1 Issue Datasheet EN Room controller pplication The is a room controller for stand-alone use or use in a LON network. For direct communication with other LON components, the is equipped with an integrated LON FTT10 interface. The room controller RCN155-L, RCN151-L can be expanded with operating modules. The room controller conforms to LON Works standard 2.0. This means that no additional costs are incurred for LON Works Credits during commissioning. Content Page Important Information Regarding Product Safety...2 Item...3 Technical Data...3 Compatibility...4 ccessories (not included in delivery)...5 Dimensions...5 Connection...6 Connection examples...7 ounting...10 Removal...11 Network Installation...12 Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications - Reservado el derecho a modificación - Wijzigingen voorbehouden - Con riserva di modifiche - Innehåll som skall ändras - Změny vyhrazeny - Zmiany zastrzeżone - Возможны изменения - változtatások jogát fenntartjuk - Kieback&Peter GmbH & Co. KG Tempelhofer Weg 50, Berlin/Germany Telefon: , Telefax: info@kieback-peter.com

2 Datasheet EN Issue Important Information Regarding Product Safety Safety Instructions This data sheet contains information on installing and commissioning the product "RCN155-L, RCN151-L". Each person who carries out work on this product must have read and understood this data sheet. If you have any questions that are not resolved by this data sheet, you can obtain further information from the supplier or manufacturer. If the product is not used in accordance with this data sheet, the protection provided will be impaired. pplicable regulations must be observed when installing and using the device. Within the EU, these include regulations regarding occupational safety and accident prevention as well as those from the VDE (ssociation for Electrical, Electronic & Information Technologies). If the device is used in other countries, it is the responsibility of the system installer or operator to comply with local regulations. ounting, installation and commissioning work on the devices may only be carried out by qualified technicians. Qualified technicians are persons who are familiar with the described product and who can assess given tasks and recognize possible dangers due to technical training, knowledge and experience as well as knowledge of the appropriate regulations. Legend WRNING Indicates a hazard of medium risk which can result in death or severe bodily injury if it is not avoided. CUTION Indicates a hazard of low risk which can result in minor or medium bodily injury if it is not avoided.! CUTION Indicates a hazard of medium risk which can result in material damage or malfunctions if it is not avoided. NOTE Indicates additional information that can simplify the work with the product for you. Notes on Disposal For disposal, the product is considered waste from electrical and electronic equipment (electronic waste) and must not be disposed of as household waste. Special treatment for specific components may be legally binding or ecologically sensible. The local and currently applicable legislation must be observed. Page 2 / 12

3 Issue Datasheet EN Item RCN155-L RCN151-L Room controller with 6 inputs and 11 outputs Room controller with 6 inputs and 8 outputs Technical Data Nominal voltage C 110 to 230 V ± 10 %; 50 Hz to 60 Hz; 18 V (consumption <1 W) Inputs Outputs starting current: 50 / C 230 V; 1 ms (I 2 t -value = s) 6 configurable inputs 2x KP10 or binary inputs P1, P2 2x NTC10K or binary inputs P3, P4 2x V or binary inputs P5, P6 2 BO: PW output or 3-point actuator; K1, K2 floating; C 24 V or C 230 V (Σ 400 m) 2x 1 W small thermoactuator C/DC 24 V; ST40405/80 or 4x 1 W small thermoactuator C 230 V; ST20405/80 1 BO: 1 binary output, floating relay contact K10; C 230 V (2 KW) / C 24 V, 10 3 BO: relay contact C 230 V, 3 ; K7, K8, K9 2 BO: relay contact C 230 V, 3 ; K5, K6 (not used with RCN151-L) 1 O: V; maximum 2.5 m; Y4 1 O: V; maximum 2.5 m; Y1 DC 24 V power supply (not used with RCN151-L) Σ 2 W 1 O: V; maximum 2.5 m; Y2 DC 24 V power supply Σ 2W NOTE s the thermo actuator PR42405 cannot be supplied with voltage via terminal assignments 23 and 26, an external power supply (configuration 8 W with 24 V per actuator) is needed. The RCN155-L does not support the PR Indicators and controls Green LED: Operation Red LED: LON status Push-button: LON Service Pin Interfaces LON FTT-10/FTT kbit/s plug-in screw terminal CN 4 poles for the connection with room modules RBW20x-C or RBW30x-C, screw terminals or RJ9 (20 m max.) power supply (internal) for DC 12 V room controllers Connection cross slot screw terminal, 2.5 mm 2 max. single-wired or multi-wired 0.34 mm 2 to 2.5 mm 2 WG Overvoltage category III Level of contamination 2 Page 3 / 12

4 Datasheet EN Issue Rated impulse withstand 4000 V voltage ode of operation Type 1 Housing Plastic; self-extinguishing according to UL94 V-0 Protection class This device is intended for installation in a wall-mounted enclosure or switch cabinet with protection class I or II. Degree of protection IP20 mbient temperature 0 C to 50 C mbient humidity During operation: 20 to 80 % relative humidity; non-condensing Out of operation: 5 to 90 % relative humidity; non-condensing Storage temperature -25 C to +55 C (class 1K3) Installation ounting rail TH Weight 0.3 kg Dimensions x 90 x 60 (WxHxD in mm) Certification eu.bac Cert rticle License No. pplication C-value (K) RCN151-L Fan Coil Unit Systems (4 pipes) (0 V to10 V) Fan Coil Unit Systems (2 pipes 2 wires) (0 V to 10 V) Fan Coil Unit Systems (4 pipes) (PW) Fan Coil Unit Systems (2 pipes 2 wires) (PW) RCN155-L Fan Coil Unit Systems (4 pipes) (0 V to 10 V) Fan Coil Unit Systems (2 pipes 2 wires) (0 V to 10 V) Fan Coil Unit Systems (4 pipes) (PW) Sensor types Type Value range and unit 0 to 10 V 0 to 100 % KP10-40 to 60 C NTC10K (NTC10K31) -40 to 60 C NTC10K (FCD; NTC103T-2,3) -40 to 60 C Resistor (potentiometer) 0 to 10 kω Compatibility Room controller RBW20x-C, RBW30x-C Fan Coil Unit Systems (2 pipes 2 wires) (PW) Page 4 / 12

5 Issue Datasheet EN ccessories (not included in delivery) Z178 Connection line: room control module and room controller (10 m) Z178/2 dapter: RJ9 plug - terminal block, 4-pole (15 cm) HW HW HW Z180 Solid state relay input voltage 18 to 36 V C/DC Solid state relay input voltage 90 to 280 V C Empty housing for wall mounting (8TE/IP30) Housing for wall mounting Installation space: one row, 324 mm (18 HP); 1 Dimensions 90,0 44,7 143,5 60,0 Page 5 / 12

6 Datasheet EN Issue Connection RCN155-L Y4 max. 0,4 K1 K2 10 K10 3 (2 ) K7 K8 K9 3 (2 ) K5 K6 N L Y1 Y2 +24V +24V P5 P6 P1 P2 P3 P KP10 NTC10K RCN151-L B LON +12V= C+ C CN RJ Y4 max. 0,4 K1 K2 10 K10 3 (2 ) K7 K8 K9 N L Y2 +24V P5 P6 P1 P2 P3 P KP10 NTC10K + B LON +12V= C+ C CN RJ Inputs P5, P6 I: V or BE: Binary (floating) P1, P2 I: KP10 or BE: Binary (floating) P3, P4 I: NTC10K or potentiometer 10 kω or BE: Binary (floating) Page 6 / 12

7 Issue Datasheet EN Outputs K1, K2 BO: Thermo actuator or 3-point actuator; max. C 230 V, 400 m K10 BO: Electric heating or light; max. C 230 V, 10, switch-on current max. 40 (corresponds to 2 typical conventional ballasts for fluorescent lamps) K7.. K9 BO: aximum 3-level fan; max. C 230 V, 3 K5, K6 BO: 3-point actuator; max. C 230 V, 3 (not used with RCN 151-L) Y4 O: 0 to 10 V, analog fan control; 2.5 m maximum Y1 O: V, valve or damper control; maximum 2.5 m; DC 24 V, 1 W power supply (not used with RCN151-L) Y2 O: V, valve or damper control; maximum 2.5 m; DC 24 V power supply Σ 2W Connection examples - Valve/fan C 230 V - Ventilation damper N L1 St Y4 K1 K2 K10 K7 K8 K9 K5 K Y1 +24V Y2 +24V P5 P6 P1 P2 P3 P KP10 NTC10K 0..1 B LON +12V= C+ C CN RJ Page 7 / 12

8 Datasheet EN Issue ! - connecting accessory CF071KD (RC element as additional suppressor circuit) CUTION Higher loads can occur at the relay output when switching fan motors, possibly resulting in high strain on the relays (observe the fan's data sheet!). When in doubt, a suppressing RC element is recommended per fan level to avoid malfunctions and damage to the room controller (accessory: CF071KD). N N L1 St x CF071KD L x Valve output as 3-point C 24 to 230 V - nalog fan 0..1 D15 D15 N N L Y4 K1 K2 K10 K7 K8 K9 K5 K Y1 Y2 +24V +24V P5 P6 P1 P2 P3 P KP10 NTC10K B LON +12V= C+ C CN RJ Page 8 / 12

9 Issue Datasheet EN - Sensor Y1 Y2 +24V +24V TDF14 KP Y1 Y2 +24V +24V 0,8W H% HTF12 KP10 10 NOTE connection of the potentiometer is only possible at the entrances P3 or P4, at terminals "33", "34" and "34", "35" and with the software version 1.60 or higher. Page 9 / 12

10 Datasheet EN Issue ounting WRNING Danger of death by electrocution. ount or remove only when power is switched off. TH Page 10 / 12

11 Issue Datasheet EN Removal WRNING Danger of death by electrocution. ount or remove only when power is switched off Page 11 / 12

12 Datasheet EN Issue Network Installation When commissioning a room controller in the "Lonaker Integration Tool", the unique Neuron ID of a real room controller is defined for a device in the drawing. You can find the Neuron ID in text form and as a barcode on the type plate and on the supplied configuration labels. You have the following options for entering the Neuron ID in the "Lonaker Integration Tool": anually: Enter the Neuron ID using the computer keyboard. Barcode: Scan the Neuron ID using a barcode scanner. Online: Receive the Neuron ID via the LON network. The computer with the network management tool must be connected to the LON network. The Neuron ID is transmitted when the service pin is entered on the room controller or when a magnet is used on a connected operator panel Service PIN 2 Service LED eanings of the "Service LED" (2) Red-green LED flashing: "Service PIN" (1) pressed Red LED flashing: Not commissioned Green LED: Commissioned Online installation on the room control module RBW20x-C or RBW30x-C: The technolon room controller can also be identified quickly and easily directly on the room control module using a magnet (3). magnet (3) is guided along the right side of room control module RBW20x-C or RBW30x-C. Internally, this triggers the service PIN in the RCN room controller. To verify this, a service LED (4) on the top part of the housing on the room control modules lights up green RBW205-C RBW305-C Page 12 / 12

RCN200-L Room Controller

RCN200-L Room Controller Issue 2014-10-30 Datasheet 2.80-30.200-01-EN Room Controller pplication The is a LON bus-capable room controller for energy-efficient temperature, air quality and humidity control. It can be used with

More information

RCN122-L technolon Room Controller. Application. RCN122-L technolon Room Controller. Product Description

RCN122-L technolon Room Controller. Application. RCN122-L technolon Room Controller. Product Description Issue 2014-10-20 Datasheet 2.80-10.222-01-EN pplication The is a bus-communicating room controller for fan convectors, with heating and cooling coils and blind control for fan coil applications. It communicates

More information

RCN132-L, RCN132-L-S1 technolon Room Controller

RCN132-L, RCN132-L-S1 technolon Room Controller Issue 2014-10-21 Datasheet 2.80-10.232-01-EN technolon Room Controller pplication The is a bus-communicating room controller for VV (variable-air-volume) damper control with heating and cooling coils and

More information

TD11..15, TDF Room Temperature Sensors

TD11..15, TDF Room Temperature Sensors Issue 2011-08-30 Datasheet 1.10-10.010-01-EN Room Temperature Sensors pplication TD11..15 and TDF12..15 are used to measure the room temperature. The temperature sensors are used in conjunction with all

More information

HT12, HTF12 Room humidity/temperature sensor

HT12, HTF12 Room humidity/temperature sensor Issue 2016-11-09 Datasheet 1.40-20.012-01-EN Room humidity/temperature sensor pplication The HT12 and HTF12 are used for continuous measurement the relative humidity and room temperature in homes and offices.

More information

RCC200-L Room Controller

RCC200-L Room Controller Issue 2014-04-14 Datasheet 2.80-20.200-01-E Room Controller pplication The is a O bus-capable room controller for energy-efficient temperature, air quality and humidity control. It can be used with onmark-compliant

More information

TLD1..TLD4 Duct Temperature Sensors

TLD1..TLD4 Duct Temperature Sensors Issue 2015-07-08 Datasheet 1.10-11.010-01-EN Duct Temperature Sensors pplication The sensors are used as controlled variable sensors for duct installation in all outside-temperature controlled or fixed-value

More information

RCN420-B Room controller

RCN420-B Room controller Issue 2017-07-20 Datasheet 2.80-30.420-01-EN Room controller pplication The is a Cnet-capable room controller for energy-efficient temperature, air quality and humidity control. It can be used with customer-specific

More information

BMD4032 Input/output module

BMD4032 Input/output module Issue 2015-08-21 Datasheet 2.60-70.02-01-EN Input/output module pplication The input/output module with 2 digital inputs or outputs receives System 000 binary signals and activates binary control functions.

More information

FBM034 and FBM034W Fieldbus Input Modules

FBM034 and FBM034W Fieldbus Input Modules Issue 2014-10-01 Datasheet 2.50-30.034-31-EN FBM034 and FBM034W Fieldbus Input Modules pplication With four analog inputs, fieldbus input modules FBM034 und FBM034W record the signals of remote devices

More information

SBM52/04 Input / Output Module For M-Bus with 99 counters

SBM52/04 Input / Output Module For M-Bus with 99 counters Issue 2014-11-19 Datasheet 2.50-40.052-31-EN Input / Output Module For M-Bus with 99 counters pplication The is used to connect a maximum of 99 meters for external equipment to DDC controller DDC3000/DDC4000

More information

FBU410 Input/ Output Modulel

FBU410 Input/ Output Modulel Issue 2016-10-12 Datasheet 2.50-30.410-01-EN Input/ Output Modulel pplication The Ein-usgabe-Modul with 4 relay outputs and 6 universal inputs/outputs controls and records the signals of remote devices

More information

NOTE Hinweis: Note the special features of firmware updates provided by EPROM-Tausch (see page 4).

NOTE Hinweis: Note the special features of firmware updates provided by EPROM-Tausch (see page 4). Issue 2014-11-19 Datasheet 2.50-40.051-31-EN Switch cabinet bus module with M-Bus input for 32 counters pplication The switch cabinet bus module is used to connect a maximum of 32 counters for external

More information

RBW301-C, RBW302-C, RBW304-C, RBW305-C Room Control Module

RBW301-C, RBW302-C, RBW304-C, RBW305-C Room Control Module Issue 2011-04-01 Datasheet 1.10-60.010-01-EN Room Control Module pplication are room control modules with displays for connecting to RCC200-L or RCN200-L room controllers. Different variants with a graded

More information

TPC35 Display and operator panel

TPC35 Display and operator panel Issue 2014-08-06 Datasheet 2.70-10-435-01-EN Display and operator panel pplication The is a remote display and operator panel for BMR410 and DDC420. It has an active matrix color LCD touchscreen with a

More information

FBS51/04 Gateway-Module For M-Bus with 6 counters

FBS51/04 Gateway-Module For M-Bus with 6 counters Issue 2014-11-26 Datasheet 2.50-40.151-01-EN Gateway-Module For M-Bus with 6 counters pplication The Gateway Module is used to connect a maximum of 6 meters of external equipment to the BMR or DDC420 via

More information

TPC84 Display and Operator Panel

TPC84 Display and Operator Panel Issue 2014-08-06 Datasheet 2.60-10.084-01-EN Display and Operator Panel pplication The is a remote display and operator panel. It has an active matrix color LCD touchscreen with a screen size of 21,3 cm

More information

FBM018 and FBM018W Fieldbus Input Modules

FBM018 and FBM018W Fieldbus Input Modules Issue 2014-05-27 FBM018 and FBM018W Fieldbus Input Modules pplication With 8 digital inputs, the FBM018 und FBM018W Eingabe-Modul Feldbus record the signals from remote devices in DDC3000 and DDC4000/BMR

More information

Important Information Regarding Product Safety...2 Item...3 Technical Data...3 Dimensions...4 Connection...4 Mounting...5 Maintenance...

Important Information Regarding Product Safety...2 Item...3 Technical Data...3 Dimensions...4 Connection...4 Mounting...5 Maintenance... Issue 2013-10-24 Datasheet 1.40-21.450-01-EN Room Humidity/Temperature Sensor pplication The room humidity/temperature sensor with an integrated measurement converter is used for measuring the relative

More information

IT554 VPN Router IT554. Product Description

IT554 VPN Router IT554. Product Description Issue 2011-11-08 Datasheet 4.30-50.554-01-EN VPN Router pplication is a VPN router with client functionality and customized software that enables the secure transfer of encrypted data between controllers

More information

SBM51/04 Switch cabinet bus module For M-Bus with 32 counters

SBM51/04 Switch cabinet bus module For M-Bus with 32 counters Issue 2012-08-28 Datasheet 2.50-40.051-31-EN Switch cabinet bus module For M-Bus with 32 counters pplication The switch cabinet bus module is used to connect a maximum of 32 counters for external equipment

More information

DDC110S Room Control Modul With LCD Display

DDC110S Room Control Modul With LCD Display Issue 2012-01-26 Datasheet 1.10-31.110-01-EN Room Control Modul With LCD Display nwendung The bus-capable room control module with LCD display is used as part of the DDC3000 and DDC4000/BMR automation

More information

TPC56 Display and operator panel

TPC56 Display and operator panel Issue 2013-06-26 Datasheet 2.70-10-456-01-EN Display and operator panel pplication The is a remote display and operator panel for BMR410 and DDC420. It has an active matrix color LCD touchscreen with a

More information

BCU070-L technolon Switch Interface. Application. BCU070-L technolon Switch Interface. Product description

BCU070-L technolon Switch Interface. Application. BCU070-L technolon Switch Interface. Product description Issue 2007-10-01 Datasheet 2.80-50.070-01-EN pplication The technolon switch interface binary controller for flush mounting, 7 BI / 2 BO. Bus-capable switch interface with open communication using the

More information

GLT-M002-GLTM GLT-M002-GLTM. Product Description

GLT-M002-GLTM GLT-M002-GLTM. Product Description Issue 2011-07-19 Datasheet 4.70-10.013-01-EN pplication The GSM modem connects the building management system to the DDC system of the operational plant via the cellular network. The DDC system can then

More information

Important Information Regarding Product Safety...2 Item...3 Technical Data...3 Installation Dimensions...4 Mounting...5 Connection...

Important Information Regarding Product Safety...2 Item...3 Technical Data...3 Installation Dimensions...4 Mounting...5 Connection... Issue 20160127 Datasheet 2.5010.20001EN Controller pplication The is a central control unit for closedloop and openloop control, optimizations and monitoring functions. The controller meets the following

More information

TPC70Display and Operator Panel

TPC70Display and Operator Panel Issue 2017-09-13 Datasheet 2.60-10.070-01-EN Display and Operator Panel pplication The is a remote display and operator panel. It has a color TFT touchscreen with a screen size of 7 / 17,8 cm. The can

More information

DDC420 Automation Station

DDC420 Automation Station Issue 2016-09-26 Datasheet 2.70-10.420-01-EN utomation Station pplication is a controller for closed-loop and open-loop control, monitoring and optimizing heating, ventilation and air conditioning systems.

More information

GLT-D004-TFA4 Color Ink Jet Printer A4

GLT-D004-TFA4 Color Ink Jet Printer A4 Issue 2012-08-13 Datasheet 4.65-20.004-11-EN Color Ink Jet Printer 4 pplication You can use the printer described in this document to print documents (for example plant schematics and trend curves) from

More information

RCW11x-L Room Controller Technolon. Application. Product Description. RCW11x-L Room Controller Technolon

RCW11x-L Room Controller Technolon. Application. Product Description. RCW11x-L Room Controller Technolon Issue 2008-04-03 Datasheet 2.80-20.100-01-EN pplication The technolon room controllers RCW112-L, RCW113-L, RCW115-L, RCW116-L enable you to control the temperature of individual rooms by means of radiator,

More information

BMR410 Controller BMR410. Product Description

BMR410 Controller BMR410. Product Description Issue 2011-04-27 Datasheet 2.70-10.411-01-EN Controller pplication The is a DDC controller for regulating, controlling, monitoring and optimizing heating, ventilation and air conditioning systems. The

More information

IT560 VPN router IT560. Commissioning

IT560 VPN router IT560. Commissioning Issue 2018-02-22 Datasheet 4.30-50.560-11-EN VPN router pplication is a VPN router with server functionality and customized software that enables the secure transfer of encrypted data between controllers

More information

Commissioning. IT554 VPN Router

Commissioning. IT554 VPN Router Issue 2012-01-23 Datasheet 4.30-50.554-11-EN VPN Router pplication is a VPN router with client functionality and customized software that enables the secure transfer of encrypted data between controllers

More information

DDC4200e Automation Station with Operator Function

DDC4200e Automation Station with Operator Function Issue 2014-07-08 Datasheet 2.60-10-210-01-EN utomation Station with Operator Function pplication Color touchscreen with BCnet communication Standalone station with operator function for closed-loop and

More information

DDC4200e Controller with Operator Function

DDC4200e Controller with Operator Function Issue 2017-04-13 Datasheet 2.60-10-210-01-EN Controller with Operator Function pplication Color touchscreen with BCnet communication Standalone station with operator function for closed-loop and open-loop

More information

Note: Note the changed parameter functions due to firmware updates (see page 5).

Note: Note the changed parameter functions due to firmware updates (see page 5). Gateway Module for Danfoss Frequency Inverters pplication With the gateway module, you can connect up to eight Danfoss frequency inverters (FIs) of various types using the Danfoss bus with the DDC3000/DDC4000

More information

SBM51/05 gateway module for Berg network monitoring

SBM51/05 gateway module for Berg network monitoring Issue 2016-09-08 Datasheet 2.50-40.051-52-EN gateway module for Berg network monitoring pplication The gateway module with an RS485 connection is used to connect up to 8 Berg network monitoring components

More information

BMF400 Input/output module

BMF400 Input/output module BMF400 Input/output module Input/output module with six universal inputs/outputs and four floating relay outputs for function extensions of the BMR bus module controller. Issue date: December 6, 2006 Subject

More information

RBU130-RJ/sw, RBU130-RJ/ws Room Controllers

RBU130-RJ/sw, RBU130-RJ/ws Room Controllers Issue 2016-08-02 Datasheet 2.80-30.130-01-EN Room Controllers pplication The RBU130-RJ/sw and RBU130-RJ/ws room controller provide precise comfort zone control for temperature, fan speed, lighting and

More information

Actuating drive with spring return DSFY/16 Modulated actuating drive with spring return

Actuating drive with spring return DSFY/16 Modulated actuating drive with spring return ctuating drive with spring return DSFY/16 Modulated actuating drive with spring return Issue date: Feb. 27, 2006 Subject to change Contents Page Information about the device description... 2 Qualified

More information

GLT2200N BMS Network Operator Station

GLT2200N BMS Network Operator Station Issue 2011-10-21 Datasheet 4.10-20.200-36-EN BMS Network Operator Station pplication BMS network operator station for higher-level building management functions and for connecting controllers. Content

More information

ROUTER-2SHDSL-RAIL-001/01

ROUTER-2SHDSL-RAIL-001/01 Issue 2017-04-19 User Information Datasheet 4.30-50.027-85-EN ROUTER-2SHDSL-RAIL-001/01 ROUTER-2SHDSL-RAIL-001/01 Application The ROUTER-2SHDSL-RAIL-001/01 contains two SHDSL drivers and a four-port switch.

More information

Neutrino-GLT Server BACnet TM Protocol Implementation Conformance Statement (PICS) Version 3

Neutrino-GLT Server BACnet TM Protocol Implementation Conformance Statement (PICS) Version 3 Issue date: 2005-05-01 data sheet 4.10-10.701-03-en BCnet TM Protocol Implementation Conformance Statement () Version 3 Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications

More information

DDC4200 BACnet TM Protocol Implementation Conformance Statement (PICS) Version 1

DDC4200 BACnet TM Protocol Implementation Conformance Statement (PICS) Version 1 Issue date: 2008-05-12 data sheet 2.60-10.200-03-en DDC4200 BCnet TM Protocol Implementation Conformance Statement () Version 1 Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications

More information

DDC110-L1.. DDC110-L4 technolon Room Module

DDC110-L1.. DDC110-L4 technolon Room Module technolon Room Module DDC110-L1, DDC110-L2, DDC110-L3 and DDC110-L4 Single room control or room display and service module for single-room control in the LON network. With display of the room temperature

More information

Wireless Small Actuator MAC-WSA

Wireless Small Actuator MAC-WSA Wireless Small Actuator MAC-WSA MAC-WSA Wireless Small Actuator Application Wirelessly controlled, battery-powered small actuator for continuous closed-loop control systems. For thermostat valve bodies

More information

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications 3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications s 3 856 Desigo RXC Room controller RXC39.5 Communicating room controller for fan-coil applications The RXC39.5 room controller is used for temperature control in individual rooms. For fan-coil systems

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13 s 3 875 RXB Room controller Communicating room controller for fan-coil applications FC-13 RXB39.1 The RXB39.1 room controller is used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012 Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982201 The push button interface UP 220/31 is a binary input and output devices for installation

More information

Analog display for resistance current

Analog display for resistance current www.reinhausen.com Analog display for resistance current Operating Instructions BA 2220061/01 NOTE The product may have been modified after this document went to press. We expressly reserve the right to

More information

Non-communicating room controllers

Non-communicating room controllers 3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,

More information

Neutrino-GLT Client BACnet TM Protocol Implementation Conformance Statement (PICS) Version 4

Neutrino-GLT Client BACnet TM Protocol Implementation Conformance Statement (PICS) Version 4 Issue date: 20050501 data sheet 4.1010.70104en BCnet TM Protocol Implementation Conformance Statement () Version 4 Änderungen vorbehalten Contents subject to change Sous réserve de modifications Reservado

More information

Extension module for lighting control

Extension module for lighting control s 3 842 DESIGO RXC Extension module for lighting control Extension to the RXC30 / RXC31 / RXC38 room controller RXC40.1 RXC40.5 The RXC40 extension module is used in conjunction with an RXC30, RXC31 or

More information

Push Button Interface UP 220D31

Push Button Interface UP 220D31 Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982203 The push button interface is a binary input and output devices for installation in in-wall

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft echnical data sheet LH24A-MF2-P Parmeterisable linear actuator for adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 5 N Nominal voltage

More information

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s SRQ24A Rotary actuator for ball valves orque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s echnical data Electrical data Nominal voltage AC 24V, 50/60Hz / DC 24V Nominal voltage range

More information

TAC Xenta 121-FC Programmable Fan Coil Application

TAC Xenta 121-FC Programmable Fan Coil Application TAC Vista TAC Xenta 121-FC Programmable Fan Coil Application TAC Xenta 121-FC is an easily programmable controller intended for both 2-pipe and 4-pipe applications, with or without re-heat. It can be configured

More information

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX HCC/S Heating/cooling circuit controller ABB i-bus KNX HCC/S 2.2.1.1 Heating/cooling circuit controller Description of product The device is a modular DIN rail component (MDRC) in pro M design. It is intended for installation in distribution

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B 3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

Compact Universal Controllers

Compact Universal Controllers 7 865 ISO9001 RWF40... complete with housing Compact Universal Controllers RWF40... The RWF40... is a universal digital boiler temperature / pressure controller with functions designed specifically for

More information

Non-communicating room controllers

Non-communicating room controllers 3 881 DESIO RXA on-communicating room controllers For fan-coil systems RXA20.1 RXA21.1 RXA22.1 The RXA20.1, RXA21.1 and RXA22.1 room controllers are used for temperature control in individual rooms. For

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LR24A-MOD Communicative rotary actuator for ball valves orque motor 5 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet

More information

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B 3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled

More information

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3 Operating Instructions Control Unit SGRST 153 Version 0.3 1004931 SGRST 153 Original instructions GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY Tel.: +49 731 20610 Fax: +49 731 2061222 EMail: info.ulm@mayser.com

More information

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011 , 2CDG 110 15x R0011 SA/S 12.6.1.1 2CDC 071 033 S0012 The 6 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are suitable for

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

Universal Controller

Universal Controller 3 342 Universal Controller For comfort control in HVAC & R-Systems Standalone electronic universal controller with P or PI response Operating voltage in accordance to type AC 24 V Control application selectable

More information

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in prom design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12 3 877 3877P0 RXL Room controllers Communicating controllers for fan-coil applications FC-0, FC-, FC2 RXL2. RXL22. The RXL2. and RXL22. room controllers are used for temperature control in individual rooms.

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

Electronic Temperature Controller. Instruction Manual Version

Electronic Temperature Controller. Instruction Manual Version Electronic Temperature Controller 701 Instruction Manual Version 1.00.01 Dear Customer, we have made up this operating manual in such a way that all necessary information about the product can be found

More information

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets.

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets. 40 Series - Miniature PCB/Plug-in relays 8-10 - 12-16 40 1 & 2 Pole relay range 40.31-1 Pole 10 (3.5 mm pin pitch) 40.51-1 Pole 10 (5 mm pin pitch) 40.52-2 Pole 8 (5 mm pin pitch) PCB mount - direct or

More information

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

English. Operating manual. Limit switch GS125.  Keep for future reference. Ventures / brands of GHM English Operating manual Limit switch GS125 Ventures / brands of GHM www.ghm-messtechnik.de Keep for future reference. Table of contents Page 1. Intended use (areas of application)... 3 1.1 Safety signs

More information

Heating Circuit Controller

Heating Circuit Controller 2 706 Synco living Heating Circuit Controller RRV918 RF-controlled heating circuit controller for up to 8 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility

More information

EYE 200: DDC single-room controller, ecos200

EYE 200: DDC single-room controller, ecos200 Product data sheet 94.200 EYE 200: DDC single-room controller, ecos200 How energy efficiency is improved Individual unitary control, fan coil units, chilled-beam control system, etc. Features Part of the

More information

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

English. Operating Manual. Conductive point level switch MLR120.  Retain for later reference. Companies / brands of GHM English Operating Manual Conductive point level switch MLR120 Companies / brands of GHM www.ghm-group.de Retain for later reference Table of contents Page 1. Proper use (application areas)... 3 Safety

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

Room Temperature Controllers

Room Temperature Controllers 3 021 Room Temperature Controllers for two-pipe fan coil units RCC10 Output for on / off valve actuator Outputs for three-speed fan Control depending on the room or return air temperature (RCC10) Automatic

More information

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions , Equipment protection fuse with Ex mb II C Gb approval Geräteschutzsicherung mit Zulassung Ex mb II C Gb Fusible de protection d appareil avec homologation Ex mb II C Gb Example / Beispiel / Exemple:

More information

Room unit with PPS2 interface

Room unit with PPS2 interface 1 642 Desigo RX Room unit with PPS2 interface for use with: QAX33.1 devices of the ranges Desigo RXC, RXB, RXL, and RXA (PPS2) Desigo PX Automation stations 1) devices with a PPS2 interface Room temperature

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Contents Notice about the device description...page 2. Device description

Contents Notice about the device description...page 2. Device description FBM6U Field Bus Modul with 4 Relay outputs and 4 digital inputs as well as a connection to a FSM0//4/6 FieldBusModule FBM6U with four relay outputs and four digital inputs as well as connection of a FrontSwitchingModule

More information

Heating Circuit Controller

Heating Circuit Controller 2 705 Synco 900 Heating Circuit Controller RRV912 RF-controlled heating circuit controller for up to 2 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility

More information

Miniature PCB Relays A

Miniature PCB Relays A SЕRIES Miniature PCB Relays 8-10 - 12-16 Medical and dentistry Control panels Panels for electrical distribution Toys utomation for blinds, grilles and shutters Door and gate openers Electronic circuit

More information

Access Terminal IF-800

Access Terminal IF-800 95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information