1 Issue Datasheet EN Room Controllers pplication The RBU130-RJ/sw and RBU130-RJ/ws room controller provide precise comfort zone control for temperature, fan speed, lighting and sunblinds with the following controller applications: Fan coil units Heated and chilled ceilings Radiator heating Lighting and sunblind applications The RBU130-RJ/sw and RBU130-RJ/ws room controller can be used as a classic wall-mounted room device (flush-mounting). Content Page Important Information Regarding Product Safety...2 Overview...3 Features & Benefits...3 Item...4 Technical Data...4 ccessories (not included in delivery)...5 Dimensions...6 Mounting...7 Removal...7 Home Screen...8 Main Menus...10 RBU130-RJ/xx Displaying and Hiding Menus...10 Fan Speed...10 Lighting...11 Sunblinds...12 Setpoint...13 Scenes...14 Scene Configuration Menu...14 Scene ctivation...14 Scene Deactivation...16 RBU130-RJ/xx Configuration - Installation Mode...17 RBU130-RJ/xx dvanced Technician Mode...18 Registry Management...18 Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications - Reservado el derecho a modificación - Wijzigingen voorbehouden - Con riserva di modifiche - Innehåll som skall ändras - Změny vyhrazeny - Zmiany zastrzeżone - Возможны изменения - változtatások jogát fenntartjuk - Kieback&Peter GmbH & Co. KG Tempelhofer Weg 50, Berlin/Germany Telefon: , Telefax:
2 Datasheet EN Issue Important Information Regarding Product Safety Safety Instructions This data sheet contains information on installing and commissioning the product "RBU130-RJ/sw, RBU130-RJ/ws". Each person who carries out work on this product must have read and understood this data sheet. If you have any questions that are not resolved by this data sheet, you can obtain further information from the supplier or manufacturer. If the product is not used in accordance with this data sheet, the protection provided will be impaired. pplicable regulations must be observed when installing and using the device. Within the EU, these include regulations regarding occupational safety and accident prevention as well as those from the VDE (ssociation for Electrical, Electronic & Information Technologies). If the device is used in other countries, it is the responsibility of the system installer or operator to comply with local regulations. Mounting, installation and commissioning work on the devices may only be carried out by qualified technicians. Qualified technicians are persons who are familiar with the described product and who can assess given tasks and recognize possible dangers due to technical training, knowledge and experience as well as knowledge of the appropriate regulations. Legend WRNING Indicates a hazard of medium risk which can result in death or severe bodily injury if it is not avoided. CUTION Indicates a hazard of low risk which can result in minor or medium bodily injury if it is not avoided.! CUTION Indicates a hazard of medium risk which can result in material damage or malfunctions if it is not avoided. NOTE Indicates additional information that can simplify the work with the product for you. Notes on Disposal For disposal, the product is considered waste from electrical and electronic equipment (electronic waste) and must not be disposed of as household waste. Special treatment for specific components may be legally binding or ecologically sensible. The local and currently applicable legislation must be observed. Page 2 / 20
3 Issue Datasheet EN Overview Thanks to its user-friendly interface, the RBU130-RJ/sw and RBU130-RJ/ws room controller present an optimized ergonomics for an immediate control of each room comfort parameter (lighting, temperature, sunblinds and fan speed) and instant access to 1 of the 4 saved scenes. These 4 different scenes drive all the working conditions of the room and can be easily programmed to recall specific settings depending on the dedicated use. The room controllers are customizable to fit any interior design. Their wide range of front plates allows you to choose between 12 different styles. The automation of the backlight intensity, regulated by its embedded sensor depending on the room ambient luminosity, improves the reading comfort while adding to its discretion. Moreover, the ECO-Vue icon illustrates the impact of the user's settings on the global energy efficiency of the building so as to lead him to follow the supervisor's recommendations. It displays more leaves for environmentally friendly settings so as to help reducing operating costs. password protected technician mode allows the integrator to perform commissioning, basic settings and troubleshooting. The RBU130-RJ/sw and RBU130-RJ/ws room controller are designed to interface with the room controller models of the RCC1xx-L series. The connection is made through a plug and play RJ9 cable. The room controllers can also be used in connection with the LCC1xx-L and SCC1xx-L lighting and sunblind series. Features & Benefits Full color LCD display for real-time control of room settings. Combined with its touch sensitive screen and its user-friendly interface, the room controller allow any occupant to manage easily HVC, lighting and sunblind parameters. Up to 4 scenes stored for instant access to favorite comfort parameters. 12 different front sides and customizable pictograms to fit any project and suit architects and building owners' aesthetic needs. ECO-Vue icon to indicate graphically energy efficiency of the configuration to help the occupant adopt energy conscious behavior and therefore save energy costs. utomatic backlight dimming depending on the ambient lighting level in room driven by an embedded sensor. Occupancy control to extend normal system operating hours for further time flexibility. ccess to controller's key features with a suitable interface to ease the integrator's job. single plug and play cable to connect both power and communication for easy installation and system retrofit at reduced costs (RJ9 connection). Page 3 / 20
4 Datasheet EN Issue Item RBU130-RJ/sw brushed aluminum style, black RBU130-RJ/ws brushed aluminum style, white Econ-Vue Icon The ECO-Vue icon is to encourage the users to follow the supervisor's recommendations and therefore promote thermal homogeneity in the building so as to reduce the associated operating costs. By displaying the maximum of leaves for close to setpoint manual settings, the ECO-Vue icon illustrates act on its energy efficiency. It illustrates the favorable or unfavorable character of the user's choices on the energy-efficiency of the building. Low energy efficiency Medium energy efficiency High energy efficiency Maximum energy efficiency Technical Data RBU130-RJ/xx Room Controller with Graphic Display Nominal voltage 5 V DC +/-0.1 V DC, supplied by a controller Power consumption 250 mw Interfaces RJ9 cable; voltage supplied by room controller Display Full color TFT display with backlight Controls resistive touchscreen Measuring element 10 kω NTC thermistor Measuring range 5 C to 36.9 C mbient temperature 5 to +40 C mbient humidity during 0 to 95 % r.h. non-condensing operation Mounting wall mounting Weight 0.2-kg Dimensions W x H x D 85,3 x 120,3 x 18,0-mm Page 4 / 20
5 Issue Datasheet EN ccessories (not included in delivery) Configurable Room Controllers RCC107-L RCC108-L RCC117-L RCC118-L SCC124-L SCC124-L/24 SCC128-L SCC128-L/24 Powered terminal unit (24 or 230 V C valves); 12 or 14-point configurable controller. 4 and 8 channel sunblind controllers for 24 V DC and 230 V C sunblind motors. LCC164-L LCC168-L LCC174-L LCC178-L 4 and 8 channel lighting controllers for dimming and switching. Wiring for ccessories Z178-CIT Connection line between room control module and room controller (RJ9 plug on both sides; 1,5 m) Z178 Connection line between room control module and room controller (RJ9 plug on both sides; 10 m) Z178-15M Connection line between room control module and room controller (RJ9 plug on both sides; 15 m) Z178/2 dapter RJ9 plug - terminal block 4 pole for the connection to a 2 x 2 x 0.8 YST cable Optional front plates The front plates system makes the style of the RBU130-RJ/sw and RBU130-RJ/ws room controllers fully customizable. You can either create your own ones or you can select the design that will fit the final environment and choose between the 12 optional front plates: Page 5 / 20
6 Datasheet EN Issue Color Product Reference Description Material Smart-Sense-FS-DB a luminium front-side luminium Smart-Sense-FS-B b Black front-side BS V0 Smart-Sense-FS-GLW Glossy light wood front-side BS V0 Smart-Sense-FS-DW Glossy dark wood front-side BS V0 Smart-Sense-FS-MF Mirror finish front-side BS V0 Smart-Sense-FS-GEB Glossy green front-side BS V0 Smart-Sense-FS-R Red front-side BS V0 Smart-Sense-FS-WW White wood front-side BS V0 Smart-Sense-FS-GW c Glossy white front-side BS V0 Smart-Sense-FS-GG Glossy grey front-side BS V0 Smart-Sense-FS-GMF Golden mirror finish front-side BS V0 Smart-Sense-FS-GSB Glossy navy blue front-side BS V0 a. included in the delivery b. included in the delivery of model RBU130-RJ/sw c. included in delivery of model RBU130-RJ/ws Dimensions 85,3 13,5 120,3 18,0 Page 6 / 20
7 Issue Datasheet EN Mounting! CUTION Only qualified technicians may install or remove the device. Wall mounting Z Removal Page 7 / 20
8 Datasheet EN Issue Home Screen The RBU130-RJ/xx home screen consists of several icons to clearly display information and to allow easy access to the different menus and options. ll menus are accessed by tapping the corresponding icon on the RBU130-RJ/xx sensor screen bb. 1: The RBU130-RJ/xx sensor home screen Item Description 1 Company logo 2 Occupancy controls 3 mbient temperature display 4 Numbered star keys (1 to 4) to select predefined scenes 5 Temperature setpoint display and access to the setpoint menu 6. Sunblind menu Page 8 / 20
9 Issue Datasheet EN Item Description 7. Lighting menu 8. Fan speed status display and access to the fan speed menu 9. ECO-Vue leaf pattern displays energy consumption for the current settings The colored icons represent enabled or active functions while the grayed out icons illustrate disabled or inactive functions as shown hereunder: Colored icon: enabled or active function Grayed out icon: disabled or inactive icon To return to the home screen from a selected menu, tap again the corresponding menu icon. Page 9 / 20
10 Datasheet EN Issue Main Menus This section explains the RBU130-RJ/xx main menus: Fan Speed, lighting, sunblinds, and temperature setpoint. RBU130-RJ/xx Displaying and Hiding Menus The integrator can choose to hide any menu which is not needed (Occupancy Fan speed Lighting Blinds Temperature) in proceeding as follows: Keep the matching pictogram pressed until the password screen becomes visible. Enter the password (9995). The pictogram disappears and the end user can no longer enter the matching menu. llowing access to a hidden menu follows the same procedure: Keep the empty position of the menu pictogram pressed until the password screen becomes visible. Enter the password (9995). The pictogram reappears. Fan Speed The fan speed menu is used to control the fan speed settings. In order to change the fan speed settings, proceed as follows: Tap the fan speed icon. The fan speed menu is displayed: Fan off 2 Fan speed 1 3 Fan speed 2 4 Fan speed 3 5 Fan uto 6 Current fan setting Set the fan to the desired speed: Off, 1, 2, or 3 or to the automatic setting (uto) which adjusts the fan speed according to the gap between ambient and desired temperature. Return to the home Screen by tapping the icon of the fan speed menu. The selected settings are saved until the next modification. 5 Page 10 / 20
11 Issue Datasheet EN Lighting The lighting menu is used to control the lights (on/off, dimming) and the available lighting groups (up to 8 groups). Tap the lighting icon. The lighting menu is displayed: Lighting groups Light up 3 Light down 4 Scrolling arrow to access the other lighting groups Tap the icon(s) of the lighting group(s) that you wish to set. You can select as many groups as you want simultaneously. Selected light groups are shown colored while inactive ones are grayed out. Tap the light up/down arrows to switch the lights on or off. If you are using a dimmer, tap and hold the light up/down arrows to gradually increase/decrease the luminosity. Tap again the light up/down arrows to stop the dimming action when it has reached the desired luminosity; if not, the dimming action will continue until maximum lighting or until completely turned off. fter a few seconds, the home screen is displayed. The selected settings are saved until the next modification. Page 11 / 20
12 Datasheet EN Issue Sunblinds The sunblinds menu allows you to separately adjust the height of each group of sunblinds (up to 8 groups depending on the configuration) and control the rotation of the sunblind strips. Tap the Sunblind icon. The sunblinds menu is displayed: Scrolling arrow to access the other groups 2 Blinds up 3 Blinds rotation 4 Blinds down 5 Blinds groups 1..8 Tap the icon(s) of the sunblind group(s) that you wish to set. You can select as many groups as you want simultaneously. Selected sunblind groups are shown colored while inactive ones are grayed out. Tap the sunblind up/down arrows to bring up or down the selected sunblind. Tap the arrows again to stop the action otherwise it will stop only once the sunblind is completely up or down. Tap the rotation arrow to rotate the sunblind strips. Holding down the rotation icon will make the sunblind strips gradually rotate until you release the icon. If you do it again, then the strips will rotate backwards. Return to the home screen by tapping the icon of the sunblind menu. The selected settings are saved until the next modification. Page 12 / 20
13 Issue Datasheet EN Setpoint The setpoint menu is used to adjust the temperature setpoint. In order to change the setpoint, proceed as follows: Tap the setpoint icon. The setpoint menu is displayed: Setpoint up 2 Setpoint down 3 Current temperature setpoint Tap the setpoint up/down arrows to increase or decrease the current temperature (+/- 6 from the predefined setpoint). Return to the home screen.by tapping on the icon of the setpoint menu. The selected settings are saved until the next modification. NOTE The midpoint corresponds to the temperature setpoint defined by the building manager. Page 13 / 20
14 Datasheet EN Issue Scenes The RBU130-RJ/xx room sensor can store up to four different scenes that are used to easily recall predefined comfort parameter settings. Parameters controlled by the scene appear colored while the others are grayed out. scene can control all of the following comfort parameters: Occupancy Fan speed Lighting Sunblinds Setpoint Scene Configuration Menu Scene ctivation To activate the scene menu, tap the scene icon that corresponds to the scene of your choice. The following screen temporarily appears to show that the selected scene has been triggered: NOTE If a scene is deactivated, the corresponding scene icon will not appear. Nevertheless, you can still enter the scene menu by pressing the icon s usual position. To enter the scene menu, proceed as follows: Tap and hold the scene icon that corresponds to the scene of your choice until the corresponding scene menu appears. Page 14 / 20
15 Issue Datasheet EN Selected scene 2 Fan status 3 Occupancy status 4 Temperature setpoint status 5 Lighting scene menu 6 Blinds scene menu Refer to the table below to configure each of the comfort parameters as needed: Occupancy To configure the occupancy, tap repeatedly on the occupancy status icon to scroll through the different occupancy statuses. Fan Speed To configure the fan speed, tap repeatedly on the fan status icon to be able to scroll through the different fan statuses. Lighting The lighting icon allows you to enable or disable lighting control. Use the scroll arrow to access the other lighting groups if necessary (up to 8 groups). The available lighting groups depend on the building settings. You can then set each group of light to OFF (0%), ON (100%) or not controlled (icon is grayed out) by tapping the matching lighting group icon. Page 15 / 20
16 Datasheet EN Issue Lighting pictogram 2 Lighting group 1 (an = 100 %) 3 Lighting group 2 (aus = 0 %) 4 Lighting group 3 (disabled) Sunblinds The sunblind icon allows you to enable or disable sunblind control. Use the scroll arrow to access the other sunblind groups if necessary (up to 8 groups). The available sunblind groups depend on the building settings. You can then set each group of sunblinds to open ( ), closed ( ) or not controlled (icon is grayed out) by tapping the matching sunblind group icon Blinds pictogram 2 Blinds group 1 (open) 3 Blinds group 2 (closed) 4 Blinds group 3 (disabled) Setpoint You can change the temperature setpoint by tapping the temperature setpoint status icon. The values are then scrolling following the sequence shown below: Scene Deactivation In order to deactivate a scene, proceed as follows: Tap and hold the scene icon that corresponds to the scene which you wish to deactivate until the corresponding scene menu appears. Tap repeatedly each menu icon until it is grayed out. Tap any main menu icon to escape the scene menu and return to the home screen. The selected settings are saved until the next modification. Page 16 / 20
17 Issue Datasheet EN RBU130-RJ/xx Configuration - Installation Mode The Installation Mode allows you to define the number of lighting and blind groups connected to the controller and to choose the unit of the temperature display as well as defining the screen standby delay. Entering Installation Mode Keep the Kieback&Peter logo pictogram pressed until the password screen appears. Dial the Installation Mode password (9995) and tap "Validation". You are now navigating in the Installation Menus. Tapping on the pictogram of the active Sleep Timer Menu allows you to cycle to the Lighting and Blinds Groups Menus and to the Temperature Unit Menu as shown hereunder. NOTE In Installation Menus, the selected setting is portrayed less colorful than the other options. Screen Sleep Timer Menu With the screen sleep timer you can set a period after which the screen turns off. The screen sleep timer is set by entering the numbers of minutes you want before the screen turns off after last action (maximum 10 minutes) and stored when tapping validation. When "0" is set, the sleep timer is disabled. Lighting Groups Menu You can choose how many lighting groups you want to set by tapping the matching pictogram. 2 groups 4 groups 8 groups Blinds Groups Menu You can choose how many blinds groups you want to set by tapping the matching pictogram. 2 groups 4 groups 8 groups Temperature Unit Menu You can set the temperature visual display unit by tapping the matching pictogram. Celsius degrees Fahrenheit degrees Page 17 / 20
18 Datasheet EN Issue RBU130-RJ/xx dvanced Technician Mode The dvanced Technician Mode allows you to access and manage a part of the controller s registry. Entering dvanced Technician Mode Keep the Kieback&Peter logo pictogram pressed until the password screen becomes visible. Enter the password (9994) and tap "Validation". The dvanced Technician Mode screen then appears. Choose the Read/Write mode you want to operate in by tapping the access right pictogram to switch from one mode to the other: RED: view the different parameters WRITE: set the different parameters Registry Management Reading a registry value Enter the dvanced Technician Mode. Dial the registry number (see Registry Table hereunder). Press "Validation". The register number is recalled above the read/write icon and the value assigned to this registry number is displayed. Writing a registry value Enter the dvanced Technician Mode. Dial the registry number (see Registry Table hereunder). Press "Validation". The register number is recalled above the read/write icon. Enter the desired value. Press "Validation". The value is stored and the registry number reminder disappears.! CUTION You must exit and re-enter the dvanced Technician Mode to update the controller in order to make the new registry settings effective. Entering an invalid value will lead to a flashing "xxx" and the reminder keeps being displayed. Page 18 / 20
19 Issue Datasheet EN Registry Table Registry Parameter Read ction Write ction 01 Occupancy mode 02 BMS temperature setpoint 03 mbient temperature Read occupancy Unoccupied=0 Occupied=1 Standby=3 Read temperature setpoint (5 C C) Read the ambient temperature according to the controller's configuration (5 C...36,9 C; +/- 0,1 C) 04 Fan speed Read fan speed Off=0 Slow=1 Medium=2 Fast=3 uto=4 05 Temperature Offset Read temperature offset from 0 to 12; 0 = -3K; 6 = 0K; 12= +3K 06 HVC Mode Read HVC Mode 0=uto 1=Heat 2=Cool 6=Off 7=Test 9=Fan only 07 Regulator's outputs 08 Window contact 09 Window contacts synthesis Read the output value of the regulator, displayed as a percentage of the maximum output. Read window contact closed window (open contact) = 0 open window (closed contact)=1 Read window contacts synthesis all windos closed = 0 at least 1 open window =1 10 not in use 11 Change over Read change over mode mode inactive=0 active=1 12 Installation configuration 13 uxiliary contact 14 Window contact state 15 Displayed temperature source Read installation configuration (1..20, see documentation of the controller) Read auxiliary contact open contact=1 closed contact=0 Read window contact state open contact=1 closed contact=0 Read displayed temperature source (0..9, see documentation of the controller) 16 not in use 17 not in use 18 not supported 19 not supported 20 not supported Write Occupancy Unoccupied=0 Occupied=1 Standby=3 not in use Clamp the ambient temperature to check the functioning of the control system (5 C...36,9 C; +/-0,1 C) Write fan speed Off=0 Slow=1 Medium=2 Fast=3 uto=4 Write temperature offset from 0 to 12; 0 = -3K; 6 = 0K; 12= +3K not in use not in use Write window contact closed window (open contact) = 0 open window (closed contact)=1 not in use Write change over mode inactive=0 active=1 Write installation configuration (1..20, see documentation of the controller) not in use not in use Read displayed temperature source (0..9, see documentation of the controller) Page 19 / 20
20 Datasheet EN Issue Registry Parameter Read ction Write ction 21 Channel number 22 Icons management from the controller Read the channel number associated to the RBU130-RJ/xx (1 to 4) when associated to a multiple RJ9 input device. numbering activation = (1 to 4) numbering deactivation = 0 Read controller icon display management mode controller icon display commands are taken into account = 0; ;controller icon display commands are not taken into account = 1 23 Dew point Read the dew point contact state (0,1) 24 Status des Read the alarm contact state (0,1) larmkontakts V Eingangsstatus Read the 0-10 V input state (0,1) Write the channel number associated to the RBU130-RJ/xx (1 to 4) when associated to a multiple RJ9 input device. numbering activation = (1 to 4) numbering deactivation = 0 Write controller icon display management mode controller icon display commands are taken into account = 0; ;controller icon display commands are not taken into account = 1 not in use not in use not in use 26 not in use 27 not in use 28 not in use 29 not in use 30 Module Reset not in use Module Reset Page 20 / 20
HT12, HTF12 Room humidity/temperature sensor
Issue 2016-11-09 Datasheet 1.40-20.012-01-EN Room humidity/temperature sensor pplication The HT12 and HTF12 are used for continuous measurement the relative humidity and room temperature in homes and offices.
More informationTD11..15, TDF Room Temperature Sensors
Issue 2011-08-30 Datasheet 1.10-10.010-01-EN Room Temperature Sensors pplication TD11..15 and TDF12..15 are used to measure the room temperature. The temperature sensors are used in conjunction with all
More informationTLD1..TLD4 Duct Temperature Sensors
Issue 2015-07-08 Datasheet 1.10-11.010-01-EN Duct Temperature Sensors pplication The sensors are used as controlled variable sensors for duct installation in all outside-temperature controlled or fixed-value
More informationTPC35 Display and operator panel
Issue 2014-08-06 Datasheet 2.70-10-435-01-EN Display and operator panel pplication The is a remote display and operator panel for BMR410 and DDC420. It has an active matrix color LCD touchscreen with a
More informationTPC84 Display and Operator Panel
Issue 2014-08-06 Datasheet 2.60-10.084-01-EN Display and Operator Panel pplication The is a remote display and operator panel. It has an active matrix color LCD touchscreen with a screen size of 21,3 cm
More informationRBW301-C, RBW302-C, RBW304-C, RBW305-C Room Control Module
Issue 2011-04-01 Datasheet 1.10-60.010-01-EN Room Control Module pplication are room control modules with displays for connecting to RCC200-L or RCN200-L room controllers. Different variants with a graded
More informationRCN122-L technolon Room Controller. Application. RCN122-L technolon Room Controller. Product Description
Issue 2014-10-20 Datasheet 2.80-10.222-01-EN pplication The is a bus-communicating room controller for fan convectors, with heating and cooling coils and blind control for fan coil applications. It communicates
More informationTPC56 Display and operator panel
Issue 2013-06-26 Datasheet 2.70-10-456-01-EN Display and operator panel pplication The is a remote display and operator panel for BMR410 and DDC420. It has an active matrix color LCD touchscreen with a
More informationTPC70Display and Operator Panel
Issue 2017-09-13 Datasheet 2.60-10.070-01-EN Display and Operator Panel pplication The is a remote display and operator panel. It has a color TFT touchscreen with a screen size of 7 / 17,8 cm. The can
More informationRCN200-L Room Controller
Issue 2014-10-30 Datasheet 2.80-30.200-01-EN Room Controller pplication The is a LON bus-capable room controller for energy-efficient temperature, air quality and humidity control. It can be used with
More informationIT554 VPN Router IT554. Product Description
Issue 2011-11-08 Datasheet 4.30-50.554-01-EN VPN Router pplication is a VPN router with client functionality and customized software that enables the secure transfer of encrypted data between controllers
More informationRCN132-L, RCN132-L-S1 technolon Room Controller
Issue 2014-10-21 Datasheet 2.80-10.232-01-EN technolon Room Controller pplication The is a bus-communicating room controller for VV (variable-air-volume) damper control with heating and cooling coils and
More informationBMD4032 Input/output module
Issue 2015-08-21 Datasheet 2.60-70.02-01-EN Input/output module pplication The input/output module with 2 digital inputs or outputs receives System 000 binary signals and activates binary control functions.
More informationDDC110S Room Control Modul With LCD Display
Issue 2012-01-26 Datasheet 1.10-31.110-01-EN Room Control Modul With LCD Display nwendung The bus-capable room control module with LCD display is used as part of the DDC3000 and DDC4000/BMR automation
More informationImportant Information Regarding Product Safety...2 Item...3 Technical Data...3 Dimensions...4 Connection...4 Mounting...5 Maintenance...
Issue 2013-10-24 Datasheet 1.40-21.450-01-EN Room Humidity/Temperature Sensor pplication The room humidity/temperature sensor with an integrated measurement converter is used for measuring the relative
More informationFBS51/04 Gateway-Module For M-Bus with 6 counters
Issue 2014-11-26 Datasheet 2.50-40.151-01-EN Gateway-Module For M-Bus with 6 counters pplication The Gateway Module is used to connect a maximum of 6 meters of external equipment to the BMR or DDC420 via
More informationFBM034 and FBM034W Fieldbus Input Modules
Issue 2014-10-01 Datasheet 2.50-30.034-31-EN FBM034 and FBM034W Fieldbus Input Modules pplication With four analog inputs, fieldbus input modules FBM034 und FBM034W record the signals of remote devices
More informationSBM52/04 Input / Output Module For M-Bus with 99 counters
Issue 2014-11-19 Datasheet 2.50-40.052-31-EN Input / Output Module For M-Bus with 99 counters pplication The is used to connect a maximum of 99 meters for external equipment to DDC controller DDC3000/DDC4000
More informationGLT-M002-GLTM GLT-M002-GLTM. Product Description
Issue 2011-07-19 Datasheet 4.70-10.013-01-EN pplication The GSM modem connects the building management system to the DDC system of the operational plant via the cellular network. The DDC system can then
More informationRCN155-L, RCN151-L Room controller
Issue 2018-05-03 Datasheet 2.80-10.155-01-EN Room controller pplication The is a room controller for stand-alone use or use in a LON network. For direct communication with other LON components, the is
More informationNOTE Hinweis: Note the special features of firmware updates provided by EPROM-Tausch (see page 4).
Issue 2014-11-19 Datasheet 2.50-40.051-31-EN Switch cabinet bus module with M-Bus input for 32 counters pplication The switch cabinet bus module is used to connect a maximum of 32 counters for external
More informationSBM51/04 Switch cabinet bus module For M-Bus with 32 counters
Issue 2012-08-28 Datasheet 2.50-40.051-31-EN Switch cabinet bus module For M-Bus with 32 counters pplication The switch cabinet bus module is used to connect a maximum of 32 counters for external equipment
More informationFBM018 and FBM018W Fieldbus Input Modules
Issue 2014-05-27 FBM018 and FBM018W Fieldbus Input Modules pplication With 8 digital inputs, the FBM018 und FBM018W Eingabe-Modul Feldbus record the signals from remote devices in DDC3000 and DDC4000/BMR
More informationCommissioning. IT554 VPN Router
Issue 2012-01-23 Datasheet 4.30-50.554-11-EN VPN Router pplication is a VPN router with client functionality and customized software that enables the secure transfer of encrypted data between controllers
More informationRCN420-B Room controller
Issue 2017-07-20 Datasheet 2.80-30.420-01-EN Room controller pplication The is a Cnet-capable room controller for energy-efficient temperature, air quality and humidity control. It can be used with customer-specific
More informationIT560 VPN router IT560. Commissioning
Issue 2018-02-22 Datasheet 4.30-50.560-11-EN VPN router pplication is a VPN router with server functionality and customized software that enables the secure transfer of encrypted data between controllers
More informationFBU410 Input/ Output Modulel
Issue 2016-10-12 Datasheet 2.50-30.410-01-EN Input/ Output Modulel pplication The Ein-usgabe-Modul with 4 relay outputs and 6 universal inputs/outputs controls and records the signals of remote devices
More informationImportant Information Regarding Product Safety...2 Item...3 Technical Data...3 Installation Dimensions...4 Mounting...5 Connection...
Issue 20160127 Datasheet 2.5010.20001EN Controller pplication The is a central control unit for closedloop and openloop control, optimizations and monitoring functions. The controller meets the following
More informationGLT-D004-TFA4 Color Ink Jet Printer A4
Issue 2012-08-13 Datasheet 4.65-20.004-11-EN Color Ink Jet Printer 4 pplication You can use the printer described in this document to print documents (for example plant schematics and trend curves) from
More informationRCC200-L Room Controller
Issue 2014-04-14 Datasheet 2.80-20.200-01-E Room Controller pplication The is a O bus-capable room controller for energy-efficient temperature, air quality and humidity control. It can be used with onmark-compliant
More informationBCU070-L technolon Switch Interface. Application. BCU070-L technolon Switch Interface. Product description
Issue 2007-10-01 Datasheet 2.80-50.070-01-EN pplication The technolon switch interface binary controller for flush mounting, 7 BI / 2 BO. Bus-capable switch interface with open communication using the
More informationRCW11x-L Room Controller Technolon. Application. Product Description. RCW11x-L Room Controller Technolon
Issue 2008-04-03 Datasheet 2.80-20.100-01-EN pplication The technolon room controllers RCW112-L, RCW113-L, RCW115-L, RCW116-L enable you to control the temperature of individual rooms by means of radiator,
More informationDDC4200e Automation Station with Operator Function
Issue 2014-07-08 Datasheet 2.60-10-210-01-EN utomation Station with Operator Function pplication Color touchscreen with BCnet communication Standalone station with operator function for closed-loop and
More informationBMR410 Controller BMR410. Product Description
Issue 2011-04-27 Datasheet 2.70-10.411-01-EN Controller pplication The is a DDC controller for regulating, controlling, monitoring and optimizing heating, ventilation and air conditioning systems. The
More informationDDC420 Automation Station
Issue 2016-09-26 Datasheet 2.70-10.420-01-EN utomation Station pplication is a controller for closed-loop and open-loop control, monitoring and optimizing heating, ventilation and air conditioning systems.
More informationDDC4200e Controller with Operator Function
Issue 2017-04-13 Datasheet 2.60-10-210-01-EN Controller with Operator Function pplication Color touchscreen with BCnet communication Standalone station with operator function for closed-loop and open-loop
More informationSmart-Sense Room Control. End-User Manual
Smart-Sense Room Control End-User Manual Document Revision History: 1. Version 1.0 February 2012 2. Version 2.0 July 2013 3. Version 2.1 June 2013 Smart-Sense Room Control - User Guide v2.1 05DI-UGSSRCE-21,
More informationNote: Note the changed parameter functions due to firmware updates (see page 5).
Gateway Module for Danfoss Frequency Inverters pplication With the gateway module, you can connect up to eight Danfoss frequency inverters (FIs) of various types using the Danfoss bus with the DDC3000/DDC4000
More informationSBM51/05 gateway module for Berg network monitoring
Issue 2016-09-08 Datasheet 2.50-40.051-52-EN gateway module for Berg network monitoring pplication The gateway module with an RS485 connection is used to connect up to 8 Berg network monitoring components
More informationGLT2200N BMS Network Operator Station
Issue 2011-10-21 Datasheet 4.10-20.200-36-EN BMS Network Operator Station pplication BMS network operator station for higher-level building management functions and for connecting controllers. Content
More informationAllure EC-Smart-Comfort Series
Datasheet Allure EC-Smart-Comfort Series Communicating sensors with Smart-Light and Smart-Blind add-on modules Overview Features & Benefits The Allure EC-Smart-Comfort Series are versatile communicating
More informationAllure EC-Smart-Comfort Series
Datasheet Allure EC-Smart-Comfort Series Communicating sensors with Smart-Light and Smart-Blind add-on modules Overview The Allure EC-Smart-Comfort series are versatile communicating sensor which provide
More informationDatasheet. Smart-Sense Room Control. 1/6. Remote Room Control Application for iphone, ipad, and Android devices.
Datasheet Smart-Sense Room Room Application for iphone, ipad, and Android devices Overview Applications The Smart-Sense Room application provides precise environmental zone control for temperature, fan
More informationActuating drive with spring return DSFY/16 Modulated actuating drive with spring return
ctuating drive with spring return DSFY/16 Modulated actuating drive with spring return Issue date: Feb. 27, 2006 Subject to change Contents Page Information about the device description... 2 Qualified
More informationWireless Small Actuator MAC-WSA
Wireless Small Actuator MAC-WSA MAC-WSA Wireless Small Actuator Application Wirelessly controlled, battery-powered small actuator for continuous closed-loop control systems. For thermostat valve bodies
More informationBMF400 Input/output module
BMF400 Input/output module Input/output module with six universal inputs/outputs and four floating relay outputs for function extensions of the BMR bus module controller. Issue date: December 6, 2006 Subject
More informationROUTER-2SHDSL-RAIL-001/01
Issue 2017-04-19 User Information Datasheet 4.30-50.027-85-EN ROUTER-2SHDSL-RAIL-001/01 ROUTER-2SHDSL-RAIL-001/01 Application The ROUTER-2SHDSL-RAIL-001/01 contains two SHDSL drivers and a four-port switch.
More informationUCU Room Display. Operation Modes. Features. Applications DATASHEET
DATASHEET UCU Room Display The UCU Room Display provides dedicated visually appealing Room Control display for use with UCU10FC/K Unitary Controller. The display allows the user to view and adjust selected
More informationRoom Temperature Controller
3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:
More informationInstallation Instructions
Dual EIB bus coupler Order no.: 1246 651, 1246 661, 1246 671 rmation The Gira SmartSensor is a product of the Instabus KNX/EIB System and complies with KNX/EIBA directives. The functions of the device
More informationDDC110-L1.. DDC110-L4 technolon Room Module
technolon Room Module DDC110-L1, DDC110-L2, DDC110-L3 and DDC110-L4 Single room control or room display and service module for single-room control in the LON network. With display of the room temperature
More informationEC-Remote Series. End-User Manual
EC-Remote Series End-User Manual Document Revision History: 1. Version 1.0 February 2012 2. Version 2.0 July 2013 EC-Remote Series - User Guide v2.0 05DI-UGECREM-20, Distech Controls Inc., 2012. All rights
More informationProduct and function description
GAMMA instabus The following display and operating functions can be configured: switching, switching with forced control, dimming, sun protection control, recall and save scenes, sending and displaying
More informationNeutrino-GLT Server BACnet TM Protocol Implementation Conformance Statement (PICS) Version 3
Issue date: 2005-05-01 data sheet 4.10-10.701-03-en BCnet TM Protocol Implementation Conformance Statement () Version 3 Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications
More informationSemi Flush-mount Room Temperature Controllers with LCD
3 076 RDF300, RDF300.02, RDF340 RDF400.01 Semi Flush-mount Room Temperature Controllers with LCD for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment
More informationSmartStruxure SmartStruxure Lite ZENO InnPoint. ZENOcontrols.com. compatible with
Room Controller Low Voltage Fan Coil Controller and Zone Controller Application specific controller with customizable covers and screen colours. The is a low voltage fan coil terminal equipment controller
More informationProduct and Application Description
Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design
More informationRXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication
3 870 DESIO RXB Room controller for chilled ceilings and radiators with EIB bus communication RXB10.1 The RXB10.1 controller is used for temperature control in individual rooms: For chilled ceilings and
More informationProduct and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)
Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow
More information252F 5WG FB_1 DELTA
Product DELTA i-system DELTA profil Fan-Coil Unit Operator Panels Hotel titanium white 5WG1 237-2FB11 pearl grey 5WG1 252-2FB01 carbon metallic 5WG1 237-2FB21 titanium white 5WG1 252-2FB11 aluminum metallic
More informationColour Touch Panel 3.5
Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R Colour Touch Panel 3.5 User manual-ver. 1.2 CHTF-35/01.1 CHTF-35/01.2.21 CHTF-35/01.2.22 CHTF-35/01.2.24 KNX/EIB Intelligent Installation Systems
More informationDDC4200 BACnet TM Protocol Implementation Conformance Statement (PICS) Version 1
Issue date: 2008-05-12 data sheet 2.60-10.200-03-en DDC4200 BCnet TM Protocol Implementation Conformance Statement () Version 1 Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications
More informationRoom Temperature Controller
3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:
More informationYou, in an homy and environmental world
You, in an homy and environmental world www.eelectron.com Building and Home Evolution 24/03/11 1 What s this? www.eelectron.com Building and Home Evolution 24/03/11 2 NOT A SWITCH You, in an homy and environmental
More informationSemi flush-mounted room temperature controllers with LCD
s 3 077 RDD310 RDE410 Semi flush-mounted room temperature controllers with LCD For heating systems RDD310 RDE410 RDD310 and RDE410 features: Operating voltage AC 230 V 2-position control with On / Off
More informationSemi flush-mounted room temperature controllers with LCD
s 3 077 RDD310 RDE410 Semi flush-mounted room temperature controllers with LCD For heating systems RDD310 RDE410 RDD310 and RDE410 features: Operating voltage AC 230 V 2-position control with On / Off
More informationMaster room unit for RRV controllers
2 722 Master room unit for RRV controllers 2 wire bus connection QAX850 Multifunctional, digital room unit for installer and end-user interface with RRV controllers. Use Use Application Room unit in combination
More informationField selectable application type and room module series, via dip-switches on controller
TUC03 Plus Configurable Terminal Unit Controller Product bulletin The TUC03 Plus configurable Terminal Unit Controller is specifically designed to provide an improved BACnet integration. It allows the
More information7-day room temperature controller
s 2 208 7-day room temperature controller Heating applications REV34.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large
More informationSER8300 Room Controller
SER8300 Room Controller Line Voltage Fan Coil Controller with SC3000 Relay Pack Application specific controller with customizable covers and screen colors. The SER8300 is a line-voltage fan coil room controller
More informationFCU-4 FAN COIL CONTROLLER
FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced
More informationSTRA-17 Room controller. Installation and maintenance manual. Content
Content Installation preparations... Wiring diagram...3 Display handling...5 Technical data...6 Configuration...7 Operating modes...7 Controller modes...7 Activation operating modes...7 Control states...8
More informationZONETOUCH DAMPER CONTROL SYSTEM Operation Manual
ZONETOUCH DAMPER CONTROL SYSTEM Operation Manual www.zonemaster.com.au www.polyaire.com.au 2012 Polyaire Pty Ltd TABLE OF CONTENTS 1) Features 2 2) Wall Controller Layout (Touchpad) 2 3) Manual On/Off
More informationRoom Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack
Room Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack Application specific controller with customizable covers and screen colours. The SER8300 is a line-voltage fan coil terminal
More informationSE8300 Room Controller
SE8300 Room Controller Low Voltage Fan Coil Controller and Zone Controller Application Specific low voltage Room Controller with customizable covers and screen colors. Suitable for commercial and high
More informationOverview. Integrated fail-safe mode in case of communication or power failure to comply with most regulation requirements
Datasheet Lighting and Sunblind Expansion Modules Overview Applications When connected to any compatible HVAC programmable controller, the ECx-Light/Blind expansion modules allow to control up to 8 lights
More informationRoom Temperature Controllers
3 021 Room Temperature Controllers for two-pipe fan coil units RCC10 Output for on / off valve actuator Outputs for three-speed fan Control depending on the room or return air temperature (RCC10) Automatic
More informationthanos RS485 Modbus Application Functions Multifunction Room Operating Unit Datasheet
thanos RS485 Modbus Multifunction Room Operating Unit Datasheet Subject to technical alteration Issue date: 16.09.2015 603591 Application The thanos touch screen room operating unit has integrated temperature
More informationAirTouch 2 Zone Control System
AirTouch 2 Zone Control System User Manual www.polyaire.com.au 2016 Polyaire Pty Ltd Liability Please read the instructions before installing this Zonemaster Zoning Control System. Polyaire Pty Ltd does
More informationPre-programmed room controller with display and communication
revision 01 2014 RC-C3DOC Pre-programmed room controller with display and communication RC-C3DOC is a complete pre-programmed room controller from the Regio Midi series intended to control heating, cooling
More informationInstallation and Operation Back-UPS BR1000G-IN / BR1500G-IN
Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service
More informationRCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs
revision 01 2015 RCF-230CAD Communicating room controller for fan-coil applications with two analogue 0...10 V DC outputs RCF-230CAD intended to control heating and/or cooling in 2- or 4-pipe installations.
More informationQAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC
1 648 Desigo RXC Flexible room unit for integrated operation of HVAC, lighting and blinds in individual rooms; with LONMARK -compatible bus communication QAX50.1 QAX50.5 QAX51.1 QAX51.5 Room temperature
More informationEY-RU 355: Room operating unit, ecounit355
Product data sheet 1.1 94.041 EY-RU 355: Room operating unit, ecounit355 How energy efficiency is improved Individual setting of occupancy and absence as well as room setpoint correction, control of lights
More informationSuitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.
TUC03 Configurable Terminal Unit Controller Product Bulletin The TUC03 Configurable Terminal Unit Controller is designed specifically to provide direct digital control of terminal unit applications with
More informationRoom unit with PPS2 interface
1 642 Desigo RX Room unit with PPS2 interface for use with: QAX33.1 devices of the ranges Desigo RXC, RXB, RXL, and RXA (PPS2) Desigo PX Automation stations 1) devices with a PPS2 interface Room temperature
More informationTITAN S8. Portable Data Acquisition Logger. Product User Guide
TITAN S8 Portable Data Acquisition Logger Product User Guide Table of Contents 2 General Features... 3 Device Overview... 3 External Features... 3 Device Orientation... 4 Device Inputs... 5 Sensor Types
More informationTAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta
TAC Xenta TAC Xenta 101-VF 3-Speed Fan Coil Controller TAC Xenta 101-VF is a zone controller intended primarily for fan coil applications with the ability to control fans with multiple speeds, with one
More informationLONMARK Certified Powered Fan Coil Configurable Controllers. Overview
Datasheet RCL-PFC Series LONMARK Certified Powered Fan Coil Configurable Controllers Overview Applications Meets the requirements of the following applications: Fan Coil Units Unit Ventilators Chilled
More informationRoom unit with PPS2 interface
1 626 Room unit with PPS2 interface for use with: controllers with a PPS2 interface QAA88.3 Room temperature measurement Key buttons for adjustment of the room temperature setpoint Key buttons for operating
More informationKNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function
Push button sensor 3 Plus 2-gang F100 Order No. : 2042 xx Push button sensor 3 Plus 3-gang (1+2) F100 Order No. : 2043 xx Push button sensor 3 Plus 6-gang (2+4) F100 Order No. : 2046 xx Operating instructions
More informationRCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs
revision 11 2013 RCF-230CD Communicating room thermostat for fan-coil applications with on/off outputs RCF-230CD intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint and fan
More informationRCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater
revision 03 2012 RCF-230CTD Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater RCF-230CTD is a room controller intended
More informationTouch room operator unit 4.3 inch
s 9 295 Desigo Touch room operator unit 4.3 inch QMX7.E38 High quality, TFT display 4.3" with 262,000 colors and glass surface in aluminum metal housing for use with Desigo TRA. Resolution: 480 x 800 pixels
More informationRC-CDTO. Pre-programmed room controller with display, communication and three-point control
revision 02 2016 RC-CDTO Pre-programmed room controller with display, communication and three-point control RC-CDTO is a complete pre-programmed room controller from the Regio Midi series intended to control
More information2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.
TITAN S8 Portable Data Acquisition Logger PRODUCT USER GUIDE To view the full MadgeTech product line, visit our website at madgetech.com. TABLE OF CONTENTS 2 Product Overview 5 User Interface 14 Logging
More informationRoom controller STRA-17
Room controller STRA-17 Application example Room 2 Room 3 Room 4 SCADA EXOline alt. RS485 Modbus Transformer STRZ-24 (Required component) STRA-17 is a preprogrammed room controller intended to control
More informationRCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs
revision 04 2016 RCF-230CAD Room controller with communication for fancoil applications with two analogue 0...10 V DC outputs Intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint
More informationMTN MTN
KNX KNX Multitouch Pro Multitouch with RTCU 1920/1.1 Application description This document describes the software application 1920/1.1. The software application is designed to program the KNX Multitouch
More informationOverview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.
Datasheet Lighting Expansion Modules Overview Applications On/Off lighting 1-10 V dimming lighting The Expansion Modules are microprocessor-based interfaces that extend the number of inputs and outputs
More information