Quick Start Guide v1.0

Size: px
Start display at page:

Download "Quick Start Guide v1.0"

Transcription

1 ValVue Suite Valve Interface Portal ValVue ESD ValVue ESD Standalone ValVue ESD PRM Plug-In Quick Start Guide v

2 2

3 Preface This booklet is a guide for selecting, installing and executing the ValVue ESD application as well as verifying that the destination computer satisfies the installation requirements. For support and questions about this product, contact your nearest Masoneilan representative (locations can be found at or your technical support inquiries to svi2esdsupport@masoneilan.com Thank you for choosing Masoneilan s safety solutions. Sandro Esposito Product Marketing Manager Smarts Products Dresser Masoneilan 1

4 Contents Introduction...3 Installation Requirements...4 Hardware...4 Software...4 Installing the Applications...5 Installing ValVue ESD Standalone...5 Installing the PRM Related Applications...7 Installing Central ValVue ESD...7 Installing PRM PLUG-IN ValVue ESD...10 PRM Setup Requirements...12 How to Associate Plug-in with Device...12 How to Associate the SVI II ESD Icon with the SVI II ESD Device...13 Launching the Applications...14 Launching ValVue ESD Standalone...14 Launching PRM Central ValVue ESD...15 Launching PRM PLUG-IN ValVue ESD...18 Startup of an SVI II ESD...18 Calibrating...18 Partial Stroke Test...19 Settings...19 Launching a PST...21 Viewing a PST and its Results...22 On-Line Help...23 PLUG-IN ValVue ESD Warnings...23 PRM Multi-Server...23 PRM PLUG-IN ValVue ESD Installation Folder...23 Appendix

5 Introduction The ValVue ESD family contains three applications, ValVue ESD, PRM Central ValVue ESD, PRM PLUG-IN ValVue ESD and ESDVue which is a common library. Standalone edition The standalone application connects directly to one or more devices through a HART modem or a MTL Multiplexer network. Yokogawa PRM PLUG-IN edition First, the application consists of the PRM Central ValVue ESD. It is the ValVue ESD service that monitors all registered Masoneilan, type 203 devices (SVI II ESD) known by the PRM server. It automatically retrieves and saves the Partial Stroke Tests (PST) results for all devices to the ValVue ESD central database. This functionality ensures the results in the database are logged no matter how the PST test is triggered (locally, remotely, schedule, handheld, analog, etc). It also provides for a snap-shot of the PST schedules and health of all SVI II ESD devices. PRM PLUG-IN ValVue ESD This is the ValVue ESD application that will launch as the PLUG-IN for Masoneilan s SVI II ESD device (type 203) from the PRM UI. It also provides for a snap-shot of the PST schedules and health of all SVI II ESD devices. ESDVue This is the user friendly dialog (or session) that is launched from ValVue ESD (PLUG-IN or standalone). It allows the user to access all HART features available from the device including status, diagnostics, configuration, calibration, etc. It also allows the user to access and graph historical data saved to the database for all devices contained in the database. 3

6 Installation Requirements Hardware Processor: PC with minimum 1 GHz Intel Pentium or compatible RAM: minimum 1gig Disk: Depends on product Product Application Component Database Component ValVue ESD 15M 30M minimum* 45M PRM Central 15M 30M minimum* 45M ValVue ESD PRM PLUG-IN ValVue ESD 15M N/A 15M *Assuming 100 devices, 1 PST/month for 5 years Total Installation Size Software OS: Windows XP SP2 Window Server 2003 with Service Pack 1 or Window Server 2003 R2 PRM: PRM R3.x Note: PRM is NOT required for standalone installations. 4

7 Installing the Applications Figure 1 shows the installation browser for ValVue ESD. The browser allows you to install each one of the applications that comprise the ValVue ESD family and to view documentation for the products and other helpful information. If you wish to connect your computer to a device directly through a HART modem or MTL Multiplexer, then install the standalone version. If you wish to integrate ValVue ESD with PRM and connect to devices using the PRM PLUG-IN, then install the PLUG-IN client on your computer. Integration with the PRM system also requires installation of the PRM Central ValVue ESD for each PRM server in the system. The following sections provide instructions for the installation of each one of the applications. Figure 1 ValVue ESD Installation Browser Installing ValVue ESD Standalone Click on Install Standalone Edition on the installation browser to begin installing ValVue ESD Standalone. The first dialog box where you will be asked to make a decision is for the installation folder shown in Figure 2. If you prefer not to use the default, click on Change to select a different one. That will bring up the file browser shown in Figure 3. You may select any path from the file browser or enter the path directly. If the specified folder does not exist, it will be created for you. There are no disadvantages for the location of this installation folder. 5

8 Figure 2 Choose Standalone Destination Location Figure 3 Choose Standalone Folder 6

9 Installing the PRM related applications To install the PRM related applications click on Yokogawa PRM Edition on the installation browser. This will show the PRM installation browser shown in Figure 4. Typically, PRM Central ValVue ESD will be used to monitor all devices while PLUG-IN ValVue ESD will be used to access the functionality of the device. Figure 4 PRM ValVue ESD Installation Browser Installing Central ValVue ESD This application should be installed on each PRM server in the control system, preferably the server machine. Click on Install Central Server on the PRM installation browser to begin installing Central ValVue ESD. The first dialog box where you will be asked to make a decision is for the installation folder shown in Figure 5. If you prefer not to use the default, click on Change to select a different one. That will bring up the file browser shown in Figure 6. You may select any path from the file browser or enter the path directly. If the specified folder does not exist, it will be created for you. There are no disadvantages for the location of this installation folder. 7

10 Figure 5 Choose Central Destination Location Figure 6 Choose Central Folder Next you will be asked where to install the central database as shown in Figure 7. Again, if you prefer not to use the default, click on Change which will bring up the file browser shown in Figure 8. You may select any path from the file browser or enter the path directly. If the specified folder does not exist, it will be created for you. You should make a note of this machine name and folder share name, ValVue ESD DATABASE because it will be needed when installing PRM PLUG-IN ValVue ESD. 8

11 The installer will also create a data source for the database. If the database already exists, the installer will update the tables if necessary. No existing data will be lost. Figure 7 Choose Database Destination Location Figure 8 Choose Database Folder 9

12 Installing PRM PLUG-IN ValVue ESD This application should be installed on every computer on which PRM Client is installed after Central ValVue ESD has been installed for the particular PRM server. This application does not require registration. Click on Install PLUG-IN Clien to begin installing PRM PLUG-IN ValVue ESD. The first dialog box where you will be asked to make a decision is for the installation folder shown in Figure 7. If you prefer not to use the default, click on Change to select a different one. Figure 9 Choose PLUG-IN Destination Location This will show the file browser shown in Figure 8. You may browse to the path or enter the path directly; regardless, the path must be the same for all PRM PLUG-IN ValVue ESD installations. Note that if you assign the installation to a different path from the previous installs, including drive, PRM PLUG-IN ValVue ESD will no longer launch from the previous computers unless the full path is accessible from the previous computers. 10

13 Figure 10 Choose PLUG-IN Folder Next you will be asked to locate the central database that was installed with Central ValVue ESD. In the dialog box if the location shown is not correct as is shown in Figure 11, click on Change and locate the location of the database using the file browser or enter it directly. Figure 12 shows the file browser. The name of the shared folder is ValVue ESD DATABASE. Figure 11 Choose Central Database Location 11

14 Figure 12 Choose Shared Database Folder The installer will automatically register the PRM PLUG-IN ValVue ESD within PRM. PRM setup requirements In order to finalize the integration of ValVue ESD with PRM, a few manual steps must be performed as outlined in this section. How to associate plug-in with device Though the installer for the PRM PLUG-IN ValVue ESD will automatically register the plug-in with PRM, the SVI II ESD devices must be associated with this plug-in. This is accomplished manually. To associate the plug-in, start the PRM client from any machine on which PLUG-In ValVue ESD was installed and perform the following for each SVI II ESD device in the PRM system: Double-click a SVI II ESD device (identified by Vendor=Masoneilan, Model=Device_203) in the PRM user interface 12

15 Select Plug-In from the toolbar that appears on the next screen Right click in the Plug-In Name window and select Add from the resulting popup menu Select PRM PLUG-IN ValVue ESD from the list of plug-in names that appear How to associate the SVI II ESD icon with the SVI II ESD device The Masoneilan SVI II ESD icon looks like that shown in Figure 13. If this icon does not appear in your PRM tree view, it must be assigned manually. Figure 13 SVI2ESD_ICON To assign the icon, start PRM client from any machine on which PLUG- IN ValVue ESD was installed and perform the following once: Register the device icon - From the main menu select Register/Master Data/Register Device Icon - From the Device Icon List screen select Add - Enter the following parameters in the form: Location of image file: ValVue ESD install directory/ Icons/SVI II ESD.bmp Icon ID: SVI II ESD Description: Masoneilan SVI II ESD 13

16 Assign the registered icon with the device - From the main menu select Register/Master Data/Register Assign Icon - From the Assignment of Device Icons screen select Add Enter the following parameters in the form: - Vendor: Masoneilan - Model: Device_203 - Sub Model: blank - Icon: select the icon you registered You should now see the icon appear for all Masoneilan, Device_203 devices in the display. Launching the Applications Launching ValVue ESD Standalone To launch ValVue ESD Standalone simply double-click the ValVue ESD icon installed on the desktop. The application requires separate registration on each computer on which it is installed, but comes with a free, fully functional 60-day trial period. Until the application is registered, the dialog box shown in Figure 14 will appear when the application is started. Enter the information to register. Just hit enter to run unregistered. A dialog box will appear to inform you how many days are left on the trial period as shown in Figure 15. At the end of the trial period the application will no longer run without registering. 14

17 Figure 14 Standalone Registration Dialog Figure 15 Standalone Trial Period Information ValVue ESD Standalone comes configured for a HART modem connected to COM1. If your configuration differs from this, you will need to change the ValVue ESD options. The connection options can be changed by selecting Tools/Set Options from the main menu. Please note that it may take several seconds for ValVue ESD to resolve that there is no device present if this is the incorrect configuration because of the wait time and retries that ValVue ESD employs to ensure reliable HART communication. If ValVue ESD connects with a device, it will include it in the device list. Selecting this device from the list or double-clicking on it will launch ESDVue and allow you to view and initiate all the features provided by the SVI II ESD and ValVue ESD. 15

18 Launching PRM Central ValVue ESD PRM Central ValVue ESD is intended to run as a service on the PRM server machine, but it can be launched directly by double-clicking the PRM Central ValVue ESD icon that was installed on the desktop. (The application will prevent more than one instance from running on the computer.) The service will start automatically after the computer restarts. PRM Central ValVue ESD requires registration to run, but comes with a free, fully functional 60-day trial period. Until the application is registered, the dialog box shown in Figure 16 will appear when the application is started whether as service or from the desktop. Enter the information to register or just hit enter to run unregistered. A dialog box will appear to inform you how many days are left on the trial period as shown in Figure 17. At the end of the trial period the application will no longer run without registering. Figure 16 Central Registration Dialog 16

19 Figure 17 Central Trial Period Information When launched as a service, its icon, shown in Figure 18, will appear in the system tray. Double-click on the icon to see the ValVue ESD user interface. Note, that when there is no activity in the user interface for some period, the Central ValVue ESD will return to the tray. Also, if you exit the application launched as a service, it will restart automatically. To disable this feature just stop the service called XMnCloSvr using the Windows Services Management tool. Figure 18 PRM Central ValVue ESD Service Icon Using the PIA API, the application will list all devices known to the PRM server to which it is connected. By default it searches the path: CLASS:PLANT\HART\MASONEILAN. A separate license is required to monitor devices. The application comes with a free license to monitor 5 devices for a 60-day trial period. At the end of the trial period PRM Central ValVue ESD will no longer monitor the devices unless licensed. Regardless of the license, the application will support all Masoneilan Device Type 203 devices that it finds in the device list; however, those devices not covered by the license will show an icon to indicate that the device is not monitored. View the on-line help for more information about the icons that can show in the device list. Launch ESDVue to access all the features available from the device and run diagnostics for a selected valve. To do so, simply double-click on the desired valve in the valve list or select it and click on the Select button. 17

20 Launching PRM PLUG-IN ValVue ESD PRM PLUG-IN ValVue ESD is launched from the PRM client user interface once it has been registered in the PRM and associated with a specific device as explained above. The PRM Central ValVue ESD associated with the PRM server must be running. Executing the plug-in, launches PRM PLUG-IN ValVue ESD. This automatically launches ESDVue for the selected device, provided that PRM Central ValVue ESD has been licensed for that device. The licensing restrictions described above for PRM Central ValVue ESD also apply to PRM PLUG-IN ValVue ESD. After ESDVue is exited, ESDVue can be launched for another licensed device in the device list. Startup of an SVI II ESD Calibrating If the unit was pre-installed on an actuator, it is not necessary to perform any calibrations. Proceed to the section PST to configure the device to conduct a partial stroke test. Otherwise proceed as follows: All precautions per the Quick Start Guide QS5000 must be adhered to. Per the Quick Start Guide QS5000, install the SVI II ESD on the actuator and apply electrical and air supply. Launch an ESDVue session with the connected device and go to the calibrate page. Set the mode to SETUP using the MODE button located on the bottom of the user interface. 5. Click on TOOLS -> Find Valve Stops. This procedure will fill and exhaust the actuator chamber and measure the mechanical travel. This procedure will take approximately 1 minute. 18

21 6. Click on TOOLS -> AUTOTUNE. This procedure will determine the tuning parameters that will be utilized to move the valve during a PST test. The values are also utilized when the SVI II ESD positions the ESD Valve in the MANUAL mode. This procedure will take approximately 3-5 minutes and may take as much as 8 minutes. If the procedure fails, click on TOOLS -> RESET TO DEFAULT to utilize the default values. 7. Set the mode back to NORMAL. Partial Stroke Test Settings 1. The settings can be modified in the NORMAL and SETUP Mode. 2. The PST settings are described in the On-Line Help. For your convenience here s a summary of the parameters: PST Travel The allowed valve movement from full Open position in percentage of travel. A typical value is 20%. Maximum allowed is 30%. The greater the travel range, the more accurate the results from the PST Test. Minimum Pressure The allowed reduction in pressure in the actuator to achieve the desired PST Travel. This value depends on the spring range and the valve/actuator hysterisis. To set this value, first, run an Extended Actuator signature from the DIAGNOSTICS PAGE. Then, locate on the Y-Axis of the signature, the X-Axis pressure value for the desired Travel target. For example, if the PST Travel is 30%, what is the pressure value to reach 70% travel. The Y-value selected must be on the upper curve of the graph. 19

22 Maximum Time The allowed amount of time in seconds before the PST test aborts. This value can be determined as follows: - Maximum Time = (Travel Range * 2 * PST Speed ) + Dwell Time + 5 seconds. PST Speed The valve Travel speed in % Travel per second. Dwell Time The amount of time in seconds between the down ramp and the up ramp of valve stroke. Friction Low Limit The alarm threshold for low friction. This alarm is set if the analyzed friction from the PST test is less than this value. Engineering units of pressure (PSI, kpa or BAR). Friction High Limit The alarm threshold for high friction. This alarm is set if the analyzed friction from the PST test is more than this value. Engineering units of pressure (PSI, kpa or BAR). Breakout Limit The alarm threshold for valve breakout force (force to initiate valve movement). This alarm is set if the analyzed friction from the PST test is more than this value. Engineering units of pressure (PSI, kpa or BAR). Droop Limit The alarm threshold for air supply inlet droop. This alarm is set if the analyzed Air Supply Droop from the PST test is more than this value, indicating a possible clogged up air filter in the air set or lack of volume feeding the SVI II ESD. Engineering units of pressure (PSI, kpa or BAR). 20

23 Freeze DO (Digital Output) Enable for the DO2 (SW#2) to not change state during a PST. Freeze AO (Analog Output) Enable for the built-in positioner transmitter to not update its output value during a PST. Enable Schedule Enable to allow execution of the Automated PST Schedules. Breakout Upper Spring Range PST Range Valve/Actuator Friction/2 Minimum Allowed Actuator Pressure During PST Launching a PST IMPORTANT: A PST CAN ONLY BE LAUNCHED WITH THE SVI II ESD DEVICE IN NORMAL MODE The SVI II ESD offers several methods to launch a PST: 1. Using ValVue ESD (PST Page) 21

24 2. Using the local display/pushbutton 3. Using a HART handheld device with the SVI II ESD Device Descriptor (DD) Using any HART host capable of DD services (such as SDC-625) and loaded with the SVI II ESD Device Descriptor Using the Automatic Scheduler (Calendar based, built-in the SVI II ESD) By setting the loop current to 16.4mA (77.5%). Available with ASD models and A/DSD models. Two PST s can be stored in the non-volatile memory of the SVI II ESD. This allows for ValVue ESD to synchronize its database with the data in the field. When launching the PST from ValVue ESD, the information will be automatically saved in the database at the end of the PST. If the PST is executed with the other methods described, the PST signature will remain in the non-volatile memory with a Flag indicating that ValVue ESD has not yet synchronized its database with the latest signature. The Flag will be lowered as soon as ValVue ESD connects to the device, or until the Central Lookout Service (PRM or Multiplexer operations only) scans the device. The signatures in the device are First In First Out (FIFO). Viewing a PST and its results To view a PST: 1. From ValVue ESD, right-click on the device and select View Latest PST or Historical View. From the Historical View, double-click on the X which indicates a dataset. 2. From ESDVue, go to the PST page and select the Diagnostic To Load, then Click on Load Diagn. 22

25 On-Line Help For more information about getting started, click on the Help button located in the lower right corner of the ValVue ESD main screen. In fact help is available for every ValVue ESD and ESDVue dialog by simply clicking on the Help button or Help menu selection, depending on the dialog. The F1 key also provides help for most active dialogs. PLUG-IN ValVue ESD warnings PRM Multi-Server Please note that because of the connection with the database and Central ValVue ESD, the Multi-Server switching feature, available on the PRM client, is not allowed. PRM PLUG-IN ValVue ESD installation folder As mentioned in installation instructions, the PLUG-IN ValVue ESD application must be installed to the same drive and folder on all machines which connect to the same PRM server. 23

26 Appendix Database storage requirements where the diagnostics use the typical setup parameters: Basic database Basic storage per device Partial Stoke Test Extended Signature diagnostics Step diagnostics 350K bytes 20K bytes 1.2K bytes 2.7K bytes 4.2K bytes For comments, feature request or any inquiries about ValVue ESD, send an to P/N: Rev. A 24

27 25

28 26 PN Rev. A

SVI II ESD. SIL3 Partial Stroke Test Device October 2007 BW5000-ESD. The only SIL3 Smart ESD device that is live during and after a shutdown.

SVI II ESD. SIL3 Partial Stroke Test Device October 2007 BW5000-ESD. The only SIL3 Smart ESD device that is live during and after a shutdown. SVI II ESD SIL3 Partial Stroke Test Device October 2007 BW5000-ESD The only SIL3 Smart ESD device that is live during and after a shutdown. Patents Pending What is the SVI II ESD? The SVI II ESD is the

More information

II ESD. SIL3 Partial Stroke Test Device. The only SIL3 Smart ESD device that is live during and after a shutdown.

II ESD. SIL3 Partial Stroke Test Device. The only SIL3 Smart ESD device that is live during and after a shutdown. SVI II ESD SIL3 Partial Stroke Test Device The only SIL3 Smart ESD device that is live during and after a shutdown. W h a t i s t h e S V I I I E S D? The SVI II ESD is the latest technology in emergency

More information

SoftTools Suite 7.0. Flowserve Corporation

SoftTools Suite 7.0. Flowserve Corporation SoftTools Suite 7.0 Quick Start Guide for SoftTools 7.0 with support for the HART Communications Protocol on the Logix 1200/1200e, 3200IQ, and 500/500si Series Positioners Flowserve Corporation Flow Control

More information

PST Scheduler Engineering Guide with Metso positioner

PST Scheduler Engineering Guide with Metso positioner PST Scheduler Engineering Guide with Metso positioner 1/36 Copyright and Trademark Notices Trademark Acknowledgments All Right Reserved, Copyright 2011 Yokogawa Electric Corporation For Chapter 8 courtesy

More information

PST Scheduler Engineering Guide with SAMSON positioner

PST Scheduler Engineering Guide with SAMSON positioner Yokogawa Electric Corporation SBDB-110029 PST Scheduler Engineering Guide with SAMSON positioner 1/28 Copyright and Trademark Notices Trademark Acknowledgments All Right Reserved, Copyright 2011 Yokogawa

More information

PST Scheduler Engineering Guide with Flowserve positioner

PST Scheduler Engineering Guide with Flowserve positioner Yokogawa Electric Corporation SBDG-110003 PST Scheduler Engineering Guide with Flowserve positioner 1/28 Copyright and Trademark Notices Trademark Acknowledgments All Right Reserved, Copyright 2012 Yokogawa

More information

Installing ValveLink Software. ValveLink Solo ValveLink SNAP ON ValveLink DTM ValveLink PLUG IN for PRM. Installation Guide D102800X012

Installing ValveLink Software. ValveLink Solo ValveLink SNAP ON ValveLink DTM ValveLink PLUG IN for PRM. Installation Guide D102800X012 Installation Guide ValveLink Software Installing ValveLink Solo ValveLink SNAP ON ValveLink DTM ValveLink PLUG IN for PRM www.fisher.com This page intentionally left blank. Installation Guide Table of

More information

User s Manual. YVP Management Software ValveNavi. Manual Change No

User s Manual. YVP Management Software ValveNavi. Manual Change No User s Manual YVP Management Software ValveNavi Manual Change No. 12-028 Please use the attached sheets for the pages listed below in the following manuals. (5th) Page and Item Page 2-1 2.2 ValveNavi Specifications

More information

FIELDVUE Instrumentation

FIELDVUE Instrumentation Product Bulletin FIELDVUE Instrumentation Communicate with both HART and FOUNDATION Fieldbus FIELDVUE digital valve controllers Configure, calibrate, and diagnose FIELDVUE instruments from one location

More information

Installing and Setting Up the Snap-on EPC. Rev.1.10 (10 Oct 2013) PN EN

Installing and Setting Up the Snap-on EPC. Rev.1.10 (10 Oct 2013) PN EN Installing and Setting Up the Snap-on EPC Rev.1.10 (10 Oct 2013) PN 275-0800-EN Table of Contents 1. Introduction... 3 2. Minimum Requirements... 4 3. Installing the Snap-on EPC... 6 4. Licensing the Snap-on

More information

The following steps will allow you to install and quickly begin using DevCom2000:

The following steps will allow you to install and quickly begin using DevCom2000: QUICK START DevCom2000 uses Device Descriptions (DDs) to access data stored in the memory of the smart field device. These DDs are developed by the manufacturer for their products and, in turn, distributed

More information

USER INSTRUCTIONS. Flowserve ValveAnalysis. Installation and Operation. Experience In Motion. Diagnostic Software Module FCD VLENIM /06

USER INSTRUCTIONS. Flowserve ValveAnalysis. Installation and Operation. Experience In Motion. Diagnostic Software Module FCD VLENIM /06 USER INSTRUCTIONS Flowserve ValveAnalysis Diagnostic Software Module FCD VLENIM0113-01 1/06 Installation and Operation Experience In Motion 1 Introduction Flowserve s easy-to-use and informative ValveAnalysis

More information

QUICK START. DevCom2000 User Manual

QUICK START. DevCom2000 User Manual QUICK START DevCom2000 uses Device Descriptions (DDs) to access data stored in the memory of the smart field device. These DDs are developed by the manufacturer for their products and, in turn, distributed

More information

Installing and Setting Up the Snap-on EPC. Rev.1.6 (12 Apr 2012) PN EN

Installing and Setting Up the Snap-on EPC. Rev.1.6 (12 Apr 2012) PN EN Installing and Setting Up the Snap-on EPC Rev.1.6 (12 Apr 2012) PN 275-0800-EN Table of Contents 1. Introduction... 3 2. Minimum Requirements... 4 3. Installing the Snap-on EPC... 6 4. Licensing the Snap-on

More information

The following steps will allow you to install and quickly begin using DevCom:

The following steps will allow you to install and quickly begin using DevCom: QUICK START DevCom uses Device Descriptions (DDs) to access data stored in the memory of the smart field device. These DDs are developed by the manufacturer for their products and, in turn, distributed

More information

Safe & available...vigilant!

Safe & available...vigilant! Safe & available...vigilant! Why not have the best of both worlds? The vigilant approach delivers uptime and peace of mind. Operators now have an all-in-one interface to effectively handle both control

More information

AMS ValveLink Software Quick-Start Guide

AMS ValveLink Software Quick-Start Guide Quick-Start Guide Form 5745 September 2006 AMS ValveLink Software Quick-Start Guide D102813X012 www.fisher.com FIELDVUE, PlantWeb, ValveLink, and Fisher are marks owned by Fisher Controls International

More information

SPOT 5.3 BASIC Software

SPOT 5.3 BASIC Software SPOT 5.3 BASIC Software Imaging Software for Microscopy and Macro-Photography IF YOU ALSO PURCHASED SPOT ADVANCED SOFTWARE OR ANY SPOT ADVANCED SOFTWARE MODULE: This guide and the activation codes below

More information

9936A LogWare III. User s Guide. Revision

9936A LogWare III. User s Guide. Revision 9936A LogWare III User s Guide Revision 850701 Table of Contents 1 Introduction...1 1.1 Symbols Used... 1 1.2 Conventions... 1 1.3 What is LogWare?... 1 1.4 License Agreement... 2 1.5 Requirements...

More information

DBT-120 Bluetooth USB Adapter

DBT-120 Bluetooth USB Adapter DBT-120 Bluetooth USB Adapter Rev.2.1 (09/25/2002) 2 Contents Introduction... 5 Package Contents... 6 Installing Bluetooth Software... 6 Hardware Installation... 8 Introduction to Bluetooth Software...

More information

Masoneilan * ValVue * Software

Masoneilan * ValVue * Software Masoneilan * ValVue * Software Instruction Manual (Rev. F) BHGE Data Classification: Public About this Guide DISCLAIMER Copyright The information contained in this manual, in whole or part, shall not be

More information

Operating Instructions EB 8388 EN. Series 373x Positioners. EXPERT + Valve Diagnostics

Operating Instructions EB 8388 EN. Series 373x Positioners. EXPERT + Valve Diagnostics Series 373x Positioners EXPERT + Valve Diagnostics Fig. 1 Valve diagnostics with SAMSON TROVIS-VIEW Operator Interface, e.g. for Type 3730-3 Positioner Operating Instructions EB 8388 EN Firmware version

More information

The following steps will allow you to install and quickly begin using DevCom:

The following steps will allow you to install and quickly begin using DevCom: QUICK START DevCom uses Device Descriptions (DDs) to access data stored in the memory of the smart field device. These DDs are developed by the manufacturer for their products and, in turn, distributed

More information

Proximity Positioner. ICoT. Valve Monitoring and Control Products WESTLOCK

Proximity Positioner. ICoT. Valve Monitoring and Control Products WESTLOCK Proximity Positioner UNLIKE CONVENTIONAL POSITIONERS, THE ICOT POSITIONER FEEDS BACK VALVE POSITION WITHOUT THE NEED FOR LINKAGES OR LEVERS. Non-contact position feedback is accomplished through the use

More information

StreetWise Partner. Version 3.0. Naztec Operations Manual. April For. Published by:

StreetWise Partner. Version 3.0. Naztec Operations Manual. April For. Published by: Naztec Operations Manual For StreetWise Partner Version 3.0 April 2003 Published by: Naztec, Inc. 820 Park Two Drive Sugar Land, Texas 77478 Phone: (281) 240-7233 Fax: (281) 240-7238 Copyright 2003 Naztec,

More information

1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically.

1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically. 1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically. If setup does not launch, use Windows Explorer to navigate to the appropriate CD- ROM

More information

FX Tools Software Package - FX CommPro N2 User s Guide

FX Tools Software Package - FX CommPro N2 User s Guide User s Guide FX CommPro N2 Issue Date September 25, 2008 FX Tools Software Package - FX CommPro N2 User s Guide FX Tools Software Package FX CommPro N2... 3 Introduction...3 Installation... 4 Installing

More information

Device Management System [R 41]

Device Management System [R 41] No. SS2-IFO410-0001 (Edi. 1) Device Management System [R 41] What is InnovativeField Organizer? InnovativeField Organizer (hereinafter IFO) is a device management system for smart field devices that supports

More information

FieldMate Handheld Communicator Data Converter for FieldMate. User s MANUAL

FieldMate Handheld Communicator Data Converter for FieldMate. User s MANUAL FieldMate Handheld Communicator Data Converter for FieldMate Introduction User s MANUAL The FieldMate Handheld Communicator Data Converter for FieldMate ( Data Converter ) is a data-interfacing software

More information

GraffixPro Studio Getting Started Guide

GraffixPro Studio Getting Started Guide GraffixPro Studio Getting Started Guide The GraffixPro Studio Software is comprised of a set of linked applications: the Administrator, the Library, and the design software. This guide outlines the procedures

More information

Performance!Nxt Release

Performance!Nxt Release July 4, 2016 Performance!Nxt Release 12.7120 Flowserve is pleased to announce the latest release of Performance!Nxt, the industry s foremost Control Valve Sizing, Selection and Project Management Software.

More information

Powerline Network. Utility Program User Guide. for. Instant Network for Internet Access and More! 200Mbps PLC-ETHERNET BRIDGE

Powerline Network. Utility Program User Guide. for. Instant Network for Internet Access and More! 200Mbps PLC-ETHERNET BRIDGE Powerline Network Instant Network for Internet Access and More! Solution for SOHO, SMALL OFFICE AND HOME OFFICE Utility Program User Guide for 200Mbps PLC-ETHERNET BRIDGE 1 Index 1. Introduction...3 1.1.

More information

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology VVP10-H HART VALVE POSITIONER Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol Electronic Coil Technology Non-Contact Position Sensor (Hall Sensor) 4-20 ma NAMUR NE

More information

9936A LogWare III. User s Guide. Revision

9936A LogWare III. User s Guide. Revision 9936A LogWare III User s Guide Revision 680301 Table of Contents 1 Introduction... 1 1.1 Symbols Used...1 1.2 Conventions...1 1.3 What is LogWare?...1 1.4 License Agreement...2 1.5 Requirements...2 1.6

More information

Masoneilan. A LESSON ON Foundation Fieldbus DD s and DD METHODS

Masoneilan. A LESSON ON Foundation Fieldbus DD s and DD METHODS A LESSON ON Foundation Fieldbus DD s and DD METHODS BY SANDRO ESPOSITO 1. Introduction The Foundation Fieldbus protocol is one of the leaders in the industrial process control arena. Yet, it can provide

More information

UbiLive Home Edition 2.0 User Guide

UbiLive Home Edition 2.0 User Guide UbiLive Home Edition 2.0 User Guide 1 Table of contents 1. Product Overview... 3 1.1 Language Supports... 3 2. Installation... 3 2.1 System Requirements... 3 2.2 Installation Procedure... 3 2.3 Firewall

More information

Avigilon Control Center Server User Guide

Avigilon Control Center Server User Guide Avigilon Control Center Server User Guide Version 4.12 PDF-SERVER-E-Rev1 Copyright 2012 Avigilon. All rights reserved. The information presented is subject to change without notice. No copying, distribution,

More information

MYOB ODBC Direct. Installation Guide

MYOB ODBC Direct. Installation Guide MYOB ODBC Direct Installation Guide About MYOB ODBC Direct Copyright and Trademark Information MYOB ODBC Direct is an ODBC driver that makes your MYOB company file information accessible from other applications.

More information

USER MANUAL. Valve System Test Centre 1/26

USER MANUAL. Valve System Test Centre 1/26 USER MANUAL Valve System Test Centre 1/26 Table of contents 1 General... 3 1.1 Safety instructions... 3 2 Application... 4 3 Specifications... 5 3.1 Environment... 5 3.2 Terminals... 5 3.3 Dimensions and

More information

SolarPower Pro. User s Manual. Management Software for Solar Inverter

SolarPower Pro.  User s Manual. Management Software for Solar Inverter SolarPower Pro User s Manual Management Software for Solar Inverter Table of Contents 1. SolarPower Pro Overview... 2 1.1. Introduction... 2 1.2. Structure... 2 1.3. Features... 3 2. SolarPower Pro Install

More information

Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the software, please review the readme files,

More information

PS-4700/4800Series User ユーザーマニュアル Hardware Manual Manual

PS-4700/4800Series User ユーザーマニュアル Hardware Manual Manual PS-4700/4800Series シリーズ User ユーザーマニュアル GP-4000 Pro-face Manual Series Remote HMI Server Hardware Manual Manual (Atom N270/Core 2 Duo 2 Duo P8400 P8400 Pre-installed 搭載モデル Model) ) Preface Thank you for

More information

Multi-NVR Manager. Quick Start Configuration Usage

Multi-NVR Manager. Quick Start Configuration Usage Multi-NVR Manager Quick Start Configuration Usage 2014. All rights are reserved. No portion of this document may be reproduced without permission. All trademarks and brand names mentioned in this publication

More information

The Cingular Connection Manager

The Cingular Connection Manager Introduction Welcome to the world of wireless connectivity and thank you for choosing Cingular as your service provider. Within this User Guide, you will find the information that you need to connect to

More information

Avigilon Control Center Server User Guide

Avigilon Control Center Server User Guide Avigilon Control Center Server User Guide Version 5.0 PDF-SERVER5-A-Rev1 Copyright 2013 Avigilon. All rights reserved. The information presented is subject to change without notice. No copying, distribution,

More information

READ ME FIRST Windows 98/ME/2000

READ ME FIRST Windows 98/ME/2000 READ ME FIRST Windows 98/ME/2000 *DSL Equipment Installation Guide: Alcatel Speed Touch PC *Digital Subscriber Line Part Number: AlcatelPC9x02A Version 1.2-A Table of Contents Follow Steps 1 through 7

More information

SymSYNC TM User s Guide

SymSYNC TM User s Guide 1603-9821 SymSYNC TM User s Guide Cautions and Warnings Refer to the Simplex 125 User s Guide (Part No. 574-169) for all appropriate Cautions and Warnings. Introduction This publication shows how to install,

More information

JPRO Fleet Service Portal User s Guide

JPRO Fleet Service Portal User s Guide JPRO Fleet Service Portal User s Guide 1 System Requirements Supported Operating Systems Windows 2000 Windows XP Hardware Requirements Minimum: 128 MB RAM, 2 GB HD, Pentium II, 1024 x 768 monitor Recommended:

More information

Radio Control Programmer Software Revision History. Revision History

Radio Control Programmer Software Revision History. Revision History Radio Control Programmer Software Revision History Revision History Version 2.5.4 (General Availability): (May 25, 2016) Fix issue with device configuration data being overwritten. (Bug #900) Version 2.5.3

More information

Print Server using HPMv7 Customer Installation Document

Print Server using HPMv7 Customer Installation Document Print Server using HPMv7 Customer Installation Document (For Go! Res 4.x Installations) Table of Contents I. Introduction 2 II. System Requirements / Environment 2 III. Worldspan GDS Printers & Cabling

More information

FREQUENTLY ASKED QUESTIONS

FREQUENTLY ASKED QUESTIONS Intelligent Device Manager AMS Device Manager 9.0 FREQUENTLY ASKED QUESTIONS For Customer Distribution Page 1 of 6 AMS Suite: Intelligent Device Manager 9.0 Emerson Process Management is pleased to announce

More information

Expert Software Manual for Tritex II AC & DC Actuators and EXP-24 Controllers

Expert Software Manual for Tritex II AC & DC Actuators and EXP-24 Controllers Expert Software Manual for Tritex II AC & DC Actuators and EXP-24 Controllers Information furnished by Exlar Corporation is believed to be accurate and reliable. However, no responsibility is assumed by

More information

Device Management System

Device Management System Device Management System [R 31] 1. What is InnovativeField Organizer? InnovativeField Organizer (hereinafter IFO) is a device management system for smart field devices that supports FOUNDATION fieldbus

More information

ShineNet. Growatt Version Date Notes New. ShineNet V1.0

ShineNet. Growatt Version Date Notes New. ShineNet V1.0 ShineNet Growatt 1.0 2012-09-25 Version Date Notes 1.0.0.2 2012-09-25 New Table of Contents 1. Introduction...3 2. Install and Uninstall...4 2.1 System requirements...4 2.2 Install software...4 2.3 Uninstall

More information

READ ME FIRST. Windows NT. *DSL Equipment Installation Guide: Efficient Networks 5260

READ ME FIRST. Windows NT. *DSL Equipment Installation Guide: Efficient Networks 5260 READ ME FIRST Windows NT *DSL Equipment Installation Guide: Efficient Networks 5260 *Digital Subscriber Line Part Number: 5260NT02A Version 1.2-A. Table of Contents Follow Steps 1 through 8 to complete

More information

Safe Access User manual

Safe Access User manual 1 Table of contents 1. A new way to access e-banking services... 3 2. Prerequisites for installation... 3 3. Installation... 4 4. Running... 8 5. Folder shared with the PC... 9 6. Displaying documents...

More information

1 System Requirements

1 System Requirements START User s Guide (Use with START version 2.9.1 or higher) Click to: Review the START Main Menu Download Software View Operator History Logs Enter Operator Menu Settings Perform Operator Diagnostics 1

More information

Upgrading the Cisco ONS CL to Release 7.0

Upgrading the Cisco ONS CL to Release 7.0 This document explains how to upgrade Cisco ONS 15310-CL Cisco Transport Controller (CTC) software from Release 5.x or Release 6.x to Release 7.0.x, or from Release 7.0.x to a later maintenance release

More information

Entis XL. Software Installation. Copyright 2004 Enraf Ltd Page 1 of 29

Entis XL. Software Installation. Copyright 2004 Enraf Ltd Page 1 of 29 Entis XL Software Copyright 2004 Enraf Ltd Page 1 of 29 Contents Section Description Page 0.0 Legal 0-4 0.1 Copyright 0-4 0.2 Disclaimer 0-4 0.3 Safety Notice 0-4 1.0 General Guidelines 1-5 2.0 of Entis

More information

GP-N100 Utility Software Manual

GP-N100 Utility Software Manual System Requirements En Thank you for your purchase of a GP-N100. This manual describes how to use the GP-N100 Utility to download the latest assisted GPS data from Nikon servers to your GP-N100. To ensure

More information

INSTALLATION AND USER GUIDE

INSTALLATION AND USER GUIDE INSTALLATION AND USER GUIDE Introduction 1 Introduction About 6140 Agent Portal Mitel Networks 6140 Agent Portal allows an agent to receive call information via a number of different applications that

More information

Outlook 2003 Desktop Configuration for Remote Access User Guide

Outlook 2003 Desktop Configuration for Remote Access User Guide Outlook 2003 Desktop Configuration for Remote Access User Guide Outlook 2003 Desktop Configuration for Remote Access 1 of 9 Transferring Microsoft Outlook Data How to Export Personal Folders (.pst) File

More information

Installation Guide. Version 2600

Installation Guide. Version 2600 Installation Guide Version 2600 Before You Start Check here to see that your PC has what it needs to run FedEx Ship Manager Software: Minimum System and Hardware Requirements Intel Pentium 4, 2.4 GHz recommended

More information

LCC-S Configuration software for transmitters

LCC-S Configuration software for transmitters LCC-S Configuration software for transmitters Table of contents 1. Introduction...5 2. Software installation...5 2.1. Minimum system requirement...5 2.2. Installing the software...5 3. Start with the

More information

Using BlueStep Backup

Using BlueStep Backup Using BlueStep Backup BlueStep Backup Your data is an invaluable resource. To protect and store critical digital documents and files, BlueStep Technologies offers the ideal technological solution - BlueStep

More information

FUJI HART EXPLORER INSTRUCTION MANUAL

FUJI HART EXPLORER INSTRUCTION MANUAL FUJI HART EXPLORER INSTRUCTION MANUAL 14/09/2010 1/76 Contents CONTENTS 2 VERSIONS 6 ABOUT THIS GUIDE 7 Purpose 7 Audience 7 Scope 7 FUJI ELECTRIC FRANCE Contact Information 7 INSTALLING THE APPLICATION

More information

1.0. User s Guide & Manual. MDC Bluetooth + 56K Modem

1.0. User s Guide & Manual. MDC Bluetooth + 56K Modem 1.0 MDC Bluetooth + 56K Modem User s Guide & Manual Portable of module Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class

More information

Windows Download & Installation

Windows Download & Installation BrokerMetrics / AgentMetrics Instructions for a New Installation Windows Download & Installation... 1 Macintosh Download & Installation... 6 Troubleshooting... 10 How to verify your installation... 11

More information

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer This manual explains how to connect the HiDMUX2700 HART Multiplexer and configure Yokogawa s Plant Resource Manager (PRM) software.

More information

PMS 138 C Moto Black spine width spine width 100% 100%

PMS 138 C Moto Black spine width spine width 100% 100% Series MOTOROLA and the Stylized M Logo are registered in the US Patent & Trademark Office. All other product or service names are the property of their respective owners. 2009 Motorola, Inc. Table of

More information

XLmanage Version 2.4. Installation Guide. ClearCube Technology, Inc.

XLmanage Version 2.4. Installation Guide. ClearCube Technology, Inc. XLmanage Version 2.4 Installation Guide ClearCube Technology, Inc. www.clearcube.com Copyright and Trademark Notices Copyright 2009 ClearCube Technology, Inc. All Rights Reserved. Information in this document

More information

Camera Integration Note

Camera Integration Note OneHome Management and Control Solutions Camera Integration Note Manufacturer: Panasonic Model Number(s): OneHome Versions: BL-C1A, BL-C20A (wireless) 4.0 build 1310 or newer Comments: Network Camera (version

More information

READ ME FIRST Windows 95/98/Me/2000

READ ME FIRST Windows 95/98/Me/2000 READ ME FIRST Windows 95/98/Me/2000 *DSL Equipment Installation Guide: Efficient Networks 5260 *Digital Subscriber Line Part Number: 52609x02 Version 1.2-A Table of Contents Follow Steps 1 through 8 to

More information

Microsoft Windows Servers 2012 & 2016 Families

Microsoft Windows Servers 2012 & 2016 Families Version 8 Installation Guide Microsoft Windows Servers 2012 & 2016 Families 2301 Armstrong St, Suite 2111, Livermore CA, 94551 Tel: 925.371.3000 Fax: 925.371.3001 http://www.imanami.com Installation Guide

More information

FRONTLINE TEST SYSTEM

FRONTLINE TEST SYSTEM FRONTLINE TEST SYSTEM SETUP AND QUICK START GUIDE ETHERTEST 04 Feb 09 300 DOC ET 000 Copyright 2000 2009 Frontline Test Equipment, Inc. All rights reserved. You may not reproduce, transmit, or store on

More information

Setting up FT3000 and version on Windows 7. This is a step by step guide for setting up the FT3000 on a new Windows 7 or 8 PC

Setting up FT3000 and version on Windows 7. This is a step by step guide for setting up the FT3000 on a new Windows 7 or 8 PC Setting up FT3000 and version 3.0.1 on Windows 7 This is a step by step guide for setting up the FT3000 on a new Windows 7 or 8 PC PROBLEM: Computer being updated from XP to WIN 7 or 8. New PC does not

More information

GP2X USB Accelerometer Quick Start Guide

GP2X USB Accelerometer Quick Start Guide GP2X USB Accelerometer Quick Start Guide 1 Getting started 1.1 Installing the Software Before installing the software take a moment and verify that the computer meets the following minimum systems requirements:

More information

Professional. User Guide. Professional. User Guide MN-PCMPRO-EN-06 (REV. 07/2010)

Professional. User Guide. Professional. User Guide MN-PCMPRO-EN-06 (REV. 07/2010) h t t p : / / w w w. l a p l i n k. c o m / h e l p Tel (USA): +1 (425) 952-6001 Fax (USA): +1 (425) 952-6002 E-mail us at CustomerService@laplink.com Tel (UK): +44 (0) 870-2410-983 Fax (UK): +44 (0) 870-2410-984

More information

GO! Finder V1.4. User Manual

GO! Finder V1.4. User Manual GO! Finder V1.4 User Manual 1 Tables of Contents GO! Finder Introduction-------------------------------------------------------------------------------------1 System Requirements ---------------------------------------------------------------------------------------2

More information

Accessing Carolinas Healthcare System Resources Remotely

Accessing Carolinas Healthcare System Resources Remotely Accessing Carolinas Healthcare System Resources Remotely Have you logged in remotely before? If not, please proceed to Step 1. If yes, please log in as normal or see FAQ section if you are having trouble

More information

Firmware, Database, & PC Application Update Installation Instructions

Firmware, Database, & PC Application Update Installation Instructions Firmware, Database, & PC Application Update Installation Instructions IMPORTANT Please read before you begin the installation. To avoid possible errors, it is recommended to install the updates as described

More information

Function Point WORKBENCH Release 7.0k INSTALLATION GUIDE TABLE OF CONTENTS

Function Point WORKBENCH Release 7.0k INSTALLATION GUIDE TABLE OF CONTENTS Function Point WORKBENCH Release 7.0k GUIDE TABLE OF CONTENTS FUNCTION POINT WORKBENCH RELEASE 7.0K GUIDE... 1 LICENCE TYPES... 3 Standalone Licence Machine Dependent (Single User)... 3 Network Licence

More information

HART Field Device Specification Fisher FIELDVUE DVC6200 SIS Digital Valve

HART Field Device Specification Fisher FIELDVUE DVC6200 SIS Digital Valve Instruction Manual Supplement DVC6200 SIS Digital Valve Controller HART Field Device Specification Fisher FIELDVUE DVC6200 SIS Digital Valve Controller HART Revision Device Type Device Revision Firmware

More information

Bluetooth Application Note

Bluetooth Application Note Bluetooth Application Note FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits

More information

Aspera Connect Windows XP, 2003, Vista, 2008, 7. Document Version: 1

Aspera Connect Windows XP, 2003, Vista, 2008, 7. Document Version: 1 Aspera Connect 2.6.3 Windows XP, 2003, Vista, 2008, 7 Document Version: 1 2 Contents Contents Introduction... 3 Setting Up... 4 Upgrading from a Previous Version...4 Installation... 4 Set Up Network Environment...

More information

Host software Plunger Analysis System. Enterprise workbench for optimization, fault detection, simulation, and training.

Host software Plunger Analysis System. Enterprise workbench for optimization, fault detection, simulation, and training. Administration Guide/2105844-MN Rev. AA Host software Plunger Analysis System Enterprise workbench for optimization, fault detection, simulation, and training. Contents Health and Safety... vii General

More information

User Guide. PCmover Professional for Windows XP. Laplink Software, Inc. User Guide MN-PCMPRO-XP-EN-08 (REV. 2014/07/08)

User Guide. PCmover Professional for Windows XP. Laplink Software, Inc. User Guide MN-PCMPRO-XP-EN-08 (REV. 2014/07/08) 1 PCmover Professional The Only Software that Moves Programs, Files, and Settings to a New PC! Laplink Software, Inc. Customer Service/Technical Support: Web: http://www.laplink.com/contact E-mail: CustomerService@laplink.com

More information

BrightCore BACnet Lookout V2.2 Product Family

BrightCore BACnet Lookout V2.2 Product Family Page 1 BrightCore BACnet Lookout User Guide Essential, Standard and Extended v.2.2 Page 2 Copyright 2013 by ELMA Kurtalj ltd. All rights reserved. The contents of this documentation are taken in part from

More information

FarStone RestoreIT Users Guide

FarStone RestoreIT Users Guide FarStone RestoreIT 2014 Users Guide Copyright Notice No part of this publication may be copied, transmitted, stored in a retrieval system or translated into any language in any form or by any means without

More information

SafePlace User manual

SafePlace User manual SafePlace 1 SafePlace Table of contents 1. A new way to access e-banking services... 3 2. Prerequisites for SafePlace installation... 3 3. SafePlace Installation... 3 4. Running SafePlace... 6 5. Folder

More information

FileMaker. Mobile 2.1. User s Guide. For Windows, Mac, Palm OS, and Pocket PC. Companion for Palm OS and Pocket PC

FileMaker. Mobile 2.1. User s Guide. For Windows, Mac, Palm OS, and Pocket PC. Companion for Palm OS and Pocket PC For Windows, Mac, Palm OS, and Pocket PC FileMaker Mobile 2.1 Companion for Palm OS and Pocket PC User s Guide 2000-2002 FileMaker, Inc. All Rights Reserved. FileMaker, Inc. 5201 Patrick Henry Drive Santa

More information

Remote Deposit Service

Remote Deposit Service Remote Deposit Service Start Up Guide *Screen shots are shown for illustrative purposes only and may vary based on the version of Windows you are currently using. Step 1: Confirm your PC meets system

More information

NORDSON CORPORATION AMHERST, OHIO USA

NORDSON CORPORATION AMHERST, OHIO USA CanWorks Operator Interface Tracking PLUS for CanWorks Systems with SM-2 Spray Monitors User Guide Part 1018132A NORDSON CORPORATION AMHERST, OHIO USA 2002 Nordson Corporation. All rights reserved. CanWorks,

More information

Radio Control Programmer Software Revision History. Revision History

Radio Control Programmer Software Revision History. Revision History Radio Control Programmer Software Revision History Revision History Version 2.4.5 (General Availability): (January 19, 2016) Issue #837 Address issues with FDP programming that can cause the device to

More information

CITO2 Installation & User Instructions

CITO2 Installation & User Instructions CITO2 Installation & User Instructions DD 56107 Stoneridge Electronics Ltd 1. Installation...4 1.1. System Requirements...4 1.2. Installing CITO2...4 1.3. Uninstalling CITO2...4 2. Starting and closing

More information

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures. Agilent SureCall 3.5 Installation Guide For Research Use Only. Not for use in diagnostic procedures. Agilent Technologies Notices Agilent Technologies, Inc. 2016 No part of this manual may be reproduced

More information

Secure Single Sign On with FingerTec OFIS

Secure Single Sign On with FingerTec OFIS Secure Single Sign On with FingerTec OFIS User Guide CONTENTS 3 1 INTRODUCTION Welcome to OFIS Gateway 4-11 2 INSTALLATION & SETUP Registering Your OFIS Gateway Installing & Setting Up Your OFIS Gateway

More information

NOTICE: This document contains references to Varian. Please note that Varian, Inc. is now part of Agilent Technologies. For more information, go to

NOTICE: This document contains references to Varian. Please note that Varian, Inc. is now part of Agilent Technologies. For more information, go to NOTICE: This document contains references to Varian. Please note that Varian, Inc. is now part of Agilent Technologies. For more information, go to www.agilent.com/chem. Varian MS Workstation 6.9 Service

More information

How to Install, Configure and Use sftp (Windows Version)

How to Install, Configure and Use sftp (Windows Version) How to Install, Configure and Use sftp (Windows Version) The sftp secure File Transfer Protocol allows you to transfer patient datasets to and from IDT s server securely. All data transfers are encrypted

More information

Contents. Getting Started...1. Managing Your Drives...9. Backing Up & Restoring Folders Synchronizing Folders...52

Contents. Getting Started...1. Managing Your Drives...9. Backing Up & Restoring Folders Synchronizing Folders...52 Contents Getting Started.....................................................1 Installing the Software...........................................1 Using the Maxtor System Tray Icon................................6