C HYPERSIM Acceptance Test Plan

Size: px
Start display at page:

Download "C HYPERSIM Acceptance Test Plan"

Transcription

1 C HYPERSIM Acceptance Test Plan Version: 3.2

2

3 Test Result Approval The undersigned acknowledge they have reviewed the steps in this Acceptance Test and agrees with the approach it presents. Changes to this Acceptance Test will be coordinated with and approved by the undersigned or their designated representatives. Signature: Date: / /

4

5 C HYPERSIM Acceptance Test Plan Page i CONTENTS 1. INTRODUCTION OBJECTIVES INSTRUCTIONS TEST STEPS FORMALISM PREREQUISITES SYSTEM CONFIGURATION SOFTWARE VERSIONS SYSTEM TESTS C SLAVE TEST WITH EXTERNAL TOOL PMUCONNECT FILE GENERATION C MASTER/SLAVE LOOPBACK TEST BETWEEN TWO SIMULATORS C MASTER/SLAVE LOOPBACK ON THE SAME SIMULATOR...18

6 C HYPERSIM Acceptance Test Plan Page 1/19 1. INTRODUCTION 1.1. OBJECTIVES This document aims at defining the acceptance tests that are to be executed to ensure the correct functionality of the C driver on HYPERSIM under Linux and Windows. It includes both the master and the slave parts of the protocol. The features that shall be tested are: C master application C slave application PMUConnect application 1.2. INSTRUCTIONS For most test cases, multiple files are provided. Before executing each case, be sure to copy the files in the right directories. File name hyservmain.cfg C37118_MASTER_SLAVE.io C37118_SLAVE.io C37118_MASTER.io C37118_MASTER_STANDALONE_CFG.opal C37118_MASTER_LOOPBACK_CFG.opal C37118_SLAVE_STANDALONE_CFG.opal C37118_SLAVE_LOOPBACK_CFG.opal *.sch, *.sig, *.xml 6.0.x Windows *.ecf, *.sig, *.xml Directory /export/local/ssr/hyconfig/ /export/local/ssr/hyconfig/ /export/local/ssr/hyconfig/ /home/hypusr01/hyworkspace/c37118/ C:\Users\UserName\HyperWorks\design\C37118 Note: The UserName is found by typing the following command in cmd.exe : echo %username%

7 C HYPERSIM Acceptance Test Plan Page 2/ TEST STEPS FORMALISM For each test, a header provides the test ID, as well as an extended description and the preliminary setup needed to accomplish the test. Each test step is identified with a number. A set of instructions is defined, along with the expected results, where applicable. Depending on what is observed, the status must be set. A check in the check box of the status column indicates test is complete. Some comments can be added at the end of each test to provide some extra information. ID Description Setup TEST STEPS # Instructions Expected results Status Comments

8 C HYPERSIM Acceptance Test Plan Page 3/19 2. PREREQUISITES The Acceptance Test Plan lists all the tests that must be executed to validate the good functionality of the system. It is important to: Read the System Description Document provided in the delivery binder. Be familiar with HYPERSIM and other software products needed for the tests. Understand the delivered hardware SYSTEM CONFIGURATION System #1 (S01) Gr. 1 Gr. 2 Gr. 3 Gr. 4 System #2 (S02) Gr. 1 Gr. 2 Gr. 3 Gr. 4 Section A Section B Section A Section B 4 x DCDC +/-18V 833mA 2 x DCDC +/-12V 625mA 4 x DCDC +/-18V 833mA 2 x DCDC +/-12V 625mA MOTHERBOARD 1 PCI-E 2.0 x8 (in x16) 2 PCI-E 2.0 x4 (in x8) 3 PCI-E 2.0 x8 4 PCI-E 1.0 x4 (in x8) PCI 33MHz (32 bits) 5 PCI 33MHz (32 bits) 6 CPU CPU CPU X.XX GHz X GB X GB 5 6 Vout: 5V, 12V 600W Power Supply 115V to 230V Simulator Ethernet MOTHERBOARD 1 PCI-E 2.0 x8 (in x16) 2 PCI-E 2.0 x4 (in x8) 3 PCI-E 2.0 x8 4 PCI-E 1.0 x4 (in x8) PCI 33MHz (32 bits) 5 PCI 33MHz (32 bits) 6 CPU CPU CPU X.XX GHz X GB X GB 5 6 Vout: 5V, 12V 600W Power Supply 115V to 230V Simulator Ethernet Ethernet Switch Figure 1: System configuration needed to run all tests NOTE: The configuration shown is needed to perform test C37118_MS_Loop_2sim. If only one simulator is available, this test can be skipped. Here is a list of what is required to execute this test plan: HYPERSIM 5.6.x or higher: Host computer with MobaXterm installed A Netgear switch Linux target with HYPERSIM installed

9 C HYPERSIM Acceptance Test Plan Page 4/19 HYPERSIM 6.0.x Windows version: Host computer with MobaXterm installed A Netgear switch Linux target with HYPERSIM 6.0.x installed Windows Host with HYPERSIM 6.0.x installed 2.2. SOFTWARE VERSIONS The tests performed during the acceptance test have been done / are to be done with the following software versions: RTOS = Redhat opalrt-6.1 Linux version: HYPERSIM R5.8.2 Windows version: HYPERSIM R6.0.0.o270 PMU Connection Tester = 4.4.0

10 C HYPERSIM Acceptance Test Plan Page 5/19 3. SYSTEM TESTS 3.1. C SLAVE TEST WITH EXTERNAL TOOL ID C37118_Ext_Tool Description Verify that the C Slave protocol is functional with an external tool. Setup See the System Configuration section. Use simulator S01 only. Files Slave files in directory /C37_118/Model/Slave. TEST STEPS # Instructions Expected results Status 1 2 Linux version: Copy files from the /hyconfig/slave/ folder in the right directory (see Instructions section of this document) and restart the real-time server as a root user. Windows version: Copy files from the /hyconfig/slave/ folder in the right directory (see Instructions section of this document). service hy.server start Edit the C37118Slave_standalone_CFG.opal file and set the pmu_nic_name to the right Ethernet interface. Linux version: The configuration files are copied on the simulator and the real-time server has been restarted. Windows version: The configuration files are copied on the simulator. The Ethernet interface are set for the slave simulation. Failure in using correct values for this parameter prevents simulation from starting. 3 Linux version: Copy files from the /Model/Slave folder to the /home/hypusr01/hyworkspace/ C37118/ directory. Windows version: Copy files from the /Model/Slave folder to the C:\Users\UserName\HyperWorks \design\c37118_slave directory. Start HYPERSIM 6.0.x and edit the parameters of the real-time simulation. See example in the Figure 4 and Figure 5 Linux version: The model and associated files are copied on the simulator. Windows version: The model and associated files are copied on the Host and HYPERSIM is configured.

11 C HYPERSIM Acceptance Test Plan Page 6/ Linux version: Open the model C37118_SLAVE_MODEL.sch. Go to the Simulation mode and load sensor file C37118_SLAVE_SENSORS.sig. Start simulation. Windows version: Open the model C37118_SLAVE_MODEL.ecf. Go to HYPERSIM/Sensors tab and load sensor file C37118_SLAVE_SENSORS.sig. Start the simulation. Linux version: Launch HyperView and then Scopeview. Open template C37118_SLAVE_TEMPLATE.xml. Windows version: Launch Scopeview. Open template C37118_SLAVE_TEMPLATE.xml. In Windows, start the PMU Connection Tester application. In the Settings tab, under Application Settings, put the ForceIPv4 parameter to True and set PhaseAngleGraphStyle to Raw. In the Tcp tab, Put the simulator IPaddress and port number In the Protocol tab, set Device ID Code to 1, select in the drop-down list IEEE C , then click Connect. In PMU Connection Tester, click on Disconnect. Change the Port value for 7201 and the Device ID Code for 2 and reconnect. In PMU Connection Tester, click on Disconnect. The slave model runs on the simulator. ScopeView is launched and the template opened. Application started. ForceIPv4 is True. Connection is successful. Data is received. See Figure 2 to compare received data. Connection is lost. Connection is successful. Data is received. See Figure 2 to compare received data. Connection is lost. 12 Stop the slave model. Simulation has stopped. Comments For the pmu_nic_name, if it is unknown, use the command ifconfig as a root the get a list of available interfaces. It is typically between eth0 and eth5.

12 C HYPERSIM Acceptance Test Plan Page 7/19 Figure 2: Results obtained with the PMU Connection Tester

13 C HYPERSIM Acceptance Test Plan Page 8/ PMUCONNECT FILE GENERATION ID Description Setup Model PMUConnect Verify that the PMUConnect application is functional to generate the IO configuration files. See the System Configuration section. Use simulator S01 only. Slave files in directory /C37_118/Model/Slave TEST STEPS # Instructions Expected results Status 1 2 Copy the PMUConnect binary file to /export/local/ssr/hyconfig/ using the following command: The PMUConnect binary file is copied in the configuration directory. cp /export/local/ssr/hypersim/linux-rhel5-32-opalrt/hyserver/bin/pmuconnect /export/local/ssr/hyconfig/ Modify the LD_LIBRARY_PATH environment variable to add the /hyconfig/ directory. As root, use command: The LD_LIBRARY_PATH variable is modified. You can verify by typing env grep LD_LIBRARY_PATH export LD_LIBRARY_PATH=/export/local/ssr/hypersim/linux-rhel5-32- opalrt/hyserver/rt/lib/:/export/local/ssr/hypersim/linux-rhel5-32- opalrt/hyserver/rt/lib/drivers:${ld_library_path} Failure to do this step will result in the following error message while trying to run the PMUConnect: PMUConnect: error while loading shared libraries Launch the C slave model. Follow steps 1 to 4 of test C37118_Ext_Tool as a guideline. In a terminal window, make the working directory to be /hyconfig/ using command: cd /export/local/ssr/hyconfig/ Launch the PMUConnect application using the IP address of the simulator as argument: The C slave model runs on the simulator. The working directory is /hyconfig/. The PMUConnect application runs. See comments at the end of this test for an overview of the expected output../pmuconnect -ip x.x -name OpalRT-PMU1 -sensor_offset port 7200 It is possible that the application does not return to a functional command prompt after running. If the last line printed is Closing PMU connection, the user can stop the program using Ctrl+C.

14 C HYPERSIM Acceptance Test Plan Page 9/ Verify that immediately after the line: Initializing C Master, you have the line: Starting listening thread.. If instead you see the line: C37.118Master: Connection to PMU x.x failed; Use the previous configuration file, a connection problem has occurred. List the files located in the directory according to their creation/modification date using command: ls -ltr The connection could be established without any problem. The 4 files listed should have the same date and time and this date/time should match the date/time when you ran the PMUConnect application. The 4 files are: -PMU-OpalRT-PMU1.txt -PMU- OpalRT-PMU1.cfg2 If you rerun the command with the exact same arguments: -connections-pmu-opalrt-pmu1.io -C37118_master_cfg_01.opal -The C37118_master_cfg_01.opal file will be incremented instead of being overwritten. A new version will be created (C37118_master_cfg_02.opal, _03.opal, _04.opal, etc). 8 Stop the slave model. The model has stopped. Comments Step #4: If running the PMUConnect application on the same simulator as the slave model, the PMU IP-address must be set to (the localhost IP). Also modify the command in step #6 accordingly. Step #5: The expected output when running the PMUConnect application is: RTServer[hypusr01]86%./PMUConnect -ip name TEST1 - sensor_offset port 7200 Name TEST1 connectionslabel TEST1 Begin initialization Begin to register on OpalRoot

15 C HYPERSIM Acceptance Test Plan Page 10/19 Registered on OpalRoot Loading services from "/export/local/ssr/hyconfig/services" Service LogRT/LogRT not found Root initialized: :25251/resources/root Initialization done SyncExchangerManager : Exchanger C37118Master created Initializing C Master... Starting listening thread. Received CFG2 frame, processing Exporting CFG2 frame for PMU :7200 PMU timebase: (-> resolution: us) PMU number: 1 PMU 1: OpalRT-PMU1 Data format - FREQ/ROCOF format: floating point - analogs format: floating point - phasors format: 16-bit integer - phasors notation: polar phasor (2): V-PHASOR I-PHASOR analog (2): ANALOG-1 ANALOG-2 digital (2x16): DIG-1 00 DIG-1 01 DIG-1 02 DIG-1 03 DIG-1 04 DIG-1 05 DIG-1 06 DIG-1 07 DIG-1 08 DIG-1 09 DIG-1 10 DIG-1 11 DIG-1 12 DIG-1 13 DIG-1 14 DIG-1 15 DIG-2 00 DIG-2 01 DIG-2 02 DIG-2 03 DIG-2 04 DIG-2 05 DIG-2 06 DIG-2 07 DIG-2 08 DIG-2 09 DIG-2 10 DIG-2 11 DIG-2 12 DIG-2 13 DIG-2 14 DIG-2 15 Phasor conversion factors (2) * 10^-5 Volt * 10^-5 Ampere Analog conversion factors (2) - factor: 0, single point-on-wave - factor: 0, RMS Value Digital conversion factors (2)

16 C HYPERSIM Acceptance Test Plan Page 11/19 - normal state: 0x0, valid bits: 0x0 - normal state: 0x0, valid bits: 0x0 Nominal frequency: 50Hz Config change count: 0 Refresh rate: 20 frame/second - 0. ANALOG-1 at 0x80c8f30 (F32) - 1. ANALOG-1.factor at 0x80c9e7c (U32) - 2. ANALOG-2 at 0x80c8f34 (F32) - 3. ANALOG-2.factor at 0x80c9e84 (U32) - 4. ClockLocked at 0x80c8ea8 (Boolean) - 5. DIG-1 00 at 0xbfe1acf8 (PositionedBit<0>) - 6. DIG-1 01 at 0xbfe1acf8 (PositionedBit<1>) - 7. DIG-1 02 at 0xbfe1acf8 (PositionedBit<2>) - 8. DIG-1 03 at 0xbfe1acf8 (PositionedBit<3>) - 9. DIG-1 04 at 0xbfe1acf8 (PositionedBit<4>) DIG-1 05 at 0xbfe1acf8 (PositionedBit<5>) DIG-1 06 at 0xbfe1acf8 (PositionedBit<6>) DIG-1 07 at 0xbfe1acf8 (PositionedBit<7>) DIG-1 08 at 0xbfe1acf9 (PositionedBit<0>) DIG-1 09 at 0xbfe1acf9 (PositionedBit<1>) DIG-1 10 at 0xbfe1acf9 (PositionedBit<2>) DIG-1 11 at 0xbfe1acf9 (PositionedBit<3>) DIG-1 12 at 0xbfe1acf9 (PositionedBit<4>) DIG-1 13 at 0xbfe1acf9 (PositionedBit<5>) DIG-1 14 at 0xbfe1acf9 (PositionedBit<6>) DIG-1 15 at 0xbfe1acf9 (PositionedBit<7>) DIG-2 00 at 0xbfe1acf8 (PositionedBit<0>) DIG-2 01 at 0xbfe1acf8 (PositionedBit<1>) DIG-2 02 at 0xbfe1acf8 (PositionedBit<2>) DIG-2 03 at 0xbfe1acf8 (PositionedBit<3>) DIG-2 04 at 0xbfe1acf8 (PositionedBit<4>)

17 C HYPERSIM Acceptance Test Plan Page 12/ DIG-2 05 at 0xbfe1acf8 (PositionedBit<5>) DIG-2 06 at 0xbfe1acf8 (PositionedBit<6>) DIG-2 07 at 0xbfe1acf8 (PositionedBit<7>) DIG-2 08 at 0xbfe1acf9 (PositionedBit<0>) DIG-2 09 at 0xbfe1acf9 (PositionedBit<1>) DIG-2 10 at 0xbfe1acf9 (PositionedBit<2>) DIG-2 11 at 0xbfe1acf9 (PositionedBit<3>) DIG-2 12 at 0xbfe1acf9 (PositionedBit<4>) DIG-2 13 at 0xbfe1acf9 (PositionedBit<5>) DIG-2 14 at 0xbfe1acf9 (PositionedBit<6>) DIG-2 15 at 0xbfe1acf9 (PositionedBit<7>) Error at 0x80c8e2c (I32) FracSec at 0x80c8eb0 (U32) Freq at 0x80c9688 (F32) I-PHASOR.angle at 0x80c87ec (F32) I-PHASOR.factor at 0x80c8ffc (U32) I-PHASOR.magnitude at 0x80c87e8 (F32) ROCOF at 0x80c968c (F32) SOC at 0x80c8eac (U32) Stat.configChange at 0x80c9677 (Boolean) Stat.dataError at 0x80c9670 (I32) Stat.dataModified at 0x80c9678 (Boolean) Stat.dataSorting at 0x80c9675 (Boolean) Stat.inSync at 0x80c9674 (Boolean) Stat.timeQuality at 0x80c967c (I32) Stat.triggerReason at 0x80c9684 (I32) Stat.unlockedTime at 0x80c9680 (I32) Status at 0x80c8e28 (I32) Timebase at 0x80c8e78 (U32) V-PHASOR.angle at 0x80c87e4 (F32) V-PHASOR.factor at 0x80c8ff4 (U32) V-PHASOR.magnitude at 0x80c87e0 (F32) Saving Mapping points in /export/local/ssr/hyconfig/pmu-test1.txt

18 C HYPERSIM Acceptance Test Plan Page 13/19 Done Creating connections file for C Master test Adding SyncExchanger for the C37118 Master Offset The following driver configuration file (/export/local/ssr/hyconfig/c37118_master_cfg_01.opal) is used to generate (./connections-pmu-test1.opal) Closing PMU connection Exiting listening thread.

19 C HYPERSIM Acceptance Test Plan Page 14/ C MASTER/SLAVE LOOPBACK TEST BETWEEN TWO SIMULATORS ID Description C37118_MS_Loop_2sim Verify that the C protocol is functional in loopback between two distinct simulators (S01 and S02). Setup See the System Configuration section. Use simulators S01 and S02. Files TEST STEPS Use files in directory C37_118/Model/Slave and C37_118/Model/Master # Instructions Expected results Status 1 Linux version: On S02, copy files from the Slave folder in the right directories (see Instructions section of this document) and restart the realtime server as a root user. Windows version: On S02, copy files from the Slave folder in the right directories (see Instructions section of this document). service hy.server start Slave files are copied on S Launch the C slave model. Follow steps 2 to 5 of test C37118_Ext_Tool as a guideline. Linux version: On S01, copy files from the Master folder in the right directories (see Instructions section of this document) and restart the realtime server as a root user. Windows version: On S01, copy files from the Master folder in the right directories (see Instructions section of this document). service hy.server start On S01, edit the C37118Master_standalone_CFG.opal file and set the ip to the IP-address of the simulated PMU (Put the IPaddress of the Slave). The C slave model runs on simulator S02 and the template has been loaded in ScopeView. Master files are copied on S01. The IP-address is set for the master simulation. The IP-addresses set in step 2 and 4 should therefore be the same.

20 C HYPERSIM Acceptance Test Plan Page 15/ Linux version: Open the model C37118_MASTER_MODEL.sch. Go to the Simulation mode and load sensor file C37118_MASTER_SENSORS.sig. Start simulation. Windows version: Open the model C37118_MASTER_MODEL.ecf. Go to HYPERSIM/Sensors tab and load sensor file C37118_MASTER_SENSORS.sig. Start the simulation. Linux version: Launch HyperView and then Scopeview. Open template C37118_MASTER_TEMPLATE.xml. Windows version: Launch Scopeview. Open template C37118_MASTER_TEMPLATE.xml. The master model runs on S01. ScopeView is launched and the template opened. Expected results can be viewed on Figure 3. 7 Run an acquisition in both ScopeView instances. Analog_1: ± 1 sine wave, 1.5 Hz, discrete = 50 ms Analog_2: ± 2 sine wave, 1.5 Hz, discrete = 50 ms Digital_1: 1 Hz, 25% duty cycle Digital_2: 1 Hz, 75% duty cycle Freq_Dev: 50 ± 0.2 sine wave, 1 Hz, discrete = 50 ms Freq_ROC: ± 100 sine wave, 0.5 Hz, discrete = 50 ms VoltagePhasorAngle: ± pi sine wave, 1.5 Hz, discrete=50ms VoltagePhasorMagnitude: 4*** CurrentPhasorAngle: ± pi sine wave, 1.5 Hz, discrete=50ms CurrentPhasorMagnitude: 3*** *** The CurrentPhasor and the VoltagePhasor magnitudes values of 3 and 4 are expected on the master side. On the slave side, the values should be 3 and 4 respectively. The factor between the

21 C HYPERSIM Acceptance Test Plan Page 16/19 two is given by the parameter unit of the item in the pmu_phasors section of C37_118_slave_cfg_01.opal, where the equation is: Master reading = Slave value unit 10 5 In this acceptance test, the unit value is set to 100, Stop both the master and the slave models Comments Both models are stopped The results must be displayed both in the slave and in the master ScopeView acquisitions. If the results are shown only in the slave acquisition, it means the data are not properly exchanged from the slave to the master. Note also that the 50 ms discretization observed on the master side is normal and is due to the pmu_data_rate slave parameter set to 20 (cycles per seconds).

22 C HYPERSIM Acceptance Test Plan Page 17/19 Figure 3: C master model acquisition results

23 C HYPERSIM Acceptance Test Plan Page 18/ C MASTER/SLAVE LOOPBACK ON THE SAME SIMULATOR ID Description Setup Files C37118_MS_Loop_1sim Verify that the C protocol is functional in loopback on a single simulator. See the System Configuration section. Use simulator S01 only. Slave and Master files in directory /C37_118/Model/Master-Slave. TEST STEPS # Instructions Expected results Status Copy configuration files from the /hyconfig/master-slave folder in the right directory as well as the models (see Instructions section of this document). Only for Linux version: restart the real-time server as a root user. service hy.server start Linux version: Copy model from the Master- Slave folder to the /home/hypusr01/hyworkspace/ C37118_MasterSlave/ directory. Windows version: Copy files from the Master-Slave folder to the C:\Users\UserName\HyperWorks \design\c37118_masterslave directory. Start HYPERSIM 6.0.x and edit the parameters of the real-time simulation. See example in the Figure 4 and Figure 5 Linux version: Open HYPERSIM and open the model C37118_MASTER_SLAVE_MODEL.sch. Go to the Simulation mode and load sensor file C37118_MASTER_SLAVE_SENSORS.sig. Start simulation. Windows version: Open the model C37118_MASTER_SLAVE_MODEL.ecf. Go to HYPERSIM/Sensors tab and load sensor file C37118_MASTER_SLAVE_SENSORS.sig. Start the simulation. Configuration files are copied on the simulator. Model is copied in the right directory in the simulator. And HYPERSIM is configured for Windows version. The Master/Slave model runs.

24 C HYPERSIM Acceptance Test Plan Page 19/19 4 Launch HyperView and then Scopeview. Open template C37118_MASTER_SLAVE_TEMPLATE.xml. Windows version: Launch Scopeview. Open template C37118_MASTER_SLAVE_TEMPLATE.xml. 8 Run acquisition in ScopeView. ScopeView is launched and the template opened. Expected results are the same as in test C37118_MS_Loop_2sim in Figure 3. 9 Stop both master and slave models. Both models are stopped. Comments Note also that the 50 ms discretization observed on the master side is normal and is due to the pmu_data_rate slave parameter set to 20 (cycles per seconds).

25 C HYPERSIM Acceptance Test Plan Page 1/1 Figure 4: Target Configuration Figure 5: HYPERSIM Simulation Configuration

26

27 CONTACT Note: OPAL-RT Corporate Headquarters 1751 Richardson, Suite 2525 Montréal, Québec, Canada H3K 1G6 Tel.: Toll free: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. Technical Services 01/05/2017 OPAL-RT TECHNOLOGIES Inc.

Simulink S-Function for RT-LAB Document 1b Creation of a S-Function From C Code and Protection of the Source Code Version 1.2

Simulink S-Function for RT-LAB Document 1b Creation of a S-Function From C Code and Protection of the Source Code Version 1.2 Simulink S-Function for RT-LAB Document 1b Creation of a S-Function From C Code and Protection of the Source Code Version 1.2 www.opal-rt.com 1751 Richardson, suite 2525 Montréal (Québec) Canada H3K 1G6

More information

OP5332 USER GUIDE Isolated Digital to Analog Converter Module

OP5332 USER GUIDE Isolated Digital to Analog Converter Module OP5332 USER GUIDE Isolated Digital to Analog Converter Module www.opal-rt.com Published by OPAL-RT Technologies, Inc. 1751 Richardson, suite 2525 Montréal (Québec) Canada H3K 1G6 www.opal-rt.com 2017 OPAL-RT

More information

Creating a Virtual Machine with OPAL-RT Linux Version 1.5

Creating a Virtual Machine with OPAL-RT Linux Version 1.5 Creating a Virtual Machine with OPAL-RT Linux Version 1.5 www.opal-rt.com 1751 Richardson, suite 2525 Montréal (Québec) Canada H3K 1G6 www.opal-rt.com 2017 All rights reserved Printed in Canada Contents

More information

OP /32 Digital Inputs User Guide.

OP /32 Digital Inputs User Guide. OP5353 16/32 Digital Inputs User Guide www.opal-rt.com Published by OPAL-RT Technologies, Inc. 1751 Richardson, suite 2525 Montreal (Quebec) Canada H3K 1G6 www.opal-rt.com 2011 OPAL-RT Technologies, Inc.

More information

OP7816 DATASHEET Optically Isolated 16 Digital Inputs Signal Conditioning Module

OP7816 DATASHEET Optically Isolated 16 Digital Inputs Signal Conditioning Module OP7816 DATASHEET Optically Isolated 16 Digital Inputs Signal Conditioning Module www.opal-rt.com Published by Opal-RT Technologies, Inc. 1751 Richardson, suite 2525 Montreal, Quebec Canada H3K 1G6 www.opal-rt.com

More information

OP7361 DATASHEET. 8X SFP Carrier.

OP7361 DATASHEET. 8X SFP Carrier. OP7361 DATASHEET 8X SFP Carrier www.opal-rt.com Published by Opal-RT Technologies, Inc. 1751 Richardson, suite 2525 Montreal, Quebec Canada H3K 1G6 www.opal-rt.com 2013 Opal-RT Technologies, Inc. All rights

More information

Quick Start Guide for OP4200 Thank you for choosing RT-LAB as your real-time simulation platform.

Quick Start Guide for OP4200 Thank you for choosing RT-LAB as your real-time simulation platform. Quick Start Guide for OP4200 Thank you for choosing RT-LAB as your real-time simulation platform. This Quick Start Guide will guide you through the first steps in achieving real-time and closed-loop simulation,

More information

Quick Start Guide. Thank you for choosing RT-LAB as your real-time simulation platform.

Quick Start Guide. Thank you for choosing RT-LAB as your real-time simulation platform. Quick Start Guide Thank you for choosing RT-LAB as your real-time simulation platform. This Quick Start Guide will guide you through the first steps in achieving real-time and closed-loop simulation, while

More information

Quick Start Guide for the HYPERSIM Simulator

Quick Start Guide for the HYPERSIM Simulator Quick Start Guide for the HYPERSIM Simulator Version: 6.2 Date: 16/10/2017 www.opal-rt.com CONTENTS 1. INTRODUCTION... 1 1.1. REQUIRED MATERIAL...1 2. FIRST STEPS WITH HYPERSIM... 2 2.1. CREATE A SCHEMATIC...2

More information

OP8662 High Voltage and Current Probe User Guide.

OP8662 High Voltage and Current Probe User Guide. OP8662 High Voltage and Current Probe User Guide www.opal-rt.com Published by OPAL-RT Technologies, Inc. 1751 Richardson, suite 2525 Montreal, Quebec, Canada H3K 1G6 www.opal-rt.com 2011 OPAL-RT Technologies,

More information

Cisco UCS C-Series IMC Emulator Quick Start Guide. Cisco IMC Emulator 2 Overview 2 Setting up Cisco IMC Emulator 3 Using Cisco IMC Emulator 9

Cisco UCS C-Series IMC Emulator Quick Start Guide. Cisco IMC Emulator 2 Overview 2 Setting up Cisco IMC Emulator 3 Using Cisco IMC Emulator 9 Cisco UCS C-Series IMC Emulator Quick Start Guide Cisco IMC Emulator 2 Overview 2 Setting up Cisco IMC Emulator 3 Using Cisco IMC Emulator 9 Revised: October 6, 2017, Cisco IMC Emulator Overview About

More information

OP4510 RT-LAB-RCP/HIL SYSTEMS User Guide.

OP4510 RT-LAB-RCP/HIL SYSTEMS User Guide. OP4510 RT-LAB-RCP/HIL SYSTEMS User Guide www.opal-rt.com Published by OPAL-RT Technologies, Inc. 1751 Richardson, suite 2525 Montreal, Quebec, Canada H3K 1G6 www.opal-rt.com 2016 OPAL-RT Technologies,

More information

OP4510 V2 RT-LAB-RCP/HIL SYSTEM User Guide.

OP4510 V2 RT-LAB-RCP/HIL SYSTEM User Guide. OP4510 V2 RT-LAB-RCP/HIL SYSTEM User Guide www.opal-rt.com Published by OPAL-RT Technologies, Inc. 1751 Richardson, suite 2525 Montreal, Quebec, Canada H3K 1G6 www.opal-rt.com 2016 OPAL-RT Technologies,

More information

OP4520 FPGA PROCESSOR AND EXPANSION UNIT User Guide.

OP4520 FPGA PROCESSOR AND EXPANSION UNIT User Guide. OP4520 FPGA PROCESSOR AND EXPANSION UNIT User Guide www.opal-rt.com Published by OPAL-RT Technologies, Inc. 1751 Richardson, suite 2525 Montreal, Quebec, Canada H3K 1G6 www.opal-rt.com 2015 OPAL-RT Technologies,

More information

OP5700 USER MANUAL RCP/HIL/ FPGA-BASED REAL-TIME SIMULATOR.

OP5700 USER MANUAL RCP/HIL/ FPGA-BASED REAL-TIME SIMULATOR. OP5700 RCP/HIL/ FPGA-BASED REAL-TIME SIMULATOR USER MANUAL www.opal-rt.com Published by OPAL-RT Technologies, Inc. 1751 Richardson, suite 2525 Montréal (Québec) Canada H3K 1G6 www.opal-rt.com 2016 OPAL-RT

More information

MX-AOPC UA Server User s Manual

MX-AOPC UA Server User s Manual User s Manual Edition 3.3, February 2018 www.moxa.com/product 2018 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used

More information

ACE Operation Manual

ACE Operation Manual ACE Operation Manual Elecsys Director ACE Operation Manual Product Information Full information about other Elecsys products is available on our website at www.elecsyscorp.com Useful Contact Information

More information

IMC Network Traffic Analyzer 7.2 (E0401P04) Copyright 2016 Hewlett Packard Enterprise Development LP

IMC Network Traffic Analyzer 7.2 (E0401P04) Copyright 2016 Hewlett Packard Enterprise Development LP Network Traffic Analyzer 7.2 (E0401P04) Copyright 2016 Hewlett Packard Enterprise Development LP Table of Contents 1. What's New in this Release 2. Problems Fixed in this Release 3. Software Distribution

More information

Beginner's Guide for UK IBM systems

Beginner's Guide for UK IBM systems Beginner's Guide for UK IBM systems This document is intended to provide some basic guidelines for those who already had certain programming knowledge with high level computer languages (e.g. Fortran,

More information

Reference Pulse Generator Module User Guide

Reference Pulse Generator Module User Guide Reference Pulse Generator Module User Guide www.opal-rt.com Reference Pulse Generator Module OP6222 User Guide 2 INTRODUCTION REFERENCE PULSE GENERATOR MODULE Reference Pulse Generator Module Architecture

More information

Lab Working with Linux Command Line

Lab Working with Linux Command Line Introduction In this lab, you will use the Linux command line to manage files and folders and perform some basic administrative tasks. Recommended Equipment A computer with a Linux OS, either installed

More information

MX-AOPC UA Server User s Manual

MX-AOPC UA Server User s Manual User s Manual Edition 3.1, November 2016 www.moxa.com/product 2016 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used

More information

PCIe 10G SFP+ Network Card

PCIe 10G SFP+ Network Card PCIe 10G SFP+ Network Card User Manual Ver. 1.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2 Features...

More information

MAXSANTAFEEVSYS User Manual

MAXSANTAFEEVSYS User Manual MAXSANTAFEEVSYS User Manual Rev 0; 5/14 For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated s website at www.maximintegrated.com. Maxim

More information

IMC Network Traffic Analyzer 7.1 (E0301P04) Copyright (c) 2015 Hewlett-Packard Development Company, L.P. All Rights Reserved.

IMC Network Traffic Analyzer 7.1 (E0301P04) Copyright (c) 2015 Hewlett-Packard Development Company, L.P. All Rights Reserved. Network Traffic Analyzer 7.1 (E0301P04) Copyright (c) 2015 Hewlett-Packard Development Company, L.P. All Rights Reserved. Table of Contents 1. What's New in this Release 2. Problems Fixed in this Release

More information

Chipkin Chariot Quick Start Guide

Chipkin Chariot Quick Start Guide Toll Free: 1 866 383-1657 3381 Cambie St., #211 Vancouver, BC Canada V5Z 4R3 Chipkin Chariot Quick Start Guide Use this guide to quickly configure the Chariot to poll for BACnet IP data points and serve

More information

EAN- Startup Guide 3000-OEM

EAN- Startup Guide 3000-OEM EAN- Startup Guide 3000-OEM PN: EAN- Startup-Guide-3000-OEM Software Revision: v2.23.x 10/16/2017 SightLine Applications, Inc. Contact: Web: sightlineapplications.com Sales: sales@sightlineapplications.com

More information

Page 2 PragmaDev Studio V5.3

Page 2 PragmaDev Studio V5.3 INSTALLATION MANUAL Page 2 PragmaDev Studio V5.3 Contents Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 Description...2 FLEXlm architecture...3 PragmaDev

More information

Real-Time HIL/RCP Laboratory. Study, design and test power electronics control algorithms using both OPAL-RT and Lab-Volt solutions.

Real-Time HIL/RCP Laboratory. Study, design and test power electronics control algorithms using both OPAL-RT and Lab-Volt solutions. Real-Time HIL/RCP Laboratory Study, design and test power electronics control algorithms using both OPAL-RT and Lab-Volt solutions. Electric Motor Laboratory Curriculum Goals Laboratory Highlights and

More information

Cal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester. Users Guide. Rev 3.1

Cal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester. Users Guide. Rev 3.1 Cal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester Users Guide Rev 3.1 Contents... 1 Quick Start Guide... 2 Selecting a Test Specification... 3 Clearing Traces... 4 Saving Traces...4 Loading

More information

Real-time transient stability simulation tool

Real-time transient stability simulation tool ephasorsim: Real-time transient stability simulation tool Vahid Jalili-Marandi, Ph.D. OPAL-RT Technologies Vahidj@opal-rt.com 1 Large 10 000+ Nodes Wide Area Simulation ephasorsim Large EMT Simulation

More information

Engineering Data Management Software. User s Guide. CoCo DSA Mode Spider Real-Time Mode Post Analysis Mode (CoCo VDC Mode not included)

Engineering Data Management Software. User s Guide. CoCo DSA Mode Spider Real-Time Mode Post Analysis Mode (CoCo VDC Mode not included) EDM USER S MANUAL Engineering Data Management Software User s Guide CoCo DSA Mode Spider Real-Time Mode Post Analysis Mode (CoCo VDC Mode not included) Version 1.00 Crystal Instruments Corporation 4699

More information

DIGIOP ELEMENTS V8.7 NVR Software-only Installation Guide

DIGIOP ELEMENTS V8.7 NVR Software-only Installation Guide DIGIOP ELEMENTS V8.7 NVR Software-only Installation Guide About this installation guide Use this document as a guide to install your DIGIOP ELEMENTS NVR software system. It includes procedures to install

More information

FastTracker. Version 1.0 QuickStart Guide

FastTracker. Version 1.0 QuickStart Guide FastTracker Version 1.0 QuickStart Guide 1 Overview The Facilis FastTracker is a server and client application for cataloging, searching and viewing any media type within the Facilis TerraBlock Shared

More information

Getting Started with DASYLab and MCC DAQ Hardware

Getting Started with DASYLab and MCC DAQ Hardware Getting Started with DASYLab and MCC DAQ Hardware This application note describes how to install and use DASYLab Version 10 with MCC data acquisition hardware. There are various exercises which detail

More information

OCTVQE Zaptel Echo Canceller (PRELIMINARY)

OCTVQE Zaptel Echo Canceller (PRELIMINARY) OCTVQE - Zaptel Echo Canceller User s Guide (Preliminary) OCTVQE Zaptel Echo Canceller (PRELIMINARY) User s Guide Revision 1.9 OctWare Inc. www.octware.net 4101, Molson St., Suite 300 Montreal Quebec H1Y

More information

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND OleumTechTM TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND MUST BE FAMILIAR WITH LEVEL 1 TRAINING MATERIALS BEFORE MOVING FORWARD Doc ID# 80-6010-001b TABLE OF CONTENTS 1. WHAT IS NEW WRITE IMPORT

More information

NetXplorer. Installation Guide. Centralized NetEnforcer Management Software P/N D R3

NetXplorer. Installation Guide. Centralized NetEnforcer Management Software P/N D R3 NetXplorer Centralized NetEnforcer Management Software Installation Guide P/N D357006 R3 Important Notice Important Notice Allot Communications Ltd. ("Allot") is not a party to the purchase agreement

More information

Addendum to Verbatim Gateway Owner's Manual. Gateway Ethernet Module Setup. Version 5.0

Addendum to Verbatim Gateway Owner's Manual. Gateway Ethernet Module Setup. Version 5.0 Addendum to Verbatim Gateway Owner's Manual Gateway Ethernet Module Setup Version 5.0 Revision History Rev # Description Author/Editor Date 3 Draft. Re-write of 2.0 Davey Hudson 4/10/2015 4 Draft. Re-write

More information

PCIe 10G SFP+ Network Controller Card

PCIe 10G SFP+ Network Controller Card PCIe 10G SFP+ Network Controller Card User Manual DN-10161 DN-10162 Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2 Features... 3 1.3 Requirements... 4 1.4 Package Contents...

More information

EAN-Startup Guide 1500-OEM

EAN-Startup Guide 1500-OEM EAN-Startup Guide 1500-OEM PN: EAN-Startup-Guide-1500-OEM 4/12/2018 SightLine Applications, Inc. Contact: Web: sightlineapplications.com Sales: sales@sightlineapplications.com Support: support@sightlineapplications.com

More information

GXLink MultiChannel Wave Inserter Model SP-631

GXLink MultiChannel Wave Inserter Model SP-631 800173-0A Digital High Speed GXLink MultiChannel Wave Inserter Model SP-631 User Manual Copyright 2009 It is prohibited to copy, reproduce or distribute this information in whole or in part without the

More information

SR3_Analog_32. User s Manual

SR3_Analog_32. User s Manual SR3_Analog_32 User s Manual by with the collaboration of March 2nd 2012 1040, avenue Belvédère, suite 215 Québec (Québec) G1S 3G3 Canada Tél.: (418) 686-0993 Fax: (418) 686-2043 1 INTRODUCTION 4 2 TECHNICAL

More information

Addendum to Verbatim Gateway Owner's Manual. Verbatim Gateway EtherNet Module Setup. Version 4.0

Addendum to Verbatim Gateway Owner's Manual. Verbatim Gateway EtherNet Module Setup. Version 4.0 Addendum to Verbatim Gateway Owner's Manual Verbatim Gateway EtherNet Module Setup Version 4.0 Revision History Rev # Description Author/Editor Date 3 Draft. Re-write of 2.0 Davey Hudson 4/10/2015 4 Draft.

More information

SIOS Protection Suite for Linux v Postfix Recovery Kit Administration Guide

SIOS Protection Suite for Linux v Postfix Recovery Kit Administration Guide SIOS Protection Suite for Linux v8.3.1 Postfix Recovery Kit Administration Guide September 2014 This document and the information herein is the property of SIOS Technology Corp. (previously known as SteelEye

More information

DATA ACQUISITION Hints and Tips

DATA ACQUISITION Hints and Tips How to use the SquirrelView software with the SQ2010/SQ2020/SQ2040 Data Loggers. SquirrelView Help Page 2 Connecting Your Squirrel Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data

More information

Grayhill 3Dxx Display Products. Setup and Usage with CoDeSys Development Software

Grayhill 3Dxx Display Products. Setup and Usage with CoDeSys Development Software Grayhill 3Dxx Display Products Setup and Usage with CoDeSys Development Software Revision History Revision Date Description A 09/14/2016 Original Release B 05/02/2017 Added support for Model 3D70 (Seven

More information

Modbus TCP for the Dynaview III. Porcine Associates 244 O'Connor Street Menlo Park, CA

Modbus TCP for the Dynaview III. Porcine Associates 244 O'Connor Street Menlo Park, CA Modbus TCP for the Dynaview III Porcine Associates 244 O'Connor Street Menlo Park, CA 94025 650-326-2669 www.dynaviewinc.com Table of Contents Modbus TCP for the Dynaview III... 1 1 Overview... 1 2 Installation...

More information

FreeWave Technologies Tool Suite Version 2.6.0

FreeWave Technologies Tool Suite Version 2.6.0 FreeWave Technologies Tool Suite Version 2.6.0 FreeWave Technologies, Inc. 1880 South Flatiron Court Boulder, CO 80301 (303) 444-3862 (303) 786-9948 Fax www.freewave.com Table of Contents FreeWave Tool

More information

Smart3G pn5732p Ethernet PLC. User Guide

Smart3G pn5732p Ethernet PLC. User Guide Smart3G pn5732p Ethernet PLC User Guide (Document Revision 1.4) (Updated: April 04, 2016) 2016 Vital Systems Inc Phoenix, AZ USA For more information please visit the product web page: www.vitalsystem.com/smart3g

More information

EMS Installation. Workstation Requirements CHAPTER. EMS Lite (Windows 95/98) EMS NT (Windows NT 4.0)

EMS Installation. Workstation Requirements CHAPTER. EMS Lite (Windows 95/98) EMS NT (Windows NT 4.0) CHAPTER 2 EMS Installation This chapter provides instructions for installing the Element Management System (EMS) software on a user workstation. Workstation Requirements The following sections list the

More information

WRTU Client User Manual. Date: 29 May, 2014 Document Revision: 1.05

WRTU Client User Manual. Date: 29 May, 2014 Document Revision: 1.05 WRTU Client User Manual Date: 29 May, 2014 Document Revision: 1.05 2014 by BiPOM Electronics, Inc. All rights reserved. WRTU Client User Manual. No part of this work may be reproduced in any manner without

More information

based on a previously created custom model an entirely new model

based on a previously created custom model an entirely new model Chapter 11: Custom Library Com'X 510 User Manual Custom Models The Com'X 510 supports the use of custom models. A custom model is any model other than a Built-in model from Schneider Electric. To use a

More information

AVT Vimba. AVT Vimba User Guide for Linux Jun-25 V1.2. Allied Vision Technologies GmbH Taschenweg 2a D Stadtroda / Germany

AVT Vimba. AVT Vimba User Guide for Linux Jun-25 V1.2. Allied Vision Technologies GmbH Taschenweg 2a D Stadtroda / Germany AVT Vimba AVT Vimba User Guide for Linux V1.2 2013-Jun-25 Allied Vision Technologies GmbH Taschenweg 2a D-07646 Stadtroda / Germany Contents Contents 1 Contacting Allied Vision Technologies 4 2 Introduction

More information

ESE 150 Lab 08: Machine Level Language

ESE 150 Lab 08: Machine Level Language LAB 08 In this lab we will gain an understanding of the instruction- level implementation of computation on a microprocessor by: 1. Using Arduino to perform the Fourier Transform on sampled data in the

More information

SST Configure Software OPERATION MANUAL

SST Configure Software OPERATION MANUAL SST Configure Software OPERATION MANUAL Trilithic Company Profile Trilithic is a privately held manufacturer founded in 1986 as an engineering and assembly company that built and designed customer-directed

More information

Quick Installation Guide for RHV/Ovirt

Quick Installation Guide for RHV/Ovirt Quick Installation Guide for RHV/Ovirt 2017 Chengdu Vinchin Technology Co. Ltd. All rights reserved. CONTENTS 1. Create New Virtual Machine...2 2. Install Backup Server ( as master)...5 3. Install Backup

More information

PCIe 10G 5-Speed. Multi-Gigabit Network Card

PCIe 10G 5-Speed. Multi-Gigabit Network Card PCIe 10G 5-Speed Multi-Gigabit Network Card User Manual Ver. 2.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction...

More information

Real Time Station Quick Start Guide

Real Time Station Quick Start Guide Real Time Station Quick Start Guide February 2015 IADS Version 8.1.2 SYMVIONICS Document SSD-IADS-016 1996-2015 SYMVIONICS, Inc. All rights reserved. Table of Contents 1. Introduction...4 1.1. Licensing...4

More information

Intellicus Cluster and Load Balancing- Linux. Version: 18.1

Intellicus Cluster and Load Balancing- Linux. Version: 18.1 Intellicus Cluster and Load Balancing- Linux Version: 18.1 1 Copyright 2018 Intellicus Technologies This document and its content is copyrighted material of Intellicus Technologies. The content may not

More information

Honeywell HC-900 with Acromag 967EN Modbus/TCP Module as Remote I/O

Honeywell HC-900 with Acromag 967EN Modbus/TCP Module as Remote I/O Acromag, Incorporated 30765 S Wixom Rd, PO Box 437, Wixom, MI 48393-7037 USA Tel: 248-295-0880 Fax: 248-624-9234 www.acromag.com Honeywell HC-900 with Acromag 967EN Modbus/TCP Module as Remote I/O Contents:

More information

EAN-Network Configuration

EAN-Network Configuration EAN-Network Configuration PN: EAN-Network-Configuration 1/25/2018 SightLine Applications, Inc. Contact: Web: sightlineapplications.com Sales: sales@sightlineapplications.com Support: support@sightlineapplications.com

More information

PDS Presentation Designer Quick Installation Guide

PDS Presentation Designer Quick Installation Guide In t r o d u c t i o n Overview PDS Presentation Designer is a handy tool that gives you the freedom and flexibility to design your presentation with a wide variety of media and messages. You can add,

More information

PROTEOMIC COMMAND LINE SOLUTION. Linux User Guide December, B i. Bioinformatics Solutions Inc.

PROTEOMIC COMMAND LINE SOLUTION. Linux User Guide December, B i. Bioinformatics Solutions Inc. >_ PROTEOMIC COMMAND LINE SOLUTION Linux User Guide December, 2015 B i Bioinformatics Solutions Inc. www.bioinfor.com 1. Introduction Liquid chromatography-tandem mass spectrometry (LC-MS/MS) based proteomics

More information

C Dr.-Ing. Abdalkarim Awad Informatik 7 Rechnernetze und Kommunikationssysteme

C Dr.-Ing. Abdalkarim Awad Informatik 7 Rechnernetze und Kommunikationssysteme C37.118 13.1.2016 Informatik 7 Rechnernetze und Kommunikationssysteme Measures Voltage, Current, phase PMU1 IEEE C37.118 WAN PDC Historian Phasor Data Concentrator HMI App1 PMU2 APn Bay1 Bayn LAN e.g.,

More information

5-Speed NBASE-T Network. Controller Card

5-Speed NBASE-T Network. Controller Card 5-Speed NBASE-T Network Controller Card User Manual Ver. 1.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction...

More information

For more information Contact with details of the application.

For more information Contact with details of the application. Eaton Corporation Telecommunications Power Solutions Email: dc.info@eaton.com www.eaton.com/telecompower Application Note AN0107 SC200 Modbus Server Last updated 20 January 2017 Applicable products SC200

More information

Queue Pro Queue Management System Version 4.4

Queue Pro Queue Management System Version 4.4 Queue Pro Queue Management System Version 4.4 Introduction: Queue Pro is the software that manages the queue in any customer interaction point smartly. The process starts with a customer who just pops

More information

Getting Started with PetaLinux SDK

Getting Started with PetaLinux SDK Getting Started with PetaLinux SDK November 26, 2009 Table of Contents Table of Contents...2 About This Guide...3 Related PetaLinux Documents...3 Getting Started...3 Prerequisites...3 Installation...4

More information

User Guide SS4-A HART

User Guide SS4-A HART User Guide SS4-A HART Page 1 of 14 Revision History Author Revision Date Comments T. Lapp A April 19, 2013 Initial release Page 2 of 14 Table of Contents 1 Introduction... 4 2 4-20 ma of SS4... 4 3 Supported

More information

Board Update Portal based on Nios II Processor with EPCQ (Arria 10 GX FPGA Development Kit)

Board Update Portal based on Nios II Processor with EPCQ (Arria 10 GX FPGA Development Kit) Board Update Portal based on Nios II Processor with EPCQ (Arria 10 GX FPGA Development Kit) Date: 1 December 2016 Revision:1.0 2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, HARDCOPY,

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION MS1000 2U SONAR PROCESSOR SMD P/N 901-10340000 Specifications subject to change without notice 901-10347902 Iss. 1.0 KONGSBERG MESOTECH LTD. 1598 Kebet Way, Port Coquitlam B.C. Canada

More information

LabVIEW programming II

LabVIEW programming II FYS3240 PC-based instrumentation and microcontrollers LabVIEW programming II Spring 2016 Lecture #3 Bekkeng 18.01.2016 Dataflow programming With a dataflow model, nodes on a block diagram are connected

More information

Retek Trade Management User Guide

Retek Trade Management User Guide Retek Trade Management 10.1 User Guide Retek Trade Management The software described in this documentation is furnished under a license agreement and may be used only in accordance with the terms of the

More information

GINESYS v DATABASE INSTALLATION GUIDE. GINESYS v DATABASE INSTALLATION GUIDE. January Aparajita Basu Roy TECHNICAL DOCUMENTER

GINESYS v DATABASE INSTALLATION GUIDE. GINESYS v DATABASE INSTALLATION GUIDE. January Aparajita Basu Roy TECHNICAL DOCUMENTER GINESYS v 11.100.0 DATABASE INSTALLATION GUIDE January 2016 Aparajita Basu Roy TECHNICAL DOCUMENTER 1 Table of Contents Introduction... 3 Minimum system requirement for using GINESYS... 3 Checks to be

More information

Parallels Virtuozzo Containers 4.6 for Windows

Parallels Virtuozzo Containers 4.6 for Windows Parallels Virtuozzo Containers 4.6 for Windows Upgrade Guide Copyright 1999-2010 Parallels Holdings, Ltd. and its affiliates. All rights reserved. Parallels International GmbH Vordergasse 49 CH8200 Schaffhausen

More information

Deployment Guide. 3.1 For Windows For Linux Docker image Windows Installation Installation...

Deployment Guide. 3.1 For Windows For Linux Docker image Windows Installation Installation... TABLE OF CONTENTS 1 About Guide...1 2 System Requirements...2 3 Package...3 3.1 For Windows... 3 3.2 For Linux... 3 3.3 Docker image... 4 4 Windows Installation...5 4.1 Installation... 5 4.1.1 Install

More information

A new D GHz CPU main board [REV: B01 or newer]. See Figure 1 New D GHz Main board (Rev: B01).

A new D GHz CPU main board [REV: B01 or newer]. See Figure 1 New D GHz Main board (Rev: B01). GE Digital Energy D400 CPU Migration Instructions TN00062 V1.00 R0 Technical Note This document: Provides the steps required to migrate existing firmware and configuration files to a 1.6 GHz D400. Applies

More information

Power IQ HyperV Quick Setup Guide

Power IQ HyperV Quick Setup Guide Power IQ HyperV Quick Setup Guide Thank you for your purchase of Sunbird's Power IQ. This Quick Setup Guide explains how to install and configure the Power IQ with Hyper-V. For additional information on

More information

Cisco Prime Network Registrar IPAM MySQL Database Replication Guide

Cisco Prime Network Registrar IPAM MySQL Database Replication Guide Cisco Prime Network Registrar IPAM 8.1.3 MySQL Database Replication Guide Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000

More information

SMG-1100/6100 User s Manual

SMG-1100/6100 User s Manual User s Manual First Edition, January 2011 www.moxa.com/product 2011 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. User s Manual The software described in this manual is

More information

HPE ComputeSensor. User Guide. Software Version: 3.02 Windows and Linux operating systems. Document Release Date: August 2017

HPE ComputeSensor. User Guide. Software Version: 3.02 Windows and Linux operating systems. Document Release Date: August 2017 HPE ComputeSensor Software Version: 3.02 Windows and Linux operating systems User Guide Document Release Date: August 2017 Software Release Date: August 2017 Legal Notices Warranty The only warranties

More information

Technical Guide Network Video Management System Tips and Troubleshooting

Technical Guide Network Video Management System Tips and Troubleshooting Technical Guide Network Video Management System Tips and Troubleshooting Network Video Management System October 27, 2017 NVMSTG010 Revision 1.0.0 CONTENTS 1. Overview... 3 1.1. About This Document...

More information

Real-time Cyber-Physical Co-simulation of Power Grids. Vahid Jalili-Marandi, Ph.D., OPAL-RT Technologies, Montreal, Canada April 2018

Real-time Cyber-Physical Co-simulation of Power Grids. Vahid Jalili-Marandi, Ph.D., OPAL-RT Technologies, Montreal, Canada April 2018 Real-time Cyber-Physical Co-simulation of Power Grids Vahid Jalili-Marandi, Ph.D., OPAL-RT Technologies, Montreal, Canada April 2018 Overview About OPAL-RT Technologies Real-time simulation (RTS) concepts

More information

AFP Digital

AFP Digital Installation Guide AFP Digital Installation Guide Page 2 Contents Overview...... 3 System Requirements... 5 Installing the EVA Hardware Driver... 6 AFP Digital Installation... 14 Installing AFP Digital

More information

Nimsoft options for routing messages (QoS/Alarms) between hubs

Nimsoft options for routing messages (QoS/Alarms) between hubs Nimsoft options for routing messages (QoS/Alarms) between hubs Document updated 10/28/2011 This document covers the following options: A. attach and get queues B. post queues C. nas replication The table

More information

Honeywell Trendview Recorder & Acromag 967EN Modbus/TCP Module as Remote I/O

Honeywell Trendview Recorder & Acromag 967EN Modbus/TCP Module as Remote I/O Acromag, Incorporated 30765 S Wixom Rd, PO Box 437, Wixom, MI 48393-7037 USA Tel: 248-295-0880 Fax: 248-624-9234 www.acromag.com Honeywell Trendview Recorder & Acromag 967EN Modbus/TCP Module as Remote

More information

Appliance Guide. Version 1.0

Appliance Guide. Version 1.0 Appliance Guide Version 1.0 Contents Contents 1 Revision history 2 Getting Started 3 Getting to Know the R7-3000/5000/5000x 5 Getting to Know the R7-1000 6 Setting Up the Appliance 7 Logging in to the

More information

WLM1200-RMTS User s Guide

WLM1200-RMTS User s Guide WLM1200-RMTS User s Guide Copyright 2011, Juniper Networks, Inc. 1 WLM1200-RMTS User Guide Contents WLM1200-RMTS Publication Suite........................................ 2 WLM1200-RMTS Hardware Description....................................

More information

PCIe Dual Port Gigabit Server. Adapter

PCIe Dual Port Gigabit Server. Adapter PCIe Dual Port Gigabit Server Adapter User Manual Ver. 2.01 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction...

More information

NVIDIA Professional Application Center

NVIDIA Professional Application Center NVIDIA Professional Application Center Network Licensing Guide 5 May 2017 Document version 2.0 Copyright Information 2017 NVIDIA Corporation. All rights reserved. This document is protected under copyright

More information

Beckhoff PlugIn. August V

Beckhoff PlugIn. August V Beckhoff PlugIn August 2015 - V01.05.00 Important and general information Table of contents 1 Important and general information... 4 1.1 Important information... 4 1.1.1 Safety and Warning instructions...

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION MS1000 2U STANDARD PROCESSOR P/N 901-10320000 Specifications subject to change without notice 901-10327902 Iss. 1.0 KONGSBERG MESOTECH LTD. 1598 Kebet Way, Port Coquitlam B.C. Canada

More information

Programming Studio #1 ECE 190

Programming Studio #1 ECE 190 Programming Studio #1 ECE 190 Programming Studio #1 Announcements In Studio Assignment Introduction to Linux Command-Line Operations Recitation Floating Point Representation Binary & Hexadecimal 2 s Complement

More information

APPLICATION NOTES. Advanced Graphical Interface - AGI Internal PLC (CODESYS V3) SHENDONG

APPLICATION NOTES. Advanced Graphical Interface - AGI Internal PLC (CODESYS V3) SHENDONG APPLICATION NOTES Advanced Graphical Interface - AGI Internal PLC (CODESYS V3) SHENDONG CODESYS V3 logic running on AGI 300/400 series product Support of Modbus/TCP and RTU communication Use of remote

More information

Installing Connector on Linux

Installing Connector on Linux CHAPTER 3 Revised: July 15, 2010 Overview This chapter provides a step-by-step guide to installing the Linux Connector on x86 and x86-64 servers running either Red Hat Enterprise Linux version 5 or Cent

More information

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK 1 USING THE XPERT2 / 9210B ON A TCP/IP NETWORK Prepared by: R&D January, 2009 Updated September 26, 2013 Sutron Corporation 22400 Davis Drive Sterling, Virginia 20164 TEL: (703) 406-2800 FAX: (703) 406-2801

More information

Operating guide. OPC server for ECL Comfort 310. Table of Contents

Operating guide. OPC server for ECL Comfort 310. Table of Contents Operating guide OPC server for ECL Comfort 310 Table of Contents 1. Introduction to Danfoss ECL OPC Server... 2 2. Configuring databases... 6 3. Exporting configuration data... 7 4. Importing data from

More information

Upgrading to Parallels Virtuozzo Containers 4.0 for Windows. Contents. About This Document

Upgrading to Parallels Virtuozzo Containers 4.0 for Windows. Contents. About This Document Upgrading to Parallels Virtuozzo Containers 4.0 for Windows About This Document This document familiarizes you with the way to upgrade the following versions of the Virtuozzo for Windows software to Parallels

More information

Upgrade Instructions Software Pursuits, Inc.

Upgrade Instructions Software Pursuits, Inc. Upgrade Instructions 2010 Table of Contents Introduction... 2 System Requirements for SureSync 6... 2 Upgrading to a Newer Version of SureSync 6... 3 Important Notes for Upgrading from Previous Versions...

More information