Installation and Operation Manual for the D1154 Programmer for DigiCom NVM

Size: px
Start display at page:

Download "Installation and Operation Manual for the D1154 Programmer for DigiCom NVM"

Transcription

1 Installation and Operation Manual for the D1154 Programmer for DigiCom NVM For D1154 Version 4.05 Dycon Ltd Cwm Cynon Business Park Mountain Ash CF45 4ER UK Tel: +44 (0) Fax: +44 (0)

2 INDEX Section Subject Page 1 Introduction 3 2 Installation 3 3 Operation 5 4 Programming Numbers 7 5 Input Settings 8 6 Monitoring and Outputs 9 7 Reading and Comparing NVMs 11 8 Viewing and Printing Files 12 9 Loading and Saving Files to Disk DTMF Fast Format Protocol Settings, Options Hex Editor System Information Troubleshooting, Help and Web Site 17 Appendix 1 D0354 and D0355 Programming Sockets 19 Appendix 2 Program Launcher 20 Appendix 3 Glossary of Terms 24 D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 24 Page 2 of

3 1. Introduction The D1154 NVM Programmer is used to program the operating parameters of the DigiCom, using a local NVM Programming Socket. The D1154 NVM Programmer has been designed to operate on a PC computer using Windows 95, 98, ME, NT, 2000, XP or later operating systems. The D1154 is supplied with an NVM Programming Socket. Part Numbers Fig. 1 Part number D0354 D0355 D1055 D1100 D1101 D0730 D0402 Description NVM Programming Socket with lead and plug + PSU (for a PC s parallel port only) NVM Programming Socket + USB lead (for a PC s USB port only) Pack of 10 NVM ICs DigiCom DigiCom for control panels with plug-on connectors Security ADSL (broadband) filter Products CD containing this programmer and manual This manual uses many abreviations. See the Glossary of Terms section on page 24 of this manual for their meanings. Many of the computer and communication options available in DigiCom may be new to some users. If you still have problems or questions after reading this manual help is at hand. See the Troubleshooting and Help section for sources of additional information. 2. Installation When supplied, the D1154 GSM DigiCom Programmer includes: a) the D1154 software installation programme supplied on CD; b) a D0355 NVM programming socket. Everything that you require is supplied for an NVM programmer connected to your PC. 1. With the programming socket disconnected from the PC, power up the PC, enter the password etc. Ensure that the boot-up sequence has completed. 2. Very Important: Before installing this software it is essential that all older versions are first removed from the PC. To uninstall, use the Windows utility. Press the Windows START menu, select the SETTINGS, CONTROL PANEL option. Then select the ADD/REMOVE PROGRAMMES icon. From the list, select the programme to be uninstalled, then press the UNINSTALL button. Follow screen instructions. Repeat for all older versions of this software. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 24 Page 3 of

4 2. Installation (cont d) Delete older folders. Double-click on the MY COMPUTER icon to open it. Double-click on the C hard disk to open it. Delete the folder named Dycon by dragging it to the Recycle Bin, or right-click on it, then select the DELETE option. Repeat the DELETE action for folders called GSMREMOT and REMOTE. 3. Install the programmer software on the PC. First, ensure that all older versions of this software are removed from the PC. The D0402 Products CD contains the installation software and manuals for all of the Dycon programmers. A program launcher will also be installed. See Appendix 2. To install the D1154 software, simply run SETUP.EXE from the CD or select the D1154 programmer using the browser on the CD. Then follow the on-screen instructions. When installation is complete, remove the CD and store in a cool dry place. The installer will install all of the files for the D1154 programmer onto the PC s hard disk into the PROGRAM FILES folder. A folder called DYCON will be added that contains all Dycon product software. The D1154 programmer will be installed in the DYCON \ D1154 DIGICOM PROGRAMMER folder. 4. Connect the NVM programming socket. Two types are available. Refer to Table 1. The D0355 programming socket is supplied with a lead that connects to the PC s USB port. This programming socket can be used on Windows 98 or any more recent Windows version. When this programming socket is used, the D1154 programmer software must be v or later. See Appendix 1 for details. The earlier D0354 programming socket connects to the PC s printer (or LPT) port. This programming socket can be used with the D1154 programmer software but can only be used on Windows 95, 98, 98SE or ME. See Appendix 1 for details. Note 1: When the D0355 programming socket is connected and is first detected by Windows, the USB driver software is located and installed. Some versions of Windows do not contain suitable USB drivers and will display a screen message. In this case, open the D0402 Products CD, open the DYCONDATA folder, open the D0355 folder, open the USB DRIVERS folder, select the FTDIBUS.INF file and follow screen instructions. Note 2: Where Windows XP is in use and a firewire port or some other peripherals are fitted, then the PC may not always recognise the D0355 programming socket on the USB port. If the programming socket is not detected by the PC: - From the START menu, select the CONTROL PANEL, then select PERFORMANCE & MAINTENANCE. - Select SYSTEM, then select the HARDWARE tab, then press the DEVICE MANAGER button. - Double-click PORTS, then double-click the USB SERIAL PORT, then select the PORT SETTINGS tab. - Press the ADVANCED button and locate the COM PORT NUMBER box. - Where the COM PORT NUMBER is 16 or lower then close all windows by their OK or CLOSE buttons. - Where the COM PORT NUMBER is not displayed or a number of 17 or greater is displayed then choose a port number that is not used. The port number chosen must be 16 or lower. - Click to highlight it. Click the OK button. Close all windows by their OK or CLOSE buttons. 5. Start the D1154 program by double-clicking on the DYCON PROGRAMS icon that is in the START menu, PROGRAMS option. Alternatively, the program can be started using the shortcut called DYCON PROGRAMS that has been placed on the Windows desktop. This will start the program launcher. See Appendix 2. Press the D1154 programmer button. The programming windows are best seen on displays set to 800 x 600 resolution (or larger) at 16 colours (or greater). Adjust the setup options for the NVM programmer software as described in Section 11, Settings and Password. Press the CANCEL button to close the D1154 programmer. Note: The program launcher may be left running on the desktop or may be closed seperately. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 24 Page 4 of

5 Windows SE ME NT 2000 XP D1154 Programming Software No Yes Yes Yes Yes Yes Yes Yes D0354 NVM No Parallel Parallel Parallel Parallel No No No Programming LPT Port LPT Port LPT Port LPT Port Socket D0355 NVM Programming Socket No No USB Port USB Port USB Port USB Port USB Port USB Port Table 1 Menus Open Save as Inputs Write File Name Numbers Monitoring Read Check 3. Operation Fig. 2 - top of the main window with the menus and the buttons on the toolbar Start the D1154 program by double-clicking on the DYCON PROGRAMS icon that is in the START menu, PROGRAMS option. Alternatively, the program can be started using the shortcut called DYCON PROGRAMS that has been placed on the Windows desktop. This will start the program launcher. See Appendix 2. Press the D1154 programmer button. The TITLE screen (see Fig 1) will appear followed by the main window with the menus and toolbar at the top. See Fig 2. The main window has all controls available by menu, but for ease of use several shortcut buttons are provided on the toolbar. The functions of all the menu commands and these buttons are described in the following pages. To close the D1154 NVM programmer program and return to Windows, do any one of the following standard Windows closure actions: 1. Double-click the icon in the top left corner of the main window 2. Click the icon in the top left corner of the main window to get a drop-down menu, select CLOSE 3. Select the FILE menu, EXIT command 4. Click the X box in the top right corner of the main window 5. On the keyboard, press and hold the Alt key, then press the F4 key D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 24 Page 5 of

6 3. Operation (cont d) The Button and Menu commands available on the main window are listed here and refer to the sections on the following pages (see Table 2). Button Menu Section Open / Save File, New File, Open File, Save File, Save As File, Print File, Exit Numbers, Input, Monitor Read, Write, Compare Edit, Cut Edit, Copy Edit, Paste Edit, Delete View, Number View, Inputs View, Monitoring View, Hex Edit NVM, Read NVM, Program NVM, Compare Settings, Programmer Settings, Toolbar Settings, Printer 9. Loading and saving files 9. Loading and saving files 9. Loading and saving files 9. Loading and saving files 8. Viewing and printing files 3. Operation See Windows manual See Windows manual See Windows manual See Windows manual 4. Programming numbers 5. Input settings 6. Monitoring and outputs 12. Hex editor 7. Reading and writing NVMs 7. Reading and writing NVMs 7. Reading and writing NVMs 11. Settings 11. Settings 11. Settings To read from an NVM Table 2 1. Install the D1154 software. See Section 2. Connect a D0354 or D0355 programming socket. See Section 2. Adjust the setup options for the programming socket. See Section 11. The D0355 programming socket includes LEDs to indicate operation. See Appendix Fit the NVM into the programming socket. See Fig Press the READ button (see Fig 2) or use the NVM menu, READ command. 4. The NVM data may now be read from each of the screens. Select each as required using the toolbar buttons or select from the VIEW menu. See Sections 4, 5, 6 and 13. To program an NVM 1. Install the D1154 software. See Section 2. Connect a D0354 or D0355 programming socket. See Section 2. Adjust the setup options for the programming socket. See Section 11. The D0355 programming socket includes LEDs to indicate operation. See Appendix Fit the NVM that you intend to program into the programming socket. The type must be 93C46 or Dycon D1055. See Fig Select each screen as required using the toolbar buttons or select from the VIEW menu. Program the data required into each screen. See Sections 4, 5, 6 and 13. Note: The minimum programming required to make an NVM to test a system is to enter the telephone number that DigiCom will dial when reporting to an ARC then program an account number (chip number). All other settings may be left at the default values. 4. Press the WRITE button (see Fig 2) or use the NVM menu PROGRAM command. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 24 Page 6 of

7 3. Operation (cont d) DigiCom Reporting When DigiCom is triggered it will initially attempt to dial and report to telephone number 1 using the account number (or chip number) to identify the DigiCom. DigiCom will use the DTMF Fast Format protocol to report to the receiving equipment at the ARC. Should this first attempt be unsuccessful, DigiCom will repeat the attempt to telephone number 2 after a preset pause. Should this second attempt be unsuccessful, DigiCom will repeat the attempt to telephone number 3 after a preset pause. Where a second or third telephone number has not been programmed, the repeat attempts are made in turn to the telephone numbers that have been programmed. After 3 attempts to report to a number have failed, the Fail to Communicate state will operate the fault relay. In accordance with PSTN approval requirements, a maximum of 5 attempts will be made to each number. No further dialling attempts are made once the alarm message has been successfully passed to an ARC receiver. If a Comms Successful output is specified in the NVM, this will occur at the same time. 4. Programming Numbers Select the NUMBERS button (see Fig 2) or use the VIEW menu, NUMBERS command to reach the CALLING INFO screen. This is where the numbers that the DigiCom will call are programmed. Fig. 3 The following parameters can be set from this window. Note that at least one telephone numbers must be entered. 1 PSTN 1 - this is the first telephone number at the ARC that the DigiCom will call via the PSTN. A telephone number must be entered here. Enter the digits that are to be dialled. Do not put spaces between the numbers. If you require detection of a dial-tone after dialling a prefix digit, insert the character D after the prefix. If you want a fixed 4-second dial pause, insert the character A at the point that you require the pause. E.g. 9D132A , This will grab the telephone line, dial 9 (prefix for an outside line), wait until a dial-tone is detected, then dial 132 to access the Mercury network, wait 4 seconds then dial See Section 3, DigiCom Reporting for a description of the dialling sequence. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 24 Page 7 of

8 4. Programming Numbers (cont d) 2. PSTN 2 - this is the second telephone number at the ARC that the DigiCom will call via the PSTN. See PSTN 1 for details. The entry of a second telephone number here is optional. 3. PSTN 3 - this is the third telephone number at the ARC that the DigiCom will call via the PSTN. See PSTN 1 for details. The entry of a third telephone number here is optional. 4. PSTN dialling - select dialling type from Pulse dial, MF (tone) dial, or MF with 3-way calling. Where the DigiCom shares its telephone line with other equipment, e.g. a fax machine, and 3- way calling is available from the telecomms supplier, this feature should be selected. Correct operation of 3-way calling requires the PSTN wiring to the DigiCom to be as recommended in the DigiCom Installation Manual. Three-way calling and correct wiring will enable a call to the other equipment, e.g. a fax machine, to be interrupted should the DigiCom need to send an alarm call on the telephone path. Note that 3-way calling may attract an additional charge from the telecomms supplier. 5. Account Number - sets the account number (sometimes called the chip number) that identifies this DigiCom site (normally 4 digits). An account number must be entered here. 6. Increment - this button simply increments the account number shown and is helpful if you are programming several NVMs with sequential numbers. 5. Input Settings Select the Inputs button (see Fig 2) or use the VIEW menu, INPUTS command to reach the Input Settings screen. The input screen sets the configuration of DigiCom inputs. The setup parameters are simply selected by clicking in the boxes relative to each particular input. Fig. 4 The following input parameters can be programmed from this window: 1. Inverted changes the input response from a positive applied start to a positive removed start. 2. Channel (1 to 8) - enter a number in each box (1-8) to determine which channel of the transmission will be controlled by which input. Active channels will be triggered when a particular input is activated. Enter 0 for those inputs that will not trigger a transmission to an ARC. Where a D1101 Plug-on DigiCom is used, it may be necessary to program that different channels are triggered from the 8 inputs. This feature allows any channel to be triggered by any input. 3. Restore selects those inputs that are required to send a restore signal to the ARC once the input has changed back to its normal state. 4. Open/Close - select those inputs that report open and closings instead of alarm and restores. When this is selected, both open and close will always be reported. The Restore selection for this input will have no effect. 5. Comms Success - select those channels that will make the output relay operate for a period after every successful transmission. See Comms Success on page 9. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 24 Page 8 of

9 5. Input Settings (cont d) 6. Abort selects which channel will signal Alarm Abort to the ARC. This feature enables older alarm systems to comply with the ACPO false alarms policy (see Glossary of Terms). The same channel should have its corresponding input disabled or no connection made to that input (See Channels, Fig 4). If the Alarm Abort information is not required, select the Off position (next to No.1). 7. Delayed Reporting selects a 20 second delay between triggering (and restoral) of channel 3 and sending the transmission to the ARC. This feature can be used to reduce false alarms by allowing the alarm system user to reset an alarm within 20 seconds and avoid a channel 3 call to the ARC. Example: With the delay selected and set to 20 seconds, an input signal up to 19 seconds will not start a transmission. If the input signal is applied and stays applied for 21 seconds or longer, then the alarm transmission will be triggered. 6. Monitoring and Outputs Select the MONITORING button (see Fig 2) or use the VIEW menu, MONITORING command to reach the Monitoring & Outputs screen. Monitoring is used by the DigiCom to ascertain whether the PSTN signaling path is faulty. Fig. 5 This screen has three parts. The top right quadrant of the window sets the Line Monitor for the type of monitoring. The bottom left quadrant of the window sets the OUTPUTS. The top right left of the window sets the TEST CALLS and other timing functions. The following pages describe each in detail. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 24 Page 9 of

10 Line Monitor The top right quadrant of the window sets the Line Monitor for the type of monitoring on the PSTN line (see Fig 5) Hour DC Voltage Check, continuously checks for a DC voltage on the PSTN line that comes from the exchange equipment. If it is below approx. 3.5 volts or absent, then the line monitor will trigger a PSTN Line Fault Hour Off-hook Detect, continuously checks for another phone (or fax, modem etc.) on the same PSTN line being off-hook. If it is, it may inhibit DigiCom from making a telephone call. If the off-hook state is detected, the line monitor will trigger a PSTN Line Fault. This option should only be selected for PSTN lines that have no other equipment connected to the PSTN line and no other equipment connected the DigiCom A1 and B1 terminals Hour Ringing Detect, continuously checks for incoming ringing on the PSTN line. Incoming Ringing may inhibit DigiCom from making a telephone call. If incoming ringing is detected, the line monitor will trigger a PSTN Line Fault. This option should only be selected for PSTN lines that are supplied as Incoming Ringing Barred (ICB), i.e. they shouldl never have ringing on them. PSTN Line Monitor Hour Dial Tone Detect, periodically checks the PSTN line by listning for dial tone, dialling the digit 5 and ensuring that the dial-tone disappears. An absent dial tone can inhibit DigiCom from making a telephone call. If the dial tone test fails, then the line monitor will trigger a PSTN Line Fault. The period is selected by Tests, 2 and 3 below. 5. Defeat Line Monitor Output - select this to disable the line monitor output on the D1101 Plug-on DigiCom. Note that this control has no effect on the D1100 DigiCom. 6. Dedicated Line selects the recommended combination of options when DigiCom is using a PSTN line that has been provided exclusively for the alarm system where no other equipment will use the same PSTN line. Other equipment may be a telephone, a fax, a modem etc 7. Shared Line selects the recommended combination of options when DigiCom is sharing a PSTN line with other equipment. A series connection to the shared equipment is recommended. See DigiCom Installation Manual. Note: it is recommended that the monitoring for a shared line is not changed from the pre-set parameters, otherwise a line fault may occur when the PSTN line is in use by other equipment, e.g. a telephone, a fax, a modem etc Tests The top left quadrant of the window sets the Test Calls for regular tests calls to the ARC and the various timing functions (see Fig 5). 1. Test Call Interval - sets the period in hours between automatic test calls. A setting of 0 turns off all automatic test calls. The period between test calls is set in periods of hours, 1 to 99. Test calls are only sent after the Test Call Interval has elapsed following the last call (the last call may be alarm, open close, test etc ). 2. Unset Dialtone Test Interval - sets the period (0 to 99 minutes) between dial-tone tests when the system is set. See Line Monitor, 4 above. A value of 0 will switch off dial-tone testing during the unset period. It is recommended that this feature is not enabled on a shared telephone line. 3. Set Dialtone Test Interval - sets the period (0 to 99 minutes) between dial-tone tests when the system is unset. See Line Monitor, 4 above. A value of 0 will switch off dial-tone testing during the set period. 4. Comm Fail Time - sets the time in seconds that the output relay will be operated when a communication to the ARC is un-successful. See Output 1 and Comm Success Time - sets the time in seconds that the output relay will be operated when a communication to the ARC is successful. See Output 1 and 2. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 10

11 Outputs The bottom left quadrant of the window sets the OUTPUTS relay functions (see Fig 5) for output 1 and 2. Only one of the following may be selected: Line Monitor, Comms Fail, Comms Success. 1. Line Monitor - select to make the output relay operate in response to the line monitor output. 2. Comms Fail - select to make the output relay operate for a period after every failure to make a successful transmission. The period is set by the Comm Fail Time (see Tests, 4). All failed transmissions including test calls will operate the relay. 3. Comms Success - select to make the output relay operate for a period after every successful transmission for selected channels. See Comms Success on page 11. The period is set by the Comm Success Time (see Tests, 5). All successful transmissions including test calls will operate the relay. 3. Comms in Progress 4. Inverted - makes the output relay normally energised. The functions above will make the relay de-energise when operated. 5. Latched - makes the output relay stay in the operated state until the DigiCom is reset or has power removed and replaced. When this option is selected the Comm Fail Time and Comm Success Time (see Tests, 4 and 5) are not used. 7. Reading and Comparing an NVM Ensure that the Programming Socket is connected to the computer as described in the Installation, Section 2. Using the Read, Write & Compare buttons or the NVM menu options on the main screen, follow the instructions below. Fitting an NVM into the Programming Socket Lift the lever on the NVM programming socket. Fit the 8 pin NVM into the lower half of the socket (the end nearest the lever). Ensure that the end of the NVM marked with a dot or line identifying Pin 1 is towards the upper half of the socket. Lower the lever to lock the NVM in the socket. See Fig 6. Fig. 6 To read from an NVM using the Programming Socket 1. Install the D1154 Programmer software. See Section 2. Connect a Programming Socket. See Section 2. Adjust the setup options for the Programming Socket. See section 11. Note: The D0355 Programming Socket includes LEDs to indicate operation. See Appendix Fit the NVM into the programming socket. 3. Press the Read button or use the NVM menu, Read command. See Fig 2. When the read process is complete, the Prom read OK message will be displayed. If the NVM contains data that is invalid for DigiCom operation then the NVM Invalid Data message is displayed when the NVM is read. In addition a red warning triangle will flash on the toolbar. Invalid Data means information that DigiCom requires is obviously incorrect, e.g. no telephone numbers, an account number that has letters as well as numbers, a blank NVM etc. 4. The NVM data may now be read from each of the screens. Select each as required using the toolbar buttons or select from the View menu. See Sections 4, 5, 6 and 13. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 11

12 To program an NVM using the Programming Socket 1. Install the D1154 programmer software. See Section 2. Connect a programming socket. See Section 2. Adjust the setup options for the programming socket. See Section 11. Note: The D0355 programming socket includes LEDs to indicate operation. See Appendix Fit the NVM that you intend to program into the programming socket. 3. Select each screen as required using the toolbar buttons or select from the View menu. Program the data required into each screen. See Sections 4, 5, 6 and 13. Note: The minimum required to test a system is: Program the telephone numbers that DigiCom will dial when reporting to an ARC, then Program an Account Number (the Chip Number). 4. Press the Program button or use the NVM menu Program command. See Fig 2. There are many other programming options. The above will program an NVM with the default values which will allow the Dualcom to operate in most cases. If the NVM already contains some data, the NVM Not Blank message is displayed before programming commences. After 1-2 seconds the Prom programmed OK message will be displayed. The Prog Fail message will be displayed if an NVM can not be programmed. Prog Fail often indicates that there is insufficient power available to program the NVM. Check the connections from the Programmer PSU. Comparing an NVM with the screen Parameters If you wish to compare the information held in the NVM with that of the programmer, click on the Compare button (see Fig 2) or use the NVM menu Compare command. If the data held in the NVM is identical with that held in the programmer, the Compare OK message is displayed. If any bit of data in the NVM differs from that on the Programmer screen, then a message will be displayed together with the location of that data in the NVM plus the NVM data and the differing data. When the data has been noted, press the OK button to see the next location that is different. Press the Cancel button to end the compare display. 8. Viewing and Printing Files Open a.prm file as described in Section 9 or read an NVM fitted in the programming socket. This will load a NVM file into the Programmer. All settings may then be viewed by selecting each screen using the toolbar buttons or by the menus as described on the preceding pages. Use the File menu Print command to print a copy of the current setup condition. This text file will represent all the settings within the Programmer at this time. 9. Loading and Saving Files to Disk Files that are created on the D1154 Programmer can be saved to disc as.prm files. This is particularly useful because a library of masters can then be stored on disc for access when required. Use the Open and Save file buttons (see Fig 2) exactly as with files in any other Windows program. Name each file to identify it to a particular site with the extension PRM, e,g, MASTER1.PRM. See Fig 7. The Save As command is available on the File menu for creating new files. Most users program an NVM as a Master NVM containing their normal setups, telephone numbers etc This may be done by saving the Master NVM as a file on the PC. Making a new NVM requires opening the Master NVM file, entering the required Account Number and pressing the NVM Write button. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 12

13 9. Loading and Saving Files to Disk Fig DTMF Fast Format Table 3 shows the full range of data that is sent from a DigiCom every time it sends a transmission to the ARC receiving equipment using the DTMF Fast Format protocol. A transmission consists of 8 channels of data followed by the one test channel. Each channel carries a single digit. The digits that can be carried by the 8 channels are shown in Table Data. The digit that can be carried by the Test channel is shown in Table 3 T Data. 1-8 Data T Data Meaning 1 New alarm event 2 Opening event 3 New alarm restoral 4 Closing event 5 No event, input is in the quiescent state. Alarm channel = No alarm Open/close channel = Closed, Set 6 No event, input is in the active state. Alarm channel = Alarm Open/close channel = Open, Unset 7 Quiescent 8 Low Battery new event and state 9 Test Event or Low Battery restoral Table Settings Programming Socket From the menu bar select Settings, then Programmer. The available parallel (or printer) LPT ports and USB ports that can be used for the D0354 or D0355 programming sockets will be listed. See Fig 8. The D0354 programming socket connects to the PC s printer (or LPT) port. This programming socket can only be used on Windows 95, 98, 98SE or ME. When the Windows version is not 95, 98, 98SE or ME, thepc s printer (or LPT) port(s) will not be listed in the Settings menu. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 13

14 11. Settings (cont d) The D0355 programming socket is supplied with a lead that connects to the PC s USB port. This programming socket can be used on Windows 98 or any more recent Windows version. Also, the Pprogrammer software must be v or later. Fig 8 Options There are several windows and features that are not enabled when the programmer is first installed. The Settings menu, Options allow these to be enabled or disabled as required. See Fig 5. Fig 9 The following parameters can be set from this window: 1. Hex Edit - the Hex Editor window is used when accessing the NVM for editing in Hexadecimal mode. Refer to Section 12. To add Hex Edit to the View menu, click on the tick-box to so that the tick is visible. To remove Hex Edit from the View menu, click on the tick-box to so that the tick is not visible. 2. System - the System Area window is used when accessing the System Information area of the NVM. Refer to Section 13. To add System to the View menu, click on the tick-box to so that the tick is visible. To remove System from the View menu, click on the tick-box to so that the tick is not visible. 3. Search for USB Programming Socket on Startup - the System Area window is used when accessing the System Information area of the NVM. Refer to Section 13. To enable this feature, click on the tick-box to so that the tick is visible. To disable this feature, click on the tick-box to so that the tick is not visible. 12. Hex Editor Select the View menu, Hex Edit command to reach the Hex Editor screen. This window is used when accessing the NVM for editing in Hexadecimal mode. When supplied, the programmer does not allow the user to select the Hex Editor from the View menu. To make the Hex Edit option appear on the View menu, select Settings, then Options. Refer to Section 11. WARNING Incorrect settings in this window can adversely affect or stop the operation of the DigiCom. Many parameters are defined by the PSTN approval standards and must NOT be changed. You are advised that changes to parameters should only be made if you fully understand the consequences of those changes. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 14

15 12. Hex Editor (cont d) Fig 10 Hex Editor screen The following functions are available in this window: 1. Address Hex - enter the address in hexadecimal for the byte that will be edited, then press the keyboard Enter or Carriage Return key to select that address. Note: decimal addressing may be more convienent for some address applications. Selection of an address may also be achieved by clicking with the mouse in the required address box to highlight that address. 2. Address Decimal - enter the address in decimal for the byte that will be edited, then press the keyboard Enter or Carriage Return key to select that address. Note: hexadecimal addressing may be more convienent for some address applications. Selection of an address may also be achieved by clicking with the mouse in the required addressbox to highlight that address. 3. Data Hex - displays the byte of data contained in the selected address in hexadecimal. To change the data, enter the required value, then press the keyboard Enter or Carriage Return key to change the data. The address highlighted will move to the next address. 4. Data Decimal - displays the byte of data contained in the selected address in decimal. To change the data, enter the required value, then press the keyboard Enter or Carriage Return key to change the data. The address highlighted will move to the next address. 5. Data Binary - displays the byte of data contained in the selected address in binary. To change the data, enter the required value, then press the keyboard Enter or Carriage Return key to change the data. The address highlighted will move to the next address. 13. System Information Select the View menu, System command to reach the Edit System Information screen. This window is used when accessing the System Information area of the NVM. When supplied, the Programmer does not allow the user to select the System Area from the View menu. To make the System option appear on the View menu, select Settings, then Options. Refer to Section 11. WARNING Incorrect settings in this window can adversely affect or stop the operation of the DigiCom. Many parameters are defined by the PSTN approval standards and must NOT be changed. You are advised that changes to parameters should only be made if you fully understand the consequences of those changes. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 15

16 13. System Information (cont d) Fig 11 Edit System Information screen The following PSTN Tone functions can be programmed from this window: 1. Dialtone Frequency Min - defines the lower edge of the band of frequencies that may be detected as a dialtone prior to dialling a number on the PSTN. 2. Dialtone Frequency Max - defines the upper edge of the band of frequencies that may be detected as a dialtone prior to dialling a number on the PSTN. 3. Dialtone Detect Time - the period for which dialtone must be present before detection is successful. This may be continuous or pulsed. 4. Blind Dial - select this to make Dualcom dial on the PSTN after the Wait period without having to detect a dialtone. 5. First Handshake Frequency Min - defines the lower edge of the band of frequencies that may be detected as the first handshake frequency of the Fast Format alarm transmission protocol. 6. First Handshake Frequency Max - defines the upper edge of the band of frequencies that may be detected as the first handshake frequency of the Fast Format alarm transmission protocol. 7. Second Handshake Frequency Min - defines the lower edge of the band of frequencies that may be detected as the second handshake frequency of the Fast Format alarm transmission protocol. 8. Second Handshake Frequency Max - defines the upper edge of the band of frequencies that may be detected as the second handshake frequency of the Fast Format alarm transmission protocol. 9. Acknowledge Frequency Min - defines the lower edge of the band of frequencies that may be detected as the acknowledge (or kissoff) frequency of the Fast Format alarm transmission protocol. 10. Acknowledge Frequency Max - defines the upper edge of the band of frequencies that may be detected as the acknowledge (or kissoff) frequency of the Fast Format alarm transmission protocol. 11. Attempts to Fail - the number of reporting attempts that will be made on the PSTN path from one triggering action aftwer which the fault relay will operate. 12. Attempts to Abort - the maximum number of reporting attempts that will be made on the PSTN path from one triggering action. 13. Wait Between Attempts - the time from the end of a failed reporting attempt on the PSTN path to the start of the next attempt on the DigiCom PSTN path. 14. Dial Pause - the time (in seconds) that an A in the telephone number will cause a pause in dialling the numerical digits. 15. Dialtone Wait - the time (in seconds) that the DigiCom will wait for a dialtone after grabbing the telephone line. After this period, the unit will dial anyway if the Blind Dial box is selected, else the reporting attempt will fail. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 16

17 13. System Information (cont d) 16. Pulse Dial Make Time - a time in milli-seconds for the pulse (loop-disconnect) dialling contact make period. 17. Pulse Dial Break Time - a time in milli-seconds for the pulse (loop-disconnect) dialling contact break period. 18. Interdigit Pause - a time in milli-seconds for the pulse (loop-disconnect) dialling contact make period between successive dialled digits. 19. DTMF On Time - a time in milli-seconds for the DTMF (tone) dialling on period. 20. DTMF Off Time - a time in milli-seconds for the DTMF (tone) dialling off period. 21. Handshake Wait - a time in seconds from the start of dialling that the DigiCom will wait for the handshake from the ARC receiver, after which the call attempt will fail. 22. NVM Identifier - identifies the NVM as containing the DigiCom data. The options are: 31 = Scantronic Scancom 8400, 8440, 9056 Digital Communicators. When using the Scantronic 7200 or 7300 programmer, access to the Manufacturers Data area (0097 to 0127) is inhibited. 32 = Scantronic Scancom 8400, 8440, 9056 Digital Communicators. When using the Scantronic 7200 or 7300 programmer, full NVM access is enabled. 44 = DigiCom D1100 & D1101 Digital Communicators. Scantronic Scancom units will NOT operate with this address being set to NVM Version - not used. This is reserved for use when a Scantronic digital communicator NVM is used. 24. DigiCom Version - two BCD digits, i.e. 00 to 99 will be written to this address to identify the version of the PSTN package of software that is in the microprocessor. This address is written to during power-up. 25. Long Telephone Numbers - there is space in the NVM for 4 standard-length telephone numbers or 3 long numbers. Long numbers may contain upto 28 digits each. Standard numbers may contain upto 21 digits each. 26. Fast Test - reduces the regular auto-test call timer and line monitor timer from hours to minutes. This allows rapid testing of these features. 27. Long Anti-Jam - when triggered, the DigiCom will wait for a period in the on-hook state and with the linedivert relay operated to allow any call that may have been in progress to clear down. This period is normally 2 seconds. When Long Anti-Jam is selected, then the period is 4 seconds. 14. Troubleshooting and Help The Programming Socket does not Read or Program an NVM. Check that the NVM type is 93C46. The D0354 parallel programming socket is only for use with the Windows 95, 98 or ME operating systems. It cannot be used with Windows NT, 2000, XP or later operating system. The D0355 USB programming socket can be used with Windows 98, ME, NT, 2000, XP or later operatingsystems. Check that the NVM is fitted in the programming socket correctly. Try using a new NVM. Check that the programming socket is correctly connected to the correct PC port. Check that the PC port is working using other software that is known to use that port successfully. Try using another port if available. Check that no other software is running on the PC that uses that same port. Where the D0354 parallel programming socket is used, unplug any printer and check that the PSU is connected to the programming socket and has been set correctly. Check that the settings requirements of Section 11 are correct. The DigiCom transmission is not received by the Alarm Receiving Centre? Check that the NVM is fitted and has been correctly programmed, i.e. correct telephone numbers etc. Check that the DigiCom has been installed in accordance with the Installation Instructions. Check that the System Area of the NVM is correct. Check that the telephone numbers and account numbers (chip number) in the NVM are correct for the ARC. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 17

18 14. Troubleshooting and Help (cont d) The DigiCom reports PSTN Line Faults when the line is working. Ensure that the PSTN line has been connected to the DigiCom as recommended in the DigiCom Installation Manual. Refer to the line monitor, Section 6 in this manual. Ensure that the settings are suitable for the PSTN line that is connected to the DigiCom. Switch off all line monitor functions and try again. Disconnect any other telephone equipment connected to the PSTN line, e.g. another telephone, fax, modem etc., and try again. Disconnect any other telephone equipment connected to the DigiCom A1 and B1 terminals, e.g. another telephone, fax, modem etc., and try again. Help Desk If you have installed the D1154 programmer in accordance with these instructions, checked all the above points but are still experiencing problems you can contact your DigiCom supplier. In the UK, DigiCom and D1154 programmer installation, programming, operation or other questions may be addressed to: The Dycon Technical Support Desk: Tel: technical@dyconsecurity.com The Dycon web site contains the latest copies of all manuals for all products. Please ensure that you are working from the latest version. You can also download associated information and software samplers. Sales, shipping and contact information is here too. A CD is available that contains all manuals for all Dycon products and the programming software for DigiCom. Contact Dycon for more information. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 18

19 D0355 NVM Programming Socket APPENDIX 1 The D0355 NVM programming socket connects to a USB port on the PC and is used to read and program NVM chips that can then be plugged into a DigiCom. To use this USB programming socket, requires that the D1154 programmer software that runs on the PC must be version v or later, also that the Windows version is Windows 98 or more recent. The programming socket includes 3 LEDs to indicate its operation. These are described in the table below. LED INDICATION MEANING ACTION A, B & C Red, Yellow & Green LEDs Power-up Self Test Wait 5 seconds all on for 2 seconds A, B & C Red, Yellow & Green LEDs Cannot contact Programmer Start the Programmer software all fast flashing (3 per second) software on the PC A Red LED fast flash Cannot contact Programmer Check cables (3 per second) software on the PC Restart the Programmer software A Red LED on for 3 seconds Corrupted message on USB port Check cables Restart the Programmer software B Yellow LED on Reading or Writing NVM or Wait a few seconds until the Updating the firmware in the process is completed Programming Socket C Green LED fast flash Programming Socket has no Start the Programmer software (3 per second) firmware installed C Green LED slow flash Power applied The Programming Socket is ready for (1 per second) Waiting for commands from PC use C Green LED on Power applied Waiting for commands from PC Programming Socket Firmware The Programming Socket is ready for use Whenever the D1154 programmer software detects the D0355 programming socket on the PC s USB port it will read the version number of the firmware in the D0355 programming socket microprocessor. If this requires updating then the D1154 Programmer software will send new firmware to the D0355 programming socket microprocessor. Manually Wiping the Programming Socket Firmware In the event that firmware updating fails (see above) a message will be given on the PC screen. Restart the D1154 programmer software on the PC. If the fault persists then it will be necessary to manually wipe the firmware in the D0355 programming socket. To manually wipe the programming socket firmware: 1. Unplug the USB lead from the D0355 programming socket. 2. Remove the 4 screws that hold the D0355 programming socket case. 3. Lift the programming socket board away from its case to allow access to the underside of the board. 4. Press and hold the push-button that is next to the USB connector. 5. With the push-button held down, reconnect the USB lead. 6. Continue to hold the push-button until the yellow LED starts to flash rapidly. 7. Release the push-button. 8. Unplug the USB lead from the D0355 programming socket. 9. Reassemble the case and replace the 4 screws. Reconnect the USB lead to the D0355 programming socket and restart the D1154 programmer software. The D0354 NVM Programming Socket The D0354 NVM programming socket connects to a parallel (or printer) LPT port on the computer and can only be used with Windows versions 95, 98, 98SE or ME. This item will not be available after April This programming socket has a connector that is a feed-through type which your printer can also connect to. Some printers, particularly Hewlett Packard printers, operate in a different way to the majority of printers available. If you find that printing or NVM programming is adversely affected when the D0354 and the printer are connected, only connect one or the other to the PC parallel LPT port. Switch units are available from general PC suppliers to make this selection easier. Connect the PSU to the programming socket s PSU at the rear of the programmer. Where the DC voltage from the power supply can be adjusted, ensure that the setting on the power supply is: - 6 volts DC - the plug connector tip = positive Programming NVMs without the power supply is possible on some PCs. In these cases you do not need to connect the PSU. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 19

20 APPENDIX 2 Program Launcher The Program Launcher may be used to start (launch) any of the Dycon product programmers (and other Dycon product software) that have been installed on a PC. In addition the program launcher can open any of the manuals for those products. This means that individual shortcuts to each of the Dycon product programmers are no longer required. About the launcher Manual for the launcher Program launch buttons Manual for the programmer Manual for the product The Program Launcher main window Fig X2-1 Installation 1. When installing any of the Dycon product programmers, the Program Launcher will also be installed automatically. See Operational Notes below. 2. During the installation process, a Windows shortcut to the Program Launcher will be added to the start menu. In addition, a shortcut to the Program Launcher will be placed on the Windows desktop. Fig X2-2 - The Launcher shortcut D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 20

21 APPENDIX 2 Operational Notes The Dycon product installation software will install the Dycon programmer in the PROGRAM FILES \ DYCON folder on the PC s hard disk. Do not rename files or folders within the PROGRAM FILES \ DYCON folder because this will stop some programmes operating. The name of each product folder that is in the PROGRAM FILES \ DYCON folder must start with the letter D. The name of the executable file within each product folder must start with the letter D, e.g. D2054.EXE. There must be only one executable file within each product folder that starts with the letter D. The manual or help file(s) that are in each program folder must be in the Adobe Acrobat PDF format. Operation 1. Start the Program Launcher by double-clicking on the Dycon launcher icon that is in the Start menu, Programs option. Alternatively, the program can be started using the shortcut called Dycon launcher that has been placed on the Windows desktop. See Fig X The Program Launcher main window will open and will automatically show a button for each of the Dycon programmes that are in the PROGRAM FILES \ DYCON folder that is on the PC s hard disk. See Fig X2-1. When installed, the top line of each button will have a name that is the same as the product folder name that is in the PROGRAM FILES \ DYCON folder. This may be changed. See Settings below. The bottom line of each button will have the version number of the product software that is in that folder. 3. To start (launch) any of the listed programmes, simply press the appropriate launch button. See Fig X To start Adobe Acrobat and open the Manual for any of the listed programmes, simply press the Programmer Manual button for that programmer. This button name may be changed and/or a different manual may be selected. See Settings below. Note: Adobe Acrobat must already be installed on your PC for any manuals to be displayed. A copy of Adobe Acrobat is available on the Dycon Products CD. 5. To start Adobe Acrobat and open the manual for the associated product, simply press the relevant Product Manual button. This button name may be changed and/or a different manual may be selected. See Settings below. 6. If required, adjust the setup options for the Program Launcher as described in Settings below. 7. To display this manual when the Program Launcher window is open, click on the? button at the bottom left corner of the main window. 8. To display information about the Program Launcher, double-click the Dycon logo. 9. To close the Program Launcher and return to Windows, do any one of the following standard Windows closure actions: 1. Double-click the Icon in the top left corner of the main window. 2. Click the Icon in the top left corner of the main window to get a drop-down menu, select Close. 3. Click the X box in the top right corner of the main window. 4. On the keyboard, press and hold the Alt key, then press the F4 key. Settings - Launch Button Naming When installed, the top line of each launch button will have a name that is the same as the product folder name that is in the PROGRAM FILES \ DYCON folder. The name on the button can be changed to any name that you prefer. D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 21

22 APPENDIX 2 To change the launch button name: 1. Right-click on the launch button. A small Modify button will appear. 2. Left-click on the small Modify button. The Button Setup window appears. See Fig X In the Rename: box, the current name of the button is shown. Do not change this. 4. In the To: box, delete the current name and type your preferred name. 5. Press the OK button. 6. To return the button name to that of the product folder that is in the PROGRAM FILES \ DYCON folder, press the Default button. 7. To cancel a change before the OK button has been pressed, press the Cancel button. Settings - Manual Button Naming Fig X2-3 When installed, the Manual buttons will have the default name Programmer Manual and Product Manual. The name on each button can be changed to any name that you prefer. Where a manual is absent from the product folder that is in the PROGRAM FILES \ DYCON folder then the button will just show a small dash -. To change a Manual button name: 1. Right-click on the Manual button. A small Modify button will appear. 2. Left-click on the small Modify button. The Button Setup window appears. See Fig X In the Rename: box, the current name of the button is shown. Do not change this. 4. In the To: box, delete the current name and type your preferred name. 5. Press the OK button. 6. To return the button name to the default, i.e. Manual, press the Default button. 7. To cancel a change before the OK button has been pressed, press the Cancel button. Fig X2-4 D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 22

23 APPENDIX 2 Settings - Select a different Manual When installed, the Programmer Manual and Product Manual buttons will select the supplied English language manuals that is in the product folder within the PROGRAM FILES \ DYCON folder. The English language manual name for each product is DxxxxUK.PDF. Where one or more manuals (in the Adobe Acrobat PDF format) has been added to the product folder within the PROGRAM FILES \ DYCON folder, e.g. manual(s) written in a different language, then any one of these may be selected to be opened by each Manual button. To select a different manual that the Manual button will open: 1. Right-click on the Manual button. A small Modify button will appear. 2. Left-click on the small Modify button. The Button Setup window appears. See Fig X Press the arrow to the right of the Manual box and select the preferred Adobe Acrobat PDF file. 4. Press the OK button. 5. Press the Cancel button to close the Button Setup window. Settings - Translate all Messages and Warnings In addition to the button renaming facility described above, all screen messages and warnings may be translated as required. To select all screen messages and warnings: 1. Right-click on the Dycon logo. A small Translate button will appear. 2. Left-click on the small Translate button. The Translate Strings window appears. See Fig X In the Rename: box, the English language word/message is shown. 4. In the To: box, delete the current word/message and type your preferred word/message. 5. Press the Next button. Repeat Steps 3, 4, 5 until all screen messages and warnings are translated. 6. To return the word/message to the English language default word/message, press the Default button. 7. Press the OK button to save all of the changes and close the Translate Strings window. 8. Press the Cancel button to close the Translate Strings window without saving any of the changes. Fig X2-5 D1154 Digicom NVM Programmer V Installation Manual D1154-V4-05-IN/10B/v1 Page 23

Installation and Operation Manual for the D1154 Programmer for DigiCom NVM

Installation and Operation Manual for the D1154 Programmer for DigiCom NVM Installation and Operation Manual for the D1154 Programmer for DigiCom NVM For D1154 Version 2.02 Dycon Ltd Cwm Cynon Business Park Mountain Ash CF45 4ER UK Tel: +44 (0)1443 471 060 Fax: +44 (0)1443 479

More information

Installation Manual. for the Duet Range: D2600 Duet2 D2650 Duet3

Installation Manual. for the Duet Range: D2600 Duet2 D2650 Duet3 Installation Manual for the Duet Range: D2600 Duet2 D2650 Duet3 Dycon Ltd Cwm Cynon Business Park Mountain Ash CF45 4ER UK Tel: +44 (0)1443 471 060 Fax: +44 (0)1443 479 374 www.dyconsecurity.eu sales.en@dyconsecurity.eu

More information

660/960 Installation Guide

660/960 Installation Guide 660/960 Installation Guide Compatible Equipment 660: Any Scantronic control panel. 960: All control panels with the Scantronic plug-on footprint pins. 496354 Issue 1 1 of 16 660/960 Introduction The 660/960

More information

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual FERGUSON BEAUREGARD RTU-5000 Configurator User Manual FERGUSON BEAUREGARD RTU-5000 Configurator User Manual The Ferguson Beauregard RTU-5000 Configurator program and manuals are Copyright 1997-2004 by

More information

HP Travel Phone User s Guide

HP Travel Phone User s Guide HP Travel Phone User s Guide Version 1.0 Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products

More information

Installation and Operation Manual for the D5000 Audio Verification Unit

Installation and Operation Manual for the D5000 Audio Verification Unit Installation and Operation Manual for the D5000 Audio Verification Unit Incorporating D5010 MICROPHONE UNIT D5020 CHANNEL EXPANDER D5030 EXPANDER Dycon Ltd Tel: +44 (0)1443 471 060 Fax: +44 (0)1443 479

More information

Galaxy ACCeSS Lite Downloader

Galaxy ACCeSS Lite Downloader Galaxy ACCeSS Lite Downloader Installation and Operating Instructions Honeywell Security Table of contents Introduction...3 Note for Galaxy 3 series panels V5.0x...3 Installation...4 Set-up...4 Running

More information

Connected to the FP World

Connected to the FP World Connected to the FP World User Manual 2 mailcredit User Manual About this manual Target group Topics mailcredit.exe [Next] The User Manual of mailcredit is primarily aimed at users of FP franking machines

More information

Enterprise Edge 2.0 Personal Call Manager User Guide

Enterprise Edge 2.0 Personal Call Manager User Guide Enterprise Edge 2.0 Personal Call Manager User Guide www.nortelnetworks.com 2000 Nortel Networks P0911958 Issue 01 Contents Enterprise Edge Personal Call Manager 9 Using a handsfree telephone with Enterprise

More information

Firmware, Database, & PC Application Update Installation Instructions

Firmware, Database, & PC Application Update Installation Instructions Firmware, Database, & PC Application Update Installation Instructions IMPORTANT Please read before you begin the installation. To avoid possible errors, it is recommended to install the updates as described

More information

SYSTEM REQUIREMENTS...3 HARDWARE INSTALLATION: PCI Internal ADSL Modem...4 DRIVER INSTALLATION FOR BOTH LAN AND WAN MODE Windows 98...

SYSTEM REQUIREMENTS...3 HARDWARE INSTALLATION: PCI Internal ADSL Modem...4 DRIVER INSTALLATION FOR BOTH LAN AND WAN MODE Windows 98... Contents SYSTEM REQUIREMENTS...3 HARDWARE INSTALLATION:...4 - USB External Modem...4 - PCI Internal ADSL Modem...4 DRIVER INSTALLATION FOR BOTH LAN AND WAN MODE...5 - Windows 98...5 - Windows Me...7 -

More information

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3 THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Digi-modems Issue 3 Contents Com300 & Com2400 Installation Manual Contents 1. Regulatory Requirements... 3 General...3 Approval... 3 REN Rating... 3 2.

More information

Digivu Quick Start Guide. Digivu User Instructions

Digivu Quick Start Guide. Digivu User Instructions Digivu Quick Start Guide Digivu User Instructions Page - 2 Digivu User Instructions Page - 3 Table of contents Quick Start Guide 2 Digivu Functions 6 Connecting to a Vehicle Unit 6 Digivu Internal Memory

More information

VoIPvoice Integration User Guide. VoIPvoice Skype Integration. User Guide. Last Updated 30 November Page 1 of 28

VoIPvoice Integration User Guide. VoIPvoice Skype Integration. User Guide. Last Updated 30 November Page 1 of 28 VoIPvoice Skype Integration User Guide Last Updated 30 November 2005 Page 1 of 28 Contents 1 Getting Started 3 Who are VoIPvoice? 3 What is Skype? 3 Glossary of Terms 3 Minimum System Requirements 4 2

More information

Installing LE History Record Reader program software.

Installing LE History Record Reader program software. INSTALLATION & OPERATING INSTRUCTIONS FOR THE LE HISTORY RECORD READER These Instructions will inform you on how to install software to use the RS-232/USB Isolator- Adapter and your LE History Record Reader

More information

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01 Aristel Networks Pty Ltd All Round Cabling Solutions NEOS3003-3G01 Operating Manual * NEOS 3003-3G01 Supports 3G/UMTS 800/850/900/1900/2100 MHz bands Telstra-Vodafone-Optus supported in all areas. * Model:

More information

Firmware, Database, & PC Application Update Installation Instructions

Firmware, Database, & PC Application Update Installation Instructions Firmware, Database, & PC Application Update Installation Instructions IMPORTANT Please read before you begin the installation. To avoid possible errors, it is recommended to install the updates as described

More information

Getting Started. Here's how to get started using your Zip 250 drive: 1. Unpack the Zip 250 drive and accessories.

Getting Started. Here's how to get started using your Zip 250 drive: 1. Unpack the Zip 250 drive and accessories. Getting Started IMPORTANT! Before installing or using your Zip 250 drive, read and follow the USB guidelines to ensure reliable performance of your USB devices. Here's how to get started using your Zip

More information

2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM

2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM 2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM CONTENTS PAGE Manual Introduction 3 Product Overview 3 Operation and Connection 3 RS232 Connection 3-4 RS485 Connection 3-4 2214 PCB layout 5 RS485 Bus Terminal

More information

Hi-Phone DeskTop USB H/W User Manual

Hi-Phone DeskTop USB H/W User Manual Hi-Phone DeskTop USB H/W User Manual 1.08.08 Way2call Communication Ltd. reserves the right to make changes to the Hi-Phone devices and to the content of this document without notice 2001 Way2call Communications

More information

CellRoute 3G. Fixed Wireless Terminal. Data Connectivity

CellRoute 3G. Fixed Wireless Terminal. Data Connectivity CellRoute 3G Fixed Wireless Terminal Data Connectivity Version 2 December 2010 This manual will help you to set-up the CellRoute 3G on your PC or laptop. Follow the instructions that apply to the version

More information

DT6I Series 2 INTERROGATABLE 6 CHANNEL TALKING DIALLER. INSTALLATION MANUAL 2 nd EDITION.

DT6I Series 2 INTERROGATABLE 6 CHANNEL TALKING DIALLER. INSTALLATION MANUAL 2 nd EDITION. INTERROGATABLE 6 CHANNEL TALKING DIALLER 2 nd EDITION. NEW FEATURES Simplified memory layout allowing for quicker and easier programming. Can now record individual messages for each of the 5 external alarm

More information

ID-Manager. PC program for Windows 98 and later versions of Windows. User manual for ID Manager

ID-Manager. PC program for Windows 98 and later versions of Windows. User manual for ID Manager ID-Manager PC program for Windows 98 and later versions of Windows User manual for ID Manager Contents 1 INSTALLATION...3 1.1 MANAGER INSTALLATION...3 1.2 INSTALLATION OF USB DRIVER...3 2 ID MANAGER PROGRAM

More information

C-Bus Telephone Interface Training Manual V T Series

C-Bus Telephone Interface Training Manual V T Series V1.2 5100T Series Table of Contents 1.0 INTRODUCTION...4 2.0 DESCRIPTION...4 2.1 The CBTI unit comes with the following:...4 3.0 ABBREVIATIONS...5 4.0 CONTEXT DIAGRAM...5 4.1 Power supply...6 4.2 C-Bus

More information

A Division of Cisco Systems, Inc. PrintServer for USB. with 4-Port Switch. User Guide WIRED PSUS4. Model No.

A Division of Cisco Systems, Inc. PrintServer for USB. with 4-Port Switch. User Guide WIRED PSUS4. Model No. A Division of Cisco Systems, Inc. WIRED PrintServer for USB with 4-Port Switch User Guide Model No. PSUS4 Copyright and Trademarks Specifications are subject to change without notice. Linksys is a registered

More information

EU Driver s Hours Rules covered by Digifobpro. Table of contents

EU Driver s Hours Rules covered by Digifobpro. Table of contents EU Driver s Hours Rules covered by Digifobpro Digifobpro provides analysis of Driver Cards both in it s Quick View and Driver Card - Download features ( see Digifobpro Functions page 4). There follows

More information

Ishida Label Editor USER GUIDE

Ishida Label Editor USER GUIDE Ishida Label Editor USER GUIDE ISHIDA CO., LTD Copyright 2000 Ishida Co. Ltd., Japan Copyright 2000 Interface Translation Ltd., New Zealand No part of this manual may be reproduced or transmitted in any

More information

NEO & TRINITY Troubleshooting

NEO & TRINITY Troubleshooting NEO & TRINITY Troubleshooting Version Control Version Number Date Changed by 1 2nd February 2017 Nicola Latter 2 6 th February 2017 Kevin Wilson 3 7 th February 2017 Nicola Latter 4 15 th February 2017

More information

PCS 60 User Manual. Version 3.2. April 2009 Part No. DOC-MN-PCS60-00

PCS 60 User Manual. Version 3.2. April 2009 Part No. DOC-MN-PCS60-00 Version 3.2 April 2009 Part No. DOC-MN-PCS60-00 Document No. 005 Version No. V3.2/0409/4 Copyright SpliceCom Ltd SpliceCom Ltd The Hall Business Centre, Berry Lane Chorleywood, Herts WD3 5EX Tel: 01923

More information

IP Office Voic Pro

IP Office Voic Pro IP Office Voicemail Pro 40DHB0002USAW Issue 4 (11/26/2001) Contents Voicemail Pro... 4 Overview... 4 Voicemail Lite Features... 4 Voicemail Pro Components... 5 Installing Voicemail Pro... 6 Pre-Installation

More information

Infrared Docking Station

Infrared Docking Station For uploading voice files to Enterprise Express Infrared Docking Station Operating Instructions Contents Overview...1 What s In The Box...1 System Requirements...1 Where to Go From Here...3 Getting Help...4

More information

LASER PRINTER. Software Setup Guide BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING

LASER PRINTER. Software Setup Guide BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING MODEL: MX-B400P LASER PRINTER Software Setup Guide BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING Keep this manual close at hand for reference

More information

Contents. 1. Introduction Installation Serial Port Option USB Driver Installation Testing USB Device Detection...

Contents. 1. Introduction Installation Serial Port Option USB Driver Installation Testing USB Device Detection... Contents 1. Introduction...4 2. Minimum System Requirements 4 3. Specifications.4 4. Installation...4 4.1 Serial Port Option..4 4.2 USB Driver Installation.. 5 5. Testing USB Device Detection...8 6. Configuring

More information

FIREPOWER M04 RGB MMO LASER MOUSE INSTRUCTION MANUAL ADXLM0418

FIREPOWER M04 RGB MMO LASER MOUSE INSTRUCTION MANUAL ADXLM0418 FIREPOWER M04 RGB MMO LASER MOUSE INSTRUCTION MANUAL ADXLM0418 Contents Safety Warnings... 4 Unpacking... 5 Product Overview... 6 Adjusting the Weight... 7 System Requirements... 8 Software Installation...

More information

Tait Orca Download and Configuration Application

Tait Orca Download and Configuration Application Tait Orca Download and Configuration Application User s Manual December 2001 439-53010-03 Contents Getting Started...5 Minimum System Requirements...5 Equipment Supplied...5 Application Installation...5

More information

TopGuard Online Help PATROL AND PATROL PLUS

TopGuard Online Help PATROL AND PATROL PLUS TopGuard Online Help PATROL AND PATROL PLUS Copyright Guard Control Systems 2009. All rights reserved. Microsoft and Windows are registered trademarks of Microsoft Corporation. All other trademarks and

More information

The Flexischools Online Order Management System Installation Guide

The Flexischools Online Order Management System Installation Guide The Flexischools Online Order Management System Installation Guide Page 1 of 18 Installation Pack Welcome to the Flexischools system. You will have received a disc containing: Sato Drivers Flexischools

More information

Windows Me Navigating

Windows Me Navigating LAB PROCEDURE 11 Windows Me Navigating OBJECTIVES 1. Explore the Start menu. 2. Start an application. 3. Multi-task between applications. 4. Moving folders and files around. 5. Use Control Panel settings.

More information

Quick Start. Chapter. In This Chapter:

Quick Start. Chapter. In This Chapter: Chapter Quick Start In This Chapter: Getting to Know Windows.... - Installation of irectsoft 6.... - Getting Started.... -8 Welcome to irectsoft00.... - Begin Editing a Program.... -4 Establish the Communication

More information

USB-Link Technical Guide

USB-Link Technical Guide www.wattmaster.com USB-Link Technical Guide USB-Link Code: SS0070 Table of Contents General Information... 3 USB-Link Overview...3 System Requirements...3 Quick Guide... 4 Connection and Wiring... 5 USB-Link

More information

VSM Manager. The VSM Manager is a Windows GUI that can be installed to serially control Genesis Matrixes with a firmware of version 2.5 or later.

VSM Manager. The VSM Manager is a Windows GUI that can be installed to serially control Genesis Matrixes with a firmware of version 2.5 or later. VSM Manager Table of Contents Overview...1 Getting Started...1 Toolbar... 2 Serial Connection... 2 Refresh... 3 Help... 3 Tab Pages... 4 General... 4 Control...5 Schedule... 6 Command... 6 Communications...

More information

PhoneLink for Outlook User Manual

PhoneLink for Outlook User Manual PhoneLink for Outlook User Manual for use with 8810, 8610/8620, and 6210/6220 ISDN Telephones PhoneLink for Outlook is an add-in for Microsoft Outlook that manages inbound calls to multiple call appearances

More information

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup) INPUTS: All inputs: Inputs 1 to 24: Tamper: Panic: Fire: Keyswitch: 16-18VAC: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

More information

SS-10 3G USER MANUAL FIXED CELLULAR TERMINAL. DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20

SS-10 3G USER MANUAL FIXED CELLULAR TERMINAL. DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20 SS-10 3G FIXED CELLULAR TERMINAL USER MANUAL DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20 Revision History: Revision 01 Original document 12 August 2010 CONTENTS 1 INTRODUCTION...3 2 FEATURES...4 2.1 PHYSICAL

More information

GPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher

GPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher GPRS ADAPTER INSTALLATION AND USER MANUAL for module version v2.24 and higher Table of contents 1 Main function of the Adapter...3 2 System operation...3 2.1 Transmission through GPRS...4 2.1.1 Router

More information

This is Your Software Security Access Key: DO NOT LOSE IT!

This is Your Software Security Access Key: DO NOT LOSE IT! This is Your Software Security Access Key: DO NOT LOSE IT! DO NOT PLUG THE SECURITY KEY INTO ANY ELEVATOR INTERFACE PORT This security device must be plugged into the notebook computer s PRINTER port whenever

More information

Software Setup Instructions for the Foster Control System used in the Explora Dome Observatories

Software Setup Instructions for the Foster Control System used in the Explora Dome Observatories Software Setup Instructions for the Foster Control System used in the Explora Dome Observatories Contents Pages 3 & 4 The new tic counter system & home position sensor Page 5 Control Boxes Pages 6-8 Down

More information

MAINTEX. User Guide INS571

MAINTEX. User Guide INS571 TM MAINTEX User Guide INS571 Contents Contents... 2 Introduction... 3 Installation... 3 Starting Maintex... 3 User Logon... 4 How to create a new Operator... 5 Connection Setup... 7 Modem Setup... 8 Network

More information

Networking the printer

Networking the printer Networking the printer General networking Networking overview A network is a collection of devices such as computers, printers, Ethernet hubs, wireless access points, and routers connected together for

More information

User s guide for Windows 98 and Me

User s guide for Windows 98 and Me User s guide for Windows 98 and Me The information in this manual may be modified without prior notice. THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THERE IS A PARTIAL DISCREPANCY BETWEEN THE MANUAL

More information

INSTALLATION AND USER GUIDE

INSTALLATION AND USER GUIDE INSTALLATION AND USER GUIDE Introduction 1 Introduction About 6140 Agent Portal Mitel Networks 6140 Agent Portal allows an agent to receive call information via a number of different applications that

More information

NEOS3000A GSM Least Cost Wireless Router

NEOS3000A GSM Least Cost Wireless Router NEOS3000A GSM Least Cost Wireless Router Operating Manual. NEOS3000A Operating manual Ver. 1.1 March 2004 page 1 Introduction Thank you for purchasing the NEOS3000A product from Aristel Networks Australia.

More information

SCD Live SPEED TECH A/S

SCD Live SPEED TECH A/S SPEED TECH A/S Nybrovej 97. DK2820 Gentofte. Phone: +45 45938545 Fax: +45 45938544 www.doorcontrol.dk - info@speed-tech.dk Contents: SCD Live 1 INTRODUCTION... 3 1.1 DESCRIPTION... 3 1.2 DISCLAIMER...

More information

Operating Instructions

Operating Instructions Operating Instructions For Digital Camera PC Connection QuickTime and the QuickTime logo are trademarks or registered trademarks of Apple Computer, Inc., used under license. Connection with the PC Offers

More information

Remote Tools User Guide

Remote Tools User Guide Remote Tools User Guide Copyright Northern Telecom 1999 Norstar is a trademark of Northern Telecom. Microsoft, MS-DOS, Windows and Excel are registered trademarks and Windows is a trademark of Microsoft

More information

DBT-120 Bluetooth USB Adapter

DBT-120 Bluetooth USB Adapter DBT-120 Bluetooth USB Adapter Rev.2.1 (09/25/2002) 2 Contents Introduction... 5 Package Contents... 6 Installing Bluetooth Software... 6 Hardware Installation... 8 Introduction to Bluetooth Software...

More information

CCTV42 System2 DVR Quick Start Guide 4/8/16-Ch DVR

CCTV42 System2 DVR Quick Start Guide 4/8/16-Ch DVR CCTV42 System2 DVR Quick Start Guide 4/8/16-Ch DVR If you have purchased a DVR / Hard drive package from us then we will have already installed the hard drive(s) and configured the basic settings on your

More information

DigidownHost. Software User s Guide. Lisle Design Ltd 2014 Subject to change without notice

DigidownHost. Software User s Guide. Lisle Design Ltd 2014 Subject to change without notice DigidownHost Software User s Guide Subject to change without notice DigidownHost User s Guide Contents About DigidownHost... 2 Installing DigidownHost... 3 The DigidownBase Driver Installer... 9 Uninstalling

More information

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0 MCM Electronics MCM Electronics MCM Electronics The Icon Series Installation and Programming Information Icon 8 Version 5.0 TABLE OF CONTENTS 1. 2. 3. Panel Hardware Page 2 Physical Layout. Inputs. Outputs.

More information

NEOS3000A GSM Least Cost Wireless Router

NEOS3000A GSM Least Cost Wireless Router NEOS3000A GSM Least Cost Wireless Router For model GW-NEOS-TC35A5-Q1 or later Operating Manual. Model GW-NEOS-TC35A5-Q1 or later Operating manual Ver. 1.2 November 2005 page 1 Introduction Thank you for

More information

Wireless-G. User Guide. PrintServer for USB 2.0. GHz g WPS54GU2. A Division of Cisco Systems, Inc. WIRELESS. Model No.

Wireless-G. User Guide. PrintServer for USB 2.0. GHz g WPS54GU2. A Division of Cisco Systems, Inc. WIRELESS. Model No. A Division of Cisco Systems, Inc. GHz 2.4 802.11g WIRELESS Wireless-G PrintServer for USB 2.0 User Guide Model No. WPS54GU2 Copyright and Trademarks Specifications are subject to change without notice.

More information

Peerless Drive System User's Manual

Peerless Drive System User's Manual Peerless Drive System User's Manual Copyright 2001 Iomega Corporation Iomega, the stylized "i" logo, Peerless, and the Peerless brand block are either registered trademarks or trademarks of Iomega Corporation

More information

BCM 4.0 Personal Call Manager User Guide. BCM 4.0 Business Communications Manager

BCM 4.0 Personal Call Manager User Guide. BCM 4.0 Business Communications Manager BCM 4.0 Personal Call Manager User Guide BCM 4.0 Business Communications Manager Document Status: Beta Document Version: 02 Part Code: N0027256 Date: January 2006 Copyright Nortel Networks Limited 2006

More information

Setup for LAUSDnet - Windows 95/98/ME Revised 8/1/2001

Setup for LAUSDnet - Windows 95/98/ME Revised 8/1/2001 Setup for LAUSDnet - Windows 95/98/ME Revised 8/1/2001 Dial Up Networking Setup The following assumes that the Dial-Up Networking portions of Windows 95/98/ME have already been installed. If they have

More information

Programming Manual KX-TVA50 KX-TVA200. Voice Processing System. Model No.

Programming Manual KX-TVA50 KX-TVA200. Voice Processing System. Model No. Programming Manual Voice Processing System KX-TVA50 KX-TVA200 Model No. Thank you for purchasing a Panasonic Voice Processing System. Please read this manual carefully before using this product and save

More information

MF9300. Software setup guide

MF9300. Software setup guide MF900 Software setup guide 0000 79-0 S INTRODUCTION This manual explains how to install and configure the software that is required for the printer function of the machine. The procedure for viewing the

More information

ATL20 ATL30 Automatic transfer switch controller

ATL20 ATL30 Automatic transfer switch controller I 194 GB 07 07 ATL20 ATL30 Automatic transfer switch controller REMOTE CONTROL SOFTWARE MANUAL Summary Introduction... 2 Minimum resources of the PC... 2 Installation... 2 Activation of the PC-ATL connection...

More information

Device Programming using TRWinProg

Device Programming using TRWinProg Device Programming using TRWinProg Software No.: _490-00416 _490-00416_WIN7 _Program Summary _Safety instructions _System requirements _Program installation _Connecting devices to the PC _Program start

More information

Astribank 8, 16, 24 and 32 Getting Started

Astribank 8, 16, 24 and 32 Getting Started Astribank 8, 16, 24 and 32 Getting Started Contents Next Page Astribank Getting Started Document Information This document YD3430-02 is current with Astribank-8, Astribank-16, Astribank-24, and Astribank-32

More information

Installation Manual for D244X Series 24-volt Power Supplies

Installation Manual for D244X Series 24-volt Power Supplies Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power

More information

Norstar PC Console 1.1 User Guide

Norstar PC Console 1.1 User Guide Norstar PC Console 1.1 User Guide Norstar is a trademark of Northern Telecom Copyright Northern Telecom 1998 1-800-4 NORTEL www.nortel.com/norstar Norstar is a trademark of Northern Telecom Printed in

More information

Projector Operation Guide

Projector Operation Guide Projector Operation Guide Contents 2 Introduction Making effective use of your projector... 6 Sending Images Via a Network (EMP NS Connection) (EB-826W/825/85).......... 6 Monitor, configure, and control

More information

GSC300 CONFIGURATOR SOFTWARE INTERFACE. Installation and User Manual for the GSC300 Configurator PC Software Interface

GSC300 CONFIGURATOR SOFTWARE INTERFACE. Installation and User Manual for the GSC300 Configurator PC Software Interface GSC300 CONFIGURATOR SOFTWARE INTERFACE Installation and User Manual for the GSC300 Configurator PC Software Interface File: ConfiguratorRev1.5.2.doc Feb.21, 2006 2 READ MANUAL BEFORE INSTALLING UNIT END-USER

More information

GPRS-T1. Monitoring Converter. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

GPRS-T1. Monitoring Converter. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel Monitoring Converter GPRS-T1 Program version 1.01 gprs-t1_en 04/09 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl WARNINGS The module should only

More information

EasyMP Operation Guide. Multimedia Projector. PowerLite 826W PowerLite 825 PowerLite 85

EasyMP Operation Guide. Multimedia Projector. PowerLite 826W PowerLite 825 PowerLite 85 EasyMP Operation Guide Multimedia Projector PowerLite 826W PowerLite 825 PowerLite 85 Contents 2 Introduction Making effective use of your projector......................... 6 Sending Images Via a Network

More information

Hi-Phone DeskTop H/W User Manual

Hi-Phone DeskTop H/W User Manual Hi-Phone DeskTop H/W User Manual 1.07.98 Way2call Communication Ltd. reserves the right to make changes to the Hi-Phone devices and to the content of this document without notice 2001 Way2call Communications

More information

Computer Basics. Hardware. This class is designed to cover the following basics:

Computer Basics. Hardware. This class is designed to cover the following basics: Computer Basics This class is designed to cover the following basics: computer hardware software computer s operating system different kinds of storage devices you can use to save files using a mouse what

More information

Introduction to the Autologic Vehicle Diagnostic Tool

Introduction to the Autologic Vehicle Diagnostic Tool Introduction to the Autologic Vehicle Diagnostic Tool User Instructions Version 4.0 Issued April 2012 For the latest version of this document see www.autologic.com Ltd has made every effort to make sure

More information

Alphacom a200 USER GUIDE. Versatility 1 & Value

Alphacom a200 USER GUIDE. Versatility 1 & Value Alphacom a200 a RANGE telephone USER GUIDE Versatility 1 & Value CONTENTS Page 1. GUARANTEE 2 2. CONDITIONS OF USE 2 3. facilities and features 3 4. LOCATIONS OF CONTROLS 4 5. UTILISATION OF CONTROLS 5

More information

Impact-C computer user manual Part No: issue A2

Impact-C computer user manual Part No: issue A2 Impact-C computer user manual Part No: 85080318 issue A2 Thank you for purchasing an Impact-C tower PC system. This manual will help you get started using your Impact-C and provide you with information

More information

Using LaunchPad. Contents. Section 1-7. This section: Describes how to use LaunchPad to run your access control programs.

Using LaunchPad. Contents. Section 1-7. This section: Describes how to use LaunchPad to run your access control programs. Section 1-7 Using LaunchPad This section: Describes how to use LaunchPad to run your access control programs. Describes how to change your login name and password Describes how to add new operators. Describes

More information

Operating Instructions

Operating Instructions Operating Instructions (For User Setup) Digital Colour Imaging Systems Model No. DP-C406 / C306 / C266 Table of Contents Installation Overview General Installation Overview...2 Installation Installing

More information

CellSync Manager. User Manual F8V7D006-SS F8V7D008-SS. Get online and synchronize anywhere. Web Access. Phone Book Manager

CellSync Manager. User Manual F8V7D006-SS F8V7D008-SS. Get online and synchronize anywhere. Web Access. Phone Book Manager CellSync Manager Get online and synchronize anywhere Web Access Phone Book Manager User Manual F8V7D006-SS F8V7D008-SS TABLE OF CONTENTS Introduction...2 Interactive Phone Menu...3 LG 5350 CellSync Software

More information

T-30 Skype USB Phone Gateway User Manual

T-30 Skype USB Phone Gateway User Manual T-30 Skype USB Phone Gateway User Manual 1. Skype Driver Installation Note: Cancel this procedure if you have already installed Skype software 1.1 Install Skype Put the CD from package into CD-ROM; click

More information

Bluetooth PC Card from IBM

Bluetooth PC Card from IBM Bluetooth PC Card from IBM Installation and User s Guide IBM 19K4260 Note: Before using this information and the product it supports, read Appendix E, Product warranties and notices on page E-1. First

More information

Operating Instructions

Operating Instructions Operating Instructions For Digital Camera PC Connection QuickTime and the QuickTime logo are trademarks or registered trademarks of Apple Inc., used under license therefrom. VQT1H07 Connection with the

More information

Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter

Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter Updates to the Field Guide and to the instrument firmware are available from the Applied Instruments website.

More information

& Technical Specifications

& Technical Specifications User Manual & Technical Specifications User manual Contents Pidion BM-170 Technical specifications... 2 Micro Rolltalk basic package... 3 Micro Rolltalk functions and buttons... 3 Preparing Micro Rolltalk...

More information

Business Communications Manager 3.0 Attendant Console Set Up and Operation Guide

Business Communications Manager 3.0 Attendant Console Set Up and Operation Guide Part No. P0936570 04 Business Communications Manager 3.0 Attendant Console Set Up and Operation Guide 2 Copyright 2002 Nortel Networks All rights reserved. The information in this document is subject to

More information

Berkshire 600 AG. User Guide

Berkshire 600 AG. User Guide Berkshire 600 AG Thank you for choosing a Berkshire 600 AG telephone. You have selected a carefully designed telephone that incorporates the very latest technology, offering a stylish instrument, and providing

More information

How to resolve PINPad offline issues

How to resolve PINPad offline issues How to resolve PINPad offline issues Most PINPad offline issues are due to one or more of the following 1) The PC-EFTPOS software is on an older release, or 2) The latest USB drivers for the PINPad have

More information

IMO. ismart. Training Manual

IMO. ismart. Training Manual IMO ismart Training Manual automation@imopc.com IMO IMO Precision Controls 1000 North Circular Rd Staples Corner London NW2 7JP Tel: +44 (0) 208 452 6444 Fax: +44 (0) 208 450 2274 Email: sales@imopc.com

More information

This manual covers 3Com U.S. Robotics faxmodems.

This manual covers 3Com U.S. Robotics faxmodems. This manual covers 3Com U.S. Robotics faxmodems. 3Com, the 3Com logo, U.S. Robotics, and Winmodem are registered trademarks and Connections, RapidComm, and x2 are trademarks of 3Com Corporation. Windows

More information

Ardac Elite EP Host Manual TSP020.doc Issue 4.2 May 2008

Ardac Elite EP Host Manual TSP020.doc Issue 4.2 May 2008 Ardac Elite EP Host Manual TSP020.doc Issue 4.2 May 2008 User Guide Page 1 of 37 Ardac Elite EP User Guide Contents 1 Introduction... 3 2 Getting started... 4 2.1Equipment supplied...4 2.2To power up the

More information

SUPERSCAN II. Always a step ahead.

SUPERSCAN II. Always a step ahead. SUPERSCAN II Always a step ahead. Operations Manual DEC Automotive Pedro Lozano 4453 Capital Federal C 1417 EEY Argentina Telephone +54 11 4567 1188 / 3994 Fax +54 11 4639 8643 http://www.decautomotive.net/

More information

SkyeLynxComms DataHog Communications Software

SkyeLynxComms DataHog Communications Software DataHog Communications Software SKLS 990 Skye Instruments Ltd., 21 Ddole Enterprise Park, Llandrindod Wells, Powys LD1 6DF UK Tel: +44 (0) 1597 824811 skyemail@skyeinstruments.com www.skyeinstruments.com

More information

Programming Manual KX-TVA50 KX-TVA200. Voice Processing System. Model

Programming Manual KX-TVA50 KX-TVA200. Voice Processing System. Model Voice Processing System Programming Manual Model KX-TVA50 KX-TVA200 Thank you for purchasing a Panasonic Voice Processing System. Please read this manual carefully before using this product and save this

More information

Start Here. Important setup information. Remove all tape and lift display. Locate components

Start Here. Important setup information. Remove all tape and lift display. Locate components Start Here 1 Important setup information Wireless or wired network users: you must follow the instructions in this setup guide to be successful adding the HP All-in-One to your network. USB cable users:

More information

ipassconnect 2.4 Client User Guide

ipassconnect 2.4 Client User Guide ipassconnect 2.4 Client User Guide ipassconnect 2.4 Client User Guide For Microsoft Windows Operating Systems ipass Inc. Table of Contents Introduction... 4 Key Features...4 Dialing Intelligence...4 Automatic

More information

SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM

SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM CONTENTS ABOUT THE SOFTWARE BEFORE INSTALLATION INSTALLING THE SOFTWARE CONNECTING TO A COMPUTER CONFIGURING THE PRINTER DRIVER TROUBLESHOOTING Page

More information