(Above 100km Distance) (Streetlight Pole) (Above 100km Distance) (Streetlight Pole)

Size: px
Start display at page:

Download "(Above 100km Distance) (Streetlight Pole) (Above 100km Distance) (Streetlight Pole)"

Transcription

1 Part 9 Miscellaneous Drawing Register Number Description M1-1 SSN Network Device with LV Aerial Supply (ABC) Arrangement M1-2 SSN Network Device with LV Aerial Supply Arrangement M1-3 SSN Network Device with LV Aerial Supply (on HV Pole) Arrangement M1-4 SSN Network Device with Street Light Supply Arrangement M1-5 M1-6 M1-7 SSN Network Device with LV Kiosk (Type-1) Supply Arrangement (Above 100km Distance) (Power Pole) SSN Network Device with LV Kiosk (Type-1) Supply Arrangement (Above 100km Distance) (Streetlight Pole) SSN Network Device with LV Kiosk (Type-1) Supply Arrangement (Above 100km Distance) (Streetlight Pole) M3-1 Pole Top Switch or Isolator Ground Clearing Details M3-2 Expulsion-Type Dropout Fuse Ground Clearing Details M4-1 Third Party Electrical Attachment with LV Aerial Supply (ABC) Arrangement M4-2 Third Party Electrical Attachment with LV Aerial Supply Arrangement M4-3 Third Party Electrical Attachment with LV Aerial Supply (on HV Pole) Arrangement M4-4 Third Party Electrical Attachment with Street Light Supply Arrangement AS/NZS AS/NZS Clearances to ground and areas remote from building, railways and navigable waterways Spacing of conductors Horizon Power Corporation

2 WARNING THIS ANTENNA IS EARTHED TO ISOLATE FROM EARTH DISCONNECT ANTENNA CABLE AT CONTROL BOX. REMOVE ANTENNA IF WORK AREA IS OBSTRUCTED. RESTORE WHEN FINISHED R8-4 N PH 6mm 2C XLPE 20mm FLEXIBLE CONDUIT FOR MECHANICAL PROTECTION OF CABLES NOTE 2 (1PH-N) CB TOP OF BRACKET NOTE 1 L N L N A N E AERIAL SUPPLY SSN DEVICE NOTES: 1. USE 2 x 32mm BANDIT STRAPS FOR STEEL POLES, FOR EXISTING WOOD POLES USE 2 x M16 x 400mm BOLTS. 2. 1PH CB WITH "NEUTRAL FEED THROUGH POLE". SECURE CB TO POLE USING 20mm BANDIT STRAPS (STEEL) OR 2 x M12 BOLTS (WOOD) CIRCUIT BREAKER CUT-OUT DISTRIBUTION CONSTRUCTION STANDARDS OPERATIONS STRUCTURE - 9.5m SSN NETWORK DEVICE WITH LV AERIAL SUPPLY (ABC) ARRANGEMENT REVISION DATE B MAY 2014 DRAWING No. M1-1

3

4

5 EXISTING STREET LIGHT POLE OUTREACH JOINTING NOTE TOP OF BRACKET mm FLEXIBLE CONDUIT FOR MECHANICAL PROTECTION OF CABLES 2.5mm 2C+E NOTE 2 NOTE 5 A N E LV AC SUPPLY - SEE NOTE 3 (DOUBLE INSULATED CABLE) A N E EXISTING TO LUMINAIRE (DOUBLE INSULATED CABLE) A A N A N E NOTE 4 EXISTING LV SUPPLY STREET LIGHT CUT-OUT DETAIL NOTE 3 NOTES: 1. USE 2 x 32mm BANDIT STRAPS FOR STREET LIGHT POLES. 2. EXTEND THE LV AC SUPPLY FROM STREET LIGHTING POLE CUT-OUT TO ACCESS POINT/RELAY. 3. STREET LIGHT CUT-OUT WILL NEED TO COMPLY WITH NEW STANDARD. 4. ADD 5 AMP FUSE ON CUT-OUT FOR NEW CIRCUIT TO AP/RELAY. 5. DRILL A HOLE TO FIX 20mm CONDUIT GLAND. DISTRIBUTION CONSTRUCTION STANDARDS OPERATIONS STRUCTURE - STREET LIGHT POLE SSN NETWORK DEVICE WITH STREET LIGHT SUPPLY ARRANGEMENT REVISION DATE A DRAWING No. M1-4

6 WARNING THIS ANTENNA IS EARTHED TO ISOLATE FROM EARTH DISCONNECT ANTENNA CABLE AT CONTROL BOX. REMOVE ANTENNA IF WORK AREA IS OBSTRUCTED. RESTORE WHEN FINISHED EXISTING POWER POLE (LV OH BARE OR LV OH AB CABLE) R11-1 (AERIAL) N PH 2.5mm 2C+E CABLE 0.6/1kV CO-AXIAL CABLES 2500 NOTE 1 ANTENNAS (WAN & NAN) TOP OF BRACKET NOTE 3 ACCESS POINT/ RELAY A N E L N L N A N E BATT KIOSK A N E LV AC SUPPLY SEE NOTE 3 CIRCUIT BREAKER DETAIL MCB NOTE 2 (SEE DETAIL) ACCESS POINT SURGE PROTECTOR CO-AXIAL CABLES NOTES: 1. USE 2 x 32mm BANDIT STRAPS FOR STEEL POLES. FOR EXISTING WOOD POLES USE 2 x M16 x 400mm BOLTS. 2. 1PH CB WITH "NEUTRAL FEED THROUGH POLE" MTD IN KIOSK. 3. EXTEND THE LV AC SUPPLY FROM LV O/H BARE (OR LV O/H ABC) TO CB IN LV KIOSK AND THEN TO ACCESS POINT/RELAY. STRUCTURE - 9.5M POWER POLE REVISION DATE A DISTRIBUTION CONSTRUCTION STANDARDS OPERATIONS DRAWING No. SSN NETWORK DEVICE WITH LV KIOSK (TYPE-1) SUPPLY M1-5 ARRANGEMENT (ABOVE 100km DISTANCE)

7 EXISTING STREET LIGHT POLE OUTREACH JOINTING 1000 CO-AXIAL CABLES TOP OF BRACKET NOTE 1 ANTENNAS (WAN & NAN) ACCESS POINT/ RELAY L A N E N L N A N E A N E NOTE 4 LV AC SUPPLY SEE NOTE 3 CIRCUIT BREAKER DETAIL KIOSK BATT MCB NOTE 2 (SEE DETAIL) ACCESS POINT CO-AXIAL CABLES LV UG SUPPLY 2.5mm 2C+E CABLE 0.6/1kV SURGE PROTECTOR NOTES: 1. USE 2 x 32mm BAND-IT STRAPS FOR STREET LIGHT POLES. 2. 1PH CB WITH "NEUTRAL FEED THROUGH POLE". MTD IN KIOSK. 3. EXTEND THE LV AC FROM UG SUPPLY TO CB IN LV KIOSK AND THEN TO ACCESS POINT/RELAY. 4. USE BAND-IT STRAPS TO FIX CO-AX CABLE CONDUIT TO OUTSIDE OF POLE. DISTRIBUTION CONSTRUCTION STANDARDS OPERATIONS STRUCTURE - STREET LIGHT POLE SSN NETWORK DEVICE WITH LV KIOSK (TYPE-1) SUPPLY ARRANGEMENT (ABOVE 100kM DISTANCE) REVISION DATE A DRAWING No. M1-6

8 NEW STREET LIGHT POLE OUTREACH JOINTING 1000 CO-AXIAL CABLE TOP OF BRACKET ANTENNAS (WAN & NAN) NOTE 1 20mm FLEXIBLE CONDUIT FOR MECHANICAL PROTECTION OF CABLES NOTE 4 ACCESS POINT/ RELAY L A N E N L N A N E A N E LV AC SUPPLY SEE NOTE 3 CIRCUIT BREAKER DETAIL KIOSK BATT MCB NOTE 2 (SEE DETAIL) ACCESS POINT CO-AXIAL CABLES SURGE PROTECTOR NOTES: USE 2 x 32mm BANDIT STRAPS FOR STREET LIGHTING POLES. 1PH CB WITH "NEUTRAL FEED THROUGH POLE". MTD IN KIOSK. EXTEND THE LV AC SUPPLY FROM LV UG CABLE TO CB IN LV KIOSK AND THEN TO ACCESS POINT/RELAY. DRILL A HOLE TO FIX 20mm RUBBER SEAL. LV UG SUPPLY 2.5mm 2C+E CABLE 0.6/1kV DISTRIBUTION CONSTRUCTION STANDARDS OPERATIONS STRUCTURE - STREET LIGHT POLE SSN NETWORK DEVICE WITH LV KIOSK (TYPE-1) SUPPLY ARRANGEMENT (ABOVE 100kM DISTANCE) REVISION DATE A DRAWING No. M1-7

9 SIDE VIEW OF P.T.S 7m 7m A OVERHEAD VIEW 7m A OVERHEAD VIEW SHOWS THE FOOTPRINT TO BE CLEARED STRUCTURE GROUND CLEARING REVISION DATE B AUG 2015 DISTRIBUTION CONSTRUCTION STANDARDS OPERATIONS POLE TOP SWITCH OR ISOLATOR GROUND CLEARING DETAILS DRAWING No. M3-1

10 CASE 1: THREE PHASE POLE D.O.F. X = DISTANCE FROM POLE TO OUTSIDE PHASE + 3m A 8m OUTSIDE PHASE Y X CASE 2: SINGLE PHASE POLE Y = 3m FROM CENTRE OF POLE A 8m A A 3m X D.O.F. POLE POLE NOTE: 1. POINT A SHALL BE DETERMINED BY FOLLOWING A LINE FROM THE FUSE TO THE GROUND ALONG THE ANGLE OF THE FUSE. 2. FOR THREE-PHASE POLES, POINT A SHALL BE DETERMINED FROM CENTRE PHASE. STRUCTURE - GROUND REVISION DATE B AUG 2015 DISTRIBUTION CONSTRUCTION STANDARDS OPERATIONS EXPULSION TYPE DROPOUT FUSE DRAWING No. M3-2 GROUND CLEARING DETAILS

11 9/03/ :30:03 AM pw:\\oca-pw-701.ghdnet.internal:pwv8iss4prodhp\documents\projects\61\31024 Drawing Management System Transition\08_0 DRAFTING\8_3 DRAWINGS\Drawings\M4-1.dgn GIS mleroux

12 9/03/ :33:52 AM pw:\\oca-pw-701.ghdnet.internal:pwv8iss4prodhp\documents\projects\61\31024 Drawing Management System Transition\08_0 DRAFTING\8_3 DRAWINGS\Drawings\M4-2.dgn GIS mleroux

13 9/03/ :38:02 AM pw:\\oca-pw-701.ghdnet.internal:pwv8iss4prodhp\documents\projects\61\31024 Drawing Management System Transition\08_0 DRAFTING\8_3 DRAWINGS\Drawings\M4-3.dgn GIS mleroux

14 0/03/2017 4:21:29 PM pw:\\oca-pw-701.ghdnet.internal:pwv8iss4prodhp\documents\projects\61\32028 Misc. Minor Support Works\08_0 DRAFTING\8_3 DRAWINGS\M4-4 GIS mleroux

15 COPYRIGHT AS/NZS 7000:2016

16 COPYRIGHT AS/NZS 7000:2016

17 COPYRIGHT AS/NZS 7000:2016

18 COPYRIGHT AS/NZS 7000:2016

19 COPYRIGHT AS/NZS 7000:2016

20 COPYRIGHT AS/NZS 7000:2016

21 COPYRIGHT AS/NZS 7000:2016

22 COPYRIGHT AS/NZS 7000:2016

23 COPYRIGHT AS/NZS 7000:2016

24 COPYRIGHT AS/NZS 7000:2016

25 COPYRIGHT AS/NZS 7000:2016

26 COPYRIGHT AS/NZS 7000:2016

Common Departures Interconnecting Facilities Requirements

Common Departures Interconnecting Facilities Requirements Welcome to our e-rew Express. In our last issue, we discussed the common departures on metering installation requirements. This time, we would like to discuss the common departures on the customer low

More information

UNDERGROUND CONSTRUCTION MANUAL SERVICES

UNDERGROUND CONSTRUCTION MANUAL SERVICES UNDERGROUND CONSTRUCTION MANUAL ack to MAIN INDEX Go to SECTION INDEX CONSTRUCTION DESCRIPTION DWG CONSTRUCTION DESCRIPTION DWG Construction code guide - Underground service from overhead system 53 SERVICE

More information

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket

More information

Network Asset Design Standard HV SUBSTATION FEEDER EXIT CIRCUITS ISOLATION POLICY

Network Asset Design Standard HV SUBSTATION FEEDER EXIT CIRCUITS ISOLATION POLICY Network Asset Design Standard HV SUBSTATION FEEDER EXIT CIRCUITS ISOLATION POLICY Original Issue: September 2007 Prepared by: Lee Chan & Rob Rogerson This Revision: 0 October 2007 Date For Next Review:

More information

PDI Modular Compact Remote Power Panel

PDI Modular Compact Remote Power Panel Guide Specifications (Revision 000, 6/17/2016) 1 GENERAL 1.1 Summary These specifications describe requirements for a remote power panel (RPP) distributing power to sensitive loads. These specifications

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1

Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1 Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1 Version 3.1: September 22, 2017. Please note that this Revision 3.1 may be subject to subsequent revisions.

More information

Water Corporation Electrical Preferred Equipment List

Water Corporation Electrical Preferred Equipment List Equipment other than that shown on this list may be used with the approval from the Water Corporation (Senior Principal Engineer, ME Asset Engineering) Equipment, whether specified below or not, shall

More information

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1993 Specifications CSJ s 0924-06-221,etc. & 0924-06-223 SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1. Description. This specification describes the minimum acceptable requirements for a weatherproof

More information

MTM DESIGN PRACTICE NOTE 110V AC SURGE PROTECTION IN SIGNAL EQUIPMENT ROOMS AND TRACKSIDE ZONE BOXES

MTM DESIGN PRACTICE NOTE 110V AC SURGE PROTECTION IN SIGNAL EQUIPMENT ROOMS AND TRACKSIDE ZONE BOXES SURGE PROTECTION IN SIGNAL Approval Amendment Record Approval Date Version Description 11/05/2016 1 Initial Issue under MTM PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

Three Phase Residential Solution for Australia, System Design and Installation Guidelines Three Phase Residential Solution for Australia, System Design and Installation Guidelines This document describes how to design and install SolarEdge three phase inverters for residential installations.

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016 Safegard V4 Panel Installation Datasheet ELECTROSTATIC SENSITIVE DEVICE This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product will directly

More information

POWER GRID AUTOMATION. Pág.. n. RMU Automation

POWER GRID AUTOMATION. Pág.. n. RMU Automation POWER GRID AUTOMATION RMU Automation Distribution Network Non-Controlled Secondary Distribution Systems Distribution Network RMU Automation - Levels RMU Automation - RTU / FRTU SMART CONTROLLER Monitoring

More information

Weathersafe Vision. Installation & Operating Instructions

Weathersafe Vision. Installation & Operating Instructions Weathersafe Vision Installation & Operating Instructions IP66 Products covered by these instructions 1 TGVL01 TGVL02 TGVL03 TGVL05 TGV101N TGV201N TGV104N Single Gang 2-Way Switch [SP] 10AX (Fluorescent

More information

Satellite INSTALLATION GUIDE

Satellite INSTALLATION GUIDE N3 Satellite INSTALLATION GUIDE ! WARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breaker or remove fuse. Damage to this product caused by wiring with power on voids

More information

EDS LV CUSTOMER UNMETERED SUPPLIES

EDS LV CUSTOMER UNMETERED SUPPLIES Document Number: EDS 08-2102 Network(s): Summary: ENGINEERING DESIGN STANDARD EDS 08-2102 LV CUSTOMER UNMETERED SUPPLIES EPN, LPN, SPN This standard details the requirements for unmetered single-phase

More information

VRp Three-Phase Precision AC Voltage Regulator

VRp Three-Phase Precision AC Voltage Regulator VRp-22500-0338 Three-Phase Precision AC Voltage Regulator INSTALLATION INSTRUCTIONS Inspection and Unpacking Please inspect the wooden crate for obvious shipping damage. Some crates contain up to six (6)

More information

EBB PILOT FOR THE LIVE CONNECTION OF UNMETERED EQUIPMENT TO OVERHEAD LINES

EBB PILOT FOR THE LIVE CONNECTION OF UNMETERED EQUIPMENT TO OVERHEAD LINES Network(s): Summary: ENGINEERING BULLETIN EBB 08-0061 PILOT FOR THE LIVE CONNECTION OF UNMETERED EQUIPMENT TO OVERHEAD LINES EPN, SPN This bulletin provides a framework for the pilot scheme for unmetered

More information

ELECTRICAL SAFETY INSPECTION REPORT

ELECTRICAL SAFETY INSPECTION REPORT ELECTRICAL SAFETY INSPECTION REPORT CHITTAGONG FASHION WEAR LTD. SOUTH HALISHAHAR, CHITTAGONG, BANGLADESH Factory List: 1. Chittagong Fashion Wear Ltd. 2. H & W Apparels Inspected on May 5, 2014 SUMMARY

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 TABLE OF

More information

SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station

SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station SPI PowerNet Reference: ZD23 Version: 1.1 Issue date: 15 May 2014 Contents 1 Scope... 3 2 Deer Park Terminal

More information

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series Installation Manual APEX Series Silicon and MOV Panel Protection APEX Series APEX Series Installation Guide 2 Table of Contents Mechanical Installation 3 Table One - Application Rating 3 Figure 1 - Mounting

More information

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering

More information

INSTALL INSTRUCTIONS RSXMR-9886-P-48

INSTALL INSTRUCTIONS RSXMR-9886-P-48 INSTALL INSTRUCTIONS RSXMR-9886-P-48 Installation Instructions RSXMR-9886-P-48 (CEQ. 20194) INSTALL INSTRUCTIONS RSXMR-9886-P-48 Contents Section Description Page 1 Copyright 2 1.1 Disclaimer 2 1.2 Warnings

More information

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority From Design to Installation, Appleton is The Switchrack Authority With over 80 years in the industry, Appleton is one of the first and the most respected names in custom switchracks for hazardous and adverse

More information

one cool inverter. GT Series Solar Inverter Quick Install Guide v1.4

one cool inverter. GT Series Solar Inverter Quick Install Guide v1.4 one cool inverter. GT Series Solar Inverter Quick Install Guide v1.4 This quick installation guide must be used in conjunction with the Installation Manual. For installation support contact your local

More information

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE www.osram-americas.com S90655 OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE OSRAM ReliaSys TM Outdoor LED Retrofit Kit is an alternative to high-intensity discharge (HID) lamps up to 400W (MH)

More information

Electrical Specifications

Electrical Specifications Electrical Specifications Input Voltage Input Power Input Frequency 87-240V AC 65W Maximum (20W Typical) 47-63 Hz Material Specifications Main unit: Anodised Aluminium End plates: UL V-0 rated polycarbonate

More information

CONTROL PANEL WIRING SPECIFICATIONS

CONTROL PANEL WIRING SPECIFICATIONS CONTROL PANEL WIRING ISSUE STATUS FIRST REV DESCRIPTION DATE 001 1 ST ISSUE 22/04/2014 002 1 ST AMMENDMENT 10/03/2017 003 2 ND AMMENDMENT 08/09/2017 THIS DOCUMENT IS DESIGNED TO COVER ALL APPLICATIONS,

More information

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007 RE-82 RACK MOUNT DIMMER 8 X 2400Watts OWNERS MANUAL Revision 2.4 11/29/2007 Page 2 of 8 RE-82 CONTROL PANEL DESCRIPTION The RE-82 is an 8 channel dimmer with a maximum capacity of 2,400 watts per channel

More information

The JODEL Piglet System Installer s Manual

The JODEL Piglet System Installer s Manual The JODEL Piglet System Installer s Manual O Donnell Enterprises Ltd Tierlahood, Stradone, Co Cavan, Ireland Phone 00353 (0)49 4330088 Fax 00353 (0)49 4330200 Mobile 00353 (0)86 2597617 E mail jodelpad@eircomnet

More information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check

More information

Panel Installation Datasheet

Panel Installation Datasheet ACTIONPAC LNS5 & SAFEGARD V5 Panel Installation Datasheet ELECTROSTATIC SENSITIVE DEVICE This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

SLI 15 INVERTER SERIES, 1500 W

SLI 15 INVERTER SERIES, 1500 W SLI 15 INVERTER SERIES, 1500 W FEATURES DESCRIPTION New, compact design: 1U height x 19" width x 14.94" depth; 19" rack-mountable High efficiency: up to 93% True sine wave output Parallelable output with

More information

Certificate of Conformity

Certificate of Conformity Applicant: Electrical Apparatus: Type of Protection: Marking Code: Manufacturer: Manufacturing Location: Seamless Mining Products Pty Ltd Unit 3/29 Mustang Drive Rutherford NSW 2320 11 kv 800 A Type A

More information

Recording and Reporting of High Voltage and Low Voltage Switching

Recording and Reporting of High Voltage and Low Voltage Switching 1 SCOPE This document details the procedures to be adopted prior to, during, and on completion of Switching operations, and details the manner in which HV and LV Switching shall be recorded in order to

More information

Slimline LED Floodlight

Slimline LED Floodlight Slimline LED Floodlight Model: LEDPRO10WH (White) Model: LEDPRO10B (Black) Model: LEDPRO30WH (White) Model: LEDPRO30B (Black) Model: LEDPRO20WH (White) Model: LEDPRO20B (Black) Model: LEDPRO50WH (White)

More information

ECP NORTROLL CABLETROLL 2350 FPI INSTALLATION AND COMMISSIONING PROCEDURE

ECP NORTROLL CABLETROLL 2350 FPI INSTALLATION AND COMMISSIONING PROCEDURE Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE ECP 11-0521 NORTROLL CABLETROLL 2350 FPI INSTALLATION AND COMMISSIONING PROCEDURE EPN, LPN, SPN This document details the installation, testing

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

Installation Instructions & User Manual

Installation Instructions & User Manual Installation Instructions & User Manual ZONEMASTER PRO AC Panel Transient Voltage Surge Suppressors The Wiremold Company In US: 60 Woodlawn Street, West Hartford, CT 06110 800-621-0049 FAX 860-232-2062

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.

More information

TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS)

TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS) Issue 11 Page 1 of 5 Model Selection Guide Instructions Consult Steps to Selecting Appropriate Conductivity Instrumentation and Cells before making selections below. Select the desired key number. The

More information

B60 Domestic Voltage Optimisation Unit

B60 Domestic Voltage Optimisation Unit B60 Domestic Voltage Optimisation Unit Installation Manual V1.2 Nov 2013 1 P a g e PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with the IEE Wiring Regulations,

More information

TP&N DISTRIBUTION BOARD TYPE B RANGE

TP&N DISTRIBUTION BOARD TYPE B RANGE GROUP Now included in the range: Extension Boxes Metering Kits Surge Suppression and more! TP&N DISTRIBUTION BOARD TYPE B RANGE A comprehensive distribution board range for modern commercial & industrial

More information

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM 1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL

More information

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide For use with 9PX 5000/6000/8000/11000 VA UPS Models FCC Part 15 Class A EMC Statements

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

Release Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location

Release Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location First Published: 2017-01-31 Text Part Number: Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series Prerequisites This document uses illustrations to explain the workflow that we recommend

More information

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL AC Panel Transient Voltage Surge Suppressors INTRODUCTION This document explains how to install the Powerware TVSS ZoneSentinel AC Panel

More information

Ruckus Wireless ZoneFlex 7782 Dual Band n Outdoor Access Point. Installation Guide

Ruckus Wireless ZoneFlex 7782 Dual Band n Outdoor Access Point. Installation Guide Ruckus Wireless ZoneFlex 7782 Dual Band 802.11n Outdoor Access Point Installation Guide Part Number 800-70387-001 Rev 01 Published July 2012 www.ruckuswireless.com Contents 1 About this Installation Guide.................................................

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

New 30AA and 31AA Electronic Motor Protection Modules. Application Bulletin 128

New 30AA and 31AA Electronic Motor Protection Modules. Application Bulletin 128 New 30AA and 31AA Electronic Motor Protection Modules Application Bulletin 128 Application Bulletin Number: 128 Release EN: D09910 Date: 4/19/96 Revision EN: Z27301 Date: 10/2/15 Subject: New 30AA and

More information

UNPRICED BID Tender no: INF/ISRF/ELE/91/2018 Name of work : INSTALLATION OF CCTV CAMERAS FOR ISRF PROJECT SITE SL NO DESCRIPTION OF WORK UNIT QTY (A) UNIT RATE SUPPLY (Rs.) Basic Supply Rate/Unit Including

More information

ORB TM 4-20 ma Input Box Installation & Operation Manual

ORB TM 4-20 ma Input Box Installation & Operation Manual IOM ORB TM 4-20 ma Input Box Installation & Operation Manual ORB TM 4-20 ma Input Box Installation & Operation Manual CONTENTS I. HANDLING & STORAGE... 1 Inspection and Handling Disposal and Recycling

More information

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:

More information

Chameleon Stand-alone

Chameleon Stand-alone Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools

More information

Data Manager Installation Guide

Data Manager Installation Guide PR05XX Data Manager Installation Guide Resource Data Management Ltd 80 Johnstone Avenue, Hillington Industrial Estate, Glasgow, Scotland G52 4NZ UK +44(0)141 810 2828 Switchboard support@resourcedm.com

More information

Model 7416LED

Model 7416LED INSTALLATION INSTRUCTIONS FOR Model 7416LED www.sportablescoreboards.com 1 Table of Contents DESCRIPTION... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR REPORTING SHIPPING

More information

Make the Switch. Your Specialist in CONTROL SOLUTIONS SPEEDY BUILD. AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (20A A)

Make the Switch. Your Specialist in CONTROL SOLUTIONS SPEEDY BUILD. AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (20A A) Make the Switch SPEEDY BUILD Rapid Run Service AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (0A - 150A) Your Specialist in CONTROL SOLUTIONS Contents 3. Surface Mounting IP65 Plastic

More information

ELPROMA NTSprotect Surge Protection

ELPROMA NTSprotect Surge Protection ELPROMA NTSprotect Surge Protection Rack 19 back panel with NTS-protect As the antenna is roof mounted (to have a clear view of the sky) it is likely to be exposed to lightning strikes. Protection against

More information

Sollatek SVS Range Voltage Stabilisers User Manual

Sollatek SVS Range Voltage Stabilisers User Manual CONTENTS Subject Page(s) Sollatek SVS Range Voltage Stabilisers User Manual SAFETY Safety 2 Main SVS Features 3 SVS Specification 4-5 Unpacking 6 Inspection 6 Installation 6-9 Operation 10-11 Troubleshooting

More information

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs) Models beginning with 2M, 2L or 2X Series 2000 Multiple Meter Units (MMUs) Product Description Technical Specifications Installation Instructions February 28 th, 2013 List of Figures...2 List of Tables...2

More information

Instruction Manual. Contents

Instruction Manual. Contents SceneSelect II Scene-setting and Dimming System SBD410 HF BALLAST CONTROLLER Instruction Manual Warning... 2 Features... 2 Important Safeguards... 2 Internal View......3 Mounting... 4 Supply & Load Cable

More information

Installation and Hardware Guide

Installation and Hardware Guide Helios W.E.S. 1000 & 2000 (Wireless Emergency Stop) Installation and Hardware Guide E5, Version 1.3 Helios Global Tech Ltd. Contact Information Helios Global Technologies 1920 Windsor Rd Kelowna BC V1Y

More information

Conveyor Belt Alignment Switches from IDEM

Conveyor Belt Alignment Switches from IDEM Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are

More information

Installation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet

Installation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet S&C IntelliCap Automatic Capacitor Control Installation Table of Contents Section Page Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet...

More information

SECTION SWITCHGEAR

SECTION SWITCHGEAR SECTION 26 23 13 SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

EOS SCHNEIDER RINGMASTER 'C' RANGE SWITCHGEAR

EOS SCHNEIDER RINGMASTER 'C' RANGE SWITCHGEAR Document Number: EOS 03-0018 Network(s): Summary: ENGINEERING OPERATION STANDARD EOS 03-0018 SCHNEIDER RINGMASTER 'C' RANGE SWITCHGEAR EPN, LPN, SPN This standard details the installation, commissioning

More information

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller HydroGuard 4 to 20 ma Output Module For use with HydroGuard Water Quality Monitor and Controller Technician's Manual Installation, Operation, and Maintenance Guide Chapter 1: Preface... 3 1.1 Intended

More information

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding AU1-10R AU1-10P FR1-R EU1-P Cat. No. Drawing Configuration Australian GFCI (RCD) angle plug. trip. 10 ampere 230 volt, 50 Hz. 20 watt maximum. Test

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The

More information

MODELS PD230 AND PD1230 Installation Instructions

MODELS PD230 AND PD1230 Installation Instructions PNEUMERCATOR Liquid Level Control Systems MODELS PD20 AND PD20 Installation Instructions Model PD20 x2 Channel Lightning Surge Protector Model PD20 x2 Channel Lightning Surge Protector COPYRIGHT 2007 PNEUMERCATOR

More information

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module Han termination Contents Page Han-Fast Lock... 20.11 adapter for Han DD... 20.13 adapter for Han DDD module... 20.16 adapter for Han 40 A Axial module... 20.18 adapter for Han E... 20.20 adapter for Han

More information

Panduit Basic Rack PDU

Panduit Basic Rack PDU Panduit Basic Rack PDU User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any

More information

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Course Details Date: January 28 January 31, 2019 Time: 8:00 A.M. - 4:30 P.M. Capacity: 12 attendees Provider: National Technology

More information

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Series Amp Pad Mount Quick Connect Input and Output Power Panels Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.

More information

PV-MOLD Nonmetallic Pole Riser System

PV-MOLD Nonmetallic Pole Riser System PV-MOLD Nonmetallic Pole Riser System Standard Duty Heavy Duty Schedule 40 Extra Heavy Duty Schedule 80 Vented Boots Adapters Couplings Backing Plates 23240 C hagrin Bl vd Suite 405 Cleveland, OH 44122

More information

Specifications, Installation, and Operating Instructions

Specifications, Installation, and Operating Instructions Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.

More information

6 Check that the earth system is complete, undamaged and bonded to earth points ( including capacitor and control).

6 Check that the earth system is complete, undamaged and bonded to earth points ( including capacitor and control). NOTE: SAFETY: Tests must be carried out after the installation, alteration or repair and before putting back to service. At all times maintain suitable clearance to all other electrical equipment and verify

More information

Surge Protective Device

Surge Protective Device SURGE PROTECTIVE DEVICE Surge Protective Device 20 R 320 Type Max. discharge current Imax/Iimp (ka) Number of poles (P) R: with alarm auxiliary contact Blank: without alarm auxiliary contact Max. continuous

More information

PRO REMOTE 25 LV CAPACITANCE PROBE

PRO REMOTE 25 LV CAPACITANCE PROBE Price $5.00 PRO REMOTE 25 LV CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS GENERAL SPECIFICATIONS...3 1.0 INTRODUCTION...4 2.0 APPLICATIONS...4

More information

Manual: Distribution Substation Manual (DSM) Section 1: Customer Supply Arrangements

Manual: Distribution Substation Manual (DSM) Section 1: Customer Supply Arrangements Manual: Distribution Substation Manual (DSM) Section 1: Customer Supply Arrangements Standard Number: HPC-5DA-07-0001-2012 Document Control Author Name: Viswa Easwaran Position: Standards Engineer Document

More information

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template.

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template. 6. ENGINEERING SYSTEMS REQUIREMENTS G40 SITE ELECTRICAL UTILITIES SYSTEMS REQUIREMENTS SITE ELECTRICAL UTILITIES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT

More information

TSR A & B - FACILITIES STUDY REPORT

TSR A & B - FACILITIES STUDY REPORT TSR-11-0502A & B - FACILITIES STUDY REPORT Transmission Service Request No. TSR-11-0502A&B 2 x 25 MW Wind Energy Generating Facilities From POI on Gladstone Walsenburg 230 kv Line to Ojo Substation 345

More information

MAINS DISTRIBUTION UNIT MDU14-CO

MAINS DISTRIBUTION UNIT MDU14-CO MAINS DISTRIBUTION UNIT MDU14-CO Dual Input Auto Changeover 14 Output Mains Distribution Unit. Handbook Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200,

More information

FORM FOR PROPOSAL FOR 2014 NATIONAL ELECTRICAL CODE

FORM FOR PROPOSAL FOR 2014 NATIONAL ELECTRICAL CODE FORM FOR PROPOSAL FOR 2014 NATIONAL ELECTRICAL CODE INSTRUCTIONS PLEASE READ CAREFULLY Type or print legibly in black ink. Use a separate copy for each proposal. Limit each proposal to a SINGLE section.

More information

IMP/ 001 / 014 Policy for the Protection of Distribution Networks

IMP/ 001 / 014 Policy for the Protection of Distribution Networks Version:- 1.1 Date of Issue:- July 2016 Page 1 of 39 IMP/ 001 / 014 Policy for the Protection of Distribution Networks 1. Purpose The purpose of this document is to detail the network protection philosophy

More information

AIDON PRODUCT CATALOG

AIDON PRODUCT CATALOG AIDON PRODUCT CATALOG Available Customer Products Version 4.3 A Copyright 2014 Aidon Ltd. Aidon Oy Piippukatu 11, FI-40100 JYVÄSKYLÄ, Finland +358 207 205 880 www.aidon.com AIDON PRODUCT CATALOG 2 (8)

More information

Best Practices Guide. EMC VMAX3 Family. Best Practices Guide for AC Power Connections REVISION 2.0. August, 2015

Best Practices Guide. EMC VMAX3 Family. Best Practices Guide for AC Power Connections REVISION 2.0. August, 2015 Best Practices Guide EMC VMAX3 Family Best Practices Guide for AC Power Connections REVISION 2.0 August, 2015 Best practices overview for AC power connections... 3 Selecting the proper AC power connection

More information

B60 Domestic Voltage Optimisation Unit. Installation Manual

B60 Domestic Voltage Optimisation Unit. Installation Manual Govna B60PVM Voltage Optimisation Unit Govna B60PVM Voltage Optimisation Unit B60 Domestic Voltage Optimisation Unit Web: www.renewableenergyhub.co.uk Email: info@renewableenergyhub.co.uk Phone: 0845 862

More information

US Catalog July 2016 SMISSLINE TP

US Catalog July 2016 SMISSLINE TP US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information

More information

CREATING & CUSTOMIZING SUBYPES & DOMAINS FOR YOUR GIS. Robert Borchert GIS Technician II Great River Energy

CREATING & CUSTOMIZING SUBYPES & DOMAINS FOR YOUR GIS. Robert Borchert GIS Technician II Great River Energy CREATING & CUSTOMIZING SUBYPES & DOMAINS FOR YOUR GIS Robert Borchert GIS Technician II Great River Energy What do you do for a living What do you do for a living? I am a GIS Technician. Oh! What does

More information

2 Check that Public Safety has been considered (e.g. cabinet secured and locked, trip hazards removed where applicable).

2 Check that Public Safety has been considered (e.g. cabinet secured and locked, trip hazards removed where applicable). NOTE: SAFETY: Tests must be carried out after the installation, alteration or repair and before putting back to service. At all times maintain suitable clearance to all other electrical equipment and verify

More information