1 1993 Specifications CSJ s , etc. & SPECIAL SPECIFICATION 1861 Premium Subrate Data Multiplexer and Distribution Panel 1. Description. This Item shall govern for the furnishing and installing of a T-1 Premium Subrate Data Multiplexer and Distribution Panel and related components. 2. General. The multiplexer data transmission system as described herein shall support a T-1 data stream (1.544 Mb/s) for communication over single mode fiber-optic cable via a nodal network. The multiplexer system shall be fully compliant with AT&T Pub 62411, AT&T Accunet 1.5, and North American PCM DS-1 line per AT&T technical advisory 34 for future interface directly to public carriers offering T-1 service. All required interconnection cables (including the interface electronics between the T-1 multiplexer and DMSs) shall be provided with the associated equipment. (1) Temperature. All equipment shall operate in the temperature range of 32ºF to 122ºF and a relative humidity of 5 to 95% non-condensing. The manufacturer / independent technical laboratory shall supply certification confirming that the equipment complies with these environmental specifications. Units to be installed are subject to field testing as described in Article 7. of this specification. (2) Power Requirements. All equipment defined in this specification shall operate on standard 120 volts AC 60 Hz electrical service. The equipment shall operate over a voltage range of 95 to 135 volts AC. All required interconnection cables (including the interface electronics) between the T-1 Multiplexer and DMSs shall be provided with the associated equipment. (3) T-1 Certification and Support. In order to insure that the equipment is T-1 compliant and that an adequate service organization exists to support the equipment, the T1 multiplexer shall be in active use in at least 1 traffic management application, or 1 wide area network (WAN) or 1 Regional Telephone Company in the United States or major long distance telephone company (ie, AT&T, MCI, Sprint, etc.). A copy of the acceptance of the equipment, by 1 of these companies, or agencies that confirms that the multiplexer is T1 compliant shall be provided as part of the submittal process prior to acceptance of the equipment. The manufacturer of the equipment shall maintain an active service organization. The Contractor shall respond within 8 hours of receipt of a service call
2 3. Interfaces - General. (1) Data Interface. The distribution panel shall provide the following: (a) RS-232, 5 ports. (b) RS to 19.2 kb/s with handshake, subrate asynchronous 5 channel multidrop. (2) Memory Configuration. The configuration of the T-1 node shall be maintained in non-volatile memory or dip switches and shall be secure for power failures exceeding 1 month in duration. The configuration of any node shall be downloadable from the master node. 4. Functional Requirements. Each data channel shall operate in a polled time division multiplexing scheme, the multiplexer may have data channel units sharing the same time slots as other multiplexer data channel units. The multiplexer shall pass signals from the remainder of the 24 channels through to the traffic management center (TMC) as well as passing downstream signals from the TMC on to the rest of the multiplexers. The multiplexer shall be configured as a node in a ring configuration. Each node shall function as a member of the ring. Failure of a node shall be compensated for, with an automatic, self-healing alternate loop path. Transition to the alternate loop shall be seamless to the user, with re-synchronization in less than 250 milliseconds. (1) Equipment Interconnection. Dynamic message signs (DMS) controllers may be located in cabinets external to the communication hub building or as shown on the plans. The communication hub building shall contain the interconnections of the external devices to the video fiber optic transmitter(s), the limited distance modem (LDM) unit(s), and the multiplexer as well as between the connections to the multiplexer and the fiber optic cable plant via the data transceivers. Connection to the multiplexer I/O ports shall use twisted wire pairs and DB-25 connectors based on the channel designations shown on the plans, using the EIA-232 C/D standard. (2) Data Channel Interface. Each asynchronous data channel interface shall be identical and interchangeable throughout the multiplexer system, with a data rate from 300 B/s to 19.2 KB/s with a direct interface via a DB-25 connector to a standard Data Terminal Equipment (DTE). The data interface shall conform to EIA-232-C/D Standard Format. (3) Asynchronous Subrate Data Channel Interface. The Asynchronous Subrate Data Channel Unit shall meet the following requirements: (a) Each card shall provide 5 separate RS-232C channels and 1 diagnostic channel to be multiplexed into a single DSO channel of the T1 data stream. Each RS-232C channel shall be terminated in a separate DB-25 connector. (b) The RS-232 channels shall operate in asynchronous, full duplex mode at aggregate data rates up to 56 KB/s
3 (c) The card shall be suitable for use in 1 slot of a T1 drop/insert multiplexor assembly. The card shall be removable from the front of the assembly. (d) The card shall obtain operating power from the drop/insert multiplexor. (e) The front panel of the card shall contain LED indicators for card status indication. (f) A 19-in. rack mounted panel shall be provided for mounting of DB-25 connectors. The panel shall be mounted such that mounting the DB-25 connectors is accessible from the rear. (g) The card shall support simultaneous operation of all 5 RS-232 channels. (h) All necessary cables and connectors shall be provided with each card. (i) All cards shall be from the same manufacturer. (4) Primary Input Power Interruption. The equipment shall meet all of the requirements in Section 2.1.4, "Power Interruption", of the National Electrical Manufacturers Association (NEMA) Standard TS for Traffic Control Systems, latest revision. (5) Power Service Transients. The equipment shall meet the requirements of Section 2.1.6, "Transients, Power Service", of the NEMA Standard TS , latest revision. (6) Wiring. All wiring shall meet the requirements of the National Electric Code. All wires shall be cut to proper length before assembly. No wire shall be doubled back to take up slack. Wires shall be neatly laced into cable with nylon lacing or plastic straps. Cables shall be secured with clamps. Cable slack shall be provided to facilitate the removal and replacement of assemblies, panels, and modules for maintenance. 5. Mechanical Requirements. (1) Modular Design. The equipment shall be modular in design such that major portions may be readily replaced in the field. Modules of unlike functions shall be mechanically keyed to prevent insertion into the wrong socket or connector. All modules and assemblies shall be clearly identified with name, model number, serial number and any other pertinent information required to facilitate equipment maintenance. (2) Connectors and Harness. All external connections shall be made by means of connectors. The connectors shall be keyed to preclude improper hookups. All wires to and from the connectors shall be color coded and/or appropriately marked. Each and every conductive contact surface or pin shall be plated with a minimum of 50 microns of gold. 6. Construction Methods. All external screws, nuts and locking washers shall be stainless steel. No self-tapping screws shall be used unless specifically approved by the Engineer. All parts shall be made of corrosion resistant material, such as plastic, stainless steel, and anodized aluminum or brass
4 (1) Mechanical Components. All materials used in construction shall be protected from fungus growth and moisture deterioration. Dissimilar metals shall be separated by an inert dielectric material. (2) Electronic Components. All electronic components shall comply with Special Specification, "Electronic Components". Distribution Panels will be furnished as part of proposed Premium Subrate Data Multiplexer and Distribution Panels or, when specified in the plans, furnished and installed on existing Premium Subrate Data Multiplexer units. Asynchronous Subrate Data Channel Units will be furnished as part of proposed Premium Subrate Data Multiplexer and Distribution Panels or, when specified in the plans, furnished and installed on existing Premium Subrate Data Multiplexer and Distribution Panels. 7. Testing. (1) Demonstration Test. The demonstration test shall consist of a shop test bed configured as the field installation. The test bed shall consist of the multiplexer remotes and 1 TMC multiplexer. This test shall demonstrate the following communications capabilities: (a) Network Management Software showing: (1) Network control from the TMC multiplexer. (2) Network diagnostics, ie., calling up each master hub multiplexer, configuring it, resetting it. (3) Graphical display of the multiplexer nodes as installed. (b) Short term BERT test on each of the data channels that shall not exceed 1 in 10 million at 9,600 b/s. (2) Field Subsystem Test. The Contractor shall conduct a data communications subsystem test on each D/I Muldem node after the integration of the multiplexer with the data fiber optic transceivers and the fiber optic network. The test shall, as a minimum, demonstrate data communications between the data channel units in the TMC and the corresponding data channel units in the master hubs and end cabinets. Documentation in a table form shall be filled with the pass/fail test results. If the channel fails, the unit must be repaired and tested again until the test is passed. The Engineer will designate his representative to witness these tests. (3) System Integration Test. The system integration test shall consist of a fully integrated multiplexer with the LDM, and the local cabinet standalone LDM. A short term BERT test between the TMC multiplexer data channels and the local cabinet LDM (loop back plug at the LDM DB-25 connector) shall be done for each channel. The BERT shall not exceed 1 bit error in 10 million bits transmitted
5 Procedures for the referenced tasks for the demonstration tests are to be submitted to the Engineer 60 days prior to examination. The results shall be tabulated and submitted to the Engineer. Procedures for the acceptance test shall be in accordance with Special Specification, "Testing, Training, Documentation, Final Acceptance and Warranty". 8. Training. Training shall be in accordance with Article 2. of Special Specification, "Testing, Training, Documentation, Final Acceptance and Warranty". 9. Instructions and Guarantees. The supplier shall furnish any and all equipment for safe and reliable field operation as part of the quoted price for the specified equipment. All components furnished under this specification shall be current production equipment and of recent manufacturer, identical models of which are in field operation in not less than 2 locations in the United States or Canada. Any repairs made by a manufacturer or representative shall be documented and returned with units when warranty repaired. This documentation shall include an explanation of the exact repairs made and identification of parts replaced by part number and circuit number. All warranty repairs shall be completed within 10 days of delivery of the equipment to the designated repair depot. 10. Submittal Requirements. Six sets of submittal data, i.e., cut sheets (data sheets) for the equipment and software, shall be submitted to the Engineer for review and approval recommendations. 11. Documentation. Six sets of complete schematics and operating manuals (theory of operation) and maintenance manuals of each component shall be supplied with system furnished. The maintenance manuals shall include complete sub-component parts listing and diagnostics procedures. 12. Measurement. Premium Subrate Data Multiplexer and Distribution Panels will be measured by each unit complete in place. Distribution Panels will be measured by each unit complete in place. Asynchronous Subrate Data Channel Units will be measured by each unit complete in place. 13. Payment. The work performed and materials furnished for Premium Subrate Data Multiplexer and Distribution Panel and measured as provided under "Measurement" will be paid for at the unit price bid for "Premium Subrate Data Multiplexer and Distribution Panel". This price shall be full compensation for all equipment, including Asynchronous Subrate Data Channel Units nested in the multiplexer, furnished, installed, made fully operational, and tested, including all cables and connectors, documentation, labor, materials, training, warranty, tools and equipment necessary to complete the work. The work performed and materials furnished for Asynchronous Subrate Data Channel Unit and measured as provided under "Measurement" will be paid for at the unit price bid for "Asynchronous Subrate Data Channel Unit," of the type specified. This price shall be full compensation for all equipment, cables and connectors; all documentation and testing and furnishing all labor, materials, training, and equipment necessary to complete the work
6 The work performed and materials furnished for Distribution Panel and measured as provided under "Measurement" will be paid for at the unit price bid for "Distribution Panel". This price shall be full compensation for all equipment, cables and connectors; all documentation and testing and furnishing all labor, materials, training, and equipment necessary to complete the work
SPECIAL SPECIFICATION 6146 Fiber Optic RS-232 Data Modem
2004 Specifications CSJ s 0508-07-027, 0177-06-064, 0271-04-067, 0389-13-049 SPECIAL SPECIFICATION 6146 Fiber Optic RS-232 Data Modem 1. Description. Furnish and install Fiber Optic RS-232 Data Modem (FO-MODEM)
More informationSPECIAL SPECIFICATION 6230 Fiber Optic RS-232 Data Modem
2004 Specifications CSJ 0924-06-258 SPECIAL SPECIFICATION 6230 Fiber Optic RS-232 Data Modem 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic RS- 232 Data Modem
More informationSPECIAL SPECIFICATION 6518 IP Video Codec
2004 Specifications CSJ 0922-33-098 SPECIAL SPECIFICATION 6518 IP Video Codec 1. Description. A. This Item governs the furnishing and installation of IP Video Codec in field location(s) as shown on the
More informationSPECIAL SPECIFICATION 6274 Microwave Vehicle Detection System
2004 Specifications CSJ 2374-01-153, etc. SPECIAL SPECIFICATION 6274 Microwave Vehicle Detection System 1. Description. Furnish and install the microwave vehicle detection (MVD) system as shown in the
More informationSPECIAL SPECIFICATION 1826 Field Ethernet Switch
1993 Specifications CSJ 0521-04-223 SPECIAL SPECIFICATION 1826 Field Ethernet Switch 1. Description. Furnish, install, and make fully operational a Field Ethernet Switch at designated locations as shown
More informationSPECIAL SPECIFICATION 8371 Field Terminal Server
2004 Specifications CSJ 0914-00-280 SPECIAL SPECIFICATION 8371 Field Terminal Server 1. Description. Furnish, install, and make fully operational a Field Terminal Server at designated locations as shown
More informationSPECIAL SPECIFICATION 1606 ISDN Compressed Video Equipment
1993 Specifications CSJ 0043-09-104, etc. SPECIAL SPECIFICATION 1606 ISDN Compressed Video Equipment 1. Description. This Item shall govern for the furnishing and installation of Integrated Services Digital
More informationSPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System
2004 Specifications CSJ 0902-48-433 SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System 1. Description. Furnish and install Digital Video Encoder/Decoder (Ethernet) System (DVE/DES)
More informationSPECIAL SPECIFICATION 8143 Wireless Ethernet Radio System
2004 Specifications CSJ 0002-01-080 SPECIAL SPECIFICATION 8143 Wireless Ethernet Radio System 1. Description. Furnish and install Wireless Ethernet Radio System (WERS) links for pointto-point applications,
More informationSPECIAL SPECIFICATION 6192 Hardened Ethernet Switch
2004 Specifications CSJ 2150-04-034 SPECIAL SPECIFICATION 6192 Hardened Ethernet Switch 1. Description. This Item governs the furnishing and installation of Hardened Ethernet Switch (HES) at designated
More informationSPECIAL SPECIFICATION 8885 Wireless Ethernet Radio (Backhaul) Link
2004 Specifications CSJ 0016-06-046, etc. SPECIAL SPECIFICATION 8885 Wireless Ethernet Radio (Backhaul) Link 1. Description. Furnish and install Wireless Ethernet Radio (WER) (Backhaul) Link in the 5.8
More informationSPECIAL SPECIFICATION 8939 Retrofit Existing Fiber Optic Dynamic Message Sign System to LED
2004 Specifications CSJ 0025-02-194, 0017-10-261, 0017-10-268 & 0017-10-271 SPECIAL SPECIFICATION 8939 Retrofit Existing Fiber Optic Dynamic Message Sign System to LED 1. Description. Retrofit existing
More informationSPECIAL SPECIFICATION 1672 ISDN Compressed Video Equipment
1993 Specifications CSJ s 0912-34-101 & 0027-08-108, etc. SPECIAL SPECIFICATION 1672 ISDN Compressed Video Equipment 1. Description. Furnish and install Integrated Services Digital Network (ISDN) Compressed
More informationSPECIAL SPECIFICATION 6027 Lane Control Signal Equipment
2004 Specifications SPECIAL SPECIFICATION 6027 Lane Control Signal Equipment 1. Description. Furnish and install Lane Control Signal (LCS) equipment. 2. Material. Provide new, corrosion resistant materials
More informationSPECIAL SPECIFICATION 1528 Add/Drop Multiplexor/Demultiplexor
1993 Specifications CSJ 3136-01-096 SPECIAL SPECIFICATION 1528 Add/Drop Multiplexor/Demultiplexor 1. Description. This Item shall govern for the furnishing and installation of a SONET Add/Drop Multiplexor/Demultiplexor
More informationSPECIAL SPECIFICATION 1838 Computer Room VoIP Gateway/Gatekeeper
1993 Specifications CSJ 0521-04-223 SPECIAL SPECIFICATION 1838 Computer Room VoIP Gateway/Gatekeeper 1. Description. Furnish, install, and make fully operational a Computer Room Voice-over- Internet Protocol
More information1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console
1993 Specifications CSJ 0598-01-057 1.0 Description SPECIAL SPECIFICATION ITEM 6398 Transportation Management Console This Item shall govern for the furnishing and installation of Transportation Management
More informationSPECIAL SPECIFICATION 6838 Wireless Ethernet Microwave Radio
2004 Specifications CSJ 1068-02-124 SPECIAL SPECIFICATION 6838 Wireless Ethernet Microwave Radio 1. Description. Furnish and install Wireless Ethernet Microwave Radio (WEMR) as shown on the plans, as detailed
More informationSPECIAL SPECIFICATION 8167 Ethernet Switch
2004 Specifications CSJ 0912-72-111 SPECIAL SPECIFICATION 8167 Ethernet Switch 1. Description. Furnish, install, integrate, and test Ethernet Switches (ES) and Hardened Ethernet Switches (HES) at designated
More informationSPECIAL SPECIFICATION 1252 System Control Unit Console
1993 Specifications CSJ 0924-06-147, etc. SPECIAL SPECIFICATION 1252 System Control Unit Console 1. Description. This Item shall govern for the furnishing and installation of system control unit (SCU)
More informationSPECIAL SPECIFICATION 6325 Wireless Ethernet Microwave Radio
2004 Specifications CSJ 0902-48-433 SPECIAL SPECIFICATION 6325 Wireless Ethernet Microwave Radio 1. Description. Furnish and install Wireless Ethernet Microwave Radio (WEMR) as shown on the plans, as detailed
More informationSPECIAL SPECIFICATION 6620 Add/Drop Multiplexor
2004 Specifications CSJ 2121-04-067, etc. SPECIAL SPECIFICATION 6620 Add/Drop Multiplexor 1. Description. This Item shall govern for the furnishing and installation of an Add/Drop Multiplexor/Demultiplexor
More informationSPECIAL SPECIFICATION 1986 CCTV Field Equipment
1993 Specifications CSJ 0027-12-086, etc. SPECIAL SPECIFICATION 1986 CCTV Field Equipment 1. Description. This Item shall govern for the furnishing and installation of Closed Circuit Television (CCTV)
More informationSPECIAL SPECIFICATION 6475 CCTV Field Equipment
2004 Specifications CSJ 0720-03-095 SPECIAL SPECIFICATION 6475 CCTV Field Equipment 1. Description. Furnish and install Closed Circuit Television (CCTV) field equipment in designated field locations and
More informationSPECIAL SPECIFICATION 6287 CCTV Field Equipment
2004 Specifications CSJ 0110-04-166 SPECIAL SPECIFICATION 6287 CCTV Field Equipment 1. Description. Furnish and install Closed Circuit Television (CCTV) field equipment in designated field locations and
More information1995 Metric CSJ's & SPECIAL SPECIFICATION ITEM CCTV Field Equipment
1995 Metric CSJ's 0177-07-098 & 0720-03-095 SPECIAL SPECIFICATION ITEM 6162 CCTV Field Equipment 1.0 Description. This Item shall govern for the furnishing and installation of Closed Circuit Television
More informationData channel ports and LAN channel ports will be referred to as channel ports when distinction between the two is not required.
DROP / INSERT NODES - Item No. CHANNEL PORTS - Item No. Special Provision No. 683S19 September 2007 1. SCOPE This Special Provision covers the requirements for the installation and testing of Field Drop
More information1993 Specifications CSJ SPECIAL SPECIFICATION ITEM 6392 CCTV FIELD EQUIPMENT
1993 Specifications CSJ 0364-01-095 SPECIAL SPECIFICATION ITEM 6392 CCTV FIELD EQUIPMENT 1.0 Description. This Item shall govern for the furnishing and installation of closed circuit television (CCTV)
More informationSPECIAL SPECIFICATION 6025 CCTV Field Equipment
2004 Specifications SPECIAL SPECIFICATION 6025 CCTV Field Equipment 1. Description. Furnish and install closed circuit television (CCTV) field equipment. 2. Materials. Provide new, corrosion resistant
More informationSpecial Specification 6168 Add/Drop Multiplexor
Special Specification Add/Drop Multiplexor 1. DESCRIPTION 2. MATERIALS Furnish and install an Add/Drop Multiplexor/Demultiplexor (ADM). The ADM includes voice, data, and video in a single integrated unit.
More informationMODIFIED SPECIAL PROVISION APPROVAL REQUEST (REV ) Date: 11/02/2015 District: 5 Type: Project Specific
MODIFIED SPECIAL PROVISION APPROVAL REQUEST (REV 11-02-15) Date: 11/02/2015 District: 5 Type: Project Specific Letting Month: March 2016 FPID Number: 435443-2-52-01 Requested by: Mark Herring Office/Phone:
More informationMaster Hub Ethernet Switch (MHES)
TECHNICAL SPECIAL PROVISION FOR Master Hub Ethernet Switch (MHES) FINANCIAL PROJECT NO.: 428213-2-52-02 MARION COUNTY The official record of this Technical Special Provision is the electronic file signed
More informationSTATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625
STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 METRIC SPECIFICATIONS FOR VME BUS COMPUTER (FIELD TERMINAL VME BUS PROCESSOR ASSEMBLY) N.J. Specification No. Effective Date:
More informationSPECIAL SPECIFICATION 1864 Pole Mounted Cabinet
1993 Specifications CSJ s 0924-06-221,etc. & 0924-06-223 SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1. Description. This specification describes the minimum acceptable requirements for a weatherproof
More informationSPECIAL SPECIFICATION 6373 Wireless Radio Traffic Management Sites
2004 Specifications CSJ 0521-04-187 SPECIAL SPECIFICATION 6373 Wireless Radio Traffic Management Sites 1. Description. Furnish, install, and make fully operational with the TransGuide Traffic Management
More informationSPECIAL SPECIFICATION 1303 Lifelink
1993 Specifications CSJ 0024-08-110 SPECIAL SPECIFICATION 1303 Lifelink 1. Description. This Item shall govern for the furnishing and installation of LifeLink equipment in Fiber Hubs (existing and proposed)
More informationSPECIAL SPECIFICATION 1332 Variable Message Sign Cabinet and Controller Replacement
1993 Specifications CSJ 0073-08-145, etc. SPECIAL SPECIFICATION 1332 Variable Message Sign Cabinet and Controller Replacement 1. Description. This Item shall govern for the furnishing and installation
More information1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM
1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL
More informationA. The high quality, lightweight, varifocal manual iris lens shall be suitable for applications where scene and lighting requirements are consistent.
Section 00000 SECURITY ACCESS AND SURVEILLANCE ADEMCO VIDEO VARIFOCAL MANUAL IRIS LENS PART 1 GENERAL 1.01 SUMMARY The intent of this document is to specify the minimum criteria for the design, supply,
More informationDATA CONNECT ENTERPRISE
DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM ITS:CLC 1 of 6 APPR:LWB:DBP:07-31-13 FHWA:APPR:09-23-13 a. Description. This work consists of one or more
More information* * Agilent Power Distribution Unit (PDU) Installation Guide
Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The
More informationUSER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 1018 High Speed Short Range Modem w/ Extra Controls Part# 07M1018-B Doc# 013021UB Revised 11/3/95 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION
More informationSPECIAL SPECIFICATION 6900 LED Lane Control System
2004 Specifications CSJ 0073-08-162, 0017-10-269, 0017-10-268 & 0017-10-271 SPECIAL SPECIFICATION 6900 LED Lane Control System 1. Description. Furnish and install FTM (Freeway Traffic Management) LED Lane
More informationUSER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters
USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0
More informationSECTION ELECTRIC METERING
SECTION 26 27 13 ELECTRIC METERING SPEC WRITER NOTES: Use this section only for NCA projects Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable
More informationSpecial Specification 6082 LED Lane Control System
Special Specification LED Lane Control System 1. DESCRIPTION 2. MATERIALS Furnish and install FTM (Freeway Traffic Management) LED Lane Control Signal (LCS) Field Equipment and all necessary associated
More informationSPECIAL SPECIFICATION 1859 Programmable Logic Controller
1993 Specifications CSJ s 0924-06-221, etc. & 0924-06-223 SPECIAL SPECIFICATION 1859 Programmable Logic Controller 1. Description. This Item shall govern for the furnishing and installation of a programmable
More informationCVH Slot Media Converter Chassis Quick Installation Guide
CVH-2000 14-Slot Media Converter Chassis Quick Installation Guide Ver. 1.2-1305 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. PACKAGE CONTENTS... 1 2. HARDWARE DESCRIPTION... 2 REAL PANEL...
More informationCOOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN
Voltage Regulators MN225074EN Effective March 2017 Supersedes January 2012 (S225-40-7) RS-485 digital communications accessory board installation and operation instructions COOPER POWER SERIES DISCLAIMER
More informationCanoga Traffic Sensing System
Canoga Traffic Sensing System Canoga 942E and 944E Traffic Monitoring Cards Canoga Traffic Monitoring Card Configuration Software (TMC-CS) Matched Components of the Canoga Traffic Sensing System October
More information*REQUIRED* 169 Main Street 700 Plaza Middlesex Middletown, CT T: F:
ADDENDUM COVER & RECEIPT CONFIRMATION SHEET 169 Main Street 700 Plaza Middlesex Middletown, CT 06457 T: 860-343-8297 F: 860-343-9504 www.wright-pierce.com DATE: 9/6/16 ADDENDUM CONSISTS OF (Including this
More informationSpecial Provision No. 683S27 June 2017
GATEWAY ROUTERS - Item No. Special Provision No. 683S27 June 2017 1. SCOPE This Special Provision covers the requirements for the installation of Gateway Routers with integrated digital subscriber line
More informationModel 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.
Page 1 of 5 Model 282 Total Interface Isolation Module Reference Manual 0315-0169 Rev. A Print 08.01.01 1.0 General Description Table of Contents 2.0 Specifications 2.1 Interface 2.2 Connectors 2.3 Isolation
More informationINSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-6B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationF2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual
F2238A and F2245A Fiber-Optic EIA-530/MIL-STD-188-114 Modem Technical Manual Revision C October 2013 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com PROPRIETARY DATA All data
More informationPAGE 818. The following new Section is added after Section 678. SECTION 7684 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES
684 NETWORK DEVICES. (REV 5-1518-13) (FA 7-30-13) (1-14) PAGE 818. The following new Section is added after Section 678. SECTION 7684 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES 7684-1 Managed Field
More informationINSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-5B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationINSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-4B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13
More informationSpecial Specification 2342 Environmentally Controlled Radio Tower Cabinet
2004 Specifications CSJ 0912-00-488 Special Specification 2342 Environmentally Controlled Radio Tower Cabinet 1. Description. Furnish, install, and test Environmentally Controlled Radio Tower Cabinet.
More informationSIU-218 and SIU-2218
SIU-218 and SIU-2218 Serial Interface Unit THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE SIU-218 AND SIU-2218 SERIES SERIAL INTERFACE UNIT REVISION: OCTOBER 2013 pn 888-0218-001 THE SIU-218 AND SIU-2218
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM ITS:CLC 1 of 5 APPR:JVG:DBP:06-29-17 FHWA:APPR:08-02-17 a. Description. This work consists of one or more
More informationFVT Slot Media Converter Chassis w/ Redundant Power User Manual
FVT-4000 10-Slot Media Converter Chassis w/ Redundant Power User Manual Ver. 1.00-0609 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. PACKAGE CONTENTS... 2 2. HARDWARE DESCRIPTION... 3
More informationINSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-7B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationSUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA)
TECHNICAL SPECIAL PROVISION FOR SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA) FINANCIAL PROJECT NO.: 428213-2-52-02 MARION COUNTY The official record of this Technical Special Provision is the
More informationUSB 2.0 RG2324/ Port USB 2.0 Fiber Optic Extender System. User Guide
USB 2.0 RG2324/2344 4-Port USB 2.0 Fiber Optic Extender System User Guide Thank you for purchasing the USB 2.0 RG2324 or RG2344. This document applies to the following part numbers: Please read this guide
More informationOPERATING AND SERVICE MANUAL. Universal Interface Device 47
OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 2012 SAFETY NOTICE Universal Interface Device 47 (UID46) connects
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR TRAVEL TIME SYSTEM. UNIV:SRP 1 of 6 ITS:APPR:CLC:DBP:
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR TRAVEL TIME SYSTEM UNIV:SRP 1 of 6 ITS:APPR:CLC:DBP:02-02-12 a. Description. This work consists of furnishing, installing, integrating, and testing
More informationSpecial Specification 6073 Model 170E Series Traffic Signal Controller, Cabinets and Related Equipment
Special Specification 6073 Model 170E Series Traffic Signal Controller, Cabinets and Related Equipment 1. DESCRIPTION 2. MATERIALS Furnish traffic signal control equipment. Furnish materials conforming
More informationDMX512-A 2.10 HUB. User Guide
DMX512-A 2.10 HUB User Guide DMX512-A 2.10 HUB User Guide Document hub2.10_web_man_uk Copyright 2003-2008. All rights reserved. No part of this documentation may be reproduced or transmitted in any form
More informationUSB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide
USB 3-2-1 Raven 3124 4-Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 Raven 3124. Please read this guide thoroughly. This document applies
More informationMODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439
MODEL DSU-56 56 Kbps Rack Mount CSU/DSU OPERATOR S MANUAL 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439 TEL: 775-345-8000 FAX: 775-345-8010 E-MAIL: SUPPORT @S.NET DSU-56 Rack Mount TABLE OF CONTENTS
More informationSPECIAL PROVISION Instructions to Bidders
2004 Specifications SPECIAL PROVISION 002---001 Instructions to Bidders For this project, Item 002, Instructions to Bidders, of the Standard Specifications, is hereby amended with respect to the clauses
More information4100/ VDC Converter Installation Instructions
4100/4120-0156 8 VDC Converter Installation Instructions Introduction This publication describes the installation procedure for the 8 VDC Converter. Related Documentation Field Wiring Diagram for 4100
More informationModel 4001A Modular System Bin Operating and Service Manual
Model 4001A Modular System Bin Operating and Service Manual Printed in U.S.A. ORTEC Part No. 733740 0704 Manual Revision D $GYDQFHG0HDVXUHPHQW7HFKQRORJ\,QF a/k/a/ ORTEC, a subsidiary of AMETEK, Inc. WARRANTY
More informationSTATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625
September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The
More informationDMX512-A 1.5 HUB. User Guide
DMX512-A 1.5 HUB User Guide DMX512-A 1.5 HUB User Guide Document hub1.5_web_man_uk Copyright 2003-2008. All rights reserved. No part of this documentation may be reproduced or transmitted in any form or
More informationCOOPER POWER SERIES. Fiber-optic/RS-232 communications module installation and operation instructions. Voltage Regulators MN225020EN
Voltage Regulators MN225020EN Effective May 2015 Supersedes S225-40-4 November 2011 COOPER POWER Fiber-optic/RS-232 communications module installation and operation instructions SERIES DISCLAIMER OF WARRANTIES
More informationUSER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter
USER MANUAL MODEL 505M-CHC Surge Protected DB-25 to RJ-45 Modular Adapter C E R T I F I E D An ISO-9001 Certified Company Part# 07M505MCHC-A Doc# 074281U, Rev. B Revised 1/21/08 SALES OFFICE (301) 975-1000
More informationUSER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter
USER MANUAL MODEL 011 High Speed Asynchronous to Synchronous Converter Part# 07M011-A Doc# 0601UA Revised 03/16/94 SALES ICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY
More informationOPERATING AND SERVICE MANUAL. Universal Interface Device 47
OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 202 SAFETY NOTICE Universal Interface Device 47 (UID47) connects two
More informationLiebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System
Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe
More information1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.
SECTION 26 04 75 - SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Applicable provisions of the General Conditions, Supplementary General Conditions and Special Conditions shall govern work performed
More informationMF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide
1 INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER Installation Guide October 2008 VERSITRON, Inc. 83C Albe Drive Newark, DE 19702 800-537-2296 2 PROPRIETARY DATA All data in this manual is proprietary
More informationSECTION ( ) LIGHTING CONTROL PANELBOARD
(26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting
More informationUSER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter
USER MANUAL MODEL 2030 Bidirectional (IEEE-1284) Line Driver/Converter An ISO-9001 Certified Company Part # 07M2030-B Doc. #102121U, Rev. C Revised 1/22/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationTOWN OF MANCHESTER GENERAL SERVICES DEPARTMENT 494 MAIN STREET P.O. BOX 191 MANCHESTER, CONNECTICUT
TOWN OF MANCHESTER GENERAL SERVICES DEPARTMENT 494 MAIN STREET P.O. BOX 191 MANCHESTER, CONNECTICUT 06045-0191 TRAFFIC SIGNAL INSTALLATIONS MIDDLE TURNPIKE EAST AT SUMMIT STREET MIDDLE TURNPIKE EAST AT
More informationM-series Intrinsically Safe I/O
DeltaV Distributed Control System Product Data Sheet M-series Intrinsically Safe I/O Features full system modularity Reduces system footprint Decreases installation time and expense Plug-and-play installation
More informationUSER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem
USER MANUAL MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem An ISO-9001 Certified Company Part #07M1003-B Doc. #050021UB Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL
More informationMeter Enclosure and Equipment Standards
Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable
More informationS7999D SOLA Operator Interface Display
S7999D Operator Interface Display INSTALLATION INSTRUCTIONS APPLICATION The S7999D is microprocessor-based color touch-screen Operator Interface (OI) display that provides an operator interface for monitoring
More informationAn ISO-9001 Certified Company
USER MANUAL MODEL 1002 and 1002S Asynchronous 2-Wire / Coax Short Range Modem An ISO-9001 Certified Company Part #07M1002-C Doc. #050011UC Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationSPECIAL PROVISION Scope of Work
2004 Specifications CSJ 0914-00-301 & 0914-00-314 SPECIAL PROVISION 004---018 Scope of Work For this project, Item 004, Scope of Work, of the Standard Specifications, is hereby amended with respect to
More informationSECTION N -- ELECTROSTATIC DISCHARGE (ESD)
INSTALLATION REQUIREMENTS AT&T January, 2012 Section N, ATT-TP-76300 Revised NA SECTION N -- ELECTROSTATIC DISCHARGE (ESD) CONTENTS PAGE 1. GENERAL... N-1 1.1. Introduction... N-1 1.2. General Requirements...
More informationInstruction Manual RT-91685SL RR-91685SL Sixteen Channel Video Multiplexer With Two Bi-directional Data Channels
Instruction Manual RT-91685SL RR-91685SL Sixteen Channel Video Multiplexer With Two Bi-directional Data Channels Copyright 2007, American Fibertek, Inc. 0501JD Table of Contents Functional Description...3
More informationClick Desktop Kit. Click Desktop Kit
Click Desktop Kit Click Desktop Kit The Click Desktop Kit is a desktop-mounted set that gives you the building blocks necessary to work with your Click modules at your computer, whether you re testing
More information1995 Metric CSJ 's & SPECIAL PROVISION ITEM 4. Scope of Work
1995 Metric CSJ 's 0015-13-235 & 3136-01-098 SPECIAL PROVISION TO ITEM 4 Scope of Work For this project, Item 4, "Scope of Work", of the Standard Specifications, is hereby amended with respect to the clauses
More informationF280XD Fiber-Optic RS-232 Modem Technical Manual
F280XD Fiber-Optic RS-232 Modem Technical Manual Revision B August 2012 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since 1958 PROPRIETARY DATA
More informationOverview of the Cisco 2524 and Cisco 2525 Routers
CHAPTER 1 Overview of the Cisco 2524 and Cisco 2525 Routers The Cisco 2524 and Cisco 2525 routers provide LAN and WAN access in a low-cost modular router platform that can grow with your internetworking