Size: px
Start display at page:

Download "Starbreaker Consumer Units & Devices"

Transcription

1 Starbreaker Consumer Units & Devices

2 Acknowledged as one the leading brands in the UK and in British Standard markets around the world, Crabtree offers designers & specifiers a wide range of quality products that caters for a vast array of applications including Commerce, Offices, Education, Hospitals & Health, Hotels & Leisure facilities, in fact wherever quality products are required. Crabtree factories operate a series of internationally recognized standards including ISO9001 for quality, OHSAS for Health & Safety and ISO14001 for Environmental Management. The UK production locations are home to the product management, engineering, design, quality & logistics teams. In the UK Crabtree operates two UKAS accredited Laboratories that carry out R&D and compliance testing on all Crabtree products, these highly accredited facilities ensure that safety, quality & reliability remain consistent with UK & EU legislation regulations & Siemens internal standards, policies and practices. Crabtree products are all designed manufactured and tested in accordance with the recognised product standards, and backed by standard & extended guarantees. Crabtree also operates to recognised standards for product safety & sustainability, Crabtree wiring accessories are RoHS and REACH compliant often in excess of the UK market standards. Crabtrees WEEE compliance process and recycling scheme ensures that the end of product life circumstances are catered for in line with UK & EU Legislation. Recycled materials are used in product packaging, and declared into a recycling scheme locally to control environmental impacts and assure that the maximum level of recycling of materials and use of recycled materials is achieved. As a Siemens company Crabtree also operates a zero harm scheme within all of its manufacturing, logistics & sales facilities, and is proud to have achieved a 5 star Health & Safety rating.

3 CONSUMER UNITS FOR USE IN DOMESTIC HOUSEHOLD PREMISES Contents REGULATIONS 2 CONSUMER UNIT OVER VIEW 4 STARBREAKER CONSUMER UNITS 5 STARBREAKER MCBs & RCBOs 10 STARBREAKER AFDDs 10 DIN DEVICES 11 DIMENSIONS Cannock Commercial Headquarters Home to Sales & Marketing, Supply Chain Management, Finance & Customer Service. 2. Wythenshawe Manufacturing location for domestic & commercial circuit protection, with R&D, UKAS test laboratory ISO9001 production facilities. 3. Hindley Green Production location for wiring accessories & domestic circuit protection with R&D, UKAS test laboratory ISO9001 production, warehouse, distribution & logistics facilities. All Crabtree products comply with the applicable British Standard specification and should be installed by suitably qualified personnel in accordance with the requirements of relevant legislation, regulations (including IET Wiring Regulations) and the accepted practice in the industry. The products listed or described in this publication may be protected by one or more patents, and/or registered designs and/or applications. A full list of patents registered designs and applications may be obtained from the company secretary of Electrium Limited. 1

4 THE WIRING REGULATIONS & DOMESTIC HOUSEHOLD PREMISES NON COMBUSTIBLE CONSUMER UNIT ENCLOSURES BS 7671 (IET Wiring Regulations) prescribe that within domestic household premises consumer units & similar switchgear assemblies must have the enclosures manufactured from noncombustible material e.g. steel, and comply with BS EN The term enclosure includes the box, cover, door, hinges, & fixing screws, all of which must be noncombustible. It can also include the blanks that are used in the cover where there are unused ways. Similar switchgear includes domestic switch fuse units, small consumer units that may be used in detached garages & outbuildings, and other circuit protection assemblies that are used in domestic household premises. ADDITIONAL PROTECTION BY 30mA RCD Several regulations call for additional protection by use of 30mA RCBO / RCD these requirements apply to circuits & accessories in domestic applications including; all lighting circuits, all socket outlets up to & including 32A rating, any mobile equipment for use outdoors up to & including 32A rating, all circuits buried an walls or partitions (at less than 50mm depth) and without earthed mechanical protection, all circuits serving a room with a fixed bath or shower, and all circuits passing through a room with a fixed bath or shower. DIVISION OF THE INSTALLATION Chapter 31 requires the installation to be divided into as many circuits as necessary to avoid danger in the event of a fault. Take account of hazards that may arise from the failure of a single circuit e.g. lighting circuit. Prevent unwanted tripping of RCDs due to PE (non-fault) leakage currents and to allow safe testing & maintenance. UNWANTED TRIPPING OF RCDs Chapter 53 provides guidance on ways to maintain power continuity & avoid unwanted tripping. Designers & installers can use an individual RCBO on each circuit, or ensure that any standing leakage current (from equipment- not from fault conditions) is less than 30% of the RCD trip rating e.g. 30% of 30mA. This is in addition to the requirements of Chapter 31 above. OVERVOLTAGE PROTECTION & SURGE PROTECTION DEVICES Individual dwelling units will require surge protection devices where the value of the installation and all of the equipment connected to it justifies the investment in SPD protection see AFDDs ADDITIONAL PROTECTION AGAINST ELECTRICAL FIRES Chapter 42 deals with protection against thermal effects and includes regulations that deal with devices that provide protection against the risk of electrical fires i.e. RCDs and AFDDs (arc fault detection devices) AFDDs are recommended for the specific purpose of providing additional protection against fires caused by arc faults in 230v AC final circuits. AFDDs are combined with RCBO technology and should be installed at the origin of each circuit that is being protected i.e. in the consumer unit. The combined technology in AFDDs will provide overcurrent protection, short circuit protection, earth leakage protection & additional protection against fires caused by arc faults. METER TAILS FIXINGS & CABLE ENTRIES Chapter 52 incudes requirements for cables (including meter tails) to be installed to avoid any undue strain on conductors and terminations. Where necessary this will mean clipping / fixing meter tails to make sure that stresses & strains are not placed on the tails inadvertently. This is in addition to any other requirements for protecting meter tails at the point of entry into metal consumer unit enclosures. 2 This guide to Starbreaker consumer units is not intended as a substitute for the standards and regulations that should always be used for all types of electrical installation design & installation work.

5 S I 0 INSTALLATIONS IN DOMESTIC HOUSEHOLD PREMISES l Lighting circuits in domestic dwellings must be protected by 30mA RCD l All socket outlets should be protected by 30mA RCD* l All circuits serving or passing through a room with a fixed bath or shower should be protected by one or more 30mA RCDs** l All cables buried beneath the plaster surface of the wall or partition (at less than 50mm) should be protected by 30mA RCDs*** REGULATIONS RELATING TO: EXAMPLES ADDITIONAL PROTECTION Upstairs Sockets Downstairs Sockets * ** series*** and ***** Sockets up to a 32A rating All circuits serving a room containing a fixed bath or shower or circuits not serving but passing through zones 1 or 2 of a room containing a fixed bath or shower Luminaire circuits All circuits buried in a wall or partition at less than 50mm and without mechanical protection l All cables concealed in metal stud partitions (common in new builds) should be protected by 30mA RCDs*** l Installations should be divided up into circuits so as to take account of danger and inconvenience caused by a single fault - e.g. such as a lighting circuit**** l Installations should be designed and arranged so as to prevent unwanted tripping of RCDs**** l Safety services such as smoke alarms should be on independent circuits***** Kitchen Sockets Cooker outlet with integral 13A socket Garage Sockets Plus any other sockets up to 32A rated Shower circuit Lighting circuit Heating circuit Ventilation circuit Plus other circuits Upstairs Lighting Downstairs Lighting Plus other lighting circuits Downstairs Lighting Upstairs Lighting Immersion heater Smoke Alarms (Safety service) Burglar Alarm Plus any other circuits 30mA RCDs Taking into account **** **** 1 The IET onsite guide also recommends that where metal consumer units are installed into TT systems protection from faults arising from the possibility of mains tails becoming loose and making contact with the metal enclosure by incorporating into the installation a 100mA time delayed (S type) RCCB. 2 Furthermore in all cases the mains tails should be protected at the point of entry into the metal enclosure by use of a mains tails gland to protect against the possibility of mechanical damage and or disturbance that could lead to tails becoming loose and making contact with the metal enclosure. ALL INDEPENDENT CIRCUITS Full metal Main Switch unit with RCBOs SOME INDEPENDENT CIRCUITS Full metal High Integrity unit with RCBOs and MCBs 2 2 HALF INDEPENDENT CIRCUITS Full metal Split Load unit with RCBOs and MCBs NO INDEPENDENT CIRCUITS Full metal Dual RCD unit with MCBs TT SYSTEM All independent circuits & 100mA Time Delay RCD * Regulation socket outlets with a rated current not exceeding 32A. ** Regulation Additional protection shall be provided for all circuits serving the location and any circuits not serving but passing through zones 1 or 2 of the location by use of one or more 30mA RCD. *** Regulations in the series, cables concealed in a wall or partition at less than 50mm depth and without earthed mechanical protection e.g. conduit. **** Regulation Every installation shall be divided into circuits as necessary to avoid danger and inconvenience in the event of a fault, take account of danger that may arise from the failure of a single circuit such as a lighting circuit, reduce the possibility of unwanted tripping of RCDs etc. **** Regulation Separate circuits to be provided for parts of the installation that need to be separately controlled in such a way that those circuits are not affected by the failure of other circuits. ***** Regulation Chapter 56 circuits for safety services shall be independent of other circuits. In addition Chapter 51 requires designers/installers to take account of all relevant British Standards and manufacturers instructions. For example BS5839 Part 6 is the British Standard for fire detection and alarm systems in dwellings. It states that power supplies to Grade D smoke alarms should be an independent circuit at the consumer unit, or a separately electrically protected local lighting circuit. Regulation requires that the installed consumer unit achieves IP4X (1mm probe) on the top elevation. All other elevations should be to IP2XC (2.5mm probe) th EDITION WIRING REGULATIONS INCLUDING AMENDMENT No.3 3

6 CONSUMER UNITS FOR USE IN DOMESTIC HOUSEHOLD PREMISES l Fully compatible with Arc Fault Detection Devices (AFDD) contact Crabtree technical for further details l Fully compatible with miniature RCBOs with switched neutral as standard l Full metal enclosure, no exposed plastic parts l Low Smoke & Fume paint l Top hinged self closing, stay shut door & metal hinges l Cable entry knockouts on all sides & large square knockouts on the rear l Mains tails cable entry gland for supplementary insulation similar to Class II level of protection to tails l Non combustible cover blanks for unused ways l Plug in MCB & RCBO 25% fewer connections to make - reducing risk of loose connections MINIATURE RCBO l Add or upgrade circuits without removing busbar - no need to disturb adjacent devices - reducing risk of installation errors 4 l RoHS compliant in excess of UK standards l UKAS certified to BS EN l Finger safe, insulated busbar assembly - provides greater personal protection l Permanent factory fitted, non removable busbar shield - can t be lost or left out l Plug in MCB and RCBOs for instant guaranteed connections l Extra height for added wiring space with single module RCBOs l DIN control devices can be fitted in any position along the DIN rail - without affecting any other devices or busbar connections l High capacity neutral & earth terminals l Factory fitted incoming devices for reduced installation time AFDD

7 MAIN SWITCH UNITS MS Total MCB/ Main Rating RCBO Ways Switch Metal 40A 2* 2 502/2B 63A 2* 2 502/26B 100A /2B 100A /2B 100A /2B 100A /2B 100A /2B *RCBOs are not recommended for use within 502/-- units. 518/2B 515/2963B 515/2883B SPLIT LOAD UNITS 100A SWITCH 63A 30mA RCCB MS Total Main Rating Ways Switch RCCB Metal 100A /2263B 100A /2263B 100A /2363B 100A /2463B 100A /2563B 100A /2363B 100A /2463B 100A /2563B 100A /2663B 100A /2763B 100A /2563B 100A /2663B 100A /2763B 100A /2863B 100A /2963B 100A /2163B Both MCBs and RCBOs may be included for final circuit positions that are not protected by resident RCCBs. SPLIT LOAD UNITS 100A SWITCH 80A 30mA RCCB MS Total Main Rating Ways Switch RCCB Metal 100A /2283B 100A /2383B 100A /2483B 100A /2583B 100A /2383B 100A /2483B 100A /2583B 100A /2683B 100A /2683B 100A /2683B 100A /2783B 100A /2883B 100A /2983B 100A /2183B Both MCBs and RCBOs may be included for final circuit positions that are not protected by resident RCCBs. For consumer unit components see page 12. STARBREAKER ALL METAL CONSUMER UNITS 5

8 513/236565B HIGH INTEGRITY DUAL RCD UNITS RCCB 1 RCCB 2 MS Total Main 63A 63A Rating Ways Switch 30mA 30mA Metal 100A /226363B 100A /226665B 100A /226764B 100A /226863B 100A /236565B 100A /236664B 100A /236763B 100A /246564B 100A /246663B 100A /256464B 100A /256563B 100A /266463B Total RCCB 1 RCCB 2 MS MCB Main 80A 80A Rating Ways Switch 30mA 30mA Metal 100A /218484B 100A /238585B STARBREAKER A LL METAL CONSUMER UNITS 513/ B 518/383B Total RCCB 1 RCCB 2 MS MCB Main 80A 63A Rating Ways Switch 30mA 30mA Metal 100A /238565B 100A /228665B DUAL RCD SPLIT LOAD UNITS Total RCCB 1 RCCB 2 MS MCB Main 63A 63A Rating Ways Switch 30mA 30mA Metal 100A / B 100A / B 100A / B Total RCCB 1 RCCB 2 MS MCB Main 80A 63A Rating Ways Switch 30mA 30mA Metal 100A / B 100A / B 100A / B 100A / B RCD INCOMER UNITS RCCB Total MCB Rating Ways RCCB Metal 40A 30mA /343B 63A 30mA /363B 40A 30mA /343B 80A 30mA /383B 40A 30mA /343B 80A 30mA /383B 80A 30mA /383B 100A 30mA /313B 80A 30mA /383B 100A 30mA /313B 80A 30mA /383B 100A 30mA /313B RCD INCOMER UNIT WITH MCBs RCCB Rating MCB 1 (B) MCB 2 (B) Metal 63A 30mA 2 2 6A 32A 502/363GU 6 For consumer unit components see page 12.

9 516/262B DUAL TARIFF UNITS Main Switch Main Switch Total MCB/ 100A 100A RCBO Ways Tariff 1 Tariff 2 Metal /232B /232B /242B /252B /262B /242B /252B /262B /272B /282B /262B /272B /282B /292B /212B /2112B 513/22623B 526/283B MULTI TARIFF UNITS Total Main Main Main MCB/ Switch Switch Switch RCBO 100A 100A 100A Ways Tariff 1 Tariff 2 Tariff 3 Metal /242124B /282125B /272126B SPLIT LOAD DUAL TARIFF UNITS Main Switch MS Total Main RCCB 100A Rating Ways Switch 63A 30mA Tariff 2 Metal 100A /22623B 100A /25626B 100A /23624B Both MCBs and RCBOs may be included for final circuit positions that are not protected by resident RCCBs. Total Main MCB/ Switch MS RCBO Main RCCB 100A Rating Ways Switch 80A 30mA Tariff 2 Metal 100A /23824B Both MCBs and RCBOs may be included for final circuit positions that are not protected by resident RCCBs. TWO BANK MAIN SWITCH METAL UNITS MS Rating Total Ways LIST No 100A /2B 100A /2B 100A /2B TWO BANK SPLIT LOAD METAL UNITS MS Total Main RCCB Rating Ways Switch 80A 30mA LIST No 100A /283B 100A /283B 100A /283B TWO BANK DUAL RCD SPLIT LOAD METAL UNITS MS Total Main RCCB 1 RCCB 2 Rating Ways Switch 63A 30mA 80A 30mA LIST No 100A /26383B 100A /26383B 100A /26383B STARBREAKER ALL METAL CONSUMER UNITS 7

10 STARBREAKER METAL CASED SKELETON UNITS - 273mm WIDE FIXING CENTRES DESCRIPTION LIST No MAIN SWITCH METAL CASED SKELETON UNITS 7 Way Main Switch Unit 607/2B l 100A DP Main Switch STARBREAKER AMENDMENT 3 SKELETON CONSUMER UNITS 607/2B 610/2B 613/2B STARBREAKER METAL CASED SKELETON UNITS - 320mm WIDE FIXING CENTRES DESCRIPTION LIST No MAIN SWITCH METAL CASED SKELETON UNITS 10 Way Main Switch Unit 610/2B SPLIT LOAD METAL CASED SKELETON UNITS 8 Way Split Load Unit, /2483B HIGH INTEGRITY METAL CASED UNITS 6 Way High Inegrity Unit, /228282B DUAL RCD METAL CASED SKELETON UNITS 6 Way Dual RCD Unit, / B l 100A DP Main Switch l All RCDs have an 80A 30mA rating STARBREAKER METAL CASED SKELETON UNITS - 430mm WIDE FIXING CENTRES DESCRIPTION LIST No MAIN SWITCH METAL CASED SKELETON UNITS 13 Way Main Switch Unit 613/2B SPLIT LOAD METAL CASED SKELETON UNITS 11 Way Split Load Unit, /2583B HIGH INTEGRITY METAL CASED UNITS 9 Way High Integrity Unit, /218484B DUAL RCD METAL CASED SKELETON UNITS 9 Way Dual RCD Unit, / B l 100A DP Main Switch l All RCDs have an 80A 30mA rating 8

11 ASSEMBLED SPINE BACKPLATES MAIN SWITCH Total MCB/ MS Rating RCBO Ways Main Switch LIST No 100A H913/2WB 100A H918/2WB H913/2WB SPLIT LOAD 100A SWITCH 63A 30mA RCCB MS Rating Total Ways Main Switch RCCB LIST No 100A H910/2463WB 100A H910/2563WB 100A H910/2663WB MCBs and RCBOs may be included for final circuit positions not protected by resident RCCBs. SPLIT LOAD 100A SWITCH 80A 30mA RCCB MS Rating Total Ways Main Switch RCCB LIST No 100A H910/2483WB 100A H910/2583WB DUAL RCD SPLIT LOAD Total Main RCCB 1 RCCB 2 MS Rating Ways Switch 80A 30mA 63A 30mA LIST No 100A / WB MCBs and RCBOs may be included for final circuit positions not protected by resident RCCBs. Starbreaker spine backplates (H) accept both MCBs and single module RCBOs. For use in domestic household premises these spine units must be mounted within a non-combustible enclosure. CONSUMER UNIT PATTRESSES ENCLOSURE PATTRASS LEFT/RIGHT TOP/BOTTOM WIDTH DEPTH ENTRY ENTRY 6 Module 16mm MNSPE6670/1NR MNSPE6584/1NR 9 Module 16mm MNSPE6670/2NR MNSPE6584/2NR 12 Module 16mm MNSPE6670/3NR MNSPE6584/3NR 15 Module 16mm MNSPE6670/4NR MNSPE6584/4NR 20 Module 16mm MNSPE6670/5NR MNSPE6584/5NR For use with all metal consumer units. Allows surface cable entry through rear knockouts and automatically maintains enclosure IP rating to comply with BS7671 and BSEN l Cable entry slot may be positioned to suit l Not suitable for use with skeleton units STARBREAKER CONSUMER UNIT PATTRESSES 9

12 MINIATURE CIRCUIT BREAKERS (6kA) B CURVE C CURVE RATING POLES MODULES LIST NO. LIST NO. 6A /B06 61/C06 10A /B10 61/C10 16A /B16 61/C16 20A /B20 61/C20 32A /B32 61/C32 40A /B40 61/C40 50A /B50 61/C50 Not suitable for use in conjunction with AFDD 61/B16 61/B20 61/B40 STARBREAKER C ONSUMER UNIT OUTGOING DEVICES 61/BM /BM /BM /BM40AFD MINIATURE RCBO 6kA (MCB sized 1 module with switched neutral) RCD B CURVE C CURVE RATING RATING POLES MODULES LIST NO. LIST NO. 6A 30mA /BM /CM A 30mA /BM /CM A 30mA /BM /CM A 30mA /BM /CM A 30mA /BM A 30mA /BM /CM A 30mA /BM /CM4030 Type A - Pure AC and pulsating DC sensitivity ARC FAULT DETECTION DEVICES (AFDD) RCD B CURVE C CURVE RATING RATING POLES MODULES LIST NO. LIST NO. 6A 30mA /BM06AFD 61/CM06AFD 10A 30mA /BM10AFD 61/CM10AFD 16A 30mA /BM16AFD 61/CM16AFD 20A 30mA /BM20AFD 61/CM20AFD 25A 30mA /BM25AFD - 32A 30mA /BM32AFD 61/CM32AFD 40A 30mA /BM40AFD 61/CM40AFD Starbreaker arc fault detection devices are only available combined with Miniature RCBOs and so provide the highest levels of protection applied per circuit. For use in main switch controlled units / applications. ACCESSORIES Blanking Plate 443 Blanking Unit (960º) Blanking Plate twist fit MCB Padlocking Device CSB1 CSBC MCBLD 10

13 BELL TRANSFORMER DESCRIPTION MODULES LIST No 12V bell transformer 2 303/B12 l With overload protection. 303/B12 301/TD1 302/TD2 DIGITAL TIMESWITCHES DESCRIPTION MOD LIST No 1 Channel Digital Timeswitch 1 301/TD1 1 Channel Digital Timeswitch 2 302/TD1 2 Channel Digital Timeswitch 2 302/TD2 1 Channel Digital Timeswitch + data key facility 2 402/TD1 2 Channel Digital Timeswitch + data key facility 2 402/TD2 1 Channel Digital Astro Timeswitch + data key facility 2 502/TD1 2 Channel Digital Astro Timeswitch + data key facility 2 502/TD min Staircase Timeswitch 1 301/S10 Software USB/S Data Key 4/5DK Data Key 6DK 301/TQ24 303/TQ7 ANALOGUE TIMERS DESCRIPTION MODULES LIST No 24hr Analogue Quartz 1 301/TQ24 24hr Analogue Quartz 3 303/TQ24 7 Day Analogue Quartz 3 303/TQ7 24hr Analogue Synchronous 1 301/TS11 24hr Analogue Synchronous 3 303/TS24 ACCESSORIES Metal Blanking Plate 543 MCB Padlocking Device MCBLD Universal Adaptor (mains tail gland) MTCG32 See page 16 for modular control devices BELL TRANSFORMERS TIME SWITCHES 11

14 DIMENSIONS l METAL ENCLOSURES STARBREAKER SIZE 4 ENCLOSURE (504/0A) DIMENSIONS A =185mm B =130mm C =104mm 502/26B 502/2B 502/343B 502/363B 502/363GU STARBREAKER SIZE 6 ENCLOSURE (506/0A) DIMENSIONS A =261mm B =188mm C =121mm 504/2B 504/383B 504/343B A STARBREAKER SIZE 9 ENCLOSURE (509/0A) STARBREAKER SIZE 12 ENCLOSURE (512/0A) DIMENSIONS A =261mm B =242mm C =121mm DIMENSIONS A =261mm B =292mm C =121mm C B 504/2263B 505/232B 507/2B 507/383B 507/343B 507/2263B 507/2283B 507/2363B 507/2383B 507/2463B 507/2483B 507/2563B 507/2583B 508/232B 508/242B 508/252B 508/262B 510/2B 510/313B 510/383B STARBREAKER SIZE 15 ENCLOSURE (515/0A) STARBREAKER SIZE 20 ENCLOSURE (520/0A) DIMENSIONS A =261mm B =343mm C =121mm DIMENSIONS A =261mm B =438mm C =121mm 508/22623B 508/226363B 508/ B 509/242124B 510/2363B 510/2383B 510/2463B 510/2483B 510/2563B 510/2583B 510/2663B 510/2683B 510/2763B 511/242B 511/252B 511/262B 511/272B 511/282B 513/2B 513/313B 513/383B 509/218484B 513/226764B 513/226863B 513/23624B 513/236565B 513/236664B 513/236763B 513/23824B 513/246564B 513/246663B 513/25626B 513/256464B 513/256563B 513/ B 513/ B 513/ B 513/266463B 513/ B 513/ B 513/ B 514/272126B 514/282125B 515/2163B 515/2183B 515/2563B 515/2663B 515/2683B 515/2763B 515/2783B 515/2863B 515/2883B 515/2963B 515/2983B 516/2112B 516/212B 516/262B 516/272B 516/282B 516/292B 518/2B 518/313B 518/383B 512/2683B 513/226665B 513/238585B 513/238565B 513/228665B CONSUMER UNIT PATTRESSES l ENCLOSURE PATTRASS LEFT/RIGHT TOP/BOTTOM WIDTH DEPTH ENTRY ENTRY 6 Module 16mm MNSPE6670/1NR MNSPE6584/1NR 9 Module 16mm MNSPE6670/2NR MNSPE6584/2NR 12 Module 16mm MNSPE6670/3NR MNSPE6584/3NR 15 Module 16mm MNSPE6670/4NR MNSPE6584/4NR 20 Module 16mm MNSPE6670/5NR MNSPE6584/5NR For use with Crabtree All Metal consumer units. Allows surface cable entry through rear knockouts and automatically maintains enclosure IP rating to comply with BS7671 and BSEN and the IET onsite guide. DIMENSIONS STARBREAKER TOP/BOTTOM CABLE ENTRY 16 B 255 LEFT/RIGHT CABLE ENTRY B Cable entry slot line up with rear knockouts, the minimum number of knockouts only should be removed for cable entry. Suitable for use with trunking systems

15 DIMENSIONS TWO BANK UNITS STARBREAKER SIZE 24 ENCLOSURE (524/2A) DIMENSIONS A =506mm B =295mm C =121mm 517/26383B 520/283B l STARBREAKER SIZE 30 ENCLOSURE (530/2A) A DIMENSIONS A =506mm B =345mm C =121mm 523/26383B 526/283B STARBREAKER SIZE 40 ENCLOSURE (540/2A) DIMENSIONS A =506mm B =440mm C =121mm 533/26383B 536/283B C B SPINE BACKPLATE ASSEMBLIES (White PVC Cover) B C STARBREAKER 15 MODULE SPINE BACKPLATE UNIT (10W & 13W) DIMENSIONS A =235mm B =335mm C =106mm D =180mm E =319.5mm H910/2463WB H910/2483WB H910/2563WB H910/2583WB H910/2663WB H913/2WB A UNIT FIXING POSITIONS D STARBREAKER 20 MODULE SPINE BACKPLATE UNIT (18W) DIMENSIONS A =235mm B =448mm C =106mm D =180mm E =435mm H918/2WB E STARBREAKER 15 MODULE DRCD (8W) DIMENSIONS A =205mm B =333mm C =106mm D =140mm E =320mm 908/ B STARBREAKER INCOMING DEVICES AND ENCLOSURES ENCLOSURES MODULAR WIDTH ALL METAL 4 504/0A 6 506/0A 9 509/0A /0A /0A /0A /0A /0A /0A FLUSH MOUNTING KIT MODULAR WIDTH ALL METAL 6 506/FLA 9 509/FLA /FLA /FLA /FLA /FLA /FLA /FLA REPLACEMENT COVERS FOR 5 SERIES ENCLOSURES MODULAR WIDTH ALL METAL 6 506/LID 9 509/LID /LID /LID /LID DOUBLE POLE MAIN SWITCH DISCONNECTORS RATING MODULAR WIDTH LIST No 40A 2 40/M12* 63A 2 63/M12* 100A 2 100/MI2* 100A 2 100/2MT** * Used within main switch only and split-load applications ** Used within high integrity and dual RCD applications RESIDUAL CURRENT CIRCUIT BREAKERS RATING MODULAR WIDTH LIST No 40A 30mA 2 340/030 63A 30mA 2 363/030 80A 30mA 2 380/ A 30mA 2 310/030 63A 30mA 3 363/S030* 80A 30mA 3 380/S030* * Dedicated as a split-load RCCB (3 modules) AM 3 UPGRADE / REPLACEMENT COVERS FOR 8 SERIES ENCLOSURES MODULAR WIDTH LIST No 6 806/LID255G 9 809/LID255G /LID255G /LID255G /LID255G D IMENSIONS STARBREAKER 13

16 ELECTRIUM SALES LIMITED A SIEMENS COMPANY Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Cannock WS11 0XE. info@electrium.co.uk Web: UK SALES Telephone: Facsimile: crabtree.sales@electrium.co.uk TECHNICAL Telephone: Facsimile: crabtree.technical@electrium.co.uk EXPORT SALES Telephone: Facsimile: export@electrium.co.uk Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication, specifications and performance data are constantly changing. Latest details can be obtained from Crabtree. Publication No. B2201b or download the APP

Starbreaker Consumer Units for Domestic Household - and other - Premises. Amendment No. 3 BS 7671

Starbreaker Consumer Units for Domestic Household - and other - Premises. Amendment No. 3 BS 7671 Starbreaker Consumer Units for Domestic Household - and other - Premises Amendment No. 3 BS 7671 Acknowledged as one the leading brands in the UK and in British Standard markets around the world, Crabtree

More information

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its Sentry 2 TECHNICAL HOTLINE +44 (0)268 563720 The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its environment. The curved lines and slim-line appearance

More information

Consumer Units IP Rated & Metal Enclosures Devices - MCBs, RCBOs & RCDs. Control Devices & Accessories

Consumer Units IP Rated & Metal Enclosures Devices - MCBs, RCBOs & RCDs. Control Devices & Accessories Consumer Units IP Rated & Metal Enclosures Devices MCBs, RCBOs & RCDs Control Devices & Accessories Modern stylish design with a profile that matches Nexus wiring accessories Quality designed in Flexibility

More information

Protect Circuit Protection

Protect Circuit Protection Circuit Protection Product Catalogue 2018 Protect Circuit Protection Deta s new range of domestic Circuit Protection provides a high quality and cost effective solution, perfect for both new build and

More information

EUSR. An Introduction To BS7671 Amendment 3:2015 DESIGNED FOR featuring Consumer Units for Domestic (Household) Premises as per Reg

EUSR. An Introduction To BS7671 Amendment 3:2015 DESIGNED FOR featuring Consumer Units for Domestic (Household) Premises as per Reg PR EUSR An Introduction To BS7671 Amendment 3:2015 featuring Consumer Units for Domestic (Household) Premises as per Reg. 421.1.201 DESIGNED FOR 2015 Third Amendment Update Significant Change 3rd Amendment

More information

Sentry. Flush mounting versions Flush mounting available for even neater installations.

Sentry. Flush mounting versions Flush mounting available for even neater installations. 271 range introduction features and benefits The range of Consumer Units from MK Electric has been stylishly designed to blend in with its environment. The curved lines and slim-line appearance mean it

More information

Design Range of Consumer Units. Amendment 3 compliant

Design Range of Consumer Units. Amendment 3 compliant Design Range of Consumer Units Amendment 3 compliant March 2015 Designed for safety Designed for installation Designed for aesthetics by Features Comparison Feature Square Knockouts Grommet Strips Front

More information

TP&N DISTRIBUTION BOARD TYPE B RANGE

TP&N DISTRIBUTION BOARD TYPE B RANGE GROUP Now included in the range: Extension Boxes Metering Kits Surge Suppression and more! TP&N DISTRIBUTION BOARD TYPE B RANGE A comprehensive distribution board range for modern commercial & industrial

More information

Defender 1.0. Consumer Units & Devices Domestic Household Premises

Defender 1.0. Consumer Units & Devices Domestic Household Premises Defender 1.0 Consumer Units & Devices Domestic Household Premises Defender 1.0 Contactum Metal Consumer Units for Domestic Hous In January 2015 IET published Amendment 3 of the Wiring Regulations BS7671.

More information

Design Range of Consumer Units. Amendment 3 compliant

Design Range of Consumer Units. Amendment 3 compliant Design Range of Consumer Units Amendment 3 compliant March 2015 Designed for safety Designed for installation Designed for aesthetics by Design 10, 30 The amendment 3 Hager Design ranges include surface

More information

Defender 1.0. Consumer Units & Devices Domestic Household Premises

Defender 1.0. Consumer Units & Devices Domestic Household Premises Defender 1.0 Consumer Units & Devices Domestic Household Premises Defender 1.0 Contactum Metal Consumer Units for Domestic Hous In January 2015 IET published Amendment 3 of the Wiring Regulations BS7671.

More information

RCCB

RCCB 2000 2000 is an advanced modular consumer unit system offering either DP isolator or 2 module DP RCCB (Residual Current Circuit Breaker) incoming control in a split load and inline arrangements. 236 Enclosures

More information

Residential circuit protection buyers guide

Residential circuit protection buyers guide Residential circuit protection buyers guide 2 Contents The range overview... 4 Wiring regulation changes... 6 Domae consumer units... 8 Features and benefits... 9 Quick selector - reference numbers and

More information

Defender. Consumer Units & Devices Domestic Household Premises

Defender. Consumer Units & Devices Domestic Household Premises Defender Consumer Units & Devices Domestic Household Premises Defender Contactum Metal Consumer Units for Domestic Hous In January 2015 IET published Amendment 3 of the Wiring Regulations BS7671. The changes

More information

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways.

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways. Doepke The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways. Designed to meet BSEN60439-3 these easy to install consumer units accept the

More information

NEW Titan II A & B Distribution Boards

NEW Titan II A & B Distribution Boards A Type Board Specification: Powder Coated Epoxy Resin Finish RAL 7035 Designed and built in the UK to BS EN 60439 Maximum busbar rating 125A Degree of protection IP3X to BS EN 60529 Blank gland plates

More information

ßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards

ßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards CHINT EUROPE (UK) LTD Chint Metal Consumer Units ßCompliant with Amendment 3 of BS 7671 : 2008 Regulation 421.1.201 ßBSEN 61439-3 3 to 36 Ways are Standard Specials to Customer Requirements ß 1mm steel

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

Technical data Consumer units and enclosures dimensions and data 12.4

Technical data Consumer units and enclosures dimensions and data 12.4 d w h Isolator controlled surface mounting consumer units EAD1 98 153 94 EAD2/3 154 223 101 EAD4 235 223 120 EAD6 271 223 120 EAD8 307 223 120 EAD12 379 223 120 EAD16 450 223 120 EAD19 450 223 120 Note:

More information

The right solution for every home

The right solution for every home Domae Household switchboards The right solution for every home Household guide 2002 Building a New Electric World. Household switchboards Domae The right solution for every home Household guide 2002 Building

More information

F550e E-learning course Residual current devices basics RCDs Standards. ABB Group April 2, 2009 Slide 1

F550e E-learning course Residual current devices basics RCDs Standards. ABB Group April 2, 2009 Slide 1 F550e E-learning course Residual current devices basics RCDs Standards April 2, 2009 Slide 1 Objectives After completing this module, you will be able to have a clear overview of the residual current device

More information

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip Product Managers and dedicated Business Development Managers are available to assist with all your enquiries. Technical presentations (Forms of Separation, Discrimination etc) available Site response capability

More information

LOADSTAR MCBs AND DISTRIBUTION BOARDS

LOADSTAR MCBs AND DISTRIBUTION BOARDS MCBS AND DISTRIBUTION BOARDS Devices 6kA and 10kA Ranges 6A to 63A Single, Double and Triple Pole Type B, C & D Single and Double module RCBOs 35mm 2 Cable Terminals BS EN 60898 System 125A and 250A TP

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional

More information

Residential Distribution

Residential Distribution Residential Distribution 2 The 18 th Edition Is Here Changes to the wiring regulations with the release of the 18 th Edition of BS 7671:2018 were published in July 2018 and come into effect on 1st January

More information

Consumer Units - Metal

Consumer Units - Metal Circuit Protection Consumer Unit Glands 153 Consumer Units - Insulated 154-156 Consumer Units - Metal 148-151 Contactors 160 DIN Rail Enclosures 159 Fuses - Domestic 161 Fuses - Industrial 162-163 Locking

More information

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

Domae and Qwikline ll. Consumer units

Domae and Qwikline ll. Consumer units Domae and Qwikline ll Consumer units Features and benefits Contents The range overview 3 Domae consumer units 4 Features and benefits 5 Quick selector - reference numbers & descriptions 6 Consumer unit

More information

Dtec Consumer units and

Dtec Consumer units and DTEC Consumer Units Dtec Consumer units and plastic distribution boxes Techna Dtec distribution boxes are available in a variety of stylish and ergonomic designs to suit any application. All our boxes

More information

ALPHA SIMBOX Small Distribution Boards

ALPHA SIMBOX Small Distribution Boards ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional

More information

Sentry Technical. Consumer Units and Enclosures TD255. Standards and approvals. Description. Features. Technical specification

Sentry Technical. Consumer Units and Enclosures TD255. Standards and approvals. Description. Features. Technical specification TD255 Consumer Units and Enclosures Standards and approvals All Sentry consumer units are designed to fully comply with the requirements of BS EN 60439-3. Weatherproof enclosures are designed to fully

More information

Design Range of Consumer Units

Design Range of Consumer Units Design Range of Consumer Units Features Comparison Feature Rectangular Knockouts Grommet Strips Front cover retained screws Cable Clamp Cable Protector Plate Locate & Hold Cover Description Design 10 Design

More information

Design Range of Consumer Units

Design Range of Consumer Units Design Range of Consumer Units Features Comparison Feature Rectangular Knockouts Grommet Strips Front cover retained screws Cable Clamp Cable Protector Plate Locate & Hold Cover Design 10 Design 30 Description

More information

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34 Memshield 3 MCB distribution boards and enclosures 2 Eaton s Memshield 3 MCB distribution boards have evolved through an intimate knowledge and feedback from electrical contractors, consulting engineers

More information

Enclosures & Rotary Switches

Enclosures & Rotary Switches Enclosures & Rotary Switches Circular Box with Cable Glands Junction box with plain press on lid IP44 10 + GW 44001 65mm x 35mm depth 1.00 0.90 GW 44002 80mm x 40mm depth 1.20 1.00 Transparent Cover Boxes

More information

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation ARC FAULT DETECTION DEVICE (AFDD) The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation The S-ARC1 is the new Arc Fault Detection Device (AFDD) with an integrated Miniature Circuit

More information

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its Sentry 2 TECHNICAL HOTLINE +44 (0)268 563720 The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its environment. The curved lines and slim-line appearance

More information

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type

More information

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions RCD Fused Connection Unit Model: RCD10WPV RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV Installation & Operating Instructions General The Timeguard range of RCDs provides protection

More information

Slimline. Technical Hotline

Slimline. Technical Hotline Slimline Deta Slimline has quickly become established as a leading choice for professional installers throughout the country, so much so that it has received the highest accolade being specified by many

More information

FAQ about Drives Technology

FAQ about Drives Technology FAQ about Drives Technology Power supply systems MICROMASTER 4 SINAMICS G120 ID: 25220071 Warranty, liability and support We do not accept any liability for the information contained in this document.

More information

RCDs: everything an electrician should know

RCDs: everything an electrician should know RCDs: everything an electrician should know Electricians do the best they can every day they go to work and we want to leave a job safer than when we found it. But what if despite our best efforts, we

More information

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding AU1-10R AU1-10P FR1-R EU1-P Cat. No. Drawing Configuration Australian GFCI (RCD) angle plug. trip. 10 ampere 230 volt, 50 Hz. 20 watt maximum. Test

More information

DSE201, DSE201 M Compact design with enhanced protection

DSE201, DSE201 M Compact design with enhanced protection DSE20, DSE20 M Compact design with enhanced protection Ultimate safety DSE20 and DSE20 M: the highest level of reliability The P+N electronic residual current circuit-breakers with overcurrent protection

More information

B60 Domestic Voltage Optimisation Unit. Installation Manual

B60 Domestic Voltage Optimisation Unit. Installation Manual Govna B60PVM Voltage Optimisation Unit Govna B60PVM Voltage Optimisation Unit B60 Domestic Voltage Optimisation Unit Web: www.renewableenergyhub.co.uk Email: info@renewableenergyhub.co.uk Phone: 0845 862

More information

Talisman Plus. MCB Distribution Boards & Miniature Circuit Breakers BILL MEANS BUSINESS

Talisman Plus. MCB Distribution Boards & Miniature Circuit Breakers BILL MEANS BUSINESS Distribution Boards & Miniature Circuit Breakers BI MEANS BUSINESS A Type SPN Distribution Boards B Type TPN Distribution Boards A & B Type SPSN Distribution Boards Miniature Circuit Breakers 20V/15V AC

More information

SPM Series Plug-in Surge Protection

SPM Series Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

B60 Domestic Voltage Optimisation Unit

B60 Domestic Voltage Optimisation Unit B60 Domestic Voltage Optimisation Unit Installation Manual V1.2 Nov 2013 1 P a g e PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with the IEE Wiring Regulations,

More information

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data : Miniature Circuit Breakers reliable solutions for protection of installations against over-current phenomenon Advantages for you : Bi-connect terminals for simultaneous termination of bus bar & wires Unique

More information

RCDs RCBOs MCBs Isolating Switches Switchboards

RCDs RCBOs MCBs Isolating Switches Switchboards RCDs RCBOs MCBs Isolating Switches Switchboards 1300 722 275 F: 1300 738 717 RCD 4 Pole 6KA RCDs monitors at all times the current flow and will cut the electrical supply in case of an imbalance. Suitable

More information

Allen-Bradley 1492-RCDA4A40

Allen-Bradley 1492-RCDA4A40 Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps

More information

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

Weathersafe Vision. Installation & Operating Instructions

Weathersafe Vision. Installation & Operating Instructions Weathersafe Vision Installation & Operating Instructions IP66 Products covered by these instructions 1 TGVL01 TGVL02 TGVL03 TGVL05 TGV101N TGV201N TGV104N Single Gang 2-Way Switch [SP] 10AX (Fluorescent

More information

Dorman Smith Loadbank 125 MCCB Panel Boards

Dorman Smith Loadbank 125 MCCB Panel Boards Dorman Smith Loadbank 125 MCCB Panel Boards Section 3 MCCB Panel Boards Loadbank 125 Range (250A and 400A Ratings) Overview Key Features ASTA certified busbars with a short circuit rating of 25kA for 1

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

RiLine Compact The smart power distribution system

RiLine Compact The smart power distribution system RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine

More information

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

17 th Edition (BS 7671:2008) incorporating Amendment No 1

17 th Edition (BS 7671:2008) incorporating Amendment No 1 20 17th Edition 17 th Edition (BS 7671:2008) incorporating Amendment No 1 Installations designed from the 1 st January 2012 are to comply with Amendment number 1. Geoff Cronshaw The first amendment to

More information

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS 2 ENERGY /// TE'S CROMPTON INSTRUMENTS 3 Table of contents I. Tape Wound Measuring and Protection Current MR Series Measuring

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Flatwall. Aesthetic value and functional integration for home automation

Flatwall. Aesthetic value and functional integration for home automation Flatwall Aesthetic value and functional integration for home automation 2 MyHOME FLATWALL Index 2-13 General features 14-33 General rules for installation 34-39 Catalogue MyHOME FLATWALL 240-270 2 MyHOME

More information

SPM Series. Plug-in Surge Protection

SPM Series. Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

Defender B Board. Make The Switch

Defender B Board. Make The Switch Defender B Board Make The Switch Defender B Board 1.2mm Electro Galvanised Sheet Steel Tested to BS EN61439-3 Busbar Short Time Withstand Rating Icw 20kA 0.25s Tested at 35 C Ambient Tin Plated Busbar,

More information

RB60 RANGE. Miniature circuit breakers

RB60 RANGE. Miniature circuit breakers RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection

More information

Prisma Plus System P Cubicles up to 4000 A

Prisma Plus System P Cubicles up to 4000 A Low Voltage electric distribution Prisma Plus System P Cubicles up to 4000 A Catalogue 2012 Presentation PD390180_SE.eps IP30/31/55 cubicles b Applications: v indoor cubicles for main or subdistribution

More information

LoadCentre KQ+ Distribution boards

LoadCentre KQ+ Distribution boards LoadCentre KQ+ Distribution boards Simply safer Square D Serving Your Needs To help electrical contractors Square D provide: An extensive range of easy to install products. Readily available products from

More information

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches NEW P. 4 RX3 MCBs 63 A 4500 & 6000 prong type busbar MCBs, RCDs, add-on modules & accessories P. 9 DX3 RCBOs 63 A 6000 / 10 ka AC, A & Hpi type prong & fork type busbar P. 16 DX3 MCBs 63 A 50 ka mcbs,

More information

Memguard Advantage DISTRIBUTION SYSTEM Product Guide. MCB Single Phase Distribution Boards MCB Three Phase Distribution Boards

Memguard Advantage DISTRIBUTION SYSTEM Product Guide. MCB Single Phase Distribution Boards MCB Three Phase Distribution Boards Memguard Advantage DISTRIBUTION SYSTEM Product Guide MCB Single Phase Distribution Boards MCB Three Phase Distribution Boards 1 Contents and Introduction Contents Page Introduction Contents and Introduction

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

phone fax post web ordering information Please call for the latest pricing or to request a free price list.

phone fax post  web ordering information Please call for the latest pricing or to request a free price list. switchgear everything for those switched on phone fax post email web ordering information Please call for the latest pricing or to request a free price list. opening an account To open a 30 day credit

More information

Smart solutions for electrical distribution in commercial and industrial applications

Smart solutions for electrical distribution in commercial and industrial applications Power distribution components MCB Distribution boards and enclosures MCCB Panelboards Switch and protection devices Industrial switch and fusegear Enclosed motor, heating and lighting control HRC cartridge

More information

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

GSM-X. Communication module. Quick installation guide. Full manual is available on   Firmware version 1.02 gsm-x_sii_en 08/18 GSM-X Communication module Quick installation guide Full manual is available on www.satel.eu Firmware version 1.02 gsm-x_sii_en 08/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk Poland tel. +48 58

More information

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment

More information

PDI Modular Compact Remote Power Panel

PDI Modular Compact Remote Power Panel Guide Specifications (Revision 000, 6/17/2016) 1 GENERAL 1.1 Summary These specifications describe requirements for a remote power panel (RPP) distributing power to sensitive loads. These specifications

More information

CABINETS & ENCLOSURES FOR PREPAYMENT METERS

CABINETS & ENCLOSURES FOR PREPAYMENT METERS CABINETS & ENCLOSURES FOR PREPAYMENT METERS Solutions designed according to customer need, conceived for every type of prepayment meter: > Meters with keypad data entry terminal > Split meters with remote

More information

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit MBP68300 SERIES AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters Modular Construction AC-distribution 3pcs of MCBs Manual bypass switch BPU69000 Dual External static switch

More information

CONTROL PANEL WIRING SPECIFICATIONS

CONTROL PANEL WIRING SPECIFICATIONS CONTROL PANEL WIRING ISSUE STATUS FIRST REV DESCRIPTION DATE 001 1 ST ISSUE 22/04/2014 002 1 ST AMMENDMENT 10/03/2017 003 2 ND AMMENDMENT 08/09/2017 THIS DOCUMENT IS DESIGNED TO COVER ALL APPLICATIONS,

More information

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016 SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016 BY H S W Karunaratne Assistant Director - Engineering Sri Lanka Standards Institution. 1 DEFINITIONS Ac module:

More information

FIBARO SINGLE SWITCH

FIBARO SINGLE SWITCH OPERATING MANUAL EN FIBARO SINGLE SWITCH FGBHS-213 CONTENTS #1: Description and features 3 #2: Supported loads 4 #3: Installation 5 #4: Pairing the accessory 7 #5: Reset 8 v1.1 #6: Functionality 9 #7:

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A. www.moeller.co.uk MCCB Panel Boards 400A / 630A / 800A Product Catalogue and Selection Guide MCCB Panel Boards Moulded Case Circuit Breakers and Accessories XBoard Consumer Units XPole Miniature Circuit

More information

MMLG 01, 02, 03, 04 MMLB01

MMLG 01, 02, 03, 04 MMLB01 MMLG 01, 02, 03, 04 MMLB01 Technical Data Test Blocks and Test Plugs Publication Reference: MMLG_MMLB/EN/TD/B - ALSTOM 2015. All rights reserved. Information contained in this document is indicative only.

More information

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual Installation Manual V2.2 November 2015 PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with the IEE Wiring Regulations, BS7671 (17th Edition or later) and current

More information

Smart solutions for electrical distribution in commercial buildings

Smart solutions for electrical distribution in commercial buildings MEM Sub-Distribution Solutions MCB single phase distribution boards MCB three phase distribution boards MCCB Panelboards Switch and Protection Devices Control and Switching Devices Metering Solutions Smart

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A AUTOMATION MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A GRID Note: The technical manual for this device gives instructions for its installation, commissioning,

More information

AMIGO-Distribution Boards for flush mounting

AMIGO-Distribution Boards for flush mounting AMIGO-Distribution Boards for flush mounting Flush mounting distribution boards Distribution boards for cavity partition walls Accessories Now also available with screw-less terminals The AMIGO small flush

More information

O V E R Y E A R S O F E L E C T R I C A L E X C E L L E N C E

O V E R Y E A R S O F E L E C T R I C A L E X C E L L E N C E Over 130 Years of Electrical Excellence LV Switchboards up to 3200A Panel Boards 400-1250A L2 Compliant Distribution Boards Dorman Smith Switchgear Ltd With over 130 years of experience in switchgear design

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security aesthetics c Elegant and robust design. c Colour easy to integrate in any environment. weatherproof & versatile enclosures multi-functional c Different solutions for: industrial control, electrical distribution,

More information

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE

More information

Smart solutions for electrical distribution in commercial buildings

Smart solutions for electrical distribution in commercial buildings Sub-distribution solutions MEM series MCB single phase distribution boards MCB three phase distribution boards MCCB Panelboards Switch and protection devices Control and switching devices Metering solutions

More information

Energy Division. Crompton Instruments Ebony Current Transformers

Energy Division. Crompton Instruments Ebony Current Transformers Energy Division Crompton Instruments Ebony Current Transformers Moulded Case Current Transformers Ebony Series Measuring and Protection The range of Crompton Instruments Ebony current transformers offers

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Wide range of compact types of RCDs serving as fault-current and additional protection according to UL1053 & IEC/EN 61008 standards,

More information