Temporal coverage :00: :59:59 NAME RECORD FIELD TH VALUE STATUS ACTION
|
|
- Jasper Oliver
- 5 years ago
- Views:
Transcription
1 GOME-2 Metop-A NRT Quality Monitoring of the GOME-2 FM3 Instrument and Level 1A,B products Daily report Start orbit End orbit Issue date :02:09 Temporal coverage :00: :59:59 NAME RECORD FIELD TH VALUE STATUS ACTION CAT1 Mode summary Nadir scans SPHR N_NADIR_SCAN nominal - North pole scans SPHR N_NTH_POLE_SCAN - 0 nominal - South pole scans SPHR N_STH_POLE_SCAN - 0 nominal - Other scans SPHR N_OTHER_SCAN - 0 nominal - Static nadir scans SPHR N_NADIR_STATIC - 0 nominal - Other static scans SPHR N_OTHER_STATIC - 0 nominal - Dark MDRs SPHR N_DARK nominal - LED MDRs SPHR N_LED - 0 nominal - WLS MDRs SPHR N_WLS - 33 nominal - SLS MDRs SPHR N_SLS - 0 nominal - SLS/Diffuser MDRs SPHR N_SLS_DIFF - 0 nominal - Sun MDRs SPHR N_SUN - 33 nominal - Moon MDRs SPHR N_MOON - 0 nominal - Idle MDRs SPHR N_IDLE - 0 nominal - Test MDRs SPHR N_TEST - 0 nominal - Dump MDRs SPHR N_DUMP - 0 nominal - Invalid MDRs SPHR N_INVALID nominal - CAT2 Product critical monitoring results Missing scans SPHR N_MISSING_SCANS 1 0 nominal - Mean intensity below threshold SPHR N_MIN_INTENSITY 2 1 nominal - Obs.mode - geolocation mismatch SPHR N_MODE_GEOLOCATION 1 0 nominal - Invalid UTC time SPHR N_INV_UTC 1 0 nominal - Non-nominal detector temperature SPHR N_NN_DETECTOR_TEMP 1 0 nominal - CAT3 Quality critical monitoring results Total scans SPHR N_SCANS nominal - Valid with missing datapackets SPHR N_VALID_WITH_MISS_DP 1 0 nominal - Total missing datapackets SPHR N_MISS_DP 1 0 nominal - Saturated SPHR N_SATURATED 2 0 nominal - Hot SPHR N_HOT nominal - Non-nominal PDP temperature SPHR N_NN_PDP_TEMP 1 0 nominal - Non-nominal radiator temperature SPHR N_NN_RAD_TEMP 1 0 nominal - Non-nominal WLS voltage SPHR N_NN_WLS_U 3 1 nominal - Non-nominal WLS current SPHR N_NN_WLS_I 3 1 nominal - Non-nominal SLS voltage SPHR N_NN_SLS_U 2 0 nominal - Non-nominal SLS current SPHR N_NN_SLS_I 2 0 nominal - CAT4 Product quality critical monitoring results Old calibration data MDR_1A/B PCD_BASIC.F_OLD_CAL_DATA 1 0 nominal - Missing Stokes fractions SPHR N_MISS_STOKES nominal - Bad Stokes fractions SPHR N_BAD_STOKES nominal - Dark mean above threshold VIADR-1a-Dark PCD_DARK.F_AV_DARK 1 0 nominal - Dark noise above threshold VIADR-1a-Dark PCD_DARK.F_AV_DARK_NOISE 5 1 nominal - Missing dark VIADR-1a-Dark PCD_DARK.F_AV_DARK_MISS 5 0 nominal - Backup PPG algorithm VIADR-1a_PPG PCD_PPG_BACK 1 0 nominal - Mean PPG exceeds threshold VIADR-1a-PPG PCD_PPG.F_AV_PPG 1 0 nominal - PPG stddev exceed threshold VIADR-1a-PPG PCD_PPG.F_STDDEV_PPG 1 0 nominal - Missing LED VIADR-1a-PPG PCD_PPG.PCD_F_PPG_MISS 1 0 nominal - SLS missing VIADR-1a_PPG PCD_F_SPEC_MISS 1 0 nominal - Not enough spectral lines VIADR-1a-SPEC PCD_SPEC_N_LINES 1 0 nominal - SLS low voltage SPA-1a-Hk SLS_U_MAX 1 0 nominal - Line deviation above treshold VIADR-1a-SPEC PCD_SPEC_MAX_LINE_DEV 1 0 nominal - PMD speccal not converged VIADR-1a-SPEC PCD_SPEC_F_NO_CONVERGEN nominal - PMD speccal low goodness-of-fit VIADR-1a-SPEC PCD_SPEC_F_GOF 1 0 nominal - Backup Etalon algorithm VIADR-1a_ETAL.. ETALON_BACK 1 0 nominal - Eta_res above treshold VIADR_1a_ETA.. PCD_F_AV_ETALON 1 0 nominal - Eta_res. dev. above treshold VIADR_1a_ETA.. PCD_F_STDDEV_ETALON 1 0 nominal - Eta_cppg above treshold VIADR_1a_ETA.. PCD_F_AV_RESIDUAL 1 0 nominal - Eta_sigma_cppg above treshold VIADR_1a_ETA.. PCD_F_STDDEV_RESIDUAL 1 0 nominal - Missing Etalon VIADR_1a_ETA.. PCD_ETALON.F_ETALON_MISS 1 0 nominal - Missing SUN VIADR-SMR PCM_SMR_MISS 1 0 nominal - Too few scans for SMR VIADR-SMR PCD_SMR.F_N_INTENSITY 1 0 nominal - [AD1] EPS Programme - Near real time monitoring and quality control of GOME 2 L1 and onboard processing; EPS.OPS.DOC [AD2] EPS Programme Status Report GOME2 - Product Processing from PPF version 3; EPS.OPS.DOC S: Solution required immediately E: Evalute (no immediate action needed, evaluation required) M: Monitor incidence (no immediate action needed, wait for other occurrences) Page 1 of 18
2 Product quality :00: :59:59 Ozone line ratio :00: :59:59 Page 2 of 18
3 False colour image :00: :59:59 NDVI proxy :00: :59:59 Page 3 of 18
4 Near-Infrared :00: :59:59 Product quality indicator :31: :27: Average overall quality: 98.8 % Quality [%] :00 02:00 04:00 06:00 08:00 10:00 12:00 14:00 16:00 18:00 20:00 22:00 00:00 Time Overall quality (CAT 2-4) Dark correction quality PPG correction quality Etalon correction quality SpecCal quality SMR quality Page 4 of 18
5 Reflectance (Sahara) :00: :59: Reflectance (subset 0)[ ] Reflectance (Pacific) :00: :59: Reflectance (subset 1)[ ] Page 5 of 18
6 Reflectance (Greenland) :00: :59: Reflectance (subset 2)[ ] Earth Stokes fractions :00: :59: Earth Stokes fractions for special geometries[ ] Page 6 of 18
7 Sun Stokes fractions :00: :59: Sun Stokes fractions[ ] Dark correction FPA :00: :59:59 Mean [BU] Band 1A mean temp: K Band 1B mean temp: K Band 2A mean temp: K Band 2B mean temp: K Band 3 mean temp: K Band 4 mean temp: K Band 1A integration time: 1.5 s Band 1B integration time: s Band 2A integration time: s Band 2B integration time: s Band 3 integration time: s Band 4 integration time: s Mean noise [BU] ,000 1,250 1,500 1,750 2,000 2,250 2,500 2,750 3,000 3,250 3,500 3,750 4, detector pixel [-] Dark correction[ ] Mean noise[ ] Page 7 of 18
8 Dark signal PMD (raw) :00: :59:59 1,500 1,400 1,300 1,200 1,100 1,000 Band PMD-P mean temp: 0 K Band PMD-S mean temp: 0 K IT = s TM = calibration RM = raw Mean [BU] Mean noise [BU] detector pixel [-] 1.45 PMD-P[ ] PMD-S[ ] PMD-P Mean noise[ ] PMD-S Mean noise[ ] Dark signal PMD (band) :00: :59:59 1,500 1,400 1,300 1,200 1,100 Band PMD-P mean temp: K Band PMD-S mean temp: K IT = s TM = nominal RM = band/mixed , Mean [BU] Mean noise [BU] detector pixel [-] PMD-P[ ] PMD-S[ ] PMD-S Mean noise[ ] PMD-P Mean noise[ ] Page 8 of 18
9 LED Mean (FPA) - - No data loaded LED Mean (PMD) - - No data loaded Page 9 of 18
10 PPG FPA - - No data loaded PPG PMD - - No data loaded Page 10 of 18
11 WLS mean (FPA) :00: :59:59 8,000 7, ,000 6, , ,500 Mean [BU/s] 5,000 4,500 4,000 3,500 3, Standard deviation [BU/s] 2, ,000 1, , ,000 1,250 1,500 1,750 2,000 2,250 2,500 2,750 3,000 3,250 3,500 3,750 4,000 detector pixel 0.0 Mean[ ] Standard deviation[ ] WLS Mean (PMD) :00: :59:59 55,000 50, , Mean [BU/s] 40,000 35,000 30,000 25,000 20, Standard deviation [BU/s] 15, , , detector pixel Mean PMD-P[ ] Mean PMD-S[ ] Standard deviation PMD-P[ ] Standard deviation PMD-S[ ] Page 11 of 18
12 Etalon correction FPA :57: :00: Etalon[ ] Etalon correction PMD :57: :00: PMD-P[ ] PMD-S[ ] Page 12 of 18
13 SLS mean / stddev - - No data loaded SLS Mean (PMD) - - No data loaded Page 13 of 18
14 Lambda shift wrt. keydata (FPA) - - No data loaded Lambda shift wrt. key data (PMD) - - No data loaded Page 14 of 18
15 Fitted shifts (Fraunhofer) :24: :25:26 (!) Spectral shift [nm] (!) channel 1 channel 2 channel 3 channel 4 SMR FPA :24: :25:26 photons/(s.cm^2.nm) E E E E E E E E E E E E E E E E E E E E SMR (latest available)[ ] Page 15 of 18
16 SMR PMD :24: :25: E E E E14 photons/(s.cm^2.nm) E E E E E E E PMD-P (latest available)[ ] PMD-S (latest available)[ ] Scan motor torque statistics :00: :00: Nm Time Page 16 of 18
17 Torque profile - - Scan mirror pos statistics :00: :00: degree Time Page 17 of 18
18 Scan mirror position :00: :00:00 degree :00: No data loaded Time [ ] Scan mirror pos diff to ref Input data gaps :00: :59:59 MON1B Input MON1A Input L1B Input L1A Input L0 input MDR 1B MDR 1A 01:00 03:00 05:00 07:00 09:00 11:00 13:00 15:00 17:00 19:00 21:00 23:00 Page 18 of 18
Temporal coverage :00: :59:59 NAME RECORD FIELD TH VALUE STATUS ACTION
GOME-2 Metop-A NRT Quality Monitoring of the GOME-2 FM3 Instrument and Level 1A,B products Daily report Start orbit End orbit 59715 59731 Issue date 2018-04-24 04:02:00 Temporal coverage 2018-04-23 00:00:00
More informationGOME-2 Factsheet. Doc.No. : EUM/OPS/DOC/10/1299 Issue : v4d e-signed Date : 27 April 2017 WBS/DBS : EUMETSAT
Doc.No. : EUM/OPS/DOC/10/1299 Issue : v4d e-signed Date : 27 April 2017 WBS/DBS : EUMETSAT Eumetsat-Allee 1, D-64295 Darmstadt, Germany Tel: +49 6151 807-7 Fax: +49 6151 807 555 http://www.eumetsat.int
More informationIASI on MetOp-B Radiometric Calibration
IASI on MetOp-B Radiometric Calibration V. Lonjou 1, E. Péquignot 1, L. Buffet 1, J. Chinaud 1, S. Gaugain 1, E. Jacquette 1, D. Jouglet 1, C. Larigauderie 1, C. Villaret 1, J. Donnadille 2, B. Tournier
More informationThe IASI Instrument. on the assimilation of IASI in NWP Reading, May 6-8, ECMWF / NWP-SAF Workshop ! "# $ !" #$%& #$!$$
The IASI Instrument ECMWF / NWP-SAF Workshop on the assimilation of IASI in NWP Reading, May 6-8, 2009! "# $!" #$%& #$!$$ '($$)$$ Outline 1. Introduction 2. Functional Behaviour & Availability 3. Radiometric
More informationProduct Specification Document of the GOME Data Processor
Deutsches Zentrum für Luft und Raumfahrt e.v. of the GOME Processor July 31, 2002 Deutsches Zentrum für Luft und Raumfahrt e.v. DLR Institut für Methodik der Fernerkundung IMF Oberpfaffenhofen, Germany
More informationMeteosat Third Generation (MTG) Lightning Imager (LI) instrument performance and calibration from user perspective
Meteosat Third Generation (MTG) Lightning Imager (LI) instrument performance and calibration from user perspective Marcel Dobber, Jochen Grandell EUMETSAT (Darmstadt, Germany) 1 Meteosat Third Generation
More informationTES Algorithm Status. Helen Worden
TES Algorithm Status Helen Worden helen.m.worden@jpl.nasa.gov Outline TES Instrument System Testing Algorithm updates One Day Test (ODT) 2 TES System Testing TV3-TV19: Interferometer-only thermal vacuum
More informationCRISM (Compact Reconnaissance Imaging Spectrometer for Mars) on MRO. Calibration Upgrade, version 2 to 3
CRISM (Compact Reconnaissance Imaging Spectrometer for Mars) on MRO Calibration Upgrade, version 2 to 3 Dave Humm Applied Physics Laboratory, Laurel, MD 20723 18 March 2012 1 Calibration Overview 2 Simplified
More informationSAC-D/Aquarius. HSC - Radiometric Calibration H Raimondo M Marenchino. An Observatory for Ocean, Climate and Environment
An Observatory for Ocean, Climate and Environment SAC-D/Aquarius HSC - Radiometric Calibration H Raimondo M Marenchino 1 Buenos Aires April 11-13, 2012 HSC - Switchable ranges Ø HSC is a versatile instrument.
More informationSuomi NPP CrIS Reprocessed SDR Long-term Accuracy and Stability
Suomi NPP CrIS Reprocessed SDR Long-term Accuracy and Stability Yong Chen 1, Yong Han, Likun Wang 1, Fuzhong Weng, Ninghai Sun, and Wanchun Chen 1 CICS-MD, ESSIC, University of Maryland, College Park,
More informationCrIS SDR Calibration and Cross-sensor Comparisons
CrIS SDR Calibration and Cross-sensor Comparisons Yong Han NOAA Center for Satellite Applications and Research, College Park, MD, USA and CrIS SDR Science Team ITSC-19 March 25 April 1, 2014 Jeju Island,
More informationOTO Photonics. Sidewinder TM Series Datasheet. Description
OTO Photonics Sidewinder TM Series Datasheet Description SW (Sidewinder TM ) Series spectrometer,built with the InGaAs type sensor and high performance 32bits RISC controller in, is specially designed
More informationIce Cover and Sea and Lake Ice Concentration with GOES-R ABI
GOES-R AWG Cryosphere Team Ice Cover and Sea and Lake Ice Concentration with GOES-R ABI Presented by Yinghui Liu 1 Team Members: Yinghui Liu 1, Jeffrey R Key 2, and Xuanji Wang 1 1 UW-Madison CIMSS 2 NOAA/NESDIS/STAR
More informationGEOG 4110/5100 Advanced Remote Sensing Lecture 2
GEOG 4110/5100 Advanced Remote Sensing Lecture 2 Data Quality Radiometric Distortion Radiometric Error Correction Relevant reading: Richards, sections 2.1 2.8; 2.10.1 2.10.3 Data Quality/Resolution Spatial
More informationRevision History. Applicable Documents
Revision History Version Date Revision History Remarks 1.0 2011.11-1.1 2013.1 Update of the processing algorithm of CAI Level 3 NDVI, which yields the NDVI product Ver. 01.00. The major updates of this
More informationMERIS US Workshop. Vicarious Calibration Methods and Results. Steven Delwart
MERIS US Workshop Vicarious Calibration Methods and Results Steven Delwart Presentation Overview Recent results 1. CNES methods Deserts, Sun Glint, Rayleigh Scattering 2. Inter-sensor Uyuni 3. MOBY-AAOT
More informationDr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD (301) (301) fax
Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD 20723 (301) 953-6871 (301) 953-6670 fax Understand the instrument. Be able to convert measured counts/pixel on-orbit into
More informationAssessments of MODIS On-orbit Spatial and Spectral Characterization
EOS Assessments of MODIS On-orbit Spatial and Spectral Characterization Jack Xiong, Dan Link, Kevin Twedt, and Ben Wang NASA GSFC, Greenbelt, MD 0, USA SSAI, 00 Greenbelt Road, Lanham, MD 00, USA Acknowledgements
More informationReprocessing of Suomi NPP CrIS SDR and Impacts on Radiometric and Spectral Long-term Accuracy and Stability
Reprocessing of Suomi NPP CrIS SDR and Impacts on Radiometric and Spectral Long-term Accuracy and Stability Yong Chen *1, Likun Wang 1, Denis Tremblay 2, and Changyong Cao 3 1.* University of Maryland,
More informationMHS Instrument Pre-Launch Characteristics
MHS Instrument Pre-Launch Characteristics Jörg Ackermann, EUMETSAT, October 2017 The main objective of satellite instruments pre-launch characterisation is to ensure that the observed instrument performance
More informationProduct Specification Document of the GOME Data Processor
Deutsches Zentrum für Luft und Raumfahrt e.v. of the GOME Processor December 15, 2004 Deutsches Zentrum für Luft und Raumfahrt e.v. DLR Institut für Methodik der Fernerkundung IMF Oberpfaffenhofen, Germany
More informationBeginner s Guide to VIIRS Imagery Data. Curtis Seaman CIRA/Colorado State University 10/29/2013
Beginner s Guide to VIIRS Imagery Data Curtis Seaman CIRA/Colorado State University 10/29/2013 1 VIIRS Intro VIIRS: Visible Infrared Imaging Radiometer Suite 5 High resolution Imagery channels (I-bands)
More information7.1 Advanced Himawari Imager (AHI) Design and Operational Flexibility Dr. Paul C. Griffith
7.1 Advanced Himawari Imager (AHI) Design and Operational Flexibility Dr. Paul C. Griffith 12th Annual Symposium on New Generation Operational Environmental Satellite Systems This document is not export
More informationUtilization of AGI STK and S-NPP Operational Data to Generate JPSS-1 Proxy Test Data
Utilization of AGI STK and S-NPP Operational Data to Generate JPSS-1 Proxy Test Data Emily Greene Wael Ibrahim Chris van Poollen Ed Meletyan Scott Leszczynski 2018 AMS Annual Meeting Austin, TX, USA Copyright
More informationModeling of the ageing effects on Meteosat First Generation Visible Band
on on Meteosat First Generation Visible Band Ilse Decoster, N. Clerbaux, J. Cornelis, P.-J. Baeck, E. Baudrez, S. Dewitte, A. Ipe, S. Nevens, K. J. Priestley, A. Velazquez Royal Meteorological Institute
More informationPolar Multi-Sensor Aerosol Product: User Guide
Polar Multi-Sensor Aerosol Product: User Guide Doc.No. : EUM/TSS/MAN/14/742654 Issue : V2 e-signed Date : 8 January 2016 WBS : EUMETSAT Eumetsat-Allee 1, D-64295 Darmstadt, Germany Tel: +49 6151 807-7
More informationSPICAM Archive Tutorial. Principal Investigator : J.L. Bertaux Archive Manager : A. Reberac
SPICAM Archive Tutorial Principal Investigator : J.L. Bertaux Archive Manager : A. Reberac 1 SPICAM Archive Tutorial SPICAM Instrument SPICAM data levels/products SPICAM Archive volume set organization
More informationSummary of Publicly Released CIPS Data Versions.
Summary of Publicly Released CIPS Data Versions. Last Updated 13 May 2012 V3.11 - Baseline data version, available before July 2008 All CIPS V3.X data versions followed the data processing flow and data
More informationDescription of NOMAD Observation Types and HDF5 Datasets NOT YET COMPLETE
NOMAD Science Team KONINKLIJK BELGISCH INSTITUUT VOOR RUIMTE-AERONOMIE INSTITUT ROYAL D AERONOMIE SPATIALE DE BELGIQUE ROYAL BELGIAN INSTITUTE OF SPACE AERONOMY KONINKLIJK BELGISCH INSTITUUT VOOR RUIMTE-AERONOMIE
More informationChallenges in data compression for current and future imagers and hyperspectral sounders
Challenges in data compression for current and future imagers and hyperspectral sounders Nigel Atkinson (Met Office) ITSC-19, Jeju, 28 March 2014 or How to store your satellite data without needing too
More informationS2 MPC Data Quality Report Ref. S2-PDGS-MPC-DQR
S2 MPC Data Quality Report Ref. S2-PDGS-MPC-DQR 2/13 Authors Table Name Company Responsibility Date Signature Written by S. Clerc & MPC Team ACRI/Argans Technical Manager 2015-11-30 Verified by O. Devignot
More informationHow GOSAT has provided uniform-quality spectra and optimized global sampling patterns for seven years
IWGGMS -12 Session II: SWIR Spectroscopy & Retrieval Algorithms How GOSAT has provided uniform-quality spectra and optimized global sampling patterns for seven years June 7, 2016, Kyoto Akihiko KUZE, Kei
More informationSupplementary materials of Multispectral imaging using a single bucket detector
Supplementary materials of Multispectral imaging using a single bucket detector Liheng Bian 1, Jinli Suo 1,, Guohai Situ 2, Ziwei Li 1, Jingtao Fan 1, Feng Chen 1 and Qionghai Dai 1 1 Department of Automation,
More informationGOCI Post-launch calibration and GOCI-II Pre-launch calibration plan
Breakout Session: Satellite Calibration, IOCS Meeting 2015, 18 June 2015. GOCI Post-launch calibration and GOCI-II Pre-launch calibration plan Seongick CHO Korea Ocean Satellite Center, Korea Institute
More informationSDG1400 User s Guide
SDG1400 User s Guide Model SDG1400 Rate Sensor Systron Donner Inertial Sales and Customer Service Phone: +1 925.979. 4500 Fax: +1 925.349.1366 E-Mail: sales@systron.com www.systron.com SDG1400 User s Guide
More informationVIIRS Radiance Cluster Analysis under CrIS Field of Views
VIIRS Radiance Cluster Analysis under CrIS Field of Views Likun Wang, Yong Chen, Denis Tremblay, Yong Han ESSIC/Univ. of Maryland, College Park, MD; wlikun@umd.edu Acknowledgment CrIS SDR Team 2016 CICS
More informationASTER User s Guide. ERSDAC Earth Remote Sensing Data Analysis Center. 3D Ortho Product (L3A01) Part III. (Ver.1.1) July, 2004
ASTER User s Guide Part III 3D Ortho Product (L3A01) (Ver.1.1) July, 2004 ERSDAC Earth Remote Sensing Data Analysis Center ASTER User s Guide Part III 3D Ortho Product (L3A01) (Ver.1.1) TABLE OF CONTENTS
More informationResults of Cross-comparisons using multiple sites
Results of Cross-comparisons using multiple sites Dave Smith CEOS WGCV IVOS workshop 18-20 Oct 2010 1 Content AATSR Drift Analysis AATSR vs. MERIS comparisons over Deserts Intercomparisons Over Dome-C
More informationEvaluation of Satellite Ocean Color Data Using SIMBADA Radiometers
Evaluation of Satellite Ocean Color Data Using SIMBADA Radiometers Robert Frouin Scripps Institution of Oceanography, la Jolla, California OCR-VC Workshop, 21 October 2010, Ispra, Italy The SIMBADA Project
More information430g Dimensions. 102mm x 84mm x 59mm Detector nm Pixels 3648 Pixel size. 8μm x 200μm Pixel well depth
Weigth 430g Dimensions 102mm x 84mm x 59mm Detector Toshiba TCD1304DG linear array Detector range 200-1200nm Pixels 3648 Pixel size 8μm x 200μm Pixel well depth 100,000 electrons Signal-to-noise ratio
More informationFalse Color to NDVI Conversion Precision NDVI Single Sensor
False Color to NDVI Conversion Precision NDVI Single Sensor Contents 1 Sensor Properties... 2 2 Isolating Bands... 2 3 Calculating NDVI from Original Image Pixel DN... 3 4 Calculating NDVI from AgVault
More informationSturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold
L-LAS Series L-LAS-LT-85-RA-CL (Reduced Amplification) - Operates in an angle of total reflection - Suitable für high-glossy objects (e.g. glass) - Line laser
More informationSCIAMACHY. Level 0 to 1b Processing. Input / Output Data Definition
SCIAMACHY Level 0 to 1b Processing Input / Output Data Definition 14. July 2009 Deutsches Zentrum für Luft- und Raumfahrt e.v. - DLR Deutsches Fernerkundungsdatenzentrum - DFD Oberpfaffenhofen Germany
More informationInteractive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al.
Atmos. Meas. Tech. Discuss., www.atmos-meas-tech-discuss.net/5/c741/2012/ Author(s) 2012. This work is distributed under the Creative Commons Attribute 3.0 License. Atmospheric Measurement Techniques Discussions
More informationInteractive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al.
Atmos. Meas. Tech. Discuss., 5, C741 C750, 2012 www.atmos-meas-tech-discuss.net/5/c741/2012/ Author(s) 2012. This work is distributed under the Creative Commons Attribute 3.0 License. Atmospheric Measurement
More informationMERIS Instrument Status
MERIS Instrument Status presented by Stefan Weiß Photo: Courtesy Alcatel Space Industries Page 1 MERIS Instrument Status Functional Description & Hardware overview Functional check-out & Operations Telemetry
More informationSimulation and Analysis of an Earth Observation Mission Based on Agile Platform
Simulation and Analysis of an Earth Observation Mission Based on Agile Platform Augusto Caramagno Fabrizio Pirondini Dr. Luis F. Peñín Advanced Projects Division DEIMOS Space S.L. -1 - Engineering activities
More informationMonoVista CRS+ Raman Microscopes
MonoVista CRS+ Benefits Deep UV to NIR wavelength range Up to 4 integrated multi-line lasers plus port for large external lasers Dual beam path for UV and VIS/NIR Motorized Laser selection Auto Alignment
More informationOnboard Blackbody Calibration Algorithm of Chinese FY-2 Geostationary Imager Based on GSICS Reference Radiances
Onboard Blackbody Calibration Algorithm of Chinese FY-2 Geostationary Imager Based on GSICS Reference Radiances Xiuqing (Scott) Hu 1,4, Likun Wang 2, Fuzhong Weng 3, and Na Xu 4 1. ERT@NOAA/NESDIS/STAR,
More informationOtO Photonics. Sidewinder TM Series Datasheet. Description
OtO Photonics Sidewinder TM Series Datasheet Description SW (Sidewinder TM ) Series spectrometer,built with the InGaAs type sensor and high performance 32bits RISC controller in, is specially designed
More informationCalibration Techniques for NASA s Remote Sensing Ocean Color Sensors
Calibration Techniques for NASA s Remote Sensing Ocean Color Sensors Gerhard Meister, Gene Eplee, Bryan Franz, Sean Bailey, Chuck McClain NASA Code 614.2 Ocean Biology Processing Group October 21st, 2010
More informationSnow cover change detection with laser scanning range and brightness measurements
Snow cover change detection with laser scanning range and brightness measurements Sanna Kaasalainen, Harri Kaartinen, Antero Kukko, Henri Niittymäki Department of Remote Sensing and Photogrammetry 5th
More informationSCIAMACHY Command Line Tool Software User's Manual (SUM)
SCIAMACHY Command Line Tool Software User's Manual (SUM) SCIAMACHY Level 1b to 1c processing SciaL1c Page 2 of 71 Distribution List Name Affiliation Copies A. Dehn ESA-ESRIN 1 T. Fehr ESA-ESRIN 1 B. Aberle
More informationENHANCEMENT OF DIFFUSERS BRDF ACCURACY
ENHANCEMENT OF DIFFUSERS BRDF ACCURACY Grégory Bazalgette Courrèges-Lacoste (1), Hedser van Brug (1) and Gerard Otter (1) (1) TNO Science and Industry, Opto-Mechanical Instrumentation Space, P.O.Box 155,
More informationRalf K. Heilmann CAT-GS: Critical-Angle Transmission Grating Spectrometer January 27,
Ralf K. Heilmann CAT-GS: Critical-Angle Transmission Grating Spectrometer January 27, 2009 1 Overview of CAT-GS Mission requirements: Effective area > 1000 cm 2 (0.3 1 kev) Spectral resolution E/ΔE > 3000
More informationModern Surveying Techniques. Prof. S. K. Ghosh. Department of Civil Engineering. Indian Institute of Technology, Roorkee.
Modern Surveying Techniques Prof. S. K. Ghosh Department of Civil Engineering Indian Institute of Technology, Roorkee Lecture - 12 Rectification & Restoration In my previous session, I had discussed regarding
More informationPolar Multi-Sensor Aerosol Product: ATBD
Polar Multi-Sensor Aerosol Product: ATBD Doc.No. : EUM/TSS/SPE/14/739904 Issue : v3b e-signed Date : 30 November 2015 WBS : EUMETSAT Eumetsat-Allee 1, D-64295 Darmstadt, Germany Tel: +49 6151 807-7 Fax:
More informationSWAP Image Calibration. Daniel B. Seaton, D. Shaun Bloomfield, ROB & TCD SWAP Teams
SWAP Image Calibration Daniel B. Seaton, D. Shaun Bloomfield, ROB & TCD SWAP Teams Primary Image Calibration Steps Implemented Dark Subtraction Pixel Map Correction Image Scaling, Rotation, & Centering
More informationSPIcam: an overview. Alan Diercks Institute for Systems Biology 23rd July 2002
SPIcam: an overview Alan Diercks Institute for Systems Biology diercks@systemsbiology.org 23rd July 2002 1 Outline Overview of instrument CCDs mechanics instrument control performance construction anecdotes
More informationFrequently Asked Questions: excelon Back Illuminated CCD/EMCCD Cameras
Frequently Asked Questions: excelon Back Illuminated CCD/EMCCD Cameras 1. What is excelon? excelon is a new CCD/EMCCD sensor technology jointly developed by Princeton Instruments, e2v and Photometrics.
More informationSentinel-3 OLCI: Status
Sentinel-3 OLCI: Status Jens Nieke, F. Borde, C. Mavrocordatos OLCI Status 26 Nov 2013 ESRIN 1 Outline Background OLCI development status Assembly, Testing & Integration (AIT) Camera EM and FM test results
More informationIASI spectral calibration monitoring on MetOp-A and MetOp-B
IASI spectral calibration monitoring on MetOp-A and MetOp-B E. Jacquette (1), B. Tournier (2), E. Péquignot (1), J. Donnadille (2), D. Jouglet (1), V. Lonjou (1), J. Chinaud (1), C. Baque (3), L. Buffet
More informationKaguya s HDTV and Its Imaging
Kaguya s HDTV and Its Imaging C h a p t e r 2 Overview of the HDTV System In addition to Kaguya s 13 science instruments, the HDTV was unique in being specifically included to engage the public in the
More informationRaman Spectrometer Installation Manual
RI Raman Spectrometer Instruction Manual Application software (included in standard configuration) Connection RI RAMAN is recognized by Windows operational system as standard HID device. That is why there
More informationMTG-FCI: ATBD for Clear Sky Reflectance Map Product
MTG-FCI: ATBD for Clear Sky Reflectance Map Product Doc.No. Issue : : v2 EUMETSAT Eumetsat-Allee 1, D-64295 Darmstadt, Germany Tel: +49 6151 807-7 Fax: +49 6151 807 555 Date : 14 January 2013 http://www.eumetsat.int
More informationENMAP RADIOMETRIC INFLIGHT CALIBRATION
ENMAP RADIOMETRIC INFLIGHT CALIBRATION Harald Krawczyk 1, Birgit Gerasch 1, Thomas Walzel 1, Tobias Storch 1, Rupert Müller 1, Bernhard Sang 2, Christian Chlebek 3 1 Earth Observation Center (EOC), German
More informationPrototyping GOES-R Albedo Algorithm Based on MODIS Data Tao He a, Shunlin Liang a, Dongdong Wang a
Prototyping GOES-R Albedo Algorithm Based on MODIS Data Tao He a, Shunlin Liang a, Dongdong Wang a a. Department of Geography, University of Maryland, College Park, USA Hongyi Wu b b. University of Electronic
More informationSPECTRAL IMAGING VIEWER SOFTWARE MANUAL
103 Quality Circle, Suite 215 Huntsville, AL 35806 Phone: (256) 704-3332 Fax: (256) 971-2073 E-Mail: info@axometrics.com Website: http://www.axometrics.com SPECTRAL IMAGING VIEWER SOFTWARE MANUAL 2012
More informationFC Series Traffic Camera. Architect & Engineering Specifications
FC Series Traffic Camera Architect & Engineering Specifications This document is controlled to FLIR Technology Level 1. The information contained in this document pertains to a dual use product controlled
More informationNIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection
Powered by LightField The NIRvana: 64ST from Princeton Instruments is the world s first scientific grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy
More informationMinimizes reflection losses from UV - IR; Optional AR coatings & wedge windows are available.
Now Powered by LightField PyLoN:100 1340 x 100 The PyLoN :100 is a controllerless, cryogenically-cooled CCD camera designed for quantitative scientific spectroscopy applications demanding the highest possible
More informationSCIAMACHY Command Line Tool SciaL1c Software User s Manual
SCIAMACHY Command Line Tool SciaL1c Software User s Manual Issue 2/B Page 2 of 62 Distribution Name Affiliation Copies Name Affiliation Copies Thorsten Fehr ESA/ESRIN 1 Bernd Aberle DLR 1 Rob Koopman ESA/ESRIN
More informationManual Software R-LAS-LT-Scope (LT-Scope) V1.1
Manual Software R-LAS-LT-Scope (LT-Scope) V1.1 (PC software for Microsoft Windows 7, 8, 10) for Laser Reflection Sensor R-LAS-LT-110-HD2 This manual describes the installation process of the software for
More informationSee more with the NEW testo 880 thermal imager
Committing to the future See more with the NEW testo 880 thermal imager NEW! SEE MORE......OFFER MORE. Infrared radiation cannot be seen by the human eye. All objects whose temperature is above absolute
More informationEPS Product Validation Report: IASI L1 PCC PPF
EPS Product Validation Report: IASI L1 PCC PPF Doc.No. : Issue : v2 Date : 5 August 2010 EUMETSAT Eumetsat-Allee 1, D-64295 Darmstadt, Germany Tel: +49 6151 807-7 Fax: +49 6151 807 555 http://www.eumetsat.int
More informationWorking with M 3 Data. Jeff Nettles M 3 Data Tutorial at AGU December 13, 2010
Working with M 3 Data Jeff Nettles M 3 Data Tutorial at AGU December 13, 2010 For Reference Slides and example data from today s workshop available at http://m3dataquest.jpl.nasa.gov See Green et al. (2010)
More informationRadiance, Irradiance and Reflectance
CEE 6100 Remote Sensing Fundamentals 1 Radiance, Irradiance and Reflectance When making field optical measurements we are generally interested in reflectance, a relative measurement. At a minimum, measurements
More informationSentinel-1 Toolbox. TOPS Interferometry Tutorial Issued May 2014
Sentinel-1 Toolbox TOPS Interferometry Tutorial Issued May 2014 Copyright 2015 Array Systems Computing Inc. http://www.array.ca/ https://sentinel.esa.int/web/sentinel/toolboxes Interferometry Tutorial
More informationGeometric Rectification of Remote Sensing Images
Geometric Rectification of Remote Sensing Images Airborne TerrestriaL Applications Sensor (ATLAS) Nine flight paths were recorded over the city of Providence. 1 True color ATLAS image (bands 4, 2, 1 in
More informationMODIS Atmosphere: MOD35_L2: Format & Content
Page 1 of 9 File Format Basics MOD35_L2 product files are stored in Hierarchical Data Format (HDF). HDF is a multi-object file format for sharing scientific data in multi-platform distributed environments.
More informationSYNCERITY TM 1024 x 256
ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING SYNCERITY TM 1024 x 256 Open-Electrode TE-Cooled CCD
More informationS-NPP CrIS Full Resolution Sensor Data Record Processing and Evaluations
S-NPP CrIS Full Resolution Sensor Data Record Processing and Evaluations Yong Chen 1* Yong Han 2, Likun Wang 1, Denis Tremblay 3, Xin Jin 4, and Fuzhong Weng 2 1 ESSIC, University of Maryland, College
More informationThermal Imaging Solutions
2016 PRODUCT CATALOGUE Thermal Imaging Solutions www.tanzsecurity.com FL SERIES FL-A Series Focus : Motorized lens Pan : NA Tilt : NA Presets : NA Weight : 2 Kg. Size : 130x96x305mm. FL-B Series Focus
More informationSoftware requirements * : Part III: 2 hrs.
Title: Product Type: Developer: Target audience: Format: Software requirements * : Data: Estimated time to complete: Mapping snow cover using MODIS Part I: The MODIS Instrument Part II: Normalized Difference
More informationLight Tec Scattering measurements guideline
Light Tec Scattering measurements guideline 1 Our Laboratory Light Tec is equipped with a Photometric Laboratory (a dark room) including: Goniophotometers: REFLET180s. High specular bench (10 meters),
More informationSL 200 instrument can process the energy intensity emitted by the solar radiation in a precise place of the earth.
Solarimeter SL 200 Table of contents 1 Introduction...4 2 General information...4 2.1 Measured units...4 2.2 Use...4 3 Operating principle...5 3.1 Keyboard presentation...5 3.2 Instrument offers 3 groups
More informationCreating Situational Awareness with Spacecraft Data Trending and Monitoring
Creating Situational Awareness with Spacecraft Data Trending and Monitoring Zhenping Li ASRC Technical Services, Zhenping.Li@asrcfederal.com J.P. Douglas, and Ken Mitchell ASRC Technical Services, JPaul.Douglas@noaa.gov
More informationEasy integration into complex experimental setup
NIRvana: 64ST The NIRvana: 64ST from Princeton Instruments is the world s first scientific grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy applications.
More informationMachine learning approach to retrieving physical variables from remotely sensed data
Machine learning approach to retrieving physical variables from remotely sensed data Fazlul Shahriar November 11, 2016 Introduction There is a growing wealth of remote sensing data from hundreds of space-based
More informationSentinel-2 Calibration and Validation : from the Instrument to Level 2 Products
Sentinel-2 Calibration and Validation : from the Instrument to Level 2 Products Vincent Lonjou a, Thierry Tremas a, Sophie Lachérade a, Cécile Dechoz a, Florie Languille a, Aimé Meygret a, Olivier Hagolle
More informationImprovements to Ozone Mapping Profiler Suite (OMPS) Sensor Data Record (SDR)
Improvements to Ozone Mapping Profiler Suite (OMPS) Sensor Data Record (SDR) *C. Pan 1, F. Weng 2, T. Beck 2 and S. Ding 3 * 1 ESSIC, University of Maryland, College Park, MD 20740; 2 NOAA NESDIS/STAR,
More informationVIIRS-CrIS Mapping. P. Brunel, P. Roquet. Météo-France, Lannion. CSPP/IMAPP USERS GROUP MEETING 2015 EUMETSAT Darmstadt, Germany
VIIRS-CrIS Mapping P. Brunel, P. Roquet Météo-France, Lannion CSPP/IMAPP USERS GROUP MEETING 2015 EUMETSAT Darmstadt, Germany Introduction Mapping? Why? Mapping sounder and imager is of high interest at
More informationSpectral and Radiometric Design of a 3- line CCD Camera for Mars Observation
Spectral and Radiometric Design of a 3- line CCD Camera for Mars Observation Spectral Design Requirements: spectral range bandwidth spectral characteristics Design: 1. first approach by filter selection
More informationLLA Instruments GmbH. Multiplexed Near-Infrared-Spectrometer KUSTA 4004M. Product description
LLA Instruments GmbH Multiplexed Near-Infrared-Spectrometer KUSTA 4004M Product description General information KUSTA 4004 series The Near- Infrared Spectrometer, in short NIR-Spectrometer, KUSTA 4004
More informationRetrieval of Sea Surface Temperature from TRMM VIRS
Journal of Oceanography, Vol. 59, pp. 245 to 249, 2003 Short Contribution Retrieval of Sea Surface Temperature from TRMM VIRS LEI GUAN 1,2 *, HIROSHI KAWAMURA 1 and HIROSHI MURAKAMI 3 1 Center for Atmospheric
More informationThe Council for Optical Radiation Measurements (CORM), NIST July 30 - Aug 1, 2018
Study of the optical properties of black materials at solar reflective wavelengths in support of instrument development and satellite sensor calibration 1Jinan Zeng, 2 Nathan Kelley, 3 James J. Butler,
More informationCORRECTING RS SYSTEM DETECTOR ERROR GEOMETRIC CORRECTION
1 CORRECTING RS SYSTEM DETECTOR ERROR GEOMETRIC CORRECTION Lecture 1 Correcting Remote Sensing 2 System Detector Error Ideally, the radiance recorded by a remote sensing system in various bands is an accurate
More informationUsing Python with Smoke and JWST Mirrors. Warren Hack, Perry Greenfield, Babak Saif, Bente Eegholm Space Telescope Science Institute
Using Python with Smoke and JWST Mirrors Warren Hack, Perry Greenfield, Babak Saif, Bente Eegholm Space Telescope Science Institute The James Webb Space Telescope (JWST) will be the next NASA Great Observatory
More informationIMAGING SPECTROMETER DATA CORRECTION
S E S 2 0 0 5 Scientific Conference SPACE, ECOLOGY, SAFETY with International Participation 10 13 June 2005, Varna, Bulgaria IMAGING SPECTROMETER DATA CORRECTION Valentin Atanassov, Georgi Jelev, Lubomira
More informationFrequently Asked Questions: Princeton Instruments excelon TM CCD and EMCCD Cameras
Frequently Asked Questions: Princeton Instruments excelon TM CCD and EMCCD Cameras Updated: Sep 2010 Includes information on excelon TM Back-illuminated Deep Depletion Cameras 1. What is excelon TM? excelon
More information