Using Pinnacle 16 Deformable Image registration in a re-treat scenario
|
|
- Theodore Ferguson
- 5 years ago
- Views:
Transcription
1 Introduction Using Pinnacle 16 Deformable Image registration in a re-treat scenario This short Hands On exercise will introduce how the Deformable Image Registration (DIR) tools in Pinnacle can be used in a Re-treat workflow. The scenario we will consider is as follows 1. Patient has already received a treatment (in this case a VMAT Head & Neck) at another centre. 2. The patient is now referred for further radiotherapy 3. A new planning CT scan is performed 4. We need to consider the dose from the old treatment in designing the current treatment. The detailed steps in the workflow are 1. The original plan was performed on image Scan1 1. This is Original Plan in the training case. 2. A planning CT has been acquired `Scan2 3. The new planning CT (scan2) is imported Pinnacle as the primary dataset and some contouring has been performed on it. 4. The old planning CT (scan1) has been imported into the same plan as a secondary dataset 5. The DicomRT Dose from the original plan has been sent to Pinnacle 6. The original plans RT Dose is imported onto the original planning CT (scan1) 1. The ability to import RT Dose onto a secondary image was introduced in Pinnacle Deformable Image Registration is performed between scan1 & scan2 8. The resulting Deformation Vector Field (DVF) is applied to the imported dose to propagate it onto the new planning CT (scan2) 9. In the design of the new treatment plan on Scan2 the previous dose can be accounted for. Getting Started Select patient head_and_neck and plan CopyMeToStartExercise Copy this plan Note, in this plan scan2 is the primary image and scan1, the old planning CT, is the secondary Enter Fusion Page 1 of 7
2 Some contouring has already been performed on scan2 Importing the old dose. Select File - Import DICOM and select patient head_and_neck from the list Select the RT Dose from the available messages and select Import Select OK to the following message Page 2 of 7
3 The Record Viewer window will open showing the imported dose. The imported dose is automatically associated with the correct image. In the Evaluation tab in the Record Viewer note that the Dose Type is set to imported Close the record viewer window and the Import DICOM window. Page 3 of 7
4 Creating a Deformation between old and new planning CTs Go to the Deformation tab in Fusion Select Primary Image Modality = CT Filter Images = Yes Smoothing = 1.5 Select Create Deformed Image Note, in this case we are only performing a deformable registration for reasons of brevity. In practice the two images are likely to be more different than in this example so a rigid registration would be performed before the deformable. The initial rigid registration gives the deformable a better starting point. Using the tools introduced in the previous exercise ensure the deformation is acceptable. Approve the Deformation Once approved it will change to the screen shot below Page 4 of 7
5 Propagating the old dose onto the new planning CT Select ctrl P to open the Prescription window Select the dose display mode as Prior Dose Only and Select Manage Prior Dose to open the Prior Dose Manager Under the Include column select Deformed. Rigid is not available as only deformable registration has been approved. Page 5 of 7
6 The previously delivered dose will now propagate to the new planning CT (scan2) and the display will state Prior Dose Only Orange line indicates limit of Deformed Dose The thick orange line is the 1% isodose line (it is 1% of the maximum dose) and is displayed to show the limits of where dose has been propagated to. It can be switched off by switching off display of the dose grid. If dose is required outside of this the dose grid can be redrawn in Planning. Note, that dose will only be propagated where the DVF exists. If a bounding box has been used for the DIR then the dose will only be present inside the bounding box. In the Manage Prior Dose window adjust the scale factor and observe the change in the dose displayed on scan2. This can be used to scale dose from previous treatments to allow for any tissue repair. Note; the scaling of prior dose can be used for tissue repair just for one critical organ. E.g. cord. As not all organs repair by the same percentage. It can also be used if the previous treatment was not completed. Page 6 of 7
7 Note that in the Manage Prior Dose window Selected For Treatment & Clinically Valid have no status as we have used Dose imported from outside Pinnacle. If the Prior dose was generated in Pinnacle then these would be have values. Continue with new treatment plan on scan2 This is the end of this exercise. Now the previous dose has been propagated onto the new planning CT (scan2) it can be accounted for in the design of a new treatment plan. To display the total dose resulting from both treatments the Dose display mode can be set to Current Dose & Prior Dose. In addition, Pinnacle 3 16 adds a new RT Dose export option so that the sum of Current and Prior dose can be exported. Page 7 of 7
Virtual Phantoms for IGRT QA
TM Virtual Phantoms for IGRT QA Why ImSimQA? ImSimQA was developed to overcome the limitations of physical phantoms for testing modern medical imaging and radiation therapy software systems, when there
More informationADVANCING CANCER TREATMENT
3 ADVANCING CANCER TREATMENT SUPPORTING CLINICS WORLDWIDE RaySearch is advancing cancer treatment through pioneering software. We believe software has un limited potential, and that it is now the driving
More informationREAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT
REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT Anand P Santhanam Assistant Professor, Department of Radiation Oncology OUTLINE Adaptive radiotherapy for head and
More informationVALIDATION OF DIR. Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology
VALIDATION OF DIR Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology Overview Basics: Registration Framework, Theory Discuss Validation techniques Using Synthetic CT data & Phantoms What metrics to
More informationGood Morning! Thank you for joining us
Good Morning! Thank you for joining us Deformable Registration, Contour Propagation and Dose Mapping: 101 and 201 Marc Kessler, PhD, FAAPM The University of Michigan Conflict of Interest I receive direct
More informationNA-MIC National Alliance for Medical Image Computing Subject Hierarchy
NA-MIC Subject Hierarchy Csaba Pinter Queen s University, Canada csaba.pinter@queensu.ca NA-MIC Tutorial Contest: Winter 2016 Learning Objective This tutorial demonstrates the basic usage and potential
More informationADVANCING CANCER TREATMENT
The RayPlan treatment planning system makes proven, innovative RayStation technology accessible to clinics that need a cost-effective and streamlined solution. Fast, efficient and straightforward to use,
More informationUse of Deformable Image Registration in Radiation Therapy. Colin Sims, M.Sc. Accuray Incorporated 1
Use of Deformable Image Registration in Radiation Therapy Colin Sims, M.Sc. Accuray Incorporated 1 Overview of Deformable Image Registration (DIR) Algorithms that can deform one dataset to another have
More informationSlicerRT Image-guided radiation therapy research toolkit for 3D Slicer
SlicerRT Image-guided radiation therapy research toolkit for 3D Slicer Csaba Pinter 1, Andras Lasso 1, An Wang 2, David Jaffray 2, and Gabor Fichtinger 1 1Laboratory for Percutaneous Surgery, Queen s University,
More informationATC Conformance Statement Overview
Advanced-Technology QA Consortium DICOM Workshop: ATC Conformance Statement Overview Walter R. Bosch, D.Sc. ATC DICOM Conformance Statement Overview DICOM Part 10 File Set Reader Application (ITC) Defines
More informationradiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li NCAAPM Spring Meeting 2010 Madison, WI
GPU-Accelerated autosegmentation for adaptive radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li agodley@mcw.edu NCAAPM Spring Meeting 2010 Madison, WI Overview Motivation Adaptive
More informationHelp Guide. mm Copyright Mirada Medical Ltd, Mirada Medical RTx 1
Help Guide mm3237-1.6-1 Copyright Mirada Medical Ltd, 2000-2014. Mirada Medical RTx 1 Contents Help Guide... 1 Contents... 2 Introduction to RTx... 4 Regulatory Statement... 6 Notes... 15 Data Supported...
More informationIs deformable image registration a solved problem?
Is deformable image registration a solved problem? Marcel van Herk On behalf of the imaging group of the RT department of NKI/AVL Amsterdam, the Netherlands DIR 1 Image registration Find translation.deformation
More informationDosimetric Analysis Report
RT-safe 48, Artotinis str 116 33, Athens Greece +30 2107563691 info@rt-safe.com Dosimetric Analysis Report SAMPLE, for demonstration purposes only Date of report: ----------- Date of irradiation: -----------
More informationURGENT IMPORTANT FIELD SAFETY NOTIFICATION
Subject: Incorrect Movement of the Treatment Table Product: MOSAIQ Scope: Sites affected will be those: 1. Running MOSAIQ and, 2. Treating on linear accelerators with the RATM license Notification Released:
More informationXD 3.6 Release Notes
XD 3.6 Release Notes 1 Introduction 1.1 Purpose The purpose of these Release Notes is to: 1.2 Scope Communicate any known limitations for Mirada s XD release. Provide information on certain product features.
More informationTG 132: Use of Image Registration and Fusion in RT
TG 132: Use of Image Registration and Fusion in RT Kristy K Brock, PhD, DABR, FAAPM Associate Professor Department of Radiation Oncology, University of Michigan Chair, AAPM TG 132: Image Registration and
More informationSlicerRT radiation therapy extension for 3D Slicer DICOM aspects
SlicerRT radiation therapy extension for 3D Slicer DICOM aspects Andras Lasso, Csaba Pinter Laboratory for Percutaneous Surgery, Queen s University, Canada Commercial treatment planning systems (TPS) Expensive
More informationNA-MIC National Alliance for Medical Image Computing SlicerRT Extension
NA-MIC SlicerRT Extension Csaba Pinter 1, Andras Lasso 1, Kevin Wang 2 11 Laboratory for Percutaneous Surgery, Queen s University, Canada 2 University Health Network, Toronto, ON, Canada pinter@cs.queensu.ca
More informationCaseaccess 1.0 DICOM Conformance Statement
Caseaccess 1.0 DICOM Conformance Statement 1 Introduction 1.1 Integration and Features The integration of medical devices may require functions that are beyond the scope of the DICOM standard. Consequently,
More informationImage Co-Registration II: TG132 Quality Assurance for Image Registration. Image Co-Registration II: TG132 Quality Assurance for Image Registration
Image Co-Registration II: TG132 Quality Assurance for Image Registration Preliminary Recommendations from TG 132* Kristy Brock, Sasa Mutic, Todd McNutt, Hua Li, and Marc Kessler *Recommendations are NOT
More informationTomotherapy archive structure and new software tool for loading and advanced analysis of data contained in it
reports of practical oncology and radiotherapy 1 6 (2 0 1 1) 58 64 available at www.sciencedirect.com journal homepage: http://www.rpor.eu/ Original article Tomotherapy archive structure and new software
More informationDeformable Image Registration, Contour Propagation and Dose Mapping: 101 and 201. Please do not (re)redistribute
Deformable Registration, Contour Deformable Registration, Contour Propagation and Dose Mapping: 101 and 201 Marc Kessler, PhD The University of Michigan Jean Pouliot, PhD University of California Learning
More informationImplementation of Advanced Image Guided Radiation Therapy
Image Acquisition Course Outline Principles, characteristics& applications of the available modalities Image Processing in the T x room Image guided treatment delivery What can / can t we do in the room
More informationA Generation Methodology for Numerical Phantoms with Statistically Relevant Variability of Geometric and Physical Properties
A Generation Methodology for Numerical Phantoms with Statistically Relevant Variability of Geometric and Physical Properties Steven Dolly 1, Eric Ehler 1, Yang Lou 2, Mark Anastasio 2, Hua Li 2 (1) University
More informationOverview of Proposed TG-132 Recommendations
Overview of Proposed TG-132 Recommendations Kristy K Brock, Ph.D., DABR Associate Professor Department of Radiation Oncology, University of Michigan Chair, AAPM TG 132: Image Registration and Fusion Conflict
More informationBasic Dicom Module Options
Basic Dicom Module Options Updated October 2, 2013 There are several methods for getting Dicom images into a patient s chart. The first option involves using the Image Capture Importer module which allows
More informationThe IORT Treatment Planning System. radiance. GMV, 2012 Property of GMV All rights reserved
The IORT Treatment Planning System radiance Property of GMV All rights reserved WHY RADIANCE? JUSTIFICATION Property of GMV All rights reserved ADVANTAGES OF IORT PRECISION: RT guided by direct vision.
More informationWhat s new in. teamplay? Discover the latest features and functionalities. siemens.com/teamplay
What s new in teamplay? Discover the latest features and functionalities siemens.com/teamplay Dear teamplay user, Today, over 1,000 institutions are using teamplay. With a new software version ready for
More informationIntegrated proton-photon treatment planning
Pinnacle 3 Proton Planning Integrated proton-photon treatment planning Philips Pinnacle 3 Proton Planning specifications Pinnacle 3 Proton Planning is designed to simplify treatment planning for proton
More informationADAPTIVE HYBRID SURGERY ANALYSIS
ADAPTIVE HYBRID SURGERY ANALYSIS Version 1.0 Software User Guide Revision 1.1 Copyright 2015, Brainlab AG Germany. All rights reserved. TABLE OF CONTENTS TABLE OF CONTENTS GENERAL INFORMATION...5 Contact
More informationDICOM Conformance Statement RT Elements Document Revision 5 December 14, Copyright Brainlab AG
Document Revision 5 December 14, 2018 2018 Copyright Brainlab AG 1 Conformance Statement Overview This is a Conformance Statement for the Brainlab Radiotherapy system. This system dependent from purchased
More information8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA
PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA Jennifer R. Clark, M.S., DABR Conflict of Interest Statement: I am an employee of Sun Nuclear Corporation Outline: Platform overview
More informationEvaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems
University of Wollongong Research Online Faculty of Engineering and Information Sciences - Papers: Part A Faculty of Engineering and Information Sciences 2015 Evaluation of 3D Gamma index calculation implemented
More informationPCRT 3D. Scalable Architecture System. User-Friendly. Traceable. Continuos Development
PCRT 3D The PCRT3D is a versatile 3D radiation treatment planning system featuring the most accurate algorithm calculations, the latest techniques in virtual simulation and the most advanced radiotherapy
More informationCode of practice: Create a verification plan for OCTAVIUS Detector 729 in Philips Pinnacle³
Technical Note D655.208.03/00 Code of practice: Create a verification plan for OCTAVIUS Detector 729 in There are basically three ways to carry out verification of IMRT fluences. For all options, it is
More informationDose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them
Dose Distributions George Starkschall, Ph.D. Department of Radiation Physics U.T. M.D. Anderson Cancer Center Purpose To familiarize the resident with dose distributions and the factors that affect them
More informationCarestream Vita user quick guide. Software version 3.2 From April 2012
Carestream Vita user quick guide Software version 3.2 From April 2012 1 Carestream Vita user quick guide Software version 3.2 from April 2012 1. To switch your Vita on Press the power button on the PC
More informationIMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE
QA SOFTWARE FAST, PRECISE Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, VMAT, SRS and brachytherapy plans no film, no phantoms, no linac
More informationDisplay Layers in Geosoft 3D View
Use the New 2D/3D Workflow features in Target for ArcGIS In Target for ArcGIS version 3.5, there are three new interconnected features that make integrating 2D and 3D data in plan and section maps easier.
More informationInteroperability Issues in Image Registration and ROI Generation
1 DICOM 2005 International Conference, Budapest, Hungary Interoperability Issues in Image Registration and ROI Generation Todd Kantchev PhD, Siemens Molecular Imaging, Oxford, UK 2 Scope The following
More informationEduCase TM EduCase TM Features. Covers all aspects of EduCase TM features and supporting components.
EduCase TM EduCase TM Features Covers all aspects of EduCase TM features and supporting components. Scott Kaylor, M.Ed. Instructional Technologies: CEO Arthur L. Boyer, PhD: Physics Education Director
More information8.0.6 New Features Guide Auto Window/Level Adjustments
8.0.6 New Features Guide Improvements to the feature allow users to quickly and easily set for images. These adjustments will be automatically and consistently applied to similar images. Window/Level Adjustments
More informationiplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration
iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration The iplan Contouring Workstation offers unique and innovative capabilities for faster contouring and consistent segmentation
More informationAutomatic Segmentation of Parotids from CT Scans Using Multiple Atlases
Automatic Segmentation of Parotids from CT Scans Using Multiple Atlases Jinzhong Yang, Yongbin Zhang, Lifei Zhang, and Lei Dong Department of Radiation Physics, University of Texas MD Anderson Cancer Center
More informationDICOM Conformance Statement RT Elements Document Revision 3 January 19, Copyright Brainlab AG
Document Revision 3 January 19, 2017 2017 Copyright Brainlab AG 1 Conformance Statement Overview This is a Conformance Statement for the Brainlab Radiotherapy system. This system dependent from purchased
More informationSystem Messages for MRIdian 4.1
L 0063 System Messages for MRIdian 4.1 April 2016 SY00001 System found auto recover data on startup during system startup check. System shutdown when while plan was open. The system found plan recovery
More informationDICOM Conformance Statement Radiotherapy Document Revision 2 July 1, Copyright Brainlab AG
Document Revision 2 July 1, 2014 2014 Copyright Brainlab AG 1 Conformance Statement Overview This is a Conformance Statement for the Brainlab system. This system dependent from purchased licenses and
More informationAmateurism Certification
Amateurism Certification NCAA Amateurism Certification 2 Requesting Final Amateurism Certification Navigate to your "My Planner" page by logging onto your account at www.eligibilitycenter.org. Then select
More informationVIEW. a short tutorial. quick start
VIEW a short tutorial quick start VERSiON 3.0 Contents Inhalt Introduction........................................................... 3 Import of DICOM media....................................................
More informationIMRT site-specific procedure: Prostate (CHHiP)
IMRT site-specific procedure: Prostate (CHHiP) Scope: To provide site specific instructions for the planning of CHHIP IMRT patients Responsibilities: Radiotherapy Physicists, HPC Registered Therapy Radiographers
More informationAdvanced Targeting Using Image Deformation. Justin Keister, MS DABR Aurora Health Care Kenosha, WI
Advanced Targeting Using Image Deformation Justin Keister, MS DABR Aurora Health Care Kenosha, WI History of Targeting The advance of IMRT and CT simulation has changed how targets are identified in radiation
More informationIHE Radiation Oncology Technical Framework Supplement. Treatment Delivery Workflow (TDW) Draft for Public Comment
Integrating the Healthcare Enterprise IHE Radiation Oncology Technical Framework Supplement Treatment Delivery Workflow (TDW) Draft for Public Comment Date: January 29, 2010 Author: David Murray Email:
More informationMethodological progress in image registration for ventilation estimation, segmentation propagation and multi-modal fusion
Methodological progress in image registration for ventilation estimation, segmentation propagation and multi-modal fusion Mattias P. Heinrich Julia A. Schnabel, Mark Jenkinson, Sir Michael Brady 2 Clinical
More informationInitial Clinical Experience with 3D Surface Image Guidance
Initial Clinical Experience with 3D Surface Image Guidance Amanda Havnen-Smith, Ph.D. Minneapolis Radiation Oncology Ridges Radiation Therapy Center Burnsville, MN April 20 th, 2012 Non-funded research
More informationAtlas-Based Autosegmentation. DICOM Conformance Statement DICOM 3.0
DICOM Conformance Statement DICOM 3.0 Revision History, Trademarks ABAS DICOM Conformance Statement Revision History Revision Date Changes ABAS_DCS_100_A 04/2008 First version. ABAS_DCS_B 04/2009 Update
More informationTARDIS Working Practice Document No: 035
TARDIS Working Practice Document No: 035 Uploading CT or MR Images All stroke patients should have a baseline scan taken before randomisation. Any other CT scans or MRIs, taken up until completion of the
More informationIHE Radiation Oncology Technical Framework Supplement. Treatment Delivery Plan Content (TDPC) Rev. 1.1 Trial Implementation
Integrating the Healthcare Enterprise 5 IHE Radiation Oncology Technical Framework Supplement 10 Treatment Delivery Plan Content 15 Rev. 1.1 Trial Implementation 20 Date: November 16, 2016 Author: IHE
More informationTomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram
TomoTherapy Related Projects An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram Development of A Novel Image Guidance Alternative for Patient Localization
More informationSecondary 3D Dose QA Fully Automated using MOSAIQ's IQ Engine. MOSAIQ User Meeting May Antwerp
Secondary 3D Dose QA Fully Automated using MOSAIQ's IQ Engine MOSAIQ User Meeting May 31 2013 - Antwerp Contents Project goal and collaboration Secondary 3D Dose QA project justification Secondary 3D Dose
More informationBasic Radiation Oncology Physics
Basic Radiation Oncology Physics T. Ganesh, Ph.D., DABR Chief Medical Physicist Fortis Memorial Research Institute Gurgaon Acknowledgment: I gratefully acknowledge the IAEA resources of teaching slides
More informationRTx Release Notes. Communicate any known limitations for the RTx release. Provide information on certain product features.
RTx Release Notes 1 Introduction 1.1 Purpose The purpose of these Release Notes is to: 1.2 Scope Communicate any known limitations for the RTx release. Provide information on certain product features.
More informationRelease 7.4 Commercial Update 3 August 4, 2017
These Release Notes announce the distribution of Release 7.4 Commercial Update 3, which includes enhancements and problem fixes since the June 21, 2017 release of 7.4 Commercial Update 2.1. Important Note:
More informationCROSS SECTIONAL IMAGING IN OSIRIX
CROSS SECTIONAL IMAGING IN OSIRIX Supporting Documentation James Ricketts INDEX 1. Importing Images 2. Exporting Images 3. Cutting Down Series 4. Changing the default windowing 5. Anonymise an Ultrasound
More informationPosition accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon
Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon WHITE PAPER Introduction An image guidance system based on Cone Beam CT (CBCT) is included in Leksell
More informationLeksell SurgiPlan Overview. Powerful planning for surgical success
Leksell SurgiPlan Overview Powerful planning for surgical success Making a Difference in Surgical Planning Leksell SurgiPlan Leksell SurgiPlan is an advanced image-based neuro surgical planning software,
More informationUSERS MANUAL. TROG RADAR Study
USERS MANUAL TROG 03.04 RADAR Study PLATO RTOG EXPORT INSTRUCTIONS Version 1 October 2005 1 Table of Contents Requirements...3 Editing the Configuration Files...3 Process...5 Diagnostics...5 2 Requirements
More informationMichael Speiser, Ph.D.
IMPROVED CT-BASED VOXEL PHANTOM GENERATION FOR MCNP MONTE CARLO Michael Speiser, Ph.D. Department of Radiation Oncology UT Southwestern Medical Center Dallas, TX September 1 st, 2012 CMPWG Workshop Medical
More informationAmbra User Guide. If you need help. Ambra Support (any time)
If you need help Ambra Support 888 315 0790 (any time) support@ambrahealth.com Ambra User Guide Envision Radiology, a Health Images Organization, has provided a list of your site s personnel that need
More informationOptimiseRx Prescribers User Guide for EMIS Web
PRODUCT OVERVIEW: OptimiseRx OptimiseRx Fully integrated with the patient record to enable the delivery of prescribing best practice and to optimise cost savings. 2016 First Databank Europe Ltd. A subsidiary
More informationImprovement and Evaluation of a Time-of-Flight-based Patient Positioning System
Improvement and Evaluation of a Time-of-Flight-based Patient Positioning System Simon Placht, Christian Schaller, Michael Balda, André Adelt, Christian Ulrich, Joachim Hornegger Pattern Recognition Lab,
More informationUCare Therapy Authorization Web Application. User Guide
UCare Therapy Authorization Web Application User Guide 1 Table of Contents I. Introduction...3 Contact Information... 3 II. Using the Therapy Authorization System...3 Log On... 3-7 Member Identification...
More informationDICOM Conformance Statement. Leksell GammaPlan & Leksell SurgiPlan 10.2
Name of document DICOM Conformance Statement Regarding Date Leksell GammaPlan & Leksell SurgiPlan 2012-10-15 1 (57) DICOM Conformance Statement Leksell GammaPlan & Leksell SurgiPlan 10.2 2 (57) Contents
More informationCHAPTER 9 INFLUENCE OF SMOOTHING ALGORITHMS IN MONTE CARLO DOSE CALCULATIONS OF CYBERKNIFE TREATMENT PLANS: A LUNG PHANTOM STUDY
148 CHAPTER 9 INFLUENCE OF SMOOTHING ALGORITHMS IN MONTE CARLO DOSE CALCULATIONS OF CYBERKNIFE TREATMENT PLANS: A LUNG PHANTOM STUDY 9.1 INTRODUCTION 9.1.1 Dose Calculation Algorithms Dose calculation
More informationIMPAX Volume Viewing Configuration
Getting started guide IMPAX Volume Viewing Configuration This guide describes the various configuration settings for IMPAX Volume Viewing. Some of these settings are only relevant if a license for one
More informationUse of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No.
Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132 Kristy K. Brock a) Department of Imaging Physics, The University
More informationLucy Phantom MR Grid Evaluation
Lucy Phantom MR Grid Evaluation Anil Sethi, PhD Loyola University Medical Center, Maywood, IL 60153 November 2015 I. Introduction: The MR distortion grid, used as an insert with Lucy 3D QA phantom, is
More informationGPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC
GPU applications in Cancer Radiation Therapy at UCSD Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC Conventional Radiotherapy SIMULATION: Construciton, Dij Days PLANNING:
More informationSlicing. Slice multiple parts 13,0601,1489,1664(SP6P1)
Slicing 13,0601,1489,1664(SP6P1) In this exercise, we will learn how to perform Slicing on multiple part. Slicing is the stage where the printing layers are set according to the printer definition or printing
More informationicatvision Quick Reference
icatvision Quick Reference Navigating the i-cat Interface This guide shows how to: View reconstructed images Use main features and tools to optimize an image. REMINDER Images are displayed as if you are
More informationAccounting for Large Geometric Changes During Radiotherapy. Disclosures. Current Generation DIR in RT 8/3/2016
Accounting for Large Geometric Changes During Radiotherapy Geoff Hugo, Ph.D. Department of Radiation Oncology Virginia Commonwealth University, Richmond, Virginia, USA Disclosures Research support: Philips
More informationA simple method to test geometrical reliability of digital reconstructed radiograph (DRR)
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 11, NUMBER 1, WINTER 2010 A simple method to test geometrical reliability of digital reconstructed radiograph (DRR) Stefania Pallotta, a Marta Bucciolini
More informationPrecisePLAN 2.15 Export
Elekta Limited. DICOM Conformance Statement for PrecisePLAN 2.15 Export (DICOM Release 2.15) 2006 Elekta Limited. All rights reserved. DRC-173-0031-01a DICOM Conformance Statement - PrecisePLAN 2.15 Export
More informationSoftware for glucose data management. Manual
Software for glucose data management Manual Table of contents Fundamentals...2 Icons...3 Home Page...5 Data transfer...7 Print-outs...7 Import/Export...8 Patient...13 Glycaemia...16 List of results...16
More informationReport on the Potential use of CfH PACS for Archiving Radiotherapy Information
Report on the Potential use of CfH PACS for Archiving Radiotherapy Information David Mott, & Sue Chatterton June 2010 North Western Medical Physics Introduction Background Current Archive Methods and Shortcomings
More informationDICOM Conformance Statement ExacTrac 6.2 Document Revision 3 July 6, Copyright Brainlab AG
Document Revision 3 July 6, 2016 2016 Copyright Brainlab AG 1 Conformance Statement Overview This is a conformance statement for the Brainlab software ExacTrac. The DICOM import part of the application
More informationBreast Tomosynthesis: Impact on IT Systems. dondennison.com
Breast Tomosynthesis: Impact on IT Systems MIIT 2016, HAMILTON Don K Dennison Industry consultant with 14+ years experience in imaging IT Society for Imaging Informatics in Medicine (SIIM) Board of Directors
More informationASTRO Integrating the Healthcare Enterprise. IHE-Radiation Oncology Technical Framework Volume 2 - Transactions
ASTRO Integrating the Healthcare Enterprise IHE-Radiation Oncology Technical Framework Volume 2 - Transactions 2008 November 13, 2008 Copyright 2006-2008: ACC/HIMSS/RSNA/ASTRO Contents 1 Preface to Volume
More informationInobitec DICOM Server (PACS) Conformance Statement. Version: 1.4.x
Inobitec DICOM Server (PACS) Conformance Statement Version: 1.4.x Table of Contents Preface...3 1. Overview...4 2. Introduction...6 2.1 Revision History...6 2.2 Audience...6 2.3 Definitions...6 2.4 References...6
More informationAdditional file 1: Online Supplementary Material 1
Additional file 1: Online Supplementary Material 1 Calyn R Moulton and Michael J House School of Physics, University of Western Australia, Crawley, Western Australia. Victoria Lye, Colin I Tang, Michele
More informationAcuo VNA. DICOM Conformance Statement Version 6.0 March 2018
Acuo VNA DICOM Conformance Statement Version 6.0 March 2018 Table of Contents 1 Introduction...3 1.1 AcuoMed and its Conformance to DICOM...3 1.2 AcuoMed Features...3 2 Implementation Model...4 2.1 Application
More informationMedical Image Viewer Guide
Cloud Medical Image Management Medical Image Viewer Guide March 2016 Table of Contents Indications for Use 3 Browser Requirements 3 User Interface Overview 4-5 Study Page 6 Main Toolbar 7 Sub-Toolbars
More information1. Learn to incorporate QA for surface imaging
Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures*** 1. Learn to incorporate QA for surface imaging into current QA procedures for IGRT. 2. Understand
More informationComprehensive treatment planning for brachytherapy. Advanced planning made easy
Comprehensive treatment planning for brachytherapy Advanced planning made easy Oncentra Brachy offers a variety of smart tools that facilitate many of the repetitive tasks for you. In contemporary brachytherapy,
More informationVisage. DICOM Conformance Statement
Visage 7 DICOM Conformance Statement Information about manufacturer and distribution contacts as well as regulatory status of the product can be found in the User Manual. Some of the specifications described
More informationBasics of treatment planning II
Basics of treatment planning II Sastry Vedam PhD DABR Introduction to Medical Physics III: Therapy Spring 2015 Dose calculation algorithms! Correction based! Model based 1 Dose calculation algorithms!
More informationClearCanvas Workstation DICOM Conformance Statement
ClearCanvas Workstation DICOM Conformance Statement Document Version: 2.1 Product Name(s): Component Name(s): Edition(s): ClearCanvas RIS/PACS ClearCanvas Workstation Chiropractic Version: 3.7 Date: July
More informationDICOM 3.0 Conformance Statement **
DICOM 3.0 Conformance Statement ** ** Applicable to MIM 6.1 6.4 and MIMviewer 3.1 3.4 software versions MIM Software Inc. 25800 Science Park Drive Suite 180 Cleveland, Ohio 44122 216-455-0600 (U.S. toll
More informationHugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France. Sunday 17 July 2016
Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France Sunday 17 July 2016 AGENDA 1. Introduction 2. Material 3. Optimization process 4. Results 5. Comments 6. Conclusion
More information(Informatics) Standards for Quantitative Imaging. David A. Clunie PixelMed Publishing & CoreLab Partners
(Informatics) Standards for Quantitative Imaging David A. Clunie PixelMed Publishing & CoreLab Partners Affiliations & Disclosures CTO, CoreLab Partners, Princeton, NJ PixelMed Publishing, Bangor, PA Editor,
More information