Dimensions for NPS 2 CL150 through 1500 Slip On Flange Connections
|
|
- Dora Little
- 6 years ago
- Views:
Transcription
1 Instruction Manual Supplement D03405X0 L, Le, and Lsj Controller pril 03 Dimensions for NPS CL50 through 500 Slip On Flange Connections Supplement to Fisher L, Le, and Lsj Level Controller Instruction Manuals This supplement contains dimensions for NPS CL50 through 500 slip on flange connections for L, Le, and Lsj level controllers. Refer to the Maintenance section of the appropriate instruction manual for instructions on removing the sensor from the controller, and disassembly of the sensor connector. Refer to the appropriate instruction manual for all other information regarding the L, Le, or Lsj level controller. L dimensions refer to figure and table Le dimensions refer to figure 3 and table Lsj dimensions refer to figure 4 and table 3
2 L, Le, and Lsj Controller pril 03 Instruction Manual Supplement D03405X0 Flange Orientation Orient the controller so that the case is level. See figure for the proper sensor orientation for flange welding. WRNING To maintain code/standard compliance, weld fabrication must meet the requirements of S ME Section IX. Failure to meet these requirement could result in personal injury and/or property damage. WRNING To maintain compliance with NCE MR075, weld fabrication must meet the requirements of NCE MR075, paragraph 5.3. Failure to meet these requirements could result in personal injury and/or property damage. Note Slip-on flanges are not supplied with the L, Le, or Lsj level controller. Contact your Emerson Process Management sales office for information on obtaining a slip-on flange construction. Figure. Sensor Orientation for Slip On Flange Mounting 45.5 FLNGE 0.5 FLNGE FCE OR HUB 8.64 (0.34) WIDTH CONNECTION 3 FLNGE SSEMBLY WITH 4 HOLE FLNGE NOTE RELTION OF TBS TO THE BOLT PTTERN FLNGE SSEMBLY WITH 8 HOLE FLNGE SECTION 34B503 C CONNECTION SHOULDER TO BOTTOM ON FLNGE HUB EXCEPT WHEN END TO FLNGE FCE IS LESS THN 8.64 (0.34 INCH) DIMENSION ONLY PPLIES WHEN CONNECTION CN BE INSERTED SUCH THT CONNECTION END TO FLNGE CONNECTION IS LESS THN 8.64 (0.34 INCH) 3 CONNECTION USED FOR ORIENTTION (INCH)
3 Instruction Manual Supplement D03405X0 L, Le, and Lsj Controller pril 03 Related Documents Bulletin 34.:L Fisher L Liquid Level Controller (D03034X0) Fisher L Liquid Level Controller Instruction Manual (D0303X0) Bulletin 34.:Le Fisher L Electric Level Controller (D0353X0) Fisher Le Electric Level Controller Instruction Manual (D0353X0) Bulletin 34.:Lsj Fisher Lsj Low Emission Liquid Level Controller (D039X0) Fisher Lsj Low Emission Liquid Level Controller Instruction Manual (D036X0) 3
4 L, Le, and Lsj Controller pril 03 Instruction Manual Supplement D03405X0 Figure. Fisher L Liquid Level Controller Dimensions with Slip On Flange (Refer to Table for Dimensions, B, and F) D 3 /4 8 NPT OUTPUT CONN B 48 (9.75) 55 (6.) 48 (.88) 30 (.88) F 9 (7.50) 30 (.88) 38 (.50) NSI FLNGE 05 (4.) /4 8 NPT SUPPLY CONN 4B (.88) FLNGED CONNECTION B F 4B8856 WELD PREPRTION FOR SLIP ON CONNECTIONS NOTES: DIMENSIONS ND D INCLUDE ONE STNDRD 6 INCH (5 ) EXTENSION. CONTCT YOUR EMERSON PROCESS MNGEMENT SLES OFFICE FOR OPTIONL EXTENSION LENGTHS. DIMENSIONS VLID WITH STNDRD DISPLCERS ONLY 3 DIMENSION D IS EQUL TO DIMENSION F PLUS 30 (.88 INCH) (INCH) 4
5 Instruction Manual Supplement D03405X0 L, Le, and Lsj Controller pril 03 Table. Fisher L Liquid Level Controller Dimension, B, and F (see figure ) 3 x 4 x 6 x NPS slip-on Connection SIZE ND RTING DIMENSIONS, B, ND F B F B F Inches CL50 RF CL300 RF CL600 RF CL600 RTJ CL900/500 RF CL900/500 RTJ CL50 RF CL300 RF CL600 RF CL600 RTJ CL900 RF CL900 RTJ CL500 FR CL500 RTJ CL50 RF CL300 RF CL600 RF CL600 RTJ CL900 RF CL900 RTJ CL500 RF CL500 RTJ CL50 RF CL300 RF CL600 RF CL600 RTJ CL900 RF CL900 RTJ CL500 RF CL500 RTJ Weld preparation
6 L, Le, and Lsj Controller pril 03 Instruction Manual Supplement D03405X0 Figure 3. Fisher Le Electric Level Controller Dimensions with Slip On Flange (Refer to Table for Dimensions, B, and F) 30 (.88) 3 6 (8.5) 48 (.88) 49 (5.87) 303 (.9) 30 (.88) 88 (3.46) 4 (5.60) GG (.88) FLNGED CONNECTION F GG3009- WELD PREPRTION FOR SLIP ON CONNECTIONS NOTES: DIMENSIONS ND D INCLUDE ONE STNDRD 6 INCH (5 ) EXTENSION. CONTCT YOUR EMERSON PROCESS MNGEMENT SLES OFFICE FOR OPTIONL EXTENSION LENGTHS. DIMENSIONS VLID WITH STNDRD DISPLCERS ONLY 3 DIMENSION D IS EQUL TO DIMENSION F PLUS 30 (.88 INCH) (INCH) 6
7 Instruction Manual Supplement D03405X0 L, Le, and Lsj Controller pril 03 Table. Fisher Le Electric Level Controller Dimension, B, and F (see figure 3) 3 x 4 x 6 x NPS slip-on Connection SIZE ND RTING DIMENSIONS, B, ND F B F B F Inches CL50 RF CL300 RF CL600 RF CL600 RTJ CL900/500 RF CL900/500 RTJ CL50 RF CL300 RF CL600 RF CL600 RTJ CL900 RF CL900 RTJ CL500 FR CL500 RTJ CL50 RF CL300 RF CL600 RF CL600 RTJ CL900 RF CL900 RTJ CL500 RF CL500 RTJ CL50 RF CL300 RF CL600 RF CL600 RTJ CL900 RF CL900 RTJ CL500 RF CL500 RTJ Weld preparation
8 L, Le, and Lsj Controller pril 03 Instruction Manual Supplement D03405X0 Figure 4. Fisher Lsj Liquid Level Controller Dimensions with Slip On Flange (Refer to Table 3 for Dimensions, B, and F) 76. (3.00) 5.4 (6.00) D 3 F /4 8 NPT OUTPUT CONN B 48 (9.75) 55 (6.) 9 (7.50) 7. (6.78) 5.4 (6.00) NSI FLNGE 05 (4.) /4 8 NPT SUPPLY CONN 76. (3.00) FLNGED CONNECTION B F 4B8856 WELD PREPRTION FOR SLIP ON CONNECTIONS NOTES: DIMENSIONS ND D INCLUDE ONE STNDRD 3 INCH (76. ) EXTENSION. CONTCT YOUR EMERSON PROCESS MNGEMENT SLES OFFICE FOR OPTIONL EXTENSION LENGTHS. DIMENSION VLID WITH STNDRD DISPLCERS ONLY 3 DIMENSION D IS EQUL TO DIMENSION F PLUS 5.4 (6.00 INCH) (INCH) 8
9 Instruction Manual Supplement D03405X0 L, Le, and Lsj Controller pril 03 Table 3. Fisher Lsj Liquid Level Controller Dimension, B, and F (see figure 4) 3 x 4 x 6 x NPS slip-on Connection SIZE ND RTING DIMENSIONS, B, ND F B F B F Inches CL50 RF CL300 RF CL600 RF CL600 RTJ CL900/500 RF CL900/500 RTJ CL50 RF CL300 RF CL600 RF CL600 RTJ CL900 RF CL900 RTJ CL500 FR CL500 RTJ CL50 RF CL300 RF CL600 RF CL600 RTJ CL900 RF CL900 RTJ CL500 RF CL500 RTJ CL50 RF CL300 RF CL600 RF CL600 RTJ CL900 RF CL900 RTJ CL500 RF CL500 RTJ Weld preparation
10 L, Le, and Lsj Controller pril 03 Instruction Manual Supplement D03405X0 Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher is a mark owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. ll other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. ll sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Marshalltown, Iowa 5058 US Sorocaba, 8087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United rab Emirates Singapore 846 Singapore , 03 Fisher Controls International LLC. ll rights reserved.
Supplement to Fisher FIELDVUE DVC6000 SIS Series Digital Valve Controllers for Safety Instrumented System (SIS) Solutions Instruction Manual
Instruction Manual Supplement D103395X012 DVC6000 SIS Supplement to Fisher FIELDVUE DVC6000 SIS Series Digital Valve Controllers for Safety Instrumented System (SIS) Solutions Instruction Manual Control
More informationConverting a Router DTM Installation to
September 2017 Converting a Router DTM Installation to ValveLink DTM (Obsolete Document) This document is OBSOLETE, as the procedure included within is no longer supported. Neither Emerson, Emerson Automation
More informationInstalling ValveLink DTM Software
Installation Guide ValveLink DTM Software Installing ValveLink DTM Software www.fisher.com ValveLink DTM Software Installation Guide ValveLink DTM Software Installation Guide This installation guide is
More informationFisher FIELDVUE DVC6200 HW2 Management of Change Guide
Fisher FIELDVUE DVC6200 HW2 Management of Change Guide www.fisher.com Table of Contents Background... 3 Management of Change... 3 Common Management of Change Checklist Question and Answer...3 FIELDVUE
More informationFIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers
Instruction Manual Supplement D103267X012 FIELDVUE Digital Valve Controllers Supplement to HART Communicating Fisher FIELDVUE Digital Valve Controller Instruction Manuals Using the HART Tri-Loop HART-to-Analog
More informationBaumann Little Scotty Bronze Control Valve
24000 Valve Product Bulletin Baumann 24000 Little Scotty Bronze Control Valve Baumann Little Scotty industrial control valves are intended for general utility service in pressure, flow, and temperature
More informationModule Definitions, IO Bytes, and Data Length for FIELDVUE DVC6200p PROFIBUS PA Digital Valve Controller
Instruction Manual Supplement DVC6200p s, IO Bytes, and Data Length for FIELDVUE DVC6200p PROFIBUS PA Digital Valve Controller Contents AO Module... AI Module... 8 DO Module... 9 DI Module... 10 A GSD
More informationFisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM
Instruction Manual Supplement Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM Contents Related Documents...
More informationFisher 657 and 667 Size 30i - 76i Diaphragm Actuators
657 and 667 Size 30i - 76i Product Bulletin August 2016 Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators Fisher 657 and 667, size 30i to 76i, spring-opposed diaphragm actuators position the valve
More informationAMS ValveLink Software Quick-Start Guide
Quick-Start Guide Form 5745 September 2006 AMS ValveLink Software Quick-Start Guide D102813X012 www.fisher.com FIELDVUE, PlantWeb, ValveLink, and Fisher are marks owned by Fisher Controls International
More informationScannerCal Accuracy Verification System for the FlowScanner
ScannerCal Product Bulletin ScannerCal Accuracy Verification System for the FlowScanner www.fisher.com Product Bulletin ScannerCal ScannerCal Accuracy Verification System Verify the calibration and accuracy
More informationHART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve
Instruction Manual Supplement DVC2000 Digital Valve Controller HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve Controller HART Revision Device Type Device Revision Firmware Revision
More informationFisher i2p-100 Electro-Pneumatic Transducer
i2p-100 Transducer Product Bulletin Fisher i2p-100 Electro-Pneumatic Transducer The Fisher i2p-100 electro-pneumatic transducer, uses a converter module that converts a milliampere input to a proportional
More informationFisher FIELDVUE DVC2000 Digital Valve
Product Bulletin D103167X012 DVC2000 Digital Valve Controller Fisher FIELDVUE DVC2000 Digital Valve Controller The FIELDVUE DVC2000 digital valve controller (see figure 1) is simple to use, compact, and
More informationType i2p-100 Electro-Pneumatic Transducer
Product Bulletin i2p-100 Transducer Type i2p-100 Electro-Pneumatic Transducer The Type i2p-100 electro-pneumatic transducer, shown in figure 1, uses a patented converter module that converts a milliampere
More informationDVC2000 Series FIELDVUE Digital Valve Controllers
Product Bulletin DVC2000 Series DVC2000 Series FIELDVUE Digital Valve Controllers The DVC2000 Series digital valve controller (see figure 1) is simple to use, compact, and designed for easy mounting. It
More informationKEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood TABLE OF CONTENTS 1 Optional module 13: 3-wires module... 1 2 Installation... 2 3 OM13 module setting and configuration... 8 4 OM13
More informationMALE THREAD SPECIFICATIONS
MALE THREAD SPECIFICATIONS PARALLEL MALE THREADS M20 Thread type BSP-m BSP-m BSP-m BSP-m Metric Seal method ISO 1179-4 ISO 1179-4 ISO 1179-4 ISO 1179-4 ISO 9974-3 Designation thread ISO 228-1 ISO 228-1
More informationFIELDVUE Instrumentation
Product Bulletin FIELDVUE Instrumentation Communicate with both HART and FOUNDATION Fieldbus FIELDVUE digital valve controllers Configure, calibrate, and diagnose FIELDVUE instruments from one location
More informationFisher FIELDVUE DVC2000 Digital Valve
DVC2000 Digital Valve Controller Product Bulletin Fisher FIELDVUE DVC2000 Digital Valve Controller The FIELDVUE DVC2000 digital valve controller is simple to use, compact, and designed for easy mounting.
More informationHART Field Device Specification Fisher FIELDVUE DVC6000 and DVC6200 HW1 Digital Valve Controllers
Instruction Manual Supplement DVC6000 Digital Valve Controller HART Field Device Specification Fisher FIELDVUE DVC6000 and DVC6200 HW1 Digital Valve Controllers Device Type Device Revision Firmware Revision
More informationHART Field Device Specification Fisher FIELDVUE DVC6200 SIS Digital Valve
Instruction Manual Supplement DVC6200 SIS Digital Valve Controller HART Field Device Specification Fisher FIELDVUE DVC6200 SIS Digital Valve Controller HART Revision Device Type Device Revision Firmware
More informationFisher i2p-100 Electro-Pneumatic Transducer
i2p-100 Transducer Product Bulletin Fisher i2p-100 Electro-Pneumatic Transducer The Fisher i2p-100 electro-pneumatic transducer, uses a converter module that converts a milliampere input to a proportional
More informationONLINE LICENSING PROCEDURE
375 Field Communicator 375 Field Communicator ONLINE LICENSING PROCEDURE Page 1 of 9 Online Licensing Procedure for the 375 Field Communicator Advantages of Online Licensing Allows users to add Licenses
More informationProbe Pendulum for Eddy- Current Sensors
PR647 Specifications Sheet Probe Pendulum for Eddy- Current Sensors The Probe Pendulum for eddy-current Sensors is designed for critical turbomachinery applications such as steam, gas and hydro turbines,
More informationFisher i2p-100 Electro-Pneumatic Transducer
Fisher i2p-100 Electro-Pneumatic Transducer The Fisher i2p-100 electro-pneumatic transducer, uses a converter module that converts a milliampere input to a proportional pressure output. Both the current
More informationControlWave Micro Analog Input / Output Modules
CWMICRO:AIO Product Data Sheet D301672X012 October 2011 ControlWave Micro Analog Input / Output Modules The Analog Input (AI), Analog Output (AO), and Analog Input/Output (AI/O) modules provide the ControlWave
More informationHART Field Device Specification Fisher FIELDVUE DVC5000 Digital Valve Controllers
Instruction Manual Supplement DVC5000 Digital Valve Controller HART Field Device Specification Fisher FIELDVUE DVC5000 Digital Valve Controllers HART Revision Device Type Device Revision Firmware Revision
More informationROC800L Field Conversion Guide
Form A6305 Part Number D301683X012 December 2010 ROC800L Field Conversion Guide Remote Automation Solutions Revision Tracking Sheet December 2010 This manual may be revised periodically to incorporate
More informationTEC2 LDM Programming Instructions
Programming Instructions TEC2 LDM Programming Instructions Using MPLAB IDE Software and MPLAB ICD3 Download Probe Programming Instructions Table of Contents Table of Contents Section 1: 1.1 Using MPLAB
More informationMI-2667 Annubar Flow Calculation Program
Flow Computer Division MI-2667 Annubar Flow Calculation Program (For the FloBoss 103) User Manual (QER 05Q038) D301833X012 Form A6194 October 2005 Revision Tracking Sheet October 2005 This manual may be
More informationControlWave PAC Resistance Temperature Detector Module and Thermocouple Module
CWPAC:TEMP Product Data Sheet D301717X012 October 2012 ControlWave PAC Resistance Temperature Detector Module and Thermocouple Module The Resistance Temperature Detector (RTD) module and the Thermocouple
More informationControlWave PAC Digital Input / Output Modules
CWPAC:DIO Product Data Sheet D301716X012 October 2012 ControlWave PAC Digital Input / Output Modules The Digital Input (DI), Digital Output (DO), and Digital Input/Output (DI/O) modules provide the ControlWave
More informationControlWave PAC Analog Input / Output Modules
CWPAC:AIO Product Data Sheet D301715X012 October 2012 ControlWave PAC Analog Input / Output Modules The Analog Input (AI), Analog Output (AO), and Analog Output (AO) with Read-Back modules provide the
More informationWirewound Resistors, Industrial Power, Silicone Coated, Adjustable Tubular
Wirewound Resistors, Industrial Power, Silicone oated, djustable Tubular FETURES High temperature silicone coating omplete welded construction Tight tolerance of 5 % for values above 1 Excellent stability
More informationNOTE: Reducing flanges are available in all types and pressures.
Flanges Types : Weld Flanges, Slip-On Flanges, Weld Flanges, Threaded Flanges, Flanges, Blind Flanges. 1/2" - 24" Class 150, 300, 400, 600, 900, 1500 and 2500 NOTE: Reducing flanges are available in all
More informationFOUNDATION Fieldbus Interface Software (for the ROC800-Series) User Manual
Form A6268 Part Number D301653X012 November 2009 FOUNDATION Fieldbus Interface Software (for the ROC800-Series) User Manual Remote Automation Solutions Revision Tracking Sheet November 2009 This manual
More informationControlWave Micro HART / BTI Interface Module
June 2009 ControlWave Micro HART / BTI Interface Module The HART (Highway Addressable Remote Transducer) / BTI (Bristol Transmitters) Interface Module is a plug-in I/O module allowing thecontrolwave Micro
More informationLineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation
LineGuard 2300 The LineGuard 2300 Electronic linebreak detection system monitors natural gas pipeline pressure and rate of pressure drop, and can provide manual or automatic control of a single valve actuator
More informationROC800-Series Thermocouple Module
ROC800:TC2 Product Data Sheet D301689X012 February 2012 ROC800-Series Thermocouple Module The Thermocouple (T/C) Input module provides the ROC800-Series Remote Operations Controller with Series 2 architecture
More informationBristol IStran. Product Data Document 1660DS-4a July 19, Page 1
July 19, 2007 - Page 1 The Intrinsically Safe transceiver, from Emerson Process Management, is the answer to your Class I, Div1 Certification needs and then some. General The following describes a typical
More information98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98
Series Back Pressure and Type Relief VL000 Valves FIELDVUE Valve Link Fisher Controls August Bulletin.: The Series (figure ) is used for back pressure or relief applications in liquid, gas, air, and steam
More informationFisher FIELDVUE DVC6000f Digital Valve Controllers (Supported)
Instruction Manual D103189X012 DVC6000 Digital Valve Controller September 2018 Fisher FIELDVUE DVC6000f Digital Valve Controllers (Supported) Contents Introduction... 1 Safety Instructions... 1 Specifications...
More informationLoading Configuration from TEC2000 to TEC2 using DCMLink. Configuration Instructions TEC2-LOAD-1001 Rev. 1 September 2015
Loading Configuration from TEC2000 to TEC2 using DCMLink Configuration Instructions Configuration Instructions Table of Contents Table of Contents Section 1: Configuration Instructions Using DCMLink Software
More informationType DH7091 Transient Protection Assembly
Type DH7091 Transient Protection Assembly D3P00801102 Installation Manual PN4.10:DH7091 Revision A June 1991 This manual supersedes the previous issue dated February 1990. In October 2001, company logos
More informationEdgewound Power Resistor
Edgewound Power Resistor FETURES Resistance-alloy ribbon wire is coiled on edge and supported on specially designed porcelain insulators Open coil construction allows efficient heat dissipation and easily
More informationControlWave Micro Resistance Temperature Detector Module and Thermocouple Module
CWMICRO:TEMP Product Data Sheet D301677X012 February 2012 ControlWave Micro Resistance Temperature Detector Module and Module The Resistance Temperature Detector (RTD) module and the (TC) module allow
More informationMicro Motion 7845/7847 Series Density and Concentration Meters
Product Data Sheet PS-001040, Rev. G pril 2009 Micro Motion 7845/7847 Series Density and Concentration Meters Micro Motion density and concentration meters are built to tackle the most demanding process
More informationREPLACEMENT PART REFERENCE GUIDE, ZGBDC10-362HP+ AN
REPLACEMENT PART REFERENCE GUIDE, ZGBDC1-362HP+ AN--12 ORIGINAL PART: ZGBDC1-362HP+ REPLACEMENT PART: ZGBDC1-372HP+ Part has been judged by Mini-Circuits Engineering as a suitable replacement to Parta
More informationV-Cone Metering Program
Flow Computer Division V-Cone Metering Program (For the FloBoss 103) User Manual (QER 03Q022) Form A6147 December 2005 Revision Tracking Sheet December 2005 This manual may be revised periodically to incorporate
More informationControlWave Micro Digital Input / Output Modules
May 2011 ControlWave Micro Digital Input / Output Modules The Digital Input (DI), Digital Output (DO), and Digital Input/Output (DI/O) modules provide the ControlWave Micro with the ability to monitor
More informationDeltaV M-series I/O Subsystem Horizontal Carriers
DeltaV Distributed Control System Product Data Sheet DeltaV M-series I/O Subsystem Horizontal Carriers The DeltaV modular I/O subsystem is easy to install and maintain. Modular design allows flexible installation
More informationV-Cone Metering Program (for the ROC800-Series) User Manual
Form A6149 Part Number D301193X012 October 2011 V-Cone Metering Program (for the ROC800-Series) User Manual Remote Automation Solutions Revision Tracking Sheet October 2011 This manual may be revised periodically
More informationREPLACEMENT PART REFERENCE GUIDE, ZGDC6-362HP+
REPLACEMENT PART REFERENCE GUIDE, ZGDC6-362HP+ AN--009 ORIGINAL PART: ZGDC6-362HP+ REPLACEMENT PART: ZGDC6-372HP+ Part has been judged by Mini-Circuits Engineering as a suitable replacement to Parta MECHANICAL
More informationSHEET 1 OF 14
Electronic Master PRINTED COPIES RE UNCONTROLLED Rosemount Proprietary REVISIONS REV DESCRIPTION CHG.NO. PP'D DTE REMOVED SNP-RING HOLDER DSI1002683 MH 06/24/09 NOTES: 1. 2. 3. 4. 5. 6. ROSEMOUNT INC.
More informationOracle Agile Product Lifecycle Management for Process Reporting User Guide Release E
Oracle Agile Product Lifecycle Management for Process Reporting User Guide Release 6.1.1.5 E57828-01 November 2014 Oracle Agile Product Lifecycle Management for Process Reporting User Guide, Release 6.1.1.5
More informationControlWave Micro Digital Input / Output Modules
CWMICRO:DIO Product Data Sheet D301675X012 February 2012 ControlWave Micro Digital Input / Output Modules The Digital Input (DI), Digital Output (DO), and Digital Input/Output (DI/O) modules provide the
More informationProbe Holder for PR6422 and PR6423
Probe Holder for PR6422 and PR6423 The probe holder permits mounting of eddy current sensors of type PR6422 and PR6423 at machines so that they can be adjusted form outside. The sensors can be changed
More informationNOTE 12 USB OPENING 'U' & 'UB' SERIES ONLY USB CAP NOT SHOWN NOTE 12 USB OPENING U & UB SERIES ONLY THIRD ANGLE PROJECTION DO NOT SCALE DRAWING
P80804(x) CONFIGURTIONS -S -U -UB -UBC -UBB -B -C P80804 COVER P80804 COVER w/usb OPENING P80804 COVER w/usb & BUTTON HOLE P80804 BSE P80804 BSE w/usb P80804 BUTTON P20603 CP 'UB' SERIES ONLY R E V I S
More informationControlWave Micro HART / BTI Interface Module
CWMICRO:HIM Product Data Sheet D301636X012 February 2012 ControlWave Micro HART / BTI Interface Module The HART (Highway Addressable Remote Transducer) / BTI (Bristol Transmitters) Interface Module is
More informationHytork XL Pneumatic Actuator
Hytork XL Pneumatic Actuator SIL Safety Manual SIL Safety Manual DOC.SILM.HXL.EN Rev. 0 May 2015 Hytork XL Series DOC.SILM.HXL.EN, Rev. 0 Table of Contents May 2015 Table of Contents Section 1: Functional
More informationBG-N13. Designed For The Nikon D5300 SLR Camera
BG-N13 BATTERY GRIP Designed For The Nikon D5300 SLR Camera Introduction Thank you for choosing Vello, and congratulations on your new BG-N13 battery grip purchase. Enjoy the many benefits that a battery
More informationRosemount 1595 Conditioning Orifice Plate
Rosemount 1595 Conditioning Orifice Plate Ordering information Rosemount 1595 Conditioning Orifice combines a flow conditioner with an orifice plate into a highly accurate primary element. Requires only
More informationSIL Safety Manual DOC.SILM.EF.EN Rev. 0 March EL-O-Matic F-Series Pneumatic Actuator SIL Safety Manual
SIL Safety Manual DOC.SILM.EF.EN Rev. 0 March 2015 EL-O-Matic F-Series Pneumatic Actuator SIL Safety Manual EL Matic TM EL-O-Matic F DOC.SILM.EF.EN, Rev. 0 Contents March 2015 Table of Contents Section
More informationThermocouple Technology, Inc.
Series E End Cap Series - Manufacturing Standard Valid only for Overall Length L maximum of 24" and/or one-piece construction barstock *NOTICE: TTEC provides a one piece construction machined barstock
More informationUSB-10PCHV2, USB-10PCHSV2 User Manual
USB-10PCHV2, USB-10PCHSV2 User Manual Thank you for choosing Xcellon. Xcellon Powered USB Hubs expand your computer s USB 3.0 port into ten ports. Seven USB 3.0 ports deliver SuperSpeed USB transfer rates
More informationwith External Springs
Two-Section Broadcast Arm with External Springs Owner s Manual Introduction Thank you for choosing the Auray two-section broadcast arm with external springs. This versatile and sturdy broadcast arm is
More informationDuctile Iron Flanged Fittings DIA. OF BOLT CIRCLE FLANGE THICKNESS 2" " "
-27 NOM. PIPE FLNGE O.D. DI. OF OLT CIRCLE JOINT DIMENSIONs (in inches) FLNGE THICKNESS OLT HOLE DIMETER NO. OF OLTS OLT DI. & LENGTH O.D..C. T 2" 6.00 4.75.62.750 4 5 8 2 1 4 3" 7.50 6.00.75.750 4 5 8
More informationWirewound Resistor, Industrial Power, Vitreous Coated, Fixed Tubular
Wirewound Resistor, Industrial Power, Vitreous Coated, Fixed Tubular FEATURES High temperature vitreous coating Complete welded construction Available in non-inductive style (special NI ) with Ayrton-Perry
More informationGeneral Specifications
General Specifications Model PR10 Inductive Conductivity Retractable fitting On-line measurements often present extra challenges, especially when routine maintenance is required. The PR10 is ideally suitable
More informationSTEVAL-SPBT4ATV3. USB dongle for the Bluetooth class 1 SPBT2632C1A.AT2 module. Features. Description
USB dongle for the Bluetooth class 1 SPBT2632C1A.AT2 module Features Based on V3.0 Bluetooth class 1 module, SPBT2632C1A.AT2 USB interface and power supply Supported reprogrammability via USB interface
More informationPrisma II Chassis 56-Port Upgrade Technical Bulletin
Prisma II Chassis 56-Port Upgrade Technical Bulletin Overview Audience Introduction This technical bulletin applies to all cable system operators and technicians who use the Prisma II Chassis configured
More informationOracle Retail MICROS Stores2 Functional Document Sales - Receipt List Screen Release September 2015
Oracle Retail MICROS Stores2 Functional Document Sales - Receipt List Screen Release 1.36 September 2015 Oracle Retail MICROS Stores2 Functional Document Sales - Receipt List Screen, Release 1.36 Copyright
More informationMEDIUM 3 AA - STANDARD SXX XXX
NOTES: UNLESS OTHERWISE SPECIFIED. CORNERS DRWN SHRP TO BE R.005 MXIMUM. 2. EXTERIOR SURFCE TEXTURE TO BE EDM FINISH. EQUIVLENT TO MT-020. TEXTURE ON ENCLOSURE WILL VRY FROM TIME TO TIME S THE TOOL WERS
More informationOracle Agile Product Lifecycle Management for Process Content Synchronization and Syndication User Guide Release E
Oracle Agile Product Lifecycle Management for Process Content Synchronization and Syndication User Guide Release 6.1.0.1 E27853-01 March 2012 Oracle Agile Product Lifecycle Management for Process Content
More informationRosemount 1595 Conditioning Orifice Plate
Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual 00809-0100-4828, Rev BA Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before
More informationSMP75. Trisil for telecom equipment protection. Features. Description. Applications. Benefits
Trisil for telecom equipment protection Features bidirectional crowbar protection voltage: 8 V low leakage current: I R = 2 µa max holding current: I H = 15 ma min repetitive peak pulse current: I PP =
More informationFast Control Response Requirement
DeltaV Distributed Control System White Paper October 2016 Fast Control Response Requirement This document describes how fast loop control is achieved by using FOUNDATION Fieldbus with Control in the Field.
More informationRecipe Calculation Survey. Materials Control. Copyright by: MICROS-FIDELIO GmbH Europadamm 2-6 D Neuss Date: August 21 st 2007.
Recipe Calculation Survey Materials Control Copyright by: MICROS-FIDELIO GmbH Europadamm 2-6 D - 41460 Neuss Date: August 21 st 2007 Page 1 of 8 Copyright 2015, Oracle and/or its affiliates. All rights
More informationUnit 5 Vocabulary. A function is a special relationship where each input has a single output.
MODULE 3 Terms Definition Picture/Exmple/Nottion 1 Function Nottion Function nottion is n efficient nd effective wy to write functions of ll types. This nottion llows you to identify the input vlue with
More informationEV-VNQ5E050AK VNQ5E050AK evaluation board
VNQ5E050AK evaluation board Data brief production data Features Parameter Symbol Value Unit Max supply voltage V CC 41 V Operating voltage range V CC 4.5 to 28 V Max On-State resistance R ON 50 mω Current
More informationPeopleSoft Fluid Required Fields Standards
ORACLE CORPORATION PeopleSoft Fluid Required Fields Standards Fluid User Experience November 2015 PeopleSoft Fluid Required Fields Standards Copyright 2015, Oracle and/or its affiliates. All rights reserved.
More informationOpenEnterprise Licensing User Manual
Form Number A6322 Part Number D301711X012 March 2012 OpenEnterprise Licensing User Manual Remote Automation Solutions Revision Tracking Sheet March 2012 This manual may be revised periodically to incorporate
More informationSafety manual for Fisher FIELDVUE DVC6200 SIS Digital Valve Controller, Position Monitor, and LCP200 Local Control Panel
Instruction Manual Supplement DVC6200 SIS Digital Valve Controller Safety manual for Fisher FIELDVUE DVC6200 SIS Digital Valve Controller, Position Monitor, and LCP200 Local Control Panel This supplement
More informationAUTOFOCUS LENS ADAPTER
AUTOFOCUS LENS ADAPTER User Manual LAE-SE-CEF Canon EF/EF-S Lens to Sony E-mount THANK YOU FOR CHOOSING VELLO The Vello Autofocus Lens Adapter allows for attachment of Canon EF and EF-S lenses to Sony
More informationVM-260 FLEXIBLE MACRO FLASH. User s Manual
Inspiration strikes VM-260 FLEXIBLE MACRO FLASH User s Manual Copyright 2017 Gradus Group. Bolt and other names of Bolt products are trademarks of Gradus Group. Other product and corporate names mentioned
More informationType 330SA High-Performance Electric Actuator
April 2000 Bulletin 61.5:330SA Type 330SA High-Performance Electric Actuator The Type 330SA High-Performance Electric Actuator (figure 1) is a high speed, high accuracy actuator that is suited for a wide
More informationMobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP207, Rev DB
Product Data Sheet February 2015 IP207, Rev DB Mobrey Squitch 2 Ultrasonic Liquid Level Switch A compact, self-contained, ultrasonic gap sensor, designed for switching in clean, non-aerated liquids BSPT
More informationAndroid Backdoor GhostCtrl can Silently Record Your Audio, Video, and More
Appendix Android Backdoor GhostCtrl can Silently Record Your Audio, Video, and More Appendix TrendLabs Security Intelligence Blog Lenart Bermejo, Jordan Pan, and Cedric Pernet July 2017 TREND MICRO LEGAL
More informationJD Edwards EnterpriseOne Licensing
JD Edwards EnterpriseOne Licensing Disabling Client Licensing for Various Tools Releases O R A C L E W H I T E P A P E R O C T O B E R 2 0 1 5 Disclaimer The following is intended to outline our general
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More information1N5221B - 1N5263B Zener Diodes
1N5-1N5 Zener Diodes Tolerance = 5% 1N5-1N5 Zener Diodes DO-35 Glass case COLOR BAND DENOTES CATHODE Absolute Maximum Ratings Stresses exceeding the absolute maximum ratings may damage the device. The
More informationDeltaV VerticalPlus I/O Subsystem Carriers
DeltaV Distributed Control System Product Data Sheet DeltaV VerticalPlus I/O Subsystem Carriers Designed for SIS Modular design allows flexible installation Allows you to expand online Increases I/O density
More information26-polige. Contacts Signalsteckverbinder. Circular Connectors
26-polige Contacts Signalsteckverbinder Circular Connectors 41 Ordering information 26 CONTCTS signal circular connectors ll standard connectors are published in this catalog. However, this catalog does
More informationProduct Bulletin BPS-100 Revision 2.1 November C l a m p P i p e C o n n e c t o r
Product Bulletin BPS-00 C l a m p P i p e C o n n e c t o r Table of Contents BlueSky Clamp Connector... Industrial Applications... Clamp Connector Description... How the Metal to Metal Seal Works... Design
More informationGH-30. Gimbal Head. You re on steady ground
GH-30 Gimbal Head You re on steady ground 1 INTRODUCTION Thank You for choosing Oben! The Oben GH-30 is a gimbal-type tripod head designed to balance a lens along its vertical and horizontal axes. The
More informationRAPID LENS CHANGER. User Manual
RAPID LENS CHANGER User Manual THANK YOU FOR CHOOSING VELLO The Vello Rapid Lens Changer offers speed, convenience, and flexibility to make you more efficient in the field. Freeing you from a bulky camera
More informationDRIVE DOCK. User Guide
DRIVE DOCK User Guide CONTENTS Introduction 1.1 Minimum System Requirements...1 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported Drives 1.2 Package Contents...1 1.3 About This Manual...1
More informationMACROFIER Reverse Mount and Extension Tube with Automatic Functionality for Canon EOS Lenses. User Manual
MACROFIER Reverse Mount and Extension Tube with Automatic Functionality for Canon EOS Lenses User Manual THANK YOU FOR CHOOSING VELLO Thank you for choosing the Vello Macrofier. This unique accessory allows
More informationRC-ZH5. Owner s Manual. Remote Control for Zoom H5 REC L R VOLUME. Remote Control for Zoom H5
RC-ZH5 Remote Control for Zoom H5 Owner s Manual REC L R VOLUME Remote Control for Zoom H5 Introduction Thank you for choosing Auray. The Auray RC-ZH5 is a wired remote control for the Zoom H5 Handy Recorder.
More information