EX120/121/122 Series Some protocols are not CE-compliant.

Size: px
Start display at page:

Download "EX120/121/122 Series Some protocols are not CE-compliant."

Transcription

1 Output type for solenoid valves (For Output) EX120/121/122 Series Compatible Protocols CompoBus/S NKE Corp.: Fieldbus H System Made to Order Small unit compatible with a maximum of 16 outputs Compatible with a variety of communication networks EX120 Series S-Link V Manifold Solenoid Valves SV1000/2000/3000/4000 VQ1000/2000 SY3000/5000/7000 * Some protocols are not CE-compliant. Refer to How to Order. EX600 EX500 EX123/124/126 EX260 D D D D D D EX121 Series SY3000/5000 EX122 Series SY3000/5000 EX250 EX120/121/122 EX245 CONTENTS Output type for solenoid valves (For Output) EX120/121/122 Series EX120 EX121 EX122 How to Order SI Unit p. 173 Specifications p. 174 Dimensions/Parts Description p. 175 LED Indicator p. 178 Accessories q Communication Connector p. 179 w Power Supply Connector p. 179 Made to Order qdevicenet TM PNP (Negative common) output, Occupied points: 16 inputs/16 outputs p. 179 wdevicenet TM PNP (Negative common) output, Occupied points: 0 inputs/16 outputs p. 179 e S-LINK V compatible NPN (Positive common) 16 outputs p. 179 Specific Product Precautions p ATEX M8/M12 EX510 EX180 EX140

2 For Output EX120/121/122 Series Some protocols are not CE-compliant. How to Order SI Unit EX12 0 S DN1 Valve interface 0 Plug-in 1 Flat ribbon cable DIN rail mounting 2 Plug-in DIN rail mounting Made to Order (Refer to page 179.) Protocol Output polarity Occupied points DeviceNet DeviceNet S-LINK V PNP (Negative common) PNP (Negative common) NPN (Positive common) 16 inputs/ 16 outputs 0 inputs/ 16 outputs 0 inputs/ 16 outputs Protocol CE-compliant DN1 DeviceNet 1 DN1-X26 2 DeviceNet 1 MJ1 CC-Link CS1 OMRON Corp.: CompoBus/S (16 outputs) CS2 OMRON Corp.: CompoBus/S (8 outputs) UH1 NKE Corp.: Fieldbus H System CM1 CompoNet NPN (Positive common) CM3 CompoNet PNP (Negative common) 1 DN1 s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16 outputs. 2 A manifold part number is not specified for this model. Please contact SMC for the manifold integrated type. 173

3 For Output EX120/121/122 Series Specifications Common Specifications Communication Terminating resistor Not provided Internal current consumption (Unit) 100 ma or less Enclosure IP20 Environment Communication Operating temperature range Operating humidity range Withstand voltage Insulation resistance Model EX12 -SDN1 EX12 -SDN1-X26 EX12 -SMJ1 EX12 -SCS1 EX12 -SCS2 Protocol DeviceNet CC-Link OMRON Corp.: CompoBus/S Version 1 Release 2.0 Ver Communication speed 125 k/250 k/500 kbps 156 k/625 kbps 2.5 M/5 M/10 Mbps Configuration file 2 EDS file CSP+ file I/O occupation area (Inputs/Outputs) 0 to 55 C (Valve 8 points ON) 0 to 50 C (Valve 16 points ON) 35 to 85%RH (No condensation) 1500 VAC for 1 minute between whole external terminal and enclosure 2 MΩ or more (500 VDC) between whole external terminal and enclosure 16/16 0/16 32/32 (1 station, remote I/O stations) 750 kbps SCS1: 0/16 SCS2: 0/8 Power supply For control 11 to 25 VDC 15 to 30 VDC 14 to 26.4 VDC voltage For valve 24 VDC +10%/ 5% Output type Sink/NPN (Positive common) SCS1: 16 points Number of outputs 16 points SCS2: 8 points Output Load Solenoid valve with surge voltage suppressor 24 VDC, 2.1 W or less (SMC) Fail safe CLEAR HOLD/CLEAR HOLD/CLEAR CLEAR (Switch setting) (Switch setting) Standards CE marking Weight EX120: 110 g or less, EX121: 140 g or less, EX122: 130 g or less Accessory Communication connector 1 pc., Power supply connector 1 pc. 1 Please note that the version is subject to change. 2 The setting file can be downloaded from the SMC website, EX250 EX245 EX600 EX500 EX123/124/126 EX260 Model EX12 -SUH1 EX12 -SCM1 EX12 -SCM3 Protocol NKE Corp.: Fieldbus H System CompoNet Communication Communication speed 29.4 kbps kbps/1.5 M/3 M/4 Mbps Configuration file EDS file 1 I/O occupation area (Inputs/Outputs) 0/16 Power supply For control 24 VDC ±10% 14 to 26.4 VDC voltage For valve (Common power supply) 24 VDC +10%/ 5% Output type Sink/NPN (Positive common) Sink/NPN (Positive common) Source/PNP (Negative common) Output Number of outputs 16 points Load Solenoid valve with surge voltage suppressor 24 VDC, 2.1 W or less (SMC) Fail safe CLEAR HOLD/CLEAR (Setting via network) Standards CE marking Weight EX120: 110 g or less EX121: 140 g or less EX122: 130 g or less EX120: 100 g or less EX121: 120 g or less EX122: 110 g or less (including accessory) Accessory Power supply connector (EX9-CP2) 1 pc. 2 1 The setting file can be downloaded from the SMC website, 2 Communication connector (for the opposite side) is not provided. EX510 EX180 EX140 EX120/121/122 ATEX M8/M12 174

4 PWR(V) MS EX120/121/122 Series Dimensions/Parts Description EX120 EX120-SDN1(-X26) EX120-SMJ1, SCS, SUH1 Terminal block cover Terminal block cover Power supply connector Communication connector Screw terminal block EX120-SCM Terminal block cover NS SETTINGS 10 1 OUT 24V 0V FG BS+ BDH BDL BS- 5.4 Power supply connector Communication connector

5 PWR(V) MS For Output EX120/121/122 Series Dimensions/Parts Description EX121 EX121-SDN1(-X26) EX121-SMJ1, SCS, SUH1 Position indicator LED EX260 Terminal block cover Terminal block cover EX123/124/ Power supply connector MIL connector (20 pins, socket) Communication connector Tightening torque 0.6 N m MIL connector (20 pins, socket) Screw terminal block Tightening torque 0.6 N m EX245 EX500 EX DIN rail mounting bracket DIN rail mounting bracket EX250 EX121-SCM Position indicator LED Terminal block cover EX120/121/122 SETTINGS NS OUT V 0V FG BS+ BDH BDL BS- EX140 Power supply connector MIL connector (20 pins, socket) EX Communication connector Tightening torque 0.6 N m EX510 M8/M DIN rail mounting bracket ATEX 176

6 BS- EX120/121/122 Series Dimensions/Parts Description EX122 EX122-SDN1(-X26) EX122-SMJ1, SCS, SUH1 Terminal block cover Terminal block cover Power supply connector 5.4 Communication connector 6.2 Screw terminal block Tightening torque 0.6 N m Tightening torque 0.6 N m DIN rail mounting bracket DIN rail mounting bracket EX122-SCM Terminal block cover PWR(V) MS NS SETTINGS 10 1 OUT 24V 0V FG BS+ BDH BDL Power supply connector Communication connector Tightening torque 0.6 N m 64 DIN rail mounting bracket

7 TM For Output EX120/121/122 Series LED Indicator EX12 -SDN1 EX12 -SMJ1 PWR: Power supply for control MOD/NET: Connection state PW: Power supply for control LRUN: Communication state EX260 24V MOD/NET PWR SERIAL UNIT 0V V- SETTINGS 1 0 MODELSQ(SI No.EX120-SDN1) CANL FG CANH V+ SD RD SMC SERIAL UNIT 24V 0V +24V 24G LERR. B RATE PW LRUN STATION NO DA DB DG FG EX123/124/126 LERR: Error RD: Data reception SD: Data transmission EX500 EX12 -SCS EX12 -SUH1 PWR: Power supply for control COMM: Communication state ERR: Communication error POWER: Power supply for control COMM: Communication state EX245 BS+ ADDRESS NO. PWR COMM ERR 1 0 SERIAL UNIT BDH BDL BS- FG 24V 0V No. 24V POWER SEND SERIAL UNIT 0V D G ADDRESS ON OFF MODEL SH (SINO.EX120-SUH1) D G 24V 0V EX12 -SCM PWR(V): Power supply for valve MS: SI unit state NS: Network error PWR(V) MS NS WORD NODE ADDRESS 10 1 OUT 24V 0V FG BS+ BDH BDL BS- ATEX EX140 EX250 EX120/121/122 EX600 EX180 EX510 M8/M12 178

8 EX120/121/122 Series Accessories (For EX12 -SCM ) q Communication Connector Press-in connector for flat cables Use this connector for the standard dedicated flat cable. The communication connector does not come with this product. EX9-CCM1 Black Cable identification label (Flat cable: Black, Blue, White, Red) w Power Supply Connector Straight type power supply connector This connector is supplied at the time of shipment. EX9-CP2 Lock lever Terminal block connector for round cables (VCTF) Use this connector for the VCTF cable. The communication connector does not come with this product. EX9-CCM2 T-branch type power supply connector This connector is not supplied at the time of shipment. EX9-CP3 Lock lever Cable identification label (Flat cable: Black, Blue, White, Red) Black Made to Order Please contact SMC for detailed specifications and lead times. Prepare the SI unit and manifold valve (without SI unit) separately, and combine them before use. qdevicenet PNP (Negative common) output, Occupied points: 16 inputs/16 outputs EX12 0 -SDN1-X2 Valve interface 0 Plug-in 1 Flat ribbon cable DIN rail mounting 2 Plug-in DIN rail mounting wdevicenet PNP (Negative common) output, Occupied points: 0 inputs/16 outputs EX12 0 -SDN1-X77 Valve interface 0 Plug-in 1 Flat ribbon cable DIN rail mounting 2 Plug-in DIN rail mounting Dimensions are the same as those of the standard type. Dimensions are the same as those of the standard type. e S-LINK V compatible NPN (Positive common) 16 outputs EX120-SSL1-X99 Dimensions are the same as those of the CC-Link (EX120-SMJ1). Specific Product Precautions Be sure to read this before handling the products. Refer to page 277 for safety instructions. For fieldbus system precautions, refer to pages 278 to 280 and the Operation Manual on the SMC website: A Operating Environment Warning 1. Do not use this product in the presence of dust, particles, water, chemicals, and oil. Use around such materials is likely to cause a malfunction or breakage. 179 Trademark DeviceNet is a trademark of ODVA. CompoNet is a trademark of ODVA.

9 Output type for solenoid valves (For Output) EX124), IP67 (EX126) Enclosure IP65 (EX123, Maximum 16 outputs EX124 Series VQ2000/4000/5000 VQ2000/4000/5000 EX123 Series EX600 Manifold Solenoid Valves EX126 Series SV1000/2000/3000 VQC1000/2000/4000/5000 EX124 EX126 Accessories q Replacement Fuse w Drip Proof Plug Assembly p. 52 p. 52 Made to Order q DeviceNet PNP (Negative common), Occupied points: 16 inputs/16 outputs w DeviceNet PNP (Negative common), Occupied points: 0 inputs/16 outputs e CompoNet r Signal Cut Block Specific Product Precautions p. 53 p. 53 p. 53 p. 53 p EX140 EX510 EX123 p. 49 p. 50 p. 51 p. 52 M8/M12 (For Output) EX123/124/126 Series How to Order SI Unit Specifications Dimensions/Parts Description LED Indicator ATEX Output type for solenoid valves CONTENTS EX180 EX120/121/122 EX250 SY3000/5000/7000 EX500 Made to Order EX245 CompoBus/S NKE Corp.: Fieldbus H System nly the EX124 * O and EX126 series are CE-compliant. Compatible Protocols EX123/124/126 EX260 EX123/124/126 Series

10 For Output EX123/124/126 Series How to Order SI Unit * Only the EX124 and EX126 series are CEcompliant. EX12 3 U S UH1 3 Unit specifications Common power supply of control and valve Enclosure IP65 Compatible with the VQ valves Protocol CE-compliant UH1 NKE Corp.: Fieldbus H System U D Mounting specifications Mount a unit to the U side of the manifold Mount a unit to the D side of the manifold EX12 4 U S DN1 4 Unit specifications Separate power supply of control and valve Enclosure IP65 Compatible with the VQ valves U D Mounting specifications Mount a unit to the U side of the manifold Mount a unit to the D side of the manifold Made to Order (Refer to page 53.) Protocol Output polarity Occupied points DeviceNet DeviceNet PNP (Negative common) PNP (Negative common) 16 inputs/ 16 outputs 0 inputs/ 16 outputs Protocol CE-compliant DN1 DeviceNet *1 DN1-X26 DeviceNet *1 MJ1 CC-Link CS1 OMRON Corp.: CompoBus/S (16 outputs) CS2 OMRON Corp.: CompoBus/S (8 outputs) *1 DN1 s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16 outputs. EX12 6 D S MJ1 6 Unit specifications Separate power supply of control and valve Enclosure IP65 Compatible with the SY/SV/VQC valves D Mounting specifications Mount a unit to the D side of the manifold Protocol CE-compliant MJ1 CC-Link 49

11 For Output EX123/124/126 Series Specifications Common Specifications Communication Terminating resistor Not provided Internal current consumption (Unit) 100 ma or less Output Output type Sink/NPN (Positive common) Load Solenoid valve with surge voltage suppressor 24 VDC, 2.1 W or less (SMC) Operating temperature 0 to 55 C (Valve 8 points ON) range 0 to 50 C (Valve 16 points ON) Environmental Operating humidity range 35 to 85%RH (No condensation) resistance Withstand voltage 1500 VAC for 1 minute between whole external terminal and enclosure Insulation resistance 2 MΩ or more (500 VDC) between whole external terminal and enclosure Weight 240 g or less Accessory 4 unit mounting screws (M4 x 10) EX260 EX123/124/126 Model EX123 -SUH1 EX124 -SDN1 EX124 -SDN1-X26*3 Applicable Protocol NKE Corp.: Fieldbus H System DeviceNet DeviceNet system Version*1 Release 2.0 Communication Communication speed 29.4 kbps 125 k/250 k/500 kbps Configuration file*2 EDS file I/O occupation area (Inputs/Outputs) 0/16 16/16 0/16 Power supply For control 24 VDC ±10% 11 to 25 VDC voltage For valve (Common power supply) 24 VDC +10%/ 5% Number of outputs 16 points Output Fail safe CLEAR HOLD/CLEAR (Switch setting) Environment Enclosure IP65 Standards CE marking Communication Model Applicable system EX124 -SMJ1 EX124 -SCS1 EX124 -SCS2 EX126D-SMJ1 Protocol CC-Link OMRON Corp.: CompoBus/S CC-Link Version*1 Ver Ver Communication speed 156 k/625 kbps 2.5 M/5 M/10 Mbps 750 kbps 156 k/625 kbps 2.5 M/5 M/10 Mbps Configuration file*2 CSP+ file CSP+ file I/O occupation area (Inputs/Outputs) 32/32 (1 station, remote I/O stations) SCS1: 0/16 SCS2: 0/8 32/32 (1 station, remote I/O stations) Power supply For control 15 to 30 VDC 14 to 26.4 VDC 15 to 30 VDC voltage For valve 24 VDC +10%/ 5% SCS1: 16 points Number of outputs 16 points Output SCS2: 8 points 16 points Fail safe CLEAR HOLD/CLEAR (Switch setting) CLEAR Environment Enclosure IP65 IP67 Standards CE marking *1 Please note that the version is subject to change. *2 The setting file can be downloaded from the SMC website, *3 Since this is a special product, a manifold part number is not specified. Please consult SMC for the manifold integrated type. * For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website, ATEX M8/M12 EX180 EX140 EX120/121/122 EX250 EX245 EX600 EX500 EX510 50

12 EX123/124/126 Series Dimensions/Parts Description EX123 -S, EX124 -S Wiring entry (There is no case for the EX123 type.) Screw terminal block Housing cover Housing cover diagram 19 (72.5) EX123 : 2 x G1/2 EX124 : 4 x G1/2 Wiring entry * The housing cover of the EX124U/D-SMJ1 is the same as that of the EX126D-SMJ1. EX126D-SMJ1 Screw terminal block 114 Housing cover diagram Housing cover (72.5) Power supply fuse for valve EX9-FU x G1/2 Wiring entry Power supply fuse for control EX9-FU Housing bottom diagram

13 For Output EX123/124/126 Series LED Indicator EX123m-SUH1 EX124m-SDN1 SEND: Transmission state POWER: Power supply for control MOD/NET: Connection state PWR: Power supply for control EX123/124/126 EX124m-SMJ1 EX124m-SCSm EX500 RD: Data reception SD: Data transmission LERR: Error EX126D-SMJ1 LRUN: Communication state PW: Power supply for control ERR: Communication error PWR: Power supply for control COMM: Communication state EX250 PW: Power supply for control LERR: Error LRUN: Communication state SD: Data transmission RD: Data reception Accessories q Replacement Fuse A replacement fuse for the EX126D-SMJ1 EX9-FU20 Applicable model EX126D-SMJ1 Rated current 2.0 A Fuse w Drip Proof Plug Assembly Use when the wiring entry (G1/2) is not being used. Incorrect handling of the wiring entry may allow foreign matter to enter the SI unit, which will lead to a malfunction and damage to the SI unit. AXT100-B04A ATEX EX180 EX140 EX120/121/122 EX510 M8/M12 EX245 EX600 EX260 52

14 EX123/124/126 Series Made to Order q DeviceNet PNP (Negative common), Occupied points: 16 inputs*1 /16 outputs EX124 U -SDN1-X2 Mounting specifications U Mount a unit to the U side of the manifold D Mount a unit to the D side of the manifold Dimensions are the same as those of the standard type. Please contact SMC for detailed specifications and lead times. Prepare the SI unit, signal cut block, and manifold valve (without SI unit) separately, and combine them before use. *1 The SI unit cannot be connected to an input device but occupies memory areas of 16 input points (2 bytes) as a mirror function of output data. The mirror function is used to transmit output data received by the SI unit as input data exactly as it is. w DeviceNet PNP (Negative common), Occupied points: 0 inputs/16 outputs EX124 U -SDN1-X77 Mounting specifications U Mount a unit to the U side of the manifold D Mount a unit to the D side of the manifold Dimensions are the same as those of the standard type. ecomponet Please contact SMC for details. rsignal cut block EX9-SC1-8 A switch unit that forcibly turns OFF the output signal to the valve by means of a toggle switch operation in double 1-station units Open the switch guard to prevent misoperation, and then carry out the operation. It comes with a safety mechanism which returns the switch to the normal position (AUTO) after the switch guard is closed. Enclosure: IP67 Example of connections Switch Connector connection Cover open Hook Switch guard (Part no.: EX9- HCDSC1-X42) VQC valve Signal cut block (EX9-SC1-8) SI unit EX126 (CC-Link compliant) Press the lever to open the switch guard. To close the switch guard, press the lever and attach the hook. Cover closed Switch guard (Part no.: EX9- HCDSC1-X42) Specific Product Precautions Be sure to read this before handling the products. Refer to page 277 for safety instructions. For fieldbus system precautions, refer to pages 278 to 280 and the Operation Manual on the SMC website: smcworld.com Trademark DeviceNet is a trademark of ODVA. CompoNet is a trademark of ODVA. A 53 Operating Environment Caution 1. Select the proper type of enclosure according to the operating environment. IP65/67 is achieved when the following conditions are met. 1) Provide appropriate wiring between all units using electrical wiring cables and communication connectors cables. 2) For wiring, use a G1/2 cable gland. 3) Appropriately mount each unit and valve manifold. 4) Be sure to install a drip proof plug assembly (AXT100-B04A) on each unused connector. This is to prevent the risk of the SI unit malfunctioning or breaking down. If using in an environment that is exposed to water splashes, please take measures such as using a cover.

15 Output type for solenoid valves (For Output) EX140 Series Compatible Protocols CompoBus/S NKE Corp.: Fieldbus H System Thinner unit with low height Maximum 16 outputs Some protocols are not CE-compliant. Refer to How to Order. SZ3000 Manifold Solenoid Valves SQ1000/2000 EX140 EX120/121/122 EX500 EX123/124/126 EX260 EX250 EX600 EX245 CONTENTS Output type for solenoid valves (For Output) EX140 Series How to Order SI Unit p. 181 Specifications p. 181 Dimensions/Parts Description p. 182 LED Indicator p. 183 Specific Product Precautions p. 183 ATEX M8/M12 EX510 EX

16 For Output EX140 Series Some protocols are not CE-compliant. How to Order SI Unit EX140 S DN1 Protocol CE-compliant DN1 DeviceNet MJ1 CC-Link CS1 OMRON Corp.: CompoBus/S (16 outputs) CS2 OMRON Corp.: CompoBus/S (8 outputs) UH1 NKE Corp.: Fieldbus H System Specifications Communication Power supply voltage EX140-SCS1 EX140-SCS2 Protocol DeviceNet CC-Link OMRON Corp.: CompoBus/S Version 1 Release 2.0 Ver k/250 k/500 kbps 156 k/625 kbps 2.5 M/5 M/10 Mbps Model EX140-SDN1 EX140-SMJ1 Applicable system Communication speed EX140-SUH1 NKE Corp.: Fieldbus H System 750 kbps 29.4 kbps Configuration file 2 EDS file CSP+ file I/O occupation area (Inputs/Outputs) Terminating resistor 0/16 32/32 (1 station, remote I/O stations) Not provided SCS1: 0/16 SCS2: 0/8 For control 11 to 25 VDC 15 to 30 VDC 14 to 26.4 VDC 24 VDC ±10% For valve 24 VDC +10%/ 5% (Common power supply) 100 ma or less Output type Sink/NPN (Positive common) Number of outputs 16 outputs SCS1: 16 outputs SCS2: 8 outputs 16 outputs Load Solenoid valve with surge voltage suppressor 24 VDC, 2.1 W or less (SMC) Fail safe HOLD/CLEAR (Switch setting) CLEAR Enclosure IP20 Internal current consumption (Unit) Output Environmental resistance Operating temperature range Operating humidity range Withstand voltage Insulation resistance 0 to 55 C (Valve 8 points ON) 0 to 50 C (Valve 16 points ON) 35 to 85%RH (No condensation) 1500 VAC for 1 minute between whole external terminal and enclosure 2 MW or more (500 VDC) between whole external terminal and enclosure Standards CE marking Weight 80 g or less Communication connector 1 pc., Accessory Power supply connector 1 pc. 1 Please note that the version is subject to change. 2 The setting file can be downloaded from SMC website, For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website, 0/16 181

17 For Output EX140 Series Dimensions/Parts Description EX140-SDN (11.5) 34.4 (36) Power supply connector Communication connector EX140-SMJ1, SCS, SUH M3 Screw terminal block 34.4 ATEX M8/M12 EX510 EX500 EX600 EX250 EX120/121/122 EX140 EX180 EX245 EX123/124/126 EX

18 TM EX140 Series LED Indicator EX140-SDN1 EX140-SMJ1 POWER: Power supply for control MOD/NET: Connection state PWR: Power supply for control L RUN: Communication state SERIAL UNIT EX140-SDN1 POWER MOD/NET SETTINGS SERIAL UNIT PWR. L RUN L ERR. SD RD B RATE STATION No. 24V 0V V- CAN L FG CAN H V+ 24V V +24V 24G DA DB DG FG Solenoids L ERR: Error RD: Data reception SD: Data transmission EX140-SCS EX140-SUH1 PWR: Power supply for control COMM: Communication state ERR: Communication error POWER: Power supply for control SEND: Communication state SERIAL UNIT EX140-SCS1 PWR. COMM ERR. ADDRESS No. SERIAL UNIT EX140-SUH1 POWER SEND ADDRESS BS+ BDH BDL BS- FG 24V 0V 24V 0V D G D G 24V 0V No. Specific Product Precautions Be sure to read this before handling the products. Refer to page 277 for safety instructions. For fieldbus system precautions, refer to pages 278 to 280 and the Operation Manual on the SMC website: Operating Environment Warning 1. Do not use this product in the presence of dust, particles, water, chemicals, and oil. Use around such materials is likely to cause a malfunction or breakage. 183 Trademark DeviceNet is a trademark of ODVA.

19 Output type for solenoid valves (For Output) EX180 Series Compatible Protocols Made to Order AnyWireASLINK Thinner unit with low height Maximum 32 outputs Manifold Solenoid Valves Only the SJ valve is UL-compliant. SJ2000/3000 S0700 EX140 EX500 EX123/124/126 EX260 EX120/121/122 EX250 EX600 EX245 CONTENTS Output type for solenoid valves (For Output) EX180 Series How to Order SI Unit p. 185 Specifications p. 185 Dimensions/Parts Description p. 186 LED Indicator p. 187 Accessories q Communication Connector p. 187 w Power Supply Connector p. 187 Made to Order qethercat PNP (Negative common), 32 outputs p. 188 wanywireaslink NPN (Positive common), 32 outputs p. 188 Specific Product Precautions p ATEX M8/M12 EX510 EX180

20 For Output EX180 Series Only the SJ valve is UL-compliant. How to Order SI Unit EX180 S DN3 Specifications DN3 DN4 DN5 DN6 MJ3 MJ5 Protocol DeviceNet (32 points Sink/NPN (Positive common)) DeviceNet (16 points Sink/NPN (Positive common)) DeviceNet (32 points Source/PNP (Negative common)) DeviceNet (16 points Source/PNP (Negative common)) CC-Link (32 points Sink/NPN (Positive common)) CC-Link (32 points Source/PNP (Negative common)) Made to Order (Refer to page 188.) Protocol EtherCAT AnyWireASLINK Communication connector type Nil T-branch type A Straight type Communication and power supply connectors are included. Communication Model EX180-SDN3 EX180-SDN4 EX180-SDN5 EX180-SDN6 EX180-SMJ3 Applicable Protocol DeviceNet CC-Link system Version 1 Release 2.0 Ver Communication speed 125 k/250 k/500 kbps 156 k/625 kbps 2.5 M/5 M/10 Mbps Configuration file 2 EDS file CSP+ file I/O occupation area (Inputs/Outputs) SDN3: 0/32 SDN4: 0/16 SDN5: 0/32 SDN6: 0/16 32/32 (1 station) EX180-SMJ5 Terminating resistor Not provided Built into the unit (Switch setting, 110 W) Power supply For control 11 to 25 VDC 24 VDC ±10% voltage For valve 24 VDC ±10%/ 5% Internal current consumption (Unit) 0.1 A or less Output type Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Output Environmental resistance Standards Weight Accessory Number of outputs Load SDN3: 32 outputs SDN4: 16 outputs SDN5: 32 outputs SDN6: 16 outputs SJ2000/3000, S0700 series manifold valves 32 outputs Fail safe HOLD/CLEAR (Switch setting) Enclosure IP20 Operating temperature range 10 to 50 C Operating humidity range 35 to 85%RH (No condensation) Withstand voltage 500 VAC for 1 minute between whole external terminal and FG Insulation resistance 10 MW or more (500 VDC) between whole external terminal and FG CE marking, UL (CSA) 110 g or less (including accessory) Communication connector 1 pc., Power supply connector 1 pc. Communication connector 1 pc., Power supply connector 2 pcs. 1 Please note that the version is subject to change. 2 The setting file can be downloaded from SMC website, For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website, The EX180-SDN1l/2l cannot be mounted on the manifold for the EX180-SDN3l/4l/5l/6l. Additionally, the EX180-SDN3l/4l/5l/6l cannot be mounted on the manifold for the EX180-SDN1l/2l. The EX180-SMJ1l cannot be mounted on the manifold for the EX180-SMJ3l/5l. Additionally, the EX180-SMJ3l/5l cannot be mounted on the manifold for the EX180-SMJ1l. 185

21 For Output EX180 Series Dimensions/Parts Description EX180-SDN Communication connector Power supply connector (For valve) (39.7) 30.9 EX500 EX123/124/126 EX260 M3 Ground terminal Before mounting connector (accessory) EX245 EX180-SMJ Communication connector Power supply connector (For control) EX120/121/ EX140 EX250 EX Power supply connector (For valve) EX180 (39.7) 30.9 M3 Ground terminal Before mounting connector (accessory) EX510 ATEX M8/M12 186

22 EX180 Series LED Indicator EX180-SDN EX180-SMJ PWR(V): Power supply for valve PWR: Power supply for control PWR(V): Power supply for valve PWR: Power supply for control MNS: Connection state L RUN: Communication state L RUN: Error Accessories q Communication Connector Connector for the network cable This connector is supplied at the time of shipment. EX180-C DN 1 w Power Supply Connector Connector for power supply This connector is supplied at the time of shipment. EX180-CP1 Communication protocol DN For EX180-SDN MJ For EX180-SMJ Communication connector type 1 T-branch type 2 Straight type EX180-C 1 EX180-C 2 187

23 EX180-SEC5-X230 For Output EX180 Series Made to Order Please contact SMC for detailed specifications and lead times. Prepare the SI unit and manifold valve (without SI unit) separately, and combine them before use. q EtherCAT PNP (Negative common), 32 outputs EX180-SEC5-X230 The communication connector and power supply connector do not come with this product. (When the SI unit is removed) (10.3) EtherCAT Communication connector (OUT) EtherCAT Communication connector (IN) Ground terminal (M3) Output connector (50 pins) A2 A1 B2 B1 SI 24V SI 0V EX260 SV 24V SV 0V EX123/124/126 Power supply connector (PWR1) (PWR2) Lock plate 39.5 EX600 EX500 EX9-CP6-X27 Power supply connector for the EX180-SEC5-X230 This connector is not supplied at the time of shipment. The minimum ordering quantity of this product is one box (50 pcs. included) EX245 EX250 w AnyWireASLINK NPN (Positive common), 32 outputs EX180-SAW1-X237 EX180-SAW1-X Communication connector EX120/121/ (44.2) EX140 (39.7) 30.9 M3 Ground terminal EX180 Before mounting connector (accessory) Specific Product Precautions EX510 Be sure to read this before handling the products. Refer to page 277 for safety instructions. For fieldbus system precautions, refer to pages 278 to 280 and the Operation Manual on the SMC website: Operating Environment Warning 1. Do not use this product in the presence of dust, particles, water, chemicals, and oil. Use around such materials is likely to cause a malfunction or breakage. Trademark DeviceNet is a trademark of ODVA. EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. 188 A M8/M12 ATEX

For Output. Series EX120/121/122. Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks

For Output. Series EX120/121/122. Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks D D D D D D For Output Series EX120/121/122 Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks Series EX120 Series EX121 Series EX122 SV1000/2000/3000/4000

More information

EX12 -SCS1 EX12 -SCS2 EX12 -SSL1. SSL1: 0/16 SSL2: 0/8 Not provided 11 to 25 VDC 15 to 30 VDC 14 to 26.4 VDC 24 VDC+10%/ 5% 24 VDC+10%/ 5%

EX12 -SCS1 EX12 -SCS2 EX12 -SSL1. SSL1: 0/16 SSL2: 0/8 Not provided 11 to 25 VDC 15 to 30 VDC 14 to 26.4 VDC 24 VDC+10%/ 5% 24 VDC+10%/ 5% D D D D D D For Output Series EX120/121/122 Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks Series EX120 Series EX121 Series EX122 SV1000/2000/3000/4000

More information

Series EX120/121/122. Integrated Type/For Output. How to Order SI Unit SV1000/2000/3000/4000 SY3000/5000 SY3000/5000 VQ1000/2000.

Series EX120/121/122. Integrated Type/For Output. How to Order SI Unit SV1000/2000/3000/4000 SY3000/5000 SY3000/5000 VQ1000/2000. Integrated Type/For Output Series EX120/121/122 Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks Series EX120 SV1000/2000/3000/4000 Series EX121 SY3000/5000

More information

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm Fieldbus System (Output device for driving port solenoid valves) Compact 8mm (Actual size) Space-saving Installation Daisy-chain wiring communication New IP67 For units with D-sub connector, and when connected

More information

Fieldbus System (For Input/Output)

Fieldbus System (For Input/Output) Integrated input-output type Fieldbus System (For Input/Output) EX245 Series AIDA* specifications compliant Push Pull s EX123/124/126 EX600 Push Pull s EX500 IP65 One-touch installation and removal Reduced

More information

Doc. No.: EX**-OMC0024. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1 SMC CORPORATION

Doc. No.: EX**-OMC0024. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1 SMC CORPORATION Doc. No.: EX**-OMC00 Instruction Manual SI Unit / DI Unit EX0-SDN EX0-IE SMC CORPORATION SAFETY INSTRUCTIONS (Read carefully before use.) Thoroughly read this technical instruction manual and related manuals

More information

Information. EX260 Integrated Type (For Output) Serial Transmission System 5 Port Solenoid Valve mm. Series SY/SV/VQC/S0700

Information. EX260 Integrated Type (For Output) Serial Transmission System 5 Port Solenoid Valve mm. Series SY/SV/VQC/S0700 Information Akihabara UX F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN URL http://www.smcworld.com 00 SMC Corporation All Rights Reserved 09-E6 -N Printing OT 0KS EX60 Integrated Type (For Output) Serial

More information

: EX##-OMC0024-A. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1

: EX##-OMC0024-A. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1 : EX##-OMC00-A Instruction Manual SI Unit / DI Unit EX0-SDN EX0-IE SAFETY INSTRUCTIONS (Read carefully before use.) Thoroughly read this technical instruction manual and related manuals mentioned here

More information

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit Fieldbus system DeviceNet Compatible GW unit Operation Manual EX50-GDN URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8-507-89 Fax: +8-598-56 Note: Specifications

More information

Step Motor Controller

Step Motor Controller INFORMATION Step Motor Controller New New New Type Type RoHS Type Type Two types of operation command Transition wiring of communication cables Step no. defined operation: Operate using the preset step

More information

Step Motor Controller

Step Motor Controller INFORMATION Step Motor Controller New New New Type Type RoHS Type Type Two types of operation command Transition wiring of communication cables Step no. defined operation: Operate using the preset step

More information

Step Motor Controller

Step Motor Controller INFORMATION Step Motor Controller RoHS 5 types of communication protocols New Application Communication protocol Can be additionally installed in an existing network Both air and electric systems can be

More information

28mm. Fieldbus System. EX260 Series. IP67 For units with D-sub connector, and when connected to S0700 manifolds, it is IP40. Drives up to 32 solenoids

28mm. Fieldbus System. EX260 Series. IP67 For units with D-sub connector, and when connected to S0700 manifolds, it is IP40. Drives up to 32 solenoids Fieldbus System EX60 Series (Output device for driving port solenoid valves) Compact 8mm Space-saving Installation RoHS IP67 For units with D-sub connector, and when connected to S0700 manifolds, it is

More information

The diagram below shows how cables and I/O modules are connected to form a plug-and-go system.

The diagram below shows how cables and I/O modules are connected to form a plug-and-go system. CompoBus/S IP67 I/O Modules Waterproof input and output blocks make wiring a snap and replacement of sensors or actuators a quick twist of a connector. These IP67 rated blocks are perfect for plug-and-go

More information

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs 1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector

More information

Contents. EX600 serial interface unit (PROFIBUS DP, DeviceNet, EtherNet/IP, EtherCAT)

Contents. EX600 serial interface unit (PROFIBUS DP, DeviceNet, EtherNet/IP, EtherCAT) 19 Fieldbus 160 Fieldbus Contents EX600 serial interface unit (PROFIBUS DP, DeviceNet, EtherNet/IP, EtherCAT) EX260 serial interface unit (DeviceNet, PROFIBUS DP, PROFINET, EtherCAT) EX20 serial interface

More information

Fieldbus System (For Input/Output)

Fieldbus System (For Input/Output) Fieldbus System (For Input/) Series RoHS Compatible Protocols New Unit type added Dual port SI Unit (EtherNet/IPTM) product Reduction in wiring time with SPEEDCON (Phoenix Contact). Just insert and make

More information

No.EX##-OMN0034. Fieldbus system CC-Link compatible SI unit PRODUCT NAME. EX600-SMJ# EX600-ED# MODEL/ Series

No.EX##-OMN0034. Fieldbus system CC-Link compatible SI unit PRODUCT NAME. EX600-SMJ# EX600-ED# MODEL/ Series Fieldbus system CC-Link compatible SI unit PRODUCT NAME EX600-SMJ# EX600-ED# MODEL/ Series Table of Contents Safety Instructions 2 System Outline 8 Definition and terminology 9 Assembly 11 Basic precautions

More information

EtherNet/IP TM SI unit

EtherNet/IP TM SI unit EX##-####### PRODUCT NAME EtherNet/IP TM SI unit MODEL / Series / Product Number UIUSP-SEN#-DUO02979 Contents Safety Instructions 2 How to Order 7 Summary of Product elements 8 Installation and Cabling

More information

Fieldbus system EtherCAT compatible SI unit

Fieldbus system EtherCAT compatible SI unit PRODUCT NAME Fieldbus system EtherCAT compatible SI unit MODEL / Series/ Product Number EX600-SEC# EX600-ED# Table of Contents Safety Instructions 2 System Outline 8 Definition and terminology 9 Assembly

More information

Fieldbus system Analog unit

Fieldbus system Analog unit PRODUCT NAME Fieldbus system Analog unit MODEL / Series / Product Number EX600-AXA EX600-AYA EX600-AMB Table of Contents Safety Instructions 3 System Outline 9 Assembly 10 Mounting and Installation 12

More information

No.EX##-OMN0030-A. Fieldbus system DeviceNet TM compatible SI unit PRODUCT NAME. EX600-SDN#A EX600-ED# MODEL/ Series

No.EX##-OMN0030-A. Fieldbus system DeviceNet TM compatible SI unit PRODUCT NAME. EX600-SDN#A EX600-ED# MODEL/ Series Fieldbus system DeviceNet TM compatible SI unit PRODUCT NAME EX600-SDN#A EX600-ED# MODEL/ Series Table of Contents Safety Instructions 3 System Outline 9 Definition and terminology 10 Assembly 12 Mounting

More information

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet) INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, points (DeviceNet) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined

More information

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536

More information

Communication Controller CC-Link/CPL Converter CMC10A

Communication Controller CC-Link/CPL Converter CMC10A No. CP SS 1766E Communication Controller CC-Link/CPL Converter CMC10A The communication controller CMC10A is a converter designed for the communication between Yamatake's digital indicating controller

More information

No.EX##-OMN0036. Fieldbus system Digital unit PRODUCT NAME. EX600-DX## EX600-DY## EX600-DM## MODEL/ Series

No.EX##-OMN0036. Fieldbus system Digital unit PRODUCT NAME. EX600-DX## EX600-DY## EX600-DM## MODEL/ Series Fieldbus system Digital unit PRODUCT NAME EX600-DX## EX600-DY## EX600-DM## MODEL/ Series Table of Contents Safety Instructions 3 System Outline 9 Assembly 10 Mounting and Installation 12 Installation 12

More information

Fieldbus system EtherNet/IP TM compatible SI Unit

Fieldbus system EtherNet/IP TM compatible SI Unit PRODUCT NAME Fieldbus system EtherNet/IP TM compatible SI Unit MODEL / Series / Product Number EX600-SEN3/4 EX600-ED# Table of Contents Safety Instructions 2 System Outline 8 Definition and terminology

More information

CJ Series EtherNet/IP TM Connection Guide. SMC Corporation Solenoid Valve (SI Unit EX600-SEN#) P657-E1-01

CJ Series EtherNet/IP TM Connection Guide. SMC Corporation Solenoid Valve (SI Unit EX600-SEN#) P657-E1-01 CJ Series EtherNet/IP TM Connection Guide SMC Corporation Solenoid Valve (SI Unit EX600-SEN#) P657-E1-01 About Intellectual Property Rights and Trademarks Microsoft product screen shots reprinted with

More information

EtherCAT compatible Slave Unit added to the Series. EtherCAT Compatible Serial Transmission Slave Unit W4G-OPP8 Series. CKD Corporation.

EtherCAT compatible Slave Unit added to the Series. EtherCAT Compatible Serial Transmission Slave Unit W4G-OPP8 Series. CKD Corporation. New product EtherCAT Compatible Serial Transmission Slave Unit W4G-OPP8 Series EtherCAT compatible Slave Unit added to the Series Overview Valve wiring is reduced through the support of high-speed EtherCAT

More information

Fieldbus system (DeviceNet compliant)

Fieldbus system (DeviceNet compliant) PRODUCT NAME Fieldbus system (DeviceNet compliant) MODEL / Series / Product Number EX510-GDN1 Series Table of Contents Safety Instructions 3 Model Indication and How to Order 8 Summary of Product Parts

More information

Reduced wiring system. PROFIBUS-DP Compatible GW unit. Operation Manual EX510-GPR1. URLhttp://www.smcworld.com

Reduced wiring system. PROFIBUS-DP Compatible GW unit. Operation Manual EX510-GPR1. URLhttp://www.smcworld.com Reduced wiring system PROFIBUS-DP Compatible GW unit Operation Manual EX510-GPR1 URLhttp://www.smcworld.com 1 Table of Contents Thank you for purchasing the SMC reduced wiring system EX510 series. Please

More information

M8/M12 Connector. PCA/EX9/EX500 Series. Reduction in wiring time. Conforming to IEC Fieldwireable Connectors

M8/M12 Connector. PCA/EX9/EX500 Series. Reduction in wiring time. Conforming to IEC Fieldwireable Connectors / Connector /EX9/EX00 Series Fieldwireable Connectors Reduction in wiring time The man-hours can be decreased because no exclusive tools (such as solder, crimped terminal) are required.also, the wire length

More information

Fieldbus system PROFIBUS DP compatible SI unit

Fieldbus system PROFIBUS DP compatible SI unit PRODUCT NAME Fieldbus system PROFIBUS DP compatible SI unit MODEL / Series / Product Number EX600-SPR#A EX600-ED# Table of Contents Safety Instructions 3 System Outline 9 Definition and terminology 10

More information

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: R2K-1 SEN TRONIC AG. R2K Series 1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission

More information

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range) Description The sensors provide excellent results even with difficult-to-detect objects, e.g. small or thin parts, wires or bright metals. A variety of types cover a wide range of individual requirements

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

One step ahead in performance and mounting ease

One step ahead in performance and mounting ease 95 Micro Photoelectric Amplifier Built-in PM-5 SERIES PM-45 SERIES PM-5 SERIES General terms and conditions... F- guide... P.9~ Related Information Glossary of terms / General precautions...p.1549~ / P.155~

More information

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes. 1123 PHOTO PHOTO PARTICUR Type Edge Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.1593~ guide... P.1021~ General precautions... P.1595 Conforming to FDA regulations

More information

Fieldbus system EtherNet/IP TM compatible SI unit

Fieldbus system EtherNet/IP TM compatible SI unit PRODUCT NAME Fieldbus system EtherNet/IP TM compatible SI unit MODEL / Series / Product Number EX600-SEN# EX600-ED# Table of Contents Safety Instructions 3 System Outline 9 Definition and terminology 10

More information

SI unit for EtherNet/IP TM EX250-SEN1

SI unit for EtherNet/IP TM EX250-SEN1 PRODUCT NAME SI unit for EtherNet/IP TM MODEL / Series / Product Number EX250-SEN1 Table of Contents Safety Instructions 2 Product Summary 7 Definition and terminology 8 Model Indication and How to Order

More information

Optimum sensing capability for LCD manufacturing

Optimum sensing capability for LCD manufacturing SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent

More information

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch ZSE3A(F)/E3A Series RoHS Can copy to up to 1 switches simultaneously. setting labor Minimizing ZSE3 E3 ZSE4 E4 The settings of the master sensor can

More information

No.EX##-OMN0028. Fieldbus system PROFIBUS DP compatible SI unit PRODUCT NAME. EX600-SPR#A EX600-ED# MODEL/ Series

No.EX##-OMN0028. Fieldbus system PROFIBUS DP compatible SI unit PRODUCT NAME. EX600-SPR#A EX600-ED# MODEL/ Series Fieldbus system PROFIBUS DP compatible SI unit PRODUCT NAME EX600-SPR#A EX600-ED# MODEL/ Series Table of Contents Safety Instructions 3 System Outline 9 Definition and terminology 10 Assembly 12 Mounting

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

Fieldbus system (SI unit compatible CompoNet)

Fieldbus system (SI unit compatible CompoNet) PRODUCT NAME Fieldbus system (SI unit compatible CompoNet) MODEL / Series / Product Number EX12#-SCM# Table of Contents Safety Instructions 2 Product Summary 7 Model Identification and How to Order 7 Names

More information

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block USER S MANUAL FX2N-64DNET DeviceNet Interface Block FX2N-64DNET DeviceNet Interface Block Foreword This manual contains text, diagrams and explanations which will guide the reader in the correct installation

More information

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual 8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual Version 1.1 Content Overview... 1 Introduction... 1 Features... 2 Technical Specifications... 3 Packing List... 5 Safety Precaution...

More information

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing Oil-resistive, Long-range with Metal Housing ES-C Water- and Oil-resistive with Metal Housing Used for Long-range Sensing Satisfies the water- and oil-resistive requirements and safe enough for use in

More information

No.EX##-OMN0032. Fieldbus system EtherNet/IP TM compatible SI unit PRODUCT NAME. EX600-SEN# EX600-ED# MODEL/ Series

No.EX##-OMN0032. Fieldbus system EtherNet/IP TM compatible SI unit PRODUCT NAME. EX600-SEN# EX600-ED# MODEL/ Series Fieldbus system EtherNet/IP TM compatible SI unit PRODUCT NAME EX600-SEN# EX600-ED# MODEL/ Series Table of Contents Safety Instructions 3 System Outline 9 Definition and terminology 10 Assembly 12 Mounting

More information

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4 OPERATION MANUAL E/P REGULATOR MODEL NAME ITV*0*0 *0*0-DE**** series Series For DeviceNet TM CONTENTS TM Contents Safety Instructions P1 P2 Precautions for Handling P3-4 Wiring and LED display P5-6 Mounting

More information

The importance of the static electric control is put on confirming the actual status.

The importance of the static electric control is put on confirming the actual status. Electrostatic Sensor IZD10/IZE11 Series Potential measurement: ±20 kv (detected at a 50 mm distance) ±0.4 kv (detected at a 25 mm distance) Detects the electrostatic potential and outputs in an analog

More information

SI unit for IO-Link device

SI unit for IO-Link device PRODUCT NAME SI unit for IO-Link device MODEL / Series / Product Number EX260-SIL1-X207 EX260-SIL1-X210 EX260-SIL3-X207 Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary

More information

Multi-Axis Step Motor Controller

Multi-Axis Step Motor Controller INFORMATION Multi-Axis Step Motor Controller RoHS VSpeed tuning control *1 (3 Axes: 4 Axes: ) V Linear/circular interpolation Axis 2 Linear interpolation 50 40 30 20 10 Origin 0 Current position Target

More information

EtherNet/IP TM Compatible Fieldbus System

EtherNet/IP TM Compatible Fieldbus System PRODUCT NAME EtherNet/IP TM Compatible Fieldbus System MODEL / Series / Product Number EX500-GEN2 EX500-S103 EX500-DXP# Table of Contents Safety Instructions 3 Product Overview 9 System construction 9

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter Series 0-PSE00 RoHS Remote Type Multi-Channel Digital Pressure Sensor Controller How to Order Clean series 0 PSE0 0 M Input/Output specifications 0 NPN 5 outputs + Auto shift input PNP 5 outputs + Auto

More information

RS232C/RS485 Data can be easily monitored by LAN

RS232C/RS485 Data can be easily monitored by LAN KS SIGNAL CVERTER (AKS) RSC/RS8 Data can be easily monitored by LAN KS SIGNAL CVERTER FEATURES The connectors are located on the front panel. Easy to connect Easy to operate Can be connected to the LAN

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Instruction Manual. Reduced wiring system EtherNet/IP Compatible SI Unit EX250-SEN1. URL

Instruction Manual. Reduced wiring system EtherNet/IP Compatible SI Unit EX250-SEN1. URL Reduced wiring system EtherNet/IP Compatible SI Unit Instruction Manual EX-SEN URL http:// www.smcworld.com Specifications are subject to change without prior notice and any obligation on the part of the

More information

Programless Controller (With Stroke Study) How to Order

Programless Controller (With Stroke Study) How to Order Specialized for Series LEM Programless Controller (With Stroke Study) Series LECP RoHS P LE C P N Controller Compatible motor Step motor (Servo/ VDC) Number of step data (Points) stroke end points/ intermediate

More information

SI unit for IO-Link device

SI unit for IO-Link device PRODUCT NAME SI unit for IO-Link device MODEL / Series / Product Number EX260-SIL1-X207 EX260-SIL1-X210 EX260-SIL3-X207 Table of Contents Safety Instructions 2 Model Numbers 8 Summary of Product 9 Summary

More information

BGS (at min. setting) BGS (at max. setting)

BGS (at min. setting) BGS (at max. setting) Compact Photoelectric Sensor with Built-in Amplifier EZ-LS CSM_EZ-LS_DS_E_7_ Distance-settable Sensor Unaffected by Workpiece Color and Background Distance-settable triangulation model unaffected by color.

More information

Contact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position)

Contact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position) D3D Miniature Door Switch Appliance industry standard plunger and lever actuator styles High contact reliability ensured using gold alloy crossbar contacts Drip/spill sealing in free position (plunger

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

No.EX##-OML0007. Fieldbus system DeviceNet TM compatible PRODUCT NAME. EX600-SDN* EX600 DX* EX600 DY* EX600 AX* MODEL/ Series

No.EX##-OML0007. Fieldbus system DeviceNet TM compatible PRODUCT NAME. EX600-SDN* EX600 DX* EX600 DY* EX600 AX* MODEL/ Series Fieldbus system DeviceNet TM compatible PRODUCT NAME EX600-SDN* EX600 DX* EX600 DY* EX600 AX* MODEL/ Series Table of Contents Safety Instructions 2 Product Outline 9 Assembly 11 Mounting and Installation

More information

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC Standard (thin shape) Inductive Proximity Sensor Thin shape for space saving surface mounting Direct side wall mounting for bracket-less installation Ordering Information DC 3-wire Models Installation

More information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information Chemical-resistant Proximity Sensor E2KQ-X CSM_E2KQ-X_DS_E_4_3 Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster Excellent resistance against chemicals and oil with fluororesincoated case.

More information

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.) Separate Construction with Cylindrical 16-dia. Body Miniature design of 28.5 mm, the smallest class in the industry. Detachable

More information

Classification Enclosure rating Input voltage Type of

Classification Enclosure rating Input voltage Type of Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.

More information

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

PSR-PS21. SIL coupling relay. Data sheet. 1 Description SIL coupling relay Data sheet 106253_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection) INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection) R7ML-DC16D MODEL R7ML-DC16D BEFORE USE... Thank you for choosing M-System. Before use, please

More information

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0. Built-in Amplifier Photoelectric Sensor E3V3 Easy-to-use, Low-cost Photoelectric Sensor Incorporating s that can be clearly seen from a distance. A series of models with an M8 metal junction connector

More information

Industrial Control Relays Relays and terminal module RS type

Industrial Control Relays Relays and terminal module RS type Relaysandterminal module Relays-and-terminal module RS, N A very compact, space-saving terminal module containing four or six relays with one NO contact. Features The RS series relays-and-terminal module

More information

Capacitive Proximity Sensor E2K-X

Capacitive Proximity Sensor E2K-X Sensing Supply voltage Output 90 to 0 VAC, 0/60 z to 30 VDC 00 ma, 8, 1 mm 00 ma NPN or PNP Capacitive Proximity Sensor Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact

More information

4 Axis Step Motor Controller

4 Axis Step Motor Controller INFORMATION 4 Axis Step Motor Controller (Parallel I/O) RoHS V 4 axis synchronous control V Linear/circular interpolation Linear interpolation 50 Circular interpolation 50 Target position Axis 0 Target

More information

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O Engineering Guideline pac-carriers Type 995 for Honeywell system Experion Series C I/O pac-carrier Type 995 Engineering Guideline/Honeywell 04..009 pac-carrier Type 995 Integration of conventional process

More information

Connections to a Wider Range of Slaves Ensured by Upgraded Models

Connections to a Wider Range of Slaves Ensured by Upgraded Models Connections to a Wider Range of Slaves Ensured by Upgraded Models Slave Products from other companies New product SMC CKD Koganei Products to be released soon Note: Solenoid valve for SI manifold use Solenoid

More information

CC-Link IE Field Basic compatible serial transmission slave unit W4G-T7 Series. CC-Link IE Field Basic compatible slave unit added to series!

CC-Link IE Field Basic compatible serial transmission slave unit W4G-T7 Series. CC-Link IE Field Basic compatible slave unit added to series! First in the industry CC-Link IE Field Basic compatible serial transmission slave unit W4G-T7 Series Serial Transmission unit W4G-T7 series CC-Link IE Field Basic compatible slave unit added to series!

More information

Photoelectric Sensors E3F2

Photoelectric Sensors E3F2 Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1 No. CP-SS-1865E Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1 Overview Network Instrumentation Modules make optimal distributed

More information

EtherCAT Remote I/O Terminal GX series

EtherCAT Remote I/O Terminal GX series EtherCAT Remote I/O Terminal GX series Digital I/O Terminal 2-tier Terminal Block Type Digital I/O Terminal 3-tier Terminal Block Type Digital I/O Terminal e-con Connector Type Analog I/O Terminal 2-tier

More information

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD To power supply Stepper Motor Driver LCD Electric Actuator Series LCC Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided

More information

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

No.:EX## OMH0025. Technical specification. Output block / Power block EX9-OET1 EX9-OET2 EX9-OEP1 EX9-OEP2 EX9-PE1

No.:EX## OMH0025. Technical specification. Output block / Power block EX9-OET1 EX9-OET2 EX9-OEP1 EX9-OEP2 EX9-PE1 No.:EX## OMH Technical specification Output / Power EX9-OET EX9-OET EX9-OEP EX9-OEP EX9-PE Table of Contents.Safety instructions.model -.Output for low wattage load -.Output for high wattage load -.Power

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

Communication & Networking

Communication & Networking MicroSmart Master Module Capable of Connecting 62 Slaves Compliance with Ver. 2.1 specifi cations Digital and analog slaves can be connected. Configuration and slave monitoring can be done using LED indicators

More information

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

PC Wiring System. e-con type is newly added! One-touch connection reduces wiring labor. Series PCW

PC Wiring System. e-con type is newly added! One-touch connection reduces wiring labor. Series PCW PC Wiring System Series PCW econ type is newly added! Onetouch connection reduces wiring labor. Branch unit offers commonality Branch unit separates each manufacturer s point Input/Output (I/O) into point

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

General-Purpose Photoelectric Sensor

General-Purpose Photoelectric Sensor General-Purpose Photoelectric Sensor Compact Limit Switch Style with Universal Supply FET output allows for solid state switching of AC or DC Universal AC/DC power supply Choose cable or connector types

More information

Link digital sensors directly to open networks

Link digital sensors directly to open networks 971 Unit for Open Network SERIES Related Information General terms and conditions... F-3 LS-500 / LS-400 / DPS-400... P.201~ / P.213~ / P.745~ FX-500 / FX-300...P.85~ / P.149~ General precautions... P.1595

More information

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks. 9 Relay I/O Block Reduces Wiring within the Control Panel and Reduces Installation Time 1 Compact 16-pt models: 182 W l 85 D l 68 H mm; 8-pt block width is 102 mm 1 Can be connected to the PLC with a connecting

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series 3 (For )/ 3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display Can be integrated with a vacuum unit, Series ZX Built-in

More information

Suitable for detecting transparent films or transparent bottles

Suitable for detecting transparent films or transparent bottles Ultrasonic Sensor Suitable for detecting transparent films or transparent bottles Reliable detection of transparent objects The sensor reliably detects transparent films or transparent objects. Only 16

More information