PC Wiring System. e-con type is newly added! One-touch connection reduces wiring labor. Series PCW

Size: px
Start display at page:

Download "PC Wiring System. e-con type is newly added! One-touch connection reduces wiring labor. Series PCW"

Transcription

1 PC Wiring System Series PCW econ type is newly added! Onetouch connection reduces wiring labor. Branch unit offers commonality Branch unit separates each manufacturer s point Input/Output (I/O) into point common pin layout. Conversion to a common pin layout, allows connection of the pin to SMC manifold solenoid valves and other manufacturers relay terminals without restriction. Power can be supplied to the PLC I/O unit. Compatible branch units are available for each PLC manufacturer s I/O. Simple parallel wiring type Without time delay unlike serial transmission. Easy visual understanding at a glance, offering simple startup, debug and trouble shooting maintenance. Improved wiring efficiency and ease of operation Dedicated cable reduces wiringequivalent to a serial transmission system. Onetouch type connector offers standardized wiring to prevent incorrect connection and vastly improved operational efficiency.

2 revolutionary new wiring system... Compatible PLC Manufacturers OMRON Corporation Mitsubishi Electric Corporation Sharp Corporation KEYENCE CORPORTION inputs inputs outputs VDC Power supply Direct connected branch unit Note) pplicable econ type PLC manufacturers: OMRON Corporation, Mitsubishi Electric Corporation econ point branch unit (with cover) econ point unit (with cover) econ point unit (circuit board) point unit with econ econ

3 The PC wiring system simplifies wiring between a PLC and all types of connected equipment. PC Wiring System Series PCW Branch unit point unit with

4 Standardized pin layout Once point unit or branch unit is replaced, no further wiring/design is necessary. Company s PLC I/O card Connector pin assignment (pin layout) F E D C B 0 F E D C B 0 Change of PLC manufacturers (Company to Company B) Company B s PLC I/O card Connector pin assignment (pin layout) B D F 0 C E B D F 0 C E General purpose unit General purpose unit Terminal block layout Terminal block layout F E D C B 0 Terminal block layout B D F B D F F E D C B 0 requires alteration. 0 C E 0 C E Poor performance in maintenance. Wiring must be redesigned again. PC wiring point unit Terminal block layout Input device (sensor)/ output device (solenoid valve, etc.) to be connected. 0 B C D E F 0 B C D E F PC Wiring system brings common layout. doption of econ type eliminates the need for special tools and wire stripping. [Promoted or evaluated by] Mitsubishi Electric Corporation, OMRON Corporation, Fuji Electric Co., Ltd., Keyence Corporation, SUNX, nywire Corporation, NKE, Kuroda Precision Industries Ltd., M, MP, SMC Common unit can be used. Reduced spare parts enabling easier stock control. Input q Insert the electric cables into the cover. w Press with pliers. 0 seconds for cables. Input/output Elimination of branch unit The function of a branch unit is builtin a point unit, allowing reduction of the number of units. Output Series PCW econ specification PLC input/output Conventional Series PCW PLC input/output Branch unit Branch point unit (Green): Normal (Red): Reverse connection (Off): Unconnected point unit Reverse connection detection function Visual indication of incorrect wiring of power supply and power supply status is provided. color LED indication point unit point unit Each unit available with cover compatible with DIN rail mounting or as circuit board. With cover (DIN rail mount compatible) Circuit board type

5 PC Wiring /Series PCWEC (econ Type) P. P. 0 P. Circuit board type With cover (DIN rail mount) Circuit board type With cover (DIN rail mount) Circuit board type With cover (DIN rail mount) point branch I/O unit Unit with econ combines branch unit with point unit. point I/O unit point unit with econ allows common models used for both I/O units. point I/O unit point unit with econ allows common models used for both I/O units. Can use two point I/O units in a cascade connection. PC Wiring System /Series PCW P. P. P. Branch unit: PLC direct connected type Directly mounted on PLC I/O card. Branch unit Connected to PLC I/O card via connection cable. P. P. P. point branch unit Separates two of point I/O transmissions once those are separated from two of point I/O by the branch unit. point I/O unit Wired to PLC I/O card via connection cable and wires connecting equipment to the s. P. point output reduced common unit Wired to PLC I/O card via connection cable and wires connecting equipment to the s. Products with crossover common wires are available. point output reduced common unit Wires two of point I/O signals once separated by the branch unit to each connecting equipment via terminal block. Products with crossover common wires are available. point I/O unit Wires two of point I/O signals once separated by the branch unit to each connecting equipment via. DIN rail mount type and box mount types are available.

6 PC Wiring System econ Type Series PCWEC Common Specifications Rated voltage line Rated current Communication line Insulation resistance Withstand voltage Impact resistance Terminal block specifications Input/output CS0, CS connector CN0 to CNF mbient temperature Screw tightening torque (Phillips head screwdriver/flat head screwdriver) VDC 0. MΩ or more at 00 VDC 00 VC 00 m/s 0. to 0. Nm/0. to 0. Nm Wire stripping length (recommended) mm Connecting wire size WG to (0. to. mm ) Conforms to MILC0 econ to C econ connector No need for special tools and wire stripping. Weight Model PCWECZBM00 PCWECXBR00 PCWECYBR00 PCWECZBM0 PCWECXBR0 PCWECYBR0 PCWECZ00 PCWECZ0 PCWEC0Z00 PCWEC0Z0 Weight (g) q Insert the electric cables into the cover. Option (econ Connector) w Press with pliers. 0 seconds for cables. pc. ZSC ZSC ZSC Model 0 pcs./pack ZSCP ZSCP ZSCP WG No. Cross section of conductor WG to 0. to 0. mm Finished O.D. ø0. to ø.0 ø.0 to ø. ø. to ø. Cover color Red Yellow Orange Note) pplicability varies dependant on conductive construction, conductive material, and/or insulating material even resulting in inapplicable. Consult with SMC and manufacturer of connecting equipment.

7 DCV Series PCWEC Point Input/Output Branch Unit Dimensions Circuit board type Circuit board type ø. circuit board mounting hole IN MDE IN JPN 0 CSO CS B C D E F YMXF *S S 0 (.) With cover (DIN rail mount compatible) With cover (DIN rail mount compatible). IN DCV MDE IN JPN 0 CSO CS B C D E F YMXF *S S (.) (0). Models Input Output PCWECXBR00 PCWECYBR00 PCWECXBR0 PCWECYBR0 PCWECZBM00 PCWECZBM0 Refer to pages and about the circuit diagram. Note Circuit board type With cover (DIN rail mount compatible) Circuit board type With cover (DIN rail mount compatible)

8 Series PCWEC Circuit Diagram Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples. Refer to page 0 for details such as pin number or layout. PCWECXBR00 [pplicable PLC example: OMRON Corporation C00HID] PCWECXBR Input/output connector (CS0) Input/output connector (CS) 0 0 Green Red 0 B C D E F *S S VDC (S) 0 VDC INPUT CN0 CN CN CN CN CN CN CN CN CN CN CNB CNC CND CNE CNF Input connector PCWECYBR00 [pplicable PLC example: OMRON Corporation C00HOD] PCWECYBR Input/output connector (CS0) Input/output connector (CS) 0 0 Green Red 0 B C D E F *S S VDC (S) 0 VDC OUTPUT CN0 CN CN CN CN CN CN CN CN CN CN CNB CNC CND CNE CNF Output connector

9 PC Wiring System econ Type Series PCWEC Circuit Diagram Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples. Refer to page 0 for details such as pin number or layout. PCWECZBM00 [pplicable PLC example: Mitsubishi Electric Corporation SX, SY] PCWECZBM0 F E D C B 0 Input/output connector (CS0) Input/output connector (CS) 0 0 Green Red 0 B C D E F *S S VDC (S) CN0 0 VDC INPUT/OUTPUT CN CN CN CN CN CN CN CN CN CN Input/output connector CNB CNC CND CNE CNF

10 PCWECZ00 Series PCWEC Point Input/Output Unit Models Circuit board type PCWECZ00 PCWECZ0 Refer to the figure below for the circuit diagram. Dimensions Circuit board type Circuit board type With cover (DIN rail mount compatible) ø. circuit board mounting hole DCV MDE IN JPN YMXF 0 B C D E F *S S With cover (DIN rail mount compatible) 0 (.) With cover (DIN rail mount compatible). PCWECZ0 DCV MDE IN JPN YMXF 0 B C D E F *S S (.) (0). Circuit Diagram PCWECZ00 PCWECZ0 Input/output connector (CS0) Green Red F E D C B 0 B C D E F 0 *S S VDC (S) CN0 0 VDC INPUT/OUTPUT CN CN CN CN CN CN CN CN CN CN Input/output connector CNB CNC CND CNE CNF

11 Series PCWEC Point Input/Output Unit Models Circuit board type PCWEC0Z00 PCWEC0Z0 Refer to the figure below for the circuit diagram. Dimensions Circuit board type Circuit board type With cover (DIN rail mount compatible) ø. circuit board mounting hole CS0 CS DCV MDE IN JPN 0 YMXF *S S With cover (DIN rail mount compatible) 0 (.) With cover (DIN rail mount compatible). CS0 CS DCV MDE IN JPN 0 YMXF *S S... (.) (0). Circuit Diagram PCWEC0Z00 PCWEC0Z0 Input/output connector (CS0) Input/output connector (CS) Green Red VDC *S (S) CN0 CN CN CN CN CN CN CN 0VDC S INPUT/OUTPUT Input/output connector Connection CS0 CS XY0 to XY CS0 CS XY to XYF

12 PC Wiring System Series PCW Common Specifications Rated voltage line Rated current Communication line Insulation resistance Withstand voltage Impact resistance Terminal block Screw tightening torque Wire stripping length (recommended) Connecting wire size Cable Specifications Power terminal (Phillips screw driver/flat head screw driver) I/O terminal (Phillips screw driver/ Flat head screw driver) Power terminal I/O terminal Power terminal I/O terminal VDC 0. MΩ or more at 00 VDC 0. kv 00 m/s 0. to 0. Nm/0. to 0. Nm 0. to 0. Nm/0. to 0. Nm mm WG to (0. to. mm ) WG to (0. to mm ) PVC sheath Power lines WG0 (0, 0 cores) Brown Blue Flat cable WG Model With power lines PCW 0H PCW 0H Without power lines Flat cable Length Power lines 0 cores 0 cores 0 cores cores 0 cores WG ( wires/0. mm) 00 m roll WG0 ( wires/0. mm) Sheath O.D. 0. mm.0 mm. mm. mm.0 mm Note) The flat ribbon cable without power lines are not available from SMC. If required, please source locally from your preferred supplier.

13 Series PCW Branch Unit: PLC Direct Connected Type PLC connection PLC Can be directly mounted on PLC. Specifications Weight g mbient temperature to C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page. Dimensions. 0.. (.).. Models Input PCW0 Note ) PCW0 Output Circuit diagram PCW0 Page PCW0 Note ) Page Two pieces are required for points of input/output. Note ) Combine one piece each of PCW0 and PCW0 (the PLC connection side connectors are reversed). Note ) Combine one piece each of PCW0 and PCW0 (the PLC connection side connectors are reversed). Caution When removing a cable with connector, a PCW0T puller is required.

14 Series PCW Circuit Diagram Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples. Refer to page 0 for details such as pin number or layout. PCW0 [pplicable PLC example: OMRON Corporation C00HID] Input/output connector (CN0) B B B B B B B B B B0 B B B B B B B B B B0 0 0 B C D E F 0 B C D E F 0 C B F E D C B F E D Input/output connector (CN) Input/output connector (CN) PCW0 [pplicable PLC example: OMRON Corporation C00HOD] Input/output connector (CN0) B B B B B B B B B B0 B B B B B B B B B B0 0 0 B C D E F 0 B C D E F 0 C B F E D C B F E D Input/output connector (CN) Input/output connector (CN)

15 PC Wiring System Series PCW Circuit Diagram Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples. Refer to page 0 for details such as pin number or layout. PCW0 [pplicable PLC example: Mitsubishi Electric Corporation SX] Input/output connector (CN0) 0 0 B0 B B B B B B B B B B0 B B B B B B B B B 0 B C D E F 0 B C D E F C B F E D C B F E D Input/output connector (CN) Input/output connector (CN) PCW0 [pplicable PLC example: Mitsubishi Electric Corporation SY] Input/output connector (CN0) 0 0 B0 B B B B B B B B B B0 B B B B B B B B B 0 B C D E F 0 B C D E F C B F E D C B F E D Input/output connector (CN) Input/output connector (CN)

16 Series PCW Branch Unit: DIN Rail Mount Type PLC connection PLC Specifications Weight 0 g mbient temperature to 0 C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page. Connected to PLC via connection cable. Dimensions RS. OUT. (.). 0.. Refer to page 0 for the junction cable part number. Models Input PCW0 PCW0 PCW Two pieces are required for points of input/output. Output PCW0 PCW0 PCW0 Circuit diagram Page Page Page

17 PC Wiring System Series PCW Circuit Diagram Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples. Refer to page 0 for details such as pin number or layout. PCW0 [pplicable PLC example: OMRON Corporation C00HID] Input/output connector (CN0) B C D E F 0 B C D E F 0 F E D C B F E D C B Input/output connector (CN) Input/output connector (CN) PCW0 [pplicable PLC example: OMRON Corporation C00HOD] Input/output connector (CN0) B C D E F 0 B C D E F 0 F E D C B F E D C B Input/output connector (CN) Input/output connector (CN)

18 Series PCW Circuit Diagram Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples. Refer to page 0 for details such as pin number or layout. PCW0 [pplicable PLC example: Mitsubishi Electric Corporation SX] Input/output connector (CN0) B C D E F 0 B C D E F F E D C B F E D C B Input/output connector (CN) Input/output connector (CN) PCW0 [pplicable PLC example: Mitsubishi Electric Corporation SY] Input/output connector (CN0) B C D E F 0 B C D E F F E D C B F E D C B Input/output connector (CN) Input/output connector (CN)

19 PC Wiring System Series PCW Circuit Diagram Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples. Refer to page 0 for details such as pin number or layout. PCW [pplicable PLC example: Keyence Corporation KZCX] Input/output connector (CN0) B C D E F 0 B C D E F F E D C B F E D C B Input/output connector (CN) Input/output connector (CN) PCW0 [pplicable PLC example: Keyence Corporation KZCT] Input/output connector (CN0) B C D E F 0 B C D E F F E D C B F E D C B Input/output connector (CN) Input/output connector (CN)

20

21 0 Series PCW Point Input/Output Unit PLC connection PLC Specifications Weight 0 g mbient temperature to C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page. Connected to PLC via connection cable. Dimensions 0. (.) 0.. R S X/ 0 C H C H IN OUT. 0 B C D E F 0 B C D E F... (.). Refer to page 0 for the junction cable part number. Models Input PCW0 PCW PCW Two pieces are required for points of input/output. Output PCW0 PCW PCW Circuit diagram Page Page Page

22 Series PCW Circuit Diagram Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples. Refer to page 0 for details such as pin number or layout. PCW0 [pplicable PLC example: OMRON Corporation C00HID] Input/output connector Input PCW0 [pplicable PLC example: OMRON Corporation C00HOD] Input/output connector Output

23 PC Wiring System Series PCW Circuit Diagram Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples. Refer to page 0 for details such as pin number or layout. PCW [pplicable PLC example: Mitsubishi Electric Corporation SX] Input/output connector B C D E F 0 B C D E F Input PCW [pplicable PLC example: Mitsubishi Electric Corporation SY] Input/output connector B C D E F 0 B C D E F Output

24 Series PCW Circuit Diagram Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples. Refer to page 0 for details such as pin number or layout. PCW [pplicable PLC example: Keyence Corporation KZCX] Input/output connector Input PCW [pplicable PLC example: Keyence Corporation KZCT] Input/output connector Output

25 Series PCW Point Output Reduced Common Unit PLC connection PLC Specifications Weight mbient temperature 0 g to C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page. Connected to PLC via connection cable. Dimensions (.). OUT RS OD/00LP CH CH. Refer to page 0 for the junction cable part number (.). Models Output Circuit diagram PCW Page PCW Page PCW Page Two pieces are required for points of input/output.

26 Series PCW Circuit Diagram Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples. Refer to page 0 for details such as pin number or layout. PCW [pplicable PLC example: OMRON Corporation C00HOD] Input/output connector Output PCW [pplicable PLC example: Mitsubishi Electric Corporation SY] Input/output connector B C D E F 0 B C D E F Output

27 PC Wiring System Series PCW Circuit Diagram Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples. Refer to page 0 for details such as pin number or layout. PCW [pplicable PLC example: Keyence Corporation KZCT] Input/output connector Output

28

29 IN OUT CH IN OUT Series PCW Point Input/Output Unit Terminal Block: DIN Rail Mount Type Models Specifications Input Output PCW0 Circuit diagram PCW0 Page Dimensions Weight g mbient temperature to 0 C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page (.). Terminal Block: Box Mount Type Models Input Output PCW0 PCW0 Dimensions Circuit diagram Page Specifications Weight 0 g mbient temperature to 0 C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page.. x M x 0. x ø machined for bar ring Mounting hole 0 0. (.) () 0.. () x ø 0 x ø

30 Series PCW Circuit Diagram PCW0 Input/output connector B C D E F input PCW0 Input/output connector B C D E F output

31 PC Wiring System Series PCW Circuit Diagram PCW0 Input/output connector 0 0 Input/output connector B C D E F input PCW0 Input/output connector Input/output connector B C D E F output

32 Series PCW Point Output Reduced Common Unit Model Specifications Output PCW Weight 0 g Refer to the figure below about the circuit diagram. mbient temperature to 0 C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page. Dimensions (.).. (.) B C D E F Circuit Diagram PCW Input/output connector B C D E F Output

33 Series PCW Point Branch Unit Models Specifications Input Output PCWK000 PCWK000 Refer to the figure below about the circuit diagram. Weight 0 g mbient temperature to 0 C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page. Dimensions 0. Input/Output connector CNO.. CN CN Input/Output connector (.). 0.. Circuit Diagram PCWK000 Input/output connector 0 0 PCWK000 Input/output connector 0 0 F E D C B F E D C B B C D E F 0 B C D E F 0 0 Input connector 0 0 Input connector 0 0 Output connector 0 0 Output connector

34 00

35 Series PCW PC Wiring System Connector Cable For Connection of PLC Input/Output Card to PCW Unit PLC input/output card to PCW branch unit PLC input/output card to PCW point unit PCW 0 00 Symbol 0 0 line Symbol Nil N line Yes No Lead wire length Symbol Lead wire length 0. m m. m m m m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. Specifications Standard specifications For connection of PCW unit compatible with KEYENCE CORP. PLC I/O card (KZCX, KZCT) Specifications Dimensions Series PCW0 With power lines PLC connection side PCW unit connection side Without power lines PLC connection side PCW unit connection side FCN manufactured by FUJITSU LIMITED 0 pin connector MILC0 0 pin connector FCN manufactured by FUJITSU LIMITED 0 pin connector MILC0 0 pin connector Series PCW0 With power lines PLC connection side PCW unit connection side Without power lines PLC connection side PCW unit connection side MILC0 pin connector MILC0 pin connector MILC0 pin connector MILC0 pin connector 0

36 Series PCW PC Wiring System Connector Cable Branch Unit: Connection of PLC Direct Connecting Type to PCW Unit Branch unit: Connection of PLC direct connecting type to PCW point unit Branch unit: Connection of PLC direct connecting type to PCW point unit Branch Unit: Connection of PLC Direct Connecting Type to Manifold Solenoid Valves Branch unit: Connection of PLC direct connecting type to manifold solenoid valves PCW 0 00 PCW 0 V 00 Dimensions Lead wire length Symbol lines Symbol Nil N lines Yes No Lead wire length 0. m m. m m m m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. Dimensions lines Symbol V N Lead wire length Symbol Power supply lines Yes No Lead wire length 0. m m. m m m m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. pplicable manifold solenoid valve kit G kit J kit Refer to Best Pneumatics No. for details regarding applicable manifold solenoid valves. With power lines Branch unit: PLC direct connecting type connection side JMS manufactured by IDEC Corporation 0 pin connector PCW unit connection side MILC0 0 pin connector With power lines Branch unit: PLC direct connecting type connection side JMS manufactured by IDEC Corporation 0 pin connector Manifold solenoid valve connection side (G kit) MILC0 0 pin connector Without power lines Branch unit: PLC direct connecting type connection side JMS manufactured by IDEC Corporation 0 pin connector PCW unit connection side MILC0 0 pin connector Without power lines Branch unit: PLC direct connecting type connection side JMS manufactured by IDEC Corporation 0 pin connector Manifold solenoid valve connection side (J kit) MILC0 0 pin connector 0

37 Series PCW PC Wiring System Connector Cable Connection of PCW Unit to PCW Unit Connection of PCW branch unit to PCW point unit Connection of PCW branch unit to PCW point unit Connection of PCW point unit to PCW point unit Connection of PCW Unit to Manifold Solenoid Valves Connection of PCW branch unit to manifold solenoid valves Connection of PCW point unit to manifold solenoid valves PCW 0 00 PCW 0 V 00 Lead wire length Symbol lines Symbol Nil N lines Yes No Lead wire length 0. m m. m m m m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. Symbol V N Lead wire length Symbol Lead wire length m 00 m 0. m 00 m 00 m 00 m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. lines Power supply lines Yes No pplicable manifold solenoid valve kit G kit J kit Refer to Best Pneumatics No. for details regarding applicable manifold solenoid valves. Dimensions With power lines PCW unit connection side PCW unit connection side Dimensions With power lines Manifold solenoid valve connection side PCW unit connection side (G kit) MILC0 0 pin connector MILC0 0 pin connector MILC0 0 pin connector MILC0 0 pin connector PCW unit connection side Without power lines PCW unit connection side Without power lines Manifold solenoid valve connection side PCW unit connection side (J kit) MILC0 0 pin connector MILC0 0 pin connector MILC0 0 pin connector MILC0 0 pin connector 0

38 Series PCW Circuit Diagram Instructions These are indicating addresses on the PLC I/O card. However indications vary dependant on each PLC, in this catalog, our common indications are as follows: th point address out of point F th point address out of point To CS (Connected to sensor, solenoid valve) F E D C B 0 Input/output connector (CS0) F E D C B 0 Numbers on the input/output connector indicate pin number of the connector itself. s pin assignment (pin layout) varies depending on each PLC I/O card, refer to the Circuit Diagram of this product and pin assignment of PLC I/O card when selecting. To CS (Connected to sensor, solenoid valve) Connector side to be connected to PLC (0pin connector) CS0 To wire the power supply: Connect V to () and G to () using the power cable and connector, or alternatively wire using your own cable. This connection offers VDC power supply to each equipment. Power supply terminal block CS CS Power supply terminal block Side to be connected to input/output equipment (0pin connector) These are indicating addresses on the PLC I/O card However indications vary dependant on each PLC, in this catalog, our common indications are as follows: nd address out of F th address out of To CS0 (Connected to PLC) F E D 0 C B 0 0 You can use this by connecting to the PCW unit together with the input/output unit, or by directly connecting to the manifold solenoid valve. Input/output connector (CN) 0

39 Series PCW PC Wiring System Precautions Be sure to read before handling. Refer to back page for Safety Instructions. Warning Operation. This product is intended for use in general F equipment. void using this product in machinery or equipment which directly affects human lives or where malfunction or failure can cause extended damage.. Do not disassemble this product for repair or rebuilding. Mounting, djustment & Wiring Caution. Do not drop or bump. Do not drop, bump or apply excessive impacts (00 m/s or more) during handling. The PC wiring system unit can be damaged and connected equipment may malfunction.. Be careful of incorrect wiring. Incorrect wiring may result in damage to connected equipment. The power supply will be short circuited if inputs and outputs are connected incorrectly for the point/ point input/output units following a branch unit.. Do not wire with power lines or high voltage lines. To prevent the intrusion of noise and surge from power and high voltage lines into signal lines, perform wiring for the PC wiring system separately (separate conduits) from power lines and high voltage lines.. Confirm proper insulation of wiring. Faulty insulation (crossed wiring, insulation defects between terminals, etc.) may result in damage to connected equipment, due to the application of excessive voltage or current flowing to the equipment.. Tighten screws with the proper tightening torque. If tightened beyond the tightening torque range, the terminal block and screws may be damaged.. void subjecting cables to repeated bending or pulling forces. Wiring installations which result in repeated bending stress and pulling force on cables can cause broken wires.. Note that the disposition of I/O addresses differs for each PLC manufacturer. General purpose label sets (applicable to all manufacturers) are included, which can be cut as needed and inserted into the terminal label holders.. Operate within the rated current. The maximum current capacity for the power supply line on circuit boards of all units is.0. If the current passing through units such as the branch unit and input/output unit exceeds.0, connect the power supply line to the same power supply terminal and do not allow current to pass through the circuit board. Caution. Confirm the specifications. Use properly after confirming the specifications. Operation outside the range of specifications (voltage, ambient temperature, impact, etc.) can cause damage, malfunction or fire.. Ensure sufficient clearance for maintenance activities. When designing an application, be sure to allow sufficient clearance for maintenance and inspections. Caution Caution Design & Selection Operating Environment. bsolutely do not use in an atmosphere with explosive gas. The PC wiring system is not an explosionproof construction. Never use in an atmosphere with an explosive gas since this may cause a serious explosion.. Do not use in an environment with temperature cycles. Temperature cycles other than found with normal temperature changes may adversely affect the PC wiring system unit.. Do not use in an area where surges are generated. If there are devices or equipment that generate large surges (magnetic lifter, highfrequency induction furnace, motor, etc.) near the connected equipment or PC wiring system unit, the connected equipment may deteriorate or be damaged. Consider appropriate measures for any source of power surges and take care with crossed lines.. Keep wire scraps and other extraneous material from getting inside this product. This can cause fire, failure or malfunction, etc. Keep wire scraps and other extraneous material from getting inside this product.. Use with consideration for an operating environment with a protective structure. void using the PC wiring system unit where water or oil is splashed. Maintenance & Inspection. To prevent unintended malfunctioning, perform maintenance regularly. Unintended malfunctioning and misoperation may result in an inability to ensure safety.. Do not touch the terminals or internal boards when current is being suplied. Touching terminals or internal boards when current is being suplied may result in malfunctioning or damage with the PC wiring system unit or connected equipment, or electric shock. 0

40 Series PCW PC Wiring System Precautions Be sure to read before handling. Refer to back page for Safety Instructions. Warning. Only the output specification unit can be selected when combining each unit of Series PCW and Series PCWEC. Please note: If an input specification unit is used, this may cause damage and/or possible burnout of any connected equipment. When used for PLC output card PLC output card Design & Selection econ type point branch unit point output unit PLC output card Output branch unit econ type point unit point output unit When used for PLC input card PLC input card econ type point branch unit point input unit PLC input card Input branch unit econ type point unit point input unit 0

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit Fieldbus system DeviceNet Compatible GW unit Operation Manual EX50-GDN URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8-507-89 Fax: +8-598-56 Note: Specifications

More information

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536

More information

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend. Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Discontinued WIRING SYSTEM INDEX VALVES GENERAL CATALOG. Caution PC WIRING SYSTEM

Discontinued WIRING SYSTEM INDEX VALVES GENERAL CATALOG. Caution PC WIRING SYSTEM VALVES GENERAL CATALOG WIRING SYSTEM INDEX Features 985 Wide Variation Units 987 Application Examples 989 Connection Examples 990 Features of Branch Units 991 Features of Terminal Blocks 992 Handling Instructions

More information

Doc. No.: EX**-OMC0024. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1 SMC CORPORATION

Doc. No.: EX**-OMC0024. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1 SMC CORPORATION Doc. No.: EX**-OMC00 Instruction Manual SI Unit / DI Unit EX0-SDN EX0-IE SMC CORPORATION SAFETY INSTRUCTIONS (Read carefully before use.) Thoroughly read this technical instruction manual and related manuals

More information

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations 875 PHOTO PHOTO IT FOW PARTICUAR Compact Inductive Proximity Sensor -separated GA- SERIES General terms and conditions... F-7 Related Information Glossary of terms... P.482~ Sensor selection guide... P.80~

More information

S8VE (60/90/120/180/240-W Models)

S8VE (60/90/120/180/240-W Models) Switch Mode Power Supply S8VE (60/90/120/180/240-W Models) CSM_S8VE_DS_E_1_1 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1,

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Industrial Control Relays Relays and terminal module RS type

Industrial Control Relays Relays and terminal module RS type Relaysandterminal module Relays-and-terminal module RS, N A very compact, space-saving terminal module containing four or six relays with one NO contact. Features The RS series relays-and-terminal module

More information

DC I/O Conversion Module FA-TB32XY

DC I/O Conversion Module FA-TB32XY DC I/O Conversion Module FA-TB32XY User's Manual Thank you for purchasing FA Goods product. Before using, please read this User s Manual and the relevant manuals carefully to ensure correct use. SAFETY

More information

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability 82 PHOTO PHOTO Compact Inductive Proximity Sensor -separated GA- SERIES General terms and conditions... F-7 Related Information Glossary of terms... P.86~ Sensor selection guide... P.757~ General precautions...

More information

One step ahead in performance and mounting ease

One step ahead in performance and mounting ease 95 Micro Photoelectric Amplifier Built-in PM-5 SERIES PM-45 SERIES PM-5 SERIES General terms and conditions... F- guide... P.9~ Related Information Glossary of terms / General precautions...p.1549~ / P.155~

More information

DC I/O Conversion Module

DC I/O Conversion Module DC I/O Conversion Module,FA-TB32XYH User's Manual Thank you for purchasing FA Goods product. Before using, please read this User s Manual and the relevant manuals carefully to ensure correct use. SAFETY

More information

EX120/121/122 Series Some protocols are not CE-compliant.

EX120/121/122 Series Some protocols are not CE-compliant. Output type for solenoid valves (For Output) EX120/121/122 Series Compatible Protocols CompoBus/S NKE Corp.: Fieldbus H System Made to Order Small unit compatible with a maximum of 16 outputs Compatible

More information

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- - Sealed Miniature Basic Switch Sealed Miniature Basic Switch Conforms to IP67 (Molded Lead Wire Type Only) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

Reduced wiring system. PROFIBUS-DP Compatible GW unit. Operation Manual EX510-GPR1. URLhttp://www.smcworld.com

Reduced wiring system. PROFIBUS-DP Compatible GW unit. Operation Manual EX510-GPR1. URLhttp://www.smcworld.com Reduced wiring system PROFIBUS-DP Compatible GW unit Operation Manual EX510-GPR1 URLhttp://www.smcworld.com 1 Table of Contents Thank you for purchasing the SMC reduced wiring system EX510 series. Please

More information

Series EX120/121/122. Integrated Type/For Output. How to Order SI Unit SV1000/2000/3000/4000 SY3000/5000 SY3000/5000 VQ1000/2000.

Series EX120/121/122. Integrated Type/For Output. How to Order SI Unit SV1000/2000/3000/4000 SY3000/5000 SY3000/5000 VQ1000/2000. Integrated Type/For Output Series EX120/121/122 Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks Series EX120 SV1000/2000/3000/4000 Series EX121 SY3000/5000

More information

4 Axis Step Motor Controller

4 Axis Step Motor Controller INFORMATION 4 Axis Step Motor Controller (Parallel I/O) RoHS V 4 axis synchronous control V Linear/circular interpolation Linear interpolation 50 Circular interpolation 50 Target position Axis 0 Target

More information

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD To power supply Stepper Motor Driver LCD Electric Actuator Series LCC Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

2. Actuator B: Ball type P: Pin type F: Flat type

2. Actuator B: Ball type P: Pin type F: Flat type Contact Displacement Sensor Built-in Amplifier Ensures Ease of Use and Saves Wiring Effort. Sensor Operates with a Low Force in a Wide Range of Applications. H Works with a low operating force (30 gf)

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

Cylindrical Proximity Sensor

Cylindrical Proximity Sensor Cylindrical Proximity Sensor A New Series of Easy-to-use and Tough Models with a Yellow Indicator New series of TL-X2C1-GE models with improved performance over the previous TL-X-E models. Also, in addition

More information

YAMAHA Robot Controller. MRCH/QRCH/QRCX Series UNIT OWNER'S MANUAL

YAMAHA Robot Controller. MRCH/QRCH/QRCX Series UNIT OWNER'S MANUAL YAMAHA Robot Controller MRCH/QRCH/QRCX Series UNIT OWNER'S MANUAL Safety Precautions (Always read before starting use) Always read this manual, the robot controller instruction manual and programming manual

More information

For Output. Series EX120/121/122. Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks

For Output. Series EX120/121/122. Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks D D D D D D For Output Series EX120/121/122 Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks Series EX120 Series EX121 Series EX122 SV1000/2000/3000/4000

More information

Cable specifications PVC

Cable specifications PVC IO-Link Proximity Sensor (Spatter-resistant Models) EEQ-@-IL@ IO-Link Makes Sensor Level Information Visible and Solves the hree Major Issues at Manufacturing Sites! A Proximity Sensor hat Can Be Used

More information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information Chemical-resistant Proximity Sensor E2KQ-X CSM_E2KQ-X_DS_E_4_3 Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster Excellent resistance against chemicals and oil with fluororesincoated case.

More information

EtherNet/IP TM SI unit

EtherNet/IP TM SI unit EX##-####### PRODUCT NAME EtherNet/IP TM SI unit MODEL / Series / Product Number UIUSP-SEN#-DUO02979 Contents Safety Instructions 2 How to Order 7 Summary of Product elements 8 Installation and Cabling

More information

EX12 -SCS1 EX12 -SCS2 EX12 -SSL1. SSL1: 0/16 SSL2: 0/8 Not provided 11 to 25 VDC 15 to 30 VDC 14 to 26.4 VDC 24 VDC+10%/ 5% 24 VDC+10%/ 5%

EX12 -SCS1 EX12 -SCS2 EX12 -SSL1. SSL1: 0/16 SSL2: 0/8 Not provided 11 to 25 VDC 15 to 30 VDC 14 to 26.4 VDC 24 VDC+10%/ 5% 24 VDC+10%/ 5% D D D D D D For Output Series EX120/121/122 Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks Series EX120 Series EX121 Series EX122 SV1000/2000/3000/4000

More information

Dimension A. Dimension B

Dimension A. Dimension B Slim Connector-Terminal lock Conversion Units CSM DS_E_2_3 New Slim Connector-Terminal lock Conversion Units. Mounting area reduced by 35% (in comparison with 40-pole XW2 Units) to contribute to downsizing

More information

S82S (3/7.5-W Models)

S82S (3/7.5-W Models) Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC

More information

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs 1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector

More information

Package Contents. GP Options (Made by Digital)

Package Contents. GP Options (Made by Digital) When connecting the power cord terminals to the GP, be sure the cord has first been unplugged from the power outlet to prevent the possibility of an electric shock. With the exception of changing the GP's

More information

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable 44 Connector Built-in Micro Photoelectric SERIES Related Information General terms and conditions... F-1 Glossary of terms... P.1~ selection guide... P.441~ General precautions... P.140 Amplifier Built-in

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend. Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European

More information

Programless Controller (With Stroke Study) How to Order

Programless Controller (With Stroke Study) How to Order Specialized for Series LEM Programless Controller (With Stroke Study) Series LECP RoHS P LE C P N Controller Compatible motor Step motor (Servo/ VDC) Number of step data (Points) stroke end points/ intermediate

More information

Ordering Information. Door Interlock Switch D2D. Power Switch with Minimum Contact Gap up to 3 mm. D2D - 0. Model Number Legend

Ordering Information. Door Interlock Switch D2D. Power Switch with Minimum Contact Gap up to 3 mm. D2D - 0. Model Number Legend Door Interlock Switch D2D Power Switch with Minimum Contact Gap up to 3 mm. Minimum contact gap of 3 mm (standard models), needed in general power switches, is provided. Mechanism with double return spring

More information

Add S to the end of the model number for the UL/CSA-approved version. Consult your OMRON sales representative for details.

Add S to the end of the model number for the UL/CSA-approved version. Consult your OMRON sales representative for details. Sealed Subminiature Snap ction Switch D2HW Smallest Sealed Snap-ction Switch in the Industry With a Long Stroke For Reliable ON/OFF ction Conforms to IP67 Case dimensions 22% smaller than conventional

More information

SI unit for EtherNet/IP TM EX250-SEN1

SI unit for EtherNet/IP TM EX250-SEN1 PRODUCT NAME SI unit for EtherNet/IP TM MODEL / Series / Product Number EX250-SEN1 Table of Contents Safety Instructions 2 Product Summary 7 Definition and terminology 8 Model Indication and How to Order

More information

Fieldbus system (SI unit compatible CompoNet)

Fieldbus system (SI unit compatible CompoNet) PRODUCT NAME Fieldbus system (SI unit compatible CompoNet) MODEL / Series / Product Number EX12#-SCM# Table of Contents Safety Instructions 2 Product Summary 7 Model Identification and How to Order 7 Names

More information

1. Safety Precautions (Read these precautions before use.)

1. Safety Precautions (Read these precautions before use.) R P5102S/N/N1 HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions

More information

Fieldbus system (DeviceNet compliant)

Fieldbus system (DeviceNet compliant) PRODUCT NAME Fieldbus system (DeviceNet compliant) MODEL / Series / Product Number EX510-GDN1 Series Table of Contents Safety Instructions 3 Model Indication and How to Order 8 Summary of Product Parts

More information

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC Standard (thin shape) Inductive Proximity Sensor Thin shape for space saving surface mounting Direct side wall mounting for bracket-less installation Ordering Information DC 3-wire Models Installation

More information

Varistor installation. Input logic. Voltage of relay coil

Varistor installation. Input logic. Voltage of relay coil Features For driving various loads using PLC output signals Easily check operation status and high luminance LED turns on with input signals Choose various relays depending on each load voltage or current

More information

RS232C/RS485 Data can be easily monitored by LAN

RS232C/RS485 Data can be easily monitored by LAN KS SIGNAL CVERTER (AKS) RSC/RS8 Data can be easily monitored by LAN KS SIGNAL CVERTER FEATURES The connectors are located on the front panel. Easy to connect Easy to operate Can be connected to the LAN

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual

Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual Thank you for purchasing FA Goods product. Before using, please read this User s

More information

SI unit for IO-Link device

SI unit for IO-Link device PRODUCT NAME SI unit for IO-Link device MODEL / Series / Product Number EX260-SIL1-X207 EX260-SIL1-X210 EX260-SIL3-X207 Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary

More information

: EX##-OMC0024-A. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1

: EX##-OMC0024-A. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1 : EX##-OMC00-A Instruction Manual SI Unit / DI Unit EX0-SDN EX0-IE SAFETY INSTRUCTIONS (Read carefully before use.) Thoroughly read this technical instruction manual and related manuals mentioned here

More information

Fieldbus system EtherCAT compatible SI unit

Fieldbus system EtherCAT compatible SI unit PRODUCT NAME Fieldbus system EtherCAT compatible SI unit MODEL / Series/ Product Number EX600-SEC# EX600-ED# Table of Contents Safety Instructions 2 System Outline 8 Definition and terminology 9 Assembly

More information

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Compact Magnetic Non-contact Safety Switches. Model Number Structure Compact Non-contact Safety Switches FS-TGR-N@C Coded Non-contact switches are designed to interlock hinge, sliding or removal guard doors. All coded Non-contact switches have a LED for easy diagnosis.

More information

Thread length (overall length)

Thread length (overall length) Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

PC RELAY TERMINAL/ PC TERMINAL

PC RELAY TERMINAL/ PC TERMINAL Input points Output points PC Relay (PC relays mounted) PC Input points Output points Input points Output points Input points Output points Input points Output points Output points ORDERING INFORMATION

More information

Classification Enclosure rating Input voltage Type of

Classification Enclosure rating Input voltage Type of Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.

More information

WARNING. To Prevent From Damage:

WARNING. To Prevent From Damage: WARNING When connecting a power cable to the GP unit, be sure the cable has been unplugged from the power outlet, so that you would not get an electric shock. High voltage runs in the GP unit, so if you

More information

FX1N-2EYT-BD Output Expansion Board

FX1N-2EYT-BD Output Expansion Board FX1N-2EYT-BD Output Expansion Board USER S MANUAL JY992D95201C This manual contains text, diagrams and explanations which will guide the reader in the correct installation, safe use and operation of the

More information

Optional add-on cassette Attachment Instruction manual

Optional add-on cassette Attachment Instruction manual E6580774 Optional add-on cassette Attachment Instruction manual 1. INTRODUCTION 3 2. CONNECTION TO THE INVERTER 4 2.1 Fixing the option alone 4 2.2 Connection to the inverter 6 3. SPECIFICATION 8 4. WARRANTY

More information

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings for Display of High-speed Addition and Subtraction Maximum operating speed 2kHz Used in industrial machinery, end-measuring devices, and the like, this electronic counter is exclusively for display. It

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

Digital Gap Checker. ON: Placed. Workpiece. Large gap. Workpiece. Workpiece. Small gap. Detection surface Detection nozzle. Air

Digital Gap Checker. ON: Placed. Workpiece. Large gap. Workpiece. Workpiece. Small gap. Detection surface Detection nozzle. Air -Color Display Digital Gap Checker. to.5 mm (Displayable/Settable range: to ) G type Rated detection distance range ON: Placed H type Rated detection distance range Workpiece.5 to. mm (Displayable/Settable

More information

Universal sensors and switches, universal output devices

Universal sensors and switches, universal output devices AnyWireASLINK System Products Guide ASLINKTERMINAL [ASLINK Small Terminal Block Terminal] BL29 B-0F -V50 EURO block type The Products Guide describes individual products. Refer to the Guide as necessary.

More information

SI unit for IO-Link device

SI unit for IO-Link device PRODUCT NAME SI unit for IO-Link device MODEL / Series / Product Number EX260-SIL1-X207 EX260-SIL1-X210 EX260-SIL3-X207 Table of Contents Safety Instructions 2 Model Numbers 8 Summary of Product 9 Summary

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

Analog Monitor Installation Manual

Analog Monitor Installation Manual Analog Monitor Installation Manual Part Number: 144-23919 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems and equipment.

More information

FX1N-4EX-BD Input Expansion Board

FX1N-4EX-BD Input Expansion Board Input Expansion Board USER S MANUAL JY992D95001C This manual contains text, diagrams and explanations which will guide the reader in the correct installation, safe use and operation of the FX 1N-4EX-BD

More information

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6 Cat.No I173E-EN-01 RX Inverter Expansion I/O Board 3G3AX-EIO21-ROE USER S MANUAL GENERAL PRECAUTIONS... 3 1 GENERAL DESCRIPTION... 6 2 INSTALLATION PROCEDURE... 7 2.1 INSTALLING THE EXPANSION I/O BOARD...

More information

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E Table of contents 1. INTRODUCTION...1 2. HARDWARE DESCRIPTION...2 3. INSTALLATION...6 4. CONNECTION...8 5. USER SAFETY AND PROTECTION OF THE EQUIPMENT...11

More information

DIN Rail Mounting Accessories. Style Appearance Use with Timers Part No. Appearance Part No. RTE-P2 SR3P Pin FingerSafe Socket RTE-P2 SR3P-05C

DIN Rail Mounting Accessories. Style Appearance Use with Timers Part No. Appearance Part No. RTE-P2 SR3P Pin FingerSafe Socket RTE-P2 SR3P-05C RTE Series DIN Rail Mounting Accessories Part Numbers: DIN Rail/Surface Mount Sockets and Hold-Down Springs DIN Rail Mount Socket Applicable Hold-Down Springs Style Appearance Use with Part No. Appearance

More information

Mitsubishi Electric Air-conditioner Network System

Mitsubishi Electric Air-conditioner Network System Mitsubishi Electric Air-conditioner Network System Central Controller Model: GB-50A Installation Manual Contents 1. Safety Precautions to be Observed without Fail...1 2. Confirmation of Parts...3 3. Product

More information

Switch Mode Power Supply

Switch Mode Power Supply Switch Mode Power Supply S8JX (/0/100/10-W Models) Compact Power Supply Compliant with Global Standards Output voltages of V, 12 V, and 2 V are available for between to 10 W capacity (100 W, 10 W: 2-V

More information

D4GS-N CSM_D4GS-N_DS_E_7_4

D4GS-N CSM_D4GS-N_DS_E_7_4 Slim Safety Door Switch D4GS-N CSM_D4GS-N_DS_E_7_4 Slim Safety Door Switches with IP67 Rating Slim design with a width of only 17 mm (three-contact models). Reversible design allowing either front or rear

More information

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated High-precision Optical Switch D5F CSM_D5F_DS_E_2_2 Optical System Achieves 1-μm Operating Position Repeatability in this 4-way Switch No-contact structure for high reliability. Ceramic materials in measuring

More information

Output Terminal Module

Output Terminal Module Output Terminal Module FA-TH16YRA11/11S/20/20S/20SL/21/21S,FA-TH16YRAC20S, FA-TH16YRAB20SL,FA-TH16YSR11S/20S/21S, FA-TH16YTL11S/21S,FA-TH16YTH11S,FA-TH16YTR20S, FA-TH16Y2TR20,FA-THE16YTH11S,FA-THE16YTR20S

More information

ERNT-AQTX10 ERNT-AQT68AD-GH. User s Manual. Mitsubishi General-Purpose Programmable Logic Controller Renewal Tool Conversion Adapter.

ERNT-AQTX10 ERNT-AQT68AD-GH. User s Manual. Mitsubishi General-Purpose Programmable Logic Controller Renewal Tool Conversion Adapter. Mitsubishi General-Purpose Programmable Logic Controller Renewal Tool Conversion Adapter Model ERNT-AQT68AD-GH User s Manual ERNT-AQTX10 Model ERNT-AQT68AD-GH 50CM-D180033-A(0810)MEE SAFETY PRECAUTIONS

More information

SiO Controller. SiO Controller. SiO-C Ver onwards SiO2/SiO2PNP Ver onwards SiO3 Ver onwards INSTRUCTION MANUAL. Version 3.

SiO Controller. SiO Controller. SiO-C Ver onwards SiO2/SiO2PNP Ver onwards SiO3 Ver onwards INSTRUCTION MANUAL. Version 3. SiO Controller SiO-C Ver. 2.00 onwards SiO2/SiO2PNP Ver. 1.00 onwards SiO3 Ver. 1.00 onwards INSTRUCTION MANUAL Version 3.2 WARRANTY RANGE Warranty Period 1 year period after date of purchase 1. This product

More information

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4 OPERATION MANUAL E/P REGULATOR MODEL NAME ITV*0*0 *0*0-DE**** series Series For DeviceNet TM CONTENTS TM Contents Safety Instructions P1 P2 Precautions for Handling P3-4 Wiring and LED display P5-6 Mounting

More information

DPDT Basic Switch for Two Independent Circuit Control

DPDT Basic Switch for Two Independent Circuit Control Special-purpose Basic Switch DZ CSM_DZ_DS_E DPDT Basic Switch for Two Independent Circuit Control Ideal for switching the circuits operating on two different voltages, and for controlling two independent

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

M8/M12 Connector. PCA/EX9/EX500 Series. Reduction in wiring time. Conforming to IEC Fieldwireable Connectors

M8/M12 Connector. PCA/EX9/EX500 Series. Reduction in wiring time. Conforming to IEC Fieldwireable Connectors / Connector /EX9/EX00 Series Fieldwireable Connectors Reduction in wiring time The man-hours can be decreased because no exclusive tools (such as solder, crimped terminal) are required.also, the wire length

More information

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor. Slot-type Photomicrosensor EE-SX CSM_EE-SX_DS_E Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. A built-in connector minimizes the shape and dimensional

More information

RUC-M industrial relays for DC loads

RUC-M industrial relays for DC loads Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Min. breaking capacity

More information

Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.

Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts. Peak G 15min Handheld Electrostatic Meter Series IZH10 How to Order IZH10 Option Nil H None High-voltage measuring handle Accessories and Option / Part Number for Individual Parts The ground wire and soft

More information

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Compact Magnetic Non-contact Safety Switches. Model Number Structure Compact Non-contact Safety Switches Coded Non-contact switches are designed to interlock hinge, sliding or removal guard doors. All coded Non-contact switches have a LED for easy diagnosis. Coded actuator

More information

Central Controller Model: G-50A

Central Controller Model: G-50A G-50A Mitsubishi Electric Air-conditioner Network System Central Controller Model: G-50A Installation Manual Contents / CENTRAL CTROLLER 1. Safety precautions to be observed without fail... 1 2. Confirmation

More information

1. Safety Precautions (Read these precautions before use.)

1. Safety Precautions (Read these precautions before use.) R P5043S/N HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions

More information

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT. This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT http://www.qualitrol.com/shop/p-14508-ic670gbi002.aspx Provides the wiring diagrams and installation guidelines for this GE Field Control module.

More information

Low Price Rectangular-shaped Inductive Proximity Sensor. The GL-N12 series is recommended to large volume users for cost reduction.

Low Price Rectangular-shaped Inductive Proximity Sensor. The GL-N12 series is recommended to large volume users for cost reduction. SERIES ow Price Rectangular-shaped Inductive Proximity PNP output Different freq. type available type available mplifier Built-in Wide variety with total cost reduction! G-10/GH GX GX-N GX-U/FU G-18H/18H

More information

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors Standard-type Connector- Conversion Units XWB CSM_XWB_DS_E Simplifies Connector and terminal block replacement, and requires less in-panel wiring. Mount to DIN Track or via screws. MIL Flat Cable Connectors

More information

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety Compact for High-Density Mounting with Easy Snap-In Connector H Connector features a built-in safety lock for shock and vibration resistance H replacement made simple without rewiring H Cables can be bent

More information

The importance of the static electric control is put on confirming the actual status.

The importance of the static electric control is put on confirming the actual status. Electrostatic Sensor IZD10/IZE11 Series Potential measurement: ±20 kv (detected at a 50 mm distance) ±0.4 kv (detected at a 25 mm distance) Detects the electrostatic potential and outputs in an analog

More information

Instruction Manual for Electric Vehicle (EV) Quick Charging Connector

Instruction Manual for Electric Vehicle (EV) Quick Charging Connector Manual No.20022469111 Dated June. 14,2017 Instruction Manual for Electric Vehicle (EV) Quick Charging Connector Information in this instruction manual is subject to change without prior notice. Power Cable

More information

Flow Monitor PF2A20# PF2W20# PF2D20#

Flow Monitor PF2A20# PF2W20# PF2D20# PRODUCT NAME Flow Monitor MODEL / Series / Product Number PF2A20# PF2W20# PF2D20# Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 12 Definition and

More information

Fieldbus system EtherNet/IP TM compatible SI Unit

Fieldbus system EtherNet/IP TM compatible SI Unit PRODUCT NAME Fieldbus system EtherNet/IP TM compatible SI Unit MODEL / Series / Product Number EX600-SEN3/4 EX600-ED# Table of Contents Safety Instructions 2 System Outline 8 Definition and terminology

More information

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs 19 Ultra-small Micro Photoelectric Sensor PM- SERIES Related Information General terms and conditions...p.1 Glossary of terms / General precautions...p.98~ / P.98~ Amplifier Built-in Sensor selection guide...p.11~

More information

Round Water-resistant Connectors (M8) XS3

Round Water-resistant Connectors (M8) XS3 Round Water-resistant Connectors () XS Compact, Watertight, Round Connectors Water-resistive, compact connector meets IP67 requirements. Ideal for a wide variety of FA and OA applications. Using connectors

More information