System family AR. Transponder-coded safety switch CET.-AR- With guard locking

Size: px
Start display at page:

Download "System family AR. Transponder-coded safety switch CET.-AR- With guard locking"

Transcription

1 System family R Transponder-coded safety switch CET.-R- With guard locking Cat. 4 PLe Safety switch with guard locking Locking force up to 600 N etal housing Diagnostics via 4 LEDs Notice The device is only allowed to be operated in conjunction with the actuator CET--. Details pproach direction Head can be rotated in 90 -steps vailable coding options nicode evaluation ulticode evaluation Category according to EN ISO The category is dependent on the installation position: Installation position Category/PL Cat. 3 PLe Cat. 4 PLe Guard locking types CET1 Closed-circuit current principle Guard locking by spring force. Release by applying voltage to the guard locking solenoid. CET2 Open-circuit current principle Guard locking by solenoid force. ctivation of the guard locking by applying voltage to the guard locking solenoid. CET3 Function as for CET1-R, but here the door position is also monitored. the door monitoring output OT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OT D remains set also with guard locking active. CET4 Function as for CET2-R, but here the door position is also monitored. the door monitoring output OT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OT D remains set also with guard locking active. uxiliary release Included with all versions as standard. Escape release (optional) Some devices have an escape release (see ordering table). Wire front release (optional) The wire front release permits remote release of the guard locking via a pull wire. Flexible routing of the pull wire permits release of the guard locking in inaccessible installation situations. Teach-in input (optional) Some devices with unicode evaluation have a teach-in input. These devices can only be taughtin by switching the teach-in input. In this way the protection against tampering is additionally increased. Lockout bar (optional) The lockout bar can be used to prevent maintenance personnel from being unintentionally locked in the danger area, for example. In locked position, the lockout bar prevents activation of guard locking. The lockout bar can be secured in locked position with up to three locks. Double ramp Versions with double ramp can be approached from two sides. Devices with double ramp are also suitable for applications in which the switch must be "passed over". E.g. on doors that can be opened inwards and outwards. The double ramp can be retrofitted (see accessories page 113). Feedback loop (optional) Versions with feedback loop permit monitoring of connected devices (e.g. contactors). dditionally, a start button can be integrated. LED indicator STTE Status DI Diagnostics LED 1 red See wiring diagram LED 2 green See wiring diagram dditional connections OT onitoring output (semiconductor) OT D Door monitoring output (only CET3/4) RST Reset input Further information Dimension drawings see p. 78 ccessories and spare parts see p. 77 For detailed information, enter the order number You will find information on the series connection of R device on page. 72 Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16

2 Ordering table CET.-R- -SG- with 2 plug connectors 12, without door monitoring 8 Order No./item Coding = unicode = multicode Ramp Teach-in input Feedback loop Escape release Wire front release (L1) 1) Lockout bar For wiring diagram see page 80 CET1 Closed-circuit current principle CET1-R-CD-H-0X-SG CET1-R-CR-H-0-SG mm CET1-R-CR-H-0F-SG mm CET1-R-CR-H-0F-SG-C mm CET1-R-CR-H-0S-SG CET1-R-CR-H-0X-SG CET1-R-CR-H-0X-SG-C CET1-R-CR-H-0S-SG-C CET1-R-CR-CH-0F-SG CET1-R-CR-CH-0S-SG CET1-R-CR-CH-0X-SG m 7 mm For detailed information, enter the order number CET1-R-CR-CH-0X-SG-C m B CET1-R-CD-CH-0X-SG CET1-R-CR-CH-0F-SG-C CET2 Open-circuit current principle CET2-R-CR-H-0S-SG CET2-R-CR-H-0X-SG CET2-R-CR-CH-0F-SG-C CET2-R-CR-CH-0X-SG mm 10 mm 1) L1 = sleeve length; cable length = L1 + 1 m. Important: Handle must be ordered separately (see accessories page 112). Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16 73

3 System family R CET.-R- -SG- with 2 plug connectors 12, with door monitoring output 8 Order No./item Coding = unicode = multicode Ramp Teach-in input Feedback loop Escape release Wire front release (L1) 1) Lockout bar For wiring diagram see page 80 CET3 Closed-circuit current principle CET3-R-CR-CH-0X-SG-C m CET3-R-CR-CH-0F-SG-C CET3-R-CR-CH-0X-SG CET3-R-CR-CH-0F-SG CET3-R-CR-H-0X-SG CET3-R-CR-H-0X-SG-C CET3-R-CR-H-0X-SG-C CET3-R-CR-H-0F-SG CET3-R-CR-H-0F-SG-C CET3-R-CR-CH-0F-SG-C CET3-R-CR-CH-0S-SG CET3-R-CR-CH-0F-SG-C CET3-R-CD-CH-0F-SG mm 3 m 7 mm 3 m 7 mm 7 mm 7 mm 10 mm B C For detailed information, enter the order number CET4 Open-circuit current principle CET4-R-CR-H-0X-SG CET4-R-CR-H-0X-SG-C m CET4-R-CR-H-0X-SG-C CET4-R-CR-CH-0X-SG CET4-R-CR-CH-0X-SG-C CET4-R-CR-CH-0F-SG CET4-R-CR-CH-0S-SG mm C CET4-R-CD-CH-0X-SG CET4-R-CR-CH-0X-SG-C D 1) L1 = sleeve length; cable length = L1 + 1 m. Important: Handle must be ordered separately (see accessories page 112). 74 Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16

4 CET.-R- -SH- with plug connector RC18 23 (no L approval), without door monitoring output Order No./item Coding = unicode = multicode Ramp Teach-in input Feedback loop Escape release Wire front release (L1) 1) Lockout bar For wiring diagram see page 81 CET1 Closed-circuit current principle CET1-R-CR-H-0X-SH CET1-R-CR-H-0X-SH-C CET1-R-CR-H-0F-SH-C CET1-R-CR-H-0F-SH-C CET1-R-CR-CH-0X-SH CET1-R-CD-CH-0X-SH-1132 CET2 Open-circuit current principle CET2-R-CR-H-0X-SH CET2-R-CD-H-0X-SH CET2-R-CR-CH-0X-SH m 10 mm 3 m 10 mm 1) L1 = sleeve length; cable length = L1 + 1 m. Important: Handle must be ordered separately (see accessories page 112). E E For detailed information, enter the order number Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16 7

5 System family R CET.-R- -SH- with plug connector 23 (no L approval), with door monitoring output Order No./item Coding = unicode = multicode Ramp Teach-in input Feedback loop Escape release Wire front release (L1) 1) Lockout bar For wiring diagram see page 81 CET3 Closed-circuit current principle CET3-R-CR-H-0X-SH CET3-R-CR-H-0F-SH-C CET3-R-CR-H-0X-SH-C CET3-R-CR-H-0F-SH-C CET3-R-CR-H-0X-SH-C CET3-R-CR-H-0X-SH-C CET3-R-CR-H-0F-SH-C CET3-R-CR-H-0F-SH CET3-R-CR-H-0X-SH-C CET3-R-CR-H-0F-SH-C CET3-R-CR-CH-0X-SH CET3-R-CD-H-0F-SH CET4 Open-circuit current principle CET4-R-CR-H-0X-SH CET4-R-CR-H-0F-SH CET4-R-CR-CH-0X-SH mm 3 m 10 mm 3 m m 7 mm 7 mm 10 mm 7 mm 7 mm 1) L1 = sleeve length; cable length = L1 + 1 m. Important: Handle must be ordered separately (see accessories page 112). E E For detailed information, enter the order number ctuator Series Design Order No./item CES--BWK-0X CET--BWK-0X For detailed information, enter the order number the search box at 76 Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16

6 ccessories Type Version Connection cable with plug connectors 12 8 Page 93 Page 9 Connection cable with plug connectors Page 99/100 Connection material Female plug (for self-assembly) Page 101 Strapg plug/y-distributor 12 Page 96 Passive distribution module 12 Page 97 Bolts Bolts for housing design CET Page 107 Fixing material ounting plates Page 110 Safety screws Page 112 Lockout bar echanical key release iscellaneous accessories Emergency unlocking Cover Page 112 Double ramp Handle for wire front release Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16 77

7 System family R Dimension drawing With 2 plug connectors LED 2 LED 1 13,4 STTE DI uxiliary release 1 ±4 mm 74, 28 67,2 CET.-.-CR ,6 2 <1> 11 Order actuator CET--BWK-0X separately CET.-.-CD For 6 screw DIN 1207/ISO 4762 X2 () X1 () 4 8 With angle connectors Plunger with read head 10, 26, 23 With plug connector , 78 Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16

8 With escape release With lockout bar Basic position for escape release Release by pressing Ø 9, 1,2 60, With wire front release 10 30, 83 Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16 79

9 System family R 8 Terminal assignment D Wiring diagram to D Pin Designation Function B C D X 1.1 IB Enable input for channel 2 X 1.2 B Operating voltage R electronics, DC 24 V X 1.3 O Safety output, channel 1 X 1.4 OB Safety output, channel 2 X 1. OT onitoring output X 1.6 I Enable input for channel 1 X V B Operating voltage R electronics, DC 0 V X 1.8 RST Reset input X V C Operating voltage guard locking solenoid, DC 0 V X 2.2 X 2.3 LED 1 LED 1 red, freely configurable, DC 24 V LED 1 red, solenoid energized OT D Door monitoring output LED 1 LED 1 red, freely configurable, DC 24 V LED 2 LED 2 green, freely configurable, DC 24 V OT onitoring output X 2.4 C Operating voltage guard locking solenoid, DC 24 V X 2. J Version with teach-in input Y Version with feedback loop Version without feedback loop and without teach-in input FE Function earth Not used 80 Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16

10 23 19 E Wiring diagram E Pin Designation Function 23 E 1 C Operating voltage guard locking solenoid, DC 24 V 2 I Enable input for channel 1 3 IB Enable input for channel 2 4 O Safety output, channel 1 OB Safety output, channel 2 6 B Operating voltage R electronics, DC 24 V 7 RST Reset input 8 OT D onitoring output (only CET3-R and CET4-R) 9 Not used 10 OT onitoring output 11 Not used 12 FE Function earth J Version with teach-in input 13 Y Version with feedback loop - Version without feedback loop and without teach-in input 14 Not used 1 LED 1 LED 1 red, freely configurable, DC 24 V 16 LED 2 LED 2 green, freely configurable, DC 24 V 17 - Not used 18 0V C Operating voltage guard locking solenoid, DC 0 V 19 0V B Operating voltage R electronics, DC 0 V Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16 81

11 12 PVC PR Connection cables with plug connectors For the connection of: CES-P-C01-..-SB CES-P-C.2-..-SB CES-I-P- -SB CES-I-P- -SI CTP-..-P- -SII CTP-..-R- -SB CET.-P- -SI CET.-R- -SG Terminal plug not aligned. Cable outlet not defined For the device installation position shown the following applies: Cable outlet C (left) C Cable outlet (right) Version Cable outlet Order No./item Connection cable with female plug, flying lead, x 0.34 mm² m 10m C-12F0-0X034PV0, C-12F0-0X034PV10, PVC Extension, plug connectors at both ends for connection to decentralized peripheral equipment 20m m 10m 20m C-12F0-0X034PV20, C-12F0-0X034PV0, C-12F0-0X034PV10, C-12F0-0X034PV20, For detailed information, enter the order number 12 PR Connection cable with female plug, flying lead, x 0.2 mm² Extension, plug connectors at both ends for connection to decentralized peripheral equipment 10m 10m C C C-12F0-0X02P10, C-12F0-0X02P10, C-12F0-0X02P10, C-12F0-0X02P10, Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16 93

12 ccessories 12 PR Version Cable outlet Order No./item m C-12F0-0X034P0, Connection cable with female plug, flying lead, x 0.34 mm² 10m C-12F0-0X034P10, PR Extension, plug connectors at both ends for connection to decentralized peripheral equipment 20m 30m m 10m C-12F0-0X034P20, C-12F0-0X034P30, C-12F0-0X034P0, C-12F0-0X034P10, For detailed information, enter the order number 20m C-12F0-0X034P20, Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16

13 12 8 PVC PR Connection cables with plug connectors For the connection of: CES-P-C01-..-S CES-R-C01-..-S CES-R-C.2-..-S CES-I-R-.-S ESL- -R- -S CE-..-Y- -S CTP-..-P- -S CTP-..-R- -SB CET.-P- -S CET.-R- -SG STTE DI Terminal plug not aligned. Cable outlet not defined For the device installation position shown the following applies: Cable outlet C (left) C Cable outlet (right) Version Cable outlet Order No./item 12 8 PVC Connection cable with female plug, flying lead, 8 x 0.2 mm² m 10m 20m C-12F08-08X02PV0, C-12F08-08X02PV10, C-12F08-08X02PV20, m C-12F08-08X02PV30, m C-12F08-08X02P0, PR Connection cable with female plug, flying lead, 8 x 0.2 mm² Connection cable with female plug, flying lead, 8 x 0.2 mm² 10m 20m 30m C 10m C-12F08-08X02P10, C-12F08-08X02P20, C-12F08-08X02P30, C-12F08-08X02P10, C-12F08-08X02P10, For detailed information, enter the order number 20m C C-12F08-08X02P20, C-12F08-08X02P20, Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16 9

14 ccessories 12 R Strapg plug/y-distributors For the series connection of devices on the output family R For the connection of: CES-R-C01-..-S CES-R-C.2-..-S CES-I-R-.-S ESL- -R- -S CTP-L.-R- -SB CET.-R- -SG STTE DI Version Order no. 4 Strapg plug for R series connection with Y-distributors (male plug) R 8 8 1x Y-distributor 12 with connection cable 0,2m x 1m x Y-distributor 12 For detailed information, enter the order number x Not suitable for CTP! Instead please use a Y-distributor with connection cable (see above) 96 Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16

15 12 R Passive distribution module For the series connection of devices on the output family R For the connection of: CES-R-C01-..-S CES-R-C.2-..-S CES-I-R-.-S ESL- -R- -S CTP-L.-R- -SB CET.-R- -SG STTE DI Version Order no. 12 R 8 4 x 1x Passive distribution module C-DP-04-S Strapg plug for bypassing unused connections on the passive distribution module (male plug) C-SP-1-S For detailed information, enter the order number Dimension drawing and connection options 34, 22 Connection of function earth X X6 4,3 Connection se X1 X4 - Connection of R devices (CES-R, CET-R,...) or - Bypassing using strapg plug if connection is not used or - Connection of a further passive distribution module (important: only on X1) X Provision of the status signals for all R devices connected X6 Power supply for the R devices and transmission of the safety signals X X H4 X4 4,9 X4 LED X1-X4 green H3 H2 X3 X X3 X2 For details see table Strapg plug C-SP-1-S H1 X1 X1 X1 X6 Connection of a further passive distribution module X Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16 97

16 23 19 PR Connection cable with straight plug connector For the connection of: CE- -R- -SH CTP- -R- -SH CET.-R- -SH Version Order no./item 1,m C-23F19-19XDIFP01, m C-23F19-19XDIFP03, m C-23F19-19XDIFP06, PR Connection cable with female plug, flying lead 8m 10m 1m 20m C-23F19-19XDIFP08, C-23F19-19XDIFP08, C-23F19-19XDIFP1, C-23F19-19XDIFP20, For detailed information, enter the order number for the product in the search box at 2m C-23F19-19XDIFP2, m C-23F19-19XDIFP30, m C-23F19-19XDIFP40, Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16 99

17 ccessories PR Connection cable with angled plug connector For the connection of: CE- -R- -SH CTP- -R- -SH CET.-R- -SH For the device installation position shown the following applies: Cable outlet C (left) Cable outlet (right) C Order no./item Version C Cable outlet 1,m C-23F19-19XDIFP01, C-23F19-19XDIFP01, m C-23F19-19XDIFP03, C-23F19-19XDIFP03, PR Female connector angled with cable, halogen-free 6m 8m 10m 1m C-23F19-19XDIFP06, C-23F19-19XDIFP08, C-23F19-19XDIFP10, C-23F19-19XDIFP1, C-23F19-19XDIFP06, C-23F19-19XDIFP08, C-23F19-19XDIFP10, C-23F19-19XDIFP1, For detailed information, enter the order number 20m C-23F19-19XDIFP20, C-23F19-19XDIFP20, m C-23F19-19XDIFP2, C-23F19-19XDIFP2, Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16

18 ccessories Fixing material ounting sets/mounting plates Series se Order No./item C04 ounting set -SET-PP 2 x ounting set -SET-PPB 1 x 1 x 1 x For safety switch and actuator design C04 Set comprising: 2 x mounting plates For safety switch and actuator design C04 Set comprising: 1 x mounting plate 1 x angle mounting plate 1 x spacer SET-PP SET-PPB ounting bracket -B C40 ounting bracket -B For safety switches CE- -C40 For safety switches CE- -C B B For detailed information, enter the order number ngle mounting plate EP-SB For safety switches CTP EP-SB ounting plate EP-B2 CTP ounting plate EP-B1 For actuators CTP For actuators CTP and actuators CET EP-B EP-B1 ounting plate -P For safety switches CTP P Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16

19 ccessories iscellaneous accessories Safety screws Fixing material/screw size Safety screws, stainless steel 4 x 14 (small head) Safety screws, stainless steel 4 x 14 (large head) Safety screws, stainless steel 4 x 20 Safety screws, stainless steel x 10 Safety screws x 16 Safety screws x 2 Version/usage ctuators CES--BB, CES--BC Safety switches CES-..-C.2, actuators CES--BLN-.2 and actuators CTP (straight/angled) Safety switches CES-I-P- -C04 and actuators CES--BBN-C04- Safety switches CES-..-C01, actuators CES--BP and hinged actuators CTP (left/right) ctuators CES--BRN, CET--BWK and actuators -C40 Hinged actuators CTP (top/bottom) Packaging unit [qty.] Order no iscellaneous accessories C40 Designation se Version Order no Lockout bar For safety switches design C E-L-C echanical key release Replacement key Release For safety switches CTP For mechanical key release, identical locking Identical locking, incl. 2 keys Identical locking, key can only be removed in locked position, incl. 2 keys nique locking, incl. 2 keys keys, identical locking CTP For safety switches CTP Resetting Emergency unlocking For safety switches CTP Lead seal kit For emergency unlocking Wire front release Resetting, sheath length 2 m E-B-1-02,0-F (rope length 6 m) For safety switches CTP Resetting, sheath length 3 m (rope length 6 m) E-B-1-03,0-F Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16

20 CTP Designation se Version Order no Handle for wire front release For safety switches CTP Y-HDL Y-HDL Lockout bar For safety switches CTP Lockout bar For safety switches CET E-L-CET echanical key release For safety switches CET Identical locking, incl. 2 keys Replacement key Emergency unlocking For mechanical key release, identical locking 2 keys, identical locking For safety switches CET Latching in both positions CET Lead seal kit For emergency unlocking Cover Door hinge right For safety switches CET and actuators CET Door hinge left Cover For actuators CET C Double ramp For safety switches CET Handle for wire front release For safety switches CET Y-HDL Y-HDL Subject to technical modifications; no responsibility is accepted for the accuracy of this information /16 113

System family AP. Safety switch CET.-AP- With guard locking

System family AP. Safety switch CET.-AP- With guard locking System family P Safety switch ET.-P- With guard locking at. 4 PLe Safety switch with guard locking Locking force up to 600 N Metal housing Diagnostics via 4 LEDs Notice The device is only allowed to be

More information

Available coding options

Available coding options System family P Safety switch TP- -P- With guard locking at. 4 PLe 1) Safety switch with guard locking Locking force up to 2600 N Diagnostics via 3 LEDs PL e/category 4 Notice The device is only allowed

More information

Safety Switches CES-AR/CET-AR

Safety Switches CES-AR/CET-AR Non-contact safety switches CET-AR-... with guard locking and guard lock monitoring Safety switch with guard locking and integrated evaluation electronics Locking force up to 00 N Up to 0 switches in series

More information

Transponder-coded safety switches Interlocking devices and guard locking devices

Transponder-coded safety switches Interlocking devices and guard locking devices Transponder-coded safety switches Interlocking devices and guard locking devices EN Internationally successful the EUCHNER company Headquarters in Leinfelden-Echterdingen EUCHNER GmbH + Co. KG is a world-leading

More information

Non-Contact Safety System CES-AZ

Non-Contact Safety System CES-AZ , 0 M 8 8,, 7,,,, 0 0 7 0 7 Mounting plate CEM For read head CEM-A-LE0... and actuator CEM-A-BE0... Material stainless steel Mounting plate EMP-L-CEM0 For read head CEM-A-LE0... 9 8 0 8 M - x, 7 Mounting

More information

Transponder-coded. with guard locking

Transponder-coded. with guard locking Transponder-coded safety switch CTP with guard locking The safety switch CTP The new safety switch CTP combines the proven principle of operation of electromechanical safety switches with guard locking

More information

Safety Switches CES-AR/CET-AR

Safety Switches CES-AR/CET-AR CES-A-L XXXXXX Safety Switches Component overview for non-contact safety switches Connection cable Safety switch Actuator Bolt CES-A-BBA Page 1 CES-A-BCA Page 1 Page 10 CES-AR-C01-... Page 10 CES-A-BPA

More information

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC Non-contact safety system CES-FD- Evaluation of signals in the field Connection of CES read heads Connection to the ET200s and ET200pro Familiar EUCHNER AP interface Functional description Field evaluation

More information

Product Overview Safety Engineering electronic

Product Overview Safety Engineering electronic Product Overview Safety electronic EN Without guard locking Safety System Multifunctional Gate Box MGB With/Without guard With guard locking With guard locking locking Control module MGB-L0 MGB-L1/L2 MGB

More information

Non-Contact Safety System CES-AZ

Non-Contact Safety System CES-AZ Read head CET-AX-... Read head with guard locking and guard lock monitoring Up to category High locking forces up to 00 N Integrated transponder coding Metal housing Design and functionality With the read

More information

Operating Instructions

Operating Instructions Transponder-Coded Safety Switch With Guard Locking CET.-AR- (Unicode/Multicode) EN Contents 1. About this document... 4 1.1. Scope...4 1.2. Target group...4 1.3. Key to symbols...4 1.4. Supplementary documents...4

More information

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches HSA-DMC Magnetic Safety Switches Key features: Compact size and easy positioning. Combination with proprietary relay modules achieves safety category 4 (EN954-1). Compact size ( 16 51mm) Positioning for

More information

Versatile and safe. Transponder-coded safety systems CES

Versatile and safe. Transponder-coded safety systems CES Versatile and safe. Transponder-coded safety systems CES Transponder-coded safety systems CES The coded electronic safety systems CES are modern interlocking devices of type 4 for the protection of people,

More information

Transponder-coded safety systems with external evaluation

Transponder-coded safety systems with external evaluation Transponder-coded safety systems with external evaluation EN Internationally successful the EUCHNER company Headquarters in Leinfelden-Echterdingen EUCHNER GmbH + Co. KG is a world-leading company in the

More information

Presentation. EUCHNER Multifunctional Gate Box MGB

Presentation. EUCHNER Multifunctional Gate Box MGB Presentation EUCHNER Multifunctional Gate Box MGB Page 1 EUCHNER Multifunctional Gate Box MGB Guard locking / Interlocking Device Interlocking device MGB-L 0. Locking device MGB-L 1 Mechanical locking/

More information

More than safety. Product Overview. Safety Engineering

More than safety. Product Overview. Safety Engineering More than safety. Product Overview Safety Engineering Safety Engineering at a Glance Non-Contact Safety Systems Transponder Coding CES-A-C5 Safety system CES-A-A Safety system CES-AZ-A Approvals Safety

More information

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system The SMART With an innovative diagnostic system Actual size shown Very compact: small in size, flexible in use Very Smart: suitable for Industry 4.0 with its intelligent diagnostic system Cost Saving: four-wire

More information

Selection guide Accessories: Cable

Selection guide Accessories: Cable Selection guide Sensor technology accessories Selection guide Accessories: Cable Cable with socket for PSENmag Features Quantity Cable, M8, 4-pin Kabel/cable Cable, M8, 8-pin Straight, screw-on Angled,

More information

Safety Switches with AS-Interface

Safety Switches with AS-Interface EN DE Safety Switches with AS-Interface Internationally successful the EUCHNER company Headquarters in Leinfelden-Echterdingen EUCHNER GmbH + Co. KG is a world-leading company in the area of industrial

More information

Universal Tongue-Operated Safety Interlock Switch

Universal Tongue-Operated Safety Interlock Switch Rev. 12.07 C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1 UL and C-UL listed, B approved T12 Universal Tongue-Operated Safety Interlock Switch Strong and versatile the compact size of the strong,

More information

Connection of CET3-AR to safety relay PNOZ X3.10P

Connection of CET3-AR to safety relay PNOZ X3.10P Connection of CET3-AR to safety relay PNOZ X3.10P Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules used... 2 EUCHNER...

More information

Multifunctional Gate Box MGB

Multifunctional Gate Box MGB Multifunctional Gate Box MGB More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 98. Around the world the Swabian specialists

More information

Active face 57,5. Series Comment Version Order no. / item. Installation material 8-groove Bosch Installation material for CES-A-BSP

Active face 57,5. Series Comment Version Order no. / item. Installation material 8-groove Bosch Installation material for CES-A-BSP Actuator CES-A-BSP Optimized for aluminum profile mounting Actuator CES-A-BSP 18,1 Ø 5,2 10 6 5 R2 57,5 97,1 CES-A-BSP Please order installation material separately 104970 CES-A-BSP-104970 For Bosch profiles

More information

Safety Switches with AS-Interface

Safety Switches with AS-Interface Safety Switches with AS-Interface EN Internationally successful the EUCHNER company Headquarters in Leinfelden-Echterdingen EUCHNER GmbH + Co. KG is a world-leading company in the area of industrial safety

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts. Auxiliary Contacts

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts. Auxiliary Contacts Safety TLS- General 1-2-Opto-electronics 3-Interlock Logic Description The TLS- is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min TLS- General 1-2-Opto-electronics 3-Interlock Logic Description The TLS- is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated and

More information

TS 981 door control TS 981 Control panel with traffic management for DES. Approvals and certificates

TS 981 door control TS 981 Control panel with traffic management for DES. Approvals and certificates TS 98 door control Control panel with traffic management for GfA ELEKTROMATEN drives with DES digital limit switch Approvals and certificates TS 98 TS 98 / TS 98 FT Type test according to: DIN EN DIN EN

More information

SAFETY LOCKING DEVICES

SAFETY LOCKING DEVICES L200 Heavy-Duty L200 Safety Locking Device on a very large gate in a logistics operation with forklift traffic The L200 Safety Locking Device designed for highly demanding applications is predestined for

More information

Tongue Switches Trojan 5 & 6

Tongue Switches Trojan 5 & 6 Interlock Switches Description The Trojan family is a universal tongue (or key) actuated safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. The dual key

More information

Operating Instructions

Operating Instructions Transponder-Coded Safety Switch With Guard Locking CET.-AP- (Unicode/Multicode) EN Contents 1. About this document... 4 1.1. Scope...4 1.2. Target group...4 1.3. Key to symbols...4 1.4. Supplementary documents...4

More information

Operating Instructions

Operating Instructions AR Evaluation Unit CES-AR-AES-12 EN Contents 1. About this document... 4 1.1. Scope...4 1.2. Target group...4 1.3. Key to symbols...4 1.4. Supplementary documents...4 2. Correct use... 5 3. Exclusion of

More information

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches R Safety Interlock Switches CM Series CM For full product information, visit www.sti.com. Use the SpeedSPEC Code for quick access to the specific web page. Most Diverse and Flexible Line of Coded Magnetic

More information

More than safety. Operating Instructions Non-Contact Safety Switch with Guard Locking CET.-AR-...-AH-... (Unicode)

More than safety. Operating Instructions Non-Contact Safety Switch with Guard Locking CET.-AR-...-AH-... (Unicode) More than safety. Operating Instructions Non-Contact Safety Switch with Guard Locking CET.-AR-...-AH-... (Unicode) Contents Scope Correct use Possible combinations for CES components Exclusion of liability

More information

Connection of serial wired MGB-L1..-AR to Safety Relay MSR127TP

Connection of serial wired MGB-L1..-AR to Safety Relay MSR127TP Connection of serial wired MGB-L1..-AR to Safety Relay MSR127TP Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules

More information

Connection of serial wired CES-AR to safety relay ESM-BA..1 Content

Connection of serial wired CES-AR to safety relay ESM-BA..1 Content Connection of serial wired CES-AR to safety relay ESM-BA..1 Content Interlocking device according to EN ISO 14119... 2 Components/modules used... 2 EUCHNER... 2 Functional description... 3 General... 3

More information

Connection of CET4-AR to Siemens ET 200S

Connection of CET4-AR to Siemens ET 200S Connection of CET4-AR to Siemens ET 200S Content Guard locking power on applied spring released according to EN ISO 14119 (open-circuit current principle)... 2 Components/modules used... 2 EUCHNER... 2

More information

TS 970 door control TS 970 Automatic control panel for DES / NES limit switches. Approvals and certificates

TS 970 door control TS 970 Automatic control panel for DES / NES limit switches. Approvals and certificates TS 90 door control Automatic control panel for GfA ELEKTROMATEN drives with DES digital limit switch or NES mechanical limit switch Approvals and certificates TS 90 TS 90 Type test according to: DIN EN

More information

More than safety. Operating instructions Non-contact safety system CES-A-ABA-01/CES-A-ABA-01B (Unicode)

More than safety. Operating instructions Non-contact safety system CES-A-ABA-01/CES-A-ABA-01B (Unicode) More than safety. Operating instructions Non-contact safety system CES-A-ABA-01/CES-A-ABA-01B (Unicode) Contents Correct Use 3 Possible combinations for CES components 4 Exclusion of Liability and Warranty

More information

TS 959 door control TS 959 Hold-to-run control panel for DES / NES limit switches. Approvals and certificates

TS 959 door control TS 959 Hold-to-run control panel for DES / NES limit switches. Approvals and certificates TS 99 door control Hold-to-run control panel for GfA-ELEKTROMATEN drives with DES digital limit switch or NES mechanical limit switch Approvals and certificates TS 99 TS 99 Type test according to: DIN

More information

MSR178DP. Description. Features. Specifications

MSR178DP. Description. Features. Specifications MSR178DP Description The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, offdelay or single-pulse modes. It is used for applications

More information

Safety. Detection. Control. MAGNUS RFID ENG - REV

Safety. Detection. Control. MAGNUS RFID ENG - REV 03 2017 1 Next generation RFID safety sensor 03 2017 2 03 2017 3 Next generation sensors for machine safety RFID safety sensors PL e, SIL 3 The application of Magnus RFID sensors can be extremely wide

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - In automated systems, sensors and actuators must interact with one another functionally and safely. The necessary coordination is performed by the programmable Safety Controller. Unlike the MSI 100 controller,

More information

Phone: Fax: Web:

Phone: Fax: Web: In automated systems, sensors and actuators must interact with one another functionally and safely. The necessary coordination is performed by the programmable Safety Controller. Unlike the MSI 100 controller,

More information

Connection of serial wired CTP-L1..-AR to Safety Relay ESM-BA..1

Connection of serial wired CTP-L1..-AR to Safety Relay ESM-BA..1 Connection of serial wired CTP-L1..-AR to Safety Relay ESM-BA..1 Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules

More information

Tongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications.

Tongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications. 1-2 -Interlock Safety 4 Description The Trojan family is a universal tongue-operated (or key-operated) safety-interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards.

More information

3-6. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Interlock Switches Overview.

3-6. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Interlock Switches Overview. Safety Interlock Overview 1-2-Opto-electronics 3-Interlock Versatility Many safety switches allow the head of the switch to rotate, offering different options on how the switch can be operated and mounted

More information

More than safety. System Manual Safety System MGB-AR in combination with a locking module MGB-L1-AR-.../MGB-L2-AR-...

More than safety. System Manual Safety System MGB-AR in combination with a locking module MGB-L1-AR-.../MGB-L2-AR-... More than safety. System Manual Safety System MGB-AR in combination with a locking module MGB-L1-AR-.../MGB-L2-AR-... Contents Correct Use 3 Exclusion of Liability and Warranty 4 General Safety Instructions

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow

More information

07. har-link Interface Connectors

07. har-link Interface Connectors . Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

TS 971 door control Integrated radio. TS 971 Automatic control panel for DES / NES limit switches. Approvals and certificates

TS 971 door control Integrated radio. TS 971 Automatic control panel for DES / NES limit switches. Approvals and certificates TS door control Integrated radio Automatic control panel for GfA ELEKTROMATEN drives with DES digital limit switch or NES mechanical limit switch Approvals and certificates TS TS Type test according to:

More information

Datalogic - SG4-Body BIG muting

Datalogic - SG4-Body BIG muting products Machine/Safety Safety light barriers Body Datalogic - SG4-Body BIG muting Body protection (2, 3 and 4 beam), Type 4, PL e Advanced Muting functions integrated Range 0.5-60 m WWW.OEM.CO.UK, INFORMATION@UK.OEM.SE,

More information

3-14. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Tongue Switches Cadet 3.

3-14. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Tongue Switches Cadet 3. General 1-2-Opto-electronics 3-Interlock Description The Cadet 3 is a tongue-operated (or key-operated) safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards.

More information

INDUSTRY. Ongoing dialog. Communication at Industry 4.0 level

INDUSTRY. Ongoing dialog. Communication at Industry 4.0 level INDUSTRY Ongoing dialog Communication at Industry 4.0 level Safety switch CES-C07 There is more than meets the eye to EUCHNER s smallest safety switch. Its actual innovation is on the inside. The CES-C07

More information

More than safety. Operating Instructions Non-Contact Safety Switch with Guard Locking CET.-AP-... (from V 1.5.0)

More than safety. Operating Instructions Non-Contact Safety Switch with Guard Locking CET.-AP-... (from V 1.5.0) More than safety. Operating Instructions Non-Contact Safety Switch with Guard Locking CET.-AP-... (from V 1.5.0) Contents Scope 3 Correct use 3 Possible combinations for CES components 4 Exclusion of liability

More information

Temperature Switches

Temperature Switches ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,

More information

07. har-link INTERFACE CONNECTORS

07. har-link INTERFACE CONNECTORS . INTERFACE CONNECTORS The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

Magnetically Coded Safety Switches CMS

Magnetically Coded Safety Switches CMS Magnetically Coded Safety Switches CMS EN Internationally successful the EUCHNER company Headquarters in Leinfelden-Echterdingen EUCHNER GmbH + Co. KG is a world-leading company in the area of industrial

More information

Online data sheet. S30A-7021EK S3000 Anti Collision SAFETY LASER SCANNERS

Online data sheet. S30A-7021EK S3000 Anti Collision SAFETY LASER SCANNERS Online data sheet S30A-7021EK S3000 Anti Collision A B C D E F system plug not supplied with delivery Ordering information Type Part no. S30A-7021EK 1071544 Usage Can only be used in the EFI system network,

More information

Product Overview Safety Engineering electro-mechanical

Product Overview Safety Engineering electro-mechanical Product Overview Safety electro-mechanical EN Safety Enabling Switches Enabling switches ZSE/ZXE Enabling switches ZSA/ZSB Enabling switches ZSM 1) Approvals Features/specifi c advantages three-stage built-in

More information

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT SECTION 21 182 Safety Light Curtains Type: SLC-F Finger (14mm) FEATURES: Resolution: 14mm Protective height: 160mm to 1040mm Type 4 according to IEC61496-1 and -2 ORDERING INFORMATION: SALES OF BEAMS PROTECTIVE

More information

Safety Systems Safety Integrated

Safety Systems Safety Integrated 3SF3 Limit, interlock and cable-operated Overview It is possible to directly connect selected limited, interlock and cable-operated switches via AS-Interface with safety-oriented communication. In these

More information

Safety Switches with Separate Actuator, Metal Housing

Safety Switches with Separate Actuator, Metal Housing Selection table for safety switches SG Standard One actuating head made of metal M SR11 RC18 Thread M0x1.5 for cable glands 11-pin + PE 18-pin + PE Two contacts Four contacts NC, Standard M SR11 RC18 Two

More information

Connection of CET3-AR to Pilz PDP67

Connection of CET3-AR to Pilz PDP67 Connection of CET3-AR to Pilz PDP67 Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules used... 2 EUCHNER... 2 Other...

More information

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1. Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page

More information

SAFETY COMMAND DEVICES

SAFETY COMMAND DEVICES SAFETY COMMAND DEVICES ESB200, ESB210 E-Stop button Installation variant of the ESB200 Safety Command Device (without housing), e.g., in control panels on handling or tool machines for stopping dangerous

More information

Specifications. Functional Safety Data Note: For up-to-date information, visit Certifications.

Specifications. Functional Safety Data Note: For up-to-date information, visit  Certifications. Safety Non-Contact General 1-2-Opto-electronics 3-Interlock Logic Description When it comes to machine safety, Rockwell Automation knows that protection of personnel and equipment is your main concern.

More information

Connection of serial wired CTP-L1..-AR to Siemens ET 200S

Connection of serial wired CTP-L1..-AR to Siemens ET 200S Connection of serial wired CTP-L1..-AR to Siemens ET 200S Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules used...

More information

07. har-link Interface Connectors

07. har-link Interface Connectors . Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

Connection of MGB-L2..-AR to safety relay PNOZ X3.10P

Connection of MGB-L2..-AR to safety relay PNOZ X3.10P Connection of MGB-L2..-AR to safety relay PNOZ X3.10P Content Guard locking spring applied power on released according to EN ISO 14119 (open-circuit current principle)... 2 Components/modules used... 2

More information

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTR 55 Ex Diffuse reflection light scanner with background suppression Dimensioned drawing en 01-2011/05 50113748 1 khz 5 400mm 200mm with black-white error < 10% 10-30

More information

Connection of CET3-AR to Pilz PDP67

Connection of CET3-AR to Pilz PDP67 Connection of CET3-AR to Pilz PDP67 Content Guard locking spring applied power on released according to EN ISO 14119 (closed-circuit current principle)... 2 Components/modules used... 2 EUCHNER... 2 Other...

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF7 VF KEYF8 CTUTORS HED TYPE ND WORKING PRINCIPLE 96D 96E 98D locked actuator with energized locked

More information

3-6. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Interlock Switches Overview.

3-6. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Interlock Switches Overview. Safety Interlock Overview General 1-2-Opto-electronics 3-Interlock Versatility Many safety switches allow the head of the switch to rotate, offering different options on how the switch can be operated

More information

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.com

More information

RoHS. High shaft load capacity. Shock / vibration resistant

RoHS. High shaft load capacity. Shock / vibration resistant Due to their sturdy bearing construction in Safety-Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up

More information

Versatile Safety Interlock Switch with Guard Door Locking

Versatile Safety Interlock Switch with Guard Door Locking R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr Safety Tongue Cadet 3 General 1-2-Opto-electronics

More information

Safe switching and monitoring Non-Contact Safety Sensors

Safe switching and monitoring Non-Contact Safety Sensors Safe switching and monitoring Non-Contact Safety Sensors Electronic safety sensors are used to detect guard door closure. These sensors use noncontact operating principles (pulse echo or RFID) that limits

More information

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment) 25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The

More information

IEC Power Control Contactors and Contactor Assemblies

IEC Power Control Contactors and Contactor Assemblies IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,

More information

More than safety. Operating instructions Non-contact safety system CES-A-AEA-02B/CES-A-AEA-04B (Unicode)

More than safety. Operating instructions Non-contact safety system CES-A-AEA-02B/CES-A-AEA-04B (Unicode) More than safety. Operating instructions Non-contact safety system CES-A-AEA-02B/CES-A-AEA-04B (Unicode) Contents Correct Use 3 Possible combinations for CES components 4 Exclusion of Liability and Warranty

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv) Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface

More information

MGB. Multifunctional Gate Box MGB. How to find your

MGB. Multifunctional Gate Box MGB. How to find your EN DE EUCHNER GmbH + Co. KG Kohlhammerstraße 6 7077 LeinfeldenEchterdingen Germany Tel. +9 7 7597 0 Fax +9 7 756 info@euchner.de www.euchner.com How to find your MGB 0609050/ Subject to technical modifications

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Safety Interlock Switches TL8012-S TL8012 For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Versatile Safety Interlock

More information

Operating Instructions

Operating Instructions Operating Instructions Safety Systems MGB-L..B-PN.- (PROFINET) with Data Structure Type B from V3.30.0 EN Contents 1. About this document... 4 1.1. Scope...4 1.1.1. Notes on older product versions...4

More information

Safety Products Introduction LS-Titan Safety Interlock Switches. Technical Reference... 2

Safety Products Introduction LS-Titan Safety Interlock Switches. Technical Reference... 2 Key Interlock Switch Door-Flap Switch Door-Hinge Switch.0 Introduction Technical Reference............................................ 2.1 Learn Online Product Description.............................................

More information

Safety switches for hinged doors

Safety switches for hinged doors C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

Non-contact Machine Safeguarding with RFID Technology. LED offers diagnostics for switch status, margin alignment, and fault finding

Non-contact Machine Safeguarding with RFID Technology. LED offers diagnostics for switch status, margin alignment, and fault finding Interlock SensaGuard Non-Contact 440N RFID unique (high) or standard (low) coded actuators PLe Cat 4 per ISO 3849- (safety performance is maintained when connected in series) Flat pack and barrel (plastic

More information

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work

More information

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20

More information

Safety switches with separate actuator

Safety switches with separate actuator A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT

More information

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i SECTION 16 VIPER Safety Relays Type: SCR-i (with added diagnostics) SAFETY RELAY FUNCTION: IDEM s VIPER SCR-i range of Safety Relays have been designed in accordance with EN60204-1 for safety circuits

More information

Sensor Actuator Interface. Catalogue

Sensor Actuator Interface. Catalogue C T L O G U E 8 2011 2012 ensor ctuator Interface Catalogue CTLOGUE 8 ensor ctuator Interface Contents ensor ctuator Interface Introduction ensor and actuator cables Fieldbus, data cables and accessories

More information

Connection of MGB-L2..-AR to safety relay PNOZ s5

Connection of MGB-L2..-AR to safety relay PNOZ s5 Connection of MGB-L2..-AR to safety relay PNOZ s5 Content Guard locking power on applied spring released according to EN ISO 14119 (open-circuit current principle)... 2 Components/modules used... 2 EUCHNER...

More information

Safety switches with manual mechanical delay and separate actuator

Safety switches with manual mechanical delay and separate actuator D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.

More information

Compact Coded Magnetic Safety Interlock Switch and Control Units

Compact Coded Magnetic Safety Interlock Switch and Control Units C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch

More information

Connection of CES-AR to safety relay ESM-BA..1 Content

Connection of CES-AR to safety relay ESM-BA..1 Content Connection of CES-AR to safety relay ESM-BA..1 Content Interlocking device according to EN ISO 14119... 2 Components/modules used... 2 EUCHNER... 2 Functional description... 3 General... 3 Connections...

More information

Electronic pressure switch with display Model PSD-4

Electronic pressure switch with display Model PSD-4 Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine

More information

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18

More information