MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

Size: px
Start display at page:

Download "MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)"

Transcription

1 MODEL: MDST Lightning Surge Protectors for Electronics Equipment M-RESTER LIGHTNING SURGE PROTECTOR FOR STANDARD SIGNAL LINE (ultra-slim) Functions & Features High discharge current capacity 0 ka ( / 0μs), 1 ka (10 / 30 μs) Ultra-thin -mm-wide module can be mounted in high density Excellent protection employing multi-stage SPD circuits DIN rail mounting and grounding terminal provided CE marking (.) 9 (3.4) 9 (3.6) mm (inch) MODEL: MDST[1][][3][4] ORDERING INFORMATION Code number: MDST-[1][][3][4] Specify a code from below for each [1] through [4]. (e.g. MDST-4FF00) For the safety approval code, specify the product s destination country using Ordering Information Sheet (No. ESU-0). [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable) [4] SAFETY APPROVAL 0: None : CENELEC intrinsic safety (ATEX) RELATED PRODUCTS Loop disconnect fuse (model: MDF) GENERAL SPECIFICATIONS Construction: Slim-sized front terminal structure Degree of protection: IP0 Connection: Euro terminal block (torque 0.3 N m) Applicable wire size: 0.. mm : DIN Rail Housing material: Flame-resistant resin (black) Loop disconnect fuse: Current rating 0 ma (Separates the protected device from the power source when the former fails in the shortcircuit mode.) INSTALLATION Operating temperature: - to C (-13 to 1 F) (See Safety Parameters for use in a hazardous location.) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: DIN Rail (TH3-., 1-mm-thick) Oxide film on the surface of an aluminium rail may lower the electric conductivity between this module and the ground. Use a steel or copper rail. Weight: 0 g (. oz) [1] NOMINAL VOLTAGE 4: 4 V DC 60: 60 V DC [] SHIELD TERMINAL (line / earth) FF: / FG: / GF: / GG: / MDST SPECIFICATIONS ES-0 Rev.6 Page 1/6

2 MODEL: MDST PERFORMANCE MODEL NO. NOMINAL VOLTAGE MDST-4 MDST-60 SHLD TERMINAL FF FG GF GG FF FG GF GG Max. continuous Line to Line 30V 0V operating voltage Line to Earth ±160V 30V ±160V 0V (Uc) Line to SHLD ±160V 30V ±160V 0V SHLD to Earth ±160V short ±160V short ±160V short ±160V short Voltage protection Line to Line 60V 11V level (Up) Line to Earth ±00V ±60V ±00V (1. / 0 µs) Line to SHLD ±100V ±00V ±60V ±100V ±00V ±11V SHLD to Earth ±00V short ±00V short ±00V short ±00V short Leakage current Line to Line µa Other sections µa µa Response time Line to Line 4 nsec. 4 nsec. Max. discharge current (Imax) Nominal current (IN) Other sections 0 nsec. 0 nsec. 0kA ( / 0 µs), 1.0kA (10 / 30 µs) 0mA Internal series Without fuse 4.Ω ±10% per line 10Ω ±10% per line resistance With fuse.ω ±10% per line 1.Ω ±10% per line STANDARDS & APPROVALS CE conformity: ATEX Directive (94/9/EC) Ex ia EN : 00 Category 1G EN : 00 EMC Directive (004/10/EC) EMI EN : 00 EMS EN : 00 Safety approval: CENELEC: Intrinsic safety (ATEX) II 1G, Ex ia IIC; T4 and T EN : 006 EN : 00 EN : 00 Surge protection: IEC : 000 (Categories C1, C, D1) SAFETY PARAMETERS CENELEC / ATEX IS DATA MDST-4 MDST-60 Ui (Vmax) 3V 60V Ii (Imax) any any Ci 10 nf nf Li 0 µh 0 µh Temp. Class Range Parameter - to 40 C 1.3W Pi T4 - to 60 C 1.W - to 0 C 1.0W T - to 40 C 1.0W MDST SPECIFICATIONS ES-0 Rev.6 Page /6

3 MODEL: MDST DESCRIPTIONS SELECTING SHIELD TERMINAL TYPE The surge protector has a dedicated shield terminal effective for easy shield wiring and surge protection. Review the shield method (grounding, non-grounding, connecting to SG, etc.) required by the protected device or system. There is no electrical effect to the shield by installing the surge protector, but an appropriate shield terminal type must be selected to suit user applications. Refer to the flow chart below to choose. Cable With Without to Signal Isolated to Signal Not Isolated Signal to Earth Isolated Signal to Earth Not Isolated Not Grounded Grounded Not Grounded Grounded FF FG GF GG FF GG SELECTING LOOP DISCONNECT FUSE Specify Loop disconnect fuse type when multiple transmitters are connected to single power bus. Loop disconnect fuse is used to separate a transmitter loop from the power bus when it fails in the shortcircuit mode. 4 0mA Field-mount Transmitter Surge Protector MDST 4 1 DC Power Supply (model: MD6x) 0Ω ADAPTOR Power Bus To other 4 0mA loops MDST SPECIFICATIONS ES-0 Rev.6 Page 3/6

4 MODEL: MDST CONNECTION EXAMPLES 4 0mA Field-mount Transmitter Surge Protector Current Loop Supply 4 1 (model: MD6x) *4 ADAPTOR *1 * *3 Crossover Wire FG *1. Oxide film on the surface of an aluminium rail may lower the electric conductivity between this module and the ground. Use a steel or copper rail. *. Be sure to ground the DIN rail. Recommended grounding resistance 100Ω *3. Cross-wire between the DIN rail and the metal housing of the protected device to equalize the earth potential. Ground only the surge protector when the protected device has no ground terminal. *4. wiring method is an example. Proceed according to the system requirements. EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) M3 EURO TERMINAL WIRE INSERTION ANGLE: approx LOOP DISCONNECT FUSE (option) 4 6 ADAPTOR (3 mm wide) 9 (3.4) (.4) 1.9 (.0) (.) 9 (3.6) [1. (.0)] MDST SPECIFICATIONS ES-0 Rev.6 Page 4/6

5 MODEL: MDST SCHEMATIC CIRCUITRY SHIELD TERMINAL MODEL NO. SCHEMATIC CIRCUITRY APPLICATIONS MDST-xFF0x MDST-xFF1x 4 1 Standard type To protect a device having isolation between Signal and Earth. When SHLD should be floating against the earth. (single-end grounding) ADAPTOR MDST-xFG0x MDST-xFG1x 4 1 To protect a device having isolation between Signal and Earth. When SHLD should be grounded. (single- or bothend grounding) ADAPTOR MDST-xGF0x MDST-xGF1x 4 1 To protect a device having isolation between Signal and Earth. When SHLD wire should be connected to SG terminal of the protected device. (SHLD is not grounded to the earth.) ADAPTOR MDST-xGG0x MDST-xGG1x 4 1 To protect a device which does not have a good dielectric strength between Signal and Earth. ADAPTOR Sections enclosed with broken line may differ depending upon the models; without option, fuse circuit is shorted. MDST SPECIFICATIONS ES-0 Rev.6 Page /6

6 MODEL: MDST Specifications are subject to change without notice. MDST SPECIFICATIONS ES-0 Rev.6 Page 6/6

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER MODEL: MDTC Lightning Surge Protectors for Electronics Equipment M-RESTER LIGHTNING SURGE PROTECTOR FOR THERMOCOUPLE USE (ultra-slim) Functions & Features High discharge current capacity 0 ka ( / 0 μs),

More information

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTNIN SURE PROTECTOR FOR ETHERNET (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) Functions & Features Designed specifically for Ethernet network

More information

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTNIN SURE PROTECTOR FOR ETHERNET (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) Functions & Features Designed specifically for Ethernet network

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

MODEL: 43AL1. Digital Panel Meters 43 Series

MODEL: 43AL1. Digital Panel Meters 43 Series Digital Panel Meters 43 Series LOOP POWERED DIGITAL PANEL METER (process meter) Functions & Features Loop powered -1999 to 9999 compact digital meter Scaling function Screwless spring terminal 24 (.94)

More information

MODEL: MAKF. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MAKF. Lightning Surge Protectors for Electronics Equipment M-RESTER MODEL: Lightning Surge Protectors for Electronics Equipment M-RESTER OE-PORT SURE PROTECTOR FOR POWER SUPPLY USE Functions & Features Designed to protect electronics equipment from induced lightning surges

More information

MODEL: 47LYV. Digital Panel Meters 47 Series

MODEL: 47LYV. Digital Panel Meters 47 Series Digital Panel Meters 47 Series DC INPUT DIGITAL PANEL METER (4 1/2 digit, process meter, LED display type) Functions & Features 4 ½ digit DC input digital panel meter 1/8 DIN size Moving average function

More information

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC MODEL: M1EX 2 Channel Super-mini Signal Conditioners with Display M1E Series SIGNAL TRANSMITTER (2 channels, PC programmable) Functions & Features Converts DC input from a sensor into a standard process

More information

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders R1M Series PC RECORDER (contact output, 32 points) Functions & Features Industrial recorder on PC 32-point open collector outputs Easy system expansion via Modbus RTU Recorded data exportable

More information

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: R2K-1 SEN TRONIC AG. R2K Series 1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission

More information

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC 2 Channel Super-mini Signal Conditioners with Display M1E Series POTENTIOMETER TRANSMITTER (2 channels, PC programmable) Functions & Features Potentiometer s zero/span points can be captured by onsite

More information

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to

More information

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series MODEL: MEXM Super-mini Signal Conditioners with Mini-M ME Series POTENTIOMETER TRANSMITTER (PC programmable) Functions & Features Provides a DC output proportional to a potentiometer or slidewire position

More information

MODEL: 40DN. Digital Panel Meters 40 Series

MODEL: 40DN. Digital Panel Meters 40 Series Digital Panel Meters 40 Series LOOP POWERED DIGITAL PANEL METER (4 digits, process meter) Functions & Features 4 digit (±9999) loop powered panel meter No external power source needed Scaling function

More information

NEW NEW NEW NEW NEW NEW Electrical specification ESP SL06 ESP SL15 ESP SL30 ESP SL50 ESP SL110 ESP SL TN

NEW NEW NEW NEW NEW NEW Electrical specification ESP SL06 ESP SL15 ESP SL30 ESP SL50 ESP SL110 ESP SL TN Line Current rating In-line resistance Nottingham, NG EB, UK 0V 6.7V 750mA.0Ω 0kA 6V ESP SL Series Combined Category D, C, B tested protector (to BS EN 66) suitable for twisted pair signalling applications

More information

MODEL: GR8-EM. Communication Adaptor GR8 Series

MODEL: GR8-EM. Communication Adaptor GR8 Series Communication Adaptor GR8 Series Ethernet/RS-485 Adaptor (Modbus use) Functions & Features Bidirectional protocol converter for Modbus/TCP (Ethernet) and Modbus RTU (RS-485) Fast response time thanks to

More information

MODEL: MAT3. [2] ALARM OUTPUT A: With Y: Without. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MAT3. [2] ALARM OUTPUT A: With Y: Without. Lightning Surge Protectors for Electronics Equipment M-RESTER MODEL: MAT Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTI SURE PROTETOR FOR THREE-PHASE POWER SUPPLY Functions & Features onnected in parallel between the power and earth lines regardless

More information

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: R1M-GH. PC Recorders R1M Series PC Recorders Series PC RECORDER (thermocouple or DC input, 16 points) Functions & Features Industrial recorder on PC 16-point thermocouple or DC inputs Easy system expansion via Modbus RTU Recorded data

More information

PT 3-PB-ST. Extract from the online catalog. Order No.:

PT 3-PB-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode

More information

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

PT 2X2-24DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 2X2-24DC-ST Order No.: 2838228 The illustration shows version PT 2x2-5DC-ST Protective plug PT with protective circuit for two 2-core floating signal circuits. Nominal

More information

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

TT-2-PE- 24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-2-PE- 24DC Order No.: 2838186 Modular terminal block with three-stage surge protection for a floating double conductor, separate ground connection, nominal voltage: 24

More information

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 2X2-HF-24 DC-ST Order No.: 2839729 The illustration shows the version PT 2x2-HF-12 DC-ST Protective plug PT with HF protective circuit for two 2-core floating signal

More information

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage

More information

MODEL: 43DV2. Digital Panel Meters 43 Series

MODEL: 43DV2. Digital Panel Meters 43 Series Digital Panel Meters 43 Series DC INPUT DIGITA PANE METER (process meter) Functions & Features -1999 to +9999 digital panel meter Scaling & old functions available Screwless spring terminal (Input range:

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08) MODEL: R-NE Remote I/O R Series ETHERNET INTERFACE MODULE (Modbus/TCP) 7. (.8) 9 (.9) (.) mm (inch) MODEL: R-NE-[][] ORDERING INFORMATION Code number: R-NE-[][] Specify a code from below for each [] and

More information

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

TT-2-PE-M-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-2-PE-M-24DC Order No.: 2920641 Modular terminal block with two-stage surge protection for one operated floating double conductor, disconnect knife on both signal paths,

More information

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system

More information

MANUAL Surge Protectors

MANUAL Surge Protectors PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 5-HF- 5 DC-ST Order No.: 2838762 The illustration shows variant PT 5-HF-12 DC-ST Protective plug PT with HF protective circuit for 4 signal wires. Nominal voltage: 5

More information

General Specifications

General Specifications General Specifications LN90 Interface Adapter GENERAL This General Specification (GS) describes the specification for Interface Adapter. This product is a RS-485 signal relay and power supply for the Field

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series Digital Panel Meters 40 Series RTD INPUT DIGITA PANE METER (4 digits, process meter) Functions & Features 4 digit (±9999) panel meter functions igh visible, 0.8" (20.3mm) high and bright ED 48 (1.89) mm

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

Lightning Surge Protectors

Lightning Surge Protectors Protecting sensor, signal, power and communication lines Designed for the rugged industrial environment. Products range from the standard factory floor signals such as 4 20mA, thermocouple, RTD and strain

More information

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3] Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) 44 (5.67) 7 (.83) * mm (inch) *Selectable with option code /4: 400 mm /6: 600 mm Language blank: Japanese /E: English

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS 2MOPP Medical FEATURES Universal Input Range Operating Temperature Range: -25º to 80ºC (with derating) Compact Package: 2.00 3.00 1.16

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure

More information

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.: Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus Safety Instructions PMC71, PMP71, PMP75 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex ia IIC T6 Ga/Gb IECEx KEM06.0011 0 XA00696P-D Safety instructions for electrical apparatus for explosion-hazardous

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL RM-GH BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Surge Protection Devices Ex9UE2

Surge Protection Devices Ex9UE2 Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,

More information

Slot Resistance Thermometers

Slot Resistance Thermometers Slot Resistance Thermometers www.ephy-mess.de Contents 1. Slot Resistance Thermometer (NWT) 2 bifilar and chip type design 1.1 EPHY-MESS NWT delivery program list 2 1.2 Slot resistance thermometer with

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS REPETER (SIN-NET, M-us use) MODEL DL MODEL & SUFFIX CODE SELECTION MODEL CLE & PORT TYPE : Twisted-pair cable, ports : Fiber optics (PCF), ports Twisted-pair cable, port 5 : Fiber optics (I-50 nm), port

More information

MACX MCR-EX-SD LP(-SP)

MACX MCR-EX-SD LP(-SP) Intrinsically safe solenoid driver for Group IIC gases, loop-powered, current limit 48 ma INTERFACE Data sheet 103468_en_01 PHOENIX CONTACT - 08/2008 1 Description The solenoid driver MACX MCR-EX-SD-24-48-LP(-SP)

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1. Ethernet Remote I/O F&eIT N Series Isolated Digital / DIO-1616LN-FIT * Specifications, color and design of the products are subject to change without notice. This product is an isolated digital input and

More information

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2 Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering

More information

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information Separating and protective instruments Separating and protective instruments VEGATRENN 149AEx Separator type KFDO Barrier type 9001 Product Information Content Content 1 Product description..........................................................................

More information

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5 EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on

More information

SIMATIC Distributed I/O Product information for the ET 200iSP Operating Instructions (A5E ) 01/2010

SIMATIC Distributed I/O Product information for the ET 200iSP Operating Instructions (A5E ) 01/2010 SIMATIC Distributed I/O Product information for the ET 200iSP Operating Instructions (A5E00247483-04) 01/2010 Product Information Order number Type Order number 4 DO DC23.1V/20mA SHUT DOWN "H" 6ES7132-7RD01-0AB0

More information

Surge Protective Device

Surge Protective Device Surge Protective Device LED Light / Machine protection SPD Class 2 LT-C34G801W General Information LT-C and LT-HC series Surge Protective Devices are for protection of indirect lightning. They are designed

More information

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O DATASHEET NI REM-11115 Analog Output Module for Remote I/O Four voltage output ranges to choose from (0 V to 10V, ±10V, 0 V to 5 V, and ±5V) Two current output ranges to choose from (0 ma to 20mA, 4 ma

More information

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. Tower Light Series CC-Link TOWER LIGHT (0 mm dia., layers) Functions & Features Lighting, blinking and buzzing are controllable with PLC. Bi-color lighting available in fourth layer Separable tension clamp

More information

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1 Medical Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger PV Railway PART NUMBER STRUCTURE M A F 150 U S 12 B - Application Package Dimension Output Input Output Output Protection

More information

LED Driver DC-String

LED Driver DC-String Driver LCU 48V 15W DC-STR FO lp Fixed output Product description Fixed output constant voltage built-in LED Driver Compatible with other components Max. output power 15 W Up to 93 % efficiency Nominal

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

Surge Protection for Surveillance Systems

Surge Protection for Surveillance Systems Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:

More information

Surge & Filter Protection Addressing your industrial power quality needs.

Surge & Filter Protection Addressing your industrial power quality needs. Surge & Filter Protection Addressing your industrial power quality needs. BULLETIN 983 INTRODUCING SURGE & FILTER PROTECTION SURGE & FILTER PROTECTION Rockwell Automation is pleased to introduce the Bulletin

More information

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description Block device couplers Data sheet 3177_en_A 1 Description PHOENX CONTACT 2015-01-20 2 Features The and block couplers provide an interface between the fieldbus trunk cable and field devices on Foundation

More information

TEPI11 P/I signal converter

TEPI11 P/I signal converter Contents Data Sheet 10/18-0.15-EN Rev. A TEPI11 P/I signal converter Air pressure in current DMS sensor for gauge pressure Compact design Small dimensions, low weight Can be installed in any orientation

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

M-series Intrinsically Safe I/O

M-series Intrinsically Safe I/O DeltaV Distributed Control System Product Data Sheet M-series Intrinsically Safe I/O Features full system modularity Reduces system footprint Decreases installation time and expense Plug-and-play installation

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Switch Mode Power Supply S8VT 120/240/480/960 W Models Switch Mode Power Supply 120/240/480/960 W Models Natural Cooling Three-phase Power Supply Range from 5A up to 40A with Output Voltage of 24VDC 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output

More information

Surge protection for MCR technology

Surge protection for MCR technology PHOENIX CONTACT Main range Features 6 Selection guide D rail modules MCR-PLUGTRAB 90 LETRAB 0 Interfaces in MCR applications are far more sensitive to surge voltages than power supply systems. Arresters

More information

LED Driver Linear / area dimming

LED Driver Linear / area dimming Driver LC 35W 7mA -1V UNV sl ADV ADVANCED series Product description Built-in constant current For dry and damp location Max. output power 35 W Up to 85 % efficiency Nominal life-time up to 5, h For luminaires

More information

16-Channel Digital Input Termination Card 24Vdc

16-Channel Digital Input Termination Card 24Vdc TDI16BIA 16-Channel Digital Input Termination Card 24Vdc (TDI16BIA) Issue 3 October 2005 INTRODUCTION PURPOSE The TDI16BIA16-channel digital input termination card acts as an interface between the digital

More information

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend Three-phase Input Switch Mode Power Supply S8VT DIN-rail mounting, Power Supply with a range of 5 A to 40 A output current 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output Higher stability, lower

More information

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W Selection Guide Selection Guide PS5R Slim Line PS5R PS3L Operator Interfaces Communication & Networking PLCs NEW Models Appearance Automation Software Page 107 113 118 Housing Plastic Metal Mounting DIN

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If

More information

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Input Voltage (/Hz) Input Voltage (VDC) Max wattage (W) Voltage (V) Current max (A) Maximum capacitive load (µf)

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage

More information

MODEL: 40DV SEN TRONIC AG. Digital Panel Meters 40 Series

MODEL: 40DV SEN TRONIC AG. Digital Panel Meters 40 Series Digital Panel Meters 40 Series DC INPUT DIGIT PNE METER (4 digits, process meter) Functions & Features 4 digit (±9999) panel meter Scaling and functions igh visible, 0.8" (20.3mm) high and bright ED 48

More information

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications. Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers

More information

Data & signal protection ESP D & TN Series

Data & signal protection ESP D & TN Series ESP D & TN Series Combined Category D, C, B tested protector (to BS EN 66) suitable for most twisted pair signalling applications. Available for working voltages of up to 6, 5, 0, 50 and 0 Volts. ESP TN

More information

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Safety instructions. IECEx TUN Ex ia IIC T6 Gb Safety instructions ÜSB62-36G.C_* and ÜSB62-30W.C_* IECEx TUN 07.0002 Ex [ia Ga] IIC T6 Gb Ex ia IIC T6 Gb 0044 39878 Content 1 Area of applicability 3 2 General 3 3 Electrical data 3 3.1 Application conditions

More information

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W Switching Power Supply Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W Models range from 10 to 600 W UL 508 approval on 100-W 150-W, 300-W, and 600-W models Wide range of output

More information

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE

More information

Operating Instructions

Operating Instructions Operating Instructions t i SPAN NOT USED - - 4...20mA DISPLAY t i SPAN END POINT DISPLAY Ð - 4...20mA p Safety information, Note Ex area Safety information Please read this manual carefully, and also take

More information

Safety Instructions Cerabar M PMC51, PMP51, PMP55

Safety Instructions Cerabar M PMC51, PMP51, PMP55 XA00470P-B/00/EN/14.13 71224652 Products Solutions Services Safety Instructions PMC51, PMP51, PMP55 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex ia IIC T6...T4 Ga/Gb Ex ia IIC T6...T3 Ga/Gb IECEx

More information

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web:  -   [! -CMT-10-AO-RC-S [!-] General ordering data Type -CMT-10-AO-RC-S Order No. 1510470000 Version Current-measuring transducer GTIN (EAN) 4050118319583 Qty. 1 pc(s). -CMT-10-AO-RC-S Technical data Dimensions

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

LED Driver DC-String

LED Driver DC-String Driver LCU 48V 150W DC-STR FO SR Fixed output Product description Independent fixed output constant voltage LED Driver Compatible with other components Max. output power 150 W Up to 93 % efficiency Nominal

More information

Remote contact signaling available. visual status indication

Remote contact signaling available. visual status indication Effective January 2016 Supersedes August 2013 BUSSMANN SERIES PV PRO three module photovoltaic surge protective devices for 600 and 1000Vdc systems Remote contact signaling available easyid local visual

More information

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards Extract from the online catalog SFP 1-5/120AC Order No.: 2920667 Device surge protection filter to limit powerful surge voltages, mounting on NS 35. Commercial data EAN 4046356158558 Pack 1 pcs. Customs

More information

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications. EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier

More information