Radio-Read Filter ALLOWS TWO METER-READING DEVICES TO CONCURRENTLY READ A WATER METER
|
|
- Joseph Shepherd
- 5 years ago
- Views:
Transcription
1 Radio-Read Filter ALLOWS TWO -READING DEVICES TO CONCURRENTLY READ A WATER 2 YEAR WARRANTY DIN-RAIL-MOUNT VERSION WALL-MOUNT VERSION Wiring Diagrams 20 June The RRF-D and RRF-W are designed for applications where the EtherMeter is one of the endpoints. If an EtherMeter is not to be part of the application, it is the responsibility of the user to verify compatibility. 2 See the Compatibility Matrix at for full compatibility details. 3 The RRF-D and RRF-W are rated for the following environmental conditions: Temperature: -30C to +85C. Relative Humidity: 5% to 95%, Non-Condensing. 4 The RRF-D and RRF-W are not pit-compatible unless potted by user. 5 The REMOTE-CONTROL(BOOST) wire may not be required in all instances. Verification testing is recommended before removing the REMOTE-CONTROL(BOOST) wire. 6 In Applications where an EtherMeter is used in conjunction with a third-party meter interface, the EtherMeter should always be wired to RRF terminals 1,2,3; and the third-party interface should be wired to RRF terminals 7,8,9. 7 The RRF-W should be mounted with the 3 cable glands pointing downward. AUTHORIZED SCADAMETRICS RESELLER SCADAmetrics St. Louis, Missouri USA
2 1
3 PWR+ AUX3+ RESERVED AIN1+ AIN2+ AUX1+ AUX2+ PWR- AUX3- AIN1- AIN2- AUX1- AUX2- M1-CMN M2-CMN 485-A 485-B 485-CMN PARALLEL AUTOMATION SYSTEM / SYSTEM HOOKUP FOR ONE (1) SENSUS-COMPATIBLE EtherMeter -Industrial Interface PRODUCT/MAC ID LABEL EM-100 EtherMeter PATENTED MAC ID: 00-1D-C8-nn-nn-nn FLASH PROGRAMMING HEADER LCD DISPLAY PWR TxD AIN1: AIN2: RxD XMT JP1 JP2 S ETUP 120 OHM RS-232 ON DCD LCD ADJ RUN RS-485 NO OFF CONTROL SENSUS-COMPATIBLE 2
4 PWR+ AUX3+ RESERVED AIN1+ AIN2+ AUX1+ AUX2+ PWR- AUX3- AIN1- AIN2- AUX1- AUX2- M1-CMN M2-CMN 485-A 485-B 485-CMN PARALLEL AUTOMATION SYSTEM / SYSTEM HOOKUP FOR ONE (1) NEPTUNE EtherMeter -Industrial Interface PRODUCT/MAC ID LABEL EM-100 EtherMeter PATENTED MAC ID: 00-1D-C8-nn-nn-nn FLASH PROGRAMMING HEADER LCD DISPLAY PWR TxD AIN1: AIN2: RxD XMT JP1 JP2 S ETUP 120 OHM RS-232 ON DCD LCD ADJ RUN RS-485 NO OFF CONTROL NEPTUNE 3
5 PWR+ AUX3+ RESERVED AIN1+ AIN2+ AUX1+ AUX2+ PWR- AUX3- AIN1- AIN2- AUX1- AUX2- M1-CMN M2-CMN 485-A 485-B 485-CMN PARALLEL AUTOMATION SYSTEM / SYSTEM HOOKUP FOR ONE (1) ELSTER-AMCO EtherMeter -Industrial Interface PRODUCT/MAC ID LABEL EM-100 EtherMeter PATENTED MAC ID: 00-1D-C8-nn-nn-nn FLASH PROGRAMMING HEADER LCD DISPLAY PWR TxD AIN1: AIN2: RxD XMT JP1 JP2 S ETUP 120 OHM RS-232 ON DCD LCD ADJ RUN RS-485 NO OFF CONTROL ELSTER-AMCO 4
6 PWR+ AUX3+ RESERVED AIN1+ AIN2+ AUX1+ AUX2+ PWR- AUX3- AIN1- AIN2- AUX1- AUX2- M1-CMN M2-CMN 485-A 485-B 485-CMN PARALLEL AUTOMATION SYSTEM / SYSTEM HOOKUP FOR TWO (2) SENSUS-COMPATIBLE S EtherMeter -Industrial Interface PRODUCT/MAC ID LABEL EM-100 EtherMeter PATENTED MAC ID: 00-1D-C8-nn-nn-nn FLASH PROGRAMMING HEADER LCD DISPLAY PWR TxD AIN1: JP1 AIN2: JP2 S ETUP RS OHM ON RxD XMT DCD LCD ADJ RUN RS-485 NO OFF CONTROL SENSUS-COMPATIBLE SENSUS-COMPATIBLE 5
7 PWR+ AUX3+ RESERVED AIN1+ AIN2+ AUX1+ AUX2+ PWR- AUX3- AIN1- AIN2- AUX1- AUX2- M1-CMN M2-CMN 485-A 485-B 485-CMN PARALLEL AUTOMATION SYSTEM / SYSTEM HOOKUP FOR TWO (2) NEPTUNE S EtherMeter -Industrial Interface PRODUCT/MAC ID LABEL EM-100 EtherMeter PATENTED MAC ID: 00-1D-C8-nn-nn-nn FLASH PROGRAMMING HEADER LCD DISPLAY PWR TxD AIN1: JP1 AIN2: JP2 S ETUP RS OHM ON RxD XMT DCD LCD ADJ RUN RS-485 NO OFF CONTROL NEPTUNE NEPTUNE 6
8 PWR+ AUX3+ RESERVED AIN1+ AIN2+ AUX1+ AUX2+ PWR- AUX3- AIN1- AIN2- AUX1- AUX2- M1-CMN M2-CMN 485-A 485-B 485-CMN PARALLEL AUTOMATION SYSTEM / SYSTEM HOOKUP FOR TWO (2) ELSTER-AMCO S EtherMeter -Industrial Interface PRODUCT/MAC ID LABEL EM-100 EtherMeter PATENTED MAC ID: 00-1D-C8-nn-nn-nn FLASH PROGRAMMING HEADER LCD DISPLAY PWR TxD AIN1: JP1 AIN2: JP2 S ETUP RS OHM ON RxD XMT DCD LCD ADJ RUN RS-485 NO OFF CONTROL ELSTER-AMCO ELSTER-AMCO 7
9 PARALLEL TOUCH-PAD HOOKUPS TOUCH-READ PAD MODEL# RRF-50 SENSUS-COMPATIBLE TOUCHPAD HOOKUP SENSUS-COMPATIBLE TOUCH-READ PAD NEPTUNE TOUCHPAD HOOKUP NEPTUNE 8
10 TOUCH-READ PAD ELSTER-AMCO TOUCHPAD HOOKUP ELSTER-AMCO 9
11 PARALLEL VISULINK DISPLAY UNIT HOOKUP VL9 VisuLink Meter Display Unit By Kemp-Meek Manufacturing Company SENSUS-COMPATIBLE SENSUS-COMPATIBLE / VISULINK HOOKUP 10
12 VL9 VisuLink Meter Display Unit By Kemp-Meek Manufacturing Company NEPTUNE NEPTUNE / VISULINK HOOKUP 11
13 VL9 VisuLink Meter Display Unit By Kemp-Meek Manufacturing Company ELSTER-AMCO ELSTER-AMCO / VISULINK HOOKUP 12
14 DIMENSIONAL DRAWINGS DIN-RAIL-MOUNT VERSION Inches Inches Inches 13
15 DEEP (4x) B B COVER REVISION DATE SUGGESTED PC BOARD LAYOUT SECTION B-B (4x) C.177 (2x) 4.5 PART NAME PART No. NEMA 4X PLASTIC BOX w/external MTG. BRKT. PN-1323-MB PN-1323-CMB PN-1323-DGMB MATERIAL & FINISH: (-MB SUFFIX PART NO.) POLYCARBONATE UL94-HB, UV STABILIZED, SERVICE TEMPERATURE RANGE: -40 C TO +120 C, GRAY BODY & COVER. (-CMB SUFFIX PART NO.) SAME AS -MB EXCEPT CLEAR COVER. (-DGMB SUFFIX PART NO.) ABS UL94-HB, SERVICE TEMPERATURE RANGE: -40 C TO +80 C, DARK GRAY BODY & COVER..177 (4x) A x DETAIL C SILICONE SPONGE GASKET.177 TYP (4x) A M4x0.7 x.315 LG. SECTION A-A 8 THREADED BRASS INSERT (4x).309 BOSS WITH.098 HOLE x.158 DEEP (4x) 4 MOUNTING BOSSES ACCEPT M3 x 4mm LG. OR #4 x 3/16" LG. SELF-TAPPING SCREWS (NOT SUPPLIED) BODY.181 TYP (2x) MOUNTING HOLES ACCEPT M4 OR #8 PAN HEAD SCREW (NOT SUPPLIED) NOTES: 1.) FOUR (4) M4x0.7 x 20mm (.787") LG. STAINLESS STEEL SCREWS SUPPLIED FOR ASSEMBLY OF COVER TO BODY. 2.) BOXES DESIGNED TO MEET FOLLOWING STANDARDS: NEMA 1, 2, 4, 4X, 12, 13 AND IEC529-IP65 REQUIREMENTS. 3.) ALL HOLE DIAS HAVE.005[.12] TOLERANCE. ALL OTHER DIMENSIONS HAVE.015[.38] TOLERANCE. 4.) ALL OUTSIDE DRAFT ANGLE: 1 ALL INSIDE DRAFT ANGLE: 1/ R TYP.
Radio-Read Filter ALLOWS TWO METER-READING DEVICES TO CONCURRENTLY CONNECT TO A WATER METER
adio-ead Filter ALLOWS TWO METE-EADIN DEVICES TO CONCUENTLY CONNECT TO A WATE METE 2 YEA WAANTY DIN-AIL-MOUNT VESION WALL-MOUNT VESION Wiring Diagrams 04 Oct 2013 1 See the Compatibility Matrix at for
More informationEtherMeter FLOW METER GATEWAY FOR SCADA, TELEMETRY, & BUILDING AUTOMATION SYSTEMS COVERED BY US PATENT NO. 8,219,214
EtherMeter FLOW METER GATEWAY FOR SCADA, TELEMETRY, & BUILDING AUTOMATION SYSTEMS COVERED BY US PATENT NO. 8,219,214 Installation, Operation, and Maintenance Manual Version 2.08 12 November 2017 AUTHORIZED
More informationPolycarbonate Watertight 03 Product Drawings Last Updated 4/2/2007
PHOENIX MECNO COMPNY Polycarbonate Watertight 03 Product Drawings Last Updated 4/2/2007 Rose+Bopla Enclosures 7330 Executive Way Frederick, MD 21704 www.rose-bopla.com customerservice@rose-bopla.com For
More informationEtherMeter SCADA / METER GATEWAY PATENT PENDING
EtherMeter SCADA / METER GATEWAY PATENT PENDING Installation, Operation, and Maintenance Manual Version 1.04 28 November 2009 AUTHORIZED SCADAMETRICS RESELLER SCADAmetrics St. Louis, Missouri USA scadametrics.com
More informationABS Watertight 09 Product Drawings Last Updated 1/6/2006
PHOENIX MECNO COMPNY BS Watertight 09 Product Drawings Last Updated 1/6/2006 Rose+Bopla Enclosures 7330 Executive Way Frederick, MD 21704 301-696-9800 www.rose-bopla.com customerservice@rose-bopla.com
More informationEtherMeter FLOW METER GATEWAY FOR SCADA, TELEMETRY, & BUILDING AUTOMATION SYSTEMS COVERED BY US PATENT NO. 8,219,214
EtherMeter FLOW METER GATEWAY FOR SCADA, TELEMETRY, & BUILDING AUTOMATION SYSTEMS COVERED BY US PATENT NO. 8,219,214 Installation, Operation, and Maintenance Manual Version 2.06 10 Oct 2012 AUTHORIZED
More informationWP SERIES IP67 UV-PROTECT PLASTIC ENCLOSURE. What's IP67? ASA Plastic has the great weather resistance. High waterproof performance by silicone gasket
IP7 UV-PROTECT PLASTIC ENCLOSURE What's IP7? IP Code is an "Ingress Protection Marking" under IEC 529 and rates the degree of protection provided against the intrusion, dust, and water. IPx : Completely
More informationEtherMeter FLOW METER GATEWAY FOR SCADA, TELEMETRY, & BUILDING AUTOMATION SYSTEMS COVERED BY US PATENT NO. 8,219,214
EtherMeter FLOW METER GATEWAY FOR SCADA, TELEMETRY, & BUILDING AUTOMATION SYSTEMS COVERED BY US PATENT NO. 8,219,214 Flow-Meter Compatibility Matrix 11 March 2015 AUTHORIZED SCADAMETRICS RESELLER SCADAmetrics
More informationEtherMeter SCADA / METER GATEWAY PATENT PENDING
EtherMeter SCADA / METER GATEWAY PATENT PENDING Installation, Operation, and Maintenance Manual Version 1.02 28 October 2009 AUTHORIZED SCADAMETRICS RESELLER SCADAmetrics St. Louis, Missouri USA scadametrics.com
More informationOperation and Maintenance Manual
VM Series Operation and Maintenance Manual VM - Voltage Monitor VM-100-24 V VM-100-48 V VM-100-125 V VM-100-250 V EAGLE EYE POWER SOLUTIONS All Rights Reserved. 1 The Voltage Monitor series reads battery
More informationIn-Sight I/O. In-Sight expansion module (For use with in-sight 5000 series vision sensors and Id readers, and 3400 vision sensors)
System DISTRIBUTEUR C ONSEIL DEPUIS 1 9 8 5 In-Sight i/o specifications In-Sight BREakout module (For use with in-sight 5000 series vision sensors and id readers) Note: All measurements are provided in
More informationSystem D I S T R I B U T E U R C O N S E I L D E P U I S vision sensors PRODUCT SPECIFICATIONS AND DRAWINGS
System D I S T R I B U T E U R C O N S E I L D E P U I S 1 9 8 5 vision sensors PRODUCT SPECIFICATIONS AND DRAWINGS 2006-1 specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 Memory
More informationCONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual
5915 SDI-12 Interface Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:
More informationHardened 4-Port 10/100/1000M DIN-Rail Mount Switch GATB. User's Manual (V1.0 Version)
Hardened 4-Port 10/100/1000M DIN-Rail Mount Switch 065-7404GATB User's Manual (V1.0 Version) 1 Overview The Signamax 065-7404GATB industrial Ethernet switches are entry-level industrial 4-port Ethernet
More informationIndustrial Unmanaged Ethernet Switch
Industrial Unmanaged Ethernet Switch IES-1050A / 1080A Series User s Manual Version 1.0 May, 2008. ORing Industrial Networking Corp. 4F., NO.3, Lane235, Baociao Rd.Sindian City, Taipei County 23145 Taiwan,
More information52 x 50 x light-grey, similar to RAL 7035 CM /1 CM 52/DT /1 CT /1 CT 52/DT /1 M A/B C/D PG A/B C/D
Polycarbonate/ABS housings Protection class: IP66 acc. to EN 60529 Protective insulation: complete protective insulation Burning behaviour PC: UL 94-V2 Burning behaviour ABS: UL 94-HB Toxicity: halogen-free
More informationIndustrial Slim Type Fast Ethernet Rail Switch
Industrial Slim Type Fast Ethernet Rail Switch Version 1.0 May, 2008. Table of Content Overview...2 1.1 About the 505710 / 505628 unmanaged Industrial Switch...2 1.2 Hardware Features...2 Hardware Installation...3
More informationPolycarbonate and ABS QLINE E
Spec-00410 D763.422.2211 763.422.2600 Polycarbonate and ABS QLINE E Polycarbonate and ABS QLINE E QLINE E, Type 4X INDUSTRY STANDARDS Polycarbonate Enclosure UL 8A Listed; Type 4, 4X, 6, 12, 13; File No.
More informationEE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210
Humidity and Temperature Transmitter for Demanding Climate Control The transmitter by E+E Elektronik meets the highest requirements in demanding climate control applications. Besides the accurate measurement
More informationPolycarbonate and ABS QLINE E
763.422.2600 Spec-00410 E763.422.2211 Polycarbonate and ABS QLINE E Polycarbonate and ABS QLINE E QLINE E, Type 4X INDUSTRY STANDARDS Polycarbonate Enclosure UL 8A Listed; Type 4, 4X, 6, 12, 13; File No.
More informationFeatures and Benefits. SNMP MIB-II for network management. Certifications
NPort 5600-DT Series 8-port RS-232/422/485 serial device servers Features and Benefits 8 serial ports supporting RS-232/422/485 Compact desktop design 10/100M auto-sensing Ethernet Easy IP address configuration
More informationEmergency Luminaire for Fluorescent Lamps Series EXLUX 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationINJ-24A Series Quick Installation Guide
INJ-24A Series Quick Installation Guide Moxa High-Power PoE+ Injector Edition 4.1, August 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More information1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications
UPort 1000 Series 1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters Features and Benefits Hi-Speed USB 2.0 for up to 480 Mbps USB data transmission rates 921.6 kbps maximum baudrate
More informationPolycarbonate and ABS QLINE D
Spec-008 F76..11 76..0 Polycarbonate and abs QLINE D QLINE D, Type X INDUSTRY StandardS Polycarbonate Enclosure UL 508A Listed; Type, X, 6, 1, 1; File No. E619 cul Listed per CSA C. No 9; Type, X, 6, 1,
More informationImmersion Temperature Sensors
1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or
More informationMiniature Inductive Prox TL-W
Miniature Inductive Prox Subminiature, Flat-Pack DC Sensor Fits Tight Spaces Watertight construction conforms to IP67 Space-saving mounting area, as small as 10 x 27 mm ( 0.39 x 1.06 in), is ideal for
More informationPhotoelectric Sensors E3F2
Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel
More informationVL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features
A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.
More informationproduct specifications d
RadioRA 2 Repeaters extend the range of Radio Frequency () signals that are sent between dimmers, switches, keypads, visor controls, shades / draperies, and other devices. Repeaters ensure error-free communication
More informationCatalog C-035 Rev. C
Catalog C-035 Rev. C P O S I T R O N I C I N D U S T R I E S Today, some customer applications have requirements for high bandwidth transfer between VMEbus cards. Requirements which even the most updated
More informationArm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications
IA260 Series Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA Features and Benefits Cirrus Logic EP9315 Arm9 CPU, 200 MHz 128 MB RAM onboard, 32 MB flash disk
More informationVirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual
VirtualSCADA USB to RS422/485 Isolated Converter User Manual Revision 1.01.00 Page 1 (15) Table of contents Warranty and support... 3 Product return... 3 1 About the VirtualSCADA USB to RS422/485 Converter...
More informationMODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders R1M Series PC RECORDER (contact output, 32 points) Functions & Features Industrial recorder on PC 32-point open collector outputs Easy system expansion via Modbus RTU Recorded data exportable
More informationZone Pressure Touch Sensor - Standard Range
Overview The Zone Pressure Touch (ZPT) Sensor is an accurate, rugged and economical solution for measuring and reporting duct/ building static pressure, room-to-room differential pressure or air velocities/volumes.
More informationIndustrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and
Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and 2x100/1000Base-X, SFP socket, 24VDC power input Features provide 4x10/100/1000Base-T(X) PoE (P.S.E.) ports
More informationSuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998
SuperBus Hardwire Input Module (HIM) Document Number: 466-1033 Rev. C September 1998 SuperBus Hardwire Input Module for installing a magnetic reed switch* that can provide tamper protection when the switch
More informationCombiView DFON Graphical display
Main features with backlight Showing errors and limits by steady or flashing colours Fits Baumer CombiSeries TM (Ø80 mm FlexHousing) Hygienic design Option: Two configurable relay outputs Programmable
More informationBOARD LEVEL POWER SEMICONDUCTOR HEAT SINKS
217 SERIES Surface Mount D 2 PAK,, SOT-223, SOL-2 Compatible with surface mount technology (SMT) automated production techniques for ease of assembly and a variety of soldering methods, these heat sinks
More informationenglish Cable Entry Systems EMC Solutions innovative creative technology Product program A company of the icotek group
english 26 Cable Entry Systems EMC Solutions innovative creative technology Product program A company of the icotek group Customer requests and our constant involvement in ever changing markets is motivation
More informationZone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions
Product Identification BAPI s Touch Low Range Pressure Sensor with Attached Static Pressure Probe is an accurate, rugged and economical solution for measuring and reporting duct/building static pressure,
More informationPolycarbonate and ABS QLINE D
Spec-008 QLINE D, Type X INDUSTRY STANDARDS Polycarbonate Enclosure UL 508A Listed; Type, X, 6, 1, 1; File No. E619 cul Listed per CSA C. No 9; Type, X, 6, 1, 1; File No. E619 Enclosure flammability evaluated
More informationVL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features
Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL
More informationDX3309 / DP1009 / DD / DC1009 Series
DX3309 / DP1009 / DD100980 / DC1009 Series FFv Proximity Probe Assembly MNX10071 REV C 11/6/2017 1 CONTENTS Section 1 : Overview... 4 Introduction... 4 Description... 4 Section 2: Probe Details... 5 Proximity
More informationiopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission
iopac 8020 Series Rugged modular RTU controllers Compliant with EN 50121-3-2, EN 50121-4, and a portion of EN 50155 specifications Supports C/C++ programming languages 2-port Ethernet switch for daisy-chain
More informationI-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US
I-7560U/7561U/7563U User Manual USB tto RS--232//422//485 Converrtterrss Verr.. 1..0,, Decc.. 2013 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of
More informationEE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211
Humidity and Temperature Transmitter for Continuous High Humidity The is dedicated for accurate and long term stable measurement under continuous high humidity (>85 % RH) and condensing conditions in demanding
More informationEtherMeter FLOW METER GATEWAY FOR SCADA, TELEMETRY, & BUILDING AUTOMATION SYSTEMS COVERED BY US PATENT NO. 8,219,214
EtherMeter FLOW METER GATEWAY FOR SCADA, TELEMETRY, & BUILDING AUTOMATION SYSTEMS COVERED BY US PATENT NO. 8,219,214 Flow-Meter Compatibility Matrix 24 October 2018 AUTHORIZED SCADAMETRICS RESELLER SCADAmetrics
More informationHMT330 Series Humidity and Temperature Transmitters for Industrial Applications
HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. Six models for demanding industrial
More informationMODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to
More informationD12 Series DIN Rail High Power Fiber Optic Sensor
Datasheet Powerful Self-Contained Sensors for Use with Glass or Plastic Fiber Optic Assemblies Fiber optic sensors for DIN rail mounting; cabled or quick disconnect (QD) Fast response: 500 μs standard,
More informationGeneral Specifications
General Specifications Yokogawa Y-Flow Remote Terminal Unit (YRTU) Overview Yokogawa s low power YRTU offers flexible I/O points and superior data collection with a wide range of connectivity options.
More informationIndustrial 8-port unmanaged Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E., 24VDC power inputs
Industrial 8-port unmanaged Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E., 24VDC power inputs Features provide 8x10/100/1000Base-T(X) PoE (P.S.E.) ports Supports IEEE 802.3at compliant
More informationInsertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )
The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed
More informationFeatures and Benefits. Certifications
TCF-142 Series RS-232/422/485 to fiber converters Features and Benefits Ring and point-to-point transmission Extends RS-232/422/485 transmission up to 40 km with single-mode (TCF- 142-S) or 5 km with multi-mode
More informationiopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission
iopac 8020 Series Rugged modular RTU controllers Compliant with EN 50121-3-2, EN 50121-4, and a portion of EN 50155 specifications Supports C/C++ programming languages 2-port Ethernet switch for daisy-chain
More informationZone Pressure Touch (ZPT) Sensor - Standard Range
Product Identification BAPI s Touch Pressure Sensor is an accurate, rugged and economical solution for measuring and reporting duct/ building static pressure, room-to-room differential pressure or air
More informationaccurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service
Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow
More informationTAPR GPS Kit USER S GUIDE
TAPR GPS Kit USER S GUIDE GPS Kit parts derived from the original Synergy Systems, LLC SynPaQ/E M12+ version Shipped as-is without Warranty These GPS Kit parts were previously used in a timing application
More informationEE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310
High-End Humidity and Temperature Transmitter for Demanding Process Control is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative
More information10/100Base-TX Industrial Ethernet Extender
Quick Start Guide This quick start guide describes how to install and use the Ethernet Extender. The Ethernet Extender introduced here provides one channel for Ethernet over existing coaxial cable. Product
More informationThe INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided
Industrial 2-port Gigabit High Power PoE Injector, 24V~50V Input Support Features Supports 2x10/100/1000Base-T(X) for power and data Output Fully compliant with IEEE802.3at/802.3af standard Auto protection
More informationOnCell G3150A-LTE Series
OnCell G3150A-LTE Series Rugged LTE serial/ethernet-to-cellular gateways Features and Benefits Dual cellular operator backup with dual-sim GuaranLink for reliable cellular connectivity Rugged hardware
More informationNPort 5200 Series. 2-port RS-232/422/485 serial device servers. Specifications. Serial-to-Ethernet Device Servers
NPort 5200 Series 2-port RS-232/422/485 serial device servers Compact design for easy installation Socket modes: TCP server/tcp client/udp Easy-to-use Windows utility for configuring multiple device servers
More informationEnergy Scout Basic Watthour Meter Model ESB-
H Energy Scout Basic Watthour Meter Model ESB- EASY INSTALLATION The model ESB is a Watthour meter with integrated current transformers and a form A solid state contact pulse output. The model ESB may
More informationiologik E1200H Series
iologik E1200H Series Ethernet remote I/O for offshore wind power applications Features and Benefits User-definable Modbus TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Active
More informationFILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane
Filter Caps for Humidity and Dewpoint Transmitters with probe 12 mm (0.47 ) The right choice of appropriate filter cap is essential for best long term performance in the application. For assistance please
More informationMODEL: R2K-1 SEN TRONIC AG. R2K Series
1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission
More informationIndustrial Ethernet Switch
Quick Start Guide This quick start guide describes how to install and use the hardened Ethernet Switch. Capable of operating at temperature extremes of -10 C to +60 C, this is the switch of choice for
More informationMGate 4101-MB-PBS Series
MGate 4101-MB-PBS Series 1-port Modbus RTU/ASCII-to-PROFIBUS slave gateways Features and Benefits Protocol conversion between Modbus and PROFIBUS Supports PROFIBUS DP V0 slave Supports Modbus RTU/ASCII
More informationProduct STC-E42A STC-E43A. Chip Size 7.40 (H) x 5.95 (V) mm 5.59 (H) x 4.68 (V) mm Cell Size 8.4 (H) x 9.8 (V) µm 6.35 (H) x 7.
I. Specifications A. Electronic Specifications / Mechanical Specifications / Environmental Conditions Product STC-E42A STC-E43A Electronic Specification Mechanical Specifications Environmental Conditions
More informationContinuous level measurement Ultrasonic controllers
Siemens AG 0 Overview is a complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms. Benefits Monitoring and
More informationLCE SERIES EMC SHIELDED HAND-HELD PLASTIC CASE. Accessories (Optional parts) LCE series is an EMC shielded version of LC hand-held plastic case
LCE SERIES EMC SHIELDED HAND-HELD PLASTIC CASE EMC Shielding Effects 2 4 LCE series is an EMC shielded version of LC hand-held plastic case Technical Data Protection class: IP40 Operating temperature:
More informationIndustrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input
Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input Features Supports 2x10/100/1000Base-T(X) for power and data Fully compliant with IEEE802.3at/802.3af standard Auto protection for Over
More informationEE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe
Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow
More informationUltrasonic Proximity Sensors
Model SM500 Series SUPERPROX Ultrasonic Proximity Sensors No delay sensing Easy pushbutton setup for the specific application Onboard microprocessor for reliability and repeatability Noncontact sensing
More informationPixus Technologies Catalog
The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com US: 96.524.8242 CAN: 59.885.5775 Product Diversity
More informationL-MBUS20/L-MBUS80. User Manual. M-Bus Level Converter. LOYTEC electronics GmbH
L-MBUS20/L-MBUS80 M-Bus Level Converter User Manual Contact LOYTEC Blumengasse 35 A-1170 Vienna AUSTRIA/EUROPE support@loytec.com http://www.loytec.com Document 88077901 LOYTEC MAKES AND YOU RECEIVE NO
More informationSeries SD-3PB Digital THERMOSTAT + TIMER
SD-3PB Thermostat and Interval Timer in one Unit. This microcomputer based controller consists of two sections: The Digital Timer and Digital Thermostat, working together to control the power switched
More informationAluform Watertight Enclosures Product Drawings Last Updated 9/29/2008
ROSE+BOPL PHOENIX MECNO COMPNY luform Watertight Enclosures Product Drawings Last Updated 9/29/2008 Rose+Bopla Enclosures 7330 Executive Way Frederick, MD 21704 www.rose-bopla.com rbinfo@pm-usa.com Dimensional
More information-C5RS-LC RS232 EXTENDER
XTENDEX Series ST-C5RS-LC RS232 EXTENDER Installation and Operation Manual ST-C5RS-LC RS232 Extender Man249 Rev. 10/30/17 TRADEMARK XTENDEX is a registered trademark of Network Technologies Inc in the
More informationChecker is the sensor. CheckMate is the software that runs on your PC. You use CheckMate to set up Checker mm mm 4.
Quick Reference About Checker Checker is the sensor. CheckMate is the software that runs on your PC. You use CheckMate to set up Checker. Minimum PC Requirements Microsoft Windows 2000 or Windows XP 400MHz
More informationArm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications
UC-7100 Series Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports Features and Benefits MOXA ART Arm9 32-bit 192 MHz processor 16 or 32 MB RAM 8 or 16 MB Flash ROM Dual or single
More informationIAP-320 series are reliable a/b/g WLAN Access Point with 2 ports LAN. It supports 802.1X and MAC filters for
IAP-320 / IAP-320+ Industrial IEEE 802.11 a/b/g wireless access point with 2x10/100Base-T(X) Features High Speed Air Connectivity: WLAN interface support up to 54Mbps link speed Highly Security Capability:
More informationI/O Expansion Module Installation & Reference
Overview The In-Sight vision sensor supports up to ten discrete inputs and ten discrete outputs. Two inputs and two outputs are built-in to the In-Sight processor. The remaining eight inputs and outputs
More informationEX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)
EX-1331-4KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) 1. Introduction Thank you for purchasing this RS232/422/485 3-in-1 Serial to USB Adapter. It is an
More informationPowerView Model PV1000. Hardware Installation Manual Section 78
PowerView Model PV1000 Hardware Installation Manual 00-02-0599 07-19-07 Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications
More informationFeatures. Parts Supplied. Parts not Supplied. Tools Required. ADC780 Series Indoor/Outdoor Vandal-Resistant Cameras. Installation and Setup Guide
ADC780 Series Indoor/Outdoor Vandal-Resistant Cameras Installation and Setup Guide Features Adjustable camera mount Indoor/Outdoor installation (except flush mount) ¾- and ½-inch conduit holes 24Vac hookup
More informationUser Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX
User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX Entry Line Fast Ethernet Switch Fast Ethernet Switch for Industrial Use Page 2/11 Table of Contents General... 3 Benefits... 3 Front
More informationMLS7A Series. Photoelectric Sensors. Heavy-Duty Retro-Reflective Sensors. Photoelectric MLS7A Series Heavy Duty PEPPERL+FUCHS 529
Retro-Reflective Mode See page 53 Sensing Ranges: 3m Outputs: NPN MLS7A Series Heavy-Duty Retro-Reflective Sensors Heavy Duty Cast aluminium housing Side mount or flange mount Photoelectric MLS7A Series
More informationMULTICHANNEL DATA RECORDERS
MULTICHANNEL DATA RECORDERS Introduction ma + V / mv RTD + - universal inputs + - TC universal inputs: RTD + TC or U + I (SRD-99) fixed inputs: RTD, TC, U, I (SRD-N16) 2 relay outputs memory up to 3 000
More informationPS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters
PS-AULDP Series Datasheet Ultra Low Air Differential Pressure Transmitters Overview The PS-AULDP Series are ultra-low-pressure transmitters. These devices can be used to measure differential pressure between
More informationiologik 4000 Series (M) Modules
iologik 4000 Series (M) s Remote I/O modules Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin
More informationTouchPAD TPD/VPD Series HMI Device User Manual
TouchPAD TPD/VPD Series HMI Device User Manual Version 1.1.0, Jul. 2015 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of
More informationANT Vandal Resistant 3G/4G/LTE Omni-Directional Antenna
Applications Kiosks Vending Machines Digital Signage Video Surveillance Point-of-Sale Terminals SCADA / Telemetry / PLCs Product Features Vandal Resistant Low Profile ~ 3 inches Tall Weatherproof Compatible
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More informationSingle action door patch fittings
Single action door patch fittings The flexible system for all installation situations. CONTENTS Technical details - 5 Materials and surface finishes Product information Patch fittings / none rebated frame
More informationFrom ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets
1147 Detector SERIES Related Information General terms and conditions... F-7 General precautions...p.151 PHOTO PHOTO MEASURE ITY From ultra-thin lead frames to iron sheets... Double feed detection of various
More informationenglish Cable Entry Systems EMC Solutions innovative creative technology Product catalogue A company of the icotek group
english 27 Cable Entry Systems EMC Solutions innovative creative technology Product catalogue A company of the icotek group Ideas move Ideas move the world icotek GmbH is a privately held company in the
More informationEE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310
is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative humidity (RH) and temperature (T), the transmitter also calculates parameters
More information