Temporal coverage :00: :59:59 NAME RECORD FIELD TH VALUE STATUS ACTION

Size: px
Start display at page:

Download "Temporal coverage :00: :59:59 NAME RECORD FIELD TH VALUE STATUS ACTION"

Transcription

1 GOME-2 Metop-A NRT Quality Monitoring of the GOME-2 FM3 Instrument and Level 1A,B products Daily report Start orbit End orbit Issue date :02:00 Temporal coverage :00: :59:59 NAME RECORD FIELD TH VALUE STATUS ACTION CAT1 Mode summary Nadir scans SPHR N_NADIR_SCAN nominal - North pole scans SPHR N_NTH_POLE_SCAN - 0 nominal - South pole scans SPHR N_STH_POLE_SCAN - 0 nominal - Other scans SPHR N_OTHER_SCAN - 0 nominal - Static nadir scans SPHR N_NADIR_STATIC - 0 nominal - Other static scans SPHR N_OTHER_STATIC - 0 nominal - Dark MDRs SPHR N_DARK nominal - LED MDRs SPHR N_LED - 0 nominal - WLS MDRs SPHR N_WLS - 33 nominal - SLS MDRs SPHR N_SLS - 0 nominal - SLS/Diffuser MDRs SPHR N_SLS_DIFF - 0 nominal - Sun MDRs SPHR N_SUN - 33 nominal - Moon MDRs SPHR N_MOON - 0 nominal - Idle MDRs SPHR N_IDLE - 0 nominal - Test MDRs SPHR N_TEST - 0 nominal - Dump MDRs SPHR N_DUMP - 0 nominal - Invalid MDRs SPHR N_INVALID nominal - CAT2 Product critical monitoring results Missing scans SPHR N_MISSING_SCANS 1 0 nominal - Mean intensity below threshold SPHR N_MIN_INTENSITY 2 0 nominal - Obs.mode - geolocation mismatch SPHR N_MODE_GEOLOCATION 1 0 nominal - Invalid UTC time SPHR N_INV_UTC 1 0 nominal - Non-nominal detector temperature SPHR N_NN_DETECTOR_TEMP 1 0 nominal - CAT3 Quality critical monitoring results Total scans SPHR N_SCANS nominal - Valid with missing datapackets SPHR N_VALID_WITH_MISS_DP 1 0 nominal - Total missing datapackets SPHR N_MISS_DP 1 0 nominal - Saturated SPHR N_SATURATED 2 10 non-nominal M Hot SPHR N_HOT nominal - Non-nominal PDP temperature SPHR N_NN_PDP_TEMP 1 0 nominal - Non-nominal radiator temperature SPHR N_NN_RAD_TEMP 1 0 nominal - Non-nominal WLS voltage SPHR N_NN_WLS_U 3 1 nominal - Non-nominal WLS current SPHR N_NN_WLS_I 3 1 nominal - Non-nominal SLS voltage SPHR N_NN_SLS_U 2 0 nominal - Non-nominal SLS current SPHR N_NN_SLS_I 2 0 nominal - CAT4 Product quality critical monitoring results Old calibration data MDR_1A/B PCD_BASIC.F_OLD_CAL_DATA 1 0 nominal - Missing Stokes fractions SPHR N_MISS_STOKES nominal - Bad Stokes fractions SPHR N_BAD_STOKES nominal - Dark mean above threshold VIADR-1a-Dark PCD_DARK.F_AV_DARK 1 0 nominal - Dark noise above threshold VIADR-1a-Dark PCD_DARK.F_AV_DARK_NOISE 5 0 nominal - Missing dark VIADR-1a-Dark PCD_DARK.F_AV_DARK_MISS 5 0 nominal - Backup PPG algorithm VIADR-1a_PPG PCD_PPG_BACK 1 0 nominal - Mean PPG exceeds threshold VIADR-1a-PPG PCD_PPG.F_AV_PPG 1 0 nominal - PPG stddev exceed threshold VIADR-1a-PPG PCD_PPG.F_STDDEV_PPG 1 0 nominal - Missing LED VIADR-1a-PPG PCD_PPG.PCD_F_PPG_MISS 1 0 nominal - SLS missing VIADR-1a_PPG PCD_F_SPEC_MISS 1 0 nominal - Not enough spectral lines VIADR-1a-SPEC PCD_SPEC_N_LINES 1 0 nominal - SLS low voltage SPA-1a-Hk SLS_U_MAX 1 0 nominal - Line deviation above treshold VIADR-1a-SPEC PCD_SPEC_MAX_LINE_DEV 1 0 nominal - PMD speccal not converged VIADR-1a-SPEC PCD_SPEC_F_NO_CONVERGEN nominal - PMD speccal low goodness-of-fit VIADR-1a-SPEC PCD_SPEC_F_GOF 1 0 nominal - Backup Etalon algorithm VIADR-1a_ETAL.. ETALON_BACK 1 0 nominal - Eta_res above treshold VIADR_1a_ETA.. PCD_F_AV_ETALON 1 0 nominal - Eta_res. dev. above treshold VIADR_1a_ETA.. PCD_F_STDDEV_ETALON 1 0 nominal - Eta_cppg above treshold VIADR_1a_ETA.. PCD_F_AV_RESIDUAL 1 0 nominal - Eta_sigma_cppg above treshold VIADR_1a_ETA.. PCD_F_STDDEV_RESIDUAL 1 0 nominal - Missing Etalon VIADR_1a_ETA.. PCD_ETALON.F_ETALON_MISS 1 0 nominal - Missing SUN VIADR-SMR PCM_SMR_MISS 1 0 nominal - Too few scans for SMR VIADR-SMR PCD_SMR.F_N_INTENSITY 1 0 nominal - [AD1] EPS Programme - Near real time monitoring and quality control of GOME 2 L1 and onboard processing; EPS.OPS.DOC [AD2] EPS Programme Status Report GOME2 - Product Processing from PPF version 3; EPS.OPS.DOC S: Solution required immediately E: Evalute (no immediate action needed, evaluation required) M: Monitor incidence (no immediate action needed, wait for other occurrences) Page 1 of 18

2 Product quality :00: :59:59 Ozone line ratio :00: :59:59 Page 2 of 18

3 False colour image :00: :59:59 NDVI proxy :00: :59:59 Page 3 of 18

4 Near-Infrared :00: :59:59 Product quality indicator :31: :27: Average overall quality: 98.8 % Quality [%] :00 02:00 04:00 06:00 08:00 10:00 12:00 14:00 16:00 18:00 20:00 22:00 00:00 Time Overall quality (CAT 2-4) Dark correction quality PPG correction quality Etalon correction quality SpecCal quality SMR quality Page 4 of 18

5 Reflectance (Sahara) :00: :59: Reflectance (subset 0)[ ] Reflectance (Pacific) :00: :59: Reflectance (subset 1)[ ] Page 5 of 18

6 Reflectance (Greenland) :00: :59: Reflectance (subset 2)[ ] Earth Stokes fractions :00: :59: Earth Stokes fractions for special geometries[ ] Page 6 of 18

7 Sun Stokes fractions :00: :59: Sun Stokes fractions[ ] Dark correction FPA :00: :59:59 Mean [BU] Band 1A mean temp: K Band 1B mean temp: K Band 2A mean temp: K Band 2B mean temp: K Band 3 mean temp: K Band 4 mean temp: K Band 1A integration time: 1.5 s Band 1B integration time: s Band 2A integration time: s Band 2B integration time: s Band 3 integration time: s Band 4 integration time: s Mean noise [BU] ,000 1,250 1,500 1,750 2,000 2,250 2,500 2,750 3,000 3,250 3,500 3,750 4, detector pixel [-] Dark correction[ ] Mean noise[ ] Page 7 of 18

8 Dark signal PMD (raw) :00: :59:59 1,500 1,400 1,300 1,200 Band PMD-P mean temp: 0 K Band PMD-S mean temp: 0 K IT = s TM = calibration RM = raw , Mean [BU] 1, Mean noise [BU] detector pixel [-] PMD-P[ ] PMD-S[ ] PMD-P Mean noise[ ] PMD-S Mean noise[ ] Dark signal PMD (band) :00: :59:59 1,500 1,400 1,300 1,200 1,100 Band PMD-P mean temp: K Band PMD-S mean temp: K IT = s TM = nominal RM = band/mixed , Mean [BU] Mean noise [BU] detector pixel [-] PMD-P[ ] PMD-S[ ] PMD-S Mean noise[ ] PMD-P Mean noise[ ] Page 8 of 18

9 LED Mean (FPA) - - No data loaded LED Mean (PMD) - - No data loaded Page 9 of 18

10 PPG FPA - - No data loaded PPG PMD - - No data loaded Page 10 of 18

11 WLS mean (FPA) :00: :59:59 8,000 7,500 7, ,500 6, Mean [BU/s] 5,500 5,000 4,500 4,000 3,500 3, Standard deviation [BU/s] 2, ,000 1, , ,000 1,250 1,500 1,750 2,000 2,250 2,500 2,750 3,000 3,250 3,500 3,750 4,000 detector pixel 0.0 Mean[ ] Standard deviation[ ] WLS Mean (PMD) :00: :59: , , , Mean [BU/s] 40,000 35,000 30,000 25,000 20, Standard deviation [BU/s] 15, , , detector pixel 0 Mean PMD-P[ ] Mean PMD-S[ ] Standard deviation PMD-P[ ] Standard deviation PMD-S[ ] Page 11 of 18

12 Etalon correction FPA :20: :23: Etalon[ ] Etalon correction PMD :20: :23: PMD-P[ ] PMD-S[ ] Page 12 of 18

13 SLS mean / stddev - - No data loaded SLS Mean (PMD) - - No data loaded Page 13 of 18

14 Lambda shift wrt. keydata (FPA) - - No data loaded Lambda shift wrt. key data (PMD) - - No data loaded Page 14 of 18

15 Fitted shifts (Fraunhofer) :47: :48: (!) Spectral shift [nm] (!) channel 1 channel 2 channel 3 channel 4 SMR FPA :47: :48: E E E E E E E14 photons/(s.cm^2.nm) E E E E E E E E E E E E E SMR (latest available)[ ] Page 15 of 18

16 SMR PMD :47: :48: E E E E14 photons/(s.cm^2.nm) E E E E E E E PMD-P (latest available)[ ] PMD-S (latest available)[ ] Scan motor torque statistics :00: :00: Nm Time Page 16 of 18

17 Torque profile - - Scan mirror pos statistics :00: :00: degree Time Page 17 of 18

18 Scan mirror position :00: :00:00 degree :00: No data loaded Time [ ] Scan mirror pos diff to ref Input data gaps :00: :59:59 MON1B Input MON1A Input L1B Input L1A Input L0 input MDR 1B MDR 1A 01:00 03:00 05:00 07:00 09:00 11:00 13:00 15:00 17:00 19:00 21:00 23:00 Page 18 of 18

Temporal coverage :00: :59:59 NAME RECORD FIELD TH VALUE STATUS ACTION

Temporal coverage :00: :59:59 NAME RECORD FIELD TH VALUE STATUS ACTION GOME-2 Metop-A NRT Quality Monitoring of the GOME-2 FM3 Instrument and Level 1A,B products Daily report Start orbit End orbit 60895 60910 Issue date 2018-07-16 04:02:09 Temporal coverage 2018-07-15 00:00:00

More information

GOME-2 Factsheet. Doc.No. : EUM/OPS/DOC/10/1299 Issue : v4d e-signed Date : 27 April 2017 WBS/DBS : EUMETSAT

GOME-2 Factsheet. Doc.No. : EUM/OPS/DOC/10/1299 Issue : v4d e-signed Date : 27 April 2017 WBS/DBS : EUMETSAT Doc.No. : EUM/OPS/DOC/10/1299 Issue : v4d e-signed Date : 27 April 2017 WBS/DBS : EUMETSAT Eumetsat-Allee 1, D-64295 Darmstadt, Germany Tel: +49 6151 807-7 Fax: +49 6151 807 555 http://www.eumetsat.int

More information

IASI on MetOp-B Radiometric Calibration

IASI on MetOp-B Radiometric Calibration IASI on MetOp-B Radiometric Calibration V. Lonjou 1, E. Péquignot 1, L. Buffet 1, J. Chinaud 1, S. Gaugain 1, E. Jacquette 1, D. Jouglet 1, C. Larigauderie 1, C. Villaret 1, J. Donnadille 2, B. Tournier

More information

The IASI Instrument. on the assimilation of IASI in NWP Reading, May 6-8, ECMWF / NWP-SAF Workshop ! "# $ !" #$%& #$!$$

The IASI Instrument. on the assimilation of IASI in NWP Reading, May 6-8, ECMWF / NWP-SAF Workshop ! # $ ! #$%& #$!$$ The IASI Instrument ECMWF / NWP-SAF Workshop on the assimilation of IASI in NWP Reading, May 6-8, 2009! "# $!" #$%& #$!$$ '($$)$$ Outline 1. Introduction 2. Functional Behaviour & Availability 3. Radiometric

More information

Product Specification Document of the GOME Data Processor

Product Specification Document of the GOME Data Processor Deutsches Zentrum für Luft und Raumfahrt e.v. of the GOME Processor July 31, 2002 Deutsches Zentrum für Luft und Raumfahrt e.v. DLR Institut für Methodik der Fernerkundung IMF Oberpfaffenhofen, Germany

More information

Meteosat Third Generation (MTG) Lightning Imager (LI) instrument performance and calibration from user perspective

Meteosat Third Generation (MTG) Lightning Imager (LI) instrument performance and calibration from user perspective Meteosat Third Generation (MTG) Lightning Imager (LI) instrument performance and calibration from user perspective Marcel Dobber, Jochen Grandell EUMETSAT (Darmstadt, Germany) 1 Meteosat Third Generation

More information

TES Algorithm Status. Helen Worden

TES Algorithm Status. Helen Worden TES Algorithm Status Helen Worden helen.m.worden@jpl.nasa.gov Outline TES Instrument System Testing Algorithm updates One Day Test (ODT) 2 TES System Testing TV3-TV19: Interferometer-only thermal vacuum

More information

CRISM (Compact Reconnaissance Imaging Spectrometer for Mars) on MRO. Calibration Upgrade, version 2 to 3

CRISM (Compact Reconnaissance Imaging Spectrometer for Mars) on MRO. Calibration Upgrade, version 2 to 3 CRISM (Compact Reconnaissance Imaging Spectrometer for Mars) on MRO Calibration Upgrade, version 2 to 3 Dave Humm Applied Physics Laboratory, Laurel, MD 20723 18 March 2012 1 Calibration Overview 2 Simplified

More information

SAC-D/Aquarius. HSC - Radiometric Calibration H Raimondo M Marenchino. An Observatory for Ocean, Climate and Environment

SAC-D/Aquarius. HSC - Radiometric Calibration H Raimondo M Marenchino. An Observatory for Ocean, Climate and Environment An Observatory for Ocean, Climate and Environment SAC-D/Aquarius HSC - Radiometric Calibration H Raimondo M Marenchino 1 Buenos Aires April 11-13, 2012 HSC - Switchable ranges Ø HSC is a versatile instrument.

More information

Suomi NPP CrIS Reprocessed SDR Long-term Accuracy and Stability

Suomi NPP CrIS Reprocessed SDR Long-term Accuracy and Stability Suomi NPP CrIS Reprocessed SDR Long-term Accuracy and Stability Yong Chen 1, Yong Han, Likun Wang 1, Fuzhong Weng, Ninghai Sun, and Wanchun Chen 1 CICS-MD, ESSIC, University of Maryland, College Park,

More information

CrIS SDR Calibration and Cross-sensor Comparisons

CrIS SDR Calibration and Cross-sensor Comparisons CrIS SDR Calibration and Cross-sensor Comparisons Yong Han NOAA Center for Satellite Applications and Research, College Park, MD, USA and CrIS SDR Science Team ITSC-19 March 25 April 1, 2014 Jeju Island,

More information

OTO Photonics. Sidewinder TM Series Datasheet. Description

OTO Photonics. Sidewinder TM Series Datasheet. Description OTO Photonics Sidewinder TM Series Datasheet Description SW (Sidewinder TM ) Series spectrometer,built with the InGaAs type sensor and high performance 32bits RISC controller in, is specially designed

More information

Ice Cover and Sea and Lake Ice Concentration with GOES-R ABI

Ice Cover and Sea and Lake Ice Concentration with GOES-R ABI GOES-R AWG Cryosphere Team Ice Cover and Sea and Lake Ice Concentration with GOES-R ABI Presented by Yinghui Liu 1 Team Members: Yinghui Liu 1, Jeffrey R Key 2, and Xuanji Wang 1 1 UW-Madison CIMSS 2 NOAA/NESDIS/STAR

More information

GEOG 4110/5100 Advanced Remote Sensing Lecture 2

GEOG 4110/5100 Advanced Remote Sensing Lecture 2 GEOG 4110/5100 Advanced Remote Sensing Lecture 2 Data Quality Radiometric Distortion Radiometric Error Correction Relevant reading: Richards, sections 2.1 2.8; 2.10.1 2.10.3 Data Quality/Resolution Spatial

More information

Revision History. Applicable Documents

Revision History. Applicable Documents Revision History Version Date Revision History Remarks 1.0 2011.11-1.1 2013.1 Update of the processing algorithm of CAI Level 3 NDVI, which yields the NDVI product Ver. 01.00. The major updates of this

More information

MERIS US Workshop. Vicarious Calibration Methods and Results. Steven Delwart

MERIS US Workshop. Vicarious Calibration Methods and Results. Steven Delwart MERIS US Workshop Vicarious Calibration Methods and Results Steven Delwart Presentation Overview Recent results 1. CNES methods Deserts, Sun Glint, Rayleigh Scattering 2. Inter-sensor Uyuni 3. MOBY-AAOT

More information

Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD (301) (301) fax

Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD (301) (301) fax Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD 20723 (301) 953-6871 (301) 953-6670 fax Understand the instrument. Be able to convert measured counts/pixel on-orbit into

More information

Assessments of MODIS On-orbit Spatial and Spectral Characterization

Assessments of MODIS On-orbit Spatial and Spectral Characterization EOS Assessments of MODIS On-orbit Spatial and Spectral Characterization Jack Xiong, Dan Link, Kevin Twedt, and Ben Wang NASA GSFC, Greenbelt, MD 0, USA SSAI, 00 Greenbelt Road, Lanham, MD 00, USA Acknowledgements

More information

Reprocessing of Suomi NPP CrIS SDR and Impacts on Radiometric and Spectral Long-term Accuracy and Stability

Reprocessing of Suomi NPP CrIS SDR and Impacts on Radiometric and Spectral Long-term Accuracy and Stability Reprocessing of Suomi NPP CrIS SDR and Impacts on Radiometric and Spectral Long-term Accuracy and Stability Yong Chen *1, Likun Wang 1, Denis Tremblay 2, and Changyong Cao 3 1.* University of Maryland,

More information

MHS Instrument Pre-Launch Characteristics

MHS Instrument Pre-Launch Characteristics MHS Instrument Pre-Launch Characteristics Jörg Ackermann, EUMETSAT, October 2017 The main objective of satellite instruments pre-launch characterisation is to ensure that the observed instrument performance

More information

Product Specification Document of the GOME Data Processor

Product Specification Document of the GOME Data Processor Deutsches Zentrum für Luft und Raumfahrt e.v. of the GOME Processor December 15, 2004 Deutsches Zentrum für Luft und Raumfahrt e.v. DLR Institut für Methodik der Fernerkundung IMF Oberpfaffenhofen, Germany

More information

Beginner s Guide to VIIRS Imagery Data. Curtis Seaman CIRA/Colorado State University 10/29/2013

Beginner s Guide to VIIRS Imagery Data. Curtis Seaman CIRA/Colorado State University 10/29/2013 Beginner s Guide to VIIRS Imagery Data Curtis Seaman CIRA/Colorado State University 10/29/2013 1 VIIRS Intro VIIRS: Visible Infrared Imaging Radiometer Suite 5 High resolution Imagery channels (I-bands)

More information

7.1 Advanced Himawari Imager (AHI) Design and Operational Flexibility Dr. Paul C. Griffith

7.1 Advanced Himawari Imager (AHI) Design and Operational Flexibility Dr. Paul C. Griffith 7.1 Advanced Himawari Imager (AHI) Design and Operational Flexibility Dr. Paul C. Griffith 12th Annual Symposium on New Generation Operational Environmental Satellite Systems This document is not export

More information

Utilization of AGI STK and S-NPP Operational Data to Generate JPSS-1 Proxy Test Data

Utilization of AGI STK and S-NPP Operational Data to Generate JPSS-1 Proxy Test Data Utilization of AGI STK and S-NPP Operational Data to Generate JPSS-1 Proxy Test Data Emily Greene Wael Ibrahim Chris van Poollen Ed Meletyan Scott Leszczynski 2018 AMS Annual Meeting Austin, TX, USA Copyright

More information

Modeling of the ageing effects on Meteosat First Generation Visible Band

Modeling of the ageing effects on Meteosat First Generation Visible Band on on Meteosat First Generation Visible Band Ilse Decoster, N. Clerbaux, J. Cornelis, P.-J. Baeck, E. Baudrez, S. Dewitte, A. Ipe, S. Nevens, K. J. Priestley, A. Velazquez Royal Meteorological Institute

More information

Polar Multi-Sensor Aerosol Product: User Guide

Polar Multi-Sensor Aerosol Product: User Guide Polar Multi-Sensor Aerosol Product: User Guide Doc.No. : EUM/TSS/MAN/14/742654 Issue : V2 e-signed Date : 8 January 2016 WBS : EUMETSAT Eumetsat-Allee 1, D-64295 Darmstadt, Germany Tel: +49 6151 807-7

More information

SPICAM Archive Tutorial. Principal Investigator : J.L. Bertaux Archive Manager : A. Reberac

SPICAM Archive Tutorial. Principal Investigator : J.L. Bertaux Archive Manager : A. Reberac SPICAM Archive Tutorial Principal Investigator : J.L. Bertaux Archive Manager : A. Reberac 1 SPICAM Archive Tutorial SPICAM Instrument SPICAM data levels/products SPICAM Archive volume set organization

More information

Summary of Publicly Released CIPS Data Versions.

Summary of Publicly Released CIPS Data Versions. Summary of Publicly Released CIPS Data Versions. Last Updated 13 May 2012 V3.11 - Baseline data version, available before July 2008 All CIPS V3.X data versions followed the data processing flow and data

More information

Description of NOMAD Observation Types and HDF5 Datasets NOT YET COMPLETE

Description of NOMAD Observation Types and HDF5 Datasets NOT YET COMPLETE NOMAD Science Team KONINKLIJK BELGISCH INSTITUUT VOOR RUIMTE-AERONOMIE INSTITUT ROYAL D AERONOMIE SPATIALE DE BELGIQUE ROYAL BELGIAN INSTITUTE OF SPACE AERONOMY KONINKLIJK BELGISCH INSTITUUT VOOR RUIMTE-AERONOMIE

More information

Challenges in data compression for current and future imagers and hyperspectral sounders

Challenges in data compression for current and future imagers and hyperspectral sounders Challenges in data compression for current and future imagers and hyperspectral sounders Nigel Atkinson (Met Office) ITSC-19, Jeju, 28 March 2014 or How to store your satellite data without needing too

More information

S2 MPC Data Quality Report Ref. S2-PDGS-MPC-DQR

S2 MPC Data Quality Report Ref. S2-PDGS-MPC-DQR S2 MPC Data Quality Report Ref. S2-PDGS-MPC-DQR 2/13 Authors Table Name Company Responsibility Date Signature Written by S. Clerc & MPC Team ACRI/Argans Technical Manager 2015-11-30 Verified by O. Devignot

More information

How GOSAT has provided uniform-quality spectra and optimized global sampling patterns for seven years

How GOSAT has provided uniform-quality spectra and optimized global sampling patterns for seven years IWGGMS -12 Session II: SWIR Spectroscopy & Retrieval Algorithms How GOSAT has provided uniform-quality spectra and optimized global sampling patterns for seven years June 7, 2016, Kyoto Akihiko KUZE, Kei

More information

Supplementary materials of Multispectral imaging using a single bucket detector

Supplementary materials of Multispectral imaging using a single bucket detector Supplementary materials of Multispectral imaging using a single bucket detector Liheng Bian 1, Jinli Suo 1,, Guohai Situ 2, Ziwei Li 1, Jingtao Fan 1, Feng Chen 1 and Qionghai Dai 1 1 Department of Automation,

More information

GOCI Post-launch calibration and GOCI-II Pre-launch calibration plan

GOCI Post-launch calibration and GOCI-II Pre-launch calibration plan Breakout Session: Satellite Calibration, IOCS Meeting 2015, 18 June 2015. GOCI Post-launch calibration and GOCI-II Pre-launch calibration plan Seongick CHO Korea Ocean Satellite Center, Korea Institute

More information

SDG1400 User s Guide

SDG1400 User s Guide SDG1400 User s Guide Model SDG1400 Rate Sensor Systron Donner Inertial Sales and Customer Service Phone: +1 925.979. 4500 Fax: +1 925.349.1366 E-Mail: sales@systron.com www.systron.com SDG1400 User s Guide

More information

VIIRS Radiance Cluster Analysis under CrIS Field of Views

VIIRS Radiance Cluster Analysis under CrIS Field of Views VIIRS Radiance Cluster Analysis under CrIS Field of Views Likun Wang, Yong Chen, Denis Tremblay, Yong Han ESSIC/Univ. of Maryland, College Park, MD; wlikun@umd.edu Acknowledgment CrIS SDR Team 2016 CICS

More information

ASTER User s Guide. ERSDAC Earth Remote Sensing Data Analysis Center. 3D Ortho Product (L3A01) Part III. (Ver.1.1) July, 2004

ASTER User s Guide. ERSDAC Earth Remote Sensing Data Analysis Center. 3D Ortho Product (L3A01) Part III. (Ver.1.1) July, 2004 ASTER User s Guide Part III 3D Ortho Product (L3A01) (Ver.1.1) July, 2004 ERSDAC Earth Remote Sensing Data Analysis Center ASTER User s Guide Part III 3D Ortho Product (L3A01) (Ver.1.1) TABLE OF CONTENTS

More information

Results of Cross-comparisons using multiple sites

Results of Cross-comparisons using multiple sites Results of Cross-comparisons using multiple sites Dave Smith CEOS WGCV IVOS workshop 18-20 Oct 2010 1 Content AATSR Drift Analysis AATSR vs. MERIS comparisons over Deserts Intercomparisons Over Dome-C

More information

Evaluation of Satellite Ocean Color Data Using SIMBADA Radiometers

Evaluation of Satellite Ocean Color Data Using SIMBADA Radiometers Evaluation of Satellite Ocean Color Data Using SIMBADA Radiometers Robert Frouin Scripps Institution of Oceanography, la Jolla, California OCR-VC Workshop, 21 October 2010, Ispra, Italy The SIMBADA Project

More information

430g Dimensions. 102mm x 84mm x 59mm Detector nm Pixels 3648 Pixel size. 8μm x 200μm Pixel well depth

430g Dimensions. 102mm x 84mm x 59mm Detector nm Pixels 3648 Pixel size. 8μm x 200μm Pixel well depth Weigth 430g Dimensions 102mm x 84mm x 59mm Detector Toshiba TCD1304DG linear array Detector range 200-1200nm Pixels 3648 Pixel size 8μm x 200μm Pixel well depth 100,000 electrons Signal-to-noise ratio

More information

False Color to NDVI Conversion Precision NDVI Single Sensor

False Color to NDVI Conversion Precision NDVI Single Sensor False Color to NDVI Conversion Precision NDVI Single Sensor Contents 1 Sensor Properties... 2 2 Isolating Bands... 2 3 Calculating NDVI from Original Image Pixel DN... 3 4 Calculating NDVI from AgVault

More information

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold L-LAS Series L-LAS-LT-85-RA-CL (Reduced Amplification) - Operates in an angle of total reflection - Suitable für high-glossy objects (e.g. glass) - Line laser

More information

SCIAMACHY. Level 0 to 1b Processing. Input / Output Data Definition

SCIAMACHY. Level 0 to 1b Processing. Input / Output Data Definition SCIAMACHY Level 0 to 1b Processing Input / Output Data Definition 14. July 2009 Deutsches Zentrum für Luft- und Raumfahrt e.v. - DLR Deutsches Fernerkundungsdatenzentrum - DFD Oberpfaffenhofen Germany

More information

Interactive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al.

Interactive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al. Atmos. Meas. Tech. Discuss., www.atmos-meas-tech-discuss.net/5/c741/2012/ Author(s) 2012. This work is distributed under the Creative Commons Attribute 3.0 License. Atmospheric Measurement Techniques Discussions

More information

Interactive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al.

Interactive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al. Atmos. Meas. Tech. Discuss., 5, C741 C750, 2012 www.atmos-meas-tech-discuss.net/5/c741/2012/ Author(s) 2012. This work is distributed under the Creative Commons Attribute 3.0 License. Atmospheric Measurement

More information

MERIS Instrument Status

MERIS Instrument Status MERIS Instrument Status presented by Stefan Weiß Photo: Courtesy Alcatel Space Industries Page 1 MERIS Instrument Status Functional Description & Hardware overview Functional check-out & Operations Telemetry

More information

Simulation and Analysis of an Earth Observation Mission Based on Agile Platform

Simulation and Analysis of an Earth Observation Mission Based on Agile Platform Simulation and Analysis of an Earth Observation Mission Based on Agile Platform Augusto Caramagno Fabrizio Pirondini Dr. Luis F. Peñín Advanced Projects Division DEIMOS Space S.L. -1 - Engineering activities

More information

MonoVista CRS+ Raman Microscopes

MonoVista CRS+ Raman Microscopes MonoVista CRS+ Benefits Deep UV to NIR wavelength range Up to 4 integrated multi-line lasers plus port for large external lasers Dual beam path for UV and VIS/NIR Motorized Laser selection Auto Alignment

More information

Onboard Blackbody Calibration Algorithm of Chinese FY-2 Geostationary Imager Based on GSICS Reference Radiances

Onboard Blackbody Calibration Algorithm of Chinese FY-2 Geostationary Imager Based on GSICS Reference Radiances Onboard Blackbody Calibration Algorithm of Chinese FY-2 Geostationary Imager Based on GSICS Reference Radiances Xiuqing (Scott) Hu 1,4, Likun Wang 2, Fuzhong Weng 3, and Na Xu 4 1. ERT@NOAA/NESDIS/STAR,

More information

OtO Photonics. Sidewinder TM Series Datasheet. Description

OtO Photonics. Sidewinder TM Series Datasheet. Description OtO Photonics Sidewinder TM Series Datasheet Description SW (Sidewinder TM ) Series spectrometer,built with the InGaAs type sensor and high performance 32bits RISC controller in, is specially designed

More information

Calibration Techniques for NASA s Remote Sensing Ocean Color Sensors

Calibration Techniques for NASA s Remote Sensing Ocean Color Sensors Calibration Techniques for NASA s Remote Sensing Ocean Color Sensors Gerhard Meister, Gene Eplee, Bryan Franz, Sean Bailey, Chuck McClain NASA Code 614.2 Ocean Biology Processing Group October 21st, 2010

More information

Snow cover change detection with laser scanning range and brightness measurements

Snow cover change detection with laser scanning range and brightness measurements Snow cover change detection with laser scanning range and brightness measurements Sanna Kaasalainen, Harri Kaartinen, Antero Kukko, Henri Niittymäki Department of Remote Sensing and Photogrammetry 5th

More information

SCIAMACHY Command Line Tool Software User's Manual (SUM)

SCIAMACHY Command Line Tool Software User's Manual (SUM) SCIAMACHY Command Line Tool Software User's Manual (SUM) SCIAMACHY Level 1b to 1c processing SciaL1c Page 2 of 71 Distribution List Name Affiliation Copies A. Dehn ESA-ESRIN 1 T. Fehr ESA-ESRIN 1 B. Aberle

More information

ENHANCEMENT OF DIFFUSERS BRDF ACCURACY

ENHANCEMENT OF DIFFUSERS BRDF ACCURACY ENHANCEMENT OF DIFFUSERS BRDF ACCURACY Grégory Bazalgette Courrèges-Lacoste (1), Hedser van Brug (1) and Gerard Otter (1) (1) TNO Science and Industry, Opto-Mechanical Instrumentation Space, P.O.Box 155,

More information

Ralf K. Heilmann CAT-GS: Critical-Angle Transmission Grating Spectrometer January 27,

Ralf K. Heilmann CAT-GS: Critical-Angle Transmission Grating Spectrometer January 27, Ralf K. Heilmann CAT-GS: Critical-Angle Transmission Grating Spectrometer January 27, 2009 1 Overview of CAT-GS Mission requirements: Effective area > 1000 cm 2 (0.3 1 kev) Spectral resolution E/ΔE > 3000

More information

Modern Surveying Techniques. Prof. S. K. Ghosh. Department of Civil Engineering. Indian Institute of Technology, Roorkee.

Modern Surveying Techniques. Prof. S. K. Ghosh. Department of Civil Engineering. Indian Institute of Technology, Roorkee. Modern Surveying Techniques Prof. S. K. Ghosh Department of Civil Engineering Indian Institute of Technology, Roorkee Lecture - 12 Rectification & Restoration In my previous session, I had discussed regarding

More information

Polar Multi-Sensor Aerosol Product: ATBD

Polar Multi-Sensor Aerosol Product: ATBD Polar Multi-Sensor Aerosol Product: ATBD Doc.No. : EUM/TSS/SPE/14/739904 Issue : v3b e-signed Date : 30 November 2015 WBS : EUMETSAT Eumetsat-Allee 1, D-64295 Darmstadt, Germany Tel: +49 6151 807-7 Fax:

More information

SWAP Image Calibration. Daniel B. Seaton, D. Shaun Bloomfield, ROB & TCD SWAP Teams

SWAP Image Calibration. Daniel B. Seaton, D. Shaun Bloomfield, ROB & TCD SWAP Teams SWAP Image Calibration Daniel B. Seaton, D. Shaun Bloomfield, ROB & TCD SWAP Teams Primary Image Calibration Steps Implemented Dark Subtraction Pixel Map Correction Image Scaling, Rotation, & Centering

More information

SPIcam: an overview. Alan Diercks Institute for Systems Biology 23rd July 2002

SPIcam: an overview. Alan Diercks Institute for Systems Biology 23rd July 2002 SPIcam: an overview Alan Diercks Institute for Systems Biology diercks@systemsbiology.org 23rd July 2002 1 Outline Overview of instrument CCDs mechanics instrument control performance construction anecdotes

More information

Frequently Asked Questions: excelon Back Illuminated CCD/EMCCD Cameras

Frequently Asked Questions: excelon Back Illuminated CCD/EMCCD Cameras Frequently Asked Questions: excelon Back Illuminated CCD/EMCCD Cameras 1. What is excelon? excelon is a new CCD/EMCCD sensor technology jointly developed by Princeton Instruments, e2v and Photometrics.

More information

Sentinel-3 OLCI: Status

Sentinel-3 OLCI: Status Sentinel-3 OLCI: Status Jens Nieke, F. Borde, C. Mavrocordatos OLCI Status 26 Nov 2013 ESRIN 1 Outline Background OLCI development status Assembly, Testing & Integration (AIT) Camera EM and FM test results

More information

IASI spectral calibration monitoring on MetOp-A and MetOp-B

IASI spectral calibration monitoring on MetOp-A and MetOp-B IASI spectral calibration monitoring on MetOp-A and MetOp-B E. Jacquette (1), B. Tournier (2), E. Péquignot (1), J. Donnadille (2), D. Jouglet (1), V. Lonjou (1), J. Chinaud (1), C. Baque (3), L. Buffet

More information

Kaguya s HDTV and Its Imaging

Kaguya s HDTV and Its Imaging Kaguya s HDTV and Its Imaging C h a p t e r 2 Overview of the HDTV System In addition to Kaguya s 13 science instruments, the HDTV was unique in being specifically included to engage the public in the

More information

Raman Spectrometer Installation Manual

Raman Spectrometer Installation Manual RI Raman Spectrometer Instruction Manual Application software (included in standard configuration) Connection RI RAMAN is recognized by Windows operational system as standard HID device. That is why there

More information

MTG-FCI: ATBD for Clear Sky Reflectance Map Product

MTG-FCI: ATBD for Clear Sky Reflectance Map Product MTG-FCI: ATBD for Clear Sky Reflectance Map Product Doc.No. Issue : : v2 EUMETSAT Eumetsat-Allee 1, D-64295 Darmstadt, Germany Tel: +49 6151 807-7 Fax: +49 6151 807 555 Date : 14 January 2013 http://www.eumetsat.int

More information

ENMAP RADIOMETRIC INFLIGHT CALIBRATION

ENMAP RADIOMETRIC INFLIGHT CALIBRATION ENMAP RADIOMETRIC INFLIGHT CALIBRATION Harald Krawczyk 1, Birgit Gerasch 1, Thomas Walzel 1, Tobias Storch 1, Rupert Müller 1, Bernhard Sang 2, Christian Chlebek 3 1 Earth Observation Center (EOC), German

More information

Prototyping GOES-R Albedo Algorithm Based on MODIS Data Tao He a, Shunlin Liang a, Dongdong Wang a

Prototyping GOES-R Albedo Algorithm Based on MODIS Data Tao He a, Shunlin Liang a, Dongdong Wang a Prototyping GOES-R Albedo Algorithm Based on MODIS Data Tao He a, Shunlin Liang a, Dongdong Wang a a. Department of Geography, University of Maryland, College Park, USA Hongyi Wu b b. University of Electronic

More information

SPECTRAL IMAGING VIEWER SOFTWARE MANUAL

SPECTRAL IMAGING VIEWER SOFTWARE MANUAL 103 Quality Circle, Suite 215 Huntsville, AL 35806 Phone: (256) 704-3332 Fax: (256) 971-2073 E-Mail: info@axometrics.com Website: http://www.axometrics.com SPECTRAL IMAGING VIEWER SOFTWARE MANUAL 2012

More information

FC Series Traffic Camera. Architect & Engineering Specifications

FC Series Traffic Camera. Architect & Engineering Specifications FC Series Traffic Camera Architect & Engineering Specifications This document is controlled to FLIR Technology Level 1. The information contained in this document pertains to a dual use product controlled

More information

NIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

NIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection Powered by LightField The NIRvana: 64ST from Princeton Instruments is the world s first scientific grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy

More information

Minimizes reflection losses from UV - IR; Optional AR coatings & wedge windows are available.

Minimizes reflection losses from UV - IR; Optional AR coatings & wedge windows are available. Now Powered by LightField PyLoN:100 1340 x 100 The PyLoN :100 is a controllerless, cryogenically-cooled CCD camera designed for quantitative scientific spectroscopy applications demanding the highest possible

More information

SCIAMACHY Command Line Tool SciaL1c Software User s Manual

SCIAMACHY Command Line Tool SciaL1c Software User s Manual SCIAMACHY Command Line Tool SciaL1c Software User s Manual Issue 2/B Page 2 of 62 Distribution Name Affiliation Copies Name Affiliation Copies Thorsten Fehr ESA/ESRIN 1 Bernd Aberle DLR 1 Rob Koopman ESA/ESRIN

More information

Manual Software R-LAS-LT-Scope (LT-Scope) V1.1

Manual Software R-LAS-LT-Scope (LT-Scope) V1.1 Manual Software R-LAS-LT-Scope (LT-Scope) V1.1 (PC software for Microsoft Windows 7, 8, 10) for Laser Reflection Sensor R-LAS-LT-110-HD2 This manual describes the installation process of the software for

More information

See more with the NEW testo 880 thermal imager

See more with the NEW testo 880 thermal imager Committing to the future See more with the NEW testo 880 thermal imager NEW! SEE MORE......OFFER MORE. Infrared radiation cannot be seen by the human eye. All objects whose temperature is above absolute

More information

EPS Product Validation Report: IASI L1 PCC PPF

EPS Product Validation Report: IASI L1 PCC PPF EPS Product Validation Report: IASI L1 PCC PPF Doc.No. : Issue : v2 Date : 5 August 2010 EUMETSAT Eumetsat-Allee 1, D-64295 Darmstadt, Germany Tel: +49 6151 807-7 Fax: +49 6151 807 555 http://www.eumetsat.int

More information

Working with M 3 Data. Jeff Nettles M 3 Data Tutorial at AGU December 13, 2010

Working with M 3 Data. Jeff Nettles M 3 Data Tutorial at AGU December 13, 2010 Working with M 3 Data Jeff Nettles M 3 Data Tutorial at AGU December 13, 2010 For Reference Slides and example data from today s workshop available at http://m3dataquest.jpl.nasa.gov See Green et al. (2010)

More information

Radiance, Irradiance and Reflectance

Radiance, Irradiance and Reflectance CEE 6100 Remote Sensing Fundamentals 1 Radiance, Irradiance and Reflectance When making field optical measurements we are generally interested in reflectance, a relative measurement. At a minimum, measurements

More information

Sentinel-1 Toolbox. TOPS Interferometry Tutorial Issued May 2014

Sentinel-1 Toolbox. TOPS Interferometry Tutorial Issued May 2014 Sentinel-1 Toolbox TOPS Interferometry Tutorial Issued May 2014 Copyright 2015 Array Systems Computing Inc. http://www.array.ca/ https://sentinel.esa.int/web/sentinel/toolboxes Interferometry Tutorial

More information

Geometric Rectification of Remote Sensing Images

Geometric Rectification of Remote Sensing Images Geometric Rectification of Remote Sensing Images Airborne TerrestriaL Applications Sensor (ATLAS) Nine flight paths were recorded over the city of Providence. 1 True color ATLAS image (bands 4, 2, 1 in

More information

MODIS Atmosphere: MOD35_L2: Format & Content

MODIS Atmosphere: MOD35_L2: Format & Content Page 1 of 9 File Format Basics MOD35_L2 product files are stored in Hierarchical Data Format (HDF). HDF is a multi-object file format for sharing scientific data in multi-platform distributed environments.

More information

SYNCERITY TM 1024 x 256

SYNCERITY TM 1024 x 256 ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING SYNCERITY TM 1024 x 256 Open-Electrode TE-Cooled CCD

More information

S-NPP CrIS Full Resolution Sensor Data Record Processing and Evaluations

S-NPP CrIS Full Resolution Sensor Data Record Processing and Evaluations S-NPP CrIS Full Resolution Sensor Data Record Processing and Evaluations Yong Chen 1* Yong Han 2, Likun Wang 1, Denis Tremblay 3, Xin Jin 4, and Fuzhong Weng 2 1 ESSIC, University of Maryland, College

More information

Thermal Imaging Solutions

Thermal Imaging Solutions 2016 PRODUCT CATALOGUE Thermal Imaging Solutions www.tanzsecurity.com FL SERIES FL-A Series Focus : Motorized lens Pan : NA Tilt : NA Presets : NA Weight : 2 Kg. Size : 130x96x305mm. FL-B Series Focus

More information

Software requirements * : Part III: 2 hrs.

Software requirements * : Part III: 2 hrs. Title: Product Type: Developer: Target audience: Format: Software requirements * : Data: Estimated time to complete: Mapping snow cover using MODIS Part I: The MODIS Instrument Part II: Normalized Difference

More information

Light Tec Scattering measurements guideline

Light Tec Scattering measurements guideline Light Tec Scattering measurements guideline 1 Our Laboratory Light Tec is equipped with a Photometric Laboratory (a dark room) including: Goniophotometers: REFLET180s. High specular bench (10 meters),

More information

SL 200 instrument can process the energy intensity emitted by the solar radiation in a precise place of the earth.

SL 200 instrument can process the energy intensity emitted by the solar radiation in a precise place of the earth. Solarimeter SL 200 Table of contents 1 Introduction...4 2 General information...4 2.1 Measured units...4 2.2 Use...4 3 Operating principle...5 3.1 Keyboard presentation...5 3.2 Instrument offers 3 groups

More information

Creating Situational Awareness with Spacecraft Data Trending and Monitoring

Creating Situational Awareness with Spacecraft Data Trending and Monitoring Creating Situational Awareness with Spacecraft Data Trending and Monitoring Zhenping Li ASRC Technical Services, Zhenping.Li@asrcfederal.com J.P. Douglas, and Ken Mitchell ASRC Technical Services, JPaul.Douglas@noaa.gov

More information

Easy integration into complex experimental setup

Easy integration into complex experimental setup NIRvana: 64ST The NIRvana: 64ST from Princeton Instruments is the world s first scientific grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy applications.

More information

Machine learning approach to retrieving physical variables from remotely sensed data

Machine learning approach to retrieving physical variables from remotely sensed data Machine learning approach to retrieving physical variables from remotely sensed data Fazlul Shahriar November 11, 2016 Introduction There is a growing wealth of remote sensing data from hundreds of space-based

More information

Sentinel-2 Calibration and Validation : from the Instrument to Level 2 Products

Sentinel-2 Calibration and Validation : from the Instrument to Level 2 Products Sentinel-2 Calibration and Validation : from the Instrument to Level 2 Products Vincent Lonjou a, Thierry Tremas a, Sophie Lachérade a, Cécile Dechoz a, Florie Languille a, Aimé Meygret a, Olivier Hagolle

More information

Improvements to Ozone Mapping Profiler Suite (OMPS) Sensor Data Record (SDR)

Improvements to Ozone Mapping Profiler Suite (OMPS) Sensor Data Record (SDR) Improvements to Ozone Mapping Profiler Suite (OMPS) Sensor Data Record (SDR) *C. Pan 1, F. Weng 2, T. Beck 2 and S. Ding 3 * 1 ESSIC, University of Maryland, College Park, MD 20740; 2 NOAA NESDIS/STAR,

More information

VIIRS-CrIS Mapping. P. Brunel, P. Roquet. Météo-France, Lannion. CSPP/IMAPP USERS GROUP MEETING 2015 EUMETSAT Darmstadt, Germany

VIIRS-CrIS Mapping. P. Brunel, P. Roquet. Météo-France, Lannion. CSPP/IMAPP USERS GROUP MEETING 2015 EUMETSAT Darmstadt, Germany VIIRS-CrIS Mapping P. Brunel, P. Roquet Météo-France, Lannion CSPP/IMAPP USERS GROUP MEETING 2015 EUMETSAT Darmstadt, Germany Introduction Mapping? Why? Mapping sounder and imager is of high interest at

More information

Spectral and Radiometric Design of a 3- line CCD Camera for Mars Observation

Spectral and Radiometric Design of a 3- line CCD Camera for Mars Observation Spectral and Radiometric Design of a 3- line CCD Camera for Mars Observation Spectral Design Requirements: spectral range bandwidth spectral characteristics Design: 1. first approach by filter selection

More information

LLA Instruments GmbH. Multiplexed Near-Infrared-Spectrometer KUSTA 4004M. Product description

LLA Instruments GmbH. Multiplexed Near-Infrared-Spectrometer KUSTA 4004M. Product description LLA Instruments GmbH Multiplexed Near-Infrared-Spectrometer KUSTA 4004M Product description General information KUSTA 4004 series The Near- Infrared Spectrometer, in short NIR-Spectrometer, KUSTA 4004

More information

Retrieval of Sea Surface Temperature from TRMM VIRS

Retrieval of Sea Surface Temperature from TRMM VIRS Journal of Oceanography, Vol. 59, pp. 245 to 249, 2003 Short Contribution Retrieval of Sea Surface Temperature from TRMM VIRS LEI GUAN 1,2 *, HIROSHI KAWAMURA 1 and HIROSHI MURAKAMI 3 1 Center for Atmospheric

More information

The Council for Optical Radiation Measurements (CORM), NIST July 30 - Aug 1, 2018

The Council for Optical Radiation Measurements (CORM), NIST July 30 - Aug 1, 2018 Study of the optical properties of black materials at solar reflective wavelengths in support of instrument development and satellite sensor calibration 1Jinan Zeng, 2 Nathan Kelley, 3 James J. Butler,

More information

CORRECTING RS SYSTEM DETECTOR ERROR GEOMETRIC CORRECTION

CORRECTING RS SYSTEM DETECTOR ERROR GEOMETRIC CORRECTION 1 CORRECTING RS SYSTEM DETECTOR ERROR GEOMETRIC CORRECTION Lecture 1 Correcting Remote Sensing 2 System Detector Error Ideally, the radiance recorded by a remote sensing system in various bands is an accurate

More information

Using Python with Smoke and JWST Mirrors. Warren Hack, Perry Greenfield, Babak Saif, Bente Eegholm Space Telescope Science Institute

Using Python with Smoke and JWST Mirrors. Warren Hack, Perry Greenfield, Babak Saif, Bente Eegholm Space Telescope Science Institute Using Python with Smoke and JWST Mirrors Warren Hack, Perry Greenfield, Babak Saif, Bente Eegholm Space Telescope Science Institute The James Webb Space Telescope (JWST) will be the next NASA Great Observatory

More information

IMAGING SPECTROMETER DATA CORRECTION

IMAGING SPECTROMETER DATA CORRECTION S E S 2 0 0 5 Scientific Conference SPACE, ECOLOGY, SAFETY with International Participation 10 13 June 2005, Varna, Bulgaria IMAGING SPECTROMETER DATA CORRECTION Valentin Atanassov, Georgi Jelev, Lubomira

More information

Frequently Asked Questions: Princeton Instruments excelon TM CCD and EMCCD Cameras

Frequently Asked Questions: Princeton Instruments excelon TM CCD and EMCCD Cameras Frequently Asked Questions: Princeton Instruments excelon TM CCD and EMCCD Cameras Updated: Sep 2010 Includes information on excelon TM Back-illuminated Deep Depletion Cameras 1. What is excelon TM? excelon

More information