OIW-EX 1000 Oil in Water Monitors
|
|
- Edwina Haynes
- 6 years ago
- Views:
Transcription
1 OIW-EX 1000 Oil in Water Monitors Spectrometer Handbook Document code: OIW-HBO-0005 Version: EX Tel: +44(0) FAX +44(0) Page 1 of 33
2 Document History 1. Version A Draft...First draft separated from installation and User Handbook 1st May Version B Draft...Updated to reflect change to support the v2 Spectrometer 3 rd April Version C...Preface page updated 12 th June Version 1...First Release after Review 29 th June Version 2...Updated in-line with Version 4 of the OIW software 19 th Jan Tel: +44(0) FAX +44(0) Page 2 of 33
3 Preface This handbook is part of a library of handbooks that cover the full operation of the OIW-EX Series of products. The table below indicates the handbooks available. Please ensure that you have read all handbooks required for your job function. Note: please ensure you have the latest version of these documents password protected copies of the documents together with a table of the latest revisions are available on-line at: The passwords may be obtained directly from Advanced Sensors Ltd. Handbooks Descriptions Code Handbook Description OIW EX Model OIW-HBO 0001 Installation Hardware related details required for the physical installation of the OIW-EX Series of units User An overview of the operation of the OIW-EX Series of products and details how to configure the unit Data Logging Information on how to access and examine the data log and system log files Remote How to control the OIW-EX Series of units remotely. Access 0005 Spectrometer Operation of the spectrometer and associated Spectrometer files Wireless Set up and use of the handheld wireless controller. O O O O Controller 0007 Flush Valve Operation of the OIW-EX Series of units when a Flush Valve is fitted. O O O 0008 Dual Flow Operation of the OIW-EX Series of units when used in a Dual Flow Mode. O O O 0009 Microscopy Operation of the OIW-EX Series of units with Microscopy files Hart Operation of the OIW-EX Series of units with 0011 In-Line Probe User 0012 In-Line Probe Installation supporting Hart. O O O O Operation of the OIW-EX Series of units with an In-Line Probe. Installation of the OIW-EX Series of units with an In-Line Probe P 4000 Key = Required O = Optional Tel: +44(0) FAX +44(0) Page 3 of 33
4 Table of Contents 1 OIW-EX Spectrometer Handbook Introduction Modes of Operation Health & Safety Spectrometer Overview Identifying an OIW EX1000 Unit Showing and Hiding the Spectrum Spectrum Reading Cycle Spectra Control Options Spectrometer Standard Creation Spectrum Reading Cycle Explained Measuring Cycles Spectrum Operation PPM Level Triggered Spectrum Operation Manual Spectrum Operation Spectrum Control Options Spectrum Smoothing Spectrum Averaging Spectrum Integration Time Spectrum Control Options Water Status off/on Changing % Mask Tolerance Changing the Lower Wavelength Changing the Upper Wavelength Changing the Upper Wavelength Changing the % Above Line Spectrum Log Files Using SpAn Starting SpAn Loading a spectrum log File Auto Scaling Identifying Points on the Graph Saving/Loading Spectral Data File Sets Printing Errors with EX Appendix 1 OIW-EX Series Contact Details Tel: +44(0) FAX +44(0) Page 4 of 33
5 Symbols in this document The following symbols are used in this document to indicate special information: Warning an instruction that draws attention to the risk of injury or death. Caution an instruction that draws attention to the risk of damage to the product, process or surroundings. Note Clarification of an instruction or additional information. Information Further reference for more detailed information or technical details. NOTE: although Warning hazards are related to potential personal injury, and Caution hazards are associated with material damage, it must be understood that operation of damaged equipment could lead to personal injury or death. All Warning and Caution hazards must be complied with. Tel: +44(0) FAX +44(0) Page 5 of 33
6 1 OIW-EX Series with Spectrometer fitted - Spectrometer Handbook 1.1 Introduction This spectrometer handbook provides user information on how to use and configure the Advanced Sensors Ltd OIW-EX Series Oil in Water Monitor Systems spectrometer features only for all other features please refer to the User Handbook. This manual relates to the functionality of the OIW-EX Series unit at software release v4 and above. CAUTION: This manual describes the operation and use of the spectrometer features only NOT the installation. Ensure that the unit has been correctly installed in line with the Installation Handbook prior to use. 1.2 Modes of Operation The OIW-EX Series have been designed with maximum flexibility in mind enabling them to be configured in a verity of ways to suit different customer requirements. CAUTION: Should the equipment be used in a manner not specified in this handbook the sensor may not function correctly and protection provided by the equipment may be impaired. CAUTION: No options should be altered without a full understanding of the change being made. 1.3 Health & Safety WARNING: This document relates to electrical equipment of substantial weight. Health and Safety section of the Installation Handbook must be read carefully and understood before using this equipment. NOTE: although Warning hazards are related to personal injury, and Caution hazards are associated with material damage, it must be understood that operation of damaged equipment could lead to personal injury or death. Therefore all Warning and Caution hazards must be complied with. Tel: +44(0) FAX +44(0) Page 6 of 33
7 2 Spectrometer Overview The OIW-EX Series fitted with a Spectrometer enhances the functionality of the standard unit by incorporating an optical spectrum analyser unit which allows for enhanced analyses of the produced water in the sample chamber. The following OIW-EX Series models all have Spectrometer fitted as standard: OIW-EX1000, OIW-EX1000P and OIW-EX4000. Advanced Sensors software suite includes SpAn. The SpAn software tool simplifies the analysis of multiple optical scans. As with all data logs generated by the OIW-EX Series of products the spectrum analyser files are created in generates industry standard.csv file format allowing the user the flexibility to analyse the data in a tool of their choosing. The following sections will detail the operation of the spectrum analyser unit and will provide details on how to use the SpAn software details will also be provided on the file format should the use wish to analyse the data with alternative tools. Tel: +44(0) FAX +44(0) Page 7 of 33
8 2.1 Identifying an OIW EX Series Unit with a Spectrometer The OIW-EX 100 software, see Figure 2, can be distinguished from the OIW-EX Series with Spectrometer fitted, see Figure 1, primarily by the software header box, which clearly identifies unit type in its header, shown below. The following OIW-EX Series models all have Spectrometer fitted as standard 1 : OIW-EX1000, OIW-EX1000P and OIW-EX4000. Figure 1. OIW-EX100 software Figure 2. OIW-EX1000 software The following sections will detail the operation of the spectrum analyser unit and will provide details on how to use the SpAn software details will also be provided on the file format should the use wish to analyse the data with alternative tools. 1 Though out the rest of this Handbook the term OIW-EX1000 is used; but this also covers all OIW-EX Series with a Spectrometer fitted; i.e. OIW-EX1000, OIW-EX1000P and OIW-EX Tel: +44(0) FAX +44(0) Page 8 of 33
9 2.2 Showing and Hiding the Spectrum The graph panel of the OIW-EX 1000 software will allow you to switch between showing the oil ppm level, the spectrum of the oil or both, see Figure 3. Figure 3. View of OIW EX1000 PPM/PPB and Spectrum Clicking the Spectra button, see Figure 3, when the oil ppm level is displayed, will display the Spectra screen on view, see Figure 3. Clicking the Hide button, see Figure 3, when Spectra view is displayed will display the oil ppm level, see Figure 3. Clicking the button, see Figure 3, when Spectra view is displayed will display the oil ppm level and the Spectra, see Figure 3. Clicking the button, see Figure 3, when the oil ppm level and Spectra are displayed will display just the oil ppm level, see Figure 3. Tel: +44(0) FAX +44(0) Page 9 of 33
10 2.3 Spectrum Reading Cycle As with the oil detection system the spectrum analyser requires the laser light as an illumination source therefore the analyser will not operate when the measurement cycle is in the stopped position. The spectrum analyser can take a reading based on any one of three conditions: The OIW System software periodically requests a reading based on a user selectable time period; The PPM level rises above the User Set trigger level; The user manually requests a reading. Each of these trigger conditions will be discussed in more detail below but the reading cycle remains the same for each condition. The user can have any combination of trigger conditions including all conditions at the same time i.e. the system can be set to trigger a reading every hour and trigger a reading if 100ppm is exceeded and select a manual reading. Note: only one reading will be taken at a time. Tel: +44(0) FAX +44(0) Page 10 of 33
11 2.4 Spectra Control Options The spectrum analyser controls can be accessed via the Oil Calibration Settings and Configuration Options tabs once you have logged in to the configuration menu, see Figure 4. Figure 4. Spectrometer Controls NOTE: if the spectrometer was not detected or if communications between the main OIW system and the spectrum analyser are lost the Take Spectra button is replaced with the word Fault. Tel: +44(0) FAX +44(0) Page 11 of 33
12 2.4.1 Spectrometer Standard Creation Under the Oil Calibration Settings tab is an option to create a Spectrometer standard. Future Spectrometer reading may be compared with this standard and an alarm may be raised if the composition of the oil changes significantly. Figure 5. Scheduled Auto Settings As with the oil detection system the spectrum analyser requires the laser light as an illumination source therefore the analyser will not operate when the measurement cycle is in the stopped position What is a Spectrometer Standard A Spectrum Standard is the overall shape of the Spectra that is typical of the oil passing though the OIW-EX Series Analyzer. Figure 7 show two spectra from oil samples, if Sample 1 was set as the Spectrometer Standard then an alarm can be raised when Sample 2 is encountered because its shape does not match the Spectrometer Standard Spectra From Two Oil Samples Relative Intensity Sample 1 Sample Wave length (Nm) Figure 6. Spectra from Two Oil Samples Tel: +44(0) FAX +44(0) Page 12 of 33
13 Spectrometer Standard Creation Process Before you start to create a Spectrometer Standard you need to specify the number of Spectra you wish to form the Standard. This can be done with the Standard Size control. Once you are happy with the standard size a click on the Create Standard button will start the process; see Figure 7. The number of samples used to create the Standard means that the Standard is more representative of the overall shape of the samples passing though the analyzer. The default minimum of 5 will be fine in most cases. A new control Sample remaining until standard set will appear; this will be decremented each time a sample is taken; see Figure 8. Either leave for scheduled to run or to take a spectrometer standard just click the Take Spectra button; see Figure 9. Repeat this process until all samples have been taken, see Figure 11 Figure 7. Starting the Create Standard Process Figure 8. Sample remaining until standard set Figure 9. Take Spectra Button Figure 10. Sample remaining until standard set decremented Figure 11. Starting the Create Standard Process Tel: +44(0) FAX +44(0) Page 13 of 33
14 2.5 Spectrum Reading Cycle Explained As with the oil detection system the spectrum analyser requires the laser light as an illumination source therefore the analyser will not operate when the measurement cycle is in the stopped position. The spectrum analyser can take a reading based on any one of three conditions: The OIW System software periodically requests a reading based on a user selectable time period; The PPM level rises above the User Set trigger level; The user manually requests a reading. Each of these trigger conditions will be discussed in more detail below but the reading cycle remains the same for each condition. The user can have any combination of trigger conditions including all conditions at the same time i.e. the system can be set to trigger a reading every hour and trigger a reading if 100ppm is exceeded and select a manual reading. Note: only one reading will be taken at a time Measuring Cycles Spectrum Operation The OIW EX-1000 can be set to take a spectrum analyser reading at regular Measuring Cycles throughout the day, see the User Handbook for OIW EX-100 for details about Measuring Cycles. To access this option navigate to the Configuration Options tab, click the Schedule button and select the Spectrometer tab on the Schedule Configuration window. You may change the frequency at which Spectra are taken by using the Spectrometer reading taken every XX Measurement Cycles control, Figure 12. Figure 12. Scheduled Auto Settings Tel: +44(0) FAX +44(0) Page 14 of 33
15 With the Spectrometer reading taken every XX Measurement Cycles set to 0; no Spectra will be taken based on Measuring Cycles. With Spectrometer reading taken every XX Measurement Cycles set to 1; a Spectra will be taken every time a Measuring Cycle Starts PPM Level Triggered Spectrum Operation The OIW EX-1000 can be set to take a spectrum analyser reading when the ppm reading exceeds a user set ppm level. To access this option navigate to the Configuration Options tab, click the Oil Type button and select the Spectrometer Settings tab on the Oil Type Configuration window, Figure 13. The Level Trigger Value allows any ppm level to be entered in the range 0 to If a value of 0 is entered ppm level spectrum readings will not be taken as a value of 0 (zero) disables this option. Figure 13. Trigger Level Settings Manual Spectrum Operation With the measurement cycle started the Take Spectra button will be active and can be selected at any time to trigger a spectrum analysis of the produced water at that time. Tel: +44(0) FAX +44(0) Page 15 of 33
16 2.6 Spectrum Control Options The spectrum analyser three parameters that control the quality of the Spectra: Smoothing, Averaging, and Integration Time. To access this option navigate to the Configuration Options tab, click the Schedule button and select the Spectrometer Settings tab on the Schedule Configuration window, see Figure 14. Figure 14. Spectrum Control Options Spectrum Smoothing Smoothing specifies the number of readings on either side of a particular reading to average across an entire spectral acquisition. This method averages a group of adjacent detector elements. A value of three, for example, averages each data point with three points (or bins) to its left and three points to its right. The greater this value, the smoother the data and the higher the signal-to-noise ratio. However, if the value entered is too high, a loss in spectral resolution results Spectrum Averaging Smoothing specifies the number of spectra to average for the specified spectra output. A higher value for this parameter provides a better signal-to-noise (S:N) ratio. Tel: +44(0) FAX +44(0) Page 16 of 33
17 2.6.3 Spectrum Integration Time Integration Time specifies the length of the spectral acquisition in milliseconds for the spectrometer. The integration time of the spectrometer is analogous to the shutter speed of a camera. The higher the value specified for the integration time, the longer the detector "looks" at the incoming laser light. The three integration times relate to the different integration time available to avoid clip the signal. If IT1was set to 600ms, IT2 was set to 300ms and IT3 set to 200ms. The OIW EX 1000 software would take a Spectra using IT1 and check for Spectral clipping. If Spectral clipping occurred with IT1 then the OIW EX 1000 software would take a Spectra using IT2 and check for Spectral clipping. If Spectral clipping occurred with IT2 the OIW EX 1000 software would take a Spectra using IT3. Example of Different Integration Times IT1 = 600ms IT2 = 300ms Light Intensity IT3 = 200ms Wave length nm Figure 15. Spectral Clipping and Integration Times If IT1, IT2 and IT3 are set to the same value then the OIW EX 1000 software does not attempt to resolve Spectral clipping. Tel: +44(0) FAX +44(0) Page 17 of 33
18 2.7 Spectrum Control Options The spectrum analyser has three parameters that control the quality of the Spectra: Smoothing, Averaging, and Integration Time. To access this option navigate to the Configuration Options tab, click the Schedule button and select the Spectrometer Mask Settings tab on the Schedule Configuration window, see Figure 16. Figure 16. Spectrum Control Options Water Status off/on Water Status Alarm off Water Status Alarm on Figure 17. Spectrum Control Options Tel: +44(0) FAX +44(0) Page 18 of 33
19 2.7.2 Changing % Mask Tolerance Figure 18. Changing the % Mask Tolerance Changing the Lower Wavelength Figure 19. Changing the Lower Wavelength Tel: +44(0) FAX +44(0) Page 19 of 33
20 2.7.4 Changing the Upper Wavelength Figure 20. Changing the Upper Wavelength Changing the Upper Wavelength Figure 21. Changing the Lower Wavelength Tel: +44(0) FAX +44(0) Page 20 of 33
21 2.7.6 Changing the % Above Line Figure 22. Changing the Lower Wavelength Tel: +44(0) FAX +44(0) Page 21 of 33
22 2.8 Spectrum Log Files The Spectrum logs can be found in a folder named Spec_Logs within the OIWLogs folder as detail in the Data Logging Handbook please refer to that handbook for details of how to access the logs. Each spectrum data log has a unique file name as shown in the example below, Figure 23. Figure 23. Spectrum Data Logs Folder Tel: +44(0) FAX +44(0) Page 22 of 33
23 The file SN _Mar_09-08_07_58_Thu_OIW_Spectra_DATA_31.3ppm.csv may be used to show the filename format, SN _Mar_09-08_07_58_Thu_OIW_Spectra_DATA_31.3ppm.csv The serial number of the OIW unit, in this example SN SN _Mar_09-08_07_58_Thu_OIW_Spectra_DATA_31.3ppm.csv The date the spectra was taken, in this example 5 th March 2009 SN _Mar_09-08_07_58_Thu_OIW_Spectra_DATA_31.3ppm.csv The time the spectra was taken, in this example 08:07:58 SN _Mar_09-08_07_58_Thu_OIW_Spectra_DATA_31.3ppm.csv The day of the week the spectra was taken, in this example Thursday SN _Mar_09-08_07_58_Thu_OIW_Spectra_DATA_31.3ppm.csv The type of OIW file, in this example Spectra Data for an Oil-in-Water sensors SN _Mar_09-08_07_58_Thu_OIW_Spectra_DATA_31.3ppm.csv The measured value when the spectra was taken, in this example 31.3 parts per million SN _Mar_09-08_07_58_Thu_OIW_Spectra_DATA_31.3ppm.csv The type of the file. As with all of the OIW data logs the spectrum data logs are text based files output in.csv format (comma separated values). This means that they can be opened in a plain text editor such as Notepad (included with Windows) or more sophisticated mathematical analysis tools such as Microsoft s Excel application, see Figure 24. Figure 24. Spectrum Data Log File Opened in Excel The format of the spectrum data log is as follows: The first line is a header line show the oil ppm level in the water at the time the Spectra was taken and measurement limit. The second line is a header line to identify the two columns that follow. In addition this line holds some status information about the spectrum reading which is for Advanced Sensors Ltd use only. The remaining lines list the wavelength and relative light level reading, as partially shown in Figure 24 above. Tel: +44(0) FAX +44(0) Page 23 of 33
24 3 Using SpAn SpAn (Spectrum Analyser) is Advanced Sensors software tool used to view the Spec log files. Note: as mention previously the files can be view with a variety of tools such as NotePad and analysis can be done in programs like Microsoft s Excel program. 3.1 Starting SpAn To start SpAn simply locate the SpAn icon on the desktop, shown below, Figure 25. Once the software has started the screen will be as shown, Figure 26. Figure 25. SpAn Icon Figure 26. Startup Screen Tel: +44(0) FAX +44(0) Page 24 of 33
25 3.2 Loading a spectrum log File To load a file select the button marked Click to Load Data highlighted in red, just below the centre of the screen, Figure 27. When this is clicked a standard Windows load dialogue box will appear. Simply navigate to the data directory and select a data log file, as shown below, Figure 27. Figure 27. Loading a Spectrum Data File Tel: +44(0) FAX +44(0) Page 25 of 33
26 When the file loads the red button will change to display the filename it has loaded (Figure 28 ) and the data within that file will be displayed in the graph area (Figure 28 ). In addition the Hide buttons option will be enabled (Figure 28 ) (prior to loading a file this option was disabled, as seen above Figure 27), and the next button in line (blue button (Figure 28 )) will also become enabled. Figure 28. File Loaded Tel: +44(0) FAX +44(0) Page 26 of 33
27 Once the second (blue) button has been enable the process can be repeated to load a second file into SpAn and in turn the third (green) button will be enabled, allowing the user to load a third file etc. up to six files can be loaded simultaneously into SpAn for analysis and comparison. Figure 29 below, shows two spectrum data loaded into SpAn. The colour of each line on the graph corresponds with the colour of the file name on the Load button. Figure 29. Multiple Data Files Loaded Tel: +44(0) FAX +44(0) Page 27 of 33
28 3.3 Auto Scaling When a file is loaded the graph is drawn such that it fills the graph area, as was shown in Figure 27 above. If a second graph (or subsequent graph) is loaded which is larger than the previous graph then the graph scale will adjust to fill the graph area with the largest graph, as seen in. Figure 29 above note how the blue line has been scaled to fill the graph area and the red line has been reduced to proportionately compare against the blue line. If the user wishes to see the red line fill the screen then they can hide all larger graph lines by selecting their Hide button s as can be seen in Figure 30 below. Notice how the blue Hide button has changed to read Unhide to highlight that a graph has been loaded, but has been hidden. Figure 30. Using the Hide Button Tel: +44(0) FAX +44(0) Page 28 of 33
29 3.4 Identifying Points on the Graph To identify a point on the graph the user can select a point on the graph by clicking the mouse pointer any where on the graph page, see below Figure 31. Doing this will update the display area at the top of the SpAn screen Figure 31 to identify the Wavelength (x axis) and the Light Intensity (y-axis). Figure 31. Selecting points on the Graph 3.5 Saving/Loading Spectral Data File Sets To aid quick recall of a reading or set of readings once loaded the user can save the filename set this can be done by selecting File Save (or by pressing CTRL S), as shown below (Figure 32 ). This will bring up a standard Windows Save As window. The user can navigate to an area of their choice and enter a file name that best describes the file set, shown in Figure 32. Once saved the file set name will be displayed at the bottom of the screen, Figure 32, where previously No File Loaded was displayed. Figure 32. Saving a File Set Tel: +44(0) FAX +44(0) Page 29 of 33
30 Once a file set has been saved it can be loaded back into SpAn by selecting the File Load from the top tool bar, see Figure 33, or by pressing CTRL L. This will bring up standard windows Open window and will list all file set filenames previous store, as shown below, Figure 34. Selecting a file set name and clicking on the Open button will re-display the set of spectrum files previously saved. Figure 33. Loading a File Set Figure 34. Loading a File Set Tel: +44(0) FAX +44(0) Page 30 of 33
31 3.6 Printing The SpAn graph area can be output to a printer by selecting the File Print from the top tool bar, see Figure 35, or by pressing CTRL P. This will bring up a standard windows print menu where the user can select the printer and adjust printer options. In addition to this option there are two other options Print Setup and Print Preview these are standard windows settings which allows the user to adjust various aspects of the printout. Figure 35. Print Options Tel: +44(0) FAX +44(0) Page 31 of 33
32 4 Errors with EX1000 When the unit is started the OIW software will look for the presence of the spectrum analyser. If the device is not found then a message box will appear highlighting that a Spectrometer was not found, see Figure 36, and a system log message will be logged. Should this ever happen, please contract your Advanced Sensors agent or Advanced Sensors directly. Figure 36. Could not find spectrometer. Tel: +44(0) FAX +44(0) Page 32 of 33
33 5 Appendix 1 OIW-EX Series Contact Details Customer Liaison Sales & Marketing Tel. +44(0) sales@advancedsensors.co.uk Advanced Sensors Headquarters Advanced Sensors Ltd 8 Meadowbank Road Carrickfergus BT38 8YF UK Tel: +44 (0) Fax: +44 (0) Tel: +44(0) FAX +44(0) Page 33 of 33
OIW-EX Series of Oil in Water Monitors
OIW-EX Series of Oil in Water Monitors Remote Access Handbook Document code: OIW-HBO-0004 Version: EX-003 Page 1 of 17 Document History Version A Draft...First draft separated from installation and User
More informationOIW-EX Series of Oil In Water Analyzers MiView Handbook Document code: OIW-HBO-0013 Version: EX July 2013
OIW-EX Series of Oil In Water Analyzers MiView Handbook Document code: OIW-HBO-0013 Version: EX-004 17 July 2013 Tel: +44 (0) 28 9332 8922 Document History Change No. Version No. Description Month & Year
More informationOIW-EX Series of Oil in Water Monitors
OIW-EX Series of Oil in Water Monitors Data Logging Handbook Document code: OIW-HBO-0003 Version: EX-002 www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 1 of 50 Document
More informationUSER HANDBOOK: OIW - SA IN-LINE PROBE SERIES OIL IN WATER ANALYZERS for SAFE AREA APPLICATIONS. World s Best Oil in Water Analyzers
World s Best Oil in Water Analyzers USER HANDBOOK: OIW - SA IN-LINE PROBE SERIES OIL IN WATER ANALYZERS for SAFE AREA APPLICATIONS DOCUMENT CODE: 0IW - HBO - 0016 VERSION: SA-00a TABLE OF CONTENTS TABLE
More informationUser Guide File Transfer Scheduler. LINAX Series LINAX A310 CAMILLE BAUER
LINAX Series User Guide File Transfer Scheduler CAMILLE BAUER LINAX A310 Use of Instructions Warning. An instruction that draws attention to the risk of injury or death. Note. Clarification of an instruction
More information67 Series Spectrophotometer PC Software
67 Series Spectrophotometer PC Software Instruction Manual 670 004/Rev D/04-17 IMPORTANT Please ensure the SD Card is fitted into the socket as detailed in the image below. -------------------------------------------------------------------------------------------------------------------------
More informationManual. User Reference Guide. Analysis Application (EMG) Electromyography Analysis
Phone: (888) 765-9735 WWW.MINDWARETECH.COM User Reference Guide Manual Analysis Application Electromyography Analysis (EMG) Copyright 2014 by MindWare Technologies LTD. All Rights Reserved. 1 Phone: (614)
More informationModel FP-6500 Spectrofluorometer Instruction Manual. FP-6500 for Windows
Model FP-6500 Spectrofluorometer Instruction Manual FP-6500 for Windows P/N: 0302-9999 April 2000 Contents Safety Considerations...i Regulatory Statements... iii Preface... iv Installation Conditions...v
More informationINSTALLATION HANDBOOK:
World s Best Oil in Water Analyzers INSTALLATION HANDBOOK: IN-LINE PROBE INSTALLATION OIW - EX & OIW - SA SERIES OIL IN WATER ANALYZERS DOCUMENT CODE: OIW - HBO - 0012 VERSION: 2 TABLE OF CONTENTS TABLE
More informationFluorimeter User s Booklet
Fluorimeter User s Booklet 1) Verify that the instrument power and the computer are both off. Then turn on the lamp. The red indicator light will glow when the lamp is on. Turn on lamp switch here. This
More informationMindWare Electromyography (EMG) Analysis User Reference Guide Version Copyright 2011 by MindWare Technologies LTD. All Rights Reserved.
MindWare Electromyography (EMG) Analysis User Reference Guide Version 3.0.12 Copyright 2011 by MindWare Technologies LTD. All Rights Reserved. MindWare EMG 3.0.12 User Guide Internet Support E-mail: sales@mindwaretech.com
More informationStandard Operating Procedure for the Horiba FluroMax-4
Standard Operating Procedure for the Horiba FluroMax-4 Adapted from Horiba Operations Manual Created by Michael Delcau, Modified by Brian Lamp The Fluoromax is capable of making a variety of measurements.
More informationJasco FP-6500 Spectrofluorimeter Updated November 14, 2017
Jasco FP-6500 Spectrofluorimeter Updated November 14, 2017 Instrument instructions can be found at: http://academic.bowdoin.edu/chemistry/resources/instructions.shtml If you have any problems with the
More informationProcess Eye Professional. Recall
Process Eye Professional Recall Process Eye Professional Recall User Manual SP104010.101 August 2005 As part of our continuous product improvement policy, we are always pleased to receive your comments
More informationLINAX Series Videographic Recorders
User Guide 154534_8 LINAX Series Videographic Recorders DataManager Software Electrical Safety This instrument complies with the requirements of CEI/IEC 61010-1:2001-2 'Safety Requirements for Electrical
More informationWavy for PAX Ver. 4.0
Operation Manual Sequence Creation Software Wavy for PAX Ver. 4.0 SPEC70289 Version 4.0 Prepared: June 21, 2006 KIKUSUI ELECTRONICS CORPORATION 1/34 Contents Note Before contacting us to request repair,
More informationSIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Security information 1. Preface 2. Additional documentation 3
Security information 1 Preface 2 SIMATIC Process Control System PCS 7 Operating Instructions Additional documentation 3 Functions of the PCS 7 OS in process mode 4 PCS 7 OS process mode - user interface
More informationCITO2 Installation & User Instructions
CITO2 Installation & User Instructions DD 56107 Stoneridge Electronics Ltd 1. Installation...4 1.1. System Requirements...4 1.2. Installing CITO2...4 1.3. Uninstalling CITO2...4 2. Starting and closing
More informationVideographic Recorders
User Guide Supplement File Transfer Scheduler IM/SMFTS Issue 4 Videographic Recorders ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process
More informationSIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3
Preface 1 Additional documentation 2 SIMATIC Process Control System PCS 7 Operating Instructions Functions of the PCS 7 OS in process mode 3 PCS 7 OS process mode - user interface 4 System operator inputs
More informationWavy for PLZ-4W Ver. 4.0
Operation Manual Sequence Creation Software Wavy for PLZ-4W Ver. 4.0 Version 4.0 Prepared: June 21, 2006 KIKUSUI ELECTRONICS CORPORATION 1/35 Note Before contacting us to request repair, inspection, or
More informationCH142 Spring Spectrophotometers with Vernier Data Acquisition Software
Spectrophotometers with Vernier Data Acquisition Software The absorbance of a sample is given as A = log I o I, where I o is the intensity without sample present and I is the intensity with the sample
More informationPodium Plus Data Analysis Software. User Manual. SWIS10 Version
SWIS10 Version Issue 1.10 February 2005 Contents 1 Introduction 6 1.1 What is Podium Plus? 6 1.2 About This Manual 6 1.3 Typographical Conventions 7 1.4 Getting Technical Support 7 2 Getting Started 8
More informationAgilent ChemStation Plus
Agilent ChemStation Plus Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2004, 2006-2008 No part of this manual may be reproduced in any form or by any means (including electronic
More informationCVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro
CVI SPECTRAL PRODUCTS 111 Highland Drive Putnam CT, 06260 (860) 928-5834 SM32Pro 2.8.28 Table of Contents Warranty and Liability 1 Quick Start Installation Guide 2 System Requirements 3 Requirements for
More informationDeckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.
Deckblatt SIMATIC PCS 7 Application description June 2011 Applikationen & Tools Answers for industry. Industry Automation and Drive Technologies Service & Support Portal This article is taken from the
More informationPME 700 Demolition Stability Monitor
PME 700 Demolition Stability Monitor Operators Manual This guide describes operation of the PROLEC PME LIFTING AND MACHINE ENVELOPE SAFETY SYSTEM FOR CONSTRUCTION PLANT Model covered : PART No. MODEL
More informationFunasset Limited Foundry House Foundry Road Taunton Somerset TA1 1JJ. Tel: +44 (0) Fax: +44 (0) mailmarkup.com funasset.
Funasset Limited Foundry House Foundry Road Taunton Somerset TA1 1JJ Tel: +44 (0)1823 365864 Fax: +44 (0)1823 277266 mailmarkup.com funasset.com Copyright 2012 Funasset Limited. All rights reserved. Products
More informationUser s Guide. Valvova Oy
User s Guide Valvova Oy June 21, 2017 CONTENTS Contents 1 Timeline 2 1.1 Program startup......................................... 3 1.2 Calendar............................................. 3 1.3 Go to
More informationSIMATIC HMI. WinCC V7.0 SP1 Setting up a Message System. WinCC Alarm Logging 1. Message System in WinCC 2. Principles of the Message System
SIMATIC HMI WinCC V7.0 SP1 SIMATIC HMI WinCC V7.0 SP1 WinCC Alarm Logging 1 Message System in WinCC 2 Principles of the Message System 3 Configuring the Message System 4 Printout of the Online Help 11/2008
More informationRaman Lab - Laser 1 operation
Raman Lab - Laser 1 operation Cover limit switches cooling water supply optimate panel light control laser remote control sample stage Remote Shutter Control laser power supply WARNING! Never ever try
More informationUsing the Bruker Tracer III-SD Handheld X-Ray Fluorescence Spectrometer using PC Software for Data Collection
Using the Bruker Tracer III-SD Handheld X-Ray Fluorescence Spectrometer using PC Software for Data Collection Scott A Speakman, Ph.D Center for Materials Science and Engineering at MIT For assistance in
More informationDCN Simultaneous Interpretation. Software User Manual en LBB 3572
DCN en LBB 3572 GENERAL CONTENTS Chapter 1-1.1 About 1.2 Interpretation procedures Chapter 2 - Getting Started 2.1 Starting 2.2 Using Help Chapter 3 - Preparing for a Conference 3.1 The interpretation
More informationPSITRACK Software. User Guide
PSITRACK Software User Guide Authors: PSI Technics Version: 1.10.05.03 Status: Final Date: July 8, 2011 PSI Technics Ltd. Company Headquarter Germany Rudolf-Diesel-Str. 21a D-56220 Urmitz, Germany Tel
More informationSIMATIC HMI. Configuring Graphics Displays. Product Brief. Edition 12/01. Table of Contents. Introduction. Commissioning Operating Units
SIMATIC HMI Configuring Graphics Displays Table of Contents Introduction Commissioning Operating Units Product Brief Basic Steps for a Configuration Extend Configuration with Simple Elements Edition 12/01
More informationTable of Contents. Tops Digital Solutions DVS 2000 Series Users Manual Ver.2.0 2
DVS 2000 Series Table of Contents Ch. 1. Preface 4 How to Use This Guide... 4 Conventions 4 Related Documents... 4 Support.. 5 Safety Warnings and Information.. 5 Ch. 2. Overview. 6 Overview 6 Features..
More informationOutput Holder for MOD 30ML. Application Guide. Description and Application of 1726F Output Holder
Output Holder for MOD 30ML Application Guide Description and Application of 1726F Output Holder MicroMod Automation, Inc. The Company MicroMod Automation is dedicated to improving customer efficiency by
More informationMindWare Heart Rate Variability (HRV) Analysis User Reference Guide Version Copyright 2011 by MindWare Technologies LTD. All Rights Reserved.
MindWare Heart Rate Variability (HRV) Analysis User Reference Guide Version 3.0.14 Copyright 2011 by MindWare Technologies LTD. All Rights Reserved. MindWare HRV 3.0.14 User Guide Internet Support E-mail:
More informationWavy for PLZ-4W Ver. 5.3
T.Shimbo 14 8 6 Operation Manual Sequence Creation Software Y.Oyama 14 8 6 Wavy for PLZ-4W Ver. 5.3 Version 5.3 Prepared: August, 2014 KIKUSUI ELECTRONICS CORPORATION 1/38 Note Before contacting us to
More informationQuick Start Guide ZEN 2 core. Imaging Software
Quick Start Guide ZEN 2 core Imaging Software Table of Contents 1 Welcome 03 1.1 Introduction 04 1.2 Workflows 05 1.3 User Roles 06 1.4 Starting the Software and Logging In 07 2 Creating a Job Template
More informationSOFTWARE UPDATE NOTIFICATION SPRAYTEC SOFTWARE v3.30: PSS
SOFTWARE UPDATE NOTIFICATION SPRAYTEC SOFTWARE v3.30: PSS0024-11 Introduction This document details the release of software PSS0024-11: version 3.30 of the software for the Spraytec laser diffraction system.
More informationMultivariate Calibration Quick Guide
Last Updated: 06.06.2007 Table Of Contents 1. HOW TO CREATE CALIBRATION MODELS...1 1.1. Introduction into Multivariate Calibration Modelling... 1 1.1.1. Preparing Data... 1 1.2. Step 1: Calibration Wizard
More informationUSER GUIDE. Quick Start Guide to PT-Mapper Pro Version 5 or later. Revised August Map Editing Software for Local Councils
USER GUIDE Quick Start Guide to PT-Mapper Pro Version 5 or later Revised August 2015 Map Editing Software for Local Councils Pear Technology Services Ltd. 2015 Unit 31, Broadmarsh Business Centre, Harts
More informationFREEDOM-Pad Installation and Operation
FREEDOM-Pad Installation and Operation Quick Start Steps for installing FREEDOM-Pad Page 2 Desktop Install Overview Page 2 Mobile Device Installation Overview Page 2 Activating the Battery Page 2 Resetting
More informationSIMATIC HMI. WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started. Welcome 1. Icons 2. Creating a project. Configure communication
Welcome 1 Icons 2 SIMATIC HMI WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started Getting Started Creating a project 3 Configure communication 4 Configuring the Process Screens 5 Archiving and displaying
More informationDCN Synoptic Microphone Control. Software User Manual en LBB 3571
DCN en LBB 3571 GENERAL CONTENTS Chapter 1-1.1 About 1.2 What is a synoptic layout? 1.3 Controlling microphones Chapter 2 - Getting Started 2.1 Starting 2.2 Using Help Chapter 3 - Preparing for a Conference
More informationUser Manual Australia
User Manual Australia April 2009 EAZ0057B06A Rev. A Trademarks Acknowledgements Snap-on, ShopStream Connect, ETHOS, MODIS, SOLUS, SOLUS PRO, and Vantage PRO are trademarks of Snap-on Incorporated. All
More informatione-bridge Color Profile Tool Quick Start Guide
e-bridge Color Profile Tool Quick Start Guide 1 Contents 1. Installation... 3 1.1. Installing the e-bridge Color Profile Tool Software... 3 1.1. Removing the e-bridge Color Profile Tool... 4 1.2. Installing
More informationSoftware Installation and Quick Start Guide. PowerMax-Pro PC
Software Installation and Quick Start Guide PowerMax-Pro PC Software Installation and Quick Start Guide PowerMax-Pro PC 27650 SW 95th Ave. Wilsonville, OR 97070 This document and software is copyrighted
More informationPROCESS ANALYSERS. SERVOTOUGH FluegasExact Gas Analyser. QuickStart Manual. Part Number: D Revision: 1 Language: UK English
PROCESS ANALYSERS SERVOTOUGH FluegasExact Gas Analyser QuickStart Manual Part Number: 02700003D Revision: 1 Language: UK English This page intentionally blank TABLE OF CONTENTS 1. INTRODUCTION............................................
More informationACTIVE Net Insights user guide. (v5.4)
ACTIVE Net Insights user guide (v5.4) Version Date 5.4 January 23, 2018 5.3 November 28, 2017 5.2 October 24, 2017 5.1 September 26, 2017 ACTIVE Network, LLC 2017 Active Network, LLC, and/or its affiliates
More informationIMSERC NMR MANUAL 02: Basic Processing of Varian 1D NMR Data
IMSERC NMR MANUAL 02: Basic Processing of Varian 1D NMR Data Last updated: July 15, 2011 by Josh Kurutz This manual describes how to process NMR data on the offline processing computer in the IMSERC lab
More informationCal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester. Users Guide. Rev 3.1
Cal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester Users Guide Rev 3.1 Contents... 1 Quick Start Guide... 2 Selecting a Test Specification... 3 Clearing Traces... 4 Saving Traces...4 Loading
More informationRaman Spectrometer Installation Manual
RI Raman Spectrometer Instruction Manual Application software (included in standard configuration) Connection RI RAMAN is recognized by Windows operational system as standard HID device. That is why there
More informationRMS Monitoring Software System Operation
System Operation 2016 ROTRONIC AG Bassersdorf Switzerland Contents Contents... 2 1 Overview... 3 1.1 System Requirements... 3 1.1.1 Browser... 3 2 System Login... 4 3 Data Views... 5 3.1 Alarm Symbols...
More informationINSTALLATION MANUAL for the Application ihc-mirf
INSTALLATION MANUAL for the Application ihc-mirf Contents Introduction 3 Installing the application on a mobile phone 3 Settings 4 Control 12 Introduction The applications ihc-mirf (for mobile phones with
More informationAGENT VIEW Taking calls
AGENT VIEW Taking calls Synthesys Taking Call 1 Introduction This chapter provides an overview of the Agent module, used to run callflows both in a live call situation, and in a testing environment. When
More informationAgilent MassHunter Metabolite ID Software. Installation and Getting Started Guide
Agilent MassHunter Metabolite ID Software Installation and Getting Started Guide Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including
More informationRITIS Training Module 9 Script
RITIS Training Module 9 Script Welcome to the Regional Integrated Information System or RITIS Module 09 CBT. To begin, select the start button or press Shift+N on your keyboard. This training module will
More informationUser Manual Data-Logger Software
Data-Logger Software ESCO MEDICAL MRI-6A10/XQ-1 Version 1.1 Rx only 1 of 29 ESCO MEDICAL Esco Micro Pte Ltd 21 Changi South Street 1 Singapore 486777 Tel. : +65 6542 0833 Fax : +65 6542 5732 / 6546 2913
More informationSpectrometer Visible Light Spectrometer V4.4
Visible Light Spectrometer V4.4 Table of Contents Package Contents...3 Trademarks...4 Manual Driver and Application installation...5 Manual Application Installation...6 First Start of the Application...8
More informationUniversity of Minnesota Nano Fabrication Center Standard Operating Procedure
Equipment Name: University of Minnesota Nano Fabrication Center Coral Name: hs-scope Revision Number: 1.5 Model: HS200A Revisionist: M. Fisher Location: Bay 1 Date: 9/12/2013 1 Description The Hyphenated
More informationOperator Manual. Version 2.813
Operator Manual Version 2.813 June, 2015 Content Basic definitions and abbreviations...4 Get started...5 Change of displaying units layout...7 Scale change...7 Content...8 Content display...8 Software...8
More informationOutlook - an Introduction to Version 2003 Table of Contents
Outlook - an Introduction to E-mail Version 2003 Table of Contents What is Outlook Starting Outlook The Navigation Pane Getting Help Creating and Sending a Message Using the College Exchange Directory
More informationTotalLab TL100 Quick Start
TotalLab TL100 Quick Start Contents of thetl100 Quick Start Introduction to TL100 and Installation Instructions The Control Centre Getting Started The TL100 Interface 1D Gel Analysis Array Analysis Colony
More informationLiving Image Software
Living Image Software User s Manual Version 3.1 2002-2008 Xenogen Corporation. All rights reserved. PN 124908 Xenogen Corporation 68 Elm Street Hopkinton, MA 01748 USA 1.877.522.2447 (US) 1.508.435.9500
More informationSC-01 Data Logger Management Program Operator s Manual
SC-01 Data Logger Management Program Operator s Manual Part Number: 71-0138RK Revision: P1 Released: 9/12/07 www.rkiinstruments.com Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by
More informationLegacy Client Chart (LCC) Installation Guide for Purkinje System
Legacy Client Chart (LCC) Installation Guide for Purkinje System A Guide to Run and Configure the Legacy Client Chart (LCC) Solution For questions about using this guide please contact IMS@aohc.org Table
More informationVersion 4.0 of D-BIT Fixed Assets has many enhancements and is typical of our commitment to continual development of our products.
D-BIT SYSTEMS (Pty) Ltd RegNo: 87/0332407 7 Boskruin Business Park Bosbok Rd Boskruin South Africa PO Box 1950 Randpark Ridge 2156 South Africa Tel: +27 11 791-4550 Fax: +27 11 791-4566 Web: www.d-bit.co.za
More informationSTS Spectrometer Getting Started
STS Spectrometer Getting Started STS is a family of compact, low-cost spectrometers ideal for embedding into OEM devices. STS provides remarkable performance for a spectrometer of its size (just 40 mm
More informationPC Audit Trail Manager Software PCAT. B Operating Manual 02.04/
PC Audit Trail Manager Software PCAT B 95.5097.0 Operating Manual 02.04/00420786 Contents 1 Introduction 5 1.1 Preface... 5 1.2 Arrangement of the documentation... 6 1.3 Typographical conventions... 6
More informationONMS. Optical Network Management System
ONMS Optical Network Management System JDSU Enabling Broadband and Optical Innovation Improving the world of communications Around the globe, communications companies look to JDSU for the best in effective,
More informationtesto Comfort Software Professional 4 Instruction manual
testo Comfort Software Professional 4 Instruction manual 2 1 Contents 1 Contents 1 Contents...3 2 About this document...5 3 Specifications...6 3.1. Use...6 3.2. System requirements...6 4 First steps...7
More informationRMS Monitoring Software System Operation
RMS Monitoring Software System Operation 2017 ROTRONIC AG Bassersdorf Switzerland 2017 ROTRONIC AG Bassersdorf Switzerland Page 2 of 27 Contents Contents... 3 1 Overview... 4 1.1 System Requirements...
More informationClarity Hardware. Duratec DDT 3200 USB. Code/Rev.: M064/24C 27 September 2006
Clarity Hardware Clarity Duratec Controls DDT 3200 Duratec DDT 3200 USB DETECTOR ENG Code/Rev.: M064/24C 27 September 2006 Phone: +420-251 013 400 DataApex Ltd. 2006 Fax: +420-251 013 401 Podohradská 1
More informationMAAR MLS Transition Guide
MAAR MLS Transition Guide Contents 1. Introduction... 2 2. Saved Searches and Auto-Notifications... 3 2.1 Saved Searches... 3 2.2 Notifications... 6 3. MLXchange Agent Web Pages... 9 3.1 MLXchange AWP
More informationChromatography Software Training Materials. Contents
Chromatography Software Training Materials This document contains information on how to build a method, start the instrument to acquire data, and then process the data using the Galaxie Program. You will
More informationSecure Web Appliance. Basic Usage Guide
Secure Web Appliance Basic Usage Guide Table of Contents 1. Introduction... 1 1.1. About CYAN Secure Web Appliance... 1 1.2. About this Manual... 1 1.2.1. Document Conventions... 1 2. Description of the
More informationQUICK START. DevCom2000 User Manual
QUICK START DevCom2000 uses Device Descriptions (DDs) to access data stored in the memory of the smart field device. These DDs are developed by the manufacturer for their products and, in turn, distributed
More informationSoftware User's Guide
Software User's Guide Brother QL-series The contents of this guide and the specifications of this product are subject to change without notice. Brother reserves the right to make changes without notice
More informationTurnitin assignments are added from the course s home page. To open the course home page, click on the course from the Moodle start page.
Guides.turnitin.com Turnitin Assignment Assignment Submission Dates Submitting Papers on Behalf of Students Viewing the Turnitin Submission Inbox Glossary 1 Turnitin Assignment Turnitin assignments are
More informationThe BLR Employee Handbook Builder allows you to create your own customized employee handbook. Benefits include:
Introduction to BLR s Employee Handbook Builder The BLR Employee Handbook Builder allows you to create your own customized employee handbook. Benefits include: Ability to work on a handbook from any computer
More informationPodium Data Analysis Software. User Manual. SWIS10 Version
SWIS10 Version Issue 1.00 March 2003 Contents 1 Introduction 5 1.1 What is Podium? 5 1.2 About This Manual 5 1.3 Typographical Conventions 6 1.4 Getting Technical Support 6 2 Getting Started 7 2.1 System
More informationOperator Manual SCADA Operator Manual. Operator Manual. SCADA Procedures OPERATOR MANUAL SCADA A Page 1 of 39
Operator Manual SCADA Procedures OPERATOR MANUAL SCADA 73152-482-00001 A Page 1 of 39 Original Instructions Disclaimer It is essential that you understand the information in this document. This document
More informationOperating Procedure for Horiba Raman Microscope
Operating Procedure for Horiba Raman Microscope SAFETY Be aware of Laser radiation at all times! Do not remove the covers of the instrument. Components are supplied with 110V electric source. Do not touch
More informationTurnitin Moodle Direct Integration Instructor User Manual. Version: Updated August 28, Turnitin Moodle Integration Manual: 1
Turnitin Moodle Direct Integration Instructor User Manual Version: 2.1.0 Updated August 28, 2010 Turnitin Moodle Integration Manual: 1 Contents Instructor User Manual 1 Creating a Turnitin Assignment 3
More informationOOIBase32 Spectrometer Operating Software Operating Instructions
Rev 2.21 12092003 OOIBase32 Spectrometer Operating Software Operating Instructions Offices: Ocean Optics, Inc. 380 Main Street, Dunedin, Fla., USA Phone 727.733.2447 Fax 727.733.3962 8:30 a.m.-6 p.m. EST
More informationDataStudio Starter Manual
Instruction Manual Manual No. 012-08107 DataStudio Starter Manual Manual No. 012-08107 Manual No. 012-08107 DataStudio Starter Manual Introduction What is DataStudio? DataStudio is a data acquisition,
More informationIMS Client Operation Guide Version V1.1 Date
Version V1.1 Date 2015-10-20 About This Document About This Document About This User Manual Please note the following points before using this user manual: This user manual is intended for persons who
More informationQuick Start Guide: Welcome to OceanView
Quick Start Guide: Welcome to OceanView Contents: Ctrl + Click a Topic Below for More Information Introduction to OceanView... 3 Welcome Screen... 3 Data Window... 3 Schematic View... 3 Persistence...
More informationHH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual
HH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual CONTENTS 1. GENERAL DESCRIPTION... 2 2. SAFETY INFORMATION... 2 3. FEATURES... 2 4. SPECIFICATIONS...
More informationNeed help? Call: / DOCMAIL: PRINT DRIVER USER GUIDE
Need help? Call: 01761 409701 / 409702 DOCMAIL: PRINT DRIVER USER GUIDE February 2018 1 GETTING STARTED Display settings Please be aware that to allow for the Print Driver to function efficiently, there
More informationColor iqc and Color imatch Managing Electronic Submissions Guide
Color iqc and Color imatch Managing Electronic Submissions Guide Version 8.0 July 2012 Color iqc contains many features designed to help you manage and participate in any electronic supply chain management
More informationAn Introductory Guide to SpecTRM
An Introductory Guide to SpecTRM SpecTRM (pronounced spectrum and standing for Specification Tools and Requirements Methodology) is a toolset to support the specification and development of safe systems
More informationContents. Batch & Import Guide. Batch Overview 2. Import 157. Batch and Import: The Big Picture 2 Batch Configuration 11 Batch Entry 131
Batch & Import Guide Last Updated: 08/10/2016 for ResearchPoint 4.91 Contents Batch Overview 2 Batch and Import: The Big Picture 2 Batch Configuration 11 Batch Entry 131 Import 157 Configure Import File
More informationTraceFinder Analysis Quick Reference Guide
TraceFinder Analysis Quick Reference Guide This quick reference guide describes the Analysis mode tasks assigned to the Technician role in the Thermo TraceFinder 3.0 analytical software. For detailed descriptions
More informationDigia Client. User Manual
Digia Client User Manual Copyright Disclaimer Trademarks and patents Software license agreement Intended use Regulatory Copyright 2005, GE Security Inc. All rights reserved. This document may not be copied
More informationBWSpec 4 Software User Manual. 19 Shea Way, Newark, DE Tel: (302) Fax: (302) Web:
BWSpec 4 Software User Manual 290020235-G (09/16/2015) Copyright 2015 B&W Tek, Inc. Table of Contents 1 Introduction 1 2 Installation 1 2.1 Supported Operating Systems 1 2.2 Minimum System Requirements
More informationRITIS Training Module 4 Script
RITIS Training Module 4 Script Welcome to the Regional Integrated Information System or RITIS Module 04 CBT. To begin, select the start button or press Shift+N on your keyboard. This training module will
More informationUser s Manual Type DTWG Web Server Version 1.1
User s Manual Type DTWG Web Server Version 1.1 Russelectric Inc. South Shore Park, Hingham, Massachusetts 02043 Service 800 654-3020 www.russelectric.com 90E1730002 rev. A03 Table of Contents SECTION
More information