change all characters output to inverse case) Upper case (force all characters output as upper case) Lower case (force all characters output as lower case) Dollar Sign Control Dollar sign output as $ Dollar sign output as Dollar sign output as Dollar sign output as Dollar sign output as 4 49

56 Serial Interface Control Record Suffix, Preamble, Postamble Setting STX/ETX Control Disable STX/ETX transmission Enable STX/ETX transmission STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface. Record Suffix None CR (DH) LF (AH) CRLF (DAH) TAB (9H) SPACE (H) User defined character ( character) 4 5 6, (-7F) Preamble None -5 characters [-7F], [] Maximum 5-character input; scan to terminate this selection. Postamble None -5 characters [-7F], [] Maximum 5-character input; scan to terminate this selection. FNC Symbol Char. Transmit Disable Enable Serial Interface Message String (RS, USB COM) : When this function is enabled and the FNC is contained in scanned data, the scanner transmits the FNC to the host. Chart of the FNC is provided in Appendix Keyboard Function Code Table. When the scanner interface is set to keyboard, the scan code is converted to corresponding key function before it is transmitted STX Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble ETX Record Suffix character -5 characters -4 digits or characters Variable length or characters -5 characters character character 5

57 Serial Interface Control Delay Setting Intermessage Delay None -99 (x5) msec. Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. ( digits) Intercharacter Delay None -99 (x5) msec. ( digits) Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Interfunction Delay None -99 (x5) msec. ( digits) Scan digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time. Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : ) the data transmission speed is too fast, characters may be skipped; ) multitasking operation system or host computers in a network may slow down the keyboard handling; ) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters. Interfunction Delay is a time delay between the transmission of each segment of the message string. 5

58 Serial Interface Control Protocol, ACK/NAK Setting Handshaking Protocol None (free running mode) RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking) NAK Retry Count times ~55 times ( digits) ACK Indication Disable ACK Time-out Indication Enable ACK Time-out Indication Disable ACK Indication Enable ACK Indication USB COM doesn t support RTS/CTS handshaking protocol. When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK. NAK Retry Count After transmitting data, the scanner expects a NAK response from the host up to the preset Serial Response Time-out. If the scanner doesn t get a response, the scanner will issue an error indication and discard the data. When a NAK is received, the scanner transmits the same data again and waits for either an ACK or NAK. The scanner issues an error indication and discards the data under following two conditions: ) After preset NAK retry counts is received within the preset serial response time-out. ) If the preset time-out is up but the preset NAK retry counts haven t come to the end. The default retry counts are three times. If you program time, the scanner won t resend the data to the host when the scanner receives a NAK. The scanner will discard the data. If you program 55 times, the scanner can receive unlimited NAKs from the host within the pre-set serial response time-out. This function is not available for batch mode. When you enable this function in on-line mode, the out-of-range function will be disable automatically. ACK Indication: Disable: There s neither LED nor beeping indication for this setting. Enable: There s a specific LED and beeping indication for this setting. 5

59 Serial Interface Control Time Out Setting, Baud Rate, Data Frame Serial Response Time-out None mseconds 5 mseconds 8 mseconds second seconds seconds 4 seconds 5 seconds 8 seconds seconds 5 seconds A B Baud Rate (BPS) 8.4K BPS 9.K BPS 96 BPS 48 BPS 4 BPS BPS 57.6K BPS 5.K BPS Data Frame 8, None, 8, Odd, 8, Even, 8, Space, 8, Mark, 8, None, 7, Odd, 7, Even, 7, Space, 7, Mark, 7, None, 7, Odd, 7, Even, 7, Space, 7, Mark, When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data communication. This option is very helpful to ensure the reliability of data communication. The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer A B C D E 5

60 Operation Control FM48 Operation Mode Setting Operation Mode Trigger mode Presentation mode Alternative mode Force mode Level mode Trigger Mode (External Triggering) When the scanner receives an external trigger or a serial trigger ON command under trigger mode, the scanner will turn on the light source to read barcode until gets a good read, a serial trigger OFF command or a release of external trigger. Once the light source goes off, the scanner is waiting for the next trigger to activate scanning again. Presentation Mode (Auto Detection) Under presentation mode, the scanner will automatically detect the object movement in the scanner field of view. Once the scanner detected a similar barcode image, the scanner will turn on the light source to read barcodes until the preset scan input time-out is up. For dark environments, you may adjust the setting of Presentation Sensitivity to increase the detection sensitivity Alternative Mode (Periodic Power Off) When the scanner receives an external trigger or a serial trigger ON command under alternative mode, the scanner will turn on the light source to read barcodes until the preset scan input time-out is up. The scan input time-out will be reset after each good read. Once the light source goes off, the scanner is waiting for the next trigger to activate scanning again. Force Mode (Continued Power On) Under force mode, the scanner continues to read barcodes without using external trigger or serial trigger. Please note that the scanner will not stop reading until you switch into another operation mode. Level Mode (Auto Power Off) When the scanner receives an external trigger or a serial trigger ON command under level mode, the scanner will turn on the light source to read barcodes until a good read is performed or the preset scan input time-out is up. Once the light source goes off, the scanner is waiting for the next trigger to activate scanning again

61 Operation Control FM48 D Barcode Reading Direction, D Barcode Direction Indication Transmission, Scan Rate Control D Barcode Forward-reading Indication None S User defined character( character) -7F D Barcode Backward-reading Indication None X User defined character( character) -7F D Barcode Direction Indication Transmission Disable Enable prefix direction mark transmission Enable suffix direction mark transmission Enable both prefix and suffix direction mark transmission Scan Rate Control Dynamic Fixed Lateral Reading Disable Enable Scan Rate Control: The scanner will have better motion tolerance when you select Fixed scan rate. It s suitable for application which needs higher motion tolerance on the move. But this may impact to the reading distance. Lateral Reading: Lateral Reading is not a standard function, only available for tailor-made FM48. 55

62 Operation Control FA47 Operation Control, Presentation Background lighting Control Operation Mode Presentation Background Lighting Trigger mode (External triggering) Presentation mode (Auto detection) Alternative mode (Periodic power off) Force mode (Continued power on) Level mode (Auto power off) LEDs Off LEDs On 4 7 Trigger Mode (External Triggering) When the scanner receives an external trigger or a serial trigger ON command under trigger mode, the scanner will turn on the light source to read barcode until gets a good read, a serial trigger OFF command or a release of external trigger. Once the light source goes off, the scanner is waiting for the next trigger to activate scanning again. Presentation Mode (Auto Detection) When presentation mode is selected, the scanner is preset to turn on the background lighting to detect the barcode. Once the scanner detected a similar barcode image, the scanner will turn on the light source to read barcodes until the preset scan input time-out is up. For dark environments, you may adjust the setting of Presentation Sensitivity to increase the detection sensitivity Alternative Mode (Periodic Power Off) When the scanner receives an external trigger or a serial trigger ON command under alternative mode, the scanner will turn on the light source to read barcodes until the preset scan input time-out is up. The scan input time-out will be reset after each good read. Once the light source goes off, the scanner is waiting for the next trigger to activate scanning again. Force Mode (Continued Power On) Under force mode, the scanner continues to read barcodes without using external trigger or serial trigger. Please note that the scanner will not stop reading until you switch into another operation mode. Level Mode (Auto Power Off) When the scanner receives an external trigger or a serial trigger ON command under level mode, the scanner will turn on the light source to read barcodes until a good read is performed or the preset scan input time-out is up. Once the light source goes off, the scanner is waiting for the next trigger to activate scanning again. Hand-Free Mode: Presentation mode, Force mode Presentation Background Lighting Control: You can enable or disable presentation background lighting of the scanner according to the ambient light condition in presentation mode. When the ambient light is dim or dark, you can enable this function to turn on the scanner s LED illumination at a dim level. This is helpful for scanner to detect the motion of scene. 56

63 Operation Control FA47 Aiming Control, Delay Aiming, Illumination Control, Center Alignment & Decode Aiming Control Aiming Control Regular Aiming Intelligent Aiming Delay Aiming Control Delay Aiming Time-out Control ms 4 ms 8 ms sec.5 secs. secs. secs. 4 secs Illumination Control Disable Enable Center Alignment Disable in Hand-Held Mode Enable in Hand-Held Mode Disable in Hand-Free Mode Enable in Hand-free Mode Decode Aiming Control Disable in Hand-Held mode Enable in Hand-Held mode Disable in Hand-Free mode Enable in Hand-Free mode The Aiming Control is only available for trigger mode. In Intelligent Aiming, the aiming light is turned on when the scanner is lifted. A trigger pull activates decoding process. After seconds of inactivity, the aiming light will be shut off. Delay Aiming Control allows a delay time for the operator to aim the scanner before the image is taken. During the delay time, the aiming light will be on, but the LED illumination won t be turned on until the delay time is up. The Delay Aiming Time-out Control is only available for trigger mode. You can use Delay Aiming Time-out Control to set the delay time. The Illumination Control is only available for trigger mode, alternative mode and level mode. Center Alignment: When this function is enabled, the scanner only decodes barcode(s) around aiming line. 57

64 Operation Control FA47 Batch Reading Family Code Selection P.C Unique Bar Code Parameter Reporting, Selection Batch Reading Option Code Batch Reading None Batch Reading rule input ( -6 rules) [] [Rules] [] Batch Reading: When this function is enabled, you can scan multiple barcodes one by one continuously upon one trigger event. The scanner reports a good read beep and indication only if all bar codes set by the Batch Reading Rule are read. Otherwise, the scanner reports an error beep and indication. The scanned data will be transmitted according to the preset sequence which is defined in Batch Reading Rule regardless the scanned order of those barcodes. - Batch Reading function is only available Trigger Mode. - Batch Reading is not available when Multiple Read Mode or Center Alignment is turned on. - Batch Reading Rule: - To set the Batch Reading rule. Scan the symbol.. Scan the Batch Reading symbol (Family Code).. Use the Option Code to define the preset Batch Reading rule. 4. Scan the symbol. 5. Scan the END symbol to save your Batch Reading rule. Note: Scan the ABORT and END symbol to exit without saving any Batch Reading rule setting. - When you scan None, the preset Batch Reading Rule will be cancelled. - Batch Reading Rule Syntax: [n] [Element ] FF [Element ] FF [Element ] FF [Element n] FF Where n is the number of elements in the overall rule. The number of elements is up to 6.FF indicates the end of one element. - Element structure: [Cino ID Hex value] [Code length] [Character match(es)] Where: [Cino ID Hex value] Length: byte Please find Cino ID hex value from Symbology ID Table in appendix. Locate the Hex value for the symbology and scan the digit hex values from the Option Code. Note: 99 is the universal number, indicating all symbologies. 58

65 [Code length] Length: 4 byte Specify what length of data output will be acceptable for this symbology. When you calculate the length, you must consider the whole data string which includes the programmed Preamble, Postamble, Scanned Data Length, Prefix/Suffix Symbol ID or AIM ID. Scan the four digit data length from the Option Code. Note: 4 characters is entered as 4; 9999 is a universal number, indicating all lengths. [Character match] Length: -8 byte You can refer to HEX/ASCII Reference Table to find the Hex value that represents the character(s) you want to match. Use the Option Code to scan the alphanumeric combination that represents the ASCII characters. You can match up to 4 characters which are counted from the start character of the whole Data String. Note: When setting the matched character(s), you must match the content of the whole Data String, including the programmed Preamble, Postamble, Scanned Data Length, Prefix/Suffi Symbol ID OR AIM ID if you had defined. FF is the universal character, indicating all characters. - Batch Reading rule example In this example, you are scanning Code 9, Code 8, and Code 9 bar codes, but you would like to output the data in following sequence: Code 8 - Code 9 - Code 9 B-CODE9 A-CODE8 C-CODE9 59

66 You would set up the Batch Reading rule with the following command line: [] [Batch Reading] [99994FF799994FF999994FF] [] [END] The breakdown of the command line is shown below: The number of elements in the overall rule Code identifier of Code Code length that must match for Code 8, 9999 = all lengths 4 Start character match for Code 8, 4h = A FF End of first code 7 Code identifier of Code Code length that must match for Code 9, 9999 = all lengths 4 Start character that must match for Code 9, 4h = B FF End of second code 9 Code identifier of Code Code length that must match for Code 9, 9999 = all lengths 4 Start character match for Code 9, 4h = C FF End of third code To program the previous example using specific lengths, you would have to count the programmed Preamble, Postamble, Scanned Data Length, Prefix/Suffix Symbol ID OR AIM ID if you had defined as part of the length. If you enable the Suffix Symbol ID of symbology, you would add one character to the previous example s length. You would set up the Batch Reading rule with the following command line: [] [Batch Reading] [4FF79FF994FF] [] [END] 6

67 The breakdown of the command line is shown below: The number of elements in the overall rule Code identifier of Code 8 Code length that must match for Code 8 A-CODE8 sample length (9) plus Suffix Symbol ID () = 4 Start character match for Code 8, 4h = A FF End of first code 7 Code identifier of Code 9 9 Code length that must match for Code 9 B-CODE9 sample length (8) plus Suffix Symbol ID () = 9 FF Universal matched character, indicating all character Also indicate end of second code 9 Code identifier of Code 9 9 Code length that must match for Code 9 C-CODE9 sample length (8) plus Suffix Symbol ID () = 9 4 Start character match for Code 9, 4h = C FF End of third code Note: If the [Character match(es)] is set to FF, the following FF which indicated the end of the code was not need to set. - Structure of Data String STX (RS/USB COM interface) Preamble Scanned Data Length Prefix Symbol ID Or Prefix AIM Symbol ID Scanned Data modified by DataWizard Suffix Symbol ID Or Suffix AIM Symbol ID Postamble ETX (RS/USB COM interface) character -5 characters -4 digits or characters Variable length or characters -5 characters character 6

68 Operation Control FM48, FA47 Buzzer, Indicator, D Barcode Inverse Reading Buzzer Tone Adjust Buzzer tone mute Buzzer tone low (Frequency. khz) Buzzer tone medium (Frequency.7 khz) Buzzer tone high (Frequency.8 khz) Buzzer tone - extremely high (Frequency.9 khz) Power-on beep No power-on beep Power On Indicator Disable (LED off) LED steady on LED flash D Barcode Inverse Reading Disable Enable 6

69 Operation Control (FA47) Buzzer Volume Buzzer Volume Low Medium High Above command is available from FA47 firmware rev..., rev..., and above. 6

70 Operation Control FM48, FA47 Redundancy Redundancy None Level Level Level Level 4 Level 5 To prevent potential miss reading. The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted

71 Operation Control FM48, FA47 Reread Delay & Good Read Delay Setting Reread Delay (Double Scan Verification) Disable Immediate time out Short time out Medium time out Long time out Force verification 4 5 Good Read Delay None msec. 5 msec. sec..5 sec. sec. sec. The Reread Delay (Double Scan Verification) is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification will not allow reading of the same bar code twice. This Good Read Delay is the minimum amount of time before the imager can read another bar code

72 Operation Control FM48, FA47 Time-out and Duration Setting Scan Input Time-out Hands Free Time-out Good Read Duration msec. msec. msec. 4 msec. 5 msec. Short Medium Long Extremely long Disable Short Medium Long Extremely long Extremely short 6 msec. 7 msec. 8 msec. 9 msec. User define: -99 sec , (digits) The Scan Input Time-out is a preset light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The scanner keeps the light source on till the preset light source on time is up. You can adjust this parameter to meet your own application requirement. The presentation mode and force mode will be automatically changed to manual trigger mode when you activate the trigger. You can remain the scanner in manual trigger mode by setting the Hands Free Time-Out. Once the time-out duration is up (if there s no any trigger operation), the scanner will revert to the original presentation or force mode. 4 66

73 Operation Control FM48, FA47 Presentation Sensitivity Presentation Sensitivity Level Level Level Level 4 Level 5 The presentation sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting the barcode. Level 6 Level

74 Operation Control FM48, FA47 OK/NG Signal and Beeping Control OK/NG Signal Active State OK low/ng low OK low/ng high OK high/ng low OK high/ng high OK/NG Signal Output Control Disable OK and NG output Enable NG output Enable OK output Enable OK and NG output NG Message Output None Message NG User defined message (~5 characters),[- 7F] Maximum 5-character input ; scan to terminate this section. OK/NG Signal Duration msec. msec. msec. 4 msec. 5 msec. 6 msec. 7 msec. 8 msec. 9 msec. msec. User define: -99 (x5) msec A, ( digits) OK/NG Beeping Control Disable OK and NG beep Enable OK and NG beep Enable OK beep and disable NG beep Enable NG beep and disable OK beep 68

75 The OK/NG Signal Active State can control the logic level in digit circuits design, you can adjust the active-high or active-low state for OK and NG signal outputs. The OK and NG signals are NPN outputs. The OK/NG Signal Output Control can control the OK/NG signal outputs and OK/NG indications of the scanner. If you disable OK or NG signal output, the scanner OK or NG indication will be disabled. The OK/NG Signal Duration can control the OK/NG signal duration and OK/NG indication duration of the scanner. 69

76 Condensed DataWizard Preamble, Postamble, Data Length & Symbol ID Trans. Preamble None -5 characters [-7F], [] Maximum 5-character input; scan to terminate this selection. Postamble None -5 characters [-7F], [] Maximum 5-character input; scan to terminate this selection. Data Length Transmission Disable Enable digits data length transmission If data length exceeds 99, -digit data length will be transmitted. Symbology ID Transmission Disable symbology ID transmission Enable prefix symbology ID transmission Enable suffix symbology ID transmission Enable both prefix and suffix symbology ID transmission Enable prefix AIM symbology ID transmission Enable suffix AIM symbology ID transmission Enable both prefix and suffix AIM symbology ID transmission DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers. Through DataWizard, you can process the scanned data prior the transmissions in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help you to arrange the transmission of scanned data to any specific format without software modification. Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool. Through the PowerTool, all settings and configurations can be done on-screen, under Windows 95/98/NT//XP environment. A Condensed Version DataWizard is provided by each FuzzyScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with ease. Please note that all Character input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance

77 Condensed DataWizard Data Formatter Setting nd Option Code Formatter Control Disable Select one bar code symbology Select all bar code symbologies ( digits) automatic termination automatic termination st Insertion DS Disable Enable ( digits) [- characters], [] -digits identified position; max. insertion characters position nd Insertion DS Disable Enable ( digits) [- characters], [] -digits identified position; max. insertion characters position rd Insertion DS Disable Enable ( digits) [- characters], [] -digits identified position; max. insertion characters position 4th Insertion DS Disable Enable ( digits) [- characters], [] -digits identified position; max. insertion characters position The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position. While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. All of the above programmable parameters perform the same function depending on your setting. Regarding the Bar Code Selection and Position Calculation of data formatter, please refer to page 49 for details. Please note that all Character input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. 7

78 Condensed DataWizard Data Verifier Setting nd Option Code Verifier Control Disable Select one bar code symbology Select all bar code symbologies ( digits) automatic termination automatic termination Identified Data Length DS Disable Enable ( digits) Determine the identified data length for verification. st Identified Character DS Disable Enable ( digits) [-7F] -digits checking position; identified character position nd Identified Character DS Disable Enable ( digits) [-7F] -digits checking position; identified character position rd Identified Character DS Disable Enable ( digits) [-7F] -digits checking position; identified character position The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter. All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue long beeps for verification error and skip the scanned data. The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. Regarding the Bar Code Selection and Position Calculation of Data Verifier, please refer to page 49 for details. Please note that all Character input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. 7

79 Condensed DataWizard Data Replacer Setting nd Option Code Replacer Control Disable Select one bar code symbology Select all bar code symbologies ( digits) automatic termination automatic termination st Replacement DS Disable Enable ( digits) [-7F] -digits identified position; replacement character position nd Replacement DS Disable Enable ( digits) [-7F] -digits identified position; replacement character position rd Replacement DS Disable Enable ( digits) [-7F] -digits identified position; replacement character position The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for replacer control, and provides Multiple Position Replacement in the identified position. All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position While the Data Replacer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. Regarding the Bar Code Selection and Position Calculation of Data Replacer, please refer to page 49 for details. Please note that all Character input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. 7

80 Condensed DataWizard Data Organizer Setting nd Option Code Organizer Control Disable Select one bar code symbology Select all bar code symbologies ( digits) automatic termination automatic termination st Organization DS Disable Enable -digits identified position; Forward/backward data transmission setting ( digits) position direction (Forward) (Backward) nd Organization DS Disable Enable -digits identified position; Forward/backward data transmission setting ( digits) position direction (Forward) (Backward) Include/Exclude Control DS Transmitted data excluded the data of identified position Transmitted data included the data of identified position The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward. It also allows you to control the transmitted data including or excluding the data of identification position. Please refer to the application example listed in page 7 for details. While the Data Organizer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. Regarding the Bar Code Selection and Position Calculation of Data Organizer, please refer to page 49 for details. Please note that all Character input should be referred to the ASCII/HEX Table. 74

81 Select a Bar Code Symbology You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan to select all types, the FuzzyScan will arrange all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option code listed below. D Bar Code Symbology Code 8 Matrix of 5 8 GS-8 Interleaved of 5 48 UPC-A China Postal Code 58 UPC-A with supplement German Postal Code 68 UPC-A with 5 supplement 4 Standard/Industrial of 5 8 UPC-E Code 9 9 UPC-E with supplement Code UPC-E with 5 supplement 4 I/Plessey EAN- 4 UK/Plessey EAN- with supplement 4 Telepen EAN- with 5 supplement 44 GS DataBar 4 EAN-8 5 GS DataBar Limited EAN-8 with supplement 5 GS DataBar Expanded EAN-8 with 5 supplement 45 Composite Codes 4 Codabar/NW-7 6 IATA 5 Code 9 7 Coupon Code 6 Code 7 PDF47 7 Trioptic Code 9 47 Micro PDF47 5 Codablock F 8 Code 6K 9 Code 49 D Bar Code Symbology QR Code A MaxiCode A MicroQR Code A Aztec Code A DataMatrix A Chinese Sensible Code A4 GS DataMatrix A5 Postal Code Korea Post Code Japanese Post B4 Australian Post B KIX Post B5 British Post B Planet Code B6 Intelligent Mail barcode B Postnet B8 Position Calculation [Data Formatter] If there is a 5-character input data string, refer to the following to calculate the actual position for insertion: X X X X X 4 5 [Data Verifier, Data Replacer, Data Organizer] If there is a -character data string, please refer to the following to calculate the actual position for identification. X X X X X X X X X X X

82 Programming Procedure [Data Verifier] Application Example If your bar code label is a 6-digit Interleaved of 5 which includes the information of 6-digit date code, 6-digit serial number and 4-digit unit price, you want the FuzzyScan do the following for you without software modification: Apply only Interleaved of 5 to the condensed DataWizard. Check bar code is actually with 6-digit length. Allow bar code output whose date code is leading with 9. Three outputs with TAB suffix. The date code output should skip 9 and replaced it by A. The serial number output should be led with SN. The unit price output should be skipped the first digits. Test Bar Code : Actual Output : A85[TAB]SN456[TAB]76[TAB] Scan Program to enter the programming mode. Scan Verifier Control and set bar code symbology to 48 (Interleaved of 5). Scan Identified Data Length and set the length to 6. Scan st Identified Character and set the identified position to, then set the identified character to 9 (Hex Code of 9). [Data Formatter] Scan Formatter Control and set bar code symbology to 48. Scan st Insertion and set the identified position to 6, then inserted characters to 9 (Hex Code of TAB), 5 (Hex Code of S), 4E (Hex Code of N). Scan nd Insertion and set the identified position to, then inserted character to 9. In the final, you must scan (Finish) code to terminate this selection. Scan rd Insertion and set the identified position to 6, then inserted character to 9. In the final, you must scan (Finish) code to terminate this selection. 76

83 [Data Replacer] Scan Replacer Control and set bar code symbology to 48. Scan st Replacement and set the identified position to, then replaced character to 4 (Hex Code of A). [Data Organizer] Scan Organizer Control and set bar code symbology to 48. Scan st Organization and set the identified position to 6, then set the data transmission to (forward). Scan nd Organization and set the identified position to 7, then set the data transmission to (backward). Scan END (Exit) to terminate the programming. [Important Notice] Please note that Condensed DataWizard will follow the preset working flow as below: Verifier Formatter Replacer Organizer So when you set the identified position in Data Organizer, you must consider the inserted data which you already set via Data Formatter.. 77

84 Symbology ID Table Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character; c = Code Character; m = Modifier Character D Symbology ID Table Code Family UPC Code 8 Primary Format Hex Value UPC-A Cino ID Char. Code Char. AIM ID Modified Char. Code Family Primary Format UPC-A with supple. A EAN/JAN-8 with supple. 5 N E UPC-A with 5 supple. 4 EAN/JAN-8 with 5 supple. 45 E EAN/JAN UPC-E EAN/JAN- 4 Hex Value EAN/JAN-8 5 UPC-E with supple. E EAN/JAN- with supple. 4 F E UPC-E with 5 supple. 4 EAN/JAN- with 5 supple. 44 Example: A UPC-A bar code with supplement is transmitted as ]E ]E Cino ID Char. Code Char. AIM ID Modified Char. Example: A EAN/JAN-8 bar code 4956 with 5 supplement 45 is transmitted as ]E44956]E45 Code 8 B m Code 9 Code 9 9 H G m C GS-8 C Code Code P H m Codabar Codabar/NW-7 6 D F m I/Plessey I/Plessey R M m Code 5 Standard/Industrial of 5 8 I S UK/Plessey UK/Plessey S P Matrix of 5 8 K X Telepen Telepen T B m Interleaved of 5 48 J I m GS DataBar China Postal Code 58 L X GS Databar 4 GS DataBar Limited GS DataBar Expanded Composite Composite Code 4 4 X e m Code 9 7 G A m German Postal Code 68 M I m Code 9 Code 9 Trioptic 47 W X IATA IATA 5 O R m Code 7 G A UCC Coupon UCC Coupon Code Example : A UPC-A GS bar code is transmitted as]e ]c84597 Example: A EAN GS bar code is transmitted as ]E ]C84597 Z PDF47 PDF47 7 Micro PDF47 5 V L m Codablock Codablock F 8 Y O m Korea Post Korea Post Code a X Remark: Above examples are given for the transmission of AIM ID. 78

85 Code Family QR Code Micro QR Code Data Matrix QR Code Primary Format Micro QR Code Data Matrix GS Data Matrix Hex Value Cino ID Char. Code Char. D Symbology ID Table AIM ID Modified Char. A b Q m A A5 c d m Code Family Primary Format Hex Value Cino ID Char. British Post British Post B h Intelligent Mail barcode Japanese Post Intelligent Mail barcode Code Char. AIM ID Modified Char. B j Japanese Post B4 k X MaxiCode MaxiCode A d U m KIX Post KIX Post B5 l Aztec Code Aztec Code A e z m Planet Code Planet Code B6 m Chinese Chinese Sensible A4 f Postnet Postnet B8 o Sensible X Australian Post Australian Post B g 79

86 Keyboard Function Code Table No. ANSI ASCII Key Function Ctrl Output No. ANSI ASCII Key Function Ctrl Output NUL H RESERVED Ctrl 6 DLE H F7 Ctrl + P SOH H CTRL (Left) Ctrl + A 7 DC H F8 Ctrl + Q STX H ALT (Left) Ctrl + B 8 DC H F9 Ctrl + R ETX H SHIFT Ctrl + C 9 DC H F Ctrl + S 4 EOT 4H CAPS LOCK Ctrl + D DC4 4H F Ctrl + T 5 ENQ 5H NUM LOCK Ctrl + E NAK 5H F Ctrl + U 6 ACK 6H ESC Ctrl + F SYN 6H INS (Insert) (Edit) Ctrl + V 7 BEL 7H F Ctrl + G ETB 7H DEL (Delete) (Edit) Ctrl + W 8 BS 8H BACK SPACE Ctrl + H 4 CAN 8H HOME (Edit) Ctrl + X 9 HT 9H TAB Ctrl + I 5 EM 9H END (Edit) Ctrl + Y LF AH F Ctrl + J 6 SUB AH PAGE UP (Edit) Ctrl + Z VT BH F Ctrl + K 7 ESC BH PAGE DOWN (Edit) Ctrl + [ FF CH F4 Ctrl + L 8 FS CH UP (Edit) Ctrl + \ CR DH ENTER (CR) Ctrl + M 9 GS DH DOWN (Edit) Ctrl + ] 4 SO EH F5 Ctrl + N RS EH LEFT (Edit) Ctrl SI FH F6 Ctrl + O US FH RIGHT (Edit) *see note To emulate the keyboard function key input for user definable parameters, user must configure actual content using the Reserved ASCII characters, and also Enable the Function Key Emulation. Otherwise, the Ctrl output will be done by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/, PS/VP, COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines. The last character in the Ctrl Output column is varied for different countries. Country (refer to Keyboard Layout) & Character United State - Switzerland - France = Belgium - UK - Germany - Sweden - Denmark - Norway - Spain - Italy - 8

87 ASCII Input Shortcut To configure the user definable parameters of FuzzyScan via programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the HEX/ASCII Table for details. Example: If you want the scanned data output leading with a Dollar Sign, you have to set the Preamble to $. The configuration procedure is listed below for reference. Scan the system command listed on page -4 to enter programming mode. Scan family code PREAMBLE to select this family. Refer to the Hex/ASCII Table, you will find the HEX value of $ is 4. Scan the option code listed on the fold out back cover. Scan the option code 4 listed on the fold out back cover. Scan the system command (Finish) to terminate Preamble setting. Scan the system command End to exit the programming mode for normal operation. HEX/ASCII Reference Table H L NUL DLE P ` p SOH DC! A Q a q STX DC " B R b r ETX DC # C S c s 4 EOT DC4 $ 4 D T d t 5 ENQ NAK % 5 E U e u 6 ACK SYN & 6 F V f v 7 BEL ETB ' 7 G W g w 8 BS CAN ( 8 H X h x 9 HT EM ) 9 I Y i y A LF SUB * : J Z j z B VT ESC + ; K [ k { C FF FS, < L \ l D CR GS - = M ] m } E SO RS. > N ^ n ~ F SI US /? O _ o DEL Example : ASCII A HEX 4 ; ASCII a 6 : High Byte of HEX Value : Low Byte of HEX Value 8

88 Host Interface Quick Set RS Serial USB Com Port Emulation USB HID Standard Mode USB HID Turbo Mode Operation Mode Quick Set FM48 Trigger Mode Force Mode (Continued power on) Alternative Mode (Periodic power off) Presentation Mode (Auto sensing) Level Mode (Auto power off) 8

89 Operation Mode Quick Set FA47 Trigger Mode Force Mode (Continued power on) Alternative Mode (Periodic power off) Presentation Mode (Auto sensing) Level Mode (Auto power off) 8

90 Option Codes A 5 F B 6 C 7 D 8 4 E 9 (Finish) Abort END (Exit) 84

91 System Commands (Enter Programming Mode) System Information List (SYSLIST) Save User Default (Finish) PowerTool Host Link User Default END (Exit Programming Mode) Factory Default Master Default Factory Default: After scanning Factory Default command, all parameters will be returned to factory default value. Master Default: After scanning Master Default command, the scanner will remain the pre-set parameters of Host Interface Selection, Keyboard Interface Control (except Record Suffix; Preamble; Postamble), Serial Interface Control (except Record Suffix; Preamble; Postamble), and Wand/Laser Emulation Control, the rest of parameters will be returned to default value. User Default: After scanning Save User Default command, all current parameters will be stored to the flash memory. Once you change the parameter and would like to return to previous setting, please scan User Default. 85

92 Indications Power Indicator Status Indicator OK/NG Indicator FM48 FA47 Normal Operation Descriptions Indicators Power Status OK/NG Beeper Power on Steady blue Off Off Power on beep Good read (OK reading) Off Off green blink good read beep No read (NG reading) Off Off red blink no read beep Intelli Button Reading Rate Information Reading Rate Indicators Power Status OK/NG % Steady Green Steady Green 8 to 99% Steady Red Steady Green 5 to 79% blue blink per sec. Steady Green Steady Red to 49% Steady Orange Steady Orange to 9% Steady Red Steady Red Beeper One short beep 86

93 87

FIXED MOUNT SCANNER. Programming Manual International Edition, Rev. B1

FIXED MOUNT SCANNER. Programming Manual International Edition, Rev. B1 FIXED MOUNT SCANNER International Edition, Rev. B Revision History Rev. No. Released Date Description Rev. A May 6, First Release Rev. A Jun. 8, Page 6 Page 8 Add UPC/EAN Security Level Add Immediate parameter

More information

International Edition, Rev. D13

International Edition, Rev. D13 International Edition, Rev. D Revision History Rev. No. Released Date Description Rev.B Beta Apr. 6, 9 First Release Rev.B May 5, 9 Modify Symbology Reading Control - Code 8/EAN-8 Setting and GS DataBar

More information

International Edition, Rev. D15

International Edition, Rev. D15 International Edition, Rev. D5 Revision History Rev. No. Released Date Description Rev.B Beta Apr. 6, 9 First Release Rev.B May 5, 9 Modify Symbology Reading Control - Code 8/EAN-8 Setting and GS DataBar

More information

BARCODE IMAGER. Programming Manual International Edition, Rev. D7

BARCODE IMAGER. Programming Manual International Edition, Rev. D7 BARCODE IMAGER International Edition, Rev. D7 Revision History Rev. No. Released Date Description Rev.B Beta Apr. 6, 9 First Release Rev.B May 5, 9 Page Code 8/EAN-8 Setting Modify ISBT Concatenation Off

More information

USER'S GUIDE HANDHELD SCANNER IMS-3190

USER'S GUIDE HANDHELD SCANNER IMS-3190 USER'S GUIDE HANDHELD SCANNER I-9 Getting Started Table of Contents Getting Familiar with Your Proton I 9 Preparation before Using Decide Your Radio Link Mode Use Proton I 9 in PAIR Mode 4 Use Proton I

More information

BARCODE IMAGER. Programming Manual International Edition, Rev. C6

BARCODE IMAGER. Programming Manual International Edition, Rev. C6 BARCODE IMAGER International Edition, Rev. C6 Revision History Rev. No. Released Date Description Rev.B Beta Apr. 6, 9 First Release Rev.B May, 9 Page Code 8/EAN-8 Setting Modify ISBT Concatenation Off

More information

WIRELESS IMAGER. Reference Manual. International Edition, Rev. A9

WIRELESS IMAGER. Reference Manual. International Edition, Rev. A9 WIRELE IMAGER International Edition, Rev. A9 Revision History Rev. No. Released Date Description Rev. A Oct 6, 9 First Release Rev. A Oct, 9 Page 6 Page 68 Revise Clone Function operation method. Add Save

More information

BARCODE IMAGER. Programming Manual International Edition, Rev. B7

BARCODE IMAGER. Programming Manual International Edition, Rev. B7 BARCODE IMAGER International Edition, Rev. B7 Revision History Rev. No. Released Date Description Rev.B Beta Apr. 6, 9 First Release Rev.B May 5, 9 Page Code 8/EAN-8 Setting Modify ISBT Concatenation Off

More information

Getting Familiar with Your FuzzyScan

Getting Familiar with Your FuzzyScan Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Imager. All FuzzyScan imagers deliver world-class performance for a broad range of applications to unleash your productivity.

More information

WIRELESS IMAGER Reference Manual

WIRELESS IMAGER Reference Manual WIRELE IMAGER International Edition, Rev. C Revision History Rev. No. Released Date Description Rev. A Oct 6, 9 First Release Rev. A Oct, 9 Page 6 Page 68 Revise Clone Function operation method. Add Save

More information

International Edition, Rev C9

International Edition, Rev C9 International Edition, Rev C9 Revision History Rev. No. Released Date Description Rev. A Oct 6, 9 First Release Rev. A Oct, 9 Modified Getting Started - Clone Function operation method. Added Appendix

More information

DelfiScan C70. Programming Manual

DelfiScan C70. Programming Manual DelfiScan C7 Programming Manual Table of Contents Getting Started Getting Familiar with your DelfiScan Connecting/Disconnecting Cable Connecting Host Interface 4 Configure Your DelfiScan Bar Code Programming

More information

BARCODE SCANNER. FUZZYSCAN FAMILY Quick Start Guide

BARCODE SCANNER. FUZZYSCAN FAMILY Quick Start Guide BARCODE SCANNER FUZZYSCAN FAMILY Quick Start Guide Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Bar Code Scanner. All FuzzyScan scanners deliver world-class performance for

More information

Configure Your FuzzyScan

Configure Your FuzzyScan Configure Your FuzzyScan A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding Before you trying to configure the FuzzyScan, you must refer to the Quick Installation chapter of reading devices

More information

FA470 Series. A future-proof area-imaging fixed mount scanner for boosting enterprise s productivity

FA470 Series. A future-proof area-imaging fixed mount scanner for boosting enterprise s productivity FA470 Series A future-proof area-imaging fixed mount scanner for boosting enterprise s productivity Powered by FuzyScan 3.0 imaging technology, IP54 ultra-compact yet durable over-molded construction,

More information

Bluetooth Version FUZZYSCAN FAMILY. Quick Start Guide CORDLESS SCANNER

Bluetooth Version FUZZYSCAN FAMILY. Quick Start Guide CORDLESS SCANNER CORDLESS SCANNER Bluetooth Version FUZZYSCAN FAMILY Quick Start Guide Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Bluetooth Cordless Image Scanner. Powered by the combination

More information

International Edition, Rev C18

International Edition, Rev C18 International Edition, Rev C8 Revision History Rev. No. Released Date Description Rev. A Oct 6, 9 First Release Rev. A Oct, 9 Modified Getting Started - Clone Function operation method. Added Appendix

More information

IDM1xx Bluetooth Hand-held Scanners

IDM1xx Bluetooth Hand-held Scanners MING MANUAL IDMxx Bluetooth Hand-held canners Hand-held Line Revision History Rev. No. Released Date Description Rev. A Jan., First Release Rev. A Mar., Rev.A Jun., Modify UPC-E/EAN-8 expansion and UPC-A

More information

2D Imaging Barcode Scanner GLLS. Programming Guide. Advanced Handheld High-Speed Laser Scanner

2D Imaging Barcode Scanner GLLS. Programming Guide. Advanced Handheld High-Speed Laser Scanner 2D Imaging Barcode Scanner GLLS Programming Guide 1 Advanced Handheld High-Speed Laser Scanner Revision History Changes to the original manual are listed below: Version Date Description of Version 1.0

More information

2D BARCODE SCANNER CA-SC-20200B

2D BARCODE SCANNER CA-SC-20200B D BARCODE SCANNER CA-SC-B Quick Start Guide Getting Familiar with Your Device Thank you for choosing Capture Bar Code Scanner. All Devices deliver world-class performance for a broad range of applications

More information

Area Imager Bar Code Scanner 2 D C O N F I G U R A T I O N G U I D E

Area Imager Bar Code Scanner 2 D C O N F I G U R A T I O N G U I D E Area Imager Bar Code Scanner 2 D C O N F I G U R A T I O N G U I D E Copyright @ 2017 This manual is copyrighted, with all right reserved. Under the copyright laws, this manual may not, in whole or in

More information

530-2D-USB 2D Scanner High Speed Imaging USB Bar Code Scanner

530-2D-USB 2D Scanner High Speed Imaging USB Bar Code Scanner 530-2D-USB 2D Scanner High Speed Imaging USB Bar Code Scanner Worth Data USB 2D Bar Code Scanner - Scan 1D & 2D Matrix Bar codes www.worthdata.com Owner s Manual Warning: This equipment generates, uses

More information

BARCODE SCANNER. Configuration Guide - 1 -

BARCODE SCANNER. Configuration Guide - 1 - BARCODE SCANNER Configuration Guide - 1 - Table of Contents Chapter 1 System Information 1.1 About this manual 3 1.2 How to set up the parameter 3 1.3 How to set up the parameter - II 4 Chapter 2 System

More information

2D Scan Engine Confguration Guide. 2D Barcode Scanner Configration Guide

2D Scan Engine Confguration Guide. 2D Barcode Scanner Configration Guide 2D Barcode Scanner Configration Guide 1 Table of Contents USB Settings USB Keyboard Mode...6 (A1) USB Downloader Mode...6 (A2) USB Virtual COM One Way Mode...6 (A3) USB Native Two Way Mode...6 (A4) USB

More information

Serial Command Manual. International Edition Rev.A6

Serial Command Manual. International Edition Rev.A6 Serial Command Manual International Edition Rev.A6 Revision History Merged all the CMD Manuals of different series into one Manual Added command TS A Operation Mode Flash, Force, Toggle, and Diagnostic

More information

NC-1200 BARCODE SCANNER. Configuration Guide - 1 -

NC-1200 BARCODE SCANNER. Configuration Guide - 1 - NC-1200 BARCODE SCANNER Configuration Guide - 1 - Table of Contents Chapter 1 System Information 1.1 About this manual 3 1.2 How to set up the parameter-i 3 1.3 How to set up the parameter II 4 1.4 Resetting

More information

Code Reader 1000/1400/8000 Configuration Guide

Code Reader 1000/1400/8000 Configuration Guide Code Reader 1000/1400/8000 Configuration Guide Code Reader 1000 Code Reader 1400 Code Reader 8000 1 Table of Contents USB Settings USB Keyboard Mode...6 (A1) USB Downloader Mode...6 (A2) USB Virtual COM

More information

Nuscan 3200 Optical Laser Barcode Scanner

Nuscan 3200 Optical Laser Barcode Scanner Nuscan 3200 Optical Laser Barcode Scanner Programming Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC

More information

CR2300 CR2600 CR3600 (DPM)

CR2300 CR2600 CR3600 (DPM) CONFIGURATION GUIDE ENGLISH CR2300 CR2600 CR3600 (DPM) CONFIGURATION GUIDE: VERSION 12 SUPPORTED FIRMWARE: READERS 0956+, MODEM 2000+ RELEASE DATE: SEPTEMBER 2014 www.codecorp.com User Manuals YouTube.com/codecorporation

More information

DS6707 Digital Imager Scanner. Product Reference Guide

DS6707 Digital Imager Scanner. Product Reference Guide Symbol DS6707 Product Reference Guide Manual DS6707 Digital Imager Scanner Product Reference Guide Table of Contents Revision History... iii About This Guide Introduction... xv Configurations... xv Chapter

More information

2D Imaging Barcode Scanner GLLS. Programming Guide. Advanced Handheld High-Speed Laser Scanner

2D Imaging Barcode Scanner GLLS. Programming Guide. Advanced Handheld High-Speed Laser Scanner 2D Imaging Barcode Scanner GLLS Programming Guide 1 Advanced Handheld High-Speed Laser Scanner Revision History Changes to the original manual are listed below: Version Date Description of Version 1.0

More information

NCR Realscan 7837 High-Performance Scanners. User s Guide Issue A

NCR Realscan 7837 High-Performance Scanners. User s Guide Issue A NCR Realscan 7837 High-Performance Scanners User s Guide 497-0427357 Issue A Table of Contents Chapter 1 - Getting Started About This Manual... 1-1 Unpacking the Scanner... 1-2 RealScan 7837 High-Performance

More information

MP720 Presentation Imager

MP720 Presentation Imager MP720 Presentation Imager User Manual Version: MP720_UM_EN_V1.1.3 Notice Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. 1. All software, including firmware,

More information

Configuration Guide. Code Reader C005435_02_CR1000_CR8000_ConfigurationGuide 1

Configuration Guide. Code Reader C005435_02_CR1000_CR8000_ConfigurationGuide 1 Code Reader 1000/8000 Configuration Guide Code Reader 1000 Code Reader 8000 C005435_02_CR1000_CR8000_ConfigurationGuide 1 Table of Contents USB Settings USB Keyboard Mode...6 (A1) USB Downloader Mode...6

More information

MP168 Screen Barcode Image Platform

MP168 Screen Barcode Image Platform MP168 Screen Barcode Image Platform User Manual Version: MP168_UM_EN_V1.1.1 Notice Ensure that the optional DC adapter works at + 5 VDC, especially for the RS-232 interface cable. 1. All software, including

More information

Code Reader 1000/1400/8000 Configuration Guide

Code Reader 1000/1400/8000 Configuration Guide Code Reader 1000/1400/8000 Configuration Guide Code Reader 1000 Code Reader 1400 Code Reader 8000 1 Table of Contents USB Settings USB Keyboard Mode...6 (A1) USB Downloader Mode...6 (A2) USB Virtual COM

More information

MD60xx Image Barcode Scanner

MD60xx Image Barcode Scanner MD60xx Image Barcode Scanner User Manual Version: MD60xx_UM_EN_V1.1.2 Notice Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. 1. All software, including firmware,

More information

If you want to have other configurations please refer to below programming barcodes. Check Scanner Version

If you want to have other configurations please refer to below programming barcodes. Check Scanner Version NT-1228BL V18.7.12 Quick Setup Guide This model can work both via USB cable or via bluetooth. Connection Mode Working via USB cable Get Started: Connect scanner with your device via USB cable. If you use

More information

510-2d Complete Configuration Guide Worth Data Inc. 05/2010

510-2d Complete Configuration Guide Worth Data Inc. 05/2010 510-2d Complete Configuration Guide Worth Data Inc. 05/2010 i User Preferences Table 5-1. User Preferences Default Table Parameter Parameter Number Default Page Number User Preferences Set Default Parameter

More information

MD65xx Image Barcode Scanner

MD65xx Image Barcode Scanner MD65xx Image Barcode Scanner User Manual Version: MD65xx_UM_EN_V1.1.1 Warning: Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. NOTICE: 1. All software, including

More information

USER MANUAL. ZKB200 Handheld Image Scanner. Version:1.0 Date: April, 2018

USER MANUAL. ZKB200 Handheld Image Scanner. Version:1.0 Date: April, 2018 USER MANUAL ZKB200 Handheld Image Scanner Version:1.0 Date: April, 2018 Notice Ensure that the optional DC adapter works at +5 VDC, especially for the RS-232 interface cable. 1. All software, including

More information

Introduction. Installation- Keyboard Wedge

Introduction. Installation- Keyboard Wedge Introduction Installation- Keyboard Wedge 1) First of all, you must switch off power for the terminal/computer. 2) Disconnect the keyboard cable from the back of the terminal/computer. 3) Connect the appropriate

More information

Wireless Laser Barcode Scanner ils 6300BU. User s Manual

Wireless Laser Barcode Scanner ils 6300BU. User s Manual Wireless Laser Barcode Scanner ils 6300BU User s Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.

More information

MK D Imager Barcode Scanner Configuration Guide

MK D Imager Barcode Scanner Configuration Guide MK-5500 2D Imager Barcode Scanner Configuration Guide V1.4 Table of Contents 1 Getting Started... 3 1.1 About This Guide... 3 1.2 Barcode Scanning... 3 1.3 Factory Defaults... 3 2 Communication Interfaces...

More information

2D barcode scanner User Manual

2D barcode scanner User Manual 2D barcode scanner User Manual V1.1 2013/06/08 Table of Contents Introduction... 4 Interface Settings... 4 RS232 Serial Port... 4 USB Interface Settings... 5 RS232 Settings... 6 Keyboard Settings... 9

More information

Advanced Data Formatting (ADF) Programmer Guide

Advanced Data Formatting (ADF) Programmer Guide Advanced Data Formatting (ADF) Programmer Guide Advanced Data Formatting Programmer Guide 72E-69680-02 Revision A April 2009 ii Symbol DS3407 Product Reference Guide 2009 by Motorola, Inc. All rights

More information

User s Guide. Linear Imager

User s Guide. Linear Imager User s Guide 3200 Linear Imager Disclaimer Hand Held Products, Inc. ( Hand Held Products ) reserves the right to make changes in specifications and other information contained in this document without

More information

SIMATIC Ident Handheld reading systems SIMATIC MV325 Configuration guide Compact User Manual

SIMATIC Ident Handheld reading systems SIMATIC MV325 Configuration guide Compact User Manual SIMATIC Ident Handheld reading systems Compact User Manual Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to

More information

2D Barcode Reader User Guide V 1.2.1

2D Barcode Reader User Guide V 1.2.1 2D Barcode Reader User Guide V 1.2.1 Table of Contents 1 Getting Started... 3 1.1 About This Guide... 3 1.2 Barcode Scanning... 3 1.3 Factory Defaults... 3 1.4 Firmware Version Number... 3 2 Communication

More information

Area Imager Bar Code Scanner

Area Imager Bar Code Scanner Area Imager Bar Code Scanner 2 D C O N F I G U R A T I O N G U I D E SYMBOLOGY PROGRAMMING for POCKET SCANNERS Copyright @ 2017 This manual is copyrighted, with all right reserved. Under the copyright

More information

If you want to do other configurations please refer to below programming barcodes.

If you want to do other configurations please refer to below programming barcodes. NT-1202 Quick Setup Guide This is 1D&2D plug and play model if you use a US keyboard. If you use other type of keyboard, plug the USB cable on your device, setup keyboard language before you use it. (refer

More information

Barcode Scanner. Model no. NuScan User s Manual

Barcode Scanner. Model no. NuScan User s Manual Barcode Scanner Model no. NuScan 5000 User s Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.

More information

El5220. Image Platform. User Manual

El5220. Image Platform. User Manual El5220 Image Platform User Manual Version: El5220 _UM_EN_V1.1.3 NOTICE Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. 1. All software, including firmware,

More information

If you want to do other configurations please refer to below programming barcodes.

If you want to do other configurations please refer to below programming barcodes. NT-W8 V18.9.1 Quick Setup Guide This model can work both via USB cable or 2.4G receiver. Connection Mode Working via USB cable Get Started: Connect scanner with your device via USB cable. If you use US

More information

MP80xx Image Platform

MP80xx Image Platform MP80xx Image Platform User Manual Version: MP80xx_UM_EN_V1.1.3 NOTICE Warning: Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. 1. All software, including firmware,

More information

Advanced Handheld High-Speed Laser Scanner

Advanced Handheld High-Speed Laser Scanner GLLS 1 Advanced Handheld High-Speed Laser Scanner Revision History Changes to the original manual are listed below: Version Date Description of Version 1.0 2015/03/03 Initial release 1.1 2015/04/15 Added

More information

Getting Started Setup Procedures

Getting Started Setup Procedures Getting Started ------------------------------------------------------------2 Setup Procedures ---------------------------------------------------------3 Setup Menu----------------------------------------------------------------

More information

1504 Barcode Scanner. Setup barcodes included. Version 1.00

1504 Barcode Scanner. Setup barcodes included. Version 1.00 1504 Barcode Scanner Setup barcodes included. Version 1.00 Copyright 2011 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under

More information

Product Engineering Specification Scan Utility

Product Engineering Specification Scan Utility Product Engineering Specification Scan Utility Overview: 1. What is Scan Utility? Scan Utility provides a user interface that communicates with the scanner. It can set up the scanner, download the scanner

More information

Leitor Zebra LI

Leitor Zebra LI Leitor Zebra LI4278 Criado para uso diário e contínuo, o LI4278 oferece liberdade sem fio, compatível com Bluetooth. Oferece também uma melhor criptografia para uma segurança aprimorada e um melhor desempenho

More information

Code Interleaved 2 of 5. Plessey Minimum And Plessey Maximum Length. Field Size/Char. Enabled.

Code Interleaved 2 of 5. Plessey Minimum And Plessey Maximum Length. Field Size/Char. Enabled. Chapter 5: Configuration Decoded (HHP) Plessey Minimum And Plessey Maximum Length These parameters apply to Plessey bar codes.the length of a code refers to the number of characters (i.e., human readable

More information

Table of Contents Sleep Settings How to Configure the Scanner. 7 Chapter 2 System Setup

Table of Contents Sleep Settings How to Configure the Scanner. 7 Chapter 2 System Setup Table of Contents Chapter 1 System Information 1.1 Setup Scanner with PC 1.2 Setup Scanner with Mobile Device 1.3 Configure ios On-Screen Keyboard 1.4 Memory Mode 3 4 4 5 1.5 Sleep Settings 6 1.6 How to

More information

MD22xx Barcode Scanner

MD22xx Barcode Scanner MD22xx Barcode Scanner User Manual Version: MD2250_UM_EN_V3.2.18 NOTICE Ensure that the optional DC adapter works at +5 VDC, especially for the RS-232 interface cable. 1. All software, including firmware,

More information

PureScan - ML1. Configuration Guide. Wireless Linear Imager Wireless Laser scanner - 1 -

PureScan - ML1. Configuration Guide. Wireless Linear Imager Wireless Laser scanner - 1 - PureScan - ML1 Wireless Linear Imager Wireless Laser scanner Configuration Guide - 1 - Table of Contents Chapter 1 System Information 1.1 About this manual 3 1.2 How to set up the parameter 3 Chapter 2

More information

AUTOID WEARABLE RING SCANNER DATA COLLECTOR

AUTOID WEARABLE RING SCANNER DATA COLLECTOR AUTOID WEARABLE RING SCANNER DATA COLLECTOR PRODUCT SPECIFICATION V1.4 1. AUTOID RING SCANNER PERFORMANCE CHARACTERISTICS Operating System RAM, ROM Expansion Slot Interface/Communication Keyboard Display

More information

MD22xx Barcode Scanner

MD22xx Barcode Scanner MD22xx Barcode Scanner User Manual Version: MD22xx_UM_EN_V3.2.17 NOTICE Ensure that the optional DC adapter works at +5 VDC, especially for the RS-232 interface cable. 1. All software, including firmware,

More information

Disclaimer. Please read through the manual carefully before using the product and operate it

Disclaimer. Please read through the manual carefully before using the product and operate it ONEBRAND,ONESOLUTI ON 2D Handhel dbar codescanner UserManual Disclaimer Please read through the manual carefully before using the product and operate it according to the manual. It is advised that you

More information

CD D Image Scanner Advanced Manual

CD D Image Scanner Advanced Manual CD-3200 2D Image Scanner Advanced Manual Version: A0 Contents INTRODUCTION... - 1-1. GENERAL OPTIONS... - 5-1.1. Restore to Factory Default Settings... - 5-1.2. Switch User Interface and Reset to Default

More information

Wi-Fi Barcode Scanner

Wi-Fi Barcode Scanner Wireless Wi-Fi Barcode Scanner A world-class Wi-Fi barcode scanner for enterprise WLAN connectivity Thanks to the convergence of the cutting-edge FuzzyScan 3.0 Imaging Technology and IEEE 802.11 wireless

More information

SPEECHMIKE TM PHI BARCODE READER PROGRAMMING MANUAL PRO READER

SPEECHMIKE TM PHI BARCODE READER PROGRAMMING MANUAL PRO READER SPEECHMIKE TM PRO READER 6184 BARCODE READER PROGRAMMING MANUAL PHI CONTENTS Getting Started -------------------------------------------------------------- 2 Setup Procedures ------------------------------------------------------------3

More information

Installation- Keyboard Wedge

Installation- Keyboard Wedge 0 Introduction Installation- Keyboard Wedge 1) First of all, you must switch off power for the terminal/computer. 2) Disconnect the keyboard cable from the back of the terminal/computer and connect to

More information

Code Reader 2300/2600/3600/CR3600 DPM Configuration Guide

Code Reader 2300/2600/3600/CR3600 DPM Configuration Guide Code Reader 2300/2600/3600/CR3600 DPM Configuration Guide 1 Table of Contents Modem Settings (for use with the Charging Station with an Embedded CodeXML Modem or the external CodeXML M3 Modem when paired

More information

Laser Barcode Scanner Model no. LS6007 FS5027

Laser Barcode Scanner Model no. LS6007 FS5027 Laser Barcode Scanner Model no. LS6007 FS5027 User s Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC

More information

Preliminary draft_1. Prefix Scanned Data Suffix. Intercharacter Delay. Intercharacter Delay

Preliminary draft_1. Prefix Scanned Data Suffix. Intercharacter Delay. Intercharacter Delay Clear One Suffix Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal.

More information

Code Reader 2300/2600 Configuration Guide

Code Reader 2300/2600 Configuration Guide Code Reader 2300/2600 Configuration Guide 1 Table of Contents Modem Settings (for use with the Charging Station with an Embedded CodeXML Modem or the external CodeXML M3 Modem when paired with a CR2300/CR2600)

More information

2 D C O N F I G U R A T I O N G U I D E B T S C A N N E R

2 D C O N F I G U R A T I O N G U I D E B T S C A N N E R Area Imager Bar Code Scanner 2 D C O N F I G U R A T I O N G U I D E B T S C A N N E R Copyright @ 2018 This manual is copyrighted, with all right reserved. Under the copyright laws, this manual may not,

More information

AsReader Gun(ASR-R250G) AsReader Combo(ASR-023xD/ASR-0240D) Barcode Setting Manual

AsReader Gun(ASR-R250G) AsReader Combo(ASR-023xD/ASR-0240D) Barcode Setting Manual AsReader Gun(ASR-R250G) AsReader Combo(ASR-023xD/ASR-0240D) Barcode Setting Manual AsReader, Inc. Ver.1.1 This information is subject to change without prior notice. Disclaimer Asterisk, Inc.(Asterisk)

More information

COPYRIGHT 2009,SCSC. Manual P/No: SCCM - 80S-01A Released Date: Oct 31, 2009

COPYRIGHT 2009,SCSC. Manual P/No: SCCM - 80S-01A Released Date: Oct 31, 2009 To begin the configuration procedures Thank you for purchasing the scanner. Inside each packaging box, you may find the scanner, the interface cable and user's fuide. Configuration manual might be optional

More information

APPENDIX E COMMAND BARCODES

APPENDIX E COMMAND BARCODES APPENDIX E COMMAND BARCODES Scan command barcode(s) to quickly configure the CHS 7X or 7XRx. By default, the CHS is in HID mode as a Keyboard device. IMPORTANT! Make sure the CHS is not connected to a

More information

Operating Manual BCS-1 *

Operating Manual BCS-1 * Operating Manual BCS-1 * Barcode scanner Doc.Nr.:60000372 MANUAL BCS-1 NEX REV 0.0 EN 04.06.09 N.B. - 1 - List of Contents List of Contents...2 Introduction...3 BCS-1 * models available...4 Technical Data...5

More information

GS500 2D Area-Imaging Scanner. User Manual

GS500 2D Area-Imaging Scanner. User Manual GS500 2D Area-Imaging Scanner User Manual Table of Contents Table Of Contents... 1 Chapter 1 Getting Started... 6 About This Guide... 6 Barcode Scanning... 6 Barcode Programming... 6 Factory Defaults...

More information

LIMITATION OF LIABILITY

LIMITATION OF LIABILITY FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection

More information

Leitor Argox AS-9500 Imager

Leitor Argox AS-9500 Imager Leitor Argox AS-9500 Imager O novo Leitor de Código de Barras Manual Argox AS- 9500g Imager 2D é pequeno, leve, portátil e fácil de usar. Além de fazer a leitura de todos os tipos de código de barra, ele

More information

Wireless Pocket 2D Imager Scanner

Wireless Pocket 2D Imager Scanner Wireless Pocket 2D Imager Scanner - MS920P - User's Manual Version 1.0 2014 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co., Ltd. Table

More information

CONFIGURATION GUIDE ID-110

CONFIGURATION GUIDE ID-110 CONFIGURATION GUIDE ID-110 HSD 0320.011 / 09.17-V01de Table of content Bluetooth Settings 7 Bluetooth Radio Disconnect (Reconnect via Quick Connect Barcode) 7 () Bluetooth Auto Reconnect - Default 7 ()

More information

MS810 Laser Scanner. Product Reference Guide. Rev. A

MS810 Laser Scanner. Product Reference Guide. Rev. A MS810 Laser Scanner Product Reference Guide Rev. A 1 Preface About This Manual This manual explains how to install, operate and maintain the Unitech MS810 Laser Scanner. No part of this publication may

More information

MS810 Laser Scanner. Product Reference Guide. Rev. A

MS810 Laser Scanner. Product Reference Guide. Rev. A MS810 Laser Scanner Product Reference Guide Rev. A 1 Preface About This Manual This manual explains how to install, operate and maintain the Unitech MS810 Laser Scanner. No part of this publication may

More information

2DScan TM Barcode Scanner

2DScan TM Barcode Scanner 2DScan TM Barcode Scanner Quick Start Manual Default Check Version FCC WARNING STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part

More information

ES4200 Embedded Laser Barcode Scanner

ES4200 Embedded Laser Barcode Scanner ES4200 Embedded Laser Barcode Scanner User Manual Version: ES4200_UM_EN_V1.1.7 Notice Make sure you carefully read the following information to ensure that your barcode scanner is able to perform at the

More information

XB-8200 Hand Free Area Image Scanner Configuration Guide

XB-8200 Hand Free Area Image Scanner Configuration Guide XB-8200 Hand Free Area Image Scanner Configuration Guide V1.3 Table of Contents Chapter 1 General Description... 1 Chapter 2 Introduction... 2 Chapter 3 User Preferences... 4 RETURN TO DEFAULT... 4 PARAMETER

More information

1504/1504SE Barcode Scanner

1504/1504SE Barcode Scanner 1504/1504SE Barcode Scanner Setup barcodes included. Version 1.15 Copyright 2011~2014 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is

More information

WLP 4170 CCD Programming Guide

WLP 4170 CCD Programming Guide WLP 4170 CCD Programming Guide PROGRAMMING GUIDE Wasp WLP 4170 CCD Programming Guide Please Read Note: The Wasp WLP 4170 CCD Scanner is ready to scan the most popular bar codes out of the box. This manual

More information

This equipment has been tested and it complies with

This equipment has been tested and it complies with NOTICE: This equipment has been tested and it complies with This device complies with Part 15 of the FCC Rules. Operation shall be subject to the following two conditions: (1) This device may not cause

More information

ZB-8150/ZB-8110/ZB-8210 CCD BARCODE SCANNER. User s Manual. ZBA Inc 249 Homestead Rd Unit 12 Hillsborough NJ 08844

ZB-8150/ZB-8110/ZB-8210 CCD BARCODE SCANNER. User s Manual. ZBA Inc 249 Homestead Rd Unit 12 Hillsborough NJ 08844 ZB-8150/ZB-8110/ZB-8210 CCD BARCODE SCANNER User s Manual ZBA Inc 249 Homestead Rd Unit 12 Hillsborough NJ 08844 Phone: 908-359-2070 Fax: 908-359-1272 Web: http://www.zbausa.com/ Installation: Keyboard

More information

FD-011WU. 2D Barcode Reader User Guide V1.6CC

FD-011WU. 2D Barcode Reader User Guide V1.6CC FD-011WU 2D Barcode Reader User Guide V1.6CC Table of Contents 1 Getting Started... 1 1.1 Factory Defaults... 1 2 Communication Interfaces...2 2.1 TTL-232 Interface... 2 2.2 Baud Rate... 3 2.3 Data Bit

More information

1504 Barcode Scanner. Setup barcodes included. Version 1.11

1504 Barcode Scanner. Setup barcodes included. Version 1.11 1504 Barcode Scanner Setup barcodes included. Version 1.11 Copyright 2011~2013 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided

More information

1504/1504SE/1504A Barcode Scanner

1504/1504SE/1504A Barcode Scanner 1504/1504SE/1504A Barcode Scanner Setup barcodes included. Version 1.16 Copyright 2011~2016 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.;

More information

RT206 User Guide. RT206 OEM 2d Scan Engine User Guide

RT206 User Guide. RT206 OEM 2d Scan Engine User Guide RT206 OEM 2d Scan Engine User Guide Table Of Contents Chapter 1 Getting Started... 1 About This Guide... 1 Connecting EVK to PC... 1 Barcode Programming... 2 Factory Defaults... 2 Custom Defaults... 3

More information

Code Reader 4100 Configuration Guide

Code Reader 4100 Configuration Guide Code Reader 4100 Configuration Guide C006013_01_CR4100_ConfigurationGuide 1 Table of Contents Symbologies Aztec On - Default...5 (A1) Aztec Off...5 (A2) Aztec Inverse On...5 (A3) Aztec Inverse & Normal...5

More information

Model HP ElitePOS 2D Barcode Scanner (Black) HP ElitePOS 2D Barcode Scanner (White)

Model HP ElitePOS 2D Barcode Scanner (Black) HP ElitePOS 2D Barcode Scanner (White) Overview Model (Black) (White) 1RL97AA 3GS20AA Introduction Deliver an efficient customer experience with the breathtaking, HP s smallest, slimmest barcode scanner, designed to complement the HP ElitePOS.