Instruction manual. Ensite Pro Configuration Tool

Size: px
Start display at page:

Download "Instruction manual. Ensite Pro Configuration Tool"

Transcription

1 Instruction manual Ensite Pro Configuration Tool

2 Copyright Enraf B.V. All rights reserved. Reproduction in any form without the prior consent of Enraf B.V. is not allowed. This instruction manual is for information only. The contents, descriptions and specifications are subject to change without notice. Enraf B.V. accepts no responsibility for any errors that may appear in this instruction manual. The warranty terms and conditions for Honeywell Enraf products applicable in the country of purchase are available from your supplier. Please retain them with your proof of purchase.

3 Preface This manual describes how to work with the configuration tool Ensite Pro. It has been written for the technicians involved in the commissioning and service of the series 880 CIU Prime and Plus. Safety and prevention of damage Cautions and Notes have been used throughout this manual to bring special matters to the immediate attention of the reader. A Caution draws attention to an action which may damage (the operation of) the equipment. A Note points out a statement deserving more emphasis than the general text. Additional information Please do not hesitate to contact Honeywell Enraf or its representative if you require additional information. Legal aspects The information in this instruction manual is copyright property of Honeywell Enraf B.V., Netherlands. Enraf B.V. disclaims any responsibility for personal injury or damage to equipment caused by: Deviation from any of the prescribed procedures Execution of activities that are not prescribed Part No.: Revision 4 Ensite Pro Configuration Tool 3

4 Table of Contents Preface Table of contents Introduction Ensite Pro configuration tool - General Configuration Procedure Procedure steps Preparation Retrieving configuration data of gauges Configuration of the Tanks Configuration of CIU Primes Configuration of CIU Pluses Linking Gauges, Tanks and CIU s Downloading configuration data Start Ensite Pro Select site Global settings Configure data inputs Gauge Level Water Temperature Density Pressure Vapour Scan Tank Configure tanks Tank Product Vapour Shell Flow Roof TCT Links Ensite Pro Configuration Tool Part No.: Revision 4

5 Table of Contents Configure CIU Prime HostPort HostPort Hot standby FieldPorts Tambient Configure CIU Plus HostPorts Hot standby FieldPort 1 & Communication setup Configure links Data inputs Tanks CIU Prime Download configuration Upload configuration Service note(s) Set date and time Print configuration Show diagnostic data Tank viewer Scan viewer Help User privileges Stop Ensite Pro Appendix A: related documents Part No.: Revision 4 Ensite Pro Configuration Tool 5

6 Introduction The configuration of the Honeywell Enraf Entis system consists of the modular parts: Entis Pro CIU Plus CIU Prime field instrumentation Entis Pro CIU Plus CIU Prime Field instrumentation Ensite Pro - Commissioning - Diagnostics - Documentation This system displays calculated data from the CIU Plus. It is a Windows NT based program, displaying data in windows, boxes, tables, graphs, etc. This unit calculates volume and mass. It requests input data from the CIU Prime and calculates all other data. It presents data to higher layered systems like Entis Pro, SCADA, DCS, ENSITE, etc. This unit is an interface between the field instrumentation (e.g. 854 ATG, 873 SmartRadar, etc.) and inventory systems (CIU Plus, PLC, ENSITE, etc.). The instruments in the field collect data such as level, temperature, density and/or pressure. The instruments are based on several principles: mechanical, servo, radar, hydrostatic and capacitive or a combination. The instruments measure the data and transmit it upon request of higher layered systems. Ensite Pro is a configuration tool for commissioning, diagnostics and documentation of the above mentioned modules CIU Prime / Plus (880 series) and Entis Pro. Some information will be asked to fill in, needed to program the CIU Prime / Plus. Ensite Pro automatically puts the input on the right (default) positions. The build in diagnostic data views, reads and writes data direct from and to the CIU Prime / Plus. The whole configuration can be printed to have a hard back-up. See later in this manual. 6 Ensite Pro Configuration Tool Part No.: Revision 4

7 Ensite Pro configuration tool General The configuration tool works with windows. Within these windows are buttons, on which the function is written. One of the characters on a button is underlined. Throughout the configuration tool, common buttons are used. Their description is given once: Press the Ok -button to save the changed parameters in the site database and terminate the dialog. Press the Cancel -button to ignore any changes made. The program returns to the previous window. In some cases this button has been renamed into Close. To indicate that a value is modified the background colour of input boxes, drop down boxes, checkboxes and radio buttons get yellow once the contents is changed. Pressing cancel restores the values of the modified fields which have a yellow background. The values to restore are the values retrieved from the database at opening or the last applied. If the new value is accepted by pressing Apply or OK the new values get stored in the database and the background returns to the default colour. Press the Apply -button to save the changed parameters in the site database and work with it accordingly, but remain in the active window. All fields with a yellow background colours back to the default background colour. Press the Advanced -button or check the embedded checkbox to activate the advanced part in the active window. Activate functions The function of a button can be activated in several ways: - mouse move the mouse pointer to the button and click the left mouse button - Alt -key press the Alt -key simultaneously with the underlined character key of the text on the button. - Tab -key press the Tab -key to scroll over all buttons. When the desired button is reached (marked), press the Enter -key. Part No.: Revision 4 Ensite Pro Configuration Tool 7

8 Configuration Procedure This chapter describes the general configuration procedure for the 880 CIU Prime, CIU Plus. For programming the 880 series CIU s, it is necessary to use Ensite Pro. It is programmable to communicate via one of the higher levels, i.e. via a CIU Plus to a CIU Prime, or even via Entis Pro to any of the connected CIU s. Procedure steps The complete configuration procedure consists out of the following steps: Preparation Retrieving configuration data of gauges. Configuration of Tanks Configuration of the CIU Prime(s) Configuration of CIU Plus( s) Linking Gauges, Tanks and CIU s Preparation Before you start configuring 880 series CIU and possible one or more Entis Pro stations, certain preparations are necessary. Be sure that the following information is available: Site layout Field cabling information (which gauges are connected on the same pair of field wires, etc.) Tag names of field devices (gauges, CIU and tanks) Tank information (strapping tables, or tank capacity tables, roof details, etc.) Information on the types of stored product Host communication setup (if applicable, i.e. Modbus memory maps, etc.) Modems and possible other communication hardware connected to the CIU s 8 Ensite Pro Configuration Tool Part No.: Revision 4

9 Configuration Procedure The first step in Ensite Pro is the creation of a site. This allows the program to store multiple configuration sets, with each a separate database. After a new site has been created, the program will prompt for a set of global settings. These settings are required for initiating the configuration database. Once the global settings are entered, Ensite Pro will create a site database. If there is a.log file available for this gauge it can be extracted by Ensite Pro. The data extraction pre-sets all the relevant configuration parameters. The next step is the creation off all tanks. Retrieving configuration data of gauges As first step the gauges should be configured correctly. This can best be done by means of the DOS program ENSITE or its successor Engauge. With ENSITE the so called.log files can be created. These.LOG files contain all the programmable settings of relevant gauge. If no gauges are installed yet, it is also possible to prepare these in ENSITE. They can then later be down loaded into the gauge. Configuration of the Tanks Also the creation of the tanks is a straightforward process. At the creation of a new tank, the user is always prompted for a name. Preferably use the same name as the name already in use on site. Once the tank has been created, the user has to enter specific tank details, like Tank shape, Roof details, etc. Tank strapping tables or capacity tables can be linked via an external file. This file needs to be in the format of the TCT specification. The format of this file can be found in the Instruction manual series 880 CIU Plus. The straps can either be manually entered, or be calculated out of a formula, depending on what information is available. The strapping file can contain a maximum of 2000 straps. The total capacity of the CIU+ is straps. The data can best be prepared by means of a spreadsheet program like Excel or Lotus 123. Users already using Entis+, can contact the factory for a TCT extraction program. This program extracts the strapping table out of the internal Entis+ database, and converts it into an Ensite Pro compatible format. Once all the tanks are created in the database, the user can either start with the configuration of the CIU Primes or the CIU Pluses. Part No.: Revision 4 Ensite Pro Configuration Tool 9

10 Configuration Procedure Configuration of CIU Primes In the 880 series CIU Prime, the following parts can be configured: HostPort 1 HostPort 2 Hot standby (if applicable) Field ports (1 through 4) The hot standby settings are required if redundant CIU Primes are installed. The Field ports settings depend on the type of the installed interface cards in the CIU Prime. The host port settings are required to make the CIU Prime compatible with the connected hardware and software, i.e. the CIU Plus or a PLC. Refer to chapter Modbus settings in this manual. Configuration of CIU Pluses In the 880 series CIU Plus, the following parts can be configured: Hostports (1 through 4) Hot standby (if applicable) FieldPort 1 FieldPort 2 The hot standby settings are required if redundant CIU Primes and/or CIU Pluses are installed. The host port settings are required to make the CIU Plus compatible with the connected hardware and software, i.e. a PLC, Entis Pro or a DCS system. Refer to chapter Modbus settings in this manual. The FieldPort settings inform the CIU Plus about the communication setting to one or more CIU Primes. Linking Gauges, Tanks and CIUs After all the data inputs, Tanks, CIU Primes and CIU Pluses are configured the linking of all devices can commence. On basis of the actual or planned installation, the user has now to link the hardware: The data inputs to the tanks, The tanks to the CIU Primes, The CIU Primes to the CIU Pluses. Refer to the chapter Configure link in this manual. 10 Ensite Pro Configuration Tool Part No.: Revision 4

11 Configuration Procedure Downloading configuration data Once you have verified all the settings of all the devices, you can download the configuration database into the respective CIUs. The first time it is advised to do downloading directly on the targeted CIU (Prime of Plus). Ensite Pro offers this downloading as a standard feature, even over modem lines. Later modifications on the CIU configuration can also be done via a CIU Plus into a CIU Prime or even via Entis Pro from any of the network stations. Always make a backup of the site database before making any modifications. This can done as follows: Use the Window explorer and locate the root directory of the site (C:\ Documents and Settings\All Users\Application Data\Enraf\SiteDatabase\ Ensite Pro\[Site Name]). Make a copy of this folder to another location preferred on another device like a USB disk. Part No.: Revision 4 Ensite Pro Configuration Tool 11

12 Start Ensite Pro Ensite Pro is designed for Windows XP and can be started in the following way: Press the Start -button Select All Programs Select Enraf Select Configuration Activate Ensite Pro -shortcut The splash screen is shown, followed by the login window: Ensite Pro splash Ensite Pro login 12 Ensite Pro Configuration Tool Part No.: Revision 4

13 Start Ensite Pro When the correct password is given (the Administrators default password is Ensite Pro ), the program starts up with the following toolbar: While no site is selected yet only four buttons of the Ensite Pro toolbar are illuminated: Select Site A site gives an overview of the configuration at a specific customer s site. Selecting a site gives you access to a database. User privileges Access parameters for different users can be set or selected. A site must be created to be able to work with the configuration tool. Press the upper left button to illuminate all other buttons. Help The build in help document assists at any time. Pressing this button pops up the electronic version of this manual. About The screen which pops up after pressing this button shows version information of the Entity definition database and the selected site database. Part No.: Revision 4 Ensite Pro Configuration Tool 13

14 Select site A site gives an overview of the configuration at a specific customer s site. Selected sites are highlighted. Press this button to copy the highlighted site from the list. Only specific data must be changed afterwards. When the site is not in the list (yet), a new site has to be created. Press the New -button to add a site: Press the Ok -button to let the new site appear in the list box. Press this button to select the highlighted site to work with. You can also double click on the highlighted site name. Press this button to import an earlier made site database. Press this button to remove the highlighted site database from the list. After deleting the database from the folder the application will ask you to remove the strap-, ini- and Log files with their according sub folders. 14 Ensite Pro Configuration Tool Part No.: Revision 4

15 Global settings This window automatically pops up after a site has been created. In this window, global settings for the selected site can be programmed. These global settings cover the way data is represented. Data in the fields Dimensions and Text can only be changed/set after a new site has been created, all other data can also be changed/set at a later stage. Level and volume engineering units entered must be consistent with the dimensions of the tank strap tables intend to use. Global settings Dimensions - Level Select m, mm, ft, in, in/16, fis or 1/256 in. - Temperature Select C or F - Density Select kg/m 3, API, lbs/ft 3, dens60/60 or lbs/us gal. - Pressure Select kgf/cm 2, Pa, kpa or psi (lbf/in 2 ). - Flow Select m 3 /min, m 3 /h, l/min, l/h bbls/min, bbls/h, US gal/min, Us gal/h or UK gal/h. - Volume Select l, m 3, US gal or bbls. - Mass Select kg, metric ton, US ton, lbs or long ton. Std. ambient Enter ambient air pressure in kpa (default = kpa). air pressure Air density Enter air density in kg/m 3 (default = kg/m 3 ). Part No.: Revision 4 Ensite Pro Configuration Tool 15

16 Global settings After all global settings are made, the program warns the user that it is not possible to change the settings anymore. When confirmed, the program displays the following window: The following buttons are now available: Site Select site. A site gives an overview of the configuration at a specific customers site Global settings. Global settings cover the way data is represented, as well as some local figures. These settings are valid for the particular site only. Configure Enraf Equipment Configure data inputs. The data inputs collect data such as level, temperature, density and/or pressure. Configure tanks. A tank is a (large) container to store liquids or gases. Configure CIU Prime. The CIU Prime is an interface between the field instrumentation and inventory systems. To setup the CIU Prime, the port configuration must be programmed. Configure CIU Plus. The CIU Plus calculates volume, standard volume, mass, density, flow rate etc. To setup the CIU Plus, the port configuration must be programmed. Communication setup. To be able to communicate with the CIU Plus and Prime the communication parameters of the PC serial port must be set. Configure links. After all individual components (CIU Prime, CIU Plus, tanks and data inputs) have been configured, they have to be linked to each other. 16 Ensite Pro Configuration Tool Part No.: Revision 4

17 Global settings Distribute Download configuration. The (new) programmed configuration must be downloaded for the CIU Prime / Plus to work with. Upload configuration. The upload function is disabled in the toolbar by default. Utilities Tank viewer. All measured and calculated data from one tank can be viewed. Scan viewer. The field scan can be viewed. Show diagnostic data. The build in diagnostic data views, reads and writes data direct from and to the CIU Prime / Plus. Set date and time. The current date and time of the CIU Prime / Plus, can be (re-)set. Reports Program Service note(s). The build in text editor gives the possibility to store information about the current site. Print configuration. The whole configuration can be printed to have a hard copy. User privileges. Access parameters for different users must be set. Help The build in help document assists at any time. Pressing this button pops up the electronic version of this manual. About The dialog, which will pop-up by pressing this button shows the version number of the application, Entity definition database and site database. Part No.: Revision 4 Ensite Pro Configuration Tool 17

18 Configure data inputs The data inputs (Honeywell Enraf field instruments) collect data such as level, temperature, density and/or pressure. The instruments measure the data and transmit it upon request of higher layered systems. Press the Copy -button to copy the highlighted data input from the list. Only specific data must be changed afterwards. When the data input is not in the list (yet), a new data input has to be created. Press the New -button to add a data input: Press the Edit -button to edit data from the highlighted data input: - Gauge - Water - Density - Vapour - Level - Temperature - Pressure - Scan Press the Delete -button to remove the highlighted data input from the list. If the data input is linked to a Tank this data input cannot be deleted. 18 Ensite Pro Configuration Tool Part No.: Revision 4

19 Configure Data Inputs Data Input - Gauge Gauge LOG file Press the Browse -button to select an Ensite gauge log file (if available). Press the Extract -button to fill in the data from the gauge log file in the next tabs A warning is generated before a log file is extracted while settings have been entered already. All engineering units in a gauge log file must be compatible with the system engineering units as defined for the global dimensions. Gauge - Gauge type Select Unknown, 802, 811, 812, 854, 866, 872, 873, 877, 894, 970, 971, 973 or Gauge details Select h for 854 gauges using the ZLQ record (up to software version SPUA1.0) or select - for 854 gauges (with software version SPUA2.0 onwards). Allowed gauge commands - Test gauge Check if allowed (TG; 811, 854, 894 only). - Block gauge Check if allowed (BL; 811, 854, 894 only). - Tank profile Check if allowed (TP; 854, 894 only). - Gauge alarm test Check if allowed (AT; 873 only). - Lock test Check if allowed (LT; 811, 854, 894 only). - Water dip Check if allowed (I3; 811, 854, 894 only). - Interface profile Check if allowed (IP; 854, 894 only). Part No.: Revision 4 Ensite Pro Configuration Tool 19

20 Configure Data Inputs - Verify command Check if allowed (CA; 854, 894 only). - Reset gauge Check if allowed (RS). - Interface 2 command Check if allowed (I2; 854, 894 only). General limits: All instruments from one tank must be connected to the same FieldPort. Using BPM cards: Up to 50 data inputs can be equally divided over the four FieldPorts of the CIU Prime, with a maximum of 15 data inputs per line. The instrument address on each port is free selectable between The instrument address must be unique for all data inputs on the same CIU. Using RS232/485 cards: Field addresses may contain 3 digit address numbers. Data Input - Level Level enabled Check to enable level scan mm Check to enable. This selection is only possible if the level level resolution engineering unit is set to m or mm and if the gauge type is not 811, 813, 866 or Negative Check to enable. This selection is only possible for gauge levels enabled types 854, 872, 873 and 894 No alarm when gauge in test Level killed Check to disable gauge alarms during operational commands. Check to disable level scan. 20 Ensite Pro Configuration Tool Part No.: Revision 4

21 Configure Data Inputs - Manual overwrite Enter manual product level. Only available if level enabled is checked. Advanced settings The Advanced settings below get enabled if the advanced button is pressed or the embedded checkbox is checked. - Level address Enter level transmission address. - Level TOI Select: A, B, C, E or M*. - Level TOR Select: B, J, L, M or ZLQ (the combination of level TOR ZLQ and level type Ullage is not possible. With level type Ullage, use level TOR L )*. * refer to Table 1 on page 26 for additional information. Data Input - Water Water probe enabled Check to enable water level scan from external probe. Water dipping enabled Check to enable water level scan from servo gauge. - Offset Enter water level offset. - Min. water level Enter minimum water level. This value is used when no water level is found. Manual overwrite Enter manual water level. Only possible if water probe or dip is enabled. Advanced settings The Advanced settings below get enabled if the advanced button is pressed or the embedded checkbox is checked. - Water address Enter water level transmission address. - Water TOI Select: A, B, C, E or M*. Part No.: Revision 4 Ensite Pro Configuration Tool 21

22 Configure Data Inputs - Water TOR Select: B, J, L, M or ZLQ (the combination of water TOR ZLQ and level type Ullage is not possible. With level type Ullage, use water TOR L )*. - Water in Check to enable. foreground scan * refer to Table 1 on page 26 for additional information. Data Input - Temperature Temperature enabled Check to enable product temperature scan. - Element type Select: No element available, MRT, MRT with bottom spot, MRT with bottom and top spot, One spot element, Two spot element or MTT. - Lowest element Enter lowest temperature element position. Position Product temp. killed Check to disable product temperature scan. - Manual overwrite Enter manual product temperature. Note: Temperature enabled must be checked to be able to overwrite manually. Advanced settings The Advanced settings below get enabled if the advanced button is pressed or the embedded checkbox is checked. - Temp. address Enter product temperature transmission address. - Temp. TOI Select: A, B, C, E or M*. - Temp. TOR Select: C or ZAG*. - Temp. in Check to enable. foreground scan * refer to Table 1 on page 26 for additional information. 22 Ensite Pro Configuration Tool Part No.: Revision 4

23 Configure Data Inputs Data Input - Density HIMS (HTMS) enabled Check to enable density scan from HIMS configuration. Density dip enabled Check to enable density scan from servo gauge. - Min. dip level Enter minimum density level. Manual overwrite Advanced settings Enter manual (=observed) density together with the observed temperature. First enable HIMS/HTG or Density dip. The Advanced settings below get enabled if the advanced button is pressed or the embedded checkbox is checked. - Density address Enter density transmission address. - Density TOI Select: B, C or E*. - Density TOR Select: ZQQ*. - Density in foreground Check to enable. scan * refer to Table 1 on page 26 for additional information. Part No.: Revision 4 Ensite Pro Configuration Tool 23

24 Configure Data Inputs Data Input - Pressure Pressure enabled - Absolute pressure Select if applicable. - Relative pressure Select if applicable. Vapour pressure killed Check to enable vapour pressure scan. Check to disable vapour pressure scan. - Manual overwrite Enter manual vapour pressure. First enable Pressure. Advanced settings The Advanced settings below get enabled if the advanced button is pressed or the embedded checkbox is checked. - Pressure address Enter vapour pressure transmission address. - Pressure TOI Select: A, B, C, E or M*. - Pressure TOR Select: ZP3*. - Pressure in foreground Check to enable. scan * refer to Table 1 on page 26 for additional information. 24 Ensite Pro Configuration Tool Part No.: Revision 4

25 Configure Data Inputs Data Input - Vapour Vapour temperature enabled Check to enable vapour temperature scan. Vapour temperature killed Check to disable vapour temperature scan. - Manual overwrite Enter manual vapour temperature. First enable vapour temperature. Advanced settings The Advanced settings below get enabled if the advanced button is pressed or the embedded checkbox is checked. - V. Temp. address Enter vapour temperature transmission address. - V. Temp. TOI Select: A, B, C, E or M*. - V. Temp. TOR Select: C or ZAG*. - V. Temp. in Check to enable. foreground scan * refer to Table 1 on page 26 for additional information. Part No.: Revision 4 Ensite Pro Configuration Tool 25

26 Configure Data Inputs Data Input - Scan Field Display Indicator Scan enable Check to enable indicator scan. - Scan address Enter FDI transmission address. - Scan TOI Select: A, B, C, E or M*. - Scan TOR Select: B, C, J, L, M, ZAG, ZLQ, ZP3 or ZQQ*. - Scan in Check to enable. foreground scan * see Table 1 below for more information. Table 1 TOI TOR ZAG ZLQ ZQQ ZP3 A 802/812 gauge. B 811 gauge with GPU protocol and devices with gauge type=b. C 813 MGT and devices with gauge type=c. E 811 gauge with external alarms and devices with gauge type=e. M 816 /818. B Alarm status + [contact status] if TOI is C or E + product level. C Alarm status + [contact status] if TOI is C or E + temperature. J Alarm status + water level. L Alarm status + [contact status] if TOI is C or E + signed level. M Water alarm status + [contact status] if TOI is C or E + water level status + water level record. Average vapour temperature 854, 873, 877, 970, 971 & 973 only. Innage servo level 854 only. Abbreviated hydrostatic density 854, 866, 873, 877, 970, 971 & 973 only. Pressure sensor P3 854, 866, 873, 877, 970, 971 & 973 only. 26 Ensite Pro Configuration Tool Part No.: Revision 4

27 Configure Data Inputs Data Input - Tank Linked to tank This field displays the tank name on which the data input device is connected. This box is not editable. Part No.: Revision 4 Ensite Pro Configuration Tool 27

28 Configure tanks Select or enter a tank name. All tank related data can be entered in this section. Press the Copy -button to copy the highlighted tank name from the list. Only specific data must be changed afterwards. When the tank is not in the list (yet), a new tank has to be created. Press the New -button to add a tank: Press the Edit -button to edit data from the highlighted tank: - Tank - Vapour - Flow - TCT - Product - Shell - Roof Press the Delete -button to remove the highlighted tank from the list. If the tank is linked to a CIU or a data input is linked to this tank the tank cannot be deleted. 28 Ensite Pro Configuration Tool Part No.: Revision 4

29 Configure Tanks Tank Shape Level type Volume corr. Tank status Select the tank shape, visualising icon for this tank : Enraf default (0 = No shape defined, 1 = Cylindrical fixed roof, 2 = Cylindrical with floating roof, 3 = Cylindrical with internal floater, 4 = Spherical tank, 5 = Bullet, 6 = Underground bullet, 7 = Irregular cavern) : reserved for future expansion by Enraf : user defined tank shapes. Create your own tank icon, name it TankShape<nr.>.ico and place it in the \Pictures -subdirectory. Select Innage or Ullage/Outage Select - None (no Vapour Mass). - Tank available Check if available. - Tank scan disabled Check to disable. Advanced option - S&W corr. (Liq. Mass from NSV; no Vap. Mass). - Vapour calc. Liq/Vol Ratio ISO/TC28/SC 3 N. - Vapour calc. Molar Method ISO/TC28/SC 3 N. - Vapour calc. Method API research proj Vapour calc. Molar Method ISO The advanced air density option below gets enabled if the advanced button is pressed or the embedded checkbox is checked. - Air density In case the air density for this tank deviates from the one entered in global settings it can be manually be edited per tank. Part No.: Revision 4 Ensite Pro Configuration Tool 29

30 Configure Tanks Tank - Product Product name Enter the product s name. Corrections - GSV Calc Type + Select GSV calc type. See available types in the table below. - Range checking + If applicable for the selected GSV calc type, check to enable temperature and density range checking. - Ref. temperature + Enter local reference temperature if the text box is enabled according the table below. - Product code Select A, B, C or D if enabled for the selected GSV Calc type. GSV Calc Type Range checking Ref temperature Product code No GSV calc. Disabled Unchanged + disabled N.A. + disabled DCF Disabled Unchanged + enabled N.A. + disabled TCF Disabled Unchanged + enabled N.A. + disabled Manual CTL Disabled Unchanged + enabled N.A. + disabled ASTM-IP-52 23/24 Disabled 60 F + disabled E + disabled ASTM-IP-52 53/54 Disabled 15 C + disabled E + disabled D /6 Enabled 60 F + disabled A B C D D /24 Enabled 60 F + disabled A B C D /54 Enabled 15 C + disabled A B C D D /60 Enabled 20 C + disabled A B C D D /60 Alt T Enabled Unchanged + enabled A B C D D /6 Enabled 60 F + disabled A B C D D /24 Enabled 60 F + disabled A B C D D /54 Enabled 15 C + disabled A B C D D /60 Enabled 20 C + disabled A B C D D /60 Alt T Enabled Unchanged + enabled A B C D TP /24 Enabled 60 F + disabled E + disabled TP /54 Enabled 15 C + disabled E + disabled 30 Ensite Pro Configuration Tool Part No.: Revision 4

31 Configure Tanks TP /60 Enabled 20 C + disabled E + disabled TP /60 Alt T Enabled Unchanged + enabled E + disabled D Disabled 60 F + disabled N.A. + disabled D Disabled 15 C + disabled N.A. + disabled D Disabled 15 C + disabled N.A. + disabled D Disabled 15 C + disabled N.A. + disabled D Disabled 60 F + disabled N.A. + disabled Chemical #100 Disabled Unchanged + enabled N.A. + disabled Chemical #101 Disabled Unchanged + enabled N.A. + disabled Chemical #102 Disabled Unchanged + enabled N.A. + disabled Chemical #103 Disabled Unchanged + enabled N.A. + disabled Chemical #104 Disabled Unchanged + enabled N.A. + disabled Chemical #105 Disabled Unchanged + enabled N.A. + disabled Chemical #106 Disabled Unchanged + enabled N.A. + disabled Chemical #107 Disabled Unchanged + enabled N.A. + disabled Chemical #108 Disabled Unchanged + enabled N.A. + disabled Chemical #109 Disabled Unchanged + enabled N.A. + disabled Note: Disabled means Grayed out and Enabled Not Grayed out. It doesn t say anything about whether a checkbox is checked or unchecked. - TC Enter expansion factor in 10-7 / C (in case of product code C ). - CTL Enter volume correction factor. - TCF Enter temperature correction factor. - DCF Enter density correction factor. - S&W Enter sediment and water percentage. - Manual ref. density Enter the product s reference density. Mass Calculation - in air Select if applicable. - in vacuum Select if applicable. - HIMS/HTMS not allowed Check to disable Hybrid Inventory Management System. - HTG Check to enable Hydrostatic Tank Gauging. Press the Advanced -button to enable/disable volume calculation details: - VCF A selection can be made between standard calculations or rounding in 4 or 5 decimals. Part No.: Revision 4 Ensite Pro Configuration Tool 31

32 Configure Tanks Tank -Vapour Vapour calc. details Data in this tab can only be filled in if in the Tank -tab the Volume corrections is set to Vapour. - Liq/Vol. ratio Enter liquid to volume ratio (default = 250). - Molar value Enter molar weight of gas composition (default = 0). Vapour mass calculation - in air Select if applicable. - in vacuum Select if applicable. 32 Ensite Pro Configuration Tool Part No.: Revision 4

33 Configure Tanks Tank -Shell Tank shell calibrated (W&M) CTSh correction (acc. API Chapter 12.1) Check to enable. Check to enable tank shell expansion correction. - Tank shell exp. coeff Enter tank shell expansion coefficient. - Tank shell ref. temperature Enter tank shell reference temperature. - Insulation factor Enter tank shell insulation factor. This can be a figure between 0 and 1, in which 1 is for fully insulated tanks. Part No.: Revision 4 Ensite Pro Configuration Tool 33

34 Configure Tanks Tank -Flow Moving detection interval Moving detection trip Level Flow calculation Interval Flow calculation damping Enter interval time (in s) after which level increase/ decrease must be checked (default = 60 sec). Enter minimum trip level after which level increase/ decrease will be indicated (default = 0). Enter interval time (in s) after which volume increase/ decrease must be checked (default = 60 sec). Enter damping factor (0...1) for stable read-out (default = 0.15). 34 Ensite Pro Configuration Tool Part No.: Revision 4

35 Configure Tanks Tank -Roof Zone 1 Enabled - No GOV calculation - No Water Volume calculation - Weight - High - Low Zone 2 Enabled - No GOV calculation - No Water Volume calculation - Weight - High - Low Check to enable. Check to disable volume calculation when level is in zone 1. Check to disable. Enter the weight of the tank roof. Enter no-go-zone 1 high level. Enter no-go-zone 1 low level. Check to enable. Check to disable volume calculation when level is in zone 2. Check to disable. Enter extra weight. Enter no-go-zone 2 high level. Enter no-go-zone 2 low level. High/low zones The program will issue a warning if the low value is higher than the high value. Part No.: Revision 4 Ensite Pro Configuration Tool 35

36 Configure Tanks Tank -TCT Tank Capacity Table The format of this file can be found in the Instruction manual series 880 CIU Plus. Press the Browse -button to select a tank capacity table. Selected file will be copied to the data environment of the selected site (\Documents and settings\all Users\Application Data\Enraf\SiteDatabase\ Ensite Pro\[Site name]). The copied file will get the name [Tank name].txt. Press the View -button to view the tank capacity table. A selected strap table file will only be accepted if the used engineering units match the global selected engineering units of the site database. Water volume if no water found Shell capacity High level Low level Enter water volume. Enter shell capacity. Enter level that corresponds with high TOV (for graphical purposes in Entis Pro). Enter level that corresponds with low TOV (for graphical purposes in Entis Pro). 36 Ensite Pro Configuration Tool Part No.: Revision 4

37 Configure Tanks The application checks the high level to be higher than the low level for innage. If the tank is set up for ullage the high level value must be lower than the low level value. High TOV Low TOV Enter volume that corresponds with high level (for graphical purposes in Entis Pro). Enter volume that corresponds with low level (for graphical purposes in Entis Pro) The application checks the high TOV to be higher than the low TOV for innage. If the tank is set up for ullage the high TOV value must be lower than the low TOV. Tank -Links Linked via Data in this tab can only be viewed. No entry is possible. It shows the result of the Link actions. - Primary CIU Plus The name of the primary CIU Plus is displayed, via which the tank is connected. Linked via CIU Prime - Primary - Secondary The name of the primary CIU Prime is displayed, via which the tank is connected. The name of the secondary CIU Prime is displayed, via which the tank is connected. Linked via - Secondary CIU Plus The name of the secondary CIU Plus is displayed, via which the tank is connected. Linked via CIU Prime - Primary - Secondary The name of the primary CIU Prime is displayed, via which the tank is connected. The name of the secondary CIU Prime is displayed, via which the tank is connected. Part No.: Revision 4 Ensite Pro Configuration Tool 37

38 Configure CIU Prime The CIU Prime is an interface between the field instrumentation (e.g. 854 ATG, 873 SmartRadar, etc.) and inventory systems (CIU Plus, DCS, PLC, etc.). Press the Copy -button to copy the highlighted CIU Prime from the list. Only specific data must be changed afterwards. When the CIU Prime is not in the list (yet), a new CIU Prime has to be created. Press the New -button to add a CIU Prime: Press the Edit -button to edit data from the highlighted CIU Prime: - HostPort 1 - Hot standby - Tambient - HostPort 2 - FieldPorts Press the Delete -button to remove the highlighted CIU Prime from the list. A CIU Prime can only be deleted if no tanks are connected to any of the field ports and the HostPorts are not linked to a CIU Plus. 38 Ensite Pro Configuration Tool Part No.: Revision 4

39 Configure CIU Prime CIU Prime - HostPort 1 HostPort 1 and 2 are two fixed RS-232C/RS485 output boards interface to a CIU Plus, DCS, PLC, etc. For data acquisition there are four slots available in the CIU Prime. These slots can handle two different types of boards: - BPM (Bi-Phase Mark) to interface the Enraf field bus. - RS-232C/RS485 input board to interface the 858 CIU. All settings of the CIU Prime HostPorts have the same default settings as defined for the FieldPorts of the CIU Plus. This means that for HostPorts physically connected to the CIU Plus, none of the settings needs to be altered. - Config. name - RTU address - Baudrate Enter the name of the connected device (up to 10 characters). Enter the RTU address in the range 1 through 247 (default = 31). Note: Each RTU address must be unique in the site. Select 1200, 2400, 4800, 9600 or (default = 19200). Part No.: Revision 4 Ensite Pro Configuration Tool 39

40 Configure CIU Prime Modbus mapping - CIU Plus compliant - W&M sealed - User specified Advanced settings Select if a CIU Plus is connected to this port. All data will be filled in on pre-defined positions. Check if applicable. The Modbus mapping can be made compliant to other hosts than the CIU Plus. Selecting this radio button enables the Settings button. This button gets enabled if the radio button is set to user specified. Press this button to modify the Modbus mapping of this port. Refer to the chapter Modbus settings for details how to change the Modbus map. The Advanced settings below get enabled if the advanced button is pressed or the embedded checkbox is checked. - Stop bits - Parity - Turn-around delay - Duplex mode - Mode - Multi Party Select 1 or 2 (default = 1). Select Odd, Even or None (default = Odd). Enter reply waiting time in ms (default = 20 ms). Select Full or Half (default = Full). Select RS-232C or RS-485 (default = RS-232C). Select Point-to-point or Multi-drop (default = Point-to-point). If RS-232C is selected, while in reality RS-485 hardware is applied, communication can not be established. 40 Ensite Pro Configuration Tool Part No.: Revision 4

41 Configure CIU Prime CIU Prime - HostPort 2 All settings of the CIU Prime HostPorts have the same default settings as defined for the FieldPorts of the CIU Plus. This means that for HostPorts physically connected to the CIU Plus, none of the settings needs to be altered. - Config. name - RTU address - Baudrate Modbus mapping - CIU Plus compliant - W&M sealed - User specified Enter the name of the connected device (up to 10 characters). Enter the RTU address in the range 1 through 247 (default = 31). Note: Each RTU address must be unique in the site. Select: 1200, 2400, 4800, 9600 or (default = 19200). Select if a CIU Plus is connected to this port. All data will be filled in on pre-defined positions. Check if applicable. The Modbus mapping can be made compliant to other hosts than the CIU Plus. Selecting this radio button enables the Settings button. Part No.: Revision 4 Ensite Pro Configuration Tool 41

42 Configure CIU Prime This button gets enabled if the radio button is set to user specified. Press this button to modify the Modbus mapping of this port. Refer to the chapter Modbus settings for details how to change the Modbus map. Advanced settings The Advanced settings below get enabled if the advanced button is pressed or the embedded checkbox is checked. - CIU 858 compatible - MSU mode - Stop bits - Parity - Turn-around delay - Duplex mode - Mode - Multi Party Check to enable CIU emulation. By default the CIU Prime HostPort communication protocol is Modbus. By checking this checkbox this HostPort changes to the GPU protocol. Check to enable. Select 1 or 2 (default = 1). Select Odd, Even or None (default = Odd). Enter reply waiting time in ms (default = 20 ms). Select Full or Half (default = Full). Select RS-232C or RS-485 (default = RS-232C). Select Point-to-point or Multi-drop (default = Point-to-point). If RS-232C is selected, while in reality RS-485 hardware is applied, communication can not be established. 42 Ensite Pro Configuration Tool Part No.: Revision 4

43 Configure CIU Prime CIU Prime - Hot standby If any changes are made to any of the CIU Prime settings (while a hot standby counterpart is defined), the program will generate a warning to keep the configurations of both units synchronous. Hot standby enabled Check to enable hot standby functionality (default = unchecked). - Counterpart Select name of other CIU Prime. Hot standby mode Select Primary or Secondary (default = Primary). If Primary is selected, while no secondary CIU Prime exists, the hot standby facility can not be established. Part No.: Revision 4 Ensite Pro Configuration Tool 43

44 Configure CIU Prime CIU Prime - FieldPorts The setting in Poll strategy determines the sequence in which the FieldPorts are scanned: P = FieldPort scans parallel, without waiting for other FieldPorts. 1 = FieldPort scans in sequence with other FieldPorts with code 1 2 = FieldPort scans in sequence with other FieldPorts with code 2 Examples: PPPP = all ports scan parallel (= default). P111 = port 1 scans parallel; others scan sequentially = ports 1 and 2 and ports 3 and 4 scan in a separate sequence. PPP1 = all ports scan parallel (sequence 1 contains only one port). FieldPort 1, 2, 3, 4 - Type - Poll strategy Select None, CIU-GPU (= RS-communication) or BPM-GPU (= Enraf Fieldbus). Select: 1, 2 or P. Press the Settings -button to set the FieldPort communication settings. Changes to the FieldPort type must be applied first. 44 Ensite Pro Configuration Tool Part No.: Revision 4

45 Configure CIU Prime CIU Prime - FieldPort BPM-GPU Type Type BPM-GPU as selected in previous dialog. The type CIU-GPU is described in the next chapter. - Baudrate Select 1200, 2400, 4800, 9600 or Advanced settings The Advanced settings below get enabled if the advanced button is pressed or the embedded checkbox is checked. - Stopbits - Parity -Turn-around delay - Handshake - Multi party - Mode Not selectable. Set to 1 for GPU protocol. Not selectable. Set to Odd for GPU protocol. Enter reply waiting time in ms (default = 20 ms). Not selectable. Set to Full for GPU protocol. Not selectable. Set to Point-to-point for GPU protocol. Not selectable. Set to EN-BPM for GPU protocol. Part No.: Revision 4 Ensite Pro Configuration Tool 45

46 Configure CIU Prime FieldPort - Time-out - Sensitivity - Retries - Communication fail delay - Data fail delay Enter timeout in ms (default = 250 ms). Enter sensitivity in the range of 1 through 7 (default = 7). Enter number of retries in the range of 1 through 10 (default = 3). Enter a time between 0 and 255 seconds (default = 60). See note 1. Enter a time between 0 and 255 seconds (default = 60). See note 2. Note 1 When a field communication fail occurs it is possible to maintain last valid scan data in the CIU Prime database during a configurable amount of time. The communication fail delay mechanism is reset on the reception of data. A field communication fail can be caused by: - modem delays bad cabling. - no answer because of a re- initializing gauge. Note 2 When a data fail occurs it is possible to maintain the last valid scan data in the CIU Prime database during a configurable amount of time. The data fail mechanism is reset on the reception of valid data. A data fail can be caused by: - re-initialization of a gauge /811 digitizer failure. 46 Ensite Pro Configuration Tool Part No.: Revision 4

47 Configure CIU Prime CIU Prime - FieldPort CIU-GPU Type Type CIU-GPU as selected in previous dialog. - Baudrate Select: 1200 or Advanced settings The Advanced settings below get enabled if the advanced button is pressed or the embedded checkbox is checked. - Stopbits - Parity -Turn-around delay - Handshake - Multi party - Mode Select 1 or 2 (default = 1). Select Odd, Even or None (default = Odd). Enter reply waiting time in ms (default = 20 ms). Select Full or Half (default = Full). Select Point-to-point or Multi-drop (default = Point-to-point). Select RS-232C or RS-485 (default = RS-232C). Part No.: Revision 4 Ensite Pro Configuration Tool 47

48 Configure CIU Prime FieldPort - Time-out - Sensitivity - Retries - Communication fail delay - Data fail delay Enter timeout in ms (default = 250 ms). Disabled not applicable. Enter number of retries in the range of 1 through 10 (default = 3). Enter a time between 0 and 255 seconds (default = 60). See note 1. Enter a time between 0 and 255 seconds (default = 60). See note 2. Note 1 When a field communication fail occurs it is possible to maintain last valid scan data in the CIU Prime database during a configurable amount of time. The communication fail delay mechanism is reset on the reception of data. A field communication fail can be caused by: - modem delays bad cabling. - no answer because of a re- initializing gauge. Note 2 When a data fail occurs it is possible to maintain the last valid scan data in the CIU Prime database during a configurable amount of time. The data fail mechanism is reset on the reception of valid data. A data fail can be caused by: - re-initialization of a gauge /811 digitizer failure. If RS-232C is selected, while in reality RS-485 hardware is applied, communication can not be established. 48 Ensite Pro Configuration Tool Part No.: Revision 4

49 Configure CIU Prime CIU Prime - Tambient Tamb. Broadcast enable Check to enable. Ambient temperature scan - Tamb. scan enable - Tamb. Address Check to enable ambient temperature scan. - Tamb. TOI Enter ambient temperature transmission address. - Tamb. TOR Select A, B, C, E or M*. Select C or ZAG*. * refer to Table 1 on page 26 for additional information. Part No.: Revision 4 Ensite Pro Configuration Tool 49

50 Configure CIU Plus The CIU Plus calculates volume, standard volume, mass, density, flow rate, etc. It receives data from the CIU Prime and calculates all other data. It presents data to higher layered systems like Entis Pro, SCADA, DCS, etc. Press the Copy -button to copy the highlighted CIU Plus from the list. Only specific data must be changed afterwards. When the CIU Plus is not in the list (yet), a new CIU Plus has to be created. Press the New -button to add a CIU Plus: Press the Edit -button to edit data from the highlighted CIU Plus: - HostPorts - FieldPort 1 - Hot standby - FieldPort 2 Press the Delete -button to remove the highlighted CIU Plus from the list. The CIU Plus can only be deleted if no CIU primes are linked to any of its FiledPorts. 50 Ensite Pro Configuration Tool Part No.: Revision 4

51 Configure CIU Plus CIU Plus - HostPorts Up to four RS-232C/RS485 output boards can be installed to interface host communication (Modbus) to Entis Pro, SCADA, DCS, etc. By default one board is installed which communicates the Modbus protocol. For a description of the Modbus protocol, refer to the related instruction manual. For data acquisition two fixed RS-232C/RS485 input boards interface to a CIU Prime. HostPorts 1, 2, 3, 4 - Config. name - Type Enter a name, identifying the connected device (up to 10 characters). Select None or Modbus RTU. To be able to communicate with the CIU at least one Modbus is needed. Press the Settings -button to set the HostPort communication settings. Changes to the HostPort type must be applied first. Part No.: Revision 4 Ensite Pro Configuration Tool 51

52 Configure CIU Plus CIU Plus HostPort(s) RTU address Here the RTU address of the HostPort is displayed (default = 41). Note: All RTU addresses in a site should have a unique number. Baudrate Select 1200, 2400, 4800, 9600,19200 or Modbus mapping - Entis Pro conform - W&M sealed - User specified Select if Entis Pro is connected to this port. All data will be filled in on pre-defined positions. Check if applicable. The Modbus mapping can be made compliant to other hosts than the Entis system. Selecting this radio button enables the Settings button. This button gets enabled if the radio button is set to user specified. Press this button to modify the Modbus mapping of this port. Refer to the chapter Modbus settings for details how to change the Modbus map. Advanced settings The advanced settings below get enabled if the advanced button is pressed or the embedded checkbox is checked. 52 Ensite Pro Configuration Tool Part No.: Revision 4

53 Configure CIU Plus - Mode - Parity - Stopbits - Duplex mode - Turn around delay - Multi party Select RS-232C or RS-485 (Check the hardware). Select Odd, Even or None (default = Odd). Select 1 or 2 (default = 1). Select Full or Half (default = Full). Enter reply waiting time in ms (default = 20 ms). Select Point-to-point or Multi-drop (default = Point-to-point). CIU Plus - Hot standby If any changes are made to any of the CIU Plus settings (while a hot standby counterpart is defined), the program will warn to keep the configurations of both units synchronous. Hot standby enabled Check to enable hot standby functionality. - Counterpart Select name of other CIU Plus. Hot standby mode Select Primary or Secondary (default = Primary). If Primary is selected, while no secondary CIU Plus exists, the hot standby facility can not be established. Part No.: Revision 4 Ensite Pro Configuration Tool 53

54 Configure CIU Plus Connection Define the connection scheme. - CIU Prime connected The ports of the CIU Primes and Pluses must be to one Plus only. connected according to the diagram: - CIU Primes connected The ports of the CIU Primes and Pluses must be to both primary and connected according to the diagram: secondary Plus. 54 Ensite Pro Configuration Tool Part No.: Revision 4

55 Configure CIU Plus CIU Plus - FieldPorts 1 & 2 All settings of the CIU Plus Fieldports have the same default settings as defined for the HostPorts of the CIU Prime. This means that for fieldports physically connected to the Prime, none of the settings needs to be altered. Advanced settings The advanced settings below get enabled if the advanced button is pressed or the embedded checkbox is checked. - Baudrate - Parity - Stop bits - Turn around delay - Mode - Retries - FieldPort timeout - Duplex mode - Break signal - Multi party Select 1200, 2400, 4800, 9600 or (default = which is the default of HostPort of CIU Prime). Select Odd, Even or None (default = Odd). Select 1 or 2 (default = 1). Enter reply waiting time in ms (default = 0 ms) Select RS-232C or RS-485 (default = RS-232C). Enter number of retries (default = 3) Enter timeout in ms (default = 1100 ms) Select Full or Half (default = Full). Check to enable (default = unchecked). Select Point-to-point or Multi-drop (default = Point-to-point) If RS-232C is selected, while in reality RS-485 hardware is applied, communication can not be established. Part No.: Revision 4 Ensite Pro Configuration Tool 55

56 Communication setup (PC Serial Port) To be able to communicate with the CIU Plus and Prime the communication parameters of the PC serial port must be set. Connected to - Entis Pro - CIU Plus - CIU Prime Select if connected to Entis Pro. Named pipes communication is used to reach the field through Entis. Select if connected to a CIU Plus. Also select the CIU Plus and the according HostPort Select if connected to CIU Prime. Also select the CIU Prime and the according HostPort 56 Ensite Pro Configuration Tool Part No.: Revision 4

57 Communication Setup PC Port Settings - Comm. Port - Baudrate - Parity - Stopbits - Turn around delay - Retries - Reply timeout Select communication port of PC where configuration tool is installed. Select 1200, 2400, 4800, 9600, or (default = 19200). Select Odd, Even or None (default = Odd) Select 1 or 2 (default = 1) Select reply waiting time in ms (default = 10 ms) Enter the number of retries (default = 2) Enter the reply waiting time (default = 3000 ms) Press the Monitor -button to view communication. The following window is shown: Messages Received Transmitted Reset Client applications Stop presentation Connected to Number of total received messages and number of failed messages Total number of transmitted messages. Press the Reset -button to reset the message counters. Displays the number of applications (programs) running simultaneously Check to freeze data on the monitor. Displays the device this PC is connected to. Part No.: Revision 4 Ensite Pro Configuration Tool 57

58 Configure links After all individual components (CIU Prime, CIU Plus, tanks and data inputs) have been created and configured, they have to be linked to each other. To link an available instrument: Press the left mouse button on an element in the available list. Hold the button and drag it to the tree in the left pane and drop it by releasing the mouse button at the desired tree node. Unlink: Press the left mouse button on a node in the left pane, drag it to the available list and drop it there by releasing the mouse button. Link - Data inputs With this dialog created data Inputs can be linked to the Tank the data input is mounted to. - Available - Overview - Large Icons The left column displays the available tanks, the right column displays the available data inputs. Drag a data input from the right list to the tank where it is physically connected to. Pressing the overview pops-up a new dialog which shows all components in a tree view. Select large icons, small icons or no icons. The overview shows all CIU plusses and goes down to the instruments. If the link is broken between the CIU Plus and Prime the Prime and all connected elements will not be shown in the overview. 58 Ensite Pro Configuration Tool Part No.: Revision 4

59 Configure Links Link - Tanks With this dialog created tanks can be linked to the FieldPorts of the CIU Prime. The number of ports shown her depends on the ports created as described in paragraph CIU Prime FieldPorts. - Available The left column displays the available CIU Primes, the right column displays the available tanks. The number of fieldports connected to the prime depends on the number of ports configured. Refer to chapter CIU Prime FieldPorts. Drag a tank from the right list to one of the FieldPort of the CIU Prime where it is physically connected to and drop it. Part No.: Revision 4 Ensite Pro Configuration Tool 59

60 Configure Links Link CIU Prime to CIU Plus With this dialog HostPorts of created CIU Primes can be linked to one of the FieldPorts of the CIU Plus. Create the same link as the physical connected cable between the Plus and Prime. - Available The left column displays the available CIU Pluses, the right column displays the available CIU Primes. Each Plus in the left column shows two FieldPorts. Drag a HostPort of the CIU Prime from the right list to the FieldPort of the CIU Plus where it is physically connected to. Link - Overview This dialog shows the result of the linking process. It represents the physical connections of all Honeywell Enraf instruments of the site. Elements still listed in one of the available lists will not show up here. 60 Ensite Pro Configuration Tool Part No.: Revision 4

61 Download configuration The (new) programmed configuration must be downloaded for the CIU Prime / Plus to work with. In case a CIU Prime is connected to a Plus the CIU Prime must be downloaded first as the Plus requires the CRC s of Prime. After completion of receiving the data the CIU Plus calculates CRC over the configuration data. At the end of the download cycles Ensite Pro gets the CRCs and stores them in the database. For each download Ensite compares the CRCs in the database with the current CRCs of the CIU. Ensite uses this in combination with the changed flag per entity to determine what data to send. CIU Prime / CIU Plus - Name - CRC Displays the name of the available CIU s. Click on the name to select. The CIU Prime / Plus calculates an overall CRC over the settings. Ensite Pro fetches this CRC after a download and saves it in its database. The CRC status can be: Situation Color Text CRC OK Green Ok CRC unknown (not yet retrieved) Orange Unknown CRC wrong Red Mismatch The Unknown condition includes the situation where an earlier attempt to retrieve the CRC has failed due to a communication error. In case of such an error, the CRC status is always unchanged, whether it was green, orange or red. - Changed The Changed status can be Y or N (Yes/No). The status is Y if a new CIU is created or if any CIU setting is changed. The CRC status and the Changed status can change independently. Part No.: Revision 4 Ensite Pro Configuration Tool 61

62 Download Configuration Press the Monitor -button to view communication. The following window is shown: Please refer to the communications setup chapter for more details about this dialog. Pressing this button shows the dialog: Ensite Pro keeps track of the configuration changes made by the user. By default the program performs incremental downloads by sending the changes only. If for some reason changed configuration entities will not end-up in the list of data to download the Kill CRCs button can be pressed to force a full download for the selected CIU. Press the Check CRC -button to refresh the CRC status of the highlighted CIU. This means that the overall CRC is fetched from the CIU and compared with the stored CRC in the database. Press the Download -button to download the settings of the highlighted CIU. Depending on the CRC status and the Changed status a full or a partial (= only changed settings) download will be started. Press the INI-File -button to generate a number of files, needed for Entis Pro. The INI-files can only be generated after the whole configuration is downloaded in the CIU s. Hot standby In case of Hot standby proceed as follows: Download the Primary CIU Prime, Download the secondary CIU Prime, Download the Primary CIU Plus, Download the Secondary CIU Plus. When downloading through Entis Pro, the CIU Plus must be connected to HostPort 1. After a successful download, all manual overwrite values in the Ensite Pro settings database will be cleared. 62 Ensite Pro Configuration Tool Part No.: Revision 4

63 Upload configuration This function is standard disabled in the toolbar. It is only available for experienced users. Contact factory. By using this dialog the configuration of a CIU Prime / Plus can be uploaded to a new database. Note that a much higher accuracy will be reached by making a backup regularly. CIU Prime / CIU Plus - Name - CRC Displays the name of the available CIU s. Click on the name to select. The CIU Prime / Plus calculates an overall CRC over the settings. Ensite Pro fetches this CRC after a download and saves it in its database. The CRC status can be: Situation Color Text CRC OK Green Ok CRC unknown (not yet retrieved) Orange Unknown CRC wrong Red Mismatch The Unknown condition includes the situation where an earlier attempt to retrieve the CRC has failed due to a communication error. In case of such an error, the CRC status is always unchanged, whether it was green, orange or red. Changed The Changed status can be Y or N (Yes/No). The status is Y if a new CIU is created or if any CIU setting is changed. The CRC status and the Changed status can change independently. Part No.: Revision 4 Ensite Pro Configuration Tool 63

64 Upload Configuration Press the Monitor -button to view communication. The following window is shown: Please refer to the communications setup chapter for more details about this dialog. Pressing this button shows the dialog: Ensite Pro keeps track of the changes. By default the program performs incremental downloads. If for some reason changed configuration entities will not end-up in the list of data to download the Kill CRCs button can be pressed to force a full upload for the selected CIU. Always disabled. Note that the upload process will not recreate the strapping table files. Press the Check CRC -button to refresh the CRC status of the highlighted CIU. This means that the overall CRC is fetched from the CIU and compared with the stored CRC in the database. Press the Upload -button to upload the settings of the highlighted CIU. When uploading through Entis Pro, the CIU Plus must be connected through HostPort Ensite Pro Configuration Tool Part No.: Revision 4

65 Modbus settings The CIU Plus and Prime represent the data of their internal database in the Modbus area of the host ports. The Modbus mapping of ports not in use by the Entis Pro system (CIU Plus HostPorts not connected to any Entis Pro station and/or CIU Prime HostPorts not connected to any CIU plus) can be Modified to become compliant with third party Modbus hosts. To call the dialogs described here the hostport of the CIU plus or Prime must be set to user specified. Refer to the chapters CIU Prime HostPort n and CIU Plus - HostPort(s). Modbus settings - Data Data Orientation - Start address - Record interval Select: Tank oriented (= data grouped by tank) or Data oriented (= data grouped by entity). Enter start address (default = 0). Enter the number of registers between tank records (default = 0050 for the Plus/Prime) Advanced - Always force Data output to Fail if validity indicates failure. - Upon Prime Plus comm.fail. Force data output to Fail Select to force the Modbus registers to FFFFF in case of invalid data. If not selected the last measured value will be stored. Select to force the Modbus registers to FFFFF in case of invalid data. If not selected the last measured value will be stored. Part No.: Revision 4 Ensite Pro Configuration Tool 65

66 Modbus Settings Modbus settings - Tanks Tanks Available Tanks in User Record This column displays all available tanks. Press the arrow up -button to move the highlighted tank in the Tanks in User Record -column one position up. Press the arrow down -button to move the highlighted tank in the Tanks in User Record -column one position down. Press the arrow right right -button to move all tanks to the Tanks in User Record -column. Press the arrow left left -button to move all tanks to the Tanks Available -column. Press the arrow right -button to move the highlighted tank in the Tanks Available -column to the Tanks in User Record -column. Press the arrow left -button to move the highlighted tank in the Tanks in User Record -column to the Tanks Available -column. This column displays all tanks, selected for communication. When links are changed (adding, moving or deleting tanks) after having the Modbus mapping input, the Modbus mapping of tanks will be reset to default. Press the Default -button to restore all default settings. 66 Ensite Pro Configuration Tool Part No.: Revision 4

67 Modbus Settings Modbus settings - Entities Available Entities Definitions: # Name Type Size Scale Offset Entity This column displays all available entities. Press the arrow up -button to move the highlighted entity in the ID -column one position up. Press the arrow down -button to move the highlighted entity in the ID -column one position down. Press the arrow left left -button to move all entities in the ID -column to the Available Entities -column. Press the arrow right right -button to move all entities in the Available entities -column to the ID -column. Press the arrow left -button to move the highlighted entity in the ID -column to the Available Entities -column. Press the arrow right -button to move the highlighted entity in the Available entities -column to the ID -column. Entity ID number. Entity name Entity type / dimension. Number of registers. Scaling factor. Offset value. When in the list an entity is highlighted, it is possible to change the type, size, scale and/or offset. Press the Default -button to restore Entis Pro default default settings. Part No.: Revision 4 Ensite Pro Configuration Tool 67

68 Service note(s) When information about the current site must be stored, the build in text editor gives the possibility to do that. The contents get stored in the application configuration database. 68 Ensite Pro Configuration Tool Part No.: Revision 4

69 Set date and time New Date & Time - Hours - Mins - Secs - Month - Year Daylight Saving Time ON Select Select Select Select January, February, March, April, May, June, July, August, September, October, November or December. Select Check to change to change to DST (daylight saving time). The CIU does not switch automatically from winter time to summer time and back again. Part No.: Revision 4 Ensite Pro Configuration Tool 69

70 Print configuration All configuration settings of the elements (site, CIU Prime, CIU Plus, tank, data input) created in this site can be printed to have a hard back-up. The user can also print information how all elements are linked and the contents of the tank records and how this data is organised in Modbus registers. 70 Ensite Pro Configuration Tool Part No.: Revision 4

71 Print Configuration Site - Global settings - CIU Plus - CIU Prime - Tank settings - Data inputs Link information Modbus mapping Service notes Entity definition Select print template (default = Site.rpt) Check to print Global settings. Check to print CIU Plus settings; select CIU name and HostPort. Check to print CIU Prime settings; select CIU name and HostPort. Check to print tank settings; select name. Check to print data input settings; select name. Select print template (default = LinkOverview.rpt). Select print template (default = ModbusMapping.rpt). Select print template. Select print template (default = Entity99.rpt). Press the Preview -button to see how the print-out will look like. Press the Print -button to activate the printer and print the configuration. This icon on the print preview dialog can be used to export the report to a file instead of sending it to the printer. By pressing this icon in the print preview screen a dialog with printer settings will show up. If the Printer Setup -button is disabled the small icon In the print preview dialog can be used to set the printer parameters. Part No.: Revision 4 Ensite Pro Configuration Tool 71

72 Show diagnostic data This window displays all diagnostic data (serial number, software version, run hours, last fatal error) of the selected CIU Prime/Plus. Column description Entity = entity number Description = entity name Index = entity index value DataSetIndex = where does this data come from Value = entity value Press the Print -button to activate the printer and print the diagnostic data. Press the Update -button to fetch the current values from the selected CIU Prime/Plus and fill in the Value -column. Database analysis In order to analyse an erroneous database of the CIU a printout can be made. To avoid sending a fax and files separately it is possible to store the diagnostic printouts into files by pressing the envelope icon of the report form. Pressing this icon the Export window will pop up. Select the Format and the Destination. Change the file name and store it. If you now create a ZIP-file of the complete site the diagnostic is included. You can now the file. Backup Making a backup can done as follows: Use the Window explorer and locate the root directory of the site (C:\Documents and Settings\All Users\Application Data\Enraf\ SiteDatabase\Ensite Pro\[Site Name]). Make a copy of this folder to another location. Preferred on another device like a USB disk. 72 Ensite Pro Configuration Tool Part No.: Revision 4

73 Show Diagnostic Data Press the R/W Data -button to read values from and/or write new values to the CIU Prime/Plus: Request Press the Jump to -button to select the entity, matching the number in the field Entity. The text of the Jump to button will change into Filter - Entity - Index - Data set index - Value Press the Filter -button to select the entities, starting with the number in the field Entity. Enter the required entity number. Enter the index value of the entity. Select the tank number where this index relates to. Enter the value to be written. The value entered will be interpreted according the radio button Dec. or Hex. Response - Value Here the response to the request above is given This is a read/only data field. The radio button changes the displayed value between decimal and hexadecimal. Press the Enter conf -button to go into configuration mode. It is now possible to write entities. Press the Exit conf -button to go out of configuration mode. It is now not possible o write entities. Press the Read -button to retrieve the value of the requested entity. Part No.: Revision 4 Ensite Pro Configuration Tool 73

74 Show Diagnostic Data Press the Write -button to overwrite the value of the requested entity. If this button is pressed in normal mode the following dialog appears: In that case press the Enter conf. -button first and retry to write the new value. The entity detail information can be enabled by pressing the books icon which results in enlarging the dialog like: - Details The detail tab in the right pane gives details about the selected entity. - location The location tab in the right pane shows information of the entity where it can be located. The example below shows the Tank entity tank status which gets stored in the CIU Prime and Plus. - dataset If an entity is located in the CIU Plus or Prime the dataset frame will show what dataset is holding the data. Like in the example below the HostPort baud rate item is located in the four HostPorts of the CIU. The dataset shows the data if the mouse is moved over the device in the location frame. 74 Ensite Pro Configuration Tool Part No.: Revision 4

75 Advanced Settings Clear Configuration Clear Novram With the procedure below all configuration settings of the CIU can be set to default. The clear configuration procedure should only be done when an existing database must be replaced by a new one. This procedure should not be done in case of modifying an existing database. Click on the R/W button in the Diagnostic window. Enter 7502 in the Entity/name field and hex 30 in the value field and press the Write -button. Within a few seconds the CIU will be reset. The CIU Prime will indicate this by simultaneous flashing the receive and transmit LEDs of the installed IP modules. On the CIU Plus a window will pop up with the message Letterbox empty caused by reset of CIU. To be sure that the CIU has completed the previous command, read the CIU name (Prime entity 502 and Plus entity 602) The name should be default ( DefPrime for the CIU prime and DefPlus for CIU Plus). The clear Novram procedure should only be done when an existing database must be replaced by a new one. This procedure should not be done in case of modifying an existing database. Click on the R/W button in the Diagnostic window. Enter 7507 in the Entity/name field and press the Write -button. Within a few seconds the CIU will be reset. The CIU Prime will indicate this by simultaneous flashing the receive and transmit LEDs of the installed IP modules. On the CIU Plus a window will pop up with the message Letterbox empty caused by reset of CIU To be sure that the CIU has completed the previous command, read the CIU name (Prime entity 502 and Plus entity 602) The name should be default ( 0 for the CIU Prime and CIUPlus for CIU Plus). Part No.: Revision 4 Ensite Pro Configuration Tool 75

76 Tank viewer The tank viewer displays all details for a single tank. CIU Tank Product Select the CIU Prime/Plus. Select the tank. Here the product name is displayed. (CIU) (Tank) (Product) Global settings Field data Inventory data Reference data This table shows what data is displayed in the in the different sections of the tank viewer dialog. Press the Print -button to activate the printer and print a screen dump of the tank viewer dialog. Additional Information From most values in this dialog, the program shows validity and status information. By moving over the values, the program shows the hex value like in the picture below. By a left click on such info a dialog with more details pops up. 76 Ensite Pro Configuration Tool Part No.: Revision 4

77 Scan viewer The scan viewer displays the scanning sequence, showing the data inputs being requested. CIU Column description Measured data statuses Select CIU to work with. Tank name = tank name. # = scan sequence nr. PL = product level. WL = water level. PT = product temperature. VT = vapour temperature. AT = ambient temperature. VP = vapour pressure. OD = observed density. FG-time = time of last foreground scan. BG-time = time of last background scan. The displayed status is build up out of two characters, being: 1st character: F = foreground scan. B = background scan. X = not scanned 2nd character: - = measured data K = killed data & = manual data F = communication fail Press the Print -button to activate the printer and print a screen dump of the scan viewer dialog. Part No.: Revision 4 Ensite Pro Configuration Tool 77

78 Help Click on this icon for on-line assistance. 78 Ensite Pro Configuration Tool Part No.: Revision 4

79 User privileges The configuration tool can be operated by different users. The list box displays all users that already exist. Press the New User -button to add a new user to the list. The following dialog will pop up. - Name - Password - Confirm password Enter user name. Enter password. Enter the same password again to confirm. Part No.: Revision 4 Ensite Pro Configuration Tool 79

80 User Privileges Press the Change Password -button to change the password of a user that already exists: - Old password - New password - Confirm new password Enter the old password. Enter the new password. Enter new password again to confirm. Press the Delete -button to remove the highlighted user from the list. 80 Ensite Pro Configuration Tool Part No.: Revision 4

81 Stop Ensite Pro To stop the configuration tool, press the X -button in the upper right corner of the dialog containing the toolbar. Next, the action has to be confirmed: After confirmation, the configuration tool window will be closed. To use the configuration tool again, is has to be (re-)started. Part No.: Revision 4 Ensite Pro Configuration Tool 81

Installation guide Ensite Pro Configuration Tool

Installation guide Ensite Pro Configuration Tool Installation guide Ensite Pro Configuration Tool July 2008 Part no.: 4416.594 Rev.3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel.: +31 15 2701100 Fax: +31 15 2701 111 Email: Info@enraf.nl http://www.enraf.com

More information

Instruction manual CIU Prime type 880 (CIU858 emulation)

Instruction manual CIU Prime type 880 (CIU858 emulation) Instruction manual CIU Prime type 88 (CIU858 emulation) Version.2 November 2 Part no.: 446529 Enraf B.V. P.O. Box 82 26 AV Delft Netherlands Tel.: +3 5 26986, Fax: +3 5 269574 Email: Info@enraf.nl http://www.enraf.com

More information

Instruction manual XPU-2 option RS-232C / RS-485

Instruction manual XPU-2 option RS-232C / RS-485 Instruction manual XPU-2 option RS-232C / RS-485 December 2006 Part no. 4416.237 Rev. 2 Copyright 1997-2006 Enraf B.V. All rights reserved. Reproduction in any form without the prior consent of Enraf B.V.

More information

Entis Pro OPC Server. Entis Pro OPC Server

Entis Pro OPC Server. Entis Pro OPC Server Entis Pro OPC Server Entis Pro OPC Server Copyright 2001-2009 Enraf BV, All rights reserved. Reproduction in any form without the prior consent of Enraf B.V. is not allowed. This manual is for information

More information

Instruction manual series 880 CIU Plus

Instruction manual series 880 CIU Plus Instruction manual series 880 CIU Plus May 2009 Part no.: 4416.526 Rev. 5 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

Engauge Quick Start Guide

Engauge Quick Start Guide Engauge Quick Start Guide Engauge Quick Start Guide Part nr.: 4417.483 Release build: 2.4.3889.0 Rev: 1 October 2010 Honeywell Enraf P.O. Box 812 2600 AV Delft Netherlands Tel: +31 15 2701 100 Fax: +31

More information

SmartLink Configuration Manual

SmartLink Configuration Manual SmartLink Configuration Manual October 2012 Part No. 4417554 Revision 2 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com Website

More information

Installation Guide Entis Pro Attention Scan

Installation Guide Entis Pro Attention Scan Installation Guide Entis Pro Attention Scan February 2013 PART NO: 4416387 REV.0 Attention Scan Installation Guide 1 Preface This guide describes how to install, configure and operate the Entis Pro Attention

More information

CIU 888 R101. Global Experience. Locally Applied. The next generation CIU for reliable, accurate gauge and inventory data.

CIU 888 R101. Global Experience. Locally Applied. The next generation CIU for reliable, accurate gauge and inventory data. CIU 888 R101 The next generation CIU for reliable, accurate gauge and inventory data. The 888 series Communication Interface Unit (CIU) is the critical link between tank gauging equipment and control room

More information

Connected Industrial ENRAF TANK FARM GATEWAY CIU 888. The next generation CIU for reliable, accurate gauge and inventory data

Connected Industrial ENRAF TANK FARM GATEWAY CIU 888. The next generation CIU for reliable, accurate gauge and inventory data Connected Industrial ENRAF TANK FARM GATEWAY CIU 888 The next generation CIU for reliable, accurate gauge and inventory data Honeywell s Enraf Tank Farm Gateway CIU 888 is the critical link between tank

More information

Reference Manual EN, Edition 3B September 2007 FCU 2165/2175. Field Communication Unit.

Reference Manual EN, Edition 3B September 2007 FCU 2165/2175. Field Communication Unit. Reference Manual FCU 2165/2175 Field Communication Unit www.rosemount-tg.com Reference Manual Rosemount Tank Radar REX Rosemount Tank Radar REX Tank Gauging System NOTICE Read this manual before working

More information

Technical Information Tankvision Professional NXA85

Technical Information Tankvision Professional NXA85 TI00448G/00/EN/15.16 71348968 Products Solutions Services Technical Information Tankvision Professional NXA85 Tank Gauging Advanced tank gauging and inventory management system Application Tankvision Professional

More information

Instruction manual ENSITE Service Tool

Instruction manual ENSITE Service Tool Instruction manual ENSITE Service Tool September 2007 Part no. 4416.587 Rev. 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel.: +31 15 2701100 Fax: +31 15 2701111 Email: Info@enraf.nl http://www.enraf.com

More information

Instruction manual 877 Field Display & Interface

Instruction manual 877 Field Display & Interface Instruction manual 877 Field Display & Interface Instruction manual 877 FDI Field Display & Interface February 2010 Part no. 4416257 Revision 4 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. :

More information

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/ Rev. A 1/25/213 172 Contents Contents Temperature-Humidity Sensor Configuration Tool... 3 Read Sensor Screen... 3 Manual Calibration Screen... 4 Register View Screen... 5 Modbus Registers... 6 Reprogram

More information

Operating Instructions and Description of Instrument Function Prothermo NMT539

Operating Instructions and Description of Instrument Function Prothermo NMT539 BA01026G/08/EN/19.15 71308663 Products Solutions Services Operating Instructions and Description of Instrument Function Prothermo NMT539 Temperature Basic Device Layout of Prothermo NMT539 Prothermo NMT539

More information

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU) Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU) Rev. 2 September 2012 Part No. 4417552 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax :

More information

IS35 Color Display. User Manual ENGLISH. simrad-yachting.com

IS35 Color Display. User Manual ENGLISH. simrad-yachting.com IS35 Color Display User Manual ENGLISH simrad-yachting.com Preface Navico is continuously improving this product, therefore we retain the right to make changes to the product at any time which may not

More information

Operating Instructions Tankvision NXA820 OPC Server

Operating Instructions Tankvision NXA820 OPC Server BA01137G/00/EN/03.17 71387780 Valid as of software version: V 02.01.00 Products Solutions Services Operating Instructions Tankvision NXA820 OPC Server User Manual Tankvision 1. Order code: XXXXX-XXXXXX

More information

M2500 Engine Controller Configuration Manual

M2500 Engine Controller Configuration Manual M2500 Engine Controller Configuration Manual Revision: 08-04-2011 Page 1 Contents 1 Preface... 4 2 Configuration from front panel... 5 2.1 Engine Controller Configuration... 6 2.1.1 RPM settings... 6 2.1.2

More information

MCG MCG 3900 Inventory Management System. Inventory Management System. Applications

MCG MCG 3900 Inventory Management System. Inventory Management System. Applications MCG 3900 The L&J Engineering WINGauge Version 5 Inventory Management System is the latest in a long line of tank gauging and inventory control and management products from L&J Technologies Inc. As a state

More information

Serial Connection of HC900 Hybrid Controller to 900CS Control Station

Serial Connection of HC900 Hybrid Controller to 900CS Control Station Note: Ethernet connections will provide faster performance than RS-485 HC900 1. Remove HC900 CPU and set S2 Dip Switches for RS-485 unterminated Replace CPU & follow instructions per Installation and User

More information

USER MANUAL WINATEQ300 SOFTWARE Full version 1.01

USER MANUAL WINATEQ300 SOFTWARE Full version 1.01 USER MANUAL WINATEQ300 SOFTWARE Full version 1.01 Reference: UM-Winateq300Fa-U AVERTISSEMENTS This document and the software which is provided with it are the exclusive property of ATEQ. The Winateq300

More information

FT2 View Instruction Manual

FT2 View Instruction Manual 399 Reservation Road, Marina, California U.S.A. Ph: (831) 384-4300 Fax: (831) 337-5786 www.foxthermalinstruments.com 2006 Fox Thermal Instruments, Inc. 07/19/13 Introduction: The FT2 View application software

More information

HART/ Modbus TCP Gateway GT200-HT-MT User Manual V 1.2 REV A SST Automation

HART/ Modbus TCP Gateway GT200-HT-MT User Manual V 1.2 REV A SST Automation HART/ Modbus TCP Gateway GT200-HT-MT User Manual V 1.2 REV A SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 Product Overview... 4 1.1 Product Function...4 1.2 Product Features...

More information

Flo-Ware. Discovering. Model 260/268 Flo-Tote System Manual. Version 3.1. Instrument & Data Management System for Windows 95,98 & NT

Flo-Ware. Discovering. Model 260/268 Flo-Tote System Manual. Version 3.1. Instrument & Data Management System for Windows 95,98 & NT Discovering Flo-Ware TM Instrument & Data Management System for Windows 95,98 & NT Year 2000 Compliance Open System Instrument Communications Data Management Data Editing Presentation Quality Charts Text

More information

Podium Plus Data Analysis Software. User Manual. SWIS10 Version

Podium Plus Data Analysis Software. User Manual. SWIS10 Version SWIS10 Version Issue 1.10 February 2005 Contents 1 Introduction 6 1.1 What is Podium Plus? 6 1.2 About This Manual 6 1.3 Typographical Conventions 7 1.4 Getting Technical Support 7 2 Getting Started 8

More information

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.: Technical Documentation with Modbus Procol Edition: 2017-04 Version: 1 Art. no.: 350253 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany Tel.: +49 / 40 / 39 82 07-0 Fax: +49 / 40 / 390 63 39

More information

Description of Instrument Functions Tank Side Monitor NRF590

Description of Instrument Functions Tank Side Monitor NRF590 BA00257F/00/EN/13.13 71241244 Valid as of software version: V02.04.zz Products Solutions Services Description of Instrument Functions Tank Side Monitor NRF590 Inventory Control Software Version 02.04.zz

More information

SECTION 5 HSLRT6 WINDOWS BASED SETUP PROGRAM REFERENCE

SECTION 5 HSLRT6 WINDOWS BASED SETUP PROGRAM REFERENCE The Windows based set-up program is menu driven, allowing the user to easily view data, alter setup variables or set machine timing (machine offset, timing signal locations, etc.), using a PC running the

More information

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str. FLOWgate500 Software Manual Software Manual FLOWgate500 Release 2.2 Revision number: V2.2 Manufacturer: SICK AG Erwin-Sick-Str.1 D-79183 Waldkirch Germany Place of manufacture: SICK Engineering GmbH Bergener

More information

Digital Data Manager Model 747

Digital Data Manager Model 747 Digital Data Manager Model 747 Staff Guide 3M Library Systems 3M Center, Building 225-4N-14 St. Paul, Minnesota 55144-1000 www.3m.com/library Copyright 2000, 2001, 2002 3M IPC. All rights reserved. 75-0500-4514-4,

More information

PROCESS ANALYSERS. SERVOTOUGH OxyExact (2200) Operator Manual. Part Number: 02210/001A Revision: 4 Language: UK English

PROCESS ANALYSERS. SERVOTOUGH OxyExact (2200) Operator Manual. Part Number: 02210/001A Revision: 4 Language: UK English PROCESS ANALYSERS SERVOTOUGH OxyExact (2200) Operator Manual Part Number: 02210/001A Revision: 4 Language: UK English This page intentionally blank xendos 2200 Operator Manual Ref: 02210/001A/4 Order as

More information

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND OleumTechTM TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND MUST BE FAMILIAR WITH LEVEL 1 TRAINING MATERIALS BEFORE MOVING FORWARD Doc ID# 80-6010-001b TABLE OF CONTENTS 1. WHAT IS NEW WRITE IMPORT

More information

4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM100(1402)

4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM100(1402) 4511 MODBUS RTU Configuration Manual 4131 Universal trip amplifier 4131MCM100(1402) 4131 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and

More information

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation HART / EtherNet/IP Gateway GT200-HT-EI V 1.0 REV A SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 Product Overview... 4 1.1 Product Function...4 1.2 Product Features... 4 1.3 Technical

More information

ArcTrak Plus. Operation / Installation Manual. Micro Arc Data Monitor Statistical Analysis Program. Computer Weld Technology, Inc.

ArcTrak Plus. Operation / Installation Manual. Micro Arc Data Monitor Statistical Analysis Program. Computer Weld Technology, Inc. Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com ArcTrak Plus Micro Arc Data Monitor Statistical Analysis

More information

Gas Chromatograph Software Interface User Manual (for FloBoss 107)

Gas Chromatograph Software Interface User Manual (for FloBoss 107) Form A6248 Part D301345X012 June 2017 Gas Chromatograph Software Interface User Manual (for FloBoss 107) Remote Automation Solutions Revision Tracking Sheet June 2017 This manual may be revised periodically

More information

Service Manual Tank Side Monitor. Description of Instrument Functions. Automation Solutions for oil & gas, defense and aviation applications

Service Manual Tank Side Monitor. Description of Instrument Functions. Automation Solutions for oil & gas, defense and aviation applications ispatch and Fuels Accounting 4590 Tank Side Monitor Description of Instrument Functions SRM006FVAE0510 Inventory Control Software v_02.04 Service Manual Automation Solutions for oil & gas, defense and

More information

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM100(1402)

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM100(1402) 4511 MODBUS RTU Configuration Manual 4114 Universal transmitter 4114MCM100(1402) 4114 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and factory

More information

Model 2000 Programmer EnSonic Display & Control Unit. Document code: M2KCNF.001

Model 2000 Programmer EnSonic Display & Control Unit. Document code: M2KCNF.001 Model 2000 Programmer EnSonic Display & Control Unit Document code: 10735.M2KCNF.001 Document Model 2000 Programmer: EnSonic Display & Control Unit Document code 10735.M2KCNF.001 Date January 25, 2004

More information

Thermal Mass Flowmeter

Thermal Mass Flowmeter User Manual UM/FMT/SW-EN Thermal Mass Flowmeter Sensyflow FMT Sizing & Selection Software Contents Contents 1 Software Description... 2 1.1 System requirements... 3 2 Introduction... 4 3 Documentation...

More information

Fox Thermal Instruments, Inc.

Fox Thermal Instruments, Inc. Fox Thermal Instruments, Inc. THERMAL MASS FLOW METER & TEMPERATURE TRANSMITTER FT2A View www.foxthermalinstruments.com 399 Reservation Road Marina, CA. 93933 105406 Rev. A Notice FOX THERMAL INSTRUMENTS

More information

DataPro Designer Quick Start Guide

DataPro Designer Quick Start Guide DataPro Designer Quick Start Guide Introduction The DataPro Designer application provides the user with the ability to configure the ULTRA-LITE PRO range of Auto Meter data acquisition products. Using

More information

T e s t C e r t i f i c a t e

T e s t C e r t i f i c a t e T e s t C e r t i f i c a t e Page : 1 of 1 Issued by In accordance with Manufacturer Part NMi Certin B.V. Article 6, first paragraph, of the "Metrologiewet". Enraf Delftechpark 39 2628 XJ Delft The Netherlands

More information

AWLaunch. Software Manual. Version 1.2 Last Revised April 27, 2009

AWLaunch. Software Manual. Version 1.2 Last Revised April 27, 2009 AWLaunch Software Manual Version 1.2 Last Revised April 27, 2009 All contents in this manual are copyrighted by ArWest Communications. All rights reserved.the information contained herein may not be used,

More information

8130 Remote Terminal Unit

8130 Remote Terminal Unit 830 Remote Terminal Unit Collect and transmit data from multiple storage tanks to a central system or host using a single tank gauge interface Benefits and Features Easily expandable through the use of

More information

Short description protocol ES40

Short description protocol ES40 Short description protocol ES40 Version 1.4 1. Intended use. The ES40 communication protocol is intended for data exchange between Cargomaster and other computer units. Its main property is ease of implementation

More information

DriveWare. User s Guide DriveBrowser

DriveWare. User s Guide DriveBrowser DriveWare User s Guide DriveBrowser DriveBrowser User s Guide Code: 3AUA0000024806 EN EFFECTIVE: 31.12.2008 SUPERCEDES 31.01.2008 2008 ABB Oy. All rights reserved. 5 Table of contents Table of contents...

More information

SoftTools Suite 7.0. Flowserve Corporation

SoftTools Suite 7.0. Flowserve Corporation SoftTools Suite 7.0 Quick Start Guide for SoftTools 7.0 with support for the HART Communications Protocol on the Logix 1200/1200e, 3200IQ, and 500/500si Series Positioners Flowserve Corporation Flow Control

More information

IntesisBox MAPS. Configuration & monitoring software of IntesisBox KNX series. User's manual Issue Date: 06/17 r1.0 eng

IntesisBox MAPS. Configuration & monitoring software of IntesisBox KNX series. User's manual Issue Date: 06/17 r1.0 eng IntesisBox MAPS Configuration & monitoring software of IntesisBox KNX series User's manual Issue Date: 06/17 r1.0 eng Intesis Software S.L.U. 2017 All Rights Reserved. Information in this document is subject

More information

Maxiflex Single Harwell NIM M1588 User Manual

Maxiflex Single Harwell NIM M1588 User Manual Maxiflex Single Harwell NIM M1588 User Manual SCOPE This document describes the installation, configuration and use of the Maxiflex M1588 Single Harwell NIM. This version of the manual refers to the NIM

More information

RMx621. Appendix to the operating manual

RMx621. Appendix to the operating manual Appendix to the operating manual RMx621 DP-slave module ( PROFIBUS-coupler ) from V2.01.00 Connecting the RMx621 to PROFIBUS DP via the RS485 serial interface using the external module (HMS AnyBus Communicator

More information

4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM101(1445) For 4511 devices from ser. no:

4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM101(1445) For 4511 devices from ser. no: 4511 MODBUS RTU Configuration Manual 4131 Universal trip amplifier 4131MCM101(1445) For 4511 devices from ser. no: 141590001 4131 CONTENTS Introduction... 1 Modbus basics... 1 Modbus RTU... 1 4511 Supported

More information

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw www.gc5.pl Table of content 1 Introduction... 4 1.1 Revision history... 5 1.2 Safety rules... 5 1.3 Technical specifications... 6 1.4

More information

Download Software User Guide Software Version

Download Software User Guide Software Version Download Software User Guide Software Version 1.3.51 AMALGAMATED INSTRUMENT CO PTY LTD ACN: 001 589 439 Unit 5, 28 Leighton Place Hornsby Telephone: +61 2 9476 2244 e-mail: sales@aicpl.com.au NSW 2077

More information

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM101(1445) For 4511 devices from ser. no:

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM101(1445) For 4511 devices from ser. no: 4511 MODBUS RTU Configuration Manual 4114 Universal transmitter 4114MCM101(1445) For 4511 devices from ser. no: 141590001 4114 CONTENTS Introduction... 3 Modbus basics...3 Modbus RTU...3 4511 Supported

More information

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Installation and commissioning guide SmartLink PSD Power Supply Module (DC) Installation and commissioning guide SmartLink PSD Power Supply Module (DC) Rev. 1 September 2012 Part No. 4417551 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15

More information

ATL20 ATL30 Automatic transfer switch controller

ATL20 ATL30 Automatic transfer switch controller I 194 GB 07 07 ATL20 ATL30 Automatic transfer switch controller REMOTE CONTROL SOFTWARE MANUAL Summary Introduction... 2 Minimum resources of the PC... 2 Installation... 2 Activation of the PC-ATL connection...

More information

AdminTools. Quick Start Guide. Software for instruments and devices. JSC "Energomera"

AdminTools. Quick Start Guide. Software for instruments and devices. JSC Energomera AdminTools Software for instruments and devices JSC "Energomera" Quick Start Guide 2017 Table of contents 1.PRE-STARTING PROCEDURE... 3 Program installation... 3 Program run... 3 2.PROGRAM INTERFACE...

More information

Smith Meter TM SyberTrol TM Operation

Smith Meter TM SyberTrol TM Operation Flow Computer Smith Meter TM SyberTrol TM Operation Issue/Rev. 0.6 (6/01) Bulletin MN09045 The Most Trusted Name In Measurement Table of Contents Section I - Introduction...1 Product Description...1 How

More information

POWERSOFT THE CONFIGURATOR Instructions for the system configuration and synoptic setup

POWERSOFT THE CONFIGURATOR Instructions for the system configuration and synoptic setup POWERSOFT THE CONFIGURATOR Instructions for the system configuration and synoptic setup Version 09/09 Rel. 2.1.0.4 INDEX 1 THE CONFIGURATOR... 3 1.1 What the configurator is... 4 1.2 The configurator functions...

More information

Intech Micro 2400-A16-SD

Intech Micro 2400-A16-SD Intech Micro 2400-A16-SD Supplementary Manual to the 2400-A16 Installation Guide. 2400-A16-SD Supplementary Manual Index. Description. Page 3 Features. Page 3 Quick Overview of using the 2400-A16-SD Logger.

More information

N2KExtractor. Maretron Data Extraction Software User s Manual

N2KExtractor. Maretron Data Extraction Software User s Manual N2KExtractor Maretron Data Extraction Software User s Manual Revision 3.1.6 Copyright 2017 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10 Phoenix, AZ 85021-7850 http://www.maretron.com

More information

AST2500 ibmc Configuration Guide

AST2500 ibmc Configuration Guide AST2500 ibmc Configuration Guide Version 1.0b Copyright Copyright 2017 MITAC COMPUTING TECHNOLOGY CORPORATION. All rights reserved. No part of this manual may be reproduced or translated without prior

More information

FT2 View Instruction Manual

FT2 View Instruction Manual 399 Reservation Road, Marina, California U.S.A Ph: (831) 384-4300 Fax: (831) 384-4312 www.foxthermalinstruments.com 2006 Fox Themal Instruments, Inc. Introduction: The FT2 View application software is

More information

DataSite Electronic Flow Meter and Remote Terminal Unit

DataSite Electronic Flow Meter and Remote Terminal Unit DataSite Electronic Flow Meter and Remote Terminal Unit Catalog Numbers 1758-FLO301, 1758-FLO302, 1758- RTU201, 1758-RTU202 Software User Manual FRN 1.30 Important User Information Solid state equipment

More information

Publication Information. Trademarks. Contact Information. Support Contact Information Imagine Communications Corp. Proprietary and Confidential.

Publication Information. Trademarks. Contact Information. Support Contact Information Imagine Communications Corp. Proprietary and Confidential. v2.1.6 v2.1.6 Publication Information 2015 Imagine Communications Corp. Proprietary and Confidential. Imagine Communications considers this document and its contents to be proprietary and confidential.

More information

CyberComm Pro Data Acquisition Software Installation & User Guide

CyberComm Pro Data Acquisition Software Installation & User Guide CyberComm Pro 2.2.3 Data Acquisition Software Installation & User Guide ph 1100 and ph 2100 Bench ph and Bench ph/ion Meter Technology Made Easy... 68X090822 rev 1 Aug 2002 2 PREFACE Thank you for selecting

More information

DATA ARCHIVING SOFTWARE V.

DATA ARCHIVING SOFTWARE V. Interscan Corporation. ARC-MAX III - DATA ARCHIVING SOFTWARE V. 2.1.0.9 OPERATION MANUAL 1 Contents 1 Opening the program.... 3 2 Login Window... 3 2 Menu & Toolbar... 4 2.1 Current Data Display... 5 2.2

More information

Robert Shaw Reeltape Model 185A Programmable Serial Interface Card Series 2

Robert Shaw Reeltape Model 185A Programmable Serial Interface Card Series 2 Robert Shaw Reeltape Model 185A Programmable Serial Interface Card Series 2 USER MANUAL Rev. P1.55 April 22, 2011 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc.

More information

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON TROVIS-VIEW 4 Software TROVIS 6661 Operating Instructions Electronics from SAMSON EB 6661 EN Edition January 2015 Definition of signal words DANGER! Hazardous situations which, if not avoided, will result

More information

R7X CONFIGURATOR. (model: R7CON) Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

R7X CONFIGURATOR. (model: R7CON) Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax: R7X CONFIGURATOR (model: R7CON) Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 http://www.m-system.co.jp/ E-mail: info@m-system.co.jp R7CON

More information

ACE Operation Manual

ACE Operation Manual ACE Operation Manual Elecsys Director ACE Operation Manual Product Information Full information about other Elecsys products is available on our website at www.elecsyscorp.com Useful Contact Information

More information

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,

More information

SCADA. SurvalentONE. STC Explorer

SCADA. SurvalentONE. STC Explorer SurvalentONE SCADA SurvalentONE SCADA Survalent SCADA is a software automation solution to provide real-time control and data acquisition for utility operations. Survalent SCADA software includes STC Explorer

More information

IPM650 Intelligent Panel-Mount Display

IPM650 Intelligent Panel-Mount Display Quick Start Guide IPM650 Intelligent Panel-Mount Display Sensor Solutions Source Load Torque Pressure Multi Component Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more

More information

Fox Thermal Instruments, Inc.

Fox Thermal Instruments, Inc. Fox Thermal Instruments, Inc. THERMAL MASS FLOW METER & TEMPERATURE TRANSMITTER FT3 View www.foxthermalinstruments.com 399 Reservation Road Marina, CA. 93933 104845 Rev. D Notice FOX THERMAL INSTRUMENTS

More information

Portable Gas Detector RX-8000 Data Logger Management Program SW-RX-8000(EX) Operating Manual

Portable Gas Detector RX-8000 Data Logger Management Program SW-RX-8000(EX) Operating Manual PT0E-1250 Portable Gas Detector RX-8000 Data Logger Management Program SW-RX-8000(EX) Operating Manual 1 Preface 1-1. Purpose and features of this program 1 Preface The operation procedures and precautions

More information

Using Templates. 5.4 Using Templates

Using Templates. 5.4 Using Templates 5.4 Using Templates Templates are used to create master files for control panel programming data to speed up programming of a new account. A template gives you a very quick and easy way to add a customer

More information

TSXCUSBMBP USB Modbus Plus Communications Adapter User Manual eng

TSXCUSBMBP USB Modbus Plus Communications Adapter User Manual eng TSXCUSBMBP USB Modbus Plus Communications Adapter User Manual 35011984 eng 2 Table of Contents Safety Information.................................... 5 About the Book.......................................7

More information

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4116MCM101(1445) For 4511 devices from ser. no:

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4116MCM101(1445) For 4511 devices from ser. no: 4511 MODBUS RTU Configuration Manual 4116 Universal transmitter 4116MCM101(1445) For 4511 devices from ser. no: 141590001 4116 CONTENTS Introduction... 1 Modbus basics... 1 Modbus RTU... 1 4511 Supported

More information

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Sidewinder Pumps Inc. AC C1D2 Timer/Controller Sidewinder Pumps Inc. AC C1D2 Timer/Controller Page 1 of 14 Rev 4/26/17 Table of Contents 1. Warnings --------------------------------------------------------------------------------------------------

More information

NEC ESMPRO AlertManager User's Guide

NEC ESMPRO AlertManager User's Guide NEC ESMPRO AlertManager User's Guide Chapter 1 General Description Chapter 2 Installation Chapter 3 Setting Chapter 4 Appendix AM_E-UG-W-001-01-004 NEC Corporation 2014 Contents Contents... 2 Notations

More information

BQ & BQ370-01N MODBUS ANALOG INPUT DEVICE USER MANUAL

BQ & BQ370-01N MODBUS ANALOG INPUT DEVICE USER MANUAL BQ370-01 & BQ370-01N MODBUS ANALOG INPUT DEVICE USER MANUAL (Modbus PT Temperature Sensor Reader) Document Version 1.2.0 Content Content 2 About BQ370 Device Family 3 About Device 3 Device Properties 4

More information

RMx621 /FML621. Appendix to the operating manual

RMx621 /FML621. Appendix to the operating manual Appendix to the operating manual RMx621 /FML621 DP-slave module ( PROFIBUS-coupler ) from V2.01.00 Connecting the RMx621 /FML621 to PROFIBUS DP via the RS485 serial interface using the external module

More information

CitectSCADA Batch Tutorial

CitectSCADA Batch Tutorial CitectSCADA Batch Tutorial Version 1.0.8 Citect Pty Ltd 3 Fitzsimmons Lane Gordon NSW 2072 Australia www.citect.com 2 DISCLAIMER Citect Pty. Limited makes no representations or warranties with respect

More information

User Manual JofraCal for JOFRA Temperature, Pressure and Signal Calibrators. Copyright 2004 AMETEK DENMARK A/S

User Manual JofraCal for JOFRA Temperature, Pressure and Signal Calibrators. Copyright 2004 AMETEK DENMARK A/S User Manual JofraCal for JOFRA Temperature, Pressure and Signal Calibrators Copyright 2004 AMETEK DENMARK A/S 2 124918 01 LIST OF CONTENTS Page 1. INTRODUCTION... 11 1.1 General information... 12 1.2 Hardware

More information

Fisher ROC Plus Serial Driver Help Kepware Technologies

Fisher ROC Plus Serial Driver Help Kepware Technologies Fisher ROC Plus Serial Driver Help 2014 Kepware Technologies 2 Table of Contents Table of Contents 2 5 Overview 5 Channel Setup 6 Device Setup 7 Tag Import Settings 7 Address Specification 8 Operator Identification

More information

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON TROVIS-VIEW 4 Software TROVIS 6661 Operating Instructions Electronics from SAMSON EB 6661 EN Edition August 2017 Definition of signal words DANGER! Hazardous situations which, if not avoided, will result

More information

Simplified information where and how you want it.

Simplified information where and how you want it. ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator

More information

InfraSuite Device Master

InfraSuite Device Master Delta Electronics, Inc. InfraSuite Device Master User s Manual Model: EMS4000 Doc. Version: v1.0 Content 1. Introduction... 5 1.1 System Architecture... 5 2. Software Installation... 7 2.1 Presentation

More information

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default

More information

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies Agilent 34826A BenchLink Data Logger for 34980A Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or by any means (including

More information

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer Model: 92000-01 THE STANDARD IN PRECISION MEASUREMENT Table of Contents Introduction... 3 Unpacking... 3 Initial Setup...3

More information

VDG Supervisor. User s manual. A 07/2009 Original publication J.D. GUICHARD C. BERTRAND Ind Date Designation Author Approved

VDG Supervisor. User s manual. A 07/2009 Original publication J.D. GUICHARD C. BERTRAND Ind Date Designation Author Approved ALGADE INSTRUMENTATION DOCUMENT NU-XFAB545-208 ind A VDG Supervisor User s manual A 07/2009 Original publication J.D. GUICHARD C. BERTRAND Ind Date Designation Author Approved 07/2009 ALGADE. All rights

More information

CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500

CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500 CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide CyberScan DO 1500 Bench Dissolved Oxygen Meter Technology Made Easy... 68X292341 Rev.0 01/04 PREFACE Thank you for selecting the CyberScan

More information

Central Management Software. Cam Viewer 3 Lite. User Manual

Central Management Software. Cam Viewer 3 Lite. User Manual Central Management Software Cam Viewer 3 Lite User Manual Version 1.0.0 Table of Contents 1. System Requirement...4 2. Software Installation...5 3. Configuration Wizard...9 3.1 Channel...10 3.1.1 Adding

More information

MotionView Configuration and Programming Software USER S MANUAL

MotionView Configuration and Programming Software USER S MANUAL MotionView Configuration and Programming Software USER S MANUAL IM94MV01C Table of Contents 1 MotionView Software Overview......................................... 3 1.1 Installation and Package Revision.................................................

More information

DISCLAIMER Whilst every effort has been made

DISCLAIMER Whilst every effort has been made PUBLISHED BY Gallagher Group Limited Kahikatea Drive, Private Bag 3026 Hamilton, New Zealand www.gallagherams.com Copyright Gallagher Group Limited 2011. All rights reserved. Patents Pending. MyScale Pro

More information