PRODUCTCATALOGUE. LV Switchgear Distribution Boards Consumer Units Circuit Protection Devices

Size: px
Start display at page:

Download "PRODUCTCATALOGUE. LV Switchgear Distribution Boards Consumer Units Circuit Protection Devices"

Transcription

1 PRODUCTCATALOGUE LV Switchgear Distribution Boards Consumer Units Circuit Protection Devices Installation Materials Division...the name behind the brands

2 Welcome to... Proteus Switchgear 2

3 YRS CELEBRATING 30 YEARS OF BRITISH MANUFACTURING ProteusIndustrial ProteusConsumer Introduction With over 30 years manufacturing experience, Proteus Switchgear continues to expand and broaden its portfolio of electrical products and services. From Power Distribution to LV Switchgear, Metalclad Consumer Units to Circuit Protection, our focus is to offer a complete solution for the domestic, commercial, retail and industrial market sectors. With two manufacturing facilities based in the heart of the UK, we are ideally placed to service over 800 distributors worldwide. Continual investment enables the company to remain in step with our customers expectations, maintain quality, develop new products and respond to market and regulatory requirements. The ongoing development of our manufacturing processes ensures Proteus Switchgear continually supply quality products for today's customer. FS

4 Content 400V Switchgear LV Switchboards...4 Custom Built LV Systems...5 Special MCCB Panelboards...6 Specials...7 MC Range MCCB Panelboards...8 Moulded Case Circuit Breakers...20 MCX 3-Phase Distribution Boards...24 CBX 3-Phase Distribution Boards...25 XL 3-Phase Distribution Boards...26 BX 3-Phase Distribution Boards...28 ABX 3-Phase Distribution Boards...32 AX Single Phase Distribution Boards...33 IP65 Power Distribution Boards Fuse Gear & Isolators...35 Changeover Switches...42 Busbar Chambers...44 ABS Enclosures...46 Contactors & Emergency Stops...47 Earth Bars...48 MCBs, RCBOs & RCDs...49 SPD - Surge Protection...52 MCB Boards with Surge Protection V Switchgear Metalclad Consumer Units...58 Insulated Consumer Units...66 Enclosures/Multi-Purpose Units...70 Meter Isolator Products...72 Switch Fuses/Fire Alarm Switches...73 Three Phase Consumer Units...74 MCBs, RCBOs & RCDs...49 Timers...76 Contactors & Isolators...77 Accessories...78 Specials...80 Mantel Units...81 Technical Information

5 Industrial Switchgear Division Proteus are committed to bringing our customers solutions for power distribution and energy efficiency, whilst focusing on the manufacture of switchgear products specifically designed to offer reliability from plant room to plug top. With many years of experience in Power & Distribution, we can help you make your energy use and distribution systems safer in order to protect your people, assets and business. Our comprehensive array of electrical distribution products, technologies and services, allows architects and facility owners a flexible approach to their electrical distribution needs. With considerable stock within our UK based factory and 800 distributors worldwide, we are ready and able to satisfy all of your power distribution needs. 3

6 LV Switchboards LV Switchboards Form 2, Form 3 and Form 4 level of segregation. Multi-function, analogue/digital tariff and non tariff metering. Restricted earth fault protection utilising Class X CTs providing protection of transformer LV windings. Cableways positioned to left or right hand of switchgear or with high/low level pre-connected terminals for front access applications. All switchgear has the option of 3 or 4 pole switching. General construction to BSEN &2 Specifiable options: Manual and automatic changeover systems. Fully integrated automatic PFC including multistage switching hand/off/auto selection, automatic control relays, contactors, fuse protection (25KVAr, 50KVAr stages as standard, other sizes available). Sealable supply authority CT chambers. Surge suppression. Modular design to customer requirements. Main incomer options up to 2500 amps (0)

7 Custom Built LV Systems PROTEUS With increasing emphasis on energy conservation, Proteus Switchgear offers the complete range of intrinsic energy management, varying from timeswitch and relay logic to electronic microprocessor control* of lighting, heating and ventilation and fire/security systems. To meet these changing requirements in retail, commercial and industrial applications, Proteus Switchgear manufactures custom-designed energy management panels, typically incorporating the following options: Main incoming isolation/protection up to 800 amps. 24 hour essential services distribution. Point of entry/exit key switch controlled services. Fire alarm interlocking. Signage control/extended hours manual override. Emergency lighting test/battery discharge facility. Energy Management Panels General construction to BSEN &2 Panels built to specification or in conjunction with our technical departments. Custom Built LV Systems *Microprocessor specification to be confirmed by client and system supplier, i.e. unit free issued to Proteus for inclusion within panel. 5

8 Custom Built MCCB Boards Special MCCB Panelboards General construction to BSEN &2 Option of lockable doors for all MCCBs and MCB housings. Segregated cableways to suit specific cable sizes and types. Width and depth to suit. Feeder MCCB busbar section accepts MCCBs rated up to 250 amps as standard. Larger rated outgoing MCCBs can be factory fitted to busbar systems (upto 800A). Distribution busbars up to 800 amps. Standard enclosures to IP3X. IP65 enclosures are also available. Options of main incomer as 3 or 4 pole switching. Options of MCB or multi-function distribution boards. Busbar ratings from 200A to 800A. Additional facilities that can be included in custom built panels: Changeover systems Sealable Supply Authority Chambers Tariff and non-tariff kwh metering Multi-function metering Surge suppression (0)

9 Specials Custom built assemblies to customer requirements PROTEUS Fitted Devices MCBs and RCBOs can be fitted and cabled to terminals and contactors / 3 or 5 pin sockets Surge Arrestors Type 2 surge arrestor cabled in parallel with supply. Din rail mounted. Cabling Assistance Devices can be cabled to panel mounted terminals to aid cabling Supply Authority C.T. Chamber Supply authority C.T. chamber with C.T. support plates. Built to specific supply authority requirements Specials 7

10 MC Range MCCB Panelboards MC Panel Boards Features & Benefits 250A, 400A and 800A busbar MCCB Panelboards. Outgoing MCCBs can be factory fitted on request. Available from 3 to 18 triple pole outgoing ways as standard. High fault level rating, 36kA Icc. Removable end plates for easy glanding and ease Factory fitted incoming MCCB/Isolator up to 800A (3 & 4pole). of installation. Standard board width 900mm allowing easy cabling. 3-Phase Panelboards fully compliant to BS EN & Modern design allows ultimate flexibility with SP & TP MCCBs which can be fitted in any position. Fully shrouded neutral terminal system with clear perspex covers. Door fitted over outgoing MCCBs as standard using high quality, steel pin hinges. Removable for ease of fitting. 5 Main earth termination 4 Outgoing MCCBs up to 250A TP and 200A SP. 5 Main earthing termination point onto high conductivity copper plate and robust bonding throughout (0)

11 MC Panel Boards Features & Benefits Construction gives type 2 and type 3 group mounted segregation to BS EN 61439:Pt1 & 2:2011. Constructed with 1.6mm thick steel with an epoxy paint finish to RAL7035. Other paint finishes available upon request. Key hole foot fixings for wall mounting. Lift off door hinges. PROTEUS MC Range MCCB Panelboards 9

12 MC Range MCCB Panelboards MCCB Panelboards - 250A Busbar 36kA Icc Available 3 to 18 triple pole outgoing ways. Factory fitted incoming MCCB/isolator up to 250A 3/4 pole. These boards utilise the busbar ability to accept 250A MCCBs by using one way as the incoming position when a 3 pole incomer is acceptable. MCP32/I200 Reduced height where space is at a premium. Any rating of MCCB up to 250A can be used as the incomer. The incoming device is fitted at the top right as standard to allow cable spreading room, this can be moved to any position. 200A MCCB Incomer or Switch Disconnector Fitted Boards No. of O/G Ways - 3 pole H (mm) W (mm) D (mm) 3 MCP32/I200 (S) MCP52/I200 (S) MCP72/I200 (S) MCP112/I200 (S) MCP152/I200 (S) MCP172/I200 (S) (S) - Add suffix S for Switch Disconnector Incomer Fitted Boards e.g. MCP32/I200S 200A MCCB Incomer Fitted Boards No. of O/G Ways - 4 pole H (mm) W (mm) D (mm) 4 MCP42/I200F MCP62/I200F MCP82/I200F MCP122/I200F MCP162/I200F MCP182/I200F MCP42/I200F MCP72/I A MCCB Incomer or Switch Disconnector Fitted Boards No. of O/G Ways - 3 pole H (mm) W (mm) D (mm) 3 MCP32/I250 (S) MCP52/I250 (S) MCP72/I250 (S) MCP112/I250 (S) MCP152/I250 (S) MCP172/I250 (S) (S) - Add suffix S for Switch Disconnector Incomer Fitted Boards e.g. MCP72/I250S 250A MCCB Incomer Fitted Boards No. of O/G Ways - 4 pole H (mm) W (mm) D (mm) 4 MCP42/I250F MCP62/I250F MCP82/I250F MCP122/I250F MCP162/I250F MCP182/I250F MCP62/I250F Outgoing switchgear supplied separately. Outgoing MCCB s upto 250A TP and 200A SP (0)

13 MCCB Panelboards - 250A Busbar 36kA Icc Range of side extension boxes, side meter boxes, bottom extension boxes and corner boxes to suit 250A range of MC panels. Bottom extension boxes are available in 200 or 300 mm height as standard. Side extension and meter boxes are available in left/ MCPEB32L MCPMB52R MCPBEB200 MCPCB34L Side Extension Box - 3 & 4 Pole Incomer (Left side) (Right side) H (mm) W (mm) D (mm) MCPEB32L MCPEB32R MCPEB52L MCPEB52R MCPEB72L MCPEB72R MCPEB112L MCPEB112R MCPEB152L MCPEB152R MCPEB172L MCPEB172R MCPEB42FL* MCPEB42FR* MCPEB62FL* MCPEB62FR* MCPEB82FL* MCPEB82FR* MCPEB122FL* MCPEB122FR* MCPEB162FL* MCPEB162FR* MCPEB182FL* MCPEB182FR* * - To suit four pole boards. No. of Meter Positions right hand and 3/4pole versions sized to suit all. 250A range MC panels Corner boxes available when using side and bottom boxes to give a clean look. Meters, SPD and EFR for meter boxes available on pages 12 and 13. Side Meter Extension Box - 3 & 4 Pole Incomer (Left side) (Right side) H (mm) W (mm) D (mm) 2 MCPMB32L MCPMB32R MCPMB52L MCPMB52R MCPMB72L MCPMB72R MCPMB112L MCPMB112R MCPMB152L MCPMB152R MCPMB172L MCPMB172R MCPMB42FL* MCPMB42FR* MCPMB62FL* MCPMB62FR* MCPMB82FL* MCPMB82FR* MCPMB122FL* MCPMB122FR* MCPMB162FL* MCPMB162FR* MCPMB182FL* MCPMB182FR* * - To suit four pole boards. Bottom Extension Box H (mm) W (mm) D (mm) MCPBEB MCPBEB Can also be fitted to top of panel if required. Corner Extension Box (Left side) (Right side) H (mm) W (mm) D (mm) MCPCB22L MCPCB22R MCPCB32L MCPCB32R MCPCB24L MCPCB24R MCPCB34L MCPCB34R MC Range MCCB Panelboards PROTEUS 11

14 MC Range MCCB Panelboards MCCB Panelboards - 400A Busbar 36kA Icc Available 4 to 18 triple pole outgoing ways. Factory fitted incoming MCCB/isolator up to 400A 3/4 pole. Ample cabling space for incoming cables. Space next to incomer for metering, earth leakage MCP44/I315 No. of O/G Ways 3 pole protection and surge protection to monitor and protect whole board. 315A MCCB Incomer Fitted Boards H (mm) W (mm) D (mm) 4 pole 4 MCP44/I315 MCP44/I315F MCP64/I315 MCP64/I315F MCP84/I315 MCP84/I315F MCP124/I315 MCP124/I315F MCP164/I315 MCP164/I315F MCP184/I315 MCP184/I315F MCP44/I400 MCP84/I400S 400A MCCB Incomer or Switch Disconnector Fitted Boards No. of H (mm) W (mm) D (mm) O/G Ways 3 pole 4 pole 4 MCP44/I400 (S) MCP44/I400F MCP64/I400 (S) MCP64/I400F MCP84/I400 (S) MCP84/I400F MCP124/I400 (S) MCP124/I400F MCP164/I400 (S) MCP164/I400F MCP184/I400 (S) MCP184/I400F (S) - Add suffix S for Switch Disconnector Incomer option e.g. MCP84/I400S. Triple pole only MCP124/I400 Outgoing switchgear supplied separately. Outgoing MCCB s upto 250A TP and 200A SP (0)

15 MCCB Panelboards - 400A Busbar 36kA Icc Range of side extension boxes, side metering available in left/right hand versions sized to suit all boxes, bottom extension boxes and corner boxes to 400A range MC panels. suit 400A range of MC panels. Corner boxes available when using side and bottom Bottom extension boxes are available in 200 or 300 extension boxes to give a clean look. mm heights as standard. Meters, SPD, EFR for meter boxes available on Side extension and meter extension boxes are pages 12 and 13. Side Extension Box (Left side) (Right side) H (mm) W (mm) D (mm) MCPEB44L MCPEB44R MCPEB64L MCPEB64R MCPEB84L MCPEB84R MCPEB124L MCPEB124R MCPEB164L MCPEB164R MCPEB184L MCPEB184R PROTEUS MCPEB64L No. of Meter Positions (Left side) Side Meter Extension Box H (mm) W (mm) D (mm) (Right side) 2 MCPMB44L MCPMB44R MCPMB64L MCPMB64R MCPMB84L MCPMB84R MCPMB124L MCPMB124R MCPMB164L MCPMB164R MCPMB184L MCPMB184R MCPMB124L MCPBEB200 MCPCB34L Bottom Extension Box H (mm) W (mm) D (mm) MCPBEB MCPBEB Can also be fitted to the top of the panel if required. Corner Extension Box (Left side) (Right side) H (mm) W (mm) D (mm) MCPCB22L MCPCB22R MCPCB32L MCPCB32R MCPCB24L MCPCB24R MCPCB34L MCPCB34R MC Range MCCB Panelboards 13

16 MC Range MCCB Panelboards MCCB Panelboards - 800A Busbar 36kA Icc Available 4 to 18 triple pole outgoing ways. Factory fitted incoming MCCB/isolator up to 800A 3/4 pole. Ample cabling space for incoming cables. Space next to incomer for metering, earth leakage MCP48/I500 No. of O/G Ways 3 pole protection and surge protection to monitor and protect whole board. 500A MCCB Incomer Fitted Boards H (mm) W (mm) D (mm) 4 pole 4 MCP48/I500 MCP48/I500F MCP68/I500 MCP68/I500F MCP88/I500 MCP88/I500F MCP128/I500 MCP128/I500F MCP168/I500 MCP168/I500F MCP188/I500 MCP188/I500F MCP48/I630S 630A MCCB Incomer or Switch Disconnector Fitted Boards No. of H (mm) W (mm) D (mm) O/G Ways 3 pole 4 pole 4 MCP48/I630 (S) MCP48/I630F MCP68/I630 (S) MCP68/I630F MCP88/I630 (S) MCP88/I630F MCP128/I630 (S) MCP128/I630F MCP168/I630 (S) MCP168/I630F MCP188/I630 (S) MCP188/I630F (S) - Add suffix S for Switch Disconnector Incomer option e.g. MCP88/I630S. Triple pole only MCP128/I800F 800A MCCB Incomer or Switch Disconnector Fitted Boards No. of H (mm) W (mm) D (mm) O/G Ways 3 pole 4 pole 4 MCP48/I800 (S) MCP48/I800F MCP68/I800 (S) MCP68/I800F MCP88/I800 (S) MCP88/I800F MCP128/I800 (S) MCP128/I800F MCP168/I800 (S) MCP168/I800F MCP188/I800 (S) MCP188/I800F (S) - Add suffix S for Switch Disconnector Incomer option e.g. MCP88/I800S. Triple pole only Outgoing switchgear supplied separately. Outgoing MCCB s upto 250A TP and 200A SP (0)

17 MCCB Panelboards - 800A Busbar 36kA Icc Range of side extension boxes, side metering available in left/right hand versions sized to suit all boxes, bottom extension boxes and corner boxes to 800A range MC panels. suit 800A range of MC panels. Corner boxes available when using side and bottom Bottom extension boxes are available in 200 or 300 extension boxes to give a clean look. mm heights as standard. Meters, SPD, EFR for meter boxes available on Side extension and meter extension boxes are Pages 12 and 13. Side Extension Box (Left side) (Right side) H (mm) W (mm) D (mm) MCPEB48L MCPEB48R MCPEB68L MCPEB68R MCPEB88L MCPEB88R MCPEB128L MCPEB128R MCPEB168L MCPEB168R MCPEB188L MCPEB188R PROTEUS MCPEB68L MCPMB128L MCPBEB200 MCPCB34L No. of Meter Positions (Left side) Side Meter Extension Box H (mm) W (mm) D (mm) (Right side) 2 MCPMB48L MCPMB48R MCPMB68L MCPMB68R MCPMB88L MCPMB88R MCPMB128L MCPMB128R MCPMB168L MCPMB168R MCPMB188L MCPMB188R Bottom Extension Box H (mm) W (mm) D (mm) MCPBEB MCPBEB Can also be fitted to the top of the panel if required. Corner Extension Box (Left side) (Right side) H (mm) W (mm) D (mm) MCPCB22L MCPCB22R MCPCB32L MCPCB32R MCPCB24L MCPCB24R MCPCB34L MCPCB34R MC Range MCCB Panelboards 15

18 MC Range MCCB Panelboards Metering Tariff and non tariff multifunction meters. Fitting into side meter boxes for outgoing devices or 250A incomers. Fitted next to incomer on 400A and 800A panels. Non-Tariff Multifunction Multimeters (1 & 3 Phase) Amperage (3 Ph) (1 Ph) 63A MCPMFM063T MCPMFM063S 100A MCPMFM100T MCPMFM100S 125A MCPMFM125T MCPMFM125S 160A MCPMFM160T MCPMFM160S 200A MCPMFM200T MCPMFM200S 250A MCPMFM250T - To be fitted in meter extension boxes to monitor outgoing / incoming circuits up to 250A. e.g.6 way panelboard c/w 400A TP MCCB incomer (MCP64/I400). Compatible meter extension boxes could be fitted on left (MCPMB64L) or right (MCPMB64R). Associated switchgear could be 5 x 100A TP MCCBs (MC100T) and 5 x Digital multimeters (MCPMFM100T). MCPMFM063T Meter box supplied separately. MCPMFM063TMID Amperage 315A 400A 500A 630A 800A (3 Ph) MCPMFM315T MCPMFM400T MCPMFM500T MCPMFM630T MCPMFM800T Fitted adjacent to main incomer to monitor total panelboard power usage. No meter extension box required. MID/Tariff Multimeters (1 & 3 Phase) Amperage (3 Ph) (1 Ph) 63A MCPMFM063TMID MCPMFM063SMID 100A MCPMFM100TMID MCPMFM100SMID 125A MCPMFM125TMID MCPMFM125SMID 160A MCPMFM160TMID MCPMFM160SMID 200A MCPMFM200TMID MCPMFM200SMID 250A MCPMFM250TMID - To be fitted in meter extension boxes to monitor outgoing / incoming circuits up to 250A. e.g.6 way panelboard c/w 400A TP MCCB incomer (MCP64/I400). Compatible meter extension boxes could be fitted on left (MCPMB64L) or right (MCPMB64R). Associated switchgear could be 5 x 125A TP MCCBs (MC125T) and 5 x kwh meters (MCPMFM125TMID). Amperage (3 Ph) 315A 400A 500A 630A 800A MCPMFM315TMID MCPMFM400TMID MCPMFM500TMID MCPMFM630TMID MCPMFM800TMID To be fitted adjacent to main incomer to monitor total panelboard power usage. No meter extension box required (0)

19 Accessories It is intended that the earth leakage units are under the supervision of instructed or skilled persons as defined by regulation (ii) of the 17th Edition Wiring Regulations. MCPEL100 Amperage 100A 125A 160A 200A 250A Earth Leakage Units MCPEL100 MCPEL125 MCPEL160 MCPEL200 MCPEL250 To be fitted in meter extension boxes to monitor outgoing / incoming circuits earth leakage up to 250A. e.g.6 way panelboard c/w 400A TP MCCB incomer (MCP64/I400). Compatible meter extension boxes could be fitted on left (MCPMB64L) or right (MCPMB64R). Associated switchgear could be 5 x 100A TP MCCBs (MC100T) and 5 x Earth Leakage Units (MCPEL100). Amperage 400A 630A Earth leakage relay has adjustable trip current and time settings. The MCCB is tripped via its integral shunt trip coil. The full breaking capacity of the MCCB is retained. MCPEL400 MCPEL630 Fitted adjacent to main incomer to monitor total panelboard earth leakage. No meter extension box required. PROTEUS MCST4P400 Shunt Trip Units Description Voltage Device Shunt trip for MCCB up to 250A MCST3P250* 220V pole Shunt trip for MCCB 315A-630A MCST3P V 3 pole Shunt trip for MCCB up to 800A MCST3P V 3 pole Shunt trip for MCCB up to 100A MCST4P V 4 pole Shunt trip for MCCB 315A-400A MCST4P400** 220V 4 pole Shunt trip for MCCB 500A-630A MCST4P V 4 pole Shunt trip for MCCB up to 800A MCST4P V 4 pole * - For MC250TLF use S/T MCST3P630. ** - For MC250FLF use MCST4P400 MCA3P250 - Auxilary contact for MC016T to MC250T. Wire in series with shunt trip MCST3P250. Surge Arrestors - 3 Phase + N (4 Pole) Amperage Earthing 315A MCPT12/TNS TNS/TNC-S >315A MCPT12/TNSIF TNS/TNC-S 315A MCPT12/TT TT >315A MCPT12/TTIF TT >125A MCPT2/TNSIF TNS/TNC-S >125A MCPT2/TTIF TT To be fitted adjacent to main incoming device for boards rated with incomer from 315A - 800A. For 200A - 250A incomer boards, a bottom extension box must be used, e.g. MCPBEB200 if unfused or MCPBEB300 if fused. TYPE 1: Protection against the effects of lightning. TYPE 2: Protection against the effects of man made surges on the mains supply system. MC Range MCCB Panelboards 17

20 MC Range MCCB Panelboards MCCB Enclosures, Pre Assembled Units It is intended that the earth leakage units are under the supervision of instructed or skilled persons as defined by regulation (ii) of the 17th Edition Wiring Regulations. MCENC1 Earth leakage relay has adjustable trip current and time settings. The MCCB is tripped via its integral shunt trip coil. The full breaking capacity of the MCCB is retained. Enclosures To Suit Individual MCCBs (3 & 4 Pole) Amperage H (mm) W (mm) D (mm) 16A - 100A MCENC A - 200A MCENC A - 630A MCENC A MCENC A - 100A MCENC1F* A - 200A MCENC2F* A - 630A MCENC6F* A MCENC8F* * - Four pole option. 3 pole units will accept 1 x SP or 1 x TP MCCB. 4 pole units will accept 1 x 4P MCCB only. When fitting a SP MCCB, 2 blanking modules (MCCBM1) will also need to be installed. 250A MCCB must be large frame size MCCB (MC250TLF, MC250FLF). Stand Alone Earth Leakage Units Amperage 3 Pole + N 4 Pole H (mm) W (mm) D (mm) MCEL200T 100A MCEL100T MCEL100F A MCEL125T MCEL125F A MCEL160T MCEL160F A MCEL200T MCEL200F A MCEL250T MCEL250F A MCEL315T MCEL315F A MCEL400T MCEL400F A MCEL500T MCEL500F A MCEL630T MCEL630F CT internal diameters of 70mm from 100A to 200A and 120mm for current ratings from 250A to 630A. IP3X Enclosed MCCBs Amperage 3 Pole 4 Pole H (mm) W (mm) D (mm) MCE100T 63A enclosed MCCB MCE063T MCE063F A enclosed MCCB MCE080T MCE080F A enclosed MCCB MCE100T MCE100F A enclosed MCCB MCE125T MCE125F A enclosed MCCB MCE160T MCE160F A enclosed MCCB MCE200T MCE200F A enclosed MCCB MCE250T MCE250F A enclosed MCCB MCE315T MCE315F A enclosed MCCB MCE400T MCE400F A enclosed MCCB MCE500T MCE500F A enclosed MCCB MCE630T MCE630F A enclosed MCCB MCE800T MCE800F (0)

21 General Arrangements Additional Accessories PROTEUS Description Padlocking device MCPD SP MCCB blank MCCBM1 Incomer door MCPID 120mm 2 lug connection kit for MC016T-MC250T MCLK120 MCCBM1 150mm 2 lug connection kit for MC016T-MC250T MCLK mm 2 lug connection kit for MC016T-MC250T MCLK185 MC063T-MC250T long terminal shield MCLTS M8 nut insert and bolt for MC016T-MC250T MCNUTM8 MCNUTM8 250A Busbar System E E N MCP52/I250 MC250T N 700mm MCPEB52L MCPMB52R 200mm 900mm 400mm MCPCB22L MCPBEB mm MCPCB24R MCPEB64L 200mm MCPCB32L MCPT12/ TNS1F MCPEL400 E N MCP64/I mm MCPBEB300 MC400T Core Bal. CT E N 300mm 800mm 700mm MCPMF M400T 400A and 800A Busbar Systems * MCPMB64R 400mm MCPCB34R * - Only up to 400A incomer. 950mm 500A - 800A. Depth 170mm/215mm over door. MC Range MCCB Panelboards 19

22 Moulded Case Circuit Breakers MCCB Features & Benefits The moulded case circuit breakers are housed in fibre reinforced thermoset polyester that combines ruggedness, high dielectric and mechanical strength. High quality silver alloy contacts (with elements of tungsten and graphite) ensure both high conductivity at point contact and minimal pitting during switching for a longer contact life. Positive contact indication is by means of the operating lever position. Moulded Case Circuit Breakers BS EN Full technical detail, markings and adjustable parameters clearly identified. Box clamp terminals for connection of cables upto 120mm 2 (upto MC250T). Fully shrouded terminals. Mid-trip position of MCCB dolly. Phase barriers supplied with lug connected MCCBs (0)

23 MCCB Features & Benefits PROTEUS Moulded Case Circuit Breakers 21

24 Moulded Case Circuit Breakers MCCB The moulded case circuit breakers are housed in fibre reinforced thermoset polyester that combines ruggedness, high dielectric and mechanical strength. High quality silver alloy contacts (with elements MC125S MC016T Current Rating (A) No. of Poles ka Rating (ka) of tungsten and graphite) ensure both high conductivity at point contact and minimal pitting during switching for a longer contact life. Positive contact indication is by means of the operating lever position. Thermal Release Magnetic Release Single Pole MCCBs Terminal Capacity (mm 2 ) 16 SP 36 F 500A 120 MC016S 20 SP 36 F 500A 120 MC020S 25 SP 36 F 500A 120 MC025S 32 SP 36 F 500A 120 MC032S 40 SP 36 F 500A 120 MC040S 50 SP 36 F 500A 120 MC050S 63 SP 36 F 500A 120 MC063S 80 SP 36 F 800A 120 MC080S 100 SP 36 F 1000A 120 MC100S 125 SP 36 F 1250A 120 MC125S 160 SP 36 F 1600A 120 MC160S 200 SP 36 F 2000A 120 MC200S Triple Pole MCCBs 16 TP 36 A (0.8-1xIn) 250A 120 MC016T 20 TP 36 A (0.8-1xIn) 250A 120 MC020T 25 TP 36 A (0.8-1xIn) 250A 120 MC025T 32 TP 36 A (0.8-1xIn) 320A 120 MC032T 40 TP 36 A (0.8-1xIn) 400A 120 MC040T 50 TP 36 A (0.8-1xIn) 500A 120 MC050T 63 TP 36 A (0.8-1xIn) 630A 120 MC063T 80 TP 36 A (0.8-1xIn) 800A 120 MC080T 100 TP 36 A (0.8-1xIn) 1000A 120 MC100T 125 TP 36 A (0.8-1xIn) 1250A 120 MC125T 160 TP 36 A (0.8-1xIn) 1600A 120 MC160T 200 TP 36 A (0.8-1xIn) A (5-10xIn) 120 MC200T 250 TP 36 A (0.8-1xIn) A (5-10xIn) 120 MC250T** ** - For panel boards only. MC100TMR Motor Rating KW (approx.) MCCB Amps ka Rating (ka) Thermal Release Motor Rated MCCBs Magnetic Terminal Release Capacity (mm 2 ) 30 63A x In 15xIn 120 MC063TMR 37 80A x In 15xIn 120 MC080TMR A x In 15xIn 120 MC100TMR A x In 15xIn 120 MC125TMR A x In 15xIn 120 MC160TMR A x In 10-15xIn 120 MC200TMR A x In 10-15xIn 120 MC250TMR (0)

25 MCCB MC250TLF MC800F MC250TNA Current Rating (A) No. of Poles ka Rating (ka) Thermal Release Large Frame Triple Pole MCCBs Magnetic Release Terminal Capacity (mm 2 ) 250 TP 36 A (0.8-1xIn) A (5-10xIn) Lugged(M12) MC250TLF 315 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC315T 400 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC400T 500 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC500T 630 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC630T 800 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC800T 1000 TP 70 A (0.4-1xIn) A (2-10xIn) Lugged MC1000T*** 1250 TP 70 A (0.4-1xIn) A (2-10xIn) Lugged MC1250T*** 1600 TP 70 A (0.4-1xIn) A (2-10xIn) Lugged MC1600T*** Large Frame TP MCCBs can not be fitted as an outgoing device. F - Fixed A - Adjustable LF - Large frame. MC250TLF must be used when using as an individual cable in, cable out MCCB device. *** - This MCCB does not fit in MCP panelboards. Current Rating (A) Current Rating (A) No. of Poles No. of Poles ka Rating (ka) ka* Rating (ka) Thermal Release Thermal Release Magnetic Release Magnetic Release Four Pole MCCBs Terminal Capacity (mm 2 ) 63 FP 36 A Tunnel-120mm 2 MC063FA 100 FP 36 A Tunnel-120mm 2 MC100FA 125 FP 36 A Tunnel-120mm 2 MC125FA 160 FP 36 A Tunnel-120mm 2 MC160FA 200 FP 36 A X Tunnel-120mm 2 MC200FA 250 FP 36 A X Tunnel-120mm 2 MC250FA 250 FP 50 A X Lugged(M12) MC250FALF 315 FP 50 A X Lugged(M12) MC315FA 400 FP 50 A X Lugged(M12) MC400FA 500 FP 50 A X Lugged(M12) MC500FA 630 FP 50 A X Lugged(M12) MC630FA 800 FP 36 F 800A A (8-10xIn) Lugged(M12) MC800F F - Fixed A - Adjustable LF - Large frame. MC250FALF must be used when using as an individual cable in, cable out MCCB device. 4 Pole MCCBs cannot be fitted as outgoing devices in MCP panelboards. Triple Pole Non-Auto MCCBs Terminal Capacity (mm 2 ) 200 TP Tunnel-120mm 2 MC200TNA 250 TP Tunnel-120mm 2 MC250TNA 400 TP Lugged(M12) MC400TNA 630 TP Lugged(M12) MC630TNA 800 TP Lugged(M12) MC800TNA F - Fixed A - Adjustable. MC250FLF must be used when using as an individual cable in, cable out MCCB device. *Non-Auto MCCBs should be protected by a Proteus MC..T/F MCCB of the same rating. Non-Auto MCCBs cannot be fitted as outgoing devices in MCP panelboards. Moulded Case Circuit Breakers PROTEUS 23

26 MCX 3-Phase Distribution Boards MCX 3-Phase Distribution Boards The MCX range combination board brings together the standard TP&N MCB distribution board with typical 17.5mm module MCBs with the opportunity to fit larger amperage MCCBs upto 160A. Accepts MCBs up to 63A and RCBOs up to 45A MCX22/I200 MCX22/I250 Incomer (Factory fitted) 200A MCB/MCCB Distribution Boards No. of O/G H (mm) W (mm) D (mm) Ways 200A TP Isolator 2W-63A, 2W-160A MCX22/I A TP Isolator 2W-63A, 4W-160A MCX24/I A TP Isolator 4W-63A, 2W-160A MCX42/I A TP Isolator 4W-63A, 4W-160A MCX44/I A TP Isolator 6W-63A, 2W-160A MCX62/I A TP Isolator 6W-63A, 4W-160A MCX64/I A TP Isolator 8W-63A, 2W-160A MCX82/I A TP Isolator 8W-63A, 4W-160A MCX84/I A TP Isolator 12W-63A, 2W-160A MCX122/I A TP Isolator 12W-63A, 4W-160A MCX124/I Outgoing switchgear supplied separately. Incomer (Factory fitted) (17.5mm wide module). Accepts MCCBs 16A to 160A Isolator incomer fitted as standard. Manufactured to BSEN Part 1 & A MCB/MCCB Distribution Boards No. of O/G H (mm) W (mm) D (mm) Ways 250A TP Isolator 2W-63A, 2W-160A MCX22/I A TP Isolator 2W-63A, 4W-160A MCX24/I A TP Isolator 4W-63A, 2W-160A MCX42/I A TP Isolator 4W-63A, 4W-160A MCX44/I A TP Isolator 6W-63A, 2W-160A MCX62/I A TP Isolator 6W-63A, 4W-160A MCX64/I A TP Isolator 8W-63A, 2W-160A MCX82/I A TP Isolator 8W-63A, 4W-160A MCX84/I A TP Isolator 12W-63A, 2W-160A MCX122/I A TP Isolator 12W-63A, 4W-160A MCX124/I Outgoing switchgear supplied separately. Please refer to page 22 for MCCB circuit protection devices Please refer to pages 49 & 50 for MCB & RCBO circuit protection devices (0)

27 CBX 3-Phase Distribution Boards The CBX range combination board brings together the standard TP&N MCB distribution board with typical 17.5mm module MCBs with the opportunity to fit larger amperage MCBs upto 125A rated. Accepts MCBs up to 63A and RCBOs up to 45A CBX22/I200 CBX24/I250 CB125T/C CBENCTP Incomer (Factory fitted) (17.5mm wide module). Accepts MCBs 80A to 125A (26.3mm wide module). Isolator incomer fitted as standard. Manufactured to BSEN Part 1 & A MCB Distribution Boards H (mm) W (mm) D (mm) 200A TP Isolator 2W-63A, 2W-125A CBX22/I A TP Isolator 2W-63A, 4W-125A CBX24/I A TP Isolator 4W-63A, 2W-125A CBX42/I A TP Isolator 4W-63A, 4W-125A CBX44/I A TP Isolator 6W-63A, 2W-125A CBX62/I A TP Isolator 6W-63A, 4W-125A CBX64/I A TP Isolator 8W-63A, 2W-125A CBX82/I A TP Isolator 8W-63A, 4W-125A CBX84/I A TP Isolator 12W-63A, 2W-125A CBX122/I A TP Isolator 12W-63A, 4W-125A CBX124/I Outgoing switchgear supplied separately. Incomer (Factory fitted) 250A MCB Distribution Boards H (mm) W (mm) D (mm) 250A TP Isolator 2W-63A, 2W-125A CBX22/I A TP Isolator 2W-63A, 4W-125A CBX24/I A TP Isolator 4W-63A, 2W-125A CBX42/I A TP Isolator 4W-63A, 4W-125A CBX44/I A TP Isolator 6W-63A, 2W-125A CBX62/I A TP Isolator 6W-63A, 4W-125A CBX64/I A TP Isolator 8W-63A, 2W-125A CBX82/I A TP Isolator 8W-63A, 4W-125A CBX84/I A TP Isolator 12W-63A, 2W-125A CBX122/I A TP Isolator 12W-63A, 4W-125A CBX124/I Outgoing switchgear supplied separately. Description 80A SP type C MCB 80A TP type C MCB 100A SP type C MCB 100A TP type C MCB 125A SP type C MCB 125A TP type C MCB No. of O/G Ways No. of O/G Ways CB080S/C CB080T/C CB100S/C CB100T/C CB125S/C CB125T/C Type C MCB Enclosures Description H (mm) W (mm) D (mm) IP31 steel enclosures to SP CBENCSP IP31 steel enclosures to TP CBENCTP Please refer to page 22 for MCCB and pages 49 & 50 for MCB & RCBO circuit protection devices CBX 3-Phase Distribution Boards PROTEUS 25

28 XL 3-Phase Distribution Boards XL 3-Phase Distribution Boards 4 to 24 triple pole outgoing ways. Accepts MCBs from 2A to 63A and RCBOs from 6A to 45A (17.5mm wide module). Key lock available for door (XLKL). XL8S125 XL4S2 Incomer (Factory fitted) Dual Earth and Neutral terminal bars. Removable gland plates top & bottom. Manufactured to BSEN Part A Isolator Incomer Distribution Boards No. of O/G Ways H (mm) W (mm) D (mm) 125A TP Isolator 4 XL4S A TP Isolator 6 XL6S A TP Isolator 8 XL8S A TP Isolator 12 XL12S A TP Isolator 16 XL16S A TP Isolator 20 XL20S A TP Isolator 24 XL24S A Isolator Incomer Distribution Boards 200A TP Isolator 4 XL4S A TP Isolator 6 XL6S A TP Isolator 8 XL8S A TP Isolator 12 XL12S A TP Isolator 16 XL16S A TP Isolator 20 XL20S A TP Isolator 24 XL24S XL84SL Incomer (Factory fitted) Three Phase Split Load Distribution Boards No. of TP Way (isolator) No. of TP Ways (RCD) Cat. No. H (mm) W (mm) D (mm) 100A TP Isolator 4 6 XL46SL A TP Isolator 4 8 XL48SL A TP Isolator 6 4 XL64SL A TP Isolator 6 6 XL66SL A TP Isolator 8 4 XL84SL Fitted with a 100A 4pole 30mA RCD as standard. Xl Range Key Lock Description W (mm) D (mm) Key lock for XL range boards XLKL - - XLKL (0)

29 XL 3-Phase Distribution Boards The XL range of kwh metered boards and split load kwh metered boards, which can be used to meter lighting and power, have over 100% more cabling space than the XL8S1MD standard equivalent three phase board. kwh meters are factory fitted to monitor the number of ways chosen to suit the application. Metered Distribution Boards c/w Meter Description kwh H (mm) W (mm) D (mm) Meter 4 way TP&N MCB Board Analogue XL4S1MA way TP&N MCB Board Digital XL4S1MD way TP&N MCB Board Analogue XL6S1MA way TP&N MCB Board Digital XL6S1MD way TP&N MCB Board Analogue XL8S1MA way TP&N MCB Board Digital XL8S1MD way TP&N MCB Board Analogue XL12S1MA way TP&N MCB Board Digital XL12S1MD way TP&N MCB Board Analogue XL16S1MA way TP&N MCB Board Digital XL16S1MD All above units are supplied complete with a 100A 4pole incoming isolator as standard. PROTEUS XL68MD KWH2D TP meter Ways (lighting) Split Load Metered Distribution Boards TP meter kwh H (mm) W (mm) D (mm) Ways Meter (power) 4 6 Analogue XL46MA Digital XL46MD Analogue XL68MA Digital XL68MD Analogue XL812MA Digital XL812MD Additional split load configuration available on request. Split Load Metered Board Incoming Isolator Kits Description H (mm) W (mm) D (mm) 125A 4 pole isolator incoming kit XLI A 4 pole isolator incoming kit XLI Each individual XL distribution board unit with meter fitted must not exceed 100A full load current per phase. Select isolator incoming kit to satisfy the total load current demand. Outgoing switchgear supplied separately. Description kwh Meter Meters & Enclosures H (mm) W (mm) D (mm) 100A DP direct connect meter Analogue KWH2A A DP direct connect meter Digital KWH2D A 4P direct connect meter Analogue KWH4A A 4P direct connect meter Digital KWH4D A DP meter enclosure only - KWH2E A 4P meter enclosure only - KWH4E XL 3-Phase Distribution Boards 27

30 BX 3-Phase Distribution Boards BX 3-Phase Distribution Boards Available in 4, 6, 8, 12, 16, 20 to 24 triple pole outgoing ways. Wide selection of factory fitted incoming devices to choose from to meet the demands of modern installations. BX8S125 Incomer (Factory fitted) Accepts MCBs from 2A to 63A and RCBOs from 6A to 45A (17.5mm wide module). Dual Earth and Neutral terminal bars. Manufactured to BSEN parts 1 & 3. Removable gland plates, top and bottom. 125A Isolator Incomer Distribution Boards No. of O/G H (mm) W (mm) D (mm) TP Ways (Solid door) 125A TP Isolator 4 BX4S A TP Isolator 6 BX6S A TP Isolator 8 BX8S A TP Isolator 12 BX12S A TP Isolator 16 BX16S A TP Isolator 20 BX20S A TP Isolator 24 BX24S Incomer (Factory fitted) 200A Isolator Incomer Distribution Boards No. of O/G H (mm) W (mm) D (mm) TP Ways (Solid door) 200A TP Isolator 4 BX4S A TP Isolator 6 BX6S A TP Isolator 8 BX8S A TP Isolator 12 BX12S A TP Isolator 16 BX16S A TP Isolator 20 BX20S A TP Isolator 24 BX24S BX12S2 Incomer (Factory fitted) 250A Isolator Incomer Distribution Boards No. of O/G TP Ways (Solid door) H (mm) W (mm) D (mm) 250A TP Isolator 8 BX8S A TP Isolator 12 BX12S A TP Isolator 16 BX16S A TP Isolator 20 BX20S A TP Isolator 24 BX24S BX8S250 BX boards supplied with a solid door as standard and can be ordered with a clear door fitted by adding /CD to the part code (For example: BX6S1/CD) (0)

31 BX 3-Phase Distribution Boards BX6P30 63A Type A 4 Pole 30mA RCD Incomer Distribution Boards Incomer No. of O/G H (mm) W (mm) D (mm) (Factory fitted) TP Ways (Solid door) 63A 4P 30mA RCD 4 BX4P A 4P 30mA RCD 6 BX6P A 4P 30mA RCD 8 BX8P A 4P 30mA RCD 12 BX12P A 4P 30mA RCD 16 BX16P A 4P 30mA RCD 20 BX20P A 4P 30mA RCD 24 BX24P PROTEUS BX6Q30 80A Type A 4 Pole 30mA RCD Incomer Distribution Boards Incomer No. of O/G H (mm) W (mm) D (mm) (Factory fitted) TP Ways (Solid door) 80A 4P 30mA RCD 4 BX4Q A 4P 30mA RCD 6 BX6Q A 4P 30mA RCD 8 BX8Q A 4P 30mA RCD 12 BX12Q A 4P 30mA RCD 16 BX16Q A 4P 30mA RCD 20 BX20Q A 4P 30mA RCD 24 BX24Q Outgoing switchgear supplied separately. BXM14 BX Multi Purpose Units (Solid door) H (mm) W (mm) D (mm) BXM BXM BX boards supplied with a solid door as standard and can be ordered with a clear door fitted by adding /CD to the part code (For example: BX6S1/CD). BX 3-Phase Distribution Boards 29

32 BX 3-Phase Distribution Boards BX 3-Phase Distribution Boards BX4R30 BX6R100 BX6R A Type A 4 Pole 30mA RCD Incomer Distribution Boards H (mm) W (mm) D (mm) Incomer (Factory fitted) No. of O/G TP Ways (Solid door) 100A 4P 30mA RCD 4 BX4R A 4P 30mA RCD 6 BX6R A 4P 30mA RCD 8 BX8R A 4P 30mA RCD 12 BX12R A 4P 30mA RCD 16 BX16R A 4P 30mA RCD 20 BX20R A 4P 30mA RCD 24 BX24R A Type A 4 Pole 100mA RCD Incomer Distribution Boards Incomer No. of O/G H (mm) W (mm) D (mm) (Factory fitted) TP Ways (Solid door) 100A 4P 100mA RCD 4 BX4R A 4P 100mA RCD 6 BX6R A 4P 100mA RCD 8 BX8R A 4P 100mA RCD 12 BX12R A 4P 100mA RCD 16 BX16R A 4P 100mA RCD 20 BX20R A 4P 100mA RCD 24 BX24R A 100mA boards available with Type S RCD on request. 100A Type A 4 Pole 300mA RCD Incomer Distribution Boards Incomer No. of O/G H (mm) W (mm) D (mm) (Factory fitted) TP Ways (Solid door) 100A 4P 300mA RCD 4 BX4R A 4P 300mA RCD 6 BX6R A 4P 300mA RCD 8 BX8R A 4P 300mA RCD 12 BX12R A 4P 300mA RCD 16 BX16R A 4P 300mA RCD 20 BX20R A 4P 300mA RCD 24 BX24R A 300mA boards available with Type S RCD on request. Outgoing switchgear supplied separately. BXSB2 BX Accessories Description (Solid door) H (mm) W (mm) D (mm) Spreader box BXSB Spreader box BXSB /125A Single phase conv kit BXSCK A Single phase conv kit BXSCK Key lock for door XLKL BX boards supplied with a solid door as standard and can be ordered with a clear door fitted by adding /CD to the part code (For example: BX6S1/CD) (0)

33 Case Study HALFORDS Special Distribution Boards Halfords were previously purchasing pre-assembled, standard switch boards from an alternative overseas manufacturer, the design and lead time of which was becoming an issue and Halfords realised they required a more bespoke, future proof solution. Following contact with Proteus Industrial Switchgear of Telford a site visit to an existing store was arranged where further design discussions were held with the installation electricians. The discussions resulted in the design of a distribution panel incorporating multiple mcb boards, contactors, time switches and emergency lighting test equipment which were all designed to meet their future requirements An initial trial installation was successfully completed at the new Halfords store in Beckton. Bruce Birkmyre, Store Development Manager said, with Proteus being a UK based manufacturer it was easy to discuss our requirements and make any changes as the design progressed. The end result was a more cost effective panel board with reduced supply and site installation time.

34 ABX 3-Phase Distribution Boards ABX Boards Busbars are 80A max with 100A intermittent rating and are one piece construction. Cleanline overall hinged door (key operated lockable door optional). Accepts RCBOs and MCBs, 17.5mm wide module. ABX4S1 Incomer (Factory fitted) Isolators can be locked in ON and OFF position (using DL1 locking device). Robust IP3X steel construction. ABX Manufactured to BSEN61439 parts 1 & 3. No. of O/G TP Ways 3-Phase ABX Board - Horizontal H (mm) W (mm) D (mm) (Solid door) 100A 4P Isolator 2 ABX2S A 4P Isolator 4 ABX4S A 4P Isolator 6 ABX6S A 4P Isolator 8 ABX8S A 4P Isolator 12 ABX12S Incomer (Factory fitted) No. of O/G TP Ways 3-Phase ABX Board - Vertical H (mm) W (mm) D (mm) (Solid door) 100A 4P Isolator 2 ABX2S1V A 4P Isolator 4 ABX4S1V A 4P Isolator 6 ABX6S1V A 4P Isolator 8 ABX8S1V A 4P Isolator 12 ABX12S1V Outgoing switchgear ordered separately. ABX4S1V ABX2R30 No. of O/G TP Ways 100A 30mA RCD Incomer Horizontal ABX Type A RCD Boards 100A 100mA RCD Incomer 100A 300mA RCD Incomer H (mm) W (mm) D (mm) 2 ABX2R30 ABX2R100 ABX2R ABX4R30 ABX4R100 ABX4R ABX6R30 ABX6R100 ABX6R ABX8R30 ABX8R100 ABX8R ABX12R30 ABX12R100 ABX12R ABX4R300V No. of O/G TP Ways 100A 30mA RCD Incomer Vertical ABX Type A RCD Boards 100A 100mA RCD Incomer 100A 300mA RCD Incomer H (mm) W (mm) D (mm) 2 ABX2R30V ABX2R100V ABX2R300V ABX4R30V ABX4R100V ABX4R300V ABX6R30V ABX6R100V ABX6R300V ABX8R30V ABX8R100V ABX8R300V ABX12R30V ABX12R100V ABX12R300V (0)

35 AX Boards Busbars are 80A max with 100A intermittent rating and are one piece construction. Cleanline overall hinged door (key operated lockable door optional). Accepts RCBOs and MCBs, 17.5mm wide module. AX4 Incomer (Factory fitted) Isolator can be locked in ON or OFF position (using DL1 locking device). Robust IP3X steel construction. AX Manufactured to BSEN61439 parts 1 & 3. AX SP&N Type A Distribution Boards No. of O/G H (mm) W (mm) D (mm) SP Ways (Solid door) 100A DP Isolator 4 AX A DP Isolator 6 AX A DP Isolator 8 AX A DP Isolator 12 AX A DP Isolator 16 AX A DP Isolator 20 AX A DP Isolator 26 AX PROTEUS AX12MA Incomer (Factory fitted) AX SPN MCB Metered Distribution Boards No. of O/G H (mm) W (mm) D (mm) SP Ways (Solid door) 100A DP Isolator 4 AX4MA A DP Isolator 4 AX4MD A DP Isolator 8 AX8MA A DP Isolator 8 AX8MD A DP Isolator 12 AX12MA A DP Isolator 12 AX12MD All the above metered units are supplied complete with 100A 2 pole Isolators as standard and manufactured to BSEN Add suffix /CD for the clear door option. AX Single Phase Distribution Boards 33

36 IP65 Power Distribution Boards IP65 Power Distribution Boards All boards will accept RCBOs and MCBs 17.5mm wide modules. Isolators can be locked in ON and OFF position (using DL1 locking device). Manufactured to BSEN61439 parts 1 & 3. PDU4SS Incomer (Factory fitted) 125A TP Isolator - Steel Enclosure No. of O/G H (mm) W (mm) D (mm) TP ways (Solid door) 125A TP isolator 4 PDU4SS A TP isolator 6 PDU6SS A TP isolator 8 PDU8SS A TP isolator 12 PDU12SS A TP isolator 16 PDU16SS Incomer (Factory fitted) 200A TP Isolator - Steel Enclosure No. of O/G H (mm) W (mm) D (mm) TP Ways (Solid door) 200A TP isolator 4 PDU4S2S A TP isolator 6 PDU6S2S A TP isolator 8 PDU8S2S A TP isolator 12 PDU12S2S A TP isolator 16 PDU16S2S PDU6S2S Incomer (Factory fitted) 125A TP Isolator - GRP Enclosure No. of O/G H (mm) W (mm) D (mm) TP Ways (Solid door) 125A TP isolator 4 PDU4S A TP isolator 6 PDU6S A TP isolator 8 PDU8S A TP isolator 12 PDU12S A TP isolator 16 PDU16S PDU4S Incomer (Factory fitted) 200A TP Isolator - GRP Enclosure No. of O/G H (mm) W (mm) D (mm) TP Ways (Solid door) 200A TP isolator 4 PDU4S A TP isolator 6 PDU6S A TP isolator 8 PDU8S pole Type A RCD incomer options available on request factory fitted. Key locks for GRP Power Distribution Boards also available - GRPKL. Key locks for Steel Power Distribution Boards also available - STLKL. PDU4S (0)

37 IP65 Switch Disconnector Fuses Current Rating A AC21/AC23 No. of Poles Fused Switches - Steel Enclosed H (mm) W (mm) D1 (mm) D2 (mm) 63 3P + N WFS63/IP65SS P + N WFS100/IP65SS P + N WFS125/IP65SS P + N WFS160/IP65SS P + N WFS200/IP65SS PROTEUS WFS100/IP65 Current Rating A AC21/AC23 No. of Poles Fused Switches - GRP Enclosed H (mm) W (mm) D1 (mm) D2 (mm) 63 3P + N WFS63/IP P + N WFS100/IP P + N WFS125/IP P + N WFS160/IP P + N WFS200/IP Current Rating A AC21/AC23 Switch Disconnector Fuses - Steel Enclosed No. of Poles H (mm) W (mm) D1 (mm) D2 (mm) 20/11 3P + N WSF20/IP65SS /18 3P + N WSF32/IP65SS /35 3P + N WSF63/IP65SS WSF63/IP65SS 100/70 3P + N WSF100/IP65SS W H D1 D2 Current Rating A AC21/AC23 Switch Disconnector Fuses - GRP Enclosed No. of Poles H (mm) W (mm) D1 (mm) D2 (mm) 20/11 3P + N WSF20/IP /18 3P + N WSF32/IP /35 3P + N WSF63/IP /70 3P + N WSF100/IP Additional ratings available upon request. Manufactured to BSEN Fuse Gear & Isolators 35

38 Fuse Gear & Isolators Switch Disconnector Fuse Switch mechanism rated at 65kA when fitted with appropriate BS88 fuses. Heavy duty interlocking handle. Fully rated BS88 fuses fitted. 4 pole configuration available on request. Built-in cable box suitable for most applications. Manufactured to BSEN60947 parts 1 & 3. U200FS Current Rating A - AC23 CSA Max mm 2 Bolt Size (metric) Power Rating at 400V (kw) Proteus BS88 pt2 Fuse fitted H (mm) W (mm) D1 (mm) General Duty 63 95* M8 33 PBD U63FS * M8 55 PCD U100FS * M8 59 PDD U125FS * M8 75 PDD U160FS /185** M PDD U200FS /185** M PED U250FS ** M PED U315FS /240# M PED U400FS M PFF U500FS M PFF 630FS M PGF 800FS*** * - when using 95mm 2 cable it is recommended that the UCB1 is fitted. ** - when using 185mm 2 cable it is recommended that the UCB2 is fitted. # - when using 240mm 2 cable it is recommended that the UCB4 is fitted. *** - Floor standing unit. H D2 (mm) W D1 D (0)

39 Switch Disconnector PROTEUS U200S Current Rating A - AC23 H CSA Max mm 2 Bolt Size (metric) Power Rating at 400V (kw) H (mm) W (mm) D1 (mm) General Duty 63 95* M8 33 U63S * M8 55 U100S * M8 59 U125S * M8 75 U160S /185** M U200S /185** M U250S ** M U315S /240# M U400S M U500S M U630S D2 (mm) * - when using 95mm 2 cable it is recommended that the UCB1 is fitted. ** - when using 185mm 2 cable it is recommended that the UCB2 is fitted. # - when using 240mm 2 cable it is recommended that the UCB4 is fitted. W D1 D2 UCB2 Accessories Description H (mm) W (mm) D (mm) UCB Cable spreader box to suit up to U160FS/ U160S Cable spreader box to suit U200FS/U200S upto U315FS/U315S UCB Fuse Gear & Isolators Cable spreader box to suit U400FS/U400S UCB Fuse barrier for U250FS/S - U400FS/S UFB Fuse barrier for U063FS/S - U160FS/S UFB Handle for UFS/S UFH Shaft for UFS/S UFS

40 Fuse Gear & Isolators Telford Switchgear Range Epoxy powder coat finish. Fully insulated rotary operating handle. Robust, heavy duty steel enclosure. Padlockable in off position for security. Folded construction for extra rigidity. Screened or finger protected terminals. Flush fitting door. Manufactured to BSEN60947 parts 1 & 3. Door removable for ease of installation. TS100T Current Rating A AC21A/ AC22A Current Rating A AC23A Power at 400v (kw) AC23A Max. Stranded Cable CSA mm 2 Cable Termination Type Switch Disconnector H (mm) W (mm) D1 (mm) Tunnel TS20T Tunnel TS32T Tunnel TS63T Tunnel TS100T M8 Lug TS125T M8 Lug TS160T M8 Lug TS200T D2 (mm) H W D1 D2 TSF20T Current Rating A AC21A/ AC22A Current Rating A AC23A Power at 400v (kw) Max. Stranded Cable CSA mm 2 Proteus BS88 pt.2 Fuse Cable Termination Type Switch Disconnector Fuses Cat. H W D1 D2 No. (mm) (mm) (mm) (mm) PNITD Tunnel TSF20T PNITD Tunnel TSF32T PBAO Tunnel TSF63T PCEO M8 Lug TSF100T PDD M8 Lug TSF160T (0)

41 Euro Switchgear Range Fully insulated high visibility rotary operating handle. Padlockable in off position for security. Finger protected cable terminations. Epoxy powder coat finish. Robust, heavy duty steel enclosure. E20TN Folded steel construction for extra rigidity. Flush fitting door. Door removable for ease of installation. Manufactured to BSEN60947 parts 1 & 3. Switch Disconnectors Current Current Power Max. Cable Rating A AC21A/ AC22A Rating A AC23A at 400v (kw) AC23A Stranded Cable CSA mm 2 Termination Type Tunnel E20TN Tunnel E32TN Tunnel E63TN Tunnel E100TN Tunnel E160TN Tunnel E200TN PROTEUS Current Rating A AC21A/ AC22A No. of Poles Current Rating A AC23A Power at 400v (kw) AC23A Max. Stranded Cable CSA mm 2 Switch Disconnector Fuses Proteus Fuse to BS88 pt.2&6/ Spare Fuse Unit Cat. No P+N PNSD/TDH2 Part [6] EF20TN 20 1 P+N PNSD/TDH2 Part [6] EF20S EF20TN 20 2 P+N PNSD/TDH2 Part [6] EF20D 32 3 P+N PNSD/TDH3 Part [6] EF32TN 32 1 P+N PNSD/TDH3 Part [6] EF32S 32 2 P+N PNSD/TDH3 Part [6] EF32D 63 3 P+N TIS/TDH6 Part [2] EF63TN 63 1 P+N TIS/TDH6 Part [2] EF63S 63 2 P+N TIS/TDH6 Part [2] EF63D P+N TCP/TDH10 Part [2] EF100TN P+N TCP/TDH10 Part [2] EF100S W H D P+N TCP/TDH10 Part [2] EF100D Key features - as above plus, Fully rated fuses fitted. Cable Termination Type - Tunnel. TIS and TCP are Bolt in fuses to BS88 pt2. Accessory - MN10 is a screw fixed add-on switched 4th pole for 63/100A units D2 Sizes Product H (mm) W (mm) D1 (mm) D2 (mm) E20TN, E32TN E63TN, E100TN E160TN, E200TN EF20TN, EF32TN, EF20S, EF32S, EF20D, EF32D EF63TN, EF63S, EF63D EF100S, EF100D, EF100TN Fuse Gear & Isolators 39

42 Fuse Gear & Isolators Madeley Switchgear Range Manufactured to BSEN Parts 1 & 3. IP65 polycarbonate enclosure. Cable knockouts provided. Padlockable operating handle for security. M32T M254 M206 Current Rating A AC21A Power at 400v (kw) AC23A 3 Pole IP65 Rotary Isolator Power at No. of Max. 400v (kw) Poles Cable AC M20T M25T M32T M63T M100T M160T M200T Current Rating A AC21A Power at 400v (kw) AC23A 4 Pole IP65 Rotary Isolator Power at No. of Max. 400v (kw) Poles Cable AC M M M M M M M2004 Current Rating A AC21A Finger protected cable terminations. Earth & Neutral terminals fitted. Customer fitted auxiliary contacts (6 amp rated 1-N/O, 1-N/C) available on 3 pole units. Power at 400v (kw) AC23A 6 Pole IP65 Rotary Isolator Power at No. of Max. 400v (kw) Poles Cable AC x 2.5 M M M * 6 M * 35 M6362 * - Fitted with 2 auxiliary contacts. Sizes Product H (mm) W (mm) D1 (mm) D2 (mm) M20T, M25T, M32T, M204, M254, M M63T, M H M100T, M M160T, M M200T, M W D1 D2 M M326, M M636, M (0)

43 PROTEUS Case Study DRAYTON MANOR THEME PARK - THOMAS LAND PRO2000 LV Switchboard Proteus Switchgear PRO2000 LV switchboard was designed to tap off from an 11kV ring to supply the vast majority of the Thomas Land s electrical needs. The timescale for the project was tight from the onset and as quoted by the contractor only Proteus Switchgear offered to meet the challenge. The goods were specified, quoted, designed and supplied within 8 weeks. Keeping the progress of the project on schedule and supporting the contractor along the way with respect to technical support and advice were key to customer satisfaction. Proteus Switchgear were also noted for their excellent co-operation and team work when it came to accommodating a significant mid-project modification to the switchboard involving the upgrading of an outgoing switch fuse from 100A to 250A. With the assistance of Proteus staff the work involved in changeover was completed in less than 1 hour The contractor claims the high profile of the installation and overall successful completion and handover of the project has also increased the profile of his company and led to further job opportunities for his team with work on this scale. PX Switch 3-Phase Disconnector Distribution Fuse Boards Units 41

44 Changeover Switches Changeover Switches Manufactured to BSEN Parts 1 & 3. Robust enclosure powder coated to RAL7035. Removable end plates. TCO1004 Current Rating A (AC21) No. of Poles Cable Size (mm 2 ) H (mm) Steel Enclosures to IP31 W (mm) D1 (mm) TCO TCO TCO TCO TCO TCO TCO TCO TCO (M8) TCO (M8) TCO (M8) TCO (M8) TCO (M10) TCO (M10) TCO (M10) TCO (M12) TCO (M12) TCO D2 (mm) Current Rating A (AC21) No. of Poles Cable Size (mm 2 ) H (mm) GRP Enclosures to IP65 W (mm) D1 (mm) D2 (mm) CO/ CO/ CO/ CO CO/ CO/ CO/ CO/ CO/ CO/ H CO/ CO/ W D CO/ D (0)

45 Case Study Innovia Films PRO2000 Switchboards In March 2014, Innovia Films announced that they had signed a contract with the Bank of England for Innovia Security to supply Guardian polymer substrate for the next generation of UK sterling bank notes. Proteus Industrial has supplied Innovia Films since 2010 in an on-going programme of replacing much of their old switchgear with the latest, and in some cases totally bespoke, control equipment. By working closely with Neville Cox, Electrical Engineering Manager - OPP and his electrical team at Innovia, a new order has just been placed by City Electrical Factors (CEF) Carlisle branch, for two purpose built Pro2000 switchboards to distribute 400v power throughout the state of the art Innovia Security facility as part of the programme. Designed and built in the Proteus factory in Telford, Neville was able to see his switch board being built to his unique specification. As a British manufacturer ourselves it is great to be able to talk and actually see our own panel being built said Neville, I cannot think of another company left in the UK that could offer this service.

46 Busbar Chambers Busbar Chambers Manufactured to BSEN & 2. 4 pole configuration. 6 ratings from 100A to 800A. 36kA Icc. 100BC2 200BC3 300BC3 400BC4 600BC6 W H D Current Rating A Fully rated neutral. Twin bar design from 100A up to 800A. Set of 4 clamps supplied with each chamber. No. of Poles 100A Busbar Chambers H (mm) W (mm) D (mm) BC BC BC BC Current Rating A No. of Poles 200A Busbar Chambers H (mm) W (mm) D (mm) BC BC BC BC Current Rating A No. of Poles 315A Busbar Chambers H (mm) W (mm) D (mm) BC BC BC BC Current Rating A No. of Poles 400A Busbar Chambers H (mm) W (mm) D (mm) BC BC BC BC Current Rating A No. of Poles 630A Busbar Chambers H (mm) W (mm) D (mm) BC BC BC BC Current Rating A No. of Poles 800A Busbar Chambers H (mm) W (mm) D (mm) BC BC BC Higher ratings available on request (0)

47 Connection Bolts BLC6/23 Bolts to Suit Busbar Bolt Size (Metric) Max. Cable Size mm A rated M6 70 BLC6/ A rated M6 70 BLC6/48 M6 Bolt Size PROTEUS BLC8/23 Bolts to Suit Busbar Bolt Size (Metric) Max. Cable Size mm A rated M8 150 BLC8/ A rated M8 150 BLC8/48 M8 Bolt Size BLC10/48 M10 Bolt Size Bolts to Suit Busbar Bolt Size (Metric) Max. Cable Size mm 2 315A rated M BLC10/ A rated M BLC10/48 BCC185/48 Clamp Bolts to Suit Busbar Bolt Size (Metric) Max. Cable Size mm A rated Clamp 185 BCC185/ A rated Clamp 185 BCC185/ A rated Clamp 240 BCC240/48 BCC240/48 Busbar Chambers 45

48 ABS Enclosures ABS Enclosures Designed to meet protection and combustible standards IP65 and IK08. Available in 6 sizes. Supplied in grey (RAL 7035) with solid door and base unit (internal mounting plate). IP65E Wall thickness on the range is 3 3.5mm. Made from UL approved ABS-HB flame retardant plastic. Complying with BS EN 60529, BS EN 62208, CEI23-48 & CEI23-49 Multipurpose IP65 Enclosures Description H (mm) W (mm) D (mm) IP65 enclosure IP65E IP65 enclosure IP65E IP65 enclosure IP65E IP65 enclosure IP65E IP65 enclosure IP65E IP65 enclosure IP65E IP /CD Multipurpose IP65 Enclosures Description H (mm) W (mm) D (mm) IP65 enclosure IP65E302013/CD IP65 enclosure IP65E352515/CD IP65 enclosure IP65E403022/CD IP65 enclosure IP65E504024/CD IP65 enclosure IP65E604020/CD IP65 enclosure IP65E705025/CD H W D (0)

49 Contactors & Emergency Stops Compliant with BSEN , CSA approved and UL Listing. Terminal marking to EN Climate rating tested to DIN and IEC68. PC063230V Power Rating (kw) at 400V Standard 230V a.c. coil voltage. Generous cabling connections. Clear identification of contact position and function. Full range of auxiliary components. AC1 Rating A at 400V 3 Pole Contactors AC3 Rating A 3 Pole Cat. at 400V No PC020230V PC025230V PC032230V PC063230V PC100230V PC200230V Description Auxilliary contact, 1 NO & 1 NC, AC15 duty Auxilliary Contact PCS-11 Auxilliary contact is rated at 3A/220V a.c. PROTEUS HLC100 AC1 Rating A Enclosed Heating and Lighting Contactors AC3 Rating A Aux. Contacts Fitted H (mm) W (mm) D (mm) NO HLC NO HLC NO/1 NC HLC NO/1 NC HLC NO/1 NC HLC Conform to BSEN EM/STOP MEMI Description IP65 Emergency Stop Push Buttons Contact H (mm) W (mm) D (mm) Configuration Emergency Stop Push Button - 1NC EM/STOP Twist release N/C Contact Block To Suit EM/STOP - EMCB1NC N/O Contact Block To Suit EM/STOP - EMCB1NO Description IP65 Emergency Stop Push Buttons Contact H (mm) W (mm) D (mm) Configuration Neon Ind./Twist release* 1NO/1NC MEMI Key release* 1NO/1NC MEMK Twist release* 1NO/1NC MEMT Twist release* 1NO/1NC MEMSS N/C Contact Block To Suit MEM... - PCB1NC N/O Contact Block To Suit MEM... - PCB1NO Contactors & Emergency Stops 47

50 Earth Bars Earth Bars Earth Bars are manufactured from HDHC copper supported on glass reinforced polyester insulators. The CSA of the bar is nominally 150mm² (25mmx6mm / 1 x1/4 ) with a current rating of 400A and 300mm 2 (30mm x 10mm) for 800A. PEB8 L H W No. of Outgoing Connections The insulators are mounted on a steel top hat section for fixing to the wall. Mounted on insulated supports (may be used as neutral bars). 15kA Is, 30kA peak. 400A Earth Bars Integral Test Link L (mm) W (mm) H (mm) 4 No PEB No PEB No PEB No PEB Yes PEBTL Yes PEBTL Yes PEBTL Main bolt M12. Outgoing bolts M8. Up to 2000A ratings are available on request. PEBTL12/800 No. of Outgoing Connections 30kA Is, 63kA peak. 800A Earth Bars Integral Test Link L (mm) W (mm) H (mm) 6 No PEB6/ No PEB8/ No PEB12/ Yes PEBTL6/ Yes PEBTL8/ Yes PEBTL12/ Outgoing Connection size M8. Up to 2000A ratings are available on request (0)

51 Miniature Circuit Breakers Use the colour code to help identify the supplying Proteus Division for further technical data on circuit protection devices or visit: 601B 606C 1006/4 Current Rating (A) 6kA SP Cat No. 10kA SP 10kA DP 6kA TP 10kA TP 1 601B B 1002/ B 1004/ B 1006/ / B 1010/ / B 1016/ / B 1020/ / B B 1032/ / B 1040/ / B B 1050/2* /2* B 1063/2* /2* - * - 6kA rated. Current Rating (A) 6kA SP Cat No. 10kA SP 10kA DP 6kA TP 10kA TP B-Type 10kA 4P C-Type 10kA 4P 2 602C 1002/3-3602C 31002/ C 1004/3-3604C 31004/ C 1006/ /3 3606C 31006/ / C 1010/ /3 3610C 31010/ / C 1016/ /3 3616C 31016/ / C 1020/ /3 3620C 31020/ / C 1025/ /3 3625C 31025/ C 1032/ /3 3632C 31032/ / C 1040/ /3 3640C 31040/ / C 1050/3* 21050/3* 3650C 31050/3* 41050/3* C 1063/3* 21063/3* 3663C 31063/3* 41063/3* * - 6kA rated. Current Rating (A) 6kA SP Cat No. 10kA SP Blue Box - Consumer No Box - Industrial 10kA DP 6kA TP D-Type 10kA TP / / / / / / / / / / / / /4* /4* /4* /4* * - 6kA rated. 4 Pole MCBs cannot be fitted in MCB boards. Circuit Protection PROTEUS 49

52 Circuit Protection Residual Current Breaker With Overload Use the colour code to help identify the supplying Proteus Division for further technical data on circuit protection devices or visit: XL6BR 20MCRSPK Current Rating (A) Single Module RCBOs - 1Pole & Solid Neutral B - Type Type AC Type A 4.5kA Cat No. 6kA Com. 6kA Cat No. 10kA Cat No. 6 6MBRSP 6MBRSPK 66MBRSP XL6BR 10 10MBRSP 10MBRSPK 106MBRSP XL10BR 16 16MBRSP 16MBRSPK 166MBRSP XL16BR 20 20MBRSP 20MBRSPK 206MBRSP XL20BR 25 25MBRSP 25MBRSPK MBRSP 32MBRSPK 326MBRSP XL32BR 40 40MBRSP 40MBRSPK* 406MBRSP XL40BR 45 45MBRSP 45MBRSPK* - XL45BR * - 4.5kA rating. Current Rating (A) 4.5kA Cat No. Type AC 6kA Com. Blue Box - Consumer No Box - Industrial 6kA Cat No. Type A C - Type 10kA Cat No. 6 6MCRSP 6MCRSPK 66MCRSP XL6CR 10 10MCRSP 10MCRSPK 106MCRSP XL10CR 16 16MCRSP 16MCRSPK 166MCRSP XL16CR 20 20MCRSP 20MCRSPK 206MCRSP XL20CR 25-25MCRSPK - XL25CR 32 32MCRSP 32MCRSPK 326MCRSP XL32CR 40 40MCRSP 40MCRSPK* 406MCRSP XL40CR 45 45MCRSP 45MCRSPK* - XL45CR * - 4.5kA rating. 10MRBE Double Module RCBOs - 1Pole & Switched Neutral B - Type Current Rating (A) 4.5kA 6kA Com. 6kA 10kA Cat No. Cat No. Cat No MRBE** MRBE** MRBE** MRBE** MRBE** MRBE** - ** MRBE range are suitable for cable in-cable out applications and with DP comb busbar. All RCBOs and RCDs are fitted with a Test-Button facility which will check the detection and mechanical tripping function of the device, this must be operated regularly (0)

53 Residual Current Device Use the colour code to help identify the supplying Proteus Division for further technical data on circuit protection devices or visit: 25/2/30T Current Rating (A) Max. Cable Size (mm 2 ) Blue Box - Consumer No Box - Industrial Directional Type AC 2 Pole RCDs 30mA Sensitivity 100mA Sensitivity 300mA Sensitivity 500mA Sensitivity /2/30T 25/2/100T 25/2/300T 25/2/500T /2/30T 40/2/100T 40/2/300T 40/2/500T /2/30T 63/2/100T 63/2/300T 63/2/500T /2/30T 80/2/100T 80/2/300T 80/2/500T /2/30T 100/2/100T 100/2/300T 100/2/500T PROTEUS 25/2/30TA Directional Type A 2 Pole RCDs Current Rating (A) Max. Cable Size (mm 2 ) 30mA Sensitivity /2/30TA /2/30TA /2/30TA /2/30TA /2/30TA 25/4/30A 100/2/100D Bi-Directional Type A 4 Pole RCDs Current Rating (A) Max. Cable Size (mm 2 ) 30mA Sensitivity 100mA Sensitivity 300mA Sensitivity /4/30A /4/30A 40/4/100A /4/30A 63/4/100A /4/30A 80/4/100A /4/30A 100/4/100A 100/4/300A Supply can be connected to top or bottom terminals. Bi-Directional Time Delay RCDs Current Rating (A) Max. Cable Size RCD Sensitivity (ma) (mm 2 ) 100 (1P+N) /2/100D* 100 (3P+N) /4/100TD 100 (3P+N) /4/300TD Type S - Time delay >150ms. * - Directional When the load is connected to the supply through an RCD, the live and neutral conductors are connected through a primary winding on a toroidal transformer. In this arrangement the secondary winding is used as a sensing coil and is electrically connected to a relay or solid-state switching device, the activation of which triggers the mechanical tripping mechanism. When the live and neutral currents are balanced, as in healthy Residual Current Device - Principles of Operation. circuit they produce equal and opposite magnetic fluxes in the transformer core with the result that there is no current generated in the sensing coil. When the live and neutral currents are not balanced they create an out-of-balance flux. This will induce a current in the secondary sensing winding which is used to operate the tripping mechanism of the RCD. Circuit Protection 51

54 SPD - Surge Protection Surge Protection Proteus Switchgear offers a comprehensive range of Lightning and Surge Protection Devices for single and three phase applications. Whether it s a stand-alone SPD/T2/TNS4P device or a pre-assembled SPD in a distribution board, Proteus can provide a coordinated system to meet your specific requirements. SPD Type Earthing Internal Fuse Surge Protection Three Phase TN - S, TN - C - S N SPD/T12/TNS4P TN - S, TN - C - S Y SPD/T12/TNS4PIF TT N SPD/T12/TT4P TT Y SPD/T12/TT4PIF 2 TN - S, TN - C - S N SPD/T2/TNS4P 2 TN - S, TN - C - S Y SPD/T2/TNS4PIF 2 TT N SPD/T2/TT4P 2 TT Y SPD/T2/TT4PIF SPD/T3/PC SPD Type Earthing Internal Fuse Single Phase 1+2 TN-S, TN-C-S N SPD/T1/TN 1+2 TT N SPD/T1/TT 2 (1P+N) TN-S, TN-C-S N SPD/T2/TN 2 (1P+N) TT N SPD/T2/TT 2 (1P only) - N SPD/T2/SP 3 - N SPD/T3/SC 3 - N SPD/T3/PC 3 - N SPD/T3/LPC Insulated IP Enclosures SPD/T2/TNS4PE SPD Type IP Rating Earthing H (mm) W (mm) D (mm) 1+2 IP55 TN-S, TN-C-S SPD/T1/TNE IP55 TT SPD/T1/TTE (1P+N) IP55 TN-S, TN-C-S SPD/T2/TNE (1P+N) IP55 TT SPD/T2/TTE (1P only) IP55 - SPD/T2/SPE IP55 - SPD/T3/SCE IP55 - SPD/T3/PCE (3P+N) IP65 TN-S, TN-C-S SPD/T12/TNS4PE (3P+N) IP65 TT SPD/T12/TT4PE (3P+N) IP65 TN-S, TN-C-S SPD/T2/TNS4PE (3P+N) IP65 TT SPD/T2/TT4PE Type arrestor is suitable for supplies upto and including 315A. Type 2 arrestor is suitable for supplies upto and including 125A (0)

55 Surge Protection SPD/T12/TNS4PEF SPD/T2/TT4PES BX12S1TNS XL4S1TT BXS2TTK Blue Box - Consumer No Box - Industrial Steel Enclosures - With Integral Fuse SPD Type IP Rating Earthing H (mm) W (mm) D (mm) TN-S, TN-C-S SPD/T12/TNS4PEF TT SPD/T12/TT4PEF TN-S, TN-C-S SPD/T2/TNS4PEF TT SPD/T2/TT4PEF Type arrestor with integral fuse is suitable for supplies over 315A. Type 2 arrestor with integral fuse is suitable for supplies over 125A. Steel Enclosures - Without Integral Fuses SPD Type IP Rating Earthing H (mm) W (mm) D (mm) TN-S, TN-C-S SPD/T12/TNS4PES TT SPD/T12/TT4PES TN-S, TN-C-S SPD/T2/TNS4PES TT SPD/T2/TT4PES Type arrestor without integral fuse is suitable for supplies upto and including 315A. Type 2 arrestor without integral fuse is suitable for supplies upto and including 125A. Suitable For Use in TN-C-S/TN-S Systems Outgoing Ways BX Board 125A XL Board 125A Incomer Incomer 3 BX4S125TNS XL4S125TNS 5 BX6S125TNS XL6S125TNS 7 BX8S125TNS XL8S125TNS 11 BX12S125TNS XL12S125TNS 15 BX16S125TNS XL16S125TNS 19 BX20S125TNS XL20S125TNS 23 BX24S125TNS XL24S125TNS MCB Distribution boards c/w Type 2 surge protection suitable for use in TN-C-S / TN-S Systems Outgoing Ways BX Board 125A XL Board 125A Incomer Incomer 3 BX4S125TT XL4S125TT 5 BX6S125TT XL6S125TT 7 BX8S125TT XL8S125TT 11 BX12S125TT XL12S125TT 15 BX16S125TT XL16S125TT 19 BX20S125TT XL20S125TT 23 BX24S125TT XL24S125TT Three phase distribution boards with incomer of 200A rating require a conversion kit to introduce type 2 SPD protection. Type of 3ph Board TN-C-S TT TN-S-S BX BXS2TNSK BXS2TTK XL XLS2TNSK XLS2TTK A Type 2 SPD can be connected in parallel with the installation using one of our conversion kit / enclosures which incorporate the necessary Type 2, 3P+N SPD with backup fuse units rated at 125A. MCB Boards With Surge Protection PROTEUS 53

56 54

57 Circuit Protection Consumer Unit Division For over 30 years, Proteus Switchgear has been at the forefront of British manufacturing - specialising in the production of domestic consumer units and circuit protective devices, working proficiently to supply a full and varied product range. In addition to our standard product range, we have the ability to offer fully bespoke units, tailored to customer needs to suit any individual installation. At Proteus, we are entirely committed to the design and development of our products with the future in mind. Our values insist that we are continuously endeavouring to provide 100% tested products alongside features and benefits that allow us to excel within the Switchgear industry. 55

58 Consumer Units Selection and Configurations BS7671:2008 incorporating Amendment 3 is clear about the type of enclosure required for domestic (household) premises non-combustible (or metal) but the configuration can vary depending on the type of installation. This guide to Consumer Units has been compiled in order to assist in understanding the new wiring regulations. However it is not intended to be a substitute for BS7671:2008 which should always be consulted in order to ensure that all installations are constructed in accordance with these regulations. Is the Consumer unit being installed in a domestic (household) premise. (Reg ) i.e metalclad consumer unit. Proteus offers a full selection of consumer units to meet both the requirements of BS7671 and each individual application. danger caused by failure of a single circuit such as a lighting circuit. Reduce the possibility of tripping of an RCD due to excessive protective conductor currents (Reg ). Socket outlets up to 20A must be protected by a residual-current device (Reg ). All circuits containing a bath or shower must be RCD-protected (Reg ). To avoid hazards and minimise inconvenience in the event of a fault. Take into account the Unprotected cables buried less than 50mm deep in a wall must be RCD-protected. (Reg & ). Isolator Controlled Board RCBO / MCB RCBO / MCB RCBO / MCB RCBO / MCB RCBO / MCB E RCBO / MCB RCBO / MCB RCBO / MCB RCBO / MCB RCBO / MCB RCBO / MCB RCBO / MCB N RCBO / MCB RCBO / MCB Supply L N DP ISOLATOR Allows the use of single module RCBO devices for individual circuit protection at 30mA. Reduces risk of nuisance tripping. An earth fault on one circuit would not adversely affect other circuits in the installation. Can be used as main domestic Consumer Unit. See page 60 for Metalclad boards (68 for insulated boards) RCD Controlled Board MCB MCB MCB MCB MCB E MCB MCB MCB MCB MCB MCB MCB N MCB MCB Supply L N DP RCD Suitable for Grouped Circuit Protection of small numbers of circuits, usually downstream of main consumer unit. Typical applications include garages, showers and small extensions. If fed from main Consumer Unit also with RCD protection then earth leakage discrimination must be considered. Can be used as sub-distribution board, but should not be used as main domestic Consumer Unit. See page 61 for Metalclad boards (69 for insulated boards) (0)

59 Selection and Configurations N2 MCB MCB MCB MCB MCB MCB L DP RCD N RCBO / MCB RCBO / MCB RCBO / MCB E RCBO / MCB RCBO / MCB N1 RCBO / MCB Mains Supply L N DP ISOLATOR Split Load Board Offers both High Integrity ways of Isolator and Grouped Circuit Protection off RCD device. Unwanted tripping is limited / restricted. Variable units allow for increased High Integrity ways for dedicated circuit protection - e.g. Smoke Alarms. Can be used as main domestic Consumer Unit. PROTEUS N2 See page 62 for Metalclad boards N2 MCB MCB MCB MCB MCB L N DP RCD N2 MCB MCB MCB MCB E MCB L N DP RCD N1 N1 Mains Supply L N DP ISOLATOR Dual RCD Board Offers Grouped Circuit Protection using two 30mA RCDs Circuits can be segregated to reduce unwanted tripping, for example upstairs lights + downstairs ring main off RCD1 and downstairs lights + upstairs ring main off RCD2. Can be used as main domestic Consumer Unit. See page 62 for Metalclad boards N3 MCB MCB MCB MCB L E N DP RCD N3 MCB MCB MCB MCB L N2 N DP RCD N2 RCBO / MCB RCBO / MCB N1 Mains Supply L N DP ISOLATOR High Integrity Dual RCD Board High Integrity circuit ways off the isolator are available for dedicated circuit protection - i.e. Smoke Alarms. Dual 30mA RCD configuration offering Grouped Circuit Protection. Circuits can be segregated to reduce unwanted tripping. Can be used as main domestic Consumer Unit. See page 63 for Metalclad boards N RCBO / MCB RCBO / MCB RCBO / MCB RCBO / MCB RCBO / MCB RCBO / MCB Supply L2 DP ISOLATOR RCBO / MCB RCBO / MCB E RCBO / MCB RCBO / MCB N RCBO / MCB RCBO / MCB Supply L1 Supply N DP ISOLATOR N Dual Tariff Board For segregation of On Peak and Off Peak circuits. Optional split load and isolator incomer options available. Additional configurations available upon request. Can be used as main domestic Consumer Unit. See page 63 for Metalclad boards Consumer Units 57

60 Metalclad Consumer Units Metalclad Features & Benefits This new range of Metalclad Consumer Units from Proteus Switchgear has been designed in conjunction with contractors and housing authorities specifically to meet the requirements of Regulation of BS7671:2008 incorporating Amendment 3:2015. With its linear design and matt white (RAL9010) finish, the consumer unit offers the home owner a discreet and contemporary product, whilst providing suitable protection to meet today s need. AYXLM Range 1 Increased height for added cabling space Large rear knockouts with radius corners. Comb bus bar / Half Din Rail for quick fitting of devices. Captive screws with cage nut fixings. Full metal enclosure compliant to BS7671 Amendment 3:2015, Reg BS EN Compliant. Easy access for meter tail connections. Bespoke consumer units made to order (0)

61 Metalclad Features & Benefits Regulation calls for switchgear assemblies, including consumer units, to be housed in a noncombustible enclosure, incorporating the base, cover, door and any accessories. The Proteus AYXLM range meets these requirements and offers additional features providing a more versatile product for the installing contractor. PROTEUS Metalclad Consumer Units 59

62 Metalclad Consumer Units Isolator Incomer Consumer Units The Proteus AYXLM range of metal consumer units are designed and manufactured to BSEN61439 pt 3 and meets the requirements of BS7671:2008, Amendment 3:2015, regulation effects against thermal influences specifically for domestic household dwellings. AYXLM8U Outgoing Ways Isolator Rating RCD 1 Rating* Manufactured from steel and finished in a polyester powder coating to RAL9010, the AYXLM range provides a comprehensive selection of products to meet the customers requirements. Isolator Controlled Consumer Units RCD 2 Rating* H (mm) W (mm) D (mm) 2 63A - - AYXLM A - - AYXLM4U A - - AYXLM6U A - - AYXLM8U A - - AYXLM10U A - - AYXLM12U A - - AYXLM14U A - - AYXLM16U A - - AYXLM18U A - - AYXLM20U A - - AYXLM26U A - - AYXLM30* * - Double banked. Please refer to page 49 for circuit protection devices (0)

63 RCD Consumer Units The AYXLM range of RCD incomer metalclad consumer units are available with 63A, 80A and 100A RCD incomer ratings and 30mA earth leakage protection. For higher earth leakage protection, 100mA to 500mA, please contact our sales office for further details. PROTEUS AJBXM8U Outgoing Ways Isolator Rating RCD 1 Rating* RCD 2 Rating* RCD Incomer Consumer Units H (mm) W (mm) D (mm) 2-63A - AJBXM2U A - AJBXM4U A - AJBXM6U A - AJBXM8U A - AJBXM12U A - AKBXM2U A - AKBXM4U A - AKBXM6U A - AKBXM8U A - AKBXM12U A - ALBXM2U A - ALBXM4U A - ALBXM6U A - ALBXM8U A - ALBXM12U * - 30mA trip rating. Please refer to page 49 for circuit protection devices. Metalclad Consumer Units 61

64 Metalclad Consumer Units Dual RCD & Split Load Consumer Units This selection of Consumer Units offer the facility to spread the load circuits across one or two 30mA RCDs. Standard configurations listed below supplied with DP AYXLMJB5JB5U Outgoing Ways Isolator Rating RCD 1 Rating* RCD 2 Rating* Isolator and RCD/s factory fitted, link leads for both Live and Neutral connections also pre-installed. Dual RCD Consumer Units H (mm) W (mm) D (mm) 6 100A 63A 63A AYXLMJB3JB3U A 63A 63A AYXLMJB5JB5U A 80A 80A AYXLMKB5KB5U A 63A 63A AYXLMJB6JB6U A 80A 80A AYXLMKB6KB6U A 63A 63A AYXLMJB8JB8U A 80A 80A AYXLMKB8KB8U A 63A 63A AYXLMJB10JB10U A 80A 80A AYXLMKB10KB10U * - 30mA trip rating. Please refer to page 49 for circuit protection devices. AYXLMSLV12U Outgoing Ways Isolator Rating RCD 1 Rating* RCD 2 Rating* Split Load Consumer Units H (mm) W (mm) D (mm) 6 100A 63A - AYXLMSLV6U A 63A - AYXLMSLV12U * - 30mA trip rating. Please refer to page 49 for circuit protection devices (0)

65 High Integrity & Dual Tariff Consumer Units For applications where High Integrity circuit protection is required, for example smoke detectors, these units allow dedicated RCBO installation. Our standard range of dual tariff consumer units provide dedicated segregation of on peak and off peak circuits. PROTEUS AYXLM2JB4JB4U Outgoing Ways Isolator Rating RCD 1 Rating* High Integrity Dual RCD Consumer Units RCD 2 H (mm) W (mm) D (mm) Rating* 6 100A 63A 63A AYXLM1JB2JB3U A 63A 63A AYXLM2JB4JB4U A 63A 63A AYXLM2JB5JB5U A 63A 63A AYXLM2JB6JB6U A 80A 80A AYXLM4KB8KB8U A 80A 80A AYXLM4KB8KB8U A 63A 63A AYXLMDSLV6U A 63A 63A AYXLMDSLV10U A 63A 63A AYXLMDSLV12U A 80A 80A AYXLMDSLV16U A 80A 80A AYXLMDSLV22U * - 30mA trip rating. Please refer to page 49 for circuit protection devices. AYXLMJB5JB5Y4U Dual Tariff Consumer Units On Peak Off Peak H (mm) W (mm) D (mm) 100A isolator 6 ways 100A isolator 2 ways AYXLM6Y2U A isolator 8 ways 100A isolator 4 ways AYXLM8Y4U A isolator 8 ways 100A isolator 6 ways AYXLM8Y6U A isolator 10 ways 100A isolator 4 ways AYXLM10Y4U A isolator 12 ways 100A isolator 4 ways AYXLM12Y4U A isolator 12 ways 100A isolator 6 ways AYXLM12Y6U A isolator 10 ways 100A isolator 10 ways AYXLM10Y10U & 3 Dual RCD 100A isolator 2 ways AYXLMJB3JB3Y2U & 4 Dual RCD 100A isolator 4 ways AYXLMJB4JB4Y4U & 5 Dual RCD 100A isolator 4 ways AYXLMJB5JB5Y4U Other configurations available upon request, please speak to our sales office. Metalclad Consumer Units 63

66 Metalclad Consumer Units Enclosures & Garage / Shower Units The AYXLM range offers a selection of din rail mount enclosures for building your own switchgear assembly. A range of Garage and Shower Units are also available APXLM10U ensuring compliance with Regulation of BS7671:2008 incorporating Amendment 3:2015. Metalclad Enclosures No. Of Banks H (mm) W (mm) D (mm) Modules 6 1 APXLM6U APXLM10U APXLM12U APXLM16U APXLM18U APXLM22U APXLM28U Please refer to page 49 for circuit protection devices. APGU2 Outgoing Ways Isolator Rating RCD 1 Rating* MCB Rating* Garage & Shower Units H (mm) W (mm) D (mm) 2-40A 6A + 16A APGU A 6A + 16A APGU4M A 40A APSU A 50A APSU Please refer to page 49 for circuit protection devices (0)

67 Metalclad Accessories To compliment the AYXLM range of Metalclad consumer units, a selection of spacer mounts are available for use where retrofitting to surface mount cables are necessary. In addition, Meter Tail glands are available for providing Class II insulation protection for incoming supply cables. PROTEUS ASM12 Consumer Unit Spacer Mounts No. Of Banks H (mm) W (mm) D (mm) Modules 6 1 ASM ASM ASM ASM ASM ASM ASM Meter Tail Gland Pack Description Dia (mm) Meter tail gland pack (2x25mm / 1x 16mm) M32 - brass MTGP32B 32 Meter tail gland pack (2x25mm / 1x 16mm) M40 - brass MTGP40B 40 Meter tail gland pack (2x25mm / 1x 16mm) M32 - plastic MTGP32P 32 MTGP40B AKL Meter tail gland pack (2x25mm / 1x 16mm) M40 - plastic MTGP40P 40 Meter tail reducer 40-32mm MTGPR40/32 - Safety Accessories Description Key lock for A type metalclad consumer units AKL Intumescent putty pad (210mm x 148mm x 3mm) IP21X15 Metalclad Consumer Units 65

68 Insulated Consumer Units Insulated Features & Benefits The YXL range of Consumer Units has quickly become one of the most innovative insulated boards in the market. Developed through a keen interest in customer feedback, Proteus Switchgear created a Consumer Unit that was flexible to any imaginable on-site scenario. The YXL Range various options available include Dual RCD units and also Dual RCD units with High Integrity option - suitable for single module RCBO devices, offering complete peace of mind for those essential circuits requiring 1 Unique stacking system Removable endplates for maximum cable access. Comb bus bar / Half Din Rail for quick fitting of devices. Rear, side and top/bottom cable entries. 5 Captive four point 1/4 turn cover fixing screws Increased height for added cabling space. BS EN Compliant. Translucent front door. Manufactured from thermoplastic materials to BS Bespoke consumer units made to order (0)

69 Insulated Features & Benefits dedicated earth fault protection. In this range, Proteus Switchgear also offer the largest single bank insulated Consumer Unit on the market, the 25-module Consumer unit, with up to 23 outgoing circuit ways. Insulated Consumer Units PROTEUS 67

70 Insulated Consumer Units Isolator Incomer Consumer Units Readily available from 1 to 30 usable ways, our Isolator Incomer Consumer Units allow the use of single module RCBO devices for individual circuit protection at 30mA, reducing the risk of nuisance tripping. YXL6 Outgoing Ways Isolator Rating (A) No. of Modules Our insulated enclosures are manufactured from light grey impact resistant and flame retardant thermoplastic. Isolator Controlled Consumer Units H (mm) W (mm) D1 (mm) D2 (mm) YXL1* YXL2* YXL3* YXL4* YXL YXL YXL YXL YXL16* ** YXL YXL21* YXL23* ** YXL For Isolator controlled Consumer Units with over 30 outgoing ways contact factory for availability. * - Cannot be banked ** - Double banked unit *** - Triple banked unit YXL# units are supplied with translucent cover. Please refer to page 49 for circuit protection devices (0)

71 RCD Incomer Consumer Units Readily available from 1 to 12 usable ways, our RCD Incomer Consumer Units are suitable for grouped circuit protection for a small number of circuits, typically installed in addition to a property s main Consumer Unit applications such as garages, showers and small extensions. Our ranges of RCD Incomer Consumer Units are pre-fitted with a 30mA RCD Incomer, with ratings ranging from 25A 100A. PROTEUS GBX4 RCD Controlled Consumer Units Outgoing Ways Isolator Rating (A) No. of Modules Standard Range H (mm) W (mm) D1 (mm) D2 (mm) 1 25A 4 GBX1* A 4 GBX2* A 6 GBX3* A 6 GBX4* A 4 HBX1* A 4 HBX2* A 6 HBX3* A 6 HBX4* A 10 HBX A 4 JBX1* A 4 JBX2* A 6 JBX3* A 6 JBX4* A 10 JBX A 10 JBX A 14 JBX A 14 JBX A 6 KBX4* A 10 KBX A 10 KBX A 14 KBX A 14 KBX A 10 LBX A 10 LBX A 14 LBX A 14 LBX RCD incomer units are available in higher earth leakage sensitivity options on request. * - Insulated boards which cannot be banked. Please refer to page 49 for circuit protection devices. Insulated Consumer Units 69

72 Enclosures/Multi-Purpose Units Enclosures/Multi-Purpose Units Build your own consumer unit or multi-purpose board. Just clip on your required equipment to the DIN Rail and if necessary fit the Comb Busbar. Fitted with full DIN rail, Earth and Neutral terminal bars. PXL4 No. Of Modules Multi-Purpose Units H (mm) W (mm) D1 (mm) D2 (mm) 4 PXL4* PXL6* PXL PXL PXL18* PXL20** PXL25* PXL32** * - Insulated enclosures which cannot be banked. ** - Double banked unit. Please refer to page 49 for circuit protection devices. ENC654 Insulated IP Enclosures Surface mounting units suitable for use with Proteus modular isolation and protection devices to provide local or individual circuit control eg. Workshop. For extra wiring room order extended enclosures eg. ENC202ML or ENC204ML. No. of IP Rating H (mm) W (mm) D (mm) Modules 1 or 2 20 ENC202* ENC204* ENC ENC ENC ENC ENC ENC ENC ENC ENC ENC ENC * - Enclosure supplied without transparent front cover. Please refer to page 49 for circuit protection devices (0)

73 Sheffield City Council New Build Homes Case Study As part of a new build project, Sheffield City Council chose Proteus Switchgear to develop a range of Flush-Mounted Consumer Units to incorporate a dual RCD / high integrity configuration including a PV monitoring and data-logging/transmission module. The units were designed to meet the requirements of Amendment 3:2015 of BS7671: Requirements for Electrical Installations.

74 Meter Isolator Products Metering Isolators & Terminals Single and three phase isolator switches specifically for metering applications. Facility to seal the enclosure cover and incoming bottom connections, allowing the outgoing top connections to be made at a later stage. EMIS Description H (mm) Removable terminal cover can also be sealed if required. Entry holes will accommodate 25mm 2 double insulated or 35mm 2 single insulated cable. Single & 3 Phase Isolators W (mm) D (mm) Terminal Capacity 100A 1P+N isolator EMIS upto 35mm 2 100A 1P+N isolator - LHS neutral EMISN upto 35mm 2 24Hr/Off peak insulated EMIS upto 35mm 2 100A 3P+N isolator EMIS4P upto 35mm 2 Description H (mm) Single & 3 Phase Heating Contactors W (mm) D (mm) Terminal Capacity 100 Amp heating contactor EHC upto 35mm Amp heating contactor, EHC1L upto 35mm 2 switched live version 100 Amp heating contactor, 3 phase version EHC upto 35mm 2 EHC1 ETB5 Description H (mm) W (mm) Terminal Block D Terminal (mm) Capacity 100A 5 Way terminal block ETB upto 35mm 2 100A 5 Way terminal block, blue ETB5BL upto 35mm 2 100A 5 Way terminal block, brown ETB5BR upto 35mm 2 Kilowatt Hour Meters Description No. of Modules 45A Direct connect MID approved kwh meter KWH45AMID 1 100A Direct connect MID approved kwh meter KWH100AMID 2 KWH100A (0)

75 Switch Fuse & Fire Alarm Switches Surface mounting switch disconnector fuse unit in robust steel enclosure with an epoxy powder coated paint finish. Unit is designed to accommodate fuselinks to BS88: Part 1,2 & 6. All switches are lockable in ON and OFF position. SF20 Current Rating Capacity In (mm 2 ) Double Pole HRC Switch Fuses Capacity Cat No. H (mm) W (mm) D (mm) Out (mm 2 ) SF SF SF SF SF SF100/ SF DP Isolator can be locked in the ON or OFF position using DLPX1. PROTEUS FS1 TPS30 Description Capacity In (mm 2 ) Capacity Out (mm 2 ) Fire Alarm Panel Switch Cat No. H (mm) W (mm) D (mm) Metalclad unit FS Description For use when connecting a fire alarm to a public or private power distribution supply. Key features: Compliant with B5839 pt & BSEN54 pt Three module steel enclosure. Powder coated red in colour. 45A DP Isolator and 6A Type B SP MCB fitted Both devices can be locked in the ON position using locking accessories supplied. Metalclad surface mounting enclosure with both top and bottom knockouts. Ingress protection: IP20. (NB: MCB will trip under fault conditions even when lock is fitted). Capacity In (mm 2 ) Capacity Out (mm 2 ) 4 pole Isolator Switch AC21B Cat No. H (mm) W (mm) D (mm) 32A TPS Surface mounting 4pole switch disconnectors compliant with IEC with AC21B utilisation category. This unit offers a high impact resistant metalclad enclosure with facility to lock the switch in ON and OFF positions. Switch Fuse/Fire Alarm Switches 73

76 Three Phase Consumer Units Three Phase Consumer Units When space is limited and the installation requires a three phase distribution board, the range of Proteus TPX consumer units is the solution. A choice of 1 to 4 outgoing TP ways fed via a 3-phase TPXIC4 TPXIPC1 No. of Modules comb busbar arrangement are available in either insulated, metalclad or IP55 enclosures. All units are pre-fitted with 100A TP Isolator incomer and busbar to suit. Insulated Enclosures H (mm) W (mm) D1 (mm) D2 (mm) 1 TPXIC TPXIC2 * TPXIC3 ** TPXIC4 ** * - Will accept metal gland plate MGP2. ** - Will accept metal gland plate MGP3. Please refer to page 49 for circuit protection devices. No. of Modules IP55 Enclosures H (mm) W (mm) D (mm) 1 TPXIPC TPXIPC TPXIPC TPXIPC Please refer to page 49 for circuit protection devices. No. of Modules Metal Enclosures H (mm) W (mm) D (mm) 1 TPXMC TPXMC TPXMC Please refer to page 49 for circuit protection devices. TPXMC (0)

77 PROTEUS Gainsborough Hotel Finning UK Flush Mount Consumer Units As part of a major refurbishment program by Finning UK, Proteus Flush Mount Consumer Units were selected for the prestigious 100 bedroom Gainsborough Hotel in Bath. Case Study The units were supplied pre-assembled with SCPDs and contactors already fitted, ready for immediate installation. In addition, provision was made in the Consumer Units to mount a secondary heating controller supplied by the contractor. 75

78 Timers Digital, Mechanical & Staircase Timers A range of digital, mechanical & staircase timers available in 24-hour or 7-day options, predetermining the scheduling of automated switching options. No. of Channels Current Rating (A) Resistive Load ST ST Digital Timers 71ST Wiring schematic and Dimensions/Terminal arrangement 1 channel digital timer 2 channel digital timer L CH L L CH M LOAD M LOAD L N N N CH1 N L N 60.0 Mechanical Timers No. of Channels Module Size 1 Channel 24hr synchronous timer 16A rated 241S 1 2 Channel 24hr synchronous timer 16A rated 242S 3 1 Channel 24hr quartz timer 16A rated 241SQ 1 2 Channel 24hr quartz timer 16A rated 242SQ 3 242S Wiring schematic and Dimensions/Terminal arrangement 1 NO contact 24hr Changeover contact 24hr LOAD LOAD L N 1 M No. of Channels L N M Staircase Timers Staircase timer switch 1 module 1SCT Staircase timer switch 1 module c/w pre-warn function 1SCT/P* * Pre-warn function ensures that the timed light circuit flashes on and off several times before fully switching off. 1SCT Dimensions/Terminal arrangement 3-wire 4-wire L 1 L N 2 N 2 L N L N L 1 N (0)

79 Contactor & Isolators Proteus contactors are available from 20A up-to 63A in 2pole and 4pole options, suitable for din-rail mounting in consumer units fitted with full standard din-rail. Contactors offer method of remote switching of loads CT202 Current Rating (A) Voltage Rating (V) Power at Rated Voltage AC 1 (kw) and are suitable for AC1 switching - general heating and lighting loads. All contactors supplied with normally open (NO) contacts. Standard: EN Power at Rated Voltage AC 3 (kw) Contactors - Normally Open No. of Poles No. of Modules Cat. No CT CT CT CT634 PROTEUS CT202NC Current Rating (A) Voltage Rating (V) Power at Rated Voltage AC 1 (kw) Contactors - Normally Closed Power at No. of No. of Rated Voltage Poles Modules AC 3 (kw) CT202NC CT204NC CT404NC CT634NC Dimensions/Terminal arrangement 2 pole contactor 4 pole contactor A A A A A2 A S Current Rating (A) Isolators DP TP 4P 45 45S2 45S S2 63S3 63S S2 100S3 100S4 Key features: Choice of current ratings from 45A up to 100A. Operating dolly can be locked in ON or OFF state. Neutral pole designed to make first / break last. Positive contact status indication therefore can be used as an isolating switch. Switch disconnector is designed to accept cable-in/cable-out and direct to busbar connection. Contactors & Isolators 77

80 Accessories Accessories Description Blanking plate Barriers & Locking B1 Busbar terminal shroud Blanking module MCB Dolly locking device BBS1 BM1 DLPX1 BM1 MCB Dolly locking device c/w padlock DLPX1P CB19SP Description Insulated comb busbar 19 SP ways Insulated comb busbar 28 SP ways Insulated comb busbar 8 DP ways Insulated comb busbar 12 DP ways Insulated comb busbar 7 TP ways Insulated comb busbar 12 TP ways End Cap For DP/TP Insulated comb busbar Cable terminal for insulated comb busbar Insulated Comb Busbars * CB19SP CB28SP CB8DP CB12DP CB7TP CB12TP CBC3 CBCT1 * - 80A max. 100A intermittent rating (0)

81 Accessories TB8 Brass Terminal Bars Description 5 Hole terminal bar TB5 8 Hole terminal bar TB8 10 Hole terminal bar TB10 12 Hole terminal bar TB12 14 Hole terminal bar TB14 16 Hole terminal bar TB16 PROTEUS PXS100 Description 20A BS88 HRC Fuse 32A BS88 HRC Fuse 40A BS88 HRC Fuse 50A BS88 HRC Fuse 63A BS88 HRC Fuse 63A BS88 HRC Fuse (Fits SF100 & SF100/80) 80A BS88 HRC Fuse 100A BS88 HRC Fuse BS88 Fuses (Offset Tag) PES20 PES32 PES40 PES50 PES63 PXS63 PXS80 PXS100 BS88 Fuses Description 20A BS88 HRC Fuse PMS20 32A BS88 HRC Fuse PMS32 40A BS88 HRC Fuse PMS40 50A BS88 HRC Fuse PMS50 PMS100 63A BS88 HRC Fuse 63A BS88 HRC Fuse (Fits SF100 & SF100/80) 80A BS88 HRC Fuse 100A BS88 HRC Fuse PMS63 PMS63 PMS80 PMS100 Accessories 79

82 Specials Custom Built Consumer Units At Proteus, our custom build service ensure we design and manufacture a diverse range of insulated and metalclad consumer units to meet your specific requirements. Bespoke Units Insulated, IP rated or metalclad units. Multiple distribution options. Optional circuit control devices. Pre-wired short circuit protective devices. Fully tested assembly. Multiple Banked Units Larger than average homes require larger than the average Consumer Units, building bulk quantities to specification is made simple when specifying Proteus Switchgear. Street Lighting Applications Special locations often require special solutions. A street lighting application demanded a compact unit incorporating Double Pole RCBO, a 2 pole contactor and a 7 day digital timer. Proteus Switchgear were able to offer a pre-cabled and configured unit with electrical noise suppression component included to meet this customers specification (0)

83 Mantel Consumer Units Proteus offer a variety of Mantel Consumer Units (also known as skeleton or spine units) to meet and comply with the recent changes in the wiring regulations. Designed and developed with the needs of both the installer and installation conditions in mind these units offer Key features: 16 module units. Pre-wired switchgear where applicable. Clean cover plate / barrier of non-combustible material. PROTEUS SK3JB12 Outgoing Ways Isolator Rating RCD 1 Rating* RCD 2 Rating* Split Load Spine Units RCD Type H (mm) W (mm) D (mm) A DP 30mA SK3JB A DP 30mA SK4JB A DP 30mA SK5JB A DP 30mA SK6JB A DP 30mA SK7JB up-to 7 up-to 7-63A DP 30mA SKSLV Please refer to page 49 for circuit protection devices. Dual RCD Spine Units RCD Type H (mm) W (mm) D (mm) SKJB5JB5 Outgoing Isolator RCD 1 RCD 2 Ways Rating Rating* Rating* A DP 30mA SKJB4JB A DP 30mA SKJB5JB Please refer to page 49 for circuit protection devices. High Integrity & Dual RCD Spine Units RCD Type H (mm) W (mm) D (mm) SKSLV6R4 Outgoing Isolator RCD 1 RCD 2 Ways Rating Rating* Rating* 10 up-to A DP 30mA SKSLV6R A DP 30mA SK2JB4JB Please refer to page 49 for circuit protection devices. Mantel Units 81

84 Technical Information Technical Information Proteus MCBs are of thermo-magnetic, current limiting type and are available in a range of ka ratings (4.5kA up to 10kA) and operating characteristics (Type B, C and D). A selection of SP (single pole), DP (double pole) and TP (triple pole) options are offered. All MCBs have a trip free mechanism. Standards: Operating voltage: Operating frequency: Ambient operating temp.: Maximum terminal torque: Enclosure material: Supply: IP rating: Dielectric voltage: Insulation voltage: Positive contact status indication in accordance with IEE wiring regulations. Tunnel design, touch proof and captive terminals. Can be used as isolating switches. Lockable in both ON and OFF state without affecting the ability of the trip mechanism to operate. General Specification BSEN / 400V a.c. 50Hz -5C to +40C 3Nm (2.5Nm advised) Urea or V0 rated Polyamide (self extinguishing at 960C) Can be supplied from top or bottom. IP4X (front face) IP20 (terminals) 2500V a.c. 500V a.c. Miniature Circuit Breakers MCB Tripping Curves B C D I / In Type Instantaneous Circuit Applications Tripping Range B 3-5 Used in domestic situations where maximum sensitivity is required and very little equipment with high start-up current is connected. C 5-10 Suitable for commercial / industrial situations where close protection is not required and start up currents of devices can run upto 5 times rated current for a short period. Where many low voltage lights are used in a domestic situation then, due to the inrush currents of the transformers, type C MCBs may be required to avoid nuisance tripping. D Suitable for industrial application where start-up currents may be up to 10 times rated current, for example protection for machines with electric motors fitted, welding units etc. Seconds Minutes Steady current value 1.13xIn: t>1hr All MCBs are capable of carrying full load current continuously (derating factors apply for ambient conditions and no. of circuits within an enclosure). Steady current value 1.45xIn: t<1hr As load current increases above current rating the thermal release mechanism will disconnect MCB. 3xIn: 0.1sec<t<45sec (In<=32A) 3xIn: 0.1sec<t<90sec (In>32A) MCB will trip within times specified. 5xIn: t<0.1sec B-type MCB ensured to trip in less than 0.1sec via magnetic release. MCB Installation Voltages Type B & C 1 pole 230V-400V AC Type B & C Multi-pole 400V AC B-Type Terminal Capacities Range of MCBs Capacity (mm 2 ) MCBs RCBOs RCDs (<100A) RCDs (100A) Isolators 5xIn: 0.1sec<t<15sec (In<=32A) 5xIn: 0.1sec<t<30sec (In>32A) MCB will trip within times specified. 10xIn: t<0.1sec C-type MCB ensured to trip in less than 0.1sec via magnetic release. 10xIn: 0.1sec<t<4sec (In<=32A) 10xIn: 0.1sec<t<8sec (In>32A) MCB will trip within times specified. 20xIn: t<0.1sec D-type MCB ensured to trip in less than 0.1sec via magnetic release. t = Tripping time 25mm 2 (In and Out) 25mm 2 (In) ; 10mm 2 (Out) 35mm 2 (In and Out) 50mm 2 (In and Out) 35/50mm 2 (In and Out) Earth and Neutral bars 25mm 2 and 16mm 2 C-Type D-Type 82

85 Technical Information Adjacent MCBs, RCBOs or MCB/RCD combinations should not be continuously loaded at, or approaching, their normal rated currents when mounted in enclosures. It is also good engineering practice to make provisions for adequate free air between devices. Under these circumstances and, in common with other Switchgear Derating manufacturers, we recommend a diversity factor of 66% is applied to the MCB nominal rated current, especially if the MCB is expected to be loaded near to or at full rating for more than one hour. Thermal issues should also be taken into consideration when choosing conductor size for the protected circuits. PROTEUS Generally the MCBs detailed are not intended to provide close overload protection for motors. However they can be employed in conjunction with the customary motor overload current device as an alternative to the isolator/fuse combination. In this condition the MCB will protect the cable to the motor and the motor will be protected by its own protective device. The tables A and B detailed below give recommendations on MCB selection for motor circuits, for C type only. Note: The values of full load current and starting current will approximately be 10% higher at 380/220V ac than the figures MCB Installation Currents stated for 400/230V motors. The figures given in table A for the starting current and its duration are intended to be used as a guide only. In practice the motor run up time will depend upon the type of drive and the loading of the motor when it is started. Consultation with the motor manufacturer should give an indication of the magnitude of the starting current and the duration. The selection of the most suitable circuit breaker can then be found from the time/current characteristics of the circuit breaker. Table A: Recommended MCB current ratings for the protection of cables to single phase 230V a.c. motors. Horse Power (HP) Power (kw) FLC (A) Starting Current (A) Duration of Starting Current (sec) MCB Current Rating (A) Maximum Earth fault loop impedance (ie Zs ohms) for circuits supplying socket outlets in accordance with BS7671 regulation V (230V x 0.95 Cmin) BS7671: 2008 requirements: Electrical installations (17th Edition as overcurrent protective devices is not precluded, but the use of the IEE Wiring regulations) specifically identifies Type B and C. of residual current circuit breakers (RCDs) to provide protection Lower earth fault loop impedance s (Zs) are generally necessary against indirect earth fault condition is implied. Establishment for Type D to achieve the operating times required by regulation of the value of the earth fault loop impedance (Zs) at the design (Maximum Zs is calculated using the formula in the stage of installation will determine which type of circuit breaker regulations and the characteristics of the circuit breaker). Where should be used. the requirement can not be achieved, use of the circuit breakers Device Standard 6A 10A 16A 20A 32A 40A 50A 63A 80A 100A 125A Type B BSEN Type C BSEN Type D BSEN At these levels of earth loop impedance, MCBs will provide disconnection times in accordance with BS7671 for circuits supplying socket outlets. Technical Information 83

86 Technical Information Technical Information Table B: Recommended MCB current ratings for the protection of cables to three phase 400V a.c. motors. Horse Power (HP) Power (kw) FLC (A) Starting Current (A) Duration of Starting Current (sec) MCB Current Rating (A) Starting Current (A) Duration of Starting Current (sec) MCB Current Rating (A) Providing both overcurrent protection and earth leakage protection in a combined unit, Proteus offers a range of RCBOs which will fit all Proteus modular consumer units and B-type 3-phase distribution boards. RCBOs are available in a range of current ratings from 6A to 50A and with short circuit capacities (Ics) from 4.5kA up to 10kA. RCBOs are offered in both type B and C tripping characteristics. All single module RCBOs contain a switched live and solid neutral where as the double module unit offers both Live and Neutral switching. Similar to our MCB technology all devices have a trip free Standards: Operating voltage: Earth leakage sensitivity: Switching: Operating frequency: Ambient operating temp.: Maxi. terminal torque: Enclosure material: Supply connections: IP rating: Dielectric voltage: Insulation voltage: RCBOs mechanism and positive contact status indication. Connection of load circuit cables is via tunnel design cable clamps with touch proof and captive terminal screws. Lockable in both ON and OFF position without affecting the ability of the trip mechanism to operate. RCBOs allow earth fault protection to be restricted to individual circuits, thus ensuring that only the circuit with the fault is interrupted. (When groups of circuits are protected by an RCD, all circuits would be interrupted under a fault condition, which may cause unnecessary inconvenience). General Specification BSEN V a.c. 30mA Single pole - L (switched) + N (solid) Double pole - L + N (switched) 50Hz -5 C C 2Nm Urea or VO rated PBT (both self extinguishing at 960 C) Consult specific product data sheet IP4X (front face); IP20 (terminals) 2500V a.c. 500V a.c. 84

87 Technical Information Proteus RCDs are available in a wide range of earth leakage sensitivities and current ratings to meet the majority of applications. Residual Current Devices (RCDs) come in both 2 pole and 4 pole options. Proteus RCDs incorporate the latest in electronic earth leakage detection technology ensuring consistent reliable performance. With sufficient contact gap, switching of all Live and Neutral conductors and positive contact indication in accordance with the IEE wiring regulation these devices can be used for isolation purposes. RCDs also incorporate trip free mechanism technology and can be locked ON or OFF with suitable locking device (eg. DLPX1) without affecting the devices ability to offer protection under fault conditions. RCDs General use RCDs for domestic single phase or light commercial three phase systems are required to be either Type AC or Type A. This type reference defines the nature of the earth leakage which the RCD is expected to detect and protect against. Type AC: Tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising. Identified by the symbol: Type A: Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising. Identified by the symbol: PROTEUS Standards: Operating voltage: Operating frequency: Ambient operating temp.: Maxi. terminal torque: Enclosure material: Supply connections: IP rating: Dielectric voltage: Insulation voltage: General Specification BSEN P-230V a.c. 4P-230/400V a.c. 50Hz -5 C C 2.5Nm VO rated polyamide or PBT (both self extinguishing at 960 C) Consult specific product data sheet IP4X (front face); IP20 (terminals) 2500V a.c. 500V a.c. Type 1 SPDs are key to providing necessary protection of the installation against the effects of lightning strikes entering the building. Type 1 SPDs are designed to carry partial lightning currents and are defined as being tested with a high energy 10/350μs (Iimp) wave shape. These Type 1 SPDs must be installed on incoming services (e.g. mains power and data) when an external Lightning Protection System (LPS) is installed on a building. Where partial lightning currents can also flow due to a direct lightning strike on overhead supplies or externally mounted equipment, Type 1 SPDs should also be used. Combined Type `1 + Type 2 SPDs are installed at the origin of the supply to the building, normally within the main switchboard. If the installation being protected is already fitted with an SCPD of 315A or less then the SPD can be connected direct to the busbar otherwise ensure the device is adequately protected. In installations where it is not possible to fit a fuse or circuit breaker the IF (Internal Fuse) version is available. Type 2 SPDs in this modular form offer more general surge protection for equipment within the installation from sources of problematic electrical surges internal to the building (typically switching transients). If the installation being protected is already fitted with an SCPD of 125A or less then the SPD can be connected direct to the busbar otherwise ensure the device is adequately protected. In installations where it is not possible Surge Protection Devices to fit a fuse or circuit breaker the IF (Internal Fuse) version is available. Their protection is limited by distance with a general protection zone of <10m. Equipment further away necessitate the installation of an additional Type 2 units in sub-distribution boards. Type 2 and Type 3 SPDs are designed to discharge the induced surges created by lightning electromagnetic fields and also other transient surge events such as switching surges, supply faults etc. These devices are defined as being tested with a specific energy wave shape of 8/20μs (In) for Type 2 SPDs or a combination wave shapes for Type 3 SPDs. For many applications where the requirement is to provide surge protection only, Type 2 and Type 3 SPDs play a critical role in protecting electronic equipment. Type 3 SPDs provide the primary fine protection from surges, giving high sensitive equipment that added level of security. As a rule they should be installed as close as possible to the equipment being protected. This class of product is available in both din-rail mounting version or remote/local installation. For example the SPD/ T3/LPC can be wired into the back of a plug socket feeding a certain piece of equipment. The SPD/T3/LPC has also the benefit of an audible alarm, for when the unit requires replacing. Technical Information 85

88 Technical Information Technical Information The below table lists only categories applicable to BSEN Switches, Disconnectors, Switchdisconnectors and Fuse-combination units. IEC Utilization Categories for Low Voltage Switchgear Current Category Typical Application AC AC - 20 Connecting and disconnecting under no-load conditions AC - 21 AC - 22 AC - 23 Moulded case circuit breakers are not in themselves intended to afford close thermal protection on motor circuits. However, when used in tandem with any intrinsic motor overload device they provide an excellent alternative to the combined isolator and fuse arrangements. In this case the motor is protected by its own circuit breaker. In order to select the correct MCCB, consideration should be given to individual MCCB time/current characteristics (for full details please refer to works). This should only be undertaken in Switching of resistive loads including moderate overloads Switching of mixed resistive and inductive loads, including moderate overloads Switching of motor loads or other highly inductive loads DC DC - 20 Connecting and disconnecting under no-load conditions DC - 21 DC - 22 DC - 23 The letter A or B can be suffixed dependent on whether the intended application requires frequent (A) or infrequent (B) operation. [For full details consult the full chart in BSEN ] Switching of resistive loads including moderate overloads Switching of mixed resistive and inductive loads, including moderate overloads Switching of motor loads or other highly inductive loads Moulded Case Circuit Breakers MCCB Protection of Motor Circuits conjunction with information provided by the motor manufacturer as to starting current and duration. The motor protection table shown provides a guide to MCCB selection based on the start current and duration indicated and it must always be noted that the drive and motor loading will affect the motor run up time. (i) The figures shown are based on the assumption that the motor starting conditions are: Direct On-Line =7 x full load current for 5 seconds max. Motor Rating (kw) Motor Rating (HP) Approx. FLC (A) at 400V Direct On Line MCCB Type/ Current Rating < 5.5 < 7.5 < A MC016T < 11 < 15 < A MC025T < 15 < 20 < 30 32A MC032T < 18 < 25 < 36 40A MC040T < 22 < 30 < 43 50A MC050T < 30 < 40 < 58 63A MC063TMR < 37 < 50 < 72 80A MC080TMR < 45 < 60 < A MC100TMR < 55 < 75 < A MC125TMR < 80 < 110 < A MC160TMR < 90 < 125 < A MC200TMR < 110 < 150 < A MC250TMR < 160 < 220 < A MC315T < 200 < 270 < A MC400T < 250 < 340 < A MC500T < 315 < 430 < A MC630T Moulded case circuit breakers are commonly applied to capacitor currents. However, due to high in-rush currents and harmonic content found in capacitor circuits, MCCBs should be rated > 1.5 times the current rating of the capacitor. MCCB Protection of Capacitor Circuits It is recommended that the MCCB should be utilized as a main isolation/protection device to the capacitor bank. (i.e. occasional switching). Capacitors should be individually protected and switched by appropriately rated contactors. 86

89 Technical Information IEC/EN is an international set of test specification standards for classifying the degrees of protection provided by the enclosures of electrical equipment against the intrusion into the equipment of foreign bodies (i.e. tools, dust, fingers, etc) and moisture. This classification system utilizes the letters IP ( Ingress Protection ) followed by two or three digits. (A third digit is sometimes used. An x is used for one of the digits if there is only one class of protection; i.e. IPX4 which addresses moisture resistance only.) Ingress Protection (IP Rating) The first digit of the IP code indicates the degree that persons are protected against contact with moving parts (other than smooth rotating shafts, etc.) and the degree that equipment is protected against solid foreign bodies intruding into an enclosure. The second digit indicates the degree of protection of the equipment inside the enclosure against the harmful entry of various forms of moisture (e.g. dripping, spraying, submersion, etc.) [For full details consult IEC/EN60529] PROTEUS 1st Digit Protection from solid objects 2nd Digit Protection from moisture 1 Protected against solid object greater than 1 Protection against vertically dripping water 50mm 2 Protected against solid object greater than 12.5mm 3 Protected against solid object greater than 2.5mm 4 Protected against solid object greater than 1mm 2 Protection against dripping water when tilted upto 15degrees 3 Protection against spraying water 4 Protection against splashing water 5 Dust protected 5 Protection against jetting water 6 Dust tight 6 Protection against powerfully jetting water 7 Protection against the temporary affects of immersion 8 Protection against continuous submersion Standard BS88 BSEN60269 BSEN61439 BSEN BSEN BSEN60529 BSEN60898 BSEN60947 BSEN BSEN BSEN BSEN61008 BSEN61009 BSEN61095 Applicable Standards Though not exhaustive the below table lists the British / European harmonised standards to which products in this catalogue comply (where applicable). Title Cartridge fuses for voltages up to and including 1000A a.c. and 1500V d.c. Low-voltage Fuses Low-voltage switchgear and controlgear assemblies Power switchgear and controlgear assemblies Distribution boards intended to be operated by ordinary persons (DBO) Specification for degree of protection provided by enclosures (IP code) Specification for circuit-breakers for overcurrent protection for household and similar installations Low-voltage switchgear and control gear Circuit-breakers Switches, disconnectors, switch-disconnectors and fuse-combination units Electromechanical contactors and motor starters Residual current operated circuit breakers without integral overcurrent protection for household and similar use (RCCBs / RCDs) Residual current operated circuit breakers with integral overcurrent protection for household and similar use (RCBOs) Specification for electromechanical contactors for household and similar purposes Technical Information 87

90 88 Index Index 1SCT SCT/P MBRSP MBRSPK MCRSP MCRSPK MRBE MBRSP MBRSPK MCRSP MCRSPK MRBE MBRSP MBRSPK MCRSP MCRSPK MRBE MBRSP MBRSPK MCRSP MCRSPK MRBE /2/30T /2/100T /2/300T /2/500T /4/30* /4/ /4/ MBRSPK MCRSPK MBRSP MBRSPK MCRSP MCRSPK MRBE /2/30T /2/100T /2/300T /2/500T /4/ /4/ /4/ MBRSP MCRSP MRBE MBRSP MBRSPK MCRSP MCRSPK S S /2/30T /2/100T /2/300T /2/500T /4/ /4/ /4/ S S S MBRSP MCRSP ST ST /2/30T /2/100T /2/300T /2/500T /4/ /4/ /4/ /2/30T /2/100D /2/100T /2/300T /2/500T /4/30* /4/ /4/ BC BC BC BC S S S MBRSP MCRSP MBRSP MCRSP BC BC BC BC MBRSP MCRSP S SQ S SQ BC BC BC BC MBRSP MCRSP BC BC BC BC MBRSP MCRSP BC BC BC BC B B B B C B C B C B C B C FS B C B C B B C B C BC BC BC FS / / / / / / / / / / / / / / / / /4...49

91 89 PROTEUS Index Index 1063/ / C C C C C C C C C / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / A ABX2R30V...32 ABX2R100V...32 ABX2R300V...32 ABX2S ABX2S1V...32 ABX4R30V...32 ABX4R100V...32 ABX4R300V...32 ABX4S ABX4S1V...32 ABX6R30V...32 ABX6R100V...32 ABX6R300V...32 ABX6S ABX6S1V...32 ABX8R30V...32 ABX8R100V...32 ABX8R300V...32 ABX8S ABX8S1V...32 ABX12R30V...32 ABX12R100V...32 ABX12R300V...32 ABX12S ABX12S1V...32 AJBXM2U...61 AJBXM AJBXM4U...61 AJBXM AJBXM6U...61 AJBXM AJBXM8U...61 AJBXM AJBXM12U...61 AKBXM2U...61 AKBXM AKBXM4U...61 AKBXM AKBXM6U...61 AKBXM AKBXM8U...61 AKBXM AKBXM12U...61 AKL...65 ALBXM2U...61 ALBXM ALBXM4U...61 ALBXM ALBXM6U...61 ALBXM ALBXM8U...61 ALBXM ALBXM12U...61 APGU2M...64 APGU4M...64 APGU4MU...64 APSU95M...64 APSU115M...64 APXLM6U...64 APXLM10U...64 APXLM12U...64 APXLM16U...64 APXLM18U...64 APXLM22U...64 APXLM28U...64 ASM ASM ASM ASM ASM ASM AX AX4MA...33 AX4MD...33 AX AX AX8MA...33 AX8MD...33 AX AX12MA...33 AX12MD...33 AX AX AX AYXLM1JB2JB AYXLM1JB2JB3U...63 AYXLM AYXLM2JB4JB AYXLM2JB4JB4U...63 AYXLM2JB5JB AYXLM2JB5JB5U...63 AYXLM2JB6JB AYXLM2JB6JB6U...63 AYXLM AYXLM4KB8KB AYXLM4KB8KB8U...63 AYXLM4U...60 AYXLM AYXLM6U...60 AYXLM6Y2U...63 AYXLM AYXLM8U...60 AYXLM8Y4U...63 AYXLM8Y6U...63 AYXLM AYXLM10U...60 AYXLM10Y4U...63

92 90 Index Index AYXLM10Y10U...63 AYXLM AYXLM12U...60 AYXLM12Y4U...63 AYXLM12Y6U...63 AYXLM AYXLM14U...60 AYXLM AYXLM16U...60 AYXLM AYXLM18U...60 AYXLM AYXLM20U...60 AYXLM AYXLM26U...60 AYXLM30*...60 AYXLMDSLV AYXLMDSLV6U...63 AYXLMDSLV AYXLMDSLV10U...63 AYXLMDSLV AYXLMDSLV12U...63 AYXLMDSLV AYXLMDSLV16U...63 AYXLMDSLV AYXLMDSLV22U...63 AYXLME AYXLME AYXLME AYXLME AYXLME AYXLME AYXLME AYXLMJB3JB AYXLMJB3JB3U...62 AYXLMJB3JB3Y2U...63 AYXLMJB4JB4Y4U...63 AYXLMJB5JB AYXLMJB5JB5U...62 AYXLMJB5JB5Y4U...63 AYXLMJB6JB AYXLMJB6JB6U...62 AYXLMJB8JB AYXLMJB8JB8U...62 AYXLMJB10JB AYXLMJB10JB10U...62 AYXLMKB5KB AYXLMKB5KB5U...62 AYXLMKB6KB AYXLMKB6KB6U...62 AYXLMKB8KB AYXLMKB8KB8U...62 AYXLMKB10KB AYXLMKB10KB10U...62 AYXLMSLV AYXLMSLV6U...62 AYXLMSLV AYXLMSLV12U...62 B B BBS BCC185/ BCC185/ BCC240/ BLC6/ BLC6/ BLC8/ BLC8/ BLC10/ BLC10/ BM BX4P BX4Q BX4R BX4R BX4R , 30 BX4S BX4S BX4S125TNS...53 BX4S125TT...53 BX6P BX6Q BX6R BX6R BX6R , 30 BX6S BX6S BX6S125TNS...53 BX6S125TT...53 BX8P BX8Q BX8R BX8R BX8R BX8S BX8S BX8S125TNS...53 BX8S125TT...53 BX8S BX12P BX12Q BX12R BX12R BX12R BX12S BX12S BX12S125TNS...53 BX12S125TT...53 BX12S BX16P BX16Q BX16R BX16R BX16R BX16S BX16S BX16S125TNS...53 BX16S125TT...53 BX16S BX20P BX20Q BX20R BX20R BX20R BX20S BX20S BX20S125TNS...53 BX20S125TT...53 BX20S BX24P BX24Q BX24R BX24R BX24R BX24S BX24S BX24S125TNS...53 BX24S125TT...53 BX24S BXM BXM BXS2TNSK...53 BXS2TTK...53 BXSB BXSB BXSCK BXSCK C CB7TP...78 CB8DP...78 CB12DP...78 CB12TP...78 CB19SP...78 CB28SP...78 CB080S/C...25 CB080T/C...25 CB100S/C...25 CB100T/C...25 CB125S/C...25 CB125T/C...25

93 91 PROTEUS Index Index CBC CBCT CBENCSP...25 CBENCTP...25 CBX22I , 25 CBX22/I CBX24I , 25 CBX24/I CBX42I , 25 CBX42/I CBX44I , 25 CBX44/I CBX62I , 25 CBX62/I CBX64I , 25 CBX64/I CBX82I , 25 CBX82/I CBX84I , 25 CBX84/I CBX122I , 25 CBX122/I CBX124I , 25 CBX124/I CO/ CO/ CO/ CO/ CO/ CO/ CO/ CO/ CO/ CO/ CO/ CO/ CT CT202NC...77 CT CT204NC...77 CT CT404NC...77 CT CT634NC...77 D DLPX DLPX1P...78 E E20TN...39 E32TN...39 E63TN...39 E100TN...39 E160TN...39 E200TN...39 EF20D...39 EF20S...39 EF20TN...39 EF32D...39 EF32S...39 EF32TN...39 EF63D...39 EF63S...39 EF63TN...39 EF100D...39 EF100S...39 EF100TN...39 EHC EHC1L...72 EHC EMCB1NC...47 EMCB1NO...47 EMIS2 ECO...72 EMIS4 ECO...72 EMIS ECO...72 EMISN...72 EM/STOP...47 ENC ENC ENC ENC ENC ENC ENC ENC ENC ENC ENC ENC ENC ETB ETB5BL...72 ETB5BR...72 F FS G GBX GBX GBX GBX H HBX HBX HBX HBX HBX HLC HLC HLC HLC HLC I IP65E IP65E IP65E IP65E IP65E J JBX JBX JBX JBX JBX JBX JBX JBX K KBX KBX KBX KBX KBX KWH2A...27 KWH2D...27 KWH2E...27 KWH4A...27 KWH4D...27 KWH4E...27 KWH45AMID...72 KWH100AMID...72 L LBX LBX LBX LBX

94 92 Index Index M M20T...40 M25T...40 M32T...40 M63T...40 M100T...40 M160T...40 M200T...40 M M M M M M M M M M M M MC016S...22 MC016T...22 MC020S...22 MC020T...22 MC025S...22 MC025T...22 MC032S...22 MC032T...22 MC040S...22 MC040T...22 MC050S...22 MC050T...22 MC063FA...23 MC063S...22 MC063T...22 MC080S...22 MC080T...22 MC100F...23 MC100FA...23 MC100S...22 MC100T...22 MC125F...23 MC125FA...23 MC125S...22 MC125T...22 MC160F...23 MC160FA...23 MC160S...22 MC160T...22 MC200F...23 MC200FA...23 MC200S...22 MC200T...22 MC200TNA...23 MC250F...23 MC250FA...23 MC250FALF...23 MC250FLF...23 MC250T...22 MC250TLF...22 MC250TNA...23 MC315F...23 MC315FA...23 MC315T...22 MC400F...23 MC400FA...23 MC400T...22 MC400TNA...23 MC500F...23 MC500FA...23 MC500T...22 MC630F...23 MC630FA...23 MC630T...22 MC630TNA...23 MC800F...23 MC800T...22 MC800TNA...23 MC1000T...22 MC1250T...22 MC1600T...22 MCCBM MCE063F...17 MCE063T...17 MCE080F...17 MCE080T...17 MCE100F...17 MCE100T...17 MCE125F...17 MCE125T...17 MCE160F...17 MCE160T...17 MCE200F...17 MCE200T...17 MCE250F...17 MCE250T...17 MCE315F...17 MCE315T...17 MCE400F...17 MCE400T...17 MCE500F...17 MCE500T...17 MCE630F...17 MCE630T...17 MCE800F...17 MCE800T...17 MCEL100T...17 MCEL125T...17 MCEL160T...17 MCEL200T...17 MCEL250T...17 MCEL315T...17 MCEL400T...17 MCEL500T...17 MCEL630T...17 MCENC MCENC1F...18 MCENC MCENC2F...18 MCENC MCENC6F...18 MCENC MCENC8F...18 MCLK MCLK MCLK MCLTS...19 MCNUTM MCP32/I MCP32/I MCP42/I200F...10 MCP42/I250F...10 MCP44/I MCP44/I315F...12 MCP44/I MCP44/I400F...12 MCP48/I MCP48/I500F...14 MCP48/I MCP48/I630F...14 MCP48/I MCP48/I800F...14 MCP52/I MCP52/I MCP62/I200F...10 MCP62/I250F...10 MCP64/I MCP64/I315F...12 MCP64/I MCP64/I400F...12 MCP68/I MCP68/I500F...14 MCP68/I MCP68/I630F...14 MCP68/I MCP68/I800F...14 MCP72/I MCP72/I MCP82/I200F...10 MCP82/I250F...10 MCP84/I MCP84/I315F...12

95 Index MCP84/I MCP84/I400F...12 MCP88/I MCP88/I500F...14 MCP88/I MCP88/I630F...14 MCP88/I MCP88/I800F...14 MCP112/I MCP112/I MCP122/I200F...10 MCP122/I250F...10 MCP124/I MCP124/I315F...12 MCP124/I MCP124/I400F...12 MCP128/I MCP128/I500F...14 MCP128/I MCP128/I630F...14 MCP128/I MCP128/I800F...14 MCP152/I MCP152/I MCP162/I200F...10 MCP162/I250F...10 MCP164/I MCP164/I315F...12 MCP164/I MCP164/I400F...12 MCP168/I MCP168/I500F...14 MCP168/I MCP168/I630F...14 MCP168/I MCP168/I800F...14 MCP172/I MCP172/I MCP182/I200F...10 MCP182/I250F...10 MCP184/I MCP184/I315F...12 MCP184/I MCP184/I400F...12 MCP188/I MCP188/I500F...14 MCP188/I MCP188/I630F...14 MCP188/I MCP188/I800F...14 MCPBEB , 13, 15 MCPBEB , 13, 15 MCPCB22L...11, 13, 15 MCPCB22R...11, 13, 15 MCPCB24L...11, 13, 15 MCPCB24R...11, 13, 15 MCPCB32L...11, 13, 15 MCPCB32R...11, 13, 15 MCPCB34L...11, 13, 15 MCPCB34R...11, 13, 15 MCPD...19 MCPDMM063S...16 MCPDMM063T...16 MCPDMM100S...16 MCPDMM100T...16 MCPDMM125S...16 MCPDMM125T...16 MCPDMM160S...16 MCPDMM160T...16 MCPDMM200S...16 MCPDMM200T...16 MCPDMM250T...16 MCPDMM315T...16 MCPDMM400T...16 MCPDMM500T...16 MCPDMM630T...16 MCPDMM800T...16 MCPEB32L...11 MCPEB32R...11 MCPEB42FL...11 MCPEB42FR...11 MCPEB44L...13 MCPEB44R...13 MCPEB48R...15 MCPEB52L...11 MCPEB52R...11 MCPEB62FL...11 MCPEB62FR...11 MCPEB64L...13 MCPEB64R...13 MCPEB68R...15 MCPEB72L...11 MCPEB72R...11 MCPEB82FL...11 MCPEB82FR...11 MCPEB84L...13 MCPEB84R...13 MCPEB88R...15 MCPEB112L...11 MCPEB112R...11 MCPEB122FL...11 MCPEB122FR...11 MCPEB124L...13 MCPEB124R...13 MCPEB128R...15 MCPEB152L...11 MCPEB152R...11 MCPEB162FL...11 MCPEB162FR...11 MCPEB164L...13 MCPEB164R...13 MCPEB168R...15 MCPEB172L...11 MCPEB172R...11 MCPEB182FL...11 MCPEB182FR...11 MCPEB184L...13 MCPEB184R...13 MCPEB188L...15 MCPEB188R...15 MCPEL MCPEL MCPEL MCPEL MCPEL MCPEL MCPEL MCPID...19 MCPKWH063S...16 MCPKWH063SMID...16 MCPKWH063T...16 MCPKWH063TMID...16 MCPKWH100S...16 MCPKWH100SMID...16 MCPKWH100T...16 MCPKWH100TMID...16 MCPKWH125S...16 MCPKWH125SMID...16 MCPKWH125T...16 MCPKWH125TMID...16 MCPKWH160S...16 MCPKWH160SMID...16 MCPKWH160T...16 MCPKWH160TMID...16 MCPKWH200S...16 MCPKWH200SMID...16 MCPKWH200T...16 MCPKWH200TMID...16 MCPKWH250T...16 MCPKWH250TMID...16 MCPKWH315TMID...16 MCPKWH400TMID...16 MCPKWH500TMID...16 MCPKWH630TMID...16 MCPKWH800TMID...16 MCPMB32L...11 MCPMB32R...11 MCPMB42FL...11 MCPMB42FR...11 MCPMB44L...13 MCPMB44R...13 MCPMB48L...15 Index PROTEUS 93

96 94 Index Index MCPMB48R...15 MCPMB52L...11 MCPMB52R...11 MCPMB62FL...11 MCPMB62FR...11 MCPMB64L...13 MCPMB64R...13 MCPMB68L...15 MCPMB68R...15 MCPMB72L...11 MCPMB72R...11 MCPMB82FL...11 MCPMB82FR...11 MCPMB84L...13 MCPMB84R...13 MCPMB88L...15 MCPMB88R...15 MCPMB112L...11 MCPMB112R...11 MCPMB122FL...11 MCPMB122FR...11 MCPMB124L...13 MCPMB124R...13 MCPMB128L...15 MCPMB128R...15 MCPMB152L...11 MCPMB152R...11 MCPMB162FL...11 MCPMB162FR...11 MCPMB164L...13 MCPMB164R...13 MCPMB168L...15 MCPMB168R...15 MCPMB172L...11 MCPMB172R...11 MCPMB182FL...11 MCPMB182FR...11 MCPMB184L...13 MCPMB184R...13 MCPMB188L...15 MCPMB188R...15 MCPMFM315T...16 MCPMFM400T...16 MCPMFM500T...16 MCPMFM630T...16 MCPMFM800T...16 MCPT2/TNSIF...18 MCPT2/TTIF...18 MCPT12/TNS...18 MCPT12/TNSIF...18 MCPT12/TT...18 MCPT12/TTIF...18 MCST3P MCST3P MCST3P MCST4P MCST4P MCST4P MCST4P MCX22/I MCX22/I MCX24/I MCX24/I MCX42/I MCX42/I MCX44/I MCX44/I MCX62/I MCX62/I MCX64/I MCX64/I MCX82/I MCX82/I MCX84/I MCX84/I MCX122/I MCX122/I MCX124/I MCX124/I MEMI...47 MEMK...47 MEMSS...47 MEMT...47 MTGP32B...65 MTGP32P...65 MTGP40B...65 MTGP40P...65 MTGPR40/ P PC020230V...47 PC025230V...47 PC032230V...47 PC063230V...47 PC100230V...47 PC200230V...47 PCB1NC...47 PCB1NO...47 PCS PDU4S...34 PDU4S PDU4S2S...34 PDU4SS...34 PDU6S...34 PDU6S PDU6S2S...34 PDU6SS...34 PDU8S...34 PDU8S PDU8S2S...34 PDU8SS...34 PDU12S...34 PDU12S2S...34 PDU12SS...34 PDU16S...34 PDU16S2S...34 PDU16SS...34 PEB PEB4/ PEB PEB6/ PEB PEB8/ PEB PEB12/ PEBTL PEBTL6/ PEBTL PEBTL8/ PEBTL PEBTL12/ PES PES PES PES PES PMS PMS PMS PMS PMS PMS PMS PXL PXL PXL PXL PXL PXL PXL PXL PXS PXS PXS S SF SF SF SF SF SF

97 95 PROTEUS Index Index SF100/ SK2JB4JB SK3JB SK4JB SK5JB SK6JB SK7JB SKJB4JB SKJB5JB SKSLV6R SKSLV SPD/T1/TN...52 SPD/T1/TNE...52 SPD/T1/TT...52 SPD/T1/TTE...52 SPD/T2/SP...52 SPD/T2/SPE...52 SPD/T2/TN...52 SPD/T2/TNE...52 SPD/T2/TNS4P...52 SPD/T2/TNS4PE...52 SPD/T2/TNS4PEF...53 SPD/T2/TNS4PES...53 SPD/T2/TNS4PIF...52 SPD/T2/TT...52 SPD/T2/TT4P...52 SPD/T2/TT4PE...52 SPD/T2/TT4PEF...53 SPD/T2/TT4PES...53 SPD/T2/TT4PIF...52 SPD/T2/TTE...52 SPD/T3/LPC...52 SPD/T3/PC...52 SPD/T3/PCE...52 SPD/T3/SC...52 SPD/T3/SCE...52 SPD/T12/TNS4P...52 SPD/T12/TNS4PE...52 SPD/T12/TNS4PEF...53 SPD/T12/TNS4PES...53 SPD/T12/TNS4PIF...52 SPD/T12/TT4P...52 SPD/T12/TT4PE...52 SPD/T12/TT4PEF...53 SPD/T12/TT4PES...53 SPD/T12/TT4PIF...52 T TB TB TB TB TB TB TCO TCO TCO TCO TCO TCO TCO TCO TCO TCO TCO TCO TCO TCO TCO TCO TCO TCO TPS TPXIC TPXIC TPXIC TPXIC TPXIPC TPXIPC TPXIPC TPXIPC TPXMC TPXMC TPXMC TS20T...38 TS32T...38 TS63T...38 TS100T...38 TS125T...38 TS160T...38 TS200T...38 TSF20T...38 TSF32T...38 TSF63T...38 TSF100T...38 TSF160T...38 U U63FS...36 U63S...37 U100FS...36 U100S...37 U125FS...36 U125S...37 U160FS...36 U160S...37 U200FS...36 U200S...37 U250FS...36 U250S...37 U315FS...36 U315S...37 U400FS...36 U400S...37 U500FS...36 U500S...37 U630S...37 UCB UCB UCB W WFS63/IP WFS63/IP65SS...35 WFS100/IP WFS100/IP65SS...35 WFS125/IP WFS125/IP65SS...35 WFS160/IP WFS160/IP65SS...35 WFS200/IP WFS200/IP65SS...35 WSF20/IP WSF20/IP65SS...35 WSF32/IP WSF32/IP65SS...35 WSF63/IP WSF63/IP65SS...35 WSF100/IP WSF100/IP65SS...35 X XL4S1MA...27 XL4S1MD...27 XL4S XL4S XL4S125TNS...53 XL4S125TT...53 XL6BR...50 XL6CR...50 XL6S1MA...27 XL6S1MD...27 XL6S XL6S XL6S125TNS...53 XL6S125TT...53 XL8S1MA...27 XL8S1MD...27 XL8S XL8S XL8S125TNS...53

98 96 Index Index XL8S125TT...53 XL10BR...50 XL10CR...50 XL12S1MA...27 XL12S1MD...27 XL12S XL12S XL12S125TNS...53 XL12S125TT...53 XL16BR...50 XL16CR...50 XL16S1MA...27 XL16S1MD...27 XL16S XL16S XL16S125TNS...53 XL16S125TT...53 XL20BR...50 XL20CR...50 XL20S XL20S XL20S125TNS...53 XL20S125TT...53 XL24S XL24S XL24S125TNS...53 XL24S125TT...53 XL25CR...50 XL32BR...50 XL32CR...50 XL40BR...50 XL40CR...50 XL45BR...50 XL45CR...50 XL46MA...27 XL46MD...27 XL46SL...26 XL48SL...26 XL64SL...26 XL66SL...26 XL68MA...27 XL68MD...27 XL84SL...26 XL812MA...27 XL812MD...27 XLI XLI XLI XLKL...26, 30 XLS2TNSK...53 XLS2TTK...53 Y YXL YXL YXL YXL YXL YXL YXL YXL YXL YXL YXL YXL YXL

99 VISIT OUR WEBSITE ACCESS TO ALL OUR PRODUCTS. CATALOGUE & DATA SHEET DOWNLOADS. FOLLOW US ON SOCIAL MEDIA.

NEW Titan II A & B Distribution Boards

NEW Titan II A & B Distribution Boards A Type Board Specification: Powder Coated Epoxy Resin Finish RAL 7035 Designed and built in the UK to BS EN 60439 Maximum busbar rating 125A Degree of protection IP3X to BS EN 60529 Blank gland plates

More information

TP&N DISTRIBUTION BOARD TYPE B RANGE

TP&N DISTRIBUTION BOARD TYPE B RANGE GROUP Now included in the range: Extension Boxes Metering Kits Surge Suppression and more! TP&N DISTRIBUTION BOARD TYPE B RANGE A comprehensive distribution board range for modern commercial & industrial

More information

Dorman Smith Loadbank 125 MCCB Panel Boards

Dorman Smith Loadbank 125 MCCB Panel Boards Dorman Smith Loadbank 125 MCCB Panel Boards Section 3 MCCB Panel Boards Loadbank 125 Range (250A and 400A Ratings) Overview Key Features ASTA certified busbars with a short circuit rating of 25kA for 1

More information

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its Sentry 2 TECHNICAL HOTLINE +44 (0)268 563720 The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its environment. The curved lines and slim-line appearance

More information

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34 Memshield 3 MCB distribution boards and enclosures 2 Eaton s Memshield 3 MCB distribution boards have evolved through an intimate knowledge and feedback from electrical contractors, consulting engineers

More information

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A. www.moeller.co.uk MCCB Panel Boards 400A / 630A / 800A Product Catalogue and Selection Guide MCCB Panel Boards Moulded Case Circuit Breakers and Accessories XBoard Consumer Units XPole Miniature Circuit

More information

EUSR. An Introduction To BS7671 Amendment 3:2015 DESIGNED FOR featuring Consumer Units for Domestic (Household) Premises as per Reg

EUSR. An Introduction To BS7671 Amendment 3:2015 DESIGNED FOR featuring Consumer Units for Domestic (Household) Premises as per Reg PR EUSR An Introduction To BS7671 Amendment 3:2015 featuring Consumer Units for Domestic (Household) Premises as per Reg. 421.1.201 DESIGNED FOR 2015 Third Amendment Update Significant Change 3rd Amendment

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways.

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways. Doepke The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways. Designed to meet BSEN60439-3 these easy to install consumer units accept the

More information

LOADSTAR MCBs AND DISTRIBUTION BOARDS

LOADSTAR MCBs AND DISTRIBUTION BOARDS MCBS AND DISTRIBUTION BOARDS Devices 6kA and 10kA Ranges 6A to 63A Single, Double and Triple Pole Type B, C & D Single and Double module RCBOs 35mm 2 Cable Terminals BS EN 60898 System 125A and 250A TP

More information

RCCB

RCCB 2000 2000 is an advanced modular consumer unit system offering either DP isolator or 2 module DP RCCB (Residual Current Circuit Breaker) incoming control in a split load and inline arrangements. 236 Enclosures

More information

QUICK REFERENCE PRICE GUIDE JUNE 2016

QUICK REFERENCE PRICE GUIDE JUNE 2016 QUICK REFERENCE PRICE GUIDE JUNE 2016 OUR CUSTOMER CARE COMMITMENTS Quality is Guaranteed All products supplied from this Quick Price Guide carry a guarantee against defects in materials and workmanship

More information

Memguard Advantage DISTRIBUTION SYSTEM Product Guide. MCB Single Phase Distribution Boards MCB Three Phase Distribution Boards

Memguard Advantage DISTRIBUTION SYSTEM Product Guide. MCB Single Phase Distribution Boards MCB Three Phase Distribution Boards Memguard Advantage DISTRIBUTION SYSTEM Product Guide MCB Single Phase Distribution Boards MCB Three Phase Distribution Boards 1 Contents and Introduction Contents Page Introduction Contents and Introduction

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

Modis Ultra. LV Distribution System

Modis Ultra. LV Distribution System Modis Ultra LV Distribution System Dorman Smith Switchgear Limited With over 130 years of experience in switchgear design and production Dorman Smith Switchgear Limited continues to provide high quality

More information

Havells Switchgear. Trade Price List. PowerSafe - Commercial Range

Havells Switchgear. Trade Price List. PowerSafe - Commercial Range Havells Switchgear List PowerSafe - Commercial Range List Catalogue SPN Type A Distribution Boards PSA4 8906079 4 way 100A SPN Type A distribution board AA 53.73 PSA7 8906080 7 way 100A SPN Type A distribution

More information

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip Product Managers and dedicated Business Development Managers are available to assist with all your enquiries. Technical presentations (Forms of Separation, Discrimination etc) available Site response capability

More information

Talisman Plus. MCB Distribution Boards & Miniature Circuit Breakers BILL MEANS BUSINESS

Talisman Plus. MCB Distribution Boards & Miniature Circuit Breakers BILL MEANS BUSINESS Distribution Boards & Miniature Circuit Breakers BI MEANS BUSINESS A Type SPN Distribution Boards B Type TPN Distribution Boards A & B Type SPSN Distribution Boards Miniature Circuit Breakers 20V/15V AC

More information

TP&N Distribution Systems

TP&N Distribution Systems TP&N Distribution Systems Loadlimiter 63 Range TP&N Distribution Systems (B-type) O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E Dorman Smith Switchgear Ltd With over 130 years of

More information

Fuse Switch Panel Boards

Fuse Switch Panel Boards Fuse Switch Panel Boards Fuse Switch Panel Boards Loadbank 200 Range O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E Dorman Smith Switchgear Ltd With over 130 years of experience in

More information

Loadlimiter 63. MCB Distribution Boards

Loadlimiter 63. MCB Distribution Boards Loadlimiter 63 MCB Distribution Boards Dorman Smith Switchgear Limited With over 130 years of experience in switchgear design and production Dorman Smith Switchgear Limited continues to provide high quality

More information

References. References. Rating (A) Référence

References. References. Rating (A) Référence DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle

More information

O V E R Y E A R S O F E L E C T R I C A L E X C E L L E N C E

O V E R Y E A R S O F E L E C T R I C A L E X C E L L E N C E Over 130 Years of Electrical Excellence LV Switchboards up to 3200A Panel Boards 400-1250A L2 Compliant Distribution Boards Dorman Smith Switchgear Ltd With over 130 years of experience in switchgear design

More information

Smart solutions for electrical distribution in commercial and industrial applications

Smart solutions for electrical distribution in commercial and industrial applications Power distribution components MCB Distribution boards and enclosures MCCB Panelboards Switch and protection devices Industrial switch and fusegear Enclosed motor, heating and lighting control HRC cartridge

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

Smart solutions for electrical distribution in commercial buildings

Smart solutions for electrical distribution in commercial buildings MEM Sub-Distribution Solutions MCB single phase distribution boards MCB three phase distribution boards MCCB Panelboards Switch and Protection Devices Control and Switching Devices Metering Solutions Smart

More information

Smart solutions for electrical distribution in commercial buildings

Smart solutions for electrical distribution in commercial buildings Sub-distribution solutions MEM series MCB single phase distribution boards MCB three phase distribution boards MCCB Panelboards Switch and protection devices Control and switching devices Metering solutions

More information

Dorman Smith Switchgear Product Portfolio

Dorman Smith Switchgear Product Portfolio Dorman Smith Switchgear Product Portfolio How to use this catalogue This catalogue has been designed to enable users to access the information on the whole product range in a straight-forward and logical

More information

Sentry. Flush mounting versions Flush mounting available for even neater installations.

Sentry. Flush mounting versions Flush mounting available for even neater installations. 271 range introduction features and benefits The range of Consumer Units from MK Electric has been stylishly designed to blend in with its environment. The curved lines and slim-line appearance mean it

More information

Pan assemblies and installation accessories

Pan assemblies and installation accessories Contents Section 10 Pan assemblies and installation accessories SP&N pan assemblies 124 SP&N door and cover 124 TP&N pan assemblies 125 TP&N door and cover 125 Multiclip busbar and Polybloc 126 Comb busbars

More information

LoadCentre KQ+ Distribution boards

LoadCentre KQ+ Distribution boards LoadCentre KQ+ Distribution boards Simply safer Square D Serving Your Needs To help electrical contractors Square D provide: An extensive range of easy to install products. Readily available products from

More information

Technical data Consumer units and enclosures dimensions and data 12.4

Technical data Consumer units and enclosures dimensions and data 12.4 d w h Isolator controlled surface mounting consumer units EAD1 98 153 94 EAD2/3 154 223 101 EAD4 235 223 120 EAD6 271 223 120 EAD8 307 223 120 EAD12 379 223 120 EAD16 450 223 120 EAD19 450 223 120 Note:

More information

Invicta 3 Panelboards

Invicta 3 Panelboards Invicta 3 Panelboards The new range of Invicta 3 panelboards are our easiest boards ever to install, and will help you meet the needs of Part L2 of the Building Regulations. The last few years have seen

More information

Defender B Board. Make The Switch

Defender B Board. Make The Switch Defender B Board Make The Switch Defender B Board 1.2mm Electro Galvanised Sheet Steel Tested to BS EN61439-3 Busbar Short Time Withstand Rating Icw 20kA 0.25s Tested at 35 C Ambient Tin Plated Busbar,

More information

the Santon FCS-type switch Disconnect Superior Switch Solutions

the Santon FCS-type switch Disconnect Superior Switch Solutions the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

Defender 1.0. Consumer Units & Devices Domestic Household Premises

Defender 1.0. Consumer Units & Devices Domestic Household Premises Defender 1.0 Consumer Units & Devices Domestic Household Premises Defender 1.0 Contactum Metal Consumer Units for Domestic Hous In January 2015 IET published Amendment 3 of the Wiring Regulations BS7671.

More information

Protect Circuit Protection

Protect Circuit Protection Circuit Protection Product Catalogue 2018 Protect Circuit Protection Deta s new range of domestic Circuit Protection provides a high quality and cost effective solution, perfect for both new build and

More information

Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time

Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time Catalogue G System Pack, wall mount and floor standing enclosures Prisma Plus LV Switchboards Devised to save time General contents Index 2 General presentation 8 Pack 10 17 General presentation Installation

More information

Consumer Units IP Rated & Metal Enclosures Devices - MCBs, RCBOs & RCDs. Control Devices & Accessories

Consumer Units IP Rated & Metal Enclosures Devices - MCBs, RCBOs & RCDs. Control Devices & Accessories Consumer Units IP Rated & Metal Enclosures Devices MCBs, RCBOs & RCDs Control Devices & Accessories Modern stylish design with a profile that matches Nexus wiring accessories Quality designed in Flexibility

More information

L.V. Systems & Solutions

L.V. Systems & Solutions GE Energy Industrial Solutions L.V. Systems & Solutions Residential Components & Distribution Boards Home & Building Automation Industrial Breakers General Purpose Enclosures System Enclosures Control

More information

ßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards

ßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards CHINT EUROPE (UK) LTD Chint Metal Consumer Units ßCompliant with Amendment 3 of BS 7671 : 2008 Regulation 421.1.201 ßBSEN 61439-3 3 to 36 Ways are Standard Specials to Customer Requirements ß 1mm steel

More information

XL 4000 metal free-standing enclosures and cable compartments

XL 4000 metal free-standing enclosures and cable compartments 87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL metal free-standing enclosures and CONTENTS PAGE 1. General characteristics...1 2. Range...2 3. Overall dimensions...2 4. Equipment...3

More information

Powerpact 4 panelboards Panelboards and incoming devices Panelboards

Powerpact 4 panelboards Panelboards and incoming devices Panelboards Panelboards and incoming devices Panelboards Panelboards MG25C2 250A 13 way powerboard 506.76 MG25C4 250A 17 way powerboard 534.00 MG2C5 250A 5 way panelboard 620.33 MG2C7 250A 7 way panelboard 650.83

More information

Memshield 3 panelboards and associated devices. Cross-reference & price guide

Memshield 3 panelboards and associated devices. Cross-reference & price guide Memshield 3 panelboards and associated devices Cross-reference & price guide Effective 1st November 2011 Frequently Asked Questions Question 1 When will the new range be available for sale? Answer Memshield

More information

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2 The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results

More information

Defender 1.0. Consumer Units & Devices Domestic Household Premises

Defender 1.0. Consumer Units & Devices Domestic Household Premises Defender 1.0 Consumer Units & Devices Domestic Household Premises Defender 1.0 Contactum Metal Consumer Units for Domestic Hous In January 2015 IET published Amendment 3 of the Wiring Regulations BS7671.

More information

B60 Domestic Voltage Optimisation Unit

B60 Domestic Voltage Optimisation Unit B60 Domestic Voltage Optimisation Unit Installation Manual V1.2 Nov 2013 1 P a g e PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with the IEE Wiring Regulations,

More information

Commercial Circuit Protection

Commercial Circuit Protection Commercial Circuit Protection Acknowledged as one the leading brands in the UK and in British Standard markets around the world, Crabtree offers designers & specifiers a wide range of quality products

More information

Defender. Consumer Units & Devices Domestic Household Premises

Defender. Consumer Units & Devices Domestic Household Premises Defender Consumer Units & Devices Domestic Household Premises Defender Contactum Metal Consumer Units for Domestic Hous In January 2015 IET published Amendment 3 of the Wiring Regulations BS7671. The changes

More information

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by

More information

The right solution for every home

The right solution for every home Domae Household switchboards The right solution for every home Household guide 2002 Building a New Electric World. Household switchboards Domae The right solution for every home Household guide 2002 Building

More information

Enclosures & Rotary Switches

Enclosures & Rotary Switches Enclosures & Rotary Switches Circular Box with Cable Glands Junction box with plain press on lid IP44 10 + GW 44001 65mm x 35mm depth 1.00 0.90 GW 44002 80mm x 40mm depth 1.20 1.00 Transparent Cover Boxes

More information

Common Departures Interconnecting Facilities Requirements

Common Departures Interconnecting Facilities Requirements Welcome to our e-rew Express. In our last issue, we discussed the common departures on metering installation requirements. This time, we would like to discuss the common departures on the customer low

More information

phone fax post web ordering information Please call for the latest pricing or to request a free price list.

phone fax post  web ordering information Please call for the latest pricing or to request a free price list. switchgear everything for those switched on phone fax post email web ordering information Please call for the latest pricing or to request a free price list. opening an account To open a 30 day credit

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS 2 ENERGY /// TE'S CROMPTON INSTRUMENTS 3 Table of contents I. Tape Wound Measuring and Protection Current MR Series Measuring

More information

PDI Modular Compact Remote Power Panel

PDI Modular Compact Remote Power Panel Guide Specifications (Revision 000, 6/17/2016) 1 GENERAL 1.1 Summary These specifications describe requirements for a remote power panel (RPP) distributing power to sensitive loads. These specifications

More information

B60 Domestic Voltage Optimisation Unit. Installation Manual

B60 Domestic Voltage Optimisation Unit. Installation Manual Govna B60PVM Voltage Optimisation Unit Govna B60PVM Voltage Optimisation Unit B60 Domestic Voltage Optimisation Unit Web: www.renewableenergyhub.co.uk Email: info@renewableenergyhub.co.uk Phone: 0845 862

More information

Starbreaker Consumer Units & Devices

Starbreaker Consumer Units & Devices Starbreaker Consumer Units & Devices Acknowledged as one the leading brands in the UK and in British Standard markets around the world, Crabtree offers designers & specifiers a wide range of quality products

More information

SPM Series Plug-in Surge Protection

SPM Series Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

Residential circuit protection buyers guide

Residential circuit protection buyers guide Residential circuit protection buyers guide 2 Contents The range overview... 4 Wiring regulation changes... 6 Domae consumer units... 8 Features and benefits... 9 Quick selector - reference numbers and

More information

PRODUCTCATALOGUE. LV Switchgear Distribution Boards Consumer Units Circuit Protection Devices

PRODUCTCATALOGUE. LV Switchgear Distribution Boards Consumer Units Circuit Protection Devices PRODUCTCATALOGUE LV Switchgear Distribution Boards Consumer Units Circuit Protection Devices Installation Materials Division...the name behind the brands Content 230V Switchgear Metalclad Consumer Units...58

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

US Catalog July 2016 SMISSLINE TP

US Catalog July 2016 SMISSLINE TP US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information

More information

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its Sentry 2 TECHNICAL HOTLINE +44 (0)268 563720 The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its environment. The curved lines and slim-line appearance

More information

Domae and Qwikline ll. Consumer units

Domae and Qwikline ll. Consumer units Domae and Qwikline ll Consumer units Features and benefits Contents The range overview 3 Domae consumer units 4 Features and benefits 5 Quick selector - reference numbers & descriptions 6 Consumer unit

More information

SIRCO Load break switches for power distribution from 125 to 5000 A

SIRCO Load break switches for power distribution from 125 to 5000 A The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct

More information

CABINETS & ENCLOSURES FOR PREPAYMENT METERS

CABINETS & ENCLOSURES FOR PREPAYMENT METERS CABINETS & ENCLOSURES FOR PREPAYMENT METERS Solutions designed according to customer need, conceived for every type of prepayment meter: > Meters with keypad data entry terminal > Split meters with remote

More information

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

LSFC Power Factor Correction Systems

LSFC Power Factor Correction Systems LSFC Ready to connect, automatic in sheet steel cabinets for floor installation. Suitable for networks without harmonic distortion. Power Range: 100 to 00 kvar Modular construction in freestanding sheet

More information

CONTROL PANEL WIRING SPECIFICATIONS

CONTROL PANEL WIRING SPECIFICATIONS CONTROL PANEL WIRING ISSUE STATUS FIRST REV DESCRIPTION DATE 001 1 ST ISSUE 22/04/2014 002 1 ST AMMENDMENT 10/03/2017 003 2 ND AMMENDMENT 08/09/2017 THIS DOCUMENT IS DESIGNED TO COVER ALL APPLICATIONS,

More information

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

I-Line Panelboards. Innovative design, smart bus technology, and simple installation I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted

More information

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb_cat Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle Direct handle acces_147_a_2_cat

More information

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual Installation Manual V2.2 November 2015 PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with the IEE Wiring Regulations, BS7671 (17th Edition or later) and current

More information

Power-Style QED-2, Series 2 Low Voltage Switchboards

Power-Style QED-2, Series 2 Low Voltage Switchboards Power-Style QED-2, Series 2 Low Voltage Switchboards Catalog 2742CT1001 (Addendum to 2742CT9501R12/09) 2010 Class 2742 CONTENTS Description............................................. Page Features...................................................

More information

Featuring Spectra RMS Breakers

Featuring Spectra RMS Breakers 8000-Line Motor Control Centers Featuring Spectra RMS Breakers Fully integrated capabilities make GE your complete motor control center supplier Order management Coordinated drawings Applications support

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

Sentry Technical. Consumer Units and Enclosures TD255. Standards and approvals. Description. Features. Technical specification

Sentry Technical. Consumer Units and Enclosures TD255. Standards and approvals. Description. Features. Technical specification TD255 Consumer Units and Enclosures Standards and approvals All Sentry consumer units are designed to fully comply with the requirements of BS EN 60439-3. Weatherproof enclosures are designed to fully

More information

Type B, TPN distribution boards 2.2

Type B, TPN distribution boards 2.2 M distribution boards and enclosures Type, N distribution boards 2.2 See page 8 for technical data and overall dimensions EM A/A N, type distribution boards Total no. of (A) outgoing ways 4 way N, type

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

Isobar 4c distribution boards and devices Selection guide

Isobar 4c distribution boards and devices Selection guide Isobar 4c distribution boards and devices Selection guide Isobar 4c Type A distribution boards Standard 125A distribution boards excluding incomer SP outgoing 6 MGAN6 9 MGAN9 12 MGAN12 15 MGAN15 23 MGAN23

More information

Zenith Series MDU & RDU. Critical Power Distribution Units

Zenith Series MDU & RDU. Critical Power Distribution Units Zenith Series MDU & RDU Critical Power Distribution Units Touching all Areas of the Energy Industry GE s diverse portfolio of products and services is helping customers solve problems every day. We touch

More information

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications Protection and Connection Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications DC switch-disconnectors

More information

TERASAKI ENGINEERING SPECIALISTS SINCE 1923

TERASAKI ENGINEERING SPECIALISTS SINCE 1923 Innovators in Protection Technology TERASAKI TERASAKI ENGINEERING SPECIALISTS SINCE 1923 The Terasaki Electric Company, Japan, was founded in 1923 in the industrial city of Osaka. In its early beginnings

More information

SPM Series. Plug-in Surge Protection

SPM Series. Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

Adaptors Busplug Low Voltage Switchboard Equipment

Adaptors Busplug Low Voltage Switchboard Equipment Busplug Adaptors Low Voltage Switchboard Equipment Publication BA 2012 CONTENTS Descriptive Advantages of Busplugs 2 General Description 3 Use of Busplugs Adaptors 3 Construction 4 Technical Standards

More information

Air-insulated medium-voltage secondary distribution switchgear

Air-insulated medium-voltage secondary distribution switchgear DISTRIBUTION SOLUTIONS Air-insulated medium-voltage secondary distribution switchgear Compact size Complete solution Factory tested Air-insulated medium-voltage secondary distribution switchgear The ABB

More information

Consumer Units - Metal

Consumer Units - Metal Circuit Protection Consumer Unit Glands 153 Consumer Units - Insulated 154-156 Consumer Units - Metal 148-151 Contactors 160 DIN Rail Enclosures 159 Fuses - Domestic 161 Fuses - Industrial 162-163 Locking

More information

MOTOR CONTROL CENTER INFINITY SERIES

MOTOR CONTROL CENTER INFINITY SERIES MOTOR CONTROL CENTER INFINITY SERIES Infinity in brief Panel & Building Solutions Meets latest UL, CSA and IEC standards, as well as ABS & DNV-GL international approvals Fully withdrawable Drawer Units

More information

GROUP. SMART SOLUTIONS FOR POWER DISTRIBUTION Industrial & Domestic. A handy guide to the Lewden everyday mainstream offer

GROUP. SMART SOLUTIONS FOR POWER DISTRIBUTION Industrial & Domestic. A handy guide to the Lewden everyday mainstream offer GROUP SMART SOLUTIONS FOR POWER DISTRIBUTION Industrial & Domestic A handy guide to the Lewden everyday mainstream offer From UK to UK Over 2,500 different products are at your disposal with a next day

More information

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection... .3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual

More information

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output

More information

Design Range of Consumer Units. Amendment 3 compliant

Design Range of Consumer Units. Amendment 3 compliant Design Range of Consumer Units Amendment 3 compliant March 2015 Designed for safety Designed for installation Designed for aesthetics by Design 10, 30 The amendment 3 Hager Design ranges include surface

More information

NOW AVAILABLE AT IP66 RATING. Fast Fit. 3 phase distribution boards. clipsal.com. Designed for easy installation and fast wiring

NOW AVAILABLE AT IP66 RATING. Fast Fit. 3 phase distribution boards. clipsal.com. Designed for easy installation and fast wiring NOW AVAILABLE AT IP66 RATING Fast Fit 3 phase distribution boards clipsal.com Designed for easy installation and fast wiring We ve opened our doors to commercial SERIES 4consumer switchboards The Clipsal

More information

Make the Switch. Your Specialist in CONTROL SOLUTIONS SPEEDY BUILD. AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (20A A)

Make the Switch. Your Specialist in CONTROL SOLUTIONS SPEEDY BUILD. AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (20A A) Make the Switch SPEEDY BUILD Rapid Run Service AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (0A - 150A) Your Specialist in CONTROL SOLUTIONS Contents 3. Surface Mounting IP65 Plastic

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

Design Range of Consumer Units. Amendment 3 compliant

Design Range of Consumer Units. Amendment 3 compliant Design Range of Consumer Units Amendment 3 compliant March 2015 Designed for safety Designed for installation Designed for aesthetics by Features Comparison Feature Square Knockouts Grommet Strips Front

More information