DistriTon. Enclosures. Steel-plastic RZA Steel-sheet RZB Plastic RZG Plastic IP65 RZI
|
|
- Doris Charles
- 5 years ago
- Views:
Transcription
1 Steel-plastic RZA Steel-sheet RZB Plastic RZG Plastic IP65 RZI Enhanced space Large number of terminals Invented for electricians
2 Main advantages Steel-plastic RZA Enhanced space Large number of terminals Invented for electricians Steel-sheet RZB Plastic RZG Plastic IP65 RZI 2
3 Enhanced space RZA Comfort space at terminal block eceptional distance of terminal blocks from the first row of devices large space for connection of inlet conductors large space for creation of reserves especially at outlet conductors enough space for conductors also after interconnection of the devices by means of the upper busbar Space under the U rails large space for conductors under the U rails at the RZI and RZB enclosures - 10 mm at RZA, RZG - 45 mm at RZI - 50 mm at RZB Space at the sides of the enclosure Spacing of the U rails 135 mm plenty of space for conductors in usual equipment density comfortable work even in case of installation of the maimum number of devices in the row Maimum space between the rows of devices all enclosures offer the most space in their category plenty of space for both interconnection of device and connection of outlet conductors mm at RZA mm at RZG mm at RZI mm at RZB RZB RZG Spacing of the U rails 150 mm Spacing of the U rails mm Spacing of the U rails 150 mm RZI 3
4 Large number of terminals RZA and s for RCCB umber of modules for RCCB RZB terminal block RZG Two terminal blocks RZI terminal block s for RCCBs Two s for RCCBs umber of modules for RCCB umber of modules for RCCB umber of modules for RCCB
5 Invented for electricians RZA Two possibilities of interconnection of devices - interconnection of all devices out of the base - insertion of the frame with devices into the base - interconnection of devices in individual rows out of the base - gradual insertion of interconnected rows of devices into the base - it is not necessary to put conductors under several rails at the same time Variability of the assembly -, s can be placed both up and down - for RCCB can be placed in as many as ten places on the sides of the base - removable front frame with door - depth correction of wrong walling as much as 17 mm RZB Two possibilities of interconnection of devices - interconnection of all devices out of the base - insertion of the frame with devices into the base - interconnection of devices in the first row out of the base - insertion of the first row into the base after the puling through of conductors to the lower rows Variability of the assembly - all terminal blocks can be placed in both upper and lower positions - removable front frame with door - depth correction of wrong walling as much as 25 mm 5
6 PLASTIC ECLOSURES RZG Basic description For building, residential and similar installations. Colour: white (RAL 9003). Door: transparent, non-transparent, opening right/left or upwards. into hollow walls contain mounting anchors for installation into hollow walls. Advantages Large internal area. Large number of terminals. Spacing of the "U" rails mm according to the type of the enclosure. Specifications For mounting devices on "U" rails according to E of width 35 mm with cut-out in 45 mm cover plate. 1 module = 18 mm. Removable frame with "U" rails for flush mounting door. Rigid frame. Wide range. RZG- RZG-Z RZG-Z- -H Installation wall-mounted flush-mounted into hollow walls Test by hot loop ma. 650 C ma. 650 C ma. 850 C Material of front cover self-etinguishing thermoplastic Material of base self-etinguishing thermoplastic Material of door self-etinguishing thermoplastic Standards E Degree of protection IP40 Stage of protection against eternal mechanical shocks IK08 Rated values of the used devices ma. 63 A, AC 230/400 V Rated insulation voltage AC 500 V Device rail "U" rail according to E of width 35 mm Protection class II Power loss dissipated by the surface of the enclosure ΔT = 30 K (difference between internal and eternal temperature) For installation on materials of fire reaction class A1, A2 according to E Wall-mounted RZG- - opening right/left Total umber of rows Door number Terminal blocks s Power Static load of modules modules in a row for RCCBs loss Weight Package (5 6 mm²) [W] [pcs] RZG--1S8 OEZ: RZG--1S14 OEZ: pcs RZG--2S28 OEZ: RZG--3S42 OEZ: RZG--4S56 OEZ: RZG--1T8 OEZ: RZG--1T14 OEZ: pcs RZG--2T28 OEZ: RZG--3T42 OEZ: RZG--4T56 OEZ: on-transparent Wall-mounted RZG- - opening upwards Door Total number of modules umber of rows modules in a row on-transparent RZG--1S4 OEZ: RZG--1S18 OEZ: RZG--2S40 OEZ: RZG--1T4 OEZ: RZG--1T18 OEZ: RZG--2T40 OEZ:40590 Terminal blocks 2 16 mm² mm² 2 16 mm² mm² s for RCCBs (5 6 mm²) Power loss [W] Static load Weight Package [pcs] pcs pcs
7 PLASTIC ECLOSURES RZG Flush-mounted RZG-Z opening right/left Door Total number umber of rows of modules Terminal blocks terminal Power Static load modules in a row blocks for RCCBs loss Weight Package (5 6 mm²) [W] [pcs] RZG-Z-1S8 OEZ: RZG-Z-1S14 OEZ: pcs RZG-Z-2S28 OEZ: RZG-Z-3S42 OEZ: mm² mm² RZG-Z-4S56 OEZ: RZG-Z-1T8 OEZ: RZG-Z-1T14 OEZ: pcs RZG-Z-2T28 OEZ: RZG-Z-3T42 OEZ: RZG-Z-4T56 OEZ: on-transparent Flush-mounted RZG-Z - opening upwards Door on-transparent Total number umber of rows of modules modules in a row RZG-Z-1S4 OEZ: RZG-Z-1S18 OEZ: RZG-Z-2S40 OEZ: RZG-Z-1T4 OEZ: RZG-Z-1T18 OEZ: RZG-Z-2T40 OEZ:40566 Terminal blocks 2 16 mm² mm² 2 16 mm² mm² (216 mm² mm²) terminal blocks for RCCBs (5 6 mm²) Power loss [W] Static load Weight Package [pcs] pcs pcs Into hollow walls RZG-Z-.-H - opening right/left Door Total number umber of rows of modules modules in a row on-transparent Terminal blocks terminal Power Static load blocks for RCCBs loss Weight (5 6 mm²) [W] RZG-Z-1S14-H OEZ: pcs RZG-Z-2S28-H OEZ: RZG-Z-3S42-H OEZ: RZG-Z-4S56-H OEZ: RZG-Z-1T14-H OEZ: pcs RZG-Z-2T28-H OEZ: RZG-Z-3T42-H OEZ: RZG-Z-4T56-H OEZ: Package [pcs] 15
8 PLASTIC ECLOSURES RZG Standard content of package terminal block Wall-mounted RZG- Base - self-etinguishing thermoplastic s for RCCBs - according to the size of the enclosures 1 to 2 units Front cover with removable door "U" rails - each "U" rail is separately attached to the base Labels Single-module d l blind bl d plates - number according to the size of the enclosure ( per a row) Screws for attachment of the cover to the base terminal block Flush-mounted RZG-Z Base - self-etinguishing thermoplastic tic s for RCCBs - according to the size of the enclosures 1 to 2 units Front cover with removable door Removable frame with "U" rails Labels 16 Spacer Single-module blind plates Screws for - number according to the attachment of the size of the enclosure ( per a row) cover to the base Mounting anchors for installation into hollow walls - only for type RZG-Z-...-H
9 PLASTIC ECLOSURES RZG Accessories Product name Description Weight Package [pcs] PD-RG-SB5 OEZ:40593 Terminal block 5 6 mm² PD-RG-SB8 OEZ:40594 Terminal block 2 16 mm² mm² PD-RG-SB14 OEZ:40595 Terminal block 2 16 mm² mm² PD-RG-DSB1-G OEZ:40599 Terminal block holder Single-row, for all terminal blocks PD-RG-SB PD-RG-DSB2-G OEZ:40600 Terminal block holder Two-row, for all terminal blocks PD-RG-SB PD-RGZ81428-DH OEZ:40596 Mounting anchors PD-RGZ42-DH OEZ:40597 Mounting anchors PD-RGZ56-DH OEZ:40598 Mounting anchors Anchors into hollow walls, for RZG-Z, number of modules 8, 14, 28 Anchors into hollow walls, for RZG-Z, number of modules 42 Anchors into hollow walls, for RZG-Z, number of modules Basic eternal dimensions RZG Wall-mounted RZG- Width S Heigh V Depth H RZG RZG RZG RZG RZG RZG RZG RZG H V Flush-mounted RZG-Z, RZG-Z-...-H Width S Heigh V Depth H RZG-Z RZG-Z RZG-Z RZG-Z RZG-Z RZG-Z RZG-Z RZG-Z S H 17
ALPHA SIMBOX Small Distribution Boards
ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional
More information1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings
Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional
More informationALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP
ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type
More informationXL 4000 metal free-standing enclosures and cable compartments
87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL metal free-standing enclosures and CONTENTS PAGE 1. General characteristics...1 2. Range...2 3. Overall dimensions...2 4. Equipment...3
More information02 / The new N/PE Quick-terminals For any type of distribution systems
02 / 2013 The new N/PE Quick-terminals For any type of distribution systems 04 2012 Standardised, future-oriented and flexible The new N/PE Quick-terminals from STRIEBEL & JOHN are designed for the things
More informationIP degrees of protection. Degrees of mechanical shock protection IK conforming to the CEI EN Standard
Definition of IP degree of protection, IK degree of mechanical shock protection and self-extinguishing degree of protection IP degrees of protection 1 st DIGIT: PROTECTION AGAINST SOLID BODIES 2 nd DIGIT:
More informationmodular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security
aesthetics c Elegant and robust design. c Colour easy to integrate in any environment. weatherproof & versatile enclosures multi-functional c Different solutions for: industrial control, electrical distribution,
More informationSmall enclosure golf VF & VS
Small enclosure golf VF & VS The enclosure for flush or surface mounting installation When building or renovating residential buildings, compact solutions are often required for electrical installations.
More informationArgenta W A L L M O U N T I N G M E T A L C A B I N E T S
Argenta W A L L M O U N T I N G M E T A L C A B I N E T S The ARGENTA Series is a group of metal enclosures used to house on the inside electrical or electronic switchgear, controlgear and equipment necessary
More informationConsumer units IP66 >> M135 DOMINO IP66 Series [enclosure] 672.
1 Empty enclosures DOMINO IP66 Series Consumer units IP66 >> M135 INDUSTRY 2 DIN 2 3 4 CONSUMER UNIT Modularity No. Modules Dimension Power IP66 M135 2 MOD. 135x76x102mm 6W 2002 1/24 DOMINO IP66 Series
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine
More informationPragma. Doors reference if necessary. references. In perfect harmony. + customiser
modular surface mounted enclosure Robustness, aesthetic, ergonomics a range of enclosures designed to appeal a harmonious solution. Which enclosure fits you best? Type Rows Modules capacity I(n) number
More informationCABINETS & ENCLOSURES FOR PREPAYMENT METERS
CABINETS & ENCLOSURES FOR PREPAYMENT METERS Solutions designed according to customer need, conceived for every type of prepayment meter: > Meters with keypad data entry terminal > Split meters with remote
More informationThe right solution for every home
Domae Household switchboards The right solution for every home Household guide 2002 Building a New Electric World. Household switchboards Domae The right solution for every home Household guide 2002 Building
More informationElectrical cabinets for server and LAN. 42 Lafer
Lafer@ck Electrical cabinets for server and LAN 42 Lafer Lafer@ck Lafer. Around you Lafer@ck Lafer 43 Lafer@ck Electrical cabinets for server and LAN They are designed for all information systems and data
More informationAC5160 SiPass integrated controller kit
AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one
More informationPan assemblies and installation accessories
Contents Section 10 Pan assemblies and installation accessories SP&N pan assemblies 124 SP&N door and cover 124 TP&N pan assemblies 125 TP&N door and cover 125 Multiclip busbar and Polybloc 126 Comb busbars
More informationLinear Luminaire with LED Series 6012/5
> For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationCCP CABINET PRODUCT RANGE
6300189 CCP Cabinets This document shortly describes all variants of the CCP Cabinet concept. It contains information about visual appearance, main dimensions and major features of each cabinet. The descriptions
More informationALPHA AS NF Universal Modular Distribution Boards
ALPHA AS NF Universal Modular Distribution Boards ALPHA Distribution Boards ALPHA AS universal modular distribution boards provide you with the best framework for currents up to 800 A. The comprehensive
More informationLinear Luminaire with LED Series 6412/5
> For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationMultitronic. Technical data
Multitronic EMC Aluminium enclosure system for MCR technology Integrated guide grooves for PCB s External mounting slots with spring nuts Technical data Material: DIN EN 573 EN AW-AlMgSi Ingress protection:
More informationSwitches and Indicators 84
Switches and Indicators 84 84 Switches and Indicators Index Series 84 Description Page 177 Product Assembly Page 178 Mounting Instruction Page 179 Product Range - pushbuttons for flush mounting - accessories
More informationDIN Rail Mounted Terminals & Accessories
DIN Rail Mounted Terminals & Accessories PAGE PAGE STANDARD CONTA-CONNECT RANGE 253 NEW! CABLECRAFT ABS-S ENCLOSURES 260 DOUBLE & TRIPLE CONTA-CONNECT RANGE 254 NEW! CABLECRAFT ALUMINIUM ENCLOSURES 260
More informationCatalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time
Catalogue G System Pack, wall mount and floor standing enclosures Prisma Plus LV Switchboards Devised to save time General contents Index 2 General presentation 8 Pack 10 17 General presentation Installation
More informationSYSTEM WORLD PRODUCT INFO
SYSTEM WORLD PRODUCT INFO August 208 System case.. System Case Configuration.. Width x depth x height (inches).56 x 0.62 x 3.3 inches Number of System Boxes Material Lid Type Art. No. Empty* ABS Black
More information74 PS range Push-buttons, selectors and indicators Ø 22mm
74 PS range Push-buttons, selectors and indicators Ø 22mm Push-buttons, selectors, indicators and 22mm diameter pre-drilled technopolymer enclosures. Ideal for the creation of signalling and control units
More informationLimanda. Technical data
Polyamide hand held enclosures for data acquisition, MCR and automation engineering 2 sizes: 270 x 248 x 64 mm to 311 x 281 x 72 mm Large fitting area For installations and command devices mobile and stationary
More informationLimanda. Technical data
Polyamide hand held enclosures for data acquisition, MCR and automation engineering 2 sizes - 270 x 248 x 64 mm to 311 x 281 x 72 mm Large fitting area For installations and command devices mobile and
More informationEaton convincing in terms of safety, quality and diversity
Eaton convincing in terms of safety, quality and diversity www.eaton.eu xcomfort - Home game for a safe electrical installation system Powering electrical systems worldwide Buildings Residential Healthcare
More informationSR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories
/ SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationE-KAB N E SERIES WALL- MOUNTED DISTRIBUTION SWITCHBOARDS
E-KAB N E SERIES WALL- MOUNTED DISTRIBUTION SWITCHBOARDS DUVAR T P TES SAT KAB NLER www.eae-et.com.tr EAE Elektroteknik A.S. reserves rights to make changes within this document without prior notice. CONTENTS
More informationDoepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways.
Doepke The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways. Designed to meet BSEN60439-3 these easy to install consumer units accept the
More informationProfile Handles +DQGHO %DWDQJ 6 6.1
Profile Handles.1 Dim. A Dim. B 21 19.5 2,500 12.21.902 30 12.22.909 Dim. A Dim. B 11.5 19.5 2,500 12.20.905.2 Chrome plated Silver coloured anodized E/EV1 Stainless steel coloured Dim. A 300 295 12.2.201
More informationWaterproof Electrical Junction Box Kits Technical Data Sheet
Description Environmentally rated electrical junction box kits, that contain all necessary accessories to complete a straightforward neat wiring installation. Plastic enclosures are equipped with flexible
More informationData Sheets Wiring Components. Fanning Strips. Guide Rings and Holder. Guide Hooks. Spacer Bars. Dummy Plates. Contact. Christian Jaramillo-Arriagada
Data Sheets Wiring Components Fanning Strips Guide Rings and Holder Guide Hooks Spacer Bars Dummy Plates Contact Fax: 0621 683206777 Fanning Strips Wiring Components For a clear connecting arrangement
More informationTP&N DISTRIBUTION BOARD TYPE B RANGE
GROUP Now included in the range: Extension Boxes Metering Kits Surge Suppression and more! TP&N DISTRIBUTION BOARD TYPE B RANGE A comprehensive distribution board range for modern commercial & industrial
More informationIT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationPrisma Plus System P Cubicles up to 4000 A
Low Voltage electric distribution Prisma Plus System P Cubicles up to 4000 A Catalogue 2012 Presentation PD390180_SE.eps IP30/31/55 cubicles b Applications: v indoor cubicles for main or subdistribution
More informationJunction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety
PCe Type CAe Type Compliance Data: ATEX - IEC: ATEX IEC CE Ex ia IIC; Ex ib IIC T6 to T2 Ex td A21 T0 C to T290 C Ex de IIC Operating Temperatures: -40 C to +55 C (CAe) -55 C to +60 C (PCe) 223 ATX Product
More information89SV80/R1200. Mechanical Components. Marshalling rack cubicle with double-sided MTP-Elements. Application. Description. Cubicle
Module Description Procontrol P Mechanical Components Marshalling rack cubicle with double-sided MTP-Elements 1KGD 400 012 E, Edition 01/2010 89SV80/R1200 Application The marshalling rack cubicle has the
More informationADJUSTABLE FLOOR BOXES
ADJUSTABLE FLOOR BOXES TABLE OF CONTENTS Description Applications References Configuration type Installation Technical Data Mechanism compatibility Dimensions Description Floor housings for electrical
More informationVertiv VR Rack 1.0 GENERAL
1.1 SUMMARY Vertiv VR Rack Guide Specifications 1.0 GENERAL This specification defines the mechanical characteristics and requirements for the Vertiv VR Rack. A series of adaptive and scalable electronic
More informationFibox Tempo Junction box NEW. Protection in demanding environments
Junction box NEW Protection in demanding environments IP 65 Tempo Enclosed in seconds! As its name suggests, Tempo doesn t like to hang around. Need an enclosure that s easy on the pocket and installed
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More information1/5 ICONA MONITOR, SBTOP AWARDS ICONA DOOR ENTRY SYSTEMS OVERVIEW 6601W
1/5 OVERVIEW Flush-mounted (in box Art. 6117) or wall-mounted (with bracket Art. 6620) colour monitor with 4.3" 16/9 screen, Full-Duplex hands-free audio and touch-sensitive controls. Allows adjustment
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital Line-voltage independent, all-current sensitive RCCB for fault or additional protection with additional digital features System Monitoring: Preventive
More informationKaedra system PB102271
PB102271 Index General presentation 72 Selection guide 75 Enclosures for sockets 76 Enclosures with interface 77 Enclosures for modular devices 78 Universal enclosures 79 The functional plates 80 Accessories
More informationKNX T-UP. Temperature Sensor. Technical specifications and installation instructions
EN KNX T-UP Temperature Sensor Technical specifications and installation instructions Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70 56 / 93 97-0
More informationIndicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green
22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR
More informationTopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389
opconsole system P System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389 Enclosure: Sheet steel 1.5 mm Door and console cover: Sheet steel, 2.0 mm, all-round foamed-in
More informationBOXES SOLUTIONS BOXES
BOXS BOXS SOLUTIONS - wide range of dimensions: over 40 enclosures with blank door, 9 models with glazed door, enclosures with single blank door, double door with rod system and enclosure with single glazed
More informationReferences. References. Rating (A) Référence
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle
More information1/6 STAINLESS STEEL SBC DIG. 316 SENSE AUDIO ENT.PAN. 3ONE6 DOOR ENTRY SYSTEMS OVERVIEW 3451AS
1/6 OVERVIEW Flush-mounted entrance panel (fitted level with the wall) and 3 mm thick stainless steel plate. Certified as IK08. Complete with 128x64 dot LCD graphic display and 15 buttons integrated into
More informationInsulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals
Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals Technical Data Type: KS 4401 KS 4402 KS 4403 KS 4461 KS 4404 KS 440 KS 4406 Article number * ) : 00636 00637 0063987 00614
More informationJunction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety
CSPe Type Small Version CAe Type Non-Hinged Version CAe Type Hinged Versions Compliance Data: ATEX - IECEx: Zone 1 & 1 & ATEX II GD IECEx CE Ex e II T6 to T Ex td A1 T75 C to T95 C Ex ia IIC; Ex ib IIC
More information1/5 SING.-FMLY KIT W/VANDALCOM & PC INTERCOM VIP SYST. KIT H.264 OVERVIEW 8504H
1/5 OVERVIEW The kit consists of 1 colour audio/video unit art. 4682HKC, 1 module with 1 button art. 3268I/1, 1 flush-mounted box art. 3160/1, 1 frame complete with finishing frame art. 3161/1, 1 power
More informationOrganisational Kitchen Fittings Drawer and Front Extensions
GRASS NOVA PRO TOUCH LATCH SENSO Application: For drawer and front pull-out Material: Steel, plastic, aluminium Finish: Zinc plated, powder coated Opening version: Full extension with self opening mechanism
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Rittal RiLine Compact Power distribution in a confined space Rittal is the leading supplier of reliable power distribution and backup systems for controlgear.
More informationTransparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling
Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling 572 Assembly Application Snapping a cover carrier onto the carrier rail. Application examples: cover
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More informationNew Kit Quadra ViP New Quadra ViP with Mini Audio Handsfree Wi-Fi
New Kit Quadra ViP New Quadra ViP with Mini Audio Handsfree Wi-Fi Passion.Technology.Design. Minimal form is combined with cutting-edge Comelit technology, which can now benefit from all the advantages
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD
More informationBasic Efficiency. NH Fuse-Bases 3-pole. NH Fuse-Bases up to 1500 V. NH Fuse-Bases 1-pole. NH Fuse-Bases, SILAS
Basic Efficiency up to 1500 V 1-pole 3-pole, SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 58 Accessories 60 Technical Data see page 63 NU System The EFEN successfully
More information3RV1 Circuit-Breakers
SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a
More information6. Building Risers M Solutions for Medium Buildings. Description
6. Building Risers 6.2 3M Solutions for Medium Buildings Medium buildings with 5-8 levels / average of about 17 apartments Unbundling OUTSIDE the building or INSIDE the basement Options: - 1 fibre/apartment
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Rittal RiLine Compact Power distribution in a confined space Rittal is the leading supplier of reliable power distribution and backup systems for controlgear.
More informationMounting and Technical Data
Technical Information Mounting and Technical Data / ontent This document describes the technical data, the assembly and selection of cables for the D main distribution and. SM_SM--TI-en-30 Version 3.0
More informationCI/SfB 62 (x) Publication No Quick Fit Floor Service Outlet Boxes & Grommets
CI/SfB 62 (x) Publication No. 010702 Quick Fit Floor Service Outlet Boxes & Grommets Quick fit 2, 3 and 4 compartment floor service outlet boxes Electrak has produced the Quick Fit Floor Service Outlet
More informationDescription of parts Panel mounting Insert mounting without/with Carrier element Plastic housings
- Contents Page Features -... 11.02 Component range -... 11.03 Description of parts... 11.04 Latching parts without/with Strain relief and Panel mounting parts... 11.06 Panel mounting... 11.08 Insert mounting
More informationAMIGO-Distribution Boards for flush mounting
AMIGO-Distribution Boards for flush mounting Flush mounting distribution boards Distribution boards for cavity partition walls Accessories Now also available with screw-less terminals The AMIGO small flush
More informationPower Supply HARTING pcon
HARTING pcon 2060 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)
More informationFlatwall. Aesthetic value and functional integration for home automation
Flatwall Aesthetic value and functional integration for home automation 2 MyHOME FLATWALL Index 2-13 General features 14-33 General rules for installation 34-39 Catalogue MyHOME FLATWALL 240-270 2 MyHOME
More informationTechnical data Consumer units and enclosures dimensions and data 12.4
d w h Isolator controlled surface mounting consumer units EAD1 98 153 94 EAD2/3 154 223 101 EAD4 235 223 120 EAD6 271 223 120 EAD8 307 223 120 EAD12 379 223 120 EAD16 450 223 120 EAD19 450 223 120 Note:
More informationAccessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)
25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The
More informationAerial Façade. Cabinets and borders. Butt and Sleeves Closures for manholes and handholes
6. Building Risers 6. 3M Solutions for Building Risers Single Family Units Skyscrapers Aerial Façade Cabinets and borders Central Telecom POP Butt and Sleeves Closures for manholes and handholes Applications
More informationProtect Circuit Protection
Circuit Protection Product Catalogue 2018 Protect Circuit Protection Deta s new range of domestic Circuit Protection provides a high quality and cost effective solution, perfect for both new build and
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationDatasheet - RSS 36-D-R-ST
14.03.2018-19:30:37h Datasheet - RSS 36-D-R-ST Safety sensors / RSS 36 Thermoplastic enclosure RFID-technology for needs-based protection against tampering Misaligned actuation possible 27 mm x 108.2 mm
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More informationECL Comfort V a.c. and 24 V a.c.
Data sheet ECL Comfort 200 230 V a.c. and 24 V a.c. Application The ECL Comfort 200 electronic controller is pre-programmed for a variety of different applications. Each application has its own card describing
More informationAE-237. Outdoor Enclosure. Installation Guide. Rev IP Sur veillance. Ordering part no.: G AE-237_V01. Document part no.
AE-237 Outdoor Enclosure Installation Guide Ordering part no.: 900026900G AE-237_V01 Rev. 1.1 Document part no.: 625030701G IP Sur veillance CAUTION: TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT REMOVE
More informationPanel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet
Panel Enclosures Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet Construction Enclosure and door are fabricated from code gauge steel (see page 153) All continuous
More informationRESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)
Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) They react to sine-wave residual current (type AC) For protection: against dangerous contact with live parts (I Δn 30
More informationDesk Grommet Number(s) : to 52, to 58, to 63,
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 Desk Grommet Number(s) : 0 540 50 to 52, 0 540 55 to 58, 0 540 60 to 63, CONTENTS PAGES 1.Range 1 to 3 2.Installation 4 to 9 3.Technical
More informationSP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:
DOC0067 Issue 1.2 Reader Wiring InSTRUCTIONS SP1 MP1 WP2 WP1 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes: MP1-EM1 MP1-HT1 MP1-DP1 WP1-EM1 WP1-HT1
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)
DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More informationGFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding
GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding AU1-10R AU1-10P FR1-R EU1-P Cat. No. Drawing Configuration Australian GFCI (RCD) angle plug. trip. 10 ampere 230 volt, 50 Hz. 20 watt maximum. Test
More informationPower Supply HARTING pcon
HARTING pcon 2120 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)
More informationAccessories. Installation channels IKP S. Line-up terminals
Line-up terminals Installation channels IKP S In construction of distribution and switching equipment as well as in construction of electrical wiring there are various systems of either connection or wiring.
More informationVIREO Ceiling with ALX
Square ceiling air diffuser with nozzles for supply air, with plenum box QUICK FACTS Flush design Suitable for VAV-applications Fast and easy installation Sealing ring, standard for spigot Energy efficient
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationPHOENIX CONTACT - 01/2008
Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex
More informationEmergency Luminaire for Fluorescent Lamps Series EXLUX 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More information52 x 50 x light-grey, similar to RAL 7035 CM /1 CM 52/DT /1 CT /1 CT 52/DT /1 M A/B C/D PG A/B C/D
Polycarbonate/ABS housings Protection class: IP66 acc. to EN 60529 Protective insulation: complete protective insulation Burning behaviour PC: UL 94-V2 Burning behaviour ABS: UL 94-HB Toxicity: halogen-free
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More information