Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time

Size: px
Start display at page:

Download "Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time"

Transcription

1 Catalogue G System Pack, wall mount and floor standing enclosures Prisma Plus LV Switchboards Devised to save time

2 General contents Index 2 General presentation 8 Pack General presentation Installation and connection of units in the switchboard Installation and connection of units in the duct Choice of enclosure Distribution, connection, accessories Dimensions 133 Characteristics 145 1

3 Index Cat. no Pages Cat. no Pages M6 hexagonal spacers, H=23mm 55, 67, 117, M6 hexagonal spacers, H=55mm 55, 67, 117, M6 hexagonal spacers, H=25mm 55, M8 hexagonal spacers, H=40+10mm 55, Modular front plate, 2 modules Modular front plate, 3 modules 45, 48, 52, Modular front plate, 4 modules Modular front plate, 5 modules 13, 45, Modular front plate, 3 modules, W=250mm 62, Modular front plate, 4 modules, W=250mm Blanking strip, L=1000mm 15, 47, divisible blanking plates, W=90mm 15, 47, Front plate for horizontal fixed NS250 with toggle Front plate for horizontal INS Modular device rail 45, 48, 52, Adjustable modular device rail 35, 37, 39, 43, 45, 48, 54, Recessed modular device rail 39, 49, Rear modular device rail 13, 48, 49, 54, DIN rail support 117, Modular device rail for NSA in Pack enclosure Modular device rail, L=250mm 62, 64, Adjustable modular device rail, L=250mm 59, 61, 62, 64, 65, Mounting plate for horizontal fixed NS-INS250 with 34, 38 toggle Mounting plate for horizontal fixed NS250 with 36 rotary handle Mounting plate for horizontal fixed NS250 with 34, 36, 39 motor mechanism or horizontal plug-in NS250 with toggle Mounting plate for horizontal fixed Vigi NS250 with 34 toggle Mounting plate for vertical fixed NS250 with toggle 35, Mounting plate for vertical fixed NS250 with rotary 37 handle Mounting plate for NS-INS250 source changeover 40, 41 system with rotary handles Mounting plate for vertical fixed NS-INS250 with 58, 60 toggle, W=250mm Mounting plate for vertical fixed NS-INS250 with 58 rotary handle, W=250mm Mounting plate for horizontal fixed NS630 with 32, 38 toggle Mounting plate for vertical fixed NS-INS630 with 33, 39 toggle Mounting plate for vertical fixed NS630 with rotary 33 handle Mounting plate for vertical fixed NS-INS630 with 58, 60 toggle, W=250mm Mounting plate for vertical fixed NS-630 with rotary 58 handle, W=250mm Mounting plate for INF32/40 42, Mounting plate for INF , M4 clip-nuts for DIN rails 55, M5 clip-nuts for DIN rails 55, M6 clip-nuts for DIN rails 55, Mounting plate for Tego Power Slotted mounting plate, 4 modules, for wall-mount 54 or floor-standing enclosure Recessed slotted mounting plate, 4 modules, for 49, 54 wall-mount or floor-standing enclosure Recessed slotted mounting plate, 6 modules, for 13, 49, 54 wall-mount or floor-standing enclosure Recessed slotted mounting plate, 9 modules, for 54 wall-mount or floor-standing enclosure Slotted mounting plate, 4 modules, W=250mm 65, Recessed slotted mounting plate, 4 modules, 66 W=250mm Recessed slotted mounting plate, 6 modules, 66 W=250mm Recessed slotted mounting plate, 9 modules, 66 W=250mm M4 clip-nuts for slotted mounting plates 55, M5 clip-nuts for slotted mounting plates 55, M6 clip-nuts for slotted mounting plates 55, M5 self-tapping screws for functional unit 55, 67 mounting M5 hexagonal spacers, H=9mm 55, M5 hexagonal spacers, H=23mm 55, M5 hexagonal spacers, H=55mm 55, captive nuts for M6 hexagonal spacers 55, 67, M6 hexagonal spacers, H=9mm 55, 67, 117, Front plate for horizontal fixed NS250 with rotary 36 handle Front plate for horizontal plug-in NS250 with toggle Front plate for horizontal fixed NS250 with motor 36 mechanism Front plate for INS250 source changeover system 41 with rotary handles Front plate for horizontal fixed NS250 with toggle + 34 ammeter Front plate for horizontal fixed Vigi NS250 with 36 rotary handle Front plate for horizontal fixed Vigi NS250 with 34 toggle Front plate for 3-4 vertical Vigi NS250 devices with 35 toggles Front plate for 3-4 vertical NS250 devices 35, Front plate for 3-4 vertical Vigi NS250 devices with 37 rotary handles or motor mechanisms Front plate for vertical NS250 source changeover 40 system with rotary handles Front plate for INS250 complete source 41 changeover assembly Front plate for vertical INS Blanking plate for vertical NS-INS Front plate for vertical fixed NS250 with toggle, 58 W=250mm Front plate for vertical fixed INS250 with toggle, 60 W=250mm Front plate for vertical fixed Vigi NS250 with 58 toggle, W=250mm Front plate for vertical fixed NS250 with rotary 58 handle, W=250mm Front plate for horizontal fixed NS630 with toggle Front plate for horizontal INS Front plate for vertical NS630 with toggle Front plate for vertical INS Front plate for vertical NS630 with rotary handle or 33 motor mechanism Front plate for vertical Vigi NS630 with toggle Front plate for vertical Vigi NS630 with rotary 33 handle or motor mechanism Front plate for vertical fixed NS630 with toggle, 58 W=250mm Front plate for vertical fixed INS630 with toggle, 60 W=250mm Front plate for fixed Vigi NS630 with toggle, 58 W=250mm Front plate for vertical NS630 with rotary handle or 58 motor mechanism, W=250mm Front plate for vertical INF32/40, 3P Front plate for INF32/40, 4P and horizontal 3P 42, Front plate for INF63-160, 3P and vertical INV63, 42, 43 3P Front plate for vertical INF63, 4P and vertical 43 INF Transparent front plate, 4 modules 13, 48, Transparent front plate, 6 modules 49, Transparent front plate, 9 modules 56 2

4 Index Cat. no Pages Cat. no Pages Transparent front plate, 12 modules Multi-stage distribution block, 4P, 400A Transparent front plate, 4 modules,w=250mm 56, 64, Multi-stage distribution block, 4P, 630A Transparent front plate, 6 modules,w=250mm 56, Power supply block for horizontal NS250 34, 38, Transparent front plate, 9 modules,w=250mm 56, Universal power supply block, 250A 35, 36, 37, lead-sealable front plate screws , 59, 61, Plain front plate, 1 module 13, 33, 34, 35, 37, 38, 39, 48, Connection between vertical NS-INS250 and 35, 37, 39, 99 49, 56 universal power supply block Plain front plate, 2 modules 33, 34, 35, 36, Connection between vertical NS-INS250 in duct 59, 61, 99 37, 39, 40, 41, and universal power supply block 42, 43, Connection between vertical NS-INS250 in duct 59, Plain front plate, 3 modules 13, 32, 33, 38, and busbars 40, 48, 56, Incoming connection block for NS-INS250 34, Plain front plate, 4 modules 33, 49, 56 supplied via the top Plain front plate, 5 modules 49, 56, Incoming connection block for NS-INS250 34, 38 supplied via the bottom Plain front plate, 6 modules 39, 49, 56, Power supply block for horizontal NS400 32, 38, Plain front plate, 9 modules Power supply block for horizontal NS630 32, 38, Plain front plate, 12 modules Connection between vertical NS-INS in 59, 61, Plain front plate, 1 module, W=250mm 58, 62, 64, 68 duct and universal power supply block Plain front plate, 2 modules, W=250mm 58, 60, Universal power supply block, A 33, 39, 59, 61, Plain front plate, 3 modules, W=250mm 64, Plain front plate, 4 modules, W=250mm 65, Connection between vertical NS-INS630 in duct 59, Plain front plate, 5 modules, W=250mm 68 and busbars Plain front plate, 6 modules, W=250mm Plain front plate, 9 modules, W=250mm Front plate for fan or grill IP30 ventilated front plate, 1 module IP30 ventilated front plate, 3 modules Plain mounting plate for 72x72mm meter Plain mounting plate for 96x96mm meter Mounting plate with cut-out for 72x72mm meter Mounting plate with cut-out for 96x96mm meter Front plate with cut-outs for meter mounting plates Blanking plate, 72x72mm Blanking plate, 96x96mm, for meters Front plate with cut-outs for 72x72mm meters Front plate with cut-outs for 96x96mm meters 51, Front plate with cut-outs for 144x144mm x72mm meters Front plate with holes for 22mm dia. pushbuttons 51 and lamps Visor for human/switchboard interface (HSI) Front plate for Vigilohm TR22A+6 72x72mm 52 meters Multiclip distribution block, 4P, 80A, 1 row 14, 47, Multiclip distribution block, 4P, 63A, 1/2 row 14, 47, Multiclip distribution block, 2P, 200A, 1 row 47, Multiclip distribution block, 3P, 200A, 1 row 47, Multiclip distribution block, 4P, 200A, 1 row 47, Multiclip distribution block, 4P, 160A, 1/2 row 47, Powerclip busbar connection for 200A Multiclip 47, 99, 115 distribution block Duct busbar connection for 200A Multiclip 103, 115 distribution block Rear busbar connection for 200A Multiclip 101, 115 distribution block Polybloc distribution block, 1P, 160A 12, Polybloc distribution block, 3P, 250A 34, 35, 36, 37, 38, 39, 43, 59, 61, Polybloc distribution block, 4P, 250A 34, 35, 36, 37, 38, 39, 43, 59, 61, Cu spacers for Polybloc 250A distribution block Distribloc , 47, Distribloc 160+connections 12, 47, NG-INS125 connections for Distribloc Multi-stage distribution block, 4P, 160A Multi-stage distribution block, 4P, 250A In-duct incoming connection block for NS Powerclip busbars, 125A, 3P, L=450mm 12, Powerclip busbars, 125A, 4P, L=450mm 12, Powerclip busbars, 125A, 3P, L=750mm 12, Powerclip busbars, 125A, 4P, L=750mm 12, Powerclip busbars, 160A, 3P, L=1000mm 12, Powerclip busbars, 250A, 3P, L=1000mm Powerclip busbars, 400A, 3P, L=1000mm Powerclip busbars, 630A, 3P, L=1000mm Powerclip busbars, 160A, 3P, L=1400mm 12, Powerclip busbars, 250A, 3P, L=1400mm Powerclip busbars, 400A, 3P, L=1400mm Powerclip busbars, 630A, 3P, L=1400mm Powerclip busbars, 160A, 4P, L=1000mm 12, Powerclip busbars, 250A, 4P, L=1000mm Powerclip busbars, 400A, 4P, L=1000mm Powerclip busbars, 630A, 4P, L=1000mm Powerclip busbars, 160A, 4P, L=1400mm 12, Powerclip busbars, 250A, 4P, L=1400mm Powerclip busbars, 400A, 4P, L=1400mm Powerclip busbars, 630A, 4P, L=1400mm connections, 125A 12, 98, connections 160 A connections, 160A 12, IPxxB covers for Powerclip busbars 12, Powerclip tap-off blocks with 6mm² + 10mm² 12, 99 terminals Powerclip tap-off blocks with 16mm² terminals 12, Additional 35mm² block, 3P 99, Additional 35mm² block, 4P 99, screws for Powerclip busbars 12, bars with threaded holes, 160A, L=1000mm 101, bars with threaded holes, 250A, L=1000mm 101, bars with threaded holes, 400A, L=1000mm 101, bars with threaded holes, 160A, L=1400mm 101, bars with threaded holes, 250A, L=1400mm 101, bars with threaded holes, 400A, L=1400mm 101, bars with threaded holes, 630A, L=1400mm copper angle brackets, 250A Rear busbar support Multi-stage bar support for duct M6x20mm bolts for 5mm bars 101, M6x16mm screws for bars with threaded holes, 101, 103 less than 630A Busbar power supply barrier, 630A Rear busbar barrier 101 3

5 Index Cat. no Pages Cat. no Pages Earth bar, 24 modules 14, Transparent door for Pack enclosure, W=550mm, Earth bar for direct earth blocks, 12x3mm 14, rows earth bars, 12 modules supports for earth bar on DIN rail Fixing brackets for vertical earth bar in wall-mount or floor-standing enclosure, H=15mm Fixing brackets for vertical earth bar in wall-mount or floor-standing enclosure, H=45mm Fixing brackets for vertical earth bar in wall-mount or floor-standing enclosure, H=80mm 14, 117, 119, , 119, , 119, Kit for neutral bar earth blocks with 12x4mm² spring terminals 14, earth blocks with 3x16mm² spring terminals 14, Mounting plate for terminal block and earth bar in 116, 120 duct Mounting plate with 4 vertical DIN rails for terminal 117, 120 blocks Practic raisers 55, Modular device rail, L=1600mm 54, 66, Terminal block for auxiliaries 53, Trunking for door, L=2000mm 53, grommets for wiring through front 53, Flexible trunking for wiring to door 53, horizontal cable straps 14, 47, covers for horizontal cable straps 14, 47, horizontal trunking supports 14, 47, horizontal trunking sections, L=450mm, + 14, 47, 127 supports covers for vertical cable straps, L=1000mm 47, vertical cable straps, 47, vertical trunking supports 47, Vertical trunking, L=2000mm 47, Vertical partition Horizontal partition for wall-mount or floor-standing 94 enclosure Horizontal partition for duct Réf dans fichier 100F22200.rtf pas trouvé 123 dans indexe Insulated flexible bar 20x2mm, L=1800mm Insulated flexible bar 20x3mm, L=1800mm Insulated flexible bar 24x5mm, L=1800mm Insulated flexible bar 32x5mm, L=1800mm Insulated flexible bar 32x6mm, L=1800mm Insulated flexible bar 32x8mm, L=1800mm Surface-mount Pack enclosure, W=550mm, 2 11 rows Surface-mount Pack enclosure, W=550mm, 3 11 rows Surface-mount Pack enclosure, W=550mm, 4 11 rows Surface-mount Pack enclosure, W=550mm, 5 11 rows Surface-mount Pack enclosure, W=550mm, 6 11 rows Plain door for Pack enclosure, W=550mm, 2 rows Plain door for Pack enclosure, W=550mm, 3 rows Plain door for Pack enclosure, W=550mm, 4 rows Plain door for Pack enclosure, W=550mm, 5 rows Plain door for Pack enclosure, W=550mm, 6 rows Transparent door for Pack enclosure, W=550mm, 11 2 rows Transparent door for Pack enclosure, W=550mm, 11 3 rows Transparent door for Pack enclosure, W=550mm, 11 4 rows Transparent door for Pack enclosure, W=550mm, 11 5 rows Wall-mount enclosure, W=600mm, 6 modules Wall-mount enclosure, W=600mm, 9 modules Wall-mount enclosure, W=600mm, 12 modules Wall-mount enclosure, W=600mm, 15 modules Wall-mount enclosure, W=600mm, 18 modules Wall-mount enclosure, W=600mm, 21 modules Wall-mount enclosure, W=600mm, 24 modules Wall-mount enclosure, W=600mm, 27 modules Plain door for wall-mount enclosure, 6 modules Plain door for wall-mount enclosure, 9 modules Plain door for wall-mount enclosure, 12 modules Plain door for wall-mount enclosure, 15 modules Plain door for wall-mount enclosure, 18 modules Plain door for wall-mount enclosure, 21 modules Plain door for wall-mount enclosure, 24 modules Transparent door for wall-mount enclosure, 6 74 modules Transparent door for wall-mount enclosure, 9 74 modules Transparent door for wall-mount enclosure, modules Transparent door for wall-mount enclosure, modules Transparent door for wall-mount enclosure, modules Transparent door for wall-mount enclosure, modules Transparent door for wall-mount enclosure, modules Duct for wall-mount enclosure, W=300mm, 6 74 modules Duct for wall-mount enclosure, W=300mm, 9 74 modules Duct for wall-mount enclosure, W=300mm, modules Duct for wall-mount enclosure, W=300mm, modules Duct for wall-mount enclosure, W=300mm, modules Duct for wall-mount enclosure, W=300mm, modules Duct for wall-mount enclosure, W=300mm, modules Duct for wall-mount enclosure, W=300mm, modules Door for wall-mount enclosure duct, 6 modules Door for wall-mount enclosure duct, 9 modules Door for wall-mount enclosure duct, 12 modules Door for wall-mount enclosure duct, 15 modules Door for wall-mount enclosure duct, 18 modules Door for wall-mount enclosure duct, 21 modules Door for wall-mount enclosure duct, 24 modules Transparent door for wall-mount enclosure duct, modules Transparent door for wall-mount enclosure duct, modules Floor-standing enclosure, W=600mm, 27 modules Floor-standing enclosure, W=600mm, 30 modules Floor-standing enclosure, W=600mm, 33 modules Floor-standing enclosure extension, W=600mm, modules Floor-standing enclosure extension, W=600mm, modules Floor-standing enclosure extension, W=600mm, modules Plain door for wall-mount and floor-standing 74, 76 enclosure, 27 modules Plain door for floor-standing enclosure, modules 4

6 Index Cat. no Pages Cat. no Pages Plain door for floor-standing enclosure, modules Transparent door for wall-mount and 74, 76 floor-standing enclosure, 27 modules Transparent door for floor-standing enclosure, modules Transparent door for floor-standing enclosure, modules Duct for floor-standing enclosure, W=300mm, modules Duct for floor-standing enclosure, W=300mm, modules Duct for floor-standing enclosure, W=300mm, modules Door for wall-mount and floor-standing enclosure 74, 76 duct, 27 modules Door for floor-standing enclosure duct, 30 modules Door for floor-standing enclosure duct, 33 modules Transparent door for wall-mount and 74, 76 floor-standing enclosure duct, 27 modules Transparent door for floor-standing enclosure 76 duct, 30 modules Transparent door for floor-standing enclosure 76 duct, 33 modules IP55 enclosure, 7 modules IP55 enclosure, 11 modules 86, IP55 enclosure, 15 modules 86, IP55 enclosure, 19 modules IP55 enclosure, 23 modules IP55 enclosure, 27 modules IP55 enclosure, 33 modules IP55 enclosure extension, 7 modules IP55 enclosure extension, 11 modules 86, IP55 enclosure extension, 15 modules IP55 enclosure extension, 19 modules IP55 enclosure extension, 23 modules IP55 enclosure extension, 27 modules IP55 enclosure extension, 33 modules IP55 plain door, 7 modules IP55 plain door, 11 modules IP55 plain door, 15 modules IP55 plain door, 19 modules IP55 plain door, 23 modules IP55 plain door, 27 modules IP55 plain door, 33 modules IP55 transparent door, 7 modules IP55 transparent door, 11 modules IP55 transparent door, 15 modules IP55 transparent door, 19 modules IP55 transparent door, 23 modules IP55 transparent door, 27 modules IP55 transparent door, 33 modules IP55 duct, W=300mm, 7 modules IP55 duct, W=300mm, 11 modules IP55 duct, W=300mm, 15 modules 86, IP55 duct, W=300mm, 19 modules IP55 duct, W=300mm, 23 modules IP55 duct, W=300mm, 27 modules IP55 duct, W=300mm, 33 modules IP55 side panels, 7 modules IP55 side panels, 11 modules 86, IP55 side panels, 15 modules IP55 side panels, 19 modules IP55 side panels, 23 modules IP55 side panels, 27 modules IP55 side panels, 33 modules IP55 side panels with cut-outs, 7 modules IP55 side panels with cut-outs, 11 modules IP55 side panels with cut-outs, 15 modules IP55 side panels with cut-outs, 19 modules IP55 side panels with cut-outs, 23 modules IP55 side panels with cut-outs, 27 modules IP55 side panels with cut-outs, 33 modules Top and bottom plates, W=600mm 86, Top and bottom plates, W=300mm 86, IP55 4-module partial plain door for module 88 enclosures IP55 6-module partial plain door for 33-module 88 enclosures IP55 4-module partial door with cut-outs for module enclosures IP55 6-module partial door with cut-outs for module enclosures IP55 4-module partial TEGO door for module enclosures IP55 6-module partial TEGO door for 33-module 88 enclosures IP55 horizontal/vertical combination kit IP55 L combination kit IP55 square combination kit Canopy for IP55 enclosures, W=600mm Canopy for IP55 duct, W=300mm IP55 mounting upright 87, IP55 plinth gusset IP55 plinth cover panels, W=600mm IP55 plinth cover panels, W=300mm Pole-mount kit for enclosures IP55 lifting rings lifting rings external wall-mount brackets 15, mm plinth raiser for floor-standing enclosures mm plinth raiser for ducts lifting/reinforcement cross-members for single 80 wall-mount or floor-standing enclosures lifting/reinforcement cross-members for 2 75, 77, 80 wall-mount or floor-standing enclosures lifting/reinforcement cross-members for single 75, 77, 80 wall-mount or floor-standing enclosure and duct lifting/reinforcement cross-members for two 75, 77, 80 wall-mount or floor-standing enclosures and a duct Combination kit combination uprights Multiple combination kit Flush-mount kit for wall-mount enclosures, modules Flush-mount kit for wall-mount enclosures, modules Trunking spreader for Pack enclosure Pack flush-mount kit Trunking spreader for wall-mount or floor-standing 80 enclosure IP31 canopy for wall-mount or floor-standing 78 enclosure IP31 canopy for 2 wall-mount or 2 floor-standing 78 enclosures IP31 canopy for single wall-mount or floor-standing 78 enclosure and duct IP31 canopy for 2 wall-mount or 2 floor-standing 78 enclosures and duct IP43 door gasket kit, 6-21 modules IP43 door gasket kit, modules module partial door for wall-mount or 78 floor-standing enclosure module partial door with cut-out for human/ 78 switchboard interface (HSI) for wall-mount or floor-standing enclosure Plain mounting plate, 210x150mm Mounting plate with eight 22mm diameter holes Mounting plate with two 70x85mm holes for 89 industrial sockets 5

7 Index Cat. no Pages Cat. no Pages IP55 mounting plate with 70x85mm and 89 90x100mm holes for industrial sockets Mounting plate with 90x180mm hole for industrial 89 sockets Cable tie support adapter cable tie supports for wall-mount or 15, 34, 124 floor-standing enclosure cable tie supports for ducts Plain metal gland plate for wall-mount or 79 floor-standing enclosure Interface for FL21 gland plate for wall-mount or 79 floor-standing enclosure Plain metal gland plate for duct Interface for FL21 gland plate for duct Plastic gland plate and interface for Pack 11 enclosures Plain metal gland plate for Pack enclosures Plastic gland plate and interface for wall-mount or 79 floor-standing enclosure Plain FL21 gland plate Plastic gland plate and interface for ducts Gland plate for floor-standing enclosure plinth Gland plate for duct plinth Not yet available Not yet available FL21 gland plate with 20x16mm diameter entries FL21 gland plate with 16/30/47mm diameter 79 entries FL21 gland plate with 2x66mm diameter entries FL21 gland plate with 39x7-26mm diameter entries FL21 IP55 gland plate with 2x33-72mm diameter 91 entries Switchboard identification plate adhesive label holders, H=24mm, W=432mm 15, adhesive label holders, H=36mm, W=432mm 15, adhesive label holders, H=24mm, W=180mm adhesive label holders, H=36mm, W=180mm adhesive label holders, H=24mm, W=650mm 15, adhesive label holders, H=36mm, W=650mm 15, Earthing braid, 6mm² 15, Earthing wire, 6mm² 15, clip-on labels, 18x35mm 15, engraving plates, 18x35mm 15, clip-on labels, 18x72mm 15, engraving plates, 18x72mm 15, clip-on labels, 25x85mm 15, engraving plates, 25x85mm 15, Standard handle without insert EURO handle without insert ASSA handle without insert IP55 EURO handle for cylinder IP55 handle, L=155mm IP55 door latch with lock and 2 no. 405 keys Handle padlocking kit IP55 handle padlocking kit Barrel lock no Barrel lock no Barrel lock no. 1242E Barrel lock no. 3113A Barrel lock no. 2433A DIN double bar insert Screwdriver slot insert mm male triangle insert mm male triangle insert mm male triangle insert mm male triangle insert mm male square insert mm male square insert mm male square insert mm female square insert Touch-up paint brush 15, Touch-up spray paint 15, Adhesive drawing holder 15, Switchboard lighting Fan Grill with filter standard filters fine filters Resistor, 55W Resistor, 90W Resistor, 250W Thermostat IP55 screwdriver slot insert IP55 3mm double bar insert for handle IP55 barrel + 2 no. 2433A keys IP55 7mm male triangle insert for handle IP55 8mm male triangle insert for handle 92 (CNOMO) IP55 9mm male triangle insert for handle (EDF) IP55 barrel + 2 no. 1242E keys IP55 barrel + 2 no. 3133A keys IP55 barrel + 2 no. 455 keys IP55 6mm female square insert for handle IP55 7mm male square insert for handle IP55 8mm male square insert for handle IP55 6mm male square insert for handle IP55 screwdriver slot insert for door IP55 3mm double bar insert for door IP55 7mm male triangle insert for door IP55 8mm male triangle insert for door (CNOMO) IP55 9mm male triangle insert for door (EDF) IP55 6mm male square insert for door IP55 7mm male square insert for door IP55 8mm male square insert for door IP55 6mm female square insert for door self-adhesive label sheets for common symbols 15, self-adhesive label sheets for special symbols 15, 129 6

8 7

9 General presentation Prisma Plus electrical switchboards up to 630 A Presentation Prisma Plus - a tried and tested modular system A dependable electrical installation The total compatibility of Schneider devices with the Prisma Plus system is a key advantage in ensuring a high level of installation dependability. System design has been validated by type tests as per standard IEC and benefits from the combined experience of Schneider customers over many years. An upgradeable electrical installation Thanks to modular design, Prisma Plus switchboards can be modified easily to integrate new functions as needed. Maintenance operations, carried out with the switchboard de-energised, are fast and straight-forward due to easy access to devices. Total safety for personnel Work in a Prisma Plus switchboard is risk-free when carried out by qualified persons in compliance with all applicable safety regulations. Devices are installed behind protective front plates and only the operating handles are accessible. Additional internal separations protect against direct contact with live parts. Terminal shields are mandatory for installation of Compact NS and Interpact INS/INV devices in Prisma Plus enclosures. 8

10 General presentation Prisma Plus electrical switchboards up to 630 A PD PD Presentation IP55 enclosures. IP30/31/43 wall-mount and floorstanding enclosures. Pack wall-mount enclosures b Applications: v indoor enclosures containing all modular devices, for distribution switchboards in small and medium-sized commercial buildings (hotels, offices, shops), or for medium-sized and large residential installations (houses) v supplied mounted, with modular rails and front plates (48 modules (9 mm) per row) b rated operational current: 160 A b degree of protection: IP30 with or without door b degree of protection against mechanical impacts: v IK07 (without door) v IK08 (with door) b enclosure dimensions: v five heights: 480 mm to 1080 mm v width: 555 mm b depth: 157 mm without door v 186 mm with door and handle. IP30/31/43 wall-mount and floor-standing enclosures b Applications: v indoor wall-mount and floor-standing enclosures for all types of low-voltage switchboards (main, subdistribution and final) in commercial and industrial environments v supplied in kit form, can be combined side-by-side and one on top of another b rated operational current: 630 A b degree of protection: v IP30: with or without door v IP31: with door + canopy v IP43: with door + canopy + gasket b degree of protection against mechanical impacts: v IK07 (without door) v IK08 (with door) b enclosure dimensions: v eleven heights: 330 mm to 1830 mm (including the plinth for floor-standing enclosures) v two widths: 595 mm and 305 mm (duct) v depth: 205 mm without door v 250 mm with door + handle IP55 enclosures b Applications: v indoor enclosures for distribution, protection and process control in commercial and industrial applications v supplied in kit form, can be combined side-by-side and one on top of another b rated operational current: 630 A b degree of protection: IP55 b degree of protection against mechanical impacts: IK10 b enclosure dimensions: v seven heights: 450 mm to 1750 mm v width: basic enclosure: 600 mm v extensions: 575 and 325 mm (duct) v depth: 260 mm + 30 mm (handle). 9

11 Enclosures Pack wall-mount enclosures up to 630 A Presentation Pack electrical-distribution enclosures are specially designed for modular devices up to 160 A. The design, based on the wall-mount and floor-standing enclosures, offers a number of advantages: b easy device access and mounting b distribution using 125 and 160 A Powerclip insulated busbars as well as Distribloc and Polybloc distribution blocks b supply of devices using 63/80 A Multiclip distribution blocks or comb busbars b horizontal cable straps and trunking b earth and neutral bars b identification labels b closing accessories including barrel locks and inserts. The optimised depth and extra-thin door ensure perfect integration in all environments. In addition, Pack enclosures are specially equipped for easy on-site installation. Supplied with modular rails and front plates already mounted, they can also be fitted with blanking plates and plastic gland plates. They can be equipped with plain or transparent doors. Characteristics b rated operational current: 160 A b degree of protection: IP30 (with or without door) b degree of protection against mechanical impacts: IK07 (without door), IK08 (with door) b insulation: class 1 b compliance with standards: IEC b dimensions: v H: see the table on the next page v W: 555 mm v D: 157 mm without door 186 mm without door b Capacity per row: 48 width modules (9 mm each). PD PD PD

12 Enclosures Pack wall-mount enclosures DD Enclosures DD DD DD No. of rows Height of enclosure Enclosure Plain door Transparent door Reversible doors (opening to left or right), equipped with a handle (without barrel lock). For barrel locks and inserts, see page 82. DD Gland plates Top or bottom plate with additional plastic gland plate Plain metal gland plate DD DD Trunking spreader Trunking spreader DD Flush-mount kit Flush-mount kit

13 Enclosures Pack wall-mount enclosures Distribution Cable running DD A Powerclip busbars see page 99. Available in two lengths (450 and 750 mm) in three and four-pole versions. The busbars can be cut to length every 150 mm. They are supplied with clip-on covers that block off the connected cable lugs and can be cut as needed. selection 125 A Powerclip busbars Three-pole L = 450 mm L = 750 mm Four-pole L = 450 mm L = 750 mm A Powerclip busbars Three-pole L = 1000 mm Four-pole L = 1000 mm Busbar connection Four 125 A connections, L = 230 mm (for NG125, NSA and INS equipped with tunnel terminals) A 35 mm² ferrule for connection to tunnel terminals is crimped to one end. A 45 ring lug is crimped to the other end. 95 mm² tunnel terminals for INS : cat. no (set of 3) cat. no (set of 4) DD Four 160 A connections, L = 250 mm (for NSA160) A 45 mm² ferrule for connection to tunnel terminals is crimped to one end. A 45 ring lug is crimped to the other end DD DD Powerclip tap-off blocks Each block can be used to connect: b one 6 mm² and one 10 mm² cable (04151) b one 16 mm² cables (04152). Equipped with spring terminals. 12 Powerclip tap-off blocks with 6 mm² + 10 mm² terminals Powerclip tap-off blocks with 16 mm² terminals Connection cover Clip-on covers that block off the connected cable lugs and can be cut as needed. They maintain the IPxxB value for cables from 10 to 25 mm² with 90 angle lugs. 8 IPxxB covers for Powerclip busbars class mounting hardware Used for electrical connections to the copper bars. Set of 20 CHC M6 x 12 mm screws for Powerclip busbars DD A Polybloc distribution block see page A Polybloc distribution block, 1P Insulation voltage Ui: 750 V AC Nominal current: 160 (40 C) Upstream connection: tunnel terminals up to 70 mm 2 Downstream connections: spring loaded terminals up to 6 x 16 v flexible or rigid. rtio DD /160 A Distribloc distribution block see page A Distribloc distribution block A Distribloc distribution block

14 DD Enclosures Installation on a modular rail Pack wall-mount enclosures Device on a modular rail Device on a slotted plate NSA125/160, NG125 circuit breaker Depth behind front plate (mm) Useful length (mm) Rear modular rail DD Installation on a slotted mounting plate Recessed slotted mounting plate No. of vertical modules Useful height (mm) Useful width (mm) Depth behind front plate DD DD DD NG125 circuit breaker NSA125/160 circuit breaker Front plate No. of vertical modules Modular rail Modular ront plate NG125 Vigi NG125 6 b Direct supply via cables. Capacity of modular rail: 48 Multi 9 modules. Width of devices: NG125 3P: 9 modules NG1250 4P: 12 modules 63 A instantaneous or séelective 3P: 18 modules 63 A instantaneous or séelective 4P: 21 modules 63 A adjustable I/S/R 3P: 20 modules 63 A adjustable I/S/R 4P: 23 modules No. of vertical modules Modular rail Modular front plate Plain front plate Plain front plate NSA125/160 circuit breaker Vigi circuit breaker NSA125/ Capacity of modular rail: 48 Multi 9 modules. Note: To mix an NSA125/160 circuit breaker with Multi 9 modular devices, order (with the device) the symmetrical rail + raiser set (28041). Width of devices: NSA125/160 3P: 10 modules NSA125/160 4P: 14 modules Vigi NSA125/160 3P: 24 modules Vigi NSA125/160 4P: 27 modules Heigh in mm Plain front plate Transparent front plate 1 module (H = 50 mm) modules (H = 50 mm) modules (H = 200 mm) Other solutions see page 54 13

15 Enclosures Pack wall-mount enclosures Distribution Cable running DD Multiclip distribution block see page A Multiclip, 4P A Multiclip, 4P, 1/2 row Comb busbars see page 47. DD DD Cable running see page 126. Cable straps 12 horizontal cable straps covers for horizontal cable straps, L = 430 mm Trunking 4 horizontal sections, 60 x 30 mm, L = 450 mm + supports horizontal trunking supports fixing brackets, H = 15 mm (for vertical trunking) DD Earth bar see page Presentation The earth bar can be: b a bare earth bar, 12 x 3 mm with 330 mm of connection space, equipped with a 35 mm² tunnel terminal and on which earth blocks with spring terminals can be clipped b an earth bar (200 or 450 mm long), equipped with clamps with captive screws. Earth bar with spring terminals Bare earth bar, 12 x 3 mm with 330 mm of connection space, equipped with a 35 mm² tunnel terminal (for earth blocks with spring terminals) 4 earth blocks with 12 x 4 mm² spring terminals (L = 75 mm) earth blocks with 3 x 16 mm² spring terminals (L = 37 mm) fixing brackets, H = 15 mm (for vertical earth bar) DD Earth bar with clamps Earth bar with 40 clamps + one 35 mm² terminal (L = 450 mm) DD Neutral bar see page 121. A neutral bar is created by inserting insulating spacers behind an earth bar. Kit for neutral bar

16 Enclosures Pack wall-mount enclosures Accessories DD Blanking plates see page 128. Blanking strip, H = 46 mm, L = 1 m divisible blanking plates, H = 46 mm, L = 90 mm DD Identification labels see page 128. Clip-on labels 12 clip-on labels 18 x x x engraving plates 18 x Clip-on labels. 18 x x Adhesive labels 12 adhesive label holders, W = 432 mm H = 24 mm H = 36 mm divisible label holders, W = 650 mm H = 24 mm H = 36 mm Symbol sheets Adhesive labels. Set of ten adhesive symbol sheets standard special DD DD Enclosure accessories see page 129. Earthing braid, 6 mm² Earthing wire, 6 mm² DD DD Touch-up spray paint, RAL Touch-up paint brush, RAL DD Adhesive drawing holder DD Cable-tie supports 2 cable-tie supports DD Wall mounting 4 external wall-mount brackets

17 16

18 contents General presentation 18 Electrical switchboards up to 630 A 18 Examples of switchboard configurations 20 selection 26 Typical configuration with catalogue numbers 26 Determining catalogue numbers 30 Functional units 32 Compact NS400/ Compact NS100/ Interpact INS-INV250/ Manual source changeover system 40 Fupact INF 42 Modular devices NG125 circuit breakers NSA125/160 circuit breakers INS40/160 switch-disconnectors 44 Industrial control devices 48 Human-switchboard interface 50 Other devices 54 Switchboard lighting 56 Reserve space mm wide functional units 58 Compact NS100/ Interpact INS-INV250/ Modular devices NSA125/160 circuit breakers INS40/160 switch-disconnectors 62 Industrial control devices 64 Other devices 66 Fixing accessories 67 Reserve space 68 Enclosures 70 IP30/IP31/IP43 wall-mount enclosures Presentation 70 IP30/IP31/IP43 floor-standing enclosures Presentation 72 IP30/IP31/IP43 wall-mount enclosures 74 IP30/IP31/IP43 floor-standing enclosures 76 IP30/IP31/IP43 enclosures 78 Enclosure accessories 82 IP55 enclosures Presentation 84 IP55 enclosures Enclosure 86 Partitioning 94 Distribution 96 Main distribution A Powerclip busbars A rear busbars A multi-stage busbars 102 Insulated flexible bars 104 Overview of distribution blocks 106 Distribloc distribution block 108 Polybloc distribution block /630 A multi-stage distribution block 112 Multiclip distribution block 114 Terminal blocks support 116 Earth bars 118 Neutral bars 121 Terminal blocks 122 IP30/31/43/55 enclosures 124 Cable running 126 Front plate accessories 128 Air-conditioning accessories

19 General presentation Electrical switchboards up to 630 A Presentation PD39528 The Prisma Plus functional system The Prisma Plus functional system can be used for all types of low-voltage distribution switchboards up to 630 A, in commercial and industrial environments. Switchboard design is very simple. A functional structure for devices made up of wall-mount and floor-standing enclosures that can be used alone or combined. A distribution system made up of centralised distribution blocks and vertical busbars installed on the side or in the rear of the switchboard. Complete functional units Each device is part of a functional unit comprising: b a dedicated mounting plate for device installation b a front plate to block direct access to live parts b prefabricated busbar connections b systems for on-site connections and running of auxiliary wires. The functional units are modular and are arranged rationally, one on top of another, within the enclosure. The system includes everything required for functional unit mounting, supply and onsite connection. The components of the Prisma Plus system and those of the functional units in particular have been designed and tested taking into account device characteristics. This design approach ensures a high degree of reliability in system operation and optimum safety for personnel. PD Functional units are arranged rationally, one on top of another. 18

20 General presentation Electrical switchboards up to 630 A Presentation PD Prisma Plus enclosures Advantages of Prisma Plus switchboards Electrical characteristics b steel sheet metal b electrophoresis treatment + hot-polymerised polyester epoxy powder, white colour RAL b IP30 / 31 / 43 wall-mount enclosures v degree of protection: - IP30: with or without door - IP31: with door + canopy - IP43: with door + canopy + IP43 gasket v IK07 (without door), IK08 (with door) v can be dismantled v can be combined side by side and one on top of another v eight heights from 330 to 1380 mm v width: 595 mm v width of duct: 305 mm, can be combined side by side v depth: 250 mm with door (205 mm without door) b IP30 / 31 / 43 floor-standing enclosures v degree of protection: - IP30: with or without door - IP31: with door + canopy - IP43: with door + canopy + IP43 gasket v IK07 (without door), IK08 (with door) v can be dismantled v can be combined side by side v three heights: 1530, 1680 and 1830 mm v width: 595 mm v width of duct: 305 mm, can be combined side by side v depth: 250 mm with door (205 mm without door) b IP55 enclosures v IK10 v can be dismantled v can be combined side by side and one on top of another v width: 600 mm v seven heights: 450 to 1750 mm v widths: 325 and 575 mm, can be combined side by side and one on top of another v depth: 260 mm with door + 30 mm (handle). A dependable electrical installation The total compatibility of Schneider devices with the Prisma Plus system is a key advantage in ensuring a high level of installation dependability. System design has been validated by type tests and benefits from the combined experience of Schneider customers over many years. An upgradeable electrical installation Thanks to modular design, Prisma Plus switchboards can be modified easily to integrate new functional units as needed. Maintenance operations, carried out with the switchboard de-energised, are fast and straight-forward due to easy access to devices and the use of standard components. Total safety for personnel Devices are installed behind protective front plates; only the operating handles are accessible. The electrical installation and operating personnel are fully protected. In addition, all distribution components are protected by an IPxxB degree of protection. Terminal shields are mandatory for installation of Compact NS and INS/INV devices in Prisma Plus enclosures. Electrical switchboards built using the Prisma Plus functional system and Schneider recommendations fully comply with international standard IEC Prisma Plus components comply with standard IEC and have the following electrical characteristics: b rated insulation level of main busbars at rear of enclosure: 1000 V b rated operational current Ie (40 C): 630 A b rated peak withstand current Ipk: 53 kâ b rated short-time withstand current Icw: 25 ka rms / 1 second b frequency: 50/60 Hz. 19

21 General presentation Examples of switchboard configurations Presentation Incomer Compact NS250 4P Fixed, front connection Toggle Incoming cables via bottom to incoming connection block PD Distribution Polybloc distribution block Outgoing devices Multi 9 devices Supply Cable running Connection Motor circuit breakers Supply Cable running Connection 80 A Multiclip Comb busbars Straps + cover Terminal block at top of switchboard Comb busbars Straps + cover Terminal block at top of switchboard IP30 enclosure Wall-mount enclosure, W = 595 mm, H = 930 mm Plain door Partial plain door PD

22 General presentation Examples of switchboard configurations Presentation Incomer Interpact INS160 4P Incoming cables via top PD Distribution 160 A Powerclip busbars Outgoing devices Multi 9 devices Supply 80 A Multiclip Comb busbars Straps + cover Cable running Connection Terminal block in duct, W = 300 mm Motor circuit breaker + contactor combinations Supply Cable running Connection Cable wiring Straps + cover Terminal block in duct, W = 300 mm IP30 enclosure Wall-mount enclosure, W = 595 mm, H = 1230 mm Transparent door Duct, W = 305 mm, H = 1230 mm Plain door PD

23 General presentation Examples of switchboard configurations Presentation Incomer Compact NS250 Fixed, front connection Toggle Incoming cables via top to incoming connection block PD Distribution Powerclip busbars Outgoing devices Multi 9 devices Supply Cable running Connection Motor circuit breakers Supply Cable running Connection 80/200 A Multiclip Comb busbars Straps + cover Trunking Terminal block in duct, W=300mm Cable wiring Trunking Terminal block in duct, W=300mm IP30 enclosure Wall-mount enclosure, Transparent door W = 595 mm, H = 1230 mm Duct, W = 305 mm, Plain door H = 1230 mm PD

24 General presentation Examples of switchboard configurations Presentation Incomer Interpact INS160 Lateral handle Incoming cables via bottom, directly to device PD Distribution Distribloc distribution block Outgoing devices Multi 9 devices Supply Comb busbars Cable running Straps + cover Connection Terminal block at bottom of enclosure Motor control and protection devices Supply Comb busbars Cable running Trunking Connection Terminal block at bottom of enclosure IP55 enclosure Wall-mount enclosure, W = Transparent door 595 mm, H = 1250 mm PD

25 General presentation Examples of switchboard configurations Presentation Incomer Compact NS400 Fixed, front connection Toggle Incoming cables via bottom in duct (W = 300 mm) to incoming connection block PD Distribution Powerclip busbars Outgoing devices Compact NS250 Fixed, front connection Toggle Supply Multi 9 devices Supply Powerclip busbars with power supply block Comb busbars 200 A Multiclip Cable running Trunking Connection Vertical terminal block at bottom of floor-standing enclosure Motor control and protection devices Supply 200 A Multiclip Cable running Trunking Connection Vertical terminal block at bottom of floor-standing enclosure IP30 enclosure Floor-standing enclosure, Transparent door W = 595 mm, H = 1830 mm Duct, W = 305 mm, Plain door H = 1830 mm 24

26 General presentation Examples of switchboard configurations Presentation PD

27 selection Typical configuration with catalogue numbers Presentation PD NS250 functional units See page 34 Main distribution using Powerclip busbars See page 99 Modular device functional units See page 44 Distribution using 80 A Multiclip distribution blocks See page 114 Horizontal cable running using straps See page Modular device functional units See page 44 Distribution using comb busbars See page 44 Horizontal cable running using straps See page Modular device functional units See page 44 Distribution using 200 A Multiclip distribution See page 115 blocks Horizontal cable running using trunking See page Motor control and protection functional See page 48 units Horizontal cable running using trunking See page 127 Vertical cable running using trunking See page 127 Terminal block See page 116, 122 Earth bar See page

28 selection Typical configuration with catalogue numbers Presentation PD Device compartment See page 70 Connection compartment See page 70 Front plate See page 70 Transparent door See page 74 Plain door See page 74 27

29 selection Typical configuration with catalogue numbers PD Mounting plate for horizontal See page covers for horizontal cable See page 126 Compact NS100/250 with toggle straps 2 Front plate for horizontal See page horizontal trunking sections, See page 127 Compact NS100/250 with toggle 60 x 30 mm 3 Incoming connection block See page vertical trunking supports See page A power supply block See page Vertical trunking section, See page x 80 mm 5 Powerclip busbars See page Support for terminal block See page A, 4P, L=1000 mm and earth bar 6 Modular rail See page Modular rail, L=1600 mm See page Modular rail (adjustable) See page Terminal block See page Modular front plate, 3 modules See page Earth bar with 40 clamps See page Plain front plate, 4 modules See page Wall-mount enclosure, See page modules A Multiclip distribution block, See page Duct, 24 modules See page 74 4P A Multiclip distribution block, See page Transparent door for wall-mount See page 74 4P enclosure, 24 modules horizontal cable straps See page Plain door for duct, 24 modules See page 74 28

30 29

31 selection Determining catalogue numbers Presentation Starting with the electrical diagram: IP30 switchboard DD DD Install the incomer see page 34 b order the mounting plates and the front plates b the incoming connection block b the power supply block for the Powerclip busbars. DD Installation/connection 1 Device No. of vertical modules Fixed Compact NS DD Mounting plate Cut-out Upstream front plate front plate Connection block cables via top cables via bottom 2 DD Distribution using Powerclip busbars DD Device Power supply block Terminal shields (set of 2) Powerclip busbars Fixed Compact NS and Vigicompact NS DD Install the modular devices Multi 9 Order the mounting plates and front plates taking into account: b supply to the rows b cable running. Device No. of vertical 1 see page 44 modules All Multi 9 devices All supply systems (comb busbars, Multiclip) with cable straps and trunking sections Multi 9 devices Supply via 63/80 A Multiclip or comb busbars with cable straps Supply via 63/80 A Multiclip or comb busbars with cable straps DD DD Modular rail Modular front plate DD DD Device All Multi 9 devices All supply systems (comb busbars, Multiclip) with cable straps and trunking sections Multi 9 devices Supply via 63/80 A Multiclip or comb busbars with cable straps No. of vertical modules Modular rail Modular front plate 2 DD TeSys "U" see page 48 DD Device No. of vertical modules TeSys U model TeSys U model Useful length of rail (mm) Rear modular rail Transparent front plate b Multiclip distribution block see page 114 b cable running see page 126 Determine the size of the switchboard b count the number of occupied modules 19 modules b determine the corresponding wallmount enclosure 21 modules b order the additional plain front plate. Plain front plate see page 68 DD mm wide plain front plate 30

32 selection Determining catalogue numbers Presentation DD Plan the distribution system DD Powerclip busbars see page 99 DD Powerclip busbars Three-pole Four-pole DD Select the terminal blocks and the earth bar see page 116 DD DD Mounting plate for terminal block and earth bar Modular rail, L = 1600 mm Bare earth bar, 12 x 3 mm with 330 mm of connection space, equipped with a 35 mm² tunnel terminal (for earth blocks with spring terminals) 4 earth blocks with 12 x 4 mm² spring terminals (L = 75 mm) 4 earth blocks with 3 x 16 mm² spring terminals (L = 37 mm) DD Select the enclosures see page 78 1 DD IP wall-mount enclosure DD No. of vertical Height of modules enclosure Wall-mount enclosure (IP30) Enclosure Plain door Transparent door 2 DD Duct, W = 300 mm DD No. of vertical modules Duct (IP30) Height of duct Duct, W = 300 mm Plain door Transparent door Cable tie supports 3 4 cable-tie supports for 300 mm wide ducts 4 Accessories for lifting, handling, wall mounting, finishing parts, etc. DD

33 Functional units Installation Compact NS400/630 Horizontal Fixed Toggle Connection to the in-duct incoming connection block DD Cables via top to in-duct incoming connection block. Device No. of Mounting Cut-out front vertical plate plate modules Compact NS installed at top of switchboard NS400/630 (cables via top) NS400/630 (cables via bottom) Compact NS installed at bottom of switchboard NS400/630 (cables via bottom) NS400/630 (cables via top) Upstream front plate Incoming connection block DD Cables via bottom to in-duct incoming connection block. DD Distribution Powerclip insulated busbars Device Power supply block Powerclip insulated busbars Compact NS NS see page 99 NS see page 99 Powerclip insulated busbars, supplied by 400 A power supply block (04070). Other distribution solutions DD DD Rear busbars see page 100. Multi-stage busbars see page

34 DD Functional units Installation Compact NS400/630 Vertical Fixed Toggle or direct rotary handle Toggle Device No. of vertical modules (1) Mounting plate Cut-out front plate Upstream front plate Downstream frontplate Long terminal shields (set of 2) Compact NS and Vigicompact NS NS (3P) (4P) NS (3P) (4P) Vigi NS (3P) (4P) Vigi NS (3P) (4P) (1) With or without spreaders. DD Direct rotary handle Device No. of vertical modules (1) Mounting plate Cut-out front plate Upstream front plate Downstream front plate Long terminal shields (set of 2) Compact NS and Vigicompact NS NS (3P) (4P) NS (3P) (4P) Vigi NS (3P) (4P) (collar) Vigi NS (3P) (collar) (4P) (1) With or without spreaders. DD Distribution Powerclip insulated busbars Device Power supply block (without connection) Short terminal shields (set of 2) Powerclip insulated busbars Compact NS and Vigicompact NS NS400/630 and Vigi 3P see page 99 4P Powerclip insulated busbars, supplied by power supply block (04074) (supplied without connection). Other distribution solutions DD DD Rear busbars see page 100. Multi-stage busbars see page

35 DD DD Functional units Installation Compact circuit breaker with incoming connection block (04066). Compact NS100/250 Horizontal Fixed or plug-in Toggle Without cable duct: with incoming connection block Device No. of vertical modules Mounting plate Cut-out front plate Upstream front plate Connection block cables via top cables via bottom Fixed Compact NS NS100/ or Without cable duct: connection directly by cable Device No. of vertical modules Mounting plate Cut-out front plate Upstream front plate Long terminal shields Fixed Vigicompact NS Vigi NS100/ (3P) (4P) Maximum size of connection cables: 95 mm². With cable duct: direct connection to the device Cable tying Device No. of vertical modules Mounting plate Cut-out front plate Long terminal shields (set of 2) Fixed Compact NS and Vigicompact NS NS100/ (3P) (4P) NS100/ (3P) with ammeter module (4P) Vigi NS100/ (3P) (4P) Compact NS, plug-in NS100/ (3P) (4P) Direct connection to the Compact circuit breaker. DD Distribution Polybloc Device Polybloc 250 A Compact NS, Vigicompact NS, Fixed Compact NS and Vigicompact NS NS100/250 3P P Vigi NS100/250 3P P Compact NS, plug-in NS100/250 3P P DD Distribution using Polybloc (04034). Distribution via Powerclip insulated busbars and NS250 power supply block (04060). Powerclip insulated busbars Device Power supply block Terminal shields Powerclip busbars (set of 2) Fixed Compact NS and Vigicompact NS NS100/ see page 99 NS100/250 with (3P) see page 99 ammeter module (4P) Vigi NS100/ (3P) see page (4P) Compact NS, plug-in (1) NS100/ connection (3P) see page 99 must be made (4P) (1) Two additional modules are required; add a lower plain front plate (03802). Other distribution solutions DD DD Rear busbars, see page 100. Busbars in a duct, see page

36 DD Functional units Installation Compact NS100/250 Vertical Fixed Toggle Device No. of devices per row No. of vert. mod. (1) Mounting plate Cut-out front plate Upstream front plate Downstream front plate Long terminal shields (set of 2) Fixed Compact NS and Vigicompact NS NS100/ x 3P, 3 x 4P (3P) (4P) NS x 3P, 3 x 4P (3P) (4P) Vigi NS100/ x 3P, 3 x 4P (3P) (4P) Vigi NS x 3P, 3 x 4P (3P) (4P) (1) With or without spreaders, whatever the distribution solution (Powerclip insulated busbars, Polybloc distribution block, etc.). DD DD Accessories Blanking plate for vertical NS100/250 (03249): see page 128. DD Distribution Polybloc Device Polybloc 250 A Modular rail (adjustable) Fixed Compact NS and Vigicompact NS NS100/250 3P P Vigi NS100/250 3P P Distribution using a Polybloc distribution block (04034) on an adjustable modular device rail (03002). DD Powerclip insulated busbars Device Univ. power supply block (w/o connection) + connection Short terminal shields (set of 2) Powerclip busbars Fixed Compact NS and Vigicompact NS (1 device centred on mounting plate) NS100/ (3P) (4P) see page 99 Vigi NS100/ must be made (3P) (4P) see page 99 Distribution via Powerclip insulated busbars and a 250 A universal power supply block (04061) (without connection) + connection (04062). DD Other distribution solutions DD Rear busbars, see page 100. Busbars in a duct, see page

37 DD Functional units Installation Compact NS100/250 Horizontal, fixed Direct rotary handle or motor mechanism Without cable duct Device No. of Mounting Cut-out Upstream vertical modules (1) plate front plate front plate Fixed Compact NS and Vigicompact NS NS100/250 Dir. rotary handle NS100/250 Motor mech. Vigi NS100/250 Dir. rotary handle Downstream front plate Long terminal shields (3P) (4P) (3P) (4P) (collar) (1) Distribution using Polybloc. Size reduced two modules, lower front plate (03802) not needed (3P) (4P) DD With cable duct Device No. of Mounting Cut-out Downstream Long terminal shields vertical modules (1) plate front plate front plate Fixed Compact NS and Vigicompact NS NS100/250 Dir. rotary handle NS100/250 Motor mech. Vigi NS100/250 Dir. rotary handle (3P) (4P) (3P) (4P) (3P) (4P) (collar) (1) Distribution using Polybloc. Size reduced two modules, lower front plate (03802) not needed. DD Distribution Polybloc Device Polybloc 250 A Fixed Compact NS and Vigicompact NS NS100/250 3P P Vigi NS100/250 3P P Distribution using Polybloc (04034). DD Powerclip insulated busbars Device Univ. power supply block (w/o connection) Short terminal shields (set of 2) Fixed Compact NS and Vigicompact NS NS100/ (3P) (4P) Vigi NS100/ (3P) (4P) Powerclip busbars see page 99 see page 99 Distribution via Powerclip insulated busbars and a 250 A universal power supply block (04061) (supplied without connection). DD Other distribution solutions DD DD Rear busbars, see page 100. Busbars in a duct, see page

38 DD Functional units Installation Compact NS100/250 Vertical Fixed Direct rotary handle Device No. of devices per row No. of vert. mod. (1) Mounting plate Cut-out front plate Fixed Compact NS and Vigicompact NS NS100/ x 3P, 3 x 4P NS x 3P, 3 x 4P Vigi NS100/ 160 Vigi NS x 3P, 3 x 4P 1 4 x 3P, 3 x 4P Upstream front plate Downstream front plate Long terminal shields (3P) (4P) (3P) (4P) (3P) (4P) (collar) (collar) (3P) (4P) (1) With or without spreaders,whatever the distribution solution (Powerclip insulated busbars, Polybloc distribution block, etc.). Accessories DD DD Blanking plate for vertical NS100/250 (03249): see page 128. DD Distribution Polybloc Device Polybloc 250 A Modular rail (adjustable) Fixed Compact NS and Vigicompact NS NS100/250 3P P Vigi NS100/250 3P P Distribution using a Polybloc distribution block (04034) on an adjustable modular device rail (03002). DD Powerclip insulated busbars Device Univ. power supply block (w/o connection) connection Short terminal shields (set of 2) Powerclip busbars Fixed Compact NS and Vigicompact NS (1 device centred on mounting plate) NS100/ (3P) (4P) see page 99 Vigi NS100/ must be made (3P) (4P) see page 99 Distribution via Powerclip insulated busbars and a 250 A universal power supply block (04061) (supplied without connection) + connection (04062). DD Other distribution solutions DD Rear busbars, see page 100. Busbars in a duct, see page

39 Functional units Interpact INS-INV250/630 Horizontal Direct front handle DD Installation Without cable duct: with connection block Device No. of vertical modules Mounting plate Cut-out front plate Upstream front plate Connection block cables via top cables via bottom Interpact INS-INV INS-INV or Interpact INS-INV250 with incoming connection block (04066). DD With cable duct: direct connection to the device Device No. of vertical modules Mounting plate Cut-out front plate Upstream front plate Long terminal shields (set of 2) Interpact INS-INV INS-INV INS-INV320/ cables via top INS-INV320/630 cables via bottom Direct connection to Interpact INS-INV250. DD Distribution Polybloc Device Polybloc 250 A Interpact INS-INV INS-INV250 3P P Distribution using Polybloc (4P). DD Powerclip insulated busbars Device Power supply block Powerclip busbars Interpact INS-INV INS-INV see page 99 INS-INV320/ see page 99 INS-INV500/ see page 99 Other distribution solutions DD DD Distribution via Powerclip insulated busbars and NS250 power supply block (04060). Rear busbars, see page 100. Multi-stage busbars, see page

40 DD Functional units Installation Interpact INS-INV250/630 Vertical Direct front handle Lateral handle Device No. of Mounting Cut-out vertical modules (1) plate front plate Upstream Downstream front plate front plate Long terminal shield (set of 2) Interpact INS-INV INS-INV250 front handle INS-INV250 lateral handle INS-INV320/400 front handle INS-INV500/630 front handle (1) With or without spreaders. DD Distribution Polybloc Device Polybloc Modular rail 250 A adjustable Interpact INS-INV INS-INV250 front handle INS-INV250 lateral handle 04037: copper spacer. 3P P P P Distribution using a Polybloc distribution block (04034) on an adjustable modular device rail (03002). DD Powerclip insulated busbars Device Power supply block (w/o connection) + connection Short terminal shield (set of 2) Powerclip busbars Interpact INS-INV INS-INV see page 99 INS-INV320/ must be made see page 99 Distribution via Powerclip insulated busbars and a 250 A universal power supply block (04061) (without connection) + connection (04062). Other distribution solutions DD DD Rear busbars, see page 100. Multi-stage busbars, see page April

41 reset O OFF ON I Functional units Manual source changeover system Fixed NS100/250, front connection Direct rotary handle DD Source changeover system with mechanical interlocking Device No. of vertical modules Mounting plate Cut-out front plate Upstream front plate Downstream front plate Compact NS with direct rotary handle NS100/ Interlock Coupling accessory (for 3P device) (for 4P device) Long terminal shields (set of 2) (3P) (4P) 40

42 O I DD Functional units Source changeover system with mechanical interlocking Manual source changeover system INS-INV250 Front direct rotary handle Device No. of vertical modules Mounting plate Cut-out front plate Upstream front plate Downstream front plate Source changeover system with mechanical interlocking INS-INV250 changeover system x OFF ON I ON Mechanical interlock Coupling accessory (for 3P device) (for 4P device) Long terminal shields (set of 2) DD Complete source changeover assembly Device No. of vertical modules Mounting plate Complete source changeover assembly INS-INV250 changeover system Cut-out front plate Upstream front plate Downstream front plate Rating For 3P device For 4P device Complete source 100 A changeover assembly 160 A A A Coupling accessory Long terminal shields (set of 2) (for 3P device) (for 4P device)

43 Functional units Fupact INF Horizontal Direct front rotary handle DD Installation Device No. of devices per row No. of vertical modules Switch-disconnector fuses Mounting plate Cut-out front plate Downstream front plate Long terminal shields (qty per device) INF32/40 3/4P INF63 3P P x 2 INF100/160 (1) 3P x 6 4P x 8 (1) For direct distribution, downstream front plate (03802) not needed. INF32/40. DD INF100/160. DD Distribution Multi-stage busbars in a duct Device Connection Multi-stage busbars Switch-disconnector fuses INF32/40 must be made see page 102 INF63 must be made INF100/160 must be made 42

44 Functional units Fupact INF Vertical Direct front rotary handle DD Installation INF32/40. Device No. of devices per row No. of vertical modules Switch-disconnector fuses Mounting plate Cut-out front plate Downstream front plate Long terminal shields (qty per device) INF32/40 4 x 3P x 4P INF63 3 x 3P x 4P x 2 INF100/160 (1) 2 x 3P x 6 2 x 4P x 8 (1) For direct distribution, downstream front plate (03802) not needed. DD INF100/160. DD Distribution Polybloc distribution block Device Polybloc Adjustable modular device rail Switch-disconnector fuses INF100/160 3P P Other distribution solutions DD Multi-stage busbars in a duct, see page

45 PD Functional units Presentation Modular devices NG125 circuit breakers NSA125/160 circuit breakers INS40/160 switch-disconnectors General A rigid modular rail Made using an aluminium alloy, the rail design is extremely rigid. The rail supports are crimp mounted. Fast mounting The pre-mounted rail supports have positioning studs to guide the rail at the rear of the enclosure. Only two mounting screws are required. Multiple functions A number of devices clip directly onto the rear of the rails, including 80 A and 200 A Multiclip distribution blocks, all horizontal cable-running accessories such as cable straps and trunking supports, as well as the supports for earth bars. Supply from all directions Supply to the rows, using comb busbars or Multiclip distribution blocks, can be via: b a Polybloc distribution block installed on the incoming device b Powerclip insulated busbars installed behind the devices b multi-stage busbars installed in a lateral duct b flat busbars installed at the rear of the enclosure. PD Distribution using Powerclip busbars: see page 99. Distribution using Distribloc in a Pack wall-mount enclosure: see page 108. Distribution blocks Multiclip distribution blocks Fast and secure front connection using spring terminals. Particularly reliable connections, will not loosen over time, insensitive to vibrations and thermal variations. All types of modular devices can be mixed. Easy balancing of phases. Interchangeable devices. Easy installation upgrades. Fully insulated. Comb busbars Direct connection to device terminals or via a connector. Fully insulated. Can be cut to length. Cable running Cable straps Easy and fast to install. Low cost. Trunking Perfectly integrated cable running. Attractive. 44

46 DD Functional units Multi 9 devices Modular devices NG125 circuit breakers NSA125/160 circuit breakers INS40/160 switch-disconnectors Device No. of vertical modules Modular rail Modular front plate All Multi 9 devices All supply systems (comb busbars, Multiclip) with cable straps and trunking sections Multi 9 devices y 40 A Supply via 63/80 A Multiclip or comb busbars with cable straps Capacity of modular rail: 48 Multi 9 modules. Note: For a modular row with a 160 A (half row) and 200 A Multiclip distribution block positioned directly below a non-modular mounting plate (Compact, Interpact, etc.), or at the top of a switchboard, add one vertical module (i.e ) and a plain upstream front plate (03801). DD Supply: 80 A Multiclip. Cable running: cable straps. Mounting requires 3 vertical modules. NG125 circuit breaker Device No. of vertical modules Modular rail Modular front plate NG125 circuit breaker NG125, Vigi NG Direct supply via cables. Capacity of modular rail: 48 Multi 9 modules. Width of NG125 circuit breakers: NG125 3P : 9 Multi 9 modules NG125 4P : 12 Multi 9 modules Vigi NG125 3P : 18 Multi 9 modules Vigi NG125 4P : 21 Multi 9 modules DD NSA125/160 circuit breaker Device No. of vertical modules Modular rail (adjustable) Modular front plate NSA125/160 circuit breaker NSA125/ Vigi NSA125/160 Direct supply via cables. Capacity of modular rail: 48 Multi 9 modules. Note: To mix an NSA125/160 circuit breaker with Multi 9 modular devices, order (with the device) the symmetrical rail + raiser set(28041). Width of devices: NSA125/160 3P: 10 Multi 9 modules NSA125/160 4P: 14 Multi 9 modules Vigi NSA125/160 3P: 24 Multi 9 modules Vigi NSA125/160 4P: 27 Multi 9 modules DD INS switch-disconnector Device No. of vertical modules Modular rail Modular front plate INS40/160 INS40/ INS100/ with long terminal shields Direct supply via cables. Capacity of modular rail: 48 Multi 9 modules. Width of devices: INS40/80: width 10 Multi 9 modules INS100/160: width 15 Multi 9 modules 45

47 Functional units Powerclip insulated busbars Modular devices NG125 circuit breakers NSA125/160 circuit breakers INS40/160 switch-disconnectors Busbar selection see page 99. DD DD DD Tap-off blocks for insulated busbars (04151). Supply to a 200 A Multiclip distribution block (04021). DD Connection Cover for connection Rear busbars Busbar selection see page 100. DD DD DD A Multiclip connection (04029). 125 A connection to a comb busbar (04145). Busbars in a duct Busbar selection see page 102. DD DD Supply to a 200 A Multiclip distribution block (04024). 46

48 DD Functional units Distribloc distribution block Modular devices NG125 circuit breakers NSA125/160 circuit breakers INS40/160 switch-disconnectors 125 A Distribloc distribution block A Distribloc distribution block see page 108 DD Multiclip distribution blocks Multiclip, 80 A, 4P Multiclip, 63 A, 4P, 1/2 row Multiclip, 200 A, 2P Multiclip, 200 A, 3P Multiclip, 200 A, 4P Multiclip, 160 A, 4P, 1/2 row Connection between 200 A Multiclip and Powerclip insulated busbars see page 114 DD Comb busbars For C60 circuit breakers 1P 24-module comb busbar (9 mm modules) Two 48-module comb busbars (9 mm modules) P 24-module comb busbar (9 mm modules) Two 48-module comb busbars (9 mm modules) P 24-module comb busbar (9 mm modules) Two 48-module comb busbars (9 mm modules) P 24-module comb busbar (9 mm modules) Two 48-module comb busbars (9 mm modules) For C120 and NG125 circuit breakers 1P (W = 430 mm, 16 poles) P (W = 430 mm, 16 poles) P (W = 430 mm, 16 poles) P (W = 430 mm, 16 poles) Thoot caps (set of 20) DD DD Cable running Blanking plates Cable straps 12 vertical cable straps covers, 1-meter long, for vertical cable straps horizontal cable straps covers, 430 mm long, for horizontal cable straps Trunking 4 horizontal sections, 60 x 30 mm, L = 450 mm Vertical section, 80 x 60 mm, L = 2 m horizontal trunking supports vertical trunking supports see page 126 Blanking strip, H = 46 mm, L = 1 m divisible blanking plates, H = 46 mm, L = 90 mm see page

49 Functional units Industrial control devices DD Series D and K contactors Device No. of vertical modules Useful rail length (mm) Series D and K contactors Series D and K contactors y 40 A Rear modular rail Plain front plate DD GV2/GV3 circuit breakers Device No. of vertical modules Useful length of rail (mm) Modular rail Cut-out front plate GV2/GV3 circuit breakers GV GV Width of devices without lateral auxiliaries: 45 mm. Accessories DD Modular blanking plates: see page 128. DD GV2 + contactor combination Device No. of vertical modules Useful length of rail (mm) GV2 + contactor combination GV2 + Series D or K contactor y 40 A Rear modular rail Transparent front plate Plain front plate Width of devices without lateral auxiliaries: 45 mm. DD TeSys U model Device No. of vertical modules Useful length of rail (mm) Rear modular rail Transparent front plate TeSys U model TeSys U model Width of devices without lateral auxiliaries: 45 mm. 48

50 Functional units Industrial control devices DD LH4 soft starters Device LH4 soft starters LH4 N1 LH4 N2 Width of devices: LH4 N1: 45 mm. LH4 N2: 90 mm. No. of vertical modules Useful length of rail (mm) Rear modular rail Plain front plate DD Tego Power Device Tego Power Tego Power 2 to 8 feeders No. of vertical modules Mounting plate Transparent front plate Upstream front plate Downstream front plate DD ATS01 soft starters Device No. of vertical modules Useful length of rail (mm) Modular rail Plain front plate Modular rail ATS01N103/106FT ATS01N109/112FT ATS01N206 to ATS01N222 to ATS01N230LY ATS01N244LY ATS01N244Q DD No. of vertical modules Recessed slotted mounting plate Plain front plate Slotted mounting plate ATS012N272LY ATS012N285LY ATS012N272Q ATS012N285Q Width of devices: ATS01N103/106FT: 22,5 mm ATS01N109/112FT: 45 mm ATS01N206 to 212: 45 mm ATS01N222 to 232: 45 mm ATS01N230LY: 180 mm ATS01N244LY: 180 mm ATS01N244Q: 180 mm ATS012N272LY: 180 mm ATS012N285LY: 180 mm ATS012N272Q: 180 mm ATS012N285Q: 180 mm DD LV/LV transformer Device No. of vertical modules Recessed slotted mounting plate Plain front plate LV/LV transformer ABL6-TS/TD up to VA ABL6-RF up to 120 W

51 Functional units Human-switchboard interface DD DD Measurement devices with interface and plastic mounting plates Front plate with cut-outs, four mounting plates and one plain mounting plate for 72 x 72 mm devices. A A A A Presentation The interface for 72 x 72 and 96 x 96 mm measurement devices is made up of: b a special front plate with cut-outs (03904) for plastic mounting plates b plastic mounting plates for the 72 x 72 or 96 x 96 mm devices. The front plate can be equipped with: b five mounting plates with cut-outs for 72 x 72 mm devices b four mounting plates with cut-outs for 96 x 96 mm devices. It can also be equipped with plain plastic mounting plates to blank off any unused positions. The plain mounting plates can be easily cut out for lamps, pushbuttons or 72 x 72 mm devices. Each mounting plate has a cable-running system for auxiliary wires and can be identified by a label. Installation The interface for 72 x 72 and 96 x 96 mm devices is installed similar to a front plate: b in the device zone of enclosures b on a partial door with cut-outs in wall-mount and floor-standing enclosures (except IP55). The degree of protection for installed devices is IP30. selection Front plate (3 modules) for five 72 x 72 mm or four 96 x 96 mm devices Mounting plate for 72 x 72 mm with cut-outs device plain Mounting plate for 96 x 96 mm device with cut-outs plain Doors with cut-outs for the measurement-device interface Mounting on a cubicle door cut-out (System P). Partial door 6 modules IP30/31/43 enclosures (08851) see page 78 DD DD DD A A A A The mounting plates have guides for auxiliary wires. Mounting plates can be identified by a label (not supplied). Note: For degree of protection IP55, devices must be installed behind a transparent door. If they are installed on the door, use the mounting plates intended for IP55 enclosures (see page 86). Mounting in the device zone of an enclosure (). DD A A A A Visor for measurement devices Presentation The interface with the plastic mounting plates for 72 x 72 mm and 96 x 96 mm devices can be mounted on a visor. The visor can be installed on 300 and 400 mm wide doors with cut-outs in cubicles or on partial doors in wall-mount and floor-standing enclosures. It is supplied with a drilling diagram for mounting on a plain door. selection Visor for measurement devices DD A Visor mounted on a cubicle door cut-out. A 60 A 60 A 60 Visor mounted on the partial door of an enclosure. 50

52 Functional units Human-switchboard interface DD Measurement devices on a metal front plate Installation The 72 x 72 mm or 96 x 96 mm measurement devices are installed directly on a front plate with cut-outs, H = 150 mm (3 modules): b in the device zone of enclosures b on a partial door with cut-outs in wall-mount and floor-standing enclosures (except IP55). The degree of protection for installed devices is IP30. Unused positions are blanked off using blanking plates. Device No. of vertical modules Cut-out front plate Measurement device Six 72 x 72 mm measurement devices Four 96 x 96 mm measurement devices One 144 x 144 mm device + four 72 x 72 devices DD Accessories 72 x 72 mm blanking plate x 96 mm blanking plate Blanking plates have knock-outs for 22 mm lamps or pushbuttons DD DD DD Pushbuttons or lamps Installation in the device zone on a metal front plate with cut-outs. Device No. of vertical modules Cut-out front plate Pushbuttons 12 pushbuttons or lamps (22 mm diameter)

53 MERLIN GERIN Vigirex RH10M Test Test no trip Functional units Human-switchboard interface DD Powerlogic system Device No. of vertical modules Cut-out front plate PowerMeter PM Power Meter PM700/500/800 (96 x 96 mm case) Installation in the device compartment. DD Vigilohm Device No. of vertical modules Modular rail Cut-out front plate Vigilohm TR22A/AH (1 TR + 6 measurement devices, 72 x 72 mm) EM9, TR5A, SM21 (modular devices) Installation in the device compartment DD Vigirex Reset on fault Device No. of vertical modules Modular rail Cut-out front plate Vigirex RH10/RH21/RH99 relays Modular device x 72 mm cases see page 50 RHU relay (72 x 72 mm cases) see page 50 RMH relay and RM12T multiplexer RMH (modular devices) RM12T (72 x 72 mm cases see page 50 Installation in the device compartment. 52

54 2 3 A A 4 5 Functional units Human-switchboard interface DD Multi 9 measurement device Device No. of vertical modules Modular rail Cut-out front plate Multi 9 measurement device Lamps, pushbuttons, etc Ammeter, voltmeter, etc Installation in the device compartment. DD Cable running Cable trunking for doors, L = 2000 mm Flexible trunking for wiring to door Terminal block for auxiliaries grommets for wiring through front DD DD Auxiliary wiring on partial door with cut-outs. Trunking for a door. Flexible trunking to protect and guide wires. DD DD Terminal block for auxiliaries. Grommets. 53

55 Functional units Other devices On a modular rail On a slotted plate DD Installation on a modular rail Depth behind front plate (mm) Useful length (mm) Modular rail Modular rail (adjustable) 47 to Recessed modular rail Rear modular rail Modular rail, with 4 holes, dia. 6.4 mm, 450 mm between centres DD Modular rail (adjustable) (03002). DD Plain and transparent front plates: see page 56. Recessed modular device rail (03003). DD Rear modular rail (03004). DD Modular rail, L = 1600 mm (04226). DD Installation on a slotted plate No. of vertical modules Slotted mounting plate Flat slotted mounting plate Recessed slotted mounting plate Useful height (mm) Useful width (mm) Depth behind front plate Flat slotted mounting plate (03170). DD DD Plain and transparent front plates: see page 56. Recessed slotted mounting plate (03171). 54

56 Functional units Other devices Accessories DD Clip-nuts for slotted mounting plates These nuts are used to install various devices (contactors, transformers) on a slotted mounting plate. They can also be installed on the cable-tie supports in enclosures. 20 clip-nuts for slotted mounting plates M M M DD Clip-nuts for modular rails These nuts are used to install various devices on a modular rail. 20 clip-nuts for modular rails M M M DD Clip-nuts for lateral and longitudinal cross-members These nuts can be installed on the functional uprights in IP30/55 wall-mount and floor-standing enclosures. 20 M6 captive nuts DD Pratic raiser Colour RAL The raiser clips onto a slotted mounting plate or a modular rail. It is 27 mm wide and serves to raise a device 10 mm. It is made of an insulating material and can directly receive terminal blocks, modular devices, etc. 5 Pratic raisers DD M5 self-trapping screws 20 M5 self-trapping screws for mounting on functional uprights DD Hexagonal spacers M5 hexagonal spacers 4 spacers H = 9 mm H = 23 mm H = 55 mm M6 hexagonal spacers 4 spacers H = 9 mm H = 23 mm H = 25 mm H = 55 mm M8 hexagonal spacers 4 spacers H = mm DD

57 Functional units Switchboard lighting Reserve space DD Switchboard lighting This system is generally used to illuminate the front of a switchboard. The kit is made up of: b a base b a neon tube b afront plate with cut-out (1 module) b a door contact. Characteristics b supply voltage: 220/240 V b power rating: 8 W. selection No. of modules Switchboard lighting Installation in a wall-mount or floor-standing enclosure (). DD Device compartment, W = 600 mm 500 mm wide plain front plate 1 module (H = 50 mm) modules (H = 100 mm) modules (H = 150 mm) modules (H = 200 mm) modules (H = 250 mm) modules (H = 300 mm) modules (H = 450 mm) modules (H = 600 mm) DD mm wide transparent front plate 4 modules (H = 200 mm) modules (H = 300 mm) modules (H = 450 mm) modules (H = 600 mm)

58 57

59 DD mm wide functional units Installation Compact NS100/630 Vertical Fixed Toggle or direct rotary handle Toggle Device No. of vertical modules (1) Mounting plate Cut-out Upstream front plate front plate Downstream front plate Long terminal shields Compact NS NS100/ (3P) (4P) NS (3P) (4P) NS (3P) (4P) Vigi Compact NS Vigi NS100/ (3P) (4P) Vigi NS400/ (3P) (4P) (1) With or without spreaders. DD Direct rotary handle Device No. of vertical modules (1) Mounting plate Cut-out front plate Long terminal shields (set of 2) Compact NS NS100/ (3P) (4P) NS400/ (3P) (4P) (1) With or without spreaders. 58

60 DD mm wide functional units Distribution Compact NS100/630 Vertical Fixed Toggle or direct rotary handle Polybloc Device 250 A Polybloc Modular rail (adjustable) Compact NS and Vigi Compact NS NS100/250 3P and Vigi 4P Distribution via a Polybloc distribution block (04034) on a modular device rail (03011). Powerclip insulated busbars Device Univ. power supply block (w/o conn.) + connection Short terminal shields (set of 2) Compact NS and Vigi Compact NS NS100/ (3P) and Vigi (4P) NS400/630 and Vigi (3P) (4P) Powerclip busbars see page 99 Note: available space at top of enclosure after mounting the universal power supply block: NS100/630 = 7 modules Vigi NS100/630 = 9 modules. Space required for power supply block on Powerclip = 5 modules. DD Multi-stage busbars Device Connection Short terminal shields (set of 2) NS100/250 and Vigi NS400/630 and Vigi (3P) (4P) (3P) (4P) Multi-stage busbars see page 102. see page 102. Other distribution solutions DD Rear busbars, see page

61 300 mm wide functional units Interpact INS-INV250/630 Vertical Front, direct rotary handle DD Installation Device No. of vertical modules (1) Mounting plate Cut-out Downstream front plate front plate Long terminal shields Interpact INS-INV INS-INV INS-INV320/ INS-INV500/ (1) With or without spreaders. 60

62 300 mm wide functional units Interpact INS-INV250/630 Vertical Front, direct rotary handle DD Distribution Polybloc Device Polybloc 250 A Modular rail (adjustable) Interpact INS-INV INS-INV250 3P P Distribution via a Polybloc distribution block (04034) on an adjustable modular device rail (03011). DD Powerclip insulated busbars Device Univ. power supply block (w/o conn.) + connection Short terminal shields (set of 2) Powerclip busbars Interpact INS-INV INS-INV see page 99 INS-INV320/ Note : available space at top of enclosure after mounting the universal power supply block: INS-INV250/630 = 7 modules. Space required for power supply block on Powerclip = 5 modules. Distribution via Powerclip insulated busbars and a 250 A universal power supply block (04061) (without connection) + connection (04064). DD Multi-stage busbars Device Connection Short terminal shields (set of 2) Multi-stage busbars Interpact INS-INV switch-disconnector INS-INV see page 102. INS-INV320/ see page 102. Other distribution solutions DD Rear busbars, see page

63 300 mm wide functional units Modular devices NSA125/160 circuit breakers INS40/160 switch-disconnectors DD Multi 9 devices Device All Multi 9 devices All supply systems with cable straps or trunking Multi 9 devices y 40 A No. of modules Modular rail Supply via 63 A Multiclip or comb busbars with cable straps Capacity of modular rail: 20 Multi 9 modules. Modular front plate Supply via comb busbars. Width of NG125 circuit breakers: NG125 3P: 9 Multi 9 modules NG125 4P: 12 Multi 9 modules Vigi NG125 3P: 18 Multi 9 modules DD Supply via 63 A Multiclip. DD NSA125/160 circuit breaker Device No. of vertical modules Modular rail (adjustable) Modular front plate Downstream front plate NSA125/160 circuit breaker NSA125/ Capacity of modular rail: 20 Multi 9 modules. Note: To mix an NSA125/160 circuit breaker with Multi 9 modular devices, order (with the device) the symmetrical rail + raiser set (28041). Width of devices: NSA125/160 3P: 10 Multi 9 modules NSA125/160 4P: 14 Multi 9 modules DD INS switch-disconnector Device No. of modules Modular rail Modular front plate Downstream front plate INS160 INS40/ INS100/160 with long terminal shields Capacity of modular rail: 20 Multi 9 modules. Width of devices: INS40/80: width 10 Multi 9 modules INS100/160: width 15 Multi 9 modules 62

64 300 mm wide functional units Modular devices NSA125/160 circuit breakers INS40/160 switch-disconnectors Powerclip insulated busbars see page 99. DD Rear busbars see page 100. DD Multi-stage busbars see page 102. DD Distribloc distribution blocks see page 108. DD Multiclip distribution blocks see page 114. DD Comb busbars see page 47 DD Cable running see page 126. DD Blanking plates see page 128. DD

65 300 mm wide functional units Industrial control devices DD Series D and K contactors Device No. of vertical modules Useful rail length (mm) Series D and K contactors Series D and K contactors y 40 A Modular rail (adjustable) Plain front plate DD GV2/GV3 circuit breakers Device No. of vertical modules Useful rail length (mm) Modular rail Cut-out front plate Upstream front plate Downstream front plate GV2/GV3 circuit breakers GV GV Width of devices without lateral auxiliaries: 45 mm. Accessories DD Modular blanking plates, see page 128 DD GV2 + contactor combination Device No. of Useful rail Modular rail Transparent Plain front plate vertical length (mm) (adjustable) front plate modules GV2 + contactor combination GV2 + Series D or K contactor y 40 A Width of devices without lateral auxiliaries: 45 mm. DD TeSys U model Device No. of vertical modules Useful rail length (mm) Modular rail (adjustable) Transparent front plate TeSys U model TeSys U model Width of devices without lateral auxiliaries: 45 mm. 64

66 300 mm wide functional units Industrial control devices DD LH4 soft starters Device No. of vertical modules LH4 soft starters LH4 N1 LH4 N2 Width of devices: LH4 N1: 45 mm LH4 N1: 45 mm LH4 N2: 90 mm. Useful rail length (mm) Modular rail Plain front (adjustable) plate DD LV/LV transformer Device No. of vertical modules LV/LV transformer ABL6 up to 400 VA Slotted mounting plate Plain front plate Cable running and distribution Multiclip distribution blocks see page 114 DDD Comb busbars see the Telemecanique catalogue and see page 47 DD Cable running see page 126 DD

67 300 mm wide functional units Other devices On a modular rail On a slotted mounting plate DD Installation on a modular rail Modular rail Modular rail Adjustable modular rail Modular rail, L = 1600 mm with 4 holes, dia. 6.4 mm, 450 mm between centres DD DD Modular rail (03010). Adjustable modular rail (03011). DD DD Modular rail, L = 1600 mm (04226). Plain and transparent front plates, see page 68. DD Installation on a slotted mounting plate No. of modules Slotted mounting plate Flat slotted mounting plate Recessed slotted mounting plate Useful Useful width height (mm) (mm) Depth behind front plate mm mm mm mm DD DD Recessed slotted mounting plate. Flat slotted mounting plate. 66

68 Functional units Fixing accessories DD Clip-nuts for slotted mounting plates These nuts are used to install various devices (contactors, transformers) on a slotted mounting plate. They can also be installed on the cable-tie supports in enclosures. 20 clip-nuts for slotted mounting plates M M M DD Clip-nuts for modular rails These nuts are used to install various devices on a modular rail. 20 clip-nuts for modular rails M M M DD Clip-nuts for lateral and longitudinal cross-members These nuts can be installed on the functional uprights in IP30/55 wall-mount and floor-standing enclosures. 20 M6 captive nuts DD Pratic raiser Colour RAL The raiser clips onto a slotted mounting plate or a modular rail. It is 27 mm wide and serves to raise a device 10 mm. It is made of an insulating material and can directly receive terminal blocks, modular devices, etc. 5 Pratic raisers DD M5 self-trapping screws 20 M5 self-trapping screws for mounting on functional uprights DD Hexagonal spacers M5 hexagonal spacers 4 spacers H = 9 mm H = 23 mm H = 55 mm M6 hexagonal spacers 4 spacers H = 9 mm H = 23 mm H = 25 mm H = 55 mm M8 hexagonal spacers 4 spacers H = mm DD

69 Functional units Switchboard lighting Reserve space DD Switchboard lighting This system is generally used to illuminate the front of a switchboard. The kit is made up of: b a base b a neon tube b afront plate with cut-out (1 module) b a door contact. Characteristics b supply voltage: 220/240 V b power rating: 8 W. selection No. of modules Switchboard lighting Installation in a wall-mount or floor-standing enclosure (). DD Device compartment, W = 600 mm 500 mm wide plain front plate 1 module (H = 50 mm) modules (H = 100 mm) modules (H = 150 mm) modules (H = 200 mm) modules (H = 250 mm) modules (H = 300 mm) modules (H = 450 mm) modules (H = 600 mm) DD mm wide transparent front plate 4 modules (H = 200 mm) modules (H = 300 mm) modules (H = 450 mm) modules (H = 600 mm)

70 57

71 Enclosures IP30/IP31/IP43 wall-mount enclosures Presentation Carefully designed in every detail, Prisma Plus wall-mount enclosures are the solution for all common switchboard configurations up to 630 A: b a wide range with eight heights from 330 to 1380 mm, in 50 mm steps b two widths: v 595 mm for devices v 305 mm for cables, terminal blocks, busbars or devices b can be combined side-by-side and one on top of another b a standard degree of protection IP30 (with or without a door) that can be upgraded to IP43 b a structure designed to facilitate fast and total access at all times to the devices and all the connection points in the switchboard b a discreet appearance that blends well in commercial settings, including entry halls or passageways b colour RAL9001. Prisma Plus wall-mount enclosures comply with standard EN PD Combination of a wall-mount enclosure with a 300 mm wide duct. PD The entire front can be removed for fast, direct access to all the devices. 70

72 Enclosures IP30/IP31/IP43 wall-mount enclosures Presentation Carefully designed in every detail, Prisma Plus floor-standing enclosures are the solution for all common switchboard configurations up to 630 A: b three heights from 1530 to 1830 mm, including a 150 mm plinth b two widths: v 595 mm for devices v 305 mm for cables, terminal blocks, busbars or devices b side-by-side combinations b a standard degree of protection IP30 (with or without a door) that can be upgraded to IP43 b a structure designed to facilitate fast and total access at all times to the devices and all the connection points in the switchboard b a discreet appearance that blends well in commercial settings, including entry halls or passageways Prisma Plus floor-standing enclosures comply with standard EN PD Combination of a basic floor-standing enclosure with a 300 mm wide duct. 71

73 Enclosures IP30/IP31/IP43 floor-standing enclosures Presentation PD PD The sides slip naturally into place with the help of the positioning guides. The enclosures are easily mounted on the wall using a practical system based on a hinged fork. PD PD Only four screws are required to secure the cover panels. The front of the plinth can be removed to facilitate spreading of cables and fixing to the floor (floor-standing enclosures). 72

74 Enclosures IP30/IP31/IP43 floor-standing enclosures Presentation PD PD The comfortable handles drive the door locking bolts. They are equipped with keylocks (405 keys) and can be fitted with other locks or inserts. PD PD The structure is made up of a rigid rear panel with four screw-on, metal, corner struts (wallmount enclosures). Wall-mount enclosures and the 300 mm wide ducts can be easily combined using metal gussets (wall-mount enclosures). 73

75 Enclosures IP30/IP31/IP43 wall-mount enclosures DD Wall-mount enclosure (IP30) DD DD DD No. of vertical modules Height of enclosure Enclosure Plain door Transparent door Wall-mount enclosure (IP30) b reversible doors (opening to left or right), equipped with a handle and keylock (key 405). For other possibilities, see page 82. DD Duct, W = 300 mm (IP30) DD DD DD No. of vertical modules Duct (IP30) Height of duct Duct, W=300mm Plain door Transparent door b the duct is supplied with a combination kit for the enclosure b reversible doors (opening to left or right), equipped with a handle and keylock (key 405). For other possibilities, see page 82. DD Duct front plate, see page 68. DD Canopy (IP31) The addition of a canopy over the wall-mount enclosure (and the duct) equipped with a door ensures compliance with the degree of protection IP31 (see page 78). Gasket (IP43) When the wall-mount enclosure (and the duct) is equipped with a canopy, a gasket for the door of the wall-mount enclosure (and the duct) ensures compliance with the degree of protection IP43 (see page 78). 74

76 Enclosures IP30/IP31/IP43 wall-mount enclosures DD Side-by-side combination Enclosure mm wide duct The combination kit (two combination brackets) is supplied with the duct. To make the combination more rigid, particularly during transport, it is advised to use a set of cross-members secured to the rear of the switchboard. for ordering Set of two lifting/reinforcement cross-members for single wall-mount enclosure and 300 mm wide duct DD Enclosure + enclosure A combination kit (must be ordered) ensures the mechanical connection between the two wall-mount enclosures. To make the combination more rigid, particularly during transport, it is mandatory to use a set of cross-members secured to the rear of the switchboard. for ordering Combination kit Set of two lifting/reinforcement cross-members for two wall-mount enclosures DD Enclosure mm wide duct + enclosure A combination kit is supplied with the duct. Only one additional combination kit must be ordered for the mechanical connection between the two wall-mount enclosures and the duct. To make the combination more rigid, particularly during transport, it is mandatory to use a set of cross-members secured to the rear of the switchboard. for ordering Combination kit Set to two lifting/reinforcement cross-members for two wall-mount enclosures and a duct DD Vertical combination A combination kit (must be ordered) ensures the mechanical connection between the two wall-mount enclosures. To make the combination more rigid, particularly during transport, it is mandatory to use a set of combination uprights secured to the rear of the switchboard. For more than 33 modules, a mechanical connection kit is used to join the 2 combination uprights. for ordering Combination kit Two combination uprights Multiple combination kit

77 Enclosures IP30/IP31/IP43 floor-standing enclosures DD Floor-standing enclosure (IP30) DD DD DD DD DD Basic floor-standing enclosure. No. of vertical modules Height of enclosure Basic enclosure Enclosure extension Plain door Transparent door Floor-standing enclosure (IP30) b two basic floor-standing enclosures cannot be combined b to create a switchboard comprising a number of enclosures, use a basic floorstanding enclosure and one or more floor-standing enclosure extensions b floor-standing enclosure extensions are supplied with a combination kit for the basic floor-standing enclosure. b reversible doors (opening to left or right), equipped with a handle and keylock (key 405). For other possibilities, see page 82. Floor-standing enclosure extension. DD Duct, W = 300 mm (IP30) DD DD DD No. of vertical modules Height of duct Duct, W = 300 mm Plain door Transparent door Duct, W = 300 mm (IP30) b the duct is supplied with a combination kit for the basic enclosure b reversible doors (opening to left or right), equipped with a handle and keylock (key 405). For other possibilities, see page 82. DD Duct front plate, see page 68. DD Canopy (IP31) The addition of a canopy over the floor-standing enclosure (and the duct) equipped with a door ensures compliance with the degree of protection IP31 (see page 78). Gasket (IP43) When the floor-standing enclosure (and the duct) is equipped with a canopy, a gasket for the door of the floor-standing enclosure (and the duct) ensures compliance with the degree of protection IP43 (see page 78). 76

78 Enclosures IP30/IP31/IP43 floor-standing enclosures DD Floor-standing enclosure combinations Basic enclosure mm wide duct The combination kit (two mechanical combination brackets) is supplied with the duct. To make the combination more rigid, particularly during transport, it is advised to use a set of cross-members secured to the rear of the switchboard. for ordering Set of two lifting/reinforcement cross-members for basic floor-standing enclosure and 300 mm wide duct Basic floor-standing enclosure + duct. DD Basic enclosure + enclosure extension A combination kit for mechanical connection is supplied with the floor-standing enclosure extension. To make the combination more rigid, particularly during transport, it is mandatory to use a set of cross-members secured to the rear of the switchboard. for ordering Set of two lifting/reinforcement cross-members for basic floor-standing enclosure and extension Basic floor-standing enclosure + extension. DD Basic enclosure mm wide duct + extension A combination kit for mechanical connection is supplied with the duct and the floorstanding enclosure extension. To make the combination more rigid, particularly during transport, it is mandatory to use a set of cross-members secured to the rear of the switchboard. for ordering Set of two lifting/reinforcement cross-members for basic floor-standing enclosure, 300 mm wide duct and extension Basic floor-standing enclosure + duct + extension. DD Plinth raiser Plinth raiser, H = 100 mm for basic floor-standing enclosure or extension for a duct, W = 300 mm

79 Enclosures IP30/IP31/IP43 enclosures Partial doors Canopy DD Partial door b plain door or with cut-outs (for the interface with 72 x 72 or 96 x 96 mm measurement devices, see page 50) b height: 6 modules b installation: v on a wall-mount enclosure at least 12 modules high (H u 630 mm) v on a basic floor-standing enclosure or extension b reversible (opening to left or right), equipped with a handle and keylock (key 405). Note: Each wall-mount enclosure and basic floor-standing enclosure or extension can be equipped with only one partial door. The front must be completed with another door. The useful height behind a partial door is five modules. selection Partial plain door Partial door with cut-outs for 72 x 72 or 96 x 96 mm devices module wall-mount enclosure with a 6-module partial plain door and an 18-module plain door. DD Interface for 96 x 96 mm measurement devices on a partial door with cut-outs. DD Canopy (IP31) The addition of a canopy over a wall-mount or floor-standing enclosure equipped with a door ensures compliance with the degree of protection IP31. Canopy for wall-mount or floor-standing enclosure alone for wall-mount encl. + duct or floor-standing encl. + duct for 2 wall-mount or 2 floor-standing enclosures for 2 wall-mount encl. + duct or 2 floor-standing encl. + duct DD Gasket (IP43) When the switchboard is equipped with a canopy, a gasket for the doors ensures compliance with the degree of protection IP43. For combinations, order one gasket per door. Gasket for one wall-mount encl./one floor-standing encl./one duct 6 to 21 modules (L = 3300 mm) to 33 modules (L = 5300 mm) DD Flush-mount kit Flush-mount kit for wall-mount enclosures, 6 to 18 modules Flush-mount kit for wall-mount enclosures, 21 to 27 modules

80 Enclosures IP30/IP31/IP43 enclosures Gland plates DD Gland plates Metal gland plates Enclosures (wall-mount, floor-standing, 300 mm wide ducts) are supplied with a plastic gland plate installed on the top or bottom panel. To cover all connection needs, the plastic gland plate can be replaced by a plain metal gland plate supplied separately. Plain metal gland plate for wall-mount and basic floor-standing enclosure or extension for a duct, W = 300 mm DD Special gland plates Enclosures (wall-mount, floor-standing, 300 mm wide ducts) are supplied with a plastic gland plate installed on the top or bottom panel. This gland plate can be replaced by an interface plate with cut-outs for special cable entry systems (membranes, FL21, etc.). Interface plate with FL21 cut-outs for wall-mount and basic floor-standing enclosure or extension for a duct, W = 300 mm Special FL21 gland plate plain x Ø29/48 mm x Ø21/23 mm x Ø16 mm entries Ø16/30/47 mm entries x Ø66 mm entries DD Gland plate for floor-standing enclosure plinth Gland plate for plinth for basic floor-standing enclosure or extension for a duct, W = 300 mm DD Top or bottom plate with plastic gland plate b top or bottom plate with cut-outs and a plastic gland plate b can be installed: v at the top or bottom of a wall-mount enclosure (or duct) v at the top of a floor-standing enclosure (or duct). Plate with cut-outs + plastic gland plate for wall-mount or floor-standing enclosure for a duct, W = 300 mm

81 Enclosures IP30/IP31/IP43 enclosures Installation accessories DD Lifting accessories Lifting rings The lifting rings are used to move a single wall-mount or floor-standing enclosure. For combined enclosures, use the lifting/reinforcement cross-members (see below). selection Set of two lifting rings for single wall-mount or floor-standing enclosures DD Lifting/reinforcement cross-members The lifting cross-members, already installed to reinforce combined enclosures, have holes for lifting. selection Set of two lifting/reinforcement cross-members for wall-mount or floor-standing enclosure alone for two wall-mount or two floor-standing enclosures for a wall-mount or floor-standing enclosure mm wide duct for two wall-mount or floor-standing enclosures mm wide duct DD DD Trunking spreader For a professional-looking connection between the trunking and the enclosure. Can be installed at the top or bottom. The spreader is marked for cut-outs for standard trunking sizes. The maximum capacity is two 250 x 80 mm trunking sections. Trunking spreader

82 Enclosures IP30/IP31/IP43 enclosures Installation accessories DD Wall mounting Switchboards can be mounted on a wall in three manners: b through the rear of the switchboard b using the lifting/reinforcement cross-members b using external wall-mount brackets. selection Set of two lifting/reinforcement cross-members See previous page. Four external wall-mount brackets Mounting through the rear. DD Mounting using the lifting/reinforcement cross-members. DD Mounting using the external wall-mount brackets (08803). 81

83 Enclosures Enclosure accessories Door handles and locks DD Handles (except IP55) DD EURO handle without barrel DD ASSA handle without barrel DD Standard handle without insert or barrel Can be equipped with all the barrel locks and inserts presented below. Barrel locks, inserts DD DD DD Padlocking The barrel locks and inserts below can be mounted on handle and on all the door handles of the Prisma Plus range (except IP55) after removing the standard barrel lock (key no. 405). Barrel locks Barrel lock + 2 keys no Barrel lock + 2 keys no Barrel lock + 2 keys no. 1242E Barrel lock + 2 keys no. 3113A Barrel lock + 2 keys no. 2433A Inserts DIN double bar insert Screwdriver slot insert mm male triangle insert mm male triangle insert mm male triangle insert mm male triangle insert mm male square insert mm male square insert mm male square insert mm female square insert Handle padlocking kit The kit can be installed on the door handles of the Prisma Plus range (except IP55) equipped with any of the barrel locks and inserts above. 82

84 83

85 Enclosures IP55 enclosures Presentation Prisma Plus IP55 enclosures are designed for indoor switchboards in severe environments such as industrial and agricultural buildings, basements, kitchens, etc. All components can be used to form switchboards that: b have heavy-duty IP55 / IK10 characteristics b can be dismantled and combined to facilitate installation, on-site connections and later modifications b offer functional installation of control and indication devices (lights, pushbuttons, etc.) on the front of the switchboard, on a plain or partial door b offer functional installation of Schneider industrial sockets b can be installed anywhere in a building (on a wall, on a pole, on free-standing structures, etc.). PD PD Installation on a wall structure. 84

86 Enclosures IP55 enclosures Presentation PD PD Sockets on a partial door. Sockets on the side. PD PD Lights and pushbuttons on a partial door. Extended rotary handle on a door. PD PD Gland plates on an enclosure and a duct. Gland plates on an enclosure. 85

87 Enclosures IP55 enclosures DD Enclosure DD DD DD No. of vertical modules Height (mm) Enclosure Plain door Transparent door Basic enclosure b reversible doors (opening to left or right), equipped with a handle and keylock (key 405). For other possibilities, see page 92. DD Duct, W = 300 mm DD DD No. of vertical modules Height (mm) Rear + door, W = 300 mm Top and bottom plates Duct, W = 300 mm b reversible doors (opening to left or right), equipped with a handle and keylock (key 405). For other possibilities, see page 92. DD Enclosure extension DD DD DD DD No. of vertical Height Side-by-side combination Vertical combination modules (mm) Rear + Top and bottom Rear + Side panels plates Enclosure extension b the enclosure extension uses the same doors as the basic enclosure. 86

88 Enclosures IP55 enclosures DD Combination kits IP55 enclosures can be combined side-by-side and vertically. To make a combination, start with a basic enclosure and add a duct or one (or more) enclosure extensions using the corresponding combination kits. selection Combination kit horizontal/vertical (two double struts) "L" shape (one triple strut and one single strut) square shape (one quadruple strut) Note: For combinations of more than two enclosures, the switchboard must be reinforced using mounting uprights (08391), see page 90. DD Examples of combinations Vertical combination A basic enclosure is positioned above an enclosure extension, whatever its height. Use the horizontal/vertical combination kit with two double struts. for the configuration opposite Item 1 1 basic enclosure rear plate for enclosure extension set of two side panels horizontal/vertical combination kit See previous page for plain and transparent doors for basic enclosures and extensions. DD "L" combination The "L" shape is created by combining two enclosures (extension or duct) with a basic enclosure. for the configuration opposite Item 1 1 basic enclosure rear + door for duct, W = 300 mm set of two top and bottom plates for duct rear plate for enclosure extension set of two side panels "L" combination kit horizontal/vertical combination kit See previous page for plain and transparent doors for basic enclosures and extensions. DD Square combination The square shape is created by combining three enclosures (extension or duct) with a basic enclosure. for the configuration opposite Item 1 1 basic enclosure rear plates for enclosure extensions set of two top and bottom plates for enclosure extensions set of two side panels square combination kit horizontal/vertical combination kits 2 x mounting uprights (to reinforce the switchboard) 3 x See previous page for plain and transparent doors for basic enclosures and extensions. 87

89 Enclosures IP55 enclosures Partial doors Side panels with cut-outs Partial doors Whether plain or with cut-outs, they can be mounted on basic enclosures or extensions at least eleven modules high (H = 650 mm). They are equipped with: b hinges that open 170 b a 8 mm male triangle insert (key not supplied). The front can be completed with a standard door, either plain or transparent. Each basic enclosure or extension can be equipped with only one partial door. DD Partial plain door Partial plain door 4 modules (H = 200 mm) for enclosures from 11 to 27 modules high modules (H = 300 mm) for enclosures 33 modules high DD Partial door with cut-outs Designed for two mounting plates with 22 mm diameter devices or Schneider industrial sockets. Partial door with cut-outs 4 modules (H = 200 mm) for enclosures from 11 to 27 modules high modules (H = 300 mm) for enclosures 33 modules high They are supplied with an insulating plain mounting plate that can be used to blank off a reserve hole or to install all types of devices (sockets, EPO devices, measurement devices). The dimensions of the two holes are 200 mm x 112 mm. DD Tego Dial partial door Designed for "Tego Dial" mounting plates (H = 100 mm) on which it is possible to mount control, monitoring, measurement and indication devices. Tego Dial partial door 4 modules (H = 200 mm) for enclosures from 11 to 27 modules high modules (H = 300 mm) for enclosures 33 modules high The cut-out is 375 mm wide (five 75 mm modules). For selection of Tego Dial mounting plates, see the Schneider industrial control catalogue. DD Side panel with cut-out Side panel with two cut-outs (only one for 7 and 11-module panels) for mounting plates intended for 22 mm diameter devices and those for industrial sockets. These panels simply replace a standard side panel. Can be mounted on the left or right-hand side. Supplied with one blanking plate (except for the 7 and 11-module panels). 1 side panel with cut-out 7 mod mod mod mod mod mod mod

90 Enclosures IP55 enclosures Functional mounting plates Mounting plates for 22 mm diameter devices or industrial sockets Plastic mounting plates are used for 22 mm diameter devices or industrial sockets on the outside of the switchboard. They can be installed: b horizontally on the partial doors with cut-outs b vertically on the side panels with cut-outs horizontally vertically at any point on a door or side panel. DD Plain mounting plate A plain plate is used to blank off partial doors or side panels with cut-outs. Plain mounting plate, 210x150 mm Can be used to mount any type of device (EPO devices, measurement devices, sockets). DD Mounting plate for 22 mm diameter devices For installation of eight 22 mm diameter devices (lights, switches, pushbuttons, etc.). Mounting plate with eight 22 mm diameter holes Supplied with 4 blanking plug DD DD Mounting plate for Schneider industrial sockets Mounting plate with two 65 x 85 mm holes. Intended for the installation of: b 10/16 A residential sockets b inclined 16 A IP44 and IP67 sockets. Mounting plate with two 65 x 85 mm holes Supplied with a 65 x 85 mm blanking plate. DD Mounting plate with two holes, 65 x 85 mm and 90 x 100 mm Intended for the installation of: b inclined 16 and 32 A IP44 and IP67 sockets in the 90 x 100 mm hole (1) b residential sockets (< 10/16 A) in the 65 x 85 mm hole (1a) b inclined 16 A IP44 and IP67 sockets in the 65 x 85 mm hole (1b). Mounting plate with two holes, 65 x 85 mm and 90 x 100 mm Supplied with a 65 x 85 mm blanking plate. 89

91 Enclosures IP55 enclosures Installation accessories DD Mounting supports Mounting uprights The uprights are used to mount on a wall one or more enclosures combined horizontally or vertically. The uprights leave space behind the switchboard for cable running and to improve ventilation. Colour RAL7016. For one enclosure, order two uprights. For each enclosure extension or duct, order one additional upright. 1 mounting upright (L = 1950 mm) Supplied with: b two adjustable fixing brackets b one joint for combination with a plinth or another upright. Note: To create the configuration opposite, order: three mounting uprights (08391 x 3). DD Plinth, H = 150 mm The plinth, installed in the factory or on-site, raises the switchboard to protect it and facilitate spreading of cables arriving from a trough. Colour RAL7016. The wall-fixing brackets supplied with the plinth ensure that the switchboard cannot topple over. For the basic enclosure, order two gussets and one 600 mm wide plinth cover panel. For each enclosure extension or duct, order one additional gusset and the corresponding cover panel. Plinth gusset Plinth cover panel, W = 600 mm (for enclosure) Plinth cover panel, W = 300 mm (for duct) Note: To create the configuration opposite, order: three plinth gussets (08392 x 3) one plinth cover panel, W = 600 mm (08393) one plinth cover panel, W = 300 mm (08394). DD Wall structure The switchboard can be mounted on the structure in the factory or on site. Two wall-fixing brackets supplied with the basic enclosure ensure that the switchboard cannot topple over. Colour RAL mounting upright (L = 1950 mm) plinth gusset Plinth cover panel, W = 600 mm (for enclosure) Plinth cover panel, W = 300 mm (for duct) Nota : To create the configuration opposite, order: three mounting uprights (08391 x 3) three plinth gussets (08392 x 3) one plinth cover panel, W = 600 mm (08393) one plinth cover panel, W = 300 mm (08394). DD Free-standing structure The free-standing structure is simply two wall structures combined back-to-back. The switchboard can be positioned anywhere. It can be fixed to the floor and moved easily using the lifting rings (08396). It can be equipped with one or more enclosures with Schneider sockets. Colour RAL mounting upright (L = 1950 mm) plinth gusset Plinth cover panel, W = 600mm (for enclosure) Plinth cover panel, W = 300 mm (for duct) Note: To create the configuration opposite, order: four mounting uprights (08391 x 4) four plinth gussets (08392 x 4) two plinth cover panels, W = 600 mm (08393 x 2). 90

92 Enclosures IP55 enclosures Installation accessories DD Mounting on a pole The kit is used to mount an enclosure or an enclosure + duct combination, without drilling, to an I-beam or concrete pole that can be rectangular or cylindrical. The maximum circumference of the pole is 580 mm. Pole-mount kit for enclosures The kit is made up of: b two reinforcement cross-members to support the enclosure b mounting components and hardware. DD Canopies Installed on the mounting uprights or directly on the wall, canopies improve switchboard protection against vertically falling water and objects. Colour RAL7016. Canopy, W = 600 (for enclosure) Canopy, W = 300 (for duct) Supplied with: b the hardware required for mounting on the uprights b the components required for combination with another canopy. DD Membrane-type gland plates (IP55) These gland plates are made of an insulating material and simply replace the standard steel gland plates supplied with the enclosure (two plates) or the duct (one plate). Different size cables can enter the switchboard through the bottom without using cable glands while maintaining the degree of protection IP55. Gland plate with 39 entries for three 14 to 26 mm diameter cables + four 10 to 20 mm diameter cables + thirty-two 7 to 16 mm diameter cables Gland plate with 2 entries for two 33 to 72 mm diameter cables DD DD DD Lifting rings The lifting rings are secured directly to the switchboard or to the mounting uprights. Supplied with mounting hardware. Set of two lifting rings

93 Enclosures IP55 enclosures Closing accessories DD Presentation Handles The small plain and transparent doors (7 to 23 modules) are supplied with a small handle comprising a barrel lock no The large plain and transparent doors (27 to 33 modules) are supplied with a large handle comprising a barrel lock no The partial doors are supplied with an 8 mm male triangle insert. All doors can receive as optional equipment: b a large or small handle with a barrel lock no The latter can be replaced by other barrel locks or special inserts b a large EURO handle, supplied without a barrel lock b door inserts (squares, triangles, double bars, screwdriver slots). Replacement handles Door latch with lock and 2 no. 405 keys Handle L = 155 mm) with lock and 2 no. 405 keys EURO handle without a barrel lock (1) (1) Do not suit to barrels with an automatic return stroke of the key. DD Door insert These inserts simply replace a standard handles. Screwdriver slot insert mm double bar insert mm male triangle insert mm male triangle insert (CNOMO) mm male triangle insert (EDF) mm male square insert mm male square insert mm male square insert mm female square insert DD Handle barrel locks and inserts Barrel locks These components may equip handles after removing the standard barrel lock no Barrel lock + 2 keys no. 2433A Barrel lock + 2 keys no Barrel lock + 2 keys no E Barrel lock + 2 keys no A Other A and E combinations are available from Ronis, please consult us. Inserts Screwdriver slot insert mm female square insert mm male square insert mm male square insert mm male square insert mm male triangle insert mm male triangle insert (CNOMO) mm male triangle insert (EDF) mm double bar insert

94 Enclosures IP55 enclosures Closing accessories DD Padlocking Kit designed for three padlocks. IP55 handle padlocking kit The kit can be installed on all IP55 doors, except those equipped with an EURO lock. 93

95 Distribution Partitioning DD Horizontal partitioning Presentation The partition is a metal barrier installed in a wall-mount enclosure, a floor-standing enclosure or a 300 mm wide duct. It is used to: b separate the functional units from one another b create a physical separation between devices and a terminal block, for example. It is mounted directly on the functional uprights. Lateral and rear knock-outs are available for cable running or the installation of busbars at the rear of the switchboard. selection Horizontal partition for wall-mount or floor-standing enclosure for a duct, W = 300 mm DD

96 Distribution Partitioning DD Vertical partitioning Presentation The metal partition creates a physical separation between the device compartment and the 300 mm wide duct of a wall-mount enclosure or a floor-standing enclosure. It is used to: b separate the devices from busbars or a distribution block installed in the duct b set up a special zone for terminal blocks in the duct. There are knock-outs for cable running. It can be cut to length every 150 mm and can be used for partitioning up to 33-module in wall mount enclosure and floor-standing enclosure (H = 1830 mm). selection Vertical partition DD

97 Distribution Main distribution Powerclip busbars Powerclip busbars Powerclip busbars are compact and fully insulated (IPxxB). They are supplied ready for installation in the switchboard. There are three and four-pole versions with ratings from 125 to 630 A. Available in four lengths, they can by cut every 150 or 200 mm, depending on the rating (see page 99). PD PD PD Additional 35 mm² blocks installed on the connection between the device and the busbars. Powerclip tap-off blocks for 6 and 10 mm² cables. PD PD Clip-on covers insulate the cable lugs. 200 A connection for a Multiclip distribution block. 96

98 Distribution Polybloc centralised distribution block The Polybloc distribution block is designed for optimum installation directly downstream of horizontal Compact NS100/250 and Interpact INS250 devices. Mounting is very fast. It simply hooks onto the device mounting plate. Electrical connections are made directly to the device terminals. It has the same width as the devices and does not require extra space in the switchboard. The connection terminals are slanted to facilitate cable entry and reduce the space required behind the front plate (see page 110) 400 A rear busbars The rear busbars are mounted directly on the rear of enclosures. There are three and four-pole versions with ratings from 160 to 400 A. Available in two lengths, 1000 and 1400 mm, they can be cut as needed (see page 100). PD PD Main distribution Polybloc centralised distribution block 400 A rear busbars 630 A multi-stage busbars 630 A multi-stage busbars The multi-stage busbars are installed in a 300 mm wide duct. They are particularly useful for distribution to two enclosures on each side of the duct. All connection points are easily accessible from the front. The inclination of the bars facilitates connections and improves cable running. There are three and four-pole versions with ratings from 160 to 630 A. Available in two lengths, 1000 and 1400 mm, they can be cut as needed (see page 102). PD

99 Distribution 630 A Powerclip busbars Presentation Powerclip busbars are compact and fully insulated (IPxxB). They are supplied ready for installation in the switchboard. There are three and four-pole versions with ratings from 125 to 630 A. Available in four lengths, they can be cut every 150 or 200 mm, depending on the rating. PD DD Composition Powerclip busbars are made up of ETP H12 channelled copper bars with threaded M6 holes every 25 mm. They are mounted on insulated bases and can be cut every 150 or 200 mm, depending on the rating. The ends of the busbars are plugged. Clip-on covers protect against direct contact from the front. The covers can be easily cut for the connections to the devices. Installation The busbars are supplied with supports that screw to the functional uprights of enclosures or to an adapter in a cubicle. They can be cut every 150 or 200 mm, depending on the rating. Electrical characteristics Permissible current of the busbars (A) Rated short-time withstand current Icw (ka rms / 1 second) b rated insulation voltage: v Powerclip 125 A busbars: Ui = 500 V v Powerclip 160 A busbars: Ui = 750 V b impulse withstand voltage: v Powerclip 125/160 A busbars: Uimp = 8 kv. Rated peak withstand current Ipk (kâ) 125 A Powerclip busbars Available in two lengths (450 and 750 mm) in three and four-pole versions. The busbars can be cut to length every 150 mm. They are supplied with clip-on covers that block off the connected cable lugs and can be cut as needed. selection Powerclip busbars 125 A Three-pole L = 450 mm L = 750 mm Four-pole L = 450 mm L = 750 mm Busbar connection Four 125 A connections, L = 230 mm (for NG125, NSA and INS equipped with tunnel terminals) A 35 mm² ferrule for connection to tunnel terminals is crimped to one end. A 45 ring lug is crimped to the other end. 95 mm² tunnel terminals for INS :cat. no (set of 3) cat. no (set of 4) 98

100 Distribution 630 A Powerclip busbars DD /630 A Powerclip busbars Available in two lengths (1000 and 1400 mm) in three and four-pole versions. The busbars can be cut to length every 200 mm. Prefabricated connections are available for the devices. Powerclip busbars 160 A 250 A 400 A 630 A Three-pole L = 1000 mm L = 1400 mm Four-pole L = 1000 mm L = 1400 mm Connection between incoming device and Powerclip busbars Power supply block (with connection) NS NS NS Universal power supply block 100/250 A (without connection) 400/630 A Connection for universal power supply block Vertical NS100/ Vertical NS100/250 in duct Vertical NS400/630 in duct DD DD DD NS400 power supply block (04070) between incoming device and busbars. NS250 power supply block (04060) between busbars and Compact NS A universal power supply block (04061) A connection (04062) between incoming device and busbars. Connection between 200 A Multiclip and Powerclip busbars 200 A 4P connection for Multiclip (supplied with mounting hardware) mm² additional blocks 35 mm² additional blocks 3P P Busbar connection A connections, L = 230 mm (for NSA160) 35 mm² 4P additional blocks (04156). A 45 mm² ferrule for connection to tunnel terminals is crimped to one end. A 45 ring lug is crimped to the other end DD DD Accessories Powerclip tap-off blocks Each block can be used to connect: b one 6 mm² and one 10 mm² cable (04151) b one 16 mm² cables (04152). Equipped with spring terminals. 12 Powerclip tap-off blocks with 6 mm² + 10 mm² terminals Powerclip tap-off blocks with 16 mm² terminals Connection cover Clip-on covers that block off the connected cable lugs and can be cut as needed. They maintain IPxxB with 90 angle lugs and/or cable sizes from 10 to 25 mm². 8 IPxxB covers for Powerclip busbars class mounting hardware Used for electrical connections to the copper bars. Set of 20 CHC M6 x 12 mm screws for Powerclip busbars

101 Distribution 400 A rear busbars Presentation The rear busbars are mounted directly on the uprights of the framework. There are three and four-pole versions with ratings from 160 to 400 A. Available in two lengths, 1000 and 1400 mm, they can be cut as needed. The connection with a Compact or Interpact incoming device occupies two vertical modules (50 mm each). PD Composition Flat, copper bars with threaded M6 holes every 25 mm for connection along the entire length of the busbars. The insulating supports can receive a fifth bar, 15 x 5 mm or 20 x 5 mm, to create an earth bar. Installation The busbars are mounted directly on the functional uprights of enclosures or on an adapter (03595) in a cubicle. Connection b 16 mm² to 50 mm² flexible cables, with crimped lugs b insulated flexible bars (see page 104). Electrical characteristics b rated peak withstand current Ipk (kâ) - 30 kâ for 160 A busbars - 40 kâ for 250 A busbars - 55 kâ for 400 A busbars b rated insulation level Ui = 1000 V Busbar calculation Busbar size and distance between supports The table below indicates: b the size of the bars to be used, depending on the permissible current level in the busbars b the distance between supports, depending on the rated short-time withstand current (Icw). Rating (A) Size of bars (mm) Distance between support centres (mm) Icw (ka rms / 1 s) x x x

102 Distribution 400 A rear busbars DD Busbar selection Copper bars Rating (A) Size of bars (mm) Four copper bars, L = x x x Four copper bars, L = x x x Busbar supports Rear busbar support DD DD Copper bars. Busbar supports. DD Accessories Rear busbar barrier Protects against direct contact with the busbar connections. Supplied with mounting hardware. Rear busbar barrier, H = 100 mm DD A connection For direct supply to comb busbars from the rear busbars in the switchboard. Four 125 A connections, L = 230 mm (for NG125, NSA and INS equipped with tunnel terminals) A 35 mm² ferrule for connection to tunnel terminals is crimped to one end. A 45 ring lug is crimped to the other end. 95 mm² tunnel terminals for INS :cat. no (set of 3) cat. no (set of 4) 160 A connection For direct supply to an NSA160 from the rear busbars in the switchboard A connections L = 230 (for NSA160) A 45 mm² ferrule for connection to tunnel terminals is crimped to one end. A 45 ring lug is crimped to the other end. DD A connection For supply of a 200 A Multiclip distribution block from the rear busbars in the switchboard. Rear busbar connection for 200A Multiclip distribution block Connection between busbars For electrical connections between two sets of rear busbars. 4 copper angle brackets, 250A DD class mounting hardware Set of 20 M6 x 20 bolts (20 bolts + 20 nuts +40 contact washers) Set of 40 M6 x 16 screws (40 screws + 40 contact washers)

103 Distribution 630 A multi-stage busbars Presentation The multi-stage busbars are installed in a 300 mm wide duct. They are particularly useful for distribution to two enclosures on each side of the duct. All connection points are easily accessible from the front. The inclination of the bars facilitates connections and improves cable running. There are three and four-pole versions with ratings from 160 to 630 A. Available in two lengths, 1000 and 1400 mm, they can be cut as needed. PD Composition Flat, copper bars with threaded M6 holes every 25 mm for connection along the entire length of the busbars. There are 8.2 mm diameter holes at each end for supply. The staggered supports are made of an insulating material. An optional, insulating, front barrier is available to protect against direct contact from the front. Installation The busbars are installed in a 300 mm wide duct for the enclosures. Connection b 16 mm² to 50 mm² flexible cables, with crimped lugs b insulated flexible bars (see page 104). Electrical characteristics b rated peak withstand current Ipk (kâ) - 30 kâ for 160 A busbars - 40 kâ for 250 A busbars - 55 kâ for 400 A busbars - 55 kâ for 630 A busbars b rated insulation level Ui = 750 V. Busbar calculation Busbar size and distance between supports The table below indicates: b the size of the bars to be used, depending on the permissible current level in the busbars b the distance between supports, depending on the rated short-time withstand current (Icw). Rating (A) Size of bars (mm) Distance between support centres (mm) Icw (ka rms / 1 s) x x x (1) x 8 (1) Icw (ka rms/0.6 s). 102

104 Distribution 630 A multi-stage busbars DD Busbar selection Copper bars Copper bars Rating (A) Size of bars (mm) Four copper bars, L = 1000 mm Four copper bars, L = 1400 mm x x x x x x x Busbar supports Multi-stage busbar support DD DD DD Accessories Multi-stage busbar barrier Protects against direct contact with the busbar connections from the front. Supplied with mounting hardware. Multi-stage busbar barrier, L = 1500 mm DD Multiclip connection For supply to a 200 A Multiclip. Multi-stage busbar 4P connection for 200 A Multiclip distribution block DD class mounting hardware Set of 20 M6 x 20 bolts (20 bolts + 20 nuts +20 contact washers) Set of 40 M6 x 16 screws (40 screws + 40 contact washers)

105 Distribution Insulated flexible bars DD Presentation Catalogue number selection The insulated flexible bars are tested in a type-tested switchboard environment. Their design takes into account the switchboard architecture where they are often in close proximity to a protection device (circuit breaker or fuse) with significant heat losses. In-depth knowledge of switchboard architecture and the connected devices led to the establishment of a selection table based on the type of device. Flexible bars are 1800 mm long and made of copper with an insulating sheath. Rated insulation level Ui = 1000 V. The sizes for the flexible bars indicated below take into account the heat losses of Schneider devices in a Prisma Plus switchboard. Connection between device and busbars The flexible bars are determined taking into account the connected device, whatever the internal temperature of the switchboard. The bar sizes indicated below take into account the derating curves of devices. Device Size (mm) NS100/ x NS x 3 (1) NS x NS x INS125/ x INS x INS x INS x A Multiclip 20 x Polypact, 3P 32 x Polypact, 4P 32 x Fupact x Fupact x Fupact x (1) To connect a Compact NS250 to Powerclip busbars, use a 24 x 5 mm flexible bar (04746). Connection between busbars Flexible bars are designed for connections between busbars taking into account the following characteristics: a maximum temperature of 60 C inside the switchboard. This corresponds to the average temperature inside a switchboard for an ambient temperature of 35 C b the maximum withstand temperature for the insulating material is 125 C. Ie max. (A) Size (mm) x x x x x x DD

106 105

107 Distribution Overview of distribution blocks PD Rated insulation voltage Ui Rated impulse withstand voltage Uimp Rated operational current Ie (40 C) Rated short-time withstand current Icw Distribloc distribution block 750 V 8 kv 125/160 A Depending on connected device Rated peak withstand current Ipk Depending on connected device PD Polybloc distribution block 750 V 8 kv 250 A Depending on connected device Depending on connected device PD /630 A multi-stage distribution block 750 V 8 kv 160/630 A 10 ka rms / 1 s for 160 A block 13 ka rms / 1 s for 250 A block 20 ka rms / 1 s for 400 A block 25 ka rms / 1 s for 630 A block 30 kâ for 160 and 250 A block 40 kâ for 400 and 630 A block PD A Multiclip distribution block 500 V 6 kv 80 A Depending on connected device Depending on connected device 200 A Multiclip distribution block 750 V 8 kv 200 A PD PD For distribution by comb busbars (63/125 A), strip terminal blocks (80/125 A) or multi-stage distribution blocks (40/125 A), see device catalogue. 106

108 Distribution Overview of distribution blocks Connection capacity Upstream Downstream Installation / comments B b tunnel terminals for 6 to 35 mm² flexible cables (10 to 35 mm² rigid cables) for 125 A Distribloc b prefabricated connections (supplied) for 160 A Distribloc b spring terminals: v 2 outgoers from 1 to 10 v, flexible or rigid v 3 outgoers from 1 to 6 v, flexible or rigid v 7 outgoers from 1 to 4 v, flexible or rigid b tunnel terminals: v 1 outgoer from 4 to 16 v, flexible (4 to 25 v rigid) b modular rail b plain or slotted backplate see page 108 B b directly to the incoming device: Compact NS 100/250, Interpact INS250 b spring terminals: v 6 x 10 v + 3 x 16 mm², flexible or rigid b directly downstream of the incoming device: Compact NS 100/250, Interpact INS250 b modular rail b plain or slotted backplate see page 110 B b cables: v 16 to 50 mm² with crimped lug b flexible bars, see page 104. b 13 outgoers via 50 v max. cables with crimped lugs b screwed to the rear of a wall-mount or floor-standing enclosure b screwed in the 300 mm duct of a wallmount or floor-standing enclosure see page 112 b tunnel terminals for cables y 25 mm² b supplied flexible cables: v 6 and 10 mm² b clipped onto rear of modular rail b screwed to plain or slotted backplate see page 114 B b via prefabricated connections from rear busbars b via prefabricated connections from Powerclip busbars b 50 mm² cables with crimped lugs b 20 x 3 mm flexible bars, see page 104 b supplied flexible cables: v 10 mm² see page 47 see page

109 Distribution Distribloc distribution block DD PD DD General Cable connection. Distribloc distribution block PD Downstream circuits are connected from the front, to spring terminals. Contact pressure automatically adapts to the size of the conductor. It does not depend on the operator. Contacts are insensitive to vibrations and thermal variations. Only one cable (flexible or rigid, without a metal ferrule) can be inserted in a spring terminal. Degree of protection: IPxxB. Advantages b a reliable electrical connection, no maintenance required (tightness guaranteed over time) b very fast connection b easy phase balancing b rewiring is very easy if the switchboard is expanded or modified. The four-pole distribution block is made up of: b a fully insulated, one-piece distribution block complying with the degree of protection IPxxB (protection against direct contacts) b a modular cover. The design of the front (45 mm nose) blends perfectly into a row comprising modular devices. 125 A Distribloc distribution block A Distribloc distribution block + connection Electrical characteristics b rated insulation level: Ui = 750 V b rated operational current Ie (40 C): v 125 A for the 125 A Distribloc v 160 A for the 160 A Distribloc with its prefabricated connection for INS160 or NSA160 b short-circuit withstand current: the reinforced breaking capacity due to cascading in circuit-breaker combinations is maintained. The worst-case situations have been tested. b complies with the low-voltage device standard IEC and/or IEC b impulse withstand voltage Uimp = 8 kv. Supply b tunnel terminal on 125 A Distribloc 125 for 6 to 35 v flexible cables (10 to 35 v rigid cables) b the 160 A Distribloc is supplied with a prefabricated flexible connection. It is designed for an INS100/160 or NSA160 switch-disconnector, installed on the left or right. Distribution (125 and 160 A Distribloc) b spring terminals: v 2 outgoers from 1 to 10 v, flexible or rigid v 3 outgoers from 1 to 6 v, flexible or rigid v 7 outgoers from 1 to 4 v, flexible or rigid b tunnel terminals: v 1 outgoer from 4 to 16 v, flexible (4 to 25 v rigid) Supply b an identification label b adhesive labels for phase identification b a prefabricated flexible connection for the INS160 or NSA160 (160 A Distribloc only). DD

110 Distribution Distribloc distribution block Installation b clipped onto a modular rail b width occupied is 12 modules (9 mm each) b screwed to plain or slotted backplate. Distances between centres = 100 x 75 mm. Dimensions DD PD DD A connection Set of four flexible connections, 35 v,, L = 210 mm. To supply a 125 A Distribloc from an NG125 or an INS NG-INS125 connections for Distribloc DD

111 Distribution Polybloc distribution block DD General Downstream circuits are connected from the front, without screws, to spring terminals. Contact pressure automatically adapts to the size of the conductor (minimum size = 1 mm 2 ). Contacts are insensitive to vibrations and thermal variations. Only one cable (flexible or rigid, without a metal ferrule) can be inserted in a spring terminal. Degree of protection: IPxxB. Advantages of spring terminals b a reliable electrical connection, no maintenance required b the fast connections make phase balancing very easy. b rewiring is very easy if the switchboard is expanded or modified. PD A Polybloc distribution block Applications The Polybloc distribution block is designed for installation directly downstream of Compact circuit breakers and Interpact switch-disconnectors devices up to 250 A. It can be rapidly mounted in the horizontal position. Electrical connections are made directly to the device terminals. It has the same width as the devices and does not take up any additional space in the switchboard. The connection terminals are slanted to facilitate cable entry and not exceed the bending radius of the flexible and rigid cables. selection Polybloc distribution block, 3P, 250 A Polybloc distribution block, 4P, 250 A DD Horizontally mounted Polybloc in a wall-mount enclosure. Electrical characteristics The electrical characteristics are perfectly compatible with the connected devices. Neither the temperature derating curves nor the performance levels of the circuit breakers and switch-disconnectors are altered. b rated insulation level Ui = 750 V b short-circuit withstand current: the reinforced breaking capacity due to cascading in circuit-breaker combinations is maintained. The worst-case situations have been tested. impulse withstand voltage Uimp = 8 kv. Supply Directly to the terminals of the Compact NS and Interpact INS devices up to 250 A. Distribution Via cables, up to six 10 mm² cables and three 16 mm² cables per phase. Installation Directly on the mounting plates of horizontally mounted Compact NS100/250 and Interpact INS250 devices in the enclosures. It can also be mounted downstream of vertically mounted Compact NS100/250 and Interpact INS250 devices in the enclosures. In this case, the Polybloc is mounted on a depth-adjustable modular rail (03002 ) or (03402 System P). Dimensions H (mm) L (mm) P (mm) Polybloc, 3P Polybloc, 4P DD

112 Distribution Polybloc distribution block DD mm² additional blocks These blocks with screw terminals can be mounted on the 250 A Polybloc for connection of two 35 mm² cables per phase. 35 mm² 3P additional blocks (3 blocks) mm² 4P additional blocks (4 blocks) DD Additional blocks with a Polybloc distribution block. DD DD A Polybloc distribution block The 160 A Polybloc is made up of individual elements that can be used alone or with others to make two-pole, three-pole or four-pole distribution blocks. Mounting is very fast. It clips onto a modular rail and is supplied by cables via a tunnel terminal. The connection spring terminals are slanted to facilitate cable entry and bending of the flexible and rigid cables. It is supplied with a cover that also guides the cables. Three 160 A Polybloc distribution blocks in the vertical position on a modular rail, supplied by an NG A Polybloc distribution block in a front plate cut-out. selection Polybloc distribution block, 1P, 160 A Sold in sets of 12. Electrical characteristics b rated insulation level Ui = 750 V b short-circuit withstand current: the reinforced breaking capacity due to cascading in circuit-breaker combinations is maintained. The worst-case situations were tested. The electrical characteristics are perfectly compatible with the connected devices. Neither the temperature derating curves nor the performance levels of the circuit breakers and switch-disconnectors are altered. b impulse withstand voltage Uimp = 8 kv. Supply Direct to a tunnel terminal, for cables up to 70 mm². Distribution Via cables, up to six 16 mm² cables. Installation The blocks clip onto a modular rail. Dimensions DD

113 Distribution 160/630 A multi-stage distribution block PD /630 A four-pole multi-stage distribution block The distribution block can be installed horizontally in the device zone or vertically in the 300 mm wide duct of wall-mount and floor-standing enclosures. The distribution block is made up of: b two staggered supports made of an insulating material b four slanted copper bars with holes every 25 mm v 13 threaded M6 holes for outgoers v four 12.2 mm diameter holes to supply the distribution block. It is supplied with: b M6 hardware b one IPxxB insulating barrier for the front. selection Multi-stage distri. block Size of bars (mm) 160 A Distribloc (40 C) 15 x A Distribloc (40 C) 20 x A Distribloc (40 C) 32 x A Distribloc (40 C) 32 x DD Electrical characteristics b rated operational current Ie (40 C): v 160 A for distribution block v 250 A for distribution block v 400 A for distribution block v 630 A for distribution block b rated insulation level Ui = 750 V b rated short-time withstand current Icw: v 10 ka rms / 1 s for 160 A block v 13 ka rms / 1 s for 250 A block v 20 ka rms / 1 s for 400 A block v 25 ka rms / 1 s for 630 A block b rated peak withstand current Ipk: v 30 kâ for 160 A block v 30 kâ for 250 A block v 40 kâ for 400 A block v 40 kâ for 630 A block b impulse withstand voltage Uimp = 8 kv. Supply b 16 mm 2 to 50 mm 2 cables with crimped lugs b 20 x 2 mm flexible bars for NS100/160 b 20 x 3 mm flexible bars for NS250 b 32 x 5 mm flexible bars for NS400 b 32 x 8 mm flexible bars for NS630. Distribution 13 outgoers per phase, max. 50 mm 2. Installation b screwed horizontally onto the functional uprights of wall-mount and floor-standing enclosures b screwed vertically onto the functional uprights of the 300 mm wide duct b screwed to plain or slotted backplate. DD DD DD

114 113

115 Distribution Multiclip distribution block DD PD DD General Cable connection. 63/80 A Multiclip distribution blocks For connections, the distribution block uses a proven technique, i.e. spring terminals. Downstream circuits are connected from the front, without screws, to spring terminals. Contact pressure does not depend on the operator. It automatically adapts to the size of the conductor (minimum size = 1mm²). Contacts are insensitive to vibrations and thermal variations. Only one cable (flexible or rigid, without a metal ferrule) can be inserted in a spring terminal. Degree of protection: IPxxB. Advantages b a reliable electrical connection, no maintenance required (tightness guaranteed over time) b the fast connections make phase balancing very easy. b rewiring is very easy if the switchboard is expanded or modified. Application Distribution over half or full rows of modular devices. It is generally supplied by a device at the head of a group of outgoers (NG125, INS, C60, etc.). selection 80 A Multiclip distribution block, 4P A Multiclip distribution block, 4P, 1/2 row Electrical characteristics b rated insulation level Ui = 500 V b impulse withstand voltage Uimp = 6 kv b short-circuit withstand current: the reinforced breaking capacity due to cascading in circuit-breaker combinations is maintained. The worst-case situations have been tested. b 63/80 A Multiclip distribution blocks: v 4 mm² cable outgoer: Imax = 32 A v 6 mm² cable outgoer: Imax = 40 A v two 6 mm² cables: Imax = 63 A. Supply Via tunnel terminals up to 25 mm², generally from a device supplying a group of outgoers. The tunnel terminals are positioned to facilitate cable entry and screw tightening. They are designed for cables arriving from the top or bottom. Distribution b for the full-row Multiclip, 4P (04004), each phase offers: v 2 connection points for 6 mm² max. cable v 7 connection points for 4 mm² max. cable the neutral offers: v 4 connection points for 6 mm² max. cable v 13 connection points for 4mm² max. cable b for the half-row Multiclip, 4P (04008), each phase offers: v 2 connection points for 6 mm² max. cable v 2 connection points for 4 mm² max. cable the neutral offers: v 4 connection points for 6 mm² max. cable v 4 connection points for 4 mm² max. cable Each connection point can receive a single cable, either flexible or rigid. Installation b clipped onto the rear of modular rail b screwed to plain or slotted backplate DD DD Half-row Multiclip distribution block supplied by an INS switch-disconnector. Multiclip distribution block supplied by a Vigi NG125 circuit breaker. Supplied with 100 mm long bared copper connections b for full-row Multiclip (04004): v 2 sets of ten 4 mm² connections + 1 set of six 6 mm² connections b for half-row Multiclip (04008): v 1 set of ten 4 mm² connections + 1 set of six 6 mm² connections. 114

Prisma Plus System P Cubicles up to 4000 A

Prisma Plus System P Cubicles up to 4000 A Low Voltage electric distribution Prisma Plus System P Cubicles up to 4000 A Catalogue 2012 Presentation PD390180_SE.eps IP30/31/55 cubicles b Applications: v indoor cubicles for main or subdistribution

More information

Multi 9 switchgear NSA, INS, NG125

Multi 9 switchgear NSA, INS, NG125 N interpact INS 125 5 8 I. ON Installation and connection in the switchboard Multi 9 switchgear NSA, INS, NG125 051279-70% Description of device number per row (modules = 9 mm) E37025(MGA+BT) Multi 9 switchgear

More information

Pan assemblies and installation accessories

Pan assemblies and installation accessories Contents Section 10 Pan assemblies and installation accessories SP&N pan assemblies 124 SP&N door and cover 124 TP&N pan assemblies 125 TP&N door and cover 125 Multiclip busbar and Polybloc 126 Comb busbars

More information

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation. Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation

More information

XL 4000 metal free-standing enclosures and cable compartments

XL 4000 metal free-standing enclosures and cable compartments 87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL metal free-standing enclosures and CONTENTS PAGE 1. General characteristics...1 2. Range...2 3. Overall dimensions...2 4. Equipment...3

More information

Compact NS 100/400 in the duct Interpact INS 250/400 in the duct Interpact INV 250/400 in the duct

Compact NS 100/400 in the duct Interpact INS 250/400 in the duct Interpact INV 250/400 in the duct push to trip Io Ir.8.9.9.93.7 1.88.95.63.85.98.5.8 1 Ir Im xin xio Ir Im a a.7.63.5.8.9 1 xin Io push to trip Ir.9.93.88.95.85.98.8 1 xio alarm 90 105 alarm 90 105 Im 5 6 4 7 3 8 2 10 xir Im 5 6 4 7 3

More information

Low Voltage electrical distribution Catalogue Prisma PH

Low Voltage electrical distribution Catalogue Prisma PH Low Voltage electrical distribution Catalogue 2014 Prisma PH Prisma PH Contents Index 2 Electrical switchboards... Up to 4000 A 4 Prisma PH functional system 6 Switchgears 7 Linergy LGYE 8 Horizontal

More information

Build electrical installations more efficiently. Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A

Build electrical installations more efficiently. Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A Build electrical installations more efficiently Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A Develop your business efficiency w Switchboards that are safe

More information

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional

More information

Build electrical installations more efficiently. Prisma G Simple, functional systems for safe, upgradeable LV switchboards up to 630 A

Build electrical installations more efficiently. Prisma G Simple, functional systems for safe, upgradeable LV switchboards up to 630 A Build electrical installations more efficiently Prisma G Simple, functional systems for safe, upgradeable LV switchboards up to 630 A Develop your business efficiency wit Switchboards that are safe With

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

ALPHA SIMBOX Small Distribution Boards

ALPHA SIMBOX Small Distribution Boards ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional

More information

The right solution for every home

The right solution for every home Domae Household switchboards The right solution for every home Household guide 2002 Building a New Electric World. Household switchboards Domae The right solution for every home Household guide 2002 Building

More information

Argenta W A L L M O U N T I N G M E T A L C A B I N E T S

Argenta W A L L M O U N T I N G M E T A L C A B I N E T S Argenta W A L L M O U N T I N G M E T A L C A B I N E T S The ARGENTA Series is a group of metal enclosures used to house on the inside electrical or electronic switchgear, controlgear and equipment necessary

More information

E-KAB N E SERIES WALL- MOUNTED DISTRIBUTION SWITCHBOARDS

E-KAB N E SERIES WALL- MOUNTED DISTRIBUTION SWITCHBOARDS E-KAB N E SERIES WALL- MOUNTED DISTRIBUTION SWITCHBOARDS DUVAR T P TES SAT KAB NLER www.eae-et.com.tr EAE Elektroteknik A.S. reserves rights to make changes within this document without prior notice. CONTENTS

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

Flatwall. Aesthetic value and functional integration for home automation

Flatwall. Aesthetic value and functional integration for home automation Flatwall Aesthetic value and functional integration for home automation 2 MyHOME FLATWALL Index 2-13 General features 14-33 General rules for installation 34-39 Catalogue MyHOME FLATWALL 240-270 2 MyHOME

More information

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type

More information

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA for ic60, iid, idpn Vigi, isw-na, RCA and ARA b The electrical auxiliaries are combined with ic60 circuit breakers, iid residual current circuit breakers, remote tripping switch disconnector isw-na, RCA

More information

References. References. Rating (A) Référence

References. References. Rating (A) Référence DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle

More information

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip Product Managers and dedicated Business Development Managers are available to assist with all your enquiries. Technical presentations (Forms of Separation, Discrimination etc) available Site response capability

More information

Linear Luminaire with LED Series 6012/5

Linear Luminaire with LED Series 6012/5 > For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

Kaedra system PB102271

Kaedra system PB102271 PB102271 Index General presentation 72 Selection guide 75 Enclosures for sockets 76 Enclosures with interface 77 Enclosures for modular devices 78 Universal enclosures 79 The functional plates 80 Accessories

More information

- With PE/N terminals - For flush mounting devices with size 1 to DIN For circuit-breaker NZM... - Switch-disconnector N...

- With PE/N terminals - For flush mounting devices with size 1 to DIN For circuit-breaker NZM... - Switch-disconnector N... Distribution board enclosure with gland plates fitted KST... CI: Page 20/6 KST...: CI: Page 20/10 - With PE/N terminals - For flush mounting devices with size 1 to DIN 43880 Page 20/31 - For circuit-breaker

More information

Linear Luminaire with LED Series 6412/5

Linear Luminaire with LED Series 6412/5 > For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security aesthetics c Elegant and robust design. c Colour easy to integrate in any environment. weatherproof & versatile enclosures multi-functional c Different solutions for: industrial control, electrical distribution,

More information

NEW Titan II A & B Distribution Boards

NEW Titan II A & B Distribution Boards A Type Board Specification: Powder Coated Epoxy Resin Finish RAL 7035 Designed and built in the UK to BS EN 60439 Maximum busbar rating 125A Degree of protection IP3X to BS EN 60529 Blank gland plates

More information

for a perfect electrical installation. The range of rail-mounted terminal blocks

for a perfect electrical installation. The range of rail-mounted terminal blocks The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal

More information

Merlin Gerin LV switch-disconnectors Interpact 40 to 2500A

Merlin Gerin LV switch-disconnectors Interpact 40 to 2500A erlin Gerin LV switch-disconnectors Interpact 40 to 2500A 2 LV switch-disconnectors Interpact from 40 to 2500 A 4 Typical low-voltage applications 6 Compact from 80 to 1250 A 7 asterpact from 800 to 6300

More information

CONTROL PANEL WIRING SPECIFICATIONS

CONTROL PANEL WIRING SPECIFICATIONS CONTROL PANEL WIRING ISSUE STATUS FIRST REV DESCRIPTION DATE 001 1 ST ISSUE 22/04/2014 002 1 ST AMMENDMENT 10/03/2017 003 2 ND AMMENDMENT 08/09/2017 THIS DOCUMENT IS DESIGNED TO COVER ALL APPLICATIONS,

More information

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment) 25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

TP&N DISTRIBUTION BOARD TYPE B RANGE

TP&N DISTRIBUTION BOARD TYPE B RANGE GROUP Now included in the range: Extension Boxes Metering Kits Surge Suppression and more! TP&N DISTRIBUTION BOARD TYPE B RANGE A comprehensive distribution board range for modern commercial & industrial

More information

Interpact Switch-disconnectors INS/INV40 to 2500 A. INS/INV Standard version with black handle - Fixed /FC

Interpact Switch-disconnectors INS/INV40 to 2500 A. INS/INV Standard version with black handle - Fixed /FC 28901 2890 28905 28909 28911 2891 116 1167 1169 1171 117 1175 171 159 161 16 165 167 169 111 115 11 117 119 1151 115 1155 Load s Interpact Switch-disconnectors INS/INV0 to 2500 A The Interpact INS/INV

More information

Weatherproof enclosures for all corrosive environments

Weatherproof enclosures for all corrosive environments IP 66 MRIN INETS N ENLOSURES >>> Marina cabinets polyester - IP 66 - IK 10 www.klinkmann.com Weatherproof enclosures for all corrosive environments 362 56 362 76 Technical characteristics (p. 289) IP 66

More information

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating.

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating. 19 Stand Alone Cabinet with IP65 Rating www.apw.eu.com Overview Material specification Frame: Steel 2.0 mm Panel mounting angles and reducing channels: Steel 2.0 mm Panel mount supports: Steel 1.5 mm Side

More information

Consumer units IP66 >> M135 DOMINO IP66 Series [enclosure] 672.

Consumer units IP66 >> M135 DOMINO IP66 Series [enclosure] 672. 1 Empty enclosures DOMINO IP66 Series Consumer units IP66 >> M135 INDUSTRY 2 DIN 2 3 4 CONSUMER UNIT Modularity No. Modules Dimension Power IP66 M135 2 MOD. 135x76x102mm 6W 2002 1/24 DOMINO IP66 Series

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

CABINETS & ENCLOSURES FOR PREPAYMENT METERS

CABINETS & ENCLOSURES FOR PREPAYMENT METERS CABINETS & ENCLOSURES FOR PREPAYMENT METERS Solutions designed according to customer need, conceived for every type of prepayment meter: > Meters with keypad data entry terminal > Split meters with remote

More information

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry 36 Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry Assembly Assembly of modular terminal blocks to terminal strips Mounting of an end plate screw fixing CAGE

More information

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety CSPe Type Small Version CAe Type Non-Hinged Version CAe Type Hinged Versions Compliance Data: ATEX - IECEx: Zone 1 & 1 & ATEX II GD IECEx CE Ex e II T6 to T Ex td A1 T75 C to T95 C Ex ia IIC; Ex ib IIC

More information

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways.

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways. Doepke The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways. Designed to meet BSEN60439-3 these easy to install consumer units accept the

More information

Distribution Systems ALPHA. Answers for infrastructure and cities. Edition Catalog LV 51

Distribution Systems ALPHA. Answers for infrastructure and cities. Edition Catalog LV 51 Distribution Systems ALPHA Catalog LV 51 Edition 2013 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10.1 Electrical Installation Technology SENTRON Protection,

More information

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb_cat Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle Direct handle acces_147_a_2_cat

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

pro du c t n ote System pro E control IS2 New Range Extension H1400 and H1600

pro du c t n ote System pro E control IS2 New Range Extension H1400 and H1600 pro du c t n ote System pro E control IS2 New Range Extension H1400 and H1600 2 System pro E control IS2 New Range extension H1400 and H1600 System pro E control IS2 New Range Extension H1400 and H1600

More information

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its Sentry 2 TECHNICAL HOTLINE +44 (0)268 563720 The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its environment. The curved lines and slim-line appearance

More information

Low Voltage Catalogue Prisma G. Wall-mounted and floor standing enclosures for Electrical Distribution up to 630 A

Low Voltage Catalogue Prisma G. Wall-mounted and floor standing enclosures for Electrical Distribution up to 630 A Low Voltage Catalogue 2013 Prisma G Wall-mounted and floor standing enclosures for Electrical Distribution up to 630 A Overview To respond to increasing building requirements Improve the continuity of

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

resistance for high requirement

resistance for high requirement HEVY DUTY FLOOR OXES >>> NEW High resistance for high requirement For highly frequented areas, requiring important mechanical resistance and/or washing down. heavy duty in-screed floor box s 896 83 896

More information

Free-Stand Disconnects and Accessories

Free-Stand Disconnects and Accessories 763.422.2600 Spec-00067 L763.422.2211 Free-Stand Preferred-Cutout s Free-Stand s and Accessories Free-Stand Preferred-Cutout s Free-Stand s and Accessories Free-Stand Enclosure, Type 1 INDUSTRY STANDARDS

More information

EMS CX 3 - State and control module for Latching relays and Contactors

EMS CX 3 - State and control module for Latching relays and Contactors 87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax: 05 55 06 88 88 EMS CX 3 - State and control module Contents Pages 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation -

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

EMS CX 3 - State and control module for Latching relays and Contactors

EMS CX 3 - State and control module for Latching relays and Contactors LEGRAND - BP30076 87045 LIMOGES CEDEX FRANCE Telephone: 05 55 06 87 87 Fax: 05 55 06 88 88 Contents Pages 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Small enclosure golf VF & VS

Small enclosure golf VF & VS Small enclosure golf VF & VS The enclosure for flush or surface mounting installation When building or renovating residential buildings, compact solutions are often required for electrical installations.

More information

DistriTon. Enclosures. Steel-plastic RZA Steel-sheet RZB Plastic RZG Plastic IP65 RZI

DistriTon. Enclosures. Steel-plastic RZA Steel-sheet RZB Plastic RZG Plastic IP65 RZI Steel-plastic RZA Steel-sheet RZB Plastic RZG Plastic IP65 RZI Enhanced space Large number of terminals Invented for electricians Main advantages Steel-plastic RZA Enhanced space Large number of terminals

More information

Pragma. Doors reference if necessary. references. In perfect harmony. + customiser

Pragma. Doors reference if necessary. references. In perfect harmony. + customiser modular surface mounted enclosure Robustness, aesthetic, ergonomics a range of enclosures designed to appeal a harmonious solution. Which enclosure fits you best? Type Rows Modules capacity I(n) number

More information

LSFC Power Factor Correction Systems

LSFC Power Factor Correction Systems LSFC Ready to connect, automatic in sheet steel cabinets for floor installation. Suitable for networks without harmonic distortion. Power Range: 100 to 00 kvar Modular construction in freestanding sheet

More information

Protect Circuit Protection

Protect Circuit Protection Circuit Protection Product Catalogue 2018 Protect Circuit Protection Deta s new range of domestic Circuit Protection provides a high quality and cost effective solution, perfect for both new build and

More information

PROLINE. Wall mounted cases FOR ROBUST INDUSTRIAL ENVIRONMENTS UP TO IP 66. Epcase OVERVIEW MAIN KATALOG

PROLINE. Wall mounted cases FOR ROBUST INDUSTRIAL ENVIRONMENTS UP TO IP 66. Epcase OVERVIEW MAIN KATALOG Wall Mounted Case PROLINE Main Catalogue Wall mounted cases OVERVIEW FOR ROBUST INDUSTRIAL ENVIRONMENTS UP TO IP 66 MAIN KATALOG Cabinets....... 1 Wall mounted cases......... 2 Accessories for cabinets

More information

Dorman Smith Loadbank 125 MCCB Panel Boards

Dorman Smith Loadbank 125 MCCB Panel Boards Dorman Smith Loadbank 125 MCCB Panel Boards Section 3 MCCB Panel Boards Loadbank 125 Range (250A and 400A Ratings) Overview Key Features ASTA certified busbars with a short circuit rating of 25kA for 1

More information

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

19 TiRAX cabinet system. from page 3. 19 NETcell cabinet system from page 31. Open 19 racks from page 43 9" TiRAX cabinet system from page 9" NETcell cabinet system from page Open 9" racks from page Wall-mounting/stand-alone distribution systems from page 5 Wall-mounting enclosure systems from page 6 Air

More information

Probably the fastest enclosure in the world

Probably the fastest enclosure in the world 95 9 enclosure system Probably the fastest enclosure in the world Sample configuration tools required no no tools required Vitaro can be assembled within less than 60 seconds. 00:00 00:0 00:08 00: 00:5

More information

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories / SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in

More information

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution.

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution. Technical Datasheet Tier Power Systems, Inc. iq Series UL 1558 Switchgear Tier Power Systems iq Series is a leader in switchgear technology. iq Series provides advanced power distribution technology and

More information

Vertiv VR Rack 1.0 GENERAL

Vertiv VR Rack 1.0 GENERAL 1.1 SUMMARY Vertiv VR Rack Guide Specifications 1.0 GENERAL This specification defines the mechanical characteristics and requirements for the Vertiv VR Rack. A series of adaptive and scalable electronic

More information

LOADSTAR MCBs AND DISTRIBUTION BOARDS

LOADSTAR MCBs AND DISTRIBUTION BOARDS MCBS AND DISTRIBUTION BOARDS Devices 6kA and 10kA Ranges 6A to 63A Single, Double and Triple Pole Type B, C & D Single and Double module RCBOs 35mm 2 Cable Terminals BS EN 60898 System 125A and 250A TP

More information

07. har-link INTERFACE CONNECTORS

07. har-link INTERFACE CONNECTORS . INTERFACE CONNECTORS The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

89SV80/R1200. Mechanical Components. Marshalling rack cubicle with double-sided MTP-Elements. Application. Description. Cubicle

89SV80/R1200. Mechanical Components. Marshalling rack cubicle with double-sided MTP-Elements. Application. Description. Cubicle Module Description Procontrol P Mechanical Components Marshalling rack cubicle with double-sided MTP-Elements 1KGD 400 012 E, Edition 01/2010 89SV80/R1200 Application The marshalling rack cubicle has the

More information

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,

More information

ict contactors EN 61095, IEC 1095 Interference

ict contactors EN 61095, IEC 1095 Interference ict contactors DB23399 DB669 DB06604 Country approval pictograms EN 6095, IEC 095 ict contactors are available in two versions: b Contactors without manually-operated b Contactors with manually-operated.

More information

Free-Standing Type 12 Enclosures

Free-Standing Type 12 Enclosures Type 12 Enclosures Application Designed to protect electrical and electronic controls, components, and instruments in typical industrial environments. The UL Type 12 rating protects enclosed equipment

More information

modlink msdd Front panel interfaces

modlink msdd Front panel interfaces Tight and with full visibility The connecting mechanism of the Modlink MSDD with integrated locking mechanism allows the components to be used under protection class IP65. This protection class prevents

More information

SERVICE PARTS MANUAL

SERVICE PARTS MANUAL SERVICE PARTS MANUAL DX SERIES SNOW PLOW FOR SERIES SNOW PLOWS SERIAL NUMBERS AFTER DX0000 00 Sno-Way International 0G TABLE OF CONTENTS Page HYDRAULIC SYSTEM (DX)... POWER PACK FRAME... 3 BLADES... LIFT

More information

InForm Superstructures

InForm Superstructures Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices

More information

Switches and Indicators 84

Switches and Indicators 84 Switches and Indicators 84 84 Switches and Indicators Index Series 84 Description Page 177 Product Assembly Page 178 Mounting Instruction Page 179 Product Range - pushbuttons for flush mounting - accessories

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

Invicta 3 Panelboards

Invicta 3 Panelboards Invicta 3 Panelboards The new range of Invicta 3 panelboards are our easiest boards ever to install, and will help you meet the needs of Part L2 of the Building Regulations. The last few years have seen

More information

Defender B Board. Make The Switch

Defender B Board. Make The Switch Defender B Board Make The Switch Defender B Board 1.2mm Electro Galvanised Sheet Steel Tested to BS EN61439-3 Busbar Short Time Withstand Rating Icw 20kA 0.25s Tested at 35 C Ambient Tin Plated Busbar,

More information

W DATA SHEET: FREE-STANDING DATA ENCLOSURES DS

W DATA SHEET: FREE-STANDING DATA ENCLOSURES DS W DATA SHEET: FREE-STANDING DATA ENCLOSURES DS w TECHNICAL DATA Welded powder-coated sheet steel skeleton Heights: 15, 18, 22, 27, 32, 37, 42, 45 and 47 U Widths: 600 and 800 mm Depths: 400, 600, 800,

More information

Manual source-changeover systems Possible combinations

Manual source-changeover systems Possible combinations Manual source-changeoer systems Possile cominations A manual source-changeoer system can e installed on two or three manually-operated and mechanically interlocked circuit reakers or switch-disconnectors.

More information

IT power distribution Power distribution units (PDU) Basic. Versions available:

IT power distribution Power distribution units (PDU) Basic. Versions available: IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,

More information

Consumer Units IP Rated & Metal Enclosures Devices - MCBs, RCBOs & RCDs. Control Devices & Accessories

Consumer Units IP Rated & Metal Enclosures Devices - MCBs, RCBOs & RCDs. Control Devices & Accessories Consumer Units IP Rated & Metal Enclosures Devices MCBs, RCBOs & RCDs Control Devices & Accessories Modern stylish design with a profile that matches Nexus wiring accessories Quality designed in Flexibility

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

EMEA. Product Catalog. RackLine. AT&T Rack & Enclosure LAN Cabling Products. AT&T Cabling Systems

EMEA. Product Catalog. RackLine. AT&T Rack & Enclosure LAN Cabling Products. AT&T Cabling Systems EMEA Product Catalog 2014 AT&T Rack & Enclosure LAN Cabling Products AT&T Cabling Systems provide complete enterprise solutions and state-of-the-art LAN cabling components for all needs. AT&T Cabling Systems

More information

AMIGO-Distribution Boards for flush mounting

AMIGO-Distribution Boards for flush mounting AMIGO-Distribution Boards for flush mounting Flush mounting distribution boards Distribution boards for cavity partition walls Accessories Now also available with screw-less terminals The AMIGO small flush

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

C60 multi-standard range

C60 multi-standard range Low voltage C60 multi-standard range Catalogue 07/2014 C60 multi-standard range Summary Presentation Panorama of the C60 multi-standard range CM907017E 2 Circuit protection Circuit breaker C60 UL 489

More information

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS - Made in Turkey With Pride! HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS, the only Turkish manufacturer of state-of-the-art LAN cabling systems

More information

Powerpact 4 panelboards Panelboards and incoming devices Panelboards

Powerpact 4 panelboards Panelboards and incoming devices Panelboards Panelboards and incoming devices Panelboards Panelboards MG25C2 250A 13 way powerboard 506.76 MG25C4 250A 17 way powerboard 534.00 MG2C5 250A 5 way panelboard 620.33 MG2C7 250A 7 way panelboard 650.83

More information

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing D-Net CABINETS D-Net cabinets are a versatile racking system suitable for housing networking and various structured cabling components. D-Net Cabinets are manufactured in Taiwan in compliance with ISO9001:2000

More information

the Santon FCS-type switch Disconnect Superior Switch Solutions

the Santon FCS-type switch Disconnect Superior Switch Solutions the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal

More information

Model QRS CPVS

Model QRS CPVS SPARE PARTS LIST EN CP COMPRESSOR Model QRS 0-5 - 0 CPVS 0-5 - 0 6 05 50 65 KEY - Door Panel: 655900 Lock - Door Panel: 005076 QRS 0 CONTENTS Title Page MAINTENANCE HOW TO READ THIS SPARE PART LIST? KIT

More information

OZLINX Solutions Australia Pty Ltd 21 Ayton Street, Sunshine North, Melbourne VIC3020 Australia Ph: Fax:

OZLINX Solutions Australia Pty Ltd 21 Ayton Street, Sunshine North, Melbourne VIC3020 Australia Ph: Fax: OZLINX Solutions Australia Pty Ltd 21 Ayton Street, Sunshine North, Melbourne VIC3020 Australia Ph: +61 3 93102440 Fax: +61 3 93102441 www.ozlinx.com OZLINX Cabinets OZLINX Cabinets OZLINX cabinets combine

More information

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals Technical Data Type: KS 4401 KS 4402 KS 4403 KS 4461 KS 4404 KS 440 KS 4406 Article number * ) : 00636 00637 0063987 00614

More information

Make IT easy: The new TS IT rack

Make IT easy: The new TS IT rack Make IT easy: The new TS IT rack The new TS IT rack. A new global standard for network and server equipment. At CeBIT 202, Rittal unveiled a newly developed rack system which is set to redefine the global

More information

02 / The new N/PE Quick-terminals For any type of distribution systems

02 / The new N/PE Quick-terminals For any type of distribution systems 02 / 2013 The new N/PE Quick-terminals For any type of distribution systems 04 2012 Standardised, future-oriented and flexible The new N/PE Quick-terminals from STRIEBEL & JOHN are designed for the things

More information