Table 1 provides information on the D20MEII/ME CPUs that are being replaced by the D20MX CPUs. Table 1: D20MEII/ME processor boards being replaced

Size: px
Start display at page:

Download "Table 1 provides information on the D20MEII/ME CPUs that are being replaced by the D20MX CPUs. Table 1: D20MEII/ME processor boards being replaced"

Transcription

1 GE Grid Solutions D20MEII/ME to D20MX Quick Start Guide Product Bulletin Date: June 9 th 2016 Classification: GE Information D20ME/D20MEII D20MX This document provides additional information on the D20MX to help answer questions regarding D20MX supported applications, hardware compatibility and some frequently asked questions. Table 1 provides information on the D20MEII/ME CPUs that are being replaced by the D20MX CPUs. Table 1: D20MEII/ME processor boards being replaced Part Number Description D20ME II w RS (VME) 2 MB Flash D20ME II w RS (non-vme) 2 MB Flash D20ME (VME) 2MB Flash, 512 KB NVRAM, 1.5 MB SRAM D20ME (Non-VME) 2MB Flash, 512 KB NVRAM, 1.5 MB SRAM Table 2 provides information on the D20MX CPUs used to replace the D20ME II/ME CPUs. Table 2: D20MX processor boards replacing D20ME/MEII Part Number Description LF D20MX CPU, 2 x 10/100/1000 Base TX Front Access ports (RJ45) LF D20MX CPU, 2 x 100 Base FX Front access ports (ST Connectors) LF D20MX CPU, 2 x 100 Base FX Rear Access ports (supports separate MIC card with ST and LC connectors) 2016 General Electric Company. All rights reserved. * Trademarks of General Electric Company. PRBT-0343 V1.00 R1

2 D20MX Hardware, future-proof platform PRBT GE Information

3 Table 3 provides information on the hardware differences between D20MEII/ME CPUs and the D20MX CPUs. Table 3: Current Hardware Differences between D20MX and D20MEII/D20ME Parameter D20MX D20ME II, D20ME Processor type MPC8360 PQII Pro MC68EC030 CPU frequency 667 MHz 40 MHz Memory size 1.0 GB 1.5 MB NVRAM size 16.0 MB 512 KB - Requires an EME for 8MB and a memory expansion card for 16MB Backup power Super capacitor Lithium Battery Firmware flash 256 MB but 128MB is currently utilized 2.0 MB RTC Clock (Hardware controlled) Yes - 14 day stand-by with Super capacitor No. Power down time saved in NVRAM Ethernet 2 Ports on board (100BaseFX Full duplex) Or, (10/100/1000BaseTX) Or, 2 Port ST/LC MIC (100BaseFX Full duplex) D20 EME required + NIC (10BaseFL Half duplex) D.20 link ports 2 ports 2 ports Serial communication ports 7 to 28 ports (7 main and 7 per serial auxiliary card, with up to 3 serial auxiliary 7 to 42 ports (7 per main board with up to 6 main boards in a D200) cards in a D20 horizontal chassis) IRIG-B support Yes Yes Wesmaint Maintenance Access Front port - Null Modem; Rear port - Wesmaint cable Front port - Wesmaint cable; Rear - Wesmaint cable Multi-node Equivalent functionality planned for future. Yes Size 2U 1U The following table provides information on the LAN redundancy differences between D20MEII/ME CPUs and the D20MX CPUs. Table 4: LAN Redundancy & Standby IP Redundancy D20MX D20ME II, D20ME Redundant LAN D20MX supports the redundant LAN scheme - which is the same mechanism as the classic UR LAN redundancy scheme. Refer to the D20MX Instruction Manual for details. The D20MX assumes redundant LAN operation if only LAN A is configured or if both LANs are configured and Redundancy is set to Redundant LAN in B119-1N (LAN Redundancy Manager DTA for the D20MX). The D20MX supports both IEDs (slave devices) and Master devices that use redundant LAN. The D20MX assumes dual LAN redundancy (i.e., the same scheme used by the D20ME II and D20ME) if both LAN A and B are configured and Redundancy is set to Dual LAN in B119-1N (LAN Redundancy Manager DTA for the D20MX). Standby IP D20MX Standby CCU now has an IP address Not supported Uses the configured IP address + 1 for CCU A and +2 for CCU B Can also be configured with hostname RADIUS authentication is supported on the Standby CCU Not supported natively. Requires the Host Route Monitoring feature of LAN Redundancy Manager DTA (B119). The Host Route Monitoring feature in the B119 application is compatible with IEDs that use Redundant LAN but not with masters that use Redundant LAN. PRBT GE Information

4 Table 5 provides information on the NERC-CIP features in the D20MX. Table 5: Current Security Features Electric Reliability Compliance Security Features D20MX D20ME II, D20ME SSH/SFTP Uses SSH/SFTP - Secure replacements for Telnet and TFTP Unavailable - Uses Telnet and TFTP are unavailable SGConfig supports the Wesmaint terminal (maintenance console) session using SSH SGConfig supports LAN Configuration synchronization to the D20MX using SFTP Brute force password attack protection - locks out IP of attacker for configurable time (3 minutes by default) Insecure Telnet and TFTP Locally Encrypted Passwords Secure LogicLinx Connection Remote Syslog RADIUS with PEAP, EAP-TTLS, or CHAP Role Based Access Control Cleartext password no longer provisioned remotely in SGConfig Unavailable New users are created with default password. Password Passwords must be changed from the D20MX command line complexity not enforced and Passwords stored are one-way encrypted (SHA-256) passwords not Compatible with automated tools such as Cyber-Ark to allow password changes via encrypted an SSH session D20MX uses an authenticated SSH tunnel for the LogicLinx (IEC ) editor Unavailable connection. D20MX sends logs to one or two syslog servers where logs can be archived and Unavailable analyzed in real-time Log format follows Syslog standard for maximum interoperability with third party tools All WESMAINT actions are logged to syslog servers Supports PEAP, EAP-TTLS and CHAP authentication methods Unavailable No need to create individual users in SGConfig, only a set of roles. User roles are assigned to users using the RADIUS server RADIUS server certificate verification modes: RADIUS server certificate must be signed by pre-installed CA certificate and matches pre-defined common name RADIUS server certificate must have an exact match with pre-installed server cert Supports redundant RADIUS servers. If both RADIUS servers are down, then authentication falls back to local password file. While communications between the D20MX and RADIUS server is up, the D20MX does not check user credentials against the local password file. Default configuration contains a role-based access control model defined in the new B014 RADIUS Roles Table. Roles can be added, deleted or modified in SGConfig. Unavailable Robust Communications Stack Reducing Attack Surface Default roles: Administrator, Engineer, Operator, Observer Achieved Wurldtech Achilles Communications Certification Level 1. Infrequently used DNP3/IEC functions are disabled by default. Functions can be individually enabled on a per logical remote unit basis. Unavailable, DNP3 available IEC on roadmap PRBT GE Information

5 D20MX Operating System and Configuration Software Product Bulletin D20MX Operating System: The operating system used by the D20MX is known as VxWorks as opposed to PSOS which is used by the D20MEII and D20ME processors. Both PSOS and VxWorks are made by the same manufacturer, Wind River. VxWorks replaces PSOS. VxWorks: VxWorks is a real-time operating system developed as proprietary software by Wind River Systems of Alameda, California, USA. It is designed for use in embedded systems and it can run on practically any modern CPU that is used in the embedded market. It is used because of the capabilities attributed to real-time performance, reliability, and scalability within a minimal footprint. This is a fit-for-purpose operating system that is robust and enables the D20 for any future development. For more information on VxWorks, visit: D20MX Configuration Software: Although ConfigPro can be used to configure the D20MX, SGConfig is the recommended configuration software for the D20MX and all other GE substation automation products. The D20MX hardware user s manual contains detailed steps on how to configure the D20MX with either SGConfig or ConfigPro. The following operating systems are supported: Microsoft Windows XP Professional 32-bit with 2 GB or more RAM Microsoft Windows XP Professional 64-bit with 2 GB or more RAM Microsoft Windows 7 Professional, Enterprise and Ultimate 32-bit with 4 GB RAM Microsoft Windows 7 Professional, Enterprise and Ultimate 64-bit with 4 GB or more RAM Support is not provided for versions of this product that are installed on operating systems other than those identified above, as the operation of this product has not been verified for any other combinations of operating systems. Note: SGConfig Although ConfigPro will continue to be available, no further development will be done on it. All future development will be done on SGConfig. SGConfig is a PC software-based user interface that allows users of GE substation gateways to efficiently manage configuration files. It includes all of the functionality available in the ConfigPro software while providing enhanced visual representation of a substation hardware configuration and device software configuration. This product is available for download free from the GE s technical support Website or via EnerVista launch pad. CDs can be ordered through GE s Grid Automation Online Store under part number For more information on SGConfig, visit the GE technical support library to download the software or to download the product bulletin PRBT More applications are being developed with each release of the D20MX; Table 6 lists the currently supported applications in the D20MX. Table 6: D20MX Currently Supported Applications Note: * An Application ID containing an N (e.g., A009N) signifies a unique application definition for the D20MX. The D20MX version of the application is based on this D20 classic application version. However, the D20MX version is not identical to the D20 classic version due to minor changes to improve the robustness and security of the original application. PRBT GE Information

6 D20MX Application IDs* Base D20 Classic Application Version Application Name D20MX v1.0 A Communication Watchdog DTA Description Reports on the state of communications between the RTU and a remote device. A027N 832 SOE Logger DTA Sequence of Events Logger DTA. A Accumulator Freeze DTA Detects system status point changes and system accumulator point freezes. A033-5N 211 TEJAS V DPA Valmet TEJAS V DPA. A Analog Reference DTA Monitors analog input points and provides the system database with pseudo analog values that represent either correctly functioning analog input hardware (good reference value), or failed analog input hardware (bad reference value). A036N 421 ProLogic Executor DTA Provides user programmable soft logic automation functionality. A059N 911 Modbus DCA Modbus (RTU & ASCII modes) DCA A068N 311 Modbus DPA Modbus (RTU & ASCII modes) DPA A Substation Maintenance DTA Allows status and analog input values to be suppressed for maintenance purposes. A113N 301 PSR DCA Programmable Synchrocheck Relay (PSR) DCA A Failover DTA Allows configurable combination of control requests to result in a failover or switchover of a redundant system. A NGC General DTA Generates control lockout indications, digital input suppression or unsuppression indications, and control active indications A General Alarm DTA Takes several alarms and groups them together under one General Alarm. B D.20 Peripheral Link DCA D.20 peripheral link DCA. B System Point Database Maintains the database of system points in the RTU B Mailbox DTA Mailbox system point conversion application B012N 201 IRIG-B DCA IRIG-B DCA B DNP V3.00 Data Link Distributed network protocol (DNP) V3.00 data link. B014-1N 520 WESMAINT II+ RTU maintenance facility. B Bridgeman Bridge manager B021N 991 DNP V3.00 DPA Distributed Network Protocol (DNP) V3.00 DPA. B DNP V3.00 DCA Distributed Network Protocol (DNP) V3.00 DCA. B034N 203 Redundant Monitor Monitors CCU states and initiates failover. Also, receives command requests to perform database synchronization, switchover and failover. B D20AC WESMAINT II+ Provides D20AC WESMAINT II+ displays. Display Screens B052-0N 351 DNP Internet Data Link DNP V3.00 Data Link over Internet. B WESMAINT File Upload Uploads files via the WESMAINT port as S records or using ZMODEM. B Internet Protocol Stack Internet Protocol Stack PRBT GE Information

7 D20MX Application IDs* Base D20 Classic Application Version Application Name Description B152-0N n/a IP Redundancy Monitor Provides health and active pseudo DI points for LAN Ports. DCA D20MX v1.1 A Calculator DTA Convenient and flexible soft logic utility that can perform applications such as substation level interlocking, feeder interlocking, and converting digital inputs to control outputs for driving a map board D20MX v1.2 A009N 805 PG&E DPA Communicates to Master Stations via PG&E protocol A078N 610 SEL DCA Communicates to IEDs via SEL protocol A101-0N 906 IEC /104 DPA Communicates to Master Stations via IEC 101/104 protocol A185-0N 110 LG 8979 DPA Communicates to Master Stations via LG 8979 protocol A199-0N 106 HR6000/XA-21 DPA Communicates to Master Stations via Harris protocol B058-0N 231 IEC FT1.2 Primary FT 1.2 primary data link configuration Data Link B IEC /104 DCA Communicates to IEDs via IEC 101/104 protocol B IEC Balanced IEC FT1.2 balanced data link Mode Data Link B IEC Data Link IEC data link D20MX v1.3 A017N 131 DNP1 Data Link Distributed Network Protocol (DNP) V1.0 Data Link Application. Required by the Quantum Meter Scanner DCA. A Quantum Meter Scanner DCA The Quantum Meter Scanner DCA obtains data from one or more Quantum Meters via the DNP interface. A023N 423 CDC Type I DPA The CDC Type I DPA emulates a CDC Type I RTU A Proportional Integral Derivative (PID) Controller The Proportional, Integral and Derivative (PID) DTA uses the generally-accepted industry standard for control of closed loop processes. A MODBUS TCP/IP DCA Provides an interface to Sub-Remote Units (SRUs) using the MODBUS protocol over the TCP/IP communication layer. A MODBUS TCP/IP DPA Provides communications with one or more master station using the MODBUS protocol over TCP/IP communication layer. A Redundant I/O DTA Provides I/O point redundancy. B082-0N 311 LogicLinx Executor The LogicLinx executor is responsible for executing PLC programs written using the LogicLinx PLC (IEC compliant) editor. B SNTP Client The Simple Network Time Protocol (SNTP) client application provides reasonably accurate and reliable time synchronization. B Time Zone and DST Settings DTA The Time Zone and DST (Daylight Saving Time) provides a time zone and DST information to other applications. PRBT GE Information

8 D20MX Application IDs* Base D20 Classic Application Version Application Name Description D20MX v1.4 A Status Combination DTA Provides one or more DI points, each of which provides an event-driven logical OR of a set of mapped system DI points. A Western Power Distribution (WPD) DTA Calculates power from monitored voltage, current, and phase angle. Also, performs time integrated analog averaging, relative to the top of the hour. Performs time integrated analog averaging, relative to the top of the hour. A Top of the Hour Analog Averaging DTA A Cooper 2179 DCA Monitors and controls Cooper devices using the Cooper 2179 protocol. A104-0N 124 Alarm Grouping DTA for Provides DI points each representing a group alarm. The the D20MX group alarm is generated when the number of DI points in A Automatic Frequency Selection DTA the alarm state exceed the group threshold value. Provides AI points each derived from an Automatic Selection Method (ASM). An ASM selects the highest priority valid frequency measurement from a group of AI points. A Secondary Master Trip/Close DTA Translates control requests into conventional trip/close operations in conjunction with secondary control operations to be used as a Secondary Master Trip or Close. B IEC DCA Monitors and controls devices using the IEC protocol. B119-1N 103 LAN Redundancy Manager DTA Provides health and active pseudo DI points for LAN Ports, as well as default gateway monitoring and advanced routing configuration. D20MX v1.5 A064N 110 Tap Position Indication DTA Translates a digital input point from a range of status points into an analog input value. A065N 202 CL&P DTA The China Light and Power DTA performs miscellaneous functions as follows: Julian day/year download, Raise/lower operations, RTS time synchronization. A074N 120 PML 3710 DCA Enables the D20MX to communicate with PML 3710 ACM power meters. A098-0N 701 Courier DCA Enables communication with Courier SRUs (predominantly GEC K-Bus protection relays). The following sections provide information on some hardware compatibility between the D20MX and existing D20 hardware. PRBT GE Information

9 D20MX Hardware Compatibility Product Bulletin The D20MX does not require and is not compatible with D20ME Memory Expansion and Media Interface Modules. The D20MX s design permits only one D20MX CPU to be installed. Additional D20MX CPU s within the same chassis are not currently required nor supported. Note: Backwards compatibility with currently sold D20 hardware is maintained. For all older hardware with D20 base system firmware, an upgrade to a CCU base system is recommended. The part number of a D20 firmware can determine if a system is a D20 base system or a CCU base system. Include this firmware information when contacting GE to determine hardware compatibility. D.20 Peripherals Support for D.20 I/O modules is maintained. The D20MX is compatible with the following PCOMMON, PCOMMON2 and PBOOT Compatible D.20 peripheral chip types PCOMMON [ For D20 A, S, K modules] PCOMMON2 [ For D20 C module] pboot [ For D20AC module] P010 v3.06 P022 v3.05 P087 v1.04 P010 v3.05 P022 v3.00 P087 v1.03 P010 v3.01 P087 v1.02 P010 v3.00 Power Supply Support for D20 power supplies is maintained. The D20MX is compatible with the D20 power supplies listed in Table 7. Table 7: Compatible Power Supplies Product Part Number Description D20 POWER SUPPLY, 20-60VDC IN, 24V ISO OUT Power Supply D20 POWER SUPPLY, 20-60VDC IN, 48V ISO OUT D20 PS, VDC/85-264VAC IN, 24V ISO OUT D20 PS, VDC OR VAC IN, 48V ISO OUT V@12A 115/230VAC Power Supply V@12A 36-72VDC /-12V@2A 115/230VAC /-12V@2A 36-72VDC Chassis The support for VME and non-vme chassis is maintained. The D20MX currently supports both D20 VME and D20 non-vme horizontal chassis types. Support for up to 35 serial ports including backwards compatibility with the vertical D200 chassis will be ensured in the next D20MX release, scheduled for May-June, When using a D20MX in a horizontal D20 VME chassis, the 0 V ground wire must be used. The part number for this 0V ground wire is: See page 34 of the D20MX Instruction manual (GE part number ) for more details on set-up and PRBT GE Information

10 connections. The ground wire comes as an accessory within the D20MX upgrade kit and comes pre-connected in a fully assembled D20MX system. Table 8: D20 VME Chassis Compatibility Component GE Item # Description Compatibility D20 VME Chassis CHASSIS * CHASSIS ASSY D20 M (VME 3U) REL 16A-higher BACKPLANE WESTERM D20 M VME REL 03-higher WESTERM WESTERM D20M+, PANEL MOUNT REL 09-higher WESTERM D20 ASSY, CHASSIS MOUNT * 0V cable required from WESTERM to Backplane Table 9: D20 Non-VME Chassis Compatibility Component GE Item # Description Compatibility D20 Non-VME Chassis CHASSIS CHASSIS, D20M+ SINGLE SLOT REL 26-higher WESTERM WESTERM D20M+, SINGLE SLOT REL 15-higher Multilin D20MX Availability Simple to Advanced Substation Automation Control Distribution and transmission industries are under pressure to ensure that their grids are reliable and to prolong the usability of their assets. Data from these assets can be collected, aggregated and processed, to provide visibility of system conditions. The Multilin TM D20MX Substation Controller is a specialized computing platform designed to execute communications and energy management applications for the monitoring and control of electrical substations. The D20MX is capable of amalgamating data from multiple slave devices and D20 I/O modules connected via communication channels into a single database using various protocols. The D20MX can execute local logic, compile data, process it through one of multiple applications and report the results upstream to master stations through different server protocols. The D20MX is available online and can be purchased. D20MX Substation Controller: D20MX Kit: Note: Prologic is no longer supported. LogicLinx serves as its replacement. The prologic executor exists in order to allow existing RTU s prologic configurations/logic to be accessible and managed. However, the prologic editor is no longer supported and maintained. D2X Classic Applications requiring license Application ID Name A009 PG&E DPA A003-5 Tejas V DPA A036N Prologic Executor DTA A113 PSR DCA A185-0 LG 8979 DPA A199-0 HR6000/XA-21 PRBT GE Information Buy Now

11 Near future D20MX Releases D20MX v1.5 - Release date June, 2015 Additional 28 serial ports expansion D200 vertical chassis support LogicLinx 64-bit OS Support A074 PML 2710 DCA Courier DCA Tap Position Indication DTA CLP DTA Frequently Asked Questions This section identifies some of the frequently asked questions. Review the D20MX hardware user s manual for more complete details. 1. Is the D20MX NERC-CIP certified? A: A single device cannot be NERC-CIP certified. NERC-CIP contains a list of requirements that are used to regulate utilities or users with network devices connected to the power grid. Such a complete list of requirements covers a wide range of organization standards and philosophies regarding critical asset s security and reliability. It also contains the requirements for an electronic device that is connected to the network grid. The D20MX s offers a unique set of Network security features that allows any user or network security auditor to demonstrate that it is securely connected to the network. It ensures this by not only providing a user with an authenticated and authorized access and audit but also allows a security auditor to account for who has accessed the D20MX. See the hardware user s manual for more details. 2. Since the D20MX does not currently support all the protocols and applications present in the D20ME and D20MEII, what is GE s plan to address this? A: The following are recommended: Short-term: o Identify what protocols and applications are critical [enabled] in your existing D20/D200 configuration file or project o Compare this protocol and application list with the current list of D20MX supported protocols and applications o Provide your complete contact information and sample configuration file including firmware to GE for support on an alternate implementation for any missing functionality. This will be classified as a product/technical application engineering deliverable and a recommendation will be provided from an application engineering/development stand-point. Long-term: o If the identified protocols and applications are critical and needed natively in the D20MX, provide your complete contact information and sample configuration file including firmware and contact GE to understand how this can be included in future D20MX release. 3. Since the D20MX does not currently support more than 7 serial communication ports and multiple nodes CPU, what is GE s plan to address this? A: If the concern is the need for the D20MX to be able to handle large configuration and communication loading, the D20MX s current design has more than enough RAM and capability to process data more efficiently and more quickly in comparison to a D200 with several CPU nodes. PRBT GE Information

12 If the concern is the need for the D20MX to support more than 7 serial communication ports, an additional 28 serial ports will be supported in the next release of the D20MX, v1.5. This release is scheduled for June What impact does a large configuration have on the D20MX? A: The following D20MX configuration system has been proven to run with no resource problems: o With over 460 slave devices configured o With over 250 devices communicating online o With 70, 000 points configured o 100ms concurrent polling resulted in 25% idle time o 1s concurrent polling resulted in 80% idle Note: With this configuration setting, 780MB was still available. 5. How is hardware and software redundancy different in the D20MX relative to both D20MEII and D20ME? A: The existing hardware and software configuration for redundancy are the same in the D20MX as they are in the D20MEII and D20ME. All hardware parts used for redundancy are identical and compatible with the D20MX. The only thing that has changed is the main CPU processor [D20MX instead of D20ME or D20MEII]. The software configuration and philosophy are the same. See the D20MX hardware user s manual for more details. In addition, CCU switch-over is now also possible based on LAN health: o If both LAN ports fail on active CCU, switchover occurs. o In the standby CCU, switchover is prevented if both LAN ports are down. o LAN port is considered healthy: If link signal is present and If far-end fault indication is not present Note: CCU switch-over based on LAN health is configurable in the B034 [Redundant Monitor]. It is disabled by default. 6. Does the D20MX support the configuration of multiple LAN IP similar to the D200 s multi-ip addressing? A: Yes. This is done through the LAN Redundancy Application. Multiple LAN IP addresses up to 16 can be configured 7. What are the key things to consider when upgrading a D20ME or D20MEII to a D20MX? A: Software considerations: SGConfig is the recommended software to configure or transfer an existing D20 configuration into a D20MX configuration type. However, ConfigPro can also be used. Details are documented in the D20MX hardware user s manual. SGConfig supports secure means of transferring files. The current procedures to convert a D20 or a D200 configuration into a D20MX configuration are not automatic It is recommended to migrate a project rather than a device to prevent partial loss of configuration data related to Ethernet/LAN A: Hardware considerations: The current D20MX processor boards exist in 3 types LF: D20MX CPU, 2 x 10/100/1000 Base TX Front Access ports (RJ45) LF: D20MX CPU, 2 x 100 Base FX Front access ports (ST Connectors) LF: D20MX CPU, 2 x 100 Base FX Rear Access ports (supports separate MIC card with ST and LC connectors) PRBT GE Information

13 If a door exists in the cabinet where a D20MX is to be installed, to avoid a pinch on the Ethernet cable while closing the door to the cabinet, the D20MX processor type LF may be the most appropriate processor type to be used. The LF processor type uses a separate fiber media interface whose Ethernet ports are at the rear. Both LC and ST connectors are available for the media interface card. Note: The LF processor type is compatible with D20 VME chassis Rel 08 or higher. The LF is currently the only copper connection type. Access to the Ethernet ports is in the front. The maintenance serial port at the front of the D20MX uses a NULL modem cable [ ]. The standard WESMAINT cable should never be used with this front port. Conversely, the rear WESMAINT port requires the standard WESMAINT cable [ ]. Failure to adhere to this could cause damage to the maintenance port and to the D20MX. Both the front and back wesmaint interface ports should not be used simultaneously The D20MX s supports both VME and non-vme chassis. However, the chassis type currently supported is the horizontal type. In D20MX v1.5, the vertical D200 chassis type will be supported Use of the D20MX in a VME chassis requires a 0V ground wire with part number: This cable is used to connect the zero volt TB2 terminal block on the to the zero volt on the See page 34 of the D20MX hardware user s manual for more details. The zero volt wire comes as a loose item if a D20MX upgrade Kit is ordered. If a complete D20MX system is ordered, the 0V connection is pre-connected into the D20MX system before it is shipped out from the factory. The current D20MX hardware supports only 7 serial ports. In D20MX v1.5, additional 28 serial ports will be supported. This release is scheduled for June What is the recommended operating temperature range of the D20MX? A: The operating temperature range is 0 C to +70 C. Do not operate the D20MX above 60 C for extended periods of time as this shortens the life of the super capacitor and reduces the backup time of the real time clock. 9. How does configuration storage work in the D20MX? A: The D20MX employs the use of a Super capacitor. This allows the retention of the system clock time for 14-days. At power-up, the configuration is stored in the RAM. At power-down, configuration is seamlessly transferred to the flash from the RAM. This arrangement protects the D20MX configuration from being lost, even after power-down for an indefinite period of time. See the D20MX manual for steps to deleting the configuration. 10. Exactly what stored information does the super capacitor backup? A: There are two super capacitors. The large one provides enough power for the D20MX to save 16MB of RAM (starting at 0xD , which is aliased to 0x ) to backing flash after the main power is lost. When the D20MX starts from cold, it restores the backing flash to the 16MB of RAM. \ The combination of RAM and backing flash is how NVRAM is implemented on the D20MX. NVRAM storage contains configuration and various runtime information like: points configured to be in NVRAM, SOE reporting queues configured to be in NVRAM, and communications statistics configured to be in NVRAM PRBT GE Information

14 11. Does the super capacitor keep the internal clock running? A: The second smaller capacitor powers the hardware RTC or time of day clock for 14 days without main power. If power is restored to the D20MX within 14 days, the board will come up with the correct time within a few seconds (the hardware RTC has an accuracy of 20 PPM). Note that when the D20MX is powered, it makes use of a 2 PPM clock. The hardware RTC is used only while the D20MX is powered down. 12. Where does the firmware reside in? A: The firmware resides in the flash. 13. Is the prologic application still supported in the D20 [D20MX or predecessors]? A: Prologic is no longer supported. Logiclinx serves as its replacement. The prologic executor exists in order to allow existing RTU s prologic configurations/logic to be accessible and managed. However, the prologic editor is no longer supported and maintained. 14. Is the configuration file in flash or backed-up RAM? A: The configuration file is in NVRAM, with a backup on the primary flash chip. On startup, if the NVRAM configuration header is detected to be corrupted, the D20MX will restore the copy on the primary flash chip to NVRAM. Restoring from the backup on the primary flash chip would be very unlikely and only happen if a software or hardware issue corrupted the NVRAM. 15. What PCOMMON chips and versions are compatible and are to be used with the D20MX? A: The following are compatible with the D20MX: PCOMMON [ For D20 A, S, K modules] PCOMMON2 [ For D20 C module] pboot [ For D20AC module] P010 v3.06 P022 v3.05 P087 v1.04 P010 v3.05 P022 v3.00 P087 v1.03 P010 v3.01 P087 v1.02 P010 v What is the need for the extended brackets option when ordering the Serial I/O term panel option? A: Since the rear fiber option D20MX processor [ ] requires a separate MIC card, whose Ethernet ports are in the rear, the extended brackets allow for the extra spacing for the cabling and connections required from the MIC card to this D20MX processor. Even if the processor type is not selected, the extended brackets option provides the extra spacing that may also be required during installation. PRBT GE Information

15 Support Contact Sales For more sales information, contact your local sales representative or us at: Customer Service: Returns and Repairs/Technical Support The GE Grid Solutions Customer Service Center is open from 9am-5pm Eastern Time zone during business days and 24 hours, seven days a week, in case of emergencies, for you to talk directly to a GE representative. In the U.S. and Canada, call toll-free: International customers, please call: To log a technical support or customer service request, send an to: multilin.tech@ge.com. For any questions regarding this notice, track such a request by contacting the customer service support team at: multilin.tech@ge.com Training For training on the D20ME/MEII or D20MX, send your request to: Training.Multilin@ge.com If you need help with any aspect of your GE Grid Solutions product, you have a few options: Supporting Documents The following are available to guide users through the D20ME/MEII to D20MX upgrade process: D20MX Hardware Manual v1.40 rev 0 D20MX Brochure PRBT-0305 D20MX D2x - NERC-CIP5 Response V101 R0 Documents are available online: Search Technical Support The GE Grid Solutions Web site provides fast access to technical information, such as manuals, release notes and knowledge base topics. Visit us on the Web at: Login to the technical support portal: We trust that this information assures you that GE Grid Solutions is committed to the continued support of the D20 product line. We appreciate your business and look forward to working with you through the qualification and adoption of the D20MX and though-out the transition from the D20 ME/MEII to the D20MX. PRBT GE Information

16 Copyright Notice Product Bulletin 2016, General Electric Company. All rights reserved. The information contained in this online publication is the exclusive property of General Electric Company, except as otherwise indicated. You may view, copy and print documents and graphics incorporated in this online publication (the Documents ) subject to the following: (1) the Documents may be used solely for personal, informational, non-commercial purposes; (2) the Documents may not be modified or altered in any way; and (3) General Electric Company withholds permission for making the Documents or any portion thereof accessible via the internet. Except as expressly provided herein, you may not use, copy, print, display, reproduce, publish, license, post, transmit or distribute the Documents in whole or in part without the prior written permission of General Electric Company. If applicable, any use, modification, reproduction, release, performance, display, or disclosure of the Software Product and Associated Material by the U.S. Government shall be governed solely by the terms of the License Agreement and shall be prohibited except to the extent expressly permitted by the terms of the License Agreement. The information contained in this online publication is subject to change without notice. The software described in this online publication is supplied under license and may be used or copied only in accordance with the terms of such license. Trademark Notice GE and the GE monogram are trademarks and service marks of General Electric Company. * Trademarks of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies. Document Revision History Version Revision Date Author Change Description March 31, 2015 K. Odetunde Created 1 June 13, 2016 K. Odetunde Replaced the tables in sections: - D20MX Hardware, future-proof platform - D20MX Operating System and Configuration Software PRBT GE Information

The D20MX and its Predecessors Features and Functionality

The D20MX and its Predecessors Features and Functionality GE TN0049 V1.00 R0 Digital Energy Substation Controller - D20MX Technical Note The D20MX and its Predecessors Features and Functionality Overview The D20MX Substation Controller is a specialized computing

More information

The D20MX and its Predecessors Features and Functionality

The D20MX and its Predecessors Features and Functionality GE Grid Solutions Substation Controller - D20MX TN0049 V1.50 R1 Technical Note The D20MX and its Predecessors Features and Functionality Overview The D20MX Substation Controller is a specialized computing

More information

D20ME II/ME Replaced Effective Immediately

D20ME II/ME Replaced Effective Immediately GE Grid Solutions D20ME II/ME Replaced Effective Immediately Product Bulletin Date: February 24 th 2017 Classification: GE Information D20ME/D20MEII D20MX The D20MX substation controller replaces both

More information

Product Bulletin. SGConfig Configuration Tool v8.3. GE Digital Energy. Release Notification of SGConfig 8.3. SGConfig v8.

Product Bulletin. SGConfig Configuration Tool v8.3. GE Digital Energy. Release Notification of SGConfig 8.3. SGConfig v8. GE Digital Energy SGConfig Configuration Tool v8.3 Product Bulletin Date: January 5, 2015 Classification: GE Information Release Notification of SGConfig 8.3 SGConfig is a PC software-based user interface

More information

Product Bulletin. SGConfig Configuration Tool v9.0. GE Grid Solutions. Release Notification of SGConfig 9.0. Before Installation

Product Bulletin. SGConfig Configuration Tool v9.0. GE Grid Solutions. Release Notification of SGConfig 9.0. Before Installation GE Grid Solutions SGConfig Configuration Tool v9.0 Product Bulletin Date: August 11, 2016 Classification: GE Information Release Notification of SGConfig 9.0 SGConfig is a PC software-based user interface

More information

GE Grid Solutions D20MX. Substation Controller. Instruction Manual Version 1.5x Revision 4. GE Information

GE Grid Solutions D20MX. Substation Controller. Instruction Manual Version 1.5x Revision 4. GE Information GE Grid Solutions D20MX Substation Controller Instruction Manual 994-0140 Version 1.5x Revision 4 GE Information GE Grid Solutions Copyright Notice 2012-2016, General Electric Company. All rights reserved.

More information

SGConfig Configuration Tool v11.1 R0 Product Bulletin

SGConfig Configuration Tool v11.1 R0 Product Bulletin GE Grid Solutions SGConfig Configuration Tool v11.1 R0 Date: December 11 th, 2018 Classification: GE Information Publication Number: PRBT-0416 Release Notification of SGConfig 11.1 SGConfig is a PC software-based

More information

Standard Req # Requirement D20MX Security Mechanisms D20ME II and Predecessors Security Mechanisms

Standard Req # Requirement D20MX Security Mechanisms D20ME II and Predecessors Security Mechanisms GE Digital Energy D20MX - NERC - CIP Response Product Bulletin Date: May 6th, 2013 Classification: GE Information NERC Critical Infrastructure Protection Response Overview The purpose of this document

More information

Want to Upgrade a Part? Yes. 4. Refer to the Spare Part Compatibility Matrix ( Appendix 2 ) 3. Refer to the D25 Upgrade to Gen 4 Matrix (Appendix 1)

Want to Upgrade a Part? Yes. 4. Refer to the Spare Part Compatibility Matrix ( Appendix 2 ) 3. Refer to the D25 Upgrade to Gen 4 Matrix (Appendix 1) GE Grid Solutions D25 Multifunction IED Product Bulletin Date: April 8, 2016 Classification: GE Information D25* Part Compatibility and Upgrade Guide The D25 is currently in of production. Previous generations

More information

GE Digital Energy D20MX. Processor. Hardware User s Manual Version 1.20 Revision 0. GE Information

GE Digital Energy D20MX. Processor. Hardware User s Manual Version 1.20 Revision 0. GE Information GE Digital Energy D20MX Processor Hardware User s Manual 994-0140 Version 1.20 Revision 0 GE Information GE Digital Energy Copyright Notice 2012-2013, General Electric Company. All rights reserved. The

More information

A new D GHz CPU main board [REV: B01 or newer]. See Figure 1 New D GHz Main board (Rev: B01).

A new D GHz CPU main board [REV: B01 or newer]. See Figure 1 New D GHz Main board (Rev: B01). GE Digital Energy D400 CPU Migration Instructions TN00062 V1.00 R0 Technical Note This document: Provides the steps required to migrate existing firmware and configuration files to a 1.6 GHz D400. Applies

More information

The vendor shall have implemented an ISO 9001 certified Quality Management System.

The vendor shall have implemented an ISO 9001 certified Quality Management System. SMP Gateway SMP4DP Substation Gateway Guideform Specification Guide 1. Scope This specification describes the features and specifications of the SMP Gateway, as part of Eaton s Cooper Power Systems Substation

More information

A new D GHz CPU main module [Rev: B01 or newer]. See Figure 1 New D GHz Main module (Rev: B01).

A new D GHz CPU main module [Rev: B01 or newer]. See Figure 1 New D GHz Main module (Rev: B01). GE Digital Energy D400 CPU Migration Instructions TN00062 V1.00 R2 Technical Note This document: Provides the steps required to migrate existing firmware and configuration files to a 1.6 GHz D400. Applies

More information

Remote Terminal Unit ER1000 APPLICATION FEATURES

Remote Terminal Unit ER1000 APPLICATION FEATURES Remote Terminal Unit ER1000 ERL with more than three decades of expertise in Power System Protection have developed state of the art Automation Solutions. The whole family of ERL s Remote Terminal Unit

More information

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller SEL-3530 Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller Versatile RTAC operates as a supervisory control and data acquisition (SCADA) remote terminal unit

More information

UA-5200 IIoT Communication Server

UA-5200 IIoT Communication Server UA-5200 Series UA-5200 IIoT Communication Server Features OPC UA Server and MQTT Client Service MQTT Broker Inside AM3354, 1 GHz 256 MB RAM and 512 MB Flash Linux kernel 3.2.14 OS Real-Time Capability

More information

QEI. SCADA Remote Gateways & RTUs Substation & Feeder Automation Capacitor Control

QEI. SCADA Remote Gateways & RTUs Substation & Feeder Automation Capacitor Control QEI SCADA Remote Gateways & RTUs Substation & Feeder Automation Capacitor Control Industry Leadership QEI is a leading SCADA system and substation automation equipment supplier with a long history of innovation

More information

Ovation Controller Model OCR1100

Ovation Controller Model OCR1100 Ovation Controller Model OCR1100 Features Secure, reliable and mission-critical control capability providing bumpless automatic failover between redundant controllers. Fast processor for increased productivity

More information

SCADAPack Smart RTU

SCADAPack Smart RTU SCADAPack 330 334 Smart RTU 1 Built on the proven SCADAPack 300 platform, the SCADAPack 330 and 334 feature high-performance 32-bit processing, highspeed LAN, serial and USB communications, integrated

More information

SCADA. SurvalentONE. STC Explorer

SCADA. SurvalentONE. STC Explorer SurvalentONE SCADA SurvalentONE SCADA Survalent SCADA is a software automation solution to provide real-time control and data acquisition for utility operations. Survalent SCADA software includes STC Explorer

More information

Multilin D400. Advanced Substation Gateway Secure, Consolidated Substation Communications. Advanced Automation. Security. Connectivity.

Multilin D400. Advanced Substation Gateway Secure, Consolidated Substation Communications. Advanced Automation. Security. Connectivity. Multilin D400 Advanced Substation Gateway Secure, Consolidated Substation Communications GE s Multilin D400 is a secure, substation-hardened gateway that collects metering, status, event, and fault report

More information

Orion. An Overview of the Orion Automation Platform

Orion. An Overview of the Orion Automation Platform Orion An Overview of the Orion Automation Platform The Best Substation Automation Platform Out There Is in Here The Orion Family of Substation Automation Platforms and I/O perform an expanding array of

More information

D400 TM Substation Gateway

D400 TM Substation Gateway GE Digital Energy D400 TM Substation Gateway Software Configuration Guide SWM0066 Version 4.10 Revision 4 GE Information Copyright Notice 2007-2015, General Electric Company. All rights reserved. The information

More information

CG Automation Solutions User Newsletter

CG Automation Solutions User Newsletter Upgrade Now to an epaq-94xx at no Charge The epaq-94xx series of gateways provide a unique and powerful path to substation and distribution automation. And now, for a limited time, you can receive a free

More information

PIX 535. PIX 535 Product Overview CHAPTER

PIX 535. PIX 535 Product Overview CHAPTER CHAPTER 7 PIX 535 This chapter describes the installation of the PIX 535, and includes the following sections: PIX 535 Product Overview Installing a PIX 535 PIX 535 Feature Licenses Installing Failover

More information

SCADAPack ES. Smart RTU

SCADAPack ES. Smart RTU Smart RTU 1 Meeting the demands for high-speed distributed control and automation systems, Schneider Electric offers the as an advanced Smart RTU. Our highest performance Smart RTU built on a native DNP3

More information

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web:   ; User s Manual Management Converter Chassis Model No.: SP1386 / SP1387 World Wide Web: www.micronet.com.tw ; www.micronet.info Table of Content 1. INTRODUCTION... 2 1.1 PACKAGE CONTENT... 2 1.2 KEY FEATURES...

More information

Scout-S Station Controller

Scout-S Station Controller Scout-S Station Controller Substation Automation Scout-S Station Controller The Scout-S Station Controller is a SCADA enabled remote terminal unit (RTU) with a data concentrator, event reporter, and built-in

More information

MINER-S Station Controller

MINER-S Station Controller MINER-S Station Controller Substation Automation MINER-S Station Controller The MINER-S Station Controller is a SCADA enabled fixed point remote terminal unit (RTU) with a data concentrator, event reporter,

More information

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! The Fiberoptic Communications Specialists The Model 570E offers high-speed serial communication to meet the challenging needs of distribution

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

A PACSystems RX3i Ethernet NIU I/O Station

A PACSystems RX3i Ethernet NIU I/O Station A PACSystems RX3i Ethernet NIU I/O Station A PACSystems RX3i Ethernet NIU I/O Station consists of: an RX3i power supply, IC695PSxxxx an RX3i Ethernet NIU, IC695NIU001 (NIU001 Classic or NIU001 Plus) Note:

More information

Multilin D400. GE Grid Solutions. Advanced Automation. Advanced Substation Gateway Secure, Consolidated Substation Communications.

Multilin D400. GE Grid Solutions. Advanced Automation. Advanced Substation Gateway Secure, Consolidated Substation Communications. GE Grid Solutions Multilin D400 Advanced Substation Gateway Secure, Consolidated Substation Communications GE s Multilin D400 is a secure, substation-hardened gateway that collects metering, status, event,

More information

I/A Series HARDWARE Product Specifications

I/A Series HARDWARE Product Specifications I/A Series HARDWARE Product Specifications I/A Series Station Computing Device (SCD) SCD5200 CPU OptoNet Power Supply Ethernet (COPE) Module/ SCD5200 CPU OptoNet Ethernet (COE) Module PSS 21H-8G3 B4 FEATURES

More information

Multilin 650 Family. Firmware v7.60, Software v7.60 Release Note. GE Grid Solutions. Summary

Multilin 650 Family. Firmware v7.60, Software v7.60 Release Note. GE Grid Solutions. Summary GE Grid Solutions Multilin 650 Family Firmware v7.60, Software v7.60 Release Note Copyright 2017 GE Multilin Inc. Summary GE Grid Solutions issues the Multilin 650 Family Firmware version 7.60 and Enervista

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide Trademark Notices Comtrol, NS-Link, and DeviceMaster are trademarks of Comtrol Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.

More information

Index. B Boot software 5-2 Bridging architecture 7-6 Broadcast filter 8-55 limiting 8-22 Buffer port 7-9 Syslog 8-17, 8-20

Index. B Boot software 5-2 Bridging architecture 7-6 Broadcast filter 8-55 limiting 8-22 Buffer port 7-9 Syslog 8-17, 8-20 Index Numerics 10/100 mode 8-27 1000BaseLx 7-10 1000BaseSx 7-10 1000BaseT 7-10 100BaseFx 7-10 100BaseFx Ports 7-10 100BaseTx 7-10 10BaseT 7-10 802.3x Gigabit negotiation 8-29 9304M Routing Switch 2-9 9308M

More information

Raising the standard Upgrading the Series 90-30

Raising the standard Upgrading the Series 90-30 Raising the standard Upgrading the Series 90-30 October 2015 Imagination at work Series 90-30 - the most versatile controller in history 2 CPU 311/313/323 CPU 33x/34x/35x/36x Backplane CPU 5 and 10 slot

More information

PIX 520. PIX 520 Product Overview CHAPTER

PIX 520. PIX 520 Product Overview CHAPTER CHAPTER 5 PIX 520 This chapter guides you through the installation of the PIX 520, and includes the following sections: PIX 520 Product Overview, page 5-1 Installing the PIX 520, page 5-4 PIX 520 Feature

More information

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications RTU 20 OVERVIEW The I/A Series RTU 20 is an Intelligent Remote Device capable of performing a full range of control

More information

NovaTech Orion I/O Overview

NovaTech Orion I/O Overview NovaTech Orion I/O 2 NOVATECH ORION I/O 3 NovaTech Orion I/O Overview NovaTech Orion I/O is an extension of the family of OrionLX Automation Platforms for substation automation and incorporates the same

More information

A low-cost, economical solution for distribution feeder protection

A low-cost, economical solution for distribution feeder protection SEL-351A Protection System A low-cost, economical solution for distribution feeder protection Achieve sensitive and secure fault detection using comprehensive protection functions. Track breaker status

More information

OrionLX. An Overview of the OrionLX Product Line

OrionLX. An Overview of the OrionLX Product Line OrionLX TM An Overview of the OrionLX Product Line The Best Substation Automation Platform Out There Is in Here The OrionLX Family of Substation Automation Platforms perform an expanding array of automation

More information

Designing a new IEC substation architecture

Designing a new IEC substation architecture Designing a new IEC 61850 substation architecture Gerrit Dogger Senior Product and Application Specialist Cooper Power Systems gerrit.dogger@cybectec.com Garry Tennese Station Integration Specialist Manitoba

More information

DDFR. Instruction Manual * A3* GE Consumer & Industrial Multilin. Distributed Digital Fault Recorder. Software Revision: 3.

DDFR. Instruction Manual * A3* GE Consumer & Industrial Multilin. Distributed Digital Fault Recorder. Software Revision: 3. GE Consumer & Industrial Multilin DDFR Distributed Digital Fault Recorder Instruction Manual Software Revision: 3.0x Manual P/N: 1601-9024-A3 Manual Order Code: GEK-113333B Copyright 2008 GE Multilin GE

More information

MINER-S Station Controller. Substation Automation

MINER-S Station Controller. Substation Automation Substation Automation MINER-S Station Controller incorporates traditional RTU functions with new technology in a compact design MINER-S Station Controller combines the functions of a traditional RTU with

More information

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution UR An integrated feeder protection and metering solution Power to Manage your Facility Connectivity ModBus RTU MMS/UCA2 TM Protocols SI Compatibility Flexibility FlexCurves FlexLogic The first Relay designed

More information

Overview of the Cisco VG224 Voice Gateway

Overview of the Cisco VG224 Voice Gateway CHAPTER 1 This chapter provides a brief description of the Cisco VG224 voice gateway (VG) and contains the following sections: Overview, page 1-1 Cisco VG224 Voice Gateway Deployment, page 1-4 Interfaces

More information

Substation. Communications. Power Utilities. Application Brochure. Typical users: Transmission & distribution power utilities

Substation. Communications. Power Utilities. Application Brochure. Typical users: Transmission & distribution power utilities Power Utilities Application Brochure Communications Typical users: Transmission & distribution power utilities For more than 30 years, RAD has worked closely with its worldwide energy utility customers

More information

SEL-2414 Transformer Monitor

SEL-2414 Transformer Monitor SEL-2414 Transformer Monitor SEL-2414 Base Unit Vertical Chassis Front Panel Large LCD Display 4 Programmable Pushbuttons w/leds 7 Programmable LEDs Operator Control Interface EIA-232 Port Processor and

More information

D400 Substation Data Manager

D400 Substation Data Manager GE Energy D400 Substation Data Manager Software Configuration Guide SWM0066 Version 2.75 Revision 0 General Copyright Notice 2007-2009, General Electric Company. All rights reserved. The information contained

More information

SCADAPack ES. Smart RTU

SCADAPack ES. Smart RTU Smart RTU 1 Meeting the demands for high-speed distributed control and automation systems, Schneider Electric offers the SCADAPack ES as an advanced Smart RTU. Our highest performance Smart RTU built on

More information

Digital Grid Products At a Glance Protection, Substation Automation, Power Quality

Digital Grid Products At a Glance Protection, Substation Automation, Power Quality Digital Grid Products At a Glance Protection, Substation Automation, Power Quality siemens.com/digitalgrid Digital Grid Products Broadest portfolio strong brands Substation Automation, RTU s Power Quality

More information

UA-5000 Series User Manual

UA-5000 Series User Manual ICP DAS CO., LTD. UA-5000 Series User Manual IIoT Communication Server ICP DAS CO., LTD. All Rights Reserved. www.icpdas.com Warranty All products manufactured by ICP DAS are under warranty regarding defective

More information

Multilin P30 Phasor Data Concentrator

Multilin P30 Phasor Data Concentrator Multilin P30 Phasor Data Concentrator Secure high performance Phasor Data Concentrator (PDC) for wide area monitoring and dynamic disturbance analysis KEY BENEFITS Reduce deployment and operation cost

More information

Outline. 1. Introduction 2. Why Upgrading? 3. Who Is Affected? 4. How to Upgrade? 5. Benefits of the New Upgraded UR

Outline. 1. Introduction 2. Why Upgrading? 3. Who Is Affected? 4. How to Upgrade? 5. Benefits of the New Upgraded UR UR Upgrade Program Outline 1. Introduction 2. Why Upgrading? 3. Who Is Affected? 4. How to Upgrade? 5. Benefits of the New Upgraded UR 2 UR Upgrade Program 9/9/2015 1. Introduction UR Protection and Control

More information

2 PRPI General COPYRIGHT NOTICE TRADEMARK NOTICES MODIFICATION RECORD. ibox & ibox Kits Product Overview

2 PRPI General COPYRIGHT NOTICE TRADEMARK NOTICES MODIFICATION RECORD. ibox & ibox Kits Product Overview GE Digital Energy ibox* & ibox Kits PRPI043 Version 1.10 Revision 0 General COPYRIGHT NOTICE 2005, General Electric Company. All rights reserved. The information contained in this online publication is

More information

Designed, built, and tested for troublefree operation in extreme conditions

Designed, built, and tested for troublefree operation in extreme conditions SEL-2730M Managed 24-Port Ethernet Switch Designed, built, and tested for troublefree operation in extreme conditions Highest mean time between failures (MTBF) in the industry provides years of reliable

More information

Sigbert Reimann, Remote Control Forum, Datum 9. October 2013 RTU - Review and News. ABB Network Management Forum December 10, 2013 Slide 1

Sigbert Reimann, Remote Control Forum, Datum 9. October 2013 RTU - Review and News. ABB Network Management Forum December 10, 2013 Slide 1 Sigbert Reimann, Remote Control Forum, Datum 9. October 2013 RTU - Review and News ABB Network Management Forum December 10, 2013 Slide 1 Content Overview over the RTU500 series Product News New CMU in

More information

Advantech Industrial Automation Group Cui Lin

Advantech Industrial Automation Group Cui Lin Advantech Industrial Automation Group Cui Lin Target Market Smart Substation Renewable Energy Aluminium Oil & Gas Heavy Industry Petro Chemistry Transportation 2 Global Power Automation Trends Smart Substation

More information

TCP. Control and Protection Terminal Data sheet

TCP. Control and Protection Terminal Data sheet TCP Control and Protection Terminal Data sheet DSE_TCP_eng_AP No part of this publication may be reproduced by whatever means without the prior written permission of Ingeteam T&D. One of the main aims

More information

Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control

Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control Welcome to NovaTech Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control Paul Grabowski About the Author Paul Grabowski

More information

NTX Series Product Comparison

NTX Series Product Comparison NTX Function Primary design application Pole-top/pad-mount switch automation; small substation installations Small substation installations with medium serial and Ethernet port requirements Some legacy

More information

Merge physical security and cybersecurity for field operations.

Merge physical security and cybersecurity for field operations. Security Gateway Merge physical security and cybersecurity for field operations. Small form factor and wide temperature range for cabinet installation on distribution poles and in substation yards. Accelerometer,

More information

USB Interface. Power Supply. Manual Raise/Lower Operators. Communications Port (Port 1) Communications Port (Port 2)

USB Interface. Power Supply. Manual Raise/Lower Operators. Communications Port (Port 1) Communications Port (Port 2) SEL-2431 Single-Phase Voltage Regulator Control, Two 120 Vac Voltage Inputs, Eight Contact Inputs (Two 120 Vac Programmable, Four 12 Vdc Self-Whetted Programmable, and Two Dedicated), Seven Contact Outputs

More information

Features and Benefits. Certifications

Features and Benefits. Certifications PT-G503 Series IEC 61850-3/62439-3 3-port full Gigabit managed redundancy boxes Features and Benefits IEC 61850-3, IEEE 1613 (power substations) compliant IEC 62439-3 Clause 4 (PRP) and Clause 5 (HSR)

More information

SNAP PAC R-Series Controllers. SNAP PAC R-Series Controllers. Features. Description

SNAP PAC R-Series Controllers. SNAP PAC R-Series Controllers. Features. Description Features Rack-mounted industrial controller with I/O processor included. Two independent 10/100 Mbps Ethernet network interfaces One RS-232 port with handshaking, suitable for modem communication using

More information

REL 512 Connectivity With A Harris Westronics RTU Using DNP 3.0

REL 512 Connectivity With A Harris Westronics RTU Using DNP 3.0 ABB Application Note Substation Automation and Protection Division REL 512 AN-45A-99 REL 512 Connectivity With A Harris Westronics RTU Using DNP 3.0 ABSTRACT: DNP 3.0 is a popular communication protocol

More information

MIL-STD-1553 (T4240/T4160/T4080) 12/8/4 2 PMC/XMC 2.0 WWDT, ETR, RTC, 4 GB DDR3

MIL-STD-1553 (T4240/T4160/T4080) 12/8/4 2 PMC/XMC 2.0 WWDT, ETR, RTC, 4 GB DDR3 Rugged 6U VME Single-Slot SBC Freescale QorIQ Multicore SOC 1/8/4 e6500 Dual Thread Cores (T440/T4160/T4080) Altivec Unit Secure Boot and Trust Architecture.0 4 GB DDR3 with ECC 56 MB NOR Flash Memory

More information

UR Universal Relay Series

UR Universal Relay Series GE Digital Energy UR Universal Relay Series Revision 4.43 Release Notes GE Publication Number: GER-4380Rev1 Copyright 2010 GE Multilin Summary Overview GE Multilin issues the UR 4.43 release that introduces

More information

QuickSpecs. NC7771 PCI-X 1000T Gigabit Server Adapter. HP NC7771 PCI-X 1000T Gigabit Server Adapter. Overview

QuickSpecs. NC7771 PCI-X 1000T Gigabit Server Adapter. HP NC7771 PCI-X 1000T Gigabit Server Adapter. Overview Overview The NC7771 supports 10/100/1000Mbps Ethernet speeds as well as a PCI-X 64-bit/133MHz data path and it is backwards compatible with existing PCI bus architectures. Additionally, the NC7771 ships

More information

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication GE Grid Solutions DS Agile C264 Dual-bay Modular Substation Controller The DS Agile C264 substation controller is a sophisticated solution supporting multiple applications and functions for substation

More information

IEC / EN G-port Gigabit modular managed rackmount Ethernet switches STAT PWR1 PWR2 FAULT MASTER COUPLER LNK/ACT SPEED FDX/HDX

IEC / EN G-port Gigabit modular managed rackmount Ethernet switches STAT PWR1 PWR2 FAULT MASTER COUPLER LNK/ACT SPEED FDX/HDX STAT PWR1 PWR2 FAULT MASTER COUPLER LNK/ACT SPEED FDX/HDX MODE COUPLER RING PORT PORT M1 M2 M3 M4 M1 M2 M3 M4 PT-7728 PT-7728 Series IEC 61850-3 / EN50155 24+4G-port Gigabit modular managed rackmount Ethernet

More information

RTAC. SEL Real-Time Automation Controller. Integrate station control, a web-based HMI, and logging through one reliable system.

RTAC. SEL Real-Time Automation Controller. Integrate station control, a web-based HMI, and logging through one reliable system. SEL-3530-4 Real-Time Automation Controller Integrate station control, a web-based HMI, and logging through one reliable system. Features and Benefits Integrated Security As with its bigger brother, the

More information

Ovation Ethernet Link Controller Module Data Sheet

Ovation Ethernet Link Controller Module Data Sheet Ovation Ethernet Link Controller Module Features: Provides native Ethernet connectivity capability at the I/O level Enables faster, more efficient integration of robust data from third-party devices Dedicated

More information

PT-7710 Series. IEC / EN G-port Gigabit modular managed rackmount Ethernet switches. Introduction. Specifications

PT-7710 Series. IEC / EN G-port Gigabit modular managed rackmount Ethernet switches. Introduction. Specifications STAT PWR1 PWR2 FAULT MASTER COUPLER LNK/ACT SPEED FDX/HDX MODE COUPLER RING PORT PORT 2 4 6 8 1 3 5 7 2 1 M2 M1 M1 M2 PT-7710 PT-7710 Series IEC 61850-3 / EN50155 8+2G-port Gigabit modular managed rackmount

More information

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS e & Designed GSM / GPRS ETHERNET SMTP HTTP MODBUS TCP-IP USB MODBUS RTU THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS www.seneca.it taly 100% ad I in GSM/GPRS DATALOGGER WITH BUILT-IN

More information

2 NOVATECH. This page is intentionally left blank.

2 NOVATECH. This page is intentionally left blank. NovaTech Orion I/O 2 NOVATECH This page is intentionally left blank. ORION I/O 3 NovaTech Orion I/O Overview NovaTech Orion I/O is an extension of the family of OrionLX Automation Platforms for substation

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iopac 8600 Series Rugged modular programmable controllers Features and Benefits Modular CPU/power/backplane design that supports 85M/86M modules Tag-centric design with ready-to-run services Supports C/C++

More information

Ovation Compact Controller

Ovation Compact Controller Ovation Compact Controller Model OCC100 Features Secure, reliable and mission-critical control capability for remotely located plants or processes Modular I/O base design for flexible placement within

More information

HP NC7771 PCI-X 1000T

HP NC7771 PCI-X 1000T Overview The NC7771 supports 10/100/1000Mbps Ethernet speeds as well as a PCI-X 64-bit/133MHz data path and it is backwards compatible with existing PCI bus architectures. This range of features enables

More information

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay Bus Differential and Breaker Failure Relay A Powerful Solution for Busbar Differential Protection Features and Benefits Select the for the differential protection of busbar systems with up to 18 terminals.

More information

PROFILINK/908. Modicon S908 Remote I/O To Profibus DP Gateway Process Computer Technology, Inc.

PROFILINK/908. Modicon S908 Remote I/O To Profibus DP Gateway Process Computer Technology, Inc. Modicon S908 Remote I/O To Profibus DP Gateway www.profibus.com 2005 Process Computer Technology, Inc. Tables... 1 Table of Figures... 1 Table of Tables... 1 Revision History... 2 Acknowledgements... 3

More information

QuickSpecs. HP NC6170 PCI-X Dual Port 1000SX Gigabit Server Adapter. Overview. Retired

QuickSpecs. HP NC6170 PCI-X Dual Port 1000SX Gigabit Server Adapter. Overview. Retired The is a dual port fiber Gigabit server adapter that runs over multimode fiber cable. It is the first HP server adapter to combine dual port Gigabit Ethernet speed with PCI-X bus technology for fiber-optic

More information

LineScope. Smart Power Monitor. Bulletin DB50C18. US Patent Nos , , and B2

LineScope. Smart Power Monitor. Bulletin DB50C18. US Patent Nos , , and B2 Bulletin DB50C18 LineScope Smart Power Monitor US Patent Nos. 9664710, 9746498, and 9810720B2 14000 Rt. 993, Trafford, PA 15085 p 724-864-4177 f 724-864-9040 e sales@cleavelandprice.com The LineScope Overview

More information

Interface Adapter Card. Part Number

Interface Adapter Card. Part Number Features 32-bit processor Built-in diagnostics One dedicated Opto 22 remote I/O port (2-wire RS-485 with interrupt capability) Three RS-232 or RS-485 (2-wire or 4-wire) serial ports, with baud rates up

More information

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 METRIC SPECIFICATIONS FOR VME BUS COMPUTER (FIELD TERMINAL VME BUS PROCESSOR ASSEMBLY) N.J. Specification No. Effective Date:

More information

SMART PROGRAMMABLE RELAYS

SMART PROGRAMMABLE RELAYS CONTROL LOGIC SMART PROGRAMMABLE RELAYS c3controls line of compact programmable relays are integrated, and ready to use, with a wide range of programmable functions. With up to 250 lines of ladder logic

More information

Multilink. Ethernet Communications for Industrial Automation, Power Utility, and Traffic Control markets. Multilin

Multilink. Ethernet Communications for Industrial Automation, Power Utility, and Traffic Control markets. Multilin Multilink Ethernet Communication switches Ethernet for Industrial Automation, Power Utility, and Traffic Control markets Key Benefits The MultiLink family is a line of Industrial and Substation Hardened

More information

Fix serial communications not functioning after reboot when the station number is set to iptables Fix iptables.

Fix serial communications not functioning after reboot when the station number is set to iptables Fix iptables. Sixnet IPm Firmware Revision History Note: IPm firmware versions are of the form major.minor.buildnumber. A letter X will be appended in the case of unreleased experimental versions. Other letters may

More information

SICAM RTUs Ready for the Future

SICAM RTUs Ready for the Future SICAM RTUs Ready for the Future, RC-AT EM DG PRO LM siemens.com SICAM RTUs News Overview SICAM A8000 Series SICAM Engineering SICAM AK3 Page 2 SICAM RTUs News Overview SICAM A8000 Series SICAM Engineering

More information

GE Multilin 350 Feeder Protection Relay Specifications

GE Multilin 350 Feeder Protection Relay Specifications GE Multilin 350 Feeder Protection Relay Specifications The feeder protection relay shall provide primary protection of medium voltage distribution feeders. The relay shall be equipped with the following

More information

UA Series IIoT Communication Server

UA Series IIoT Communication Server UA Series - IIoT Communication Server UA Series IIoT Communication Server UA-5231 UA-5231M UA-5231M-3GWA UA-5231M-4GE UA-5231M-4GC Features OPC UA Server MQTT Client Service MQTT Broker Inside ARM CPU,

More information

Development of remote monitoring and control equipment with advanced communication functions

Development of remote monitoring and control equipment with advanced communication functions Development of remote monitoring and control equipment with advanced communication functions Ayuchi Kurosu, Nobukazu Teraoka, Keiichi Ohama [Summary] We have developed the NH Telemeter series of equipment

More information

SEL Real-Time Automation Controller (RTAC)

SEL Real-Time Automation Controller (RTAC) SEL Real-Time Automation Controller (RTAC) Product Family Rugged, deterministic, and reliable automation controllers for any environment 1 ms deterministic processing intervals support critical protection

More information

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch SEL-2730M Managed 24-Port Ethernet Switch Reliably Control and Monitor Your Substation and Plant Networks Features and Benefits Tough Designed, built, and tested for trouble-free operation in extreme conditions,

More information

D20 Status Input Module

D20 Status Input Module GE Digital Energy D20 Status Input Module Overview The D20 Status module is composed of two detachable modules, WESTERM D20 S and WESDAC D20 S. The bottom module, WESTERM D20 S, is where all field wirings

More information

CLIQ Remote - System description and requirements

CLIQ Remote - System description and requirements CLIQ Remote - System description and requirements 1. Introduction CLIQ Remote - Access at a distance CLIQ Remote is an electromechanical lock system with an additional level of security and flexibility,

More information

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client User Manual V1.0.0 Table of Contents Overview... 1 1.1. Specification... 1 1.2. Dimensions... 2 1.3. Connector pinouts... 3 1.4. Restoring factory default... 3 1.5. LED indicator... 3 1.6. CR1225 battery...

More information

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations siemens.com/siprotec5 SIPROTEC 5 Table of content Introduction New functions of V7.8 SIPROTEC 5 - the core of Digital Substation

More information