Multifunctional Gate Box MGB

Size: px
Start display at page:

Download "Multifunctional Gate Box MGB"

Transcription

1 Multifunctional Gate Box MGB More than safety.

2 Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 98. Around the world the Swabian specialists in motion sequence control for mechanical and systems engineering. EUCHNER s history began in 90 with the establishment of an engineering office by Emil Euchner. Since that time, EUCHNER has been involved in the design and development of switchgear for controlling a wide variety of motion sequences in mechanical and systems engineering. In 95, Emil Euchner founded EUCHNER + Co., a milestone in the company s history. In 95, he developed the first multiple limit switch to this day a symbol of the enterprising spirit of this familyowned company. Automation Safety ManMachine Today, our products range from electromechanical and electronic components to complex system solutions. With this wide range of products we can provide the necessary technologies to offer the right solution for special requirements regardless of ether these relate to reliable and precise positioning or to components and systems for safety engineering in the automation sector. EUCHNER products are sold through a worldwide sales network of competent partners. With our closeness to the customer and the guarantee of reliable solutions throughout the globe, we enjoy the confidence of customers all over the world. Quality, reliability, precision Quality, reliability and precision are the hallmarks of our corporate philosophy. They represent concepts and values to ich we feel totally committed. At EUCHNER, quality means that all our employees take personal responsibility for the company as a ole and, in particular, for their own field of work. This individual commitment to perfection results in products ich are ideally tailored to the customers needs and the requirements of the market. After all: our customers and their needs are the focus of all our efforts. Through efficient and effective use of resources, the promotion of personal initiative and courage in finding unusual solutions to the benefit of our customers, we ensure a high level of customer satisfaction. We familiarize ourselves with their needs, requirements and products and we learn from the experiences of our customers own customers. EUCHNER More than safety. Quality made by EUCHNER

3 Contents Multifunctional Gate Box MGB General Information System Overview and Selection Aid 7 Approvals and Explanation of Symbols 8 System Family MGBAP 9 Interlocking sets MGBL0AP... 0 Locking sets MGBLAP... Locking sets MGBLAP... Technical data, dimension drawings and connection examples 8 System Family MGBAR Interlocking sets MGBL0AR... Locking sets MGBLAR... 0 Locking sets MGBLAR... Technical data, dimension drawings and connection examples 5 MGBAR MGBAP Expansions and Accessories for MGBAP and MGBAR 59 System Family MGBPN 7 Locking sets MGBLPN... 7 Locking sets MGBLPN Technical data and dimension drawing 80 MGBPN Item Index 8 Item index by item designation 8 Item index by order numbers /0

4 General A handle on the future The MGB (Multifunctional Gate Box) is a unique interlocking or guard locking system for the protection of safety doors on machines and systems. The MGB offers that little bit more: it is more than a safety switch, more than a bolt, and offers a lot more functionality! A system that can grow with your needs Even the basic system comprising handle module and evaluation module (as interlocking module or locking module) includes numerous functions. Whether interlocking, guard locking, escape release or other functions such as buttons for start/stop, emergency stop, etc. the MGB meets all your requirements for safetyrelated applications. Or with an additional control module straight away In the wide variety of different MGBs, you will definitely find the right one for your application. If not, using the control module you can add lamps, buttons or even completely different operating functions. The control module is permanently fastened to the evaluation module using the connection set. Be certain of compliance with standards Performance Level e in accordance with EN ISO 89 or SIL in accordance with EN 606 even with the basic system you meet all these requirements. Also the requirements of EN 088 for protection against tampering are met automatically, as each evaluation module is permanently assigned to a handle module in the unicode version. And if your needs grow, the MGB system grows with them. Due to the sophisticated modular design, the evaluation module can quickly become a small operator panel. Saves time and money! Evaluation module (as interlocking module or locking module) Mechanical release For releasing the guard locking e.g. in case of a power failure. Everything at a glance The LED indicator continuously provides you with all important system information. Diagnostics and status check! PLe/Cat. with just one set!!! Space for ideas... Control elements and indicators in one housing turn the MGB into an allrounder. With start button, enable and emergency stop or other functions, the evaluation module becomes a small control terminal. Solid door stop A mechanical door stop is permanently integrated into the evaluation module. A marking on the stop makes adjustment easier. Generous tolerances

5 General Safety remains the most important goal Are you locked in inside the danger area? The optional escape release is intuitive to operate! Whether in the event of a power failure or active guard locking the red door handle is simply pressed down to leave the danger area quickly. For protection en working in the danger area you can block the bolt tongue using up to padlocks in the integrated lockout mechanism. Unintentional activation of the interlocking / guard locking is prevented. Is the lockout mechanism to extend automatically en the door is open? No problem with the right handle module. Easy to mount and sophisticated design All MGB modules are optimized for use on fences made of aluminum profiles or steel frames. The MGB is equally suitable for doors hinged on the left or right. Both mounting and changing the actuating direction can be undertaken particularly quickly and easily. Usage on safety doors that are not constructed of profiles, works of course just as well. The adjustment of safety doors in fences changes over time. With ± mm tolerance in the x direction as well as ± 5 mm in the z direction, the MGB is right there ere the problem starts. Nevertheless, if a safety door should be even more out of adjustment, the large funnel in the evaluation module "catches" the bolt tongue and guides it into the center position. Bolt tongue, bolt guide and insertion funnel will also withstand occasional slamming of the door. Robust metal parts protect the MGB against this problem as well. To prevent injuries, the bolt tongue remains retracted with the door open. Do you use hinged doors or sliding doors? The MGB is suitable for both. This aspect eases spare parts stockholding. You always have an overview Four builtin LEDs continuously provide all the necessary system information: Power supply available, door closed, bolt tongue inserted, guard locking activated, diagnostics messages everything can be seen clearly at a glance. This information is of course also available to the control system. (Read on the next page at else there is in the MGB!) Very simple mounting Escape release module Rapid escape Open Escape release (optional) The safety system MGB can be complemented by an escape release. The escape release enables persons o are accidentally locked in to open the locked door from inside the danger area. Flexible combinations (kit system) Handle module Lockout mechanism The bolt tongue can be blocked for cleaning and service with up to padlocks. Optionally with automatically extending second lockout mechanism on the side. Intelligent bolt tongue The bolt tongue is reliably detected by transponder as soon as it is inserted in the evaluation module. Door handle standard The MGB has a robust door handle that can be rotated in 90 steps to suit the installation. Safety provided in any situations 5

6 General Sophisticated accessories Whether you need mounting plates for easier attachment, preassembled cables or a long escape release actuator axis (as the safety door need to be very thick), you will find all you need in the accessories section. Economical according to standards All devices in the family AR can be wired directly in series in a socalled AR series connection without reducing safety or the PL. As a consequence evaluation units are saved. AR devices are also available in the EUCHNER series CES and CET. The family MGBAP is particularly suitable for the protection of individual safety doors. If series connection is not necessary, can then be saved. This version has different timing to the AR version. Seamless integration by means of bus connection In the PROFINET version we now also make the easier for you. You define ich element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary PROFINET input and output bytes required. Comprehensive diagnostics information in the form of PROFINET messages makes troubleshooting quick and specific. Due the typical ease with ich parameters can be set in PROFINET, even the replacement of the system in case of service is a simple matter and can be undertaken in a few minutes. Interlocking or guard locking? Functions of the versions MGBL0, MGBL and MGBL compared Interlocking (MGBL0, without guard locking) Together with a handle module, the interlocking module makes it possible to interlock the control of moveable safety guards. The combination also serves as a mechanical door stop at the same time. The following switchon condition applies to the safety O A and O B (see also System status table): Safety guard closed (however can be opened at any time) Bolt tongue inserted in the interlocking module The interlocking module detects the position of the safety guard and the position of the bolt tongue. The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle. Guard locking (MGBL and MGBL) Together with a handle module, the locking module makes it possible to lock moveable safety guards. The combination also serves as a mechanical door stop at the same time. The following switchon condition applies to the safety O A and O B (see also System status table): Safety guard closed Bolt tongue inserted in the locking module Locking arm in locking position (the door cannot be opened) The locking module detects the position of the safety guard and the position of the bolt tongue. The position of the guard locking is also monitored. The bolt tongue in the handle module is moved into and out of the locking module by actuating the door handle. When the bolt tongue is fully inserted in the locking module, the locking arm locks the bolt tongue in this position. Depending on the version, this locking is by spring force or solenoid force. Version MGBL: The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closedcircuit current principle, mechanically locked). Version MGBL: The locking arm is kept in locked position by solenoid force and unlocked by spring force en the solenoid is switched off (opencircuit current principle, electrically locked). Warning! The safety guard can be opened immediately in the event of interruption of the solenoid power supply with the version MGBL...! Usage only in special cases in accordance with strict evaluation of the accident risk (see EN 088:995+A:008, section 5.5)! Example: If the risk of accidental locking inside a safety guard during a power failure is higher than the risk of ineffective guard locking. Connection to evaluation units or safe control systems The safety system MGB can be connected to almost any safe evaluation unit or to any safe control system. For this purpose the short circuit monitoring on the control system is disabled this function is performed by the MGB. Performance Level e is of course retained. The advantages of the Multifunctional Gate Box MGB Suitable for all profiles (optimized for mounting on profiles from 0 50 mm) Tolerance ± mm in x direction, ± 5 mm in z direction Locking force 000 N The MGB withstands forces amounting up to 00 Joule Optional escape release with door handle Optional buttons and indicators can be integrated directly into the housing Stable metal stop prevents damage with bolt tongue extended Marking on the evaluation module as adjustment aid The actuating direction is easy to change without disassembly Hidden mounting holes with slots and metal mounting surfaces Housing material made of high quality, reinforced plastic Escape release can also be used on doors with double rebate There features are available in all devices in the families MGBAP and MGBAR Emergency release Connection by cable, max..5 mm² or plug connector Plug connector connection, either RC8 or M pin Series connection (only with system family AR, for description see above) Connection of buttons to common power supply DC V Connection of lamps to common ground Operation of guard locking via U CM as control input on PLC (only ma) Monitoring O = Door in closed position O = Bolt tongue inserted in the evaluation module (in case of guard locking ready for operation of the solenoid. In case of interlocking corresponds to safety ) O = Guard locking solenoid locked in position (in case of guard locking corresponds to safety ) O = Diagnostics, there is a fault

7 System Overview Safety System MGB System families at a glance The tables on this page provide you a quick overview of the features and strengths of the related product family as well as the possible expansions. What system families are available? System family Symbol Use MGBAP MGBAR MGBPN AP AR PN If series connection is not necessary, the number of terminals can be reduced using this system family. Linking of several safety guards on one shutdown path. As a consequence several safety doors can be very simply polled using one evaluation unit or two control system inputs. How to utilize the maximum functionality of the MGB in a Profinet environment. Ease of replacement and flexibility are in the foreground here. System families compared The tables provide you a quick overview of the features and strengths of the related product family as well as the possible expansions. System family Feature / special aspect MGBAP MGBAR MGBPN Separate operation Series connection Bus connection Simple diagnostics Little Key: Particularly suitable Suitable Not applicable / not possible Function / expansion Evaluation module with additional functions Control module with additional functions System family MGBAP MGBAR MGBPN Selection from existing versions, customerspecific version possible * Flexible configuration due to kit MGBC (only devices with cable ) Selection from existing versions, customerspecific version possible * Flexible configuration due to kit MGBC (only devices with cable ) Selection from existing versions, customerspecific version possible * Configuration from factory by EUCHNER Mounting plates Connection for enabling switch Escape release Key: Available in some versions Standard Optional or on request Not possible *) Note minimum order quantity of 50 pieces! Available in some versions Already contained in some sets, can be upgraded at any time. 7

8 General Approvals To demonstrate conformity, the Machinery directive also includes the possibility of type examination. Although all relevant standards are taken into account during development, we have all our safety switches subjected to additional type examinations by a notified body. Many of the devices listed in this catalog have been tested by the German Social Accident Insurance association (DGUV), formerly the employers' liability insurance association (BG), and are given in the lists from the DGUV. With the aid of the approval symbols listed below you can quickly see ich approvals are available for the related devices: Illuminated pushbutton Pushbutton not illuminated Explanation of symbols Devices with this symbol are type examined by the German Social Accident Insurance association (DGUV) formerly the employers' liability insurance association (BG) All MGB devices comply with the stipulations of Underwriter Laboratories (UL) and carry the symbol 0 0 LED Selector switch form V Keyoperated selector switch form V System families AP System family MGBAP for separate operation 0 Keyoperated selector switch form L AR System family MGBAR for separate operation or series connection with other AR devices PN System family MGBPN for operation in PROFINET environment Safety category/guard locking Cat. PLe Suitable up to category or Performance Level e in accordance with EN ISO 89 Guard locking for personal protection Controls and indicators Emergency stop according to ISO 850 Illuminated emergency stop Emergency stop with auxiliary contact Machine stop 8

9 Safety System MGB...AP... Complete sets system family MGBAP Interlocking or guard locking with handle module With escape release With buttons and emergency stop With plug connectors MGBAP Interlocking sets MGBL0AP... (without guard locking) 0 with controls and indicators 0 Locking sets MGBLAP... (guard locking by spring force) with controls and indicators Locking sets MGBLAP... (guard locking by solenoid force) 7 with controls and indicators with controls and indicators 6 Technical data 8 Dimension drawings 9 Connection examples 0 9

10 Safety System MGB...AP... Interlocking sets MGBL0AP... with controls or indicators AP Cat. PLe Interlocking (without guard locking) in accordance with EN 088 With cable or plug connector Integrated controls and indicators Details Connection for enabling switch The devices have an M plug connector for the direct connection of an enabling button (e. g. ZSA, order no. 0560). Label carrier Devices with label carrier have preformed recesses. The label carrier enclosed can be bonded in this recess (standard dimension.5 x 7 mm). Further information Dimension drawings see p. 9 Technical data see p. 8 Accessories and spare parts see p Ordering table Modules in the set Ordering data set Version/configuration scheme Interlocking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 056 Plug connector M for enabling switch incl. label carrier ye bu 006 right 0550 MGBL0HAPAR Plug connector M for enabling switch incl. label carrier ye bu 006 left 055 MGBL0HAPAL055 0

11 Safety System MGB...AP... MGBL0... Block and for controls and indicators X5.6 X5.5 X. X.5 X. X.5 X.7 X. X. X. X. X. X.6 UB DC V OV OA Safety OB UA 0V DC V (Aux Pwr) S S S Reset Monitoring Stufe E E E E EUCHNER ZSA 0560 RST X.6 O X5. O X5. O X5. H X. H X. H X.5 Connector M 5 BN RD BK WH Terminal assignment cable Terminal Designation Description X. to X.7 See X. to X. See X. U A Power supply, DC V (connected internally to X5.6) X5.6 U B Power supply, DC V (connected internally to X.) X.5 and X.6 0 V Ground (connected internally to X5.5) X.7 Not used X. to X. Not used X. O A ON en the door is closed and the bolt tongue Safety output channel A, is inserted in the interlocking module. X.5 O B ON en the door is closed and the bolt tongue Safety output channel B, is inserted in the interlocking module. X.6 RST X5. O X5. O X5. Not used X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the interlocking module. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5 and X.6) MGBAP

12 Safety System MGB...AP... Locking sets MGBLAP... (guard locking by spring force) with controls or indicators AP Cat. PLe Guard locking with guard lock monitoring in accordance with EN 088 With cable or plug connector Integrated controls and indicators Details Connection for enabling switch The devices have an M plug connector for the direct connection of an enabling button (e. g. ZSA, order no. 0560). Label carrier Devices with label carrier have preformed recesses. The label carrier enclosed can be bonded in this recess (standard dimension.5 x 7 mm). Illuminated emergency stop Emergency stop with illumination that can be controlled as required. Further information Dimension drawings see p. 9 Technical data see p. 8 Accessories and spare parts see p Ordering table Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 0976 Illuminated emergency stop, incl. label carrier Plug connector RC8 A 006 right 0977 MGBLHAPAR Plug connector M for enabling switch incl. label carrier ye bu B 006 right 0587 MGBLHAPAR Plug connector M for enabling switch incl. label carrier ye bu B 006 left 0588 MGBLHAPAL0588

13 Safety System MGB...AP... MGBL... Block and for controls and indicators A Plug connector RC UB DC V OV OA Safety OB UA 0V DC V (Aux Pwr) UCM S S H H Guard locking H Reset Monitoring S.A S.B S.B S.A RST O O O B X5.6 X5.5 X. X.5 X. X.5 X.7 X.7 X. X. X. X. X. X.6 MGBAP UB DC V OV OA Safety OB UA 0V DC V (Aux Pwr) UCM S S S Guard locking Reset Monitoring Stufe E E E E EUCHNER ZSA 0560 RST X.6 O X5. O X5. O X5. O X5. H X. H X. H X.5 Connector M 5 BN RD BK WH Terminal assignment plug connector RC8 Pin Designation Description U CM Control voltage for switching on and off the guard locking. S.A Emergency stop (channel A) S.A Emergency stop (channel A) O A Safety output channel A, ON en the door is closed and locked. 5 O B Safety output channel B, ON en the door is closed and locked. 6 U A U B 7 O 8 O Power supply, DC V Door monitoring output, ON en door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. 9 S.B Emergency stop (channel B) 0 O Monitoring output DIA, ON en the device is in the fault state. S.B Emergency stop (channel B) Not used RST V Ground Reset input, device is reset if DC V are applied to RST for at least s. See Terminal assignment cable Terminal Designation Description X. to X.7 See X. to X. See X. U A Power supply, DC V (connected internally to X5.6) X5.6 U B Power supply, DC V (connected internally to X.) X.5 and X.6 0 V Ground (connected internally to X5.5) X.7 U CM Control voltage for switching on and off the guard locking. X. to X. Not used X. O A Safety output channel A, ON en the door is closed and locked. X.5 O B Safety output channel B, ON en the door is closed and locked. X.6 RST X5. O X5. O X5. O X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Guard locking monitoring output, ON en the door is closed and locked. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5 and X.6)

14 Safety System MGB...AP... Locking sets MGBLAP... (guard locking by solenoid force) with controls or indicators AP Cat. PLe Guard locking with guard lock monitoring in accordance with EN 088 With cable or plug connector Integrated controls and indicators Details Connection for enabling switch The devices have an M plug connector for the direct connection of an enabling button (e. g. ZSA, order no. 0560). Label carrier Devices with label carrier have preformed recesses. The label carrier enclosed can be bonded in this recess (standard dimension.5 x 7 mm). Illuminated emergency stop Emergency stop with illumination that can be controlled as required. Further information Dimension drawings see p. 9 Technical data see p. 8 Accessories and spare parts see p Ordering table Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item Illuminated emergency stop, incl. label carrier Plug connector RC 8 A 006 right 0977 MGBLHAPAR Illuminated emergency stop, incl. label carrier Plug connector RC 8 A 006 left 0075 MGBLHAPAL Plug connector M for enabling switch incl. label carrier ye bu B 006 right 058 MGBLHAPAR Plug connector M for enabling switch incl. label carrier ye bu B 006 left 059 MGBLHAPAL059

15 Safety System MGB...AP... MGBL... Block and for controls and indicators A Plug connector RC UB DC V OV OA Safety OB UA 0V DC V (Aux Pwr) UCM S S H H Guard locking Reset Monitoring S.B S.B S.A RST O O O B X5.6 X5.5 X. X.5 X. X.5 X.7 X.7 X. X. X. X. X. X.6 MGBAP UB DC V OV OA Safety OB UA 0V DC V (Aux Pwr) UCM S S S Guard locking Reset Monitoring Stufe E E E E EUCHNER ZSA 0560 RST X.6 O X5. O X5. O X5. O X5. H X. H X. H X.5 Connector M 5 BN RD BK WH Terminal assignment plug connector RC8 Pin Designation Description U CM Control voltage for switching on and off the guard locking. S.A Emergency stop (channel A) S.A Emergency stop (channel A) O A Safety output channel A, ON en the door is closed and locked. 5 O B Safety output channel B, ON en the door is closed and locked. 6 U A U B 7 O 8 O Power supply, DC V Door monitoring output, ON en door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. 9 S.B Emergency stop (channel B) 0 O Monitoring output DIA, ON en the device is in the fault state. S.B Emergency stop (channel B) Not used RST V Ground Reset input, device is reset if DC V are applied to RST for at least s. See Terminal assignment cable Terminal Designation Description X. to X.7 See X. to X. See X. U A Power supply, DC V (connected internally to X5.6) X5.6 U B Power supply, DC V (connected internally to X.) X.5 and X.6 0 V Ground (connected internally to X5.5) X.7 U CM Control voltage for switching on and off the guard locking. X. to X. Not used X. O A Safety output channel A, ON en the door is closed and locked. X.5 O B Safety output channel B, ON en the door is closed and locked. X.6 RST X5. O X5. O X5. O X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Guard locking monitoring output, ON en the door is closed and locked. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5 and X.6) 5

16 Safety System MGB...AP... Locking sets MGBLAP... (guard locking by solenoid force) with controls or indicators AP Cat. PLe Guard locking with guard lock monitoring in accordance with EN 088 With plug connector Integrated controls and indicators Details Label carrier Devices with label carrier have preformed recesses. The label carrier enclosed can be bonded in this recess (standard dimension.5 x 7 mm). Keyoperated switch form L Form L, 90 angle of rotation with positions. The key latches in both positions, however it can only be removed in position 0. Devices with keyoperated switch have degree of protection IP. Further information Dimension drawings see p. 9 Technical data see p. 8 Accessories and spare parts see p Ordering table Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 05 Incl. label carrier, IP 05 ye 0 Form L 90 Plug connector RC right 05 MGBLHEAPAR05 Incl. label carrier, IP ye 0 Form L 90 Plug connector RC left 05 MGBLHEAPAL05 6

17 Safety System MGB...AP... MGBL... Block and for controls and indicators Plug connector RC UB DC V OV OA Safety OB UA 0V DC V (Aux Pwr) UCM S S S H H Guard locking Reset Monitoring S.A S.B S.B S.A RST O O Terminal assignment plug connector RC8 Pin Designation Description U B Power supply, DC V O O RST Monitoring output DIA, ON en the device is in the fault state. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Reset input, device is reset if DC V are applied to RST for at least s. 5 O B Safety output channel B, ON en the door is closed and locked. 6 0 V Ground 7 O A Safety output channel A, ON en the door is closed and locked. 8 U CM Control voltage for switching on and off the guard locking. 9 0 See Plug connector housing See 9 U A Power supply, DC V MGBAP 7

18 Safety System MGB...AP... Technical data Parameter Value Unit Housing material Dimensions Weight Locking module Handle module Escape release Glass fiber reinforced plastic diecast zinc, nickelplated stainless steel See dimension drawing Ambient temperature at U B = DC V C Degree of protection Cover not populated Cover populated Cover populated with keyoperated switch Safety class Degree of contamination Installation position Locking force F zh in accordance with GSET9 000 N Connection type IP 5 IP 5 IP III Any cable entries M0x.5 or plug connector RC8 Conductor crosssection (rigid/flexible) mm² kg Operating voltage U B (reverse polarity protected, regulated, residual ripple < 5 %) Auxiliary power U A (reverse polarity protected, regulated, residual ripple < 5 %) +0% / 5% (PELV) V DC +0% / 5% (PELV) V DC Current consumption I UB (no load on any ) 80 ma Current consumption with guard locking solenoid I UA (with energized guard locking solenoid and unloaded O... O) 50 ma Additional current consumption for version with controls and indicators in the cover External fuse Safety OA/OB Output voltage U OA / U OB ) max. 0 See system manual Semiconductor, pswitching, short circuitproof, pulsing (pulse duration < 00 µs) ma HIGH U OA / U OB U B V... U B LOW U OA / U OB 0... V DC Switching current per safety output ma Utilization category according to EN IEC Classification acc. to EN IEC Monitoring Output voltage ) Max. load DC V 00 ma Caution: must be protected with a freeeeling diode in case of inductive loads. PDFM pswitching, short circuitproof U A V... U A max. 00 Rated insulation voltage U i 0 V Rated impulse withstand voltage U imp.5 kv Resilience to vibration As per EN IEC EMC protection requirements As per EN IEC Reliability figures according to EN ISO 89 ) Category ma Performance Level PL e PFH d. x 0 9 / h ) Mission time 0 years B 0d ) emergency stop x 0 5 cycles ) Values at a switching current of 50 ma without taking into account the cable lengths. ) The reliability figures apply to the interlocking or the guard locking depending on the version. ) Applying the limit value from EN ISO 89:008, section.5. (MTTF d = max. 00 years) BG certifies a PFH d of max..7 x 0 8. ) Information regarding wearing parts without consideration of fixed failure rates in electronic components. 8

19 Safety System MGB...AP... Dimension drawings MGB...AP without additional controls and indicators Plug connector M CLOSED 06 OPEN 55, 0 MGBAP <5> 0 9, 9,,5 0 55, 0 M0x,5 (x) 0 OPEN 7,5 CLOSED ,, Mx, View of connection side Plug connector RC8 7 M0x,5 (x) 9,5 Mx 89, 7,5 MGB...AP with additional controls and indicators View of connection side 89, 9

20 Safety System MGB...AP... Connection examples Important: The following example is only a simplified representation. Detailed information on the safety system MGB is available in the system manual for the related evaluation module. The system manual is available at Operation on a EUCHNER safety relay ESM with feedback loop and monitored start button V F Entriegeln F F F UA 0V OUT OUT OUT OUT RST OB OA UCM 0V 0VM UB Start KA MGBL..AP.. KB A A S S S S VDC EUCHNER ESMBAxx K + K + A S0 S KA A A KB A A GND Operation on a EUCHNER safety relay ESM with feedback loop and automatic start V F Entriegeln F F F KA KB A UA 0V OUT OUT OUT OUT RST OB OA UCM 0V 0VM UB A S EUCHNER VDC ESMBAxx S S + K K S + MGBL...AP A S0 S KA A A KB A A GND 0

21 Safety System MGB...AR... Complete sets system family MGBAR Interlocking or guard locking with handle module With escape release With buttons and emergency stop With plug connectors MGBAR Interlocking sets MGBL0AR... (without guard locking) 9 without controls and indicators with controls and indicators with controls and indicators 6 Locking sets MGBLAR... (guard locking by spring force) 0 without controls and indicators 0 with control and indicator with controls and indicators with controls and indicators 8 Locking sets MGBLAR... (guard locking by solenoid force) 5 without controls and indicators with controls and indicators 6 with controls and indicators 50 Technical data 5 Dimension drawings 55 Connection examples 56

22 Safety System MGB...AR... Interlocking sets MGBL0AR... without controls or indicators AR Cat. PLe Further information Dimension drawings see p. 55 Technical data see p. 5 Accessories and spare parts see p Interlocking (without guard locking) in accordance with EN 088 Can be connected in series with other AR devices (e. g. CESAR and CETAR) With cable or plug connector Ordering table Modules in the set Ordering data set Interlocking module Version/configuration scheme S H S H S H S H Connection Handle module Escape release Door stop Order no./item 05 A 006 adjustable MGBL0HARR A adjustable MGBL0HEARR Plug connector RC8 B 006 right 099 MGBL0HARAR Plug connector RC8 B 006 left 095 MGBL0HARAL095

23 Safety System MGB...AR... MGBL0... Block A X5.6 X5.5 X. X. X. X.5 X. X.5 B Plug connector RC UB OV IA IB OA OB UA 0V UB OV IA IB OA OB UA 0V DC V Safety inputs Safety DC V (Aux Pwr) DC V Safety inputs Safety DC V (Aux Pwr) Reset Monitoring Reset Monitoring RST O O O RST O O O X.6 X5. X5. X Terminal assignment cable Terminal Designation Description X. to X.7 Not used X. to X. Not used X. U A Power supply for the monitoring, DC V X.5 and X.6 0 V Ground (connected internally to X5.5). X.7 Not used X. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. X. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. X. Not used X. O A ON en the door is closed and the bolt tongue Safety output channel A, is inserted in the interlocking module. X.5 O B ON en the door is closed and the bolt tongue Safety output channel B, is inserted in the interlocking module. X.6 RST X5. O X5. O X5. Not used X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5). X5.6 U B Power supply, DC V Terminal assignment plug connector RC8 Pin Designation Description Not used I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. O A ON en the door is closed and the bolt tongue Safety output channel A, is inserted in the interlocking module. 5 O B ON en the door is closed and the bolt tongue Safety output channel B, is inserted in the interlocking module. 6 U A U B 7 RST 8 O 9 O 0 Not used O Power supply, DC V Reset input, device is reset if DC V are applied to RST for at least s. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the interlocking module. Monitoring output DIA, ON en the device is in the fault state. Door monitoring output, ON en the door is closed. Not used 9 0 V Ground MGBAR

24 Safety System MGB...AR... Interlocking sets MGBL0AR... with controls or indicators AR Cat. PLe Further information Dimension drawings see p. 55 Technical data see p. 5 Accessories and spare parts see p Interlocking (without guard locking) in accordance with EN 088 Can be connected in series with other AR devices (e. g. CESAR and CETAR) With cable Integrated controls and indicators Ordering table for complete sets Modules in the set Ordering data set Version/configuration scheme Interlocking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 098 bu 006 adjustable 0989 MGBL0HARR0989

25 Safety System MGB...AR... MGBL0... Block and for controls and indicators X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X. UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) S S Reset Monitoring RST O O O H H X.6 X5. X5. X5. X. X. Terminal assignment cable Terminal Designation Description X. to X.7 X. to X. See for controls and indicators. X. U A Power supply for the monitoring, DC V X.5 and X.6 0 V Ground (connected internally to X5.5) X.7 Not used X. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. X. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. X. Not used X. O A ON en the door is closed and the bolt tongue Safety output channel A, is inserted in the interlocking module. X.5 O B ON en the door is closed and the bolt tongue Safety output channel B, is inserted in the interlocking module. X.6 RST X5. O X5. O X5. Not used X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the interlocking module. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5) X5.6 U B Power supply, DC V MGBAR 5

26 Safety System MGB...AR... Interlocking sets MGBL0AR... with controls or indicators AR Cat. PLe Details Label carrier Devices with label carrier have preformed recesses. The label carrier enclosed can be bonded in this recess (standard dimension.5 x 7 mm). Further information Dimension drawings see p. 55 Technical data see p. 5 Accessories and spare parts see p Interlocking (without guard locking) in accordance with EN 088 Can be connected in series with other AR devices (e. g. CESAR and CETAR) With cable or plug connector Integrated controls and indicators Ordering table Modules in the set Ordering data set Version/configuration scheme Interlocking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 0606 ye A 006 adjustable MGBL0HARR ye A adjustable 0578 MGBL0HEARR ye bu A adjustable 0900 MGBL0HEARR0900 (Continued on next page) 6

27 Safety System MGB...AR... MGBL0... Ordering table (continued) Modules in the set Ordering data set Version/configuration scheme Interlocking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 0687 Incl. label carrier ye Plug connector RC8 B right 069 MGBL0HEARAR Incl. label carrier ye Plug connector RC8 B left 069 MGBL0HEARAL Incl. label carrier ye Plug connector RC8 B 006 right 0955 MGBL0HARAR0955 MGBAR 0688 Incl. label carrier ye Plug connector RC8 B 006 left 0958 MGBL0HARAL0958 7

28 Safety System MGB...AR... Interlocking sets MGBL0AR... with controls or indicators AR Cat. PLe Block and s for controls and indicators A X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X. X. X. UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) S S H H Reset Monitoring S.A S.B S.B S.A RST O O O X.6 X5. X5. X5. X. X. X. X. B Plug connector RC UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) S S H H Reset Monitoring S.A S.B S.B S.A RST O O

29 Safety System MGB...AR... MGBL0... Terminal assignment cable Terminal Designation Description X. to X.7 See A for controls and indicators. X. to X. X. U A Power supply for the monitoring, DC V X.5 0 V Ground (connected internally to X5.5). X.6 Not used X.7 Not used X. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. X. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. X. Not used X. O A ON en the door is closed and the bolt tongue Safety output channel A, is inserted in the interlocking module. X.5 O B ON en the door is closed and the bolt tongue Safety output channel B, is inserted in the interlocking module. X.6 RST X5. O X5. O X5. Not used X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the interlocking module. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5) X5.6 U B Power supply, DC V Terminal assignment plug connector RC8 Pin Designation Description Not used I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. O A ON en the door is closed and the bolt tongue Safety output channel A, is inserted in the interlocking module. 5 O B ON en the door is closed and the bolt tongue Safety output channel B, is inserted in the interlocking module. 6 U A U B 7 RST 8 O 9 O 0 Power supply, DC V Reset input, device is reset if DC V are applied to RST for at least s. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the interlocking module. Monitoring output DIA, ON en the device is in the fault state. See B Not used V Ground See B for controls and indicators. MGBAR 9

30 Safety System MGB...AR... Locking sets MGBLAR... (guard locking by spring force) without control or indicator AR Cat. PLe Further information Dimension drawings see p. 55 Technical data see p. 5 Accessories and spare parts see p Guard locking with guard lock monitoring in accordance with EN 088 Can be connected in series with other AR devices (e. g. CESAR and CETAR) With cable or plug connector Ordering table Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 00 A 006 adjustable 0578 MGBLHARR A adjustable 0578 MGBLHEARR Plug connector RC8 B 006 right 070 MGBLHARAR Plug connector RC8 B 006 left 07 MGBLHARAL07 0

31 Safety System MGB...AR... MGBL... Block A X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 B Plug connector RC UB OV IA IB OA OB UA 0V UCM UB OV IA IB OA OB UA 0V UCM DC V Safety inputs Safety DC V (Aux Pwr) DC V Safety inputs Safety DC V (Aux Pwr) Guard Guard locking locking Reset Monitoring Reset Monitoring RST O O O O RST O O O O X.6 X5. X5. X5. X Terminal assignment cable Terminal Designation Description X. to X.7 Not used X. to X. Not used X. U A Power supply for the guard locking solenoid and the monitoring, DC V X.5 and X.6 0 V Ground (connected internally to X5.5) X.7 U CM Control voltage for switching on and off the guard locking. X. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. X. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. X. Not used X. O A Safety output channel A, ON en the door is closed and locked. X.5 O B Safety output channel B, ON en the door is closed and locked. X.6 RST X5. O X5. O X5. O X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Guard locking monitoring output, ON en the door is closed and locked. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5) X5.6 U B Power supply, DC V Terminal assignment plug connector RC8 Pin Designation Description U CM Control voltage for switching on and off the guard locking. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. O A Safety output channel A, ON en the door is closed and locked. 5 O B Safety output channel B, ON en the door is closed and locked. 6 U A U B 7 RST 8 O 9 O 0 O O Not used Power supply, DC V Reset input, device is reset if DC V are applied to RST for at least s. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Monitoring output DIA, ON en the device is in the fault state. Guard locking monitoring output, ON en the door is closed and locked. Door monitoring output, ON en the door is closed. Not used 9 0 V Ground MGBAR

32 Safety System MGB...AR... Locking sets MGBLAR... (guard locking by spring force) with one control or indicator AR Cat. PLe Details Degree of protection IP 65 By using special control and indicators, degree of protection IP 65 is achieved. Further information Dimension drawings see p. 55 Technical data see p. 5 Accessories and spare parts see p Guard locking with guard lock monitoring in accordance with EN 088 Can be connected in series with other AR devices (e. g. CESAR and CETAR) With cable or plug connector Integrated controls and indicators Ordering table Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 0780 IP 65 gn A adjustable 078 MGBLHEARAR IP 65 A adjustable 0997 MGBLHEARR Plug connector RC8 B right MGBLHEARR Plug connector RC8 B left 0989 MGBLHEARL0989

33 Safety System MGB...AR... MGBL... Block and s for controls and indicators A B Plug connector RC 8 X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S Guard Guard locking locking Reset Monitoring H Reset Monitoring H RST O O O O RST O O O X.6 X5. X5. X5. X5. X Terminal assignment cable Terminal Designation Description X. to X.7 X. to X. See A for controls and indicators. See A for controls and indicators. X. U A Power supply for the guard locking solenoid and the monitoring, DC V X.5 and X.6 0 V Ground (connected internally to X5.5) X.7 U CM Control voltage for switching on and off the guard locking. X. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. X. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. X. Not used X. O A Safety output channel A, ON en the door is closed and locked. X.5 O B Safety output channel B, ON en the door is closed and locked. X.6 RST X5. O X5. O X5. O X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Guard locking monitoring output, ON en the door is closed and locked. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5) X5.6 U B Power supply, DC V Terminal assignment plug connector RC8 Pin Designation Description U CM Control voltage for switching on and off the guard locking. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. O A Safety output channel A, ON en the door is closed and locked. 5 O B Safety output channel B, ON en the door is closed and locked. 6 U A U B 7 RST 8 O 9 O 0 O Power supply, DC V Reset input, device is reset if DC V are applied to RST for at least s Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module Guard locking monitoring output, ON en the door is closed and locked Monitoring output DIA, ON en the device is in the fault state See B for controls and indicators Not used V Ground See B for controls and indicators MGBAR

34 Safety System MGB...AR... Locking sets MGBLAR... (guard locking by spring force) with controls or indicators AR Cat. PLe Guard locking with guard lock monitoring in accordance with EN 088 Can be connected in series with other AR devices (e. g. CESAR and CETAR) With cable or plug connector Integrated controls and indicators Details Emergency stop with auxiliary contact Additional normally open contact in the emergency stop, e. g. as auxiliary contact for the control system. Label carrier Devices with label carrier have preformed recesses. The label carrier enclosed can be bonded in this recess (standard dimension.5 x 7 mm). Further information Dimension drawings see p. 55 Technical data see p. 5 Accessories and spare parts see p Ordering table Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item A adjustable 0986 MGBLHEARR ye B adjustable 0955 MGBLHEARR Incl. label carrier gn ye B 006 adjustable 0997 MGBLHARR bu C 006 adjustable 0975 MGBLHARR0975 (Continued on next page)

35 Safety System MGB...AR... MGBL... Ordering table (continued) Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 07 ye bu C adjustable 070 MGBLHEARAR070 Incl. label carrier bu C 006 right 5 MGBLHARAR5 6 Incl. label carrier bu C 006 left 7 MGBLHARAL7 MGBAR incl. label carrier, IP incl. label carrier, IP 65 bu bu gn gn Plug connector RC8 D Plug connector RC8 D 006 right 006 left MGBLHARR MGBLHARL

36 Safety System MGB...AR... Locking sets MGBLAR... (guard locking by spring force) with controls or indicators AR Cat. PLe Block and s for controls and indicators A X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X.7 X. UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S H Guard locking Reset Monitoring S.A S.B S.B S.A RST O O O O X.6 X5. X5. X5. X5. X. X. X. X. X.6 B X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X. X.7 UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S Guard locking Reset Monitoring RST O O O O H H X.6 X5. X5. X5. X5. X.6 X. C X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X.7 X. UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S Guard locking Reset Monitoring RST O O O O H H X.6 X5. X5. X5. X5. X. X. D Plug connector RC UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S Guard locking Reset Monitoring RST O O O H H

37 Safety System MGB...AR... MGBL... Terminal assignment cable Terminal Designation Description X. to X.7 X. to X. See s A to C for controls and indicators. See s A to C for controls and indicators. X. U A Power supply for the guard locking solenoid and the monitoring, DC V X.5 and X.6 0 V Ground (connected internally to X5.5). X.7 U CM Control voltage for switching on and off the guard locking. X. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. X. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. X. Not used X. O A Safety output channel A, ON en the door is closed and locked. X.5 O B Safety output channel B, ON en the door is closed and locked. X.6 RST X5. O X5. O X5. O X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Guard locking monitoring output, ON en the door is closed and locked. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5) X5.6 U B Power supply, DC V Terminal assignment plug connector RC8 Pin Designation Description U CM Control voltage for switching on and off the guard locking. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. O A Safety output channel A, ON en the door is closed and locked. 5 O B Safety output channel B, ON en the door is closed and locked. 6 U A U B 7 RST 8 O 9 O 0 O Not used Not used V Ground Power supply, DC V Reset input, device is reset if DC V are applied to RST for at least s. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Monitoring output DIA, ON en the device is in the fault state. Guard locking monitoring output, ON en the door is closed and locked. See D for controls and indicators. MGBAR 7

38 Safety System MGB...AR... Locking sets MGBLAR... (guard locking by spring force) with controls or indicators AR Cat. PLe Guard locking with guard lock monitoring in accordance with EN 088 Can be connected in series with other AR devices (e. g. CESAR and CETAR) With cable or plug connector Integrated controls and indicators Details Emergency stop with auxiliary contact Additional normally open contact in the emergency stop, e. g. as auxiliary contact for the control system. Label carrier Devices with label carrier have preformed recesses. The label carrier enclosed can be bonded in this recess (standard dimension.5 x 7 mm). Keyoperated switch form V or L Form V, 0 angle of rotation with positions. The key latches in position 0. The key can be removed in this position. Form L, 90 angle of rotation with positions. The key latches in both positions, however it can only be removed in position 0. Devices with keyoperated switch have degree of protection IP. Selector switch Selector switch with positions (form V, 90 ). The switch latches in both positions. Machine stop Version as emergency stop but in grey/yellow, e. g. as machine stop. Important: Do not use as emergency stop! Further information Dimension drawings see p. 55 Technical data see p. 5 Accessories and spare parts see p Ordering table Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 058 ye A 006 adjustable 0578 MGBLHARR ye A adjustable MGBLHEARR ye B adjustable 00 MGBLHEARR gn bu A adjustable 077 MGBLHEARAR077 (Continued on next page) 8

39 Safety System MGB...AR... MGBL... Ordering table (continued) Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 070 ye bu B adjustable 070 MGBLHEARR070 6 Incl. label carrier bu B 006 right 7 MGBLHARAR7 8 Incl. label carrier 09 bu 0 Form V 90 B C 006 left adjustable 9 MGBLHARAL9 09 MGBLHEARR09 MGBAR 6 IP ye 0 Form V, 0 C right MGBLHEARAR 06 IP 0 Form L, 90 gn rd D 006 right 07 MGBLHARR07 5 Incl. label carrier gn B 006 right 5 MGBLHARAR5 5 Incl. label carrier gn B 006 left 5 MGBLHARAL5 (Continued on next page) 9

40 Safety System MGB...AR... Locking sets MGBLAR... (guard locking by spring force) with controls or indicators AR Cat. PLe Ordering table (continued) Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 0685 ye Plug connector RC8 E 006 right 06 MGBLHARAR ye Plug connector RC8 E 006 left 06 MGBLHARAL Incl. label carrier ye Plug connector RC8 E right 0689 MGBLHEARAR Incl. label carrier ye Plug connector RC8 E left 0690 MGBLHEARAL Incl. label carrier Plug connector RC8 F 006 right 0870 MGBLHARAR Incl. label carrier Plug connector RC8 F 006 left 087 MGBLHARAL087 0

41 Safety System MGB...AR... MGBL... Block and s for controls and indicators A X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X.7 X. X. X. UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S H H Guard locking Reset Monitoring S.A S.B S.B S.A RST O O O O X.6 X5. X5. X5. X5. X. X. X. X. B X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X.7 X. X. X. UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S H H Reset RST Guard locking Monitoring O O O O S.A S.B S.B S.A MGBAR X.6 X5. X5. X5. X5. X. X. X. X. X.6 C X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X.7 X. X. UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S H Guard locking Reset Monitoring S.A S.B S.B S.A RST O O O O X.6 X5. X5. X5. X5. X. X. X. X. D X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X. X.7 X. UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S S Guard locking Reset Monitoring RST O O O O H H X.6 X5. X5. X5. X5. X. X.

42 Safety System MGB...AR... Locking sets MGBLAR... (guard locking by spring force) with controls or indicators AR Cat. PLe Block and s for controls and indicators E Plug connector RC UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S H H Guard locking Reset Monitoring S.A S.B S.B S.A RST O O F Plug connector RC UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S S Guard locking Reset Monitoring H H H RST O O O O

43 Safety System MGB...AR... MGBL... Terminal assignment cable Terminal Designation Description X. to X.7 X. to X. See s A to D for controls and indicators. See s A to D for controls and indicators. X. U A Power supply for the guard locking solenoid and the monitoring, DC V. X.5 and X.6 0 V Ground (connected internally to X5.5). X.7 U CM Control voltage for switching on and off the guard locking. X. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. X. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. X. Not used X. O A Safety output channel A, ON en the door is closed and locked. X.5 O B Safety output channel B, ON en the door is closed and locked. X.6 RST X5. O X5. O X5. O X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Guard locking monitoring output, ON en the door is closed and locked. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5) X5.6 U B Power supply, DC V Terminal assignment plug connector RC8 Pin Designation Description U CM Control voltage for switching on and off the guard locking. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. O A Safety output channel A, ON en the door is closed and locked. 5 O B Safety output channel B, ON en the door is closed and locked. 6 U A U B 7 RST 8 O 9 O 0 O O Not used V Ground Power supply, DC V Reset input, device is reset if DC V are applied to RST for at least s. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Monitoring output DIA, ON en the device is in the fault state. Guard locking monitoring output, ON en the door is closed and locked. Door monitoring output, ON en the door is closed. See s E and F for controls and indicators. MGBAR

44 Safety System MGB...AR... Locking sets MGBLAR... (guard locking by solenoid force) without control or indicator AR Cat. PLe Further information Dimension drawings see p. 55 Technical data see p. 5 Accessories and spare parts see p Guard locking with guard lock monitoring in accordance with EN 088 Can be connected in series with other AR devices (e. g. CESAR and CETAR) With cable or plug connector Ordering table Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 00 A 006 adjustable MGBLHARR A adjustable MGBLHEARR Plug connector RC8 B 006 right MGBLHARR Plug connector RC8 B 006 left 0978 MGBLHARL0978

45 Safety System MGB...AR... MGBL... Block A X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 B Plug connector RC UB OV IA IB OA OB UA 0V UCM UB OV IA IB OA OB UA 0V UCM DC V Safety inputs Safety DC V (Aux Pwr) DC V Safety inputs Safety DC V (Aux Pwr) Guard Guard locking locking Reset Monitoring Reset Monitoring RST O O O O RST O O O O X.6 X5. X5. X5. X Terminal assignment cable Terminal Designation Description X. to X.7 Not used X. to X. Not used X. U A Power supply for the guard locking solenoid and the monitoring, DC V X.5 and X.6 0 V Ground (connected internally to X5.5) X.7 U CM Control voltage for switching on and off the guard locking. X. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. X. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. X. Not used X. O A Safety output channel A, ON en the door is closed and locked. X.5 O B Safety output channel B, ON en the door is closed and locked. X.6 RST X5. O X5. O X5. O X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Guard locking monitoring output, ON en the door is closed and locked. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5) X5.6 U B Power supply, DC V Terminal assignment plug connector RC8 Pin Designation Description U CM Control voltage for switching on and off the guard locking. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. O A Safety output channel A, ON en the door is closed and locked. 5 O B Safety output channel B, ON en the door is closed and locked. 6 U A U B 7 RST 8 O 9 O 0 O O Not used Power supply, DC V Reset input, device is reset if DC V are applied to RST for at least s. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Monitoring output DIA, ON en the device is in the fault state. Guard locking monitoring output, ON en the door is closed and locked. Door monitoring output, ON en the door is closed. Not used 9 0 V Ground MGBAR 5

46 Safety System MGB...AR... Locking sets MGBLAR... (guard locking by solenoid force) with controls or indicators AR Cat. PLe Details Label carrier Devices with label carrier have preformed recesses. The label carrier enclosed can be bonded in this recess (standard dimension.5 x 7 mm). Further information Dimension drawings see p. 55 Technical data see p. 5 Accessories and spare parts see p Guard locking with guard lock monitoring in accordance with EN 088 Can be connected in series with other AR devices (e. g. CESAR and CETAR) With cable or plug connector Integrated controls and indicators Ordering table Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 09 ye A adjustable 0956 MGBLHEARR ye B adjustable 0906 MGBLHEARR Incl. label carrier bu B 006 right 9 MGBLHARR9 0 Incl. label carrier bu B 006 left MGBLHARL (Continued on next page) 6

47 Safety System MGB...AR... MGBL... Ordering table (continued) Modules in the set Ordering data set Version/configuration scheme Evaluation module S H S H S H S H Connection Handle module MGBAR Escape release Door stop Order no./item rd gn B 006 right 97 MGBLHARAR97 6 rd gn B 006 left 98 MGBLHARAL98 7

48 Safety System MGB...AR... Locking sets MGBLAR... (guard locking by solenoid force) with controls or indicators AR Cat. PLe Block and s for controls and indicators A X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X. X.7 UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S Guard locking Reset Monitoring RST O O O O H H X.6 X5. X5. X5. X5. X.6 X. B X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X.7 X. UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S Guard locking Reset Monitoring RST O O O O H H X.6 X5. X5. X5. X5. X. X. 8

49 Safety System MGB...AR... MGBL... Terminal assignment cable Terminal Designation Description X. to X.7 X. to X. See s A and B for controls and indicators. See s A and B for controls and indicators. X. U A Power supply for the guard locking solenoid and the monitoring, DC V X.5 and X.6 0 V Ground (connected internally to X5.5) X.7 U CM Control voltage for switching on and off the guard locking. X. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. X. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. X. Not used X. O A Safety output channel A, ON en the door is closed and locked. X.5 O B Safety output channel B, ON en the door is closed and locked. X.6 RST X5. O X5. O X5. O X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Guard locking monitoring output, ON en the door is closed and locked. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5) X5.6 U B Power supply, DC V MGBAR 9

50 Safety System MGB...AR... Locking sets MGBLAR... (guard locking by solenoid force) with controls or indicators AR Cat. PLe Guard locking with guard lock monitoring in accordance with EN 088 Can be connected in series with other AR devices (e. g. CESAR and CETAR) With cable or plug connector Integrated controls and indicators Details Emergency stop with auxiliary contact Additional normally open contact in the emergency stop, e. g. as auxiliary contact for the control system. Label carrier Devices with label carrier have preformed recesses. The label carrier enclosed can be bonded in this recess (standard dimension.5 x 7 mm). Further information Dimension drawings see p. 55 Technical data see p. 5 Accessories and spare parts see p Ordering table Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item ye A adjustable 0988 MGBLHEARR ye B 006 adjustable MGBLHARR ye B adjustable MGBLHEARR gn B adjustable MGBLHEARR09956 (Continued on next page) 50

51 Safety System MGB...AR... MGBL... Ordering table (continued) Modules in the set Ordering data set Version/configuration scheme Locking module S H S H S H S H Connection Handle module Escape release Door stop Order no./item 0 Incl. label carrier bu A 006 right MGBLHARAR Incl. label carrier bu A 006 left MGBLHARAL 067 Incl. label carrier ye Plug connector RC8 C right 00 MGBLHEARR00 MGBAR 068 Incl. label carrier ye Plug connector RC8 C left 0 MGBLHEARL ye Plug connector RC8 D 006 right 065 MGBLHARAR ye Plug connector RC8 D 006 left 066 MGBLHARAL066 5

52 Safety System MGB...AR... Locking sets MGBLAR... (guard locking by solenoid force) with controls or indicators AR Cat. PLe Block and s for controls and indicators A X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X.7 X. X. X. UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S H H Guard locking Reset Monitoring S.A S.B S.B S.A RST O O O O X.6 X5. X5. X5. X5. X. X. X. X. X.6 B X5.6 X5.5 X. X. X. X.5 X. X.5 X.7 X.7 X. X. X. UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S H H Guard locking Reset Monitoring S.A S.B S.B S.A RST O O O O X.6 X5. X5. X5. X5. X. X. X. X. C Plug connector RC UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S H H Guard locking Reset Monitoring S.A S.B S.B S.A RST O O O D Plug connector RC UB DC V OV IA Safety inputs IB OA Safety OB UA 0V DC V (Aux Pwr) UCM S S H H Guard locking Reset Monitoring S.A S.B S.B S.A RST O O

53 Safety System MGB...AR... MGBL... Terminal assignment cable Terminal Designation Description X. to X.7 X. to X. See s A and B for controls and indicators. See s A and B for controls and indicators. X. U A Power supply for the guard locking solenoid and the monitoring, DC V X.5 and X.6 0 V Ground (connected internally to X5.5) X.7 U CM Control voltage for switching on and off the guard locking. X. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. X. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. X. Not used X. O A Safety output channel A, ON en the door is closed and locked. X.5 O B Safety output channel B, ON en the door is closed and locked. X.6 RST X5. O X5. O X5. O X5. O Reset input, device is reset if DC V are applied to RST for at least s. Door monitoring output, ON en the door is closed. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Guard locking monitoring output, ON en the door is closed and locked. Monitoring output DIA, ON en the device is in the fault state. X5.5 0 V Ground (connected internally to X.5) X5.6 U B Power supply, DC V Terminal assignment plug connector RC8 according to Pin Designation Description U CM Control voltage for switching on and off the guard locking. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. O A Safety output channel A, ON en the door is closed and locked. 5 O B Safety output channel B, ON en the door is closed and locked. 6 U A U B 7 RST 8 O 9 O 0 O Power supply, DC V Terminal assignment plug connector RC8 according to D Pin Designation Description Reset input, device is reset if DC V are applied to RST for at least s. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Guard locking monitoring output, ON en the door is closed and locked. Monitoring output DIA, ON en the device is in the fault state. to 8 See C for controls and indicators. 9 0 V Ground U CM Control voltage for switching on and off the guard locking. I A in separate operation. In case of switch chains, Enable input for channel A, connect to DC V connect output signal O A from previous device. I B in separate operation. In case of switch chains, Enable input for channel B, connect to DC V connect output signal O B from previous device. O A Safety output channel A, ON en the door is closed and locked. 5 O B Safety output channel B, ON en the door is closed and locked. MGBAR 6 U A U B 7 RST 8 O 9 O 0 to Not used to V Ground Power supply, DC V Reset input, device is reset if DC V are applied to RST for at least s. Bolt tongue monitoring output, ON en the door is closed and the bolt tongue is inserted in the locking module. Monitoring output DIA, ON en the device is in the fault state. See D for controls and indicators. See D for controls and indicators. 5

54 Safety System MGB...AR... Technical data Parameter Value Unit Housing material Dimensions Weight Locking module Handle module Escape release Glass fiber reinforced plastic diecast zinc, nickelplated Stainless steel See dimension drawing Ambient temperature at U B = DC V C Degree of protection Cover not populated Cover populated Cover populated with IP 65 buttons/indicators Cover populated with keyoperated switch Safety class Degree of contamination Installation position Locking force 000 N Connection type IP 5 IP 5 IP 65 IP III Any cable entries M0x.5 or plug connector RC8 Conductor crosssection (rigid/flexible) mm² kg Operating voltage U B (reverse polarity protected, regulated, residual ripple < 5 %) Auxiliary power U A (reverse polarity protected, regulated, residual ripple < 5 %) +0% / 5% (PELV) V DC +0% / 5% (PELV) V DC Current consumption I UB (no load on any ) 80 ma Current consumption with guard locking solenoid I UA (with energized guard locking solenoid and unloaded O... O) 50 ma Additional current consumption for version with controls and indicators in the cover External fuse Safety OA/OB Output voltage U OA / U OB ) max. 0 See system manual Semiconductor, pswitching, short circuitproof, pulsing (pulse duration < 900 µs) ma HIGH U OA / U OB U B V... U B LOW U OA / U OB 0... V DC Switching current per safety output ma Utilization category according to EN IEC Classification acc. to EN IEC Monitoring Output voltage ) Max. load DC V 00 ma Caution: must be protected with a freeeeling diode in case of inductive loads. PDFM pswitching, short circuitproof U A V... U A max. 00 Rated insulation voltage U i 0 V Rated impulse withstand voltage U imp.5 kv Resilience to vibration As per EN IEC EMC protection requirements As per EN IEC Reliability figures according to EN ISO 89 ) Category ma Performance Level PL e PFH d. x 0 9 / h ) Mission time 0 years B 0d ) emergency stop x 0 5 cycles ) Values at a switching current of 50 ma without taking into account the cable lengths. ) The reliability figures apply to the interlocking or the guard locking depending on the version. ) Applying the limit value from EN ISO 89:008, section.5. (MTTF d = max. 00 years) BG certifies a PFH d of max..7 x 0 8. ) Information regarding wearing parts without consideration of fixed failure rates in electronic components. 5

55 Safety System MGB...AR... Dimension drawings MGB...AR without additional controls and indicators Plug connector RC8 CLOSED MGBAR <5> 0 9, 9,,5 0 55, 0 M0x,5 (x) 0 OPEN CLOSED 7, OPEN 7,5 55, 0, View of connection side , 9,5 Mx 7 M0x,5 (x) 89, MGB...AR with additional controls and indicators 89, 55

56 Safety System MGB...AR... Connection examples Important: The following examples are only a simplified representation. Detailed information on the safety system MGB is available in the system manual for the related evaluation module. The system manual is available at Separate operation on a EUCHNER safety relay ESM with feedback loop and monitored start button V F Entriegeln F F F UA 0V OUT OUT OUT OUT RST OB OA IB IA UCM 0V 0VM UB Start KA MGBL..AR.. KB A A S S S S VDC EUCHNER ESMBAxx K + K + A S0 S KA A A KB A A GND Separate operation on a EUCHNER safety relay ESM with feedback loop and automatic start V F Entriegeln F F F KA KB A UA 0V OUT OUT OUT OUT RST OB OA IB IA UCM 0V 0VM UB A S EUCHNER VDC ESMBAxx S S + K K S + MGBL...AR A S0 S KA A A KB A A GND 56

57 Safety System MGB...AR... Operation of an AR switch chain on an EUCHNER safety relay ESM with automatic start, without feedback loop DC V F F F F X5.6 X5.5 X5. X5. X5. X5. X.6 X.5 X. X. X. X. X.7 X.6 X.5 X. X5.6 X5.5 X5. X5. X5. X5. X.6 X.5 X. X. X. X. X.7 X.6 X.5 X. X5.6 X5.5 X5. X5. X5. X5. X.6 X.5 X. X. X. X. X.7 X.6 X.5 X. UB 0V O O O O RST OB OA NC IB IA UCM NC 0VM UA UB 0V O O O O RST OB OA NC IB IA UCM NC 0VM UA UB 0V O O O O RST OB OA NC IB IA UCM NC 0VM UA MGBLAR... # MGBLAR... # MGBLAR... # A F5 F6 A S S S S VDC EUCHNER ESMBAxx K + K + A S0 S GND K5 K6 MGBAR Important: In accordance with the risk analysis, the application must be evaluated using a feedback loop (not shown here). 57

58 Safety System MGB...AR... 58

59 Accessories and Spare Parts MGB...AR.../AP... Accessories and spare parts for all MGB families Plug connectors and cables Mounting plates Extended axes Handle module MGBH Escape release MGBE... Mounting plates for modules MGB...AR and MGB...AP 65 Plug connectors/ connection cables 67 Control module MGBC Scope of delivery, spare parts and accessories 68 Dimension drawing and configuration example 69 Overview controls and indicators 70 Combination options 7 Technical data 7 59

60 Accessories and Spare Parts MGB...AR.../AP... Handle module MGBH... Intelligent bolt tongue with transponder Foldout lockout mechanism Door handle Handle module MGBH... with foldout lockout mechanism Dimension drawing ( shows door hinged on the right) CLOSED Lockout mechanism OPEN 55, 0 Bolt tongue The bolt tongue is reliably detected by transponder as soon as it is inserted in the evaluation module. Lockout mechanism (foldout) For cleaning and service on the machine the bolt tongue can be locked with max. padlocks. The lockout mechanism is simply folded out and prevents the operation of the handle. Door handle The MGB has a robust door handle that can be rotated in 90 steps to suit all installations. The actuating direction can be changed very easily for doors hinged on the left or right M0x,5 (x) 89, Scope of delivery: Door handle Locking pins for housing cover and handle adjustment Lockout mechanism Bolt tongue Ordering table Series Version Order no./item MGBH... Handle module with foldout lockout mechanism, black housing with red cover 006 MGBHAAAR006 60

61 Accessories and Spare Parts MGB...AR.../AP... Handle module MGBH... Intelligent bolt tongue with transponder Foldout lockout mechanism (as on standard version) Second automatically extending lockout mechanism Door handle Handle module MGBH... with automatically extending lockout mechanism Dimension drawing ( shows door hinged on the right) Lockout mechanism automatically extending CLOSED Lockout mechanism OPEN 55, 0 7,5 Bolt tongue The bolt tongue is reliably detected by transponder as soon as it is inserted in the evaluation module. Lockout mechanism (automatically extending and foldout) For cleaning and service on the machine the bolt tongue can be locked with max. padlocks. The lockout mechanism extends automatically on the actuation of the handle and prevents the operation of the handle in the safe state. In addition, the foldout lockout mechanism can be used M0x,5 (x) 89,,6,5 Door handle The MGB has a robust door handle that can be rotated in 90 steps to suit all installations. The actuating direction can be changed very easily for doors hinged on the left or right. Scope of delivery: Door handle Locking pins for housing cover and handle adjustment Lockout mechanism Bolt tongue Ordering table Series Version Order no./item MGBH... Handle module with foldout and also second automatically extending lockout mechanism, black housing with red cover 57 MGBHAAAR57 6

62 Accessories and Spare Parts MGB...AR.../AP... Escape release module MGBE... Door handle red Escape release module MGBE... Dimension drawing ( shows door hinged on the right) CLOSED 06 89, OPEN Escape release The safety system MGB can be complemented by an escape release module. The escape release enables people locked in to open the locked safety guard from inside the danger area. It is only necessary to actuate the door handle. The actuating direction automatically adapts to the actuating direction of the handle module and does not need to be changed. 9 9, 0 55, 0,5 0 Extended actuation axis Optionally a 50 mm long actuation axis (instead of 0 mm) can be ordered for thicker doors. The axis can be shortened to the required dimension. 5 7 M0x,5 (x) 89, 5 Scope of delivery: Door handle Setscrew Cover Protective sleeve 5 Actuation axis, 0 mm long, square drive 8x8 mm Ordering table Series / designation Version Order no./item MGBE... Escape release With red handle 0065 MGBEA0065 Extended actuation axis 50 mm long, square drive 8 x 8 mm

63 Accessories and Spare Parts MGB...AR.../AP... 6

64 Accessories and Spare Parts MGB...AR.../AP... Mounting plates for modules MGB...AR... and MGB...AP... Easy and quick mounting (only two screws required) Quicker module replacement Robust stainless steel plate Suitable for doors hinged on the right or left Mounting plate for evaluation module 5 0,5 Mounting plate for evaluation module Suitable for all interlocking or locking modules in the system families AR and AP. screws are sufficient for fastening the mounting plates. Important: Only use if the handle module is also fastened to a mounting plate. 0 0 M6 (x) 6,5 6 86,05 7,5 5 7, Mounting plate for handle modules Mounting plate for handle module Suitable for all MGB handle modules. screws are sufficient for fastening the mounting plates. Important: Only use if the evaluation module is also fastened to a mounting plate. 70 7,5 5 7,5 6,5 M6 (x) 7,5,5 6 89, ,5 Ordering table Series / designation Version Order no./item Mounting plate for evaluation module Mounting plate for handle module Mounting plate for escape release Mounting plate for evaluation modulecontrol module combination Suitable for all MGBL.AR... and MGBL.AP... Suitable for all MGB handle modules Suitable for all MGB escape releases Suitable for all MGBL.AR... and MGBL.AP... in combination with a control module MGBC MGBA MOUNTING PLATE L MGBA MOUNTING PLATE H MGBA MOUNTING PLATE E MGBA MOUNTING PLATE LC007 6

65 Accessories and Spare Parts MGB...AR.../AP... Mounting plate for escape release Mounting plate for escape release Suitable for all MGB escape releases. screws are sufficient for fastening the mounting plates. Important: Pay attention to length of the escape release axis! You may need a longer axis (order no. 0676, see page 6). 7,5 9,5 86,5 M6 (x) 7, ,5 89, ,5,5 8 0,5 Mounting plate for evaluation modulecontrol module combination Mounting plate for evaluation modulecontrol module combination Suitable for all MGB combinations, comprising an evaluation module and a control module. Important: Only use if the handle module is also fastened to a mounting plate. 0,5 0 AA : 9 5 0,5 5,9 85 M6 (x) A A 6 86,05 58, ,6 (x)

66 Accessories and Spare Parts MGB...AR.../AP... Plug connector RC8 optional Halogenfree cable optional Female plug RC8 with cable 8pin + PE Crimp contacts With 6 crimp pins for wire crosssection mm² and pins for wire crosssection mm² for control of the guard locking solenoid. (optional) sleeve PUR, color black, wire crosssection 0.5 mm² or.0 mm². Depending on the cable version, either colorcoded or with separately numbered, black cores. Dimension drawing 59 Inserted 5 M0x,5 Ø With screen bonding clamp halogenfree (optional) sleeve PUR, color black, halogenfree, siliconefree. Reduction of toxic gases and smoke in case of fire. Wire crosssection 0.5 mm² or.0 mm². Cores colorcoded. SW0 5 6 View of connection side, socket 7 Ordering table Designation Version Order no./item Plug connector RC8 8pin + PE EFC85 Female plug (Crimp contacts included) Replacement pin crimp contacts Wire crosssection 6 x mm x 0.75 mm RC8EFC Pin crimp contact RCMC85 Connection cables RC8 Female plug RC8 with cable 8pin + PE Female plug RC8 with cable halogenfree 8pin + PE Dimension drawing 78 Inserted 7 SW0 Ø,6 ±0, Ø6 5 With screen bonding clamp View of connection side, socket Inserted 85, ±0, 5 With screen bonding clamp View of connection side, socket 8 9 Assignment connection cable RC8 Pin Core color Wire crosssection [mm] Pin Core color Wire crosssection [mm] VT 0.5 BK 0.5 RD 0.5 GN/YE.0 GY 0.5 PK 0.5 RD/BU 0.5 BN/GY GN BN/YE BU.0 6 BN/GN GY/PK WH GN/WH YE YE/WH BN.0 0 GY/WH

67 Accessories and Spare Parts MGB...AR.../AP... Ordering table Designation length [m] Order no./item RC8EF,5MC RC8EFMC RC8EF6MC Female plug RC8 RC8EF8MC85 with cable PUR pin + PE, RC8EF0MC85 Cores colorcoded RC8EF5MC RC8EF0MC RC8EF5MC RC8EF0MC CMF9PU0,5MA00 00 CMF9PU0,0MA00 Female plug RC with cable PUR CMF9PU06,0MA00 9pole, 00 0 Cores numbered, black, CMF9PU0,0MA00 Numbering as per the pin number 005 Core crosssection as for connection cable above 5 CMF9PU5,0MA CMF9PU0,0MA CMF9PU5,0MA RC8EF,5MFC RC8EFMFC RC8EF6MFC85 Plug connector RC8 with cable halogenfree 8pin + PE, Cores colorcoded RC8EF8MFC RC8EF0MFC RC8EF5MFC RC8EF0MFC RC8EF5MFC85 67

68 Accessories and Spare Parts MGB...AR.../AP... Expand your options the control module for the MGB Space for up to 6 controls and indicators Ideal expansion solution for the MGB system A large amount of design flexibility In the control module it is possible to integrate controls such as buttons, emergency stop, keyoperated switches or even indicators as required. In this way a complete functional control panel can be built up. Even the MGB basic system comprising handle module and interlocking/locking module includes numerous functions. And if requirements grow, the MGB system simply grows with them with the aid of the control module. Furthermore, the control module forms an attractive unit together with the MGB. An elegant alternative to the grey switch boxes that were common in the past. Your advantages Simple expansion of the MGB system Flexible configuration with standard components Attractive solution from one mold Functional unit, all control functions in one place Alternative to previous control terminals (Configuration example) Scope of delivery, spare parts and accessories Scope of delivery Designation Description Control module MGBC... Empty housing incl. cover and dummy plugs 099 MGBC000000A099 Connection set Spare parts and accessories Designation Printed circuit board with plugin spring terminals Preassembled wires and cable ties Description Order no. Item MGBALPSET09858 Blind plug 0968 MPAB Cover for indicators (without LED holder) Pushbutton (without switching element) Emergency stop (without switching element) Selector switch (without switching element) Keyoperated switch (without switching element) Transparent (rd) red () ite (ye) yellow Transparent (bu) blue () ite (ye) yellow (gn) green (rd) red Order no Item MPALR0RD00050 MPALR0WH00095 MPALR0YE0005 MPAPRTBUA057 MPAPRTWHA059 MPAPRTYEA058 MPAPRTGNA0 MPAPRTRDA0 Latching, turntoreset 095 MPAERD00A095 positions, latching in positions 095 MPASRR00A095 Incl. keys positions; key removable in each position 095 MPAKRR00A095 Tag holder Incl. labeling plate 0959 MPAH Connection set housing sleeves for M0x.5 gland 095 MGBA HOUSING SLEEVE 095 Switching element with LED holder Expandable with LED positively driven NC contacts, NO contact NO contact MPACGM MPACGU LED holder 0958 MPACCH LED LED, ite 0957 MPACLCWH

69 Accessories and Spare Parts MGB...AR.../AP... Dimension drawing and configuration example Bedienmodul Gehäuse (MGBC...) BestNr. 099 Inklusive: Stück Leergehäuse Stück Deckel Stück Blindverschraubung Control Module Housing (MGBC...) OrderNo. 099 Including: pcs. empty housing pcs. top cover pcs. dummy plug Beispielbestückung Configuration Example (z.b. Best.Nr. / e.g. Order no MGBCELLPPK06795) S S S AnschlussSet BestNr Inklusive: Stück Leiterplatte mit steckbaren Federzugklemmen Stück Befestigungsschrauben für Leiterplatte 7 Stück Litzen kpl. 0, mm² rot 7 Stück Litzen kpl. 0, mm² blau 6 Stück Litzen kpl. 0, mm² schwarz 6 Stück Kabelbinder Connection Kit OrderNo Including: pcs. circuit board with plugin spring terminals pcs. screws for circuit board 7 pcs. strands complete, 0. mm² red 7 pcs. strands complete, 0. mm² blue 6 pcs. strands complete, 0. mm² black 6 pcs. cable straps 5, 5 Position S S S S S5 S6 S Ausführung/Version NotHaltTaster Emergencystop Leuchtvorsatzrot LEDred Leuchtvorsatzgrün LEDgreen Taster beleuchtetweiss Pushbutton illuminatedite Taster beleuchtetweiss Pushbutton illuminatedite Schlüsselschalter Keyoperated switch 5 S5 S6 h, mm 0 mm, mm 0 7,5 60 M0x,5 (x) h ,75,5 6 Unterteil Gehäuse 099 (offen) Bottom of housing 099 (open) X.5 : Bedien / Anzeigeelement Controls / indicators X Zuleitung Supply Leiterplatte mit Anschlussklemmen Circuit board with terminal clamps

70 Accessories and Spare Parts MGB...AR.../AP... Overview controls and indicators (bu) 059 () 058 (ye) 0 (gn) 0 (rd) 05 (ye) 050 (rd) 095 () a b c d e f 0959 Deckel Bedienmodul Operating module cover Farbmarkierung beachten! Note colour coding! a b c Controls/indicators a Blind plug b Selector switch, positions, latching c Emergency stop, turntoreset button d Keyoperated switch, positions, latching (key removable in both positions) e Pushbutton, different colors, illumination with 0957 f Cover for indicators, different colors, illumination with 0957 Tag holder including labeling plate Knurled nut (included with item ) Switching element/led holder a LED holder b Switching element, positively driven NC contacts, NO contact c Switching element, NO contact 5 LED, ite 70

71 Accessories and Spare Parts MGB...AR.../AP... Combination options Switching element Order no Switching element Order no LED holder Order no LED Order no x Emergency stop Order no Latching with turntoreset 0 Keyoperated switch ( positions) Order No. 095 Incl. keys Key removable in both positions ) 0 Selector switch ( positions) Order no. 095 Pushbutton (illuminated) Order no. 059 () Order no. 058 (ye) Order no. 057 (bu) Order no. 0 (gn) Order no. 0 (rd) Cover for indicators Order no. 055 () Order no. 05 (ye) Order no. 050 (rd) Tag holder Order No Blind plug Order no x = Optional = Not combinable = Combinable ) Not in combination with 0957 (LED) 7

72 Accessories and Spare Parts MGB...AR.../AP... Technical data Empty housing Parameter Housing material Value Reinforced thermoplastic Ambient temperature C Type of protection according to EN 6059 IP 5 Degree of contamination / material group External connection Internal connection (plugin spring terminals) Controls Parameter Mech. life Pushbutton Emergency stop Selector switch Keyoperated switch (industrial) x cable M0x mm Value x0 6 5x0 x0 5 x0 Ambient temperature C Type of protection according to EN 6059 Switching elements, LED Parameter Life at 0 ma/ V DC...GU......GM... IP 5 (installed) Value x0 6 5x0 Ambient temperature C Operating voltage Switching elements LED Operating current Switching elements LED Breaking capacity max. Connection type Contact material Shock resistance according to IEC Vibration resistance IEC Positively driven...gm V V ma max. 0 ma permissible 50 mw Connector.8 x 0.8 mm Au 5 g 5 g ( Hz) according to IEC (positively driven NC contact) 7

73 Safety System MGB...PN... Complete sets system family MGBPN Profinet and Profisafe With buttons and emergency stop With plug connectors With mounting plates MGBPN Locking sets MGBLPN... (guard locking by spring force) 7 75 with controls and indicators 7 Locking sets MGBLPN... (guard locking by solenoid force) with controls and indicators 76 PROFINET data bytes 78 Assignment of the terminal plugs 79 Technical data 80 Dimension drawing 8 7

74 Safety System MGB...PN... Locking sets MGBL...PN... (guard locking by spring force) with controls or indicators Cat. PLe * Details Profinet connection Connection via plug connector according to IEC 60767, variant (AIDA standard) Profinet RT switch Pointtopoint topology network structure due to integrated RT switch. Further information Dimension drawings see p. 8 Technical data see p. 80 Accessories and spare parts see p Guard locking with guard lock monitoring in accordance with EN 088 Integrated controls and indicators Preassembled on mounting plates Integrated Profinet RT switch Flexible usage as interlocking or guard locking By means of the corresponding evaluation of the safe device data by the control system, usage can be either as interlocking or guard locking (with or without monitoring). Ordering table Modules in the set Ordering data set Evaluation module and bus module Version/configuration scheme Order no. module combination Controls and indicators Handle module Escape release Door stop Order no./item 079 S S S S 8 9 S S8 S Preassembled on mounting plate right 069 MGBLHBPNAR069 Preassembled on mounting plate, incl. label carrier 070 ye S S S S 8 9 S S8 S9 06 Preassembled on mounting plate left 068 MGBLHBPNAL068 Preassembled on mounting plate, incl. label carrier ye * UL approval pending 7

75 Safety System MGB...PN... MGBL... System components and spare parts c a b d c a b c a b Ordering table for system components and spare parts Note: It is only possible to order spare parts that are given in the following ordering table with an order number. Item Designation Use/description Order no. / item System unit MGBLB... (guard locking by spring force) comprising: For doors hinged on the left For doors hinged on the right 070 MGBLBPNAL MGBLBPNAR079 a Evaluation module b Bus module c Mounting plate For system unit MGBL... Handle module MGBH... comprising: For doors hinged on the left For doors hinged on the right 007 MGBA MOUNTING PLATE LC MGBHAAAL MGBHAAAR0609 MGBPN a Handle module b Door handle Color silver c Mounting plate For handle module MGBH... Escape release MGBE... comprising: 099 MGBA MOUNTING PLATE H MGBEA0605 a Escape release b Escaperelease shaft Standard length 8 mm (square 8x8 mm + sleeve) Replacement shaft for item b Length 50 mm (square 8x8 mm + sleeve) c Door handle Color red d Mounting plate For escape release MGBE MGBA MOUNTING PLATE E099 75

76 Safety System MGB...PN... Locking sets MGBL...PN... (guard locking by solenoid force) with controls or indicators Cat. PLe * Details Profinet connection Connection via plug connector according to IEC 60767, variant (AIDA standard) Profinet RT switch Pointtopoint topology network structure due to integrated RT switch. Further information Dimension drawings see p. 8 Technical data see p. 80 Accessories and spare parts see p Guard locking with guard lock monitoring in accordance with EN 088 Integrated controls and indicators Preassembled on mounting plates Integrated Profinet RT switch Flexible usage as interlocking or guard locking By means of the corresponding evaluation of the safe device data by the control system, usage can be either as interlocking or guard locking (with or without monitoring). Ordering table Modules in the set Ordering data set Evaluation module and bus module Version/configuration scheme Order no. module combination Controls and indicators Handle module Escape release Door stop Order no./item 000 S S S S 8 9 S S8 S right 000 MGBLHBPNAR069 Preassembled on mounting plate, incl. label carrier 000 ye S S S S 8 9 S S8 S9 06 left 0000 MGBLHBPNAL068 Preassembled on mounting plate, incl. label carrier ye * UL approval pending 76

77 Safety System MGB...PN... MGBL... System components and spare parts c a b d c a b c a b Ordering table for system components and spare parts Note: It is only possible to order spare parts that are given in the following ordering table with an order number. Item Designation Use/description Order no. / item System unit MGBLB... (guard locking by solenoid force) comprising: For doors hinged on the left For doors hinged on the right 000 MGBLBPNAL MGBLBPNAR000 a Evaluation module b Bus module c Mounting plate For system unit MGBL... Handle module MGBH... comprising: For doors hinged on the left For doors hinged on the right 007 MGBA MOUNTING PLATE LC MGBHAAAL MGBHAAAR0609 MGBPN a Handle module b Door handle Color silver c Mounting plate For handle module MGBH... Escape release MGBE... comprising: 099 MGBA MOUNTING PLATE H MGBEA0605 a Escape release b Escaperelease shaft Standard length 8 mm (square + sleeve) Replacement shaft for item b Length 50 mm (square 8x8 mm + sleeve) c Door handle Color red d Mounting plate For escape release MGBE MGBA MOUNTING PLATE E099 77

78 Safety System MGB...PN... PROFINET data bytes You will require the corresponding GSD file in GSDML format in order to integrate the MGB system: GSDMLVx.xEUCHNERMGB_006YYYYMMDD.xml You can find the GSD file in the download area at Prior to commissioning, the GSD file must be imported into the configuration software of the control system (see manual for your control system). PROFINET data bytes (unsafe input/output area) Profinet RT modules bytes IO: Assignment in the input area of the bus master: Assignment in output area of the bus master: Byte n+0 I8 I7 I6 I5 I I I I Byte n+ I6 I5 I I I I I0 I9 Byte n+0 O8 O7 O6 O5 O O O O Byte n+ O6 O5 O O O O O0 O9 I: n.c. I: n.c. I: n.c. I: n.c. I5: n.c. I6: n.c. I7: n.c. I8: Button S8 O: n.c. O: n.c. O: n.c. O: n.c. O5: n.c. O6: n.c. O7: n.c. O8: LED S8 I9: Button S9 I0: n.c. I: n.c. I: n.c. I: n.c I: n.c. I5: n.c. I6: n.c O9: LED S9 O0: n.c. O: LED S O: n.c. O: n.c O: n.c. O5: n.c. O6: Guard locking solenoid control voltage on (function identical to bit SO, but control not via PROFIsafe) Byte n+ I I I I I0 I9 I8 I7 Byte n+ O O O O O0 O9 O8 O7 I7: Device diagnosis (PROFIsafe error #7): message present. Diagnostic code: see table of devicespecific messages. I8: Device diagnosis, devicespecific message 7() "Plausibility check found an error (e.g. escape release actuated)" I9: Device diagnosis, devicespecific message 7() or 7() "Error in emergency stop" I0: Device diagnosis, devicespecific message 7() or 7() "Error in enabling switch" I: Device diagnosis, devicespecific message 7(6) or 7(6) "Error in operating mode selector switch" I: n.c. I: n.c. I: Mechanical life > million operating cycles O7: Device diagnosis: acknowledge message, acknowledgment of I9, I0 or I I7 is also acknowledged if only one message is present O8: Trigger MGB locking module reset: acknowledge message, acknowledgement of I8. I7 is also acknowledged if only one message is present. O9: n.c. O0: n.c. O: n.c. O: n.c. O: n.c. O: n.c. 78

79 Safety System MGB...PN... PROFIsafe data bytes (safe input/output area) Profisafe assignment in the output area of the bus master: Profisafe assignment in the input area of the bus master: Byte n+0 SO8 SO7 SO6 SO5 SO SO SO SO Byte n+ SO6 SO5 SO SO SO SO SO0 SO9 Byte n+0 SI8 SI7 SI6 SI5 SI SI SI SI Byte n+ SI6 SI5 SI SI SI SI SI0 SI9 Byte n+ Profisafe internal (control byte) Byte n+ Profisafe internal (control byte) Byte n+ Profisafe internal (serial no.) Byte n+ Profisafe internal (serial no.) Byte n+ Profisafe internal (CRC) Byte n+ Profisafe internal (CRC) Byte n+5 Profisafe internal (CRC) Byte n+5 Profisafe internal (CRC) SO: SO: SO: SO: SO5: SO6: SO7: SO8: Guard locking solenoid control voltage on (function identical to bit O6 => but with control via PROFIsafe) n.c n.c n.c n.c n.c n.c n.c SI: Emergency stop S7 SI: n.c. SI: Door position (T) SI: Bolt position (R) SI5: Guard locking (Z) SI6: n.c. SI7: n.c. SI8: n.c. SO9: n.c SI9: SK (T AND R) for compatibility with TZ SO0: SO: SO: SO: SO: SO6: n.c n.c n.c n.c n.c n.c SI0: ÜK (T AND R AND Z) for compatibility with TZ SI: SI: SI: SI: SI6: n.c n.c n.c n.c n.c. MGBPN Assignment of the terminal plugs Pin Description X. L operating voltage DC V X. N operating voltage 0 V X. L auxiliary power* DC V X. N auxiliary power* 0 V X.5 Function earth * The auxiliary power is not required for the MGB system X: For looping through for connected devices X. L operating voltage DC V X. N operating voltage 0 V X. L auxiliary power* DC V X. N auxiliary power* 0 V X.5 Function earth X X X X L+ L+ L+ L+ RJ5 IN OUT IN OUT Pin Description X. Receive Data +RD X. Receive Data RD_N X. Transmit Data +TD X. Ground GND (RJ5) X.5 Ground GND (RJ5) X.6 Transmit Data TD_N X.7 Ground GND (RJ5) X.8 Ground GND (RJ5) X: For looping through for connected devices (integrated RT switch) X. Receive Data +RD X. Receive Data RD_N X. Transmit Data +TD X. Ground GND (RJ5) X.5 Ground GND (RJ5) X.6 Transmit Data TD_N X.7 Ground GND (RJ5) X.8 Ground GND (RJ5) 79

80 Safety System MGB...PN... Technical data Parameter s ar max. door position Housing material Dimensions Weight of MGBL.B (bus module, locking module, and button module with mounting plate) Weight of handle module with mounting plate Weight of escape release module with mounting plate Value 65 mm Reinforced plastic diecast zinc, nickelplated, stainless steel, powdercoated sheet steel See dimension drawing.05 kg Ambient temperature C Degree of protection IP 5 Safety class Degree of contamination Installation position Locking force F zh.5 kg 0.9 kg III Any 000 N Connection options, power supply x pushpull power ) Connection type, bus x RJ 5, pushpull, according to IEC variant, screened ) Connection cable, bus Profinet I/O cable, at least cat. 5e Operating voltage U B DC V +0%/5% (PELV see electrical connection) Current consumption, max. Max. feedin current in the connection block (pushpull plug connector) Fuse protection for power supply, external 500 ma 000 ma Min. A slowblow Safety Profisafe according to IEC 678 Rated insulation voltage U i Rated impulse withstand voltage U imp Resilience to vibration and shock In accordance with EN EMC protection requirements As per EN 6000 and DIN EN 66 Switching frequency max. Risk times max. (switchoff times) ) Emergency stop Enabling switch Operating mode selector switch Guard position Bolt position Guard locking Reliability values according to EN ISO V 0.5 kv Hz 0 ms 0 ms 0 ms 550 ms 550 ms 550 ms Category (EN 89:008) Performance Level PL e (EN 89:008) MTTF d ) 9 years DC 99% Mission time PFH d ) B 0d ) Emergency stop Enabling switch ) The document PROFINET Cabling and Interconnection Technology from the PNO aids in the correct selection of. ) The risk time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol. ) Fixed failure rate without consideration of faults in wearing parts. ) Information regarding wearing parts without consideration of fixed failure rates in electronic components. 0 years.5 x 0 8 / h x 0 5 According to switch information from manufacturer 80

81 Safety System MGB...PN... Dimension drawings closed 05 Link Data Link Data SF BF ON U B open X DCV X DCV X PN X PN MGBPN , 0 6, Figure shows mounting with mounting plates (Figure shows version for doors hinged on the right, preassembled on mounting plates) 8

82 Item Index Index by item designation Item Order no. Page Item Order no. Page CMF9PU0,5MA MGBLARAB5AM CMF9PU0,0MA MGBLARAB8AM CMF9PU06,0MA MGBLARAB9ASL CMF9PU0,0MA MGBLARAB9ASR CMF9PU5,0MA MGBLARAB9AM CMF9PU0,0MA MGBLARACAM CMF9PU5,0MA MGBLARAC5AM Extended actuation axis MGBLARAAAASL MGBA HOUSING SLEEVE MGBLARAAAASR MGBA MOUNTING PLATE E MGBLARAAAASL MGBA MOUNTING PLATE E MGBLARAAAASL MGBA MOUNTING PLATE E MGBLARAAAASR MGBA MOUNTING PLATE H MGBLARAAAASR MGBA MOUNTING PLATE H MGBLARAAB5AM6 6 5 MGBA MOUNTING PLATE H MGBLARAAC8AM MGBA MOUNTING PLATE L MGBLARAAC9AM MGBA MOUNTING PLATE LC MGBLARAADAM MGBA MOUNTING PLATE LC MGBLARAADAM MGBA MOUNTING PLATE LC MGBLARAADASL MGBALPSET MGBLARAADASR MGBC000000A MGBLARAAD7AM6 6 9 MGBEA MGBLARAAD8AM5 5 9 MGBEA MGBLARAAD9AM5 5 9 MGBEA MGBLARAAEAM6 6 9 MGBHAAAR MGBLARAAEAM8 8 9 MGBHAAAL MGBLARAAEAM 5 MGBHAAAL MGBLBPNAL MGBHAAAR MGBLBPNAL MGBHAAAR MGBLBPNAR MGBHAAAR MGBLBPNAR MGBL0APAAA6ASL MGBLHAPAL MGBL0APAAA6ASR MGBLHAPAR MGBL0ARAAAM05 05 MGBLHAPAR MGBL0ARAAAM MGBLHARL MGBL0ARAA7AM MGBLHARR MGBL0ARAB5AM MGBLHARR MGBL0ARAAAASL MGBLHARR MGBL0ARAAAASR MGBLHARR MGBL0ARAAAASL MGBLHARR MGBL0ARAAAASR MGBLHARR MGBL0HAPAL MGBLHARAL MGBL0HAPAR MGBLHARAL MGBL0HARR MGBLHARAL MGBL0HARR MGBLHARAL7 7 5 MGBL0HARR MGBLHARAL5 5 9 MGBL0HARAL MGBLHARAL9 9 9 MGBL0HARAL MGBLHARAR MGBL0HARAR MGBLHARAR MGBL0HARAR MGBLHARAR MGBL0HEARR MGBLHARAR5 5 9 MGBL0HEARR MGBLHARAR7 7 9 MGBL0HEARR MGBLHARAR5 5 5 MGBL0HEARAL MGBLHBPNAL MGBL0HEARAR MGBLHBPNAR MGBLAPAAA6ASL MGBLHEARL MGBLAPAAA6ASR MGBLHEARR MGBLAPAAB6ASR MGBLHEARR MGBLARAAAM MGBLHEARR MGBLARAAAM MGBLHEARR MGBLARAA9AM MGBLHEARR MGBLARABAM MGBLHEARR MGBLARABASL MGBLHEARR MGBLARABASR MGBLHEARR

83 Item Index Item Order no. Page Item Order no. Page MGBLHEARR MPAB MGBLHEARAL MPACCH MGBLHEARAR MPACGM MGBLHEARAR MPACGU MGBLHEARAR MPACLCWH MGBLHEARAR MPAERD00A MGBLHEARAR 9 MPAH MGBLAPAAA6ASL MPAKRR00A MGBLAPAAA6ASR05 05 MPALR0RD MGBLAPAAB6ASL MPALR0WH MGBLAPAAB6ASR MPALR0YE MGBLAPAAC7ASL MPAPRTBUA MGBLAPAAC7ASR MPAPRTGNA MGBLARAAAM00 00 MPAPRTRDA MGBLARAAASL MPAPRTWHA MGBLARAAASR MPAPRTYEA MGBLARAAAM MPASRR00A MGBLARAAASL Pin crimp contact RCMC MGBLARAAASR RC8EFC MGBLARAA8AM RC8EF,5MC MGBLARAA9AM RC8EF,5MFC MGBLARAB8AM RC8EF0MC MGBLARACAM RC8EF0MFC MGBLARAAAASL RC8EF5MC MGBLARAAAASR RC8EF5MFC MGBLARAAB5AM0 0 6 RC8EF0MC MGBLARAAD5AM 7 RC8EF0MFC MGBLARAAD6AM6 6 7 RC8EF5MC MGBLARAAEAM RC8EF5MFC MGBLARAAEAM 50 RC8EF0MC MGBLARAAEAM8 8 6 RC8EFMC MGBLBPNAL RC8EFMFC MGBLBPNAL RC8EF6MC MGBLBPNAR RC8EF6MFC MGBLBPNAR RC8EF8MC MGBLHAPAL RC8EF8MFC MGBLHAPAL Replacement shaft length 50 mm MGBLHAPAR Replacement shaft length 50 mm MGBLHAPAR MGBLHARL MGBLHARL 6 MGBLHARR MGBLHARR MGBLHARR MGBLHARR9 9 6 MGBLHARAL MGBLHARAL 5 MGBLHARAL MGBLHARAR MGBLHARAR 5 MGBLHARAR MGBLHBPNAL MGBLHBPNAR MGBLHEAPAL MGBLHEAPAR MGBLHEARL0 0 5 MGBLHEARR MGBLHEARR MGBLHEARR MGBLHEARR MGBLHEARR MGBLHEARR MGBLHEARR

84 Item Index Index by order numbers Order no. Item Page Order no. Item Page 0770 RC8EF6MC MGBLHEARR RC8EF8MC MPALR0WH RC8EF5MC MPASRR00A RC8EFC MPAKRR00A RC8EF0MC MPAERD00A RC8EF5MC MPACGU RC8EF,5MC MPACGM RC8EFMC MPACLCWH RC8EF,5MFC MPACCH RC8EFMFC MPAH RC8EF6MFC MPAB RC8EF8MFC MGBA MOUNTING PLATE L RC8EF0MFC MGBA MOUNTING PLATE H RC8EF5MFC MGBA MOUNTING PLATE H RC8EF0MFC MGBA MOUNTING PLATE H RC8EF5MFC MGBA MOUNTING PLATE E RC8EF0MC MGBA MOUNTING PLATE E Pin crimp contact RCMC MGBA MOUNTING PLATE E RC8EF0MC MGBA HOUSING SLEEVE MGBHAAAR MGBLARABASR MGBEA MGBLARABASL MGBLARAAAM MGBLHARR MGBLARAAAM MGBLHARL MGBLARAAAM MGBLHARR MGBL0ARAAAM MGBLARAB5AM MPAPRTBUA MGBLAPAAB6ASR MPAPRTYEA MGBLAPAAB6ASR MPAPRTWHA MGBLHAPAR MPALR0RD MGBLHAPAR MPALR0YE MGBLARAAASR MGBL0HARR MGBLARAAASL MGBL0HARR MGBLHARR MGBL0HEARR MGBLHARL MGBL0HEARR MGBL0HARR MGBLHARR MGBL0ARAB5AM MGBLHARR MGBALPSET MGBLHEARR MGBLHEARR MGBLHEARR MGBLARAB8AM MGBLHARR MGBLHEARR MGBLHARR MGBLHEARR MGBLHEARR MGBLARAB9ASR MGBLHEARR MGBLHEARL MGBLARAAAM MGBLARAB9ASL MGBHAAAR MGBLARACAM MGBHAAAR MGBLHARR MGBEA MGBLARACAM MGBEA MGBLHEARR MGBL0ARAAAM MGBLHEARR MGBHAAAL MGBLARAB9AM MGBHAAAL MGBLHBPNAL Replacement shaft length 50 mm MGBLHBPNAR Replacement shaft length 50 mm MGBLBPNAR Extended actuation axis MGBLBPNAR MGBL0ARAA7AM MGBLBPNAL MGBL0HEARR MGBLBPNAL MGBLHEARR MGBA MOUNTING PLATE LC MGBLARAA8AM MGBA MOUNTING PLATE LC MGBC000000A MGBA MOUNTING PLATE LC MGBLARAA9AM MGBLHAPAL MGBLHEARR MGBLAPAAB6ASL MGBLARABAM MGBLHEARR MGBLARAA9AM MGBLHEARL MGBLHEARR MGBLARAAASR

85 Item Index Order no. Item Page Order no. Item Page 068 MGBLARAAASL MGBLARAADASL MGBLARAB8AM MGBL0HARAR MGBLHEARR MGBL0ARAAAASR MGBLARAC5AM MGBL0HARAL MGBLHARR MGBL0ARAAAASL CMF9PU0,5MA MGBL0HARAR CMF9PU0,0MA MGBL0HARAL CMF9PU06,0MA MGBLHARAR CMF9PU0,0MA MGBLARAAAASR CMF9PU5,0MA MGBLHARAL CMF9PU0,0MA MGBLARAAAASL CMF9PU5,0MA MGBHAAAR MPAPRTRDA MGBLHARAR MPAPRTGNA MGBLHARAL MGBLHEAPAR05 6 MGBLARAAD5AM 7 05 MGBLHEAPAL MGBLARAAD6AM MGBLAPAAC7ASR05 6 MGBLHEARAR 9 05 MGBLAPAAC7ASL MGBLHARAR MGBLAPAAA6ASR05 5 MGBLHARAL MGBLAPAAA6ASL055 5 MGBLARAAD8AM MGBL0APAAA6ASR MGBLARAAD9AM MGBL0APAAA6ASL MGBLARAAD7AM MGBLHAPAR058 6 MGBLARAAEAM MGBLHAPAL059 7 MGBLHARAR MGBL0HAPAR MGBLARAAEAM MGBL0HAPAL MGBLHARAL MGBLAPAAA6ASR MGBLARAAEAM MGBLAPAAA6ASL0586 MGBLHARAR MGBLHAPAR0587 MGBLARAAEAM MGBLHAPAL0588 MGBLHARAL 5 06 MGBLHARAR06 0 MGBLARAAEAM 5 06 MGBLHARAL MGBLHARAR MGBLHARAR MGBLARAAB5AM MGBLHARAL MGBLHARAL MGBLHBPNAL MGBLARAAEAM MGBLHBPNAR MGBLHARR MGBLARAAAASR MGBLARAAB5AM MGBLARAAAASL MGBLHARL MGBL0ARAAAASR MGBL0ARAAAASL MGBLHEARAR MGBLHEARAL MGBL0HEARAR MGBL0HEARAL MGBLARAAC8AM MGBLHEARR MGBLARAAAASR MGBLARAAAASL MGBLHEARAR MGBLARAAC9AM MGBLBPNAR MGBLBPNAR MGBLBPNAL MGBLBPNAL MGBLARAADAM MGBLHEARAR MGBLARAADAM MGBLHEARAR MGBLARAAAASR MGBLARAAAASL MGBLHARAR MGBLHARAL MGBLARAADASR

86 Intern ernation ational al Repr epresent sentativ atives Australia Micromax Sensors & Automation Unit, 060 Beaconsfield Street Silverwater, NSW 8 Tel Fax info@micromaxsa.com.au Austria EUCHNER G.m.b.H. Süddruckgasse 5 Tribuswinkel Tel. +59 Fax +555 info@euchner.at Benelux EUCHNER (BENELUX) BV Visschersbuurt 50 AC Papendrecht Tel Fax info@euchner.nl Brazil EUCHNER Ltda Av. Prof. Luiz Ignácio Anhaia Mello, no. 87 S. Lucas São Paulo SP Brasil CEP Tel Fax euchner@euchner.com.br Canada IAC & Associates Inc. 80 Fasan Drive Unit A Oldcastle, Ontario N0R L0 Tel Fax sales@iacnassociates.com China EUCHNER (Shanghai) Trading Co., Ltd. No. 8 Workshop A, HiTech Zone 50 Meinengda Road Songjiang 06 Shanghai Tel Fax info@euchner.com.cn Czech Republic EUCHNER electric s.r.o. Spielberk Office Center Holandská Brno Tel Fax +055 info@euchner.cz Denmark Duelco A/S Mommarkvej Sønderborg Tel Fax info@duelco.dk Finland Sähkölehto Oy Holkkitie Helsinki Tel Fax office@sahkolehto.fi France EUCHNER France S.A.R.L. Parc d'affaires des Bellevues Allée Rosa Luxembourg Bâtiment le Colorado 9560 ERAGNY sur OISE Tel Fax info@euchner.fr Hong Kong Imperial Engineers & Equipment Co. Ltd. Unit B /F Cheung Lee Industrial Building 9 Cheung Lee Street Chai Wan Hong Kong Tel Fax info@imperialelec.com Hungary EUCHNER Ges.mbH Magyarországi Fióktelep 05 Törökbálint FSD Park. Tel Fax info@euchner.hu India EUCHNER Electric (India) Pvt. Ltd. West End River View 0, First Floor Survey No. 69/, Aundh Pune 007 Tel Fax info@euchner.in Teknic Euchner Pvt. Ltd. 6, Electronics City Hosur Road Bangalore Tel Fax marketing@tekniceuchner.co.in Israel Ilan At Gavish Automation Service Ltd. 6 Shenkar St. Qiryat Arie 95 P.O. Box 08 Petach Tikva 900 Tel Fax mail@ilangavish.com Italy TRITECNICA S.r.l. Viale Lazio 6 05 Milano Tel Fax info@tritecnica.it Japan Solton Co. Ltd. 7, ShinYokohama Kohokuku, Yokohama Japan 00 Tel Fax sales@solton.co.jp Korea EUCHNER Korea Co., Ltd. RM 80 Daerung Technotown rd #8 GasangDong KumchonGu, Seoul Tel Fax info@euchner.co.kr Mexico SEPIA S.A. de C.V. Maricopa # 0 0, Col. Napoles. Del. Benito Juarez 080 Mexico D.F. Tel Fax alazcano@sepia.mx Poland ELTRON Pl. Wolnosci 7B 5007 Wroclaw Tel Fax eltron@eltron.pl Republic of South Africa RUBICON ELECTRICAL DISTRIBUTORS Reith Street, Sidwell 606 Port Elizabeth Tel Fax sales@rubiconelectrical.com Romania First Electric SRL 5, Luterana Street App. 7, Sector 006 Bucharest Tel. +09 Fax +09 office@firstelectric.ro Singapore Sentronics Automation & Marketing Pte Ltd. Blk, Ang Mo Kio Industrial Park A #0506 Singapore Tel Fax sentronics@pacific.net.sg Slovakia EUCHNER electric s.r.o. Spielberk Office Center Holandská Brno Tel Fax +055 info@euchner.cz Slovenia SMM d.o.o. Jaskova Maribor Tel Fax franc.kit@smm.si Spain EUCHNER, S.L. Gurutzegi Local Polígono Belartza 008 San Sebastian Tel Fax comercial@euchner.es Sweden Censit AB Box Värnamo Tel Fax info@censit.se Switzerland EUCHNER AG Grofstrasse Mels Tel Fax info@euchner.ch Taiwan Daybreak Int'l (Taiwan) Corp. F, No., ChungCheng Road Shihlin 5, Taipei Tel Fax day@ms.hinet.net Thailand Aero Automation Co., Ltd. 600/ Moo Phaholyothin Rd. Kukot, Lamlukka Patumthanee 0 Tel Fax aeroautomation@yahoo.co.th Turkey Entek Otomasyon Urunleri San.ve Tic.Ltd.Sti. Perpa Tic.Mer. B Blok Kat: No:6 6 8 Okmeydani / Istanbul Tel / 0 Fax entekotomasyon@entek.com.tr United Kingdom EUCHNER (UK) Ltd. Unit Petre Drive, Sheffield South Yorkshire S 7PZ Tel Fax +5 info@euchner.co.uk USA EUCHNER USA Inc. 67 Lyons Street East Syracuse, NY 057 Tel Fax info@euchnerusa.com EUCHNER USA Inc. Detroit Office 0 Hampton Circle Rochester Hills, MI 807 Tel Fax info@euchnerusa.com 86

87 Head office EUCHNER GmbH + Co. KG Kohlhammerstraße LeinfeldenEchterdingen Germany Tel. +9(0) Fax +9(0)7756 info@euchner.de euchner hner.com More than safety. than safety. More safety. More than More than safety. than safety. More safety. More than More than safety. than safety. More safety. More than More than safety. than safety. More safety. More than More than safety. than safety. More safety. More than More than safety. than safety. More safety. More than More than safety. More than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. Mor than safety. More than safety. More than than safety. More safety. More Automation than safety. More than safety. More than safe More than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safe More than safety. than safety. More safety. More than More than safety. than safety. More safety. More than More than safety. than safety. More safety. More than More than safety. than safety. More safety. More than More than safety. than safety. More safety. More than More Safety than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. Mor More than safety. than safety. More ManMachine than safety. More than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. More than safety. Mor than safety. More than safety. More than safety. More than safety. More than safety. More than safety. More than safe More than safety. More than safety. More than safety. Mor 0/ 87

88 How to find "your" MGB: Step Find the right system family AP AR MGBAP for separate operation MGBAR for separate operation or series connection with other AR devices PN MGBPN for operation in PROFINET environment Step Interlocking or guard locking? MGBL0...: Interlocking (only monitoring of the door position) MGBL...: Guard locking by spring force (Closedcircuit current principle) MGBL...: Guard locking by solenoid force (Opencircuit current principle) Step Select number of controls/indicators required Configuration scheme/ counting direction Step Select type of controls and indicators Emergency stop according to ISO 850 / Illuminated emergency stop / emergency stop with auxiliary contact Machine stop / Pushbutton, illuminated / not illuminated (Different colors available) Lamp (Different colors available) 0 Selector switch form V, stage (Different versions available. For details see ordering table and description of the details) 0 / 0 Keyoperated selector switch form L or V, stage (Different versions available. For details see ordering table and description of the details) Step 5 Select complete MGB set with the required configuration Evaluation Handle Escape release (if required) Complete MGB = Have you not been able to find the configuration you require?? You will find further information at Alternatively our product consultants are available to assist you from the factory or on site. For explanation of symbols see also page 8.

89 How to find your M GB

90 EUCHNER GmbH + Co. KG Kohlhammerstraße LeinfeldenEchterdingen Germany Tel. +9(0) Fax +9(0)7756 info@euchner.de /0 Subject to technical modifi cations without notice, no liability will be assumed for any detail. EUCHNER GmbH + Co. KG TA More than safety.

MGB. Multifunctional Gate Box MGB. How to find your

MGB. Multifunctional Gate Box MGB. How to find your EN DE EUCHNER GmbH + Co. KG Kohlhammerstraße 6 7077 LeinfeldenEchterdingen Germany Tel. +9 7 7597 0 Fax +9 7 756 info@euchner.de www.euchner.com How to find your MGB 0609050/ Subject to technical modifications

More information

More than safety. System Manual Safety System MGB-AR in combination with a locking module MGB-L1-AR-.../MGB-L2-AR-...

More than safety. System Manual Safety System MGB-AR in combination with a locking module MGB-L1-AR-.../MGB-L2-AR-... More than safety. System Manual Safety System MGB-AR in combination with a locking module MGB-L1-AR-.../MGB-L2-AR-... Contents Correct Use 3 Exclusion of Liability and Warranty 4 General Safety Instructions

More information

Safety Switches CES-AR/CET-AR

Safety Switches CES-AR/CET-AR CES-A-L XXXXXX Safety Switches Component overview for non-contact safety switches Connection cable Safety switch Actuator Bolt CES-A-BBA Page 1 CES-A-BCA Page 1 Page 10 CES-AR-C01-... Page 10 CES-A-BPA

More information

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC Non-contact safety system CES-FD- Evaluation of signals in the field Connection of CES read heads Connection to the ET200s and ET200pro Familiar EUCHNER AP interface Functional description Field evaluation

More information

Transponder-coded. with guard locking

Transponder-coded. with guard locking Transponder-coded safety switch CTP with guard locking The safety switch CTP The new safety switch CTP combines the proven principle of operation of electromechanical safety switches with guard locking

More information

Safety Switches CES-AR/CET-AR

Safety Switches CES-AR/CET-AR Non-contact safety switches CET-AR-... with guard locking and guard lock monitoring Safety switch with guard locking and integrated evaluation electronics Locking force up to 00 N Up to 0 switches in series

More information

Presentation. EUCHNER Multifunctional Gate Box MGB

Presentation. EUCHNER Multifunctional Gate Box MGB Presentation EUCHNER Multifunctional Gate Box MGB Page 1 EUCHNER Multifunctional Gate Box MGB Guard locking / Interlocking Device Interlocking device MGB-L 0. Locking device MGB-L 1 Mechanical locking/

More information

More than safety. Joystick Switches

More than safety. Joystick Switches More than safety. Joystick Switches ManMachine More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in motion

More information

Non-Contact Safety System CMS. Magnetic Coding. More than safety.

Non-Contact Safety System CMS. Magnetic Coding. More than safety. Non-Contact Safety System CMS Magnetic Coding More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the

More information

INDUSTRY. Ongoing dialog. Communication at Industry 4.0 level

INDUSTRY. Ongoing dialog. Communication at Industry 4.0 level INDUSTRY Ongoing dialog Communication at Industry 4.0 level Safety switch CES-C07 There is more than meets the eye to EUCHNER s smallest safety switch. Its actual innovation is on the inside. The CES-C07

More information

Non-Contact Safety System CES-AZ

Non-Contact Safety System CES-AZ Read head CET-AX-... Read head with guard locking and guard lock monitoring Up to category High locking forces up to 00 N Integrated transponder coding Metal housing Design and functionality With the read

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

Online data sheet. T40-E0101K T4000 Direct NON-CONTACT SAFETY SWITCHES

Online data sheet. T40-E0101K T4000 Direct NON-CONTACT SAFETY SWITCHES Online data sheet T40-E0101K T4000 Direct A B C D E F H I J K L M N O P Q R S T actuator not supplied with delivery Detailed technical data Features System part Sensor principle Ordering information Type

More information

Product Overview Safety Engineering electronic

Product Overview Safety Engineering electronic Product Overview Safety electronic EN Without guard locking Safety System Multifunctional Gate Box MGB With/Without guard With guard locking With guard locking locking Control module MGB-L0 MGB-L1/L2 MGB

More information

Non-Contact Safety Switch CMS. Magnetic Coding. More than safety.

Non-Contact Safety Switch CMS. Magnetic Coding. More than safety. Non-Contact Safety Switch CMS Magnetic Coding More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the

More information

Transponder-coded safety switches Interlocking devices and guard locking devices

Transponder-coded safety switches Interlocking devices and guard locking devices Transponder-coded safety switches Interlocking devices and guard locking devices EN Internationally successful the EUCHNER company Headquarters in Leinfelden-Echterdingen EUCHNER GmbH + Co. KG is a world-leading

More information

Non-Contact Safety System CES-AZ

Non-Contact Safety System CES-AZ Evaluation unit CE-AZ-AE-01B/ CE-AZ-UE-01B 1) 2) 1 read head can be connected 2 safety outputs (relay contacts with 2 internally connected NO contacts per output) tart button and feedback loop can be connected

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

Magnetically Coded Safety Switches CMS

Magnetically Coded Safety Switches CMS Magnetically Coded Safety Switches CMS EN Internationally successful the EUCHNER company Headquarters in Leinfelden-Echterdingen EUCHNER GmbH + Co. KG is a world-leading company in the area of industrial

More information

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Datasheet - MZM 100 B ST2-1P2PW2RE-A 19.03.2014-11:42:51h Datasheet - MZM 100 B ST2-1P2PW2RE-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

Online data sheet. i10-e0454 Lock i10 Lock SAFETY LOCKING DEVICES

Online data sheet. i10-e0454 Lock i10 Lock SAFETY LOCKING DEVICES Online data sheet i10-e0454 Lock i10 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i10-e0454 Lock 6045056 The actuator has to be ordered separately. See "Accessories"

More information

More than safety. Operating Instructions Non-Contact Safety Switch CES-AP-CR2-AH (Unicode) CES-AP-CL2-AH (Unicode)

More than safety. Operating Instructions Non-Contact Safety Switch CES-AP-CR2-AH (Unicode) CES-AP-CL2-AH (Unicode) More than safety. Operating Instructions Non-Contact Safety Switch CES-AP-CR2-AH (Unicode) CES-AP-CL2-AH (Unicode) Contents About this document 3 Correct use 3 Possible combinations for CES components

More information

System family AR. Transponder-coded safety switch CET.-AR- With guard locking

System family AR. Transponder-coded safety switch CET.-AR- With guard locking System family R Transponder-coded safety switch CET.-R- With guard locking 1...20 Cat. 4 PLe Safety switch with guard locking Locking force up to 600 N etal housing Diagnostics via 4 LEDs Notice The device

More information

Online data sheet. i15-mm0123 Lock i15 Lock SAFETY LOCKING DEVICES

Online data sheet. i15-mm0123 Lock i15 Lock SAFETY LOCKING DEVICES Online data sheet i15-mm03 Lock i15 Lock i15-mm03 Lock i15 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i15-mm03 Lock 6034024 The actuator has to be ordered separately.

More information

Connection of MGB-L2..-AR to safety relay PNOZ s5

Connection of MGB-L2..-AR to safety relay PNOZ s5 Connection of MGB-L2..-AR to safety relay PNOZ s5 Content Guard locking power on applied spring released according to EN ISO 14119 (open-circuit current principle)... 2 Components/modules used... 2 EUCHNER...

More information

Online data sheet. i110-e0453 i110 Lock SAFETY LOCKING DEVICES

Online data sheet. i110-e0453 i110 Lock SAFETY LOCKING DEVICES Online data sheet i0-e0453 i0 Lock i0-e0453 i0 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i0-e0453 6051601 The actuator has to be ordered separately. See "Accessories"

More information

Connection of serial wired MGB-L1..-AR to Safety Relay MSR127TP

Connection of serial wired MGB-L1..-AR to Safety Relay MSR127TP Connection of serial wired MGB-L1..-AR to Safety Relay MSR127TP Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules

More information

Connection of CET3-AR to safety relay PNOZ X3.10P

Connection of CET3-AR to safety relay PNOZ X3.10P Connection of CET3-AR to safety relay PNOZ X3.10P Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules used... 2 EUCHNER...

More information

Operating Instructions

Operating Instructions Key Adapter CKS-K-AS2A-U-C20-PC (Unicode) EN Contents 1. About this document... 3 1.1. Scope...3 1.2. Target group...3 1.3. Key to symbols...3 1.4. Supplementary documents...3 2. Correct use... 4 3. Description

More information

Datasheet - MZM 100 B ST-1P2PW2REM-A

Datasheet - MZM 100 B ST-1P2PW2REM-A 19.07.2016-15:57:28h Datasheet - MZM 100 B ST-1P2PW2REM-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

Online data sheet. i10-m0233 Lock i10 Lock SAFETY LOCKING DEVICES

Online data sheet. i10-m0233 Lock i10 Lock SAFETY LOCKING DEVICES Online data sheet i10-m0233 Lock i10 Lock i10-m0233 Lock i10 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i10-m0233 Lock 60580 The actuator has to be ordered

More information

Datasheet - AZM300Z-ST-1P2P-A

Datasheet - AZM300Z-ST-1P2P-A 08.04.2015-16:04:56h Datasheet - AZM300Z-ST-1P2P-A Solenoid interlock / AZM300 Suitable for mounting to profile systems Thermoplastic enclosure 3 different directions of actuation Compact design 3 LEDs

More information

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches HSA-DMC Magnetic Safety Switches Key features: Compact size and easy positioning. Combination with proprietary relay modules achieves safety category 4 (EN954-1). Compact size ( 16 51mm) Positioning for

More information

Operating Instructions

Operating Instructions Transponder-Coded Safety Switch With Guard Locking CET.-AR- (Unicode/Multicode) EN Contents 1. About this document... 4 1.1. Scope...4 1.2. Target group...4 1.3. Key to symbols...4 1.4. Supplementary documents...4

More information

Non-Contact Safety System CES-AZ

Non-Contact Safety System CES-AZ , 0 M 8 8,, 7,,,, 0 0 7 0 7 Mounting plate CEM For read head CEM-A-LE0... and actuator CEM-A-BE0... Material stainless steel Mounting plate EMP-L-CEM0 For read head CEM-A-LE0... 9 8 0 8 M - x, 7 Mounting

More information

Operating Instructions

Operating Instructions AR Evaluation Unit CES-AR-AES-12 EN Contents 1. About this document... 4 1.1. Scope...4 1.2. Target group...4 1.3. Key to symbols...4 1.4. Supplementary documents...4 2. Correct use... 5 3. Exclusion of

More information

Connection of MGB-L1..-AR to Safety Relay ESM-BA..1

Connection of MGB-L1..-AR to Safety Relay ESM-BA..1 Connection of MGB-L1..-AR to Safety Relay ESM-BA..1 Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules used... 2

More information

Connection of serial wired CES-AR to safety relay ESM-BA..1 Content

Connection of serial wired CES-AR to safety relay ESM-BA..1 Content Connection of serial wired CES-AR to safety relay ESM-BA..1 Content Interlocking device according to EN ISO 14119... 2 Components/modules used... 2 EUCHNER... 2 Functional description... 3 General... 3

More information

System family AP. Safety switch CET.-AP- With guard locking

System family AP. Safety switch CET.-AP- With guard locking System family P Safety switch ET.-P- With guard locking at. 4 PLe Safety switch with guard locking Locking force up to 600 N Metal housing Diagnostics via 4 LEDs Notice The device is only allowed to be

More information

Available coding options

Available coding options System family P Safety switch TP- -P- With guard locking at. 4 PLe 1) Safety switch with guard locking Locking force up to 2600 N Diagnostics via 3 LEDs PL e/category 4 Notice The device is only allowed

More information

More than safety. Product Overview. Safety Engineering

More than safety. Product Overview. Safety Engineering More than safety. Product Overview Safety Engineering Safety Engineering at a Glance Non-Contact Safety Systems Transponder Coding CES-A-C5 Safety system CES-A-A Safety system CES-AZ-A Approvals Safety

More information

Datasheet AZM 161 Z ST1 AS RA

Datasheet AZM 161 Z ST1 AS RA 25.10.2016 10:35:58h Datasheet AZM 161 Z ST1 AS RA AS interface safety at work / Safety switchgear / Solenoid interlock / AZM 161 AS Preferred typ Solenoid interlock Thermoplastic enclosure High holding

More information

Datasheet - RSS 36-D-R-ST

Datasheet - RSS 36-D-R-ST 14.03.2018-19:30:37h Datasheet - RSS 36-D-R-ST Safety sensors / RSS 36 Thermoplastic enclosure RFID-technology for needs-based protection against tampering Misaligned actuation possible 27 mm x 108.2 mm

More information

More than safety. Operating Instructions Non-Contact Safety Switch CES-AR-CR2-AH (Unicode) CES-AR-CL2-AH (Unicode)

More than safety. Operating Instructions Non-Contact Safety Switch CES-AR-CR2-AH (Unicode) CES-AR-CL2-AH (Unicode) More than safety. Operating Instructions Non-Contact Safety Switch CES-AR-CR2-AH (Unicode) CES-AR-CL2-AH (Unicode) Contents Correct use 3 Possible combinations for CES components 4 Exclusion of liability

More information

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches R Safety Interlock Switches CM Series CM For full product information, visit www.sti.com. Use the SpeedSPEC Code for quick access to the specific web page. Most Diverse and Flexible Line of Coded Magnetic

More information

Datasheet - AZM 200 BZ ST-T-AS P

Datasheet - AZM 200 BZ ST-T-AS P 11.02.2013-20:17:11h Datasheet - AZM 200 BZ ST-T-AS P AS interface safety at work / Safety switchgear / Solenoid interlock / AZM 200 AS Preferred typ Solenoid interlock Thermoplastic enclosure High holding

More information

Connection of MGB-L2..-AR to safety relay PNOZ X3.10P

Connection of MGB-L2..-AR to safety relay PNOZ X3.10P Connection of MGB-L2..-AR to safety relay PNOZ X3.10P Content Guard locking spring applied power on released according to EN ISO 14119 (open-circuit current principle)... 2 Components/modules used... 2

More information

Operating Instructions

Operating Instructions Transponder-Coded Safety Switch With Guard Locking CET.-AP- (Unicode/Multicode) EN Contents 1. About this document... 4 1.1. Scope...4 1.2. Target group...4 1.3. Key to symbols...4 1.4. Supplementary documents...4

More information

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... 6 Disassembly and disposal 6.1 Disassembly....6 6.2 Disposal...6 7 EU Declaration of conformity Operating instructions.............pages 1 to 8 Original x.000 / 09.2017 / v.a. - 101178533- / I / 2017-08-31

More information

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016 Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6

More information

Operating Instructions

Operating Instructions Operating Instructions Safety Systems MGB-L0 -AR.- MGB-L0 -AP.- from V3.0.0 EN Contents 1. About this document... 4 1.1. Scope...4 1.1.1. Notes on older product versions...4 1.2. Target group...4 1.3.

More information

Online data sheet. i200-m0323 Lock i200 Lock SAFETY LOCKING DEVICES

Online data sheet. i200-m0323 Lock i200 Lock SAFETY LOCKING DEVICES Online data sheet i200-m0323 Lock i200 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i200-m0323 Lock 6025113 The actuator has to be ordered separately. See "Accessories"

More information

Transponder-coded safety systems with external evaluation

Transponder-coded safety systems with external evaluation Transponder-coded safety systems with external evaluation EN Internationally successful the EUCHNER company Headquarters in Leinfelden-Echterdingen EUCHNER GmbH + Co. KG is a world-leading company in the

More information

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... Safety sensor BNS 0 Disassembly and disposal. Disassembly..... Disposal... 7 EU Declaration of conformity Operating instructions.............pages to Original x.000 / 09.08 / v.a. - 08- / Q / 08-09- /

More information

More than safety. Operating Instructions Non-Contact Safety Switch CES-AR-C01-EH-SA (Fixcode)

More than safety. Operating Instructions Non-Contact Safety Switch CES-AR-C01-EH-SA (Fixcode) More than safety. Operating Instructions Non-Contact Safety Switch CES-AR-C01-EH-SA (Fixcode) Contents Correct use 3 Possible combinations for CES components Exclusion of liability and warranty General

More information

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GG711S Original operating instructions Fail-safe inductive sensor GG7S 8236522 / 2 / 26 Contents Preliminary note...3. Symbols used...3.2 Warning signs used...3 2 Safety instructions...4 2. Safety-related requirements

More information

Connection of CES-AR to safety relay ESM-BA..1 Content

Connection of CES-AR to safety relay ESM-BA..1 Content Connection of CES-AR to safety relay ESM-BA..1 Content Interlocking device according to EN ISO 14119... 2 Components/modules used... 2 EUCHNER... 2 Functional description... 3 General... 3 Connections...

More information

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GI712S Original operating instructions Fail-safe inductive sensor GI712S 80236527 / 00 12 / 2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related

More information

Datasheet - AZM 200SK-T-1P2PW

Datasheet - AZM 200SK-T-1P2PW 08.04.2015-16:16:26h Datasheet - AZM 200SK-T-1P2PW Solenoid interlock / AZM 200 thermoplastic enclosure Guard locking monitored Electronic contact-free, coded system Max. length of the sensor chain 200

More information

Safe switching and monitoring Non-Contact Safety Sensors

Safe switching and monitoring Non-Contact Safety Sensors Safe switching and monitoring Non-Contact Safety Sensors Electronic safety sensors are used to detect guard door closure. These sensors use noncontact operating principles (pulse echo or RFID) that limits

More information

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS Safety Controller Suitable for use with Coded-Magnet Sensor Part Numbers below BNS250... BNS33... BNS303...

More information

More than safety. Operating Instructions Non-Contact Safety Switch with Guard Locking CET.-AP-... (from V 1.5.0)

More than safety. Operating Instructions Non-Contact Safety Switch with Guard Locking CET.-AP-... (from V 1.5.0) More than safety. Operating Instructions Non-Contact Safety Switch with Guard Locking CET.-AP-... (from V 1.5.0) Contents Scope 3 Correct use 3 Possible combinations for CES components 4 Exclusion of liability

More information

Tongue Switches Trojan 5 & 6

Tongue Switches Trojan 5 & 6 Interlock Switches Description The Trojan family is a universal tongue (or key) actuated safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. The dual key

More information

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Safety relay with relay outputs G1501S / / 2016 Original operating instructions Safety relay with relay outputs G50S UK 8023637 / 00 02 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions

More information

More than safety. Operating Instructions Non-Contact Safety Switch with Guard Locking CET.-AR-...-AH-... (Unicode)

More than safety. Operating Instructions Non-Contact Safety Switch with Guard Locking CET.-AR-...-AH-... (Unicode) More than safety. Operating Instructions Non-Contact Safety Switch with Guard Locking CET.-AR-...-AH-... (Unicode) Contents Scope Correct use Possible combinations for CES components Exclusion of liability

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

Online data sheet. i200-m0413 Lock i200 Lock SAFETY LOCKING DEVICES

Online data sheet. i200-m0413 Lock i200 Lock SAFETY LOCKING DEVICES Online data sheet i200-m03 Lock i200 Lock i200-m03 Lock i200 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i200-m03 Lock 6025115 The actuator has to be ordered

More information

Connection of CET4-AR to Siemens ET 200S

Connection of CET4-AR to Siemens ET 200S Connection of CET4-AR to Siemens ET 200S Content Guard locking power on applied spring released according to EN ISO 14119 (open-circuit current principle)... 2 Components/modules used... 2 EUCHNER... 2

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts. Auxiliary Contacts

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts. Auxiliary Contacts Safety TLS- General 1-2-Opto-electronics 3-Interlock Logic Description The TLS- is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min TLS- General 1-2-Opto-electronics 3-Interlock Logic Description The TLS- is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated and

More information

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content Operating instructions.............pages 1 to 8 Original 6 Diagnostic 6.1 LED indications...5 6.2 Error....5 6.3 Locking of the solenoid interlock blocked...5 6.4 Diagnostic information...5 6.5 Diagnostic

More information

Operating instructions Solenoid interlock MZM 100 MZM 100 B. 1. About this document. Content

Operating instructions Solenoid interlock MZM 100 MZM 100 B. 1. About this document. Content 8 Disassembly and disposal 8.1 Disassembly 9 8.2 Disposal 9 Operating instructions pages 1 to 12 Original 9 Appendix 9.1 Wiring examples 10 9.2 Wiring configuration and connector accessories 11 10 EU Declaration

More information

Connection of serial wired CTP-L1..-AR to Safety Relay ESM-BA..1

Connection of serial wired CTP-L1..-AR to Safety Relay ESM-BA..1 Connection of serial wired CTP-L1..-AR to Safety Relay ESM-BA..1 Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules

More information

Tongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications.

Tongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications. 1-2 -Interlock Safety 4 Description The Trojan family is a universal tongue-operated (or key-operated) safety-interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards.

More information

More than safety. Operating instructions Non-contact safety system CES-A-ABA-01/CES-A-ABA-01B (Unicode)

More than safety. Operating instructions Non-contact safety system CES-A-ABA-01/CES-A-ABA-01B (Unicode) More than safety. Operating instructions Non-contact safety system CES-A-ABA-01/CES-A-ABA-01B (Unicode) Contents Correct Use 3 Possible combinations for CES components 4 Exclusion of Liability and Warranty

More information

Connection of CET3-AR to Pilz PDP67

Connection of CET3-AR to Pilz PDP67 Connection of CET3-AR to Pilz PDP67 Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules used... 2 EUCHNER... 2 Other...

More information

Specifications. Functional Safety Data Note: For up-to-date information, visit Certifications.

Specifications. Functional Safety Data Note: For up-to-date information, visit  Certifications. Safety Non-Contact General 1-2-Opto-electronics 3-Interlock Logic Description When it comes to machine safety, Rockwell Automation knows that protection of personnel and equipment is your main concern.

More information

Operating instructions Solenoid interlock MZM About this document. Content

Operating instructions Solenoid interlock MZM About this document. Content MZM 100 1. About this document Operating instructions pages 1 to 10 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you need

More information

Online data sheet. TR4-SDM03P TR4 Direct NON-CONTACT SAFETY SWITCHES

Online data sheet. TR4-SDM03P TR4 Direct NON-CONTACT SAFETY SWITCHES Online data sheet TR4-SDM03P TR4 Direct A B C D E F H I J K L M N O P Q R S T Detailed technical data Features System part Sensor principle Ordering information Other models and accessories Number of safe

More information

Operating instructions Safety switch with interlocking function MZM 100 B. 1. About this document. Content

Operating instructions Safety switch with interlocking function MZM 100 B. 1. About this document. Content 1. About this document Operating instructions............pages 1 to 10 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you

More information

Operating Instructions

Operating Instructions Transponder-Coded Safety Switch, Guard Locking for Process Protection CEM-AR Unicode/Multicode CEM-AY Unicode EN Contents 1. About this document... 4 1.1. Scope...4 1.2. Target group...4 1.3. Key to symbols...4

More information

Connection of CET3-AR to Pilz PDP67

Connection of CET3-AR to Pilz PDP67 Connection of CET3-AR to Pilz PDP67 Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules used... 2 EUCHNER... 2 Other...

More information

Versatile and safe. Transponder-coded safety systems CES

Versatile and safe. Transponder-coded safety systems CES Versatile and safe. Transponder-coded safety systems CES Transponder-coded safety systems CES The coded electronic safety systems CES are modern interlocking devices of type 4 for the protection of people,

More information

Online data sheet STR1-SASM03P5 STR1 NON-CONTACT SAFETY SWITCHES

Online data sheet STR1-SASM03P5 STR1 NON-CONTACT SAFETY SWITCHES Online data sheet STR1-SASM03P5 STR1 A B C D E F H I J K M N O P Q R S T Detailed technical data Features System part Sensor principle Ordering information Other models and accessories Number of safe outputs

More information

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

Operating instructions Solenoid interlock AZM 200 T. 1. About this document. Content

Operating instructions Solenoid interlock AZM 200 T. 1. About this document. Content 7 Set-up and maintenance 7.1 Functional testing...7 7.2 Maintenance...7 Operating instructions............pages 1 to 10 Translation of the original operating instructions 8 Disassembly and disposal 8.1

More information

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system The SMART With an innovative diagnostic system Actual size shown Very compact: small in size, flexible in use Very Smart: suitable for Industry 4.0 with its intelligent diagnostic system Cost Saving: four-wire

More information

More than safety. Operating instructions Non-contact safety system CES-A-AEA-02B/CES-A-AEA-04B (Unicode)

More than safety. Operating instructions Non-contact safety system CES-A-AEA-02B/CES-A-AEA-04B (Unicode) More than safety. Operating instructions Non-contact safety system CES-A-AEA-02B/CES-A-AEA-04B (Unicode) Contents Correct Use 3 Possible combinations for CES components 4 Exclusion of Liability and Warranty

More information

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un): Safety module CS AR-91, according to EN 81 Safety modules for the lift automatic floor levelling operation according to EN 81 Main functions For safety applications up to SIL 3 / PL e Choice between automatic

More information

Online data sheet. S30A-7021EK S3000 Anti Collision SAFETY LASER SCANNERS

Online data sheet. S30A-7021EK S3000 Anti Collision SAFETY LASER SCANNERS Online data sheet S30A-7021EK S3000 Anti Collision A B C D E F system plug not supplied with delivery Ordering information Type Part no. S30A-7021EK 1071544 Usage Can only be used in the EFI system network,

More information

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content 7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10

More information

Online data sheet RE13-SAC RE1 NON-CONTACT SAFETY SWITCHES

Online data sheet RE13-SAC RE1 NON-CONTACT SAFETY SWITCHES Online data sheet RE13-SAC RE1 A B C D E F H I J K L M N O P Q R S T Detailed technical data Features System part Sensor principle Ordering information Other models and accessories Number of N/O contacts

More information

Operating Instructions

Operating Instructions Non-Contact Safety Switch CES-AP-C01- (Unicode/Multicode) EN Contents 1. About this document... 4 1.1. Scope...4 1.2. Target group...4 1.3. Key to symbols...4 1.4. Supplementary documents...4 2. Correct

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap

More information

Operating instructions Safety switch with interlocking function AZM 200D. 1. About this document. Content

Operating instructions Safety switch with interlocking function AZM 200D. 1. About this document. Content 8 Appendix 8.1 Wiring example...6 8.2 Wiring configuration and connector accessories...7 9 EU Declaration of conformity Operating instructions.............pages 1 to 8 Original x.000 / 11.2017 / v.a. -

More information

SERIES AZ15/16. Tamper-Resistant Movable Machine Guard Safety Interlock Switch. Features & Benefits. Description. Operation. Typical Applications

SERIES AZ15/16. Tamper-Resistant Movable Machine Guard Safety Interlock Switch. Features & Benefits. Description. Operation. Typical Applications SERIES AZ15/ Tamper-Resistant Movable Machine Guard Safety Interlock Switch The Series AZ15/ is designed for use with movable machine guards/access gates which must be closed for operator safety. Their

More information

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where

More information

SR B series coded magnetic safety sensors

SR B series coded magnetic safety sensors SR B series coded magnetic safety sensors Selection diagram CONTACTS 0 NC NC+NO NC+NO Contact states are displayed for closed guard SENSOR ACTUATOR OUTPUT TYPE SM B0F Actuation distance mm SM B0F Actuation

More information

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R 13.06.2016 05:27:33h Datasheet AZM 161SK 12/12RI 024 B6R Solenoid interlock / AZM 161I / AZM 161I B6R right hand model Compact design Interlock with protection against incorrect locking. For very smal

More information

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1 FSO Webnair FSO Safety Functions Module February 11, 2015 Slide 1 Competence Requirements for ABB Commissioner / Service Engineer of ACS880 Drives with FSO The integrated Safety Function Module (FSO; option

More information