M8/M12 Connector. PCA/EX9/EX500 Series. Reduction in wiring time. Conforming to IEC Fieldwireable Connectors
|
|
- Shauna Richards
- 6 years ago
- Views:
Transcription
1 / Connector /EX9/EX00 Series Fieldwireable Connectors Reduction in wiring time The man-hours can be decreased because no exclusive tools (such as solder, crimped terminal) are required.also, the wire length can be adjusted at the site. QUICKON-ONE Spring-cage Connection Piercecon Conforming to IEC Reduction in wiring time Just insert the connector and make / rotation. Knurl Align here. EX0 EX80 EX60 EX0 EX00 EX0 Make / rotation. IP67 (IEC609) Conforming to IEC The coloring and number indication to the electrical connection makes less wrong wiring. Blue Black Blue Black 907
2 It provides the Fieldbus communication unit and input device applicable to Communication Cable/Connector P. 9 to P. 9 It has a product lineup applicable to any communication standards. The SMC Fieldbus (SI) Unit can be connected to the PLC (controller) and communication units of other manufacturers with cables with connectors and fieldwireable connectors (with shield) applicable to the standards of CC-Link, DeviceNet TM, and PROFIBUS DP. PLC Manifold solenoid valve P.9 P.9 P.9 Communication cable Fieldwireable communication connector Terminal plug (Terminating resistor) It is connected to the communication port of the communication unit connected at the end. Socket (Female) For CC-Link For DeviceNet TM 0 For PROFIBUS DP Plug (Male) For CC-Link 7 For DeviceNet TM For PROFIBUS DP 9 Plug (Male) For CC-Link 6 For DeviceNet TM For PROFIBUS DP Socket (Female) For CC-Link 8 For DeviceNet TM For PROFIBUS DP For DeviceNet TM (Plug) For PROFIBUS DP (Plug/B-coded) Product Table Description Application No. SMC part no. Name Cable with connector Fieldwireable connector Terminal plug For Fieldbus communication For Fieldbus communication For Fieldbus communication Communication cable for CC-Link (Socket) Communication cable for CC-Link (Plug) Communication cable for DeviceNet TM (Socket) Communication cable for DeviceNet TM (Plug) Communication cable for PROFIBUS DP (Socket/B-coded) Communication cable for PROFIBUS DP (Plug/B-coded) Fieldwireable connector for CC-Link (Plug/Spring-caged) Fieldwireable connector for CC-Link (Socket/Spring-caged) Fieldwireable connector for DeviceNet TM (Plug/Spring-caged) Fieldwireable connector for DeviceNet TM (Socket/Spring-caged) Fieldwireable connector for PROFIBUS DP (Plug/B-coded/Spring-caged) Fieldwireable connector for PROFIBUS DP (Socket/B-coded/Spring-caged) Terminating resistor for DeviceNet TM () Terminating resistor for PROFIBUS DP (/B-coded) 908
3 / connector and the sensor/switch connected to them as a total system. Between Sensor/Switch and Input Device P. 96 to P. 99 Connection between connectors and products Pressure switch Fieldwireable connector P.97 Cable with connector P.98 Input block It has a product lineup of the fieldwireable connector that does not need any special tools. The lead wires can easily be made into / connector by changing the wire length. Piercecon connection The wiring can be changed accordingly. 9 Input unit manifold EX00 series Select the input block of the EX00 series according to the sensor output specification. 6 8 EX0 Auto switch QUICKON-ONE connection Y connector P.99 The input block reads sensor signals with one port. The wires of the auto switch and the pressure switch that has one output type can be decreased by unifying the signal wires using a Y connector. x EX00-IE, EX00-IE, EX00-IE, 6 Manifold solenoid valve with input/ output unit EX0 series EX0-IE, EX80 EX60 EX0 EX00 EX0 / connector (Fieldwireable/Pre-wired) x 8 EX0-IE Pre-wired type -input type input block is the -type connector only. Product Table Description Cable with connector Fieldwireable connector Y connector For sensor For sensor For sensor Application No. SMC part no. Name Cable with connector ( pins/ m) Cable with connector ( pins/ m) Fieldwireable connector (/ pins/plug/piercecon connection) Fieldwireable connector (/ pins/plug/quickon-one connection/) Y connector ( x ( pins)- ( pins)/) Y connector ( x ( pins)- ( pins)/) 909
4 Other / Connector Accessories (EX00/EX0/EX9) B Power cable with connector (For GW unit) A Communication connector F Seal cap (For socket) C Cable with connector Output block Power block P. 90 to P. 9 B Power cable with connector (For EX0/Power block) E Cable with connector for output entry F Seal cap (For socket) D Terminal plug F Seal cap (For plug) A Communication connector B Power cable with connector D Terminal plug (For EX00) For DeviceNet TM (With cable) For GW unit (A-coded) For EtherNet/IP TM or EtherCAT For EX0/Power block (B-coded) E Cable with connector for output entry (RJ-, with cable) C Cable with connector (For EX00) F Seal cap For plug For socket Other / Connector Accessories (EX00/EX0/EX9) Description Cable with connector 90 Terminal plug Seal cap Application No. SMC part no. Name EX00-AC -DN Communication cable for DeviceNet TM (Socket) For Fieldbus A communication Communication cable for EtherNet/IP TM or EtherCAT EX9-AC00EN-PSRJ ( plug/d-coded-rj) EX9-AC - EX00-AP -S For power supply B EX00-AP -A Power cable with connector (Socket/A-coded) Power cable with connector (Socket/B-coded) For EX00 C EX00-AC -SSPS Cable with connector (8 pins/both straight) EX00-AC -SAPA Cable with connector (8 pins/both angle) For output entry For EX00 For plug E D F EX9-AC -7 EX00-AC000-S EX00-AWTP EX9-AWES EX9-AWTS Cable with connector (Plug/A-coded) Terminal plug (/8 pins) Seal cap (/For plug) Seal cap (/For socket) Seal cap (/For socket)
5 Communication Cable/Connector Example of Connection/Specifications CC-Link DeviceNet TM PROFIBUS DP Dimensions Between Sensor/Switch and Input Device Example of Connection Specifications/Dimensions Fieldwireable connector Cable with connector Y connector Other Accessories Example of Connection How to Order/Dimensions Compatibility between Sensors and Fieldwireable Connectors American Wire Gauge Conversion Table Safety Instructions/Precautions P.9 P.9 P.9 P.9 P.96 P.97 P.98 P.99 P.90 P.9 P.9 P.96 P.97 EX0 EX80 EX60 EX0 EX00 EX0 9
6 Communication Cable/Connector Example of Connection PLC Serial wiring with Input/Output unit Solenoid valve manifold IN side IN side OUT side EX0 Series OUT side Specifications Series Part no. Description Communication cable (With one side connector) Fieldwireable connector Product image Number of functional poles Key type Pin assignment Note) Rating/Performance Material Fixed cable length Cable O.D. Wire gauge (Stranded wire cross section) Wire outer diameter (Including insulating material) Connection type Rated current Rated voltage Contact resistance Insulation resistance Withstand voltage Ambient Connector temperature Operating Cable Fixed Weight Protection class Allowable repeated insertion/withdrawal Cable retaining force Material of knurl Contact (Surface treatment) Insulating material Material of sheath Socket Approx. 06 g Plug Plug Socket : poles Plug, A-coded Socket, A-coded (Viewed from the plug/socket side) Approx. 08 g Approx. 8 g : SLD (Shield wire) : DB () : DG (Yellow) : DA (Blue) Approx. g Note) The shaded parts show the specifications for the applicable cable. Adaptation for the connector may vary on account of the conductor construction of the electric wire. 9 m 7.7 ±0. mm 0. mm /AWG0. ±0.07 mm 0 V to 90 C 0 to 60 C 0 to 60 C 0 N/ sec. Zinc die-cast A mω 00 MΩ. kv IP67 (Only with screw tightened) 00 Applicable cable CuSn (Au plating (Ni plating)) Thermoplastic polyurethane (TPU) Polyvinyl chloride ().0 to 8.0 mm 0. to 0. mm /AWG6 to 0 Spring-cage connection 8 V 0 to 8 C Brass Polyamide (PA6.6)
7 Communication Cable/Connector Example of Connection PLC Serial wiring with Input/Output unit Solenoid valve manifold Connected at the end Discrete and decentralized serial wiring GW unit EX0 Series Specifications Part no. Product image Description Number of functional poles Key type Pin assignment Note) Rating/Performance Material Fixed cable length Cable O.D. Wire gauge Power pair (Stranded wire cross section) Data pair Wire outer diameter Power pair (Including insulating material) Data pair Connection type Rated current Rated voltage Contact resistance Insulation resistance Withstand voltage Ambient Connector temperature Operating Cable Fixed Protection class Allowable repeated insertion/withdrawal Cable retaining force Material of knurl Contact (Surface treatment) Insulating material Material of sheath EX00 Series Communication cable (With one side connector) Fieldwireable connector Terminal plug Socket Plug Plug Socket : poles DeviceNet TM / CANopen : DRAIN : : V+ (Red) : Plug, A-coded Socket, A-coded : V (Black) : CAN GND : CAN H () : CAN H (Viewed from the plug/socket side) : CAN L (Blue) : CAN L m 6.70 ±0. mm.0 to 8.0 mm Applicable 0. mm /AWG cable 0. to 0. mm /AWG6 to 0 0. mm /AWG. ±0.0 mm.0 ±0.0 mm Spring-cage connection A 8 V mω 00 MΩ.0 kv to 90 C 0 to 8 C 0 to 7 C 0 to 80 C IP67 (Only with screw tightened) 00 0 N/ sec. Zinc die-cast Brass CuSn (Au plating (Ni plating)) Thermoplastic polyurethane (TPU) Polyamide (PA6.6) Polyurethane (PUR) For DeviceNet TM (Plug, A-coded) : DRAIN: NC : V+: NC : V : NC : CAN H Ω : CAN L Weight Approx. 08 g Approx. 06 g Approx. 7 g Approx. g Approx. g Note) The shaded parts show the specifications for the applicable cable. Adaptation for the connector may vary on account of the conductor construction of the electric wire. to 90 C Zinc die-cast Thermoplastic polyurethane (TPU) 9 EX0 EX80 EX60 EX0 EX00 EX0
8 Communication Cable/Connector Example of Connection PLC A product connected at the end Serial wiring with Input/Output unit Solenoid valve manifold 0 IN side 0 OUT side Discrete and decentralized serial wiring GW unit EX0 Series Specifications EX00 Series Part no. Description Communication cable (With one side connector) Fieldwireable connector Terminal plug Product image Number of functional poles Key type Socket Plug Plug Socket : poles : poles B-coded (Reverse key) For PROFIBUS DP (Plug, B-coded) : poles : : VP : A Line (Green) : B Line 90Ω Pin assignment : Plug, B-coded Plug, B-coded : B Line (Red) : A Line : : DGND (Viewed from the plug/socket side) 0Ω 90Ω Fixed cable length m Cable O.D ±0. mm Applicable.0 to 8.0 mm Wire gauge (Stranded wire cross section) 0. mm /AWG cable 0. to 0. mm /AWG6 to 0 Wire outer diameter (Including insulating material). ±0.07 mm Connection type Spring-cage connection Rated current A Rated voltage 60 V 8 V 60 V Contact resistance mω Insulation resistance 00 MΩ Withstand voltage. kv Ambient Connector to 90 C 0 to 8 C to 90 C temperature Operating 0 to 80 C Cable Fixed 0 to 8 C Protection class IP67 (Only with screw tightened) Allowable repeated insertion/withdrawal 00 Cable retaining force 0 N/ sec. Material of knurl Zinc die-cast Brass Zinc die-cast Contact (Surface treatment) CuSn (Au plating (Ni plating)) Insulating material Polyamide (PA6.6) Thermoplastic polyurethane (TPU) Material of sheath Polyurethane (PUR) Weight Approx. g Approx. 6 g Approx. 8 g Approx. g Approx. g Note) The shaded parts show the specifications for the applicable cable. Adaptation for the connector may vary on account of the conductor construction of the electric wire. Note) Rating/Performance Material 9
9 Communication Cable/Connector Dimensions Communication cable (With one side connector) For CC-Link (Socket) ø.8. ø Terminal no. Terminal no. Cable wire colors For CC-Link : DB (Plug) : SLD Yellow: DG Blue: DA Cable wire colors : DRAIN Red: V+ Black: V : CAN H Blue: CAN L Terminal Cable wire no. colors : Green: A Line : Red: B Line : Shield line is connected to the knurl. Fieldwireable connector 6-76 For DeviceNet TM (Socket) -766 For DeviceNet TM (Plug) For PROFIBUS DP (Socket) B-coded (Reverse key) -769 For PROFIBUS DP (Plug) B-coded (Reverse key) ø.8 ø.8 ø.8 ø.8 ø Plug Socket For CC-Link For DeviceNet TM For PROFIBUS DP For CC-Link For DeviceNet TM For PROFIBUS DP 60 8 ø7.7 ø6.7 ø6.7 ø7.8 ø EX0 EX80 EX60 EX0 EX00 EX0 ø9 ø7 ø9 ø7 A-coded (Normal key) B-coded (Reverse key) Width across flats 6 A-coded (Normal key) B-coded (Reverse key) Width across flats 6 Terminal plug Terminating resistor for DeviceNet TM ø Terminating resistor for PROFIBUS DP ø
10 Between Sensor/Switch and Input Device Example of Connection Sensor with pre-wired connector Direct connection between connectors Cable with connector P.98 Input block Input unit manifold EX00 series 8 Sensor with lead wire entry Lead wire / connector conversion Fieldwireable connector 6 P.97 8 EX00-IE, EX00-IE, EX00-IE, 6 QUICKON-ONE connection 7 connection 9 Manifold solenoid valve with input unit EX0 series Auto switch with pre-wired connector Y connector x 0 P.99 EX0-IE, EX0-IE 8 Pre-wired type Can be wired to the input block after converting -output signal to -output signal. ( only) / connector (Fieldwireable/Pre-wired) Auto switch with lead wire entry Lead wire / connector conversion x Fieldwireable connector P.97 6 QUICKON-ONE connection 7 connection 96 Cut the cable into the necessary length, and wire with fieldwireable connectors.
11 Between Sensor/Switch and Input Device Fieldwireable Connector Specifications Part no. Product image/pin assignment Number of functional poles Key type Cable O.D. Wire gauge (Stranded wire cross section) Core wire diameter (Including insulating material) Note) Rating/Performance Material Applicable cable Connection type Rated current Rated voltage Contact resistance Insulation resistance Withstand voltage Ambient temperature Protection class Allowable repeated insertion/withdrawal Allowable number of repeated connection between conductors of the same cross section Material of knurl Contact (Surface treatment) Insulating material Weight Plug Plug Plug Note) The shaded parts show the specifications for the applicable cable. Adaptation for the connector may vary on account of the conductor construction of the electric wire. Dimensions : poles.0 to.0 mm 0. to 0. mm /AWG6 to 0. to 0. mm /AWG to.0 to.6 mm Piercecon connection 60 V.0 kv 0 to 8 C 00 Brass Approx. g. to 6.0 mm 0. to 0. mm /AWG6 to 0.7 to. mm A mω 00 MΩ : poles QUICKON-ONE connection 0 V. kv to 80 C IP67 (Only with screw tightened) 0 00 Zinc die-cast CuZn (Au plating (Ni plating)) Polyamide (PA6.6) Approx. g.0 to 8.0 mm 0. to 0.7 mm /AWG to 8. to. mm Approx. g EX0 EX80 EX60 EX0 EX00 EX0-770 Fieldwireable connector (). Wire color ø Fieldwireable connector () Width across flats Width across flats ø6. Blue Black Wire color Blue Black Fieldwireable connector () Width across flats ø.8 SW ø8. Wire color Blue Black 97
12 Between Sensor/Switch and Input Device Cable with Connector Specifications Part no Product image Number of functional poles Key type Rating/Performance Material Fixed cable length Cable O.D. Wire gauge (Stranded wire cross section) Rated current Rated voltage Contact resistance Insulation resistance Withstand voltage Ambient Connector temperature Operating Cable Fixed Weight Protection class Allowable repeated insertion/withdrawal Cable retaining force Material of knurl Contact (Surface treatment) Insulating material Material of sheath : poles m.7 ±0. mm 0. mm /AWG A 0 V mω 00 MΩ. kv to 90 C to 80 C 0 to 80 C IP67 (Only with screw tightened) 00 0 N/ sec. Zinc die-cast CuSn (Au plating (Ni plating)) Thermoplastic polyurethane (TPU) Polyurethane Black (PUR Black) Approx. g : poles. ±0. mm 0. mm /AWG 60 V.0 kv 0 N/ sec. Approx. 80 g Dimensions Cable with connector ( poles) ø ø.7 ø Cable with connector ( poles) ø0 ø. ø0 98
13 Between Sensor/Switch and Input Device Y Connector Specifications Part no Product image 0 Number of functional poles Key type Rating/Performance Material Rated current Rated voltage Contact resistance Insulation resistance Withstand voltage Ambient temperature Protection class Allowable repeated insertion/withdrawal Material of knurl Contact (Surface treatment) Insulating material Weight Dimensions Y connector ( x -) ø Y connector ( x -). 8 ø ø..8 x : poles : poles x : poles : poles A 60 V mω 00 MΩ.0 kv to 90 C IP67 (Only with screw tightened) 00 Zinc die-cast CuZn (Au plating (Ni plating)) Thermoplastic polyurethane (TPU) Approx. 9 g Approx. g.8 ø ø ø.8.6 ø.8.7 q w q w EX0 EX80 EX60 EX0 EX00 EX0 99
14 Other Accessories / Connector Accessories (EX00/EX0/EX9) A B Power cable with connector (For GW unit) F Communication connector Seal cap (For socket) C Cable with connector Output block Power block B Power cable with connector (For EX0/Power block) E Cable with connector for output entry F Seal cap (For socket) AS-Interface F Seal cap (For plug) D Terminal plug G Power cable with connector H Power cable with connector (for SI unit) A B C Communication connector For DeviceNet TM (with cable) For EtherNet/IP TM or EtherCAT (RJ-, with cable) Power cable with connector For GW unit (A-coded) For EX0/Power block (B-coded) Cable with connector (For EX00) D Terminal plug (For EX00) E F Cable with connector for output entry Seal cap For plug For socket G Power cable with connector H Power cable (for SI unit) 90
15 Other Accessories A Communication connector For DeviceNet TM 00 EX00 AC Cable length (L) [mm] [mm] ø ø7 L DN For EtherCAT or PROFINET SI unit EX9 AC 00 EN Cable length (L) [mm] [mm] [mm] [mm] [mm] D-coded ø6.7 PSRJ Connector specification plug (Straight) PSRJ RJ- connector 7. L B Power cable with connector (For GW unit, SI unit (A-coded)) EX00 AP 00 S 0 Core wire colors : DRAIN Red: V+ Black: V : CAN H Blue: CAN L Core wire colors (Straight cable) Orange Green Shield Paired Paired RJ- EX0 EX80 EX60 EX0 EX00 EX0 Cable length (L) [mm] [mm] Connector specification S Straight A Angle Straight connector type Angle connector type ø6 ø L ø6 0 Core wire colors Blue Black Gray L 0 Core wire colors Blue Black Gray 9
16 Other Accessories / Connector Accessories (EX00/EX0/EX9) B Power cable with connector (For EX0/Power block (B-coded)) L EX9 AC Cable length (L) [mm] [mm] [mm] Core wire colors Blue Black Gray ø C Cable with connector EX00 AC 00 SSPS Cable length (L) [mm] [mm] [mm] [mm] [mm] Connector specification SSPS Socket side: Straight, Plug side: Straight SAPA Socket side: Angle, Plug side: Angle Straight connector type Angle connector type L 8 ø6 ø.9 Core wire colors Green 7 Yellow Gray Pink Blue 8 8 Shield ø ø6.. L Core wire colors Green Yellow Gray 6 Pink 7 Blue 8 Shield D Terminal plug This is used where an input unit manifold (input unit/input block) is not being used. (If a terminal plug is not used, the GW unit s COM LED will not light up.) EX00 AC000 S ø6.7 9
17 Other Accessories E Cable with connector for output entry EX9 AC 00 7 L Cable length (L) [mm] [mm] Core wire colors Blue Black Gray ø F Seal cap: connector (For plug) Use this on ports that are not being used for a connector (plug). Use of this waterproof cap maintains the integrity of the enclosure. Note) Tighten the waterproof cap with the prescribed tightening torque. (For : 0. N m) EX00 AWTP ø.9 9. F Seal cap:, connector (For socket)/accessories Use this on ports that are not being used for a, connector (socket). Use of this waterproof cap maintains the integrity of the enclosure. (Waterproof cap is packed together with each unit.) Note) Tighten the waterproof cap with the prescribed tightening torque. (For : 0.0 N m, For : 0. N m) EX9 AW Connector type ES connector (For socket, 0 pcs.) TS connector (For socket, 0 pcs.) EX0 EX80 EX60 EX0 EX00 EX x 0. x connector (For socket) connector (For socket) 9
18 Other Accessories / Connector Accessories (EX00/EX0/EX9) G Power cable with connector Connects between the power supply connector for the power block and the SI unit power supply connector, bridging the external power supply, which is supplied with the power block, to the SI unit. EX9 AC00 EX9-AC00- SI unit type EX0-SDN EX0-SMJ Compliant EX0-SCAA EX0-SPR Compliant EX0-SEN EX0-SAS/ Compliant EX9-AC00- Reverse keyway 00 Blue Black Gray Connections 00 ø6. ø6. 8. Reverse keyway 8. Reverse keyway Blue Black Gray Connections EX9-AC00-00 ø6. 8. Reverse keyway Connections H Cable connecting between AS-Interface power supply line (for external devices) branch connector () and the power block s power supply input connector. EX9 AC 00 9 AS-Interface power cable Cable length (L) [mm] [mm] [mm] 8. Reverse keyway L Connections ø6.
19 Compatibility between Sensors and Fieldwireable Connectors Pressure Switch Model Cable part no. Number of cores : Applicable : Applicable, but number of electric wire cores is limited. (Number of sensor lead wire cores is larger than the number of connector pins.) : Connectable, but may not correspond to IP6/67 depending on installation method. Applicable connector Cable specifications Sheath Insulator Conductor 6 7 O.D. Material O.D. Material Nominal cross section O.D. Strand diameter : Non-conformance Note Z/ISE0A- ZS-8- ZS-8- ø. ø mm (AWG6) ø mm ISE- Z/ISE0A - ISE70/7(H)- Z/ISE80 - ISA- Flow Switch Model PFA7 PFW7 ZS--A- Integrated type ZS--B ZS--C Integrated type ISA-8-A ISA-8-B Cable part no. ZS-7-A ZS-7-B Number of cores ø. ø. ø.0 ø. ø6.0 ø.0 ø. ø0.9 ø. ø0.9 ø.7 ø. 0.0 mm (AWG) 0. mm (AWG6) 0.0 mm (AWG) 0. mm (AWG6) 0. mm (AWG) AWG ø0.8 ø0. ø0.7 ø0. ø0.9 ø mm 0.08 mm 0.08 mm 0.08 mm 0.8 mm Applicable connector Cable specifications Sheath Insulator Conductor 6 7 O.D. Material O.D. Material Nominal cross section O.D. Strand diameter 0.08 mm Straight Angle Straight Angle Note Straight Angle EX0 EX80 EX60 EX0 EX00 EX0 PFM7 ZS--D ø. ø.00 AWG6 ø mm Note) Information on cable specifications is based on specification sheets supplied by the manufacturer. 9 A
20 American Wire Gauge Conversion Table This table shows to change American wire gauge (AWG) into a diameter. The wire material is indicated as AWG (American wire gauge) in the documentations overseas. Use the following table for conversion into diameter. Wire size (AWG) Diameter (mm) 7.8 Cross section (mm ).86 Wire size (AWG) 7 Diameter (mm). Cross section (mm ).000 Wire size (AWG) Diameter (mm) 0.8 Cross section (mm )
21 Cable/Connector Accessories Precautions Be sure to read this before handling the products. Caution. Do not lay the wires while they are energized. It may give you an electric shock.. It should be cabled according to the connection diagram.. Check if it can be connected when using a sensor or switch.. When the cable sheath is stripped, confirm the stripping direction. (For SMC switches with oblong cables) The insulator may be split or damaged depending on the direction. Tightening of Screw Caution. It cannot maintain the enclosure (IP6 ) or the screws may be loosened if they are not tightened sufficiently.. Check that they are tightened enough at appropriate intervals during the operation. Connection and Disconnection of Connector Caution. Be sure to turn the power off when connecting and disconnecting the connectors.. Do not touch surface of the engagement with wet hands.. Do not pull the cable out by holding the cable.. Note the key direction. Especially for the specifications, match the protrusion of the knurl (bracket) and the mark at the mold for insertion so that the function can be maintained.. When engaging the connectors, insert the connectors enough until all the engagement surfaces can be hidden and tighten the screws not to damage the thread ridges. Handling of Cable with Connector Caution. Avoid repeatedly bending or stretching the cable and applying a heavy object or force to it.. Set up the cables to the place where they cannot be stepped on in order to prevent them being broken or damage to the connectors. Install a protective cover in case it is used in the place stated above.. Do not pull the connector or cable unnecessarily. It may damage the connectors or break the cables.. Do not bend the cable at the root of the connector when installed. Handling of Fieldwireable Connector Caution Common Precautions. Follow Assembly Procedure provided by SMC. If not, it may not maintain IP6/67.. Do not use it besides an original purpose.. This connector may only be operated when under no load.. The work by the wet hand causes the electric shock.. Never perform the repair. Spring-cage Connection. Do not use it besides an original purpose. EX0. This connector may only be operated when under no load. EX80. The work by the wet hand causes the electric shock.. Never perform the repair. EX60 QUICKON-ONE Connection EX0. Connection between cables (with the same material and the same cross section) is 0 times at max.. or PE is suitable for sheath material, however fluoro resin is not suitable for sheath material. EX00. Only for flexible cable, not for solid cable. EX0. When you remove the cable, pull the cable. However, if you remove the Cable gland, cable and the Splice ring remain to the body. When you connect the cable again, screw the Splice ring approx. two turns into the Cable gland before using.. When you connect the cable again, cut and strip the cable. Piercecon Connection. Connection between cables (with the same material and the same cross section) is 0 times at max.. Only for flexible cable, not for solid cable.. If you connect the cable again, cut and strip the cable. Operating Environment Caution. Do not use in the atmosphere and environment over the rated specifications.. Do not use in the environment of corrosive gas or liquid splash.. Do not use in an environment where oil and chemicals are used. Maintenance Caution. Perform periodic inspection. 97
Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm
Fieldbus System (Output device for driving port solenoid valves) Compact 8mm (Actual size) Space-saving Installation Daisy-chain wiring communication New IP67 For units with D-sub connector, and when connected
More informationInformation. EX260 Integrated Type (For Output) Serial Transmission System 5 Port Solenoid Valve mm. Series SY/SV/VQC/S0700
Information Akihabara UX F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN URL http://www.smcworld.com 00 SMC Corporation All Rights Reserved 09-E6 -N Printing OT 0KS EX60 Integrated Type (For Output) Serial
More information11 PROFIBUS Fieldbus Connector
750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm 5 < 36,7mm < 372 mm < 54 mm < 36 mm / 42 in < 5-6 mm / 022 in < 0 mm / 0394 in The fieldbus connector links a PROFIBUS device
More informationSeries EX600. Fieldbus System EX600 S DN. SI Unit. How to Order. Specifications. SI Unit. SI Unit COM. 1 PNP ( COM.) 2 NPN (+COM.)
Fieldbus System Series EX600 SI Unit How to Order EX600 S DN SI Unit Fieldbus protocol DN DeviceNet TM MJ CC-Link PR PROFIBUS DP SI Unit COM. PNP ( COM.) NPN (+COM.) EX600-SDN EX600-SMJ EX600-SPR Specifications
More informationPROFIBUS Fieldbus Connector 634
750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm < 36,7mm < 372 mm < 54 mm < 36 mm / 142 in < 5-6 mm / 022 in < 10 mm / 0394 in The fieldbus connector links a PROFIBUS
More informationContents. EX600 serial interface unit (PROFIBUS DP, DeviceNet, EtherNet/IP, EtherCAT)
19 Fieldbus 160 Fieldbus Contents EX600 serial interface unit (PROFIBUS DP, DeviceNet, EtherNet/IP, EtherCAT) EX260 serial interface unit (DeviceNet, PROFIBUS DP, PROFINET, EtherCAT) EX20 serial interface
More informationBetter all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.
Better all-round. X coded D coded 10 GBE PoE+ DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications STX M12x1 IP67 connector series With the STX M12x1 IP67 connector
More informationD-Sub SEaled subminiature D connectors, 2.54 mm pitch
SE D-Sub SEaled subminiature D connectors, 2.54 mm pitch Page Technical characteristics.......................................... 02 IP 67 versions with turned solder cups......... 04 IP 67 versions with
More informationIndustrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications
Industrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications Type 0981 ENC 100 RJ45/M12 adaptor, female receptacle connector M12, D coding, chassis side thread PG 9, RJ45 female connector,
More informationAccessories Fieldbus Box
Power cables, sensor cables, connection cables and further accessories see the EtherCAT Box chapter from page 514 Pre-assembled cables for fieldbus components include a wide range of cable assemblies.
More informationBCC Part Number Matrix Breakdown Balluff cables, cordsets & connectors for industial automation equipment
BCC Part Number Matrix Breakdown Balluff cables, cordsets & connectors for industial automation equipment M8 Nano, M12 Micro - Single & Double-Ended Cables BCC M415 - M424-3A - 304 - VX44T2-020 - C008
More informationOperation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit
Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536
More informationODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic
ODU MINI-SNAP PC Product Description ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic Cylindrical Connectors are generally available with several locking mechanisms: The most frequently
More informationØ 11,4 21,5. M9 x 0,5 Ø 12 Ø 11,4. M9 x 0,5 Ø 12. M9 x 0,5
Subminiature 7 series Screw termination M9 8 contacts Degree of protection IP7 Solder termination Moulded versions Diameter, mm Male angled connector 8,, Ø,, Contacts Cable outlet Ordering-No. 99 00 70
More informationElectrical adapters, Sub-D socket, 9-pin Technical data
Electrical adapters, Sub-D socket, 9-pin Fieldbus adapter FBA Fieldbus adapter Sub-D, 9-pin on M12 or screw terminal, for CANopen and DeviceNet General technical data Electrical connection 1 Straight socket,
More informationWINSTA. Full Line Catalog 2008/2009
WINSTA Full Line Catalog 2008/2009 5 Contents FULL LINE CATALOG W4, Volume 1 Rail-Mounted Terminal Block Systems FULL LINE CATALOG W4 Rail-Mounted Terminal Blocks Volume 1 X-COM -SYSTEM Terminal Strips
More informationBreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide
This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check
More informationM12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET
M12 Connectors Application Advantage Shielded design ETHERLINE Ethernet Cable, Connectors & Tools M12 Field Wireable Connectors Male Female Temperature Range: Max. 85 C Nominal Voltage: Nominal Current:
More informationSAC-5P-MS/ 1,0-920/FS SCO
Extract from the online catalog SAC-5P-MS/ 1,0-920/FS SCO Order No.: 1518274 Bus system cable, DeviceNet/CANOpen, 5 pos., PUR halogen-free violet, shielded, straight M12 SPEEDCON connector on straight
More informationOperating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High
Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and contacts available High performance insulation material General characteristics and technical
More informationM12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector
M12 connectors Directory Chapter Page General information....02 M12 connector D-coding....06 M12 connector X-coding....20 RJ45 IP20 connector....27 PushPull RJ45 IP65 / IP67 connector....46 Han 3 A RJ45
More informationSUBCON-PLUS-PROFIB...
Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12
More informationEX120/121/122 Series Some protocols are not CE-compliant.
Output type for solenoid valves (For Output) EX120/121/122 Series Compatible Protocols CompoBus/S NKE Corp.: Fieldbus H System Made to Order Small unit compatible with a maximum of 16 outputs Compatible
More informationEPIC Circular Connectors CIRCON M23 Series
The M3 connectors have many inherent features which offer application advantages and provide significant benefits for the customer. These features make it one of the most application friendly connectors
More information400 Series Buccaneer BUCCANEER FOR POWER. IP68 rating tested at 1.054kg/sq cm (15lb/sq in) 10m depth for 2 weeks
IP68 rating tested at 1.054kg/sq cm (15lb/sq in) m depth for 2 weeks IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k 2 and 3 pole -, 250V rating 4, 6 and 8 pole -, 125V rating and 12 pole -, 50V
More informationSlim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations
Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay
More informationOption 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter
Series 0-PSE00 RoHS Remote Type Multi-Channel Digital Pressure Sensor Controller How to Order Clean series 0 PSE0 0 M Input/Output specifications 0 NPN 5 outputs + Auto shift input PNP 5 outputs + Auto
More informationBVS UR E Ordering code: BVS001H
BVS UR-3-101-E Ordering code: BVS001H Vision sensor BVS-E Universal PNP (2x) 1) Teach reference image, 2) Power, 3) Output 1 active, 4) Output 2 active, 5) Connection with PC, 6) Sharpness Characteristic
More informationField bus connections Link structure BDC Link structure BDC, B-design. Brochure
Field bus connections, B-design Brochure Field bus connections, B-design Bus coupler with driver Direct field bus connection (BDC) Bus coupler with driver direct field bus connection Field bus protocol:
More informationYour Benefits at a Glance
Sensor-actuator cable Product Diversity Always the Right Connection Pepperl+Fuchs offers a comprehensive range of sensor-actuator cables for machine and plant installations. In addition to the common M8,
More informationM23 Connectors and cables
Contents Product Description: SAI M23 Connectors.2 Contact assignment.7 Technical data.8 Overview.10 M23 connector for signal transmission.12 M23 connector for power transmission.18 Moulded M23 cables.22
More informationPHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),
Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in
More informationEthernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12
Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables Cable Spools Unshielded Twisted
More informationEC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method
Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available
More informationOperation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit
Fieldbus system DeviceNet Compatible GW unit Operation Manual EX50-GDN URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8-507-89 Fax: +8-598-56 Note: Specifications
More informationFieldbus System (For Input/Output)
Integrated input-output type Fieldbus System (For Input/Output) EX245 Series AIDA* specifications compliant Push Pull s EX123/124/126 EX600 Push Pull s EX500 IP65 One-touch installation and removal Reduced
More informationAccessories. Accessories. Accessories. Pepperl+Fuchs Group. Ukraine: Copyright Pepperl+Fuchs
Accessories Accessories Accessories 0 970 USA: + 0 86 000 Germany: +9 6 776- Ukraine: +8 0-900 www.pe-ko.com.ua Contents, Accessories Accessories 0. Connectors, Cordsets, Splitters Sensor-actuator cable
More informationCONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.
Revised Sept-28-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Instructions CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Kit
More informationEthernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10
Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables 0 Cable Spools Unshielded
More informationAHC System. Specifications. Series MA210 MA310 Positioning Max. transportable mass
AHC System Series Automatic exchange of robot hand tools, FMS (flexible manufacturing system) implemented for assembly lines. The robot hand tools change automatically to accommodate workpieces of different
More informationEthernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B.
Ethernet cabling Contents Page B Ethernet cabling Ethernet cabling overview B 2 Cabling 4-poles B.1 8 B.1 22 Cables B.1 96 Tools B.1 104 Cabling 8-poles B.2 8 B.2 20 Cables B.2 90 Tools B.2 98 B 1 Profile
More informationClassification Enclosure rating Input voltage Type of
Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.
More informationFor situations susceptible to interference and safety-related applications
IEC 60947-5-2 Product description Multi-pole shielded circular connectors. Design according to DIN 43651, all-metal construction, used for control and measurement systems. Connection of shielded cables
More informationAPS4 Inductive Proximity Sensors
APS4 Inductive APS4-S-E-D APS4-S-E2-D APS4-M-E-D APS4-M-E2-D Compact x27 mm plastic DC 4 models available Compact polycarbonate housing; comes with mounting plate High-frequency oscillation type DC 3-wire,
More informationRound Water-resistant Connectors (M8) XS3
Round Water-resistant Connectors () XS Compact, Watertight, Round Connectors Water-resistive, compact connector meets IP67 requirements. Ideal for a wide variety of FA and OA applications. Using connectors
More informationStandard Buccaneer - Ethernet
IP6 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k or compliant PUR / PVC jacket on cable Shielded system or shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB
More informationBKS. Contents Connectors and accessories. Micropulse Transducers
Contents and accessories KS. Connector overview KS. for nalog, Pulse and SSI KS.4 and accessories for CNopen and DeviceNet KS.6 and accessories for PROFIUS-DP interface KS.8 for Profile series KS for nalog,
More informationIndustrial Hydraulics FAQs
Industrial Hydraulics FAQs FAQ Title: Z versus K or K0 in model code Category: Proportional & Servo Valves Sub-Category: Directional Control Valves Bosch Rexroth Corporation Hydraulics 5 City Line Road
More information28mm. Fieldbus System. EX260 Series. IP67 For units with D-sub connector, and when connected to S0700 manifolds, it is IP40. Drives up to 32 solenoids
Fieldbus System EX60 Series (Output device for driving port solenoid valves) Compact 8mm Space-saving Installation RoHS IP67 For units with D-sub connector, and when connected to S0700 manifolds, it is
More information07. har-link Interface Connectors
. Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism
More informationM12x1 Circular Connectors
M12x1 Circular Connectors Agenda 1. Introduction M12x1 Circular Connectors 2. M12x1 X-coded 3. M12x1 D-coded 4. Accessories and Nomenclature 3 / 2015 Product Presentation M12x1 Page 2 M12x1 Circular Connectors
More informationHan-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu
Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18
More informationSENSOR-ACTUATOR-INTEGRATOR (SAI) SERIES
SAI Products SENSOR-ACTUATOR-INTEGRATOR (SAI) SERIES Industrial automation products (junction boxes) designed to be installed directly into your machine application Choice of metal or plastic housing protects
More informationConnecting cables, Ethernet Technical data
Connecting cable NEBC-D12G4 Connecting cable M12 4-pin D-coded Cable lengths 0.5 10 m Suitable for Ethernet General technical data Electrical connection connector, 4-pin,, D-coded connector, RJ45, 8-pin
More informationStandard Buccaneer BUCCANEER FOR POWER
IP8 rating tested at 1.05kg/sq cm (15lb/sq in) 10m depth for weeks and.8kg/sq cm (10lb/sq in) 100m depth for hours IPK, Tested in accordance with DIN 0050/Part IPkk Water and dustproof to IP8 when mated,,,,,,
More informationFISCHER MINIMAX TM SERIES
TECHNICAL SPECIFICATIONS FISCHER TM SERIES Fischer Connectors SA All rights reserved Web version 1.0-03.2016 Changes without prior notice FISCHER TM SERIES KEY FEATURES The Fischer MiniMax Series increases
More informationTechnical Explanation for Wiring Systems
CSM_Connector_TG_E_1_1 Introduction What Is a Wiring System? A Wiring System is a device that is used to convert a connection to a connector to connect (wire) a device or circuit. Converting connections
More informationStandard Buccaneer - Ethernet
IP6 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k or compliant PUR / PVC jacket on cable Shielded system or shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB
More informationReduced wiring system. PROFIBUS-DP Compatible GW unit. Operation Manual EX510-GPR1. URLhttp://www.smcworld.com
Reduced wiring system PROFIBUS-DP Compatible GW unit Operation Manual EX510-GPR1 URLhttp://www.smcworld.com 1 Table of Contents Thank you for purchasing the SMC reduced wiring system EX510 series. Please
More informationComplete the Installation SKINTOP MS-SC. Color Code: Approvals: Nominal Outer Diameter
BUS UNITRONIC BUS PB For PROFIBUS-DP/FMS/FIP bus systems; stationary applications; 150 Ω UNITRONIC BUS PB UNITRONIC BUS PB FC UNITRONIC BUS PROFIBUS cables are designed for automation networks requiring
More informationRound Water-resistant Connectors (M12) XS2
Round Water-resistant Connectors (M) XS Water- and Environment-resistive FA Connectors Save Wiring and Maintenance Effort Compact FA connectors satisfy IP67 requirements and ensure a 9V-0 fire retardant
More informationSupplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376
Supplementary instructions Plug connector Harting HAN 8D for continuously measuring sensors Document ID: 30376 Contents Contents 1 For your safety 1.1 Appropriate use... 3 1.2 Impermissible use... 3 1.3
More information02. PushPull CONNECTORS
. CONNECTORS A distributed automation system does not contain any central automated control cabinets. Controls, sensors and actuators are designed for a high degree of protection (IP 65 / IP 67) and are
More informationFieldbus System (For Input/Output)
Fieldbus System (For Input/) Series RoHS Compatible Protocols New Unit type added Dual port SI Unit (EtherNet/IPTM) product Reduction in wiring time with SPEEDCON (Phoenix Contact). Just insert and make
More informationPHOENIX CONTACT - 01/2008
Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex
More informationM8 & M12 Connector Cables
Page Number egend M8 & M Connector Cables Cordset Initiative Data Sheet XSF-M8 / XSW-M8 / XSF-M / XSW-M XSF M8 Single-Ended XSW M8 Double-Ended 7 XSF M Single Ended 9 XSW M Double-Ended Cordset Number
More informationIP68 Sealed - Mini USB Buccaneer
IP68 Sealed - IP68 Over moulded assembly provides IP68 cable seal Coupling ring, screw thread provides secure cable coupling Mini USB connector O ring maintains IP68 seal at connector interface Mini USB
More informationrevos revos Industrial Multipole Connectors
revos revos Industrial Multipole Connectors Catalog 2018 revos MINI Plant II, Rodezstraße in Bamberg Company headquarters in Bamberg STOCKO main plant in Wuppertal Solutions for Building technology AT
More informationXW3B. Connector Terminal Boxes. Ratings and Specifications. Compatible Connectors. Materials and Finish
es XWB Series Includes New Lightweight, Low-profile Connector Terminal Boxes for Use Outside of Control Boxes to Centralize I/O with Reduced Labor and Greater Environmental Resistance Tough model with
More informationConnector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable
44 Connector Built-in Micro Photoelectric SERIES Related Information General terms and conditions... F-1 Glossary of terms... P.1~ selection guide... P.441~ General precautions... P.140 Amplifier Built-in
More informationSeries LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver
Series LCD To power supply Stepper Motor Driver LCD Electric Actuator Series LCC Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided
More informationCX BD series. Main features MULTIPOLE CONNECTORS CX BD CN
MULTIPOLE CONNECTORS CX BD CN i CX BD series Main features To be able to use round shielded connectors series MIXO BUS (multiaxial, for balanced cables with multiple pairs) or coaxial connectors (for coaxial
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationMating connectors and cable sets for valves and sensors in hydraulics
Mating connectors and cable sets for valves and sensors in hydraulics RE 08006/0. Replaces: 04. /4 Table of contents See page to 5 Features Mating connectors and cable sets for the electrical connection
More information14CESeries. Miniature Pre-Leaded Vertical Enclosed Switches
Miniature Pre-Leaded Vertical Enclosed Switches 14CESeries Miniature enclosed switches with outstanding harsh environment resistance, ideal for compact machinery and equipment. Easy mounting by tightening
More informationInstruction Manual. Reduced wiring system EtherNet/IP Compatible SI Unit EX250-SEN1. URL
Reduced wiring system EtherNet/IP Compatible SI Unit Instruction Manual EX-SEN URL http:// www.smcworld.com Specifications are subject to change without prior notice and any obligation on the part of the
More informationPressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit
Pressure Switch CE0 NEW IR Communication type Pressure Switch Rev. Fluids/Gasses Utilizing Stainless Diaphragm Utilizes stainless steel diaphragm for use with a wide variety of pressure media Excellent
More informationAccessories Bus Terminals
Accessories s Connectors Lightbus Z1000 Z1010 Z1020 standard connector for 1,000 µm plastic fibre standard connector for 200 µm PCS fibre coupling for Z1000 PROFIBUS ZB3100 ZB3101 ZB3102 ZS1031-3000 ZS1031-3500
More informationAccessory Kit for all Designs of Hand-held Pendant Station
Overview of accessories for hand-held pendant station kits Accessories for kit Suitable for all designs Hand-held pendant stations HBA/HBM Hand-held pendant stations HBL EMERGENCY- STOP device Pushbutton
More informationEthernet Media. Technical Data. Bulletin Numbers 1585, 1585A, 1585BP, 1585BT, 1585BX, 1585BZ, 1585D, 1585J
Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Summary of Changes Introduction Cable Spools Unshielded Twisted Pair Shielded Twisted Pair (Foil
More informationSupplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456
Supplementary instructions Plug connector Harting HAN 7D For point level sensors Document ID: 446 Contents Contents For your safety.... Appropriate use.... General safety instructions.... Safety instructions
More informationVMEbus systems System description Technical characteristics System description
Directory chapter 06 / inverse Page VMEbus systems................................................ 06.02 System description.............................................. 06.03 Technical characteristics..........................................
More informationElectrical Interconnection
Electrical Interconnection Edition 208/ Rail-Mount Terminal Block Systems Full Line Catalog, Volume Edition 207/208 PCB Terminal Blocks and Connectors Full Line Catalog, Volume 2 Edition 207/208 2 Automation
More informationSUNCLIX Connection technology for photovoltaics
SUNCLIX Connection technology for photovoltaics Connection technology for photovoltaics Are you looking for innovative and reliable connection technology for your PV modules, inverters or the complete
More informationDoc. No.: EX**-OMC0024. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1 SMC CORPORATION
Doc. No.: EX**-OMC00 Instruction Manual SI Unit / DI Unit EX0-SDN EX0-IE SMC CORPORATION SAFETY INSTRUCTIONS (Read carefully before use.) Thoroughly read this technical instruction manual and related manuals
More informationLevel sensor Stainless steel version Model RLT-1000, for industrial applications
Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring
More informationStandard Series Standard
Standard Series Standard Technical Data Coupler connector, cable connector and coupler connector rectangular housing Locking screw connection Protection IP 50 to IP 54 with conexil in the housing, flat-gasket
More informationTechnical data: Pin Spacing
282 Female Connectors, Double-Row Pin Spacing: 3.5 mm Universal connection for all conductor types Unique, compact, double-row connector system for conductor cross sections up to 1.5 mm 2 High-density,
More informationGA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations
875 PHOTO PHOTO IT FOW PARTICUAR Compact Inductive Proximity Sensor -separated GA- SERIES General terms and conditions... F-7 Related Information Glossary of terms... P.482~ Sensor selection guide... P.80~
More informationProportional reducing valves type AGRCZO-AES two stages, normally closed, without integral pressure transducer, ISO 5781 size 10 and 20
www.atos.com Table F050-8/E Proportional reducing valves type AGRCZO-AES two stages, normally closed, without integral pressure transducer, ISO 5781 size 10 and 20 Main poppet Pilot relief valve type RZMO
More informationGX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available
8 Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.86~ selection guide... P.757~ General precautions... P.05 PHOTO PHOTO Conforming
More informationItem No.: /
mounting adapter also for DIN 35 rail; % protected against mismating; Plate thickness 06x12 mm; Male connector; with snap-in mounting foot; 4-pole; pin spacing 35 mm / 0138 in; with 209-137 mounting adapter
More information3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.
2-Color Display High-Precision Digital Pressure Switch ZSE3A(F)/E3A Series RoHS Can copy to up to 1 switches simultaneously. setting labor Minimizing ZSE3 E3 ZSE4 E4 The settings of the master sensor can
More informationPlug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs
1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector
More informationSales: Technical: Fax:
DATA SHEET Weatherproof Order code Manufacturer code Description 23-2650 PX0410/02S/5560 2 WAY FREE SOCKET MICRO BUCCANNEER 23-2652 PX0410/03S/5560 3 WAY FREE SOCKET MICRO BUCCANNEER (RC) 23-2654 PX0410/04S/4550
More informationDatasheet. Datasheet-No Type: RS(W)T(S) - RK(W)T(S) -.../ M. Page: 1 of 7
The information/details in this datasheet merely contain general descriptions or performance factors which, when applied in an actual situation, do not always correspond with the described form, and may
More informationEN3 SERIES WEATHERTIGHT CONNECTORS NEW PRODUCT BULLETIN 602
FEATURES & BENEFITS Sealed to IP68 NEMA 250 (6P) Patented grommet & o-ring free design Available in ribbed or winged coupling ring Cable, panel & cable to cable options Gold plated contacts standard Solder,
More informationContents 9-1. Network Media
Contents General Information Quick Selection Guide... page 9--2 Introduction... page 9--3 Ethernet Media Cordsets & Patchcords Cable Spools... page 9--4 Cordsets & Patchcords... page 9--5 Field Attachable
More informationXS2. Water- and Environmentresistive. Wiring and Maintenance Effort. Sensor I/O Connectors (M12) Construction (XS2G Soldering Plug Connector Assembly)
I/O (M) XS XS/XS /XW XS XN XWB XS XS Water- and Environmentresistive FA Save Wiring and Maintenance Effort Compact FA connectors satisfy IP67 requirements and ensure a 9V-0 fire retardant rating. A wide
More informationPHOENIX CONTACT
Fast connection connector for PROFIBUS systems Data sheet 101610_en_07 PHOENIX CTACT 2011-11-17 1 Description The D-SUB series SUBC-PLUS-PROFIB is specially designed for use in PROFIBUS systems up to 12
More information