1 FAQ Connecting to IGS NT FAQ Connecting to IGS-NT via RS232
2 FAQ Connecting to IGS NT Table of Contents 1 Preface Software Requirements Hardware Requirements Connecting to IGS - NT How to established connection Controller address, InteliGen NT Controller address InteliGen NT /Sys NT BaseBox using IV Controller address InteliGen NT /Sys NT BaseBox using IV InteliMonitor... 9
3 1 Preface For download any file from our website you will need registration in ComAp club Software Requirements InteliMonitor GenConfig Hardware Requirements Null Modem Cable (requirements on picture 1) Picture 1. Null modem cable requirements. Direct serial port or USB serial adaptor 3
4 2 Connecting to IGS - NT 2.1 How to established connection 1. Ensure null modem cable is connected to PC either directly to DB-9 Port or via USB serial adaptor. With the controller is connected to the RS232 DB-9 Port. Picture 1. Wiring of power supply (green circle) and RS232 connection (orange circle) of InteliGen NT (on the left) and InteliGen NT BaseBox (on the right). 2. Ensure 8-36 VDC is applied to the IGS NT. 3. Verify which COM port is being utilized in PC: a. Click on the Start button. b. Select CONTROL PANEL. c. Click Switch to Classic View. d. Select System. Picture 2. System Properties. 4
5 e. Once the system properties window comes up, click on the Hardware tap. f. Click on Device Manager. g. Click the + button to expand Ports (COM & LPT). h. Identify which com port is being used. (Picture 3.). If no com port appears in the list, it will be necessary to verify the connection of the NULL Modem Cable, power is supplied to the controller, and that the proper driver is installed if a USB to serial adaptor is being used. Picture 3. Device Manager. 5
6 2.1.1 Controller address, InteliGen NT Verify the Controller Address and RS232(1) Mode: a. At the IGS-NT controller press ESC key to access the Menu screen. b. Press the down arrow key until the cursor is on Setpoint and press ENT. c. Press the down arrow key until the cursor is on Comms settings and press ENT. d. Note the Value for Contr. Address. e. Ensure RS232(1) is set to Direct. Picture 5. InteliGen NT. f. Press the down arrow key until RS485(1) conv. is displayed. g. Ensure RS485(1) conv. is set to disabled. 6
7 2.1.2 Controller address InteliGen NT /Sys NT BaseBox using IV5 Verify the Controller Address and RS232(1) Mode: a. at the InteliVision 5 press Menu button. b. Press the down Arrow key until the cursor is on Setpoints. c. Press Enter button. d. Press the down arrow key until the cursor is on Comm Settings. e. Note the value for Contr. Address. f. Ensure RS232(1) is set to Direct. a. b. + d. b. + d. Picture 6. IV5 screen + IG-NT-BB 7
8 2.1.3 Controller address InteliGen NT /Sys NT BaseBox using IV8 Verify the Controller Address and RS232(1) Mode: a. at the InteliVision 8 press tool button. b. Press the context buttons according the Comm Settings. c. Note the value for Contr. Address. d. Ensure RS232(1) is set to Direct. a. c. + d. b. Picture 6. InteliVision 8 + IG-NT-BB. 8
9 2.2 InteliMonitor If the com port is identified open the InteliMonitor. a. Select connection open connection. Picture 7. InteliMonitor window. b. Select the COM port and open connection. Picture 8. InteliMonitor Open connection window. 9
10 c. Communication with the IGS-NT controller should now be established. You can confirm that on the bottom of the InteliMonitor window you can see Connection: Direct, Dde server: Running and it is displayed green. See on picture 9. Picture 9. Running connection between PC and IGS-NT controller. ComAp a.s. Kundratka 2359/17, , Prague 8, Czech Republic 10 (+420)
COMMUNICATION GUIDE. Communication Guide for ComAp Controllers. IGS-NT SW version 3.0
Communication Guide for ComAp Controllers InteliGen NT InteliGen NTC InteliGen NT BaseBox InteliGen NTC BaseBox InteliSys NT InteliSys NTC BaseBox Inteli Mains NT Inteli Mains NT BaseBox Inteli Mains NTC
More informationInteliGen InteliSys InteliMains
InteliGen InteliSys InteliMains Communication Guide for ComAp Controllers Copyright 2017 ComAp a.s. Prague, Czech Republic ComAp a.s., U Uranie 1612/14a, 170 00 Praha 7, Czech Republic Tel: +420 246 012
More informationInteliDrive Family Getting started
InteliDrive InteliDrive Family Getting started Compact Controllers for Diesel and Gas Engines InteliDrive October 2009 InteliDrive Family Getting started Copyright 2009 ComAp s.r.o. Written by Ladislav
More informationFW Murphy Millennium Controller File Transfer Guide using MTransfer v January 7, 2013
FW Murphy Millennium Controller File Transfer Guide using MTransfer v1.4.16 January 7, 2013 1.0 General Information 1.1 The Millennium controller uses PRJ files which contain the display program and may
More informationREFERENCE GUIDE. Copyright 2008 ComAp a.s.
GenConfig Configuration Tool for Gen-set controllers To be used with ComAp controllers from following product lines: InteliGen-NT, InteliSys-NT, InteliMains-NT SW version 3.0, June 2013 REFERENCE GUIDE
More informationREFERENCE GUIDE. Copyright ComAp s.r.o.
IB-Lite Plug-in Ethernet module To be used with ComAp controllers: IL MRSXX, IL AMFXX, IL-NT MRSXX, IL-NT AMFXX, IC-NT SPtM, IC-NT MINT, MC-NT, ID-Lite and other controllers based on these platforms SW
More informationREFERENCE GUIDE. Copyright 2008 ComAp a.s.
InteliMonitor Monitoring and SCADA software To be used with ComAp controllers from following product lines: InteliGen, InteliSys, InteliLlite, InteliGen-NT, InteliSys-NT, InteliLite-NT, InteliCompact-NT,
More informationControl Systems Product Overview
Control Systems Product Overview Gen-set controllers InteliLite NT MRS InteliLite NT MRS models are integrated controllers for single engine control in Manual and Remote Start applications, featuring full
More informationTier 4 Trends USB import & export. Configurable buttons
CONTROLLER COLOUR DISPLAY UNIT Description is a colour display unit designed as a simple, easy-to-use Plug and Play solution and delivers high visibility of all engine data, monitoring information and
More informationInternetBridge NT. Reference Guide. Internet Module. SW version 2.2.0
InternetBridge NT Internet Module Reference Guide SW version 2.2.0 Table Of Contents 2 1 General information 4 2 System overview 5 3 Installation and wiring 7 4 Module setup 16 5 Functions 28 6 Troubleshooting
More informationCOMMUNICATION GUIDE. InteliLite-NT InteliCompact-NT InteliATS-NT. InteliCommunication Guide for ComAp Controllers. December 2009
InteliCommunication Guide for ComAp Controllers InteliLite-NT InteliCompact-NT InteliATS-NT December 2009 COMMUNICATION GUIDE Copyright 2008 ComAp s.r.o. Kundratka 2359/17, 180 00 Praha 8, Czech Republic
More informationREFERENCE GUIDE. Copyright 2008 ComAp s.r.o.
PC Software for Gen-set Controllers LiteEdit Monitoring Tool for ComAp Controllers To be used with ComAp controllers: IL MRSXX, IL AMFXX, IL-NT MRSXX, IL-NT AMFXX, IC-NT SPtM, IC-NT MINT, MC-NT and derived
More informationInteliDrive DCU Marine
InteliDrive InteliDrive DCU Marine Expandable engine controller with electronic engines support Single speed applications Variable speed application AUX, EME, CMB PRP SW version 2.2, April 2014 Reference
More informationc InteliGen NTC general purpose HIGH-END gen set controller
G E N - S E T C O N T R O L L E R S / H I G H - E N D InteliGen nt is a comprehensive controller f both single and multiple gen-sets operating in standby parallel modes. Compact construction is optimized
More informationLiteEdit 2.0. User guide. Configuration and Monitoring Tool. PC Software for InteliLite Controllers. SW version 2.0, August 2004
PC Software for InteliLite Controllers LiteEdit 2.0 Configuration and Monitoring Tool SW version 2.0, August 2004 User guide Copyright 2004 ComAp s.r.o. Written by Ladislav Kadaník Prague, Czech Republic
More informationInteliPro. Protection Relay for Parallel Applications. Technical Specification
InteliPro Protection Relay for Parallel Applications Product description InteliPro is a highly flexible interconnection/mains decoupling protective relay with extensive protective functions. It meets the
More informationAccessory Modules. Reference Guide. Extension modules for IL-NT, IC-NT, ID-Lite genset or engine controllers, IA-NT. April ComAp, spol. s r.o.
Extension modules for IL-NT, IC-NT, ID-Lite genset or engine controllers, IA-NT Accessory Modules April 2011 Reference Guide ComAp, spol. s r.o. Kundratka 2359/17, 180 00 Praha 8, Czech Republic Tel: +420
More informationTROUBLESHOOTING GUIDE
DEKRACertification Compact Controller for Stand-by and Parallel Operating Gen-sets InteliGen NT, InteliSys NT, InteliMains NT Modular Controller Troubleshooting guide IG-NT, IG-NTC, IG-NT-BB, IG-NTC-BB,
More informationImprovements: Improves the sound performance when feedback is present.
EPSON PRODUCT SUPPORT BULLETIN Date: 12/24/2009 Originator: esc PSB #: Authorization: Reference: TI09-68e Rev. A and B Total Pages: 8 Product(s): AP-60 Projector Sound Solution Subject: Firmware Update
More informationConfiguration Mita WP3000
Configuration Mita WP3000 1. Table of contents 1. Table of contents... 2 2. Introduction... 3 3. Mita - WP3000... 4 4. Cables... 6 4.1. WP3000... 6 5. Four Faith F2403 GPRS Signal monitoring... 7 PS-Data
More informationREFERENCE GUIDE. MainsCompact NT P Mains controller for the InteliCompact gen-set controllers. SW version 1.0, March Copyright 2008 ComAp s.r.o.
MainsCompact NT P Mains controller for the InteliCompact gen-set controllers SW version 1.0, March 2009 REFERENCE GUIDE Copyright 2008 ComAp s.r.o. ComAp, spol. s r.o. Kundratka 17, 180 00 Praha 8, Czech
More informationConfiguration Instructions for icap with DOS Captivator
Configuration Instructions for icap with DOS Captivator Introduction: DOS-based Cheetah Captivator may be used to transmit caption data to HD480 encoders via the icap system. Instead of using the traditional
More informationInteliPro. Installation and Operation Guide Application Guide Communication Brochure Reference Guide. Protection Relay for Parallel Applications
InteliPro Protection Relay for Parallel Applications Comprehensive Guide SW version 1.6, November 2014 Installation and Operation Guide Application Guide Communication Brochure Reference Guide Copyright
More informationOperator Guide. InteliGen 200. Controller for parallel gen-set applications
InteliGen 200 Controller for parallel gen-set applications SW version 1.1.0 1 Front panel elements 2 2 Display screens and pages structure 5 3 Browsing alarms 21 4 Password 22 5 Information screen 29 6
More informationInteliNano NT. Operator Guide. Copyright 2011 ComAp s.r.o.
InteliNano NT Operator Guide Copyright 2011 ComAp s.r.o. ComAp, spol. s r.o. Kundratka 17, 180 00 Praha 8, Czech Republic Tel: +420 246 012 111, Fax: +420 266 316 647 E-mail: info@comap.cz, www.comap.cz
More informationHow to connect. Go to Tools / Options / Port Settings (in PlusConfig software) and change the COM port to COM 3. Minelec PlusConfig How to connect
How to connect PlusConfig How to connect with the Luxom system There are 3 different ways of connecting your computer to the Luxom system: - LOCAL - IP - MODEM LOCAL This means that we use a Luxom serial
More informationFSA-CU Configuration Utility Programming Guide
FSA-CU Configuration Utility Programming Guide Revision 3 October 2013 Introduction The following guide will show you the basics of the FSA-CU configuration utility program. The CU can be used with the
More informationSelect a Data Communication Interface
Printer Setup and Operation Select a Data Communication Interface Select a Data Communication Interface You may connect your print engine to a computer using one or more of the available connections. The
More informationConfiguration DCE TAC-I
Configuration DCE TAC-I 1. Table of contents 1. Table of contents... 2 2. Introduction... 3 3. Communication ports... 4 4. Parameters... 5 4.1. NEG Micon, Vestas - TAC I... 6 4.2. NTK / Nordtank / Wincon
More informationIn addition, REWIND can be used to set a connection with the monitoring software SICES SUPERVSIOR.
REWIND: Electronic device that, using GSM/GPRS technology and being connected to a genset, a tower light, a tank, etc., automatically sends data to a central software called SI.MO.NE (Sices Monitor Network).
More informationInteliLite NT MRS. Reference Guide. Modular Gen-set Controller. InteliLite NT. Compact Controller for Single Operating Gen-sets
InteliLite NT InteliLite NT MRS Modular Gen-set Controller Compact Controller for Single Operating Gen-sets (IL-NT MRS10/11/15/16 unit) SW version 2.2, September 2014 Reference Guide Copyright 2014 ComAp
More informationPINNACLE TYPE DEKO CG
FASTRACK TECH NOTE Version..0 & later 4/0/0 CABLE CONNECTIONS PINNACLE TYPE DEKO CG The Deko has two () RS Com ports labeled COM 1 and COM. It is possible to connect to the Fastrack using one of following
More informationInteliCompact NT EASY TO USE PARALLELING CONTROLLER. Description. Benefits
EASY TO USE PARALLELING CONTROLLER Benefits Simple paralleling (easy wiring, installation and configuration) Remote moniting helps reduce call-out costs of service engineers Optional Internet with control
More informationInteliLite NT AMF. Reference Guide. Modular Gen-set Controller. InteliLite NT. Compact Controller for Stand-by Operating Gen-sets
InteliLite NT InteliLite NT AMF Modular Gen-set Controller Compact Controller for Stand-by Operating Gen-sets (IL-NT AMF20/25 unit) SW version 2.1, November 2012 Reference Guide Copyright 2012 ComAp s.r.o.
More informationData Acquisition Software and Hardware Demonstration Guide
Data Acquisition Software and Hardware Demonstration Guide For: NetDAQ Logger for Windows Hydra Logger for Windows Trend Link for Fluke Introduction This demonstration guide contains exercises designed
More informationInteliNano NT GEN-SET CONTROLLER. Description. Benefits MEMBER
GEN-SET CONTROLLER Description is a cost effective diesel and gasoline generator set controller which offers outstanding protection, monitoring and control for small and middle size generator sets. There
More informationInteliNano NT. MRS Lite GEN-SET CONTROLLER. Description. Benefits
GEN-SET CONTROLLER Description is a cost effective generator set controller which offers outstanding protection, monitoring and control for small and middle size generator sets. There are three different
More informationWIRELESS RF MODEM SETUP MANUAL FOR CARDMASTER
WIRELESS RF MODEM SETUP MANUAL FOR CARDMASTER REV 07.03.12 www.cardlockvending.com customers call 888-487-5040 Installation Manual for CardMaster Wireless modem setup 1 TABLE OF CONTENTS PAGE 1 INSTALLATION
More informationDriveConfig. User guide. InteliDrive PC software. InteliDrive. SW version 3.3, September 2013
InteliDrive DriveConfig InteliDrive PC software SW version 3.3, September 2013 User guide Copyright 2004-2013 Comp a.s. Written by Ladislav Kadanik, Pavel Doubek Prague, Czech Republic Comp a.s. Kundratka
More informationHOW TO USE MODEL A3LA-IGS TECHNICAL NOTE. December 6, 2004 PRELIMINARY. Copyright by NAL Research Corporation
TN2004-20-V3.2 HOW TO USE MODEL A3LA-IGS TECHNICAL NOTE December 6, 2004 PRELIMINARY Copyright 2003-2004 by NAL Research Corporation The specifications in this document are subject to change at NAL Research
More informationSerial 2-Port ExpressCard
Serial 2-Port ExpressCard User Manual Ver. 2.00 All brand names and trademarks are properties of their Respective owners. Features and Benefits Fully compliant with ExpressCard Specification 1.0 ExpressCard/34
More informationThor Guard to ThorPCX Connection SUPPORT DOCUMENT
1 THOR GUARD TO THORPCX CONNECTION One vital step when setting up the ThorPCX and ThorMobile software is the connection between your Thor Guard Lightning Prediction unit and the computer running ThorPCX.
More informationAssigning COM Port Numbers to the Serial Ports of a USBto-Serial
Assigning COM Port Numbers to the Serial Ports of a USBto-Serial Adapter A Technical Application Note from Doppler Systems May 6, 2008 1.0 Introduction USB-to-serial converters have an interesting and
More informationOPERATOR GUIDE. InteliGen NT, InteliSys NT Modular Gen-set Controller. Operator guide for SPI, SPtM, MINT, COX
Compact Controller for Stand-by and Parallel Operating Gen-sets InteliGen NT, InteliSys NT Modular Gen-set Controller Operator guide for SPI, SPtM, MINT, COX IG-NT, IG-NTC, IG-EE, IG-EEC, IS-NT Software
More informationUsing Music Port with Home Automation Systems
Using Music Port with Home Automation Systems This paper describes how to use the NuVo Music Port in conjunction with an automation controller that needs access to the RS232 port on the NuVo amplifier.
More informationOperating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!
Operating Bulletin Model BB3-232 and BB3-I-232 USB Multi-Drop Box The Fastest Flow Controller Company in the World! 1 10/16/2017 Rev.1 DOC-BB3232MAN 2 Introduction Alicat BB3-232 Multi-Drop Box Operating
More informationASSAN ESC PC Interface Software User s Guide
ASSAN ESC PC Interface Software User s Guide Dear customer, Welcome to use ASSAN ESC PC Connector and Interface Software. It allows of the Electronic Speed Controller programming in the desktop PC and
More informationPRoDUCt GUIDe. software and pc tools product accessories mains protection products electronic potentiometers product comparison table.
PRoDUCt GUIDe leader in gen set communication solutions control systems electronic edition section ii. software and pc tools product accessories mains protection products electronic potentiometers product
More informationIndustrial 4G LTE Cellular Gateway ICG-2420-LTE
Industrial 4G LTE Cellular Gateway ICG-2420-LTE Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Starting Web Management... 5 4. Terminal Setup... 8 4.1. Logon
More informationInteliATS NT. Reference Guide. Automatic Transfer Switch Controller. IA-NT STD unit. SW version 2.0, June 2010
InteliATS NT Automatic Transfer Switch Controller IA-NT STD unit SW version 2.0, June 2010 Reference Guide June 2010 Copyright 2010 ComAp s.r.o. Written by Vlastimil Vostřák Prague, Czech Republic ComAp,
More informationREFERENCE GUIDE. ID-Mobile Logger. Data Logger. HW version 1.4; SW version 1.8, February InteliDrive
InteliDrive ID-Mobile Logger Data Logger HW version 1.4; SW version 1.8, February 2013 REFERENCE GUIDE Copyright 2013 ComAp s.r.o. Written by KKMN Prague, Czech Republic ComAp, spol. s r.o. Kundratka 17,
More informationSimple Start Instructions HI/Beckwith M-2001C Regulator Control
HI Document 2.4.72, Revision 0 Simple Start Instructions HI/Beckwith M-2001C Regulator Control Howard Industries Utility Products Division Howard Industries, Inc. 3225 Pendorff Road Laurel, MS 39440 Phone:
More informationDirect Wire Downloading Set up and Troubleshooting for VISTA TURBO PANELS
Direct Wire Downloading Set up and Troubleshooting for VISTA TURBO PANELS Overview This document explains the required cable, accessories needed to direct connect to the security panel using Compass. As
More informationNew InteliSysNT. New InteliSysNT RELATED PRODUCTS. Worldwide references. Switzerland Generator room at Hotel Sandos, Quintana Roo.
New InteliSysNT ELATED PODUCTS InteliGenNT Colour IG-NT- Worldwide references New InteliMainsNT IM-NT- ALL IN ONE GEN-SET CONTOLLE Mains Supervision Contller InteliGenNT Colour is a comprehensive contller
More informationUSB-COM Plus ISO (USB-COMi SI-M)
VS Vision Systems GmbH / Part Number 603 Features 1 x RS232/422/485 port USB 2.0 Full Speed interface 2.5kV isolation per serial port USB and serial ports ESD protected Robust metal case Jumperless, DIP
More informationRemote announciator igl-ra15
Extension module for il/ig/is genset controllers Remote announciator igl-ra15 Version 1.1, August 2003 Prague, Czech Republic Copyright 2003 ComAp s.r.o. Written by: Jan Tomandl ComAp s.r.o. Svetova 7,
More informationIntegration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): Power Series / 5401
Manufacturer: DSC Integration Note Model Number(s): Power Series / 5401 Core Module Version: 4.0 (all builds) Comments: Document Revision Date: 1/30/2013 OVERVIEW AND SUPPORTED FEATURES The DSC Power Series
More informationIntegration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): DSC POWER SERIES / IT-100
Manufacturer: DSC Integration Note Model Number(s): DSC POWER SERIES / IT-100 Core Module Version: 6.4.209 Comments: Document Revision Date: 9/11/2013 OVERVIEW AND SUPPORTED FEATURES The DSC Power Series
More informationSenCom Jan. 11, 2013 Demonstration on Windows 7 Desktop, Windows Explorer & File Mgmt., and using Thumb/Flash Drives These topics by Mike Smith
SenCom Jan. 11, 2013 Demonstration on Windows 7 Desktop, Windows Explorer & File Mgmt., and using Thumb/Flash Drives These topics by Mike Smith Note: SenCom s 3 hour workshops, Files and Folders and Beginners
More informationUPort TM 1100 Series Quick Installation Guide
UPort TM 1100 Series Quick Installation Guide Edition 6.0, September 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationFrequently Asked Questions
Model 881 SPORTSCAN Digital Sidescan Sonar Frequently Asked Questions What can I use to power the SportScan? The SportScan requires a DC voltage between 10 and 16 volts for proper operation (+12VDC @ 0.5A
More informationTOTALFLOW Technical Bulletin 113
TOTALFLOW Technical Bulletin 113 Tuning ABB s Modbus Multivariable's Static Pressure Response Time Totalflow Technical Bulletin Version 1.0, Revision AD (7 January 2004) ABB Inc. ABB Inc. 7051 Industrial
More informationInteliCompact NT EASY TO USE PARALLELING CONTROLLER. Description. Benefits
EASY TO USE PARALLELING CONTROLLER Benefits Simple paralleling (easy wiring, installation and configuration) Remote moniting helps reduce call-out costs of service engineers Optional Internet with control
More informationGE-DSH-73/82 and 82-POE Managed Switch Installation Sheet
GE Security GE-DSH-73/82 and 82-POE Managed Switch Installation Sheet Package Contents Thank you for purchasing the GE Security 7/8-Port Fast Ethernet + 2/3-Port Gigabit TP/SFP Combo Managed Switch. The
More informationQuick Start. MS-9 Laser Scanner
Quick Start MS-9 Laser Scanner This guide is designed to get your scanner up and running quickly. When connected to a host computer with Windows operating system (2000 or above), you can use ESP (Easy
More informationIntegration Note. Any feature not specifically noted as supported should be assumed to be unsupported.
Integration Note Manufacturer: Model Number(s): Rotel T11 DAB Tuner (RS232) g! Core Module Version: 8.0.278 Driver Developer: Core Programming Limited Document Revision Date: 03/01/2017 Overview & Supported
More informationUSER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)
USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...
More informationModel Number(s): D7000, D9000 Series Panels, D7000/9000V2 Panels
Manufacturer: Bosch / Radionics Integration Note Model Number(s): D7000, D9000 Series Panels, D7000/9000V2 Panels Core Module Version: Comments: Tested Firmware Revisions: 6.80, 7.07 Document Revision
More informationCode Dynamics, Inc. Port Splitter
Code Dynamics, Inc. Port Splitter Thank you for purchasing the Port Splitter. With this product, you can utilize a single Andover port for both the modem and PC connections. This device connects to the
More informationUsing the Routing Demo program
This program is intended to demonstrate the audio routing capability of the Eventide H8000 family Harmonizer brand effects processors. In the following text, these will be referred to as H8000, though
More informationInteliLite NT SINGLE SET GEN-SET CONTROLLER. Description. Benefits
SINGLE SET GEN-SET CONTROLLER Description The range offers a wide choice of integrated control solutions for gen-sets operating in single standby mode. Based on the field proven InteliLite architecture,
More informationHOW TO USE MODEL A3LA-I TECHNICAL NOTE
TN2004-39-V3.2 HOW TO USE MODEL A3LA-I TECHNICAL NOTE December 6, 2004 Copyright 2004 by NAL Research Corporation The specifications in this document are subject to change at NAL Research s discretion.
More informationSMEMA Extension Module
SMEMA Extension Module for PC assisted board transfer (Installation manual) Thank you for choosing our products and services! Currently, ICCO EMT represents the most important supplier for manufacturers
More informationInteliLite NT SINGLE SET GEN-SET CONTROLLER. Description. Benefits
SINGLE SET GEN-SET CONTROLLER Description The range offers a wide choice of integrated control solutions for gen-sets operating in single standby mode. Based on the field proven InteliLite architecture,
More information8-Port 10/100Mbps + 2G TP/SFP Combo. Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT
8-Port 10/100Mbps + 2G TP/SFP Combo Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements...
More informationEthernet HMi RAC and Gateway Setup Instructions Rev. 09
Ethernet HMi RAC and Gateway Setup Instructions Rev. 09 Table of Contents Preparing a PXG-900 Gateway...2 Preparing an ELC-CAENET Module... 7 Configuring the HMi RAC... 10 Preparing the ATC-300+... 13
More informationUSB SERIAL ADAPTOR COM PORT INSTRUCTIONS
USB SERIAL ADAPTOR COM PORT INSTRUCTIONS No part of this work covered by the copyright hereon may be reproduced, copied, transferred or distributed in any form or by any means -- graphic, electronic, or
More informationUSB to serial converters do not use the standard Microsoft serial driver, and so cannot be used with FTS.
Known Devices Compatible with FTS FTS asynchronous products use a custom driver compatible with the standard serial driver supplied with Windows 95/98, Windows Me, Windows NT, Windows 2000 and Windows
More informationALL-IN-ONE.NT GENERATOR & CHP CONTROL SYSTEM FIRMWARE IS-NT-AFR / 2.2 OPERATING MANUAL
ALL-IN-ONE.NT GENERATOR & CHP CONTROL SYSTEM FIRMWARE IS-NT-AFR 2.3.1 / 2.2 OPERATING MANUAL MOTORTECH Gas Engine Control Systems P/N 01.30.008-EN Rev. 09/2016 Copyright Copyright 2016 MOTORTECH GmbH.
More informationCuteLine AIN8 UI - Voltage Current. Manual
CuteLine AIN8 UI - Voltage Current Manual Doc.-No. : Version : 1.1 Date of Issue : HUEGLI TECH Switzerland This document, and the information contained herein is the intellectual property of HUEGLI TECH.
More informationHow to test the USBLE232D and USBLE232DEXA Serial Bluetooth Smart Low Energy Adapter
How to test the USBLE232D and USBLE232DEXA Serial Bluetooth Smart Low Energy Adapter (Tested with Samsung Galaxy S8 Android and Windows 10) This guide describes how to connect one of our Serial Bluetooth
More informationELAD EXTIO-232 CAT RS232 interface with band output for FDM-DUO
ELAD EXTIO-232 CAT RS232 interface with band output for FDM-DUO USER MANUAL www.eladit.com Contents Revision History... 3 1 Overview... 4 2 CAT Commands... 4 3 Band Select Output... 5 4 Firmware Upgrade...
More informationM-Logger Copyright 2011 DGSI. All Rights Reserved.
M-Logger 58810199 Copyright 2011 DGSI. All Rights Reserved. This equipment should be installed, maintained, and operated by technically qualified personnel. Any errors or omissions in data, or the interpretation
More informationIMPORTANT! GE Caddx panels cannot support PIN codes then end in zero over RS-232. See Common Mistakes for more information.
Manufacturer: GE NetworX Integration Note Model Number(s): NX-4,6,8 Core Module Version: Document Revision Date: 01/09/2016 OVERVIEW AND SUPPORTED FEATURES The NetworX NX-4,6,8 security panels integrate
More informationUSB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual
USB to RS-232/RS422/485 US-101-I USB To Serial Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel Views Description
More informationMODEL SELECTION WPM CURRENT RANGE (A) RS-232C 1 115Vac A 120VL-L
WIDEBAND POWER METER DESCRIPTION The Model WPM wideband power meter measures and displays voltage, current, power and energy parameters for single-phase or three-phase systems. Applications include measurement
More informationData Acquisition. Software and Hardware. Demonstration Guide. For: NetDAQ Logger for Windows Hydra Logger for Windows Trend Link for Fluke
Data Acquisition Software and Hardware Demonstration Guide For: NetDAQ Logger for Windows Hydra Logger for Windows Trend Link for Fluke Introduction This demonstration guide contains exercises designed
More informationUSB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features
USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual The USB-COMi-TB USB-to-Industrial Single RS-422/485 Adapter is designed to make industrial communication port expansion quick and simple.
More informationREFERENCE GUIDE IS NT BF. Inteli New Technology. Modular Gen-set Bi-fuel Controller. Conversion Kit Software Configuration.
InteliSys-NT IS NT BF Inteli New Technology Modular Gen-set Bi-fuel Controller Conversion Kit Software Configuration SW version 1.0.3, December 2008 REFERENCE GUIDE Copyright 2008 ComAp s.r.o. ComAp, spol.
More informationIndustrial L2+ Multi-Port Full Gigabit. Managed Ethernet Switch IGS T2S/IGS UP1T2S IGS P2S/IGS P4S/IGS P2T2S
Industrial L2+ Multi-Port Full Gigabit Managed Ethernet Switch IGS-5225-4T2S/IGS-5225-4UP1T2S IGS-5225-8P2S/IGS-5225-8P4S/IGS-5225-8P2T2S Quick Installation Guide Table of Contents 1. Package Contents...
More informationQuick Start Guide. MS-820 Industrial Bar Code Scanner
Quick Start Guide MS-820 Industrial Bar Code Scanner This guide is designed to get your scanner up and running quickly. When connected to a host computer with Windows operating system (98 or above), you
More informationGlobal Guide. WebSupervisor. Web Based System for Monitoring and Controlling
WebSupervisor Web Based System for Monitoring and Controlling SW version 4.0.0 1 Document information 4 2 System overview 7 3 Operator guide 8 4 Appendix 72 Copyright 2016 ComAp a.s. Written by Lukas Smol
More informationUSB SERIAL ADAPTOR COM PORT INSTRUCTIONS
USB SERIAL ADAPTOR COM PORT INSTRUCTIONS No part of this work covered by the copyright hereon may be reproduced, copied, transferred or distributed in any form or by any means -- graphic, electronic, or
More informationPower, efficiency and safety on the water That s smart control. Marine and offshore solutions
Power, efficiency and safety on the water That s smart control Marine and offshore solutions Engine Management System ComAp Engine Management System is comprehensive control, monitoring and protection
More informationSCT 3000 USB-to-RS232 Converter Driver Installation Instructions
SCT 3000 USB-to-RS232 Converter Driver Installation Instructions 34-ST-33-61 March 2010 Note: This procedure applies to the USB to RS232 Converter only. If you are using the RS-232 Serial port, you do
More informationMODEL SELECTION PDM SERIAL COMM. 3 RS-485 *3. External RS-232C to USB adapter
POWER DISPLAY METER DESCRIPTION The Model PDM power display meter measures and displays voltage, current, power and energy parameters for single-phase or three-phase systems. Voltages up to 600Vac and
More informationIntroduction. 1 available USB type A (downstream) port. Windows 98, Windows ME, Windows 2000, Windows XP,
Introduction Thank you for ordering the USB-RS232 Converter. The USB-RS232 Converter is an intelligent, stackable expansion module that connects to a PC or server via the Universal Serial Bus (USB) port,
More information2018/03/23 12:00 1/2 Perle IOLAN
2018/03/23 12:00 1/2 Perle IOLAN Table of Contents Perle IOLAN... 1 Requirements... 1 Known Issues... 1 Configuraiton... 1 Lan Configuration... 1 Installation... 2 Serial Port... 2 DuVoice - http://support.duvoice.com/
More informationBioPointe Reader Installation Guide
BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial
More informationUSB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual
USB to RS-232/RS422/485 URK-228-I USB To Serial Operation Manual First Edition, Feb 2012 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel Views Description
More information